Danalock V3 Product Manual Z Wave V 0.9.1
2018-11-29
: Z-Wave Danalock V3 Product Manual Z Wave V 0.9.1 Danalock_V3_Product_manual_Z_Wave_V_0.9.1 733 docs
Open the PDF directly: View PDF .
Page Count: 6
Download | ![]() |
Open PDF In Browser | View PDF |
Danalock V3 Product manual The Danalock V3 Z-Wave is a secure electronic door lock that supports the Z-Wave Plus standard, which is compatible with earlier versions of Z-Wave. The Danalock is battery supplied and therefore it is a FLIRS Frequently Listening Routing Slave which conserves battery The Danalock V3 is a security enabled Z-Wave Plus Product. A security enabled Z-Wave controller must be use. The Danalock V3 supports the standard security S0 and the new security standard S2. This manual covers all versions of Danalock V3 Z-Wave. This manual is accompanied by the mounting manually for your specific lock. Z-Wave interoperability The Danalock can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Z-Wave add/inclusion and remove/exclusion • • To add or include the Danalock into a Z-Wave network 1. Set the controller in inclusion mode 2. Push the switch once. 3. Wait 5 seconds. To remove or exclude the Danalock into a Z-Wave network 1. Set the controller in exclusion mode 2. Push the switch once. 3. Wait 5 seconds. Factory Reset The Danalock can be set to factory settings by pushing the switch ten times. Please use this procedure only when the primary controller is missing or otherwise inoperable. Batteries The Danalock uses 4 CR123A batteries. Only use four new batteries from the same manufacturer. Do not mix new and old batteries. The Package contains • Danalock V3 • Batteries (may not be included) • Manual • Adapters (may vary from country to country) If the Danalock is firstly included on a Z-Wave network, the Bluetooth Smart is disabled because of security and to conserve power. To enable Bluetooth Smart enable Configuration byte no. 5. 1 |P a g e Supported Command Classes Command Class Version Not added Non-Secure added Z-Wave Plus Info Transport Service Security 0 Security 2 Association Association Grp Info Battery Configuration Device Reset Locally Door lock Firmware update MD Manufacturer Specific Notification Power level Superversion Version 2 2 1 1 2 1 1 1 1 2 4 2 8 1 1 2 Support Support Support Support Support Support Support Support Securely added Non-secure Secure CC CC Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Node Info Generic Device Class 0x40 GENERIC_TYPE_ENTRY_CONTROL Specific Device Class 0x03 SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK Association CC V2 (secure) Associations Groups Group 1 is Lifeline. All unsolicited reports are sent to the node in Lifeline. The Danalock can send the following commands through Lifeline: ID 1 Name Lifeline Node Count 1 Description Supports the following command classes: • Device Reset Locally: triggered upon reset. • Battery/notification: triggered upon low battery. • Door Lock operation report: triggered upon a change in door lock • Notification: triggered upon a change in door lock Battery CC V1 (secure & unsecure) The Battery Get request can be used to get the status of the battery. To get a useful battery level the motor of the lock should be operated at least once for the lock to sample a meaningful battery level. When battery level is low a battery warning is send to the controller. 2 |P a g e Configuration CC V1 (secure) Z-Wave parameter no. Parameter Name Parameter Default Size value 1 TWIST_ASSIST 2 HOLD_AND_RELEASE (brake and go back) 4 Bytes 0 3 BLOCKED_2_BLOCKED(async) 1 Byte 0 4 BLE_TEMPORARY_ALLOW_TIMER 4 bytes 0 5 BLE_ALWAYS_ALLOWED 1 byte 0 6 1 Byte Autolock 4 bytes 0 0 Description 0 = Disabled, 1=Enabled 0=Disabled, 1-2147483647 (hold seconds) 0 = Disabled, 1=Enabled 0=Disabled, 1-2147483647 (seconds to allow) 0 = Disabled, 1=Enabled 0 = Disabled, 1-2147483647 seconds of delay before autolock enable. Device Reset Locally CC V1 (unsecure) When the Z-Wave module is reset it sends a report to tell the controller it has been reset. The lock is reset by pushing the switch 10 times. Please use this procedure only when the primary controller is missing or otherwise inoperable Door Lock CC V2 (secure) Door Lock Operation is used to lock and unlock the Danalock. See table to see how the Door Lock Mode paramater affects the lock. Door Lock Operation Paramater Secured Unsecured Door Lock Mode 0xFF 0x00-0xEF In a Door Lock Operation Report the Danalock will report: Door Lock Operation Report Value\Door status Unlocked Locked Door Lock Mode 0x00 0xFF Handles 0x11 0x11 Door Condition 0x02 0x05 Lock Timeout Minutes 0xFE 0xFE Lock Timeout Seconds 0xFE 0xFE The Danalock does not use the Door Lock Configuration to adjust settings, the Configuration CC is used instead. The Danalock ignores Door Lock Configuration Set frames and response a Door Lock Configuration Get with: Door Lock Configuration Report Parameter Value Operation Type Constant operation(0x01) Handles Handle 1 enabled (0x11) Lock Timeout Minutes Timeout not supported(0xFE) Lock Timeout Seconds Timeout not supported(0xFE) 3 |P a g e Firmware Update Meta Data CC V4 (secure) The Danalock supports firmware update of the Z-Wave module over the air. The firmware upgrade takes ~30 min with S0 and ~20 min with S2. Firmware ID = 0x0A01. Firmware 0 ID = 0x0000. Manufacture Specific CC V2 (secure & unsecure) Value 0x010E 0x0009 0x0001 Manufacturer ID Product Type ID Product ID Comment Poly-control Danalock V3 Series Lock The Device specific report returns the 6 byte long DMI serial number of the host. Notification CC V8 (secure) The Notification CC is implemented as a push only, which means only pushes notification to the controller. Sequence number is not supported. Supported notifications Notification Type Event Comments Access Control (0x06) Manual Lock Operation (0x01) User Touch button used to lock the door. Manual Unlock Operation (0x02) User Touch button used to unlock the door. RF Lock Operation (0x03) Bluetooth or Z-wave initiated the operation RF Unlock Operation (0x04) Bluetooth or Z-wave initiated the operation Auto Lock Locked Operation(0x09) The Auto Latch time has locked the door. Not used. Auto locks sends (0x01) instead. The lock/unlock operation could not be completed. Lock Jammed (0x0B) Power Level CC V1 (secure & unsecure) Can be used under inclusion to test signal strength from the controller and to the device. Security CC V1 (secure & unsecure) See Z-Wave documentation. 4 |P a g e Security CC V2 (secure & unsecure) The Danalock support S2_ACCESS security class. Superversion V1 (secure) See Z-Wave documentation. Transport Service V2 (secure) See Z-Wave documentation. Version CC V2 (secure) This Command Class is used to get information about which version of the different command classes the Danalock supports and the software version of the Danalock. Version Report Z-Wave Library Type ZW_LIB_SLAVE_ENHANCED(0x03) Z-Wave Protocol Version 0x04 (SDK v6.71.01) Z-Wave Protocol Sub Version 0x3D (SDK v6.71.01) Firmware 0 version Version of the firmware on the Z-Wave module Version Subversion Comments 1 2 First release Firmware 1 version Version of the firmware on the Host. Version Subversion Comments 0 7 First release Hardware version 0x02 Danalock V3 Z-Wave Plus Info CC V2 (secure & unsecure) Z-Wave Plus Info RoleType 0x07 ROLE_TYPE_SLAVE_SLEEPING_LISTENING NodeType 0x00 NODE_TYPE_ZWAVEPLUS_NODE InstallerIconType 0x03 ICON_TYPE_GENERIC_DOOR_LOCK_KEYPAD UserIconType1 0x03 ICON_TYPE_GENERIC_DOOR_LOCK_KEYPAD 5 |P a g e Controller Integration When the Danalock has been included into the network, the controller should: • • Set the Lifeline. Association group 1 Enable Notification for Access Control Test information Configuration Parameters When testing config parameter 4. Be aware that this is a count down, so a set and then a get will not return the same value. Battery Warning To get the lock to send a battery warning the voltage must be low AND the motor must be operated. The lock only measures the battery voltage under load to get the most precise result. By using a 1 A voltage adjustable transformer with approximately 1 meter of wire the following data has been collected. Voltage 12 V 9V 7,5V Battery report value 0x62 (98%) 0x26 (38%) 0x0B (11%) (Battery warning is send) No reports received If no reports are received from the lock it is most likely because the lock is not calibrated and thereby does not no know when the lock is lock or unlock and therefore it does not send reports to the gateway. There are two ways to calibrate the lock. 1. Autocalibration. Turn the Danalock manually until the door is unlocked and leave the door open while calibrating. Lift the handle if needed. Now click 3 times, after 5 seconds the Danalock will calibrate. 2. Manual calibration (start by turn to unlock). Turn the Danalock completely into unlock position, then click twice. Wait 5 seconds until it flashes yellow, then turn the Danalock into locked position and click once. 6 |P a g e
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 6 Language : en-GB Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Microsoft® Word 2016 Creator : Anders Creator Tool : Microsoft® Word 2016 Create Date : 2017:08:14 16:29:05+02:00 Modify Date : 2017:08:14 16:29:05+02:00 Document ID : uuid:44426E3A-2765-4DB1-858E-442A5C6FBE8A Instance ID : uuid:44426E3A-2765-4DB1-858E-442A5C6FBE8A Author : AndersEXIF Metadata provided by EXIF.tools