Danalock V3 Product Manual Z Wave V 0.9.1

2018-11-29

: Z-Wave Danalock V3 Product Manual Z Wave V 0.9.1 Danalock_V3_Product_manual_Z_Wave_V_0.9.1 733 docs

Open the PDF directly: View PDF PDF.
Page Count: 6

1 | P a g e
Danalock V3 Product manual
The Danalock V3 Z-Wave is a secure electronic door lock that supports the Z-Wave Plus standard, which is
compatible with earlier versions of Z-Wave. The Danalock is battery supplied and therefore it is a FLIRS
Frequently Listening Routing Slave which conserves battery The Danalock V3 is a security enabled Z-Wave Plus
Product. A security enabled Z-Wave controller must be use. The Danalock V3 supports the standard security S0
and the new security standard S2. This manual covers all versions of Danalock V3 Z-Wave. This manual is
accompanied by the mounting manually for your specific lock.
Z-Wave interoperability
The Danalock can be included and operated in any Z-Wave network with other Z-Wave certified devices from
other manufacturers and/or other applications. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.
Z-Wave add/inclusion and remove/exclusion
To add or include the Danalock into a Z-Wave network
1. Set the controller in inclusion mode
2. Push the switch once.
3. Wait 5 seconds.
To remove or exclude the Danalock into a Z-Wave network
1. Set the controller in exclusion mode
2. Push the switch once.
3. Wait 5 seconds.
Factory Reset
The Danalock can be set to factory settings by pushing the switch ten times. Please use this procedure only
when the primary controller is missing or otherwise inoperable.
Batteries
The Danalock uses 4 CR123A batteries. Only use four new batteries
from the same manufacturer. Do not mix new and old batteries.
The Package contains
Danalock V3
Batteries (may not be included)
Manual
Adapters (may vary from country to country)
If the Danalock is firstly included on a Z-Wave network, the Bluetooth Smart is disabled because of security and
to conserve power. To enable Bluetooth Smart enable Configuration byte no. 5.
2 | P a g e
Supported Command Classes
Command Class
Version
Not added
Non-Secure
added
Securely added
Non-secure
CC
Secure CC
Z-Wave Plus Info
2
Support
Support
Support
Transport Service
2
Support
Support
Support
Security 0
1
Support
Support
Support
Security 2
1
Support
Support
Support
Association
2
Support
Association Grp Info
1
Support
Battery
1
Support
Configuration
1
Support
Device Reset Locally
1
Support
Door lock
2
Support
Firmware update MD
4
Support
Manufacturer Specific
2
Support
Notification
8
Support
Power level
1
Support
Superversion
1
Support
Version
2
Support
Node Info
0x40 GENERIC_TYPE_ENTRY_CONTROL
0x03 SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK
Association CC V2 (secure)
Associations Groups
Group 1 is Lifeline. All unsolicited reports are sent to the node in Lifeline. The Danalock can send the following
commands through Lifeline:
ID
Name
Node Count
Description
1
Lifeline
1
Supports the following command classes:
Device Reset Locally: triggered upon reset.
Battery/notification: triggered upon low battery.
Door Lock operation report: triggered upon a change in door lock
Notification: triggered upon a change in door lock
Battery CC V1 (secure & unsecure)
The Battery Get request can be used to get the status of the battery. To get a useful battery level the motor of
the lock should be operated at least once for the lock to sample a meaningful battery level. When battery
level is low a battery warning is send to the controller.
3 | P a g e
Configuration CC V1 (secure)
Z-Wave
parameter
no.
Parameter Name
Parameter
Size
Default
value
Description
1
TWIST_ASSIST
1 Byte
0
0 = Disabled, 1=Enabled
2
HOLD_AND_RELEASE (brake and go back)
4 Bytes
0
0=Disabled, 1-2147483647
(hold seconds)
3
BLOCKED_2_BLOCKED(async)
1 Byte
0
0 = Disabled, 1=Enabled
4
BLE_TEMPORARY_ALLOW_TIMER
4 bytes
0
0=Disabled, 1-2147483647
(seconds to allow)
5
BLE_ALWAYS_ALLOWED
1 byte
0
0 = Disabled, 1=Enabled
6
Autolock
4 bytes
0
0 = Disabled, 1-2147483647
seconds of delay before
autolock enable.
Device Reset Locally CC V1 (unsecure)
When the Z-Wave module is reset it sends a report to tell the controller it has been reset. The lock is reset by
pushing the switch 10 times. Please use this procedure only when the primary controller is missing or otherwise
inoperable
Door Lock CC V2 (secure)
Door Lock Operation is used to lock and unlock the Danalock. See table to see how the Door Lock Mode
paramater affects the lock.
Door Lock Operation Paramater
Secured
Unsecured
Door Lock Mode
0xFF
0x00-0xEF
In a Door Lock Operation Report the Danalock will report:
Door Lock Operation Report
Value\Door status
Unlocked
Locked
Door Lock Mode
0x00
0xFF
Handles
0x11
0x11
Door Condition
0x02
0x05
Lock Timeout Minutes
0xFE
0xFE
Lock Timeout Seconds
0xFE
0xFE
The Danalock does not use the Door Lock Configuration to adjust settings, the Configuration CC is used
instead. The Danalock ignores Door Lock Configuration Set frames and response a Door Lock Configuration
Get with:
Door Lock Configuration Report
Parameter
Value
Operation Type
Constant operation(0x01)
Handles
Handle 1 enabled (0x11)
Lock Timeout Minutes
Timeout not supported(0xFE)
Lock Timeout Seconds
Timeout not supported(0xFE)
4 | P a g e
Firmware Update Meta Data CC V4 (secure)
The Danalock supports firmware update of the Z-Wave module over the air.
The firmware upgrade takes ~30 min with S0 and ~20 min with S2.
Firmware ID = 0x0A01.
Firmware 0 ID = 0x0000.
Manufacture Specific CC V2 (secure & unsecure)
Value
Comment
Manufacturer ID
0x010E
Poly-control
Product Type ID
0x0009
Danalock V3 Series
Product ID
0x0001
Lock
The Device specific report returns the 6 byte long DMI serial number of the host.
Notification CC V8 (secure)
The Notification CC is implemented as a push only, which means only pushes notification to the controller.
Sequence number is not supported.
Supported notifications
Notification Type
Event
Comments
Access Control
(0x06)
Manual Lock Operation (0x01)
User Touch button used to lock the door.
Manual Unlock Operation (0x02)
User Touch button used to unlock the door.
RF Lock Operation (0x03)
Bluetooth or Z-wave initiated the operation
RF Unlock Operation (0x04)
Bluetooth or Z-wave initiated the operation
Auto Lock Locked Operation(0x09)
The Auto Latch time has locked the door. Not
used. Auto locks sends (0x01) instead.
Lock Jammed (0x0B)
The lock/unlock operation could not be
completed.
Power Level CC V1 (secure & unsecure)
Can be used under inclusion to test signal strength from the controller and to the device.
Security CC V1 (secure & unsecure)
See Z-Wave documentation.
5 | P a g e
Security CC V2 (secure & unsecure)
The Danalock support S2_ACCESS security class.
Superversion V1 (secure)
See Z-Wave documentation.
Transport Service V2 (secure)
See Z-Wave documentation.
Version CC V2 (secure)
This Command Class is used to get information about which version of the different command classes
the Danalock supports and the software version of the Danalock.
Version Report
Z-Wave Library Type
ZW_LIB_SLAVE_ENHANCED(0x03)
Z-Wave Protocol Version
0x04 (SDK v6.71.01)
Z-Wave Protocol Sub Version
0x3D (SDK v6.71.01)
Firmware 0 version
Version of the firmware on the Z-Wave module
Version
Subversion
Comments
1
2
First release
Firmware 1 version
Version of the firmware on the Host.
Version
Subversion
Comments
0
7
First release
Hardware version
0x02
Danalock V3
Z-Wave Plus Info CC V2 (secure & unsecure)
Z-Wave Plus Info
RoleType
0x07 ROLE_TYPE_SLAVE_SLEEPING_LISTENING
NodeType
0x00 NODE_TYPE_ZWAVEPLUS_NODE
InstallerIconType
0x03 ICON_TYPE_GENERIC_DOOR_LOCK_KEYPAD
UserIconType1
0x03 ICON_TYPE_GENERIC_DOOR_LOCK_KEYPAD
6 | P a g e
Controller Integration
When the Danalock has been included into the network, the controller should:
Set the Lifeline. Association group 1
Enable Notification for Access Control
Test information
Configuration Parameters
When testing config parameter 4. Be aware that this is a count down, so a set and then a get will not return the
same value.
Battery Warning
To get the lock to send a battery warning the voltage must be low AND the motor must be operated. The lock
only measures the battery voltage under load to get the most precise result. By using a 1 A voltage adjustable
transformer with approximately 1 meter of wire the following data has been collected.
Voltage
Battery report value
12 V
0x62 (98%)
9V
0x26 (38%)
7,5V
0x0B (11%) (Battery warning is send)
No reports received
If no reports are received from the lock it is most likely because the lock is not calibrated and thereby does not
no know when the lock is lock or unlock and therefore it does not send reports to the gateway. There are two
ways to calibrate the lock.
1. Autocalibration. Turn the Danalock manually until the door is unlocked and leave the door open while
calibrating. Lift the handle if needed. Now click 3 times, after 5 seconds the Danalock will calibrate.
2. Manual calibration (start by turn to unlock). Turn the Danalock completely into unlock position, then
click twice. Wait 5 seconds until it flashes yellow, then turn the Danalock into locked position and click
once.

Navigation menu