ZTE AC8700 CDMA 2000 EV-DO Wireless DATA Terminal User Manual

ZTE Corporation CDMA 2000 EV-DO Wireless DATA Terminal

Users Manual

  CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcnCDMA2000 1X EV-DO Wireless Data Terminal User Guide This User Guide applies to Wireless Data Terminal of MG478 and AC8700.
  CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcnCopyright Statement Copyright © 2006 by ZTE Corporation   All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without the prior written permission of ZTE Corporation. ZTE Corporation reserves the right to make modifications on print errors or update specifications in this manual without prior notice. V1.0, August, 2006
  CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcnTable of Contents 1. Introduction.............................................................................................................................1 2. Specification ...........................................................................................................................1 3. Precautions..............................................................................................................................1 4. Appearance .............................................................................................................................2 4.1 Introduction.........................................................................................................................2 4.2 Insert R-UIM Card ..............................................................................................................3 5.  Install and Uninstall................................................................................................................4 5.1Windows 2000 ...................................................................................................................55.1.1 Install........................................................................................................................5 5.1.2 Uninstall...................................................................................................................9 5.2Windows XP ....................................................................................................................105.2.1 Install......................................................................................................................10 5.2.2 Uninstall.................................................................................................................14 6. Run the Application ..............................................................................................................15 7. Connect/Disconnect..............................................................................................................16 8. Connection Records..............................................................................................................17 9. Setting...................................................................................................................................18 10. Help ......................................................................................................................................20 11. Connect to the Website .........................................................................................................20 12. Trouble-shooting...................................................................................................................21
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn1. IntroductionThank you for choosing MG478/AC8700 CDMA2000 1X EV-DO Wireless Data Terminal (hereinafter referred to as Data Terminal) of ZTE Corporation.   The Data Terminal equips with a standard USB interface and supports both CDMA2000 1X EV-DO and CDMA2000 1X network. In the area where there is signal, it allows you to go surfing on the Internet, browse the web pages, and send & receive Emails 2. Specification             Model Parameter MG478 AC8700Transmitting Frequency 452.625-456.850MHz 824-849MHzReceiving Frequency 462.625-466.850MHz 869-894MHzStability Fc±300Hz Dimensions (L×W×H)80 mm ×36 mm×12.8mmWeight 38.7g Data Rate  Max. down-link transmission rate: 2.4Mbps, Max. up-link transmission rate: 153Kbps Current 5V˄using USB interface supply˅Current Consumption  Sleep: 5mA   Max.: 480mA Transmitting Power 224mW3. Precautions¾Please don’t use the product near flammable or explosive materials because it might cause failure or fire.   ¾Keep the product away from high temperature, humidity, or dust because it might cause failure.¾Avoid shock, cast or impact. Please keep the product well when you don’t use it. ¾Do not dismantle or disassemble the product at will or revolve the antenna frequently. Our company will not provide warranty service for the damage caused by abnormal operations. ¾Don’t use the product near the place where is weak signal or high-precision electronic device because the magnetic interference might cause the misoperation of electronic device or other problems.  ¾Please don’t insert or pull out the card with great force to avoid damaging the interface.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn4. Appearance4.1 Introduction Top View             Rear View               LED status descriptions: Network Registered  There is service or searching the network LED Insert the data terminalEV-DO  1X EV-DO  1XYellow  ON  OFF  Slow Flash OFF  Quick Flash Green  ON  Slow Flash OFF  Quick Flash  OFF USB Interface HostTap AntennaLEDR-UIM Card Cover
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn4.2 Insert R-UIM Card Note: If your data terminal doesn’t need R-UIM card, please skip this section. 1. Pull out the tap 2. Take out the R-UIM card cover in the   direction indicated by the arrow                  3. Insert R-UIM card as below figure                               4. Push back R-UIM card cover in the direction indicated by the arrow
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn5. Install and Uninstall System Requirements: The Data Terminal supports the following operating system: ¾Windows 2000 ¾Windows XP PC minimum configurations: CPU Pentium-II/233MHz USB interface    2.0 (USB1.0 and 1.1 compatibleOptical Drive    CD-ROM (for installation only)   Memory   64 MB  Disk Space    30 MB (used for installation of application)
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn5.1Windows 2000 5.1.1 Install Note:Do not insert the Data Terminal before installation. 1ǃFind “Setup.exe” firstly in Data Terminal CD-ROM, double-click it to display the Welcome picture, and then click “Next”; 2ǃSelect the location where you want the program to be installed, and then click “Next”;
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn3ǃSelect Start Menu folder, and then click “Next”; 4ǃWhen you see the window below, please click “Install”; 5ǃPlease wait for installation.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn6ǃPlease insert the Data Terminal into USB interface if the system prompts you to insert the hardware (If it has been inserted, please unplug it and insert again.)7ǃThe system shall find the new hardware and install the driver automatically. Just wait a minute;
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn8ǃThe driver is installed successfully. Pleas click “OK”; 9ǃClick “Finish” to close the last screen of the wizard. Now you can start the application for Data Terminal.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn5.1.2 Uninstall 1ǃSelect Start -> Programs -> ZTE EV-DO -> Uninstall ZTE EV-DO. Click “Uninstall ZTE EV-DO”, and you will be asked if you want to remove the program. Click “Yes”; 2ǃPlease wait; 3ǃClick “OK” when un-installation is completed;
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn5.2Windows XP 5.2.1 Install Note:Do not insert the Data Terminal before installation. 1ǃFind “Setup.exe” firstly in the Data Terminal CD-ROM, double-click it to display the Welcome picture, and then click “Next”; 2ǃSelect the location where you want the program to be installed, and then click “Next”;
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn3ǃSelect Start Menu folder, and then click “Next”; 4ǃWhen you see the window below, please click “Install”; 5ǃPlease wait for installation. This process will take a few minute;
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn6ǃPlease insert the Data Terminal into USB interface if the system prompts you to insert the hardware (If it has been inserted, please unplug it and insert again.)7ǃThe system shall find the new hardware and install the driver automatically. Just wait a minute.(Please ignore the prompt during the installation, such as “USB device not recognized” or “Your hardware might not be able to work normally because there is an error during the hardware installation.”)
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn8ǃThe driver is installed successfully. Pleas click “OK”; 9ǃClick “Finish” to close the last screen of the wizard. Now you can start the application for data terminal
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn5.2.2 Uninstall 1ǃSelect Start -> Programs -> ZTE EV-DO -> Uninstall ZTE EV-DO. Click “Uninstall ZTE EV-DO”, and you will be asked if you want to remove the program. Click “Yes”; 2ǃPlease wait; 3ǃClick “OK” when un-installation is completed.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn6. Run the Application After the application is installed successfully, the application icon    will appear on your desktop. Double-click this icon or select from Start -> Programs -> ZTE EV-DO -> ZTE EV-DO. Run the application to display the following user interface. The icons on the interface are used to access the function, which indicate as below: Connect/Disconnect Open URL Connection Records SettingHelpStatus Bar: EV-DO Indication 1X Indication Signal strength indication. The more bars, the stronger signals CDMA network unavailable Network Connection Sleep mode In Roaming No R-UIM card inserted R-UIM card inserted
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn7. Connect/DisconnectConnectClick    icon to set the relevant parameters. For details, please refer to Chapter 9 “Setting” for details; Click    icon at the left-up corner of the interface; After connecting to Internet, the current network information will appear on the interface. Double-click any place in the display area to view the connection records. DisconnectAfter connecting to Internet, click the rotating icon    at the left-up corner of the interface.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn8. Connection Records Click   icon to view connection records. Connection records save the previous relevant information including Start at, Duration and Transmit bytes, which help you know the status easily. By switching among “List”, “Monthly” and “Statistic”, you could inquire the records every time, by month or by time. Note:The relevant information contained in connection records are just for user’s reference rather than the charging basis. Delete Connection Records Click “Delete” button to delete the records you have selected on the interface. Clear Connection Records Click “Clear” button to delete all the records.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn9. SettingNetwork Connection Setting Click   icon to set up the relevant parameters. After the setting, click “Apply” button to save the settings on the current interface. Click “Default” button and then “Apply” button to restore the settings on the current interface to factory default.   Note:The default network setup parameters are as below. Different regions may have different network setup parameters, so please consult your local telecom operator. Phone: #777 User: card Password: card
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcnOther Setting: Click “Options” to switch the interface, and you could set URL and select the skin, language, etc. After that, click “Apply” button to save the settings on the current interface .   Click “Default” button and then “Apply” button to restore the settings on the current interface to factory default.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn10. Help Click    button to view the help file.   Click “Help” button to view the relevant help file; click “Online service” to enter our company’s website. You could view the software and its version information under “About”. 11.  Connect to the Website Click    button to directly connect the website you set. For details on the website setting, please refer to Chapter 9 “Setting”.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcn12. Trouble-shooting After the installation, go to device manager and find “ZTE Status Interface 3197” under “Modem” and “ZTE USB Modem 3197” under “Port”. If they are not found, please remove the software and reinstall.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcnCommon Failures Table: Failures Causes SolutionsError occurs when running setup.exe file.  The setup file may be damaged. Please download the program on our website WWW.ZTEIT.COMand reinstall it. Directly run the software before the Data Terminal is plugged in. Close the software, plug in the Data Terminal and run it again. Open port failed.  The port is occupied by other applications, such as “Hyper terminal”, or the software is already run. Close relevant software and run the software again. R-UIM card is not inserted.  Insert R-UIM card. R-UIM card isnÿt inserted properly. Sometimes the front side and back side are confused. Please refer to section 4.2. Properly insert R-UIM card. No R-UIM card. R-UIM card is damaged. Validate by using a CDMA terminal.   Replace R-UIM card. Antenna is not connected to the Access Box.Insert the antenna into the Data Terminal. Out of the network service area.  Make sure it is in the CDMA network service area. No signal indicated. The antenna or RF component is damaged.Replace relevant damaged parts. Wrong setting of parameters (Phone, User, Password) Correct the parameter settings. Consult your service provider for details. Not enough money in R-UIM card.  Consult  your  service  provider  for details. Dialing failed Network congestion or failure.  Try again later. The Data Terminal is being connected. (It usually occurs when the Internet connection is immediately made after the call is dialed) Reconnect.Internet connection failure. Poor network signal.  View signal  strength indication and check if the antenna is properly inserted.
    CDMA2000 1X EV-DO Wireless Data Terminal User Guide ZTE Corporation  http//wwwztecomcnIf the problems cannot be solved after the above handling, please call 86-755-2601555 or feed back your information directly by sending emails to zte_mobile@zte.com.cn for customer service. We will reply to you as soon as possible and provide you with high quality after-sales services.*SAR InformationThe SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types AC8700(FCC ID: Q78-AC8700) has also been tested against this SAR limit. The highest SAR value reportedunder this standard during product certification for use when properly worn on the body is 0.271 W/kg.

Navigation menu