ZTE ME3000V2 GSM DUAL BAND GPRS WIRELESS DATA TERMINAL User Manual Q78 ME3000V2
ZTE Corporation GSM DUAL BAND GPRS WIRELESS DATA TERMINAL Q78 ME3000V2
ZTE >
Users Manual
Operation Description ME3000V2 Operation Description Version:V1.0 ZTE CORPORTION Operation Description Table of Contents Mechanical Interface ...................................................................................................................... 3 1.1 1.2 Electrical Interface ......................................................................................................................... 4 2.1 Antenna Installation ................................................................................................................................... 7 Antenna Pad ............................................................................................................................................... 7 Antenna connector ..................................................................................................................................... 7 RF Interface ................................................................................................................................... 9 5.1 5.2 Power and Reset ......................................................................................................................................... 6 3.1.1 Power supply ..................................................................................................................................... 6 3.1.2 Power on ............................................................................................................................................ 6 3.1.3 Power off ........................................................................................................................................... 6 3.1.4 Reset .................................................................................................................................................. 6 Antenna Interface ........................................................................................................................... 7 4.1 4.2 4.3 Pin Assignments ......................................................................................................................................... 4 Power Management ....................................................................................................................... 6 3.1 Physical Features ........................................................................................................................................ 3 Mechanical size .......................................................................................................................................... 3 Overview .................................................................................................................................................... 9 Antenna Subsystem .................................................................................................................................... 9 5.2.1 Antenna Specifications .................................................................................................................... 10 5.2.2 Cable Loss ....................................................................................................................................... 10 5.2.3 Antenna Gain Minimum Requirements ........................................................................................... 10 5.2.4 Antenna Gain Maximum Requirements .......................................................................................... 10 5.2.5 Antenna Matching ........................................................................................................................... 10 5.2.6 PCB Design Considerations............................................................................................................. 10 5.2.7 Other Precautions............................................................................................................................. 10 5.2.8 Grounding .........................................................................................................................................11 Test Capabilities ........................................................................................................................... 12 6.1 6.2 Test Description........................................................................................................................................ 12 GSM Test Equipment and Tools............................................................................................................... 13 6.2.1 GSM RF Rx Specification ............................................................................................................... 14 6.2.2 GSM RF Tx Specification: .............................................................................................................. 14 6.2.3 High Temperature Operation Test .................................................................................................... 14 6.2.4 Low Temperature Operation Test .................................................................................................... 14 6.2.5 High Temperature Storage Test ....................................................................................................... 14 6.2.6 Low Temperature Storage Test........................................................................................................ 15 6.2.7 High Temperature High Humidity Operation Test .......................................................................... 15 6.2.8 Temperature Concussion Test ......................................................................................................... 15 6.2.9 ESD Immunity Test ......................................................................................................................... 15 6.2.10 Radiated Emissions Test .................................................................................................................. 15 Operation Description 1 Mechanical Interface 1.1 Physical Features Dimensions & Weight Operational Temperature Range Storage Temperature Range ROHS Antenna Connectors Power Supply Length: Width: Thickness: Weight: 44.5 mm 28.5 mm 8.25 mm 8g -20℃ to +65℃ -40℃ to +80℃ Yes 50-Ohm ANT connectors for GSM Two kinds of inputs: 1.external power supply (+4.75V~ +5.25V, typical value +5V) 2. battery power supply (+3.3V~ +4.2V, typical) 1.2 Mechanical size Figure 1-1: ME3000V2 T-viewgraph Operation Description 2 Electrical Interface 2.1 Pin Assignments Figure 2-1 ME3000V2 Module interface ME3000V2 map Table 2-1 ME3000V2 Module 40-pin Electrical Interface Pin Signeal Name Signal Type Inpu t/Out Function put Min Typ Max Uni Comments SIM-CLK Digital SIM clock 2.5 2.8 3.3 2.8VLevel SIM-VCC Power SIM power supply 2.5 2.8 3.3 2.8VLevel 30 11 13 30 28 22 SIM-DATA SIM-RST SIG_LED RXD2 RXD TXD2 TXD SIG_LED SMS_LED V_MAIN Digital Digital Digital Digital Digital Digital Digital Digital Digital Power I/O SIM data SIM reset LED control COM Port COM Port COM Port COM Port LED control LED control Main power 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3.3 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 3.7 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 4.25 2.8VLevel 2.8VLevel 2.8VLevel 2.8VLevel 2.8VLevel 2.8VLevel 2.8VLevel 2.8VLevel 2.8VLevel Operation Description 25 V_MSM Power 15 RI Digital 17 14 16 /DSR /RTS /DTR Digital Digital Digital RTS2 Digital 12 /CTS External power supply 2.5 2.8 3.3 2.5 2.8 3.3 COM Port COM Port COM Port 3.3 3.3 4.75 3.8 3.8 4.2 4.2 5.25 COM Port 3.0 3.8 4.25 Digital COM Port 2.5 2.8 3.3 CTS2 Digital COM Port 2.5 2.8 3.3 18 DCD Digital COM Port 2.5 2.8 3.3 10 /RESET Digital System reset 2.5 2.8 3.3 26 ON/OFF Digital Power on/off key control 2.5 2.8 3.3 35 EAR_ANT_D ET Analog EARPHONE MIC KEY 36 EAR_DET Digital 37 39 38 40 MIC_1N MIC_1P MIC_2P MIC_2N Analog Analog Analog Analog AI AI AI AI 32 SPK_1N Analog AO 34 SPK_1P Analog AO 33 SPK_2P Analog AO EARPHONE insert detect Mic inputMic input+ Mic input+ Mic inputSpeaker outputSpeaker outputSpeaker output- LED ON as the level is high. Headset MIC Earphone MIC Headset Receiver Earphone Receiver Operation Description 3 Power Management 3.1 Power and Reset 3.1.1 Power supply The module could work under two power modes: 1. Charger; 2 Battery. When powered by the charger, you could perform constant current charge, constant voltage charge and trickle current charge. Normally, trickle current charge starts when the voltage is lower than 3.2V, constant current charge starts as the voltage is between 3.2V and 4.0V; and constant voltage charge starts when the voltage reaches 4.0V. As the blackout happens, the battery would be immediately used. See table 4-1 for the module’s input voltage characteristics. If the input voltage is not in the range, it must be converted to the voltage below: Table4-1 Voltage Characteristics 1. External power supply Status Max. voltage Power supply +5.25 VDC Typical voltage +5.0VDC Min. voltage +4.75 VDC 2. Battery(currently the software supports Li battery) Status Power supply 3.1.2 Max. voltage +4.25 VDC Typical voltage +3.8 VDC Min. voltage +3.3 VDC Power on The module is under power-off status after it’s normally powered on. To turn on the module, provide a 1500-2000mS low level pulse to ON/OFF pin when the module is OFF. 3.1.3 Power off To turn off the module, provide a 1500-2000mS low level pulse to ON/OFF pin when the module is ON. 3.1.4 Reset Use the above method to firstly “Power off” and then “Power on”, and by doing so the module could be reset. ME3000V2 module does not lead the reset pin. Operation Description 4 Antenna Interface The RF interface of the ME3000V2 Module has an impedance of 50 . The module is capable of sustaining a total mismatch at the antenna connector or pad without any damage, even when transmitting at maximum RF power. The external antenna must be matched properly to achieve best performance regarding radiated power, DC-power consumption, modulation accuracy and harmonic suppression. Antenna matching networks are not included on the ME3000V2 Module PCB and should be placed in the host application. Regarding the return loss, the Module provides the following values in the active band: Table 4-1 Return Loss in the Active Band State of Module Return Loss of Module Recommended Return Loss of Application Receive Transmit ≥ 8dB not applicable ≥ 12dB ≥ 12dB The connection of the antenna or other equipment must be de coupled from DC voltage. This is necessary because the antenna connector is DC coupled to ground via an inductor for ESD protection. 4.1 Antenna Installation To suit the physical design of individual applications, the ME3000V2 offers two alternative approached to connecting the antenna: ■ Recommended approach: MM9329-2700B antenna connector manufactured by MURATA assembled on the component side of the PCB (top view on Module). See Section 4.3 for details. ■ Antenna pad and grounding plane placed on the bottom side. See Section 4.2 for details. The MM9329-2700B connector has been chosen as antenna reference point (ARP) for the ZTEMT reference equipment submitted to type approve the ME3000V2 Module. All RF data specified throughout this manual are related to the ARP. For compliance with the test results of the ZTEMT type approval you are advised to give priority to the connector, rather than using the antenna pad. Note: Both solutions can be applied alternatively. This means,if the antenna is connected to the pad, then the connector on the Module must be left empty,and when the antenna is connected to the Module connector, the pad is useless, 4.2 Antenna Pad The antenna pad of the module is soldered to the board on the customer design to connect with RF line. For proper grounding connect the RF line to the ground plane on the bottom of the MG2636 Module which must be connected to the ground plane of the application. Consider that according to GSM recommendations as 50Ω connector is mandatory for type approval measurements. It must be ensured that the RF line which is connected to antenna pad should be controlled on 50Ω. Notes on soldering ■ To prevent damage to the Module and to obtain long-term solder joint properties, you are advised to maintain the standards of good engineering practice for soldering. Material Properties ■ME3000V2 Module PCB: FR4 ■ Antenna pad: Gold plated pad 4.3 Antenna connector The ME3000V2 Module uses a microwave coaxial connector supplied by Murata Ltd. The product name is MM9329-2700B. The position of the antenna connector on the Module PCB can be seen in Figure 4-1. Operation Description Figure 4-1 Specification of MM9329-2700B connector Table 4-2 Product specifications of MM9329-2700B connector Part Number Rated Voltag Contact Resistan ce Withstandi ng Voltage (V) (ohm) (rms) Insulatio Resistan ce Durabili ty (cycles) Frequen cy Rating Temperatu re Range (GHz) (degree C) DC - 6.0 -40~+90 VSWR Center Conta ct Outer Conta ct 1.2 max. Copper Alloy Copper Alloy Gold plated Silver plated Insulator (M ohm) MM9329 -2700B 250 0.015 300 (AC) 500 min. 100 max. (DC~3GH z) Impedance : 50 ohm Engineeri ng plastic Operation Description 5 RF Interface 5.1 Overview A 50 ohm coaxial RF connector is provided for Module testing. However, we advise customers lead from the antenna pad at the RF line to the antenna. Figure 5-1 GSM Connector The module must provide a suitable antenna that works in the desired frequency band of operation. The Antenna connected to the GSM connector should be a dual band antenna supporting the GSM900 and DCS1800 bands. Band TX Frequency RX Frequency GSM 880~915 MHz 925~960 MHz DCS 1710~1785 MHz 1805~1880 MHz Note: TX refers to the transmit from the module into the antenna (Reverse Link of the GSM system), and RX refers to the receive from the antenna into the module (Forward Link of the GSM system). 5.2 Antenna Subsystem The antenna sub-system and its design is a major part of the final product integration. Special attention and care should be taken in adhering to the following guidelines. Operation Description 5.2.1 Antenna Specifications Choice of the antenna cable (type, length, performance, RF loss, etc) and antenna connector (type + losses) can have a major impact on the success of the design. 5.2.2 Cable Loss All cables have RF losses. Minimizing the length of the cable between the antenna and the RF connectors on the module will help obtain superior performance. High Quality/Low loss co-axial cables should be used to connect the antenna to the RF connectors. Contact the antenna vendor for the specific type of cable that interfaces with their antenna and ask them to detail the RF losses of the cables supplied along with the antenna. Typically, the cable length should be such that they have no more than 1-2dB of loss. Though the system will work with longer (loss) cables, this will degrade GSM system performance. Care should also be taken to ensure that the cable end connectors/terminations are well assembled to minimize losses and to offer a reliable, sturdy connection to the Module sub-system. This is particularly important for applications where the module is mounted on a mobile or portable environment where it is subject to shock and vibration. 5.2.3 Antenna Gain Minimum Requirements It is recommended that the antenna chosen have at least 2 dBi gain in the GSM900 band and 4 dBi in the PCS band. The Antenna subsystem shall also have at least 8 dB of return loss at the input with respect to a 50-ohm system. 5.2.4 Antenna Gain Maximum Requirements Our FCC Grant imposes a maximum gain for the antenna subsystem: 7 dBi for the GSM900 band and 13dBi for the DCS band. Warning: Excessive gain could damage sensitive RF circuits and void the warranty. 5.2.5 Antenna Matching The module’s RF connectors are designed to work with a 50-ohm subsystem. It is assumed that the antenna chosen has matching internal to it to match between the 50-ohm RF connectors and the antenna impedance. 5.2.6 PCB Design Considerations • The antenna subsystem should be treated like any other RF system or component. It should be isolated as much as possible from any noise generating circuitry including the interface signals via filtering and shielding. • As a general recommendation all components or chips operating at high frequencies such as micro controllers, memory, DC/DC converts and other RF components should not be placed too close to the module. When such cases exist, correct supply and ground de-coupling areas should be designed and validated. • Avoid placing the components around the RF connection and close to the RF line between the RF antenna and the module. • RF lines and cables should be as short as possible. • If using coaxial cable it should not be placed close to devices operating at low frequencies. Signals like charger circuits may require some EMI/RFI decoupling such as filter capacitors or ferrite beads. • Adding external impedance matching to improve the match to your cable and antenna assemblies is optional. Please contact the antenna vendor for matching requirements. • For better ESD protection one can implement a shock coil to ground and place it close to the RF connector. 5.2.7 Other Precautions It is essential to keep the voltage ripple to a minimum at this connection in order to avoid phase error. Insufficient power supply voltage can dramatically affect some RF performance such as TX power, modulation spectrum EMC performance, and spurious emissions and frequency error. The RF connections are 50-ohm impedance systems and are a DC short to ground. Best effort should be made to provide low insertion loss and shielding between the external antenna and RF connections over the frequency band of interest. 10 Operation Description 5.2.8 Grounding On terminals including the antenna, poor shielding can dramatically affect the sensitivity of the terminal.Moreover the power emitted through the antenna can affect the application. 11 Operation Description 6 Test Capabilities 6.1 Test Description 1) ME3000V2 RF Connectors: 2) Operating instructions 12 Operation Description Connect the sector to access terminal antenna connectors as shown in the following figure 6-1 figure 6-1 Connect the sector to access terminal antenna connectors as shown in the following figure 6-2: figure 6-2 6.2 GSM Test Equipment and Tools Lease or purchase of test equipment is available from vendors who provide this equipment for GSM over the-air simulation. Some suggested products include: • Agilent 8960 Series 10 E5515C CDMA Mobile Station Tester • Agilent E4440A Spectrum analyzer • Agilent E4438C Signal Generator • Agilent E4438C Signal Generator • Programmable Temperature-Humidity Testor • Programmable Temperature Concussion Testor RF Performance Requirements 13 Operation Description 6.2.1 GSM RF Rx Specification Frequency range 925~960 MHz/1805~1880 MHz Rx. Sensitivity -109 dBm for GSM, -108dBm for DCS (BER≤2.4%) Rx. Signal Range -25 dBm~ -109dBm(BER≤2.4%) 6.2.2 GSM RF Tx Specification: Max. frequency tolerance 880~915 MHz/1710~1785 MHz Max. Tx. Power GSM900: 32.2±1 dBm DCS1800:29.2±1 dBm Peak Phase Error RMS Phase Error -20°< PPE < 20° -5°< RMS < 5° Frequency Error GSM900: -90Hz< FE <90 Hz DCS1800: -180Hz< FE <180 Hz Mod +400kHz: <-60dBm Mod -400kHz: <-60dBm Mod+1800kHz:<-63dBm Mod-1800kHz:<-63dBm Modulation Spectrum Switching Spectrum Switching +400kHz:<-22dBm Switching -400kHz:<-22dBm Switching +1800kHz:<-27dBm Switching -1800kHz:<-27dBm Remarks: RF technical specification conforms to the following standards: 3GPP2 Recommended Minimum Performance Standards for GSM Spread Spectrum Mobile Stations 3GPP2 Recommended Minimum Performance Standards for GSM High Rate Packet Data Access Terminal Environmental Reliability Requirement 6.2.3 High Temperature Operation Test EUT Status Temperature Duration Power-on 70℃ 24h 6.2.4 Low Temperature Operation Test EUT Status Temperature Duration Power-on -30℃ 24h 6.2.5 High Temperature Storage Test EUT Status Temperature Power-off 85℃ 14 Operation Description Duration 24h 6.2.6 Low Temperature Storage Test EUT Status Temperature Duration Power-off -40℃ 24h 6.2.7 High Temperature High Humidity Operation Test EUT Status Temperature Humidity Duration Power-on 55℃ 93% 48h 6.2.8 Temperature Concussion Test EUT Status High Temperature High Temperature Duration Low Temperature Low Temperature Duration Cycle Times Power-off 85℃ 1h -45℃ 1h 10 ElectroMagnetic Compatibility 6.2.9 ESD Immunity Test EUT Status Test Voltage Reference Standard Idle mode and traffic mode Air ±8KV; Contact ±6KV IEC 61000-4-2 : 2001 6.2.10 Radiated Emissions Test EUT Status Limits for radiated disturbance Reference Standard Idle mode and traffic mode Class B ITE FCC Part 22H&24E 15
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Administrator Create Date : 2011:02:25 14:49:22+08:00 Modify Date : 2011:02:25 14:49:22+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : Administrator Title : Microsoft Word - Q78-ME3000V2 User Manual Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.0.0 (Windows) Document ID : uuid:8928fa21-931e-46db-a3ce-026358293352 Instance ID : uuid:0e394d57-dd9e-4014-b4a6-e8567599f24f Page Count : 15EXIF Metadata provided by EXIF.tools