Zebra Technologies AP6 Access Point Radio Module 6 User Manual 6521 IG

Zebra Technologies Corporation Access Point Radio Module 6 6521 IG

AP 6521 Install Guide Rev B 050412

Download: Zebra Technologies AP6 Access Point Radio Module 6 User Manual 6521 IG
Mirror Download [FCC.gov]Zebra Technologies AP6 Access Point Radio Module 6 User Manual 6521 IG
Document ID1702070
Application IDI6fT+I/lGODOFSHVYRR9JQ==
Document DescriptionAP 6521 Install Guide Rev B 050412
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize105.67kB (1320901 bits)
Date Submitted2012-05-21 00:00:00
Date Available2012-07-13 00:00:00
Creation Date2012-04-30 07:43:58
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2012-04-30 08:01:50
Document Title6521 IG.book
Document CreatorFrameMaker 8.0
Document Author: fdq876

AP-6521 Series Access Point
Installation Guide
MOTOROLA SOLUTIONS and the Stylized M Logo are registered in the US Patent & Trademark
Office. © Motorola Solutions, Inc. 2012. All rights reserved.
Table of Contents
1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.0 Hardware Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.3 Access Point Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4 Wall Mount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.5 Suspended Ceiling T-Bar Installation . . . . . . . . . . . . . . . . . . . . . . 11
2.6 Above the Ceiling (Plenum) Installation . . . . . . . . . . . . . . . . . . . . 13
2.7 LED Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.0 Defining a Basic Configuration . . . . . . . . . . . . . . . . . . . . . . . 17
3.1 Using the Initial Setup Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.1 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.2 Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.3 Radio Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.0 Regulatory Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
6.0 Motorola’s Enterprise Mobility Support Center . . . . . . . . . .51
Introduction
Introduction
AP-6521 Series access points are components of Motorola Solutions Wireless Controller System. An
AP-6521 links wireless 802.11a/b/g/n devices to the controller, enabling the growth of your wireless
network with a cost-effective alternative to standard access points. The AP-6521 Series access point
is an enterprise class 802.11n access point, installed in minutes anywhere a CAT-5e (or better) cable
is located.
An AP-6521 Series access point utilizes a setup wizard to define its operational mode as either a
Dependent mode AP, Standalone AP or Virtual Controller AP.
AP-6521 Series access points ship with a single dual-band radio supporting the 802.11a/b/g/n radio
bands. For more information on available SKUs, refer to the following:
Part Number
Description
AP-6521-60010-US
802.11a/b/g/n single radio, integrated antenna, high power,
United States model
AP-6521-60020-US
802.11a/b/g/n single radio, external antenna, high power,
United States model
AP-6521-60010-WR
802.11a/b/g/n single radio, integrated antenna, high power,
World Wide model
AP-6521-60020-WR
802.11a/b/g/n single radio, external antenna, high power,
World Wide model
The AP-6521 series Access Point is approved under MODEL: NCAP-500.
Motorola Solutions recommends the access point receive power and transfer data through the same
CAT-5e (or better) Ethernet cable using a Motorola Solutions Power Injector. The Power Injector
(Part No. AP-PSBIAS-2P2-AFR) is an 802.3af PoE injector. For information, see “Power Injector
System” on page 7.
A separate power supply (Part No. PWRS-147376-01R) is also available if you do not wish to use a
Power Injector. This standard power supply just supplies power to the access point’s power connector
and does not converge power and Ethernet within a single cable connection.
2 AP-6521 Series Access Point Installation Guide
1.1 Document Conventions
The following graphical alerts are used in this guide to indicate notable situations:
NOTE
Tips, hints, or special requirements that you should take note of.
CAUTION
WARNING!
Care is required. Disregarding a caution can result in data loss or
equipment malfunction.
Indicates a condition or procedure that could result in personal injury or
equipment damage.
1.2 Warnings
•
•
•
Read all installation instructions and site survey reports, and verify correct equipment
installation before connecting the access point.
Verify any device connected to this unit is properly wired and grounded.
Verify there is adequate ventilation around the device, and ambient temperatures meet
equipment operation specifications.
Introduction
1.3 Site Preparation
•
•
•
•
•
•
Consult your site survey and network analysis to determine specific equipment placement,
power drops etc.
Assign installation responsibility to the appropriate personnel.
Identify and document where all installed components are located.
Ensure adequate, dust-free ventilation to all installed equipment.
Prepare Ethernet port connections.
Verify cabling is within the maximum 100 meter allowable length.
1.4 Package Contents
The access point ships with the following:
•
•
•
•
•
One AP-6521 Series access point
Installation Guide (This Guide)
Rubber Wall Mount Spacers (4)
LED light pipe and badge
Wall mount screw and anchor kit
1.5 Features
•
•
•
•
•
•
•
One RJ-45 console connector
One RJ-45 Ethernet connector
LED Indicators
Safety wire tie point
Wall mount slots
Clips for suspended T-Bar mounting
DC power connector
An AP-6521 Series access point has one RJ-45 connector supporting an 10/100/1000 Ethernet port
connection and requires 802.3af compliant power from an external source.
The access point contains runtime firmware which enables the unit to boot after either a power up
or a watchdog reset. The runtime firmware on the access point can be updated via the Ethernet
interface.
4 AP-6521 Series Access Point Installation Guide
Hardware Installation
2.1 Installation Instructions
An AP-6521 Series access point can attach to a wall, mount under a suspended T-Bar or mount above
a ceiling. Selecting a mounting option based on the physical environment of the coverage area. Do
not mount the access point in a location that has not been approved in a site survey.
To prepare for an installation, perform the following:
1. Verify the contents of the box includes the intended access point and accessory hardware.
2. Review site survey and network analysis reports to determine the location and mounting
position for the access point.
3. Connect a CAT-5e or better Ethernet cable to a PoE compatible device and run the cable to
the installation site. Ensure there is sufficient cable slack to perform the installation steps.
4. Determine whether the access point is powered using a Power Injector system, combining
data and power to the access point’s GE1/PoE port or will be powered from a conventional
power adapter providing power only to the access point’s DC-48V connector.
2.2 Precautions
Before installing an access point:
•
•
Verify the intended deployment location is not prone to moisture or dust.
Verify the environment has a continuous temperature range between 0° C to 40° C.
Hardware Installation
2.3 Access Point Placement
For optimal performance, install the access point away from transformers, heavy-duty motors,
fluorescent lights, microwave ovens, refrigerators and other industrial equipment. Signal loss can
occur when metal, concrete, walls or floors block transmission. Install the access point in an open
area or add access points as needed to improve coverage.
Antenna coverage is analogous to lighting. Users might find an area lit from far away to be not bright
enough. An area lit sharply might minimize coverage and create dark areas. Uniform antenna
placement in an area (like even placement of a light bulb) provides even, efficient coverage.
Place the access point using the following guidelines:
•
•
•
Install the access point at an ideal height of 10 feet from the ground.
Orient the access point antennas vertically for best reception.
Point the access point antennas downward if attaching to the ceiling (external antenna
models only).
To maximize the access point’s radio coverage area, Motorola Solutions recommends conducting a
site survey to define and document radio interference obstacles before installing the access point.
2.3.1 Antenna Options
Motorola Solutions supports two antenna suites for the single radio, dual-band AP-6521 Series
access point. One antenna suite supporting the 2.4 GHz band, and another antenna suite supporting
the 5 GHz band. Select an antenna best suited to the intended operational environment of your access
point.
6 AP-6521 Series Access Point Installation Guide
The 2.4 GHz antenna suite includes the following models:
Part Number
Antenna Type
Approximate Gain (dBi)
ML-2452-APA2-01
Dipole
ML-2452-HPA5-036
Dipole
2.9
ML-2499-HPA3-01R
Dipole
4.6
ML-2499-APA2-01R
Dipole
ML-2452-APA2GA1-01
Dipole
ML-2452-PNA5-01R
Panel
4.5
ML-2452-PTA3M3-36
Patch
ML-2499-SD3-01R
Patch
4.8
Internal Antenna
PIFA
2.4
Hardware Installation
The 5 GHz antenna suite includes the following models:
Part Number
Antenna Type
Approximate Gain (dBi)
ML-2452-APA2-01
Dipole
ML-2452-HPA5-036
Dipole
4.9
ML-5299-APA1-01R
Dipole
ML-5299-HPA1-01R
Dipole
ML-2452-APA2GA1-01
Dipole
ML-2452-PNA5-01R
Panel
ML-2452-PTA3M3-36
Patch
ML-5299-PTA1-0R
Patch
Internal Antenna
PIFA
For a more exhaustive overview of the antennas and associated components supported by the
Motorola Solutions access point family, refer to the Enterprise Wireless LAN Antenna Specification
Guide available at http://support.symbol.com/support/product/manuals.do.
2.3.2 Power Injector System
The access point can receive power via an Ethernet cable connected to the GE1/PoE port.
When users purchase a WLAN solution, they often need to place access points in obscure locations.
In the past, a dedicated power source was required for each access point in addition to the Ethernet
infrastructure. This often required an electrical contractor to install power drops at each access point
location. The Power Injector merges power and Ethernet into one cable, reducing the burden of
installation and allowing optimal access point placement in respect to the intended coverage area.
The Power Injector (Part No. AP-PSBIAS-2P2-AFR) is an 802.3af PoE injector. The access point can
only use a Power Injector when connecting to the access point’s GE1/PoE port. The Power Injector is
separately ordered and not shipped with the access point. A separate Power Injector is required for
each access point comprising the network.
The Power Injector has no On/Off power switch. The Injector receives power and is ready for device
connection and operation as soon as AC power is applied. Refer to the guide shipped with the Power
Injector for a description of the device’s LEDs. The Power Injector can be installed free standing, on
an even horizontal surface or wall mounted using the Power Injector’s wall mounting key holes.
8 AP-6521 Series Access Point Installation Guide
The following guidelines should be adhered to before cabling the Power Injector to an Ethernet source
and an access point:
•
•
•
•
Do not block or cover airflow to the Power Injector.
Keep the Power Injector away from excessive heat, humidity, vibration and dust.
The Power Injector isn’t a repeater, and does not amplify the Ethernet signal. For optimal
performance, ensure the Power Injector is placed as close as possible to the Ethernet
switch. This allows the access point to be deployed away from power drops.
Ensure the cable length from the Ethernet source (host) to the Power Injector and access
point does not exceed 100 meters (333 ft).
Hardware Installation
CAUTION
To avoid problematic performance and restarts, disable PoE from a
wired controller port connected to an access point if mid-span power
sourcing equipment (PSE) is used between the two, regardless of the
manufacturer.
CAUTION
Ensure AC power is supplied to the Power Injector using an AC cable
with an appropriate ground connection approved for the country of
operation.
NOTE
If not using the Power Injector to power the access point, the only other
approved power solution is the standard power supply (Part Number
PWRS-147376-01R). The standard power supply does not converge data
and power in one cable, and requires a separate data Ethernet
connection in addition to a power connection. This product is intended to
be supplied by a listed power adapter marked “Class 2” or “L.P.S” (or
“Limited Power Source”) and rated from 48Vdc, 0.27A minimum.
2.4 Wall Mount Installation
To support wall mount installations, the access point is fastened directly to a flat wall surface. The
wall should be of gypsum board, plaster, wood or concrete in composition.
CAUTION
An access point should be wall mounted to concrete or plasterwall-board (dry wall) only. Do not wall mount the access point to
combustible surfaces.
To install the access point to a wall:
1. Orient the access point by either its width or length.
2. Mark the mounting surface at the target screw insertion points.
3. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall
mounting screw and stop when there is 1mm between the screw head and the wall.
If pre-drilling a hole, the recommended hole size is 2.8mm (0.11in.) if the screws are going
directly into the wall and 6mm (0.23in.) if wall anchors are being used.
4. If required, install and attach a security cable to the access point lock port.
10 AP-6521 Series Access Point Installation Guide
5. Attach the antennas to their correct connectors.
For information on available antennas, see “Antenna Options” on page 5.
6. Place the large center opening of each of the mount slots over the screw heads.
7. Slide the access point down along the mounting surface to hang the mount slots on the
screw heads
8. Cable the access point using either the Power Injector solution or an approved line cord and
power supply.
CAUTION
Do not connect to the power source until the cabling of the access
point is complete. Ensure PoE is not connected to the access point’s
console connector or risk rendering the console connector
permanently inoperable.
For Motorola Power Injector installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host)
and the Power Injector Data In connector.
b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector Data &
Power Out connector and the access point GE1/PoE port.
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and
access point does not exceed 100 meters (333 ft). The Power Injector has no On/Off
power switch. The Power Injector receives power as soon as AC power is applied. For
more information on using the Power Injector, see “LED Indicator” on page 15.
For power adapter (Part Number PWRS-147376-01R) and line cord installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host)
and the access point’s GE1/PoE.
b. Verify the power adapter is correctly rated according the country of operation.
c. Connect the power supply line cord to the power adapter.
d. Attach the power adapter cable to the DC-48V power connector on the access point.
e. Attach the power supply line cord to a power supply.
9. Verify the behavior of the access point LEDs. For more information, see “LED Indicator” on
page 15.
10. The access point is ready to configure. For information on basic access point device
configuration, see “Defining a Basic Configuration” on page 17.
Hardware Installation
2.5 Suspended Ceiling T-Bar Installation
A suspended ceiling mount requires holding the access point up against the T-bar of a suspended
ceiling grid and twisting the access point chassis onto the T-bar.
To install the access point on a ceiling T-bar:
1. If desired, install and attach a security cable to the access point lock port.
2. If using an external antenna model, attach the antennas to their correct connectors.
3. For more information on the antenna options available to the access point, see “Antenna
Options” on page 11.
4. Cable the access point using either the Power Injector solution or an approved line cord and
power supply.
CAUTION
Do not connect to the power source until the cabling of the access
point is complete. Ensure PoE is not connected to the access point’s
console connector or risk rendering the console connector
permanently inoperable.
For Power Injector installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host)
and the Power Injector Data In connector.
b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector Data &
Power Out connector and the access point’s GE1/PoE port.
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and
access point does not exceed 100 meters (333 ft). The Power Injector has no On/Off
power switch. The Power Injector receives power as soon as AC power is applied. For
more information on using the Power Injector, see “Power Injector System” on page 7.
For power adapter (Part Number PWRS-147376-01R) and line cord installations:
a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the access
point’s GE1/PoE port.
b. Verify the power adapter is correctly rated according the country of operation.
c. Connect the power supply line cord to the power adapter.
d. Attach the power adapter cable to the DC-48V power connector on the access point.
e. Attach the power supply line cord to a power supply.
11
12 AP-6521 Series Access Point Installation Guide
5. Verify the behavior of the access point LEDs. For more information, see “LED Indicator” on
page 15.
6. Align the bottom of the ceiling T-bar with the back of the access point.
7. Orient the access point chassis by its length and the length of the ceiling T-bar.
8. Rotate the access point chassis 45 degrees clockwise.
9. Push the back of the access point chassis on to the bottom of the ceiling T-bar.
10. Rotate the access point chassis 45 degrees counter-clockwise. The clips click as they fasten
to the T-bar.
11. Verify the behavior of the access point LEDs. For more information, see “LED Indicator” on
page 15.
12. The access point is ready to configure. For information on basic access point device
configuration, see “Defining a Basic Configuration” on page 17.
Hardware Installation
2.6
Above the Ceiling (Plenum) Installation
An above the ceiling installation requires placing the access point above a suspended ceiling and
installing the provided light pipe under the ceiling tile for viewing the status LED of the unit. An above
the ceiling deployment enables installations compliant with drop ceilings, suspended ceilings and
industry standard tiles from .625 to .75 inches thick.
NOTE
The access point is Plenum rated to UL2043 and NEC1999 to support
above the ceiling installations. To ensure UL compliance and proper
access point operation within the Air Handling Plenum, the access point
must be installed with the bottom surface of the unit in contact with the
un-finished surface of the ceiling tile. Placing the product on the ceiling
tile will facilitate the positioning of the light pipe. Placement of the
product in the Air Handling Plenum off of, or away from, the unfinished
surface of the ceiling tile is not UL approved and certification of UL2043
compliance would be void in that case.
CAUTION
Motorola Solutions does not recommend mounting the access point
directly to suspended ceiling tile with a thickness less than 12.7mm
(0.5in.) or a suspended ceiling tile with an unsupported span greater
than 660mm (26in.).
The mounting hardware required to install the access point above a ceiling consists of:
•
•
•
Light pipe
Badge for light pipe
Decal for badge
To install the access point above a ceiling:
1.
2.
3.
4.
5.
If possible, remove the adjacent ceiling tile from its frame and place it aside.
If required, install and attach a security cable to the access point’s lock port.
Mark a point on the finished side of the tile where the light pipe is to be located.
Create a light pipe path hole in the target position on the ceiling tile.
Use a drill to make a hole in the tile the approximate size of the access point LED light pipe.
CAUTION
Motorola Solutions recommends care be taken not to damage the
finished surface of the ceiling tile when creating the light pipe hole
and installing the light pipe.
13
14 AP-6521 Series Access Point Installation Guide
6. Remove the light pipe’s rubber stopper (from the access point) before installing the light
pipe.
7. Connect the light pipe to the bottom of the access point. Align the tabs and rotate
approximately 90 degrees. Do not over tighten.
8. Fit the light pipe into hole in the tile from its unfinished side.
9. Place the decal on the back of the badge and slide the badge onto the light pipe from the
finished side of the tile.
10. Attach the antennas to their correct connectors.
For information on the antennas available to the access point, see “Antenna Options” on
page 5.
11. Align the ceiling tile into its former ceiling space.
13. Cable the access point using either the Power Injector solution or an approved line cord and
power supply.
CAUTION
Do not connect to the power source until the cabling of the access
point is complete. Ensure PoE is not connected to the access point’s
console connector or risk rendering the console connector
permanently inoperable.
For Power Injector installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host)
and the Power Injector Data In connector.
b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector Data &
Power Out connector and the access point’s GE1/PoE port.
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and
access point does not exceed 100 meters (333 ft). The Power Injector has no On/Off
power switch. The Power Injector receives power as soon as AC power is applied. For
more information on using the Power Injector, see “Power Injector System” on page 7.
For power adapter (Part Number PWRS-147376-01R) and line cord installations:
a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the access
point’s GE1/PoE port.
b. Verify the power adapter is correctly rated according the country of operation.
c. Connect the power supply line cord to the power adapter.
d. Attach the power adapter cable to the DC-48V power connector on the access point.
e. Attach the power supply line cord to a power supply.
Hardware Installation
12. Verify the behavior of the access point LED light pipe. For more information, see
“LED Indicator” on page 15.
13. Place the ceiling tile back in its frame and verify it is secure.
14. The access point is ready to configure. For information on basic access point device
configuration, see “Using the Initial Setup Wizard” on page 17.
2.7 LED Indicator
An AP-6521 Series access point has a single LED activity indicator on the front of the unit.
The LED provides a status display indicating error conditions, transmission, and network activity for
the 5 GHz 802.11a/n (amber) radio or the 2.4 GHz 802.11b/g/n (green) radio.
15
16 AP-6521 Series Access Point Installation Guide
Task
5 GHz Activity LED (Amber)
2.4 GHz Activity LED (Green)
Unadopted
Off
Blinking 5 times per second
Normal
Operation
• If this radio band is enabled:
Blink at 5 second interval
• If this radio band is disabled:
Off
• If there is activity on this band:
Blink at a 1Hz
• If this radio band is enabled:
Blink at 5 second interval
• If this radio band is disabled:
Off
• If there is activity on this band:
Blink at a 1Hz
Firmware
Update
On
Off
Locate AP
Mode
Blink at 5Hz
Blink at 5Hz
Defining a Basic Configuration
Defining a Basic Configuration
An AP-6521 Series access point can utilize an initial setup wizard to streamline the process of initially
accessing the wireless network. The wizard defines the access point’s operational mode, deployment
location, basic security, network and WLAN settings.
3.1 Using the Initial Setup Wizard
Once the AP-6521 is installed and powered on, complete the following steps to get the access point
up and running and access management functions:
1. The access point’s IP address is optimally provided using DHCP. A zero config IP address can
also be derived if DHCP resources are unavailable. Using zero config, the last two octets in
the IP address are the decimal equivalent of the last two bytes in the access point’s
hardcoded MAC address.
For example:
MAC address - 00:C0:23:00:F0:0A
Zero-config IP address - 169.254.240.10
To derive the access point’s IP address using its MAC address:
a. Open the Windows calculator be selecting Start > All Programs > Accessories >
Calculator. This menu path may vary slightly depending on your version of Windows.
b. With the Calculator displayed, select View > Scientific. Select the Hex radio button.
c. Enter a hex byte of the access point’s MAC address. For example, F0.
d. Select the Dec radio button. The calculator converts F0 into 240. Repeat this process for
the last access point MAC address octet.
2. Point the Web browser to the access point’s IP address. The following login screen displays:
17
18 AP-6521 Series Access Point Installation Guide
3. Enter the default username admin in the Username field.
4. Enter the default password motorola in the Password field.
5. Click the Login button to load the management interface.
NOTE
When logging in for the first time, you’re prompted to change the
password to enhance device security in subsequent logins.
NOTE
If you get disconnected when running the wizard, you can connect again
with the access point’s actual IP address (once obtained) and resume the
wizard.
Defining a Basic Configuration
6. If this is the first time the management interface has been accessed, a dialogue displays to
start the wizard. Select Start Wizard to run the initial setup wizard.
19
20 AP-6521 Series Access Point Installation Guide
The first page of the Initial AP Setup Wizard displays the Navigation Panel and Introduction
for the configuration activities comprising the access point's initial setup
A green checkmark to the left of an item in the Navigation Panel defines the listed task as
having its minimum required configuration parameters set correctly. A red X defines the task
as still requiring at least one parameter be defined correctly.
Defining a Basic Configuration
The Introduction screen displays a list of the basic configuration activities supported by the
Initial Setup Wizard.
7. Select Save/Commit within each page to save the updates made to that page's
configuration. Select Next to proceed to the next page listed in the Navigation Panel. Select
Back to revert to the previous screen in the Navigation Panel without saving your updates.
NOTE
While you can navigate to any page in the navigation panel, you cannot
complete the Initial AP Setup Wizard until each task in the Navigation
Panel has a green checkmark.
8. Select Next. The Initial AP Setup Wizard displays the Access Point Type screen to define
the access point's Standalone versus Virtual Controller AP functionality and the way the
access point is adopted to a controller.
21
22 AP-6521 Series Access Point Installation Guide
9. Select an Access Point Type from the following options:
• Virtual Controller AP - When more than one access point is deployed, a single access
point can function as a Virtual Controller AP. Up to 24 access points can be connected to,
and managed by, a single Virtual Controller AP of the same AP-6521 model.
• Standalone AP -Select this option to deploy this access point as an autonomous fat
access point. A Standalone AP isn't managed by a Virtual Controller AP, or adopted by a
RFS series controller.
Defining a Basic Configuration
NOTE
•
If designating the access point as a Standalone AP, Motorola Solutions
recommends the access point’s UI be used exclusively to define its device
configuration, and not the CLI. The CLI provides the ability to define more
than one profile and the UI does not. Consequently, the two interfaces
cannot be used collectively to manage profiles without an administrator
encountering problems.
Adopted to Controller - Select this option when deploying the access point as a controller
managed (Dependent mode) access point. Selecting this option closes the Initial AP Setup
Wizard. An adopted access point obtains its configuration from a profile stored on its
managing controller. Any manual configuration changes are overwritten by the controller
upon reboot.
Select the Automatic controller discovery option to enable the access point to be
discovered and adopted using layer 2 settings. If preferring layer 3 adoption, select the
Static Controller Configuration option, and define the addresses of the preferred
controllers. If using the static method, you’ll also need to define whether the access point
receives an IP address using DHCP or if IP resources are provided statically.
10. Select Next. The Initial AP Setup Wizard displays the Access Point Mode screen to define
the access point's routing or bridging mode functionality.
23
24 AP-6521 Series Access Point Installation Guide
11. Select an Access Point Mode from the available options.
• Router Mode - In Router Mode, the access point routes traffic between the local network
(LAN) and the Internet or external network (WAN). Router mode is recommended in a
deployment supported by just a single access point.
• Bridge Mode - In Bridge Mode, the AP depends on an external router for routing LAN and
WAN traffic. Routing is generally used on one device, whereas bridging is typically used
in a larger network. Thus, select Bridge Mode when deploying this access point with
numerous peer APs supporting clients on both the 2.4 and 5GHz radio bands.
Defining a Basic Configuration
12. Select Next. The Initial AP Setup Wizard displays the LAN Configuration screen to set the
access point's LAN interface configuration.
25
26 AP-6521 Series Access Point Installation Guide
13. Set the following DHCP and Static IP Address/Subnet information for the LAN interface:
• Use DHCP - Select the checkbox to enable an automatic network address configuration
using the access point’s DHCP server. An AP-6521 access point does not have an onboard
DHCP server and an external DHCP server must be utilized.
• Static IP Address/Subnet - Enter an IP Address and a subnet for the access point's LAN
interface. If Use DHCP is selected, this field is not available. When selecting this option,
define the following DHCP Server and Domain Name Server (DNS) resources, as those
fields will become enabled on the bottom portion of the screen.
• Use on-board DHCP server to assign IP addresses to wireless clients -Select the
checkbox to enable the access point’s DHCP server to provide IP and DNS information
to clients on the LAN interface.
• Range - Enter a starting and ending IP Address range for client assignments on the
access point's LAN interface. Avoid assigning IP addresses from x.x.x.1 - x.x.x.10 and
x.x.x.255, as they are often reserved for standard network services. This is a required
parameter.
• Default Gateway - Define a default gateway address for use with the default
gateway. This is a required parameter.
• DNS Forwarding - Select this option to allow a DNS server to translate domain names
into IP addresses. If this option is not selected, a primary and secondary DNS resource
must be specified. DNS forwarding is useful when a request for a domain name is made
but the DNS server, responsible for converting the name into its corresponding IP
address, cannot locate the matching IP address.
• Primary DNS - Enter an IP Address for the main Domain Name Server providing DNS
services for the access point's LAN interface.
• Secondary DNS - Enter an IP Address for the backup Domain Name Server providing
DNS services for the access point's LAN interface
14. Select Next. The Initial AP Setup Wizard displays the WAN Configuration screen to set
the access point's WAN interface configuration.
Defining a Basic Configuration
15. Set the following DHCP and Static IP Address/Subnet information for the WAN interface:
• Use DHCP - Select the checkbox to enable an automatic network address configuration
using the access point’s DHCP server.
• Static IP Address/Subnet - Enter an IP Address/Subnet and gateway for the access
point's WAN interface. These are required fields
27
28 AP-6521 Series Access Point Installation Guide
• The port connected to the WAN - Select the port used as the physical access point
connection to the external network. This ports available differ depending on the access
point model deployed. Access point models with a single port have this option fixed.
• Enable NAT on the WAN Interface - Select the checkbox to allow traffic to pass between
the access point's WAN and LAN interfaces.
16. Select Next. The Initial AP Setup Wizard displays the Radio Configuration screen to
define support for the 2.4GHz radio band, 5GHz radio band or to set the radio's functionality
as a dedicated sensor. An AP-6521 is supports a single dual-band radio.
NOTE
The ADSP Sensor Support field displays at the bottom of the screen
only if a radio has been dedicated as a sensor.
Defining a Basic Configuration
17. Set the following parameters for the radio:
• Configure as a Date Radio - Select this option to dedicate this radio for WLAN client
support in either the selected 2.4 or 5GHz radio band.
29
30 AP-6521 Series Access Point Installation Guide
•
Radio Frequency Band - Select either the 2.4GHz or 5.0GHz radio band to use with the
radio when selected as a Data Radio. The selected band is used for WLAN client
support. Considers selecting one radio for 2.4GHz and another for 5GHz support (if
using a dual or three radio model) when supporting clients in both the 802.11bg and
802.11n bands.
• Power Level - Use the spinner control to select a 1 - 23 dBm minimum power level to
assign to this radio in selected 2.4 or 5.0 GHz band. 1 dBm is the default setting.
• Channel Mode - Select either Random, Best or Static. Select Random for use with a
802.11a/n radio. To comply with Dynamic Frequency Selection (DFS) requirements in
the European Union, the 802.11a/n radio uses a randomly selected channel each time
the access point is powered on.
Select Best to enable the access point to scan non-overlapping channels and listen
for beacons from other access points. After the channels are scanned, it will select
the channel with the fewest access points. In the case of multiple access points on
the same channel, it will select the channel with the lowest average power level.
When Constantly Monitor is selected, the access point will continuously scan the
network for excessive noise and sources of interference. Select Static to assign the
access point a permanent channel and scan for noise and interference only when
initialized.
• Configure as a Sensor Radio - Select this option to dedicate the radio to sensor support
exclusively. When functioning as a sensor, the radio scans in sensor mode across all
channels within the 2.4 and 5.0GHz bands to identify potential threats within the access
point managed network. If dedicating a radio as a sensor resource, a primary and
secondary ADSP server must be specified as an ADSP management resource.
NOTE
If configuring an AP-6521 model access point as a sensor, the access
point will require a reboot before its sensor functionality is invoked. The
reboot can take place at the completion of the Initial AP Setup Wizard.
• Disable the Radio - Select this option to disable this radio, thus prohibiting it from either
providing WLAN or sensor support. Verify this course action with your network
administrator before rendering the radio offline.
18. Select Next. The Initial AP Setup Wizard displays the Wireless LAN Setting screen to
define network address and security settings for two WLAN configurations available to the
access point as part of the Initial AP Setup Wizard. Once the access point has an initial
configuration defined, numerous additional WLAN configurations can be set.
Defining a Basic Configuration
19. Set the following parameters for each of the two WLAN configurations available as part of
this Initial AP Setup Wizard:
• SSID - Enter or modify the Services Set Identification (SSID) associated with the WLAN.
The WLAN name is auto-generated using the SSID until changed by the user. The
maximum number of characters is 32. Do not use < > | “ & \ ? , This is a required
parameter for each WLAN.
31
32 AP-6521 Series Access Point Installation Guide
• WLAN Type - Set the data protection scheme used by clients and access points within
the WLAN. The following options are available:
• No Authentication and no Encryption - Select this option to provide no security
between the access point and connected clients on this WLAN.
• Captive Portal Authentication and No Encryption - Select this option to use a Web
page (either internally or externally hosted) to authenticate users before access is
granted to the network. If using this option, define whether a local or external
RADIUS authentication resource is used.
• PSK Authentication and WPA2 Encryption - Select the option to implement a preshared key that must be correctly shared between the access point and requesting
clients using this WLAN. If using this option, specify a WPA key in either ASCII (8-63
characters) or HEX (64 characters) format.
• EAP Authentication and WPA2 Encryption - Select this option to authenticate clients
within this WLAN through the exchange and verification of certificates. If using this
option, define whether a local or external RADIUS authentication resource is used.
• WPA Key - If a WPA key is required (PSK Authentication and WPA2 Encryption), enter an
alphanumeric string of 8 to 63 ASCII characters or 64 HEX characters as the primary
string both transmitting and receiving authenticators must share. The alphanumeric
string allows character spaces. This passphrase saves the administrator from entering
the 256-bit key each time keys are generated.
• RADIUS Server - If the WLAN type requires a RADIUS server to validate user credentials,
designate whether the access point is using an External RADIUS Server resource or
the access point's own Onboard RADIUS Server. If using an external RADIUS server
resource, provide the IP address of the external server and the shared secret used to
authenticate the request.
NOTE
If using the access point’s onboard RADIUS server, an additional RADIUS
Server Configuration screen displays within the Navigation Panel on
the left-hand side of the screen. Use this screen to create user accounts
validated when the access point authenticates client connection requests
to the onboard RADIUS server.
20. Select Next. The Initial AP Setup Wizard displays the RADIUS Server Configuration
screen if the access point’s onboard RADIUS server is required to validate user requests. If
an onboard RADIUS server is not required, the Initial AP Setup Wizard displays the Country/
Date/Time screen to set device deployment, administrative contact and system time
information.
Defining a Basic Configuration
21. Refer to the Username, Password, Description and Actions columns to review credentials of
existing RADIUS Server user accounts. Add new accounts or edit the properties of existing
accounts as updates are required.
33
34 AP-6521 Series Access Point Installation Guide
22. Refer to the Add On-Board RADIUS Server Users field to set the following parameters
for a user account:
• Username - If adding a new user account, create a username up to X characters in
length. The username cannot be revised if modifying the user configuration. This is a
required parameter.
• Password - Provide (or modify) a password between X - X characters in length entered
each time a requesting client attempts access to the AP managed network using the
access point's onboard RADIUS server. This is a required parameter.
• Confirm Password - Re-enter (or modify) the password as a means of confirming the
password. This is a required parameter.
• Description - Optionally provide a description of the user account as means of further
differentiating it from others.
23. When completed, select Add User to commit a new user, Modify User to commit a
modified user or Reset to clear the screen without updating the configuration. Selecting
Reset clears the field of all entered user account information.
24. Select Next. The Initial AP Setup Wizard displays the Country/Date/Time screen to set
device deployment, administrative contact and system time information. The system time
can either be set manually or be supplied by a dedicated Network Time Protocol (NTP)
resource.
Defining a Basic Configuration
25. Refer to the Country and Time Zone field to set the following device deployment
information:
• Location - Define the location of the access point. The Location parameter acts as a
reminder of where the AP can be located within the Motorola Solutions managed
wireless network.
35
36 AP-6521 Series Access Point Installation Guide
• Contact - Specify the contact information for the administrator. The credentials provided
should accurately reflect the individual responding to service queries.
• Country - Select the Country where the access point is deployed. The access point
prompts for the correct country code on the first login. A warning message also displays
stating an incorrect country setting may result in illegal radio operation. Selecting the
correct country is central to legal operation. Each country has its own regulatory
restrictions concerning electromagnetic emissions and the maximum RF signal strength
that can be transmitted. This is a required parameter.
• Time Zone - Set the time zone where the access point is deployed. This is a required
parameter. The setting should be complimentary with the selected deployment country.
26. If an NTP resource is unavailable, set the System Date and Time (calendar date, time and
AM/PM designation).
27. Optionally enter the IP address of a server used to provide system time to the access point.
Once the IP address is entered, the Network Time Protocol (NTP) functionality is
engaged automatically for synchronization with the NTP resource.
28. If an NTP resource is unavailable, set the System Date and Time (calendar date, time and
AM/PM designation).
29. Optionally enter the IP address of a server used to provide system time to the access point.
Once the IP address is entered, the Network Time Protocol (NTP) functionality is
engaged automatically for synchronization with the NTP resource.
30. Select Next. The Initial AP Setup Wizard displays the Summary and Commit screen to
summarize the screens (pages) and settings updated using the Initial AP Setup Wizard.
There's no user intervention or additional settings required within this screen. Its an
additional means of validating the configuration before its deployed. However, if a screen
displays settings not intended as part of the initial configuration, the screen can be selected
from within the Navigation Panel and its settings modified accordingly.
Defining a Basic Configuration
31. If the configuration displays as intended, select the Save/Commit button to implement
these settings to the access point’s configuration. If additional changes are warranted based
on the summary, either select the target page from the Navigational Panel, or use the Back
and Next buttons to scroll to the target screen.
37
38 AP-6521 Series Access Point Installation Guide
Specifications
4.1 Electrical Characteristics
An AP-6521 Series access point has the following electrical characteristics:
Max DC Power
Consumption
12.95W (270mA@48V)
4.2 Physical Characteristics
An AP-6521 Series access points has the following physical characteristics:
Dimensions
6.0 (Length) x 5.5 (Width) x 1.63 (Tall) - Inches
152.4 (Length) x 139.7 (Width) x 41.1 (Tall) - Millimeters
Housing
Plastic
Weight
0.60 lbs/0.272 kg
Operating
Temperature
32°F to 104°F/0°C to 40°C
Storage Temperature
-40°F to 158°F/-40°C to 70°C
Operating Humidity
5 to 95% Relative Humidity non-condensing
Storage Humidity
85% Relative Humidity non-condensing
Operating Altitude
(max)
8,000 ft @ 28°C
Storage Altitude
(max)
30,000 ft @ 12°C
Electrostatic
Discharge
+/-15kV Air and +/-8kV Contact @ 50% Relative Humidity
Specifications
4.3 Radio Characteristics
An AP-6521 Series access point has the following radio characteristics:
Radio Characteristic
AP-6521 High Power
Operating Channel (2.4 GHz)
Channel 1 to 13 (2412 to 2472 MHz)
*Japan Only - Channel 14 (2484 MHz)
Operating Channel (5. GHz)
Channels 36 - 165
802.11a Data Rates
6, 9, 12, 18, 24, 36, 48, 54 Mbps
802.11b Data Rates
1, 2, 5.5, 11 Mbps
802.11g Data Rates
6, 9, 12, 18, 24, 36, 48, 54 Mbps
802.11n Data Rates
MCS0 to MCS15 at both HT20 and HT40 modes
Max Transmit Power (2.4GHz)
27 dBm
Max Transmit Power (5 GHz)
22 dBm
Transmit Power Adjustment
1 dB
NOTE
Channel 14 is valid only for 802.11b in Japan, 802.11g is not supported.
39
40 AP-6521 Series Access Point Installation Guide
Regulatory Information
5.1 Regulatory Overview
This device is approved under the Motorola Solutions brand.
This guide applies to Part Numbers AP-6521-60010-US, AP-6521-60020-US, AP-6521-60010-WR and
AP-6521-60020-WR. AP-6521 Series access points are approved under MODEL: NCAP-500.
All Motorola Solutions devices are designed to be compliant with rules and regulations in locations
they are sold and will be labeled as required.
Any changes or modifications to Motorola Solutions equipment, not expressly approved by Motorola
Solutions, could void the user’s authority to operate the equipment.
Motorola Solutions Access Points must be professionally installed and configured so that the Radio
Frequency Output Power will not exceed the maximum allowable limit for the country of operation.
Antennas: Use only the supplied or an approved replacement antenna. Unauthorized antennas,
modifications, or attachments could cause damage and may violate regulations. Use of an
unapproved antenna is illegal under FCC regulations subjecting the end user to fines and equipment
seizure.
5.2 Wireless Device Country Approvals
Regulatory markings, subject to certification, are applied to the device signifying the radio(s) is/are
approved for use in the following countries: United States, Canada, Japan, China, S. Korea, Australia,
and Europe.
Please refer to the Declaration of Conformity (DoC) for details of other country markings. This is
available at
http://www.motorola.com/Business/US-EN/Document+Library/Declaration+of+Conformity
Note: For 2.4GHz or 5GHz Products: Europe includes, Austria, Belgium, Bulgaria, Czech Republic,
Cyprus, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,
Slovak Republic, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
Operation of the device without regulatory approval is illegal.
Regulatory Information
5.2.1 Country Selection – Note for AP & Wireless Controller
Select only the country in which you are using the device. Any other selection will make the operation
of this device illegal. The US version of the Access Point will only have US listed in the country
selection table. The US version will be sold / used in the US protectorates: American Samoa, Guam,
Puerto Rico, US Virgin Islands.
5.2.2 Frequency of Operation – FCC and IC
5 GHz Only
The use on UNII (Unlicensed National Information Infrastructure) Band 1 5150-5250 MHz is restricted
to indoor use only, any other use will make the operation of this device illegal.
Industry Canada Statement:
Caution: The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-Channel mobile satellite systems. High power radars are allocated as
primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars
could cause interference and/or damage to LE-LAN devices.
Avertissement: Le dispositive fonctionnant dans la bande 5150-5250 MHz est réservé uniquement
pour une utilisation à l'intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes
de satellites mobiles utilisant les mêmes canaux. Les utilisateurs de radars de haute puissance sont
désignés utilisateurs principaux (c.-à-d., qu'ils ont la priorité) pour les bands 5250-5350 MHz et 56505850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs
LAN-EL
2.4 GHz Only
The available channels for 802.11 b/g operation in the US are Channels 1 to 11. The range of channels
is limited by firmware.
5.3 Health and Safety Recommendations
5.3.1 Warnings for the use of Wireless Devices
Please observe all warning notices with regard to the usage of wireless devices
5.3.2 Potentially Hazardous Atmospheres – Fixed Installations
You are reminded of the need to observe restrictions on the use of radio devices in fuel depots,
chemical plants etc. and areas where the air contains chemicals or particles (such as grain, dust, or
metal powders).
41
42 AP-6521 Series Access Point Installation Guide
5.3.3 Safety in Hospitals
Wireless devices transmit radio frequency energy and may affect medical electrical equipment.
When installed adjacent to other equipment, it is advised to verify that the adjacent equipment is not
adversely affected.
Pacemakers
Pacemaker manufacturers recommended that a minimum of 15cm (6 inches) be maintained between
a handheld wireless device and a pacemaker to avoid potential interference with the pacemaker.
These recommendations are consistent with independent research and recommendations by
Wireless Technology Research.
Persons with Pacemakers:
•
•
•
•
Should ALWAYS keep the device more than 15cm (6 inches) from their pacemaker when
turned ON.
Should not carry the device in a breast pocket.
Should use the ear furthest from the pacemaker to minimize the potential for interference.
If you have any reason to suspect that interference is taking place, turn OFF your device.
Other Medical Devices
Please consult your physician or the manufacturer of the medical device, to determine if the operation
of your wireless product may interfere with the medical device.
5.4 RF Exposure Guidelines
5.4.1 Safety Information
Reducing RF Exposure—Use Properly
Only operate the device in accordance with the instructions supplied.
5.5 International
The device complies with internationally recognized standards covering human exposure to
electromagnetic fields from radio devices. For information on “International” human exposure to
eletromagnic fields refer to the Motorola Solutions Declaration of Conformity (DoC) at
http://www.motorola.com/Business/US-EN/Document+Library/Declaration+of+Conformity
Regulatory Information
5.6 EU
Remote and Standalone Antenna Configurations
To comply with EU RF exposure requirements, antennas that are mounted externally at remote
locations or operating near users at stand-alone desktop of similar configurations must operate with
a minimum separation distance of 20 cm from all persons.
5.7 US and Canada
Co-located statement
To comply with FCC RF exposure compliance requirements, the antennas used with this transmitter
must not be co-located, or operating in conjunction, with any other transmitter/antenna except those
already approved in this filling.
Remote and Standalone Antenna Configurations
To comply with FCC RF exposure requirements, antennas that are mounted externally at remote
locations or operating near users at stand-alone desktop of similar configurations must operate with
a minimum separation distance of 20 cm from all persons.
5.8 Power Supply
This device is powered from either a model PWRS-147376-01R 48 volt power supply or a 802.3af
compliant power source which is UL approved and certified by the appropriate agencies.
5.9 Radio Frequency Interference Requirements—FCC
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected
Consult the dealer or an experienced radio/TV technician for help
43
44 AP-6521 Series Access Point Installation Guide
Radio Transmitters (Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Restricted Band 5.60 – 5.65 GHz
5.10 Radio Frequency Interference Requirements – Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
5.10.1 Radio Transmitters
For RLAN Devices:
The use of 5 GHz RLAN’s, for use in Canada, have the following restrictions:
• Restricted Band 5.60 – 5.65 GHz
L'utilisation de RLAN de 5 GHz, pour utilisation au Canada est soumise aux restrictions suivantes:
• Bande Restreinte de 5,60 à 5,65 GHz
This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Ce dispositif est conforme à la norme CNR-210 d'Industrie Canada applicable aux appareils radio
exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne
doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y
compris un brouillage susceptible de provoquer un fonctionnement indésirable.
Label Marking: The Term "IC:" before the radio certification only signifies that Industry Canada
technical specifications were met.
5.11 CE Marking and European Economic Area (EEA)
The use of 2.4 GHz RLAN’s, for use through the EEA, have the following restrictions:
•
•
•
Maximum radiated transmit power of 100 mW EIRP in the frequency range 2.400 -2.4835
GHz.
France, outside usage is restricted to 2.4 – 2.454 GHz.
Italy requires a user license for outside usage.
Regulatory Information
5.12 Mexico
"La operación de este equipo está sujeta a lassiguientes dos condiciones: (1) es posible que este
equipo o dispositivo no cause interferencia perjudicialy (2) este equipo o dispositivo debe aceptar
cualquierinterferencia, incluyendo la que pueda causar suoperación no deseada."
5.13 Statement of Compliance
Motorola Solutions hereby, declares that this device is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC. A Declaration of Conformity may be obtained
from http://www.motorola.com/Business/US-EN/Document+Library/Declaration+of+Conformity.
45
46 AP-6521 Series Access Point Installation Guide
5.14 Waste Electrical and Electronic Equipment (WEEE)
English: For EU Customers: All products at the end of their life must be returned to for
recycling. For information on how to return product, please go to:
http://www.symbol.com/environmental_compliance.
Dansk: Til kunder i EU: Alle produkter skal returneres til Symbol til recirkulering, når de er
udtjent. Læs oplysningerne om returnering af produkter på: http://www.symbol.com/
environmental_compliance.
Deutsch: Für Kunden innerhalb der EU: Alle Produkte müssen am Ende ihrer Lebensdauer zum
Recycling an Symbol zurückgesandt werden. Informationen zur Rücksendung von Produkten
finden Sie unter http://www.symbol.com/environmental_compliance.
Eesti: EL klientidele: kõik tooted tuleb nende eluea lõppedes tagastada taaskasutamise
eesmärgil Symbol'ile. Lisainformatsiooni saamiseks toote tagastamise kohta külastage palun
aadressi: http://www.symbol.com/environmental_compliance.
Español: Para clientes en la Unión Europea: todos los productos deberán entregarse a Symbol
al final de su ciclo de vida para que sean reciclados. Si desea más información sobre cómo
devolver un producto, visite: http://www.symbol.com/environmental_compliance.
Français : Clients de l'Union Européenne : Tous les produits en fin de cycle de vie doivent être
retournés à Symbol pour recyclage. Pour de plus amples informations sur le retour de produits,
consultez : http://www.symbol.com/environmental_compliance.
Italiano: per i clienti dell'UE: tutti i prodotti che sono giunti al termine del rispettivo ciclo di
vita devono essere restituiti a Symbol al fine di consentirne il riciclaggio. Per informazioni sulle
modalità di restituzione, visitare il seguente sito Web: http://www.symbol.com/
environmental_compliance.
Magyar: Az EU-ban vásárlóknak: Minden tönkrement terméket a Symbol vállalathoz kell
eljuttatni újrahasznosítás céljából. A termék visszajuttatásának módjával kapcsolatos
tudnivalókért látogasson el a http://www.symbol.com/environmental_compliance weboldalra
Regulatory Information
Nederlands: Voor klanten in de EU: alle producten dienen aan het einde van hun levensduur
naar Symbol te worden teruggezonden voor recycling. Raadpleeg http://www.symbol.com/
environmental_compliance voor meer informatie over het terugzenden van producten.
Português: Para clientes da UE: todos os produtos no fim de vida devem ser devolvidos à
Symbol para reciclagem. Para obter informações sobre como devolver o produto, visite: http:/
/www.symbol.com/environmental_compliance.
Slovenski: Za kupce v EU: vsi izdelki se morajo po poteku življenjske dobe vrniti podjetju
Symbol za reciklažo. Za informacije o vraèilu izdelka obišèite: http://www.symbol.com/
environmental_compliance.
Suomi: Asiakkaat Euroopan unionin alueella: Kaikki tuotteet on palautettava kierrätettäväksi
Symbol-yhtiöön, kun tuotetta ei enää käytetä. Lisätietoja tuotteen palauttamisesta on
osoitteessa http://www.symbol.com/environmental_compliance.
5.15 TURKISH WEEE Statement of Compliance
EEE Yönetmeliğine Uygundur
5.16 Japan (VCCI) - Voluntary Control Council for Interference Class B
ITE
この装置は、情報処理装置等電波障害自主規制協議会 (VCCI)の基準に基づくク
ラス B 情報技術装置です。この装置は、家庭環境で使用することを目的としています
が、この装置がラジオやテレビジョン受信機に近接して使用されると、受信障害を引
き起こすことがあります。取扱説明書に従って正しい取り扱いをして下さい。
This is a Class B product based on the standard of the Voluntary Control Council for Interference from
Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a
domestic environment, it may cause radio interference. Install and use the equipment according to
the instruction manual.
47
48 AP-6521 Series Access Point Installation Guide
5.17 Korea Warning Statement for Class B ITE
기종별
B 급 기기
( 가정용 방송통신기기 )
사용자안내문
이 기기는 가정용 (B 급 ) 으로 전자파적합등록을
한 기기로서 주로 가정에서 사용하는 것을 목적
으로 하며 , 모든 지역에서 사용할 수 있습니다 .
Class B (Broadcasting
This device obtained EMC registration mainly for home use
Communication Device for Home (Class B) and may be used in all areas.
Use)
5.18 Other Countries
5.18.1 Australia
Use of 5 GHz RLAN’s in Australia is restricted in the following band 5.50 – 5.65 GHz.
5.18.2 Brazil
Regulatory declarations for - BRAZIL
Note: The certification mark applied to the AP-6521x is for Restrict Radiation Equipment. This
equipment operates on a secondary basis and does not have the right for protection against harmful
interference from other users including same equipment types. Also this equipment must not cause
interference to systems operating on primary basis.
For more information consult the website http://www.anatel.gov.br
Declarações Regulamentares para - Brasil
Nota: "A marca de certificação se aplica ao Transceptor, modelo AP-6521x. Este equipamento opera
em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de
estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.”
Para maiores informações sobre ANATEL consulte o site: http://www.anatel.gov.br
5.18.3 Chile
“Este equipo cumple con la Resolución No 403 de 2008, de la Subsecretaria de telecomunicaciones,
relativa a radiaciones electromagnéticas.”.
"This device complies with the Resolution Not 403 of 2008, of the Undersecretary of
telecommunications, relating to electromagnetic radiation.”
Regulatory Information
5.18.4 Mexico
Restrict Frequency Range to: 2.450 – 2.4835 GHz.
5.18.5 Taiwan
NOTICE!
According to: Administrative Regulations on Low Power Radio Waves Radiated Devices
Article 12
Without permission granted by the DGT, any company, enterprise, or user is not allowed to change
frequency, enhance transmitting power or alter original characteristic as well as performance to an
approved low power radio-frequency devices.
Article 14
The low power radio-frequency devices shall not influence aircraft security and interfere legal
communications; If found, the user shall cease operating immediately until no interference is
achieved.
The said legal communications means radio communications is operated in compliance with the
Telecommunications Act.
The low power radio-frequency devices must be susceptible with the interference from legal
communications or ISM radio wave radiated devices.
臺灣
低功率電波輻射性電機管理辦法
第十二條
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自
變更頻率、加大功率或變更原設計之特性及功能。
第十四條
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象
時,應立即停用,並改善至無干擾時方得繼續使用。
前項合法通信,指依電信規定作業之無線電通信。
低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干
擾。
49
50 AP-6521 Series Access Point Installation Guide
Wireless device operate in the frequency band of 5.25-5.35 GHz, limited for Indoor use only.
在 5.25-5.35 赫頻帶內操作之無線資訊傳輸設備,限於室內使用。
5.18.6 Korea
For radio equipment using 2400~2483.5MHz or 5725~5825MHz, the following expressions should be
displayed:
1. “This radio equipment can be interfered with during operation.”
당해 무선설비는 운용 중 전파혼신 가능성이 있음
2. “This radio equipment cannot provide a service relevant to human life safety, as it can be
crossed” through the user manual, etc.
당해 무선설비 는전파혼 신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없습니다
Motorola Solutions Enterprise Mobility
Support Center
Motorola Solutions Enterprise Mobility Support
Center
If you have a problem with your equipment, contact Enterprise Mobility support for your region.
Contact information is available by visiting http://supportcentral.motorola.com and after selecting
your region, click on the appropriate link under Support for Business.
When contacting Enterprise Mobility support, please provide the following information:
• Serial number of the unit
• Model number or product name
• Software type and version number
Motorola Solutions responds to calls by email, telephone or fax within the time limits set forth in
support agreements. If you purchased your Enterprise Mobility business product from a Motorola
Solutions business partner, contact that business partner for support.
6.1 Customer Support Web Sites
Motorola Solutions’s Support Central Web site, located at http://supportcentral.motorola.com
provides information and online assistance including developer tools, software downloads, product
manuals and online repair requests.
6.2 Manuals
http://support.symbol.com/support/product/manuals.do
51
52 AP-6521 Series Access Point Installation Guide
MOTOROLA SOLUTIONS INC.
1303 E. ALGONQUIN ROAD
SCHAUMBURG, IL 60196
http://www.motorolasolutions.com
72-155456-01 Revision B
May 2012

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Mode                       : UseNone
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : FrameMaker 8.0
Modify Date                     : 2012:04:30 08:01:50Z
Create Date                     : 2012:04:30 07:43:58Z
Format                          : application/pdf
Title                           : 6521 IG.book
Creator                         : fdq876
Document ID                     : uuid:5a87da1d-b5b8-40d6-931d-896604102b92
Instance ID                     : uuid:6afe7ecb-a03d-4951-a926-36d697c8672e
Page Count                      : 60
Author                          : fdq876
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UZ7AP6

Navigation menu