THB4002GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide Provided by Measuring Temperature The Smart Way
    2  Table Of Contents Warranty ..................................................................... 17 Descripon .................................................................... 3 Features ........................................................................ 4 Distance to Spot ........................................................... 4 Reset ............................................................................. 5 Indicators....................................................................... 5 Specicaons ................................................................ 7 Proper Applicaon and Operaon ............................... 9 Power Switch ................................................................ 11 Mounng Bracket ......................................................... 11 Maintenance ................................................................. 13 Laser Safety ................................................................... 16 Other Operaonal Consideraons ............................... 13 Cercaons ................................................................. 18 FCC Compliance Statement .......................................... 20 Bluetooth & Pairing ...................................................... 6 IC Warning ................................................................... 21
3     CAUTION! – This product is not intended for medical use or use on humans  Descripon The zippyYum GoTemp Model THB4002 is smart contactless thermometer featuring Bluetooth 4.0 Low Energy. GoTemp combines two precision thermome-ters: accurately calibrated noncontact infrared thermometer and a thermocouple port for penetraon probe. The noncontact mode can be used for quick scans of a surface temperature, while the probe mode is used to accurately measure internal temperatures. GoTemp is a baery operated device and can be recharged via the standard micro USB connector from any computer or 5V charger. A K-type thermocouple connect-or is used to connect the inseron probe. The interface of the device is minimal as it includes an illuminated push buon to provide ability to reset and give feedback about device status and a slide switch to turn ON and OFF Thank you for purchasing GoTemp. We are condent that you will be pleased with the quality and performance of this product. Please take a few moments to familiarize yourself with the operaon, features, and benets of this ne product.
4  Features •Contactless temperature measurement•Laser pointer to indicate the measured locaon •Accepts K-type thermocou-ples•Rechargeable baery •Interchangeable holders for iPhone 5, 6, 6+, and universal bracket for use on all other phone models  Distance to Spot The eld of view (Distance to Spot) is the area or poron of food product that is being measured thermally. The distance of the infrared thermometer from the target determines the dimension of this area. The further away from the target, the larger is the area being measured. The ideal working range of GoTemp is between 25 mm and 300 mm (1 and 12inch-es). The laser pointer helps to indicate the measurement spot. To ensure accurate measurements, the measured spot must ll or exceed the eld of view. Moving closer to the target produces more accurate measures
    5  Reset To reset GoTemp, press and hold the buon for 3 seconds. 5 orange blinks appear aer the reset.  Indicators GoTemp is equipped with two LEDs to indicate the device’s state. Please note that Amber color appears if both red and green LEDs are lit simultaneously. Indicator reects the device state and warns you if baery is geng low or there is not enough charge to power device. Green color indicates full baery, orange means that baery is low and red means baery is empty. Blinking light means the device is connected to a phone. You can always check the baery percentage and charging state on the phone’s display. Refer to the below table for detailed indicator states
6 Baery Level Connected? Charging? LED State Not enough charge NO NO OFF Not enough charge NO YES Orange solid Not enough charge YES NO Red blink Not enough charge YES YES Orange blink Enough charge NO NO OFF Enough charge NO YES Green solid Enough charge YES NO Green blink Enough charge YES YES Green blink  Bluetooth & Pairing GoTemp must be paired with smartphone before the rst use.  Every GoTemp device has a unique idener printed on the back, it is known as MAC. The Mobile App will automacally connect to the available GoTemp if there is only one GoTemp found in the range, otherwise, a list will pop up for the user to select the device to be used. The names of available GoTemp devices show up as  “GOTEMP_XX”, with XX denong the last two digits of MAC. Once the correct GoTemp is chosen, the indicator starts blinking and a text box appears on mobile app to enter the PIN. Enter “123456” as pairing PIN.
7  Specicaons Model: THB4002 Operang Condions Parameter Value Storage Temperature  -10 - 45°C (14 - 113°F) Operang Temperature 10 -  40°C (50 - 104°F) Humidity 10 - 90% RH Charging Current <100mA Charging Voltage 5V Baery Parameter Value Capacity 400 mAh Voltage 3.7V Lifeme 360 hours Standby 16 hours measuring Laser Parameter Value Peak Wavelength  650nm Opcal Power  <1mW Bluetooth Power: 0dBm
8 Probe Temperature Parameter Condions Value Measurement range  -10 - 120°C (14 - 250°F) Resoluon 0.25°C (0.25°F) Accuracy at room temperature Object temperature: -10- 120°C ±1°C (2°F) Repeatability Within accuracy Response Time 1 second Infrared Temperature Parameter Conditions Value Measurement range  -10 - 120°C (14 - 250°F) Resolution 0.1°C (0.1°F) Typical Measurement Distance 25 - 300mm (1-12”) Distance to Spot 12:1 Accuracy at room  temperature (25 °C) Object temperature:    0 - 60°C ±0.5°C (2°F) Accuracy at room  temperature (25 °C) Object temperature:  < 0 °C or > 60°C ±1°C (4°F) Repeatability Within accuracy Response Time 1 second
9  AVOID STORING THE UNIT IN EXTREME TEMPERATURE CONDITIONS. DO NOT STORE INFRARED THERMOMETERS BELOW FREEZING TEMPERATURE OR WHERE THE RADIANT TEMPERATURE MAY EXCEED 48.9°C (120°F)  Proper Applicaon and Operaon The IR thermometer only measures surface temperature, crical temperatures must be veried with an internal temperature probe. Use Probe For Internal Temper-ature To take a spot temperature measurement, aim the sensor at the desired target and acvate the unit. The spot size measured is indicated in secon “Distance to Spot” . Mind The Meas-ured Spot The IR thermometer cannot measure through transparent surfaces such as glass and plasc. It will measure the surface temperature of the glass, or plasc instead. Remove Trans-parent Covers Before Measur-ing Steam, dust, smoke and/or vapors can prevent accurate measurement by obstrucng the unit’s opcs. Please refer to maintenance secon for cleaning in case any of these condions happened . Keep Unit Clean Infrared thermometers are not designed for use in high humidity-condensing environments. Do Not Measure in High humidity For the most accurate temperature measurements, aim the infrared thermometer perpendicular to the target. If possible, the eld of view should be an even, horizontal plane (the aest surface of a food product being meas-ured). Keep Device Perpendicular To Measured Sur-face
10 The IR thermometer is not recommended for use in measur-ing reecve surfaces such as stainless steel and/or alumi-num wrapping. The temperature of a reecve object may be measured if the surface is coated with a mae material . Avoid Measur-ing Shiny Surfaces The infrared emissivity of a target is a funcon of the reec-ve properes of its surface. GoTemp Emissivity is preset to 0.95 which is opmal for most Food Products. If the emissivity of the target material is quesonable, determine its value by referring to the emissivity table. GoTemp emissivity can be changed from 0.1 to 1.0 in 0.01 steps, refer to instrucon in the mobile app to modify emissivity.  Most Food Products Do Not Require Change of Emissivity GoTemp is designed to work between 10 °C and 40°C (50 - 104°F). In case a change in temperature happened like walking in/out of walk-in freezer, the unit must not be used for at least 15 minutes (precondioned). Failure to precondion the unit may result in thermal shock and/or inaccurate measurements. Precondion For 15 Minutes If Ambient Temperature Changed GoTemp can display temperatures in Celsius or Fahrenheit, refer to instrucon in the mobile app to change scale. Select Desired Display Unit
11  Power Switch Power Switch located on the boom of GoTemp is turned OFF to minimize baery drain. Use a small plasc pin to switch the power buon ON before operaon. Five orange blinks appear at power up. Make sure the LEDs are working, otherwise, plug charger and expect ashing orange light. Power buon can be turned o if GoTemp is not used for long me, which will save baery and extend its life.  Mounng Brackets Four mounng brackets are provided for iPhone 5/5s, iPhone 6, iPhone 6+ and adjustable bracket for use on all other phones. Aer turning the switch ON, posion the bracket and push it in the guiding grooves to snap in place. Push the bracket in opposite direcon to remove.
12
13  Maintenance Field Verification of Accuracy GoTemp is pre-calibrated. However, their accuracy can be veried in the eld by using the following simple procedure. It is suggested that the accuracy of the in-strument be veried on a regular basis. For food applicaons, the IR thermometer accuracy should be veried at the rele-vant crical food temperatures [5°C (41°F); 60/71.1°C (140°/165°F)]. A two-point vericaon is recommended. Materials needed: 1. Aluminum container (beverage can).2. Mae-black spray paint or mae-black self-adhering paper appliqué. Masking tape may also be used.3. Temperature-standard thermometer. Other Operaonal Consideraons GoTemp is protected from the following: •EMI (Electro Magnec Interference) from inducon heaters and microwave ovens •Electrostac discharge•Should the unit become damaged, check the accuracy of the unit by performing the vericaon process recommended in this manual. If the unit is out of calibra-on, do not rely on it for crical temperature measurements. Contact a zip-pyYum for informaon
 14 Preparaon: Prepare container by painng or applying the mae material to the outer sur-face. Vericaon Procedure: 1. Fill the aluminum container with refrigerated water, insert the temperature standard thermometer and allow the can and temperature-standard ther-mometer to come to equilibrium.2. Take a reading with the IR thermometer. Do not exceed the spot size of the IRthermometer as indicated on the unit.3. Compare the temperature reading of the IR unit with the temperature stand-ard thermometer *.4. Repeat this procedure using hot water.* If the temperature deviaon exceeds accuracy limit, return the unit for repair.Preparation Verification
15  To ensure an accurate temperature reading, the lens of the IR unit should be free of dirt, dust, moisture, fog, smoke and debris.  To clean the lens, you would need two lint free coon swabs. Moist a coon swab and insert it in the aperture to scrub the deep lens then repeat the same using the dry coon swab. To clean the unit itself, wipe it down with a moist cloth using water based mild detergent.      Warning! – Do not submerse the unit or wash in dishwasher Cleaning Instructions
16  Laser Safety Laser pointer in GoTemp is FDA 21 CFR 1040.10, subchapter J compliant. Please refer to laser specicaons in specicaon secon     Warning!  1. Avoid direct exposure of human eyes to laser light. Eye damage may result.2. Never point the laser light at another person.3. Keep the laser-equipped unit out of the reach of children.4. Avoid indirect exposure via reecve surfaces, such as glass and mirrors.
17 ZippyYum LLC warrants that this product, at the me of its sale by ZippyYum, is free of defects in material and workmanship and component failures under normal and proper use for a period of one (1) year from date of delivery and applies world-wide.  ZippyYum‘s only obligaon is to correct such defects by repair or replacement, at its opon, if within such one year period the product is returned prepaid.  There are no other or implied warranes of any kind, including merchantability and tness for a parcular purpose.  ZippyYum is not liable for incidental, indi-rect, special, or consequenal damages, including without limitaon, damage to, or loss of use of, any equipment, lost sales or prots or delay or failure to per-form this warranty obligaon. ZippyYum’s liability on any claim for damages arising out of in connecon with the manufacture, sales, installaon delivery, or use of the product shall never exceed the purchase price of the product. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. In line with ZippyYum’s policy of connuous development ZippyYum reserves the right to alter any specicaons without noce.  Warranty
18  Cercaons GoTemp conforms to the following standards: •UL listed for UL2333 – Standard For Safety - Infrared Thermometers •UL EPH Classied for ANSI/NSF 2 – standard for •FCC CFR47 Part 15 Secon 15.247:2014•Industry Canada RSS-247 •European Union Direcves◦1999/5/EC - Radio & Telecommunicaons Terminal Equipment (R&TTE) Direcve ◦2014/35/EU - Low Voltage (LVD) Direcve ◦2014/30/EU - Electromagnec Compability (EMC) Direcve◦2011/65/EU - EU Restricon of Hazardous Substances (RoHS) Direcve ◦2012/19/EU - Waste Electrical and Electronic Equipment (WEEE) Direcve •ACME (Australia) Standards◦AS/NZS 4268:2012+ A1:2013 ◦EN 61000-6-1:2007◦EN 61000-6-3:2007 +A1:2011 ◦EN 61000-3-2:2014◦EN 61000-3-3:2013
19 FABRICATED FOOD SERVICE  EQUIPMENT NSF/ANSI 2 SA44549 INFRARED THERMOMETER E481655 Industry Canada Industrie Canada IC: 21861-THB4002 RCM Cert. No: POC16104019 FCC ID:2AE6ATHB4002
    20  THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARM-FUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE   RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIP-MENT. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are de-signed to provide reasonable protecon against harmful interference in a residen-al installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon, which can be deter-mined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. FCC Part 15.19 Warning Statement  FCC Compliance FCC Part 15.21 Warning Statement FCC Part 15.105 Warning Statement
    21  —Increase the separaon between the equipment and receiver. —Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. RF warning statement The device has been evaluated to meet general RF exposure requirement. The device can beused in portable exposure condion without restricon. IC Warning This device complies with Industry Canada licence-exempt RSS standard(s). Opera-on is subject to the following two condions: (1) this device may not cause inter-ference, and (2) this device must accept any interference, including interference that may cause undesired operaon of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitaon est autorisée aux deux condions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d'en compromere le fonconnement. RF warning statement: The device has been evaluated to meet general RF exposure requirement. Le disposif de a été évalués à répondre général RF exposion exigence.
    22  ZippyYum LLC  275 Centennial Way, #105,   Tusn, CA 92780  Phone: +1 (888) 636-7557 Fax: +1 (866) 434-0883 www.zippyyum.com www.mangoe.com