ZippyYum THB4002 GoTemp, SubTemp User Manual

ZippyYum LLC GoTemp, SubTemp

User Manual

THB4002
GoTemp
Food Infrared Thermometer
With Laser Sighting And Thermocouple Jack
User Guide
Provided by
Measuring Temperature
The Smart Way
2
Table Of Contents
Warranty ..................................................................... 17
Descripon .................................................................... 3
Features ........................................................................ 4
Distance to Spot ........................................................... 4
Reset ............................................................................. 5
Indicators....................................................................... 5
Specicaons ................................................................ 7
Proper Applicaon and Operaon ............................... 9
Power Switch ................................................................ 11
Mounng Bracket ......................................................... 11
Maintenance ................................................................. 13
Laser Safety ................................................................... 16
Other Operaonal Consideraons ............................... 13
Cercaons ................................................................. 18
FCC Compliance Statement .......................................... 20
Bluetooth & Pairing ...................................................... 6
IC Warning ................................................................... 21
3
CAUTION! – This product is not intended for medical use or use on humans
Descripon
The zippyYum GoTemp Model THB4002 is smart contactless thermometer
featuring Bluetooth 4.0 Low Energy. GoTemp combines two precision thermome-
ters: accurately calibrated noncontact infrared thermometer and a thermocouple
port for penetraon probe. The noncontact mode can be used for quick scans of a
surface temperature, while the probe mode is used to accurately measure internal
temperatures.
GoTemp is a baery operated device and can be recharged via the standard micro
USB connector from any computer or 5V charger. A K-type thermocouple connect-
or is used to connect the inseron probe.
The interface of the device is minimal as it includes an illuminated push buon to
provide ability to reset and give feedback about device status and a slide switch to
turn ON and OFF
Thank you for purchasing GoTemp. We are condent that you will be pleased
with the quality and performance of this product. Please take a few moments to
familiarize yourself with the operaon, features, and benets of this ne product.
4
Features
Contactless temperature
measurement
Laser pointer to indicate
the measured locaon
Accepts K-type thermocou-
ples
Rechargeable baery
Interchangeable holders
for iPhone 5, 6, 6+, and
universal bracket for use on
all other phone models
Distance to Spot
The eld of view (Distance to Spot) is the area or poron of food product that is
being measured thermally. The distance of the infrared thermometer from the
target determines the dimension of this area. The further away from the target, the
larger is the area being measured.
The ideal working range of GoTemp is between 25 mm and 300 mm (1 and 12inch-
es). The laser pointer helps to indicate the measurement spot. To ensure accurate
measurements, the measured spot must ll or exceed the eld of view.
Moving closer to the target produces more accurate measures
5
Reset
To reset GoTemp, press and hold the buon for 3 seconds. 5 orange blinks appear
aer the reset.
Indicators
GoTemp is equipped with two LEDs to indicate the devices state. Please note that
Amber color appears if both red and green LEDs are lit simultaneously.
Indicator reects the device state and warns you if baery is geng low or there is
not enough charge to power device. Green color indicates full baery, orange
means that baery is low and red means baery is empty. Blinking light means the
device is connected to a phone.
You can always check the baery percentage and charging state on the phones
display.
Refer to the below table for detailed indicator states
6
Baery Level Connected? Charging? LED State
Not enough charge NO NO OFF
Not enough charge NO YES Orange solid
Not enough charge YES NO Red blink
Not enough charge YES YES Orange blink
Enough charge NO NO OFF
Enough charge NO YES Green solid
Enough charge YES NO Green blink
Enough charge YES YES Green blink
Bluetooth & Pairing
GoTemp must be paired with smartphone before the rst use. Every GoTemp
device has a unique idener printed on the back, it is known as MAC.
The Mobile App will automacally connect to the
available GoTemp if there is only one GoTemp found
in the range, otherwise, a list will pop up for the user
to select the device to be used. The names of available
GoTemp devices show up as GOTEMP_XX”, with XX
denong the last two digits of MAC.
Once the correct GoTemp is chosen, the indicator
starts blinking and a text box appears on mobile app to
enter the PIN. Enter “123456” as pairing PIN.
7
Specicaons
Model: THB4002
Operang Condions
Parameter Value
Storage Temperature -10 - 45°C (14 - 113°F)
Operang Temperature 10 - 40°C (50 - 104°F)
Humidity 10 - 90% RH
Charging Current <100mA
Charging Voltage 5V
Baery
Parameter Value
Capacity 400 mAh
Voltage 3.7V
Lifeme 360 hours Standby
16 hours measuring
Laser
Parameter Value
Peak Wavelength 650nm
Opcal Power <1mW
Bluetooth Power: 0dBm
8
Probe Temperature
Parameter Condions Value
Measurement range -10 - 120°C (14 - 250°F)
Resoluon 0.25°C (0.25°F)
Accuracy at room
temperature
Object temperature:
-10- 120°C
±1°C (2°F)
Repeatability Within accuracy
Response Time 1 second
Infrared Temperature
Parameter Conditions Value
Measurement range -10 - 120°C (14 - 250°F)
Resolution 0.1°C (0.1°F)
Typical Measurement
Distance
25 - 300mm (1-12”)
Distance to Spot 12:1
Accuracy at room
temperature (25 °C)
Object temperature:
0 - 60°C
±0.5°C (2°F)
Accuracy at room
temperature (25 °C)
Object temperature:
< 0 °C or > 60°C
±1°C (4°F)
Repeatability Within accuracy
Response Time 1 second
9
AVOID STORING THE UNIT IN EXTREME TEMPERATURE CONDITIONS. DO NOT
STORE INFRARED THERMOMETERS BELOW FREEZING TEMPERATURE OR WHERE
THE RADIANT TEMPERATURE MAY EXCEED 48.9°C (120°F)
Proper Applicaon and Operaon
The IR thermometer only measures surface temperature,
crical temperatures must be veried with an internal
temperature probe.
Use Probe For
Internal Temper-
ature
To take a spot temperature measurement, aim the sensor
at the desired target and acvate the unit. The spot size
measured is indicated in secon Distance to Spot .
Mind The Meas-
ured Spot
The IR thermometer cannot measure through transparent
surfaces such as glass and plasc. It will measure the
surface temperature of the glass, or plasc instead.
Remove Trans-
parent Covers
Before Measur-
ing
Steam, dust, smoke and/or vapors can prevent accurate
measurement by obstrucng the units opcs. Please
refer to maintenance secon for cleaning in case any of
these condions happened .
Keep Unit Clean
Infrared thermometers are not designed for use in high
humidity-condensing environments.
Do Not Measure
in High humidity
For the most accurate temperature measurements, aim
the infrared thermometer perpendicular to the target. If
possible, the eld of view should be an even, horizontal
plane (the aest surface of a food product being meas-
ured).
Keep Device
Perpendicular To
Measured Sur-
face
10
The IR thermometer is not recommended for use in measur-
ing reecve surfaces such as stainless steel and/or alumi-
num wrapping. The temperature of a reecve object may
be measured if the surface is coated with a mae material .
Avoid Measur-
ing Shiny
Surfaces
The infrared emissivity of a target is a funcon of the reec-
ve properes of its surface.
GoTemp Emissivity is preset to 0.95 which is opmal for
most Food Products.
If the emissivity of the target material is quesonable,
determine its value by referring to the emissivity table.
GoTemp emissivity can be changed from 0.1 to 1.0 in 0.01
steps, refer to instrucon in the mobile app to modify
emissivity.
Most Food
Products Do
Not Require
Change of
Emissivity
GoTemp is designed to work between 10 °C and 40°C (50 -
104°F). In case a change in temperature happened like
walking in/out of walk-in freezer, the unit must not be used
for at least 15 minutes (precondioned).
Failure to precondion the unit may result in thermal shock
and/or inaccurate measurements.
Precondion
For 15 Minutes
If Ambient
Temperature
Changed
GoTemp can display temperatures in Celsius or Fahrenheit,
refer to instrucon in the mobile app to change scale.
Select Desired
Display Unit
11
Power Switch
Power Switch located on the boom of GoTemp is
turned OFF to minimize baery drain. Use a small
plasc pin to switch the power buon ON before
operaon.
Five orange blinks appear at power up. Make sure
the LEDs are working, otherwise, plug charger and
expect ashing orange light.
Power buon can be turned o if GoTemp is not
used for long me, which will save baery and
extend its life.
Mounng Brackets
Four mounng brackets are provided for iPhone 5/5s, iPhone 6, iPhone 6+ and
adjustable bracket for use on all other phones.
Aer turning the switch ON, posion the bracket and push it in the guiding grooves
to snap in place. Push the bracket in opposite direcon to remove.
12
13
Maintenance
Field Verification of Accuracy
GoTemp is pre-calibrated. However, their accuracy can be veried in the eld by
using the following simple procedure. It is suggested that the accuracy of the in-
strument be veried on a regular basis.
For food applicaons, the IR thermometer accuracy should be veried at the rele-
vant crical food temperatures [5°C (41°F); 60/71.1°C (140°/165°F)]. A two-point
vericaon is recommended.
Materials needed:
1. Aluminum container (beverage can).
2. Mae-black spray paint or mae-black self-adhering paper appliqué. Masking
tape may also be used.
3. Temperature-standard thermometer.
Other Operaonal Consideraons
GoTemp is protected from the following:
EMI (Electro Magnec Interference) from inducon heaters and microwave
ovens
Electrostac discharge
Should the unit become damaged, check the accuracy of the unit by performing
the vericaon process recommended in this manual. If the unit is out of calibra-
on, do not rely on it for crical temperature measurements. Contact a zip-
pyYum for informaon
14
Preparaon:
Prepare container by painng or applying the mae material to the outer sur-
face.
Vericaon Procedure:
1. Fill the aluminum container with refrigerated water, insert the temperature
standard thermometer and allow the can and temperature-standard ther-
mometer to come to equilibrium.
2. Take a reading with the IR thermometer. Do not exceed the spot size of the IR
thermometer as indicated on the unit.
3. Compare the temperature reading of the IR unit with the temperature stand-
ard thermometer *.
4. Repeat this procedure using hot water.
* If the temperature deviaon exceeds accuracy limit, return the unit for repair.
Preparation Verification
15
To ensure an accurate temperature reading, the lens of the IR unit should be free
of dirt, dust, moisture, fog, smoke and debris.
To clean the lens, you would need two lint free coon swabs. Moist a coon swab
and insert it in the aperture to scrub the deep lens then repeat the same using the
dry coon swab.
To clean the unit itself, wipe it down with a moist cloth using water based mild
detergent.
Warning! – Do not submerse the unit or wash in dishwasher
Cleaning Instructions
16
Laser Safety
Laser pointer in GoTemp is FDA 21 CFR 1040.10, subchapter J compliant. Please
refer to laser specicaons in specicaon secon
Warning!
1. Avoid direct exposure of human eyes to laser light. Eye damage may result.
2. Never point the laser light at another person.
3. Keep the laser-equipped unit out of the reach of children.
4. Avoid indirect exposure via reecve surfaces, such as glass and mirrors.
17
ZippyYum LLC warrants that this product, at the me of its sale by ZippyYum, is free
of defects in material and workmanship and component failures under normal and
proper use for a period of one (1) year from date of delivery and applies world-
wide.
ZippyYums only obligaon is to correct such defects by repair or replacement, at
its opon, if within such one year period the product is returned prepaid.
There are no other or implied warranes of any kind, including merchantability
and tness for a parcular purpose. ZippyYum is not liable for incidental, indi-
rect, special, or consequenal damages, including without limitaon, damage to,
or loss of use of, any equipment, lost sales or prots or delay or failure to per-
form this warranty obligaon.
ZippyYums liability on any claim for damages arising out of in connecon with the
manufacture, sales, installaon delivery, or use of the product shall never exceed
the purchase price of the product. The remedies provided herein are the exclusive
remedies under this warranty, whether based on contract, tort or otherwise.
In line with ZippyYums policy of connuous development ZippyYum reserves the
right to alter any specicaons without noce.
Warranty
18
Cercaons
GoTemp conforms to the following standards:
UL listed for UL2333 – Standard For Safety - Infrared Thermometers
UL EPH Classied for ANSI/NSF 2 standard for
FCC CFR47 Part 15 Secon 15.247:2014
Industry Canada RSS-247
European Union Direcves
1999/5/EC - Radio & Telecommunicaons Terminal Equipment (R&TTE)
Direcve
2014/35/EU - Low Voltage (LVD) Direcve
2014/30/EU - Electromagnec Compability (EMC) Direcve
2011/65/EU - EU Restricon of Hazardous Substances (RoHS) Direcve
2012/19/EU - Waste Electrical and Electronic Equipment (WEEE) Direcve
ACME (Australia) Standards
AS/NZS 4268:2012+ A1:2013
EN 61000-6-1:2007
EN 61000-6-3:2007 +A1:2011
EN 61000-3-2:2014
EN 61000-3-3:2013
19
FABRICATED FOOD
SERVICE
EQUIPMENT
NSF/ANSI 2
SA44549
INFRARED
THERMOMETER
E481655
Industry Canada
Industrie Canada
IC: 21861-THB4002
RCM Cert.
No:
POC16104019
FCC ID:2AE6ATHB4002
20
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT
TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARM-
FUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS
NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH
MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIP-
MENT.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are de-
signed to provide reasonable protecon against harmful interference in a residen-
al installaon. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instrucons, may cause
harmful interference to radio communicaons. However, there is no guarantee
that interference will not occur in a parcular installaon. If this equipment does
cause harmful interference to radio or television recepon, which can be deter-
mined by turning the equipment o and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
FCC Part 15.19 Warning Statement
FCC Compliance
FCC Part 15.21 Warning Statement
FCC Part 15.105 Warning Statement
21
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit dierent from that to which
the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
RF warning statement
The device has been evaluated to meet general RF exposure requirement. The
device can beused in portable exposure condion without restricon.
IC Warning
This device complies with Industry Canada licence-exempt RSS standard(s). Opera-
on is subject to the following two condions: (1) this device may not cause inter-
ference, and (2) this device must accept any interference, including interference
that may cause undesired operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitaon est autorisée aux deux condions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'ulisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est suscepble d'en compromere le fonconnement.
RF warning statement:
The device has been evaluated to meet general RF exposure requirement.
Le disposif de a été évalués à répondre général RF exposion exigence.
22
ZippyYum LLC
275 Centennial Way, #105,
Tusn, CA 92780
Phone: +1 (888) 636-7557
Fax: +1 (866) 434-0883
www.zippyyum.com
www.mangoe.com