Measuring Temperature
The Smart Way
2
Table Of Contents
Warranty ..................................................................... 17
Descripon .................................................................... 3
Features ........................................................................ 4
Distance to Spot ........................................................... 4
Reset ............................................................................. 5
Indicators....................................................................... 5
Specicaons ................................................................ 7
Proper Applicaon and Operaon ............................... 9
Power Switch ................................................................ 11
Mounng Bracket ......................................................... 11
Maintenance ................................................................. 13
Laser Safety ................................................................... 16
Other Operaonal Consideraons ............................... 13
Cercaons ................................................................. 18
FCC Compliance Statement .......................................... 20
Bluetooth & Pairing ...................................................... 6
IC Warning ................................................................... 21
3
CAUTION! – This product is not intended for medical use or use on humans
Descripon
The zippyYum GoTemp Model THB4002 is smart contactless thermometer
featuring Bluetooth 4.0 Low Energy. GoTemp combines two precision thermome-
ters: accurately calibrated noncontact infrared thermometer and a thermocouple
port for penetraon probe. The noncontact mode can be used for quick scans of a
surface temperature, while the probe mode is used to accurately measure internal
temperatures.
GoTemp is a baery operated device and can be recharged via the standard micro
USB connector from any computer or 5V charger. A K-type thermocouple connect-
or is used to connect the inseron probe.
The interface of the device is minimal as it includes an illuminated push buon to
provide ability to reset and give feedback about device status and a slide switch to
turn ON and OFF
Thank you for purchasing GoTemp. We are condent that you will be pleased
with the quality and performance of this product. Please take a few moments to
familiarize yourself with the operaon, features, and benets of this ne product.
4
Features
•Contactless temperature
measurement
•Laser pointer to indicate
the measured locaon
•Accepts K-type thermocou-
ples
•Rechargeable baery
•Interchangeable holders
for iPhone 5, 6, 6+, and
universal bracket for use on
all other phone models
Distance to Spot
The eld of view (Distance to Spot) is the area or poron of food product that is
being measured thermally. The distance of the infrared thermometer from the
target determines the dimension of this area. The further away from the target, the
larger is the area being measured.
The ideal working range of GoTemp is between 25 mm and 300 mm (1 and 12inch-
es). The laser pointer helps to indicate the measurement spot. To ensure accurate
measurements, the measured spot must ll or exceed the eld of view.
Moving closer to the target produces more accurate measures
5
Reset
To reset GoTemp, press and hold the buon for 3 seconds. 5 orange blinks appear
aer the reset.
Indicators
GoTemp is equipped with two LEDs to indicate the device’s state. Please note that
Amber color appears if both red and green LEDs are lit simultaneously.
Indicator reects the device state and warns you if baery is geng low or there is
not enough charge to power device. Green color indicates full baery, orange
means that baery is low and red means baery is empty. Blinking light means the
device is connected to a phone.
You can always check the baery percentage and charging state on the phone’s
display.
Refer to the below table for detailed indicator states
6
Baery Level Connected? Charging? LED State
Not enough charge NO NO OFF
Not enough charge NO YES Orange solid
Not enough charge YES NO Red blink
Not enough charge YES YES Orange blink
Enough charge NO NO OFF
Enough charge NO YES Green solid
Enough charge YES NO Green blink
Enough charge YES YES Green blink
Bluetooth & Pairing
GoTemp must be paired with smartphone before the rst use. Every GoTemp
device has a unique idener printed on the back, it is known as MAC.
The Mobile App will automacally connect to the
available GoTemp if there is only one GoTemp found
in the range, otherwise, a list will pop up for the user
to select the device to be used. The names of available
GoTemp devices show up as “GOTEMP_XX”, with XX
denong the last two digits of MAC.
Once the correct GoTemp is chosen, the indicator
starts blinking and a text box appears on mobile app to
enter the PIN. Enter “123456” as pairing PIN.
7
Specicaons
Model: THB4002
Operang Condions
Parameter Value
Storage Temperature -10 - 45°C (14 - 113°F)
Operang Temperature 10 - 40°C (50 - 104°F)
Humidity 10 - 90% RH
Charging Current <100mA
Charging Voltage 5V
Baery
Parameter Value
Capacity 400 mAh
Voltage 3.7V
Lifeme 360 hours Standby
16 hours measuring
Laser
Parameter Value
Peak Wavelength 650nm
Opcal Power <1mW
Bluetooth Power: 0dBm
8
Probe Temperature
Parameter Condions Value
Measurement range -10 - 120°C (14 - 250°F)
Resoluon 0.25°C (0.25°F)
Accuracy at room
temperature
Object temperature:
-10- 120°C
±1°C (2°F)
Repeatability Within accuracy
Response Time 1 second
Infrared Temperature
Parameter Conditions Value
Measurement range -10 - 120°C (14 - 250°F)
Resolution 0.1°C (0.1°F)
Typical Measurement
Distance
25 - 300mm (1-12”)
Distance to Spot 12:1
Accuracy at room
temperature (25 °C)
Object temperature:
0 - 60°C
±0.5°C (2°F)
Accuracy at room
temperature (25 °C)
Object temperature:
< 0 °C or > 60°C
±1°C (4°F)
Repeatability Within accuracy
Response Time 1 second
9
AVOID STORING THE UNIT IN EXTREME TEMPERATURE CONDITIONS. DO NOT
STORE INFRARED THERMOMETERS BELOW FREEZING TEMPERATURE OR WHERE
THE RADIANT TEMPERATURE MAY EXCEED 48.9°C (120°F)
Proper Applicaon and Operaon
The IR thermometer only measures surface temperature,
crical temperatures must be veried with an internal
temperature probe.
Use Probe For
Internal Temper-
ature
To take a spot temperature measurement, aim the sensor
at the desired target and acvate the unit. The spot size
measured is indicated in secon “Distance to Spot” .
Mind The Meas-
ured Spot
The IR thermometer cannot measure through transparent
surfaces such as glass and plasc. It will measure the
surface temperature of the glass, or plasc instead.
Remove Trans-
parent Covers
Before Measur-
ing
Steam, dust, smoke and/or vapors can prevent accurate
measurement by obstrucng the unit’s opcs. Please
refer to maintenance secon for cleaning in case any of
these condions happened .
Keep Unit Clean
Infrared thermometers are not designed for use in high
humidity-condensing environments.
Do Not Measure
in High humidity
For the most accurate temperature measurements, aim
the infrared thermometer perpendicular to the target. If
possible, the eld of view should be an even, horizontal
plane (the aest surface of a food product being meas-
ured).
Keep Device
Perpendicular To
Measured Sur-
face
10
The IR thermometer is not recommended for use in measur-
ing reecve surfaces such as stainless steel and/or alumi-
num wrapping. The temperature of a reecve object may
be measured if the surface is coated with a mae material .
Avoid Measur-
ing Shiny
Surfaces
The infrared emissivity of a target is a funcon of the reec-
ve properes of its surface.
GoTemp Emissivity is preset to 0.95 which is opmal for
most Food Products.
If the emissivity of the target material is quesonable,
determine its value by referring to the emissivity table.
GoTemp emissivity can be changed from 0.1 to 1.0 in 0.01
steps, refer to instrucon in the mobile app to modify
emissivity.
Most Food
Products Do
Not Require
Change of
Emissivity
GoTemp is designed to work between 10 °C and 40°C (50 -
104°F). In case a change in temperature happened like
walking in/out of walk-in freezer, the unit must not be used
for at least 15 minutes (precondioned).
Failure to precondion the unit may result in thermal shock
and/or inaccurate measurements.
Precondion
For 15 Minutes
If Ambient
Temperature
Changed
GoTemp can display temperatures in Celsius or Fahrenheit,
refer to instrucon in the mobile app to change scale.
Select Desired
Display Unit
11
Power Switch
Power Switch located on the boom of GoTemp is
turned OFF to minimize baery drain. Use a small
plasc pin to switch the power buon ON before
operaon.
Five orange blinks appear at power up. Make sure
the LEDs are working, otherwise, plug charger and
expect ashing orange light.
Power buon can be turned o if GoTemp is not
used for long me, which will save baery and
extend its life.
Mounng Brackets
Four mounng brackets are provided for iPhone 5/5s, iPhone 6, iPhone 6+ and
adjustable bracket for use on all other phones.
Aer turning the switch ON, posion the bracket and push it in the guiding grooves
to snap in place. Push the bracket in opposite direcon to remove.
12
13
Maintenance
Field Verification of Accuracy
GoTemp is pre-calibrated. However, their accuracy can be veried in the eld by
using the following simple procedure. It is suggested that the accuracy of the in-
strument be veried on a regular basis.
For food applicaons, the IR thermometer accuracy should be veried at the rele-
vant crical food temperatures [5°C (41°F); 60/71.1°C (140°/165°F)]. A two-point
vericaon is recommended.
Materials needed:
1. Aluminum container (beverage can).
2. Mae-black spray paint or mae-black self-adhering paper appliqué. Masking
tape may also be used.
3. Temperature-standard thermometer.
Other Operaonal Consideraons
GoTemp is protected from the following:
•EMI (Electro Magnec Interference) from inducon heaters and microwave
ovens
•Electrostac discharge
•Should the unit become damaged, check the accuracy of the unit by performing
the vericaon process recommended in this manual. If the unit is out of calibra-
on, do not rely on it for crical temperature measurements. Contact a zip-
pyYum for informaon
14
Preparaon:
Prepare container by painng or applying the mae material to the outer sur-
face.
Vericaon Procedure:
1. Fill the aluminum container with refrigerated water, insert the temperature
standard thermometer and allow the can and temperature-standard ther-
mometer to come to equilibrium.
2. Take a reading with the IR thermometer. Do not exceed the spot size of the IR
thermometer as indicated on the unit.
3. Compare the temperature reading of the IR unit with the temperature stand-
ard thermometer *.
4. Repeat this procedure using hot water.
* If the temperature deviaon exceeds accuracy limit, return the unit for repair.
Preparation Verification
15
To ensure an accurate temperature reading, the lens of the IR unit should be free
of dirt, dust, moisture, fog, smoke and debris.
To clean the lens, you would need two lint free coon swabs. Moist a coon swab
and insert it in the aperture to scrub the deep lens then repeat the same using the
dry coon swab.
To clean the unit itself, wipe it down with a moist cloth using water based mild
detergent.
Warning! – Do not submerse the unit or wash in dishwasher
Cleaning Instructions
16
Laser Safety
Laser pointer in GoTemp is FDA 21 CFR 1040.10, subchapter J compliant. Please
refer to laser specicaons in specicaon secon
Warning!
1. Avoid direct exposure of human eyes to laser light. Eye damage may result.
2. Never point the laser light at another person.
3. Keep the laser-equipped unit out of the reach of children.
4. Avoid indirect exposure via reecve surfaces, such as glass and mirrors.
17
ZippyYum LLC warrants that this product, at the me of its sale by ZippyYum, is free
of defects in material and workmanship and component failures under normal and
proper use for a period of one (1) year from date of delivery and applies world-
wide.
ZippyYum‘s only obligaon is to correct such defects by repair or replacement, at
its opon, if within such one year period the product is returned prepaid.
There are no other or implied warranes of any kind, including merchantability
and tness for a parcular purpose. ZippyYum is not liable for incidental, indi-
rect, special, or consequenal damages, including without limitaon, damage to,
or loss of use of, any equipment, lost sales or prots or delay or failure to per-
form this warranty obligaon.
ZippyYum’s liability on any claim for damages arising out of in connecon with the
manufacture, sales, installaon delivery, or use of the product shall never exceed
the purchase price of the product. The remedies provided herein are the exclusive
remedies under this warranty, whether based on contract, tort or otherwise.
In line with ZippyYum’s policy of connuous development ZippyYum reserves the
right to alter any specicaons without noce.
Warranty
18
Cercaons
GoTemp conforms to the following standards:
•UL listed for UL2333 – Standard For Safety - Infrared Thermometers
•UL EPH Classied for ANSI/NSF 2 – standard for
•FCC CFR47 Part 15 Secon 15.247:2014
•Industry Canada RSS-247
•European Union Direcves
◦1999/5/EC - Radio & Telecommunicaons Terminal Equipment (R&TTE)
Direcve
◦2014/35/EU - Low Voltage (LVD) Direcve
◦2014/30/EU - Electromagnec Compability (EMC) Direcve
◦2011/65/EU - EU Restricon of Hazardous Substances (RoHS) Direcve
◦2012/19/EU - Waste Electrical and Electronic Equipment (WEEE) Direcve
•ACME (Australia) Standards
◦AS/NZS 4268:2012+ A1:2013
◦EN 61000-6-1:2007
◦EN 61000-6-3:2007 +A1:2011
◦EN 61000-3-2:2014
◦EN 61000-3-3:2013
19
FABRICATED FOOD
SERVICE
EQUIPMENT
NSF/ANSI 2
SA44549
INFRARED
THERMOMETER
E481655
Industry Canada
Industrie Canada
IC: 21861-THB4002
RCM Cert.
No:
POC16104019
FCC ID:2AE6ATHB4002
20
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT
TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARM-
FUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS
NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH
MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIP-
MENT.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are de-
signed to provide reasonable protecon against harmful interference in a residen-
al installaon. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instrucons, may cause
harmful interference to radio communicaons. However, there is no guarantee
that interference will not occur in a parcular installaon. If this equipment does
cause harmful interference to radio or television recepon, which can be deter-
mined by turning the equipment o and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
FCC Part 15.19 Warning Statement
FCC Compliance
FCC Part 15.21 Warning Statement
FCC Part 15.105 Warning Statement
21
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit dierent from that to which
the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
RF warning statement
The device has been evaluated to meet general RF exposure requirement. The
device can beused in portable exposure condion without restricon.
IC Warning
This device complies with Industry Canada licence-exempt RSS standard(s). Opera-
on is subject to the following two condions: (1) this device may not cause inter-
ference, and (2) this device must accept any interference, including interference
that may cause undesired operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitaon est autorisée aux deux condions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'ulisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est suscepble d'en compromere le fonconnement.
RF warning statement:
The device has been evaluated to meet general RF exposure requirement.
Le disposif de a été évalués à répondre général RF exposion exigence.
22
ZippyYum LLC
275 Centennial Way, #105,
Tusn, CA 92780
Phone: +1 (888) 636-7557
Fax: +1 (866) 434-0883
www.zippyyum.com
www.mangoe.com