THB4002
GoTemp
Food Infrared Thermometer
With Laser Sighting And Thermocouple Jack
User Guide
Measuring Temperature
The Smart Way
Provided by
Table Of Contents
Description ....................................................................
Features ........................................................................
Distance to Spot ...........................................................
Reset .............................................................................
Indicators.......................................................................
Bluetooth & Pairing ......................................................
Specifications ................................................................
Proper Application and Operation ...............................
Power Switch ................................................................
Mounting Bracket .........................................................
Other Operational Considerations ...............................
Maintenance .................................................................
Laser Safety ...................................................................
Warranty .....................................................................
Certifications .................................................................
FCC Compliance Statement ..........................................
IC Warning ...................................................................
11
11
13
13
16
17
18
20
21
Thank you for purchasing GoTemp. We are confident that you will be pleased
with the quality and performance of this product. Please take a few moments to
familiarize yourself with the operation, features, and benefits of this fine product.
CAUTION! – This product is not intended for medical use or use on humans
Description
The zippyYum GoTemp Model THB4002 is smart contactless thermometer
featuring Bluetooth 4.0 Low Energy. GoTemp combines two precision thermometers: accurately calibrated noncontact infrared thermometer and a thermocouple
port for penetration probe. The noncontact mode can be used for quick scans of a
surface temperature, while the probe mode is used to accurately measure internal
temperatures.
GoTemp is a battery operated device and can be recharged via the standard micro
USB connector from any computer or 5V charger. A K-type thermocouple connector is used to connect the insertion probe.
The interface of the device is minimal as it includes an illuminated push button to
provide ability to reset and give feedback about device status and a slide switch to
turn ON and OFF
Features
• Contactless temperature
•
•
•
•
measurement
Laser pointer to indicate
the measured location
Accepts K-type thermocouples
Rechargeable battery
Interchangeable holders
for iPhone 5, 6, 6+, and
universal bracket for use on
all other phone models
Distance to Spot
The field of view (Distance to Spot) is the area or portion of food product that is
being measured thermally. The distance of the infrared thermometer from the
target determines the dimension of this area. The further away from the target, the
larger is the area being measured.
The ideal working range of GoTemp is between 25 mm and 300 mm (1 and 12inches). The laser pointer helps to indicate the measurement spot. To ensure accurate
measurements, the measured spot must fill or exceed the field of view.
Moving closer to the target produces more accurate measures
Reset
To reset GoTemp, press and hold the button for 3 seconds. 5 orange blinks appear
after the reset.
Indicators
GoTemp is equipped with two LEDs to indicate the device’s state. Please note that
Amber color appears if both red and green LEDs are lit simultaneously.
Indicator reflects the device state and warns you if battery is getting low or there is
not enough charge to power device. Green color indicates full battery, orange
means that battery is low and red means battery is empty. Blinking light means the
device is connected to a phone.
You can always check the battery percentage and charging state on the phone’s
display.
Refer to the below table for detailed indicator states
Battery Level
Connected?
Charging?
LED State
Not enough charge
Not enough charge
Not enough charge
Not enough charge
Enough charge
Enough charge
Enough charge
Enough charge
NO
NO
YES
YES
NO
NO
YES
YES
NO
YES
NO
YES
NO
YES
NO
YES
OFF
Orange solid
Red blink
Orange blink
OFF
Green solid
Green blink
Green blink
Bluetooth & Pairing
GoTemp must be paired with smartphone before the first use. Every GoTemp
device has a unique identifier printed on the back, it is known as MAC.
The Mobile App will automatically connect to the
available GoTemp if there is only one GoTemp found
in the range, otherwise, a list will pop up for the user
to select the device to be used. The names of available
GoTemp devices show up as “GOTEMP_XX”, with XX
denoting the last two digits of MAC.
Once the correct GoTemp is chosen, the indicator
starts blinking and a text box appears on mobile app to
enter the PIN. Enter “123456” as pairing PIN.
Specifications
Model: THB4002
Bluetooth Power: 0dBm
Operating Conditions
Parameter
Value
Storage Temperature
Operating Temperature
Humidity
Charging Current
Charging Voltage
-10 - 45°C (14 - 113°F)
10 - 40°C (50 - 104°F)
10 - 90% RH
<100mA
5V
Battery
Parameter
Value
Capacity
Voltage
Lifetime
400 mAh
3.7V
360 hours Standby
16 hours measuring
Laser
Parameter
Value
Peak Wavelength
Optical Power
650nm
<1mW
Probe Temperature
Parameter
Measurement range
Resolution
Accuracy at room
temperature
Repeatability
Response Time
Conditions
Object temperature:
-10- 120°C
Value
-10 - 120°C (14 - 250°F)
0.25°C (0.25°F)
±1°C (2°F)
Within accuracy
1 second
Infrared Temperature
Parameter
Conditions
Value
Measurement range
-10 - 120°C (14 - 250°F)
Resolution
Typical Measurement
Distance
Distance to Spot
Accuracy at room
temperature (25 °C)
Accuracy at room
temperature (25 °C)
Repeatability
Response Time
0.1°C (0.1°F)
25 - 300mm (1-12”)
Object temperature:
0 - 60°C
Object temperature:
< 0 °C or > 60°C
12:1
±0.5°C (2°F)
±1°C (4°F)
Within accuracy
1 second
AVOID STORING THE UNIT IN EXTREME TEMPERATURE CONDITIONS. DO NOT
STORE INFRARED THERMOMETERS BELOW FREEZING TEMPERATURE OR WHERE
THE RADIANT TEMPERATURE MAY EXCEED 48.9°C (120°F)
Proper Application and Operation
The IR thermometer only measures surface temperature,
critical temperatures must be verified with an internal
temperature probe.
Use Probe For
Internal Temperature
To take a spot temperature measurement, aim the sensor
at the desired target and activate the unit. The spot size
measured is indicated in section “Distance to Spot” .
The IR thermometer cannot measure through transparent
surfaces such as glass and plastic. It will measure the
surface temperature of the glass, or plastic instead.
Mind The Measured Spot
Steam, dust, smoke and/or vapors can prevent accurate
measurement by obstructing the unit’s optics. Please
refer to maintenance section for cleaning in case any of
these conditions happened .
Infrared thermometers are not designed for use in high
humidity-condensing environments.
For the most accurate temperature measurements, aim
the infrared thermometer perpendicular to the target. If
possible, the field of view should be an even, horizontal
plane (the flattest surface of a food product being measured).
Remove Transparent Covers
Before Measuring
Keep Unit Clean
Do Not Measure
in High humidity
Keep Device
Perpendicular To
Measured Surface
The IR thermometer is not recommended for use in measuring reflective surfaces such as stainless steel and/or aluminum wrapping. The temperature of a reflective object may
be measured if the surface is coated with a matte material .
The infrared emissivity of a target is a function of the reflective properties of its surface.
GoTemp Emissivity is preset to 0.95 which is optimal for
most Food Products.
Avoid Measuring Shiny
Surfaces
Most Food
Products Do
Not Require
Change of
Emissivity
If the emissivity of the target material is questionable,
determine its value by referring to the emissivity table.
GoTemp emissivity can be changed from 0.1 to 1.0 in 0.01
steps, refer to instruction in the mobile app to modify
emissivity.
GoTemp is designed to work between 10 °C and 40°C (50 104°F). In case a change in temperature happened like
walking in/out of walk-in freezer, the unit must not be used
for at least 15 minutes (preconditioned).
Failure to precondition the unit may result in thermal shock
and/or inaccurate measurements.
GoTemp can display temperatures in Celsius or Fahrenheit,
refer to instruction in the mobile app to change scale.
Precondition
For 15 Minutes
If Ambient
Temperature
Changed
Select Desired
Display Unit
10
Power Switch
Power Switch located on the bottom of GoTemp is
turned OFF to minimize battery drain. Use a small
plastic pin to switch the power button ON before
operation.
Five orange blinks appear at power up. Make sure
the LEDs are working, otherwise, plug charger and
expect flashing orange light.
Power button can be turned off if GoTemp is not
used for long time, which will save battery and
extend its life.
Mounting Brackets
Four mounting brackets are provided for iPhone 5/5s, iPhone 6, iPhone 6+ and
adjustable bracket for use on all other phones.
After turning the switch ON, position the bracket and push it in the guiding grooves
to snap in place. Push the bracket in opposite direction to remove.
11
12
Other Operational Considerations
GoTemp is protected from the following:
•
•
•
EMI (Electro Magnetic Interference) from induction heaters and microwave
ovens
Electrostatic discharge
Should the unit become damaged, check the accuracy of the unit by performing
the verification process recommended in this manual. If the unit is out of calibration, do not rely on it for critical temperature measurements. Contact a zippyYum for information
Maintenance
Field Verification of Accuracy
GoTemp is pre-calibrated. However, their accuracy can be verified in the field by
using the following simple procedure. It is suggested that the accuracy of the instrument be verified on a regular basis.
For food applications, the IR thermometer accuracy should be verified at the relevant critical food temperatures [5°C (41°F); 60/71.1°C (140°/165°F)]. A two-point
verification is recommended.
Materials needed:
1. Aluminum container (beverage can).
2. Matte-black spray paint or matte-black self-adhering paper appliqué. Masking
tape may also be used.
3. Temperature-standard thermometer.
13
Preparation:
Prepare container by painting or applying the matte material to the outer surface.
Verification Procedure:
1. Fill the aluminum container with refrigerated water, insert the temperature
standard thermometer and allow the can and temperature-standard thermometer to come to equilibrium.
2. Take a reading with the IR thermometer. Do not exceed the spot size of the IR
thermometer as indicated on the unit.
3. Compare the temperature reading of the IR unit with the temperature standard thermometer *.
4. Repeat this procedure using hot water.
* If the temperature deviation exceeds accuracy limit, return the unit for repair.
Preparation
Verification
14
Cleaning Instructions
To ensure an accurate temperature reading, the lens of the IR unit should be free
of dirt, dust, moisture, fog, smoke and debris.
To clean the lens, you would need two lint free cotton swabs. Moist a cotton swab
and insert it in the aperture to scrub the deep lens then repeat the same using the
dry cotton swab.
To clean the unit itself, wipe it down with a moist cloth using water based mild
detergent.
Warning! – Do not submerse the unit or wash in dishwasher
15
Laser Safety
Laser pointer in GoTemp is FDA 21 CFR 1040.10, subchapter J compliant. Please
refer to laser specifications in specification section
Warning!
1.
Avoid direct exposure of human eyes to laser light. Eye damage may result.
2.
Never point the laser light at another person.
3.
Keep the laser-equipped unit out of the reach of children.
4.
Avoid indirect exposure via reflective surfaces, such as glass and mirrors.
16
Warranty
ZippyYum LLC warrants that this product, at the time of its sale by ZippyYum, is free
of defects in material and workmanship and component failures under normal and
proper use for a period of one (1) year from date of delivery and applies worldwide.
ZippyYum‘s only obligation is to correct such defects by repair or replacement, at
its option, if within such one year period the product is returned prepaid.
There are no other or implied warranties of any kind, including merchantability
and fitness for a particular purpose. ZippyYum is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to,
or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.
ZippyYum’s liability on any claim for damages arising out of in connection with the
manufacture, sales, installation delivery, or use of the product shall never exceed
the purchase price of the product. The remedies provided herein are the exclusive
remedies under this warranty, whether based on contract, tort or otherwise.
In line with ZippyYum’s policy of continuous development ZippyYum reserves the
right to alter any specifications without notice.
17
Certifications
GoTemp conforms to the following standards:
•
•
•
•
•
UL listed for UL2333 – Standard For Safety - Infrared Thermometers
UL EPH Classified for ANSI/NSF 2 – standard for
FCC CFR47 Part 15 Section 15.247:2014
Industry Canada RSS-247
European Union Directives
◦ 1999/5/EC - Radio & Telecommunications Terminal Equipment (R&TTE)
Directive
◦ 2014/35/EU - Low Voltage (LVD) Directive
◦ 2014/30/EU - Electromagnetic Compatibility (EMC) Directive
◦ 2011/65/EU - EU Restriction of Hazardous Substances (RoHS) Directive
◦ 2012/19/EU - Waste Electrical and Electronic Equipment (WEEE) Directive
•
ACME (Australia) Standards
◦ AS/NZS 4268:2012+ A1:2013
◦ EN 61000-6-1:2007
◦ EN 61000-6-3:2007 +A1:2011
◦ EN 61000-3-2:2014
◦ EN 61000-3-3:2013
18
INFRARED
THERMOMETER
E481655
FABRICATED FOOD
SERVICE
EQUIPMENT
NSF/ANSI 2
SA44549
RCM Cert.
No:
POC16104019
Industry Canada
Industrie Canada
IC: 21861-THB4002
FCC ID:2AE6ATHB4002
19
FCC Compliance
FCC Part 15.19 Warning Statement
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT
TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
FCC Part 15.21 Warning Statement
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS
NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH
MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
FCC Part 15.105 Warning Statement
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
20
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which
the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
RF warning statement
The device has been evaluated to meet general RF exposure requirement. The
device can beused in portable exposure condition without restriction.
IC Warning
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d'en compromettre le fonctionnement.
RF warning statement:
The device has been evaluated to meet general RF exposure requirement.
Le dispositif de a été évalués à répondre général RF exposition exigence.
21
ZippyYum LLC
275 Centennial Way, #105,
Tustin, CA 92780
Phone: +1 (888) 636-7557
Fax: +1 (866) 434-0883
www.zippyyum.com
www.mangoe.com
22

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Has XFA                         : No
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Microsoft® Publisher 2016
Format                          : application/pdf
Creator                         : Ali Olleik
Creator Tool                    : Microsoft® Publisher 2016
Create Date                     : 2017:06:20 12:02:10+03:00
Modify Date                     : 2017:06:21 19:00+08:00
Metadata Date                   : 2017:06:21 19:00+08:00
Document ID                     : uuid:7C2AE172-BE30-4FFC-B3A4-370418593DE7
Instance ID                     : uuid:54fa1e46-40d3-481f-98e7-e64524d8199b
Page Count                      : 22
Author                          : Ali Olleik
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AE6ATHB4002

Navigation menu