dormakaba Canada LPR10M Proximity Reader User Manual LEGIC Installation Manual Part 2

Kaba Ilco Inc. Proximity Reader LEGIC Installation Manual Part 2

LEGIC Installation Manual Part 2

PK2963 03/03  Issue 1 3 of 4NOTES:1.  If the reader is fixed onto a metal surface, use the spacer providedin the kit to ensure that there is minimal interference to the readercaused by its proximity to the metal.   The spacer is optional forconcrete or drywall.1.  If distance between reader and the DCD is greater than the lengthof cable supplied, an extension cable may be required. Themaximum distance is 200 meters of AWG-22 cable. (Alpha 1299series recommended)1.  The LPR-10M interfaces with the access controller through the 9-wire cable. Along with power and ground, the signals carried by thecable are grouped into  two categories: the data interface and theuser interface control. Each category can be programmed toemulate various interface standards, adding flexibility for interfacingwith more access controller types.Interconnecting CableThe interconnecting cable is a 9-wire shielded cable that carries thesignals and power between the LPR-10M and the access control unit.All signals listed in the Table below are TTL-level compatible.ColorSignal nameWiegand InterfaceSignal DirectionSignal nameClock & Data InterfaceSignal DirectionRed+DC-+DC-BlackGND-GND-Violet--/CARD_INOutputGreenDATA0Output/DATAOutputWhiteDATA1OutputCLOCKOutputDrain wireSHIELD-SHIELD-Orange/GREENInput/GREENInputBrown/REDInput/REDInputYellow/BUZZERInput/BUZZERInputBlue/HOLDInput/HOLDInputFigure 2:  Fascia
PK2963 03/03  Issue 1 4 of 4Installation - Connecting to Millenium Door Control Device(DCD)1.  Connect reader unit to the DCD at the J2 and J5 terminals. Referto wire colors in the table above, and refer to Figure 2 on the backof this  sheet.2.  Verify the Reader Select Jumper cap is installed on the DCD’s J1terminal.3.  Tape ends of the four unterminated conductor wires: /CARD IN,Shield, /buzzer and /hold.4.  Apply power to DCD. The red indicator on the reader shouldilluminate.5.  To test the reader, the door MUST HAVE BEEN CREATED in theMillenium software. (Refer to Millenium Operations Manual)987654321 10J2Data 0GroundLEDJ55432154321J3TXR +TXR -Trunk DataCommunicationsBlackGreenRedWhiteBrownJumper J1 is InsertedMaximum Cabling Distance is 500 ft from DCD to Reader.Data 1Figure 3:  Power Connection             www.kabailco.com 1-800-849-8324 CAUTIONChanges or modifications not expressly approved by Kaba Ilcocould void the user’s authority to operate the equipment.

Navigation menu