dormakaba Canada LPR10M Proximity Reader User Manual LEGIC Installation Manual Part 2
Kaba Ilco Inc. Proximity Reader LEGIC Installation Manual Part 2
Contents
- 1. LEGIC Installation Manual Part 2
- 2. LEGIC Installation Manual Part 1
- 3. LEGIC Installation manual Front Cover
LEGIC Installation Manual Part 2
NOTES: 1. If the reader is fixed onto a metal surface, use the spacer provided in the kit to ensure that there is minimal interference to the reader caused by its proximity to the metal. The spacer is optional for concrete or drywall. 1. If distance between reader and the DCD is greater than the length of cable supplied, an extension cable may be required. The maximum distance is 200 meters of AWG-22 cable. (Alpha 1299 series recommended) 1. The LPR-10M interfaces with the access controller through the 9wire cable. Along with power and ground, the signals carried by the cable are grouped into two categories: the data interface and the user interface control. Each category can be programmed to emulate various interface standards, adding flexibility for interfacing with more access controller types. Interconnecting Cable Figure 2: Fascia The interconnecting cable is a 9-wire shielded cable that carries the signals and power between the LPR-10M and the access control unit. All signals listed in the Table below are TTL-level compatible. Color Signal name Wiegand Interface Signal Direction Signal name Clock & Data Interface Signal Direction Red +DC +DC Black GND GND Violet /CARD_IN Output Green DATA0 Output /DATA Output White DATA1 Output CLOCK Output Drain wire SHIELD SHIELD Orange /GREEN Input /GREEN Input Brown /RED Input /RED Input Yellow /BUZZER Input /BUZZER Input Blue /HOLD Input /HOLD Input PK2963 03/03 Issue 1 3 of 4 Installation - Connecting to Millenium Door Control Device (DCD) 1. Connect reader unit to the DCD at the J2 and J5 terminals. Refer to wire colors in the table above, and refer to Figure 2 on the back of this sheet. 2. Verify the Reader Select Jumper cap is installed on the DCD’s J1 terminal. 3. Tape ends of the four unterminated conductor wires: /CARD IN, Shield, /buzzer and /hold. 4. Apply power to DCD. The red indicator on the reader should illuminate. 5. To test the reader, the door MUST HAVE BEEN CREATED in the Millenium software. (Refer to Millenium Operations Manual) J3 Trunk Data Communications TXR + TXR - J5 Jumper J1 is Inserted Maximum Cabling Distance is 500 ft from DCD to Reader. Da en Gr Re Br ow J2 10 hi te Bl ac LE Da ta ta Gr ou nd Figure 3: Power Connection CAUTION www.kabailco.com 1-800-849-8324 Changes or modifications not expressly approved by Kaba Ilco could void the user’s authority to operate the equipment. PK2963 03/03 Issue 1 4 of 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2003:09:30 10:29:12-03:00 Create Date : 2003:09:30 10:28:43-03:00 Creator : Word Producer : Mac OS X 10.2.6 Quartz PDFContext Page Count : 2 Mod Date : 2003:09:30 10:29:12-03:00 Creation Date : 2003:09:30 10:28:43-03:00 Metadata Date : 2003:09:30 10:29:12-03:00EXIF Metadata provided by EXIF.tools