lantronix WIPORTG WIRELESS DEVICE SERVER User Manual USERS GUIDE

lantronix WIRELESS DEVICE SERVER USERS GUIDE

Contents

USERS GUIDE

Download: lantronix WIPORTG WIRELESS DEVICE SERVER User Manual USERS GUIDE
Mirror Download [FCC.gov]lantronix WIPORTG WIRELESS DEVICE SERVER User Manual USERS GUIDE
Document ID672039
Application ID55KK/vSf/Vizp0rQSpmlLg==
Document DescriptionUSERS GUIDE
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize204.96kB (2562026 bits)
Date Submitted2006-06-22 00:00:00
Date Available2006-06-21 00:00:00
Creation Date2006-06-15 11:04:41
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2006-06-15 11:04:41
Document TitleMicrosoft Word - WiBox User Guide 900-351f-WBX-UG_2.doc
Document CreatorPScript5.dll Version 5.2
Document Author: jcandelas

WiBox™ User Guide
6/15/2006
Part Number 900-351
Revision F ??? 2006
Copyright and Trademark
© 2005, 2006 Lantronix. All rights reserved. No part of the contents of this book may
be transmitted or reproduced in any form or by any means without the written
permission of Lantronix. Printed in the United States of America.
WiBox, with its patent-pending technology, is a trademark of Lantronix.
Ethernet is a trademark of XEROX Corporation. UNIX is a registered trademark of
The Open Group. Windows 95, Windows 98, Windows 2000, Windows NT, and
Windows XP are trademarks of Microsoft Corp. Netscape is a trademark of Netscape
Communications Corporation.
Contacts
Lantronix Corporate Headquarters
15353 Barranca Parkway
Irvine, CA 92618, USA
Phone: 949-453-3990
Fax:
949-453-3995
Technical Support
Phone: 800-422-7044 or 949-453-7198
Fax:
949-450-7226
Online: www.lantronix.com/support
Email support@lantronix.com
Sales Offices
For a current list of our domestic and international sales offices, go to the Lantronix
web site at www.lantronix.com/about/contact
WiBox™ User Guide
Contents
List of Tables ___________________________________________________________6
List of Figures __________________________________________________________7
1: Using This Guide
Purpose and Audience ___________________________________________________8
Chapter Summary _______________________________________________________8
Additional Documentation ________________________________________________10
2: Introduction
11
Applications ___________________________________________________________11
Application Examples ___________________________________________________12
Serial Tunneling – Network____________________________________________________12
Ad Hoc Network ____________________________________________________________13
Serial Tunneling – Infrastructure________________________________________________13
Ad Hoc WiBox Connection ____________________________________________________14
WiBox with Ethernet _________________________________________________________14
Protocol Support _______________________________________________________14
Configuration Methods __________________________________________________14
Addresses and Port Numbers _____________________________________________15
Hardware Address __________________________________________________________15
IP Address_________________________________________________________________15
WLAN Settings _____________________________________________________________15
Port Numbers ______________________________________________________________15
Serial Connector Pinouts_________________________________________________16
WBX2100E Network Interface_____________________________________________17
Ethernet Connector Pinouts ___________________________________________________18
LEDs ________________________________________________________________18
Technical Specifications _________________________________________________19
3: Quick Start
20
Required Information ____________________________________________________20
Hardware Address __________________________________________________________20
IP Address_________________________________________________________________20
WLAN Settings _____________________________________________________________20
Installing and Configuring the WiBox________________________________________21
Using Device Installer ___________________________________________________25
Viewing the Current Configuration__________________________________________25
4: Web-Manager Configuration
28
Accessing Web-Manager through a Web Browser _____________________________28
Network Configuration ___________________________________________________29
Automatic IP Address Configuration _____________________________________________29
Static IP Address Configuration ________________________________________________30
Ethernet Configuration _______________________________________________________30
WiBox™ User Guide
Contents
Server Configuration ____________________________________________________31
Hostlist Configuration ___________________________________________________32
Channel 1 and Channel 2 Configuration _____________________________________33
Serial Settings ______________________________________________________________33
Connection Settings - TCP ____________________________________________________36
Connection Settings - UDP ____________________________________________________38
WLAN Configuration ____________________________________________________40
Updating Settings ______________________________________________________42
Apply Defaults _________________________________________________________43
Channel 1 Configuration ______________________________________________________43
Channel 2 Configuration ______________________________________________________43
Expert Settings _____________________________________________________________43
Security Settings ____________________________________________________________44
5: Telnet or Serial Port (Setup Mode) Configuration
45
Accessing Setup Mode __________________________________________________45
Telnet Connection ___________________________________________________________45
Serial Port Connection _______________________________________________________46
Exiting Setup Mode _____________________________________________________46
6: Setup Mode: Server Configuration
47
Server Configuration (Option 0)____________________________________________47
Network Mode ______________________________________________________________47
IP Address ____________________________________________________________47
Set Gateway IP Address _________________________________________________48
Netmask: Number of Bits for Host Part ______________________________________48
Change Telnet Configuration Password _____________________________________48
DHCP Name __________________________________________________________48
7: Setup Mode: Channel Configuration
50
Channel 1 (Option 1) ____________________________________________________50
Baudrate _____________________________________________________________50
I/F (Interface) Mode _____________________________________________________51
Flow_________________________________________________________________51
Port Number __________________________________________________________52
Connect Mode _________________________________________________________52
a) Incoming Connection ______________________________________________________53
b) Response _______________________________________________________________54
c) Active Startup ____________________________________________________________54
d) Datagram Type ___________________________________________________________56
e) Modem Mode ____________________________________________________________57
Send the Escape Sequence (+++) in Modem Mode ____________________________59
Auto Increment Source Port ______________________________________________59
Remote IP Address _____________________________________________________59
Remote Port __________________________________________________________60
DisConnMode _________________________________________________________60
Flush Mode (Buffer Flushing) _____________________________________________61
Pack Control __________________________________________________________61
WiBox™ User Guide
Contents
Packing Interval_____________________________________________________________62
Trailing Characters __________________________________________________________62
Send Characters ____________________________________________________________62
DisConnTime (Inactivity Timeout) __________________________________________62
Send Characters _______________________________________________________63
Telnet Terminal Type____________________________________________________63
Channel (Port) Password ________________________________________________63
WLAN Settings ________________________________________________________63
Enable WLAN ______________________________________________________________64
Topology __________________________________________________________________64
Network Name (SSID) _______________________________________________________64
Ad Hoc Network Creation Channel ______________________________________________64
WEP _____________________________________________________________________64
WPA _____________________________________________________________________65
Data Rate _________________________________________________________________65
Enable Power Management ___________________________________________________66
8: Setup Mode: Advanced Settings
67
Expert Settings (Option 5) ________________________________________________67
TCP Keepalive time in seconds ________________________________________________68
ARP Cache timeout in seconds ________________________________________________68
Enable High Performance_____________________________________________________68
Disable Monitor Mode at bootup ________________________________________________68
HTTP Port Number __________________________________________________________68
SMTP Port Number__________________________________________________________68
MTU Size _________________________________________________________________69
Enable alternate MAC________________________________ Error! Bookmark not defined.
Ethernet Connection Type ____________________________________________________69
Configurable Server Port Number_______________________________________________69
Security Settings _______________________________________________________69
Disable SNMP______________________________________________________________69
SNMP Community Name _____________________________________________________69
Disable Telnet Setup_________________________________________________________70
Disable TFTP Firmware Upgrade _______________________________________________70
Disable Port 77FE (Hex) ______________________________________________________70
Disable Web Server _________________________________________________________70
Disable Web Setup __________________________________________________________70
Disable ECHO Ports _________________________________________________________70
Enable Enhanced Password___________________________________________________70
Enable Encryption ___________________________________________________________71
Factory Defaults ________________________________Error! Bookmark not defined.
Channel 1 Configuration ______________________________________________________72
Channel 2 Configuration ______________________________________________________72
Expert Settings _____________________________________________________________72
Security Settings ____________________________________________________________73
Exit Configuration Mode _________________________________________________73
9: Wireless Bridging
WiBox™ User Guide
74
Contents
Select an option on the menu by entering the number of the option in the Your choice
? field and pressing Enter._________________________Error! Bookmark not defined.
To enter a value for a parameter, type the value and press Enter, or to confirm a current
value, just press Enter. _______________________________ Error! Bookmark not defined.
Configuring the WiBox in Bridging Mode _____________________________________74
Method 1 __________________________________________________________________74
Method 2 __________________________________________________________________74
Method 3 __________________________________________________________________75
10: Monitor Mode
76
Entering Monitor Mode via the Serial Port ____________________________________76
Entering Monitor Mode via the Network Port __________________________________76
Monitor Mode Commands ________________________________________________76
11: Updating Firmware
78
Reloading Firmware ____________________________________________________78
Network Upgrade_______________________________________________________78
Serial Upgrade_________________________________________________________78
Web Pages ___________________________________________________________78
WLAN Country Setting __________________________________________________78
12: Troubleshooting
82
Diagnostic LED States___________________________________________________82
Problems and Error Messages ____________________________________________82
Technical Support ______________________________________________________86
A:
Binary to Hexadecimal Conversions
87
Converting Binary to Hexadecimal _________________________________________87
Conversion Table ___________________________________________________________87
Scientific Calculator _________________________________________________________87
Compliance
MUST BE UPDATED
89
Error! Bookmark not defined.
Compliance Information__________________________________________________89
Regulatory Information __________________________________________________90
USA Federal Communications Commission (FCC) Notice__________________________90
Canada – Industry Canada Notice ______________________________________________90
Europe – R&TTE Directive 99/5/EC, Wireless Notice _______________________________91
Australia & New Zealand – Wireless Notice _______________________________________91
Warranty
93
List of Tables
Table 2-1. WiBox LEDs ___________________________________________________________
Table 2-2. WiBox Technical Specifications ____________________________________________
Table 6-1. BootP/DHCP/AutoIP options ______________________________________________
Table 6-2. Standard IP Network Netmasks ____________________________________________
Table 7-1. Interface Mode Options __________________________________________________
Table 7-2. Common Interface Mode Settings __________________________________________
Table 7-3. Flow Control Options ____________________________________________________
Table 7-4. Reserved Port Numbers__________________________________________________
WiBox™ User Guide
18
19
47
48
51
51
52
52
Contents
Table 7-5. Connect Mode Options __________________________________________________
7-6. Modem Mode Commands _____________________________________________________
Table 7-7. Disconnect Mode Options ________________________________________________
Table 7-8. Flush Mode Options _____________________________________________________
Table 7-9. Pack Control Options ____________________________________________________
Table 10-1. Monitor Mode Commands _______________________________________________
Table 10-2. Command Response Codes _____________________________________________
Table 11-1. Firmware Files ________________________________________________________
53
58
60
61
61
76
77
78
List of Figures
Figure 2-1. Serial Tunneling Infrastructure Network Example______________________________
Figure 2-2. Ad Hoc Network Example ________________________________________________
Figure 2-3. Serial Tunneling Infrastructure Example _____________________________________
Figure 2-4. Direct WiBox to WiBox Connection_________________________________________
Figure 2-5. DB9M DTE Serial Connector _____________________________________________
Figure 2-6. RS-422/485 4-Wire Pinouts ______________________________________________
Figure 2-7. RS-485 2-Wire Pinouts __________________________________________________
Figure 2-8. Network Interface ______________________________________________________
Figure 2-9. RJ45 Ethernet Connector ________________________________________________
Figure 3-1. WiBox Connected for Configuration ________________________________________
Figure 4-1. Web-Manager _________________________________________________________
Figure 4-2. Network Settings NEED NEW SCREEN SHOT _______________________________
Figure 4-3. Server Settings ________________________________________________________
Figure 4-4. Hostlist Settings NEED NEW SCREEN SHOT ________________________________
Figure 4-5. Channel Serial Settings _________________________________________________
Figure 4-6. TCP Connection Settings ________________________________________________
Figure 4-7. UDP Connection Settings ________________________________________________
Figure 4-8. WLAN Settings ________________________________________________________
Figure 5-1. MAC Address NEED NEW_______________________________________________
Figure 5-2. Setup Menu Options ____________________________________________________
Figure 7-1. Serial Port Parameters __________________________________________________
Figure 7-2. Manual Connection Address Example ______________________________________
Figure 8-1. Expert Settings ________________________________________________________
Figure 8-2. Encryption Keys _______________________________________________________
WiBox™ User Guide
12
13
13
14
16
16
17
17
18
21
28
29
31
33
34
36
39
41
46
46
50
55
67
71
1: Using This Guide
Purpose and Audience
This guide provides the information needed to configure, use, and update the WiBox.
It is for network administrators, system integrators, and those responsible for
installing and maintaining the WiBox.
Chapter Summary
The remaining chapters in this guide include:
2: Introduction
Describes the main features of the WiBox and the protocols it
supports.
3: Quick Start
Describes the steps to the physical installation and initial
configuration of the WiBox.
4: Web-Manager
Details using the Web-Manager to set parameters such as port
and server properties.
5: Telnet or Serial Port (Setup
Mode) Configuration
Provides instructions for accessing Setup Mode (command line
interface) using a Telnet connection through the network or a
terminal or terminal emulation program through the serial port.
6: Setup Mode: Server
Configuration
Details the network (server) settings
7: Setup Mode: Channel
Configuration
Details the serial port settings.
8:Setup Mode: Advanced
Settings
Detailsxpert, and security settings and explains how to reset the
unit to default values.
9: Wireless Bridging
Provides information on the WiPort wireless bridging feature.
10:Monitor Mode
Provides instructions for accessing and using the command line
interface for monitoring the network and diagnosing problems.
11: Updating Firmware
Provides instructions for obtaining the latest firmware and updating
the WiBox.
12: Troubleshooting
Describes common problems and error messages and how to
contact Lantronix Technical Support.
A: Binary to Hexadecimal
Conversions
Provides instructions for converting binary numbers to
hexadecimals.
Compliance
Warranty
WiBox™ User Guide
Using This Guide
WiBox™ User Guide
Using This Guide
Additional Documentation
The following guides are available on the product CD and the Lantronix web site
(www.lantronix.com)
Com Port Redirector Online
Help
Provides information on using the Windowsbased utility to create a virtual com port.
Secure Com Port Redirector
User Guide
Provides information on using the Windowsbased utility to create a virtual com port in a
secure environment.
WiBox Quick Start
Provides instructions for getting your WiBox up
and running.
DeviceInstaller Online Help
Provides information on using DeviceInstaller to
assign an IP address and view current
configuration settings.
WiBox™ User Guide
10
2: Introduction
The WiBox™ family of wireless device servers provides serial-to-wireless network
connectivity. They enable virtually any serial device or equipment to be remotely
accessed, controlled, monitored, or shared on an 802.11b/G/G wireless network.
The WiBox provides a fully integrated solution that combines an operating system,
embedded Web server, full TCP/IP protocol stack with an 802.11b/G transceiver
supporting WEP and WPA security, and two high-speed serial ports into a small
compact package. For additional security, the WiBox offers secure data
communications using Rijndael Advanced Encryption Standards (AES).
This device server allows serial devices to connect and communicate over 802.11b/G
wireless networks using IP protocol (TCP for connection-oriented stream applications
and UDP for datagram applications). The WiBox also supports 4-wire RS-422/485
and 2-wire RS-485 protocols for multipoint connections. The WiBox with Ethernet
model provides an Ethernet connection as well.
The WiBox2100 is configurable for wireless bridging (see 9:Wireless Bridging). This
allows a host connected to the WiBox over a wired Ethernet interface to be
accessible over a wireless network.
Name
Model
Part Numbers
WiBox with Ethernet WBX2100E WB21000EG1-01 (115 VAC, 50/60 Hz adapter)
WB21000EG2-01 (100-240 VAC, 50/60 Hz Intl. adapter)
WB2100EGB-01 (WiBox board only)
WB2100EG0-01 (No power supply)
Note: In this User Guide, unless information refers to a specific model, we use the
general term WiBox.
Applications
The WiBox device server connects serial devices such as those listed below to
wireless and Ethernet networks using the IP protocol family.
Security alarms
Access control devices
Fire control panels
Time/attendance clocks and terminals
ATM machines
Data collection devices
RFID readers
Universal Power Supply (UPS) Management units
WiBox™ User Guide
11
Introduction
Telecommunications equipment
Data display devices
Virtually any RS-232, RS-422 or RS-485 asynchronous serial device
Application Examples
The WiBox has two serial ports and an 802.11b/G transceiver. Each serial port is
connected to the serial communication port of a device. The wireless transceiver
connects to another wireless device or to an Access Point (AP). The WBX2100E also
provides an Ethernet connection.
This section includes typical scenarios for using the WiBox.
Serial Tunneling – Network
Figure 2-1. Serial Tunneling Infrastructure Network Example
A PC connected to an AP via an Ethernet connection and a PC with a wireless
connection to the AP LAN access the WiBox as though they are directly connected to
it. The combination of the WiBox, a PC, and Lantronix’s Redirector software allows
the PC to communicate directly to the WiBox’s serial devices, providing wireless
serial tunneling.
WiBox™ User Guide
12
Introduction
Ad Hoc Network
Figure 2-2. Ad Hoc Network Example
In the example above, the AP is not present. The PC makes a direct wireless
connection with the WiBox to manage serial devices. Without an AP, it is a peer-topeer relationship.
Serial Tunneling – Infrastructure
Figure 2-3. Serial Tunneling Infrastructure Example
In the example above, the WiBox communicates with another device server via the
AP. The UDS device server, in this example, is connected via an Ethernet connection
to the AP. In this way, the WiBox and the device server communicate directly and
can transfer information between their serial devices.
WiBox™ User Guide
13
Introduction
Ad Hoc WiBox Connection
Figure 2-4. Direct WiBox to WiBox Connection
In the example above, two WiBoxes have established an Ad Hoc peer-to-peer
relationship. They communicate directly to each other’s serial devices without a PC
or an AP.
WiBox with Ethernet
With this model, you can select either a wireless or an Ethernet connection.
APPLICATION EXAMPLE?
Protocol Support
The WiBox device server uses the TCP/IP protocol stack for network
communications. Other supported protocols include:
ARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, and SNMP for
network communications and management.
TCP, UDP, and Telnet for connections to the serial port.
TFTP for firmware and web page updates.
IP for addressing, routing, and data block handling over the network.
User Datagram Protocol (UDP) for typical datagram applications in which
devices interact with other devices without maintaining a point-to-point
connection.
Configuration Methods
After the physical installation of the WiBox, configuration is required. For the unit to
operate correctly on a network, it must have:
A unique IP address
Appropriate settings for network communications
Methods for logging into the device server and assigning IP addresses (as well as
setting other configurable parameters) include:
Web-Manager: Through a web interface, configure the WiBox and its settings using
the WiBox’s Web-Manager. (See 4: Web-Manager.)
Serial & Telnet Ports: There are two approaches to accessing Serial Mode. Make a
Telnet connection to the network port (9999) or connect a terminal (or a PC running a
terminal emulation program) to the unit’s serial port. (See 5: Telnet or Serial Port
(Setup Mode) Configuration.)
WiBox™ User Guide
14
Introduction
DeviceInstaller: This utility provides a GUI interface for assigning the IP address,
viewing the current configuration, and updating firmware. To use DeviceInstaller for
communication to a WiBox over a wireless network, the WLAN network settings must
be configured first. No such configuration is required for using DeviceInstaller over an
Ethernet network.
Addresses and Port Numbers
Hardware Address
The hardware address is also referred to as the Ethernet address or the MAC
address. The first three bytes of the Ethernet address are fixed and read 00-20-4A,
identifying the unit as a Lantronix product. The fourth, fifth, and sixth bytes are unique
numbers assigned to each unit.
Example: 00-20-4A-14-01-18
IP Address
Every device connected to an IP network must have a unique IP address. This
address references the specific unit. DHCP is enabled by default, and the WiBox
automatically accepts an IP address once the wireless settings are configured for the
wireless network.
WLAN Settings
Before the WiBox can communicate on an 802.11b/G wireless network, the WLAN
settings must match the wireless network. By default, the WiBox is set to Ad Hoc
network mode and its wireless network name (SSID) is LTRX_IBSS.
Port Numbers
Every TCP connection and every UDP datagram is defined by a destination IP
address and a port number. For example, a Telnet application commonly uses port
number 23. A port number is similar to an extension on a phone system.
The unit's serial channel (port) can be associated with a specific TCP/UDP port
number. Port number 9999 is reserved for access to the unit's Setup (configuration)
Mode window. Ports 0-1024 are reserved as well. For more information on reserved
port numbers, refer to Port Number on page 52.
WiBox™ User Guide
15
Introduction
Serial Connector Pinouts
The two DB9M DTE serial ports provide default settings for RS-232C
communications of 9600 baud, 8 bits, no parity, and 1 stop bit (9600, 8, N, 1).
Figure 2-5. DB9M DTE Serial Connector
Alternatively, you can configure the WiBox for RS-422/485 4-wire communications
(Figure 2-6) or for RS-485 2-wire communications (Figure 2-7).
Figure 2-6. RS-422/485 4-Wire Pinouts
WiBox™ User Guide
16
Introduction
Figure 2-7. RS-485 2-Wire Pinouts
WBX2100E Network Interface
The back panel of the WBX2100E contains a 9-30VDC power plug and an RJ45
(10/100) Ethernet port.
Figure 2-8. Network Interface
Power Plug
RJ45 Ethernet Port (WBX2100E only)
WiBox™ User Guide
17
Introduction
Ethernet Connector Pinouts
Figure 2-9. RJ45 Ethernet Connector
LEDs
Table 2-1. WiBox LEDs
LEDs
Meaning
Power LED: Green, steady on
Power is on.
Wireless Link LED: Yellow, blinking
Active wireless connection. Transmitting/receiving.
Wireless Link LED: Yellow, off
Port 1 LED flashes (pauses and
repeats) 4 times
No active connection, searching for network
connection.
Ethernet Link LED: Green,
steady on
Active network connection.
Port 1 LED: Green, steady on
Idle.
Port 1 LED: Green, blinking
Active TCP connection.
Port 2 LED: Yellow, steady on
Idle.
Port 2 LED: Yellow, blinking
Active TCP connection.
WiBox™ User Guide
18
Introduction
Technical Specifications
Table 2-2. WiBox Technical Specifications
CPU, Memory
Lantronix DSTni-EX 186 CPU
256 KB zero wait state SRAM
2048 KB Flash
Serial Interface
Rate is software selectable (300 bps to 921600 bps)
Network Interface
Wireless 802.11b/G
10/100 RJ45 Ethernet (WBX2100E only)
Power Supply
External adapter included
120 VAC (1-01 models) USA
100 – 240 VAC (2-01 models) Universal with regional
connectors
Power Input
9 – 30 VDC (2.5 W maximum)
DC input
Dimensions
Height: 2.3 cm (0.9 in)
Width: 7.3 cm (2.87 in)
Depth: 9.5 cm (3.74 in)
Weight
0.28 kg (0.62 lbs)
Temperature
Operating temperature range: -30°C to 70°C.
Storage temperature range: -40°C to 85°C
VERIFYING WITH DARYL/VAN
Relative Humidity
WiBox™ User Guide
Operating: 10% to 90% non-condensing, 40% to 60%
recommended
Storage: 10% to 90% non-condensing
19
3: Quick Start
This chapter describes installation procedures for the WiBox units.
Required Information
Hardware Address
Take note of the unit’s hardware address (also known as MAC address). It is on the
product label, in the format: 00-20-4a-XX-XX-XX, where the XXs are unique numbers
assigned to the product.
Hardware Address: 00-20-4a-_____-_____-_____
IP Address
The WiBox must have a unique IP address on the network. The systems
administrator generally provides the IP address, subnet mask, and gateway.
IP Address:
_______
_______
_______
_______
Subnet Mask:
_______
_______
_______
_______
Gateway:
_______
_______
_______
_______
WLAN Settings
Before the WiBox can communicate on an 802.11b/G wireless network, the WLAN
settings must match the wireless network. By default, the WiBox is set to Ad Hoc
network mode, and its wireless Network Name (SSID) is LTRX_IBSS.
You can configure either WEP or WPA settings:
Note: WPA Security is only available in infrastructure mode.
WiBox™ User Guide
20
Quick Start
WLAN SSID:
________________ (case-sensitive)
WEP Enabled Y/N?
_______
WEP Key 64 bit or 128 bit?
_______
WEP Key:
____________________________
(Entered in HEX format (0-9 A-F) xx-xx-xx-xx-xx-xx-xx-xx-xx-xx-xx-xx-xx)
or
WPA Enabled Y/N:
____________________________
WPA Key Type hex or passphrase?
WPA Key:
_______
____________________________
Installing and Configuring the WiBox
Complete the following steps to connect and initially configure the WiBox. Initial
configuration is done using the Serial Mode’s Change Setup menu.
Figure 3-1. WiBox Connected for Configuration
1. Connect one end of the supplied DB9F – DB9F null modem serial cable to the
WiBox’s serial port 1.
2. Connect the other end of the DB9 serial cable to a terminal or a PC’s serial COM
port.
3. On the PC, open a terminal emulation application (e.g. HyperTerminal). The
default serial settings are 9600 baud, 8 bits, not parity, 1 stop bit, and no flow
control (9600, 8, N, 1).
4. Enter Setup Mode by simultaneously connecting the power supply and holding
down the x key. Upon connection , the following information displays:
*** Lantronix WiBox Device Server ***
MAC address 00204A8178A4
Software version 05.6b3 (040519)
Press Enter for Setup Mode
5. Press Enter within 5 seconds to display the Change Setup menu.
Two settings are required for the WiBox to communicate on a wireless network:
WiBox™ User Guide
21
Quick Start
The Server (0) settings
The WLAN (4) settings
Current settings display in parentheses.
Note: Due to regulations, the country-specific setting has been removed from the
setup menu and Web-Manager. We provide a separate utility for changing the
Country/Zone setting. The utility is called SetZone and is included in the WiBox
package. It is also available for download from the Lantronix web site.
The syntax is SetZone  []
Leaving the zone blank causes the utility to report the current setting only.
Following are valid zone abbreviations. These settings are consistent with
IEEE802.11b/G zones:
US=United States and Canada
FR=France
JP=Japan
OT=Others, such as Europe (excluding
France), Asia, Africa, and Australia
6. To configure the Server settings, select 0 from the Change Setup menu and edit
the following fields:
a) IP Address: The IP address must be set to a unique value in the network.
Enter each octet and press Enter between each section inputted.
IP Address: IP Address : ( 0) ( 0) ( 0) ( 0) _
b) Set Gateway IP Address: The gateway address should be the IP address of
the router connected to the same LAN segment as the WiBox unit.
Set Gateway IP Address (N) ? Y
Gateway IP addr ( 0) ( 0) ( 0) ( 0)_
c) Netmask: A netmask defines the number of bits taken from the IP address
that are assigned for the host part.
Netmask: Number of Bits for Host Part (0=default)(0)_
d) Change Telnet Configuration Password: Change the Telnet configuration
password to prevent unauthorized access to the Change Setup menu and
Web-Manager.
Change telnet config password (N) ? _
e) Change DHCP Device Name: Change the DHCP name if the network is
DHCP-enabled.
Change DHCP device name (not set) ? (N) N
Enter new DHCP device name :
7. To modify WLAN settings, select 4 WLAN from the Change Setup menu and edit
the following fields:
a) Enable WLAN: Enable the Ethernet or the Wireless interface. When
enabling WLAN, the Ethernet interface is disabled.
Enable WLAN (Y) ? _
b) Topology: Select Infrastructure (ESS) mode or Adhoc (IBSS) mode.
Infrastructure mode communicates with Access Points. Adhoc mode
communicates only with other clients.
WiBox™ User Guide
22
Quick Start
Topology 0=Infrastructure, 1=Adhoc (0) ?
c) Network Name (SSID): Enter the name of the network to which the WiBox
will connect.
Network name (LTRX_IBSS) ? _
d) Ad Hoc Network Creation Channel: When Adhoc mode is selected, and
the WiBox cannot find the specified network, it creates one with that name by
transmitting a beacon on the selected channel.
Channel (11) ?
Only channels allowed in the country for which the WiBox is designated can
be selected. The country is shown in the settings overview.
e) Security: The WiBox features WEP and WPA to secure all wireless
communication. If Adhoc is selected as topology, only WEP is available
Security 0=none, 1=WEP, 2=WPA (0) ? _
f)
WEP:
Authentication 0=open/none, 1=shared (0)
? _
Encryption 0=WEP64, 1=WPE128 (0) ?
Display current key (N) ?
Change key (N) ?
Key type 0=hex, 1=passphrase (0) ?
Enter key:
Authentication selects whether the encryption keys are matched (1 =
shared) with those of the communication partner before passing through
messages or not (2 = open/none).
The Encryption prompt requests the length of the encryption key and the
security strength. WEP64 is 5 bytes or 40 bits (option 0). WEP128 is 13
bytes or 104 bits (option 1).
Select (Y) Yes at the Display current key prompt to show the currently
configured key/passphrase
Change key permits modifying the currently configured key by selecting (Y)
Yes.
The Key type specifies whether the new key is in hexadecimal or
passphrase format.
Enter key prompts for the new encryption key. The passphrase input is not
the same as ASCII input (as used on other products). ASCII is translated
directly into hexadecimal bytes according to the ASCII table. The WiBox
passphrase is hashed using the Neesus Datacom algorithm (for WEP64) or
MD5 (for WEP128).
The passphrase input is safer because it is up to 63 chars long. ASCII input
is a maximum of 5 (WEP64) or 13 (WEP128) characters long and limits the
number of key combinations.
Please refer to the other equipment’s manual to determine the passphrase
input style recommended.
Note: Lantronix recommends using a passphrase of 20 characters or
more for maximum security.
WiBox™ User Guide
23
Quick Start
g) WPA: This firmware version allows only Pre-Shared Keys (PSK) for
authentication and encryption.
Allow WEP group keys (N) ?
Display current key (N) ?
Change key (N) ?
Key type 0=hex, 1=passphrase (1) ?
Enter key: () ?
Selecting (Y) Yes at the Allow WEP group keys prompt enables the
reception of broadcast messages if older WEP equipment shares the same
Access Point.
Select (Y) Yes at the Display current key prompt to show the currently
configured key/passphrase
Change key permits modifying the currently configured key by selecting (Y)
Yes.
The Key type requests whether the new key is in hexadecimal or
passphrase format.
Enter key prompts for the new encryption key. The passphrase input is not
the same as ASCII input (as used on other products). ASCII is translated
directly into hexadecimal bytes according to the ASCII table. The WiBox
passphrase is hashed using the Neesus Datacom algorithm (for WEP64) or
MD5 (for WEP128).
The passphrase input is safer because it is up to 63 chars long. ASCII input
is a maximum of 5 (WEP64) or 13 (WEP128) characters long and limits the
number of key combinations.
Please refer to the other equipment’s manual to determine the passphrase
input style recommended.
Note: Lantronix recommends using a passphrase of 20 characters or
more for maximum security.
h) Data Rate: WiBox permits the control of the transmission rate. Lower data
rates allow for larger distances. It may also be needed to communicate with
older devices. Select 0 - 3 to set a fixed data rate or select 4 - 6 to set a
maximum data rate. This setting allows the radio to lower the data rate in
case of bad link quality.
Data rate, Only : 0=1, 1=2, 2=5.5, 3=11 Mbps or
Up to: 4=2, 5=5.5, 6=11 Mbps (6) ?
i)
Enable Power Management: This allows the software to turn off the radio
when expecting not to receive or transmit soon. This feature reduces the
power consumption by up to 170 mA. Enabling power management
increases the response time, because the radio needs to start up again.
The radio regularly starts to synchronize and check for incoming messages.
Enable power management (N) ? _
8. Upon completing the IP and WLAN settings, select menu option 9 to save and
exit the WiBox Serial Mode.
9. To further configure the WiBox, continue to 4: Web-Manager or 5:Telnet or Serial
Port (Setup Mode) Configuration.
WiBox™ User Guide
24
Quick Start
Using Device Installer
You can use DeviceInstaller, a utility on the product CD, to manually assign the IP
address to the WiBox, view its current configuration settings, and upgrade its
firmware. DeviceInstaller only works with a wired Ethernet connection or if the
wireless settings are already set.
To install the DeviceInstaller:
1. Insert the product CD into your CD-ROM drive.
If the CD does not launch automatically:
a) Click the Start button on the Task Bar and select Run.
b) Enter your CD drive letter, colon, backslash, deviceinstaller.exe (e.g.,
E:\deviceinstaller.exe).
2. Click the DeviceInstaller button. The installation wizard window displays.
3. Respond to the installation wizard prompts. (When prompted to select an
installation type, select Typical.)
4. Once DeviceInstaller has been installed, follow the instructions in
DeviceInstaller’s online Help to assign the IP address and view the current
configuration.
5. To further configure the WiBox, continue onto 4: Web-Manager or or 5:Telnet or
Serial Port (Setup Mode) Configuration.
Viewing the Current Configuration
ARE THESE STILL THE SAME?
After locating the WiBox as described in DeviceInstaller Help, you can view its
current configuration.
To view the WiBox’s configuration settings:
1. In the right window, click the Device Details tab. The current WiBox configuration
displays:
Name
A name to identify the WiBox. Double-click the field, type the
value, and press Enter to complete. This name is not visible
on other PCs or laptops using DeviceInstaller.
Group
A group to categorize the WiBox. Double-click the field, type
the value, and press Enter to complete. This group name is
not visible on other PCs or laptops using DeviceInstaller.
Comments
Comments about the WiBox. Double-click the field, type the
value, and press Enter to complete. This description or
comment is not visible on other PCs or laptops using
DeviceInstaller.
Device Family
Displays the WiBox’s device family type as Wireless.
Type
Displays the device type as WiBox.
ID
Displays the WiBox’s ID embedded within the box.
Hardware Address
Displays the WiBox’s hardware (or MAC) address.
Firmware Version
Displays the firmware currently installed on the WiBox.
WiBox™ User Guide
25
Quick Start
Extended Firmware
Version
Displays the firmware currently installed on the WiBox.
Online Status
Displays the WiBox’s status as online, offline, unreachable
(the WiBox is on a different subnet), or busy (the WiBox is
currently performing a task).
Telnet Enabled
Displays True if the unit can be accessed using Telnet.
Telnet Port
Displays the unit's port for Telnet sessions.
Web Enabled
Displays True if the unit can be accessed using WebManager.
WebPort
Displays the WiBox’s port for Web-Manager configuration.
Maximum Baud Rate
Supported
Displays the WiBox’s maximum baud rate. Note: The WiBox
may not currently be running at this rate.
Firmware Upgradeable
Displays True, indicating the WiBox’s firmware is upgradeable
as newer version become available.
IP Address
Displays the WiBox’s current IP address. To change the IP
address, click the Assign IP Address button.
Number of COB
partitions supported
Displays the number of COB partitions supported (between 19
and 59).
DynamicIP
Indicates whether the current IP address was set using static
or DHCP.
Subnet Mask
Displays the WiBox’s current subnet mask. To change the
subnet mask, click the Assign IP Address button.
Gateway
Displays the WiBox’s current gateway. To change the
gateway, click the Assign IP Address button.
Number of Ports
Displays the number of ports on the WiBox.
TCP Keepalive valid
range
Displays 45, the WiBox’s TCP keepalive range.
Supports Configurable
Pins
False
Supports Email Triggers
False
Supports AES Data
Stream
WiBox unit supports AES encryption.
Supports 485
WiBox supports the RS-485 protocol.
Supports 920K Baudrate
WiBox supports baud rates up to 920K.
Supports Wired Ethernet
WBX2100E supports wired Ethernet.
WiBox™ User Guide
26
Quick Start
Supports HTTP Setup
WiBox supports HTTP setup.
Supports 230K Baudrate
WiBox supports a baud rate of 230K.
Supports GPIO
Communication
False
WiBox™ User Guide
27
4: Web-Manager Configuration
This chapter describes how to configure the WiBox using Web-Manager, Lantronix’s
browser-based configuration tool. The unit’s configuration is stored in nonvolatile
memory and is retained without power. The unit performs a reset after the
configuration is changed and stored.
Accessing Web-Manager through a Web Browser
1. Open a standard web browser (Netscape Navigator 6.x and above, or Internet
Explorer 5.5. and later).
2. In the address bar, enter the WiBox IP address or host DHCP name as listed
below:
a) http://xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address assigned to
the WiBox unit).
b) http://my_WiBox (where “my_WiBox” is the name assigned to the WiBox unit
if DHCP is enabled).
c) Cxxxxxx (where xxxxxxx is the last 6 digits of the unit’s MAC address on
DHCP-enabled networks).
3. Press Enter. The Web-Manager for WiBox opens in a browser window.
Figure 4-1. Web-Manager
WiBox™ User Guide
28
Web-Manager Configuration
The main menu is on the left panel of the Web-Manager window.
Network Configuration
The unit’s network values display upon selecting Network from the main menu. The
following sections describe the configurable parameters within the Network
configuration menu.
Note: If the IP address is assigned via DHCP, its DHCP settings are not
displayed.
Figure 4-2. Network Settings NEED NEW SCREEN SHOT
Automatic IP Address Configuration
To automatically assign an IP address and its network configuration:
1. Click Network from the main menu.
2. Select Obtain IP address automatically.
3. Enter the following (as necessary):
BOOTP
Select Enable to permit the Bootstrap Protocol (BOOTP). The
BOOTP server automatically assigns the IP address from a
pool of addresses.
DHCP
Select Enable to permit Dynamic Host Configuration Protocol
(DHCP). DHCP automatically assigns a leased IP address to
the WiBox unit.
Auto-IP
The WiBox generates an IP in the 169.254.x.x address range
with a Class B subnet Select the Disable checkbox to disable
WiBox™ User Guide
29
Web-Manager Configuration
this feature.
DHCP Host Name
Enter the name of the host on the network providing the IP
address.
Note: Consult the System or Network Administrator before adjusting these
settings. Disabling all three methods is not advised as the only available IP
assignment method will then be ARP or serial port.
4. Click the OK button when finished.
5. On the main menu, click Apply Settings.
Static IP Address Configuration
To manually assign an IP address and its network configuration:
1. Click Network from the main menu.
2. Select Use the following IP configuration.
3. Enter the following (as necessary):
IP Address
If DHCP is not used to assign IP addresses, enter it manually.
The IP address must be set to a unique value in the network.
Subnet Mask
A subnet mask defines the number of bits taken from the IP
address that are assigned for the host part.
Default Gateway
The gateway address, or router, allows communication to
other LAN segments. The gateway address should be the IP
address of the router connected to the same LAN segment as
the WiBox. The gateway address must be within the local
network.
4. Click the OK button when finished.
5. On the main menu, click Apply Settings.
Ethernet Configuration
TOOK FROM COBOS MASTER. DOES THIS BELONG HERE?
You must specify the speed and direction of data transmission.
To specify how data will be transmitted:
1. On the main menu, click Network.
2. Enter the following (as necessary):
Auto Negotiate
With this option, the Ehernet port auto-negotiates the speed
and duplex with the hardware endpoint to which it is
connected. This is the default setting.
If this option is not selected, complete the fields that become
available:
Speed: The speed of data transmission. The default setting is
100 Mbps.
Duplex: The direction of data transmission. The default
setting is Full.
3. When you are finished, click the OK button.
WiBox™ User Guide
30
Web-Manager Configuration
4. On the main menu, click Apply Settings.
Server Configuration
The unit’s server values display upon selecting Server from the main menu. The
following sections describe the configurable parameters within the Server
configuration menu.
Figure 4-3. Server Settings
To configure the WiBox’s device server settings:
1. Click Server from the main menu.
2. Configure or modify the following fields:
Server Configuration
Telnet Password
Enter the password required for Telnet access.
Retype Password
Re-enter the password required for Telnet access.
Advanced
ARP Cache Timeout
When the unit communicates with another device on the
network, it adds an entry into its ARP table. ARP Cache
timeout defines the number of seconds (1-600) before it
refreshes this table.
TCP Keepalive
TCP Keepalive time defines how many seconds the unit waits
during an inactive connection before checking its status If the
WiBox™ User Guide
31
Web-Manager Configuration
unit does not receive a response, it drops that connection.
Enter a value between 1 and 65 seconds. 0 disables
keepalive. The default setting is 45.
Monitor Mode @ Bootup
Select Disable to disable the entry into the monitor mode via
the yyy or xx1 key sequence at startup. This command
prevents the unit from entering monitor mode by interpreting
the stream of characters that are received during the device
server's initialization at startup.
CPU Performance Mode
The WiBox provides a high-performance mode that supports
the baud rates 460 Kbps and 921 Kbps. When running the
serial port at 460 Kbps or 921Kbps, the CPU must be placed
in the high performance mode to keep the serial port within
this baud rate specification. The maximum serial speed when
not in high performance mode is 230 Kbps. The default is
Low.
FROM COBOS MASTER
Select the WiBox’s performance mode. Higher performance
settings require more energy. Regular is 48 Mhz; High is 88
Mhz. The default setting is Regular.
HTTP Server Port
This option allows the configuration of the web server port
number. The valid range is 1-65535. The default HTTP server
port number is 80.
MTU Size? DOES WIBOX
HAVE THIS?
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Hostlist Configuration
The hostlist operates in a sequential order when attempting to connect to the first
available host. The WiBox scrolls through the hostlist until it connects to a device
listed in the hostlist table. After a successful connection, the unit stops trying to
connect to any others. If this connection fails, the unit continues to scroll through the
table until the next successful connection.
The hostlist supports a minimum of 1 and a maximum of 12 entries. Each entry
contains an IP address and a port number.
Note: The hostlist is disabled for Manual and Modem Mode. The unit will not
accept a data connection from a remote device when the hostlist option is
enabled.
To configure the WiBox’s hostlist:
1. From the main menu, click the Hostlist tab.
WiBox™ User Guide
32
Web-Manager Configuration
Figure 4-4. Hostlist Settings NEED NEW SCREEN SHOT
2. Enter or modify the following fields from the Hostlist Settings window:
Retry Settings
Retry Counter
Enter the value for the number of times the WiBox should
attempt to retry connecting to the hostlist. The default setting
is 3.
Retry Timeout
Enter the duration (in seconds) the WiBox should abandon
attempting a connection to the hostlist. The default setting is
250.
Host Information
Host Address
Enter or modify the host’s IP address.
Port
Enter the target port number.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Channel 1 and Channel 2 Configuration
Channel 1 and Channel 2 configurations define how the serial ports respond to
network and serial communication.
Serial Settings
To configure a channel’s serial settings:
WiBox™ User Guide
33
Web-Manager Configuration
1. From the main menu, click Serial Settings for either Channel 1 or Channel 2 to
display the Serial Settings page for the selected channel.
Figure 4-5. Channel Serial Settings
2. In the available fields, enter the following information:
Channel
Disable Serial Port
Available on Channel 2 settings only. When selected, disables
communication through the serial port.
Port Settings
Protocol
Select the protocol type from the pull-down menu for the
selected channel. Available options are RS232, RS422/485
(for 4-wire mode), and RS485 (for 2-wire mode). Applies to
Channel 2 only.
Flow Control
Flow control manages data flow between devices in a network
to ensure it is processed efficiently. Too much data arriving
before a device is prepared to manage it causes lost or
retransmitted data. The default is None.
Baud Rate
The unit and attached serial device, such as a modem, must
agree on a speed or baud rate to use for the serial connection.
Valid baud rates are 300, 600, 1200, 2400, 4800, 9600
(default), 19200, 38400, 57600, 115200, 230400, 460800, or
921600. For baud rates 460 and 921 Kbps, the CPU
Performance Mode must be set to High. NOT IN COBOS
MASTER.
Data Bits
Indicates the number of character bits. The default setting is 8.
WiBox™ User Guide
34
Web-Manager Configuration
Parity
Checks for the parity bit. The default setting is None.
Stop Bits
The stop bit follows the data and parity bits in serial
communication. It indicates the end of transmission. The
default setting is 1.
Pack Control
Enable Packing
Select the checkbox to enable packing on the WiBox.
Two firmware-selectable packing algorithms define how and
when packets are sent to the network.
The standard algorithm is optimized for applications in which
the unit is used in a local environment, allowing for very small
delays for single characters, while keeping the packet count
low.
The alternate packing algorithm minimizes the packet count
on the network and is especially useful in applications in a
routed Wide Area Network (WAN). Adjusting parameters in
this mode can economize the network data stream.
Disabled by default.
Idle Gap Time
Select the maximum time for inactivity. The default time is 12
milliseconds.
Match 2 Byte Sequence
Use to indicate the end of a series of data to be sent as one
group. The sequence must occur sequentially to indicate to
the WiBox end of the data collection. The default is No.
Match Bytes
Use to indicate the end of a series of data to be sent as one
group. Set this value to 00 if specific functions are not needed.
Send Frame Only
After the detection of the byte sequence, indicates whether to
send the data frame or the entire buffer. Select Yes to send
only the data frame. The default is No.
Send Trailing Bytes
Select the number of bytes to send after the end-of-sequence
characters. The default None.
Flush Input Buffer (Serial to Network)
With Active Connect
Select Yes to clear the input buffer with a connection that is
initiated from the device to the network. The default is No.
With Passive Connect
Select Yes to clear the input buffer with a connection initiated
from the network to the device. The default is No.
At Time of Disconnect
Select Yes to clear the input buffer when the network
connection to or from the device is disconnected. The default
is No.
Flush Output Buffer (Network to Serial)
With Active Connect
WiBox™ User Guide
Select Yes to clear the output buffer with a connection that is
initiated from the device to the network. The default is No.
35
Web-Manager Configuration
With Passive Connect
Select Yes to clear the output buffer with a connection initiated
from the network to the device. The default is No.
At Time of Disconnect
Select Yes to clear the output buffer when the network
connection to or from the device is disconnected. The default
is No.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Connection Settings - TCP
To configure a channel’s TCP settings:
1. From the main menu, click Connection for either Channel 1 or Channel 2 to
display the Connection Settings page for the selected channel.
2. In the available fields, enter the following information:
Connect Protocol
Protocol
Select TCP from the pull-down menu.
Figure 4-6. TCP Connection Settings
Connect Mode: Passive Connection
Accept Incoming
Select Yes to accept incoming connections.
Password Required
Determines whether a password is required for an incoming
passive connection. This field is not available when a
password is set for Telnet mode. The default setting is No.
WiBox™ User Guide
36
Web-Manager Configuration
Password
If Password Required was set to Yes, enter the password for
passive connections.
Connect Mode: Active Connection
Active Connect
Select None (default) to disable Active Connect. Otherwise,
indicate the connection type from the drop-down list:
With Any Character: Attempts to connect when any
character is received from the serial port.
With Active Mdm Ctrl In: Accepts external connection
requests only when the modem_control_in input is asserted.
With Start Character: Attempts to connect when it receives a
specific start character from the serial port. The default start
character is carriage return.
Manual Connection: Attempts to connect when directed by a
command string received from the serial port.
Auto Start: Automatically connects to the remote IP address
and port after booting up.
Start Character
If Active Connect is set to With Start Character, enter the
start character in this field. The default setting is 0D.
Modem Mode
Indicates the on-screen response type when in Modem Mode
(if Modem Mode is enabled). The default setting is None.
Endpoint Configuration
Local Port
Enter the local port number.
Auto increment local
port number
Select to auto-increment the local port number for new
outgoing connections. The range of auto-incremented port
numbers is 50,000 to 59,999 and loops back to the beginning
when the maximum range is reached. Disabled by default.
Remote Port
Enter the remote port number.
Remote Host
Enter the IP address of the remote device.
Common Options
Telnet Mode
This field is available for configuration only when Active
Connection is not set to None. Select Enable to permit
Telnet communication to the WiBox unit.
Terminal Name
This field is available for configuration only when Telnet Mode
is Enable.
Use the terminal name for the Telnet terminal type. Enter only
one name. When this option is enabled, the unit also reacts to
the EOR (End Of Record) and binary options, which can be
used for applications such as terminal emulation to IBM hosts.
Connect Response
A single character is transmitted to the serial port when there
WiBox™ User Guide
37
Web-Manager Configuration
is a change in connection state. The default setting is None.
Use Hostlist
The hostlist operates in a sequential order when attempting to
connect to the first available host. If this option is set to True,
the device server scrolls through the hostlist until it connects
to a device listed in the hostlist table. Once it connects, the
unit stops trying to connect to any others. If this connection
fails, the unit continues to scroll through the table until it is
able to connect to another IP in the hostlist.
The hostlist is disabled for Manual Mode and for Modem
Mode. The unit will not accept a data connection from a
remote device when the hostlist option is enabled..
LED
Select Blink for the status LEDs to blink upon connection or
None for no LED output. The default setting is Blink.
Disconnect Mode
On Mdm_Ctrl_In Drop
Set to Yes for the network connection to or from the serial port
to drop when modem_control_in transitions from a high state
to a low state. The default setting is No.
Hard Disconnect
When set to Yes, the TCP connection closes even if the
remote site does not acknowledge the disconnect request.
With EOT
Select Yes to drop the connection when Ctrl+D or Hex 04 is
detected. Both Telnet mode and Disconnect with EOT must
be enabled for Disconnect with EOT to function properly.
Ctrl+D is only detected going from the serial port to the
network. The default setting is No.
Inactivity Timeout
Use this parameter to set an inactivity timeout. The unit drops
the connection if there is no activity on the serial line before
the set time expires. Enter time in the format mm:ss, where m
is the number of minutes and s is the number of seconds. To
disable the inactivity timeout, enter 00:00.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Connection Settings - UDP
To configure a channel’s UDP settings:
1. From the main menu, click Connection for either Channel 1 or Channel 2 to
display the Connection Settings page for the selected channel.
Connect Protocol
Protocol
WiBox™ User Guide
Select UDP from the pull-down menu.
38
Web-Manager Configuration
Figure 4-7. UDP Connection Settings
2. In the available fields, enter the following information:
Datagram Mode
Datagram Type
Configures remote IP or network broadcast address and the
remote port. Enter 01 for directed or broadcast UDP. The
default setting is 00.
Accept Incoming
Select Yes to accept incoming UDP datagrams.
Endpoint Configuration
Local Port
Enter the local port number.
Remote Port
Enter the port number of the remote device.
Remote Host
Enter the IP address of the remote device.
Device Address Table
This table is enabled when Datagram Type is set to FD. Enter
values between 1-255 to identify units on the local network of
device servers.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
WiBox™ User Guide
39
Web-Manager Configuration
WLAN Configuration
Without adequate protection, a wireless LAN is susceptible to access by
unauthorized users.
The WiBox WLAN Settings menu permits the following actions:
Configuration of the wireless network profile available for activation.
Configuration of the wireless network security settings.
Configuration of advanced settings such as radio power management.
Note: Due to regulations, the country-specific setting has been removed from the
setup menu and Web-Manager. We do, however, provide a separate utility for
changing the Country/Zone setting. The utility is called SetZone and is included in
the WiBox package. It is also available for download from the Lantronix web site.
The syntax is SetZone  []
Leaving the zone blank causes the utility to report the current setting only. Following
are valid zone abbreviations. These settings are consistent with IEEE802.11b/G
zones:
US=United States and Canada
FR=France
JP=Japan
OT=Others, such as Europe (excluding
France), Asia, Africa, and Australia
To configure the WiBox’s WLAN settings:
1. Select WLAN from the main menu to open the WLAN Settings window.
WiBox™ User Guide
40
Web-Manager Configuration
Figure 4-8. WLAN Settings
2. Enter or modify the following fields:
Network Interface
Use the pull-down menu to select a WLAN interface or an
Ethernet interface.
Wireless Network Configuration
Network Name
Enter the name of the wireless network (SSID). The WiBox
connects to this wireless network.
Network Type
Select Infrastructure or Ad Hoc.
Channel
Configurable only when Network Type is Ad Hoc. Select
from the pull-down menu the radio channel for the Ad Hoc
network. The default value is 11.
Wireless Network Security
Security
As a security measure, enable WEP or WPA on the WiBox.
By default, wireless security is disabled on the WiBox.
WEP Options
Authentication
Select an authentication scheme (Open/None or Shared)
from the drop down menu.
Encryption
Select the encryption type (64 bits or 128 bits for WEP) from
the pull-down menu. 64 bits is the default encryption for WEP.
WiBox™ User Guide
41
Web-Manager Configuration
Key Type
Select the key type (Hex or Passphrase).
Key
Enter the Encryption Key in hexadecimal value if Hex is
selected as the key type. Enter the key as a string if
Passphrase is selected as the key type. Passphrase input is
not the same as ASCII input .
A passphrase of more than 20 characters is recommended.
Spaces and punctuation characters are permitted.
WPA Options
Authentication
Select Pre-Shared Keys from the drop down menu.
Encryption
Select the encryption type from the pull-down menu. TKIP is
the default encryption for WPA.
Key Type
Select the key type (Hex or Passphrase).
Key
Enter the Encryption Key in hexadecimal value if Hex is
selected as the key type. Enter the key as a string if
Passphrase is selected as the key type. Passphrase input is
not the same as ASCII input.
A passphrase of more than 20 characters is recommended.
Spaces and punctuation characters are permitted.
Advanced Settings
Data Rate
WiBox permits the control of the transmission data rate. Click
the Auto check box to allow the WiBox to automatically set
the data rate (or leave unchecked to manually set the
transmission rate). The default rate is 11 Mbps.
If the Auto check box is selected, choose the maximum data
rate from the drop down menu.
If the Auto check box is not selected, select the fixed data
rate (in Mbps) from the drop down menu.
IS THE FOLLOWING TRUE FOR WIBOX?
Note: For WiPort version WP2001000G-02 (WiPort-G), the
maximum data rate cannot be selected when the WiPort
automatically sets the data rate. WiPort-G supports the
following additional rates: 18 Mbps, 24 Mbps, 36 Mbps, and
54 Mbps.
Radio Power
Management
Power management reduces the overall power consumption
of the WiBox unit. Selecting Enable increases the response
time.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Updating Settings
1. If you have not already done so, click the Apply Settings button from the main
menu to save and apply the configuration changes.
WiBox™ User Guide
42
Web-Manager Configuration
Apply Defaults
Click the Apply Defaults button to reset the unit’s Channel 1 configuration, Channel
2 configuration, Security, and Expert settings to the factory default settings. The
server configuration settings for IP address, gateway IP address, netmask, and
WLAN remain unchanged. The specific settings that this option changes are listed
below:
CHECK THESE
Channel 1 Configuration
Baudrate
9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C)
Port No
10001
Connect Mode
C0 (always accept incoming connection; no active
connection startup)
Hostlist Retry Counter
Hostlist Retry Timeout
250 (msec)
Send Character
0x0D (CR)
All other parameters
Channel 2 Configuration
Baudrate
9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C)
Port No
10002
Connect Mode
C0 (always accept incoming connection; no active
connection startup)
Hostlist Retry Counter
Hostlist Retry Timeout
250 (msec)
Send Character
0x0D (CR)
All other parameters
WLAN Settings
Enable WLAN
(Y) Yes
Topology
Infrastructure
Network Name
LTRX_IBSS
Channel
11
Security
0 (none)
WiBox™ User Guide
43
Web-Manager Configuration
TX Data Rate
0 (fixed)
TX Data Rate
11 Mbps
Enable Power Management
N (No)
Expert Settings
TCP keepalive
45 (seconds)
ARP cache timeout
600 (seconds)
CPU performance
Disabled
Disable Monitor Mode
(N) No
HTTP port number
0 (resulting in an operational value of 80)
WHAT ABOUT:
MTU Size
1400
Enable Alternate MAC
N (No) ( for OEM use only)
Ethernet Connection Type
0 (auto negotiate)
Security Settings
Disable SNMP
(N) No
SNMP Community Name
Public
Disable Telnet Setup
(N) No
Disable TFTP Firmware Update
(N) No
Disable Port 77FEh
(N) No
Disable Web Server
(N) No
Disable Web Setup
(N) No
Disable ECHO ports
(N) No
Enable Encryption
(N) No
Enable Enhanced password
(N) No
WiBox™ User Guide
44
5: Telnet or Serial Port (Setup Mode)
Configuration
You must configure the unit so that it can communicate on a network with your serial
device. As an alternative to using a web browser, as described in the previous
chapter, you can use the following procedures remotely or locally:
Use a Telnet connection to configure the unit over the network.
Use a terminal or terminal emulation program to access the serial port
locally.
The series of prompts at which you enter configuration settings is called Setup
Mode.
Note: Detailed information about other setup methods is available from your
Lantronix Sales Associate.
The unit’s configuration is stored in nonvolatile memory and is retained without
power. You can change the configuration at any time. The unit performs a reset after
the configuration has been changed and stored.
This chapter tells you how to access Setup Mode and the general procedure for
using it. To complete the configuration, continue with 6:Setup Mode: Server
Configuration, 7:Setup Mode: Channel Configuration, and 8:Setup Mode: Advanced
Settings.
Note: The menus in the configuration chapters show a typical device. Your
device may have different configuration options.
Accessing Setup Mode
Telnet Connection
To configure the unit over the network, establish a Telnet connection to port 9999.
Note: You can also use DeviceInstaller to access Telnet. Select the device
from the main window list, and click the Telnet Configuration tab. Skip
steps 1 and 2.
To establish a Telnet connection:
1. From the Windows Start menu, click Run and type the following command,
where x.x.x.x is the IP address, and 9999 is the unit’s fixed network configuration
port number:
Windows: telnet x.x.x.x 9999
UNIX: telnet x.x.x.x:9999
2. Click OK. The following information displays.
WiBox™ User Guide
45
Telnet or Serial Port (Setup Mode) Configuration
Figure 5-1. MAC Address
3. To enter Setup Mode, press Enter within 5 seconds. The current configuration
settings display, followed by the Change Setup menu.
Figure 5-2. Setup Menu Options***
Change Setup:
0 Server
1 Channel 1
2 Channel 2
4 WLAN
5 Expert
6 Security
7 Factory defaults
8 Exit without save
9 Save and exit
Your choice ?
4. Select an option on the menu by entering the number of the option in the Your
choice ? field and pressing Enter.
5. To enter a value for a parameter, type the value and press Enter, or to confirm a
current value, just press Enter.
6. When you are finished, save the new configuration (option 9). The unit reboots.
Serial Port Connection
To configure the unit through a serial connection:
1. Connect a console terminal or PC running a terminal emulation program to your
unit's serial port. The default serial port settings are 9600 baud, 8 bits, no
parity, 1-stop bit, no-flow control.
2. Reset the WiBox unit by cycling the unit's power (turning the power off and back
on). Immediately upon resetting the device, enter three lowercase x characters
(xxx).
Note: The easiest way to enter Setup Mode is to hold down the x key at
the terminal (or emulation) while resetting the unit. You must do this
within three seconds of resetting the WiBox.
At this point, the screen display is the same as when you use a Telnet connection. To
continue, go to step 3 in Telnet Connection, above.
Exiting Setup Mode
To exit setup mode:
You have two options:
To save all changes and reboot the device, select option 9 Save and exit
from the Change Setup menu. All values are stored in nonvolatile memory.
To exit the configuration mode without saving any changes or rebooting.
select option 8 Exit without save from the Change Setup menu.
WiBox™ User Guide
46
6: Setup Mode: Server Configuration
This chapter explains how to configure the network settings.
Note: Current values display in parentheses.
Server Configuration (Option 0)
The unit’s basic network parameters display when you select Server configuration
(option 0). The IP Address, Set Gateway IP Address, and Netmask fields display
the current values.
IP Address : (000) .(000) .(000) .(000)
Set Gateway IP Address (N)
Netmask: Number of Bits for Host Part (0=default)
Change telnet config password (N)
(0)
Network Mode
Select the network mode for the WiBox. Options available are Wired Only, Wireless
Only, and Bridging. For more information on bridging, see 9:Wireless Bridging.
Network Mode <0=Wired Only 1=Wireless Only
2=Bridging >:
IP Address
If DHCP is not used to assign IP addresses, enter the IP address manually. The IP
address must be set to a unique value in the network. Enter each octet and press
Enter between each section. The current value displays in parentheses.
IP Address : (000) (000) (000) (000) _
If DHCP is used, the third octet of the IP address sets the BootP/DHCP/AutoIP
options. The following table shows the bits you can manually configure to force the
Product Name to disable AutoIP, DHCP, or BootP. To disable an option, set the
appropriate bit.
Table 6-1. BootP/DHCP/AutoIP options
Options
Bit
AutoIP
DHCP
BootP
For example, if the third octet is 0.0.5.0, the AutoIP and BootP options are disabled;
only DHCP is enabled. (The value 5 results from adding the binary equivalents of 0
and 2.) This is the most common setting when using DHCP.
WiBox™ User Guide
47
Configuration via Serial Mode or Telnet Port
Set Gateway IP Address
The gateway address, or router, allows communication to other LAN segments. The
gateway address should be the IP address of the router connected to the same LAN
segment as the unit. The gateway address must be within the local network. The
default setting is N (No), meaning the gateway address has not been set. To set the
gateway address, type Y and enter the address.
Set Gateway IP Address (N) ? Y
Gateway IP addr (000) (000) (000) (000)_
Netmask: Number of Bits for Host Part
A netmask defines the number of bits taken from the IP address that are assigned for
the host part.
Netmask: Number of Bits for Host Part (0=default) (0) _
Note: Class A: 24 bits; Class B: 16 bits; Class C: 8 bits
The unit prompts for the number of host bits to be entered, then calculates the
netmask, which appears in standard decimal-dot notation (for example,
255.255.255.0) when the saved parameters display. The default setting is 0.
Table 6-2. Standard IP Network Netmasks
Network Class
Host Bits
Netmask
24
255.0.0.0
16
255.255.0.0
255.255.255.0
Change Telnet Configuration Password
Setting the Telnet configuration password prevents unauthorized access to the setup
menu through a Telnet connection to port 9999 or through web pages. The password
must have 4 characters. The default setting is N (No).
Change telnet config password (N) ? _
An enhanced password setting (for Telnet access only) of 16 characters is available
under Security Settings on page 69.
Note: You do not need a password to access the Setup Mode window by a
serial connection.
DHCP Name
If a DHCP server has automatically assigned the IP address and network settings,
you can discover the unit by using the DeviceInstaller network search feature or
Monitor Mode (see 10: Monitor Mode).
WiBox™ User Guide
48
Configuration via Serial Mode or Telnet Port
Note: When you enter Monitor Mode from the serial port with network
connection enabled and issue the NC (Network Communication) command,
you see the unit’s IP configuration.
There are three methods for assigning DHCP names to the unit.
Default DHCP Name: If you do not change the DHCP name, and you are
using an IP of 0.0.0.0, then the DHCP name defaults to CXXXXXX (XXXXXX
is the last 6 digits of the MAC (hardware) address shown on the label on the
bottom/side of the unit). For example, if the MAC address is 00-20-4A-12-3456, then the default DHCP name is C123456.
Custom DHCP Name: You can create your own DHCP name. If you are
using an IP address of 0.0.0.0, then the last option in Server configuration is
Change DHCP device name. This option allows you to change the DHCP
name to an alphanumeric name (LTX in our example).
Change DHCP device name (not set) ? (N) Y
Enter new DHCP device name : LTX
Numeric DHCP Name: You can change the DHCP name by specifying the
last octet of the IP address. When you use this method, the DHCP name is
LTXYY where YY is what you chose for the last octet of the IP address. If the
IP address you specify is 0.0.0.12, then the DHCP name is LTX12. This
method only works with 2 digit numbers (01-99).
WiBox™ User Guide
49
7: Setup Mode: Channel Configuration
This chapter explains how to configure the serial port.
Notes:
Current values display in parenthesis.
You must enter some values in hexadecimal notation. (See Error! Reference
source not found.Error! Reference source not found..)
Channel 1 (Option 1)
Select Channel 1 (option 1) from the Change Setup menu to define how the serial
port responds to network and serial communications. The following sections describe
the configurable parameters within the Channel configuration menu.
Figure 7-1. Serial Port Parameters
Baudrate
The unit and attached serial device, such as a modem, must agree on a speed or
baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200, 2400,
4800, 9600 (default), 19200, 38400, 57600, 115200, 230400, 460800, or 921600.
The current value is displayed in parentheses.
Baudrate (9600) ? _
WiBox™ User Guide
50
Configuration via Serial Mode or Telnet Port
I/F (Interface) Mode
The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation. The
default setting is 4C.
Note: RS-422 amd RS-485 are available on Channel 2 only.
I/F Mode (4C) ? _
The following table displays available I/F Mode options:
Note: All bit positions in the table that are blank represent “don’t care” bits
for that particular option, which can be set to either a 0 or 1 value.
Table 7-1. Interface Mode Options
I/F Mode Option
RS-422/485 4-wire
RS-485 2-wire
RS-232C
(1)
7 Bit
8 Bit
No Parity
Even Parity
Odd Parity
1 stop bit
2 stop bits(1)
(1) 2 stop bits are implemented by the software. This might influence performance.
The following table demonstrates some common I/F Mode settings:
Table 7-2. Common Interface Mode Settings
Common I/F Mode Setting
Binary
Hex
RS-232C, 8-bit, No Parity, 1 stop bit
0100 1100
4C
RS-232C, 7-bit, Even Parity, 1 stop bit
0111 1000
78
RS-485 2-wire, 8-bit, No Parity, 1 stop bit
0100 1111
4F
RS-422, 8-bit, Odd Parity, 1 stop bit
0101 1101
5D
Flow
Flow control sets the local handshaking method for stopping serial input/output. The
default setting is 00.
WiBox™ User Guide
51
Configuration via Serial Mode or Telnet Port
Flow (00) ? _
Use the following table to select flow control options:
Table 7-3. Flow Control Options
Flow Control Option
Hex
No flow control
00
XON/XOFF flow control
01
Hardware handshake with RTS/CTS lines
02
XON/XOFF pass characters to host
05
Port Number
The setting represents the source port number in TCP connections. It is the number
that identifies the channel for remote initiating connections.
Port No (10001) ? _
The default setting for Port 1 is 10001. The range is 1-65535, except for the following
reserved port numbers:
Table 7-4. Reserved Port Numbers
Port Numbers
Reserved for
1 – 1024
Reserved (well known ports)
9999
Telnet setup
14000-14009
Reserved for Redirector
30704
Reserved (77F0h)
30718
Reserved (77FEh)
Warning: We recommend that you not use the reserved port numbers
for this setting as incorrect operation may result.
Use Port 0 for the outgoing local port to change with each connection. The port range
is 50,000 to 59,999. Each subsequent connection increments the number by 1
(it wraps back around to 50,000).
Only use this automatic port increment feature to initiate a connection using TCP. Set
the port to a non-zero value when the unit is in a passive mode or when using UDP
instead of TCP.
Connect Mode
Connect Mode defines how the unit makes a connection, and how it reacts to
incoming connections over the network. The default setting is C0.
ConnectMode (C0) ? _
Enter Connect Mode options in hexadecimal notation.
WiBox™ User Guide
52
Configuration via Serial Mode or Telnet Port
Note: All bit positions in the table that are blank represent “don’t care” bits for
that particular option, which can be set to either a 0 or 1 value.
Table 7-5. Connect Mode Options
Connect Mode Option
a) Incoming Connection
Never accept incoming
Accept with DTR Active
Always Accept
b) Response
Nothing (quiet)
Character response (C=connect,
D=disconnect, N=unreachable)
c) Active Startup
No active startup
With any character
With DTR Active
With a specific start character
Manual connection
Autostart
Hostlist
d) Datagram Type
Directed UDP
e) Modem Mode
No Echo
Data Echo & Modem Response
(Numeric)
Data Echo & Modem Response
(Verbose)
Modem Response Only (Numeric)
Modem Response Only (Verbose)
a) Incoming Connection
Never Accept Incoming
WiBox™ User Guide
Rejects all external connection attempts.
53
Configuration via Serial Mode or Telnet Port
Accept with DTR Active
Accepts external connection requests only when the DTR input
is asserted. Cannot be used with Modem Mode.
Always Accept
Accepts any incoming connection when a connection is not
already established. Default setting.
b) Response
Character Response
A single character is transmitted to the serial port when there is a
change in connection state:
C = connected, D = disconnected, N = host unreachable.
Single character mode specifies the character response. The IP
address of the host connecting to the unit displays when the unit
is in verbose mode. This option is overridden when the Active
Start Modem Mode or Active Start Host List is in effect.
Default setting is Nothing (quiet).
c) Active Startup
No Active Startup
Does not attempt to initiate a connection under any
circumstance. Default setting.
With Any Character
Attempts to connect when any character is received from the
serial port.
With DTR Active
Attempts to connect when the DTR input changes from not
asserted to asserted.
With a Specific Start
Character
Attempts to connect when it receives a specific start character
from the serial port. The default start character is carriage return.
WiBox™ User Guide
54
Configuration via Serial Mode or Telnet Port
Manual Connection
Attempts to connect when directed by a command string
received from the serial port. The first character of the command
string must be a C (ASCII 0x43), and the last character must be
either a carriage return (ASCII 0x0D) or a line feed (0x0A). No
blanks or space characters may be in the command string.
Between the first and last command string characters must be a
full or partial destination IP address and may be a destination
port number.
The IP address must be in standard decimal-dot notation and
may be a partial address, representing the least significant 1, 2,
or 3 bytes of the remote IP address. The period is required
between each pair of IP address numbers.
If present, the port number must follow the IP address, must be
presented as a decimal number in the range 1-65535, and must
be preceded by a forward slash (ASCII 0x2F). The slash
separates the IP address and the port number. If you omit the
port number from a command string, the internally stored remote
port number starts a connection.
If a partial IP address is presented in a command string, it is
interpreted to be the least significant bytes of the IP address and
uses the internally stored remote IP address to provide the most
significant bytes of the IP address. If the IP address entered is
0.0.0.0/0, the device server enters Monitor Mode.
For example, if the remote IP address already configured in the
unit is 129.1.2.3, then an example command string would be
C3/7. (This would connect to 129.1.2.3 and port 7.) You may
also use a different ending for the connection string. For
example, C50.1/23 would connect you to 129.1.50.1 and port 23.
Figure 7-2. Manual Connection Address Example
Command String
Result if remote IP is 129.1.2.3 and remote port is 1234
C121.2.4.5/1
Complete override; connection is started with host 121.2.4.5,
port 1.
C5
Connects to 129.1.2.5, port 1234.
C28.10/12
Connects to 129.1.28.10, port 12.
C0.0.0.0/0
Enters Monitor Mode.
Autostart (Automatic
Connection)
If you enable Autostart, the unit automatically connects to the
remote IP address and remote port specified when the firmware
starts.
Hostlist
If you enable this option, the device server scrolls through the
hostlist until it connects to a device listed in the hostlist table.
Once it connects, the unit stops trying to connect to any others. If
this connection fails, the unit continues to scroll through the table
until it is able to connect to another IP in the hostlist.
Hostlist supports a minimum of 1 and a maximum of 12 entries
WiBox™ User Guide
55
Configuration via Serial Mode or Telnet Port
Each entry contains the IP address and the port number.
The hostlist is disabled for Manual and Modem Modes. The unit
does not accept a data connection from a remote device when
the hostlist option is enabled.
Figure 4-7. Hostlist Option
To enable the hostlist:
1. Enter a Connect Mode of 0x20 (2X), where X is any digit. The menu shows you
a list of current entries already defined in the product.
2. To delete, modify, or add an entry, select Yes. If you enter an IP address of
0.0.0.0, that entry and all others after it are deleted.
3. After completing the hostlist, repeat the previous step if necessary to edit the
hostlist again.
4. For Retrycounter, enter the number of times the Lantronix unit should try to
make a good network connection to a hostlist entry that it has successfully
ARPed. The range is 1-15, with the default set to 3.
5. For Retrytimeout, enter the number of seconds the unit should wait before
failing an attempted connection. The time is stored as units of milliseconds in the
range of 1-65535. The default setting is 250.
d) Datagram Type
Directed UDP
WiBox™ User Guide
When selecting this option, you are prompted for the Datagram type.
Enter 01 for directed or broadcast UDP.
56
Configuration via Serial Mode or Telnet Port
When the UDP option is in effect, the unit never attempts to initiate a
TCP connection because it uses UDP datagrams to send and receive
data.
e) Modem Mode
In Modem (Emulation) Mode, the unit presents a modem interface to the attached
serial device. It accepts AT-style modem commands and handles the modem signals
correctly.
Normally, there is a modem connected to a local PC and a modem connected to a
remote machine. A user must dial from the local PC to the remote machine,
accumulating phone charges for each connection. Modem Mode allows you to
replace modems with the WiBox, and to use an Ethernet connection instead of a
phone call. By not having to change communications applications, you avoid
potentially expensive phone calls.
To select Modem Mode, set the Connect Mode to C6 (no echo), D6 (echo with full
verbose), D7 (echo with numeric response), CF (modem responses only, numeric
response), or CE (modem responses only, full verbose).
Note: If the unit is in Modem Mode, and the serial port is idle, the unit can
still accept network TCP connections to the serial port if Connect Mode is set
to C6 (no echo), D6 (echo with full verbose), D7 (echo with numeric
response, CF (modem responses only, numeric response), or CE (modem
responses only, full verbose).
Without Echo
In Modem Mode, echo refers to the echo of all of the characters
entered in command mode; it does not mean to echo data that is
transferred. Quiet Mode (without echo) refers to the modem not
sending an answer to the commands received (or displaying what
was typed).
Data Echo & Modem
Response
Full Verbose: The unit echoes modem commands and responds to
a command with a message string shown in the table below.
Numeric Response: The unit echoes modem commands and
responds to a command with a numeric response.
Modem Responses
Only
Full Verbose: The unit does not echo modem commands and
responds to a command with a message string shown in the table
below.
Numeric Response: The unit does not echo modem commands
and responds to a command with a numeric response.
Table 4-11. Modem Mode Messages
Message
Meaning
Full Verbose
OK
Command was executed without error.
CONNECT
A network connection has been established.
NO CARRIER
A network connection has been closed.
WiBox™ User Guide
57
Configuration via Serial Mode or Telnet Port
Message
Meaning
RING n.n.n.n.
A remote device, having IP address n.n.n.n, is connecting to this
device.
Numeric Response
OK
Connected
Ring
No Carrier
Error
Received commands must begin with the two-character sequence AT and be
terminated with a carriage return character.
The unit ignores any character sequence received not starting with AT, and only
recognizes and processes single AT-style commands. The unit treats compound AT
commands as unrecognized commands.
If the Full Verbose option is in effect, the unit responds to an unrecognized
command string that is otherwise formatted correctly (begins with AT and ends with
carriage return) with the "OK" message and takes no further action.
If the Numeric Response option is in effect, the unit responds to an unrecognized
command string that is otherwise formatted correctly with the "OK" message and
takes no further action.
When an active connection is in effect, the unit transfers data and does not process
commands received from the serial interface.
When a connection is terminated or lost, the unit reverts to command mode.
When an active connection is in effect, the unit terminates the connection if it
receives the following sequence from the attached serial device:
No serial data is received for one second.
The character sequence +++ is received, with no more than one second
between each two characters.
No serial data is received for one second after the last + character. At this
time, the unit responds affirmatively per the selected echo/response mode.
The character string ATH is received, terminated with a carriage return. The
unit responds affirmatively according to the selected echo/response mode
and drops the network connection. The serial interface reverts to accepting
command strings.
If this sequence is not followed, the unit remains in data transfer mode.
7-6. Modem Mode Commands
Modem Mode
Command
Function
ATDTx.x.x.x,pppp or
ATDTx.x.x.x/pppp
Makes a connection to an IP address (x.x.x.x) and a remote port
number (pppp).
WiBox™ User Guide
58
Configuration via Serial Mode or Telnet Port
Modem Mode
Command
Function
ATDTx.x.x.x
Makes a connection to an IP address (x.x.x.x) and the remote port
number defined within the unit.
ATD0.0.0.0
Forces the unit into Monitor Mode if a remote IP address and port
number are defined within the unit.
ATD
Forces the unit into Monitor Mode if a remote IP address and port
number are not defined within the unit.
ATDx.x.x.x
Makes a connection to an IP address (x.x.x.x) and the remote port
number defined within the unit.
ATH
Hangs up the connection (Entered as +++ATH ).
ATS0=n
Enables or disables connections from the network going to the serial
port.
n=0 disables the ability to make a connection from the network to
the serial port.
n=1-9 enables the ability to make a connection from the network to
the serial port.
n>1-9 is invalid.
ATEn
Enables or disables character echo and responses.
n=0 disables character echo and responses.
n=1 enables character echo and responses.
ATVn
Enables numeric response or full verbose.
n=0 enables numeric response.
n=1 enables full verbose.
Note: The unit recognizes these AT commands as single commands such as
ATE0 or ATV1; it does not recognize compound commands such as ATE0V.
Send the Escape Sequence (+++) in Modem Mode
Send ‘+++’ in Modem Mode (Y) ? _
Disable or enable the WiBox’s ability to send the escape sequence. The default
setting is Y (Yes) (send the escape sequence).
Auto Increment Source Port
Auto increment source port (N) ? _
Y (Yes) auto increment the source port. The WiBox increments the port number used
with each new connection.
Remote IP Address
This is the destination IP address used with an outgoing connection.
Remote IP Address : (000) (000) (000) (000)_
WiBox™ User Guide
59
Configuration via Serial Mode or Telnet Port
Note: This option does not display when Hostlist is enabled from the
ConnectMode prompt (see Connect Mode on page 52 for more information).
Remote Port
You must set the remote TCP port number for the unit to make outgoing connections.
This parameter defines the port number on the target host to which a connection is
attempted.
Remote Port (0) ? _
To connect an ASCII terminal to a host using the unit for login purposes, use the
remote port number 23 (Internet standard port number for Telnet services).
Note: This option does not display when Hostlist is enabled from the
ConnectMode prompt (see Connect Mode on page 52 for more information).
DisConnMode
This setting determines the conditions under which the unit will cause a network
connection to terminate. The default setting is 00.
DisConnMode (00) ? _
Notes:
In DisConnMode (Disconnect Mode), DTR drop either drops the connection
or is ignored.
Note: All bit positions in the table that are blank represent “don’t care” bits for
that particular option, which can be set to either a 0 or 1 value.
Table 7-7. Disconnect Mode Options
Disconnect Mode Option
(6)
Disconnect with DTR drop
Ignore DTR
Telnet mode and terminal type setup (1)
Channel (port) password (2)
Hard disconnect (3)
Disable hard disconnect
State LED off with connection (4)
Disconnect with EOT (^D)
(5)
(1) The WiBox sends the "Terminal Type" upon an outgoing connection.
(2) A password is required for a connection to the serial port from the network.
(3) The TCP connection closes even if the remote site does not acknowledge the disconnection.
(4) When there is a network connection to or from the serial port, the state LED turns off instead of blinking.
(5) When Ctrl+D or Hex 04 is detected, the connection is dropped. Both Telnet Mode and Disconnect with
EOT must be enabled for Disconnect with EOT to function properly. Ctrl+D is only detected going from
the serial port to the network.
(6) When DTR transitions from a high state to a low state, the network connection to or from the serial port
drops.
WiBox™ User Guide
60
Configuration via Serial Mode or Telnet Port
Flush Mode (Buffer Flushing)
Using this parameter, you can control line handling and network buffers with
connection startup and disconnect. The default setting is 00.
FlushMode (00) ? _
You can also select between two different packing algorithms.
Note: All bit positions in the table that are blank represent “don’t care” bits for
that particular option, which can be set to either a 0 or 1 value.
Table 7-8. Flush Mode Options
Function
Input Buffer (Serial to Network)
Clear with a connection initiated from the device to the network
Clear with a connection initiated from the network to the device
Clear when the network connection to or from the device is disconnected
Output Buffer (Network to Serial)
Clear with a connection initiated from the device to the network
Clear with a connection initiated from the network to the device
Clear when the network connection to or from the device is disconnected
Alternate Packing Algorithm (Pack Control)
Enable
Pack Control
The packing algorithms define how and when packets are sent to the network. The
standard algorithm is optimized for applications in which the unit is used in a local
environment, allowing for very small delays for single characters, while keeping the
packet count low. The alternate packing algorithm minimizes the packet count on the
network and is especially useful in applications in a routed Wide Area Network
(WAN). Adjusting parameters in this mode can economize the network data stream.
Pack control settings are enabled in Flush Mode. Set this value to 00 if you do not
need specific functions.
Note: All bit positions in the table that are blank represent “don’t care” bits for
that particular option, which can be set to either a 0 or 1 value.
Table 7-9. Pack Control Options
Option
Packing Interval
Interval: 12 msec
WiBox™ User Guide
61
Configuration via Serial Mode or Telnet Port
Option
Interval: 52 msec
Interval: 250 msec
Interval: 5 sec
Trailing Characters
None
One
Two
Send Characters
2-Byte Send Character Sequence
Send Immediately After Send chars
Packing Interval
Packing Interval defines how long the unit should wait before sending accumulated
characters. This wait period is between successive network segments containing
data. For alternate packing, the default interval is 12 ms.
Trailing Characters
In some applications, CRC, Checksum, or other trailing characters follow the end-ofsequence character; this option helps to adapt frame transmission to the frame
boundary. The default setting is 00 (none).
Send Characters
If 2-Byte Send Character Sequence is enabled, the unit interprets the
sendchars as a 2-byte sequence; if this option is not enabled, the unit
interprets them independently. The default setting is 0 (disabled).
If Send Immediately After Characters is not set, any characters already in
the serial buffer are included in the transmission after a "transmit" condition is
found. If this option is set, the unit sends immediately after recognizing the
transmit condition (sendchar or timeout). The default setting is 0.
Note: A transmission might occur if status information needs to be
exchanged or an acknowledgment needs to be sent.
DisConnTime (Inactivity Timeout)
Use this parameter to set an inactivity timeout. The unit drops the connection if there
is no activity on the serial line before the set time expires. Enter time in the format
mm:ss, where m is the number of minutes and s is the number of seconds.
DisConnTime (00:00) ?:
To disable the inactivity timeout, enter 00:00. Range is 0 (disabled) to 5999 seconds
(99 minutes, 59 seconds). The default setting is 0.
WiBox™ User Guide
62
Configuration via Serial Mode or Telnet Port
Send Characters
Enter up to two characters in hexadecimal representation in sendchar.
SendChar 1 (00) ? _
SendChar 2 (00) ? _
If the unit receives a character on the serial line that matches one of these
characters, it sends the character immediately, along with any awaiting characters, to
the TCP connection. This action minimizes the response time for specific protocol
characters on the serial line (for example, ETX, EOT). Setting the first sendchar to 00
disables the recognition of the characters. Alternatively, the unit can interpret two
characters as a sequence (see Pack Control on page 61). The default setting is 00.
Telnet Terminal Type
This parameter displays only if you enabled the terminal type option in Disconnect
Mode. With this option enabled, you can use the terminal name for the Telnet
terminal type. Enter only one name.
With terminal type option enabled, the unit also reacts to the EOR (end of record) and
binary options, useful for applications like terminal emulation to IBM hosts.
Channel (Port) Password
This parameter displays only if the channel (port) password option is enabled in
Disconnect Mode. With this option enabled, you can set a password on the serial
port. The default setting is all 0s.
WLAN Settings
Without adequate protection, a wireless LAN is susceptible to access by
unauthorized users. WiBox features the WPA security standard, based on
IEEE802.11i and IEEE802.1X. WEP is provided for backwards compatibility and
interaction with older devices.
Without adequate protection, a wireless LAN is susceptible to access by
unauthorized users.
The WiBox WLAN Settings menu permits the following actions:
Configuration of the wireless network profile available for activation.
Configuration of the wireless network security settings.
Configuration of advanced settings such as radio power management.
NOT IN COBOS MASTER:
Note: Due to regulations, the country-specific setting has been removed from the
setup menu and Web-Manager. We do, however, provide a separate utility for
changing the Country/Zone setting. The utility is called SetZone and is included in
the package. It is also available for download from the Lantronix web site.
The syntax is: SetZone  []
Leaving the zone blank causes the utility to report the current setting only. Following
are valid zone abbreviations. These settings are consistent with IEEE802.11b/G
zones:
WiBox™ User Guide
63
Configuration via Serial Mode or Telnet Port
US=United States and Canada
FR=France
JP=Japan
OT=Others, such as Europe (excluding
France), Asia, Africa, and Australia
To modify WLAN settings, select 4 WLAN from the Change Setup menu.
Enable WLAN
Enable the Ethernet or the Wireless interface. When WLAN is enabled, the Ethernet
interface is disabled.
Enable WLAN (Y) ? _
Topology
Select Infrastructure or Adhoc. Infrastructure (ESS) mode communicates with
Access Points. Ad Hoc (IBSS) mode communicates only with other clients.
Topology 0=Infrastructure, 1=Adhoc (0) ?
Network Name (SSID)
Enter the name of the network to which the WiBox will connect.
Network name (LTRX_IBSS) ? _
Ad Hoc Network Creation Channel
When Adhoc mode is selected and the WiBox cannot find the specified network, it
creates one with that name by transmitting a beacon on the selected channel.
Channel (11) ?
Only channels allowed in the country for which the WiBox is designated can be
selected. The country displays in the settings overview.
Security
The WiBox features WEP and WPA to secure all wireless communication. If Adhoc
is selected as topology, only WEP is available
Security 0=none, 1=WEP, 2=WPA (0) ? _
WEP
Authentication 0=open/none, 1=shared (0) ? _
Encryption 0=WEP64, 1=WPE128 (0) ?
Display current key (N) ?
Change key (N) ?
Key type 0=hex, 1=passphrase (0) ?
Enter key:
Authentication selects whether the encryption keys are matched (1 = shared) with
those of the communication partner before passing through messages or not
(2 = open/none).
The Encryption prompt requests the length of the encryption key and the security
strength. WEP64 is 5 bytes or 40 bits (option 0). WEP128 is 13 bytes or 104 bits
(option 1).
WiBox™ User Guide
64
Configuration via Serial Mode or Telnet Port
Select (Y) Yes at the Display current key prompt to show the currently configured
key/passphrase
Change key permits modifying the currently configured key by selecting (Y) Yes.
The Key type requests whether the new key is in hexadecimal or passphrase format.
Enter key prompts for the new encryption key. The passphrase input is not the same
as ASCII input (as used on other products). ASCII is translated directly into
hexadecimal bytes according to the ASCII table. The WiBox passphrase is hashed
using the Neesus Datacom algorithm (for WEP64) or MD5 (for WEP128).
The passphrase input is safer because it is up to 63 chars long. ASCII input is a
maximum of 5 (WEP64) or 13 (WEP128) characters long and limits the number of
key combinations.
Please refer to the other equipment’s manual to determine the passphrase input style
recommended.
Note: Lantronix recommends using a passphrase of 20 characters or more
for maximum security.
WPA
This firmware version allows only Pre-Shared Keys (PSK) for authentication and
encryption.
Allow WEP group keys (N) ?
Display current key (N) ?
Change key (N) ?
Key type 0=hex, 1=passphrase (1) ?
Enter key: () ?
Selecting (Y) Yes at the Allow WEP group keys prompt enables the reception of
broadcast messages if older WEP equipment shares the same Access Point.
Select (Y) Yes at the Display current key prompt to show the currently configured
key/passphrase
Change key permits modifying the currently configured key by selecting (Y) Yes.
The Key type requests whether the new key is in hexadecimal or passphrase format.
Enter key prompts for the new encryption key. The passphrase input is not the same
as ASCII input (as used on other products). ASCII is translated directly into
hexadecimal bytes according to the ASCII table. The WiBox passphrase is hashed
using the Neesus Datacom algorithm (for WEP64) or MD5 (for WEP128).
The passphrase input is safer because it is up to 63 chars long. ASCII input is a
maximum of 5 (WEP64) or 13 (WEP128) characters long and limits the number of
key combinations.
Please refer to the other equipment’s manual to determine the passphrase input style
recommended.
Note: Lantronix recommends using a passphrase of 20 characters or more
for maximum security.
Data Rate
WiBox permits the control of the transmission rate. Lower data rates allow for larger
distances. It may also be needed to communicate with older devices. Select 0 - 3 to
set a fixed data rate or select 4 - 6 to set a maximum data rate. This allows the radio
to lower the data rate in case of bad link quality.
WiBox™ User Guide
65
Configuration via Serial Mode or Telnet Port
Data rate, Only : 0=1, 1=2, 2=5.5, 3=11 Mbps or
Up to: 4=2, 5=5.5, 6=11 Mbps (6) ?
Enable Power Management
This allows the software to turn off the radio when expecting not to receive or
transmit soon. This feature reduces the power consumption by up to 170 mA.
Enabling power management increases the response time, because the radio needs
to start up again. The radio regularly starts to synchronize and check for incoming
messages.
Enable power management (N) ? _
WiBox™ User Guide
66
8: Setup Mode: Advanced Settings
Expert Settings (Option 5)
Note: You can change these settings using Telnet or serial connections only,
not on the Web-Manager.
Caution: Only an expert should change these parameters. You must
definitely know the consequences the changes might have.
Figure 8-1. Expert Settings NEED NEW
The default settings are listed below:
TCP Keepalive time in s
(1s – 65s; 0s=disable)
45
ARP Cache timeout in s
(1s – 600s)
600
Enable High Performance
Disabled (applies to Product Name-03, Product
Name-485, and later units only)
Disable Monitor Mode @ bootup
Enabled
HTTP Port Number
(1-65535)
80
SMTP Port Number
(1-65535)
25
MTU Size (512 – 1400)
0 (resulting in an operational value of 1400)
Enable alternate MAC
Disabled (OEM use only)
Ethernet connection type
0 (resulting in auto-negotiation)
WiBox™ User Guide
67
Configuration via Serial Mode or Telnet Port
TCP Keepalive time in seconds
This option allows you to change how many seconds the unit waits during a silent
connection before attempting to see if the currently connected network device is still
on the network. If the unit gets no response, it drops that connection. The default
setting is 45.
TCP Keepalive time in s (1s – 65s; 0s=disable): (45)? _
ARP Cache timeout in seconds
Whenever the unit communicates with another device on the network, it adds an
entry into its ARP table. The ARP Cache timeout option allows you to define how
many seconds (1-600) the unit will wait before timing out this table. The default
setting is 600.
ARP Cache timeout in s (1s – 65s; 0s=disable): (600)? _
Enable High Performance
This option applies to Product Name-03 and later units only. It allows you to increase
the CPU performance required to use the higher baud rates on the serial interface
(460 Kbps and 920 Kbps). The standard CPU performance mode supports up to
230400 Kbps.
Enable High Performance (N)?
Notes:
If a baud rate of 460 Kbps or 920 Kbps is set and the high performance mode is
disabled, the operation of the serial channel would be out of the specified error
tolerance, thereby leading to inconsistent speed settings on the two ends of the
serial channel.
Increasing CPU clock speed consumes more power and generates more heat.
This reduces the maximum operating temperature specification. See the
appropriate product brief for details.
Disable Monitor Mode at bootup
This option allows you to disable all entries into Monitor Mode during startup, except
for the ‘xxx’ sequence. This prevents entry using yyy, zzz, xx1, and yy1 key
sequences (only during the bootup sequence). The default for Monitor Mode at
bootup is N (No). (See 10:Monitor Mode.)
Disable Monitor Mode @ bootup (N) ? _
HTTP Port Number
This option allows the configuration of the web server port number. The valid range is
1-65535.The default HTTP port number is 80.
HTTP Port Number : (80) ? _
SMTP Port Number
This option allows the configuration of the email port number. The valid range is
1-65535. The default SMTP port number is 25.
SMTP Port Number : (25) ? _
WiBox™ User Guide
68
Configuration via Serial Mode or Telnet Port
Note: When configuring the HTTP or SMTP port number, take note of the
‘reserved’ port numbers on page 52.
MTU Size
The Maximum Transmission Unit (MTU) is the largest physical packet size a network
can transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default
setting is 1400 bytes.
MTU Size: (1400) ? _
Ethernet Connection Type
The Product Name allows for the Ethernet speed and duplex to be manually
configured. Enter 0 for auto-negotiation (default). To select the speed and duplex,
enter one of the following: 2 (10Mbit/half duplex), 3 (10Mbit/full duplex),
4 (100Mbit/half duplex), or 5 (100Mbit/full duplex).
Ethernet connection type: (0) ? _
Configurable Server Port Number
The host attached to the WiPort may communicate with other CoBos devices on the
wireless network using the Lantronix Configuration Access Protocol (LCAP). This
service is available on server port number 0x77FE (30718) and is fixed. When the
WiPort is in bridging mode, the LCAP port number is modifiable so that the LCAP
service is available on the wired interface for WiPort configuration.
For more information on bridging, see 9:Wireless Bridging.
Config Server Port Number: (30718) ? _
Security Settings
Security settings can only be changed via the setup menu, through a Telnet or serial
connection.
Note: As recommended, set security over the dedicated network or over the
serial setup. If the parameters are set over the network (Telnet 9999),
someone else could capture these settings.
Caution: Disabling both Telnet Setup and Port 77FE prevents users
from accessing the setup menu from the network.
Disable SNMP
For security purposes, disable SNMP (if required) on the WiBox unit. The current
setting displays in parentheses.
Disable SNMP (N) ? _
SNMP Community Name
The SNMP Community Name is a required field for NMS to read or write to a device.
Enter a string of 1 to 13 characters.
SNMP Community Name (public): _
WiBox™ User Guide
69
Configuration via Serial Mode or Telnet Port
The default entry is public. The current value displays in parentheses.
Disable Telnet Setup
Note: Disabling both Telnet Setup and Port 77FE prevents users from
accessing the setup menu from the network.
This setting defaults to the N (No) option. The Y (Yes) option disables access to
Setup Mode by Telnet (port 9999). It only allows access locally via the web pages
and the serial port of the unit.
Disable Telnet Setup (N) ? _
Disable TFTP Firmware Upgrade
This setting defaults to the N (No) option. The Y (Yes) option disables TFTP for
network firmware upgrades.
Disable TFTP Firmware Update (N) : _
Disable Port 77FE (Hex)
Note: Disabling both Telnet Setup and Port 77FE and web setup prevents
users from accessing the setup from the network.
Port 77FE is used by Web-Manager and custom programs to configure the unit
remotely. If required, disable this capability for security purposes.
Disable Port 77FEh (N) ? _
The default setting is the N (No) option, which enables remote configuration. As a
result, configure the unit by using web pages, Telnet, or serial configuration.
The Y (Yes) option disables remote configuration and web sites.
Note: The Y (Yes) option disables many of the GUI tools for configuring the
unit, including the embedded Web-Manager tool.
Disable Web Server
The Y (Yes) option disables the web server. This setting defaults to the N (No)
option. Disabling the web server also disables the web setup.
Disable Web Server (N) ? _
Disable Web Setup
The Y (Yes) option disables configuration via the Web-Manager (but the web server
remains active for custom web pages). This setting defaults to the N (No) option.
Disable Web Setup (N) ? _
Disable ECHO Ports
This setting controls whether the serial port echoes characters it receives. The
current value displays in parentheses.
Disable ECHO ports (Y) ? _
Enable Enhanced Password
WiBox™ User Guide
70
Configuration via Serial Mode or Telnet Port
This setting defaults to the N (No) option, which permits a 4-character password
protecting Setup Mode by means of Telnet and web pages.
Enable Enhanced Password (Y) ? _
The Y (Yes) option allows an extended security password of 16-characters for
protecting Telnet access.
Enable Encryption
Rijndael is the block cipher algorithm chosen by the National Institute of Science and
Technology (NIST) as the Advanced Encryption Standard (AES) to be used by the
US government. The WiBox supports 128-, 192-, and 256-bit encryption key lengths.
Note: Configuring encryption should be done through a local connection to
the serial port of the WiBox, or via a secured network connection. Initial
configuration information including the encryption key is sent in clear text
over the network.
To configure AES encryption on the WiBox:
Figure 8-2. Encryption Keys
1. When prompted to enable encryption, select Y.
2. Enter the encryption key length when prompted. The WiBox supports 128-, 192-,
and 256-bit encryption key lengths.
3. When prompted to change keys, select Y.
4. At the Enter Keys prompt, enter your encryption key. The encryption keys are
entered in hexadecimal. The hexadecimal values are echoed as asterisks to
prevent onlookers from seeing the key. Hexadecimal values are 0-9 and A-F.
For a 128-bit key length, enter 32 hexadecimal characters.
For a 192-bit key length, enter 48 hexadecimal characters.
For a 256-bit key length, enter 64 hexadecimal characters
5. Continue pressing Enter until you return to the Change Setup menu.
6. From the Change Setup menu, select option 9 to save and exit.
Encryption only applies to the port selected for data tunneling (default 10001),
regardless of whether you are using TCP or UDP.
Generally, one of three situations applies:
Encrypted WiBox-to-WiBox communication. Be sure to configure both WiBox
devices with the same encryption key.
Third-party application to WiBox-encrypted communication: WiBox uses
standard AES encryption protocols. To communicate successfully, products
and applications on the peer side must use the same protocols and the same
encryption key as the WiBox.
WiBox™ User Guide
71
Configuration via Serial Mode or Telnet Port
Lantronix Secure Com Port Redirector provides an encrypted connection
from Windows-based applications to the WiBox. Information about SCPR is
at http://www.lantronix.com/device-networking/software-services/scpr.html
A 30-day trial version of SCPR is included on the CD.
Default Settings
Select 7 Default Settings from the Change Setup menu to reset the unit’s Channel 1
configuration, Channel 2 configuration, and Expert settings to the factory default
settings. The server configuration settings for IP address, gateway IP address,
netmask, and WLAN remain unchanged. The specific settings that this option
changes are listed below:
Channel 1 Configuration CHECK THESE
Baudrate
9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C)
Port No
10001
Connect Mode
C0 (always accept incoming connection; no active
connection startup)
Hostlist Retry Counter
Hostlist Retry Timeout
250 (msec)
Send Character
0x0D (CR)
All other parameters
Channel 2 Configuration
Baudrate
9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C)
Port No
10002
Connect Mode
C0 (always accept incoming connection; no active
connection startup)
Hostlist Retry Counter
Hostlist Retry Timeout
250 (msec)
Send Character
0x0D (CR)
All other parameters
Expert Settings
TCP keepalive
45 (seconds)
ARP cache timeout
600 (seconds)
High CPU performance mode
Disabled
WiBox™ User Guide
72
Configuration via Serial Mode or Telnet Port
Disable Monitor Mode
(N) No
HTTP port number
0 (resulting in an operational value of 80)
Security Settings
Disable SNMP
(N) No
SNMP Community Name
public
Disable Telnet Setup
(N) No
Disable TFTP Firmware Update
(N) No
Disable Port 77FEh
(N) No
Disable Web Server
(N) No
Disable Web Setup
(N) No
Disable ECHO ports
(Y) Yes
Enable Encryption
(N) No
Enable Enhanced password
(N) No
Exit Configuration Mode
To exit setup mode, do one of the following:
To save all changes and reboot the device, select option 9 Save and exit
from the Change Setup menu.
or
To exit the configuration mode without saving any changes or rebooting,
select option 8 Exit without save from the Change Setup menu.
WiBox™ User Guide
73
9: Wireless Bridging
The WiBox2100E supports wireless bridging. This allows a host, connected on the
WiBox’s wired Ethernet interface, to be accessible over the wireless network (via the
WiBox).
To initialize the bridging feature:
1. Configure the WiBox’s wireless settings. See WLAN Configuration on page 40.
2. Enable bridging in Serial Mode. See Network Mode on page 47.
3. Set up the wired host connected to the WiBox’s Ethernet port.
Configuring the WiBox in Bridging Mode
Once in bridging mode, the services on the WiBox are available only through the
wired interface. There are three methods for configuring the WiBox when in bridging
mode.
Method 1
This method uses the current Ethernet wired host to configure the WiBox. This
requires the modification of the wired host’s IP address as well as the following steps:
1. Use a utility to locate the WiBox’s MAC address and auto-IP address. This utility
must use the Lantronix access protocol to query the WiBox.
2. Assign a static auto-IP address to the wired host within the same subnet as the
WiBox.
3. Use the WiBox’s Web-Manager or Telnet to port 9999 to configure the WiBox as
necessary.
4. Configure the wired host’s IP address back to the original IP address
configuration.
Method 2
This method requires the current wired host to be disconnected temporarily. Another
device physically connects to the WiBox’s wired interface for configuration.
1. Disconnect the current wired host from the WiBox and connect the device used for
configuring the WiBox.
2. Use a utility to locate the WiBox’s MAC address and auto-IP address. This utility
must use the Lantronix access protocol to query the WiBox.
3. Assign a static auto-IP address to the wired host within the same subnet as the
WiBox.
4. Use the WiBox’s Web-Manager or Telnet to port 9999 to configure the WiBox as
necessary.
5. Disconnect the wired device and reconnect the original wired host to the WiBox.
WiBox™ User Guide
74
Wireless Bridging t
Method 3
As an alternative to configuring through the wired interface, connect a device through
the WiBox’s serial port. For more information on configuration through the serial port,
see 5: Telnet or Serial Port (Setup Mode) Configuration.
WiBox™ User Guide
75
10: Monitor Mode
Monitor Mode is a command-line interface used for diagnostic purposes. There are
two ways to enter Monitor Mode: locally via the serial port or remotely via the
network.
Entering Monitor Mode via the Serial Port
To enter Monitor Mode locally:
1. Follow the same steps used for setting the serial configuration parameters (see 5:
Telnet or Serial Port (Setup Mode) Configuration).
2. Instead of typing three x keys, however:
a) Type zzz to enter Monitor Mode with network connections.
b) Type yyy to enter Monitor Mode without network connections.
A 0> prompt indicates that you have successfully entered Monitor Mode.
Entering Monitor Mode via the Network Port
To enter Monitor Mode using a Telnet connection:
1. Establish a Telnet session to the configuration port (9999). The following message
displays
: MAC address 00204A0113A3
Software version 05.3 (040129) WBX
Press Enter to go into Setup Mode
2. Type M (upper case).
A 0> prompt indicates that you have successfully entered Monitor Mode.
Monitor Mode Commands
The following commands are available in Monitor Mode.
Note: All commands must be in capital letters.
Table 10-1. Monitor Mode Commands
Command
Command Name
Function
VS
Version
Queries software header record (16 bytes) of unit.
GC
Get Configuration
Gets configuration of unit as hex records (120
bytes).
SC
Send Configuration
Sets configuration of unit from hex records.
WiBox™ User Guide
76
Monitor Mode t
Command
Command Name
Function
PI x.x.x.x
Ping
Pings unit with IP address x.x.x.x to check device
status.
AT
ARP Table
Shows the unit’s ARP table entries.
TT
TCP Connection
Table
Shows all incoming and outgoing TCP connections.
NC
Network Connection
Shows the unit’s current IP address.
RS
Reset
Resets the unit.
QU
Quit
Exits diagnostics mode.
G0, G1, ....,Ge, Gf
Get configuration
from memory page
Gets a memory page of configuration information
from the device.
S0, S1,...,Se, Sf
Set configuration to
memory page
Sets a memory page of configuration information
on the device.
GM
Get MAC address
Shows the unit's 6-byte MAC.
SS
Set Security record
Sets the Security record without the encryption key
and length parameters. The entire record must still
be written, but the encryption-specific bytes do not
need to be provided (they can be null since they
are not overwritten).
Responses to some of the commands are given in Intel Hex format.
Note: Entering any of the commands listed above generates one of the
following command response codes:
Table 10-2. Command Response Codes
WiBox™ User Guide
Response
Meaning
0>
OK; no error
1>
No answer from remote device
2>
Cannot reach remote device or no answer
8>
Wrong parameter(s)
9>
Invalid command
77
11: Updating Firmware
This chapter explains how to obtain and update the unit’s firmware.
Reloading Firmware
There are several ways to update the unit’s internal operational code (*ROM) via
TFTP or via the serial port. You can also update the unit’s internal web interface
(*COB) via TFTP.
Here are typical names for those files. Check the Lantronix web site for the latest
versions and release notes.
Table 11-1. Firmware Files
ROM File
COB
WBXxxx.ROM
WBXvx_x.COB (Web-Manager)_WNxxx.COB (Web-Manager)
Network Upgrade
Use the command: tftp –i  put  W5 or
the Device Installer upgrade feature. DI 4.0.0.4 and later support the W5 destination
file.
Serial Upgrade
Use the Advanced Recovery feature of DeviceInstaller 4.0.0.4 and later as instructed
in the DeviceInstaller Online Help.
Web Pages
Due to the extra space taken by the firmware, the number of web pages has been
reduced from 28 to 19.
Also, the start of the web pages has been moved in FLASH, requiring a reload of any
loaded web pages after the firmware upgrade. Follow regular TFTP or DeviceInstaller
procedures.
WLAN Country Setting
Due to regulations, the country-specific setting has been removed from the setup
menu and Web-Manager. We do, however, provide a separate utility for changing the
Country/Zone setting. The utility is called SetZone and is included in the package. It
is also available for download from the Lantronix web site.
WiBox™ User Guide
78
Updating Firmware
The syntax is: SetZone  []
Leaving the zone blank causes the utility to report the current setting only. Following
are valid zone abbreviations. These settings are consistent with IEEE802.11b/G
zones:
US=United States and Canada
FR=France
JP=Japan
OT=Others, such as Europe (excluding
France), Asia, Africa, and Australia
THE FOLLOWING IS WHAT WE HAVE IN THE COBOS MASTER:
Obtaining Firmware
You can obtain the most up-to-date firmware and release notes for the unit from the
Lantronix web site (www.lantronix.com) or by using anonymous FTP
(ftp.lantronix.com).
Reloading Firmware
Note: For details on upgrading to version 6.1.0.0 from pre-6.1.0.0, see the Product
Name Upgrade Notice on the Lantronix ftp site (ftp.lantronix.com).
There are several ways to update the unit's internal operational code (*.ROM): using
DeviceInstaller (the preferred way), using TFTP, or using the serial port. You can also
update the unit's internal Web interface (*.COB) using TFTP or DeviceInstaller.
Here are typical names for those files. Check the Lantronix web site for the latest
versions and release notes.
Table 11-2. Firmware Files
ROM File
COB
XPT_6100.rom
XPT_webm_1300.cob
Please refer to the DeviceInstaller online Help for information about reloading
firmware using DeviceInstaller. The other methods are discussed below.
Using TFTP: Graphical User Interface
To download new firmware from a computer:
1. Use a TFTP client to send a binary file to the unit (*.ROM to upgrade the unit's
internal operational code and *.COB to upgrade its internal Web interface).
Note: TFTP requires the .ROM (binary) version of the unit's internal
operational code.
2. In the TFTP server field, enter the IP address of the unit being upgraded.
3. Select Upload operation and Binary format.
4. Enter the full path of the firmware file in the Local file name field.
5. In the Remote file name field, enter the current internal operational code or
WEB1 to WEB6 for the internal Web interface.
For firmware releases 6.1 and later, the TFTP destination files for Product Name01, Product Name-03, and Product Name 485 are X4, X5, and X6, respectively.
WiBox™ User Guide
79
Updating Firmware
For firmware 1.8 and earlier, the TFTP destination files for Product Name-01,
Product Name-03, and Product Name 485 are X1, X2, and X3, respectively.
6. Click the Upload Now button to transfer the file to the unit.
Figure 11-1. TFTP Window
After the firmware has been loaded and stored, which takes approximately 8
seconds, the unit performs a power reset. Using TFTP: Command Line Interface
To download new firmware from a computer:
1.
Enter the following from a TFTP command line interface:
tftp –i  put  
The following examples demonstrate the TFTP command sequence to download
the .rom file and the .cob file:
tftp –i 192.168.1.111 put XPT_6100.rom X4
tftp –i 192.168.1.111 put XPT_webm_1300.cob WEB4
2. In the Remote file name field, enter the current internal operational code or
WEB1 to WEB6 for the internal Web interface.
For firmware releases 6.1 and later, the TFTP destination files for Product Name01, Product Name-03, and Product Name 485 are X4, X5, and X6, respectively.
For firmware 1.8 and earlier, the TFTP destination files for Product Name-01,
Product Name-03, and Product Name 485 are X1, X2, and X3, respectively.
WiBox™ User Guide
80
Updating Firmware
Recovering the Firmware Using the Serial Port and DeviceInstaller
If for some reason the firmware is damaged, you can recover the firmware file by
using DeviceInstaller to download the *.ROM file over the serial port.
To recover firmware:
1. Start DeviceInstaller. If your PC has more than one network adapter, a message
displays. Select an adapter and click OK.
2. From the Tools menu, select Advanced/Recover Firmware. The Serial Port
Firmware Upgrade window displays.
3. For Port on PC, enter the COM port on the PC that is connected to the serial
port of the Lantronix unit.
4. For Device Model, be sure the appropriate Product Name device is shown
(Product Name-01, Product Name-03, or XP485).
5. For Firmware File, click the Browse button and go to the location where the
firmware file resides.
Note: Make sure the Product Name on which you are recovering firmware is
connected to this selected port on your PC.
6. Click OK to download the file.
7. When prompted, reset the device. Status messages and a progress bar at the
bottom of the screen show the progress of the file transfer. When the file transfer
completes, the message “Successful, Click OK to Close” appears.
8. Click the OK button to complete this procedure.
Note For more information, see Recovering Firmware in the DeviceInstaller
online Help.
WiBox™ User Guide
81
12: Troubleshooting
This chapter discusses how you can diagnose and fix errors quickly without having to
contact a dealer or Lantronix. It helps to connect a terminal to the serial port while
diagnosing an error to view summary messages that may be displayed. When
troubleshooting, always ensure that the physical connections (power cable, network
cable, and serial cable) are secure.
Note: Some unexplained errors might be caused by duplicate IP addresses on the
network. Make sure that your unit's IP address is unique.
Diagnostic LED States
Condition
Channel 1 Status LED
Network controller error
Blink 3x/4 seconds
Serial number storage
checksum error
Blink 4x/4 seconds
Duplicate IP address present
Blink 5x/4 seconds
No DHCP response
Blink 5x/4 seconds
Setup menu active
Blink 2x/second for 2 seconds, off
for 2 seconds
Problems and Error Messages
Problem/Message
Reason
Solution
Cannot establish an
Infrastructure network
connection to the WiBox.
Network Name (SSID) in the
WiBox is not set or does not
match the Access Point (AP).
Verify Network Name (SSID) for
the WiBox and AP are exactly the
same. These are case-sensitive.
The AP has WEP encryption
enabled and the WiBox does not
or WEP authentication type does
not match the AP.
Enable WEP encryption in WiBox.
Set encryption key and
authentication type to match the
AP. Ensure the key is entered in
HEX notation in both the AP and
the WiBox.
WiBox™ User Guide
82
Troubleshooting
Problem/Message
Reason
Cannot establish an Ad Hoc
network connection to the
WiBox.
Note: With 6.x.x.x firmware and
later, there is only one setting for
Network Name; it is the same for
both Infrastructure and Ad Hoc
modes.
Ad Hoc network is not enabled in Enable Ad Hoc network. Set Ad
the WiBox.
Hoc Network Name (IBSS) to
match. These are case-sensitive.
Cannot ping or connect to the
WiBox DHCP name.
Solution
Infrastructure Network Name
(SSID) is set blank or different
than the Ad Hoc name and the
WiBox is associated to
Infrastructure Network
Set the Infrastructure Network
Name (SSID) to the same name
as the Ad Hoc name.
The IP address is not set or not
in same subnet as other Ad Hoc
PCs or the WiBox.
Verify the IP address is set and in
the same subnet for each Ad Hoc
device.
The DHCP server is not
automatically setting the DHCP
name in DNS on the network.
Contact the Network
Administrator to add the WiBox to
DNS manually.
When you issue the ARP –S
Your user login does not have
command in Windows, The ARP the right to use this command on
entry addition failed: 5 message this PC.
displays.
Have your IT department log you
in with sufficient rights.
When you attempt to assign an
IP address to the unit by the
ARP method and Telnet to the
device server through port 1, the
connection fails.
Telnet back to Port 1. Wait for it to
fail, then Telnet to port 9999
again. Make sure you press Enter
within 5 seconds.
The ARP method only creates a
temporary password. When you
Telnet to port 1, the connection
should fail. When you Telnet into
port 9999 and do not press Enter
quickly, the device server
reboots, causing it to lose the IP
address.
When you Telnet to port 9999,
To enter Setup Mode via Telnet,
the Press Enter to go into Setup the Enter key must be pressed
Mode message displays.
within 5 seconds.
However, nothing happens when
you press Enter, or your
connection is closed.
Telnet to port 9999 again and
press Enter as soon as you see
the Press Enter to go into Setup
Mode message.
When you Telnet to port 1 to
You may have entered the
assign an IP address to the
Ethernet address incorrectly with
device server, the Telnet window the ARP command.
does not respond for a long time.
Confirm that the Ethernet address
that you entered with the ARP
command is correct. The Ethernet
address must only include
numbers 0-9 and letters A-F. In
Windows and usually in Unix, the
segments of the Ethernet address
are separated by dashes. In some
forms of Unix, the Ethernet
address is segmented with
colons.
WiBox™ User Guide
83
Troubleshooting
Problem/Message
Reason
Solution
The IP address you are trying to
assign is not on your logical
subnet.
Confirm that your PC has an IP
address and that it is in the same
logical subnet that you are trying
to assign to the device server.
The device server may not have
a network connection.
Note: Applies to WBX2100E
only.
Make sure that the Link LED is lit.
If the Link LED is not lit, then the
device server does not have a
network connection.
The device server is not
communicating with the serial
device it is attached to.
The most likely reason is the
wrong serial settings were
chosen.
The serial settings for the serial
device and the device server must
match. The default serial settings
for the device server are RS-232,
9600 baud, 8 character bits, no
parity, 1 stop bit, no flow control.
When you try to enter the setup
mode on the device server via
the serial port, you get no
response.
The issue is most likely
something covered in the
previous problem, or possibly,
you have Caps Lock on.
Double-check everything in the
problem above. Confirm that
Caps Lock is not on.
You can ping the device server,
but not Telnet to the device
server on port 9999.
There may be an IP address
conflict on your network
Turn the device server off and
then issue the following
commands at the DOS prompt of
your computer:
The Telnet configuration port
(9999) is disabled within the
device server security settings.
ARP -D X.X.X.X (X.X.X.X is the IP
of the device server).
PING X.X.X.X (X.X.X.X is the IP
of the device server).
If you get a response, then there
is a duplicate IP address on the
network. If you do not get a
response, use the serial port to
verify that Telnet is not disabled.
WiBox2100E only:
You are using the correct
serial cable, and the WiBox
should be set up correctly,
but you are not
communicating with your
device attached to the WiBox
across the network.
If you are sure that the serial
cable is correct, then you may
not be connecting to the
correct socket of the WiBox.
Another possibility is that the
WiBox is not set up correctly
to make a good socket
connection to the network.
You can check to see whether
there is a socket connection to
or from the WiBox by looking
at the Status LED.
If the Status LED is blinking
consistently, or is completely
off, then there is a good
socket connection.
If the Status LED is solid
green, then the socket
connection does not exist. Use
the Connect Mode option C0
for making a connection to the
WiBox™ User Guide
84
Troubleshooting
Problem/Message
Reason
Solution
WiBox from the network. Use
Connect Mode option C1 or
C5 for a connection to the
network from the WiBox
WiBox™ User Guide
85
Troubleshooting
Technical Support
If you are experiencing an error that is not described in this chapter, or if you are
unable to fix the error, you may:
To check our online knowledge base or send a question to Technical
Support, go to http://www.lantronix.com/support.
Email us at support@lantronix.com.
Call us at:
(800) 422-7044 Domestic
(949) 453-7198 International
(949) 450-7226 Fax
Our phone lines are open from 6:00AM - 5:00 PM Pacific Time Monday through
Friday excluding holidays.
Technical Support Europe, Middle East, and Africa
Phone: +49 (0) 89 31787 817
Email: eu_techsupp@lantronix.com or eu_support@lantronix.com
Firmware downloads, FAQs, and the most up-to-date documentation are available at:
www.lantronix.com/support
When you report a problem, please provide the following information:
Your name, and your company name, address, and phone number 
Lantronix model number
Lantronix MAC number
Software version (on the first screen shown when you Telnet to port 9999)
Description of the problem
Status of the unit when the problem occurred (please try to include
information on user and network activity at the time of the problem).
WiBox™ User Guide
86
A: Binary to Hexadecimal Conversions
Many of the unit’s configuration procedures require assembling a series of
options (represented as bits) into a complete command (represented as a byte).
Convert the resulting binary value to a hexadecimal representation.
Converting Binary to Hexadecimal
Following are two simple ways to convert binary numbers to hexadecimals.
Conversion Table
Hexadecimal digits have values ranging from 0 to F, which are represented as 09, A (for 10), B (for 11), etc. To convert a binary value (for example, 0100 1100)
to a hexadecimal representation, the upper and lower four bits are treated
separately, resulting in a two-digit hexadecimal number (in this case, 4C). Use
the following table to convert values from binary to hexadecimal.
Decimal
Binary
Hex
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
10
1010
11
1011
12
1100
13
1101
14
1110
15
1111
Scientific Calculator
Another simple way to convert binary to hexadecimals is to use a scientific
calculator, such as the one available on Windows’ operating systems. For
example:
1. On the Windows’ Start menu, click Programs Accessories Calculator.
2. On the View menu, select Scientific. The scientific calculator displays.
WiBox™ User Guide
87
Binary to Hexadecimal Conversions
3. Click Bin (Binary), and type the number to convert.
4. Click Hex. The hexadecimal value displays.
WiBox™ User Guide
88
Compliance
Compliance Information
Manufacturer’s Name & Address:
Lantronix 15353 Barranca Parkway, Irvine, CA 92618 USA
Declares that the following product:
Product Name Model: WiBoxE Device Server
Conforms to the following standards or other normative documents:
Safety:
UL 60950:2003
CAN/CSA-C22.2 No. 60950:2003
EN 60950:2003 +A1-A4, A11 , Low Voltage Directive (73/23/EEC)
EMC & Radio:
CFR Title 47 FCC Part 15, Subpart B and C, Class B
Industry Canada ICES-003 Issue 4 (2004), Class B
Industry Canada RSS-Gen Issue 1 (2005)
Industry Canada RSS-210 Issue 6 (2005)
EN 301 489-1 v1.4.1 (2002-08), EMC Directive (1999/5/EC)
EN 301 489-17 v.1.2.1 (2002-08), EMC Directive (1999/5/EC)
EN 300 328 v1.4.1 (2003-04), R&TTE Directive (1999/5/EC)
Australia / New Zealand AS/NZS CISPR 22 (2006), Class B
AS/NZS 4771 (2000 + A1:2003) (radio)
Japan VCCI (EMC emissions) V-3/2006-04
EN55022: 1998 + A1: 2000 + A2: 2003
EN55024: 1998 + A1: 2001 + A2: 2003
EN61000-3-2: 2000 + A2: 2005
EN61000-3-3: 1995 + A1: 2001
Manufacturer’s Contact:
Director of Quality Assurance, Lantronix
15353 Barranca Parkway, Irvine, CA 92618 USA
Tel: 949-453-3990
Fax: 949-453-3995
WiBox™ User Guide
89
Compliance
Regulatory Information
USA Federal Communications Commission (FCC) Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that
may cause undesired operation.
Caution: Changes or modifications to this product not expressly approved by
Lantronix could void the user's authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: Exposure to Radio Frequency Radiation
The equipment contains transmitter with FCC ID: R69WIPORTG (IC: 3867AWIPORTG).
The antenna(s) used for this transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or
transmitter. Installers and end-users must be provided with antenna
installation instructions and transmitter operating conditions for satisfying
RF exposure compliance.
Canada – Industry Canada Notice
This device complies with Industry Canada RSS-210 regulations. Operation is
subject to the following two conditions:
This device may not cause interference, and
This device must accept any interference, including interference that may
cause undesired operation of the device.
To prevent radio interference to the licensed service, this device must be
operated indoors only and should be kept away from windows to provide
maximum shielding.
WiBox™ User Guide
90
Compliance
This Class B digital apparatus complies with Canadian ICES-003.” Cet
appareil numérique de la classe B est conforme à la norme NMB- 003 du
Canada.
Antenna Notice:
This device has been designed to operate with an antenna having a maximum
gain of 3 dBi. Antenna having a higher gain is strictly prohibited per regulations of
Industry Canada. The required antenna impedance is 50 ohms.
To reduce potential radio interference to other users, the antenna type and its
gain should be so chosen that the equivalent isotropically radiated power (EIRP)
is not more than that required for successful communication.
Exposure of Humans to RF Fields
The installer of this radio equipment must ensure that the antenna is located or
pointed such that it does not emit RF field in excess of Health Canada limits for
the general population; consult Safety Code 6, obtainable from Health Canada’s
website: w w w . h c - s c . g c . c a / r p b
Europe – R&TTE Directive 99/5/EC, Wireless Notice
This product is designated as a Class 2 type radio device which utilizes nonharmonized frequencies and power levels for Europe. It is marked with the
following warning symbol to bring to your attention to the fact it might not be legal
to use this product in every country. In most cases this product has already been
granted permission for use from individual countries in Europe. If you are unsure,
please contact the communications authority for the country to be operated in.
In addition to this notice, the following countries in Europe have certain
restrictions on the operation of 2.4 GHz WLAN type devices:
Country
France
Italy
Luxembourg
Romania
Restriction
Outdoor use is limited to 10mW E.I.R.P within the frequency
band 2454-2483.5 MHz
If used outside of own premises, general authorization is
required
General authorization required for public service
Individual license is required.
Australia & New Zealand – Wireless Notice
This product has been found to be compliant with the wireless regulatory
requirements for Australia and New Zealand and is designated to have met
Compliance Level 2.
WiBox™ User Guide
91
Compliance
The compliance mark is designated with the circle and check mark inside is
called the “C-Tick” mark. This C-Tick mark label is located underneath this
product and signifies its compliance, as shown below:
The number “ ACN 095 223 484 “ stands for Australian Company Number and
the 9 digit number designates the local representative in Australia who can take
inquiries regarding this product’s compliance status. The following contact
address is found below:
Lantronix Australia Pty. Ltd.
c/o LLK Chartered Accountants
Suite 2, Level 7
122 Walker Street
North Sydney, NSW 2060
Australia
WiBox™ User Guide
92
Warranty
Lantronix warrants each Lantronix product to be free from defects in material and
workmanship for a period of TWO YEARS. During this period, if a customer is
unable to resolve a product problem with Lantronix Technical Support, a Return
Material Authorization (RMA) will be issued. Following receipt of a RMA number,
the customer shall return the product to Lantronix, freight prepaid. Upon
verification of warranty, Lantronix will -- at its option -- repair or replace the
product and return it to the customer freight prepaid. If the product is not under
warranty, the customer may have Lantronix repair the unit on a fee basis or
return it. No services are handled at the customer's site under this warranty. This
warranty is voided if the customer uses the product in an unauthorized or
improper way, or in an environment for which it was not designed.
Lantronix warrants the media containing its software product to be free from
defects and warrants that the software will operate substantially according to
Lantronix specifications for a period of 60 DAYS after the date of shipment. The
customer will ship defective media to Lantronix. Lantronix will ship the
replacement media to the customer.
In no event will Lantronix be responsible to the user in contract, in tort (including
negligence), strict liability or otherwise for any special, indirect, incidental or
consequential damage or loss of equipment, plant or power system, cost of
capital, loss of profits or revenues, cost of replacement power, additional
expenses in the use of existing software, hardware, equipment or facilities, or
claims against the user by its employees or customers resulting from the use of
the information, recommendations, descriptions and safety notations supplied by
Lantronix. Lantronix liability is limited (at its election) to:
Refund of buyer's purchase price for such affected products (without
interest).
Repair or replacement of such products, provided that the buyer follows
the above procedures.
There are no understandings, agreements, representations or warranties,
expressed or implied, including warranties of merchantability or fitness for a
particular purpose, other than those specifically set out above or by any existing
contract between the parties. Any such contract states the entire obligation of
Lantronix. The contents of this document shall not become part of or modify any
prior or existing agreement, commitment or relationship.
For details on the Lantronix warranty replacement policy, go to our web site at
www.lantronix.com/support/warranty
WiBox™ User Guide
93

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2006:06:15 11:04:41-07:00
Modify Date                     : 2006:06:15 11:04:41-07:00
Page Count                      : 93
Creation Date                   : 2006:06:15 18:04:41Z
Mod Date                        : 2006:06:15 18:04:41Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : jcandelas
Metadata Date                   : 2006:06:15 18:04:41Z
Creator                         : jcandelas
Title                           : Microsoft Word - WiBox User Guide 900-351f-WBX-UG_2.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R68WIPORTG

Navigation menu