PowerEdge-R6515-installation-technical-specifications, PowerEdge-R6515-AMD EPYC, PowerEdge-R6515-Dell-rack-server-rackmount, R6515-Non uniform memory access-AMD-NUMA, R6515-BIOS-UEFI-Trusted Platform Module, R6515-NVMe-SSD-IDSDM, R6515-PCIe-slot-cabling, R6515-expansion-card-riser, open-manage-enterprise-modular, iDRAC9-Quick-Sync-2

Dell EMC

Dell EMC PowerEdge R6515 Installation and Service Manual

The PowerEdge R6515 system is a 1U server that supports: ○ One AMD EPYC 7002 series processor. ○ 16 DIMM slots. ○ Two redundant AC power supply units.

Not Your Device? Search For Manuals / Datasheets:

File Info : application/pdf, 117 Pages, 3.48MB

Document
original
Dell EMC PowerEdge R6515
Installation and Service Manual
Regulatory Model: E45S Series Regulatory Type: E45S003 Dec 2020 Rev. A04

Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2019- 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.

Contents

Chapter 1: About this document.................................................................................................... 7
Chapter 2: PowerEdge R6515 system overview............................................................................. 8 Front view of the system...................................................................................................................................................8 Left control panel view................................................................................................................................................ 11 Right control panel view............................................................................................................................................. 12 Rear view of the system...................................................................................................................................................13 Inside the system .............................................................................................................................................................. 14 Locating the Express Service Code and Service Tag............................................................................................... 15 System information label..................................................................................................................................................15 Rail sizing and rack compatibility matrix.......................................................................................................................19
Chapter 3: Initial system setup and configuration........................................................................20 Setting up the system......................................................................................................................................................20 iDRAC configuration......................................................................................................................................................... 20 Options to set up iDRAC IP address.......................................................................................................................20 Options to log in to iDRAC.........................................................................................................................................21 Resources to install operating system......................................................................................................................... 22 Options to download firmware ................................................................................................................................22 Options to download and install OS drivers .........................................................................................................22 Downloading drivers and firmware..........................................................................................................................23
Chapter 4: Installing and removing system components.............................................................. 24 Safety instructions............................................................................................................................................................ 24 Before working inside your system............................................................................................................................... 25 After working inside your system.................................................................................................................................. 25 Recommended tools......................................................................................................................................................... 25 Optional front bezel.......................................................................................................................................................... 26 Removing the front bezel..........................................................................................................................................26 Installing the front bezel............................................................................................................................................ 26 System cover......................................................................................................................................................................27 Removing the system cover..................................................................................................................................... 27 Installing the system cover....................................................................................................................................... 28 Drive backplane cover......................................................................................................................................................29 Removing the drive backplane cover..................................................................................................................... 29 Installing the drive backplane cover........................................................................................................................30 Air shroud............................................................................................................................................................................ 32 Removing the air shroud............................................................................................................................................32 Installing the air shroud.............................................................................................................................................. 32 Cooling fan.......................................................................................................................................................................... 33 Removing a cooling fan.............................................................................................................................................. 33 Installing a cooling fan................................................................................................................................................ 34 Intrusion switch module...................................................................................................................................................35 Removing the intrusion switch.................................................................................................................................35

Contents

3

Installing the intrusion switch...................................................................................................................................36 Drives....................................................................................................................................................................................37
Removing a drive blank.............................................................................................................................................. 37 Installing a drive blank................................................................................................................................................ 38 Removing the drive carrier........................................................................................................................................38 Installing the drive carrier..........................................................................................................................................39 Removing the drive from the drive carrier............................................................................................................40 Installing the drive into the drive carrier.................................................................................................................41 Drive backplane..................................................................................................................................................................42 Drive backplane............................................................................................................................................................42 Removing the backplane .......................................................................................................................................... 43 Installing the drive backplane................................................................................................................................... 44 Cable routing...................................................................................................................................................................... 46 System memory................................................................................................................................................................. 47 System memory guidelines........................................................................................................................................ 47 General memory module installation guidelines....................................................................................................49 Removing a memory module..................................................................................................................................... 51 Installing a memory module.......................................................................................................................................52 Processor and heat sink.................................................................................................................................................. 53 Removing a heat sink................................................................................................................................................. 53 Removing the AMD processor................................................................................................................................. 54 Installing the AMD processor................................................................................................................................... 56 Installing the heat sink................................................................................................................................................58 Expansion cards and expansion card risers................................................................................................................ 60 Expansion card installation guidelines.................................................................................................................... 60 Removing the expansion card risers....................................................................................................................... 62 Installing the expansion card risers......................................................................................................................... 63 Removing expansion card from the expansion card riser..................................................................................65 Installing an expansion card into the expansion card riser................................................................................ 67 Micro SD card.................................................................................................................................................................... 70 Removing the MicroSD card.....................................................................................................................................70 Installing the MicroSD card....................................................................................................................................... 70 M.2 SSD module................................................................................................................................................................. 71 Removing the M.2 SSD module................................................................................................................................ 71 Installing the M.2 SSD module..................................................................................................................................72 Optional IDSDM module................................................................................................................................................... 73 Removing the IDSDM module...................................................................................................................................73 Installing the IDSDM module..................................................................................................................................... 74 LOM riser card................................................................................................................................................................... 75 Removing the LOM riser card.................................................................................................................................. 75 Installing the LOM riser card.....................................................................................................................................77 Mini PERC card..................................................................................................................................................................79 Removing the mini PERC card................................................................................................................................. 79 Installing the mini PERC card................................................................................................................................... 80 System battery ................................................................................................................................................................. 82 Replacing the system battery...................................................................................................................................82 Optional internal USB memory key............................................................................................................................... 83 Replacing optional internal USB memory key....................................................................................................... 83 VGA module........................................................................................................................................................................ 85 Removing the VGA module....................................................................................................................................... 85

4

Contents

Installing the VGA module......................................................................................................................................... 85 Optional optical drive........................................................................................................................................................86
Removing the optical drive....................................................................................................................................... 86 Installing the optical drive..........................................................................................................................................87 Power supply unit..............................................................................................................................................................88 Hot spare feature........................................................................................................................................................ 88 Removing a power supply unit blank...................................................................................................................... 89 Installing a power supply unit blank.........................................................................................................................89 Removing a power supply unit................................................................................................................................. 90 Installing a power supply unit.................................................................................................................................... 91 Power interposer board................................................................................................................................................... 92 Removing the power interposer board...................................................................................................................92 Installing the power interposer board.....................................................................................................................92 System board..................................................................................................................................................................... 93 Removing the system board..................................................................................................................................... 93 Installing the system board....................................................................................................................................... 94 Trusted Platform Module................................................................................................................................................ 97 Upgrading the Trusted Platform Module...............................................................................................................97 Control panel...................................................................................................................................................................... 98 Removing the left control panel.............................................................................................................................. 98 Installing the left control panel.................................................................................................................................99 Removing the right control panel.......................................................................................................................... 100 Installing the right control panel............................................................................................................................. 101
Chapter 5: Jumpers and connectors...........................................................................................103 System board connectors..............................................................................................................................................104 System board jumper settings......................................................................................................................................105 Disabling a forgotten password................................................................................................................................... 105
Chapter 6: System diagnostics and indicator codes................................................................... 106 Status LED indicators..................................................................................................................................................... 106 System health and system ID indicator codes.......................................................................................................... 107 iDRAC Quick Sync 2 indicator codes.......................................................................................................................... 107 iDRAC Direct LED indicator codes.............................................................................................................................. 108 LCD panel.......................................................................................................................................................................... 108 Viewing Home screen............................................................................................................................................... 109 Setup menu................................................................................................................................................................. 109 View menu....................................................................................................................................................................110 NIC indicator codes..........................................................................................................................................................110 Power supply unit indicator codes................................................................................................................................ 111 Drive indicator codes....................................................................................................................................................... 112 Using system diagnostics............................................................................................................................................... 112 Dell Embedded System Diagnostics....................................................................................................................... 113
Chapter 7: Getting help.............................................................................................................. 114 Recycling or End-of-Life service information............................................................................................................114 Contacting Dell..................................................................................................................................................................114 Accessing system information by using QRL.............................................................................................................114 Quick Resource Locator for PowerEdge R6515 system................................................................................... 115

Contents

5

Receiving automated support with SupportAssist ..................................................................................................115 Chapter 8: Documentation resources..........................................................................................116

6

Contents

1
About this document
This document provides an overview about the system, information about installing and replacing components, technical specifications, diagnostic tools, and guidelines to be followed while installing certain components.

About this document

7

2
PowerEdge R6515 system overview
The PowerEdge R6515 system is a 1U server that supports:  One AMD EPYC 7002 series processor  16 DIMM slots  Two redundant AC power supply units  Up to 4 x 3.5-inch, 8 x 2.5-inch SAS/SATA drives, 10 x 2.5-inch drives (with 8 SAS/SATA/ NVMe drives + 2 NVMe drives)
or 10x 2.5-inch NVMe drives only. NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support> Browse all Products > Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Documentation > Manuals and Documents.
NOTE: All instances of SAS, SATA drives are referred to as drives in this document, unless specified otherwise.
For more information about supported drives, see the Dell EMC PowerEdge R6515 Technical Specifications.
Topics:
· Front view of the system · Rear view of the system · Inside the system · Locating the Express Service Code and Service Tag · System information label · Rail sizing and rack compatibility matrix
Front view of the system

Figure 1. Front view of 4 x 3.5-inch drive system

Table 1. Features available on the front of the system

Item

Ports, panels, and slots

Icon

Description

1

Left control panel

N/A

Contains the system health, system ID, status LED, and the iDRAC Quick Sync 2 (wireless) indicator.

NOTE: The iDRAC Quick Sync 2 indicator is available only on certain configurations.

 Status LED: Enables you to identify any failed hardware components. There are up to five status LEDs and an overall

8

PowerEdge R6515 system overview

Table 1. Features available on the front of the system (continued)

Item

Ports, panels, and slots

Icon

Description

system health LED (Chassis health and system ID) bar. For more information, see the Status LED indicators section.
 Quick Sync 2 (wireless): Indicates a Quick Sync enabled system. The Quick Sync feature is optional. This feature allows management of the system by using mobile devices called as OpenManage Mobile (OMM) feature. Using iDRAC Quick Sync 2 with OpenManage Mobile (OMM) aggregates hardware or firmware inventory and various system level diagnostic and error information that can be used in troubleshooting the system. For more information, see the iDRAC User's Guide available at https://www.dell.com/ idracmanuals

2

Optical drive (optional) N/A

3

VGA port

4

Right control panel

N/A

5

Information tag

One optional slim SATA DVD-ROM drive or DVD+/-RW drive.
Enables you to connect a display device to the system. For more information, see the Dell EMC PowerEdge R6515 Technical Specifications.
Contains the power button, USB port, iDRAC Direct micro port, and the iDRAC Direct status LED.
The Information tag is a slide-out label panel that contains system information such as Service Tag, NIC, MAC address, and so on. If you have opted for the secure default access to iDRAC, the Information tag also contains the iDRAC secure default password.

6

Drive (4)

N/A

Enables you to install drives that are supported on your system. For more information about drives, see the Dell EMC PowerEdge R6515 Technical Specifications.

Figure 2. Front view of 8 x 2.5-inch drive system

Table 2. Features available on the front of the system

Item

Ports, panels, and slots

Icon

Description

1

Left control panel

N/A

Contains the system health, system ID, status LED, and the iDRAC Quick Sync 2 (wireless) indicator.

NOTE: The iDRAC Quick Sync 2 indicator is available only on certain configurations.

 Status LED: Enables you to identify any failed hardware components. There are up to five status LEDs and an overall system health LED (Chassis health and system ID) bar. For more information, see the Status LED indicators section.
 Quick Sync 2 (wireless): Indicates a Quick Sync enabled system. The Quick Sync feature is optional. This feature allows management of the system by using mobile devices

PowerEdge R6515 system overview

9

Table 2. Features available on the front of the system (continued)

Item

Ports, panels, and slots

Icon

Description

called as OpenManage Mobile (OMM) feature. Using iDRAC Quick Sync 2 with OpenManage Mobile (OMM) aggregates hardware or firmware inventory and various system level diagnostic and error information that can be used in troubleshooting the system. For more information, see the iDRAC User's Guide available at https://www.dell.com/ idracmanuals

2

Optical drive (optional) N/A

3

VGA port

4

Right control panel

N/A

5

Information tag

One optional slim SATA DVD-ROM drive or DVD+/-RW drive.
Enables you to connect a display device to the system. For more information, see the Dell EMC PowerEdge R6515 Technical Specifications.
Contains the power button, USB port, iDRAC Direct micro port, and the iDRAC Direct status LED.
The Information tag is a slide-out label panel that contains system information such as Service Tag, NIC, MAC address, and so on. If you have opted for the secure default access to iDRAC, the Information tag also contains the iDRAC secure default password.

6

Drive (8)

N/A

Enables you to install drives that are supported on your system. For more information about drives, see the Dell EMC PowerEdge R6515 Technical Specifications.

Figure 3. Front view of 10 x 2.5-inch drive system

Table 3. Features available on the front of the system

Item

Ports, panels, and slots

Icon

Description

1

Left control panel

N/A

Contains the system health, system ID, status LED, and the iDRAC Quick Sync 2 (wireless) indicator.

NOTE: The iDRAC Quick Sync 2 indicator is available only on certain configurations.

 Status LED: Enables you to identify any failed hardware components. There are up to five status LEDs and an overall system health LED (Chassis health and system ID) bar. For more information, see the Status LED indicators section.
 Quick Sync 2 (wireless): Indicates a Quick Sync enabled system. The Quick Sync feature is optional. This feature allows management of the system by using mobile devices called as OpenManage Mobile (OMM) feature. Using iDRAC Quick Sync 2 with OpenManage Mobile (OMM) aggregates hardware or firmware inventory and various system level diagnostic and error information that can be used in

10

PowerEdge R6515 system overview

Table 3. Features available on the front of the system (continued)

Item

Ports, panels, and slots

Icon

Description

troubleshooting the system. For more information, see the iDRAC User's Guide available at https://www.dell.com/ idracmanuals

2

VGA port

3

Right control panel

N/A

4

Information tag

Enables you to connect a display device to the system. For more information, see the Dell EMC PowerEdge R6515 Technical Specifications.
Contains the power button, USB port, iDRAC Direct micro port, and the iDRAC Direct status LED.
The Information tag is a slide-out label panel that contains system information such as Service Tag, NIC, MAC address, and so on. If you have opted for the secure default access to iDRAC, the Information tag also contains the iDRAC secure default password.

5

Drive (10)

N/A

Enables you to install drives that are supported on your system. For more information about drives, see the Dell EMC PowerEdge R6515 Technical Specifications.

For more information about the ports, see the Dell EMC PowerEdge R6515 Technical Specifications.

Left control panel view

Figure 4. Left control panel without optional iDRAC Quick Sync 2.0 indicator

Figure 5. Left control panel with optional iDRAC Quick Sync 2.0 indicator

Table 4. Left control panel

Item Indicator, button, or connector

1

Status LED indicators

Icon Description
N/A Indicates the status of the system. For more information, see the Status LED indicators section.

PowerEdge R6515 system overview

11

Table 4. Left control panel (continued)

Item Indicator, button, or connector

Icon Description

2

System health and system ID

indicator

Indicates the system health. For more information, see the System health and system ID indicator codes section.

3

iDRAC Quick Sync 2 wireless

indicator (optional)

Indicates if the iDRAC Quick Sync 2 wireless option is activated. The Quick Sync 2 feature allows management of the system using mobile devices. This feature aggregates hardware/firmware inventory and various system level diagnostic/error information that can be used in troubleshooting the system. You can access system inventory, Dell Lifecycle Controller logs or system logs, system health status, and also configure iDRAC, BIOS, and networking parameters. You can also launch the virtual Keyboard, Video, and Mouse (KVM) viewer and virtual Kernel-based Virtual Machine (KVM), on a supported mobile device. For more information, see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals

NOTE: For more information about the indicator codes, see the System diagnostics and indicator codes section.

Right control panel view

Figure 6. Right control panel

Table 5. Right control panel

Item Indicator or button

1

Power button

Icon

2

USB 2.0-compliant port

3

iDRAC Direct LED

N/A

indicator

4

iDRAC Direct port (Micro-

AB USB)

Description
Indicates if the system is powered on or off. Press the power button to manually power on or off the system.
NOTE: Press the power button to gracefully shut down an ACPIcompliant operating system.
The USB port is a 4-pin connector and 2.0-compliant. This port enables you to connect USB devices to the system.
The iDRAC Direct LED indicator lights up to indicate that the iDRAC Direct port is actively connected to a device.
The iDRAC Direct port (Micro-AB USB) enables you to access the iDRAC direct Micro-AB USB features. For more information, see the https:// www.dell.com/idracmanuals.
NOTE: You can configure iDRAC Direct by using a USB to micro USB (type AB) cable, which you can connect to your laptop or tablet. Cable

12

PowerEdge R6515 system overview

Table 5. Right control panel (continued)

Item Indicator or button

Icon

Description
length should not exceed 3 feet (0.91 meters). Performance could be affected by cable quality.

NOTE: For more information on the ports, see the Dell EMC PowerEdge R6515 Technical Specifications.

Rear view of the system

Figure 7. Rear view of the system

Table 6. Rear view of the system

Item

Ports, panels, or slots Icon

1

Serial port

2

iDRAC dedicated port

3

Ethernet ports (2)

4

PCIe expansion card riser N/A

1A (slot 2)

5

PCIe expansion card riser N/A

2 (slot 3)

6

Power supply unit (PSU 1) N/A

7

Power supply unit (PSU N/A

2)

8

LOM Riser Ethernet port N/A

(2) (Optional)

9

USB 3.0 port (2)

10

VGA port

11

System status indicator N/A

cable port

12

System identification

button

Description Enables you to connect a serial device to the system.
Enables you to remotely access iDRAC. For more information, see the iDRAC User's Guide at www.dell.com/poweredgemanuals.
The Ethernet ports that are integrated on the system board provide network connectivity. These NIC ports can also be shared with iDRAC when iDRAC network settings is set to shared mode.
The expansion card riser enables you to connect PCI Express expansion cards.
The expansion card riser enables you to connect PCI Express expansion cards. For more information on the expansion cards that are supported on your system, see the Dell EMC PowerEdge R6515 Technical Specifications.
For information about the PSU configurations, see the Dell EMC PowerEdge R6515 Technical Specifications.
For information about the PSU configurations, see the Dell EMC PowerEdge R6515 Technical Specifications.
The NIC ports that are integrated on the LAN on Motherboard (LOM) riser provide network connectivity. These USB ports support USB 3.0.
Enables you to connect a display device to the system.
Enables you to connect the status indicator cable and view system status when the CMA is installed. Press the system ID button:  To locate a particular system within a rack.  To turn the system ID on or off.

PowerEdge R6515 system overview

13

Table 6. Rear view of the system (continued)

Item

Ports, panels, or slots Icon

Description
To reset iDRAC, press and hold the button for 16 seconds. NOTE:
 To reset iDRAC using system ID, ensure that the system ID button is enabled in the iDRAC setup.
 If the system stops responding during POST, press and hold the system ID button (for more than five seconds) to enter the BIOS progress mode.

For more information about the ports and connectors, see the Dell EMC PowerEdge R6515 Technical Specifications.

Inside the system

Figure 8. Inside the system
1. Riser 1A 3. System board 5. Memory module slots 7. Information tag 9. Backplane 11. Intrusion switch 13. Air shroud

14

PowerEdge R6515 system overview

2. Mini PERC card 4. Heat sink 6. Fan 8. Backplane cover 10. Cable retention latch 12. Power interposer board 14. Riser 2

15. PSU 1 and PSU 2
Locating the Express Service Code and Service Tag
The unique Express Service Code and Service Tag are used to identify the system. The information tag is located on the front of the system that includes system information such as Service Tag, Express Service Code, Manufacture date, NIC, MAC address, QRL label, and so on. If you have opted for the secure default access to iDRAC, the Information tag also contains the iDRAC secure default password. If you have opted for iDRAC Quick Sync 2, the Information tag also contains the OpenManage Mobile (OMM) label, where administrators can configure, monitor, and troubleshoot the PowerEdge servers.
Figure 9. Locating the Express Service Code and Service tag 1. Information tag (front view) 2. Information tag (back view) 3. OpenManage Mobile (OMM) label 4. iDRAC MAC address and iDRAC secure password label 5. Service Tag, Express Service Code, QRL label The Mini Enterprise Service Tag (MEST) label is located on the rear of the system that includes Service Tag (ST), Express Service Code (Exp Svc Code), and Manufacture Date (Mfg. Date). The Exp Svc Code is used by Dell EMC to route support calls to the appropriate personnel. Alternatively, the Service Tag information is located on a label on left wall of the chassis.
System information label
The system information label is located on back side of the system cover.

PowerEdge R6515 system overview

15

Figure 10. Service information

16

PowerEdge R6515 system overview

Figure 11. Memory information

PowerEdge R6515 system overview

17

Figure 12. System tasks

Figure 13. Icon Legend

18

PowerEdge R6515 system overview

Figure 14. R6515 QRL
Rail sizing and rack compatibility matrix
For specific information about the rail solutions compatible with your system, see the Dell EMC Enterprise Systems Rail Sizing and Rack Compatibility Matrix available at https://i.dell.com/sites/csdocuments/Business_solutions_engineeringDocs_Documents/en/rail-rack-matrix.pdf. The document provides the information that is listed below:  Specific details about rail types and their functionalities  Rail adjustability ranges for various rack mounting flange types  Rail depth with and without cable management accessories  Rack types that are supported for various rack mounting flange types

PowerEdge R6515 system overview

19

3

Initial system setup and configuration

This section describes the tasks for initial setup and configuration of the Dell EMC system. The sections provide general steps that you must complete to set up the system and the reference guides for detailed information.
Topics:
· Setting up the system · iDRAC configuration · Resources to install operating system

Setting up the system
Perform the following steps to set up the system:
Steps 1. Unpack the system. 2. Install the system into the rack. For more information see the rail installation and cable management accessory guides
relevant to your rail and cable management solution at www.dell.com/poweredgemanuals. 3. Connect the peripherals to the system and the system to the electrical outlet. 4. Power on the system by pressing the power button.
For more information about setting up the system, see the Getting Started Guide that is shipped with your system.

iDRAC configuration

The Integrated Dell Remote Access Controller (iDRAC) is designed to make you more productive as a system administrator and improve the overall availability of Dell EMC servers. iDRAC alerts you to system issues, helps you to perform remote management, and reduces the need for physical access to the system.

Options to set up iDRAC IP address

To enable communication between your system and iDRAC, you must first configure the network settings based on your network infrastructure. The network settings option is set to DHCP, by default.
NOTE: For static IP configuration, you must request for the setting at the time of purchase.

You can set up the iDRAC IP address using one of the following interfaces. For information about how to set up iDRAC IP address, see the documentation links provided in the table.

Table 7. Interfaces to set up iDRAC IP address Interface iDRAC Settings utility

Documentation links
Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals or for system specific Integrated Dell Remote Access Controller User's Guide, go to https://www.dell.com/poweredgemanuals > Product Support page of your system > Manuals & documents.
NOTE: To determine the most recent iDRAC release for your platform and for latest documentation version, see KB article https://www.dell.com/support/article/ sln308699.

20

Initial system setup and configuration

Table 7. Interfaces to set up iDRAC IP address (continued)

Interface

Documentation links

OpenManage Deployment Toolkit

OpenManage Deployment Toolkit User's Guide available at https://www.dell.com/openmanagemanuals > Open Manage Deployment Toolkit.

Lifecycle Controller
Server LCD panel iDRAC Direct and Quick Sync 2 (optional)

Lifecycle Controller User's Guide at https://www.dell.com/ idracmanuals or for system specific Lifecycle Controller User's Guide, go to https://www.dell.com/poweredgemanuals > Product Support page of your system > Manuals & documents.
NOTE: To determine the most recent iDRAC release for your platform and for latest documentation version, see KB article https://www.dell.com/support/article/ sln308699.
LCD panel section.
Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals or for system specific Integrated Dell Remote Access Controller User's Guide, go to https://www.dell.com/poweredgemanuals > Product Support page of your system > Manuals & documents.
NOTE: To determine the most recent iDRAC release for your platform and for latest documentation version, see KB article https://www.dell.com/support/article/ sln308699.

NOTE: To access iDRAC, ensure that you connect the ethernet cable to the iDRAC9 dedicated network port or use iDRAC Direct port by using the USB cable. You can also access iDRAC through the shared LOM mode, if you have opted for a system that has the shared LOM mode enabled.

Options to log in to iDRAC
To log in into the iDRAC Web User Interface, open a browser and enter the IP address. You can log in to iDRAC as:  iDRAC user  Microsoft Active Directory user  Lightweight Directory Access Protocol (LDAP) user In the login screen displayed, if you have opted for secure default access to iDRAC, enter the iDRAC secure default password available on back side of the Information Tag. If you have not opted for secure default access to iDRAC, enter the default user name and password ­ root and calvin. You can also log in by using your Single Sign-On or Smart Card.
NOTE: Ensure that you change the default username and password after setting up the iDRAC IP address.
For more information about logging in to the iDRAC and iDRAC licenses, see the latest Integrated Dell Remote Access Controller User's Guide at www.dell.com/idracmanuals.
NOTE: To determine the most recent iDRAC release for your platform and for latest documentation version, see KB article https://www.dell.com/support/article/sln308699.
You can also access iDRAC using command-line protocol - RACADM. For more information, see the iDRAC with Lifecycle Controller RACADM CLI Guide available at www.dell.com/idracmanuals. You can also access iDRAC using automation tool - Redfish API. For more information, see the iDRAC9 with Lifecycle Controller Redfish API Guide available at https://www.dell.com/idracmanuals.

Initial system setup and configuration

21

Resources to install operating system

If the system is shipped without an operating system, you can install a supported operating system by using one of the resources provided in the table. For information about how to install the operating system, see the documentation links provided in the table.

Table 8. Resources to install the operating system

Resource

Documentation links

iDRAC

Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals or for system specific Integrated Dell Remote Access Controller User's Guide, go to https://www.dell.com/ poweredgemanuals > Product Support page of your system > Manuals & documents.
NOTE: To determine the most recent iDRAC release for your platform and for latest
documentation version, see KB article at https://www.dell.com/support/article/sln308699.

Lifecycle Controller

Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals or for system specific Lifecycle Controller User's Guide, go to https://www.dell.com/poweredgemanuals > Product Support page of your system > Manuals & documents. Dell recommends installing Lifecycle Controller to install the OS, since all required drivers are installed to the system.
NOTE: To determine the most recent iDRAC release for your platform and for latest
documentation version, see KB article at https://www.dell.com/support/article/sln308699.

OpenManage Deployment Toolkit

www.dell.com/openmanagemanuals > OpenManage Deployment Toolkit

Dell certified VMware www.dell.com/virtualizationsolutions ESXi

NOTE: For more information about Installation and How-to videos for supported operating systems on PowerEdge system see, Supported Operating Systems for Dell EMC PowerEdge systems.

Options to download firmware

You can download firmware from Dell support site. For information, see the Downloading drivers and firmware section.
You can also choose any one of the following options to download the firmware. For information about how to download the firmware, see the documentation links provided in the table.

Table 9. Options to download firmware
Option
Using Dell Remote Access Controller Lifecycle Controller (iDRAC with LC)

Documentation link www.dell.com/idracmanuals

Using Dell Repository Manager (DRM) Using Dell Server Update Utility (SUU)

www.dell.com/openmanagemanuals > Repository Manager www.dell.com/openmanagemanuals > Server Update Utility

Using Dell OpenManage Deployment Toolkit (DTK) Using iDRAC virtual media

www.dell.com/openmanagemanuals > OpenManage Deployment Toolkit
www.dell.com/idracmanuals

Options to download and install OS drivers
You can choose any one of the following options to download and install OS drivers. For information about how to download or install OS drivers, see the documentation links provided in the table.

22

Initial system setup and configuration

Table 10. Options to download and install OS drivers

Option

Documentation

Dell EMC support site

Downloading drivers and firmware section.

iDRAC virtual media

Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals or for system specific Integrated Dell Remote Access Controller User's Guide, go to https://www.dell.com/poweredgemanuals > Product Support page of your system > Manuals & documents.
NOTE: To determine the most recent iDRAC release for
your platform and for latest documentation version, see
https://www.dell.com/support/article/sln308699.

Downloading drivers and firmware
It is recommended that you download and install the latest BIOS, drivers, and systems management firmware on the system.
Prerequisites Ensure that you clear the web browser cache before downloading the drivers and firmware.
Steps 1. Go to www.dell.com/support/drivers. 2. Enter the Service Tag of the system in the Enter a Dell Service Tag, Dell EMC Product ID or Model field, and then press
Enter. NOTE: If you do not have the Service Tag, select Detect PC to automatically detect the Service Tag, or click Browse all products, and navigate to your product.
3. On the displayed product page, click Drivers & Downloads. On the Drivers & Downloads page, all drivers that are applicable to the system are displayed.
4. Download the drivers to a USB drive, CD, or DVD.

Initial system setup and configuration

23

4
Installing and removing system components
Topics:
· Safety instructions · Before working inside your system · After working inside your system · Recommended tools · Optional front bezel · System cover · Drive backplane cover · Air shroud · Cooling fan · Intrusion switch module · Drives · Drive backplane · Cable routing · System memory · Processor and heat sink · Expansion cards and expansion card risers · Micro SD card · M.2 SSD module · Optional IDSDM module · LOM riser card · Mini PERC card · System battery · Optional internal USB memory key · VGA module · Optional optical drive · Power supply unit · Power interposer board · System board · Trusted Platform Module · Control panel
Safety instructions
NOTE: To avoid injury, do not lift the system on your own. Get others to assist you.
WARNING: Opening or removing the system cover while the system is turned on may expose you to a risk of electric shock.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
CAUTION: To ensure proper operation and cooling, all system bays and fans must be always populated with a component or a blank.

24

Installing and removing system components

NOTE: It is recommended that you always use an antistatic mat and antistatic strap while working on components inside the system.
NOTE: While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals
NOTE: While replacing faulty storage controller/FC/NIC card with the same type of card, after you power on the system; the new card automatically updates to the same firmware and configuration of the faulty one. For more information about the Part replacement configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals
Before working inside your system
Prerequisites Follow the safety guidelines listed in Safety instructions on page 24.
Steps 1. Power off the system and all attached peripherals. 2. Disconnect the system from the electrical outlet, and disconnect the peripherals. 3. If applicable, remove the system from the rack.
For more information, see the Rail Installation Guide relevant to your rail solutions at www.dell.com/poweredgemanuals. 4. Remove the system cover.
After working inside your system
Prerequisites Follow the safety guidelines listed in Safety instructions on page 24.
Steps 1. Replace the system cover. 2. If applicable, install the system into the rack.
For more information, see the Rail Installation Guide relevant to your rail solutions at www.dell.com/poweredgemanuals. 3. Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.
Recommended tools
You need the following tools to perform the removal and installation procedures:  Key to the bezel lock. The key is required only if your system includes a bezel.  Phillips #1 screwdriver  Phillips #2 screwdriver  Torx #T20 screwdriver  5mm hex nut screwdriver  Plastic scribe  1/4 inch flat blade screwdriver  Wrist grounding strap connected to the ground  ESD mat

Installing and removing system components

25

Optional front bezel
NOTE: LCD panel is optional on the front bezel. If the front bezel has an LCD panel, see LCD panel section.
Removing the front bezel
The procedure to remove the front bezel with and without the LCD panel is the same.
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Keep the bezel key handy.
NOTE: The bezel key is part of the LCD bezel package.
Steps 1. Unlock the bezel. 2. Press the release button, and disengage the left end of the bezel. 3. Unhook the right end, and remove the bezel.

Figure 15. Removing the front bezel with the LCD panel
Next steps Replace the bezel.
Installing the front bezel
The procedure to install the front bezel with and without the LCD panel is the same. Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Locate and remove the bezel key.
NOTE: The bezel key is part of the LCD bezel package.

26

Installing and removing system components

Steps
1. Align and insert the tabs on the bezel into the slots on the system. 2. Press the bezel until the release button clicks in place. 3. Lock the bezel.

Figure 16. Installing the front bezel with the LCD panel
System cover
Removing the system cover
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Power off the system, and any attached peripherals. 3. Disconnect the system from the electrical outlet and peripherals.
Steps 1. Use a 1/4 inch flat head or a Phillips #2 screwdriver to rotate the lock counterclockwise to the unlock position. 2. Lift the release latch until the system cover slides back. 3. Lift the cover from the system.

Installing and removing system components

27

Figure 17. Removing the system cover
Next steps Replace the system cover.
Installing the system cover
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in Before working inside your system on page 25. 3. Ensure that all internal cables are connected and routed properly, and no tools or extra parts are left inside the system.
Steps 1. Align the tabs on the system cover with the guide slots on the system. 2. Close the system cover release latch. 3. Using a 1/4 inch flat head or Phillips #2 screwdriver, rotate the lock clockwise to the lock position.

28

Installing and removing system components

Figure 18. Installing the system cover
Next steps Follow the procedure listed in After working inside your system on page 25.
Drive backplane cover
Removing the drive backplane cover
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. Steps 1. Slide the backplane cover in the direction of the arrows marked on the backplane cover. 2. Lift the backplane cover from the system.

Installing and removing system components

29

Figure 19. Removing the drive backplane cover
Next steps Replace the backplane cover.
Installing the drive backplane cover
Prerequisites Follow the safety guidelines listed in the Safety instructions on page 24. Steps 1. Align the backplane cover with the guide slots on the system. 2. Slide the backplane cover toward the front of the system until the backplane cover fits into place.

30

Installing and removing system components

Figure 20. Installing the drive backplane cover
Next steps Follow the procedure listed in After working inside your system on page 25.

Installing and removing system components

31

Air shroud
Removing the air shroud
Prerequisites CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in shutdown of the system and loss of data.
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25.
Steps Hold the air shroud touch points at both ends and lift the air shroud out of the system.

Figure 21. Removing the air shroud
Next steps Replace the air shroud.
Installing the air shroud
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25.
Steps 1. Align the slot on the air shroud with the standoff on the chassis. 2. Lower the air shroud into the system until it is firmly seated.

32

Installing and removing system components

Figure 22. Installing the air shroud
Next steps Follow the procedure listed in After working inside your system on page 25.
Cooling fan
Removing a cooling fan
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Move the cables out of way to access the fan cable connector on the system board.
NOTE: Observe the fan cable routing or make a note on the fan cable routing.
Steps 1. Disconnect the cooling fan cable connected to the system board connector. 2. Holding the blue tab, lift the cooling fan out of the fan cage.

Installing and removing system components

33

Figure 23. Removing a cooling fan
Next steps Replace a fan.
Installing a cooling fan
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25.
Steps 1. Lower the cooling fan into the cage until it is seated firmly. 2. Route the cable properly to prevent the cable from being pinched or crimped. 3. Press the release tabs on the fan cable connector and connect the cable to the system board.

34

Installing and removing system components

Figure 24. Installing a cooling fan
Next steps 1. Install the air shroud. 2. Follow the procedure listed in After working inside your system on page 25.
Intrusion switch module
Removing the intrusion switch
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Keep the plastic scribe ready.
Steps 1. Disconnect and remove the intrusion switch cable from the connector on the system board.
Observe the routing of the cable as you remove it from the system. 2. Using a plastic scribe, slide the intrusion switch out of the intrusion switch slot.

Installing and removing system components

35

Figure 25. Removing the intrusion switch
Next steps Replace the intrusion switch.
Installing the intrusion switch
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. Steps 1. Align and slide the intrusion switch in the slot until it is firmly seated in the slot on the system.
NOTE: Route the cable properly when you replace it to prevent the cable from being pinched or crimped. 2. Connect the intrusion switch cable to the connector on the system board.

36

Installing and removing system components

Figure 26. Installing the intrusion switch
Next steps 1. Install the air shroud. 2. Follow the procedure listed in After working inside your system on page 25.
Drives
Removing a drive blank
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. If installed, remove the front bezel.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
Steps Press the release button, and slide the drive blank out of the drive slot.

Figure 27. Removing a drive blank

Installing and removing system components

37

Next steps Installing a drive or replace the drive blank.
Installing a drive blank
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. If installed, remove the front bezel.
Steps Insert the drive blank into the drive slot until the release button clicks into place.

Figure 28. Installing a drive blank
Next steps If removed, install the front bezel.
Removing the drive carrier
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. If installed, remove the front bezel. 3. Using the management software, prepare the drive for removal.
If the drive is online, the green activity or fault indicator blinks while the drive is powering off. When the drive indicators are off, the drive is ready for removal. For more information, see the documentation for the storage controller.
CAUTION: Before attempting to remove or install a drive while the system is running, see the documentation for the storage controller card to ensure that the host adapter is configured correctly to support drive removal and insertion. CAUTION: To prevent data loss, ensure that your operating system supports drive installation. See the documentation supplied with your operating system.
Steps 1. Press the release button to open the drive carrier release handle. 2. Holding the drive carrier release handle, slide the drive carrier out of the drive slot.

38

Installing and removing system components

Figure 29. Removing a drive carrier
Next steps Install a drive carrier or drive blank.
Installing the drive carrier
Prerequisites CAUTION: Before removing or installing a drive while the system is running, see the documentation for the storage controller card to ensure that the host adapter is configured correctly to support drive removal and insertion.
CAUTION: Combining SAS and SATA drives in the same RAID volume is not supported.
CAUTION: When installing a drive, ensure that the adjacent drives are fully installed. Inserting a drive carrier and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier's shield spring and make it unusable. CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation supplied with your operating system. CAUTION: When a replacement hot swappable drive is installed and the system is powered on, the drive automatically begins to rebuild. Ensure that the replacement drive is blank or contains data that you wish to overwrite. Any data on the replacement drive is immediately lost after the drive is installed.
NOTE: Ensure that the drive carrier's release handle is in the open position before inserting the carrier into the slot. 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. If installed, remove the front bezel. 3. Remove the drive carrier or remove the drive blank when you want to assemble the drives in to the system.
Steps 1. Slide the drive carrier into the drive slot. 2. Close the drive carrier release handle to lock the drive in place.

Installing and removing system components

39

Figure 30. Installing a drive carrier
Next steps If removed, install the front bezel.
Removing the drive from the drive carrier
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. If installed, remove the front bezel.
Steps 1. Using a Phillips #1 screwdriver, remove the screws from the slide rails on the drive carrier.
NOTE: If the hard drive or SSD carrier has Torx screw, use Torx 6 (for 2.5-inch drive) or Torx 8 (for 3.5-inch drive) screwdriver to remove the drive. 2. Lift the drive out of the drive carrier.

40

Installing and removing system components

Figure 31. Removing the drive from the drive carrier
Next steps Install the drive into the drive carrier.
Installing the drive into the drive carrier
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. If installed, remove the front bezel. 3. Remove the drive blank.
NOTE: When installing a drive into the drive carrier, ensure that the screws are torqued to 4 in-lbs.
Steps 1. Insert the drive into the drive carrier with the drive connector facing towards the rear of the carrier. 2. Align the screw holes on the drive with the screws holes on the drive carrier. 3. Using a Phillips #1 screwdriver, secure the drive to the drive carrier with the screws.
NOTE: If the hard drive or SSD carrier has Torx screw, use Torx 6 (for 2.5-inch drive) or Torx 8 (for 3.5-inch drive) screwdriver to install the drive.
NOTE: When installing a drive into the drive carrier, ensure that the screws are torqued to 4 in-pounds.

Installing and removing system components

41

Figure 32. Installing a drive into the drive carrier

Next steps 1. Install the drive carrier. 2. If removed, install the front bezel.
Drive backplane

Drive backplane

Depending on your system configuration, the drive backplanes supported are listed here:

Table 11. Supported backplane options System
PowerEdge R6515

Supported hard drives options 3.5 inch (x4) SAS, SATA backplane 2.5 inch (x8) SAS or SATA backplane 2.5 inch (x10) SAS, SATA or NVMe backplane

Figure 33. 4 x 3.5-drive backplane
1. release tab 2. SAS_A connector on the backplane 3. backplane power cable

42

Installing and removing system components

Figure 34. 8 x 2.5-drive backplane
1. release tab 3. backplane signal cable 5. SATA_B cable connector

2. SATA_A cable connector 4. backplane 6. backplane power cable

Figure 35. 10 x 2.5-SAS, SATA or NVMe drive backplane
1. B0 NVMe cable connector 3. A0 NVMe cable connector 5. B1 NVMe cable connector 7. SAS/SATA cable connector 9. backplane power connector

2. I2C cable connector 4. SAS/SATA cable connector 6. A1 NVMe cable connector 8. A2 NVMe cable connector

Removing the backplane
Prerequisites CAUTION: To prevent damage to the drives and backplane, remove the drives from the system before removing the backplane.
CAUTION: Note the number of each drive and temporarily label them before you remove the drive so that you can reinstall them in the same location.
NOTE: The procedure to remove the backplane is similar for all backplane configurations.
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Remove the backplane cover. 5. Remove all the drives. 6. Disconnect the VGA cable from the system board.
NOTE: Observe the routing of the cable as you remove it from the system. 7. If installed, disconnect the optical drive signal and power cables from the drive.
Steps 1. Press the blue release tabs to disengage the drive backplane from the hooks on the system. 2. Lift the drive backplane out of the system.
NOTE: To avoid damaging the backplane, ensure that you move the control panel cables from the cable routing clips before removing the backplane.

Installing and removing system components

43

Figure 36. Removing the backplane
Next steps Replace the drive backplane.
Installing the drive backplane
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Remove the backplane cover. 5. Remove all the drives.
NOTE: To avoid damaging the backplane, ensure to move the control panel cables from the cable routing clips before removing the backplane. NOTE: Route the cable properly when you replace it to prevent the cable from being pinched or crimped.
Steps 1. Use the hooks on the system as guides to align the slots on the backplane with the guides on the system. 2. Insert the backplane into the guides and lower the backplane until the blue release tabs click into place.

44

Installing and removing system components

Figure 37. Installing the drive backplane
Next steps 1. Reconnect the VGA cable to the system board. 2. If disconnected, reconnect the optical drive power and signal cables to the drive. 3. Reconnect all the disconnected cables to the backplane. 4. Install all the drives. 5. Install the backplane cover. 6. Install the air shroud. 7. Follow the procedure listed in After working inside your system on page 25.

Installing and removing system components

45

Cable routing

Figure 38. Cable routing - 4 x 3.5-inch drive backplane to the mini-PERC card

Figure 39. Cable routing - 4 x 3.5-inch drive backplane to the onboard controller

46

Installing and removing system components

Figure 40. Cable routing - 8 x 2.5-inch drive backplane to the mini-PERC card

Figure 41. Cable routing - 10 x 2.5-inch drive backplane to the onboard controller (NVMe)
System memory
System memory guidelines
The PowerEdge R6515 system supports DDR4 registered DIMMs (RDIMMs) and load reduced DIMMs (LRDIMMs). System memory holds the instructions that are executed by the processor.

Installing and removing system components

47

Your system memory is organized into eight channels per processor (two memory sockets per channel) for a total of 16 memory sockets per processor. In each channel, the 1st socket is marked white and the 2nd socket black.

Figure 42. Memory socket location

Memory channels are organized as follows:

Table 12. Memory channels

Processo Channel A Channel

r

B

AMD

Slots 6 and Slots 5

Processor 12

and 11

Channel C Channel D Channel E

Slots 2 and Slots 1 and Slots 8 and

10

9

16

Channel F Channel G

Channel H

Slots 7 and Slots 4 and 14 Slots 3 and 13 15

Table 13. Supported memory matrix

DIMM type

Rank type

Capacity

DIMM rated voltage and Operating Speed speed

1 DIMMs per Channel (DPC)

RDIMM

1R

8 GB

DDR4 (1.2V), 3200 MT/s 3200 MT/s

2R

16 GB, 32 GB, 64 DDR4 (1.2V), 3200 MT/s 3200 MT/s

GB

LRDIMM

8R

128 GB

DDR4 (1.2V), 2666 MT/s 2666 MT/s

2 DIMMs per Channel (DPC) 2933 MT/s 2933 MT/s
2666 MT/s

48

Installing and removing system components

General memory module installation guidelines

To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory. If your system's memory configurations fail to observe these guidelines, your system might not boot, stop responding during memory configuration, or operate with reduced memory. This section provides information on the memory population rules and about the non-uniform memory access (NUMA) for single or dual processor system.
The memory bus may operate at speeds of 3200 MT/s, 2933 MT/s, or 2666 MT/s depending on the following factors:
 System profile selected (for example, Performance Optimized, or Custom [can be run at high speed or lower])  Maximum supported DIMM speed of the processors  Maximum supported speed of the DIMMs

NOTE: MT/s indicates DIMM speed in MegaTransfers per second.

The system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset architectural configuration. The following are the recommended guidelines for installing memory modules:
 All DIMMs must be DDR4.  Mixing of memory module capacities in a system is not supported.  If memory modules with different speeds are installed, they operate at the speed of the slowest installed memory module(s).  Populate memory module sockets only if a processor is installed.
 For single-processor systems, sockets A1 to A16 are available.  In Optimizer Mode, the DRAM controllers operate independently in the 64-bit mode and provide optimized memory
performance.

Table 14. Memory population rules

Processor

Configuration

Memory population

Memory population information

Single processor

Optimizer (Independent channel) population order

A{1}, A{2}, A{3}, A{4}, A{5}, A{6}, A{7}, A{8}, A{9}, A{10}, A{11}, A{12}, A{13}, A{14}, A{15}, A{16}

Odd amount of DIMMs per processor allowed.

 Populate all the sockets with white release tabs first, followed by the black release tabs.  Unbalanced or odd memory configuration results in a performance loss and system may not identify the memory modules
being installed, so always populate memory channels identically with equal DIMMs for best performance.
 Minimum recommended configuration is to populate four equal memory modules per processor. AMD recommends limiting processors in that system to 32 cores or less.
 Populate eight equal memory modules per processor (one DIMM per channel) at a time to maximize performance. NOTE: Equal memory modules refer to DIMMs with identical electrical specification and capacity that may be from
different vendors.

Memory interleaving with Non-uniform memory access (NUMA)

Non-uniform memory access (NUMA) is a memory design used in multi-processing, where the memory access time depends on the memory location relative to the processor. In NUMA, a processor can access its own local memory faster than the non-local memory.

NUMA nodes per socket (NPS) is a new feature added that allows you to configure the memory NUMA domains per socket. The configuration can consist of one whole domain (NPS1), two domains (NPS2), or four domains (NPS4). In the case of a twosocket platform, an additional NPS profile is available to have whole system memory to be mapped as single NUMA domain (NPS0). For more information on the memory interleaving for NPSx, see the Memory interleaving population rules section in this topic.

BIOS implementation for NPSx

 The BIOS Setup menu presents the applicable NPSx options based on the underlying model number. A change to the current NPSx is communicated to pre-BIOS firmware to take effect on the next boot. The default NPS setting is 1.
 During boot, if the selected NPSx option is not allowed for the model number (for example, if the processor model number changes between reboot), system will halt at the end of POST with UEFI0388 message displayed. On the next reboot, the system will fall back to NPS1 default setting.
 During boot, if the preferred interleaving for the current NPSx is not possible due to memory configuration (for example, the memory population is inconsistent with the preferred interleaving), BIOS shows a warning message UEFI0391.

Installing and removing system components

49

NOTE: System is functional when UEFI0391 message is displayed. However, the system may not be configured for optimal performance.
NPS system optimization
Optimal system configuration is dependent on the processor model, memory configuration, and NPS settings. Match the memory configuration with the NPS settings available for the processor.

Table 15. Supported NPS modes by Processors Model Number 7742

NPS modes supported 4, 2, 1, 0

7702 7702P

4, 2, 1, 0 4, 2, 1

7662 7642

4, 2, 1, 0 4, 2, 1, 0

7552 7542

2, 1, 0 4, 2, 1, 0

7532 7502

4, 2, 1, 0 4, 2, 1, 0

7502P

4, 2, 1

7452 7402

4, 2, 1, 0 4, 2, 1, 0

7402P 7352

4, 2, 1 4, 2, 1, 0

7302 7302P

4, 2, 1, 0 4, 2, 1

7282

1, 0

7272

1, 0

7262

4, 2, 1, 0

7252

1, 0

7232P

1

7F72 7F52

2, 1, 0 4, 2, 1, 0

7F32 7H12

4, 2, 1, 0 4, 2, 1, 0

Table 16. Optimal NPS configuration

Number of

NPS

DIMMs per

processor

0

1

2

4

1

X

2

X

3

X

4

X

50

Installing and removing system components

Table 16. Optimal NPS configuration (continued)

Number of

NPS

DIMMs per

processor

0

1

2

4

5

X

6

X

7

X

8

X

X

9

X

10

X

11

X

12

X

13

X

14

X

15

X

16

X

X

 Recommended NPS setting is marked by X that indicate optimal performance.  NPS0 is only available for dual processor systems and is the preferred setting.  The NPS setting that are blank are functional. However, indicate non-optimal performance.  BIOS default NPS setting is 1.  UEFI0391 message may be displayed during boot if DIMMs are configured in the blank spaces of the table.  If the processor does not support the desired NPS setting for a given number of DIMMs, then use default setting (NPS1)
and the UEFI0391 message is displayed.
Memory interleaving population rules
 NPS4: Two channel interleaving
 This interleaves channel [A and B], [C and D], etc.  Each channel within the pair requires at least one equal memory modules populated.  Works with three memory modules per channel pair, non-symmetrical module is stacked on top (odd configurations).  Any memory channel where one of the two channels is not populated is not interleaved.  There is no alternate, as all configurations can be mapped into this mode.  NPS2: Four channel interleaving
 This interleaves the four channels on the left or right half of a processor which are channels [A, B, C, D] and [E, F, G, H].  All four channels require equal memory modules populated.  Each half or interleave set may have different total memory capacity with respect to each other.  NPS1: Eight channel interleaving
 This interleaves all channels in a processor [A, B, C, D, E, F, G, H].  All channels in a processor require equal memory modules populated.  Single processor system creates a single NUMA node for the system.
NOTE: An exception is allowed when system has 4-channels populated [C, D, G, H] with equal memory allowing the
system to enter NPS1 mode even though all the 8 channels are not populated.

Removing a memory module

Prerequisites
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud.

Installing and removing system components

51

WARNING: The memory modules are hot to touch for some time after the system has been powered off. Allow the memory modules to cool before handling them.
Steps 1. Locate the appropriate memory module socket. 2. To release the memory module from the socket, simultaneously press the ejectors on both ends of the memory module
socket to fully open. CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the memory module or metallic contacts.
3. Lift the memory module away from the system.

Figure 43. Removing a memory module
Next steps Replace the memory module.
Installing a memory module
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud.
Steps 1. Locate the appropriate memory module socket.
CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the memory module or metallic contacts. 2. If a memory module is installed in the socket, remove it. NOTE: Ensure the socket ejector latches are fully open, before installing the memory module.
3. Align the edge connector of the memory module with the alignment key of the memory module socket, and insert the memory module in the socket. CAUTION: To prevent damage to the memory module or the memory module socket during installation, do not bend or flex the memory module; insert both ends of the memory module simultaneously.

52

Installing and removing system components

NOTE: The memory module socket has an alignment key that enables you to install the memory module in the socket in only one orientation.
CAUTION: Do not apply pressure at the center of the memory module; apply pressure at both ends of the memory module evenly.
4. Press the memory module with your thumbs until the ejectors firmly click into place. When the memory module is properly seated in the socket, the levers on the memory module socket align with the levers on the other sockets that have memory modules installed.

Figure 44. Installing a memory module

Next steps 1. Install the air shroud. 2. Follow the procedure listed in After working inside your system on page 25. 3. To verify if the memory module has been installed properly, press F2 and navigate to System Setup Main Menu > System
BIOS > Memory Settings. In the Memory Settings screen, the System Memory Size must reflect the updated capacity of the installed memory. 4. If the System Memory Size is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory modules are firmly seated in their sockets. 5. Run the system memory test in system diagnostics.
Processor and heat sink
Removing a heat sink
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud.
NOTE: The heat sink and processor are too hot to touch for some time after the system has been powered down. Allow the heat sink and processor to cool down before handling them.
Steps 1. Using a Torx #T20 screwdriver, loosen the captive screws in the order mentioned on the heat sink:

Installing and removing system components

53

NOTE: The captive screw numbers are marked on the heat sink.
a. Partially loosen the captive screws 1 and 2 (approximately 3 turns). b. Partially loosen the captive screws 3 and 4 (approximately 3 turns). c. Loosen the captive screws 1 and 2 completely. d. Loosen the captive screws 3 and 4 completely. 2. Lift the heat sink from the system.

Figure 45. Removing a heat sink
Next steps If you are removing a faulty heat sink, replace the heat sink, if not, remove the processor.
Removing the AMD processor
Prerequisites WARNING: The heat sink may be hot to touch for some time after the system has been powered off. Allow the heat sink to cool before removing it.
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Remove the heat sink.
CAUTION: You may find the CMOS battery loss or CMOS checksum error displayed during the first instance of powering on the system after the processor or system board replacement which is expected. To fix this, simply go to setup option to configure the system settings.
Steps 1. Using a Torx #T20 screwdriver, loosen the screws to release the force plate. The sequence to loosen the screws is 3, 2, and
1.

54

Installing and removing system components

Figure 46. Removing screws on the force plate 2. Release the processor socket rail frame by lifting up the blue latches.

Figure 47. Lifting the rail frame 3. Holding the blue tab on the processor tray, slide the tray out of the rail frame.

Installing and removing system components

55

Figure 48. Removing the processor tray
Next steps Replace the AMD processor.
Installing the AMD processor
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in Before working inside your system on page 25. Steps 1. Holding the blue tab on the processor tray, slide the tray into the processor socket rail frame until firmly seated.

56

Installing and removing system components

Figure 49. Placing the processor tray into the rail frame 2. Push the rail frame down until the blue latches lock into place.

Figure 50. Closing the rail frame
3. Secure the force plate to the processor socket base by tightening the screws in the sequence 1, 2, and 3. When all three screws are fully threaded, the socket is then actuated. The three screws are tightened to a torque value of 12.0 ± 1.0 lbf-in. NOTE: Press the force plate while tightening the screws to avoid tilting of the processor cover out of the processor socket.

Installing and removing system components

57

Figure 51. Securing the force plate
Next steps 1. Install the heat sink. 2. Install the air shroud. 3. Follow the procedure listed in After working inside your system on page 25.
Installing the heat sink
Prerequisites Never remove the heat sink from a processor unless you intend to replace the processor or system board. The heat sink is necessary to maintain proper thermal conditions. 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. If installed, remove the processor dust cover.
Steps 1. If you are using an existing heat sink, remove the thermal grease on the heat sink by using a clean lint-free cloth.
NOTE: For a new heat sink, the thermal paste is pre-applied to the heat sink. Remove the protective cover and install the heat sink.
2. Use the thermal grease syringe included with your processor kit to apply the grease in a thin spiral on the top of the processor.

58

Installing and removing system components

Figure 52. Installing the heat sink
CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and contaminating the processor socket.
NOTE: The thermal grease syringe is intended for single use only. Dispose of the syringe after you use it.
3. Align the heat sink with the screw holes on the processor plate. The captive screws on the heat sink should align with the screw holes on the processor plate.
4. Using a Torx #T20 screwdriver, tighten the captive screws in the order mentioned below: NOTE: The captive screw numbers are marked on the heat sink.
a. Partially tighten the captive screws 1 and 2 (approximately 3 turns). b. Partially tighten the captive screws 3 and 4 (approximately 3 turns). c. Tighten the captive screws 1 and 2 completely. d. Tighten the captive screws 3 and 4 completely.

Figure 53. Installing the heat sink
Next steps 1. Install the air shroud.

Installing and removing system components

59

2. Follow the procedure listed in the After working inside your system on page 25.

Expansion cards and expansion card risers

NOTE: A system event entry is logged in the iDRAC Lifecycle Controller if an expansion card riser is not supported or missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message, see Troubleshooting expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/ poweredgemanuals.

Expansion card installation guidelines

The following table describes the supported expansion cards:

Table 17. Expansion card riser configurations

Expansion card riser

PCIe slots on the Processor

riser

connection

No riser

Slot 1

Processor 1

Riser 1A

Slot 2

Processor 1

Riser 2

Slot 3

Processor 1

Height NA Low Profile Low Profile

Length NA Half Length Half Length

Slot width x8 x16 x16

NOTE: The expansion-card slots are not hot-swappable.

The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card priority and slot priority order.

Table 18. No riser configuration (Slot 1)

Card type

Slot priority

PERC 9: Mini mono (H730P/H330)

Integrated slot

PERC 10: Mini mono (H740P)

Integrated slot

HBA: Mini mono (HBA330)

Integrated slot

LOM riser ( 2x1 G)/(2x10 G)/(2x25 G) 1

Maximum number of cards 1 1 1 1

Table 19. Riser configuration (include slots 1 and 3)

Card type

Slot priority

PERC 9: Mini mono (H730P/H330)

Integrated slot

PERC 10: Mini mono (H740P)

Integrated slot

HBA: Mini mono (HBA330)

Integrated slot

PERC 10: External adapter (H840)

3

HBA: External adapter

3

NVME PCIE SSD

3

Broadcom (1 G QP)

3

Broadcom (10 G DP)

3

Broadcom (25 G DP)

3

Intel 10 G (BaseT DP)

3

Maximum number of cards 1 1 1 1 1 1 1 1 1 1

60

Installing and removing system components

Table 19. Riser configuration (include slots 1 and 3) (continued)

Card type

Slot priority

Intel 10 G (SFP+ DP)

3

Intel 1 G (QP)

3

Intel 25 G (SFP DP)

3

Emulex (FC32 2P/1P)

3

Emulex (FC16 1P)/(FC16 2P)

3

Mellanox 100 G (CX5/CX6 H100)

3

Mellanox 25 G (CX4LX DP/CX5 DP)

3

Qlogic (HBA FC32 SP/DP)

3

Qlogic (HBA FC16 SP/DP)

3

Qlogic 10 G (SFP DP)

3

Qlogic 25 G ( BaseT DP)

3

Internal storage (BOSS)

3

Nvidia T4 GPGPU

3

Solarflare 25 G (SFP DP)

3

LOM Riser ( 2x1 G)/(2x10 G)/(2x25 G) 1

Table 20. Riser configuration (include slots 1, 2, and 3)

Card type

Slot priority

PERC 9: Mini mono (H730P/H330)

Integrated slot

PERC 10: Mini mono (H740P)

Integrated slot

HBA: Mini mono (HBA330)

Integrated slot

PERC 10: External adapter (H840)

3, 2

HBA: External adapter

3, 2

NVME PCIE SSD

3, 2

Broadcom (1 G DP/1G QP)

3, 2

Broadcom (10 G DP)

3, 2

Broadcom (25 G DP)

3, 2

Intel 10 G (BaseT DP)

3, 2

Intel 10 G (SFP+ DP)

3, 2

Intel 1 G (QP)

3, 2

Intel 25 G (SFP DP)

3, 2

Emulex (FC32 2P/1P)

3, 2

Emulex (FC16 1P)/(FC16 2P)

3, 2

Mellanox 100 G (CX5/CX6 H100)

3, 2

Mellanox 25 G (CX4LX DP/CX5 DP)

3, 2

Qlogic (HBA FC32 SP/DP)

3, 2

Qlogic (HBA FC16 SP/DP)

3, 2

Qlogic 10 G (SFP DP)

3, 2

Maximum number of cards 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Maximum number of cards 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

Installing and removing system components

61

Table 20. Riser configuration (include slots 1, 2, and 3) (continued)

Card type

Slot priority

Qlogic 25 G ( BaseT DP)

3, 2

Internal Storage (BOSS)

3, 2

Nvidia T4 GPGPU

3

Solarflare 25 G (SFP DP)

3, 2

LOM riser ( 2x1 G)/(2x10 G)/(2x25 G) 1

Maximum number of cards 2 1 1 2 1

Removing the expansion card risers
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Disconnect any cables connected to the expansion card.
Steps Hold the touch points, and lift the expansion card riser from the riser connector on the system board.

Figure 54. Removing the low profile left riser
NOTE: For low profile riser right, first loosen the captive screw and then holding the touch points lift the riser away from the system. NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

62

Installing and removing system components

Figure 55. Removing the low profile right riser
Next steps Replace the expansion card riser.
Installing the expansion card risers
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. If removed, install the expansion cards into the expansion card risers.
Steps 1. Holding the touch points, align the expansion card riser with the connector and the riser guide pin on the system board. 2. Lower the expansion card riser into place until the expansion card riser connector is fully seated in the connector.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

Installing and removing system components

63

Figure 56. Installing the low profile left riser NOTE: For low profile riser right, tighten the captive screw to secure the riser to the system board.

Figure 57. Installing the low profile right riser
Next steps 1. If required, re-connect the cables to the expansion card. 2. Install the air shroud. 3. Follow the procedure listed in After working inside your system on page 25. 4. Install any device drivers required for the card as described in the documentation for the card.

64

Installing and removing system components

Removing expansion card from the expansion card riser
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. If applicable, disconnect the cables from the expansion card.
NOTE: The procedure to remove the T4 GPU card and the expansion card is the same.
Steps 1. Pull and lift up the expansion card retention latch lock to open. 2. Hold the expansion card by its edges and pull the card until the card edge connector disengages from the expansion card
connector on the riser. NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

Figure 58. Removing an expansion card from the low profile left riser

Installing and removing system components

65

Figure 59. Removing an expansion card from the low profile right riser
3. If the expansion card is not going to be replaced, install a filler bracket and close the card retention latch. NOTE: You must install a filler bracket over an empty expansion card slot to maintain Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.

Figure 60. Installing filler bracket in the low profile left riser

66

Installing and removing system components

Figure 61. Installing filler bracket in the low profile right riser
Next steps If applicable, install an expansion card into the expansion card riser.
Installing an expansion card into the expansion card riser
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. If installing a new expansion card, unpack it and prepare the card for installation.
NOTE: For instructions, see the documentation accompanying the card.
NOTE: The procedure to install the T4 GPU card and the expansion card is the same.
Steps 1. Pull and lift up the expansion card retention latch lock to open. 2. If installed, remove the filler bracket.
NOTE: Store the filler bracket for future use. Filler brackets must be installed in empty expansion card slots to maintain Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system. NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

Installing and removing system components

67

Figure 62. Removing a filler bracket from a low profile left riser

Figure 63. Removing a filler bracket from a low profile right riser
3. Hold the card by the edges, and align the card edge connector with the expansion card connector on the riser. 4. Insert the card edge connector firmly into the expansion card connector until the card is fully seated. 5. Close the expansion card retention latch.

68

Installing and removing system components

Figure 64. Installing an expansion card into a low profile left riser

Figure 65. Installing an expansion card into a low profile right riser
Next steps 1. If applicable, connect the cables to the expansion card. 2. Install the air shroud. 3. Follow the procedure listed in After working inside your system on page 25. 4. Install any device drivers required for the card as described in the documentation for the card.
NOTE: While replacing faulty storage controller/FC/NIC card with the same type of card, after you power on the system; the new card automatically updates to the same firmware and configuration of the faulty one. For more information about the Part replacement configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals

Installing and removing system components

69

Micro SD card
Removing the MicroSD card
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Remove the IDSDM module.
Steps 1. Locate the MicroSD card slot on the IDSDM module, and press the card to partially release it from the slot. For more
information on the slot location, see System board jumpers and connectors section. 2. Hold the MicroSD card and remove it from the slot..
NOTE: Temporarily label each MicroSD card with its corresponding slot number after removal.

Figure 66. Removing the MicroSD card
Next steps Install the MicroSD cards.
Installing the MicroSD card
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in Before working inside your system on page 25. 3. Remove the air shroud.
NOTE: To use an MicroSD card with your system, ensure that the Internal SD Card Port is enabled in System Setup. NOTE: Ensure that you install the MicroSD cards into the same slots based on the labels you had marked on the cards during removal.

70

Installing and removing system components

Steps 1. Locate the MicroSD card slot on the IDSDM module. Orient the MicroSD card appropriately and insert the contact-pin end
of the card into the slot. To locate IDSDM, see the System board jumpers and connectors section. NOTE: The slot is keyed to ensure correct insertion of the card.
2. Press the card into the slot to lock it into place.

Figure 67. Installing the MicroSD card
Next steps 1. Install the IDSDM module. 2. Install the air shroud. 3. Follow the procedure listed in the After working inside your system on page 25.
M.2 SSD module
Removing the M.2 SSD module
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Remove the BOSS card.
NOTE: The procedure to remove the BOSS card is similar to removing an expansion card.
Steps 1. Using the Phillips #1 screwdriver, remove the screws securing the M.2 SSD module to the BOSS card. 2. Pull the M.2 SSD module to disconnect from the connector on the BOSS card.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

Installing and removing system components

71

Figure 68. Removing the M.2 SSD module
Next steps Replace the M.2 SSD module.
Installing the M.2 SSD module
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Remove the BOSS card.
NOTE: The procedure to remove the BOSS card is similar to the removing an expansion card.
Steps 1. Align the M.2 SSD module at an angle with the connector on the BOSS card. 2. Insert the M.2 SSD module until it is firmly seated in the BOSS card connector. 3. Using the Phillips #1 screwdriver, secure the M.2 SSD module on the BOSS card with the screw.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

72

Installing and removing system components

Figure 69. Installing the M.2 SSD module
Next steps 1. Install the BOSS card.
NOTE: The procedure to install the BOSS card is similar to removing an expansion card. 2. Install the air shroud. 3. Follow the procedure listed in the After working inside your system on page 25.
Optional IDSDM module
Removing the IDSDM module
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. If you are replacing the IDSDM card, remove the MicroSD cards.
NOTE: Temporarily label each SD card with its corresponding slot number before removal. Reinstall the SD cards into the corresponding slots.
Steps Holding the pull tab, lift the IDSDM card out of the system.

Installing and removing system components

73

Figure 70. Removing the IDSDM module
Next steps Replace the IDSDM module.
Installing the IDSDM module
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud.
Steps 1. Locate the IDSDM connector on the system board.
To locate IDSDM, see the System board jumpers and connectors section. 2. Align IDSDM module with the connector on the system board. 3. Push IDSDM module until it is firmly seated in the connector on the system board.

74

Installing and removing system components

Figure 71. Installing the IDSDM module
Next steps 1. Install the MicroSD cards.
NOTE: Reinstall the MicroSD cards into the same slots based on the labels you had marked on the cards during removal. 2. Install the air shroud. 3. Follow the procedure listed in the After working inside your system on page 25.
LOM riser card
Removing the LOM riser card
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. If installed, remove the risers.
Steps 1. Using a Phillips #2 screwdriver, remove the screws that secure the LAN on Motherboard (LOM) riser card to the system
board. 2. Push apart the two blue plastic clips securing the LOM riser card to release the riser. 3. Holding the LOM riser card by the edges, lift to disconnect the card from the connector on the system board. 4. Slide the LOM riser card towards the front of the system until the Ethernet connectors or the SFP+ are clear of the slot in
the back panel.

Installing and removing system components

75

Figure 72. Removing the LOM riser card
5. Lift the LOM riser card out of the system. 6. Remove the LOM bracket.
a. Using the Phillips #2 screwdriver, remove the screw that secures the bracket to the chassis. b. Slide the bracket out of the slot on the chassis.

Figure 73. Removing the LOM riser bracket
7. If the LOM riser is not being replaced immediately, install the LOM filler bracket. a. Insert and slide the filler into the slot on the chassis. b. Using the Phillips #2 screwdriver, secure the filler bracket to the chassis with a screw.

76

Installing and removing system components

Figure 74. Installing the LOM filler bracket
Next steps Replace the LOM riser card.
Installing the LOM riser card
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. If installed, remove the risers.
Steps 1. Remove the LOM filler bracket.
a. Using the Phillips #2 screwdriver, remove the screw that secures the bracket to the system. b. Slide the bracket out of the slot on the system.

Installing and removing system components

77

Figure 75. Removing the LOM filler bracket
2. Install the LOM bracket. a. Insert and slide the LOM bracket into the slot on the system. b. Using the Phillips #2 screwdriver, secure the bracket to the system with a screw

Figure 76. Installing the LOM riser bracket
3. Orient the LOM riser card to fit the Ethernet connectors or the SFP+ through the slot of the bracket. 4. Press the LOM riser card until the card is firmly seated on the system board connector and the two blue plastic clips to
secure the LOM riser card in place. 5. Using a Phillips #2 screwdriver, secure the LOM riser card to the system board with screws.

78

Installing and removing system components

Figure 77. Installing the LOM riser card
Next steps 1. If removed, install the risers. 2. Install the air shroud. 3. Follow the procedure listed in After working inside your system on page 25.
NOTE: While replacing faulty storage controller/FC/NIC card with the same type of card, after you power on the system; the new card automatically updates to the same firmware and configuration of the faulty one. For more information about the Part replacement configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals
Mini PERC card
Removing the mini PERC card
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. If installed, remove the risers..
Steps 1. Using a Phillips #2 screwdriver, loosen the screws that secure the cable to the mini PERC card. 2. Holding the tab, lift the cable to disconnect from the mini PERC card.

Installing and removing system components

79

Figure 78. Removing the mini PERC card cable
3. Slide out the mini PERC card to disengage from the card holder on the system board. 4. Lift the mini PERC card out of the system.

Figure 79. Removing the mini PERC card

Next steps Replace the mini PERC card.
Installing the mini PERC card
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in Before working inside your system on page 25.

80

Installing and removing system components

Steps 1. Angle the mini PERC card to engage with the mini PERC card holder on the system board. 2. Lower the mini PERC card into place until the mini PERC card is firmly seated on the card holder.

Figure 80. Installing the mini PERC card
3. Align the screws on the cable with the screw holes on the mini PERC card. 4. Using a Phillips #2 screwdriver, secure the cable to the mini PERC card with the screws.

Figure 81. Installing the mini PERC card cable
Next steps 1. If removed, install the expansion card risers. 2. Install the air shroud. 3. Follow the procedure listed in the After working inside your system on page 25.

Installing and removing system components

81

NOTE: While replacing faulty storage controller/FC/NIC card with the same type of card, after you power on the system; the new card automatically updates to the same firmware and configuration of the faulty one. For more information about the Part replacement configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals
System battery
Replacing the system battery
Prerequisites WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions. See the Safety instructions. that came with your system for more information..
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. If applicable, disconnect the power or data cables from the expansion card(s). 4. Remove the LOM riser card.
Steps 1. To remove the battery:
a. Use a plastic scribe to pry out the system battery.

Figure 82. Removing the system battery
CAUTION: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.
2. To install a new system battery: To install a new system battery, a. Hold the battery with the positive side facing up and slide it under the securing tabs. b. Press the battery into the connector until it snaps into place.

82

Installing and removing system components

Figure 83. Installing the system battery

Next steps 1. Install the LOM riser card. 2. If applicable, connect the cables to the expansion card(s). 3. Follow the procedure listed in the After working inside your system on page 25. 4. Confirm that the battery is operating properly, by performing the following steps:
a. Enter the System Setup, while booting, by pressing F2. b. Enter the correct time and date in the System Setup Time and Date fields. c. Exit the System Setup. d. To test the newly installed battery, remove the system from the enclosure for at least an hour. e. Reinstall the system into the enclosure after an hour. f. Enter the System Setup and if the time and date are still incorrect, see Getting help section.
Optional internal USB memory key
NOTE: To locate the internal USB port on the system board, see the System board jumpers and connectors section.
Replacing optional internal USB memory key
Prerequisites CAUTION: To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud.
Steps 1. Locate the USB port or USB memory key on the system board.
To locate the internal USB port on the system board, see the System board jumpers and connectors section. 2. If installed, remove the USB memory key from the USB port.

Installing and removing system components

83

Figure 84. Removing the USB memory key 3. Insert the replacement USB memory key into the USB port.

Figure 85. Installing the USB memory key
Next steps 1. Install the air shroud. 2. Follow the procedure listed in After working inside your system on page 25. 3. While booting, press F2 to enter System Setup and verify that the system detects the USB memory key.

84

Installing and removing system components

VGA module
Removing the VGA module
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the front bezel. 4. Remove the backplane cover. 5. Remove the air shroud. 6. Disconnect the VGA cable from the VGA connector on the system board. For locating the connector, see the System board
jumpers and connecters section. NOTE: Ensure that you note the routing of the cables as you remove them from the system board. Route the cable properly when you replace it to prevent the cable from being pinched or crimped
Steps 1. Using Phillips #1 screwdriver, remove the screw on the VGA module. 2. Slide the module out of the system.

Figure 86. Removing the VGA module

Next steps Install the VGA module.
Installing the VGA module
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the front bezel. 4. Remove the backplane cover. 5. Remove the air shroud.
NOTE: Ensure that you note the routing of the cables as you remove them from the system board. Route the cable properly when you replace it to prevent the cable from being pinched or crimped

Installing and removing system components

85

Steps
1. Route the VGA cable through the VGA module slot on the front of the system and slide the VGA module into the slot. 2. Align the hole on the module with the screw hole on the system. 3. Using the Phillips #1 screwdriver, secure the VGA module to the system with the screw.

Figure 87. Installing the VGA module
Next steps 1. Route the VGA cable and connect it to the VGA connector on the system board. For locating the connector, see the System
board jumpers and connecters section. 2. Install the air shroud. 3. Install the backplane cover. 4. Install the front bezel. 5. Follow the procedure listed in the After working inside your system on page 25. .
Optional optical drive
Removing the optical drive
The procedure for removing an optical drive and optical drive blank is the same.
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. If installed, remove the front bezel.
Steps 1. Disconnect the power and data cables from the connectors on the optical drive.
NOTE: Observe the routing of the cable as you remove it from the system.
2. To release the optical drive, press the release tab and push the drive towards the front of the system. 3. Slide the optical drive out of the system.

86

Installing and removing system components

Figure 88. Removing the optical drive
Next steps Replace the optical drive or Install an optical blank.
NOTE: Blanks must be installed on empty optical drive slot to maintain FCC certification of the system. The blank also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.
Installing the optical drive
The procedure for installing an optical drive and optical drive blank.
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. If applicable, remove the backplane cover. 4. If installed, remove the optical drive blank by pressing the blue release tab at the back of the blank and pushing the blank out
of the system. NOTE: Route the cable properly when you replace it to prevent the cable from being pinched or crimped.
Steps 1. Insert the optical drive until the blue release tab locks in the slot on the system. 2. Align the optical drive with the optical drive slot on the front of the system.

Installing and removing system components

87

Figure 89. Installing the optical drive
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
3. Connect the power and data cables to the connectors on the system board.
Next steps 1. If removed,install the front bezel. 2. Follow the procedure listed in After working inside your system on page 25.
Power supply unit
NOTE: While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals
Hot spare feature
Your system supports the hot spare feature that significantly reduces the power overhead associated with power supply unit (PSU) redundancy. When the hot spare feature is enabled, one of the redundant PSUs is switched to the sleep state. The active PSU supports 100 percent of the system load, thus operating at higher efficiency. The PSU in the sleep state monitors output voltage of the active PSU. If the output voltage of the active PSU drops, the PSU in the sleep state returns to an active output state. If having both PSUs active is more efficient than having one PSU in the sleep state, the active PSU can also activate the sleeping PSU. The default PSU settings are as follows:  If the load on the active PSU is more than 50 percent of PSU rated power wattage, then the redundant PSU is switched to
the active state.

88

Installing and removing system components

 If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to the sleep state.
You can configure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC User's Guide available at www.dell.com/poweredgemanuals.
Removing a power supply unit blank
Prerequisites Follow the safety guidelines listed in the Safety instructions on page 24.
Steps Pull the blank out of the system.
CAUTION: To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a nonredundant configuration. Remove the PSU blank only if you are installing a second PSU.

Figure 90. Removing a power supply unit blank
Next steps Replace the PSU or PSU blank.
Installing a power supply unit blank
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24.
NOTE: Install the power supply unit (PSU) blank only in the second PSU bay. 2. Remove the PSU. Steps Align the PSU blank with the PSU bay and push it into the PSU bay until it clicks into place.

Installing and removing system components

89

Figure 91. Installing a power supply unit blank
Removing a power supply unit
Prerequisites CAUTION: The system requires one power supply unit (PSU) for normal operation. On power-redundant systems, remove and replace only one PSU at a time in a system that is powered on.
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Disconnect the power cable from the power outlet and from the PSU you intend to remove. 3. Remove the cable from the strap on the PSU handle. 4. Unlatch and lift the optional cable management arm if it interferes with the PSU removal.
For information about the cable management arm, see the system's rack documentation at https://www.dell.com/ poweredgemanuals.
Steps Press the release latch, and holding the PSU handle slide the PSU out of the PSU bay.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

Figure 92. Removing a power supply unit

90

Installing and removing system components

Next steps Replace the PSU or install the PSU blank.
Installing a power supply unit
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. For systems that support redundant PSU, ensure that both the PSUs are of the same type and have the same maximum
output power. NOTE: The maximum output power (shown in watts) is listed on the PSU label.
3. Remove the PSU blank.
Steps Slide the PSU into the PSU bay until the release latch snaps into place.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

Figure 93. Installing a power supply unit
Next steps 1. If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the
system's rack documentation at https://www.dell.com/poweredgemanuals. 2. Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION: When connecting the power cable to the PSU, secure the cable to the PSU with the strap.
NOTE: When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds for the system to recognize the PSU and determine its status. The PSU redundancy may not occur until discovery is complete. The PSU status indicator turns green to indicate that the PSU is functioning properly. NOTE: For certain premium configurations with high power consumption, system PSU might stay with 2+0 mode only, 1+1 redundant mode is not available. NOTE: While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals

Installing and removing system components

91

Power interposer board
Removing the power interposer board
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the air shroud. 4. Remove the PSU or PSU blank.
Steps 1. Using a Phillips #2 screwdriver, remove the screws securing the power interposer board (PIB) to the system.
NOTE: Observe the routing of the cable as you remove it from the system.
2. Press the blue release latch on the PIB to release it from the hook on the PSU cage.

Figure 94. Removing the power interposer board
3. Lift the PIB away from the system.
Next steps Replace the power interposer board.
Installing the power interposer board
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25.
Steps 1. Align the slots on the PIB with the hook on the PSU cage and slide it into place.

92

Installing and removing system components

2. Using Phillips #2 screwdriver, tighten the screws to secure the PIB to the system.

Figure 95. Installing the power interposer board
3. Route the cables and connect it to the system board.
Next steps 1. Install the PSU. 2. Install the air shroud. 3. Follow the procedure listed in After working inside your system on page 25.
System board
Removing the system board
Prerequisites CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted to create a recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you replace this system board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on your drives.
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. Remove the following components:
a. Air shroud b. Expansion cards c. Expansion card risers d. Mini PERC card e. IDSDM module f. Internal USB key (if installed) g. Processor h. Heat sink i. Memory modules

Installing and removing system components

93

j. LOM riser card k. Disconnect all cables from the system board.
CAUTION: Take care not to damage the system identification button while removing the system board from the system.
Steps 1. Using a Phillips #2 screwdriver, remove the screws securing the system board to the chassis. 2. Using the system board holder, slightly lift the system board, and then slide it toward the front of the chassis. 3. Lift the system board out of the chassis.

Figure 96. Removing the system board
Next steps Install the system board.
Installing the system board
Prerequisites NOTE: Before replacing the system board, replace the old iDRAC MAC address label in the Information tag with the iDRAC MAC address label of the replacement system board
1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in Before working inside your system on page 25. 3. If you are replacing the system board, remove all the components that are listed in the removing the system board section.
Steps 1. Unpack the new system board assembly.
CAUTION: Do not lift the system board by holding a memory module, processor, or other components.

94

Installing and removing system components

CAUTION: Take care not to damage the system identification button while placing the system board into the chassis.
2. Holding the system board holder, lower the system board it into the system. 3. Incline the system board at an angle and align the connectors with the slots on the rear of the chassis. 4. Slide the system board towards the rear of the chassis until the connectors are firmly seated in the slots. 5. Using a Phillips #2 screwdriver, fasten the screws that secure the system board to the chassis.

Figure 97. Installing the system board
Next steps 1. Replace the following components:
a. Trusted Platform Module (TPM) NOTE: The TPM Module must be replaced only while installing new system board.
b. Mini PERC card c. IDSDM module d. Expansion cards e. Expansion card risers f. Processor g. Heat sink h. Memory modules i. LOM riser card j. Air shroud 2. Reconnect all cables to the system board.
NOTE: Ensure that the cables inside the system are routed along the chassis wall and secured using the cable securing bracket. 3. Ensure that you perform the following steps: a. Use the Easy Restore feature to restore the Service Tag. See the Restoring the system by using the Easy Restore feature section.

Installing and removing system components

95

b. If the service tag is not backed up in the backup flash device, enter the system service tag manually. See the Manually update the Service Tag by using System Setup section.
c. Update the BIOS and iDRAC versions. Re-enable the Trusted Platform Module (TPM). See the Upgrading the Trusted Platform Modulesection.
4. If you are not using Easy restore, import your new or existing iDRAC Enterprise license. For more information, see the iDRAC User's Guide available at https://www.dell.com/idracmanuals .
5. Follow the procedure listed in After working inside your system on page 25.
Restoring Service Tag using Easy Restore
The Easy Restore feature allows you to restore your Service Tag, iDRAC license, UEFI configuration, and the system configuration data after replacing the system board. All data is backed up in a backup Flash drive device automatically. If BIOS detects a new system board, and the Service Tag in the backup Flash drive device is different, BIOS prompts the user to restore the backup information.
About this task Below is a list of options available: 1. Restore the Service Tag, license, and diagnostics information, press Y. 2. Navigate to the Lifecycle Controller based restore options, press N. 3. Restore data from a previously created Hardware Server Profile, press F10.
NOTE: When the restore process is complete, BIOS prompts to restore the system configuration data. 4. To restore the system configuration data, press Y 5. To use the default configuration settings, press N
NOTE: After the restore process is complete, system reboots.
NOTE: If restoring the Service Tag is successful, you can check the Service Tag information in the System Information screen and compare it with the Service Tag on the system.
Manually updating Service Tag
After replacing a system board, if Easy Restore fails, follow this process to manually enter the Service Tag, using System Setup.
About this task If you know the system Service Tag, use the System Setup menu to enter the Service Tag.
Steps 1. Turn on the system. 2. To enter the System Setup, press F2. 3. Click Service Tag Settings. 4. Enter the Service Tag.
NOTE: You can enter the Service Tag only when the Service Tag field is empty. Ensure that you enter the correct Service Tag. After the Service Tag is entered, it cannot be updated or changed.
5. Click OK.

96

Installing and removing system components

Trusted Platform Module
Upgrading the Trusted Platform Module
Prerequisites NOTE:  Ensure that your operating system supports the version of the TPM module being installed.  Ensure that you download and install the latest BIOS firmware on your system.  Ensure that the BIOS is configured to enable UEFI boot mode.
About this task CAUTION: Once the TPM plug-in module is installed, it is cryptographically bound to that specific system board. Any attempt to remove an installed TPM plug-in module breaks the cryptographic binding, the removed TPM cannot be reinstalled or installed on another system board.
Removing the TPM
Steps 1. Locate the TPM connector on the system board. 2. Press to hold the module down and remove the screw using the security Torx 8-bit shipped with the TPM module. 3. Slide the TPM module out from its connector. 4. Push the plastic rivet away from the TPM connector and rotate it 90° counterclockwise to release it from the system board. 5. Pull the plastic rivet out of its slot on the system board.
Installing the TPM
Steps 1. To install the TPM, align the edge connectors on the TPM with the slot on the TPM connector. 2. Insert the TPM into the TPM connector such that the plastic rivet aligns with the slot on the system board. 3. Press the plastic rivet until the rivet snaps into place. 4. Replace the screw that secures the TPM to the system board.

Figure 98. Installing the TPM

Installing and removing system components

97

Initializing TPM for users
Steps 1. Initialize the TPM.
For more information, see Initializing the TPM for users. 2. The TPM Status changes to Enabled, Activated.
Initializing the TPM 1.2 for users
Steps 1. While booting your system, press F2 to enter System Setup. 2. On the System Setup Main Menu screen, click System BIOS > System Security Settings. 3. From the TPM Security option, select On with Preboot Measurements. 4. From the TPM Command option, select Activate. 5. Save the settings. 6. Restart your system.
Initializing the TPM 2.0 for users
Steps 1. While booting your system, press F2 to enter System Setup. 2. On the System Setup Main Menu screen, click System BIOS > System Security Settings. 3. From the TPM Security option, select On. 4. Save the settings. 5. Restart your system.
Control panel
Removing the left control panel
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. If applicable, remove the backplane cover 4. Remove the air shroud.
Steps 1. Disconnect the control panel cable from the system board connector.
NOTE: Observe the routing of the cable as you remove it from the system.
2. Using a Phillips #1 screwdriver, remove the screws that secure the cable cover to the system. 3. Using the Phillips #1 screwdriver, remove the screws that secure the left control panel assembly to the system. 4. Hold the left control panel assembly and remove it from the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

98

Installing and removing system components

Figure 99. Removing the left control panel
Next steps Replace the left control panel.
Installing the left control panel
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25.
Steps 1. Route the control panel cable through the side wall and the guide slots in the system and connector on system board.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
2. Align and insert the left control panel assembly in the slot on the system. 3. Using the Phillips #1 screwdriver, tighten the screws that secure the left control panel assembly. 4. Using the Phillips #1 screwdriver, tighten the screws to secure the cable cover to the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.

Installing and removing system components

99

Figure 100. Installing the left control panel
Next steps 1. Replace the air shroud. 2. Install the backplane cover 3. Close and secure the cable guiding latch. 4. Follow the procedure listed in the After working inside your system on page 25.
Removing the right control panel
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. 3. If applicable, remove the backplane cover 4. Remove the air shroud. 5. Lift the cable guiding latch. Steps 1. Using the Phillips #1 screwdriver, remove the screws that secure the cable cover and lift the cover away from the system.
Figure 101. Removing the cable cover 2. Lift open the cable latch and disconnect the control panel cable from the connector on the system board.
NOTE: Observe the routing of the cable as you remove it from the system.
100 Installing and removing system components

3. Using the Phillips #1 screwdriver, remove the screws that secure the right control panel assembly. 4. Hold the right control panel assembly and remove it from the system.
Figure 102. Removing the right control panel Next steps Replace the right control panel.
Installing the right control panel
Prerequisites 1. Follow the safety guidelines listed in the Safety instructions on page 24. 2. Follow the procedure listed in the Before working inside your system on page 25. Steps 1. Route the control panel cable and VGA cable through the side wall of the system.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped. 2. Align and insert the right control panel assembly in the slot on the system. 3. Connect the control panel cable to the connector system board and secure it using cable latch. 4. Using the Phillips #1 screwdriver, tighten the screws that secure the right control panel assembly.
Installing and removing system components 101

Figure 103. Installing the cable cover 5. Connect the control panel cable to the system board and secure it using cable latch. 6. Install the cable cover and secure it in place with screws, using a Phillips #1 screwdriver.
Figure 104. Installing the right control panel Next steps 1. Replace the air shroud. 2. Install the backplane cover 3. Close and secure the cable guiding latch. 4. Follow the procedure listed in the After working inside your system on page 25.
102 Installing and removing system components

5
Jumpers and connectors
This topic provides some basic and specific information about jumpers and switches. It also describes the connectors on the various boardsboard in the system. Jumpers on the system board help to disable the system and reset the passwords. To install components and cables correctly, you must know the connectors on the system board.
Topics:
· System board connectors · System board jumper settings · Disabling a forgotten password
Jumpers and connectors 103

System board connectors

Figure 105. System board connectors 1. PCI card Slot 5 3. PWRD_EN (Jumpers) 5. LOM riser card 7. Riser slot 1A 9. System power 3 11. Fan 6 13. SATA_A/PCIE_A 15. PCIE-B 17. Processor 19. Fan 3 21. PCIE-F 23. Left control panel 25. Intrusion switch 27. System power 1 29. PIB signal 2 31. IDSDM
104 Jumpers and connectors

2. PCI card Slot 4 4. NVRAM_CLR (Jumpers) 6. Battery 8. Mini PERC 10. DIMMS for processor 12. Fan 5 14. Fan 4 16. SATA_B/PCIE_C 18. PCIE-D 20. PCIE-E 22. Fan 2 24. Front backplane signal 1 26. Internal USB 3.0 28. System power 2 30. PIB signal 1 32. Rear backplane/ ODD power

33. Front backplane signal 0 35. TPM

34. DIMMS for processor 36. Front video

System board jumper settings

For information about resetting the password jumper to disable a password, see the Disabling a forgotten password section.

Table 21. System board jumper settings

Jumper

Setting

PWRD_EN

Description The BIOS password feature is enabled.

NVRAM_CLR

The BIOS password feature is disabled. The BIOS password is now disabled and you are not allowed to set a new password.
The BIOS configuration settings are retained at system boot.

The BIOS configuration settings are cleared at system boot.

CAUTION: Be careful when changing the BIOS settings. The BIOS interface is designed for advanced users. Any change in the setting could prevent your system from starting correctly and you might have potential loss of data.
Disabling a forgotten password
The software security features of the system include a system password and a setup password. The password jumper enables or disables password features and clears any password(s) currently in use.
Prerequisites CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Steps 1. Power off the system, and all the attached peripherals, and disconnect the system from the electrical outlet. 2. Remove the system cover. 3. Move the jumper on the system board from pins 2 and 4 to pins 4 and 6. 4. Replace the system cover.
NOTE: The existing passwords are not disabled (erased) until the system boots with the jumper on pins 4 and 6. However, before you assign a new system and/or setup password, you must move the jumper back to pins 2 and 4.
NOTE: If you assign a new system and/or setup password with the jumper on pins 4 and 6, the system disables the new password(s) the next time it boots.
5. Reconnect the system and all the attached peripherals. 6. Power off the system. 7. Remove the system cover. 8. Move the jumper on the system board from pins 4 and 6 to pins 2 and 4. 9. Replace the system cover. 10. Reconnect the system to the electrical outlet and power on the system, and all the attached peripherals. 11. Assign a new system and/or setup password.

Jumpers and connectors 105

6
System diagnostics and indicator codes
The diagnostic indicators on the system front panel display system status during system startup.
Topics:
· Status LED indicators · System health and system ID indicator codes · iDRAC Quick Sync 2 indicator codes · iDRAC Direct LED indicator codes · LCD panel · NIC indicator codes · Power supply unit indicator codes · Drive indicator codes · Using system diagnostics
Status LED indicators
NOTE: The indicators display solid amber if any error occurs.

Figure 106. Status LED indicators

Table 22. Status LED indicators and descriptions

Icon

Description Drive indicator

Condition
The indicator turns solid amber if there is a drive error.

Corrective action
 Check the System Event Log to determine if the drive has an error.
 Run the appropriate Online Diagnostics test. Restart the system and run embedded diagnostics (ePSA).
 If the drives are configured in a RAID array, restart the system, and enter the host adapter configuration utility program.

Temperature indicator

The indicator turns solid amber if the system experiences a thermal error (for example, the ambient temperature is out of range or there is a fan failure).

Ensure that none of the following conditions exist:
 A cooling fan has been removed or has failed.  System cover, air shroud, or back filler bracket is
removed.  Ambient temperature is too high.  External airflow is obstructed.
If the problem persists, see the Getting help section.

106 System diagnostics and indicator codes

Table 22. Status LED indicators and descriptions (continued)

Icon

Description

Condition

Corrective action

Electrical indicator

The indicator turns solid amber if Check the System Event Log or system messages

the system experiences an

for the specific issue. If it is due to a problem with

electrical error (for example,

the PSU, check the LED on the PSU. Reseat the

voltage out of range, or a failed PSU.

power supply unit (PSU) or voltage regulator).

If the problem persists, see the Getting help section.

Memory indicator The indicator turns solid amber if a Check the System Event Log or system messages

memory error occurs.

for the location of the failed memory. Reseat the

memory module.

If the problem persists, see the Getting help section.

PCIe indicator

The indicator turns solid amber if a Restart the system. Update any required drivers for PCIe card experiences an error. the PCIe card. Reinstall the card.
If the problem persists, see the Getting help section.
NOTE: For more information about the supported PCIe cards, see the Expansion card installation guidelines section.

System health and system ID indicator codes
The system health and system ID indicator is located on the left control panel of the system.

Figure 107. System health and system ID indicator

Table 23. System health and system ID indicator codes

System health and system ID indicator code

Condition

Solid blue

Indicates that the system is powered on, is healthy, and system ID mode is not active. Press the system health and system ID button to switch to system ID mode.

Blinking blue

Indicates that the system ID mode is active. Press the system health and system ID button to switch to system health mode.

Solid amber

Indicates that the system is in fail-safe mode. If the problem persists, see the Getting help section.

Blinking amber

Indicates that the system is experiencing a fault. Check the System Event Log for specific error messages. For information about the event and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com > Look Up > Error Code, type the error code, and then click Look it up.

iDRAC Quick Sync 2 indicator codes
iDRAC Quick Sync 2 module (optional) is located on the left control panel of the system.

System diagnostics and indicator codes 107

Table 24. iDRAC Quick Sync 2 indicators and descriptions

iDRAC Quick Sync 2 indicator Condition code

Corrective action

Off (default state)

Indicates that the iDRAC Quick Sync 2 feature is powered off. Press the iDRAC Quick Sync 2 button to power on the iDRAC Quick Sync 2 feature.

If the LED fails to power on, reseat the left control panel flex cable and check. If the problem persists, see the Getting help section.

Solid white

Indicates that iDRAC Quick Sync 2 is

If the LED fails to power off, restart the system.

ready to communicate. Press the iDRAC If the problem persists, see the Getting help

Quick Sync 2 button to power off.

section.

Blinks white rapidly

Indicates data transfer activity.

If the indicator continues to blink indefinitely, see the Getting help section.

Blinks white slowly

Indicates that firmware update is in progress.

If the indicator continues to blink indefinitely, see the Getting help section.

Blinks white five times rapidly and then powers off
Solid amber Blinking amber

Indicates that the iDRAC Quick Sync 2 feature is disabled.
Indicates that the system is in fail-safe mode. Indicates that the iDRAC Quick Sync 2 hardware is not responding properly.

Check if iDRAC Quick Sync 2 feature is configured to be disabled by iDRAC. If the problem persists, see the Getting help section. www.dell.com/poweredgemanuals or Dell OpenManage Server Administrator User's Guide at https://www.dell.com/openmanagemanuals.
Restart the system. If the problem persists, see the Getting help section.
Restart the system. If the problem persists, see the Getting help section.

iDRAC Direct LED indicator codes

The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRAC subsystem.
You can configure iDRAC Direct by using a USB to micro USB (type AB) cable, which you can connect to your laptop or tablet. Cable length should not exceed 3 feet (0.91 meters). Performance could be affected by cable quality. The following table describes iDRAC Direct activity when the iDRAC Direct port is active:

Table 25. iDRAC Direct LED indicator codes

iDRAC Direct LED indicator code

Condition

Solid green for two seconds

Indicates that the laptop or tablet is connected.

Blinking green (on for two seconds and off for two seconds)

Indicates that the laptop or tablet connected is recognized.

Powers off

Indicates that the laptop or tablet is unplugged.

LCD panel
The LCD panel provides system information, status, and error messages to indicate if the system is functioning correctly or requires attention. The LCD panel is used to configure or view the iDRAC IP address of the system. For information about the event and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com > Look Up > Error Code, type the error code, and then click Look it up.. The LCD panel is available only on the optional front bezel. The optional front bezel is hot pluggable. The status and conditions of the LCD panel are outlined here:

108 System diagnostics and indicator codes

 The LCD backlight is white during normal operating conditions.  If there is an issue, the LCD backlight turns amber and displays an error code followed by descriptive text.
NOTE: If the system is connected to a power source and an error is detected, the LCD turns amber regardless of whether the system is powered on or off.  When the system powers off and there are no errors, the LCD enters the standby mode after five minutes of inactivity. Press any button on the LCD to power it on.  If the LCD panel stops responding, remove the bezel and reinstall it.
If the problem persists, see Getting help.
 The LCD backlight remains off if LCD messaging is powered off using the iDRAC utility, the LCD panel, or other tools.

Figure 108. LCD panel features

Table 26. LCD panel features

Item Button or display

Description

1

Left

Moves the cursor back in one-step increments.

2 Select

Selects the menu item highlighted by the cursor.

3 Right

Moves the cursor forward in one-step increments.

During message scrolling:
 Press and hold the right button to increase scrolling speed.  Release the button to stop.

NOTE: The display stops scrolling when the button is released. After 45 seconds of inactivity, the display starts scrolling.

4 LCD display

Displays the system information, status, and error messages or iDRAC IP address.

Viewing Home screen
The Home screen displays user-configurable information about the system. This screen is displayed during normal system operation when there are no status messages or errors. When the system turns off and there are no errors, LCD enters the standby mode after five minutes of inactivity. Press any button on the LCD to turn it on.
Steps 1. To view the Home screen, press one of the three navigation buttons (Select, Left, or Right). 2. To navigate to the Home screen from another menu, complete the following steps:
a. Press and hold the navigation button till the up arrow is displayed. b. Navigate to the Home icon using the up arrow . c. Select the Home icon. d. On the Home screen, press the Select button to enter the main menu.
Setup menu
NOTE: When you select an option in the Setup menu, you must confirm the option before proceeding to the next action.

System diagnostics and indicator codes 109

Table 27. Setup menu

Option

Description

iDRAC

Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available fields are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domain addresses. Two separate DNS entries are available.

Set error

Select SEL to view LCD error messages in a format that matches the IPMI description in the SEL. This enables you to match an LCD message with an SEL entry.

Select Simple to view LCD error messages in a simplified user-friendly description. For information about the event and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com > Look Up > Error Code, type the error code, and then click Look it up..

Set home

Select the default information to be displayed on the Home screen. See View menu section for the options and option items that can be set as the default on the Home screen.

View menu

NOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next action.

Table 28. View menu Option iDRAC IP
MAC Name Number Power
Temperature

Description
Displays the IPv4 or IPv6 addresses for iDRAC9. Addresses include DNS (Primary and Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).
Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Displays the name of the Host, Model, or User String for the system.
Displays the Asset tag or the Service tag for the system.
Displays the power output of the system in BTU/hr or Watts. The display format can be configured in the Set home submenu of the Setup menu.
Displays the temperature of the system in Celsius or Fahrenheit. The display format can be configured in the Set home submenu of the Setup menu.

NIC indicator codes
Each NIC on the back of the system has indicators that provide information about the activity and link status. The activity LED indicator indicates if data is flowing through the NIC, and the link LED indicator indicates the speed of the connected network.

Figure 109. NIC indicator codes 1. Link LED indicator 2. Activity LED indicator
Table 29. NIC indicator codes NIC indicator codes Link and activity indicators are off.

Condition Indicates that the NIC is not connected to the network.

110 System diagnostics and indicator codes

Table 29. NIC indicator codes (continued)

NIC indicator codes

Condition

Link indicator is green, and activity indicator is blinking Indicates that the NIC is connected to a valid network at its maximum

green.

port speed, and data is being sent or received.

Link indicator is amber, and activity indicator is blinking Indicates that the NIC is connected to a valid network at less than its

green.

maximum port speed, and data is being sent or received.

Link indicator is green, and activity indicator is off.

Indicates that the NIC is connected to a valid network at its maximum port speed, and data is not being sent or received.

Link indicator is amber, and activity indicator is off.

Indicates that the NIC is connected to a valid network at less than its maximum port speed, and data is mot being sent or received.

Link indicator is blinking green, and activity is off.

Indicates that the NIC identify is enabled through the NIC configuration utility.

Power supply unit indicator codes
AC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator. The indicator shows if power is present or if a power fault has occurred.

Figure 110. AC PSU status indicator 1. AC PSU status indicator/handle

Table 30. AC PSU status indicator codes

Power indicator codes Condition

Green

Indicates that a valid power source is connected to the PSU and the PSU is operational.

Blinking amber

Indicates an issue with the PSU.

Not powered on

Indicates that the power is not connected to the PSU.

Blinking green

Indicates that the firmware of the PSU is being updated. CAUTION: Do not disconnect the power cord or unplug the PSU when updating firmware. If firmware update is interrupted, the PSUs do not function.

Blinking green and powers off

When hot-plugging a PSU, it blinks green five times at a rate of 4 Hz and powers off. This indicates a PSU mismatch due to efficiency, feature set, health status, or supported voltage.
CAUTION: If two PSUs are installed, both the PSUs must have the same type of label; for example, Extended Power Performance (EPP) label. Mixing PSUs from previous generations of PowerEdge servers is not supported, even if the PSUs have the same power rating. This results in a PSU mismatch condition or failure to power on the system.
CAUTION: If two PSUs are used, they must be of the same type and have the same maximum output power.
CAUTION: When correcting a PSU mismatch, replace the PSU with the blinking indicator. Swapping the PSU to make a matched pair can result in an error condition and an unexpected system shutdown. To change from a high output configuration to a low output configuration or vice versa, you must power off the system.

System diagnostics and indicator codes 111

Table 30. AC PSU status indicator codes (continued) Power indicator codes Condition
CAUTION: AC PSUs support both 240 V and 120 V input voltages with the exception of Titanium PSUs, which support only 240 V. When two identical PSUs receive different input voltages, they can output different wattages, and trigger a mismatch.
Drive indicator codes
The LEDs on the drive carrier indicates the state of each drive. Each drive carrier has two LEDs: an activity LED (green) and a status LED (bicolor, green/amber). The activity LED blinks whenever the drive is accessed.

Figure 111. Drive indicators 1. Drive activity LED indicator 2. Drive status LED indicator 3. Drive capacity label
NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on.

NOTE: Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.

Table 31. Drive indicator codes Drive status indicator code Blinks green twice per second Off

Condition
Indicates that the drive is being identified or preparing for removal.
Indicates that the drive is ready for removal. NOTE: The drive status indicator remains off until all drives are initialized after the system is powered on. Drives are not ready for removal during this time.

Blinks green, amber, and then powers off

Indicates that there is an expected drive failure.

Blinks amber four times per second

Indicates that the drive has failed.

Blinks green slowly

Indicates that the drive is rebuilding.

Solid green

Indicates that the drive is online.

Blinks green for three seconds, amber for three seconds, Indicates that the rebuild has stopped. and then powers off after six seconds

Using system diagnostics
If you experience an issue with the system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test the system hardware without using additional equipment or risking data loss. If you are unable to fix the issue yourself, service and support personnel can use the diagnostics results to help you solve the issue.

112 System diagnostics and indicator codes

Dell Embedded System Diagnostics
NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics. The Embedded System Diagnostics provide a set of options for particular device groups or devices allowing you to:  Run tests automatically or in an interactive mode  Repeat tests  Display or save test results  Run thorough tests to introduce additional test options to provide extra information about the failed device(s)  View status messages that inform you if tests are completed successfully  View error messages that inform you of issues encountered during testing
Running the Embedded System Diagnostics from the Dell Lifecycle Controller
Steps 1. As the system boots, press F10. 2. Select Hardware Diagnostics  Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all the detected devices.
Running the Embedded System Diagnostics from Boot Manager
Run the Embedded System Diagnostics (ePSA) if your system does not boot.
Steps 1. When the system is booting, press F11. 2. Use the up arrow and down arrow keys to select System Utilities > Launch Diagnostics. 3. Alternatively, when the system is booting, press F10, select Hardware Diagnostics > Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all the detected devices.
Results

System diagnostic controls
Table 32. System diagnostic controls Menu Configuration
Results System health Event log

Description
Displays the configuration and status information of all detected devices.
Displays the results of all tests that are run.
Provides the current overview of the system performance.
Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded.

System diagnostics and indicator codes 113

7
Getting help
Topics:
· Recycling or End-of-Life service information · Contacting Dell · Accessing system information by using QRL · Receiving automated support with SupportAssist
Recycling or End-of-Life service information
Take back and recycling services are offered for this product in certain countries. If you want to dispose of system components, visit www.dell.com/recyclingworldwide and select the relevant country.
Contacting Dell
Dell provides online and telephone based support and service options. If you do not have an active internet connection, you can find Dell contact information on your purchase invoice, packing slip, bill or Dell product catalog. The availability of services varies depending on the country and product, and some services may not be available in your area. To contact Dell for sales, technical assistance, or customer service issues:
Steps 1. Go to www.dell.com/support/home. 2. Select your country from the drop-down menu on the lower right corner of the page. 3. For customized support:
a. Enter the system Service Tag in the Enter a Service Tag, Serial Number, Service Request, Model, or Keyword field.
b. Click Submit. The support page that lists the various support categories is displayed.
4. For general support: a. Select your product category. b. Select your product segment. c. Select your product. The support page that lists the various support categories is displayed.
5. For contact details of Dell Global Technical Support: a. Click Global Technical Support. b. The Contact Technical Support page is displayed with details to call, chat, or e-mail the Dell Global Technical Support team.
Accessing system information by using QRL
You can use the Quick Resource Locator (QRL) located on the information tag in the front of the R6515 system, to access information about Dell EMC PowerEdge R6515.There is also another QRL for accessing product information located on the top of the system cover.
Prerequisites Ensure that your smartphone or tablet has the QR code scanner installed.
114 Getting help

The QRL includes the following information about your system:  How-to videos  Reference materials, including the Installation and Service Manual, LCD diagnostics, and mechanical overview  The system service tag to quickly access the specific hardware configuration and warranty information  A direct link to Dell to contact technical assistance and sales teams Steps 1. Go to www.dell.com/qrl, and navigate to your specific product or 2. Use your smart phone or tablet to scan the model-specific Quick Resource (QR) code on your system or in the Quick
Resource Locator section.
Quick Resource Locator for PowerEdge R6515 system
Figure 112. Quick Resource Locator for PowerEdge R6515 system
Receiving automated support with SupportAssist
Dell EMC SupportAssist is an optional Dell EMC Services offering that automates technical support for your Dell EMC server, storage, and networking devices. By installing and setting up a SupportAssist application in your IT environment, you can receive the following benefits:  Automated issue detection -- SupportAssist monitors your Dell EMC devices and automatically detects hardware issues,
both proactively and predictively.  Automated case creation -- When an issue is detected, SupportAssist automatically opens a support case with Dell EMC
Technical Support.  Automated diagnostic collection -- SupportAssist automatically collects system state information from your devices and
uploads it securely to Dell EMC. This information is used by Dell EMC Technical Support to troubleshoot the issue.  Proactive contact -- A Dell EMC Technical Support agent contacts you about the support case and helps you resolve the
issue. The available benefits vary depending on the Dell EMC Service entitlement purchased for your device. For more information about SupportAssist, go to www.dell.com/supportassist.
Getting help 115

8

Documentation resources

This section provides information about the documentation resources for your system.
To view the document that is listed in the documentation resources table:  From the Dell EMC support site:
1. Click the documentation link that is provided in the Location column in the table. 2. Click the required product or product version.
NOTE: To locate the product name and model, see the front of your system. 3. On the Product Support page, click Manuals & documents.  Using search engines:  Type the name and version of the document in the search box.

Table 33. Additional documentation resources for your system

Task

Document

Location

Setting up your system

For more information about installing and securing the system into a rack, see the Rail Installation Guide included with your rail solution.

www.dell.com/poweredgemanuals

For information about setting up your system, see the Getting Started Guide document that is shipped with your system.

Configuring your system

For information about the iDRAC features, configuring and logging in to iDRAC, and managing your system remotely, see the Integrated Dell Remote Access Controller User's Guide.

www.dell.com/poweredgemanuals

For information about understanding Remote Access Controller Admin (RACADM) subcommands and supported RACADM interfaces, see the RACADM CLI Guide for iDRAC.

For information about Redfish and its protocol, supported schema, and Redfish Eventing implemented in iDRAC, see the Redfish API Guide.

For information about iDRAC property database group and object descriptions, see the Attribute Registry Guide.

For information about Intel QuickAssist Technology, see the Integrated Dell Remote Access Controller User's Guide.

116 Documentation resources

Table 33. Additional documentation resources for your system (continued)

Task

Document

Location

For information about earlier

www.dell.com/idracmanuals

versions of the iDRAC documents.

To identify the version of iDRAC available on your system, on the iDRAC web interface, click ? > About.

For information about installing the www.dell.com/

operating system, see the

operatingsystemmanuals

operating system documentation.

For information about updating drivers and firmware, see the Methods to download firmware and drivers section in this document.

www.dell.com/support/drivers

Managing your system

For information about systems management software offered by Dell, see the Dell OpenManage Systems Management Overview Guide.

www.dell.com/poweredgemanuals

For information about setting up, using, and troubleshooting OpenManage, see the Dell OpenManage Server Administrator User's Guide.

www.dell.com/ openmanagemanuals > OpenManage Server Administrator

For information about installing and using Dell SupportAssist, see the Dell EMC SupportAssist Enterprise User's Guide.

https://www.dell.com/ serviceabilitytools

For information about partner programs enterprise systems management, see the OpenManage Connections Enterprise Systems Management documents.

www.dell.com/ openmanagemanuals

Working with the Dell PowerEdge RAID controllers

For information about understanding the features of the Dell PowerEdge RAID controllers (PERC), Software RAID controllers, or BOSS card and deploying the cards, see the Storage controller documentation.

www.dell.com/ storagecontrollermanuals

Understanding event and error messages

For information about the event and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com > Look Up > Error Code, type the error code, and then click Look it up.

www.dell.com/qrl

Troubleshooting your For information about identifying

system

and troubleshooting the

PowerEdge server issues, see the

Server Troubleshooting Guide.

www.dell.com/poweredgemanuals

Documentation resources 117



References

AH XSL Formatter V6.5 MR2 for Windows (x64) : 6.5.5.31438 (2017/12/12 12:09JST) iLovePDF