the number of changes required to instruction manuals when. equipment designs are changed. ■ Equipped with auto-reference and remote zero-ad-justment functions A...

Fiber-optic Sensors - Panasonic Industry

Smart automation technology ... All models have an M18 male thread for easy and quick mount- ing. ... once the power is turned back on after setup changes. 42.

SENSORS - Panasonic Industry

All models have an M18 male thread for easy and quick mount- ing. Furthermore the models ... once the power is turned back on after setup changes. 36. IO-Link.

sf sensor en
Sensors for Factory Automation
Short Form
Short form
SENSORS

CONTENT

3

Page
IO-Link Sensors........................................................... 6 IO-Link. DP-100L · HG-C1000L · FX-550L. . . . . . . . . . . . . . . . . . . .  6 GX-300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
Photoelectric Sensors / Standard Sensors.......................... 12 CX-400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12 NX5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16 CY-100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18
Photoelectric Sensors / Miniature Sensors.........................20 EX-Z. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20 EX-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22 EX-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24 EX-30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  26 PM-25/45/65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  28 PM2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
Photoelectric Sensors / Trigonometric Sensors..................33 EQ-500. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  33 EQ-30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  35
Photoelectric Sensors / AREA Sensors ..............................36 NA1-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  36 NA1-PK5/ NA1-PK3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38
Fiber-optic Sensors......................................................40 FX-100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40 FX-301. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  42 FX-311. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  44 FX-500/550. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45
Standard Fibers..........................................................48 Fibers with integrated high-precision plug. . . . . . . . . . . . . . . . . . .  48 Threaded fibers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  50 Square head fibers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  51 Cylindrical fibers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  52 Fibers with sleeve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  53 Flat fibers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  54 Wide beam fibers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  55 Convergent reflective fibers for glass detection. . . . . . . . . . . . . . .  56 Heat-resistant fibers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  57 Chemical-resistant fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  58 Vacuum-resistant fibers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  58 Fibers for liquid leak/liquid detection. . . . . . . . . . . . . . . . . . . . . . .  59 Lens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  60
Fiber sensors Communication Units..................................61 Communication units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  61
Mark Sensors.............................................................62 LX-100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  62

Page
Laser Sensors............................................................64 EX-L200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  64 LS-400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 LS-500. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  68
Safety Sensors...........................................................70 SF4D.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  70 SF4B (V2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  73 SF4B-C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  76 SF4C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  78 SF2B/SF2C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  80 SG-P. . . . . . N.E W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  82 ST4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF-C21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  86 SF-C10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  87
Pressure & Flow Sensors...............................................88 DP-0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  88 DP-100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  90 DPC-100/ DPH-100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  92 DPC-L100 / DPH-L100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  94 FM-200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  96
Inductive Proximity Sensors...........................................98 GX-300 . . . . N.E W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  98 GX-M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  102 GX-F/H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Measurement Sensors................................................ 106 HG-S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  106 HG-C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  108 HL-G1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 HL-C2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 HG-T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 GP-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Ionizers/Electrostatic Sensors...................................... 118 ER-Q. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 ER-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 ER-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  121 ER-VW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  123 ER-V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  125 EC-G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  127 EF-S1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  128
Accessories............................................................. 129

Application examples
Electronics
Automotive
Woodworking industry
Packaging industry
Glass/Wafer production 003
People counting +
+Electronic part discharging

5

Everything from a single source
With over 100 years of innovation and manufacturing expertise, Panasonic Industry Europe remains committed to its vision of creating "A Better Life, A Better World." Panasonic can look back on decades of experience in the electronics industry and, thanks to its dedicated customer orientation, is a competent and reliable partner for customers throughout Europe when it comes to technical expertise in combination with solution orientation. As a provider of tailor-made solutions, we focus on offering our customers products and services in the Mobility, Living Space and Business sectors that make a difference thanks to our proprietary innovations.

Smart automation technology
The factory of the future will achieve new levels of productivity, effectiveness and profitability through comprehensive networking. Equipment and components from Panasonic Industry Europe offer leading-edge Industry 4.0 features, as connectivity, energy efficiency, reliability and sturdiness play a pivotal role in modern production environments.
The Panasonic Industry Europe portfolio not only offers key electronic components, devices, modules and software but also complete solutions for production lines in a wide variety of industries. Panasonic Industry`s comprehensive know-how along the entire value chain, combined with a corporate culture geared to customer needs, enables it to offer customerspecific solutions that extend beyond the products.
Our experience as a manufacturer and a sales partner for components and products allows us to share our experience with our customers. Customer wishes are specifically integrated into the development of new products, so that we can surpass our role as a supplier and become a competent, long-term partner for our customers.

A new performance class of innovative sensor technology
Over the past ten years, Panasonic has developed a wide range of high-quality sensors that fit into our portfolio of a provider of complete solutions for factory automation. Besides through-beam and retroreflective types, reflective sensors and optical fiber photoelectric sensors, we also offer laser and eddy current and contact analog sensors that provide precise measurement results even in the most complicated of applications.
Our delivery program also includes safety sensors, photoelectric sensors for special applications, inductive proximity switches and miniature pressure sensors for relative or differential pressure measurement, and ionizers for Electro Static Discharge (ESD) applications. Of course, we adapt our sensors to your individual requirements in order to ensure optimal functionality and efficiency.

Service
In addition to an expert hotline, the extensive service from Panasonic Industry Europe also includes workshops and on-site service to ensure that our sensors are used reliably and effectively.
Apart from the broad product portfolio of sensors, Panasonic Industry Europe also offers programmable logic controllers, touch terminals, drive technology, energy management systems, ionizers, automation components and many other products and complete solutions.

6 IO-LINK SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors

 Connection to the field level
The standardized IO-Link technology makes connection to the field level easier than ever before.

Accessories Sensors can communicate with the defined masters via EtherCAT, Profinet or EtherNet/IP.

IO-Link
DP-100L · HG-C1000L · FX-550L
Standardized connection to the field level

 Self-diagnosis function
IO-Link All IO-Link sensors from Panasonic have an integrated
Sensors
self-diagnosis function. The function monitors the function parameters specific to the sensor type and automatically outputs a warning signal if deviations from the specified behavior occur. Users save time because for maintenance it is sufficient to monitor only one signal instead of a number of sensor parameters.

Technical specifications
 HG-C1000L
Cable type M12 connector type Measuring range

Repeatability

Linearity Beam diameter Beam source Supply voltage
Switching and communication line (C/Q)
Control output (DO) Response time Degree of protection

Communication specification Baud rate Process data Transmission cycle time

Cable

Material Dimensions (HxWxD)

HG-C1030L3-P HG-C1030L3-P-J
30±5mm 10m
Approx. 50m

HG-C1050L3-P

HG-C1100L3-P

HG-C1200L3-P

HG-C1400L3-P

HG-C1050L3-P-J

HG-C1100L3-P-J

HG-C1200L3-P-J

HG-C1400L3-P-J

50±15mm

100±35mm

200±80mm

400±200mm

30m

70m

200m

300m (200-400mm) 800m (400-600mm)

±0.1% F.S.

±0.2% F.S.

±0.3% F.S.

Approx. 70m

Approx. 120m

Approx. 300m

Approx. 500m

Red semiconductor laser (655nm), Class 2 (JIS/IEC/GB)/Class II (FDA)

12 to 24V DC ±10%

IO-Link specification V1.1

COM3 (230.4kbit/s)

4 bytes

1ms

PNP open-collector transistor, max. 50mA

Switchable between high speed (1.5ms), standard (5ms), and high precision (10ms)

IP67

Cable type: 4-wire PVC cable, 2m M12 connector type: 4-wire PVC cable, 0.3m

Enclosure: die-cast aluminum, front cover: acrylic

44x20x25mm

7

 DP-100L

Pigtailed type

M12 connector type

Type

Low pressure type

High pressure type

Low pressure type

High pressure type

Model number

DP-101ZL3-M-P

DP-102ZL3-M-P

DP-101ZL3-M-P-C

DP-102ZL3-M-P-C

Rated pressure range (note 1)

-1 bar to 1 bar (-100.0 to +100.0kPa)

-1 bar to +10 bar (-0.100 to +1.0MPa)

-1 to 1 bar (-100.0 to +100.0kPa)

-1 bar to +10 bar (-0.100 to +1.0MPa)

Applicable fluid

Non-corrosive gas

Supply voltage

12 to 24V DC ±10%

Communication specification

IO-Link specification V1.1

Switching and communication Baud rate

line (C/Q)

Process data

COM3 (230.4kbit/s) 4 bytes

Transmission cycle time

1ms

Control output (DO)

PNP open-collector transistor, max. 50mA

Output operation

Normally open contact (NO) / normally closed contact (NC) selectable

Output modes

3 modes: EASY, hysteresis mode, window comparator mode

Hysteresis

Minimum 1 digit (variable)

Repeatability (within ±2 digits)

± 0.1% FS

± 0.2% FS

± 0.1% FS

± 0.2% FS

Response time

2.5ms, 5ms, 10ms, 25ms, 50ms, 100ms, 250ms, 500ms, 1000ms, 5000ms selectable by key operation

LED indicator

LED (orange)

Pressure port

M5 female thread

Material

Housing: PBT, LC display: Acrylic, Pressure port: SUS 303, thread: brass, buttons: silicon rubber

Connection method

Connector (note 2)

M12 connector

Dimensions (HxWxD)

30x30x42.5mm

Accessories

CN-14A-C2 pigtail type 2m: 1 pc.

M12 connector cable 0.3m: 1 pc.

Notes:

1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20°C. Reference pressure = 1atm 2.) The cable CN-14A-C2 is included

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
IO-Link Sensors

 FX-550L

Type

Model number

Supply voltage

Communication specification

Switching and communica- Baud rate

tion line (C/Q)

Process data

Transmission cycle time

Control output (DO)

Emitting element (modulated)

Response time

Sensitivity setting

Incident light sensitivity setting

Incident light intensity display range

Degree of protection

Ambient temperature

Connection method Material Dimensions (HxWxD)

Pigtailed type

M12 connector type

FX-551L3-P-C2

FX-551L3-P-J

12 to 24V DC ±10%

IO-Link specification V1.1

COM3 (230.4kbit/s)

4 bytes

1ms

PNP open-collector transistor, max. 50mA

Red LED (Peak emission wavelength: 660nm)

Adjustable. STD: min. 250s, LONG: min. 2ms, U-LG: min. 4ms, HYPR: min. 24ms

2-point teaching, limit teaching, full auto-teaching, manual adjustment

Incorporated, 4 steps

Adjustable. STD: 0 to 4000, LONG: 0 to 8000, U-LG / HYPR: 0 to 9999

IP40

-10 to +55°C

For 4 to 7 sensors in series connection: -10 to +50°C; for 8 to 16 sensors in series connection:: -10 to +45°C (no condensation or freezing). Storage: -20 to +70°C

0.2mm2 4-core cab tire cable, 2m

0.2mm2 4-core cab tire cable with M12 connector, 0.3m

Housing and protective cover: Polycarbonate; buttons: Polyacetal

34x10x75mm

8 IO-LINK SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

GX-300
Cylindrical Inductive sensor with IO-Link type

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 IOT ready

With the implemented IO-Link technology network integration

is easy. The IO-Link models can be used as normal digital PNP

output sensors or providing information about the sensor level

Modbus

Modbus

TCP

TCP

or the current sensor condition.via IO-Link interface. This is perfect for predictive maintenance and applications with higher expectations.

Typical field network

To PLC

To PLC

IO-Link Sensors

*CC-Link IE Field and CC-Link are trademarks of Mitsubishi Electric Corporation, and are controlled by the CC-Link Partner Association. DeviceNet and EtherNet/IP are registered trademarks of ODVA (Open DeviceNet Vender Association, Inc.). EtherCAT is a registered trademark of Beckhoff Automation GmbH. Modbus is a registered trademark of Schneider Automation, Inc.
master
Green indicator flashes in 1-second intervals during I/O-Link communication.

IO-Link Master Unit for CC-Link IE Field SC-LG2-CEF-P

GX-312M-A-P
IO-Link usage example 1
Using the process data, the sensor transmits the detection level (8 bits) to the host device over IO-Link.

IO-Link usage example 3

Wire disconnection

When wire breakage or short-circuit occurs, the sensor notifies the host device by using the IO-Link event notification function. This enables quick identification of malfunctioning part to ensure smooth maintenance.

ON/OFF signal +
Sensor information

IO-Link usage example 2
The IO-Link device has an IODD (IO Device Description) file containing identification information such as the device vendor's name and model number. Workers on the manufacturing floor can load and utilize this information.
Operation mode switching information
N.O.
N.C.
IO-Link usage example 4
The operation mode can be toggled between N.O. and N.C. using IO-Link communication.

9

 DC 3-wire type ( Shielded type)

Type

Model No. (note 2)

Normally Open

Rated sensing distance

Stable sensing distance (note 3)

Standard sensing object (note 7)

Hysteresis

Supply voltage (note 4)

Current consumption

Control output

Communication specification

Switching and communication line (C/Q)

Baud rate Process data

Transmission cycle time

Response Frequency (note 5)

Protection

Ambient temperature

Dimension (HxWxD)

Material

Connection method (note 6)

GX-308M-A-P- 1.5mm
0 to 1.2mm 8x8mm
2kHZ M8x37.8mm

Shielded type

Threaded type

GX-312M-A-P-

GX-318M-A-P-

2.0mm

5mm

0 to 1.6 mm

0 to 4 mm

12x12mm

18x18mm

Max. 10% of measurement distance

10-30V DC ±10% (note1)

max. 16mA

PNP open-collector transistor, 200mA (note 2)

IO-Link specification V1.1

COM3 (230.4kbit/s)

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)

0.4ms

1.5kHz

0.6kHz

IP67 (IEC)

-40 to +85°C

M12x47.1mm

M18x55.3mm

Case: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-], Sensing part: Polybutylene terephthalate (PBT)

Cable, 2m or 5m; M12 connector type; pigtail type

GX-330M-A-P- 10mm
0 to 8mm 30x30mm
0.4kHz M30x60.3mm

 DC 3-wire type (Shielded type, long sensing range)

Shielded type

Type

Long sensing range

Threaded type

Model No. (note 2) Rated sensing distance

Normally Open

GX-308MK-A-P- 2.0mm

GX-312MK-A-P- 4.0mm

GX-318MK-A-P- 8mm

GX-330MK-A-P- 15mm

Stable sensing distance (note 3) Standard sensing object (note 7) Hysteresis

0 to 1.6mm 8x8mm

0 to 3.2mm

0 to 6.4mm

12x12mm

18x18mm

Max. 15% of measurement distance

0 to 12mm 30x30mm

Supply voltage (note 4)

10-30V DC ±10% (note1)

Current consumption Control output

Communication specification

max. 16mA PNP open-collector transistor, 200mA (note 2)
IO-Link specification V1.1

Switching and communication line (C/Q)

Baud rate Process data

Transmission cycle time

Response Frequency (note 5)

1.5kHZ

COM3 (230.4kbit/s)

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)

0.4ms

1.kHz

0.5kHz

0.25kHz

Protection

IP67 (IEC)

Ambient temperature Dimension (HxWxD) Material Connection method (note 6)

M8x37.8mm

-40 to +85°C

M12x47.1mm

M18x55.3mm

Case: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-], Sensing part: Polybutylene terephthalate (PBT)

Cable, 2m or 5m; M12 connector type; pigtail type

M30x60.3mm

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C 2.) Suffix -P = PNP type 3.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 4.) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained 5.) The response frequency is an average value. 6.) Suffix -C5 = 5m cable / Suffix -J = Pigtail 0.3m with M12 connector / Suffix -Z = M12 connector type 7.) Standard sensing object = sheet steel, thickness: 1mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
IO-Link Sensors

10 IO-LINK SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors Measurement
Sensors Ionizers/ Electrostatic Sensors
Accessories
IO-Link Sensors

 DC 3-wire type (Non-shielded type)

Type

Model No. (note 2)

Normally Open

Rated sensing distance

Stable sensing distance (note 3)

Standard sensing object (note 7)

Hysteresis

Supply voltage (note 4)

Current consumption

Control output

Communication specification

Switching and communication line (C/Q)

Baud rate Process data

Transmission cycle time

Response Frequency (note 5)

Protection

Ambient temperature

Dimension (HxWxD)

Material

Connection method (note 6)

GX-308ML-A-P- 2.0mm
0 to 1.6 mm 8x8mm
1kHZ M8x37.8mm

Non-shielded type

Threaded type

GX-312ML-A-P-

GX-318ML-A-P-

5.0mm

10mm

0 to 4 mm

0 to 8 mm

12x12mm

18x18mm

Max. 10% of measurement distance

10-30V DC ±10% (note1)

max. 16mA

PNP open-collector transistor, 200mA (note 2)

IO-Link specification V1.1

COM3 (230.4kbit/s)

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)

0.4ms

0.8kHz

0.4kHz

IP67 (IEC)

-40 to +85°C

M12x47.1mm

M18x55.3mm

Case: Nickel-plated brass [stainless steel (SUS303) for GX-308ML(K)-], Sensing part: Polybutylene terephthalate (PBT)

Cable, 2m or 5m; M12 connector type; pigtail type

GX-330ML-A-P- 18mm
0 to 14.4 mm 30x30mm
0.1kHz M30x60.3mm

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C 2.) Suffix -P = PNP type 3.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 4.) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained 5.) The response frequency is an average value. 6.) Suffix -C5 = 5m cable
Suffix -J = Pigtail 0.3m with M12 connector Suffix -Z = M12 connector type 7.) Standard sensing object = sheet steel, thickness: 1mm

 DC 3-wire type (Non-shielded type, long sensing range)

Type

Model No. (note 2)

Normally Open

Rated sensing distance

Stable sensing distance (note 3)

Standard sensing object (note 7)

Hysteresis

Supply voltage (note 4)

Current consumption

Control output

Communication specification

Switching and communication line (C/Q)

Baud rate Process data

Transmission cycle time

Response Frequency (note 5)

Protection

Ambient temperature

Dimension (HxWxD)

Material

Connection method (note 6)

GX-308MLK-A-P- 4mm
0 to 3.2 mm 12x12mm
1.5kHZ M8x37.8mm

Non-shielded type

Long sensing range

Threaded type

GX-312MLK-A-P-

GX-318MLK-A-P-

8mm

16mm

0 to 6.4 mm

0 to 12.8 mm

24x24mm

48x48mm

Max. 15% of measurement distance

10-30V DC ±10% (note1)

max. 16mA

PNP open-collector transistor, 200mA (note 2)

IO-Link specification V1.1

COM3 (230.4kbit/s)

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)

0.4ms

1.kHz

0.5kHz

IP67 (IEC)

-40 to +85°C

M12x47.1mm

M18x55.3mm

Case: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-], Sensing part: Polybutylene terephthalate (PBT)

Cable, 2m or 5m; M12 connector type; pigtail type

GX-330MLK-A-P- 30mm
0 to 24 mm 90x90mm
0.25kHz M30x82.3mm

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C 2.) Suffix -P = PNP type 3.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 4.) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained 5.) The response frequency is an average value. 6.) Suffix -C5 = 5m cable
Suffix -J = Pigtail 0.3m with M12 connector Suffix -Z = M12 connector type 7.) Standard sensing object = sheet steel, thickness: 1mm

Services that make a difference

To ensure that our customers get the best out of our products and solutions we provide a complete package of services. Our experienced sales engineers, product specialists, product management and technical engineers consult on any new project and provide our customers with recommendations for the ideal products and solutions for each individual task. That is the reason why products and solutions of Panasonic Industry are considered highly reliable.

 Product & project consulting
 Feasibility studies  Local laboratory tests  Customizing  Installation support  Panasonic Academy

 Technical Support
 Warranty & claim handling
 Discontinuation consulting

12 PHOTOELECTRIC SENSORS / STANDARD SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

CX-400
A full lineup of world standard photoelectric sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Great lineup of 170 models
The CX-400 series has a high level of basic functionality and excellent cost performance. Moreover, a wide number of variations means that there is sure to be a sensor that fits your needs.

CX-400

Type CX-412q Thru-beam (long sensing range) CX-411q Thru-beam CX-493q Retroreflective (long sensing range) CX-491q Retroreflective (with polarizing filters) CX-482q Retroreflective (transparent object sensing) CX-481q Retroreflective (transparent object sensing) CX-422q Diffuse reflective (800mm type) CX-421q Diffuse reflective (300mm type) CX-424q Diffuse reflective (100mm type) CX-423q Diffuse reflective (narrow-view) CX-442q Adjustable range reflective CX-444q Adjustable range reflective CX-443q Adjustable range reflective CX-441q Adjustable range reflective (small spot)

Sensing range
5m 3m 0.1 ­ 2m 50 ­ 500mm 800mm 300mm 100mm 70 ­ 200mm 20 ­ 300mm 15 ­ 100mm 2 ­ 50mm 2 ­ 50mm

15m 10m

 Less processing
M8 plug-in connector type and M12 pigtailed type are available. This contributes to less time spent setting up. In addition, cable types are available with the following cable lengths: 0.5m, 2m, and 5m.

M8 connector Elbow type Straight

(2m / 5m) (2m / 5m)

M12 connector
cable Straight (2m / 5m)

Cable type 5m
2m

0.5 m
 Less power consumed
By relentlessly developing our technologies, we have been able to considerably reduce our sensors' power consumption.

60% Reduction

Output Connecting method (note 1)

NPN, PNP Cable type, M8 plug-in connector type, M12 pigtailed type

Old CX-482 25mA

New CX-482 10mA

Cable length of cable type (note 2) 0.5m, 2m, 5m
Notes: 1.) Only the cable type and M8 plug-in connector type are available for the adjustable range
reflective type. 2.) Only the 2m cable length type (standard) is available for the adjustable range reflective type.

 Compact size
The sensors are compact in size at 11.2x31x20mm (WxHxD). The mounting pitch is also at the world standard size of 25.4mm.

11.2mm

20mm

31mm

25.4mm

 Less resources used
Based on environmental considerations, simplified packaging is used in order to reduce waste.
In addition, the bag is made of polyethylene, which produces no toxic gases even when burned.

13

CX-41/42/49  Strong against oil and coolant liquids
The lens material for the thru-beam type, retroreflective type (excluding the CX-48) and the diffuse reflective type is made of a strong acrylic that resists the harmful effects of coolants. These sensors can be used with confidence even around metal processing machinery that disperses oil mists. The protection mechanism also conforms to IP67 (IEC).

 Strong against ethanol

CX-44/48

A strong, ethanol-resistant polycarbonate is used for the front and display covers. Safe even for installing near food processing machinery that disperses ethanol-based detergents. The protection mechanism also conforms to IP67 (IEC).

 Strong against interference
The interference prevention function allows two sensors to be mounted close together.

Typical applications
Detecting cars on conveyor lines

Detecting transparent bottles

Detecting labels

Detecting transparent glass bottles

CX-423

CX-481

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

Thru-beam type CX-412
Strong infrared beam
It realizes a 15m long-distance sensing range. Remarkable penetrating power enables applications such as package content detection.

Retroreflective type CX-493
Strongest sensing range in its class
A long 5m sensing range is possible with the red LED type that is easy to align with the beam axis. Can be used for wide automatic door shutters.

Diffuse reflective type CX-423 CX-481/482

Beam axis alignment made easy
These sensors realize a high luminance red LED spot that provides bright visibility enabling the sensing position to be checked at a glance. Because it has the small spot, approx. 2mm, even the minutest object can be accurately detected.

Introducing the transparent object sensing type sensor
Our unique optical system and transparent object sensing circuitry provide stable sensing of even thinner transparent objects than the conventional models.

CX-440

CX-441/443
Can sense differences as small as 0.4mm, with hysteresis of max. 2%
An advanced optical system provides sensing performance that is approx. 2.5 times more precise than conventional models. Even ultra small differences of 0.4mm can be detected accurately.

CX-44
Not affected by color
Both black and white objects can be sensed at almost the same distances. No adjuster control is needed, even when products of different colors are moving along the production line.

CX-442

CX-483

BGS/FGS functions make even the most challenging settings possible!

Background suppression BGS
When object and background are separated.

Foreground suppression FGS
When object and background are close together.

When the object is glossy or uneven.

0,4mm

2.5 times the sensing capability
Height differences of as little as 0.4mm can be detected at a setting distance of 20mm.

30 % higher sensing capability

14 PHOTOELECTRIC SENSORS / STANDARD SENSORS

IO-Link Technical specifications
Sensors

Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors Measurement
Sensors Ionizers/ Electrostatic Sensors
Accessories
CX-400

Type

Model no.

NPN output
PNP output

Sensing range

Object to be sensed

Hysteresis

CX-411(-Z) (note 1)
CX-411-P(-Z)

Thru-beam

Long sensing range

CX-412(-Z)

CX-413(-Z)

CX-412-P(-Z)

CX-413-P(-Z)

With polarizing filter
CX-491(-Z)

Long sensing range CX-493(-Z)

Retroreflective

For transparent object sensing

CX-481(-Z)

CX-483(-Z)

CX-482(-Z)

CX-491-P(-Z)

CX-493-P(-Z)

CX-481-P(-Z)

CX-483-P(-Z)

CX-482-P(-Z)

10m

15m

30m

Min. Ø 12mm (opaque)

3m (note 2)

5m (note 2) 50 to 500mm (note 2) 50 to 1.0m (note 2) 0.1 to 2m (note 2)

Min. Ø 50mm (opaque, transparent)
(note 2)

Min. Ø 50mm (opaque, transparent or specular) (note 2)

­

Supply voltage

12 to 24VDC ±10%

Output
Output operation
Response time

Max. 1ms

PNP / NPN open-collector transistor, max. 100mA

Switchable either Light-ON or Dark-ON

Max. 2ms

Max. 1ms

Emitting element
Automatic interference prevention function

Red LED
Two units of sensors can be mounted close
together with interference prevention filters. (Sensing range: 5m)

Infrared LED ­

Red LED

Infrared LED

Incorporated (two sensor units can be mounted close together.)

Protection

IP67 (IEC)

Ambient temperature

­25 to +55°C

Material

Enclosure: PBT, Lens: Polycarbonate (CX-48p: Polycarbonate), Protection cover: Polycarbonate (CX-48p: Polycarbonate)

Connection method

2m cable, Suffix - Z: M8 connector (note 3)

Dimensions (HxWxD)

31x11.2x20mm (-Z connector type: 35.5x11.2x20mm)

Accessories

­

Notes: 1.) Suffix -Z = M8 connector type 2.) The sensing range is specified for the attached reflector RF-230 3.) Cable is not included in delivery. Please select under accessories (page 129)

Reflector: RF-230 1 pc.

15

Type

Model no.

NPN output
PNP output

Sensing range

Object to be sensed Hysteresis Supply voltage

CX-424(-Z) (note 1)
CX-424-P(-Z)
100mm

Diffuse reflective

CX-421(-Z) CX-421-P(-Z)

CX-422(-Z) CX-422-P(-Z)

300mm

800mm

Opaque, transparent Max. 15% of sensing range

Narrow view CX-423(-Z)

Adjustable range reflective (note 2) Small spot

CX-441(-Z)

CX-444(-Z)

CX-442(-Z)

CX-423-P(-Z) 70 to 300mm
12 to 24VDC ±10%

CX-441-P(-Z)
2 to 50mm (adjustable range:
20-50mm)

CX-444-P(-Z)
15 to100mm (adjustable range:
20-100mm)
­

Max. 2% of sensing range

CX-442-P(-Z)
20 to 300mm (adjustable range:
40-300mm)
Max. 5% of sensing range

Output
Output operation
Response time

PNP / NPN open-collector transistor, max. 100mA Switchable either Light-ON or Dark-ON Max. 1ms

Emitting element
Automatic interference prevention function
Protection
Ambient temperature
Material

Infrared LED

Red LED

Red LED

Incorporated (two sensor units can be mounted close together.)

IP67 (IEC) ­25 to +55°C Enclosure: PBT, Lens: Polycarbonate (CX-48p: Polycarbonate), Protection cover: Polycarbonate (CX-48p: Polycarbonate)

Connection method

2m cable, Suffix - Z: M8 connector (note 3)

Dimensions (HxWxD)

31x11.2x20mm (-Z connector type: 35.5x11.2x20mm)

Notes: 1.) Suffix -Z = M8 connector type 2.) FGS = Foreground suppression
BGS = Background suppression Selectable by wiring the inputs correspondingly 3.) Cable is not included in delivery. Please select under accessories (page 129)

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
CX-440

16 PHOTOELECTRIC SENSORS / STANDARD SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors

 Multi-voltage
24 to 240VAC and 12 to 240VDC, suitable for supply voltages all over the world.

Accessories NX5

 High reliability
The hermetically sealed output relay significantly increases its reliability.

Hermetically sealed relay eliminates worries about bad contact

NX5
Sensor usable world-wide

 Interference prevention
Two sensors operate normally even when mounted close together (excluding the 30m thru-beam type sensor).
 Long sensing range
Suitable for conveyor lines and parking lot applications.

Thru-beam Retroreflective

10m (Red LED)
30m (Infrared LED) 5m (Red LED with polarizing filters)
7m (Infrared LED)

Diffuse reflective

700mm (Infrared LED)

Typical applications
Multistoried parking
Detects if the car is protruding from the elevator door.

Golf driving range
The sensor detects the presence of a golf ball. The sensor is multi-voltage type so no DC power supply is needed.

NX5-M10RA

Arresting shutter closing
The long sensing range sensor with a visible red beam can be used to control the shutter operation at the gate of a factory.
NX5-M10RA

Arresting door closing
The sensor detects a person or an object and prevents the door from closing as long as its beam is interrupted.

17

Technical specifications

IO-Link

Sensors

Thru-beam

Retroreflective

Photoelectric Sensors

Type

Diffuse reflective

Long sensing range

With polarizing filters

Long sensing range

Fiber-optic Sensors

Model no.

NX5-M10RA NX5-M10RB NX5-M30A NX5-M30B NX5-PRVM5A NX5-PRVM5B NX5-RM7A NX5-RM7B NX5-D700A NX5-D700B

Standard Fibers

Sensing range Object to be sensed Hysteresis

10m

30m

Min. Ø 20mm (opaque transparent) (note 3)

0.1 to 5m (note 1)

0.1 to 7m (note 1)

700mm (note 2)

Min. Ø 50mm (opaque, semitransparent or
transparent) (note 1, 3)

Min. Ø 50mm (opaque or translucent) (note 1, 3)

Opaque, semitransparent or transparent (note 3)

--

Max. 15% of sensing range

Fiber Sensors Communication Units
Mark Sensors
Laser Sensors

Repeatability (perpendicular to sensing axis) Supply voltage Power consumption
Output

Max. 0.1mm

Max. 0.2mm

Max. 0.3mm

24 to 240VAC ± 10%, or 12 to 240VDC ± 10%

Emitter: max. 1VA Receiver: max. 2VA

Emitter: max. 1.5VA Receiver: max. 2VA

Max. 2VA

Relay contact 1c Switching capacity: Electrical life: Mechnical life:

250VAC 1A (resistive load) 30VDC 2A (resistive load) Min. 500000 switching operations (switching frequency 3600 operations/hour) Min. 100 million switching operations (switching frequency 36000 operations/hour)

Output operation

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

Response time
Power indicator
Sensitivity adjuster Automatic interference prevention function

--
Continuously variable adjuster
Use optional interference prevention filters

Red LED (lights up when the
power is ON)
--
--

Max. 10ms

--

NX5

Continuously variable adjuster

--

Continuously variable adjuster

Incorporated (two sensor units can be mounted close together.)

Protection

IP66 (IEC)

Ambient temperature

­20 to +55°C

Emitting element

Red LED

Infrared LED

Red LED

Infrared LED

Material

Enclosure: Polycarbonate; lens: polycarbonate; cover: polycarbonate; front cover (retroreflective type sensor only): Acrylic

Connection method

5-core (thru-beam type emitter: 2 cable) cable, 2m

Dimensions (HxWxD) Accessories

Adjusting screwdriver: 1 pc.

62x18x35mm

--

Reflector RF-230: 1 pc. Adjusting screwdriver: 1 pc.

Reflector RF-230: 1 pc.

Adjusting screwdriver: 1 pc.

Reflector cannot be placed in this range
Sensor

Actual sensing range of the 5m (NX5-RM7: 7m) sensor
0.1m Setting range of the reflector

Reflector

Reflector

Notes: 1.) The sensing range and the object to be sensed of the retroreflective type sensor is specified for the RF-230
Further, the sensing range is the possible setting range for the reflector The sensor can also detect an object 0.1m, or more, away 2.) The sensing range is specified for white non-glossy paper (200x200mm) 3.) Check the functionality with a real object

18 PHOTOELECTRIC SENSORS / STANDARD SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

CY-100
Simple mounting with M18 thread

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Wide product range
The availability of a wide range of models within the series means the CY-100 sensors can solve relatively complex tasks. Types with integrated polarization filters can even recognize reflective objects. The side view type makes applications possible in cramped spaces.

CY-100  M18 Thread
All models have an M18 male thread for easy and quick mounting. Furthermore the models are also available for the M12 connector type. You can easily replace and add these standard models. The nuts are included in delivery.

 Long sensing range
The thru-beam and retroreflective types of the CY-100 have a large sensing range of up to 15m.
 Environmentally robust
Thanks to the IP67 (IEC) casing, the sensor is suitable for installation in humid and dusty environments. Integrated status LEDs allow the operator to check the function of the sensor at a glance.

Typical applications

Object detection

Detecting specular objects

Object counting

19

Technical specifications

 Standard type

Type

Model no. Sensing range

NPN output PNP output

Object to be sensed

Supply voltage Output Response time Emitting element Protection Ambient temperature Material Connection method

Dimensions (HxWxD)

Accessories

Thru-beam

Retroreflective type (note 3)

Diffuse

­

­

With polarizing filter

­

With sensitivity adjuster

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

CY-111A (-Z) (note 1)

CY-111B (-Z)

CY-192A (-Z)

CY-192B (-Z)

CY-191A (-Z)

CY-191B (-Z)

CY-121A (-Z)

CY-121B (-Z)

CY-122A (-Z)

CY-122B (-Z)

CY-111A-P (-Z) CY-111B-P (-Z) CY-192A-P (-Z) CY-192B-P (-Z) CY-191A-P (-Z) CY-191B-P (-Z) CY-121A-P (-Z) CY-121B-P (-Z) CY-122A-P (-Z) CY-122B-P (-Z)

15m

4m

2m

100mm (note 2)

600mm (note 2)

Min. Ø 18mm (opaque)

Min. Ø 50mm

Min. Ø 50mm (opaque, trans-

(opaque, transparent) (note 1) parent or specular) (note 1)

Opaque, transparent

12 to 24VDC ±10%

PNP / NPN open-collector transistor, max. 100mA

Max. 1ms

Infrared LED

Red LED

Infrared LED

IP67 (IEC)

­25 to +55°C

Enclosure: PBT, Lens: PMMA

2m cable, Suffix - Z: M12 connector (note 4)

M18x46mm, -Z connector type: M18x60mm Nuts 4 pcs.

M18 x 48mm, -Z connector type: M18x62mm
Nuts 2 pcs.

M18x46mm, -Z connector type: M18x60mm

M18x62mm, -Z connector type: M18x76mm
Nuts 2 pcs. Screwdriver 1pc.

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

 Side sensing type

Thru-beam

Retroreflective type (note 3)

Diffuse

Type

­

­

With polarizing filter

­

With sensitivity adjuster

Model no.

NPN output PNP output

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

CY-111VA(-Z) (note 1)

CY-111VB(-Z)

CY-192VA(-Z)

CY-192VB(-Z)

CY-191VA(-Z)

CY-191VB(-Z)

CY-121VA(-Z)

CY-121VB(-Z)

CY-122VA(-Z)

CY-122VB(-Z)

CY-111VA-P(-Z) CY-111VB-P(-Z) CY-192VA-P(-Z) CY-192VB-P(-Z) CY-191VA-P(-Z) CY-191VB-P(-Z) CY-121VA-P(-Z) CY-121VB-P(-Z) CY-122VA-P(-Z) CY-122VB-P(-Z)

Sensing range Object to be sensed Supply voltage

15m Min. Ø 18mm (opaque)

4m
Min. Ø 50mm (opaque, transparent) (note 1)

2m
Min. Ø 50mm (opaque, transparent or specular) (note 1)
12 to 24VDC ±10%

100mm (note 2)

600mm (note 2)

Opaque, transparent

Output

PNP / NPN open-collector transistor, max. 100mA

Response time

1ms

Emitting element

Infrared LED

Red LED

Infrared LED

Protection

IP67 (IEC)

Ambient temperature

­25 to +55°C

Material

Enclosure: PBT, Lens: PMMA

Connection method Dimensions (ØxD) Accessories

2m cable, Suffix - Z: M12 connector (note 4)

M18x62mm, -Z connector type: M18x76mm

M18x46mm,

-Z connector type:

­

M18x60mm

Nuts 4 pcs.

Nuts 2 pcs.

Notes: Suffix -Z = M12 connector type 1.) The sensing range and object to be sensed of the retroreflective type are specified for the reflector RF-420 (accessories page 130) 2.) The sensing range is specified for white, matt paper 3.) The reflector is not included in delivery; please order separately (accessories page 130) 4.) Cable not included in delivery, please order separately (accessories page 129)

M18x78mm, -Z connector type: M18x92mm
Nuts 2 pcs. Screwdriver 1 pc.

CY-100

20 PHOTOELECTRIC SENSORS / MINIATURE SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors Ionizers/
Electrostatic Sensors
Accessories
EX-Z

 Smallest laser sensor with a built-in amplifier
The extreme thinness of 3mm of the EX-Z series has been achieved by utilizing a new semiconductor packaging technology that does not use wire bonding. The small unit size allows the installation of sensors in a narrow space where only a conventional fiber sensor head could be installed before. As opposed to a fiber sensor, the EX-Z has a built-in amplifier, which also saves on installation space.

EX-Z
Miniature thru-beam sensor with built-in amplifier

Front sensing
Approx.
50% smaller than EX-10
EX-Z1F
H14×W8×D3 mm

Side sensing
Approx.
35% smaller than EX-10
EX-Z1
H15.9×W5.5×D6.5 mm

 Sensing extremely small objects
Thanks to the integrated slit mask, the sensor can detect objects with a diameter of as little as 0.3mm. Even at a distance of 500mm, the sensor is capable of reliably detecting objects as small as 1mm.

Integrated slit mask
EX-Z11
Slit diameter: 0.3mm

Detecting the end of a thin tube

 Easy to install
The clearly visible red light beam makes installation and beam alignment very simple. The 4-element LED provides a stable strong light over a long period of time.
 Great performance in an industrial environment
With IP67 degree of protection, the EX-Z can be installed in environments where water is used or splashed1. For this type of application, there are rustproof mounting brackets available in stainless steel and plastic.
1 If water splashes on the sensor during sensing operation, the sensor may detect the water as an object

Clearly visible spot

21

Detection of parts in parts feeder

Detection of presence / absence of Detection of LED contacts test tubes

Mounted on robot arm

Technical specifications
 Standard type
Type

Model number

Light-ON Dark-ON

Sensing range

Object to be sensed

Supply voltage

Output

Response time

Degree of protection

Ambient temperature

Connection method

Dimensions (HxWxD)

Accessories
Note: Suffix P= PNP output No suffix = NPN type

EX-Z11FA (-P) (note) EX-Z11FB (-P) 50mm Min. Ø 0.3mm

Front sensing EX-Z12FA (-P) EX-Z12FB (-P)
200mm Min. Ø 0.5mm
14x8x3mm

Thru-beam

Side sensing

EX-Z13FA (-P)

EX-Z11A (-P)

EX-Z12A (-P)

EX-Z13FB (-P)

EX-Z11B (-P)

EX-Z12B (-P)

500mm

50mm

200mm

Min. Ø 1.0mm

Min. Ø 0.3mm

Min. Ø 0.5mm

12 to 24V DC ±10%

NPN / PNP open-collector transistor, max. 20mA

Max. 0.5ms

IP67 (IEC)

-10 to +55°C

2m cable

15.5x5.5x6.5mm

Mounting screws, 1 set

EX-Z13A (-P) EX-Z13B (-P)
500mm Min. Ø 1.0mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
EX-Z

22 PHOTOELECTRIC SENSORS / MINIATURE SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

EX-10
The slimmest: 3.5mm thick

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Optimized precision optics
The enhanced EX-10 series offers a more precise light beam compared with the other standard models. Now you can realize an even more space saving installation, because no additional tools like slit masks are needed to prevent interferences. It is no problem to detect smallest objects with a diameter of 0.5mm.

 2-color indicator
A convenient bright, 2-color indicator has been incorporated in the miniature body. You can check the available power supply and current output operation at a glance.

EX-10

EX-11p / EX-11Ep

EX-11Sp / EX-11SEp
 Sensing range 1m: EX-19
 High-speed response time: 0.5ms
The sensor EX-10 with a response time of only 0.5ms is especially suitable for detecting small and high-speed traveling objects.
 Flexible setup
The EX-10 sensor is available as front sensing or side sensing type, allowing for flexible mounting in the narrowest of spaces.

2-colored status LEDs Orange: Operation Green: Stability

 Freely mountable fingertip size

3.5mm

10mm

14.5mm

Freely mountable; dimensions 10x14.5x3.5mm (WxHxD) (Thrubeam type, front sensing). Moreover, easy alignment is possible with the visible red LED beam source.

Typical applications

8

Detecting the float for a flow meter

Seating confirmation fiber

Detecting small parts such as screws

Sensing PCB rack

Amplifier built-in Ultra-slim photoelectric sensor EX-11B

Amplifier built in Ultra-slim photoelectric sensor
EX-14A

FOUP

EX-11EB

EX-19SB

23

Technical specifications

Type Model no. Sensing range

Front sensing
Side sensing

Object to be sensed

Supply voltage

Output

Output operation

Response time

Protection

Ambient temperature

Connection method

Dimensions (HxWxD)

Accessories
Note: Suffix -PN = PNP type No suffix = NPN type

EX-11A(-PN) (note)
EX-11EA(-PN)

EX-11B(-PN) EX-11EB(-PN)

150mm

Min. Ø 1mm (opaque)

Light-ON

Dark-ON

Thru-beam

EX-13A(-PN)

EX-13B(-PN)

EX-19A(-PN)

EX-19B(-PN)

EX-13EA(-PN)

EX-13EB(-PN)

EX-19EA(-PN)

EX-19EB(-PN)

500mm

1m

Min. Ø 2mm (opaque)

12 to 24V DC ±10 %

PNP/NPN open-collector transistor, max. 50mA

Light-ON

Dark-ON

Light-ON

Dark-ON

Max. 0.5ms

IP67 (IEC)

­25 to +55°C

2m cable

14.5x10x3.5mm

Mounting screws, 1 set

Convergent reflective

EX-14A(-PN)

EX-14B(-PN)

­

­

2 to 25mm (conv. point: 10mm)
Min. Ø 0.1mm copper wire (Setting distance: 10mm)

Light-ON

Dark-ON

13x14.5x3.5mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
EX-10

 Narrow-view type

Type

Model no.

Light-ON Dark-ON

Sensing range

Object to be sensed

Supply voltage

Output

Response time

Protection

Ambient temperature

Connection method

Dimensions (HxWxD)

Accessories
Note: Suffix -PN = PNP type No suffix = NPN type

Thru-beam

Front sensing

Side sensing

Front sensing

Side sensing

EX-11SA(-PN) (note)

EX-11SEA(-PN)

EX-13SA(-PN)

EX-13SEA(-PN)

EX-11SB(-PN)

EX-11SEB(-PN)

EX-13SB(-PN)

EX-13SEB(-PN)

Min. Ø 0.5mm (opaque)

150mm

Min. Ø 1.0mm (opaque)

500mm
Min. Ø 1.0mm (opaque)
12 to 24V DC ±10%

Min. Ø 2.0mm (opaque)

PNP/NPN open-collector transistor, max. 50mA

Max. 0.5ms

IP67 (IEC)

­25 to +55°C

2m cable

14.5x10x3.5mm

Mounting screws, 1 set

Front sensing
EX-19SA(-PN)
EX-19SB(-PN)
1m Min. Ø 2.0mm
(opaque)

24 PHOTOELECTRIC SENSORS / MINIATURE SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Long sensing range
The EX-20 series achieves long distance sensing [thru-beam type: 2m, retroreflective type: 200mm (when using the attached reflector), diffuse reflective type: 160mm], despite its miniature size. Hence, it is usable even on a wide conveyor.

 Clear beam spot using red LED dot light source
EX-20 The emission area of a dot light source is smaller than that of a conventional LED flat light source. It is possible to design a high power, narrow beam. Since a red LED dot light source is used, the red beam spot is clearly visible even at a long distance so that the alignment and confirmation of the sensing position is easy.

 Less power consumed!
By relentlessly developing our technologies, we have been able to considerably reduce our sensors' power consumption.

EX-20
Miniature-sized and still mountable with M3 screws

Sensing range:

80mm

5mm

Sensing range:

spot

1mm

10mm

spot

35 % Reduction

Typical applications
Checking protrusion of wafer
The ultra compact photoelectric sensor EX-23 has a sufficiently long sensing range of 2m. Further, its visible red LED beam makes beam alignment very easy.

Detecting tape feeder cassette out of position
Ultra compact in size with an ample sensing range of 2m, ideal for monitoring tape feeder cassettes that are out of position.

Detecting fill-up of parts in feeder
The sensor setting can be finely adjusted since a universal sensor mounting bracket is available, with which the height and the angle of the sensor can be freely adjusted.

Position

EX-23

incorrecte

EX-23

EX-23 MS-EX20-5

25

Technical specifications

Diffuse reflective type

Thru-beam

Retroreflective

Type

Standard type

Diffuse beam

Small spot beam

Long distance spot beam

Front sensing

Side sensing

Side sensing

Side sensing

Front sensing

Side sensing

Side sensing

Model no.

Light-ON Dark-ON

Sensing range

Object to be sensed

EX-21A(-PN) (note) EX-21B(-PN)

EX-23(-PN) Light-ON/ Dark-ON switchable

EX-29A(-PN) EX-29B(-PN)

EX-22A(-PN) EX-22B(-PN)

EX-24A(-PN) EX-24B(-PN)

EX-26A(-PN) EX-26B(-PN)

EX-28A(-PN) EX-28B(-PN)

1m

2m

30 to 200mm

5 to 160mm

2 to 25mm

6 to 14mm

(Conv. point: 10mm) (Conv. point: 10mm)

45 to 115mm

Min. Ø 2.6mm (opaque)

Min. Ø 3mm (opaque)

Min. Ø 15mm opaque Opaque, translucent or translucent object or transparent object

Min. Ø 0.1mm copper wire (Setting distance: 10mm)

Opaque, translucent or transparent object

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors

Supply voltage Output Response time Protection Ambient temperature Connection method

12 to 24VDC ± 10% PNP / NPN open-collector transistor, max. 50mA
Max. 0.5ms IP67 (IEC) ­25 to +55°C Cable 2m

Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

Dimensions (HxWxD)
Accessories
Note: Suffix -PN = PNP type No suffix = NPN type

18x16x4.5mm ­

8.2x22x10.5mm

8.2x25x12.3mm

Screwdriver, 1 pc.

Reflector RF-200, 1 pc. Screwdriver, 1 pc.

Screwdriver, 1 pc.

16x18x4.5mm ­

8.2x25x12.3mm

10x14.5x3.5mm

Screwdriver, 1 pc.

EX-20

26 PHOTOELECTRIC SENSORS / MINIATURE SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

EX-30
An alternative to fiber sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 An alternative to fiber sensors
The EX-30 series can be screw-mounted (M4 for thru-beam type, M6 for reflective type). This means that they can be inserted into production lines in exactly the same way as conventional fiber sensors.

 800mm thru-beam type available
EX-30 The sensing range is 1.5 times greater than previous models! It also has a sensitivity adjuster to enable compatibility with a wide range of applications.

 Less power consumed!
By relentlessly developing our technologies, we have been able to considerably reduce our sensors' power consumption.
35 % Reduction

Typical applications
Detecting quantity of labels in label magazine
Detects the remaining amount of labels by the thickness of the roll.
EX-31A

Detecting ICs
Detects whether ICs are accurately placed in IC trays.
EX-31A

Resin bottle detection
The EX-32A threaded photoe lectric sensor confirms the arrival of bottles.

Bottle detection

Bottle discharge confirmation
Bottle arrival confirmation

FT-SFM2

EX-32A

Bottle orientation discrimination

Orientation switching apparatus

90deg turn

Discharge

27

Technical specifications

Model no.

Type NPN output PNP output Sensing range Object to be sensed Supply voltage Output Output operation Response time Protection Ambient temperature Connection method Dimensions (HxWxD) Accessories

EX-31A EX-31A-PN
Light-ON

Thru-beam EX-31B

EX-33

EX-32A

Diffuse reflective

EX-32B

EX-31B-PN

EX-33-PN

EX-32A-PN

EX-32B-PN

500mm

800mm

50mm

Min. 2mm (or opaque)

Opaque, translucent or transparent object

12 to 24VDC ± 10%

PNP / NPN open-collector transistor, max. 50mA

Dark-ON

Variable switching method

Light-ON

Dark-ON

Max. 0.5ms

IP67 (IEC)

-25 to +55°C

Cable 2m

14x15.6x18mm

Nuts, 2 pcs.; washers, 2 pcs.

Nut, 1 pc.; washer, 1 pc.

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
EX-30

28 PHOTOELECTRIC SENSORS / MINIATURE SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

PM-25/45/65
Enables equipment miniaturization and quick construction

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors Ionizers/
Electrostatic Sensors
Accessories
PM-25/45/65

 Increased beam emitting / receiving distance of 6mm

The beam emitting and receiving sections are 0.5mm thinner

compared to our conventional

models although the external dimensions have not changed.

13.4

6

3.7

As a result, the distance

between the beam-emitting

and the beam-receiving point

increased by 1mm. The wider

distance means less possibility of collision with the object to be

(Unit: mm)

sensed.

 Large and easy-to-see operation indicator
The large operation indicator (orange) lights up when an object enters the beam axis. The indicator is easy to see from any angle ­ even from above and from the sides.

Typical applications
Positioning of a pallet

 Beam marks for easy adjustment
There are marks on the front and back of the sensor to indicate the upper and the lower limit of the beam axis. This makes it easy to adjust the position of the object to be sensed.

Three protection circuits standard on all models

Ample beam emitting / receiving distance of 6mm

6mm

Industry's first! IP64 rating
Large and easy to see: Multi-angle operation indicator
Compact size

All models easy to mount with M3 screws

Beam marks for easy adjustment

Sensing the starting point on a rotating body

Index
Index

Order guide
Type

Dimensions (mm)

K type

6

23,9

12,3

Ultrasmall / Cable tyoe

L type F type R type U type
Type K type T type L type Y type F type R type

13,4 11,7
13,4 11,7
13,4

12 12
12,5
12,5

6 16 13,4

Dimensions (mm)

7

25,4

21,3

13,7

26

18,1

14,6 26
7
14,6
20,6 13,4

13 13,7
13,7

21,3 13 21,3

Compact / Cable type

Model no. PM-K25 PM-K25-P PM-L25 PM-L25-P PM-F25 PM-F25-P PM-R25 PM-R25-P PM-U25 PM-U25-P Model no. PM-K45 PM-K45-P PM-T45 PM-T45-P PM-L45 PM-L45-P PM-Y45 PM-Y45-P PM-F45 PM-F45-P PM-R45 PM-R45-P

Connector type

Type K type T type L type Y type F type
R type

29

Dimensions (mm)

7

26

22,4

26 22,4

13,7 22,4
16,7

26

26,2 13,4

14,9 15,7
14,9
22,7

13,5 22,4
13,4

13 13,4
13,5 13,4

22,4 22,4

13 22,4
13,4

Model no. PM-K65 PM-K65-P PM-T65 PM-T65-P PM-T65-W PM-T65W-P PM-L65 PM-L65-P PM-Y65 PM-Y65-P

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
PM-25/45/65

PM-F65

PM-F65-P

PM-F65W

PM-F65W-P

PM-R65

PM-R65-P

PM-R65W

PM-R65W-P

30 PHOTOELECTRIC SENSORS / MINIATURE SENSORS

IO-Link Technical specifications
Sensors

Photoelectric Sensors
Fiber-optic Sensors

Type

Ultra small type

Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

Model no. (note 1)

NPN output PNP output

Fork width

Object to be sensed

Repeatability

Supply voltage

Output

Output operation

Response time

Ambient temperature Protection

PM-p25(-R) (note 2) PM-p25P

Small type With cable
PMp45 PMp45P 6mm (fix) 0.8 x 1.2mm (opaque) 0.01mm 5 to 24V DC ±10% PNP / NPN open-collector transistor, max. 50mA Incorporated with 2 outputs: Light-ON / Dark-ON Under light incident condition: max. 20s Under light interrupted condition: max. 80s (Response frequency: min. 3kHz) -25 to +55°C IP64 (IEC)

PM-25/45/65

Emitting element Connection method

Cable, 1m

Notes: 1.) K = K type
L = L type F = F type R = R type U = U type T = T type Y = Y type 2.) Suffic -R = bending-resistant cable 3.) Cable not included in delivery, please order separately (accessories, page 129)

Infrared LED

Built-in connector PM-p65 PM-p65P
IP40 (IEC) Connector (note 3)

31

Features
 Stable detection by convergent reflective mode
The stable detection characteristics of the PM2 series are obtained since it is a convergent reflective type and senses a limited area. Thus regardless of the background, stable detection is possible.

Object to be sensed

30mm

Background

PM2
Convergent reflection sensing ensures stable detection

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors

Safety Sensors

 Not affected by background
Even a specular background does not affect the sensing performance if the sensor is located 30mm away from it (when directly opposite).

Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

 Dark object detectable

Since the sensor is very sensitive, it can detect even a dark

object of low reflectivity.

PM2

 Object to be sensed
A 0.05mm copper wire can be detected at a distance of 5mm.

Typical applications
Minute object detectable

Starting point and overrun is sensed using the dog on the base
Overrun sensing Dog

Detecting capacitors in tray
The convergent reflective type sensor reliably detects capacitors in a tray without being affected by their color, characters, marks or glossiness.
PM2-LH10-C1

Overrun sensing

Start point sensing

32 PHOTOELECTRIC SENSORS / MINIATURE SENSORS

IO-Link Technical specifications
Sensors

Photoelectric Sensors

Type

Fiber-optic Sensors

Standard Fibers

Top sensing

Fiber Sensors Communication
Units

Mark Sensors Laser Sensors

Front sensing

Connector type

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

L type (Top sensing) Top sensing

Cable type

Front sensing PM2

L type (Top sensing)

Image

Model no. PM2-LH10 PM2-LH10B PM2-LF10 PM2-LF10B PM2-LL10 PM2-LL10B PM2-LH10-C1 PM2-LH10B-C1 PM2-LF10-C1 PM2-LF10B-C1 PM2-LL10-C1 PM2-LL10B-C1

Type

Model no.

Light-ON Dark-ON

Top sensing PM2-LH10 PM2-LH10B

Connector type Front sensing
PM2-LF10 PM2-LF10B

L type (Top sensing)
PM2-LL10
PM2-LL10B

Top sensing PM2-LH10-C1 PM2-LH10B-C1

Cable type Front sensing PM2-LF10-C1 PM2-LF10B-C1

Sensing range

2.5 to 8mm (conv. point: 5mm) with white non-glossy paper (15x15mm)

Object to be sensed
Repeatability (perpendicular to sensing axis)
Supply voltage

Min. Ø 0.05mm copper wire (setting distance: 5mm) 0.08mm
5 to 24VDC ± 10%

Output

NPN open-collector transistor, max. 50mA

Response time

Max. 0.8ms

Emitting element

Infrared LED

Connection method

Connector for soldering (note)

Note: Cable is not included in delivery. Please select under accessories (page 129)

Cable, 1m

L type (Top sensing) PM2-LL10-C1
PM2-LL10B-C1

PHOTOELECTRIC SENSORS / TRIGONOMETRIC SENSORS

33

EQ-500
Long range sensing capability up to 2.5m

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors

Safety Sensors

Features
 Impervious to variations in color or angle
Due to its advanced optical system, the sensor is not affected by variations in the object's angle or gloss as compared to conventional sensors. Moreover, sensing can be performed at a somewhat constant distance even if the sensing object is black or white.
 Not affected by background objects
Due to the 2-segment photodiode adjustable range system, the sensor does not detect objects outside the preset sensing field. It will not malfunction even if someone walks behind the sensing object, or machines or conveyors ar in the background.
 An easy-to-set adjuster with indicator
Equipped with a 2-turn adjuster with indicator making it easy to set for short or long distances. EQ-500 series can function with 24 to 240V AC and 12 to 240V DC. Therefore, almost any power supply anywhere in the world will work.
 Equipped with BGS/FGS function
We have added a DC-voltage type with NPN and PNP transistor outputs, all in one sensor. Its BGS/FGS function controls any background effects for more stable sensing.

 Convenient timer function models
Types with an ON-delay/OFF-delay timer available. (EQ-5pT)
> Operation: ON-delay OFF-delay > Timer period: 0.1 to 5s (individual setting possible)

Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

 Little affected by contamination on lens
Even if the lens surface gets somewhat dirty from dust particles, EQ-500
there is very little change in the operation field, rendering stable and consistent detection even for particles appearing close to the front surface of the unit.

 Convenient terminal block type
Cabling is enabled by way of a terminal block.

Distance adjuster (2-turn)
ON delay timer adjuster

Display
OFF delay timer adjuster

Terminal block
Conduit connector

34 PHOTOELECTRIC SENSORS / TRIGONOMETRIC SENSORS

IO-Link Technical specifications
Sensors

Photoelectric Sensors
Fiber-optic Sensors

Type

Multi-voltage type With timer

With timer

DC-voltage With timer

With timer

Standard Fibers

Model no.

EQ-501

EQ-501T

EQ-502

EQ-502T

EQ-511

EQ-511T

EQ-512

EQ-512T

Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors

Sensing range Supply voltage Output
Output operation Response time
Timer periods
Protection Ambient temperature

0.2 to 2.5m

0.2 to 1.0m

0.2 to 2.5m

0.2 to 1.0m

24 to 240VAC ±10%, or 12 to 240VDC ±10%

12 to 24VDC ±10%

Relay contact 1a 3A/250VAC

PNP / NPN open-collector transistor, max. 100mA

Light-ON or Dark-ON

Max. 20ms (for EQ-50pT dependent on the setting timer period)

Max. 20ms (for EQ-51pT dependent on the setting timer period)

Incorporated with

Incorporated with

Incorporated with

Incorporated with

variable

variable

variable

variable

­

ON-delay /

­

ON-delay /

­

ON-delay /

­

ON-delay /

OFF-delay timer

OFF-delay timer

OFF-delay timer

OFF-delay timer

(0.1 to 5s)

(0.1 to 5s)

(0.1 to 5s)

(0.1 to 5s)

IP67 (IEC)

­20 to +55°C

Accessories

Emitting element

Infrared LED

EQ-500

Connection method Dimensions (HxWxD)

Convenient terminal block 68x26x68mm

Accessories

Screwdriver, 1 pc.

35

Features
 Not affected by object color or background  Long sensing range 2m  Compact size
The EQ-30 saves space since a miniaturized housing of 68x20x40mm (HxWxD) has been designed.
 Plug-in connector type
The plug-in connector type (M12) of the EQ-30 series can be easily disconnected for replacement.
Typical applications

EQ-30
Unaffected by color or material, 2m distance adjustable fixed-focus sensing

Technical specifications

Type

Diffuse

Model no.

NPN output PNP output

EQ-34 (J) (note) EQ-34PN (J)

Rated sensing distance

2.0m

Sensing range

0.1-2m

Detectable target

Transparent and opaque material

Hysteresis

Max. 10% of measurement

Response time

Max. 2ms

Supply voltage

10 to 30VDC ± 10%

Output

PNP / NPN open-collector transistor, max. 100mA

Emitting element
Rated current consumption without load
Material

Infrared LED
NPN type: 50mA PNP type: 55mA
Plastic

Protection

IP67 (IEC)

Ambient temperature

­20 to +55°C

Connection method

Cable 2m or M12 connector

Dimensions (HxWxD)

68x20x40mm

Accessories Note: Suffix J = M12 connector type

Screwdriver, 1 pc.

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
EQ-30

Long distance sensing

Object detection

Color-independent detection

36 PHOTOELECTRIC SENSORS / AREA SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors

 Letters, postcards can be detected
Thin objects can be detected by using the cross-beam scanning system.

Accessories NA1-11

 Beam pitch: 10mm
Object to be sensed size of ø13.5mm is realized by using a beam pitch of 10mm.

Scanning Non-scanning

Cross-beam scanning system

1 2 3 4 5 6 7 8 9 0 A
Emitter

1 2 3 4 5 6 7 8 9 0 A
Receiver

NA1-11
Cross-beam scanning system to detect slim objects
 Long sensing range
Though very slim, a wide sensing area of 1m length and 100mm width is realized. It is most suitable for object detection on a wide assembly line or for detecting the dropping of or incursion by small objects whose travel path is uncertain.
 Clearly visible large indicator
A clearly visible large indicator having a 55mm width is incorporated on both the emitter and the receiver.
55mm

Typical applications
Detecting postcards
NA1-11 can detect thin postcards due to its crossbeam scanning system.

Detection of haphazardly falling objects

NA1-11

PHOTOELECTRIC SENSORS / AREA SENSORS

Technical specifications

Type

NPN

PNP

Model no.

NA1-11

NA1-11-PN

Sensing height

100mm

Sensing range

0 to 1m (note)

Beam pitch

10mm

Numbers of beam channels

11 each on the emitter and the receiver, respectively

Object to be sensed

Min. ø 13.5mm (opaque)

Supply voltage

12 to 24VDC ± 10%

Output

NPN open-collector transistor, max. 100mA

PNP open-collector transistor, max. 100mA

Ambient temperature

­10 to +55°C

Connection method

Cable, 2m

Dimensions (HxWxD) Note: Operating range for the receiver: 0.17 to 1m

140x30x10mm

37
IO-Link Sensors Photoelectric Sensors Fiber-optic Sensors
Standard Fibers Fiber Sensors Communication Units Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors Accessories
NA1-11

38 PHOTOELECTRIC SENSORS / AREA SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors

 10mm thick: half the thickness of conventional models
Space saving now possible; ultra-thin design does not obstruct picking operations.

Accessories

NA1-PK5/ NA1-PK3
Pick-to-light sensor ­ Ultra-slim body
 Two unit installations are possible
Sensor units can now be set to different light emission frequencies in order to prevent mutual interference. Two units can now be operated in a side-by-side configuration without interference for problem-free detection over wide areas.

NA1-PK5/ NA1-PK3

Cable can be freely arranged in any position

 Lighting pattern selectable
The job indicator operation can be selected as either continuous lighting or blinking.

 Selectable detection operation
Sensor units can be set to detect the interruption of 1 beam channel or 2 or more beam channels.

Continuous lighting

Blinking

Single beam interruption

Double beam interruption

Changeover

Changeover

All opaque bodies with ø35mm or greater will be detected.

The accidental passage of small objects through the beam axis will not trigger detection, yet the operator's hands will always be accurately detected. This function is also useful when small objects regularly interrupt the beam axis.

39

Typical applications
Cell production line

Assembly line

Technical specifications

Type Model no. Sensing height Sensing range Beam pitch Number of beam channels Object to be sensed Supply voltage Output Connection method Dimensions (HxWxD)

NPN

PNP

NA1-PK5

NA1-PK3

NA1-PK5-PN

NA1-PK3-PN

100mm

49.2mm

100mm

49.2mm

0.1 to 1.2m

0.03 to 0.3m

0.1 to 1.2m

0.03 to 0.3m

25mm

24.6mm

25mm

24.6mm

5 beam channels

3 beam channels

5 beam channels

3 beam channels

Min. ø 35mm (opaque)

Min. ø 29mm (opaque)

Min. ø 35mm (opaque)

Min. ø 29mm (opaque)

12 to 24VDC ± 10%

NPN open-collector transistor max.100mA

PNP open-collector transistor max.100mA

Cable, 2m

140x30x10mm

70x24x8mm

140x30x10mm

70x24x8mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
NA1-PK5/ NA1-PK3

40 FIBER-OPTIC SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

FX-100
Excellent price/performance ratio

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Easy to read
The digital dual display allows you to check both the threshold value and incident light intensity at the same time. It also makes the procedures for setting the various values much easier.

 Multipurpose M8 connector type
The connectors used are commercially available M8 connecFX-100 tors, so that processing costs and lead time required for carry-
ing out processing can be greatly reduced.

 Designed in a 3-layer structure to accomodate basic through advanced settings
Setting details are divided into three levels for clearer operation, so that settings for normal operation are made in 'RUN mode', basic settings are made in 'SET mode', and advanced functions are set in 'PRO mode'. This makes setting operations much easier to understand and carry out.

Typical applications
Wafer detection Detects wafer carrier cases through vacuum chamber´s view port.

Wafer detection Sensing possible in corrosive environment. Lenses at the ends of the fiber heads expand the sensing range.

Wafer carrier case

Wafer

Thru-beam type chemicalresistant fiber FT-L8Y

41

Detection of breaks / cracks of glass

Detection over long ranges

FV-SV2

FT-H30-M1V-S

Detection of glass substrate in vacuum chamber

Detection of glass substrate

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors

Laser Sensors

Technical specifications

Standard type

Long sensing range

Type

Connector type

Cable type

Connector type

Cable type

Model no.

NPN output PNP output

FX-101 (-Z) (note 2) FX-101P (-Z) (note 2)

FX-101-CC2 FX-101P-CC2

FX-102 (-Z) (note 2) FX-102P (-Z) (note 2)

FX-102-CC2 FX-102P-CC2

Supply voltage Power consumption Response time Output

Response time 0: Response time 1: Response time 2: Response time 3:

12 to 24VDC ±10%

Normal operation: max. 720mW (current consumption max. 30mA at 24V supply voltage) Eco mode: max. 600mW (current consumption max. 25mA at 24V supply voltage)

max. 250µs max. 450µs max. 500µs max. 600µs

Response time 1: Response time 2: Response time 3: Response time 4:

max. 2.5ms max. 2.8ms max. 3.2ms max. 5.0ms

PNP / NPN open-collector transistor, max. 100mA

Output operation

Selectable either Light-ON or Dark-ON

Short-circuit protection

Incorporated

Sensitivity setting

2-level teaching/Limit teaching/Full-auto teaching

Digital display Timer function Interference prevention Ambient temperature Emitting element

4 digit green + 4 digit red LCD display

ON-delay /OFF-delay, switchable either effective or ineffective. [Timer period:1ms, 5ms, 10ms, 20ms, 40ms, 50ms, 100ms, 500ms, 1000ms]

Incorporated Selectable response time method (note 1)
(Functions at response time 1, 2 or 3)

Incorporated Selectable response time method (note 1) (Functions at response time 1, 2, 3 or 4)

­10 to +55°C (if 4 to 7 units are mounted close together: ­10 to +50°C; if 8 to 16 units are mounted close together: -10 to +45°C (no dew condensation or icing allowed)

Red LED

Material

Enclosure: polycarbonate; key switch: polycarbonate; fiber lock lever: PBT

Connection method

Small connector M8 connector (note 3)

Cable, 2m

Small connector M8 connector (note 3)

Cable, 2m

Dimensions (HxWxD)

32x9x66.4mm

Accessories

--

CN-14A-C2 (Connector attached cable: 2m): 1 pc.

--

CN-14A-C2 (Connector attached cable: 2m): 1 pc.

Notes: 1.) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to different frequency values.
However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z)/FX-101(P)-CC2 2.) Suffix -Z = M8 connector type 3.) The cable is not included in delivery. Please select under accessories (page 129)

Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
FX-100

42 FIBER-OPTIC SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 FX-301(P) (red LED type) version upgrade
We improved the standard model by enhancing its sensing stability and equipping it with handy functions such as the lightemitting amount selection function.

 Super high-speed response of 35µs
The FX-301(P)-HS model is the digital type fiber sensor realizing FX-301 a super high-speed response of 35µs rendering it capable of
sensing minute objects moving at high speeds.

 Stable sensing over long and short periods
In addition to a four-chemical emitting element which suppresses changes in the light-emitting element over time so that a stable level of light emission can be maintained over long periods, a new APC (Auto Power Control) circuit has also been adopted. Because fluctuations over short periods of time have also been suppressed, stable sensing is possible very quickly once the power is turned back on after setup changes.

FX-301
Enhanced functions - strong performance
- easy to use

 Sensing range has been greatly increased
All models use a double coupling lens that enables a much wider sensing range and maximization in the light emission efficiency. Sensing ranges with small diameter fibers and ultra small diameter fibers, which have become very popular due to the miniaturization of chip components, have been increased by 50% over previous values achieved with other amplifiers.

FX-301 series double coupling lens

Conventional fiber sensors (no lens)

Light-emitting amount

Stable sensing comparison
Short-term stability Deviation

FX-301(P)(-HS)
Three-chemical emitting element

Long-term stability Time

43

Typical applications

Workpiece detection
This standard type of FX-301(P)(-HS) using red light has a four-chemical emitting element for stable sensing over long periods.

Sensing translucent stickers
The blue LED type greatly reduces the damping rate, making it ideal for delicate sensing for yellow/red transitions.

Object sensing during the painting process
Due to a sensing range of 19.5m (FX-301 long range mode) and a 10m fiber length, it can be lead through rough environments freely.

Engine block passage confirmation
FD-WKZ1 has realized a sensing range of 480mm (FX-301 long range mode). In addition, due to its powerful beam, it can even work in adverse environments such as in areas prone to dust.
Engine block

Register mark detection
The green LED type greatly reduces the damping rate, making it ideal for delicate sensing.

Sensing film meandering
Infrared LED type is ideal for sensing environments with light restrictions, such as places where lightsensitive film is being handled.

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors

Laser Sensors

Wire breakage detection
Wide beams are ideal for moving wire detection.

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

FT-A11

FX-301

Technical specifications

Type

Standard type

High speed

Model no.

NPN output PNP output

FX-301( /-B/-G/-H) (note 1) FX-301( /-B/-G/-H)P

FX-301-HS FX-301P-HS

Supply voltage Response time Output

12 to 24VDC ±10%

Max. 65µs H-SP (Red LED type only); max. 150µs (FAST);
max. 250µs [STD/S-D (Red LED type only)]; max. 2ms (LONG) selectable with jog switch

Max. 35µs (H-SP); max. 150µs (FAST); max. 250µs (STD/S-D); max. 2ms (LONG) selectable with jog switch

PNP / NPN open-collector transistor, max. 100mA

Output operation Sensitivity setting Digital display Automatic interference prevention function Ambient temperature
Emitting element
Connection method

Selectable either Light-ON or Dark-ON, with jog switch
2-level teaching/Limit teaching/ Full-auto/ teaching
4-digit red LED display

Incorporated (Up to 4 sets of fiber heads can be mounted close together.) (However, H-SP mode is 2 sets.)

FX-301(P): Red LED, FX-301B(P): Blue LED, FX-301G(P): Green LED, FX-301H(P): Infrared LED

­10 to +55°C Connector (note 2)

Red LED

Dimensions (HxWxD)

30.5x10x64.5mm

Accessories

FX-MB1 Amplifier protection seal

Notes: 1.) Without suffix = Red LED
Suffix-B = Blue LED Suffix-G = Green LED Suffix-H = Infrared LED 2.) The cable for amplifier connection is not supplied as an accessory. Please select under accessories (page 129)

44 FIBER-OPTIC SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

FX-311
Remarkably easy to use

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 12-turn potentiometer with visible indicator
12-turn potentiometer has been incorporated for fine adjustments. It enables very fine differences to be detected. Since the potentiometer is illuminated, you can even make adjustments easily in dark areas.

 Three light source types (red, green, blue) are made

FX-311

available for expanding applications

Rapid blinking `assist function' eases adjustment for optimum sensitivity.

Typical applications
Detecting transparent PET bottles
The green LED type is ideal for stably sensing objects such as transparent bottles which yield only small amounts of light fluctuation.

Register mark detection
The blue LED type can accurately sense yellow marks on white backgrounds that are difficult to sense using the red LED type.

FX-311G

Technical specifications

Model no.

NPN output PNP output

FX-311 FX-311P

Supply voltage

12 to 24VDC ±10%

Power consumption

Max. 840mW (Current consumption max. 35mA at 24V supply voltage)

Response time

Max. 250µs (STD / S-D), max. 2ms (LONG) selectable with selection switch

Output

PNP / NPN open-collector transistor, max. 100mA

Output operation

Selectable either Light-ON or Dark-ON, with selection switch

Short-circuit protection

Incorporated

Operation of indicators

Orange LED (lights up when the output is ON)

Timer function Automatic interference prevention function Ambient temperature
Emitting element

Incorporated with OFF-delay timer, selectable either effective (approx. 10ms or 40ms) or ineffective
Incorporated (Up to 4 sets of fiber heads can be mounted closely.) (note 1) ­10 to +55°C (if 4 to 7 units are mounted close together: ­10 to +50°C;
if 8 to 16 units are mounted close together: ­10 to +45°C (no dew condensation or icing allowed) Red LED

Material

Enclosure: Heat-resistant ABS, Case cover: polycarbonate

Connection method

Connector (note 2)

Dimensions (HxWxD)

34.5x10x70.5mm

Notes: 1.) When the power supply is switched on, the light emission timing is automatically set for interference prevention 2.) The cable for amplifier connection is not supplied as an accessory. Please select under accessories (page 129)

45

Features
Optimized stability
When used with the super quality fiber as a set, the incident light intensity variation among units is decreased to only 1/4 of that of conventional models.

High performance
The FX-500 with its ultra high response time improves of 25s productivity.

Super quality fiber

FX-500 series

Threshold Incident light

value

intensity

Digital control is essentially achieved
Stability of the incident light intensity is by 4 times improved. Values stay close together even after replacing an amplifier.

FX-500/550
Fiber amplifier at the industry's leading edge

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors

HYPER mode incorporated
FX-500 in combination with the small diameter fiber can handle challenging detections over a super long sensing range.

Safety Sensors

Improved accuracy!
FX-500 with its accurate detection catches fractional difference in light intensity, fulfilling high precision and low-hysteresis applications.

Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

FX-500
Previous model

Max. 5.6 times!

FX-500/550 FT-A11

 No PLC necessary, saving material and programming costs
Logical operation of sensors

Detection fiber

Three logical calculations (AND/OR/ XOR) are selectable using Output 1 of multiple FX-500 series amplifiers. You can logically connect two outputs of an FX-500 or one input of a normal sensor to the output of an FX-500 sensor.

Synchronization fiber

 Analog output cable type FX-505

The sensor outputs an analog signal of 4-20mA in proportion to digital value displayed for the current light intensity received.

Edge tracking of film or sheet
Actual position Deviation

20

Calculation of 2 neighboring FX-500 amplifiers

Communication direction

Upper side Output 1 Calculation result output Lower side Output 2 Normal operation

Calculation of two outputs in one FX-500

FX-502(P) / 505(P)-C2

Output 1 Calculation result output Output 2 Normal operation
Calculation of one FX-500 and external input FX-502(P) / 505(P)-C2

External input setting (sensor, contact, PLC, etc.)
Output 1 Calculation result output

 Direct settings
Direct adjustment: Threshold values can be changed directly in RUN mode.

Direct adjustment

Direct teaching: Teaching can be done in RUN mode. Just press the SET button once for object "present" and "not present".

Direct teaching

Output current (mA)

4 0 Light intensity

4,000/8,000

Drifting path can be tracked as the light intensity changes.

46 FIBER-OPTIC SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors

Typical applications
Counting of IC pins
FT-H20W-M1

Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive Proximity
Sensors
Measurement Sensors

Glass substrate sensing

Ionizers/ Electrostatic
Sensors

Accessories

FX-500/550

Check crimping

Technical specifications

Type

Connector

Cable

Model no.

NPN output PNP output

FX-501 FX-501P

FX-502 FX-502P

FX-551 FX-551P

FX-551-C2 FX-551P-C2

FX-505-C2 FX-505P-C2

Digital fiber sensor amplifier

Digital

Analog

Timer function

Adjustable: 0.1ms to 999.9ms in 0.1ms steps, 1 to 9999ms in 1ms steps, 1 to 32s in 1s steps

Interference prevention
Response time Analog voltage output

Auto interference prevention function for up to 12 units and selectable emission frequency method
Max. 25s/60s/250s/2ms/4ms/24ms ­

Incorporated (up to 4 units) Max. 60µs/ 250µs /2ms /4ms /24ms

Auto interference prevention function for up to 12 units and selectable emission frequency method
Max. 25s/60s/250s/ 2ms/4ms/24ms
4 to 20mA

Supply voltage

12 to 24VDC ±10%

Output

PNP / NPN open-collector transistor, max. 100mA

Emitting element

Red LED

Material
Rated current consumption (without load)
Protection

Enclosure: polycarbonate, switch: POM
Normal operation: max. 40mA at 24V supply voltage Eco mode: max. 30mA at 24V supply voltage
IP40 (IEC)

Ambient temperature

­10 to +55°C

Connection method

Connector type (note)

Cable, 2m

Dimensions (HxWxD)

34x10x75mm

Accessories

FX-MB1 Amplifier protection seal

­

Note: The cable for amplifier FX-501p, FX-502p, FX-551p is not supplied as an accessory. Please select under accessories (page 129).

FX-MB1 Amplifier protection seal

Fiber-optic Sensors
Now with communication interface!

48 STANDARD FIBERS

IO-Link Fibers with integrated high-precision plug
Sensors

Photoelectric Sensors

Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors

 Stable light intensity
Optical fibers with insertion plug-in achieve a very high quality standard. Through the integrated high-precision plug, the fiber core can be centered to within ±40µm. Variation in light intensity could thus be reduced to ±10%.
 New fiber core
Now the core consists of only one fiber instead of several single fibers. This design improves sensing stability dramatically because there is no variation in light intensity among individual fibers.

Measurement Sensors

New Old

Ionizers/ Electrostatic
Sensors

Accessories

 Sharp bending and flexible fibers
With a bending radius of 4mm, the optical fibers easily cope with millions of bending cycles.

Fibers with integrated high-
precision plug

49

 Thru-beam type (one pair set)

Type

Shape of fiber head (mm)

Model no.

M3

M3 12

Tough FT-30

Bending radius
R2

Sensing range (mm)

Fiber cable length

FX-500 series

U-LG LONG FAST H-SP

STD

810

400

650

HYPR

210

1350

75

Threaded

M4

ø1.5

M4 15 ø1.5 10 ø3 10

Tough FT-40
Tough FT-S20
Tough FT-S30

STD

R4

HYPR

1200

2m

(note) 3600

STD

R2

400 HYPR

1350

STD

R4

HYPR

1200

(note) 3600

2200 1700 530 190
810 650 210 75
2200 1700
30 190

Cylindrical

ø3

Note: The length of the fiber cable affects the sensing range.

 Reflective type

Threaded

Type

Shape of fiber head (mm)

Model no.

Bending Fiber cable

radius

length

Sensing range (mm) (note)

FX-500 series

U-LG LONG FAST H-SP

M3

M4

M3 12
M4 14
M6 17
ø3 10

Tough

FD-30

STD

330

R2
Tough

160 HYPR
600

250 80 25

FD-40

2m

Tough

STD

900

FD-60

520

740

HYPR

260

1550

90

R4

Tough

STD

330

FD-S30

160

250

HYPR

80

600

25

M6

ø3

Cylindrical

Note: The sensing range is specified for white, matt paper.

Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

FX-101 FX-102
135 400
320 870
135 400
320 870
FX-101 FX-102

Beam axis dia. (mm)

Protection

Ambient temperature

ø0.5

ø1

IP67 (IEC)

­55 to +80°C

ø0.5

ø1

Protection

Ambient temperature

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

45 155
IP67 (IEC) 140 420
45 155

­55 to +80°C

Fibers with integrated highprecision plug

50 STANDARD FIBERS

IO-Link Sensors
Photoelectric Sensors

Threaded fibers
 Thru-beam type (one pair set)

Fiber-optic Sensors
Standard Fibers

Type

Shape of fiber head (mm)

Model no.

Bending Fiber cable

radius

length

Sensing range (mm) (note 1)

FX-500 series

U-LG LONG FAST H-SP

Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

Threaded

M14

M4

M4

M3

Elbow

M3 12

Tough FT-31

Lens mountable: FX-LE1,

FX-LE2, FX-SV1

M4

15

Lens mountable: FX-LE1,

FX-LE2,

15

M4
Lens mountable: FX-LE1, FX-LE2, FX-SV1
M4
W7 × H9 × D13.5

With expansion lens M14
40

FT-43 Tough
FT-R40
FT-R43
Tough FT-140

STD

R2

315 HYPR

1350

STD

R4

HYPR

1400

(note 2) 3600

2m

STD

R4

930 HYPR

(note 2) 3600

STD

R4

720 HYPR

3000

R4

10m

STD
(note 2)
HYPR
(note 2)

19600 19600

770 550 210 70
2800 2100 770 240
1750 1500 500 160
1600 1100 430 130
19600 (note 2) 19600 (note 2)
16000 6300

Long sensing range Square head

Threaded fibers

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range
Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

 Reflective type

Type

Shape of fiber head (mm)

Model no.

M3
Ultra-small diameter

M3
12 Coaxial · Lens mountable: FX-MR3, FX-MR6
M3
17 Lens mountable: FX-MR3, FX-MR6, Coaxial
M3
16
M4
14 Lens mountable: FX-MR1, FX-MR2, FX-MR3, FX-MR5, FX-MR6, Coaxial
M4

Tough FD-31
Tough FD-32G
FD-EG30
Tough FD-41
Tough FD-42G

25 M6
17 Coaxial M6
17 15
M6

Tough FD-61
Tough FD-61G
Tough FD-R60

M6 Elbow

Bending radius
R2

Fiber cable length

Sensing range (mm) (note 1, 2)

FX-500 series

U-LG LONG FAST H-SP

STD

290

125

220

HYPR

80

515

25

2m STD

380

R2

200 HYPR

270 95

650

27

STD

130

R4

500mm

48 HYPR

110 30

170

9

STD

290

R2

125 HYPR

220 80

515

25

STD

380

R2

200 HYPR

270 95

650

27

2m

STD

840

R4

450 HYPR

670 200

1400

70

STD

800

R4

420 HYPR

650 200

1100

60

STD

600

R4

290

2m

HYPR

550 190

1100

65

Threaded M4

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The sensing range is specified for white, matt paper

Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

FX-101

Beam axis dia. (mm)

Protection

FX-102

Ambient temperature

130 340

ø0.5

350 970

ø1.5

­55 to +80°C

270

740

IP67 (IEC)

ø1
210 640

14000

19600

ø10

(note 2)

­40 to +70°C

FX-101 FX-102

Protection

Ambient temperature

35 140

IP67 (IEC)

70 190
IP40 (IEC)
20 70

­55 to +80°C ­40 to +70°C

35 140

IP67 (IEC)

70 190

IP40 (IEC)

120 410

IP67 (IEC)

120 350

IP40 (IEC)

110 240

IP67 (IEC)

­55 to +80°C

51

Square head fibers

 Thru-beam type (one pair set)

Type Shape of fiber head (mm)

Model no.

M3

M3 W5.5xH8xD16
M4 W7xH9xD13.9

Tough FT-R31
FT-R41W

With lens M4
W7xH9xD14.4
Lens mountable: FX-LE1/FX-LE2/FX-SV1
M4
W7xH9xD13.5

FT-R42W
Tough FT-R43

M4

Square head

Bending radius
R2
R1

Fiber cable length

Sensing range (mm) (note 1)

FX-500 series

U-LG LONG FAST H-SP

STD

580

270

440

HYPR

160

1000

55

STD 800
HYPR

3200

1800 1400 460 150

STD
HYPR
(note 2)

2200 3600

3600 (note 2) 3500 1300 460

2m

STD

720

HYPR

3000

1600 1100 430 130

Cable protection Usable with lens

Tough

FT-R44Y

R4

W7xH9.5xD15.5 Full protection

Tough FT-R60Y

W10xH11xD21.2

STD 720
HYPR

3000

STD
HYPR
(note 2)

2100 3600

M6

Notes: 1.) The sensing range of the free-cut type fiber may be reduced by 20% depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range 3.) The fiber cable is oil-resistant

1600 1100 430 130
3600 (note 2) 3600 (note 2)
1260 400

FX-101 FX-102
100 340
250 710
510 2000
210 640
210 640
690 1890

Beam axis ø (mm)

Protection

Ambient temperature

ø0.5

IP67 (IEC) ­55 to +80°C

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors

ø1 ø2.2 ø1 ø1

IP40 (IEC) ­40 to +60°C

Laser Sensors Safety Sensors

IP67 (IEC) ­55 to +80°C

IP67 (IEC) (note 3)

­55 to +80°C

Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

ø3.5

IP68G

­55 to +80°C

Square head fibers

 Reflective type

Type Shape of fiber head (mm)

Model no.

Coaxial, lens mountable M3
W5.5×H8×D16 Coaxial, lens mountable
M3
W5.5×H8×D16 Coaxial, lens mountable
M3
W5.5×H8×D16 Coaxial, lens mountable
M3
W5.5×H8×D16

Tough FD-R31G
FD-R32EG
FT-R34EG
FD-R33EG

Bending radius
R2

Fiber cable length

Sensing range (mm) (note 1, 2)

FX-500 series

U-LG LONG FAST H-SP

STD

310

170

260

2m

HYPR

85

530

27

STD

110

45

92

HYPR

30

170

9

STD

90

R4

500mm

38 HYPR

70 23

130

7

STD

44

19

33

HYPR

11

84

3

Square head M3

M4

M4

Tough

STD

430

FD-R41

R2

210 HYPR

320 100

W7×H9×D13.5

710

34

M6

Cable protection

Tough

2m

TD

610

FD-R61Y

R4

280 HYPR

435 160

W10xH11xD15.5

990

50

Notes: 1.) The sensing range of the free-cut type fiber may be reduced by 20% depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range 3.) The fiber cable is oil-resistant

Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

FX-101 FX-102
45 150
20 68
17 60
7 22
60 170
85 185

Beam axis ø (mm)

Degree of protection

Ambient temperature

Emitter ø0.5

­55 to +80°C

Emitter ø0.25
Emitter ø0.175

IP40

­40 to +70°C

Emitter ø0.125

­20 to +60°C

ø0.75 ­

IP67
IP67 (note 3)

­55 to +80°C

52 STANDARD FIBERS

IO-Link Sensors
Photoelectric Sensors

Cylindrical fibers
 Thru-beam type (one pair set)

Fiber-optic Sensors
Standard Fibers

Type

Shape of fiber head (mm)

Model no.

Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

ø1

ø1 6
ø 1.5 10

Tough FT-S11
Tough FT-S21

ø1.5

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors Measurement
Sensors Ionizers/ Electrostatic Sensors
Accessories
Cylindrical fibers

Cylinder

Ultra-small diameter

ø3

ø2.5

ø3

ø 1.5

10

With lens, long sensing

range

ø2.5

8 ø3

10

ø0.25 ø3 5 15

ø0.4 ø3 5 15

FT-S21W
FT-S32
FT-S31W Tough
FT-E13 Tough
FT-E23

Bending radius
R2
R1 R10 R1
R2

Fiber cable length 500mm
2m
1m

Sensing range (mm) (note 1)

FX-500 series

U-LG LONG FAST H-SP

STD 90 HYPR
350

STD 315
HYPR

1350

STD 260
HYPR 990

STD
HYPR
(note 2)

3100 3600

STD 800
HYPR
STD 15 HYPR 52

3300

210 160 60 19
770 550 210 70
590 440 150 53
3600 (note 2) 3600 (note 2)
1800 600
1900 1400 490 160
30 24 8 2

STD

160

75

125

HYPR

42

270

13

Side sensing

ø4

ø4 3
25

Tough FT-V40

STD

R4

2m

HYPR

3500

(note 2) 3600

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range

3600 (note 2) 3600 (note 2)
2400 850

 Reflective type

FX-101 FX-102
40 90
130 340
80 240
1100 3000
260 720
6 19
22 80
1000 3100

Beam axis dia. (mm)

Protection

Ambient temperature

ø0.25 ø0.5

IP67 (IEC)

­55 to +80°C

­40 to +60°C

ø2

IP40 (IEC)

­40 to +70°C

ø1

­40 to +60°C

ø0.125 ø0.25

IP67 (IEC)

­40 to +70°C

ø2.5

IP50 (IEC)

­40 to +60°C

Sensing range (mm) (note 1, 2)

Type

Shape of fiber head (mm)

Model no.

Bending radius

Fiber cable length

FX-500 series

U-LG LONG FAST H-SP

ø1.5

ø3

Cylindrical

ø 1.5

Tough

STD

130

10

FD-S21

R2

1m

80 HYPR

190

110 37 11

ø3 15

Tough

FD-S32

R4

STD

790

420

660

HYPR

220

1200

75

ø3 15

FD-S32W

R1

STD

630

270

430

HYPR

150

900

45

ø3

Tough

STD

290

10

FD-S31

R2

125

2m

HYPR

220 80

515

25

Coaxial ø3 15

STD

340

FD-S33GW

R1

150 HYPR

280 90

670

25

Metal-free

NEW

Tough

STD

590

16

FD-S60Y

R4

320 HYPR

420 200

600

75

ø1.5 ø 0.48 15 3

FD-E13

STD

29

12

25

HYPR

7

50

2

ø3 ø 0.63 15 5

FD-E23

R4

1m STD

55

HYPR

170

120 80 30 9

ø5,5

ø1.5

Ultra-small diameter Oil-resistant

ø3

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The sensing range is specified for white, matt paper

FX-101 FX-102

Protection

25 70

IP40 (IEC)

120 345

80 230

IP67 (IEC)

35 140

45 140

IP40 (IEC)

140 300

IP68G

5 15
IP40 (IEC)
20 70

Ambient temperature
­55 to +80°C ­40 to +60°C ­55 to +80°C ­40 to +60°C ­40 to +70°C ­40 to +60°C

53

Fibers with sleeve

 Thru-beam type (one pair set)

Type

Shape of fiber head (mm)

Model no.

M3

Sleeve 40mm

M3

ø 0.88 10

Sleeve 40mm

M4

ø1.48 12

Tough FT-31S
Tough FT-42S

M4

Bending radius
R2
R4
(note 3)

Fiber cable length

Sensing range (mm) (note 1, 2)

FX-500 series

U-LG LONG FAST H-SP

STD

740

315

550

HYPR

195

1220

63

2m

STD

1130

HYPR

(note 2) 3600

2050 1600 530 190

Ultra-small

Tough

STD

160

ø 0.4 ø3 5 15

FT-E23

R2

75

1m

HYPR

270

125 42 13

Threaded

ø1 ø2 1,1
20 15

Tough FT-V23

STD

R4

450

2m

HYPR

1800

1000 880 280 90

ø2

Side sensing

ø1 ø2

Tough

STD

550

1

FT-V25

R2

240 HYPR

480 140

15 15

900

45

ø2.5

ø1,5 ø2,5 1,3
20 15

Tough

FT-V30

R4

STD 680
HYPR

2200

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range 3.) The bending radius of the sleeve is min. 10mm
Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

1200 1000 340 100

FX-101 FX-102

Beam axis dia. (mm)

Protection

130 340

ø0.5

300 800

ø1

IP67 (IEC)

22 80

ø0.25

160 400

ø0.75

95 260

ø0.5

IP30 (IEC)

180 480

ø1.0

Ambient temperature
­55 to +80°C
­40 to +70°C
­55 to +80°C

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
Fibers with sleeve

 Reflective type

Threaded M4

Ultra-small

diameter

Type

Shape of fiber head (mm)

Model no.

Ultra-small diameter
M3

Sleeve 15mm M3 ø0.8 15
Sleeve 40mm M4 ø1.48 12
Sleeve 40mm M6 15 ø 2.5 ø1.5 ø 0.48 15 3

FD-EG30S Tough
FD-41S Tough
FD-61S
FD-E13

M6

ø1.5

Bending radius
R4
R2
(note 3)
R4
(note 3)
R4

Fiber cable length

Sensing range (mm) (note 1, 2)

FX-500 series

U-LG LONG FAST H-SP

STD

110

1m

50 HYPR

80 30

170

9

STD

290

125

220

HYPR

80

515

25

2m

STD

790

420

660

HYPR

220

1200

75

STD

29

1m

12 HYPR

25 7

50

2

ø3

Cylindrical

Side sensing

15 15

Tough

ø3 ø1.5

2

FD-V30

R2

STD 65 2559
HYPR

130 120 35

240

14

15 20

Tough

2m

STD

220

ø5 ø2

2,3

FD-V50

R4

120 HYPR

210 75

370

25

ø5

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The sensing range is specified for white, matt paper 3.) The bending radius of the sleeve is min. 10mm
Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

FX-101 FX-102

Protection

Ambient temperature

20 70

IP40 (IEC) ­40 to +70°C

35 140
IP67 (IEC) ­55 to +80°C
130 360

5 15

IP40 (IEC) ­40 to +60°C

25 75
IP30 (IEC) ­55 to +80°C
40 100

54 STANDARD FIBERS

IO-Link Sensors
Photoelectric Sensors

Flat fibers
 Thru-beam type (one pair set)

Fiber-optic Sensors
Standard Fibers

Type

Shape of fiber head (mm)

Model no.

Fiber Sensors Communication
Units
Mark Sensors

Top sensing W3 × H8 × D12

Tough FT-Z30H

Laser Sensors

Top sensing W3 × H8 × D12

FT-Z30HW

Bending Fiber cable

radius

length

Sensing range (mm) (note 1)

FX-500 series

U-LG LONG FAST H-SP

R2

STD

3600 (note 2)

3500

3600 (note 2)

HYPR

2600

R1

(note 2) 3600

810

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors Measurement
Sensors Ionizers/ Electrostatic Sensors
Accessories
Flat fibers

Side sensing W3 × H12 × D8 Tough

FT-Z30E

R2

STD
HYPR
(note 2)

3.500 3600

Flat With boss

Side sensing W3 × H12 × D8

FT-Z30EW

R1

Front sensing W8.5 × H12 × D3

Tough

FT-Z30

R2

Front sensing W8,5 × H12 × D3

FT-Z30W

Front sensing W10 × H7 × D2

FT-Z20W

Top sensing

W2 × H10 × D10

FT-Z20HBW

R1

Front sensing W14 × H7 × D3.5

FT-Z40W

Top sensing W3.5 × H14 × D11

FT-Z40HBW

2m

STD

3400

HYPR

(note 2) 9600

STD
HYPR
(note 2)

2100 3600

STD
HYPR
(note 2)

1500 3600

STD 530
HYPR
(note 2)

1600

1m

STD

260

HYPR

1100

STD HYPR

1400 3500

2m

STD

800

HYPR

3300

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range

3600 (note 2) 3600 (note 2)
2400 740
3600 (note 2) 3600 (note 2)
2000 630
3600 (note 2) 3600 (note 2)
1200 410
3300 3200 1000 280
1100 900 330 100
670 570 180 55
3300 2300 890 290
1900 1400 490 160

 Reflective type

FX-101 FX-102

Beam axis dia. (mm)

Protection

Ambient temperature

1.400 3200

1200 3200
1400 2600

2×3 IP40 (IEC)

710 2300
ø2
540 1800

­40 to +60°C

230 670

ø1.5

­

100 320

ø0.5 IP67 (IEC)

330 1000

ø1.5

­

260 720

ø1 IP67 (IEC)

Type

Shape of fiber head (mm)

Model no.

Front sensing W10 × H7 × D2
Top sensing W2 × H10 × D10
Front sensing W14 × H7 × D3.5
Top sensing
W3.5 × H14 × D11

FD-Z20W FD-Z20HBW
FD-Z40W FD-Z40HBW

Bending radius

Fiber cable length

Sensing range (mm) (note 1, 2)

FX-500 series

U-LG LONG FAST H-SP

STD 2 to 65
HYPR 1 to 230

1 to 110 1 to 85 3 to 35 5 to 13

1m

STD

2 to 85

HYPR

R1

1 to 340

STD

110

HYPR

430

2m

STD

260

HYPR

760

1 to 210 1 to 180 2 to 55 3 to 15
230 180 1.5 to 65 3 to 25
540 470 1 to 160 2 to 50

FX-101 Fx-102
2 to 20 1 to 70

Protection

Ambient temperature

­

2 to 30 1 to 90
1 to 55 160

IP67 (IEC) ­40 to +60°C
­

1 to 90 0.5 to 240

IP67 (IEC)

Flat With boss

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The sensing range is specified for white, matt paper
Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

55

Wide beam fibers

 Thru-beam type (one pair set)

Type

Shape of fiber head (mm)

Model no.

Sensing width 32mm
W5 × H69 × D20

Tough FT-A32

Sensing range (mm) (note 1)

Bending Fiber cable

radius

length

FX-500 series

U-LG LONG FAST H-SP

STD

3600 (note 2)

R2

(note 2) 3600 HYPR

3600 (note 2) 3600 (note 2)

(note 2) 3600

2100

Sensing width
32mm f W5 × H69 × D20

FT-A32W

R1

STD
(note 2)
HYPR
(note 2)

3600 3600

3600 (note 2) 3600 (note 2) 3600 (note 2)
3000

Wide beam

Sensing width 11mm
W4.2 × H31 × D13.5

Tough FT-A11

R2

STD (note 2) 3600
2m HYPR
(note 2) 3600

Sensing width 11mm
W4.2 × H31 × D13.5

FT-A11W

R1

STD
(note 2)
HYPR
(note 2)

3600 3600

Array

Sensing width 5.5mm
W5 × H15 × D15

Tough FT-AL05

R2

STD 860
HYPR 2300

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range

3600 (note 2) 3600 (note 2) 3600 (note 2)
1100
3600 (note 2) 3600 (note 2) 3600 (note 2)
1300
1550 1500
50 170

FX-101 FX-102

Beam axis dia.
(mm)

Protection

Ambient temperature

3600 (note 2)
3600 (note 2)

3.2 × 32

­40 to +60°C ­40 to +55°C

1900 3600 (note 2)

IP40 (IEC) 2.2 × 11

­40 to +70°C

1700 3400

­40 to +55°C

250

0.25 ×

660

5.5

­55 to +80°C

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
Wide beam fibers

 Reflective type

Type

Shape of fiber head (mm)

Model no.

Bending Fiber cable

radius

length

Sensing range (mm) (note 1, 2)

FX-500 series

U-LG LONG FAST H-SP

Wide beam

Tough

STD

200

W7 × H15 × D30

FD-A16

R4

200 HYPR

200 140

cannot use

75

2m

Tough

STD

530

W5 × H20 × D20

FD-AL11

R2

320 HYPR

510 180

670

50

Array

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The sensing range is specified for white, matt paper

Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

FX-101 FX-102
120 240
100 285

Protection Ambient temperature

IP40 (IEC)

­40 to +60°C

­55 to +80°C

56 STANDARD FIBERS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors Measurement
Sensors Ionizers/ Electrostatic Sensors
Accessories
Convergent reflective fibers

Convergent reflective fibers for glass detection

 Reflective type

Ultra-small

Type

Shape of fiber head (mm)

Model no.

Glas substrate detection

Side sensing
W25 × H7.3 × D30 Long sensing range
W20 × H29 × D3.8 Long sensing range
W23.5 × H29 × D4.5 Long sensing range
W17 × H29 × D3.8 Short sensing range
W18 × H29 × D3.8 Short sensing range
W12 × H19 × D3 Short sensing range
W12 × H19 × D3
W24 × H21 × D4

FD-L32H
Tough FD-L30A
Tough FD-L31A
Tough FD-L22A
Tough FD-L23
Tough FD-L11
Tough FD-L10
Tough FD-L21

W24 × H21 × D4 W6 × H18 × D14

FD-L21W
Tough FD-L20H

W7.2 × H7.5 × D2

FD-L12W

Bending radius
R4 R2 R4
R2
R4
R2 R1 R2 R1

Fiber cable length

Sensing range (mm) (note 1, 2)

FX-500 series

U-LG LONG FAST H-SP

STD

0 to 56

4m

HYPR

0 to 110

0 to 87 0 to 74 1 to 38 Cannot use

STD HYPR

0 to 43 0 to 43

0 to 43 0 to 43 0 to 42 0 to 29

3m

STD

4 to 33

HYPR

3 to 35

STD

0 to 24

2m

HYPR

0 to 31

STD

0 to 29

3m

HYPR

0 to 30

STD 0 to 9.5
HYPR 0 to 11.5

STD 0 to 5 HYPR 0 to 6

STD

1.5 to 16

2m

HYPR

1 to 19

STD 3 to 14
HYPR 1.5 to 15

STD 23
HYPR 45

STD

8

1m

HYPR

14

4 to 33 4 to 33 4 to 32 5 to 25
0 to 28 0 to 27 0 to 24 0 to 18
0 to 30 0 to 30 0 to 28 1.5 to 24
0 to 10.5 0 to 10 0 to 9 0 to 8
0 to 5.5 0 to 5.5 0 to 4.5 0 to 4
1 to 18 1 to 18 2 to 15 3 to 12
2 to 15 2 to 15 4 to 14 6.5 to 10
35 32 2 to 15 5 to 9
12,5 12 0.5 to 7 0.5 to 4

FX-101 FX-102

Protection

Ambient temperature

16 to 30 0 to 50

­40 to +60°C

0 to 40 0 to 50

5 to 30 4 to 33

0 to +70°C

0 to 19 0 to 25

0 to 28 0 to 30
0 to 8 0 to 9

­20 to +70°C IP40 (IEC)

0 to 4.5 0 to 5.5
3 to 15 1.5 to 16

­40 to +60°C

7 to 12 3 to 14

5 to 15 1 to 30

­40 to +70°C

1 to 4.5 0.5 to 7

IP30 (IEC) ­40 to +60°C

Notes: 1.) The sensing range specified for transparent glass 100×100×0.7mm (FD-L32H: edge, FD-L21 and FD-L21W: t2mm). (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100×100x2mm) 2.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut

 Retroreflective type

Type

Shape of fiber head (mm)

Model no.

With polarizing filter

Side sensing

W5.2 × H9.5 × D16
W30 × H30 × D0.5 W7.5 × H2.2 × D11.2

FR-Z50HW Tough

FR-KZ22E

W4 × H2 × D21.5 W5.2 × H9.5 × D21
W10.6 × H28 × D10.1 W9.5 × H25 × D5.2
W28 × H10.6 × D10.1

Tough FR-KZ50H
Tough FR-KZ50E

Bending radius
R1

Fiber cable length

Sensing range (mm) (note 1, 2)

FX-500 series

STD HYPR

100 to 990 100 to 1900

U-LG LONG FAST H-SP
100 to 1400 100 to 1200 100 to 780 100 to 490

STD 15 to 310
HYPR 15 to 570
2m
R2
STD 20 to 300
HYPR 20 to 1000

15 to 460 15 to 410 15 to 220 15 to 100
20 to 800 20 to 400 20 to 200 20 to 200

FX-101 FX-102

Protection

Ambient temperature

100 to 550 100 to 830

IP40 (IEC)

­25 to +55°C

15 to 200 15 to 360
IP30 (IEC) ­40 to +60°C
20 to 200 20 to 350

Narrow view Side sensing Top sensing

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The sensing range is specified for the reflector
Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

57

Heat-resistant fibers

 Thru-beam type (one pair set)

Sensing range (mm) (note 1)

Type Temperature Shape of fiber head (mm)

Heat-resistant fiber

350°C 200°C 130°C

Lens mountable:

FX-LE1/LE2/SV1

M4

30
Lens mountable: FX-LE1/LE2/SV1
M4

23
Lens mountable: FX-LE2 M4

16

Model no.

Bending radius

Fiber cable length

FX-500 series

FT-H35-M2

R25

FT-H20W-M1

R10

FT-H13-FM2

R25

STD

2m

430 HYPR

1200

STD

1m

470 HYPR

(note 2) 1600

STD

700

2m

HYPR

3300

U-LG LONG FAST H-SP
880 670 250 80
1.000 840 300 90
1900 1300 410 140

Lens mountable: FX-LE1/LE2/SV1
M4 23

FT-H20-J20-S (note 5)
FT-H20-J30-S (note 5)

200mm (note 3)
300mm (note 3)

STD 470
HYPR

Heat-resistant (joint)

200°C

Side sensing

ø 3.8

24

ø4

FT-H20-J50-S (note 5)
FT-H20-VJ50-S (note 5)
FT-H20-VJ80-S (note 5)

Heat resistant R18
(note 4)

500mm (note 3)
800mm (note 3)

STD 600
HYPR

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range 3.) The fiber length of the heat-resistant side cannot be cut 4.) Bending radius R=25mm or more 5.) Heat-resistant side and ordinary temperature fiber are sold together as a set

1600 2100

1000 790 300 90
1300 980 390 120

FX-101 FX-102
170 490
100 300
250 700
135 420
150 500

Beam axis dia. (mm)
ø1.2 ø0.8 ø1.5
ø1.2

Ambient temperature ­60 to +350°C ­60 to +200°C ­60 to +130°C
­60 to +200°C

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
Heat-resistant fibers

 Reflective type

Sensing range (mm) (note 1, 2)

Type Temperature

Shape of fiber head (mm)

Threaded

350°C 200°C 130°C

Coaxial M6 25
Coaxial M6 28 M6
21

300°C

W19 × H27 × D5

250°C

W21 × H34.5 × D5

Model no.

Bending radius

Fiber cable length

FX-500 series

FD-H35-M2
FD-H20-M1
FD-H13-FM2 R25
FD-H30-L32
FD-H25-L45

STD

2m

260 HYPR

720

STD

1m

330 HYPR

840

STD

350

2m

HYPR

880

STD

2m

17 HYPR

40

STD

3m

5 to 42 HYPR

4 to 43.5

U-LG LONG FAST H-SP
540 460 150 45
550 500 200 55
640 600 200 65
30 25 12 1.5 to 6
4 to 43 4.5 to 43 5 to 40 6.5 to 34

FX-101 FX-102

Ambient temperature

75 280

­60 to +350°C

120 300

­60 to +200°C

100 280

­60 to +130°C

2 to 9 0 to 17

­60 to +300°C

7 to 35 7 to 38

­20 to +250°C
( ) Standard fibers ­20 to +70°C

Heat-resistant fiber Glass substrate detection convergent reflective

180°C

W19 × H27 × D5

FD-H18-L31

STD

16

2m

HYPR

60

32 24 13 2 to 6.5

0 to 10 0 to 25

Notes: 1.) The sensing range is specified for white, matt paper (50×50mm, glas substrate: FD-H30-L32, FD-H18-L31, clear glas 100×100×0.7mm: FD-H25-L43 and FD-H25-L45) 2.) The length of the fiber cable affects the sensing range

­60 to +180°C

58 STANDARD FIBERS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors Measurement
Sensors Ionizers/ Electrostatic Sensors
Accessories
Chemical/Vacuumresistant fibers

Chemical-resistant fibers
 Thru-beam type (one pair set)

Oil-resistant

Type

Shape of fiber head (mm) Model no.

M4

Square head

Cable-protection type Compatible with lens
W7×H9,5×D15,5 Side sensing
W10×H11×D21,2 SEMI W7 x H15 x D13

FT-R44Y FT-R60Y FT-Z802Y

M6

Bending Fiber caradius ble length

Sensing range (mm) (note 1)

FX-500 series

U-LG LONG FAST H-SP

STD 720
HYPR 3000
R4

STD

2100

HYPR

2m

(note 2) 3600

1600 1100 430 130
3600 3600 1.260 400

STD

3600 (note 2)

R25

HYPR

3100

3600 (note 2) 1900

(note 2) 3600

470

Chemical-resistant Flat

Cylindrical

Heat-resistant 115°C ø5.5
(25) ø5.5
(25)

FT-HL80Y FT-L80Y

Side sensing metal free ø5.5
(25)

FT-V80Y

STD
(note 2)
HYPR
(note 2)

3600 3600

STD

R30

(note 2) 3600

2m

HYPR

(note 3)

(note 2) 3600

STD 1300
HYPR (note 2) 3600

Notes: 1.) The sensing range of the free-cut type fiber may be reduced depending upon how the fiber is cut 2.) The length of the fiber cable affects the sensing range 3.) The allowable cutting range is 500mm from the end inserted at the amplifier 4.) The fiber is oil-resistant

3600 (note 2) 3600 (note 2)
2300 740
3600 (note 2) 3600 (note 2)
2800 920
2800 2200 800 240

FX-101 FX-102
210 640
690 1.890
520 3100
990 2340
1.100 2.600
340 800

Beam axis dia. (mm)
ø1 ø3,5
ø3.7
ø2.8

Protection IP67
(note 4)
IP68G

Ambient temperature
­55 bis +80°C
0 to +60°C ­40 to +115°C ­40 to +70°C

Vacuum-resistant fibers
 Thru-beam type (one pair set)

Type

Shape of fiber head (mm)

300°C Lens mountable: FV-LE1/SV2
M4
30

Model no.

Bending Fiber cable

radius

length

Sensing range (mm)

FX-500 series

U-LG LONG FAST H-SP

STD

590

FT-H30-M1V-S (note)

R18

1m

27 HYPR

470 160

1000

55

FX-101 FX-102

Beam axis dia. (mm)

Ambient temperature

110 280

ø1.2

­30 to +300°C

Vacuum-resistant Thru-beam type

Note: Sold as a set comprising vacuum type fiber and photo-terminal (FV-BR1)
 Reflective type

Convergent reflective

Type

Shape of fiber head (mm)

Model no.

Reflective type

300°C W9.5 × H5.2 × D15

FD-H30-KZ1V-S (note 1)

300°C, Glass substrate detection W19 × H5 × D27

FD-H30-L32V-S (note 1)

Bending Fiber cable

radius

length

Sensing range (mm) (note 2)

FX-500 series

U-LG LONG FAST H-SP

STD

1m

20 to 200 HYPR

5 to 500

R18

STD

3m

8 HYPR

18

10 to 340 15 to 270 20 to 120 20 to 45
12 10 5,5 1.5 to 3

Vacuum-resistant

Notes: 1.) Sold as a set comprising vacuum type fiber and photo-terminal (FV-BR1) 2.) The sensing range is specified for transparent glass 100×100×0.7mm

FX-101 FX-102

Ambient temperature

25 to 80 10 to 220
2.5 to 6.5 0 to 11

­30 to +300°C

59

Fibers for liquid leak/liquid detection

Type

Shape of fiber head (mm)

Model no.

Bending radius

Fiber cable length

Description

Protection

Ambient temperature

Heat resistant 125°C Fluorine resin coating
ø6

FD-F8Y

Protective tube R40
Standard fibers R15

2m (note)

ø6mm Protective tube: Fluorine resin, Length 1m (not cuttable) Liquid surface not contacted: beam received Liquid surface contacted: no beam received

IP68 (IEC) ­40 to +125°C

Contact type Liquid level sensing

Heat resistant 105°C Fluorine resin coating
ø4
Heat resistant 70°C Fluorine resin coating
ø4
SEMI S2 W20×H30×D10

FD-HF40Y FD-F41Y

Protective tube R20
Standard fibers
R10

ø4mm

Protective tube: Fluorine resin,

Length 500mm (not cuttable)

2m

Liquid surface not contacted: beam received

Liquid surface contacted: no beam received

Tough FD-F71

Protective tube

R20

Liquid leak detection

Standard fibers

Leak absent: beam received

R4

5m

Leak present: no beam received

­40 to +105°C IP67 (IEC) ­40 to +70°C
­20 to +60°C

Liquid leak detection

Pipe-mountable type Liquid level sensing

Default

W25 × H13 × D20

FD-F41

For wall thickness 1mm W25 × H13 × D20

FD-F4

R10

Applicable pipe diameter: Outer dia.: ø6mm to ø26mm Material: transparent pipe, PFA (fluorine resin, polycarbonate, acrylic, glass) Wall thickness: 1 to 3mm Liquid absent: beam received Liquid present: no beam received
Applicable pipe diameter: Outer dia.: ø6mm to ø26mm Material: transparent pipe, PFA (fluorine resin). Wall thickness: 1mm. Liquid absent: beam received Liquid present: no beam received

Liquid lsensing

Mountable on pipe W6.5 × H28.3 × D17

Tough FD-FA93

SEMI S2 W23 × H20 × D17

Tough FT-F93

2m

Applicable pipe diameter: Outer dia.: ø8mm or more

(When used with the tying bands: ø8mm to ø80mm)

R4

Material: transparent pipe, PFA (fluorine resin).

Liquid absent: beam received

Liquid present: no beam received

Protective tube R20
Standard fibers
R2

Applicable pipe diameter: Outer dia.: ø3mm to ø10mm Material: transparent pipe, PFA (fluorine resin). Wall thickness: 0.3 to 1mm Liquid absent: beam received Liquid present: no beam received

Note: The allowable cutting range is 500mm from the end inserted at the amplifier

Tough High flexibility: min. bending radius of 4mm, 10 mio. bending cycles (@ radius 10mm)

­

­40 to +100°C

­40 to +70°C IP40 (IEC)
­40 to +60°C

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
Fibers for liquid leak detection

Accessories
· RF-003 (Reflector for FR-KZ21/KZ21E) · RF-13 (Reflective tape for reflective type) · FX-CT1 (Fiber cutter) · FX-CT2 (Fiber cutter) · FX-CT3 (Fiber cutter) · FX-AT2 (Attachment for fixed-length fiber, Orange) · FX-AT3 (Attachment for ø2.2mm fiber, Clear orange) · FX-AT4 (Attachment for ø1mm fiber, Black) · FX-AT5 (Attachment for ø1.3mm fiber, Gray) · FX-AT6 (Attachment for ø1mm / ø1.3mm fiber, Black/Gray)

FX-CT3

FX-AT2

FX-AT3

RF-003

RF-13

FX-CT1

FX-AT4

FX-AT5

FX-CT2 FX-AT6

60 STANDARD FIBERS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors

Lens
 Thru-beam type fiber

Model no.

Picture

Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

FX-LE1

Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

FX-LE2 FX-SV1 FV-LE1

Description
Expansion lens increases the sensing range by 5 times or more, ambient temperature: -60 to +350°C (note 1, 2)
Expansion lens increases the sensing range by 6 times or more, ambient temperature: -60 to +350°C (note 1, 2)
Side-view lens, beam axis is bent by 90°, ambient temperature: -60 to +300°C (note 1, 2)
Expansion lens for vacuum fiber increases the sensing range by 4 times or more, ambient temperature: -60 to +350°C (note 1, 2)

FV-SV2 Lens

Vacuum resistant side-view lens, beam axis is bent by 90°, ambient temperature: -60 to +300°C (note 1, 2)

Notes: 1.) Consider the ambient temperature of the fibers to be used in combination 2.) Please test the functionality after mounting the lenses

Applicable fibers
FT-43, FT-42, FT-42W, FT-45X, FT-R40, FT-R43, FT-H35-M2, FT-H20W-M1, FT-H20-M1, FT-H20-J50-S,
FT-H20-J30-S, FT-H20-J20-S
FT-H30-M1V-S

 Reflective type fiber

Model no.

Picture

FX-MR1

Description
Pinpoint spot lens, distance to focal point 6±1mm, spot diameter Ø 0.5mm, ambient temperature -40 to +70°C (note 1, 2)

FX-MR2

Distance to focal point
Spot diameter

Zoom lens, screw-in depth (7-14mm), distance to focal point (18.5- 43mm), spot diameter Ø 0.7-2mm, ambient temperature: -40 to +60°C (note 1, 2)

FX-MR3

Distance to focal point
Spot diameter

Extremely fine spot, distance to focal point: 7.5±0.5mm, spot diameter: FD-EG31 Ø 0.15mm/ FD-EG30 Ø 0.3mm/ FD-42G, FD-42WG, FD-32G, FD-32GX Ø 0.5, ambient temperature: -40 to +70°C (note 1, 2)

Notes: 1.) Consider the ambient temperature of the fibers to be used in combination 2.) Please test the functionality after mounting the lenses

Applicable fibers FD-42G, FD-42GW FD-EG31, FD-EG30, FD-42G, FD-42GW, FD-32G, FD-32GX

FIBER SENSORS COMMUNICATION UNITS

61

Functions
 Function handy for startup and maintenance
Using a PLC or PC, this communication unit not only facilitates inputs (teaching, bank switching) to a digital fiber sensor e.g. FX-301(P), but also received-light amount and output status verifications greatly enhance workability during startup and maintenance.
 Intuitive integration at the controller level
Rapid integration at the controller level enables reliable monitoring, remote maintenance or remote control via open networks. Several units can be configured with minimal wiring efforts. Data can be saved centrally, where it can be archived or used for evaluation purposes.

IO-Link Sensors
Photoelectric
Communication Sensors Fiber-optic Sensors

units
Communications units for flexible solutions

Standard Fibers Fiber Sensors Communication Units Mark Sensors
Laser Sensors
Safety Sensors

 Combining different units
The ability to combine different sensor types, e.g. laser sensors, pressure sensors or digital fiber-optic sensors, opens up many application areas, especially for special purpose machinery manufacture. The sensors themselves communicate with each other via an infrared interface.

Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

FX-301; FX-305

SC-A01; SC-A02

FX-501; FX502

SC-G03-03

LS-501

DPS-401

LS-401

62 MARK SENSORS

Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

LX-100

Laser Sensors Safety Sensors

Introducing the 3-LED mark sensor

Pressure & Flow Sensors

Inductive Proximity
Sensors

Measurement Sensors Ionizers/
Electrostatic Sensors
Accessories
LX-100

Functions

 Equipped with 3 LEDs: red, green and blue

To detect any marking, this sensor is equipped with red, green and blue LED light emitting elements all in one. In addition, it uses a coaxial reflective optics system and realizes high precision sensing when used with a 1/4000 resolution 12-bit A/D converter.

Image schematic
Coaxial reflective and a sharp 1x5mm spot enable high precision sensing.

 2 selectable sensing modes for any application

Mark mode: This sensing mode automatically selects a single color from the 3 R-G-B LEDs

RED

GREEN

BLUE

to realize an ultra quick 45µs

response time. The automatic optimal LED selection function

Automatic selection

automatically selects the LED that

is most suitable for the sensing. This function is perfect for ultra

quick sensing.

Color mode: All 3 R-G-B LEDs light up and high precision mark color discrimination occurs using the R-G-B reflective light ratio. This function enables effective detection of films with patterns around the areas of the mark.

 Even beginners can quickly master MODE NAVI operation
The sensor's basic operations are represented by 6 indicator lamps (MODE NAVI). The user can check what mode the sensor is presently in with a quick glance rendering operation simple.
Sensing status digitally controllable
The sensing status, displayed numerically, can be verified at a glance. Also, the sensor settings for each type of packing film can be digitally indicated.
Direct codes enable settings verification at a glance
The settings for the LX-100 series sensors are displayed using a 4-digit direct code. Direct codes enable easy settings verification and maintenance by phone.
Super simple teaching
Teaching (setting the threshold value) is simple, even in "Mark Mode" or "Color Mode". In addition, because teaching via an operation panel or other external input device is also possible, models can be easily interchanged.
Compact design for significant space savings
Cable and plug-in connector types are available depending on the equipment used. These sensors can be easily integrated into already existing systems.

The color around letters is detected as a mark.

Predetermined colors are detected as marks.

Typical applications
Tube positioning
Detects printed marks to align tubes.

Mark detection
Mark detection of packaging film.

Technical specifications

Type

Cable

M12 plug-in connector type

Model no.

NPN output PNP output

LX-101 LX-101-P

LX-101-Z (note 1) LX-101-P-Z

Sensing range

10±3mm

Power supply Output
Output operation Response time Sensitivity setting Protection

12 to 24VDC ±10%

2 x NPN or 2 x PNP open-collector transistor; max. 50mA

1 x NPN or 1 x PNP open-collector transistor; max. 100mA

Mark mode: Light-ON/Dark-ON (auto-setting on teaching) Color mode: Consistent-ON/Inconsistent-ON (setting on teaching)

Mark mode: max. 45µs; color mode: max. 150µs

Mark mode: 2-level teaching/Limit teaching; Color mode: 1-level teaching

IP67 (IEC)

Ambient temperature Emitting element Connection method

Cable 2m

-10 to +55°C
Combined red/green/blue LED (Peak emission wave length: 640nm/525nm/470nm)
M12 connector (note 2)

Dimensions (HxWxD)

35×24×57mm

35×24×71.5mm

Accessories
Notes: 1.) Suffix -Z=M12 connector type 2.) Cable is not included in delivery. Please select under accessories (page 129)

M4 screws with washers, 2 pcs.

63
Photoelectric Sensors Fiber-optic Sensors
Standard Fibers Fiber Sensors Communication Units Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors Accessories
LX-100

64 LASER SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

EX-L200
Miniature laser sensor with
a built-in amplifier!

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Minute object sensing type EX-L211 (thru-beam)
The beam of the EX-L200 series is purposely widened to have a lower beam density and little beam spread so that when detecting minute objects, even a slight change in the light received intensity will not be missed.

 Minute detection (reflective)
With a repeatability of 0.02mm the sensor is perfectly suited for positioning tasks.

EX-L200

A 0.3mm minute object is detectable at any location between the emitter and receiver!

Laser beam has little beam spread!

 Environmental resistance
Thanks to the IP67 casing, the sensor is suitable for installation in humid and dusty environments.

 Easy alignment
Beam alignment is carried out by looking at the red spot reflected on the beam alignment screen to match with the actual object. The optimum position can be understood at a glance by looking at the beam alignment screen and stability indicator (green).

Object to be sensed

Stability indicator (Green) Beam alignment screen

Bright red spot

Shadow of object to be sensed

Easy adjustment by reflecting the shadow of the detection object.

65

Typical applications
Detecting ICs that are out of position in multiple palettes

Detecting the tip of a very thin pipe

Detecting objects from an opening

Detecting very small objects

Technical specifications

Type

Model no.

NPN output PNP output

Sensing range

Emission spot size

Object to be sensed Power supply voltage Output Response time Emitting element Protection Ambient temperature Material Connection method Dimensions (HxWxD) Accessories

Thru-beam type

EX-L211 EX-L211P
1m 6x4mm at 1m Ø 2mm (opaque)

EX-L212 EX-L212P
3m 8x5.5mm at 1m Ø 3mm (opaque)

25.9x 8.2x12mm Mounting plates MS-EXL2-2 2 pcs.

Retro reflective type EX-L291

Spot reflective EX-L221

Diffuse reflective type Convergent reflective spot
EX-L261

Convergent reflective line spot
EX-L262

EX-L291P

EX-L221P

EX-L261P

EX-L262P

4m 6x4mm at 1m Ø 25mm (opaque)

45 to 300mm Ø 1mm at 300mm

20 to 50mm
Ø 1mm at 50mm (convergent point: 22mm)
Opaque, transparent

20 to 70mm
1x5mm at 50mm (convergent point:
22mm)

12 to 24VDC ±10%

PNP / NPN open-collector transistor, max. 50mA

Max. 0.5ms

Red semiconductor laser (class 1)

IP67 (IEC)

­10 to +55°C

Enclosure: PBT, front cover: acrylic; lenses: glass

Cable, 2m

29.9x8.2x13mm

29.9x8.2x13.5mm

Reflector RF330, mounting plate MS-EX-L2-3 1 pc.

Mounting plate MS-EX-L2-3 1 pc.

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
EX-L200

66 LASER SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors

 4 types of identically sized sensor heads available
They are approximately the same size as general purpose photoelectric sensors, and the mounting method is identical.

Accessories

Long sensing range line reflective type: LS-H22

LS-400

Long sensing range spot reflective type: LS-H21 (Class 1 type is also available.)

Identical shape and mounting

Coaxial retroreflective type: LS-H91 Long sensing range coaxial retroreflective type: LS-H92

(Class 1 type is also available.)

General purpose photoelectric sensor CX-400 series

Slim size
11.2mm

Industry standard mounting pitch
25.4mm
 Coaxial reflective type with a long sensing range of 30m
The introduction of the LS-H92 long sensing range coaxial reflective type sensor means that even longer sensing ranges are now possible.

 Spot size adjustment
The long sensing range spot reflective type and long sensing range line reflective type have a built-in spot-size adjuster that enables spot size adjustment according to the object for optimal setting.

LS-400
User-friendly, advanced high precision laser sensing!

 Accurately senses the minutest variations
When sensing at close range or when the target objects are transparent or minute, adjust the sensor receiving sensitivity to one of 3 levels for the optimal setting. In addition, changing the receiving sensitivity will not affect the response time.
 Easy setting, dual display
Equipped with 2 large 4-digit digital displays. While checking the current light-receiving amount (red display), the optimal threshold value (green display) can be set easily.

10 mm thickness

Threshold value Green LED, 4 digits (max. display: 9999)

Current light receiving amount display Red LED, 4 digits (max.: 9999)

Large jog switch

Large MODE key

 Wiring and space savings
The quick-connection cables enable reductions in wiring (connector type). The connections and man hours for the intermediate terminal block setup can be reduced and valuable space saved. Also LS-400 series amplifiers can be connected side-byside with FX-300/FX-500 series fiber sensors.

Spot-size adjuster (multiple turn)

Fiber sensor

67

Typical applications

Interference prevention
The automatic interference prevention function protects against interference among up to 4 sensors.

Emission halt function
Using the emission halt function, the laser beam can be stopped via external input, e.g. when a spot appears within the visual range of an image processor.

External teaching function
Teaching can be conveniently performed externally for laser sensors installed inside a device.

IC pin check from remote position Checking protrusion of glass substrate

LS-H21

Technical specifications

 Sensor heads

Coaxial retroreflective

Diffuse reflective

Type

Standard

Long sensing range type

Long sensing range spot-reflective

Long sensing range line
reflective

Model no. (note 1)

LS-H91(F) (-A) (note 2)

LS-H92(F)

LS-H21(F) (-A) (note 2)

LS-H22(F) (note 3)

Sensing range

0.1 to 7m (U-LG) 0.1 to 5m (STD) 0.1 to 3m (FAST/H-SP)

0.2 to 30m (U-LG) 0.2 to 20m (STD) 0.2 to 10m (FAST/H-SP)

30 to 1.000mm (U-LG) 30 to 500mm (STD) 30 to 300mm (FAST/H-SP)

30 to 1.000mm (U-LG) 30 to 500mm (STD) 30 to 300mm (FAST/H-SP)

Ambient temperature

­10 to +55°C

Emitting element

Red semiconductor laser, LS-Hp: Laser class 2, LS-Hp-A: Laser class 1,

Dimensions (W×H×D)

11.2×31×25mm

Accessories

Reflector RF-330 1 pc., warning label (English) 1 pc.

Reflector RF-230 1pc. warning label (English) 1 pc.

Warning label (English) 1 pc.

LS-MR1 Lens attachment for line reflective
1 pc., warning label (English)
1 pc.

Notes: 1.) LS-Hx conforms to IEC/JIS/GB standards
LS-HxF conforms to FDA/IEC/JIS standards 2.) LS-H91(F)-A, LS-H21(F)-A: Class 1 type 3.) LS-H22(F) = LS-H21(F) with the LS-MR1 lens attachment for line reflective type

 Amplifiers
Type

Connector type (note)

Cable type

Model no.

NPN output PNP output

LS-401 LS-401P

LS-401-C2 LS-401P-C2

Power supply voltage

12 to 24VDC ±10%

Output

PNP / NPN open-collector transistor, max. 100mA

Output operation Response time Digital display Automatic interference prevention function
Ambient temperature
Connection method

Selectable either Light-ON or Dark-ON, with jog switch
max. 80µs (H-SP), max. max. 150µs (FAST), max. 500µs (STD), max. 4ms (U-LG), selectable with jog switch
4 digit (green) and 4 digit (red) LED display

Incorporated (up to four sets of sensor heads can be mounted close together;
however disabled when in H-SP mode)
­10 to +55°C (If 4 to 7 sensors are mounted close together: ­10 to +50°C) (If 8 to 16 sensors are mounted close together: ­10 to +45°C)

Connector (note)

Cable, 2m

Dimensions (W×H×D)

10×30×75mm

Note: The cable for amplifier connection is not supplied as an accessory with the connector type amplifier. Please select under accessories (page 129)

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
LS-400

68 LASER SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

LS-500
Miniature laser head with user-friendly amplifier

Safety Sensors

Pressure & Flow Sensors
Inductive Proximity
Sensors Measurement
Sensors Ionizers/ Electrostatic Sensors
Accessories
LS-500

Features

 Different sensor heads available
The LS-500 series of laser sensors offers four different laser heads. Select the appropriate shape of the heads depending on the requirements of your application.

Actual size M6

Body: Stainless steel (SUS)
Operation indicator (receiver only)

30 mm

 Multifunctional amplifier
The LS-500 series amplifier with its clearly laid-out display offers a user-friendly design. The definition of settings, such as the adjustment of threshold values, database and logic functions, is quite simple. The model with the analog current output provides a comfortable reading out of measurement values.
 Easy to combine
Due to its design and the possibility to mount the sensor on a DIN rail, the LS-500 can be connected quickly and easily to other sensors such as fiber amplifiers or pressure sensors.

 Robust sensor head
The robust sensor head is made of stainless steel and can be used under rough mounting conditions. The type with M6 screws is mountable even in the smallest spaces. You can check immediately with the LED indicator at the receiver whether the light is received correctly.

Reflective surface
Emitting element

Laser light
Sensing object Reflected light

Coaxial principle

Receiving lens Receiving element

Reflective photoelectric sensor
Emitting part
Receiving part
Coaxial design
Receiving part

FX-500 fiber sensor LS-500 laser sensor

 Highest precision
With the help of the coaxial precise light direction, the object sensing can be executed even through smallest openings. With a beam diameter of max. 6mm the retroreflective type has a sensing range of up to 2.5m.

69

Typical applications
Position control of a workpiece Detecting marks in a mold

Detecting workpieces through a Detection of a transparent foil worktop

Technical specifications
 Sensor heads

Type Model no.

Cylindrical LS-H101

Thru-beam

Rectangular LS-H102

Coaxial reflective type ­
LS-H201

Coaxial retroreflective type ­
LS-H901

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

Sensing range Ambient temperature Emitting element Dimensions ( ØxD)/ (HxWxD) Accessories

1m
M6x30mm M6 screws, 4 pcs., washer,
2 pcs.

1m

600mm (U-LG), 300mm (STD), 150mm (H-SP)

0.01 to 2m (U-LG), 0.01-1m (STD), 0.01-1m (H-SP)

­10 to +55°C

Red semiconductor laser (laser class 1)

8.2x26x12mm
MS-EXL2-2 (mounting plate) 2 pcs.

6.4x24x18mm

MS-LS-1 (mounting bracket) 1 pc.

MS-LS-1 (mounting bracket) 1 pc. RF-330 (reflector) 1 pc.

LS-500

 Amplifiers

Type

Connector type (note)

Cable type

Model no.

NPN output PNP output

LS-501 LS-501P

LS-501-C2 LS-501P-C2

Supply voltage

12 to 24V DC+10/-15%

Output

PNP/NPN open-collector transistor, max. 50mA

Analog output

-

4 to 20mA

Output operation

Selectable either Light-ON or Dark-ON

Response time

Max. 60µs (H-SP), 150µs (FAST), 250µs (STD), 500µs (LONG), 5ms (U-LG), 24ms (HYPR)

Digital display

4 digit, dual LED display (green and red)

Automatic interference prevention function

Built-in (up to 4 sensors: STD, LONG, U-LG, H-SP; up to 2 sensors: FAST; 0 sensors: HYPR)

Ambient temperature

-10 to +55°C (if 4 to 7 units are mounted close together: -10 to +50°C, if 8 to 16 units are mounted close together: -10 to 45°C)

Connection method

Connector (note)

2m cable

Dimensions (HxWxD) Note: Cable is not included in delivery. Please select under accessories (page 129)

10x32x77mm

70 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Easy installation of emitter and receiver thanks to improved optical properties
Thanks to a higher emission power, the SF4D not only works reliably on shorter distances, but also covers a longer sensing range up to 15m.

SF4D
15m sensing range

SF4D Typ 4 · PLe · SIL3 Robust safety light curtain

 Main functions
> Operation monitoring

» Monitoring of the incident beam intensity and extraneous light

» I/O monitoring
> Error history display

*2 SF4D series only

> Light blockage history, unstable light incidence history

> Muting setting function

> Override setting function

> Blanking setting function (both fixed and floating blanking)

> External device monitoring setting function

> Auxiliary output setting functions

Which functions are available depends on the synchronization method and the type of cables (5-core, 8-core, 12-core) used.

 Twisting- and bending-resistant design
The new interior design makes the safety light curtain more rigid and thus more robust. The SF4D does not bend or twist as easily when it comes into contact with other objects.

Resists twisting

Resists bending

Resists shock

The safety output is separated from IO-Link communication.
Safety Light Curtain SF4D series

PC
PLC master unit

*2

Safety PLC

*1

*1

*1

NEW

IO-Link

Communication Unit

SFD-WL3

*1: 8-core cable for safety light curtain (optional) *2: 4-core cable with M12 connector (commercially available, see note)

Note: The master and the communication unit must be connected with a cable of min. Ø0.3mm2. The total length of the cable must not exceed 20m.

Selection of light curtain
Typical applications
Serial connection of 5 safety light curtains for roboter housing

71

Monitoring of received light intensity and extraneous light during operation
Automobile production with muting

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

SF4D

Technical specifications

Typ

Finger protection type

Hand protection type

Arm / Foot protection type

Model no.

SF4D-F (notes 1,2)

SF4D-H

SF4D-A

Safety category

Typ 4, PLe, SIL3

Sensing height

150 to 1270mm

150 to 1910mm

Sensing range

0 to 12m

0 to 15m

Resolution

10mm

20mm

40mm

Object to be sensed

Min. Ø 14mm (opaque)

Min. Ø 25mm (opaque)

Min. Ø 45mm (opaque)

Power supply

24V DC ±10%

Response time

ON  OFF: max.10ms, OFF  ON: max. 50ms

Control outputs

OSSD1 and OSSD2 (2 x PNP or 2 x NPN open collector transistor, switchable), max. 350mA

Emitting element

Infrared LED

Protection

IP67/ IP65 (IEC)

Ambient temperature

-10 to +55°C

Material

Frame: Aluminium / Enclosures: Acrylic, Polycarbonate, Nylon

Connection method

Connector

Dimensions (HxWxD)

Hx30x28mm (H= protective height)

Notes: 1.)  Number of beam channels 2.) For a system configuration, please contact your sales office or service hotline: +49 89 45354-2737

72 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors

 Finger protection type (min. object to be sensed  14mm, 10mm beam pitch)

Model no. SF4D-F15

Sensing range

No. of beam axes 15

Fiber-optic

SF4D-F23

23

Sensors

SF4D-F31

31

Standard Fibers

SF4D-F39

39

SF4D-F47

47

Fiber Sensors

Communication Units

SF4D-F55

0 to 7m (short mode) 0 to 12m (long mode)

55

SF4D-F63

(selectable by DIP switch)

63

Mark Sensors

SF4D-F71

71

Laser Sensors

SF4D-F79

79

SF4D-F95

95

Safety Sensors

SF4D-F111

111

Pressure &

SF4D-F127

127

Flow Sensors

Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Hand protection type (min. object to be sensed  25mm, 20mm beam pitch)

Model no. SF4D-H8 SF4D-H12 SF4D-H16 SF4D-H20

Sensing range

No. of beam axes 8 12 16 20

SF4D-H24

24

SF4D-H28

28

SF4D

SF4D-H32

32

SF4D-H36

0 to 9m (short mode)

36

0 to 15m (long mode)

SF4D-H40

(selectable by DIP switch)

40

SF4D-H48

48

SF4D-H56

56

SF4D-H64

64

SF4D-H72

72

SF4D-H80

80

SF4D-H88

88

SF4D-H96

96

Protective height 150mm 230mm 310mm 390mm 470mm 550mm 630mm 710mm 790mm 950mm 1110mm 1270mm
Protective height 150mm 230mm 310mm 390mm 470mm 550mm 630mm 710mm 790mm 950mm 1110mm 1270mm 1430mm 1590mm 1750mm 1910mm

 Arm / Foot protection type (min. object to be sensed  45mm, 40mm beam pitch)

Model no. SF4D-A4 SF4D-A6 SF4D-A8 SF4D-A10 SF4D-A12 SF4D-A14 SF4D-A16 SF4D-A18 SF4D-A20 SF4D-A24 SF4D-A28 SF4D-A32 SF4D-A36 SF4D-A40 SF4D-A44 SF4D-A48

Sensing range
0 to 9m (short mode) 0 to 15m (long mode) (selectable by DIP switch)

No. of beam axes 4 6 8 10 12 14 16 18 20 24 28 32 36 40 44 48

Protective height 150mm 230mm 310mm 390mm 470mm 550mm 630mm 710mm 790mm 950mm 1110mm 1270mm 1430mm 1590mm 1750mm 1910mm

Beam pitch 10mm
Beam pitch 20mm
Beam pitch 40mm

73

Features
 Sensor height = protective height
The length of the main unit equals the protective height so that installation is possible in places where space is limited. No blindzone occurs at the joints between light curtains when light curtains are connected in series.
 Finger/hand and arm/foot protection available

Finger protection type

SF4B-F

MMiinnimimumumsensseinngsoinbjgecot bject
"25m1m4mm
(1200mmmmbeabmeapmitchp) itch)

Hand protection type

SF4B-H

MMiinnimimumumsensseinngsoinbjgecot bject
25m2m5mm
(2200mmmmbebaemapmitchp)itch)

Arm / Foot protection type

SF4B-A

MinimMiunmimusmensesninsigngoobbjecctt
"25mm 45mm
(20 m(4m0mbmeabemamppitictchh)

 Response time of 14ms and constant safety distance
A fast response time of 14ms has been achieved regardless of the number of beam channels, the beam axis pitches and the number of units connected in series. This reduces calculation work required for the safety distances.
 A muting control function is provided to increase both safety and productivity
The light curtain is equipped with a muting control function that causes the line to stop only when a person passes through the light curtain, not when an object passes through.

Muting lamp

Light curtain SF4B series

SF4B (V2)
Type 4 · PLe · SIL3
New concepts combining greater safety and higher productivity!

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors

Pressure & Flow Sensors

Inductive Proximity Sensors

 Built-in safety relay
The light curtain has a built-in external device monitoring (EDM) function and an interlock function. The safety circuit is constructed so that a separate safety relay unit is not needed, and the control board is also more compact, both of which contribute to lower costs.

Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

 Improved ambient light immunity
The integrated ELCA function (Extraneous Light Check & Avoid) prevents interference from ambient light or other light curtains and even from welding plants.

SF4B (V2)

 Digital error indicator
If an error occurs, details of the error appear on the digital display so that maintenance can be carried out more quickly.

 Universal design that can be used anywhere in the world
The SF4B series combines PNP transistor output and NPN transistor output in a single model. Overseas equipment that uses PNP, replacement with NPN sensors, factories that are positively grounded, and transfer of equipment overseas are all situations where the control circuits for a single model are suitable for use worldwide.

Muting sensor CX-400 series

74 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors

Typical applications
Guarding space around welding robot
A spatter protection hood type perfect for welding devices is also available.

Fiber-optic Sensors

Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories Technical specifications

SF4-BH64

SF4B (V2)

Type Model no.

Finger protection type SF4B-Fp(V2) (note)

Hand protection type SF4B-Hp(V2)

Arm / Foot protection type SF4B-Ap(V2)

Safety category

Type 4, PLe, SIL3

Sensing height

230 to 1270mm

230 to 1910mm

Sensing range

0 to 7m (depending on type up to 9m)

Resolution

10mm

20mm

40mm

Object to be sensed

Min. Ø 14mm (opaque)

Min. Ø 25mm (opaque)

Min. Ø 45mm (opaque)

Power supply

24VDC +/­10%

Response time

ON  OFF: max. 14ms / OFF  ON: max. 90ms

Control outputs

OSSD1 and OSSD2 (2 x PNP or 2 x NPN open collector transistor, switchable), max. 200mA

Emitting element

Infrared LED

Protection

IP67 / IP65 (IEC)

Ambient temperature

­10 to +55°C

Material

Frame: Aluminium / Enclosures: Acrylic, Polycarbonate, ABS

Connection method

Connector

Dimensions (HxWxD)

Hx30x28mm (H= protective height)

Notes: For a system configuration, please contact your sales office or service hotline: +49 89 45354-2737

Arm / Foot protection type

Hand protection type

Finger protection type

 Sensing height
Sensing range 0-7m
0-9m 0-7m 0-9m 0-7m

Model no. SF4B-F23(V2) SF4B-F31(V2) SF4B-F39(V2) SF4B-F47(V2) SF4B-F55(V2) SF4B-F63(V2) SF4B-F71(V2) SF4B-F79(V2) SF4B-F95(V2) SF4B-F111(V2) SF4B-F127(V2)
SF4B-H12(V2) SF4B-H16(V2) SF4B-H20(V2) SF4B-H24(V2) SF4B-H28(V2) SF4B-H32(V2) SF4B-H36(V2) SF4B-H40(V2) SF4B-H48(V2) SF4B-H56(V2) SF4B-H64(V2) SF4B-H72(V2) SF4B-H80(V2) SF4B-H88(V2) SF4B-H96(V2)
SF4B-A6(V2) SF4B-A8(V2) SF4B-A10(V2) SF4B-A12(V2) SF4B-A14(V2) SF4B-A16(V2) SF4B-A18(V2) SF4B-A20(V2) SF4B-A24(V2) SF4B-A28(V2) SF4B-A32(V2) SF4B-A36(V2) SF4B-A40(V2) SF4B-A44(V2) SF4B-A48(V2)

Protective height (mm) 230 310 390 470 550 630 710 790 950 1110 1270
230 310 390 470 550 630 710 790 950 1110 1270 1430 1590 1750 1910
230 310 390 470 550 630 710 790 950 1110 1270 1430 1590 1750 1910

Installation height (mm) 286 366 446 526 606 686 766 846 1006 1166 1326
286 366 446 526 606 686 766 846 1006 1166 1326 1486 1646 1806 1966
286 366 446 526 606 686 766 846 1006 1166 1326 1486 1646 1806 1966

75

No. of beam axes 23 31 39 47 55 63 71 79 95 111 127
12 16 20 24 28 32 36 40 48 56 64 72 80 88 96
6 8 10 12 14 16 18 20 24 28 32 36 40 44 48

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
SF4B (V2)

76 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Compact size
The SF4B-C series has been designed to mount flush with the aluminum frame. This means the machine opening will not be made any narrower. It can even be installed with zero blind zone.

SF4B-C
Type 4 · PLe · SIL3
Mounts flush on aluminum frames
 The SFB-HC handy controller (optional)
offers easy access to settings for a range of functionality.

SF4B-C

Width

20 Just

mm

Depth
27.4mm
 Easy mounting on aluminum frame
Mounts ush on aluminum frames.

 With the pigtailed type, the large indicator is easy to see also from the side
The SF4B-C series incorporates a large multi-purpose indicator (orange) positioned at workers' eye level. The indicator signals the presence of the light curtain, helping to prevent stoppages due to inadvertent interruption of its beams. The indicator can be used in a variety of applications, including as a muting indicator or operation indicator. The large multi-purpose indicator shines brightly through the plastic body to ensure exceptional visibility from the side.

Buried mounting (side) The light curtain mounts flush, even in installations with buried mounting.
> There is no risk of workpieces bumping into
the light curtain.
Rear mounting
> The light curtain fits onto a 20 × 20mm alumi-
num frame perfectly.

77

Technical specifications

Pigtailed type (note 1, 2)

Cable type

Type

Hand protection type

Arm protection type

Hand protection type

Arm protection type

Model no.

SF4B-HpCA-J05

SF4B-ApCA-J05

SF4B-HpC

SF4B-ApC

Safety category

Type 4, PLe, SIL3

Protective height

263.4 to 1943.4mm

Sensing range

0 to 7m

Beam pitch

20mm

40mm

20mm

40mm

Object to be sensed

Min. Ø 25mm (opaque)

Min. Ø 45mm (opaque)

Min. Ø 25mm (opaque)

Min. Ø 45mm (opaque)

Supply voltage

24V DC ±10%

Response time

ON  OFF: max. 14ms / OFF  ON: max. 90ms

Control outputs

OSSD1 and OSSD2 (2 x PNP or 2 x NPN open collector transistor, switchable), max. 200mA

Emitting element

Infrared LED, 850nm

Protection

IP65 (IEC)

Ambient temperature

-10 to +55°C

Material

Polycarbonate

Connection method

12-wire PVC cable with connector, 0.5m

8-wire PVC cable, 5m

Dimensions (HxWxD)

Hx20x27.4mm (H= depending on protective height)

Notes: 1.) For a system configuration, please contact your sales office or service hotline: +49 (0) 89-45354-2737 2.) Integrated muting function

Hand protection type

 Protective height
Model no. Pigtailed type (note)
SF4B-H12CA-J05 SF4B-H16CA-J05 SF4B-H20CA-J05 SF4B-H24CA-J05 SF4B-H28CA-J05 SF4B-H32CA-J05 SF4B-H36CA-J05 SF4B-H40CA-J05 SF4B-H48CA-J05 SF4B-H56CA-J05 SF4B-H64CA-J05 SF4B-H72CA-J05 SF4B-H80CA-J05 SF4B-H88CA-J05 SF4B-H96CA-J05

Cable type SF4B-H12C SF4B-H16C SF4B-H20C SF4B-H24C SF4B-H28C SF4B-H32C SF4B-H36C SF4B-H40C SF4B-H48C SF4B-H56C SF4B-H64C SF4B-H72C SF4B-H80C SF4B-H88C SF4B-H96C

Protective height (mm)
263.4 343.4 423.4 503.4 583.4 663.4 743.4 823.4 983.4 1143.4 1303.4 1463.4 1623.4 1783.4 1943.4

Installation height (mm) (note)
294.4 374.4 454.4 534.4 614.4 694.4 774.4 854.4 1014.4 1174.4 1334.4 1494.4 1654.4 1814.4 1974.4

SF4B-A8CA-J05

SF4B-A8C

343.4

SF4B-A12CA-J05

SF4B-A12C

503.4

SF4B-A16CA-J05

SF4B-A16C

663.4

SF4B-A20CA-J05

SF4B-A20C

823.4

Arm protection type

SF4B-A24CA-J05

SF4B-A24C

983.4

SF4B-A28CA-J05

SF4B-A28C

1143.4

SF4B-A32CA-J05

SF4B-A32C

1303.4

SF4B-A36CA-J05

SF4B-A36C

1463.4

SF4B-A40CA-J05

SF4B-A40C

1623.4

SF4B-A44CA-J05

SF4B-A44C

1783.4

SF4B-A48CA-J05

SF4B-A48C

1943.4

Note: The installation height depends on the mounting bracket. Specifications with standard mounting bracket MS-SF4BC-1

374.4 534.4 694.4 854.4 1014.4 1174.4 1334.4 1494.4 1654.4 1814.4 1974.4

No. of beam axes
12 16 20 24 28 32 36 40 48 56 64 72 80 88 96
8 12 16 20 24 28 32 36 40 44 48

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
SF4B-C

78 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors

SF4C

Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Large, built-in, multi-purpose LED indicators
Large LED bars on each side of the light curtain provide a wide visibility indicator that can be customized for various applications by means of independent external inputs. The indicator can be used as an operation indicator (muting) or job indicator, etc.

SF4C  Finger/hand protection
The SF4C series covers a sensing height of 160mm to 640mm. This is true for the finger and hand protection types (resolution up to 10 or 20mm).

Type 4 · PLe · SIL3
Ultra-slim light curtain safeguards machines without sacrificing productivity
 IP67 (IEC)
An IP67 (IEC) rating is achieved with an ultra-slim size for protection from environmental factors.
 Mutual interference is reduced without need for interference prevention lines
The light curtain is equipped with the ELCA (Extraneous Light Check & Avoid) function, which has been proven to be strong against mutual interference. Because it automatically shifts the scanning time of the light curtain in order to avoid interference, it is not necessary to wire interference prevention lines between machinery.

Green

Red

Green / Red

series
ent and streamlined i-purpose indicator"
Job indicator
Power source Light curtain SF4C Control circuit

External input device
(Lighting / blinking signal)
Large multi-purpose indicator
Input 1
Input 2

 Can be used in a variety of applications for simplified equipment (large multi-purpose indicator)
Wire-saving when connecting to safety devices. Contact outputs such as emergency stop switches or safety door switches can be connected to the light curtain. Also, by using the handy-controller SFC-HC, up to three sets of light curtains can be cascade connected for a consolidated safety output.

 A fast response time of 7ms* for all models
A fast response time of 7ms* for all models regardless of the number of beam channels. This reduces the safety distance as well as the calculation work required for the safety distance among models with different beam channels.
* When connecting safety sensors (light curtains, etc.) to the safety input, the response time will be the total time of connected units.
 Safety, productivity, and cost reduction [muting control function]
The muting sensors and muting lamps can be connected directly to the light curtain. Furthermore, the large multi-purpose indicators can be used as muting lamps, which contribute to less wiring troubles, improvement of safety, productivity, and cost reduction.

79

Typical applications
Use of internal muting lamp
There is no need to buy and install a separate muting lamp.

Selective muting area
Separate muting control function for each beam channel.

Industry first!
Wire-saving when connecting to safety devices (safety input function).

Technical specifications

Type

Finger protection type

Hand protection type

Model no.

SF4C-Fp (note)

SF4C-Hp

Safety category

Type 4, PLe, SIL3

Sensing height

Depending on types (160 to 640mm)

Sensing range

0 to 3m

Resolution

10mm

20mm

Object to be sensed

Min. Ø 14mm (opaque)

Min. Ø 25mm (opaque)

Power supply

24VDC +10/­15%

Control outputs

OSSD1 and OSSD2 (2x PNP or 2x NPN transistor outputs with open collector, switchable, max. 200mA)

Response time

ON  OFF max. 9ms / OFF  ON max. 90ms

ON  OFF max. 7ms / OFF  ON max. 90ms

Rated current consumption

Max. 270mA (depending on type)

Protection

IP67 / IP65 (IEC)

Ambient temperature

­10 to +55°C

Material

Polycarbonate

Connection method

Cable, 5m or 0.5m with connector

Dimensions (HxWxD)

Hx13.2x30mm (H= protective height)

Note: For a system configuration, please contact your sales office or service hotline: +49 89 45354-2737

Finger protection type

 Sensing height
Cable type SF4C-F15 SF4C-F23 SF4C-F31 SF4C-F39 SF4C-F47 SF4C-F55 SF4C-F63

Model no.

Cable with connector SF4C-F15-J05 SF4C-F23-J05 SF4C-F31-J05 SF4C-F39-J05 SF4C-F47-J05 SF4C-F55-J05 SF4C-F63-J05

Protective height (mm)
160 240 320 400 480 560 640

Installation height (mm)
160 240 320 400 480 560 640

No. of beam axes
15 23 31 39 47 55 63

Hand protection type

Cable type SF4C-H8 SF4C-H12 SF4C-H16 SF4C-H20 SF4C-H24 SF4C-H28 SF4C-H32

Model no.

Cable with connector SF4C-H8-J05 SF4C-H12-J05 SF4C-H16-J05 SF4C-H20-J05 SF4C-H24-J05 SF4C-H28-J05 SF4C-H32-J05

Protective height (mm)
160 240 320 400 480 560 640

Installation height (mm)
160 240 320 400 480 560 640

No. of beam axes
8 12 16 20 24 28 32

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
SF4C

80 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement
Sensors  We also offer safety light curtains with

Ionizers/ Electrostatic
Sensors

safety category 2
> Protective height: 160 to 1912mm

> Accessories

Sensing range: 0 to 13m

> Response time: max. 15ms (ON  OFF)

> Arm and hand protection type

> SF2B/SF2C

Integrated status LEDs and display

> Series connection without blind zone

> Features: Interference suppression, series connection,

emission halt function

SF2B/SF2C
Safety category 2 Excellent basic functions at a
reasonable price
 Arm / foot protection type SF2B-A
Min. sensing object ø 47mm (beam pitch 40mm)
 Hand protection type SF2B-H
Min. sensing object ø 27mm (beam pitch 20mm)

Typical applications
Protection against malfunction caused by extraneous light

Protection against mutual interference thanks to interference prevention

Customization of automation products
Panasonic has been perfecting the art of customization for over 10 years. Our experts work with customers, engineers, and purchasing and logistic departments to configure the most suitable customized solution in terms of product modification, packaging, labeling, pre-assembly and other features. High quality is assured thanks to multiple product tests that are conscientiously documented. Customized automation products can reduce your production costs, avoid production errors, and improve the quality of your final product.

 Customized cabling and  Application specific

interfacing

setting of sensors

 Re-packaging for

 Sensors bundled with

immediate customer use

PLC/HMI as a solution

 Customer specific mounting of connectors on Panasonic Industry sensors

https://industry.panasonic.eu

82 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

SG-P
Non-contact safety door switch

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors Ionizers/
Electrostatic Sensors
Accessories
SG-P

 High visibility
Door switches installed on the inside of doors are difficult to see from the outside, so it is hard to check whether the doors are open or closed. The SG-P series units are highly visible from the outside, thus allowing reliable confirmation. The SG-P series eliminates the need to install switches on the outside of equipment, and it contributes to the simplification of equipment

For frame-less doors
Compact type: SG-P1010-p / SG-P2010-p
 No prior pairing
Each switch body and actuator can be easily paired by bringing them close to each other and supplying power during the initial setup. When the units are cascade-connected, turning on the power completes the pairing procedures in a batch, thus reducing the man-hours required for the setup.

 High level coded actuator
Intentional deactivation of a safety switch can lead to serious accidents. The SG-P series with high level coded actuators models detect only the paired actuators. They support the ISO 14119 coding level and prevent intentional deactivation of safety switches.

 30 units in series
Previously, when cascade connection was used, extra manhours were required for connecting wires to the switches for linked operation. When the SG-P series is installed, the standard model serves as a master unit and outputs safety signals (OSSD1 / 2) in a batch. No extra wiring work is necessary for cascade connection of the sub units that serve as slave units. A maximum of 30 units can be connected, thus contributing to the reduction of equipment wiring work.

Each master unit can be connected with up to 29 slave units.

Slave (1)

Slave (29)

Master

Safety controller

Switch bodies

Automatic pairing during initial power-on process

Power supply unit

Actuators

83

Large and bright indicators notify the open / Closed conditions of machine room doors

When any of the safety switches connected in series enters a non-detecting state, its indicator lights up in red and the

indicators of all other safety switches flash in green to notify the operator.

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors

Standard Fibers
Fiber Sensors Communication Units
Mark Sensors

Laser Sensors

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

SG-P

Open door is indicated by the indicator lit up in bright red.

Indicators of switches on the other (closed) doors linked to the open door flash in green to indicate that the machine is in an unsafe condition.

Technical specifications

Type Model no. Applicable standards Operating distance Power supply voltage Output Response time Material Connection method Degree of protection Pollution degree Dimensions (HxWxD)

Master, PNP output

Master, NPN output

Slave

SG-P-M-P

SG-P-M-N

SG-P-S

ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119, EN 60947-5-3, EN 300 330, EN 301 489-1

Sao (OFFON): 5mm, Sar (ONOFF): 15mm

24V DC

2 x PNP open-collector transistor, max. 100mA

2 x NPN open-collector transistor, max. 100mA

­

For single unit: ONOFF max. 100ms, OFFON max. 100ms For multiple units: Time for single unit + 5ms × (number of connected units - 1)
Switch body: PBT, PC, stainless steel, Silicone rubber. Actuator: PBT, PC (only visible type)

6­core cab tire cable, 5m

4­core cab tire cable, 3m

IP65 (IEC)

3 inside 2

Compact type: 93x25x15mm; actuator: 56x13x15mm Visible type: 93x25x15mm; actuator: 52x32x15mm

84 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors

ST4
Type 4 · PLe · SIL3
Cascadable thru-beam sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Series connection of six sets of sensor heads to one controller
The concept of connecting six sets of sensor heads to one controller in series offers you maximum flexibility to solve your safety application.

 Beam axis alignment and operation confirmation
ST4 The beam interruption indicator is incorporated in both the emitter and receiver. This indicator can be used not only to confirm operation but also to align the beam axis.

 Compact sensor head saves space
The size of this type 4 long sensing range type is similar to general purpose photoelectric sensors.
 IP67 (IEC)
The sensor heads can be used safely even in rough production environments.
 Interference prevention
The emission amount adjuster can be used to prevent interference to the surrounding sensors.

 Supports both PNP and NPN polarities
A single unit supports both PNP and NPN polarities, easing stock management.

Verzweigung An Steuereinheit
Verlängerungskabel

Emission amount adjustment function

85

Typical applications

Protection for long sensing ranges
Guard areas up to 15m in length, for example where protective fences are difficult to install.

Protection for small openings
For small openings where light curtains do not fit, ST4 sensor heads ensure safety.

Protection against nonauthorized entry
Sensor heads can be mounted flexibly and muting control implemented easily.

Technical specifications

 Sensor heads

Type

Cable length 0.2m

Cable length 1.0m

­

With sensitivity adjuster

­

With sensitivity adjuster

Model no.

ST4-A1-J02

ST4-A1-J02V

ST4-A1-J1

ST4-A1-J1V

Safety category

Type 4, PLe, SIL3

Cascading

Up to 6 pieces to one controller

Power supply

Supplied from controller (ST4-C11 or ST4-C12EX)

Sensing range

0 to 15m

Object to be sensed

Min. ø 9mm (opaque)

Emitting element

Infrared LED

Protection

IP67 (IEC)

Ambient temperature

­10 to +55°C

Material

Enclosure: PBT/Cover: acrylic

Connection method

Cable with connector enclosed, 0.2m

Cable with connector enclosed, 1.0m

Dimensions (HxWxD)

31x14x28mm

 Control device

Type

Standard

High-functional

Model no.

ST4-C11

ST4-C12EX

Safety category

Type 4, PLe, SIL3

Power supply

24VDC +10% / ­15%

Control outputs

OSSD1 and OSSD2 (2x PNP or 2x NPN transistor outputs with open collector, switchable, max. 200mA)

Response time

ON  OFF: max. 25ms, OFF  ON: max. 140ms

Current consumption

Max. 100mA (excluding sensor heads)

Max. 120mA (excluding sensor heads)

Protection

Enclosure: IP40 (IEC), Terminal: IP20 (IEC)

Ambient temperature

­10 to +55°C

Material

Enclosure: ABS

Connection method

Connector (sensors), terminal block

Dimensions (HxWxD)

130x46x80mm

Note: For a system configuration, please contact your sales office or service hotline: +49 89 45354-2737

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
ST4

86 SAFETY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement
Sensors  Space-saving and easy to wire

Ionizers/ Electrostatic
Sensors

> One SF-C21 can do the work of four
safety relay units.

Accessories

Input: 10 points / Output: 8 points
> Compact size

(height 97 mm × width 45 mm)

SF-C21

 Absolutely no programming skills required
> Eight preset logics, safety-certified and compatible to
control category 4 PLe
> The OFF delay time can be easily set by turning the
rotary switch
> Password protection prevents inadvertent changes to the
logic

SF-C21
Control unit for multiple safety solutions
 Application-based customization
> Easy to create reliable safety circuit > Configurator SF-C software to build
own safety circuits
 Easy to monitor status with a PLC
> Four auxiliary outputs are provided > RS-485 communications (MODBUS RTU)

Technical specifications

Model. no. Safety standards EMC standards Related standards Safety input Safety control output Auxiliary output
Logic selection function
Communication

SF-C21

IEC 61508-1 to 7, EN 61508-1 to 7(SIL3), ISO 13849-1 (up to Category 4, PLe), IEC 61131-2, IEC 61010-2-201, IEC 62061(SILCL3), UL 61010-1, UL 61010-2-201

IEC 61000-6-2, IEC 61326-3-1, EN 55011

IEC 60947-1, IEC 60947-5-1, IEC 60947-5-2, IEC 60947-5-5, IEC 60947-5-8, IEC 61496-1, IEC TS 62046, ISO 13851

2 × 4 inputs (ON  OFF max. 0.7ms; OFF  ON max. 10ms)

PNP open-collector transistor with 2 outputs x 2 (ON  OFF max. 10ms; OFF  ON max. 100ms)

PNP open-collector transistor with 1 output × 4 (Any of the auxiliary outputs can be customized using the software tool)

No. 0: Customization control No. 2: Parallel muting control No. 4: Partial stop control 1 No. 6: Two-hand control No. 8: Operation mode selection control

No. 1: Overall stop control No. 3: Sequential muting control No. 5: Partial stop control 2 No. 7: OR control

RS-485: Detachable spring-cage terminal block, USB: Mini-B male

Note: We also offer the safety control unit SF-C10 series (see next page), which is ideal for controlling Panasonic's safety light curtain, because its connectors make wiring easier

87

SF-C10
Less setup time for safety light curtains

Features
 Supports both PNP and NPN polarities
A single unit can be used for PNP / NPN input switching, reducing the number of parts that need to be registered.

 Slim design
22.5mm thickness for insertion even into narrow spaces inside panels.

SF-C13

 Removable terminal blocks reduce maintenance time

SF-C11

Removable terminal blocks are used. This reduces the work required for reconnecting wiring during maintenance

22.5mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
SF-C10

Removable! Uses a spring method

 Metal enclosure with an IP65 (IEC) protective structure

The strong metal enclosure has a built-in safety

SF-C12

relay. It has an IP65 protective structure so that it

can be set up individually without needing to be inserted into a

control panel.

 Three safety circuit systems packaged into SF-C14EX a single unit!
The unit has three different built-in safety circuits: Output circuit of the safety light curtain, muting safety circuit, and emergency stop safety circuit.

Connector in metal housing

88 PRESSURE & FLOW SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

DP-0
Compact and easy-to-use pressure sensor

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors Ionizers/
Electrostatic Sensors
Accessories
DP-0

 RUN and detailed setting mode
Pressure sensors of the DP-0 series operate in two different modes. RUN mode is used for quick access to settings like threshold values, zero point, and key lock functions. The detailed setting mode offers additional settings such as selecting the pressure unit or the response time. The two modes together help to achieve an optimum sensor performance.

Detailed setting mode
Pressure unit setting mode

RUN mode

Operation setting mode

NO / NC setting mode

· Threshold value setting · Zero point adjustment · Key lock setting / release

Response time setting mode
Display color setting mode

Settings initializing mode

 Functional design
The unit body is completely black to make the LCD display easier to see. The keys offer a firm and crisp clicking feel, thus making operating the sensor smooth and reliable.

 Compact & lightweight design
The unit body measures only 24.9mm in depth, which allows installation in a narrow space. The body weighs only 25g. The low weight is very advantageous if the sensor has to be mounted on moving parts, e.g. robot arms.

Approx.
25 g
24,9mm

Env. 40g
42,5mm

 Low and high pressure type available
The low pressure type can be used with positive or negative pressure. It is ideal for suction applications where it indicates malfunctions due to pressure changes. The high pressure type is suitable for positive pressure of up to 1MPa. It is ideal for applications where a reference pressure needs to be checked.

-100 kPa

0 kPa

Low pressure type

DP-001

High pressure type

100 kPa
DP-002

1 MPa

Typical applications
Monitoring suction pressure on electronic components

Checking reference pressure

Technical specifications

Type

Low pressure type

High pressure type

PNP Model no.
NPN

DP-001-P DP-001

DP-002-P DP-002

Type of pressure

Gauge pressure

Rated pressure range (note 2)

-1 to +1bar (-100 to +100kPa)

0 to +10bar (0 to 1MPa)

Pressure withstandability

5bar (500kPa)

15bar (1.5MPa)

Applicable fluid

Non-corrosive gas

Supply voltage

12 to 24V DC ±10%

Output

3x NPN or PNP transistor, max. 50mA

Response time

2.5, 25, 250ms (switchable)

Pressure port

M5 female thread

Degree of protection

IP40

Ambient temperature

-10 to +50°C

Material

Resin body type

Connection method

Connector (note 1)

Dimensions (HxWxD)

30x30x25mm

Accessories

CN-14A-C2 connector-attached cable 2m, 1 pc

Notes: 1.) The 2m cable CN-14A-C2 is included 2.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20°C. Reference pressure 1atm

89
IO-Link Sensors Photoelectric Sensors Fiber-optic Sensors
Standard Fibers Fiber Sensors Communication Units Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors Accessories
DP-0

90 PRESSURE & FLOW SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

DP-100
Pressure sensors with dual display

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors



The current and threshold values can be checked at the

Ionizers/ Electrostatic
Sensors

same time!

Accessories DP-100

Comparative Output 1 Operation indicator
Comparative Output 2 Operation indicator Multi-function type:
Analog voltage output Operation indicator

Main display Sub display

 Easy-to-read digital display!
A clear 12-segment make numbers and letters easy to read.
 High performance

Mode selection key Increment key

Decrement key

 Dual display allows direct setting of threshold value
Equipped with a 30mm square compact dual display. Because the current and threshold value can be checked at the same time, the threshold value can be set and checked smoothly without having to switch screen modes.
 3-color display (red, green, orange)

Current value
Threshold value
The main display color changes depending on the output status (ON/OFF operation) and while settings are being made. The sensor status can therefore be understood easily, and operating errors can be reduced.

The low pressure type displays measure- For low pressure ments in 0.1kPa at a resolution of 1/2000
and has a response time of 2.5ms (variable up to 5000ms).
Moreover it boasts ±0.5% F.S. temperature characteristics and
±0.1% F.S. repeatability.

 Copy function saves time and reduces human error

Sensors can be connected to a master sensor one by one and settings copied to them. When making the same settings for mul-

Details transmitted
Details received Details copied

tiple sensors, this prevents setting

errors from occurring and reduces

the number of changes required to instruction manuals when

equipment designs are changed.

 Equipped with auto-reference and remote zero-adjustment functions A precise pressure management is possible
If the reference pressure of the device changes, the auto-reference function partially shifts the comparative output judgment level by the amount that the reference pressure shifts and resets the display value to zero. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are desired.

Main display

OFF: Green (or Red)

ON: Red (or Green)

Set: Orange

During normal operation

During setting

91

Typical applications
Confirming suction of electronic component

Confirming reference pressure

Leak test for PET bottles

Technical specifications

 Cable types

Type

Standard

High-function controller

Model no.

Asian

DP-101 (note 1)

DP-102

DP-101A

DP-102A

European

DP-101-E-P

DP-102-E-P

DP-101A-E-P

DP-102A-E-P

M5 female thread Short porttype Rated pressure range (note 3) Applicable fluid

DP-101-M-P
­1bar to +1bar (-100.0 to +100.0kPa)

DP-102-M-P

DP-101A-M-P

­1bar to +10bar (-0.1 to +1.0MPa)

­1bar to +1bar (-100.0 to +100.0kPa)

Non-corrosive gas

DP-102A-M-P
­1bar to +10bar (-0.1 to +1.0MPa)

Power supply

12 to 24VDC ±10%

Output

PNP / NPN open-collector transistor, max. 100mA

Analog output

­

4 to 20mA/0 to 10V

Response time

2.5ms, 5ms, 10ms, 25ms, 50ms, 100ms, 250ms, 500ms, 1000ms, 5000ms, selectable by key operation

Display Pressure port Connection method

3-color LCD display, 12 segments, 4 digits
Asian: M5 female thread + R (PT) 1/8 male thread European: M5 female thread + G 1/8 male thread
Connector (note 2)

Dimensions (HxWxD)

30x30x42.5mm

Accessories

CN-14A-C2 Connector attached cable 2m, 1 pc.

Notes: 1.) Suffix-E = Air supply M5 female thread and G 1/8 male thread
Suffix-M = M5 short port type Suffix-P = PNP output 2.) CN-14A-C2 cable 2m is included in delivery 3.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20°C. Reference pressure=1atm

 M8 connector types

Type

Standard

Multifunction

Model no. Rated pressure range (note 1) Applicable fluid

DP-111-E-P-J
­1bar to +1bar (-100.0 to +100.0kPa)

DP-112-E-P-J

DP-111A-E-P-J

­1bar to +10bar (-0.1 to +1.0MPa)

­1bar to +1bar (-100.0 to +100.0kPa)

Non-corrosive gas

DP-112A-E-P-J
­1bar to +10bar (-0.1 to +1.0MPa)

Power supply

12 to 24VDC ±10%

Output

PNP open-collector transistor, max. 100mA

Response time

2.5ms, 5ms, 10ms, 25ms, 50ms, 100ms, 250ms, 500ms, 1000ms, 5000ms, selectable by key operation

Analog volt. output / external input

--

Incorporated

Ambient temperature

­10 to +50°C

Pressure port Material Connection method

G1/8 male thread + M5 female thread
Enclosure: PBT (glass fiber reinforced); LCD display: Acrylic; Pressure port: Stainless steel (SUS303); Thread part: Brass (nickel plated);
Switch part: Silicone rubber, M8 connector part: Nickel-plated brass/brass gold plated contacts
M8 connector (note 2)

Dimensions (HxWxD)

30x30x47.5mm

Accessories

Unit selection plate: 1 set

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20°C. Reference pressure=1atm 2.) Cable not included in delivery, please select under accessories (page 129)

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
DP-100

92 PRESSURE & FLOW SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors

 Automatic sensor head recognition
The controller automatically recognizes sensor heads when they are connected, even if their rated pressure ranges are different.

Accessories
 Dual display and direct setting

DPC-100/ DPH-100

The dual display allows you to check current and threshold values simultaneously.
To facilitate setting operations, three modes have been devised:
> "RUN mode" is for operation settings that are carried out
daily
> "MENU SETTING mode" for basic settings > "PRO mode" for special and detailed settings
Controllers can be connected to a master controller one by one, and the master can transmit settings to the slave controllers. This significantly reduces time required when you need to make multiple, identical settings, or during production changeovers. Moreover, it reduces the possibility for error in such cases.

DPC-100/ DPH-100
Single-axis type digital pressure sensor with optional dual 3-color
display
 Direct installation using a hexagonal wrench
The sensor head is tightened with a hexagonal wrench, making installation easy, especially in tight spaces.

Typical applications

Leak test

Reference pressure checking

Monitoring vacuum pressure

93

Technical specifications

 Sensor heads
Type

Standard ±1bar (±100kPa )

Model no.

DPH-101

DPH-101-M3

DPH-101-M5

Positive pressure +1bar (+1.0MPa)

DPH-102

DPH-102-M5

DPH-103

Vacuum pressure ­1bar (-100kPa)
DPH-103-M3

DPH-103-M5

Type of pressure

Gauge pressure (note 1)

Rated pressure

­1 to +1bar (-100.0 to +100.0kPa)

0 to 10bar (0 to +1.0MPa)

0 to -1bar (0 to -100.0kPa)

Pressure resistance

5bar (500kPa)

15bar (1.5MPa)

5bar (500kPa)

Applicable fluid

Air, non-corrosive gas

Power supply

12 to 24VDC ±10%

Analog voltage output

Output voltage: 1 to 5V (overrated pressure range)

Protection

IP40 (IEC)

Ambient temperature
Pressure port Rated current consumption (without load) Material
Connection method

0 to +50°C
DPH-10p: R1/8 male thread + M5 female thread, DPH-10p-M3: M3 male thread (for installing gasket) DPH-10p-M5: M5 male thread (for installing gasket)
Max. 15mA
Front case: PBT, Rear case: PBT (glass fiber reinforced), Pressure port: stainless steel (SUS303), O-ring: NBR, Pressure element silicon diaphragm, PPS
Cable, 2m with attached connector

Dimensions (HxWxD)

23x13.2x 23.4mm 17x10x 20.5mm 17.5x10x 20.5mm 23x13.2x 23.4mm 17.5x10x 20.5mm 23x13.2x 23.4mm 17x10x 20.5mm 17.5x 10x 20.5mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
DPC-100/ DPH-100

Accessories

Connector (e-CON): 1 pc.

 Controller
Type Model no. Applicable sensor head Rated pressure Power supply Output
Power consumption
Ambient temperature
Material
Protection Connection method Dimensions (HxWxD) Accessories Notes: 1.) Reference pressure 1atm 2.) CN-66A-C2 cable 2m is included in delivery

NPN output

PNP output

DPC-101

DPC-101-P

DPH-101p, DPH-102p, DPH-103p
Compound pressure type: ­1 to +1bar (-100.0 to +100.0kPa) Positive pressure: 0 to 10bar (0 to +1.0MPa) Vacuum pressure: 0 to ­1bar (0 to -100.0kPa)
12 to 24VDC ±10%

PNP or NPN open-collector transistor, max. 100mA
Normal operation: max. 960mW (Current consumption max. 40mA at 24V supply voltage) ECO mode (STD): max. 720mW (Current consumption max. 30mA at 24V supply voltage) ECO mode (FULL): max. 600mW (Current consumption max. 25mA at 24V supply voltage)
Excluding the current consumption of sensor head and analog output current
­10 to +50°C
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic,
Threaded part: Brass (nickel plated) Switch part: Silicon rubber
IP40 (IEC)

Connector (note 2)

30x30x29.2mm
CN-66A-C2 Cable (2m) with attached connector Pressure unit label: 1 set

94 PRESSURE & FLOW SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Head-separated sensor
The sensor head is very flexible and can be used with or without the control unit. High-precision measuring is possible with an analog current output of 1 to 5V and extremely accurate detection of 1% F.S.

DPC-L100/ DPH-L100

 Stainless steel construction
The enclosure is made of stainless steel and hence suitable in a wide range of appliatons. An oil-less, hermetically enclosed diaphragm prevents the fluids from being polluted. An integrated throttle controls the pressure and prevents damage by excess pressure.

DPC-L100 / DPH-L100
Powerful and simple high-precision detection of fluid and air pressure

Main circuit
Piezo-electric conversion

Stainless steel diaphragm (Integrated pressure transducer) SUS630
Pressure port SUS304

 Wide pressure ranges
Various sensor heads for different pressure ranges from vacuum pressure to positive pressure (up to 500bar/50MPa) are available. With the control unit, the pressure range can be output linearly as voltage or current.

Throttle SUSXM7

DPH-L113V -0.1 to +1.0 MPa DPH-L113
0 to +1.0 MPa
DPH-L133
0 to +3.5 MPa
DPH-L114
0 to +10 MPa
DPH-L154
0 to +50 MPa

Color continuum

For use with pressurized air and other media (air mixed with water or oil)

Air Water

For use with pressurized fluid and other media (water or chemical solutions)

Oil
For use with pressurized oil and other media

­0.1 0

+1

+3.5 Pressure range (MPa)

+10

+50

95

Typical applications
Transport of glass sheets after washing (pressurized air containing water droplets)

Management of plastic filling machine pressure (pressurized fluid)

Management of press pressure (pressurized oil)

Technical specifications

 Sensor heads

Type Model no. Rated pressure Applicable fluid Power supply Analog voltage output Response time Medium temperature range Pressure port Protection Ambient temperature Material Connection method Dimensions (ØxD) Accessories

Compound pressure type

Positive pressure

DPH-L113V

DPH-L113

DPH-L133

DPH-L114

DPH-L154

-1 to +10bar (-0.1 to +1.0MPa)

0 to +10bar (0 to +1.0MPa)

0 to +35bar (0 to +3.5MPa)

0 to +100bar (0 to +10.0MPa)

0 to +500bar (0 to +50.0MPa)

Gases and fluids that do not corrode SUS630, SUS304, or SUSXM7

9 to 36VDC

1 to 5VDC overrated pressure range, Accuracy (note): ±1% F.S. (at 23±2°C)

Max. 1ms

­20 to +70°C

­20 to +125°C

R1/4 male thread ( (throttle embedded)

IP67 (IEC)

­20 to +70°C

­20 to +80°C

Diaphragm: stainless steel (SUS630); mounting threaded part: stainless steel (SUS304), Throttle: Stainless steel (SUSXM7)

Cable with connector enclosed, 2m

24.3x73mm

e- CON connector 1pc.

Note: Accuracy including linearity, hysteresis and repeatability
 Controller

Type

NPN output

DPC-L101

Model no.

PNP output

DPC-L101P

Applicable sensor head

DPH-L113V

DPH-L113

DPH-L133

DPH-L114

DPH-L154

Rated pressure

-1 to +10bar (-0.1 to +1.0MPa)

0 to +10bar (0 to +1.0MPa) 0 to +35bar (0 to +3.5MPa)

0 to +100bar (0 to +10.0MPa)

0 to +500bar (0 to +50.0MPa)

Power supply

12 to 24VDC ±10%

Output Analog voltage output Response time

2 PNP or NPN open-collector transistors, max. 50mA

Output voltage 1 to 5V Zero point: within 1V ± 5% F.S. (note 1)
Span: 4V ± 0.5% F.S. Linearity: within ±0.1% F.S. Load impedance: approx. 1k

Output current: 4 to 20mA Zero point: within 4mA ±1.0% F.S. (note 2)
Span: 16mA ± 1.5% F.S. Linearity: within ±0.1% F.S. Load resistance: max. 250k

5ms,10ms, 25ms, 50ms, 100ms, 250ms, 500ms, 1000ms, 5000ms selectable by key operation

Protection

IP40 (IEC)

Ambient temperature

­10 to +50°C

Material

Enclosure: PBT, LCD display: acrylic; Mounting threaded part: brass (nickel plated), Switch part: silicone rubber

Connection method

Connector

Dimensions (HxWxD)

30x30x25.5mm

Accessories

CN-66A-C2 Cable, 2m with connector attached, Pressure unit label: 1 set

Notes: 1.) DPH-L113V: Zeropoint within 1.364V ± 0.5% F.S. 2.) DPH-L113V: Zeropoint within 5.455mA ±1.0% F.S.

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
DPC-L100/ DPH-L100

96 PRESSURE & FLOW SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

FM-200
Flow sensor with dual display

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Easy-to-read, 2-color display with sub display
The 2-color digital display lets you check the operation status of the FM-200 at a glance. The use of color makes it easy to distinguish between measurement values and functionality.

 High precision of ±3% F.S.
Micro Electro Mechanical System (MEMS) technology allows the FM-200 sensor to be mounted on a silicon sensor chip. The advantages
are as follows: an extremely small heat capacity, a high precision of ±3% F.S., and a high-speed response time. Two temperature sensors, one on either side of the heater, detect heat distribution and make bidirectional detection possible.

 One sensor for both intake and exhaust
A single sensor can detect flows bidirectionally, or the forward or reverse direction only, making it suitable for a variety of applications.

 Analog voltage output
1 to 5V analog voltage output is incorporated.

 Integrated output and pulse output mode incorporated
The FM-200 series can control and manage flows for a wide variety of applications. The integrated output mode will turn the output ON or OFF at the specified integrated value, allowing you to control air blowing volumes, for example. In pulse output mode, a pulse is generated once at each specified integrated value, allowing you to monitor the amount of air consumed, for example with an EcoPOWER METER.
 Integrated value reset function
In integrated mode, values accumulate over time. As soon as the limit is reached, the digital output is set. This limit value can also be reset by an external input.
 Rattle prevention function
To prevent rattling from rapid changes in flow or from noise, the response time can be set to one of seven steps, from 50ms to approximately 1500ms. The display update period can be changed to 250ms, 500ms or 1000ms in order to eliminate flickering.
 ECO mode
In ECO mode, the backlight is turned off after approximately one minute if no operation occurs to reduce power consumption.

Typical applications

Checking suction

Checking seating

Monitoring air blowing and purge gas

97

Technical specifications

Type

Model no.

PNP output NPN output

Full scale flow rate

Display range

Setting and display resolution

Rated pressure

Pressure resistance

Applicable fluid

Linearity

Response time

Power supply

Output

Output modes

Analog voltage output Rated current consumption (without load) Protection Ambient temperature Material Connection method Dimensions (HxWxD) Temperature characteristics Port size

Type

Model no.

PNP output NPN output

Full scale flow rate

Display range

Setting and display resolution

Rated pressure

Pressure resistance

Applicable fluid

Linearity

Response time

Power supply

Output

Output modes

Analog voltage output

Rated current consumption (without load)

Protection

Ambient temperature

Material

Connection method

Dimensions (HxWxD)

Temperature characteristics

Port size

Accessories

Plastic housing

FM-252-4-P

FM-213-4-P

FM-253-4-P

FM-214-4-P

FM-254-8-P

FM-215-8-P

FM-252-4

FM-213-4

FM-253-4

FM-214-4

FM-254-8

FM-215-8

500ml/min

1.0l/min

5l/min

10l/min

50l/min

100l/min

±9999999ml

±99999.99l

±999999.9l

1ml/min

0.01l/min

0.1l/min

­0.9 to +7bar (­0.09 to +0.7MPa)

10bar (1.0MPa)

Clean air, compressed air, nitrogen gas

3%F.S.

50ms to 1.5s selectable

12 to 24VDC ±10%

PNP or NPN open-collector transistor, max. 50mA

Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode

1.0 to 5.0V

Normal mode: max. 60mA, ECO mode: max. 40mA

IP40 (IEC) 0 to +50°C
Plastic Cable with connector enclosed, 1m 37x55x17mm Within ±0.2% F.S./°C (+15°C to +35°C) ø4 push-in

43x55x17mm ø8 push-in

Aluminum housing

FM-255-AR2-P

FM-255-AG2-P

FM-216-AR2-P

FM-216-AG2-P

FM-255-AR2

­

FM-216-AR2

­

500l/min

1000l/min

±999999.9l

1l/min

­0.9 to +7bar (-0.09 to +0.7MPa)

10bar (1.0MPa)

Clean air, compressed air, nitrogen gas

3%F.S.

50ms to 1.5s selectable

12 to 24VDC ±10%

PNP or NPN open-collector transistor, max. 50mA

Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode

1.0 to 5.0V

Normal mode: max. 60mA, ECO mode: max. 40mA

Rc½ female thread

IP40 (IEC)

0 to +50°C

Resin/Aluminum body type

Cable with connector enclosed, 1m

50x80x30mm

Within ±0.2% F.S./°C (+15°C to +35°C)

G½ female thread

Rc½ female thread

CN-F15-C1 cable, 1m with attached connector

G½ female thread

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
FM-200

98 INDUCTIVE PROXIMITY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors



High Response frequency

Ionizers/ Electrostatic
Sensors Accessories
GX-300

The GX-303S boasts a response frequency of 5kHz and realizes high speed response.The response frequency of other sensor models has been also improved by up to 4 times as compared to our conventional models. Since the GX-300 series responds quickly to sensor ON/ OFF judgement, it works well with a high-speed application and contributes to the reduction of equipment cycle time.

GX-300
Cylindrical Inductive sensor with IO-Link

Type

Response frequency of our conventional model

ø3mm
ø4 mm* Conventional model: ø3.8 / ø4.4mm
ø5.4 mm

-- 1kHz 1.5kHz

Significant improvement over
conventional models!
4 times
2.7 times

Response frequency of GX-300 standard sensing range type
5kHz (GX-303S)
4kHz (GX-304S)
4kHz (GX-305S)

M5 threaded

1kHz

4 times

4kHz (GX-305M)

M8 threaded

1kHz

2 times

2kHz (GX-308M)

M12 threaded

450Hz

3.3 times

1,500Hz (GX-312M)

M18 threaded

300Hz

2 times

600Hz (GX-318M)

 Indicator visible 360 degrees
In the small-diameter type sensors, the indicator light is visible at 4 locations. In the M8 and larger threaded type sensors, the high-brightness indicator and the resin containing dispersing agent allow the confirmation of the indicator from any angle to facilitate the cumbersome adjustment of installation position. The green indicator flashes during IO-Link communication.

 Extensive line up
The GX-300 series includes 310 different sensor models. We offer various types of sensor models such as the cable type (cable length: 2m or 5m) connector type and pigtailed type. Furthermore, we can supply bending-resistant cable type models (cable length : 2m or 5m), which are suitable for installation on moving parts.

Small-diameter type
Indicator light visible at 4 locations

M8 / M12 / M18 / M30 threaded type
toryvdisiriebcletion

Cable type

Connector type

Pigtailed type

fro Imnadinca

99

 IOT ready
With the implemented IO-Link technology network integration is easy. The IO-Link models can be used as normal digital PNP output sensors or providing information about the sensor level
Typical applications
Positioning processing equipment

or the current sensor condition via IO-Link interface. This is perfect for predictive maintenance and applications with higher expectations.

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors

Dog GX-308MK

Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

Technical specifications

 DC 3-wire type (Small-diameter, shielded type)

Type

Model No. (note 2)

Normally Open
Normally closed

Rated sensing distance

Stable sensing distance (note 3)

Standard sensing object (note 7)

Hysteresis

Supply voltage (note 4)

Current consumption

Control output

Response Frequency (note 5)

Protection

Ambient temperature

Dimension (HxWxD)

Material

Connection method (note 6)

GX-303S-A- GX-303S-B-
0.8mm 0 to 0.56mm
3x3mm
5kHZ
Ø3x27.1mm

Non-threaded type GX-304S-A-

GX-305S-A-

GX-304S-B-

GX-305S-B-

1.0mm

1.2mm

0 to 0.84mm

0 to 0.7mm

4x4mm

5.4x5.4mm

Max. 15% of measurement distance

10-30V DC ±10% (note1)

max. 10mA

PNP / NPN open-collector transistor, 100mA (note2)

4kHz

IP67 (IEC)

-25 to +70°C

Ø4x25.1mm

Ø5.4x25.1mm

Case: Stainless steel (SUS303) [Brass (Nickel plated) for GX-305S], Sensing part: Heat-resistant ABS

Cable, 2m or 5m; M12 connector type; pigtail type

Threaded type GX-305M-A- GX-305M-B-
1.0mm 0 to 0.84mm
4x4mm
M8x25.1mm

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C 2.) Suffix -N =NPN type, Suffix -P = PNP type 3.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 4.) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained 5.) The response frequency is an average value. 6.) Suffix -C5 = 5m cable
Suffix -J = Pigtail 0.3m with M12 connector Suffix -Z = M12 connector type 7.) Standard sensing object = sheet steel, thickness: 1mm

GX-300

100 INDUCTIVE PROXIMITY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 DC 3-wire type (Shielded type)

Type
Model No. (note 2)
Rated sensing distance Stable sensing distance (note 3) Standard sensing object (note 7) Hysteresis Supply voltage (note 4) Current consumption Control output
Switching and communication line (C/Q) (note 8)
Response Frequency (note 5) Protection Ambient temperature Dimension (HxWxD)

Normally Open Normally closed
Communication specification Baud rate Process data Transmission cycle time

Material

Connection method (note 6)

GX-308M-A- GX-308M-B-
1.5mm 0 to 1.2mm
8x8mm
2kHZ M8x37.8mm

Threaded type

GX-312M-A-

GX-318M-A-

GX-330M-A-

GX-312M-B-

GX-318M-B-

GX-330M-B-

2.0mm

5mm

10mm

0 to 1.6 mm

0 to 4 mm

0 to 8mm

12x12mm

18x18mm

30x30mm

Max. 10% of measurement distance

10-30V DC ±10% (note1)

max. 16mA

PNP / NPN open-collector transistor, 200mA (note 2)

IO-Link specification V1.1

COM3 (230.4kbit/s)

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)

0.4ms

1.5kHz

0.6kHz

0.4kHz

IP67 (IEC)

-40 to +85°C

M12x47.1mm

M18x55.3mm

M30x60.3mm

Case: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-], Sensing part: Polybutylene terephthalate (PBT)

Cable, 2m or 5m; M12 connector type; pigtail type

GX-300

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C 2.) Suffix -N = NPN type, Suffix -P = PNP type 3.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 4.) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained 5.) The response frequency is an average value. 6.) Suffix -C5 = 5m cable / Suffix -J = Pigtail 0.3m with M12 connector / Suffix-Z = M12 connector type 7.) Standard sensing object = sheet steel, thickness: 1mm 8.) IO-Link type only integrated in Normally open and PNP types = GX-3M-A-P

 DC 3-wire type (Non-shielded type)

Type
Model No. (note 2)
Rated sensing distance Stable sensing distance (note 3) Standard sensing object (note 7) Hysteresis Supply voltage (note 4) Current consumption Control output
Switching and communication line (C/Q) (note 8)
Response Frequency (note 5) Protection Ambient temperature Dimension (HxWxD)

Normally Open Normally closed
Communication specification Baud rate Process data Transmission cycle time

Material

Connection method (note 6)

Threaded type

GX-308ML-A-

GX-312ML-A-

GX-318ML-A-

GX-308ML-B-

GX-312ML-B-

GX-318ML-B-

2.0mm

5.0mm

10mm

0 to 1.6 mm

0 to 4 mm

0 to 8 mm

8x8mm

12x12mm

18x18mm

Max. 10% of measurement distance

10-30V DC ±10% (note1)

max. 16mA

PNP / NPN open-collector transistor, 200mA (note 2)

IO-Link specification V1.1

COM3 (230.4kbit/s)

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)

0.4ms

1kHZ

0.8kHz

0.4kHz

IP67 (IEC)

-40 to +85°C

M8x37.8mm

M12x47.1mm

M18x55.3mm

Case:Nickel-plated brass [stainless steel (SUS303) for GX-308ML(K)-], Sensing part: Polybutylene terephthalate (PBT)

Cable, 2m or 5m; M12 connector type; pigtail type

GX-330ML-A- GX-330ML-B-
18mm 0 to 14.4 mm
30x30mm
0.1kHz M30x60.3mm

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C 2.) Suffix -N = NPN type, Suffix -P = PNP type 3.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 4.) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained 5.) The response frequency is an average value. 6.) Suffix -C5 = 5m cable / Suffix -J = Pigtail 0.3m with M12 connector / Suffix -Z = M12 connector type 7.) Standard sensing object = sheet steel, thickness: 1mm 8.) IO-Link type only integrated in Normally open and PNP types = GX-3ML-A-P

101

 DC 3-wire type (Shielded type, long sensing range)

Type Model No. (note 2)
Rated sensing distance Stable sensing distance (note 3) Standard sensing object (note 7) Hysteresis Supply voltage (note 4) Current consumption Control output
Switching and communication line (C/Q) (note 8)
Response Frequency (note 5) Protection Ambient temperature Dimension (HxWxD) Material Connection method (note 6)

Normally Open Normally closed
Communication specification Baud rate Process data Transmission cycle time

Threaded type

GX-308MK-A-

GX-312MK-A-

GX-318MK-A-

GX-330MK-A-

GX-308MK-B-

GX-312MK-B-

GX-318MK-B-

GX-330MK-B-

2.0mm

4.0mm

8mm

15mm

0 to 1.6mm

0 to 3.2mm

0 to 6.4mm

0 to 12mm

8x8mm

12x12mm

18x18mm

30x30mm

Max. 15% of measurement distance

10-30V DC ±10% (note1)

max. 16mA

PNP / NPN open-collector transistor, 200mA (note 2)

IO-Link specification V1.1

COM3 (230.4kbit/s)

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)

0.4ms

1.5kHZ

1.kHz

0.5kHz

0.25kHz

IP67 (IEC)

-40 to +85°C

M8x37.8mm

M12x47.1mm

M18x55.3mm

M30x60.3mm

Case: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-] Sensing part: Polybutylene terephthalate (PBT)

Cable, 2m or 5m; M12 connector type; pigtail type

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C 2.) Suffix -N = NPN type, Suffix -P = PNP type 3.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 4.) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained 5.) The response frequency is an average value. 6.) Suffix -C5 = 5m cable / Suffix -J = Pigtail 0.3m with M12 connector / Suffix -Z = M12 connector type 7.) Standard sensing object = sheet steel, thickness: 1mm 8.) IO-Link type only integrated in Normally open and PNP types = GX-3MK-A-P

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
GX-300

 DC 3-wire type (Non-shielded type, long sensing range)

Type
Model No. (note 2)
Rated sensing distance Stable sensing distance (note 3) Standard sensing object (note 7) Hysteresis Supply voltage (note 4) Current consumption Control output
Switching and communication line (C/Q) (note 8)
Response Frequency (note 5) Protection Ambient temperature Dimension (HxWxD) Material Connection method (note 6)

Normally Open Normally closed
Communication specification Baud rate Process data Transmission cycle time

Threaded type

GX-308MLK-A-

GX-312MLK-A-

GX-318MLK-A-

GX-330MLK-A-

GX-308MLK-B-

GX-312MLK-B-

GX-318MLK-B-

GX-330MLK-B-

4mm

8mm

16mm

30mm

0 to 3.2 mm

0 to 6.4 mm

0 to 12.8 mm

0 to 24 mm

12x12mm

24x24mm

48x48mm

90x90mm

Max. 15% of measurement distance

10-30V DC ±10% (note1)

max. 16mA

PNP / NPN open-collector transistor, 200mA (note 2)

IO-Link specification V1.1

COM3 (230.4kbit/s)

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)

0.4ms

1.5kHZ

1.kHz

0.5kHz

0.25kHz

IP67 (IEC)

-40 to +85°C

M8x37.8mm

M12x47.1mm

M18x55.3mm

M30x82.3mm

Case: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-], Sensing part: Polybutylene terephthalate (PBT)

Cable, 2m or 5m; M12 connector type; pigtail type

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C 2.) Suffix -N = NPN type, Suffix -P = PNP type 3.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 4.) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained 5.) The response frequency is an average value. 6.) Suffix -C5 = 5m cable / Suffix -J = Pigtail 0.3m with M12 connector / Suffix -Z = M12 connector type 7.) Standard sensing object = sheet steel, thickness: 1mm 8.) IO-Link type only integrated in Normally open and PNP types = GX-3MLK-A-P

102 INDUCTIVE PROXIMITY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

GX-M
Cylindrical inductive sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 2- and 3-wire types
The GX-M series consists of 2- and 3-wire types. The 3-wire type is available as a shielded or non-shielded type. The 2-wire type is available as a shielded type and long-range type (up to 15mm). Reduced wiring efforts and space-saving installation reduce costs.

GX-M  Various cylinder and thread types
M8, M12, M18 and M30 types means the GX-M series can be used to solve a wide range of automation task. Space-saving, case-by-case integration in production lines, testing and manual work stations.

 Several connection possibilities
You can connect the GX-M sensor with either a 2m cable or M12 plug-in connector.
 Special applications
IP69K (DIN) and IP68 (IEC) types are also available, e.g. for use in machine systems, i.e. the food processing machinery.

Typical applications

Control drilling depth

Detect how far press lowers

Count parts

Control position of components

103

Technical specifications

 3-wire type

Type Model no. Rated sensing distance (note 4)

GX-M8 (-A/ -B)(-P) (-Z) (note 1,2,3)
1.5mm ±10%

Shielded

GX-M12 (-A/ -B) (-P)(-Z)

GX-M18 (-A/ -B) (-P)(-Z)

2mm ±10%

5mm ±10%

GX-M30 (-A/ -B) (-P)(-Z)
10mm ±10%

GX-MK12 (-A/ -B) (-P)(-Z)
7mm ±10%

Unshielded
GX-MK18 (-A/ -B) (-P)(-Z)
12mm ±10%

Stable sensing distance (note 5)

0 to 1.2mm

0 to 1.6mm

0 to 4mm

0 to 8mm

0 to 5.6mm

0 to 9.6mm

Standard sensing object (note 6)

8x8mm

12x12mm

18x18mm

30x30mm

24x24mm

24x24mm

Hysteresis

Max. 15% of measurement distance

Repeatability

Along sensing axis: max. 5% of measurement distance

Power supply

12 to 24VDC ±10%

Output

Open collector transistor max. 200mA (note 2)

Output operation

Normally closed (N.C.) or Normally open (N.O.) (note 1)

Switching frequency

5kHz

5kHz

2kHz

1kHz

2.5kHz

1kHz

Protection

IP67 (IEC)

IP69K (DIN), IP68 (IEC) 2m cable type; IP67 (IEC) M12 connector type

Ambient temperature

­25 to +70°C

Material

Enclosure: Brass (nickel plated), Sensing part: PPS (polyphenylsulfide)

Connection method

Cable, 2m or M12 plug-in connector type (note 3)

Dimensions (ØxL)

2m cable
M12 connector

M8x33mm M8x45mm

M12x35mm M12x50mm

M18x39mm M18x50mm

M30x43mm M30x55mm

M12x55mm M12x66mm

M18x60mm M18x72mm

Accessories

Nuts 2 pcs.

Notes: 1.) Suffix-A = Normally open type, suffix B= Normally closed type; i.e. GX-M8B 2.) Suffix-P = PNP type, without suffix = NPN type; i.e. GX-M8B 3.) Without suffix = 2m cable, suffix -Z = M12 connector type; i.e. GX-M8B-P-Z 4.) The specified rated sensing distance refers to the standard sensing object 5.) The specified stable sensing distance is the range in which the sensor works reliably even in case of deviations in temperature or voltage 6.) Standard sensing object = sheet steel, thickness: 1mm

GX-MK30 (-A/ -B) (-P)(-Z)
22mm ±10% 0 to 17.6mm
45x45mm
0.5kHz
M30x63mm M30x74mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
GX-M

 2-wire type

Shielded

Type

Standard sensing distance

Large sensing distance

Model no.

GX-M8(-A/-B)-U (note 1, 2)

GX-M12(-A/-B)U (-Z)

GX-M18(-A/-B)U (-Z)

GX-M30(-A/-B)U (-Z)

GX-ML8(-A/-B)-U

GX-ML12(-A/-B)U (-Z)

GX-ML18(-A/-B)U (-Z)

GX-ML30 (-A/-B)U (-Z)

Rated sensing distance (note 3)

1.5mm ±10%

2mm ±10%

5mm ±10%

10mm ±10%

2.5mm ±10%

4mm ±10%

8mm ±10%

15mm ±10%

Stable sensing distance (note 4)

0 to 1.2mm

0 to 1.6mm

0 to 4mm

0 to 8mm

0 to 2mm

0 to 3.2mm

0 to 6.4mm

0 to 12mm

Standard sensing object (note 5)

8x8mm

12x12mm

18x18mm

30x30mm

8x8mm

12x12mm

18x18mm

30x30mm

Hysteresis

Max. 15% of measurement distance

Repeatability

Along sensing axis: max. 5% of measurement distance

Power supply

12 to 24VDC ±10%

Output

Non-contact DC 2-wire type, sink current 1.5 to 100mA, residual voltage max 4.2V (note 6)

Output operation

Normally closed (N.C.) or Normally open (N.O.) (note 1)

Switching frequency

1kHz

1kHz

1.2kHz

1.3kHz

1.1kHz

1.3kHz

1.5kHz

0.8kHz

Protection

IP67 (IEC)

IP69K (DIN), IP68 (IEC) 2m cable type; IP67 (IEC) M12 connector type

Ambient temperature

­ 25 to +70°C

Material

Enclosure: Brass (nickel plated), Sensing part: PPS (polyphenylsulfide)

Connection method

Cable, 2m

Cable, 2m or M12 plug-in connector type (note 2)

Cable, 2m

Cable, 2m or M12 plug-in connector type (note 2)

Dimensions (ØxL)

2m cable
M12 connector

M8x33mm ­

M12x35mm M12x50mm

M18x39mm M18x50mm

M30x43mm M30x55mm

M8x33mm ­

M12x35mm M12x50mm

M18x39mm M18x50mm

M30x43mm M30x55mm

Accessories

Nuts 2 pcs.

­

Notes: 1.) Suffix-A = Normally open type, suffix B= Normally closed type; i.e. GX-M8B-U 2.) Without suffix = 2m cable, suffix -Z = M12 connector type; i.e. GX-M8B-P-Z 3.) The specified rated sensing distance refers to the standard sensing object 4.) The specified stable sensing distance is the range in which the sensor works reliably even in case of temperature or voltage deviations 5.) Standard sensing object = sheet steel, thickness: 1mm 6.) If you extend the cable residual voltage may rise

104 INDUCTIVE PROXIMITY SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

GX-F/H
Stable sensing of work pieces

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Environmental resistance
This sensor has a long stable sensing range. It is easy to install.
> IP68g protection: water and oil-resistant > Space-saving installation > A metal sleeve ensures a secure installation

The new, integrated construction method improves environmenGX-F/H tal resistance performance.

 The LED indicators are easy to see
A prism with a wide field of view has been developed, thereby greatly improving the visibility of the operation indicators.
 Stable detection
> Large sensing range > Max. deviation at max. sensing range: ±8% > Max. deviation with temperature changes: ±8%

Typical applications
Checking up/down operation of compact molding equipment

Sensing presence of metallic objects on a part feeder

Positioning metal pallets

Muting control with light curtains

Shock resistance: 5000G

Vibration resistance: 500Hz

105

Technical specifications

Model no.

Side sensing Top sensing

Max. operating distance (note 4)
Stable sensing distance (note 5)
Standard sensing object (note 6)

Repeatability

GX-F6 (-A/ -B)(-I)(-P) (note 1,2,3)
GX-H6 (-A/ -B)(-I)(-P)
1.6mm ±8%
0 to 1.3mm
12x12mm

GX-F8 (-A/ -B)(-I)(-P) GX-H8 (-A/ -B)(-I)(-P)
2.5mm ±8% 0 to 2.1mm 15x15mm

GX-F12 (-A/ -B)(-I)(-P) GX-H12 (-A/ -B)(-I)(-P)
4mm ±8% 0 to 3.3mm 20x20mm Min. 0.04mm

GX-F15(-A/ -B)(-I)(-P) GX-H15 (-A/ -B)(-I)(-P)
5mm ±8% 0 to 4.2mm 20x20mm

GX-FL15 (-A/ -B)(-I)(-P) GX-HL15 (-A/ -B)(-I)(-P)
8mm ±8% 0 to 6.7mm 30x30mm

Interference prevention

Alternate frequency (note 2)

Power supply

12 to 24VDC +10% / ­15%

Output

PNP / NPN open-collector transistor, 100mA (note 3)

Output operation

Normally closed (NC) or Normally open (NO) (note 1)

Switching frequency

400Hz

500Hz

250Hz

150Hz

Protection

IP68 (IEC)

Ambient temperature

­25 to +70°C

Material

Enclosure: PBT, display: polyester

Connection method

Cable, 1m

Dimensions (HxWxD)

Side sensing Top sensing

6x6x24.5mm 6x6x25mm

7.4x8x23mm 8.2x8x25mm

7.1x12x27.8mm 12x12x27.4mm

Notes: 1.) Suffix-A = Normally open type, suffix B= Normally closed type; i.e. GX-F6B 2.) Suffix-I = Alternate frequency type (interference prevention) i.e. GX-F6BI 3.) Without suffix = NPN type, P = PNP type; i.e. GX-F6BI-P 4.) The specified rated sensing distance refers to the standard sensing object 5.) The specified stable sensing distance is the range in which the sensor works reliably even in case of temperature or voltage deviations 6.) Standard sensing object = sheet steel, thickness: 1mm

8x15x31.5mm 16.5x15x29.5mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
GX-F/H

106 MEASUREMENT SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

HG-S
Slim and robust contact measurement sensor

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors Ionizers/
Electrostatic Sensors
Accessories
HG-S

 Larger measurement range
The new sensor head HG-S1032 has a measurement range of 32mm with an indication accuracy of 3µm. All types are equipped with two plain bearings, one at the top and one at the bottom. The sensor can withstand more than 100 million sliding operations under application of lateral load (reference value). The two plain bearings increase the resistance to mechanical stress from the side and ensure the accuracy of measuring results even under lateral load.

Lateral load is generated when the sensor is positioned at an angle or the workpiece becomes tilted.

F
Measurement of workpiece not securely held by the jig

Lateral load
F = Force

Typical applications
Coupling assembly inspection

Transmission parts height measurement

 Spindle stopper aginst damage

Even when a sudden upward thrust impact Spindle stopper
occurs, the resulting load is applied only to

the lower section of the sensor unit because a

spindle stopper minimizes the impact on the

glass scales. Additionally an alarm can be set

to notify the user of an upward thrust (stroke)

that exceeds the set level. This allows you to

conduct a preventive maintenance before the

sensor head generates a malfunction.



 Easy-to-understand 2-line digital display
The 2-line digital display simultaneously shows head measurement (measured value) and judgment value (calculated value). The highcontrast LCD provides sharp and clear indications and offers a wide viewing angle. Secondary display line: Displays sensor head measurement and other data. Main display line: displays judgment value.


1.) Dual display for more flexibility
2.) Copy function from master to slave units

 Serial connection of up to 15 slave units
One master unit can be connected in series with up to 15 slave units in any order. This allows easy multi-point calculations. End plates (optional) must be mounted on both sides of the controller after the connection of slave units.

Flat screen flatness measurement

107

Technical specifications
 Sensor heads

Type Model no. Measurement range
Measuring force (note 2, note 3)

Downward mount
Upward mount
Side mount

Standard type HG-S1010
Max. 1.65N,1.1N (note 4)
Max. 1.35N, 0.85N (note 4)
Max. 1.5 N, 0.95N (note 4)

General purpose Low measuring force
type HG-S1010R
Max. 0.35N, 0.3N (note 4)
­
Max. 0.25N, 0.2N (note 4)

NEW

Air driven type

Standard type

HG-S1010-AC

HG-S1110

10mm (note 1)

0.14 to 0.16 MPa Dependent on ap-
plied pressure

Max. 1.65N,1.1N (note 4)
Max. 1.35N, 0.85N (note 4)
Max. 1.5 N, 0.95N (note 4)

High precision Low measuring force
type HG-S1110R
Max. 0.35N, 0.3N (note 4)
­
Max. 0.25N, 0.2N (note 4)

NEW
Air driven type HG-S1110-AC
0.14 to 0.16 MPa Dependent on ap-
plied pressure

General purpose
Standard type
HG-S1032 32mm
Max. 2.97N,1.90N (note 4)
Max. 2.09N, 1.19N (note 4)
Max. 2.53 N, 1.50N (note 4)

Resolution

0.5µm

0.1µm

0.5µm

Accuracy

Full range: max. 2.0m Narrow range: max. 1.0m (any 60m)

Full range: 2,0 m, Limited range: 1,0 m

Full range: max. 1.0m Narrow range: max. 0.5m (any 60m)

Full range: 1,0 m Limited range: 0,5 m

Full range: max. 3.0 m
Narrow range: max. 2.0m (any 60m)

Protection

IP67 (IEC, note 5)

IP67 (IEC) (Note 8)

IP67 (IEC, note 5)

IP67 (IEC) (Note 8) IP67 (IEC, note 5)

Ambient temperatur Material Connection method

Body: zinc, holder: stainless steel; spindle: tool steel; probe (note 6): ceramic;
rubber bellows: NBR (black)

Body: zinc, holder: stainless steel, spindle: tool steel, probe (note 7): ce-
ramic, Air tube clamp: S60CM

-10 to +55°C
Body: zinc, holder: stainless steel; spindle: tool steel; probe (note 6): ceramic;
rubber bellows: NBR (black)
Connector (note 7)

Body: zinc, holder: stainless steel, spindle: tool steel, probe (note 7): ce-
ramic, Air tube clamp: S60CM

Body: zinc, holder: stainless steel; spindle: tool steel; probe (note 6): ceramic; rubber bellows: NBR (black)

Dimensions (HxWxD)

135.5x11x18mm

125x11x18mm

135.5x11x18mm

125x11x18mm

217x17.5x27mm

Notes: 1.) 5 to 10mm range when low measurement force type (HG-S1010R / HG-S1110R / HG-S1032) is mounted in upward mount 2.) Measured at an ambient temperature of +20°C 3.) In the case of low measuring force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows 4.) Typical value near center of measurement 5.) Excludes damage and deterioration to rubber bellows due to external causes 6.) Different probes (optional) are also available 7.) Please order sensor head connection cable seperately 8.) Seal Cap has to be applied
 Controllers

Type

Master unit

Slave unit

High-performance type

Standard type

Model no.

NPN output PNP output

HG-SC101 HG-SC101-P

HG-SC111 HG-SC111-P

HG-SC112 HG-SC112-P

Supply voltage

24V DC ±10% (note1)

Current consumption (note 2)

Max. 70mA when sensor head is connected

Response time

3ms, 5ms, 10ms, 100ms, 500ms, 1000ms switching type

Control output

NPN or PNP open collector transistor, max. 50 mA

Analog output (note 3)

4-20mA

Protection

IP40 (IEC)

Ambient temperature

-10 to +50°C

Dimension (HxWxD)

43.1x86x21.1mm

Material

Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal

Connection method

Cable, 2m

Notes: 1.) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20°C 2.) Current consumption does not include analog current output 3.) Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values
 Sensor head connection cable

Type Model no.

CN-HS-C3

Straight connector CN-HS-C7

CN-HS-C7

CN-HS-C3L

L-shaped connector CN-HS-C7L

CN-HS-C20L

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
HG-S

Length

3m

7m

20m

3m

7m

20m

108 MEASUREMENT SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

HG-C
Reliable detection with repeatability of 10m

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Equipped with 0-5V analog output
The sensor not only indicates measured values in mm, but also outputs analog voltage. The data can be used for various calculations and storage (logging) when the output is sent to a PLC + analog unit.

 Configurable external input
The external input can be configured to perform one of four functions: "zero set", "teaching", "emission stop" and "selecting trigger function".

Distance Distance Distance

 Teaching & window comparator mode
HG-C
1-point teaching
Set to Light-ON

TEACH 

OFF
Threshold

ON

Reference point

Threshold
OFF

2-point teaching
TEACH 
TEACH 

Set to Light-ON
OFF
Threshold
ON
Threshold
OFF

3-point teaching

TEACH 

TEACH 

TEACH 
OFF
ON
OFF

Set to Light-ON
Ref. point 3
Threshold Ref. point 2 Threshold Ref. point 1

Object present

Lower limit Upper limit

Object A Object B Object C

Perform 1-point teaching and the threshold range is set for the distance from the reference surface of the object to be detected.

Press TEACH once for the lower (first point) and once for the upper limit (second point). This is useful for detecting objects at different distances.

This is the method to set the threshold range by conducting the teaching at 3 points (detecting object A, B and C). After teaching, the reference points are automatically sorted in ascending order (reference point 1, 2 and 3). The thresholds are set at the midpoints between reference point 1 and 2, and 2 and 3, respectively. This is useful for detecting objects at different distances.

Typical applications

Measuring the hoop slack

Checking for presence of O ring

Controlling the height of a robot Controlling the dispenser head height

109

Technical specifications

Measurement center type NPN output PNP output Applicable standards Sensing range Repeatability Linearity Beam diameter Supply voltage Control output
Output operation Short circuit protection

30mm HG-C1030 HG-C1030-P
30±5mm 10m
Approx. 50m

Analog output

Response time Degree of protection Ambient temperature Ambient humidity Ambient illumination Cable Material Dimensions (HxWxD)

50mm

100mm

200mm

HG-C1050

HG-C1100

HG-C1200

HG-C1050-P

HG-C1100-P

HG-C1200-P

Conforming to EMC Directive and FDA Standard

50±15mm

100±35mm

200mm ±80mm

30m

70m

200m

±0.1% F.S.

±0,2% F.S.

Approx. 70m

Approx. 120m

Approx. 300m

12 to 24V DC ±10%

PNP or NPN open-collector transistor

Either Light-ON or Dark-ON

Incorporated (auto-reset)

Voltage output: 0 to 5V (at alarm: +5.2V). Load impedance: 100 Analog current output: Output range: 4 to 20mA (at alarm: 0mA)
Output impedance: 300 or less

400mm HG-C1400 HG-C1400-P
400mm ±200mm 300m (200-400mm) 800m (400-600mm) ±0,2% F.S. (200-400mm) ±0,3% F.S. (400-600mm)
Approx. 500m

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

Switchable between high speed (1.5ms), standard (5ms), and high precision (10ms)

HG-C

IP67 (IEC)

-10 to +45°C (no dew condensation or icing allowed), storage: -20 to +60°C

35 to 85% RH, at storage: 35 to 85% RH

3000x max. (Illumination level of light receiving surface under incandescent light)

5-core cable, 2m

Enclosure: die-cast aluminum, front cover: acrylic

44x20x25mm

110 MEASUREMENT SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

HL-G1
Precision laser displacement sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 All-In-One Concept
All processing electronics are incorporated in a robust sensor housing. All settings can be made directly on the sensor. A 7-segment LED-display makes it easy to configure sensor operation while checking displacement values.

 User-friendly
The HL-G1 series can be operated directly, by touch terminal (GT02/GT12 series) or Windows software via RS-422/RS-485.

 Compact and lightweight body
HL-G1 With its lightweight plastic body, weighing just 70g and dimensions of 20.4 x 60 x 57mm, it is easy to integrate the sensor in machines and production lines where space is tight.

 Extended product range
With the extension of the HL-G1 series it is now possible to measure on specular surfaces with a high accuracy. Models with different measurement distances up to 82mm are available. Suitable applications can be for example in the semiconductor industry with specular wafer surfaces or other polished metal parts.

Typical applications
Control of dispenser height
Dispenser

Detection of aluminum wheel grooves

HL-G1

Measuring sheet slack and thickness

Measuring the eccentricity of a metal shaft

111

Technical specifications

 Standard type

Type Model no. Sensing range Emission spot size Power supply Analog voltage output Response time Resolution Linearity Emitting element Output Protection Ambient temperature Material Connection method Dimensions (HxWxD) Accessories

HL-G103-A-C5 30±4mm 0.1x0.1mm
0.5m

Diffuse reflective type

Specular reflective type

HL-G105-A-C5

HL-G108-A-C5

HL-G112-A-C5

HL-G125-A-C5

HL-G103-RA-C5 HL-G105-RA-C5

HL-G-RA-C5

50±10mm

85±20mm

120±60mm

250±150mm

26.3±2mm

47.3±5mm

82.9±10mm

0.5x1mm

0.75x1.25mm

1.0x1.5mm

1.75x3.5mm

0.1x0.1mm

0.2x0.2mm

24V DC ±10%

0 to 10V / 4 to 20mA

200s, 500µs, 1ms, 2ms (selectable)

1.5m

2.5m

8m

20m

0.5m

1.5m

2.5m

±0.1%F.S.

±0.3%F.S.

±0.2%F.S.

Red laser diode, 655nm (class 2)

PNP or NPN open-collector transistor, max. 50mA (selection by wiring)

IP67 (IEC)

­10 to +45°C

Enclosure: PBT / Front cover: Acrylic / Cable: PVC

Cable, 5m

60x20.4x57mm

Warning label (English): 1 set

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

 Multifunction type

Type

Diffuse reflective type

Specular reflective type

Model no.

HL-G103-S-J

HL-G105-S-J

HL-G108-S-J

HL-G112-S-J

HL-G125-S-J

HL-G103-RS-J

HL-G105-RS-J

HL-G108-RS-J

Sensing range

30±4mm

50±10mm

85±20mm

120±60mm

250±150mm

26.3±2mm

47.3±5mm

82.9±10mm

Emission spot size

0.1x0.1mm

0.5x1mm

0.75x1.25mm

1.0x1.5mm

1.75x3.5mm

0.1x0.1mm

0.2x0.2mm

Power supply

24V DC ±10%

Analog voltage output

0 to 10V / 4 to 20mA

Interfaces

RS-485 / RS-422

Response time

200s, 500µs, 1ms, 2ms (selectable)

Resolution

0.5m

1.5m

2.5m

8m

20m

0.5m

1.5m

2.5m

Linearity

±0.1%F.S.

±0.3%F.S.

±0.2%F.S.

Emitting element

Red laser diode, 655nm (class 2)

Output

PNP or NPN open-collector transistor, max. 50mA (selection by wiring)

Protection

IP67 (IEC)

Ambient temperature

­10 to +45°C

Material

Enclosure: PBT / Front cover: Acrylic / Cable: PVC

Connection method

Cable with connector, 0.5m (note)

Dimensions (HxWxD)

60x20.4x57mm

Accessories

Warning label (English): 1 set

Note: Cable is not included in delivery. Please select under accessories (page 129)

HL-G1

112 MEASUREMENT SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Excellent basic performance
 Sampling rate 100kHz
The HDLC-CMOS sensors were developed especially for the HL-C2 series. The high-resolution chip together with a very short processing time enables maximum resolution and speed.

HL-C2  Resolution up to 0.01µm, linearity up to ±0.02%F.S.
Superior resolution of 0.01µm. Linearity of ±0.02%F.S. enabled by latest high resolution lens technology.

HL-C2
Ultra high-speed, precision laser displacement sensors
 Compact but with a wide array of functions
You can connect two sensor heads and a variety of devices to the ultra compact controller. Measurement values can be analyzed and displayed while the sensors are being controlled.

Typical applications
Measurement of the position of patterned glass

Control of the camera focus

Measurement of the shape of a camshaft

Measurement of the heights of chip parts

113

Specifications

 Sensor heads
Measuring range Model no. Type Measuring range Resolution Laser class Beam size Linearity Dimensions (HxWxD)

10±1mm

HL-C201F

HL-C201FE

HL-C201F-MK

HL-C201FE-MK

Small beam spot type

Linear beam spot type

10±1 mm

0.01m

0.25m

0.01m

0.25m

Class 1

Ø20m

20x700m

±0.02% F.S.

54x20x95mm

30±5mm

HL-C203F

HL-C203FE

HL-C203F-MK

HL-C203FE-MK

Small beam spot type

Linear beam spot type

30±5 mm (specular reflective mode 26.4±4.6mm)

0.025m

0.25m

0.025m

0.25m

Class 2

Ø30m

30x1200m

±0.03% F.S

80x26x70mm

Measuring range:
Model no.
Type Measuring range Resolution Laser class Beam size Linearity Dimensions

50±5mm

85±20mm

HL-C205B

HL-C205B-MK

HL-C205C

HL-C205C-MK

HL-C208B

HL-C208B-MK

HL-C208C

HL-C208C-MK

(HL-C205BE, note 1) (HL-C205BE-MK, note 1) (HL-C205CE, note 1) (HL-C205CE-MK, note 1) (HL-C208BE, note 1) (HL-C208BE-MK, note 1) (HL-C208CE, note 1) (HL-C208CE-MK, note 1)

Spot type

Linear beam spot type

Spot type

Linear beam spot type

Spot type

Linear beam spot type

Spot type

Linear beam spot type

50±5mm (specular reflective mode 46±5mm) (note 2)

85±20 mm (specular reflective mode 81.4±6mm) ( note 2)

0.05m

0.15m

Class 2

Class 3R

Class 2

Class 3R

Ø70m

70x1000m

Ø70m

70x1000m

Ø100m

100x1200m

Ø100m

100x1200m

±0.03% F.S.

±0.03 % F.S. (specular reflective mode ±0.1 % F.S.)

90x26x74mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors

Measuring range: Model no. Type Measuring range Resolution Laser class Beam size Linearity Dimensions

110±15mm

HL-C211F

HL-C211FE

HL-C211F5

HL-C211F5E

HL-C211F-MK

HL-C211FE-MK

HL-C211F5-MK

HL-C211F5E-MK

Spot type

Linear beam spot type

110±15mm (specular reflective mode 106±14.7mm) (note 2)

0.1m

0.25m

0.1m

0.25m

0.1m

0.25m

0.1m

0.25m

Class 2

Class 3R

Class 2

Class 3R

Ø80m

Ø80x1700m

±0.03% F.S.

90x26x74mm

Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

Measuring range: Model no. Type Measuring range Resolution Laser class Beam size Linearity Dimensions

HL-C235CE-W Spot type
Ø400m

350±200mm HL-C235CE-WMK
Linear beam spot type 350±200 mm
2m Class 3R
400x6500m ±0.04% F.S. (-200 to 0mm), ±0.08% F.S. (0 to +200mm)
90x26x74mm

Notes: 1.) Models with a minimum resolution of 0.25m are subject to the Japanese export controls, defined in the "Foreign Exchange and Foreign Trade Act". This is not true for the model nos. in
brackets if the laser heads are ordered in combination with a controller (i.e. HL-C2CE) 2.) If the light reflection in "specular reflective mode" is too high, please use the optional filter (HL-C2F01)

HL-C2

 Common technical data

Emitting element Degree of protection Ambient temperature Material Connection method

Red laser diode, 658nm IP67 (IEC) 0 to +45°C
Enclosure: Die-cast aluminum / optical window: glass 0.5m cable with attached connector (extension cables, see page 129 (HL-G1CCJp)

 Controllers
Type
Model no. Supply voltage Analog output Output Inputs USB interface Serial input/output Current consumption Ambient temperature Material Connection method Dimensions (HxWxD)

RS232C interface

Ethernet interface

NPN

PNP

NPN

PNP

NPN

PNP

NPN

PNP

High resolution

Low resolution

High resolution

Low resolution

HL-C2C

HL-C2C-P

HL-C2CE

HL-C2CE-P

HL-C21C

HL-C21C-P

HL-C21CE

HL-C21CE-P

24V DC (±10%)

±5V/F.S., 4-20mA F.S.

NPN or PNP open collector transistor, max 100mA

Timing input, zero set, remote interlock, reset

USB 2.0

RS232C (9.6-115.2kbps)

With 1 sensor head: 350mA With 2 sensor heads: 500mA

0 to +50°C

Polycarbonate

Connector (sensors), terminal block

130x59x105.5mm

114 MEASUREMENT SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

HG-T
Laser thru-beam sensor

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 High precision
The laser thru-beam sensor of the HG-T series works with a beltshaped laser beam with a width of 10mm for measuring an area, e.g. for checking the contours of an edge.
The sensor achieves a repeatability of > 1µm and has a linearity of less than ± 12µm over the whole measurement range.

The thru-beam sensor has a sensing range of 500mm, which
HG-T
means that a larger variety of applications can be realized than with sensors with a shorter sensing range.

 Flexible mounting
The HG-T series comes with two different sensor heads, which differ in their dimensions. The slim type receiver is 10mm less wide than the standard type and fits well into machines with very limited space.

 Optical features
Thanks to functions like filters, edge detection, light intensity checks and averaging of measurement values (up to 1024), the measurements are very reliable. These functions help you to detect at an early stage when the measuring process does not run smoothly anymore and the system needs to be modified.

Accumulation of foreign matters

Increase the filter value!

Value resulting from foreign matters

Sensor heads
Standard type: Emitter: 8x30x60mm (WxDxH) Receiver: 8x30x60mm (WxDxH)
Slim type: Emitter: 8x30x60mm (WxDxH) Receiver: 8x20x60mm (WxDxH)

 Easy installation of multiple sensors
The master-slave system makes it easy to connect up to 15 sensors in series. Another feature increasing ease-of-use is the possibility to copy settings from the master to the slave units. A LED indicates when copying is in progress.

Receiver

Circle meter Green (OK) / No unlit indicator segment

Both beam axis adjustment indicators are ON.

Emitter

Static display

115

Typical applications
Highly precise measuring and checking of web edges

Measuring the flatness of glass sheets for transport
Glass substrate positioning

Measuring of diameters
Shaft diameter measurement

Technical specifications
 Sensor heads
Type Model no. Measurement range (width of laser belt) Measurement range Repeatability Protection Ambient temperatur Material Connection method
Dimensions (HxWxD)

Standard type

Slim type

HG-T1010

HG-T1110

10mm

0 to 500mm

max. 1m

IP67

-10 to +45°C

Housing: Die-cast aluminum, light emitting and receiving surfaces: Glass

cable with connector 0.2m (connection cable not included)

Emitter: 8x30x60mm Receiver: 8x30x60mm

Emitter: 8x30x60mm Receiver: 8x20x60mm

 Controllers

Type Model no.
Supply voltage Current consumption (note ) Sampling cycle

HG-TC101

Master unit

HG-TC101-P

HG-TC111 24V DC

Slave units HG-TC111-P

Max. 100mA (when sensor head is connected)

1ms (standard sampling) / 0.5ms (high-speed sampling)

Control output

NPN or PNP open collector transistor, max. 50 mA

Analog output (note 3)

4 to 20mA, 0 to 5V (Switchable)

Protection

IP40

Ambient temperature

-10 to +50°C

Dimension (HxWxD)

43.1x21.1x86

Material

Case: polycarbonate, cover: polycarbonate, keys: polyacetal

Connection method

Connector

Notes: Current consumption does not include analog current output

 Sensor head connection cable The sensor head connection cable has to be ordered separately.

Model No. Length

CN-HT-C2 2m

CN-HT-C5 5m

HG-TC113

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
HG-T

116 MEASUREMENT SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement
Sensors  Ultra high-speed response time of 25µs

Ionizers/

Electrostatic Sensors



Extremely low temperature deviations (0,07% F.S.°C)

Accessories GP-X

 Predefined material characteristics
The sensor exhibits ±0.3% F.S. linearity deviation when used on iron and stainless steel. Furthermore, characteristics for other materials are already programmed in the controller, making selection easy. Of course, the settings can also be customized.

 Serial interface
The controller can be connected with a personal computer via an RS-232 interface. GP-XAiME, the software included, simplifies data visualization and analysis. Moreover, several systems can be combined and then easily configured at the same time.

GP-X
Eddy current analog sensor for high-speed sampling
 The 5-digit, dual, 2-color digital display offers great visibility
If the measurement results fall within the setting range (GO), they will appear on the lower digital display in green. If they are out of setting range (HI, LO), they will be displayed in the upper digital display in orange. The display position and color change permit accurate visibility even for momentary changes.
Out of setting range (upper threshold) (Orange) Sensing values within setting range (Green) Out of setting range (lower threshold) (Orange)

Typical applications

Stroke end sensing

Eccentricity sensing

Height sensing

117

Technical specifications

Type Model no.

NPN output PNP output

GP-XC3SE (note 2)
GP-XC3SEP

Cylindrical heads GP-XC5SE GP-XC5SEP

GP-XC8S GP-XC8SP

GP-XC10M GP-XC10MP

Heads with thread GP-XC12ML GP-XC12MLP

GP-XC22KL GP-XC22KLP

Sensing range

0 to 0.8mm

0 to 1mm

0 to 2mm

0 to 2mm

0 to 5mm

0 to 10mm

Standard sensing object

Stainless steel (SUS304) / Iron sheet, cold rolled carbon steel (SPCC) 60x60x1mm

Power supply

24VDC ±10%

Analog voltage output

­5V to +5V (note 1)

Sampling rate Resolution Output

40kHz (25µs)
GP-XC3SE / GP-XC5SE: 0.04% F.S. (64 times average processing) GP-XC8S / GP-XC10M / GP-XC12ML / GP-XC22KL: 0.02% F.S. (64 times average processing)
3x NPN or PNP open-collector transistor, max. 100mA

Protection

Sensor head: IP67 (IEC)

Ambient temperature

Sensor head: ­10 to +55°C, Controller: 0 to +50°C

Material

Sensor head: stainless steel (SUS303), GP-XC12MLp, GP-XC22KLp: brass (nickel plated), Switch part: PC

Connection method

Dimensions

Sensor head (ØxD)
Controller (HxWxD)

3.8x17mm

Accessories

Notes: 1.) Factory setting: 0 to +5V 2.) Model no. for one set (sensor head and controller)

5.4x17mm

Terminal block

8x17mm

M10x17mm

48x48x83mm

Controller mounting frame, 1 pc.

M12x21mm

M12x35mm

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
GP-X

118 IONIZERS/ELECTROSTATIC SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors

 Small dimensions
Simple and space-saving installation on production lines and manual workstations.

Accessories
 Adjustable

A continuously variable adjuster ensures the production of the required air volume.
ER-Q
 Unit for demanding industrial environments

The LED displays the required maintenance steps or failures; this also can be queried via the outputs of a PLC. Parts for maintenance are easy to get at and replace.

ER-Q
Miniature ionizer with fan

Technical specifications
Type Model no. Charge removal time (±1000  ±100V) Discharge output voltage Ion balance Discharge method Power supply Power consumption Fan rotation speed Outputs Status indicator / Monitoring function Ambient temperature Ambient humidity Material Dimensions (HxWxD) Accessories

Standard type ER-Q
Approx. 1.5s ± 2kV
Max. ± 10V High frequency AC method
24VDC ±10% Max. 200mA Continuously variable adjustable (potentiometer) ERROR and CHECK NPN open-collector transistor, max. 50mA Ready/Discharging (DSC/green), Discharge error (red), Fan error (blinking red) 0 to +50°C 35 to 65%RH Enclosure: PBT, Discharge electrode needles: tungsten 60x33x65mm I/O connector set manufactured by MOLEX, Inc.: Housing 5557-08P, terminal 5556T

119

ER-F

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors

Laser Sensors

Features
 Two types
Low volume fan type. This type generates only the half of the air volume as the standard type, which is required for small components and thin film. Four different speeds can be selected for the fan.

Fan speed (m/s) Fan speed (m/s)

Standard fan type ER-F12
6.0 5.0 4.0 3.0 2.0 0.0 4 3 2 1
Fan levels

Low-volume fan type ER-F12S
6.0 5.0 4.0 3.0 2.0 0.0 4 3 2 1
Fan levels

Safety Sensors

 Easy maintenance
Because the discharge electrode needle unit is attached to the louver, exchange or maintenance of the electrode needles is made easy without touching the main unit. A safe design: once the louver is removed, the high-voltage circuit is broken and the fan halts. Simply replace the louver to change configuration between long distance and wide area ionization. The two louvers come with the ionizer main body.

Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
ER-F

Straight louver removes charges at great distances

Angled louver removes charges over wide area

Neutralizes static charges quickly from Neutralizes static charges; wide area

a great distance

ionizer

120 IONIZERS/ELECTROSTATIC SENSORS

IO-Link Technical specifications
Sensors

Photoelectric Sensors

Type

Fiber-optic Sensors

Model no.

Standard Fibers

Discharge time (±1000  ±100V)

Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

Discharge output voltage Ion balance Discharge method Power supply Power consumption Fan rotation speed Output Input terminal Status indicators / Monitoring functions Ambient temperature

Standard

Low-volume fan

ER-F12A

ER-F12SA

Approx. 1s

Approx. 1.5s

±2kV

Max. ±10V

High-frequency AC

24VDC ±10%

Max. 700mA

Max. 400mA

Adjustable at 4 levels

ERROR, NPN open-collector transistor, max. 50mA

Discharge stop = connected to 0V / Start= open

Power supply (Power / green), Discharging (DSC / green), Discharge error (DSC red), Fan error (FAN red)

0 to +50°C

Ambient humidity

ER-F

Material

35 to 65%RH Enclosure / Louver: ABS, Fitting of discharge electrode needles: PBT, Discharge electrode needles: tungsten, Mounting bracket: DC03

Dimensions (HxWxD)

166x161x60mm

Accessories Note: The discharge electrode needle set is mounted at the louver

Straight louver (note): 1 pc. Angle louver: 1 pc.; Caution label: 1 set; Rubber cushion: 1 pc.

121

ER-X
Area ionizer for fast applications

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors

Laser Sensors

Safety Sensors

Features
 Quick charge removal
Thanks to the pulse AC method, the ER-X series is well suited for high-speed applications as found in the packaging and semiconductor industries, where charge removal time is directly linked to productivity. In addition, discharge frequencies can be adjusted from between 1 and 100Hz, maximizing flexibility. Thanks to a built-in feedback system, the ionizer can even adjust the discharge frequency automatically during operation.
 Feedback system
Individual displays for discharge, error messages and electrode needle control are provided on the controller. Furthermore, you can activate settings for frequency, ion balance or limits directly via a potentiometer and DIP switches.

 Airless operation
The area ionizer of the ER-X series ionizers can be operated with or without air pressure. This technology opens up applications in fields such as the coating industry, as well as the production and packaging of microelectronic components that otherwise are blown around by whirling air.

Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

 Flexible system configuration

ER-X

The system consists of a sensor head and a controller. The sensor head is available in different sizes. You can connect parallel up to 2 heads to the controller. This enlarges the working area of the system up to 1.2m.

Typical applications

Neutralization of foils

Charge removal from ICs

Charge removal from miniaturized electronic components

122 IONIZERS/ELECTROSTATIC SENSORS

IO-Link Technical specifications
Sensors

Photoelectric Sensors



Sensor heads

Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors

Model no. Effective charge removal width Charge removal time (±1000  ±100V) Discharge output voltage Ion balance Discharge method Maximum air pressure Ambient temperature Ambient humidity Material

Spot ER-X001 Spot type Max. 0.5s

Accessories
 Controller

Model no. ER-X
Power supply

Power consumption

Outputs
Status display / Monitor functions of discharge unit
Ambient temperature

Ambient humidity

Material Dimensions (HxWxD) Accessories

Area

ER-X008

ER-X016

ER-X032

ER-X048

80mm

160mm

320mm

480mm

Approx. 1s

±7kV

Max. ±30V

Pulse AC method

5bar (0.5MPa)

0 to +50°C

35 to 65%RH

Enclosure: PPS, Stainless steel; Mounting bracket, Stainless steel; Electrode needle: tungsten

ER-XC02 24V DC ±10% 1 head: max. 450mA; 2 heads: max. 800mA Alarm, Error; PhotoMOS, max. 50mA Discharge (DSC)
0 to +50°C 35 to 65%RH
ABS 90x53x64mm MOLEX-plug (Housing 5557-10R, Terminal 5556TL) 1 pc., Ground wire 1pc.

ER-X064 640mm

 Sensor head connector cables
Model no.

ER-XCCJ2H

Image

Length

2m

Note: Cable is not included in delivery. Please order separately

ER-XCCJ5H 5m

ER-XCCJ10H 10m

123

ER-VW
Nozzle angle adjustment

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors

Safety Sensors

Features

 Nozzle angle adjustment
The angles of the two nozzles can be adjusted within a range of approximately 190° by screwing down the ends of the nozzles.

Installation examples
Vertical installation example

Horizontal installation example
 Compact and ultrathin design
The thickness of the unit is 18.9mm. Since the nozzle angles can be adjusted, they can be installed in tight spaces, such as when other equipment is present.

Pressure & Flow Sensors

Inductive Proximity Sensors

 Air supply monitoring function

This function causes discharging to stop automatically if the sup-

ply of air drops below a certain pressure. Notification of this is

given when the AIR indicator Air supply

Air supply

lights up and the discharge

output (DSC) turns off. This

prevents objects which are

not charged from being over-

looked when the air supply

has been stopped.

 Easy connection

Discharge

Discharge halt

possible

Measurement Sensors Ionizers/ Electrostatic Sensors Accessories
ER-VW

The joint kit (optional) can be used to connect up to a maximum of 5 ER-VW units. The air supply part is connected via quick connection joints, and the power supply and input//output signals can also be connected easily using connection cables with connectors at both ends.

Multiple ER-VW units can be connected to provide charge removal layouts that suit the target equipment.

Connection application example

End connector

Includes angle adjustment scale

 Minimum air consumption 15/min.
The ER-VW series can utilize air flow levels starting from a minimum of 15 l/min. Because the amount of air consumed is so low, the loads placed on air supply equipment can be reduced.

l

Comparison of air consumption Minimum 100l/min. (ANR) Maximum 300l/min. (ANR)
Previous spot type

ER-VW
0

l

Minimum 15l/min. (ANR) Maximum 60l/min. (ANR)

100

200

300

Air consumption

l/min. (ANR)

21

21 1
2

Joint kit
1 Cable with connector on both ends
Used to connect power supply, input / output and ground.
2 Air joint Used to supply air.

1 2

Cable with connector Air supply

124 IONIZERS / ELECTROSTATIC SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors
Safety Sensors

 Functions to support accurate charge removal
In addition to the air supply monitoring function, the ER-VW is equipped with the following functions to ensure accurate charge removal.

Power supply POWER
Discharge needle condition CHECK
Air supply monitoring AIR

Discharge DSC
Abnormal discharge ERROR

Pressure & Flow Sensors

Inductive

Proximity Sensors

Typical applications

Measurement Sensors
Ionizers/ Electrostatic
Sensors

Charge removal of ICs

Accessories

Removing charge during pickup from dicing type

Parallel discharging on two assembly lines

Removing charges from LCD transport brackets

ER-VW

Technical specifications
Type Model no. Charge removal time (±1000  ±100V) Discharge output voltage Ion balance Discharge method Power supply Power consumption Air pressure Inputs Outputs Status indicators / Monitoring functions Ambient temperature Ambient humidity Material Dimensions (HxWxD) Accessories

Spot ER-VW Max. 1s ± 2kV Max. ±10V High frequency AC method 24VDC ±10% Max. 120mA 0.5 to 5bar (0.05 to 0.50MPa) Reset and discharge stop = connected to 0V / Start= open Discharging (DSC), ERROR and CHECK; NPN open collector transistor; max. 50mA Supply voltage (Power / green), Discharging (DSC / green), Checking electrode needles (Check / orange), Monitoring air pressur (Air / orange), Failure (Error / red) 0 to +55°C 35 to 65%RH Enclosure: ABS (nickel plated), nozzles / nozzle mount, Screws: stainless steel, Discharge electrode needles: tungsten 19x133x65mm Connector cable with 8 pins, 0.5m, Terminating plug with 9 pins, Ground wire

125

ER-V
Ultra compact high-performance ionizer

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors

Safety Sensors

Features
 Produces excellent ion balance
The adoption of high-frequency AC method allows extremely stable ion balance to be achieved. Because the ion balance is not affected by the pressure of air supplied or by the setup distance, no troublesome adjustments are required after setup.
 High performance but no controller needed
A full range of functions have been provided with full consideration given to ease of use in the workplace. No separate controller is needed.

 Ultra compact design accurately removes charges of objects even from narrow spaces
The main unit is merely 28x27x111.6mm so it can easily be combined with other devices and also be installed as an add-on. Furthermore, the high-voltage power supply is built-in so no extra space is required except for the ionizer itself.

Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
ER-V

 Nozzle variations can be selected to suit the application

Shower nozzle

Straight bar nozzle

Shape-preserving tube

Conductive tube

28mm

27mm (With sho110w19em1rm.n6om(Mzzmalien aunttiat cohnleyd) )

It can be installed in places where the conventional bar type cannot so it can be placed closer to the object for more accurate charge removal.

Typical applications

CChharnggeerreemmoovvaallaanndd dust rreemmoovvaalloofflelennsseess

PcPcirrirecrecvuvueietintnbtbtododaiasirscrdcdhhLaLaErErgDgDesesddaammaaggee iinn

Charge removal glass surfaces

126 IONIZERS / ELECTROSTATIC SENSORS

IO-Link Technical specifications
Sensors

Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Type Model no. Charge removal time (±1000  ±100V) Discharge output voltage Ion balance Discharge method

Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

Power supply Power consumption Maximum air pressure Inputs Outputs Status indicators / Monitoring functions Ambient temperature Ambient humidity Material

Dimensions (HxWxD)

ER-V

Accessories

Spot ER-VS02 Max. 1s
±2kV Max. ±10V High frequency AC method 24VDC ±10% Max. 70mA 0.5 to 7bar (0,05 to 0.7MPa) Reset and discharge stop = connected to 0V / Start= open Error (ERROR) and check (CHECK) NPN open-collector transistor, max. 50mA Supply voltage (Power / green), Discharging (DSC / green), Checking electrode needles (Check / orange), Error (Error / red) 0 to +55°C 35 to 65%RH Enclosure: PPS, Cover: stainless steel, Discharge electrode needles: tungsten 28x27x111.6mm I/O connector set manufactured by MOLEX, Inc.: Housing 5557-08P, terminal 5556TL

 Nozzles
Type Model no.

Shower nozzle
ER-VAS

Straight bar nozzle ER-VAB020 ER-VAB032 ER-VAB065

Tube nozzle adapter
ER-VAJK

Shape-preserving tube ER-VAK10 ER-VAK30

ER-VAK50

Conductive tube Tube nozzle
adapter
ER-VAJT-64 ER-AT50

Image

Length Description

Shower nozzle

Effective charge removal length 200mm

Effective charge removal length 320mm

Effective charge removal length 650mm

Straight bar nozzle containing a series of holes

Note: Nozzles are not supplied with the ionizer main unit. Please order them separately.

Tube nozzle adapter for main system and shapepreserving
tube

Tube length Tube length Tube length

112mm

312mm

512mm

Bends easily and holds its bent shape so the tube does not need to be secured. (Minimum bending radius: 40mm)

Tube nozzle adapter for main system and conduc-
tive tube

Tube length 500mm
Flexible, free-cut (Minimum bending radius: 15mm)

 Cable with connector

Model no.

ER-VCCJ2

ER-VCCJ5

ER-VCCJ9

Image

Length

2m

5m

Net weight

approx. 52g

approx. 120g

Description

0.15mm2 8-core cab tire cable with connector Cable outer diameter: Ø4.2mm

Note: The cable with connector is not supplied with the ionizer main unit. Please order it separately.

9m approx. 240g

127

EC-G
Pulse air-gun ionizer

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors

Safety Sensors

Features
 Direct ionized air emission from air gun
With the new pulse air-gun ionizer operators can comfortably neutralize static electricity while manually cleaning.
 Pulsed ionized air
Instant pulse air emission with high air pressure removes dust all at once. Its lightweight construction, ergonomic design and 2m cable make the air gun the perfect ionizer for manual jobs.
 White LED illumination
A convenient white LED on the front of the gun illuminates target objects.

Technical specifications

Type

Air gun type

Model no.
Charge removal time (±1000  ±100V)
Discharge output voltage

EC-G02 Average 0.5s
±1kV

Ion balance

Max. ±10V

Discharge method

High frequency AC method

Power supply

Input voltage: 100 to 240VAC, output voltage: 24VDC ±10%

Power consumption

Max. 30VA

Maximum air pressure

0.5 to 5bar (0.05 to 0.50MPa)

Input terminal Modes LED illumination mode

Charge removal start = connected to 0V Pulse 1 (long) and Pulse 2 (short) / CONT (continuous)
selectable by switch
White LED

Status indicator / Monitoring function
Ambient temperature

Valve illumination (orange) 0 to +50°C

Ambient humidity

35 to 65% RH (no condensation allowed)

Material

Enclosure: ABS, Nozzle: Stainless steel, Nozzle guard: NBR, Discharge electrode needle: tungsten

Weight

approx. 270g

Accessories

AC adapter, 1 pc.; Exclusive intermediate cable, 2m; Straight joints to couple air tubes ø 8-8mm (note) and ø 8-6mm type, Connector connection terminal from MOLEX

Note: Straight joint to couple air tubes, ø 8mm, is attached at shipment

Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
EC-G

Typical applications
Remove charge and dust on PCB

Remove charge and dust on flat screens

Remove dust before painting

128 IONIZERS / ELECTROSTATIC SENSORS

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors
Laser Sensors

EF-S1
Constant monitoring of static charges on production lines

Safety Sensors

Pressure & Flow Sensors

Inductive
Features Proximity Sensors

Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

 Maintains and regulates product quality by preventing damage from static electric
Static electricity that can build up in various places along a process line can be monitored constantly so that abnormalities can be prevented before they occur, ensuring quality.

 Reduces time for ionizer inspections
EF-S1 The de-ionizing effectiveness of ionizers can be understood in real-time so that things such as ionizer damage and the replacement period for worn components can be checked objectively, reducing the time required for inspection and testing.

Technical specifications

 Sensor head

Type

Spot type

Model no. Measuring range

EF-S1HS
8.0 to 20.5mm (±1kV) 21.0 to 100mm (±2kV)

 Controller
Type Model no.

Spot type EF-S1C

Power supply Display range (Measurement range) Judgment output
Analog voltage output

24VDC ±10%
-1000 to 1000 (±1kV) -1999 to 1999 (±2kV)
NPN open-collector transistor, max. 100mA
Output voltage 1 to 5V Load impedance approx. 100

Typical applications
Measuring surface potential when removing BG sheets

Measuring static electric charge in lead frames

Measuring frictional electrification of LCD modules

 Cables
Picture

ACCESSORIES 129

Description 4-pin M8 connector cable, 2m
4-pin M8 connector cable (elbow type 90°), 2m
4-pin M8 connector cable, 5m
4-pin M8 connector cable (elbow type 90°), 5m
4-pin M12 connector cable, 2m
4-pin M12 connector cable (elbow type 90°), 2m
4-pin M12 connector cable, 5m
4-pin M12 connector cable (elbow type 90°), 5m
4-wire cable with connector, 2m 4-wire cable with connector, 5m 3-wire cable with connector, 1m 3-wire cable with connector, 3m
3-wire main cable, 2m 3-wire main cable, 5m 1-wire sub cable, 2m 1-wire sub cable, 5m 4-wire main cable, 2m 4-wire main cable, 5m 2-wire sub cable, 2m 2-wire sub cable, 5m 14-wire connecting cable, 2m 14-wire connecting cable, 5m
14-wire cable, 10m 14-wire cable, 20m 14-wire cable, 2m 14-wire cable, 5m 14-wire cable, 10m 14-wire cable, 20m 14-wire cable, 30m

Model no. UZZ80820D UZZ80821D UZZ80850D UZZ80851D UZZ81220D UZZ81221D UZZ81250D UZZ81251D

Applicable sensors CX-4pZ,FX101pZ, FX102pZ, DP11pEPJ CX-4pZ, FX101pZ, FX102pZ, DP11pEPJ CX-4pZ,FX101pZ, FX102pZ, DP11pEPJ CX-4pZ,FX101PZ, FX102pZ, DP11pEPJ LX-101pZ, CX-4pZ, EQ-30, CY-1pZ, GX-Mp-Z LX-101pZ, CX-4pZ, EQ-30, CY-1pZ, GX-Mp-Z LX-101pZ, CX-4pZ, EQ-30, CY-1pZ, GX-Mp-Z LX-101pZ, CX-4pZ, EQ-30, CY-1pZ, GX-Mp-Z

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors
Inductive Proximity Sensors
Measurement Sensors
Ionizers/ Electrostatic Sensors
Accessories

CN14AC2 CN14AC5 CN13C1 CN13C3 CN73C2 CN73C5 CN71C2 CN71C5 CN74C2 CN74C5 CN72C2 CN72C5 HL-G1CCJ2 HL-G1CCJ5 HLG1CCJ10 HLG1CCJ20 HL-C2CCJ2 HL-C2CCJ5 HL-C2CCJ10 HL-C2CCJ20 HL-C2CCJ30

PM-p65, DP-100, DP-0 PM-p65, DP-100, DP-0
PM2 PM2 FX-301p, FX311, FX-5p1p, FX-CH2p, SC-GU-1-485 FX-301p, FX311, FX-5p1p, FX-CH2p, SC-GU-1-485 FX-301p, FX-311, FX-501p FX-301p, FX-311, FX-501p FX-305p, FX-502p, LS-401p, LS-501p FX-305p, FX-502p, LS-401p, LS-501p FX-305p, FX-502p, LS-401p, LS-501p FX-305p, FX-502p, LS-401p, LS-501p HL-G1p-S-J HL-G1p-S-J HL-G1p-S-J HL-G1p-S-J HL-C2p HL-C2p HL-C2p HL-C2p HL-C2p

Cables

130 ACCESSORIES

IO-Link  Reflectors
Sensors

Photoelectric Sensors

Picture

Fiber-optic Sensors

Standard Fibers
Fiber Sensors Communication
Units
Mark Sensors

Laser Sensors

Safety Sensors
Pressure & Flow Sensors
Inductive Proximity
Sensors
Measurement Sensors
Ionizers/ Electrostatic
Sensors
Accessories

Reflectors

Description Reflection foil: 8x30mm, thickness 0.7mm

Model no. RF11

Reflection foil: 25x30mm, thickness 0.7mm

RF12

Reflection foil: 30x30mm, thickness 0.5mm

RF13

Reflective area: 9.6x17.5mm

RF200

Reflective area: 12.8x33.3mm

RF210

Reflective area: 42.3x35.3mm

RF220

Reflective area: 59.3x50.3mm

RF230

Reflective area: 7x8mm

RF310

Reflection foil: 27.8 x25.2mm

RF33

Reflective area: 23x24mm

RF330

Reflective area: 24x21mm

RF-420

Reflective area: 50x47mm

RF-410

Adhesive reflection tape: 22mm x 5m, thickness 0.4mm

RF-40RL5

Applicable reflectors CX-400, EX-20, NX5 CX-400, EX-20, NX5
CX-400 EX-20 CX-400, EX-L200, NX5 CX-400, NX5 CX-400, LS-H92p, NX5
LS LS EX-L200, LS-H91p, LS-H901 CY-100 CY-100 CY-100

 Mounting brackets
Picture

Description L-shaped mounting bracket

Model no. MS-EXL2-1

Mounting plate

MSLX1

Mounting bracket

MSCX1

Mounting bracket

MSCX21

Mounting bracket

MSNX51

Mounting bracket

MS-EXZ-2

Mounting bracket

MS-EXZ-2

Mounting bracket

MSEX101

Mounting bracket

MSEX201

Mounting bracket

MSEX202

Mounting set, 4 mounting brackets M4(l=15mm) 4pcs., M4 (l=18mm) 8pcs.

MSNA11

Mounting bracket

MSEQ501

Mounting bracket

MSEQ31

Mounting bracket

MSDIN4

Mounting bracket

MSDIN2

Mounting bracket

MS-FM2-1

Mounting bracket

MSDP11

Mounting bracket

MS-DP1-6

Mountig bracket, stainless steel

MS-CY1-1

Mounting bracket for beam axis alignment, plastic

MS-CY1-2

131

Applicable reflectors EX-L200, LS-H102
LX-100 CX-400, LS-400
CX-400 NX5
EX-Z Top sensing EX-Z Side sensing
EX-10 EX-20 Top sensing EX-20 Side sensing
NA1-11 EQ-500 EQ-30 FX-100 FX-300, FX-500 FM-200 DP-100, DP-0 DPC-100, DPC-L100 CY-100 CY-100

IO-Link Sensors
Photoelectric Sensors
Fiber-optic Sensors
Standard Fibers
Fiber Sensors Communication Units
Mark Sensors
Laser Sensors
Safety Sensors
Pressure & Flow Sensors Inductive Proximity Sensors Measurement Sensors Ionizers/ Electrostatic Sensors
Accessories
Mounting brackets

Global Network
Global Network

North America

Europe

Asia Pacific

China

Japan

Panasonic Electric Works

Please contact our Global Sales Companies in:
Europe

 Headquarters  Austria

Panasonic Electric Works Europe AG Panasonic Industry Austria GmbH

 Benelux  Czech Republic
 France  Germany  Hungary

Panasonic Industrial Devices Materials Europe GmbH Panasonic Electric Works
Sales Western Europe B.V. Panasonic Electric Works Europe AG,
organizacní slozka
Panasonic Electric Works Sales Western Europe B.V.
Panasonic Electric Works Europe AG Panasonic Electric Works Europe AG

 Ireland  Italy

Panasonic Electric Works UK Ltd. Panasonic Industry Italia srl

 Nordic Countries Panasonic Electric Works Europe AG

Panasonic Fire & Security Europe AB

 Poland

Panasonic Industry Poland sp. z o.o.

 Spain

Panasonic Industry Iberia S.A.

 Switzerland

Panasonic Industry Switzerland AG

 United Kingdom Panasonic Electric Works UK Ltd.

Caroline-Herschel-Strasse 100, 85521 Ottobrunn, Tel. +49 89 45354-1000, Fax +49 89 45354-1550, www.panasonic-electric-works.com Josef Madersperger Str. 2, 2362 Biedermannsdorf, Tel. +43 (0) 2236-26846, Fax +43 (0) 2236-46133 www.panasonic-electric-works.at Ennshafenstraße 30, 4470 Enns, Tel. +43 (0) 7223 883, Fax +43 (0) 7223 88333, www.panasonic-electronic-materials.com
De Rijn 4, 5684 PJ Best, Netherlands, Tel. +31 (0) 499 372727, www.panasonic-electric-works.nl
Administrative centre PLATINIUM, Veveí 3163/111, 616 00 Brno, Tel. +420 541 217 001, Fax +420 541 217 101, www.panasonic-electric-works.cz Succursale française, 10, rue des petits ruisseaux, 91370 Verrières Le Buisson, Tél. +33 (0) 1 6013 5757, Fax +33 (0) 1 6013 5758, www.panasonic-electric-works.fr Caroline-Herschel-Strasse 100, 85521 Ottobrunn, Tel. +49 89 45354-1000, Fax +49 89 45354-2111, www.panasonic-electric-works.de Magyarországi Fióktelepe, 1117 Budapest, Alíz utca 4, Tel. +43 (0) 2236 26846 -25, Fax +43 (0) 2236 46133 www.panasonic-electric-works.hu Irish Branch Office, Dublin, Tel. +353 (0) 14600969, Fax +353 (0) 14601131, www.panasonic-electric-works.co.uk Via del Commercio 3-5 (Z.I. Ferlina), 37012 Bussolengo (VR), Tel. +39 0456752711, Fax +39 0456700444, www.panasonic-electric-works.it Filial Nordic, Knarrarnäsgatan 15, 164 40 Kista, Sweden, Tel. +46 859476680, Fax +46 859476690, www.panasonic-electric-works.se Jungmansgatan 12, 21119 Malmö, Tel. +46 40 697 7000, Fax +46 40 697 7099, www.panasonic-fire-security.com Ul. Dowborczyków 25, 90-019 Lód, Polska, Tel. +48 42 2309633, www.panasonic-electric-works.pl Barajas Park, San Severo 20, 28042 Madrid, Tel. +34 913293875, Fax +34 913292976, www.panasonic-electric-works.es Grundstrasse 8, 6343 Rotkreuz, Tel. +41 (0) 41 7997050, Fax +41 (0) 41 7997055, www.panasonic-electric-works.ch Sunrise Parkway, Linford Wood, Milton Keynes, MK14 6 LF, Tel. +44 (0) 1908 231555, Fax +44 (0) 1908 231599, www.panasonic-electric-works.co.uk

North & South America

 USA

Panasonic Industrial Devices Sales Company Two Riverfront Plaza, 7th Floor, Newark, NJ 07102-5490, Tel. 1-8003-442-112, www.pewa.panasonic.com of America

Asia Pacific / China / Japan

 China
 Hong Kong
 Japan  Singapore

Panasonic Electric Works Sales (China) Co. Ltd.
Panasonic Industrial Devices Sales (HK) Co., Ltd. Panasonic Corporation Panasonic Industrial Devices Automation Controls Sales Asia Pacific

Tower C 3rd Floor, Office Park, NO.5 Jinghua South Street, Chaoyang District, Beijing 100020, Tel. +86-10-5925-5988, Fax +86-10-5925-5980 Suite 301, 3/F, Chinachem Golden Plaza, 77 Mody Road, TST East, Kowloon, Hong Kong, Tel. +852-2529-3956, Fax +852-2528-6991
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8501, Japan, Tel. +81-6-6908-1121, www.panasonic.net No.3 Bedok South Road, Singapore 469269, Tel. +65-6299-9181, Fax +65-6390-3953



Copyright © 2021 · Printed in Germany



3174 euen 07/21


Adobe PDF Library 15.0 Adobe InDesign 16.2 (Windows)