Junos OS Junos OS Software Installation and Upgrade Guide

256 OS Software Installation and Upgrade Guide

256 OS Software Installation and Upgrade Guide ... 2

Junos OS - Juniper Networks

Hit [Enter] to boot immediately, or space bar for command prompt. Press the Spacebar to enter the manual loader. The loader> prompt appears.

Junos OS Software Installation and Upgrade Guide

Understanding Manual BIOS Upgrade Using the Junos CLI. ... If you want to use the examples in this manual, you can use the load merge or the load merge relative command.

PDF software-installation-and-upgrade
Junos® OS
Junos® OS Software Installation and Upgrade Guide
Published
2021-03-24

ii
Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, California 94089 USA 408-745-2000 www.juniper.net
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. in the United States and other countries. All other trademarks, service marks, registered marks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
Junos® OS Junos® OS Software Installation and Upgrade Guide Copyright © 2021 Juniper Networks, Inc. All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement ("EULA") posted at https://support.juniper.net/support/eula/. By downloading, installing or using such software, you agree to the terms and conditions of that EULA.

iii
Table of Contents

About This Guide | xxi

1

Junos OS Overview

Junos OS Overview | 2

Junos OS Overview | 2

2

System Back Up and Recovery

Backing Up an Installation Using Snapshots | 7

Understanding How to Back Up an Installation on Switches | 7

Creating a Snapshot and Using It to Boot a QFX Series Switch | 9
Creating a Snapshot on an External USB Flash Drive and Using It to Boot a QFX Series Switch | 10
Creating a Snapshot and Using It to Boot a QFX3500 and QFX3600 Series Switch | 11

Creating a Snapshot and Using It to Boot an EX Series Switch | 14 Creating a Snapshot on a USB Flash Drive and Using It to Boot the Switch | 14

Creating a Snapshot and Using It to Boot an SRX Series device | 15 Creating a Snapshot and Using It to Boot an SRX Series device | 15 Backing Up the Current Installation on SRX Series Devices | 18

Creating a Snapshot and Using It to Boot an ACX Series Router | 21 Understanding System Snapshot on an ACX Series Router | 21 Example: Taking a Snapshot of the Software and Configuration | 22

Recovery Using an Emergency Boot Device | 26 Creating an Emergency Boot Device for Routers | 27

Creating an Emergency Boot Device for QFX Series Switches | 28

Recovering the Installation Using an Emergency Boot Device | 30

Performing a Recovery Installation | 32

Rescue and Recovery of Configuration File | 33 Saving and Reverting a Rescue Configuration File | 34

iv

Saving a Rescue Configuration File | 34 Reverting to the Rescue Configuration | 38

Copy Backup Configurations and Restoring a Saved Configurations | 39 Copy Backup Configurations to the Router | 39 Restoring a Saved Configuration | 39

Reverting to the Default Factory Configuration by Using the request system zeroize Command | 42

Recovery of Junos OS | 42 Recovering from a Failed Software Installation | 43

Recovering Junos OS on a Device Running Junos OS with Upgraded FreeBSD | 45

How to Recover Junos OS with Upgraded FreeBSD | 49 Ways to Recover Junos OS with Upgraded FreeBSD Without the Use of the CLI | 49

How to Access the Junos Main Menu, Boot Menu, and Options Menu | 53 How to Access the Junos Main Menu | 53 How to Access the Boot Menu | 55 How to Access the Options Menu | 56

Autorecovery of Configuration, Licenses, and Disk Information on SRX Series Devices | 57

3

Installing, Upgrading, and Downgrading Software

Software Installation and Upgrade Overview | 63

Software Installation and Upgrade Overview | 63

Junos OS and Junos OS Evolved Installation Package Names | 69 Junos OS and Junos OS Evolved Installation Packages Prefixes | 70 Junos OS and Junos OS Evolved Release Numbers | 75 Junos OS and Junos OS Evolved Editions | 76

Boot Sequence on Devices with Routing Engines | 77

Preparing for Software Installation and Upgrade | 81 Upgrade or Reinstall Junos OS | 82 Checklist for Reinstalling Junos OS | 82 Log the Software Version Information | 84 Log the Hardware Version Information | 86 Log the Chassis Environment Information | 88

v
Log the System Boot-Message Information | 89 Log the Active Configuration | 92 Log the Interfaces on the Router | 93 Log the BGP, IS-IS, and OSPF Adjacency Information | 94 Log the System Storage Information | 96
Validating the Configuration Image Before Upgrading or Downgrading the Software | 97
Ensuring Sufficient Disk Space for Junos OS Upgrades on SRX Devices | 98 Verifying Available Disk Space on SRX Series Devices | 98 Cleaning Up the System File Storage Space | 99
Verifying Junos OS and Boot Loader Software Versions on an EX Series Switch | 101 Verifying the Number of Partitions and File System Mountings | 101 Verifying the Loader Software Version | 103 Verifying Which Root Partition Is Active | 104 Verifying the Junos OS Version in Each Root Partition | 105
Downloading Software | 107 Downloading Software Using a Browser | 107 Downloading Software Using the Command-Line Interface | 108 Downloading Software Using Download Manager (SRX Series Only) | 110
Reinstall Junos OS | 112
Reconfigure Junos OS | 113 Configure Host Names, Domain Names, and IP Addresses | 113 Protecting Network Security by Configuring the Root Password | 115 Check Network Connectivity | 117
Managing YANG Packages and Configurations During a Software Upgrade or Downgrade | 118 Backing up and Deleting the Configuration Data | 119
Restoring the YANG Packages and Configuration Data | 119
Installing Software on Routing Devices | 121 Installing the Software Package on a Router with a Single Routing Engine | 121
Installing the Software Package on a Device with Redundant Routing Engines | 123 Preparing the Device for the Installation | 123

vi
Installing Software on the Backup Routing Engine | 125 Installing Software on the Remaining Routing Engine | 127 Finalizing the Installation | 130
Installing Software on EX Series Switches | 132 Understanding Software Installation on EX Series Switches | 133
Installing Software on an EX Series Switch with a Virtual Chassis or Single Routing Engine (CLI Procedure) | 135
Installing Software on an EX Series Switch with Redundant Routing Engines (CLI Procedure) | 138 Preparing the Switch for the Software Installation | 139 Installing Software on the Backup Routing Engine | 141 Installing Software on the Default Primary Routing Engine | 142 Returning Routing Control to the Default Primary Routing Engine (Optional) | 144
Upgrading the Loader Software on the Line Cards in a Standalone EX8200 Switch or an EX8200 Virtual Chassis | 145
Booting an EX Series Switch Using a Software Package Stored on a USB Flash Drive | 149
Installing Software on QFX Series Devices | 151 Installing Software Packages on QFX Series Devices | 151 Installing the Software on QFX10002-60C Switches | 152 Installing a Standard Software Package on QFX5000 and EX4600 Switches | 153 Installing a Standard Software Package on QFX10002 Switches | 154 Upgrading Software from Junos OS Release 15.1X53-D3X to Junos OS Release 15.1X53D60, 15.1X53-D61.7, 15.1X53-D62, and 15.1X53-D63 on QFX10008 and QFX10016 Switches | 157 Installing a Software Package on QFX10008 and QFX10016 Switches | 161
Upgrading Software by Using Automatic Software Download for Switches | 165 Configuring DHCP Services for the Switch | 166 Enabling Automatic Software Download on a Switch | 166 Verifying That Automatic Software Download Is Working Correctly | 167
Upgrading Jloader Software on QFX Series Devices | 168 Jloader Software Version 1.1.4 Guidelines | 171 Upgrading Jloader Software on a QFX3500 Switch | 171 Upgrading Jloader Software on a QFabric System | 174

vii
Installing Junos OS Software with Junos Automation Enhancements | 183 How To Install Third-Party Software on Devices Running Junos OS Evolved | 189 Personality Upgrade Process | 191
Understanding the Personality Upgrade Process for a Device | 191 Supported Personality Upgrades | 193 Upgrading the Personality of a Device by Using a USB Flash Drive | 194 Upgrading the Personality of a Device by Using CLI | 195
How to Upgrade the Personality of a Device on Junos OS | 195 Upgrading the Personality of a Device by Using a PXE Boot Server | 198 Upgrading the Personality of SRX1500 Device by Using a PXE Boot Server | 202 Upgrading the Personality of SRX4100 Device by Using a PXE Boot Server | 206 Upgrading the Personality of SRX4600 Device by Using a PXE Boot Server | 210 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices | 214 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the PXE Boot
Server | 214 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the USB
Option | 219 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the CLI
Option | 220 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using Zero Touch
Provisioning (ZTP) | 222 Upgrade the NFX250 Software to NFX250 NextGen Software | 230
NFX250 NextGen Software Upgrade Overview | 230 Prerequisites | 230 Upgrade to NFX250 NextGen Software Architecture | 233 Installing Software on SRX Series Devices | 233 Understanding Junos OS Upgrades for SRX Series Devices | 234 Example: Installing Junos OS Upgrade Packages on SRX Series Devices | 236

viii
Requirements | 236 Overview | 237 Configuration | 237 Verification | 239
Example: Installing Junos OS on SRX Series Devices Using the Partition Option | 240 Requirements | 240 Overview | 240 Configuration | 241 Verification | 244
Reverting the Junos OS Software Image Back to the Previous Version | 245 Requirements | 245 Overview | 245 Configuration | 246 Verification | 247
Preparing the USB Flash Drive to Upgrade Junos OS on SRX Series Devices | 248
Installing Junos OS on SRX Series Devices Using a USB Flash Drive | 250
Upgrading the Boot Loader on SRX Series Devices | 251
Installing Junos OS on SRX Series Devices from the Boot Loader Using a TFTP Server | 252
Installing Junos OS on SRX Series Devices from the Boot Loader Using a USB Storage Device | 255
Restarting and Halting SRX Series Devices | 256 Rebooting SRX Series Devices | 257 Halting SRX Series Devices | 260 Bringing Chassis Components Online and Offline on SRX Series Devices | 262 Restarting the Chassis on SRX Series Devices | 263
Upgrading and Downgrading to Junos with Upgraded FreeBSD | 264 Upgrading Junos OS with Upgraded FreeBSD | 265 Determine Which Package or Packages to Install | 266 Install Junos OS with Upgraded FreeBSD Over Junos OS | 269 Install Junos OS with Upgraded FreeBSD Over Junos OS with Upgraded FreeBSD of a Different Release | 271
Downgrading from Junos OS with Upgraded FreeBSD | 272

ix
Downgrading from Junos OS with Upgraded FreeBSD to Legacy Junos OS | 273 Downgrading from Junos OS with Upgraded FreeBSD Release 17.4 or Later to Release 15.1
Through 17.3 | 274 Downgrading from Junos OS with Upgraded FreeBSD Release 17.3 or Earlier to Release
15.1 Through 17.2 | 275 Downgrading from Junos OS with Upgraded FreeBSD Release 18.1 or Later to Release 17.4
or Later | 276 Installing Software on ACX Series Routers | 277
Installing Junos OS Using a USB Storage Device on ACX Series Routers | 277 Installing Junos OS Upgrades from a Remote Server on ACX Series Routers | 278 Installing and Recovering Software Using the Open Network Install Environment (ONIE) | 279 Understanding the Open Network Install Environment | 280 Downloading Software Files with a Browser | 281 Connecting to the Console Port | 282 Backing Up the Current Configuration Files | 282 Uninstalling the Existing Version of Junos OS | 282 Installing a Junos OS Software Package That Resides on a Webserver or DHCP Server with
DHCP Options Configured | 283 Installing Junos OS Software Using Secure Copy Protocol (SCP) | 284 Installing Junos OS Software Using FTP or TFTP Without a Webserver | 285 Installing Junos OS Software Using DHCP Server with No DHCP Options Configured | 286 Installing Junos OS Software Using Webserver Without DHCP Configured | 287 Installing Junos OS Software Using USB Media | 289 Verifying Software Installation | 289 Troubleshooting Boot Problems | 290 Creating an Emergency Boot Device | 291 Performing a Recovery Installation | 292 Overview of Upgrading to 64-bit Junos OS | 294

x

Upgrading Redundant Routing Engines from 32-bit to 64-bit Junos OS | 295

Upgrading a Single Routing Engine from 32-bit to 64-bit Junos OS Using One Slot | 297

Upgrading a Single Routing Engine from 32-bit to 64-bit Junos OS Using Two Slots | 297

Veriexec Overview | 299

4

VM Host Support on Routing Engines

VM Host Overview | 308

What Are VM Hosts? | 308

Routing Engines with VM Host Support | 309

Salient Features of the Routing Engines with VM Host Support | 310

Boot Process for Routers with VM Host Support | 317

Installing, Upgrading, Backing Up, and Recovery of VM Host | 319

Copying VM Host Installation Package to the PXE Boot Server | 325

Creating an Emergency Boot Device for Routing Engines with VM Host Support | 328

Upgrading the SSD Firmware on Routing Engines with VM Host Support | 330

Upgrading the i40e NVM Firmware on Routing Engines with VM Host Support | 333

Disabling Autorecovery on Routing Engines with VM Host Support | 343

VM Host Operations and Management | 343

5

Installing and Upgrading the BIOS and Firmware

Upgrading BIOS and Firmware | 347

Understanding BIOS Upgrades on SRX Series Devices | 347

Disabling Auto BIOS Upgrade on SRX Series Devices | 349

Installing and Upgrading Firmware | 351 Before You Begin Installing or Upgrading the Firmware | 351

Installing Firmware on the 5-Port 100-Gigabit DWDM OTN PIC (PTX-5-100G-WDM) | 354

Upgrading Firmware on the 5-Port 100-Gigabit DWDM OTN PIC (PTX-5-100G-WDM) | 355

Installing Firmware on the 100-Gigabit DWDM OTN MIC (MIC3-100G-DWDM) | 357

xi

Upgrading Firmware on the 100-Gigabit DWDM OTN MIC (MIC3-100G-DWDM) | 358

Installing Firmware on ACX6360 Router | 360

Upgrading Firmware on the ACX6360 Router | 361

6

Configuring Root Partitions

Configuring Dual-Root Partitions | 365

Configuring Root Partitions on SRX Series Devices | 369 Dual-Root Partitioning Scheme on SRX Series Devices | 369

Reinstalling the Single-Root Partition on SRX Series Devices | 376

Configuring Root Partitions on ACX Series Routers | 377 Dual-Root Partitioning ACX Series Routers Overview | 378

Understanding How the Primary Junos OS Image with Dual-Root Partitioning Recovers on the ACX Series Router | 379

Junos OS Release 12.2 or Later Upgrades with Dual-Root Partitioning on ACX Series Routers | 381

Example: Installing Junos OS and Configuring a Dual-Root Partition on ACX Series Routers Using the CLI | 382 Requirements | 382 Overview | 382 Configuration | 383 Verification | 386

7

Storage Media and Routing Engines

Storage Media and Routing Engines | 389

Routing Engines and Storage Media | 389

Repartitioning Routing Engine System Storage to Increase the Swap Partition | 390

System Memory and Storage Media on Routers | 391

Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, PTX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers) | 394

System Memory and Storage Media for SRX Series Services Gateways | 398

Accessing USB Storage on PTX1000 Routers | 403

8

Zero Touch Provisioning

xii

Zero Touch Provisioning | 406 Zero Touch Provisioning Overview | 406

Zero Touch Provisioning Using DHCP Options | 414

Zero Touch Provisioning Using DHCPv6 Options | 422

Zero Touch Provisioning on SRX Series Devices | 429
Understanding Zero Touch Provisioning on SRX Series Devices | 429 Configuring Zero-Touch Provisioning on an SRX Series Device | 433 Understanding Factory-Default Configuration on SRX Series Device for Zero Touch
Provisioning | 437

Monitoring Zero Touch Provisioning | 438 Using the Console to Monitor Zero Touch Provisioning | 439 Using System Log Alerts to Monitor Zero Touch Provisioning | 439 Using Error Messages to Monitor Zero Touch Provisioning | 440 Using System Log Files to Monitor Zero Touch Provisioning in Junos OS Using DHCP Options | 441 Using System Log Files to Monitor Zero Touch Provisioning in Junos OS Using DHCPv6 Options | 442 Using the Console to Monitor Zero Touch Provisioning in Junos OS Evolved | 443 Using the show dhcp client binding Command | 446 Using the show dhcpv6 client binding Command | 447 Using the show dhcp client statistics Command | 448 Using the show dhcpv6 client statistics Command | 449

9

Phone-Home Client

Obtaining Configurations and Software Image Without User Intervention Using PhoneHome Client | 456

Deploying the Phone-home Client and Zero Touch Provisioning on vSRX | 460

Provision a Virtual Chassis Using the Phone-Home Client | 463 Overview of Phone-Home Provisioning for a Virtual Chassis | 464

How To Enable Phone-Home Provisioning on a Virtual Chassis | 466

Phone-Home Process on a Virtual Chassis | 467 Startup and Request Provisioning Information from PHS | 468 Bootstrap Virtual Chassis Members | 471

xiii

Apply Scripts and New Configuration on the Virtual Chassis | 472 Provisioning Process Completion | 472

Phone-Home Provisioning Status Notifications | 472

Verify Virtual Chassis Status After Phone-Home Provisioning | 475

Troubleshoot Phone-Home Provisioning Issues | 476

10

Automatic Installation of Configuration Files

Understanding Autoinstallation of Configuration Files | 478

Autoinstallation Overview | 478

Autoinstallation Process on Satellite Devices in a Junos Node Unifier Group | 486

Configuring Autoinstallation of Configuration Files | 489 Configuring Autoinstallation of Configuration Files (CLI Procedure) | 489

Example: Configuring Autoinstallation on SRX Series Devices | 492
Requirements | 492 Overview | 493 Configuration | 493 Verification | 496

Verifying Autoinstallation Status | 496

Autoinstalling a Configuration File from a Disk-on-Key USB Memory Stick onto an EX2200 or EX3300 Switch | 498

Configuring Autoinstallation on JNU Satellite Devices | 501

Verifying Autoinstallation on JNU Satellite Devices | 503

Configuring Autoinstallation of Configuration Files on ACX Series | 505 ACX Series Autoinstallation Overview | 506

Before You Begin Autoinstallation on an ACX Series Universal Metro Router | 508

Autoinstallation Configuration of ACX Series Universal Metro Routers | 509

Verifying Autoinstallation on ACX Series Universal Metro Routers | 510

USB Autoinstallation on ACX Series Routers | 511

Autoinstallation on ACX Series Routers in Hybrid Mode Overview | 512

xiv

Prerequisites for Autoinstallation on ACX Series Routers in Hybrid Mode | 514

Autoinstallation Process on a New ACX Series Router in Hybrid Mode | 514

Configuring Autoinstallation of ACX Series Routers in Hybrid Mode | 517

11

Troubleshooting Software Installation

Troubleshooting Software Installation on EX Series Switches | 521

Recovering from a Failed Software Upgrade on an EX Series Switch | 521

Rebooting from the Inactive Partition | 523

Freeing Disk Space for Software Installation | 524

Installation from the Boot Loader Generates 'cannot open package' Error | 525

Troubleshooting a Switch That Has Booted from the Backup Junos OS Image | 527

Managing Disk Space for Junos OS Installation | 528

Verifying PIC Combinations | 529

12

Configuration Statements

auto-configuration | 534

auto-configuration (System) | 535

auto-image-upgrade | 538

auto-snapshot | 540

autoinstallation | 542

autoinstallation (JNU Satellite Devices) | 544

bootp | 546

commit (System) | 548

commit-synchronize-server | 551

configuration-servers | 553

delete-after-commit (JNU Satellites) | 555

file (App Engine Virtual Machine Management Service) | 557

xv

flag (App Engine Virtual Machine Management Service) | 559

interfaces (Autoinstallation) | 562

level (App Engine Virtual Machine Management Service) | 564

license | 566

nextboot | 568

notification (Commit) | 570

traceoptions (App Engine Virtual Machine Management Service) | 571

traceoptions (System License) | 573

usb | 576

vmhost | 578

vmhost management-if disable | 581

vmhost management-if link-mode | 583

vmhost management-if speed | 585

upgrade-mode | 587

13

Operational Commands

clear system login lockout | 593

request app-engine cleanup | 594

request app-engine file-copy (crash | log) from-jhost to-vjunos | 597

request node (offline | online) | 599

request node reboot (re0 | re1) | 601

request system application | 603

request system autorecovery state | 605

request system configuration rescue delete | 608

request system configuration rescue save | 610

request system download abort | 611

xvi
request system download clear | 613 request system download pause | 615 request system download resume | 617 request system download start | 619 request system firmware upgrade | 621 request system halt | 624 request system partition compact-flash | 626 request system power-off | 629 request system reboot | 632 request system reboot (Junos OS with Upgraded FreeBSD) | 643 request system recover | 647 request system scripts add | 651 request system scripts delete | 652 request system scripts rollback | 654 request system snapshot | 655 request system snapshot (Junos OS with Upgraded FreeBSD) | 668 request system snapshot (Maintenance) | 673 request system software abort in-service-upgrade (ICU) | 677 request system software add | 679 request system software add (Maintenance) | 705 request system software configuration-backup | 707 request system software configuration-restore | 709 request system software delete | 711 request system software delete-backup | 717 request system software download | 719

xvii
request system software recover-from-restore-point | 721 request system software restore-point | 723 request system software rollback | 726 request system software rollback (SRX Series) | 733 request system software sync | 735 request system software validate | 741 request system software validate on (Junos OS with Upgraded FreeBSD) | 747 request system software validate-restart | 751 request system storage cleanup | 754 request system storage cleanup (SRX Series) | 776 request system zeroize | 781 rollback | 786 show app-engine crash | 788 show app-engine logs | 790 show chassis usb storage | 794 show system applications | 796 show system autoinstallation status | 808 show system autorecovery state | 811 show system boot-messages | 813 show system auto-snapshot | 824 show system download | 826 show system login lockout | 829 show system rollback | 831 show system snapshot | 833 show system snapshot (Junos OS with Upgraded FreeBSD) | 838

xviii

show system snapshot media | 841

show system software list | 845

show system software restore-point-status | 847

show system software usb-software-version | 849

show system storage partitions | 852

show system ztp | 856

show version | 862

14

VM Host Administration Commands

request vmhost cleanup | 871

request vmhost copy jnode-to-vjunos | 873

request vmhost copy vjunos-to-jnode | 874

request vmhost file-copy | 876

request vmhost halt | 878

request vmhost hard-disk-test | 880

request vmhost power-off | 883

request vmhost power-on | 885

request vmhost reboot | 887

request vmhost snapshot | 889

request vmhost software abort in-service-upgrade | 893

request vmhost software add | 894

request vmhost software in-service-upgrade | 899

request vmhost software rollback | 905

request vmhost software validate | 909

request vmhost zeroize | 910

15

VM Host Monitoring Commands

xix

show vmhost bridge | 916

show vmhost crash | 918

show vmhost hard-disk-test | 920

show vmhost hardware | 922

show vmhost information | 925

show vmhost logs | 927

show vmhost management-if | 929

show vmhost netstat | 931

show vmhost processes | 934

show vmhost resource-usage | 937

show vmhost snapshot | 941

show vmhost status | 943

show vmhost uptime | 946

show vmhost version | 948

16

Configuration Statements from Junos SDK Guide

control-cores | 953

data-cores | 954

data-flow-affinity | 956

destination (Chassis) | 957

extension-provider | 959

forwarding-db-size | 961

hash-key (Chassis) | 963

ip-address-owner | 964

jdaf | 966

object-cache-size | 968

xx
package (Loading on PIC) | 970 policy-db-size | 971 process | 973 process-monitor | 975 resource-cleanup | 977 routing-instances | 978 service-order | 980 syslog (Chassis) | 982 traceoptions (Process Monitor) | 984 traceoptions (Resource Cleanup) | 987 wired-max-processes | 990 wired-process-mem-size | 991

xxi
About This Guide
Use this guide for information relevant to upgrading Junos OS and related software: software packages, upgrading and downgrading Junos OS releases, system backup and recovery procedures, installing and upgrading firmware, storage media, zero touch provisioning.

1 CHAPTER
Junos OS Overview
Junos OS Overview | 2

2
Junos OS Overview
IN THIS SECTION Junos OS Overview | 2
Junos OS is the single operating system that powers Juniper's broad portfolio of physical and virtual networking and security products.
Junos OS Overview
IN THIS SECTION One Operating System | 3 One Modular Software Architecture | 3 Secure Boot | 3 FIPS 140-2 Security Compliance | 4
Juniper Networks provides high-performance network devices that create a responsive and trusted environment for accelerating the deployment of services and applications over a single network. The Junos® operating system (Junos OS) is the foundation of these high-performance networks. Junos OS includes the following architecture variations: · Junos OS FreeBSD 6 on bare metal. This is Junos OS based on a FreeBSD 6 kernel. · Junos OS FreeBSD 10 on bare metal. This is Junos OS based on an upgraded FreeBSD kernel.
Starting with Junos OS Release 15.1, certain hardware platforms run Junos OS with upgraded FreeBSD. Starting in Junos OS Release 16.1, Junos OS with upgraded FreeBSD can run as a guest virtual machine (VM) on a Linux VM host. For more on which platforms run Junos OS with upgraded FreeBSD, see Release Information for Junos OS with Upgraded FreeBSD. · Junos OS Evolved.

3
Unlike other complex, monolithic software architectures, Junos OS incorporates key design and developmental differences to deliver increased network availability, operational efficiency, and flexibility. The following are key advantages to this approach:
One Operating System
Unlike other network operating systems that share a common name but splinter into many different programs, Junos OS is a single, cohesive operating system that is shared across all network devices and product lines. This allows Juniper Networks engineers to develop software features once and share these features across all product lines simultaneously. Because features are common to a single source, they generally are implemented the same way for all product lines, thus reducing the training required to learn different tools and methods for each product. Because all Juniper Networks products use the same code base, interoperability between products is not an issue.
One Modular Software Architecture
Although individual modules of Junos OS communicate through well-defined interfaces, each module runs in its own protected memory space, preventing one module from disrupting another. This separation enables the independent restart of each module as necessary. This is in contrast to monolithic operating systems where a malfunction in one module can ripple to other modules and cause a full system crash or restart. This modular architecture then provides for high performance, high availability, security, and device scalability not found in other operating systems.
The Junos OS is preinstalled on your Juniper Networks device when you receive it from the factory. Thus, when you first power on the device, all software starts automatically. You simply need to configure the software so that the device can participate in the network.
You can upgrade the device software as new features are added or software problems are fixed. You normally obtain new software by downloading the software installation packages from the Juniper Networks Support Web page onto your device or onto another system on your local network. You then install the software upgrade onto the device.
Juniper Networks routing platforms run only binaries supplied by Juniper Networks, and currently do not support third-party binaries. Each Junos OS image includes a digitally signed manifest of executables that are registered with the system only if the signature can be validated. Junos OS will not execute any binary without a registered signature. This feature protects the system against unauthorized software and activity that might compromise the integrity of your device.
Secure Boot
Secure Boot is a significant system security enhancement based on the UEFI standard (see www.uefi.org). It works by safeguarding the BIOS itself from tampering or modification and then maintaining that protection throughout the boot process.

4
The Secure Boot process begins with Secure Flash, which ensures that unauthorized changes cannot be made to the firmware. Authorized releases of Junos OS carry a digital signature produced by either Juniper Networks directly or one of its authorized partners. At each point of the boot-up process, each component verifies the next link is sound by checking the signature to ensure that the binaries have not been modified. The boot process cannot continue unless the signature is correct. This "chain of trust" continues until the operating system takes control. In this way, overall system security is enhanced, increasing resistance to some firmware-based persistent threats. Figure 1 shows a simplified version of this "chain of trust."
Secure Boot requires no actions on your part to implement. It is implemented on supported hardware by default. For information on which Junos OS releases and hardware support Secure Boot, see Feature Explorer and enter Secure Boot.
FIPS 140-2 Security Compliance
For advanced network security, a special version of Junos OS, called Junos-FIPS 140-2, is available. Junos-FIPS 140-2 provides customers with software tools to configure a network of Juniper Networks devices in a FIPS environment. FIPS support includes: · Upgrade package to convert Junos OS to Junos-FIPS 140-2 · Revised installation and configuration procedures · Enforced security for remote access · FIPS user roles (Crypto Officer, User, and Maintenance) · FIPS-specific system logging and error messages · IPsec configuration for Routing Engine­to­Routing Engine communication · Enhanced password creation and encryption

5
Starting in Junos OS Release 15.1, Junos-FIPS is packaged in a domestic image only: a single Junos OS image supports both domestic and FIPS features. Users that have the FIPS credentials and permission to login can flip between a regular Junos image and FIPS image.
NOTE: Junos-FIPS has special password requirements. FIPS passwords must be between 10 and 20 characters in length. Passwords must use at least three of the five defined character sets (uppercase letters, lowercase letters, digits, punctuation marks, and other special characters). If Junos-FIPS is installed on the device, you cannot configure passwords unless they meet this standard.

2 CHAPTER
System Back Up and Recovery
Backing Up an Installation Using Snapshots | 7 Recovery Using an Emergency Boot Device | 26 Rescue and Recovery of Configuration File | 33 Recovery of Junos OS | 42 How to Recover Junos OS with Upgraded FreeBSD | 49 Autorecovery of Configuration, Licenses, and Disk Information on SRX Series Devices | 57

7
Backing Up an Installation Using Snapshots
IN THIS SECTION Understanding How to Back Up an Installation on Switches | 7 Creating a Snapshot and Using It to Boot a QFX Series Switch | 9 Creating a Snapshot and Using It to Boot an EX Series Switch | 14 Creating a Snapshot and Using It to Boot an SRX Series device | 15 Creating a Snapshot and Using It to Boot an ACX Series Router | 21
The installation process removes all stored files on the device except the juniper.conf and SSH files. Therefore, you should back up your current configuration in case you need to return to the current software installation after running the installation program. You can also recover the configuration file and the Junos OS if required.
Understanding How to Back Up an Installation on Switches
IN THIS SECTION Understanding System Snapshot on QFX Switches | 8 Understanding System Snapshot on EX Series Switches | 8
You can create copies of the software running on a switch using the system snapshot feature. The system snapshot feature takes a "snapshot" of the files currently used to run the switch--the complete contents of the /config and /var directories, which include the running Junos OS, the active configuration, and the rescue configuration--and copies all of these files into an alternate (internal, meaning internal flash, or an external, meaning USB flash) memory source. You can then use this snapshot to boot the switch at the next boot up or as a backup boot option. On devices running Junos OS Evolved, this command only copies the contents of the /soft directory, which includes the running version of Junos OS Evolved.

8
Understanding System Snapshot on QFX Switches
NOTE: On QFX3500 and QFX3600 switches running Enhanced Layer 2 Software, all of the directories that reside in the "/" partition are read only.
NOTE: System snapshot is not supported on QFX10000 switches.
You can only use snapshots to move files to external memory if the switch was booted from internal memory, or to move files to internal memory if the switch was booted from external memory. You cannot create a snapshot in the memory source that booted the switch even if the snapshot is being created on a different partition in the same memory source. Snapshots are particularly useful for moving files onto USB flash drives. You cannot use the copy command or any other file-moving technique to move files from an internal memory source to USB memory on the switch. System snapshots on the switch have the following limitations: · You cannot use snapshots to move files to any destination outside of the switch other than an
installed external USB flash drive. · Snapshot commands are always executed on a local switch.
Understanding System Snapshot on EX Series Switches
The switch can boot from either internal flash media or external (USB) flash media. The contents of the snapshot vary depending on whether you create the snapshot on the media that the switch booted from or on the media that it did not boot from. Snapshots are particularly useful for moving files onto USB flash drives. You cannot use the copy command or any other file-moving technique to move files from an internal memory source to USB memory on the switch. · If you create the snapshot on the media that the switch did not boot from, the following partitions on
the boot media are included in the snapshot: root, altroot, var, var/tmp, and config. The root partition is the primary boot partition, and the altroot partition is the backup boot partition. · If you create the snapshot on the media that the switch booted from, the root partition that the switch booted from is copied to the alternate root partition. The var, var/tmp, and config partitions are not copied as part of the snapshot because they already exist on the boot media.

9
The system snapshot feature has the following limitations: · You cannot use snapshots to move files to any destination outside the switch other than an installed
external USB flash drive or switches that are members of the same Virtual Chassis as the switch on which you created the snapshot. · Snapshot commands, like all commands executed on a Virtual Chassis, are executed on the local member switch. If different member switches request the snapshot, the snapshot command is pushed to the Virtual Chasis member creating the snapshot and is executed on that member, and the output is then returned to the switch that initiated the process. For instance, if the command to create an external snapshot on member 3 is entered on member 1, the snapshot of internal memory on member 3 is taken on external memory on member 3. The output of the process is seen on member 1. No files move between the switches.
Creating a Snapshot and Using It to Boot a QFX Series Switch
IN THIS SECTION Creating a Snapshot on an External USB Flash Drive and Using It to Boot a QFX Series Switch | 10 Creating a Snapshot and Using It to Boot a QFX3500 and QFX3600 Series Switch | 11
The system snapshot feature takes a " snapshot" of the files currently used to run the device-- the complete contents of the /config directories, which include the running Juniper Networks Junos OS, the active configuration, and the rescue configuration, as well as the host OS-- and copies all of these files into an external USB flash drive.
NOTE: EX4600 and QFX Series products except for QFabric only support snapshot via external USB. QFabric does not support request system snapshot at all.
You can use the snapshot to boot the device at the next bootup or as a backup boot option. The system snapshot feature is especially effective as a bootup option after a partition corruption, as it is the only recovery option that allows you to completely restore the Junos OS and configuration in the event of a corrupted partition on a switch.

10
NOTE: EX4600 and most QFX Series switches support snapshot via external USB.
NOTE: The following products do not support system snapshot: QFabric and QFX5200 and QFX10000 switches.
This topic includes the following tasks:
Creating a Snapshot on an External USB Flash Drive and Using It to Boot a QFX Series Switch
A snapshot can be created on an external USB flash drive after a device is booted using files stored in internal memory. Ensure that you have the following tools and parts available before creating a snapshot on an external USB flash drive: · An external USB flash drive that meets the device USB port specifications. See USB Port
Specifications for the QFX Series. To create a snapshot on the external USB flash drive and use it to boot the device: 1. Insert the external USB flash drive. 2. Issue the request system snapshot command.
user@device> request system snapshot fpc0:
-------------------------------------------------------------------------Starting snapshot to usb (/dev/da0) Creating snapshot on the host .. Copying bootable disk image from host .. Writing to usb (/dev/da0) .. Copying 'Host OS' to '/dev/da0s1' .. (this may take a few minutes)
Copying 'JUNOS' to '/dev/da0s1' .. (this may take a few minutes) The following filesystems were archived: / /config Host-OS
3. (Optional) Perform this step if you want to boot the device now using the snapshot stored on the external USB flash drive. If you created the snapshot as a backup, do not perform this step. · Insert the external USB flash drive.

11
· Power cycle the device. The external USB flash drive is detected.
· The software prompts you with the following options:
Junos Snapshot Installer - (c) Juniper Networks 2013 Reboot Install Junos Snapshot [13.2-20131115_x_132_x51_vjunos.0 Boot to host shell [debug]
· Select Install Junos Snapshot to install the snapshot located on the external USB flash drive to the device. The device copies the software from the external USB flash drive, occasionally displaying status messages. When the software is finished being copied from the external USB flash drive to the device, the device then reboots from the internal flash storage on which the software was just installed. When the reboot is complete, the device displays the Junos OS login prompt:
root@device#
Creating a Snapshot and Using It to Boot a QFX3500 and QFX3600 Series Switch
IN THIS SECTION Creating a Snapshot on a USB Flash Drive and Using It to Boot the Switch | 12 Creating a Snapshot on an Internal Flash Drive and Using it to Boot the Switch | 13 Creating a Snapshot on the Alternate Slice of the Boot Media | 13
The system snapshot feature takes a "snapshot" of the files currently used to run the QFX Series switch --the complete contents of the /config and /var directories, which include the running Juniper Networks Junos OS, the active configuration, and the rescue configuration--and copies all of these files into an alternate (internal, meaning internal flash, or an external, meaning USB flash) memory source. You can then use these snapshots to boot the switch at the next bootup or as a backup boot option.

12
The system snapshot feature is especially effective as a bootup option after a partition corruption, as it is the only recovery option that allows you to completely restore the Junos OS and configuration in the event of a corrupted partition. This topic includes the following tasks: Creating a Snapshot on a USB Flash Drive and Using It to Boot the Switch
NOTE: Creating a snapshot is not supported on QFX10000 switches.
A snapshot can be created on USB flash memory after a switch is booted using files stored in internal memory. Ensure that you have the following tools and parts available before creating a snapshot on a USB Flash drive: · A USB flash drive that meets the QFX Series switch USB port specifications. See USB Port
Specifications for the QFX Series. To create a snapshot on USB flash memory and use it to boot the switch: 1. Place the snapshot into USB flash memory:
user@switch> request system snapshot partition
NOTE: This example uses the partition option. If you have already created a partition for the snapshot, you don't need to use the partition option.
2. (Optional) Perform this step if you want to boot the switch now using the snapshot stored on the external USB flash drive. If you created the snapshot as a backup, do not perform this step. · To reboot the switch using the most recently created snapshot:
user@switch> request system reboot
· To reboot the switch using a snapshot in a specific partition on the USB flash drive:
user@switch> request system reboot slice 1

13
Creating a Snapshot on an Internal Flash Drive and Using it to Boot the Switch
A snapshot can be created on internal memory after a switch is booted using files stored in external memory. To create a snapshot in internal memory and use it to boot the switch: 1. Place the snapshot files in internal memory:
user@switch> request system snapshot partition
NOTE: This example uses the partition option. If you have already created a partition for the snapshot, you don't need to use the partition option. 2. (Optional) Perform this step if you want to boot the switch now using the newly created snapshot. If you created the snapshot as a backup, do not perform this step. · To reboot the switch using the most recently created snapshot:
user@switch> request system reboot
· To reboot the switch using a snapshot in a specific partition in internal memory:
user@switch> request system reboot slice 1
Creating a Snapshot on the Alternate Slice of the Boot Media The alternate slice of the boot media contains a backup software image that the switch can boot from if it is unable to boot from the primary slice. When you upgrade software, the new software image gets copied only to the primary slice of the boot media. To create a snapshot of the currently booted software image on the backup slice of the boot media:
user@switch> request system snapshot slice alternate After the system boots up, you will see the following message before the login prompt: WARNING: THIS DEVICE HAS BOOTED FROM THE BACKUP JUNOS IMAGE

14
It is possible that the primary copy of JUNOS failed to boot up properly, and so this device has booted up from the backup copy. Please re-install JUNOS to recover the primary copy in case it has been corrupted. The system will generate an alarm indicating that the switch has booted from the backup slice.
Creating a Snapshot and Using It to Boot an EX Series Switch
IN THIS SECTION Creating a Snapshot on a USB Flash Drive and Using It to Boot the Switch | 14
The system snapshot feature takes a "snapshot" of the files currently used to run the switch and copies them to an alternate storage location. You can then use this snapshot to boot the switch at the next bootup or as a backup boot option. This topic includes the following tasks:
Creating a Snapshot on a USB Flash Drive and Using It to Boot the Switch
You can create a snapshot on USB flash memory after a switch is booted by using files stored in internal memory. Ensure that you have the following tools and parts available before creating a snapshot on a USB flash drive: · A USB flash drive that meets the switch USB port specifications. See USB Port Specifications for an
EX Series Switch. To create a snapshot on USB flash memory and use it to boot the switch: 1. Place the snapshot into USB flash memory:
user@switch> request system snapshot partition media usb

15 2. (Optional) Perform this step if you want to boot the switch now using the snapshot stored on the
USB flash drive. user@switch> request system reboot media usb
Creating a Snapshot and Using It to Boot an SRX Series device
IN THIS SECTION Creating a Snapshot and Using It to Boot an SRX Series device | 15 Backing Up the Current Installation on SRX Series Devices | 18
Creating a Snapshot and Using It to Boot an SRX Series device
IN THIS SECTION Requirements | 15 Overview | 16 Configuration | 17
This example shows how to configure a boot device. Requirements Before you begin, ensure that the backup device has a storage capacity of at least 1 GB. See "Ensuring Sufficient Disk Space for Junos OS Upgrades on SRX Devices" on page 98.

16
Overview
IN THIS SECTION Topology | 16
You can configure a boot device to replace the primary boot device on your SRX Series device or to act as a backup boot device. Use either the J-Web user interface or the CLI to take a snapshot of the configuration currently running on the device, or of the original factory configuration and a rescue configuration, and save it to an alternate medium.
NOTE: For media redundancy, we recommend that you keep a secondary storage medium attached to the SRX Series device and updated at all times.
If the primary storage medium becomes corrupted and no backup medium is in place, you can recover the primary internal media from the TFTP installation. You can also configure a boot device to store snapshots of software failures for use in troubleshooting.
NOTE: You cannot copy software to the active boot device.
NOTE: After a boot device is created with the default factory configuration, it can operate only in an internal media slot.
This example configures a boot device to back up the currently running and active file system partitions by rebooting from internal media and including only files shipped from the factory. Topology

17
Configuration
IN THIS SECTION Procedure | 17
Procedure CLI Quick Configuration To quickly configure this section of the example, copy the following commands, paste them into a text file, remove any line breaks, change any details necessary to match your network configuration, copy and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode. From operational mode, enter:
user@host> request system snapshot partition media internal factory
GUI Quick Configuration Step-by-Step Procedure To configure a boot device: 1. In the J-Web user interface, select Maintain>Snapshot. 2. On the Snapshot page, specify the boot device to copy the snapshot to. From the Target Media list,
select the internal boot device. 3. Select the Factory check box to copy only default files that were loaded on the internal media when
it was shipped from the factory, plus the rescue configuration if one has been set. 4. Select the Partition check box to partition the medium that you are copying the snapshot to. This
process is usually necessary for boot devices that do not already have software installed on them. 5. Click Snapshot. 6. Click OK to check your configuration and save it as a candidate configuration.

18
7. If you are done configuring the device, click Commit Options>Commit. Step-by-Step Procedure The following example requires you to navigate various levels in the configuration hierarchy. For instructions on how to do that, see Using the CLI Editor in Configuration Mode. 1. To configure a boot device:
user@host> request system snapshot partition media internal factory
Results From configuration mode, confirm your configuration by entering the show system snapshot media internal command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it.
user@host> show system snapshot media internal

Information for snapshot on

internal (/dev/ad0s1a) (backup)

Creation date: Oct 9 13:30:06 2009

JUNOS version on snapshot:

junos : 10.0B3.10-domestic

Information for snapshot on

internal (/dev/ad0s2a) (primary)

Creation date: Jan 6 15:45:35 2010

JUNOS version on snapshot:

junos : 10.2-20091229.2-domestic

If you are done configuring the device, enter commit from configuration mode.
Backing Up the Current Installation on SRX Series Devices

IN THIS SECTION
Backing Up the Current Installation on SRX5800, SRX5600, and SRX5400 Devices | 19 Backing Up the Current Installation on SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M, SRX3400, and SRX3600 Devices | 19

19
Configuring External CompactFlash for SRX650 Devices | 20
This topic includes the following sections:
Backing Up the Current Installation on SRX5800, SRX5600, and SRX5400 Devices
Back up the current installation so that you can return to the current software installation. The installation process using the installation package (jinstall*, for example) removes all stored files on the device except the juniper.conf and SSH files. Therefore, you should back up your current configuration in case you need to return to the current software installation after running the installation program. To back up Junos OS on the SRX Series devices, issue the request system snapshot CLI operational command. This command saves the current software installation on the hard disk, external USB storage media device, or solid-state drive (SSD). When the request system snapshot command is issued, the /root file system is backed up to /altroot, and /config is backed up to /altconfig. The /root and /config file systems are on the devices's CompactFlash card, and the /altroot and /altconfig file systems are on the devices's hard disk or or solidstate drive (SSD). When the backup is completed, the current and backup software installations are identical. To copy the files to the device's hard disk or solid-state drive (SSD), use the following command: user@host> request system snapshot media
Backing Up the Current Installation on SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M, SRX3400, and SRX3600 Devices
On SRX Series devices, you can backup the current Junos OS image and configuration files onto a media (such as a USB or CompactFlash) so that you can retrieve it back if something goes wrong. To back up the currently running and active file system partitions on the device, use the following command: user@host> request system snapshot media Following options are supported: · internal-- Copies the snapshot to internal media. · usb-- Copies the snapshot to the USB storage device. This is the default option for SRX300, SRX320,
SRX340, SRX345, SRX380, and SRX550M devices.

20
· external-- Copies the snapshot to an external storage device. This option is available for the compact flash on the SRX650 Services Gateway only.
Configuring External CompactFlash for SRX650 Devices
Following procedure shows how to backup current installation on an SRX650 device.
The SRX650 Services Gateway includes the following 2 GB CompactFlash (CF) storage device: · The Services and Routing Engine (SRE) contains a hot-pluggable external CF storage device used to
upload and download files. · The chassis contains an internal CF used to store the operating system. By default, only the internal CF is enabled and an option to take a snapshot of the configuration from the internal CF to the external CF is not supported. This can be done only by using a USB storage device. To take a snapshot of the configuration from the external CF: 1. Take a snapshot from the internal CF to a USB storage device using the request system snapshot
media usb command. 2. Reboot the device from the USB storage device using the request system reboot media usb
command. 3. Go to the U-boot prompt. 4. Stop at U-boot and set the following variables:
set ext.cf.pref 1 save reset
5. Once the system is booted from the USB storage device, take a snapshot from the external CF using the request system snapshot media external command.
NOTE: Once the snapshot is taken on the external CF, we recommend that you set the ext.cf.pref to 0 at the U-boot prompt.

21
Creating a Snapshot and Using It to Boot an ACX Series Router
IN THIS SECTION Understanding System Snapshot on an ACX Series Router | 21 Example: Taking a Snapshot of the Software and Configuration | 22
Understanding System Snapshot on an ACX Series Router
The system snapshot feature enables you to create copies of the software running on an ACX Series router. You can use the system snapshot feature to take a "snapshot" of the files currently used to run the router--the complete contents of the root (/) and /config directories, which include the running Juniper Networks Juniper operating system (Junos OS) and the active configuration--and copy all of these files to another media, such as a universal serial bus (USB) storage device, the active slice of a dual-root partitioned router, or the alternate slice of a dual-root partitioned router.
NOTE: Junos OS automatically uses the backup software if the currently running software goes bad. For example, if the da0s1 slice goes bad, Junos OS automatically comes up using the da0s2 slice, and takes a snapshot of the da0s2 slice and copies it to the da0s1 slice if the auto snapshot functionality is configured, which is disabled by default. However, you can also do this manually using the system snapshot feature.
NOTE: In ACX5048 and ACX5096 routers, the system snapshot feature is applicable only when a USB storage device is used.
Typically, you can take a snapshot prior to the upgrade of an image on the dual internal NAND flash device (da0s1 or da0s2), or to remedy a bad image, thereby preventing the bad image from rendering the system useless. A snapshot to another media ensures that the device can boot from the other media in case the system does not boot up from the current image. You can take a snapshot of the currently running software and configuration on a router in the following situations: · The router's active slice (for example, da0s1) is updated with a new Junos OS image (using the jinstall
package). In such a case, you must update the other slice (da0s2) with the new image.

22
NOTE: The active slice can be da0s1 or da0s2.
· The router's active slice (for example, da0s1) is corrupted and the router is rebooted from the backup slice (that is, from da0s2). Therefore, you must restore a new image on the active slice--that is, on da0s1.
· Both slices of the router's dual internal NAND flash device are corrupted and the router continues trying to reboot. In this situation, you can insert a USB storage device, boot the router from that device, and restore the NAND flash device slices--da0s1 and da0s2.
NOTE: Before you attempt to take a snapshot from the USB storage device, ensure that the USB storage device contains an image of Junos OS from which the router can boot up.
SEE ALSO request system snapshot (ACX Series)
Example: Taking a Snapshot of the Software and Configuration
IN THIS SECTION Requirements | 26 Overview | 26
This example includes six scenarios in which you can take a snapshot of the currently running software and configuration on an ACX Series router, prior to the upgrade of an image or to remedy a bad image, thereby preventing the bad image from rendering the system useless. Taking a Snapshot Step-by-Step Procedure Scenario: To take a snapshot from a NAND flash device slice to a USB storage device:

23

1. Boot up the router from the NAND flash device and make sure that a formatted USB storage device is plugged in to the router's USB port. The USB storage device must be formatted for the root (/) and /config directories.
2. Issue the request system snapshot command.

user@host> request system snapshot Verifying compatibility of destination media partitions... Running newfs (254MB) on usb media / partition (da1s1a)... Running newfs (47MB) on usb media /config partition (da1s1e)... Copying '/dev/da0s2a' to '/dev/da1s1a' .. (this may take a few minutes) Copying '/dev/da0s2e' to '/dev/da1s1e' .. (this may take a few minutes) The following filesystems were archived: / /config
The root (/) and /config directories from the currently mounted NAND flash slice are copied to the USB storage device.
Step-by-Step Procedure
Scenario: To take a snapshot from a NAND flash device slice to a USB storage device with formatting: 1. Boot up the router from the NAND flash device and make sure that a USB storage device is plugged
in to the router's USB port.
NOTE: Formatting a USB storage device deletes all the data on the USB storage device.

2. Issue the request system snapshot partition command.

user@host> request system snapshot partition clearing current label... Partitioning usb media (da1) ... Partitions on snapshot:

Partition Mountpoint Size Snapshot argument

a

/

312MB root-size

e

/config

47MB config-size

f

/var

620MB var-size

Running newfs (312MB) on usb media / partition (da1s1a)...

Running newfs (47MB) on usb media /config partition (da1s1e)...

Running newfs (620MB) on usb media /var partition (da1s1f)...

24
Copying '/dev/da0s2a' to '/dev/da1s1a' .. (this may take a few minutes) Copying '/dev/da0s2e' to '/dev/da1s1e' .. (this may take a few minutes) The following filesystems were archived: / /config
After the USB storage device is formatted, the root (/) and /config directories from the currently mounted NAND flash slice are copied to the USB storage device.
Step-by-Step Procedure
Scenario: To take a snapshot from the active slice of the NAND flash device to the alternate slice: 1. Boot up the router from the NAND flash device. 2. Issue the request system snapshot slice alternate command.
user@host> request system snapshot slice alternate Verifying compatibility of destination media partitions... Running newfs (439MB) on internal media / partition (da0s1a)... Running newfs (46MB) on internal media /config partition (da0s1e)... Copying '/dev/da0s2a' to '/dev/da0s1a' .. (this may take a few minutes) Copying '/dev/da0s2e' to '/dev/da0s1e' .. (this may take a few minutes) The following filesystems were archived: / /config
The root (/) and /config directories from the currently mounted NAND flash slice are copied to the other slice.
Step-by-Step Procedure
Scenario: To take a snapshot from an active slice of the NAND flash device to the alternate slice after partitioning: 1. Boot up the router from the NAND flash device. 2. Issue the request system snapshot partition slice alternate command.
user@host> request system snapshot partition slice alternate Verifying compatibility of destination media partitions... Running newfs (439MB) on internal media / partition (da0s1a)... Running newfs (46MB) on internal media /config partition (da0s1e)... Copying '/dev/da0s2a' to '/dev/da0s1a' .. (this may take a few minutes) Copying '/dev/da0s2e' to '/dev/da0s1e' .. (this may take a few minutes) The following filesystems were archived: / /config

25
The BSD label (disk partitioning information) for the active flash slice is installed and then the root (/) and /config directories from the currently mounted NAND flash slice are copied to the other slice.
Step-by-Step Procedure
Scenario: To take a snapshot from a USB storage device to the active slice of the NAND flash device: 1. Boot up the router from a USB storage device containing the required Junos OS image. 2. Issue the request system snapshot command.
user@host> request system snapshot Verifying compatibility of destination media partitions... Running newfs (439MB) on internal media / partition (da0s1a)... Running newfs (46MB) on internal media /config partition (da0s1e)... Copying '/dev/da1s1a' to '/dev/da0s1a' .. (this may take a few minutes) Copying '/dev/da1s1e' to '/dev/da0s1e' .. (this may take a few minutes) The following filesystems were archived: / /config
The root (/) and /config directories from the USB storage device are copied to the active NAND flash slice.
Step-by-Step Procedure
Scenario: To take a snapshot from a USB storage device to the active slice of the NAND flash device after partitioning: 1. Boot up the router from a USB storage device containing the required Junos OS image. 2. Issue the request system snapshot partition command.
user@host> request system snapshot partition Verifying compatibility of destination media partitions... Running newfs (439MB) on internal media / partition (da0s1a)... Running newfs (46MB) on internal media /config partition (da0s1e)... Copying '/dev/da1s1a' to '/dev/da0s1a' .. (this may take a few minutes) Copying '/dev/da1s1e' to '/dev/da0s1e' .. (this may take a few minutes) The following filesystems were archived: / /config
The BSD label (disk partitioning information) for the active flash slice is installed and then the root (/) and /config directories from the USB storage device are copied to the active NAND flash slice.

26
Requirements This example uses the following hardware and software components: · One ACX Series router · Junos OS Release 12.2 or later
Overview In this example, the request system snapshot command is used to take a copy of the currently running software and configuration on another media--for example, a universal serial bus (USB) storage device, the active slice (da0s1 or da0s2) of a dual-root partitioned router, or the alternate slice (da0s1 or da0s2) of a dual-root partitioned router. A snapshot to another media ensures that the device can boot from the other media in case the system does not boot up from the current image.
CAUTION: After you run the request system snapshot command, you cannot return to the previous version of the software, because the running and backup copies of the software are identical.
SEE ALSO Understanding System Snapshot on an ACX Series Router request system snapshot (ACX Series)
Recovery Using an Emergency Boot Device
IN THIS SECTION Creating an Emergency Boot Device for Routers | 27 Creating an Emergency Boot Device for QFX Series Switches | 28 Recovering the Installation Using an Emergency Boot Device | 30 Performing a Recovery Installation | 32

27
If Junos OS software is damaged on your device, the emergency boot device helps you to recover the software.
Creating an Emergency Boot Device for Routers
If the device's Junos OS software is damaged in some way that prevents Junos OS software from loading completely, you can use the emergency boot device to revive the device. The emergency boot device repartitions the primary disk and reloads a fresh installation of Junos OS software. The procedures outlined in this section discuss how to create an emergency boot device for any ACX Series, M Series, MX Series, T Series, TX Matrix, and TX Matrix Plus router. To create an emergency boot device: 1. Use FTP to copy the installation media into the router's /var/tmp directory. 2. Insert the PC Card into the external PC Card slot or USB storage device into the USB port. 3. In the UNIX shell, navigate to the /var/tmp directory:
start shell cd /var/tmp
4. Log in as su:
su [enter] password: [enter SU password]
5. For Junos OS with upgraded FreeBSD only, expand the image, for example:
gzip -d installMedia.img.gz
where installMedia refers to the installation media downloaded into the /var/tmp directory. For example, for Junos OS with upgraded FreeBSD, the filename might be junos-install-media-usb-mxx86-64-16.1R2.11.img.gz. (To determine which platforms use Junos OS with upgraded FreeBSD, see Release Information for Junos OS with Upgraded FreeBSD.) 6. Issue the following commands:

28
· For Junos OS with upgraded FreeBSD:
dd if=/dev/zero of=/dev/externalDrive count=20 dd if=installMedia.img of=/dev/externalDrive bs=256k
· For Junos OS:
dd if=/dev/zero of=/dev/externalDrive count=20 dd if=installMedia of=/dev/externalDrive bs=64k
where: · externalDrive--Refers to the removable media name of the emergency boot device. For example,
the removable media name for an emergency boot device on the M120 router is da0 for both Routing Engines. For the names of the removable media, see the table in"Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, PTX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers)" on page 394. · installMedia--Refers to the installation media downloaded into the /var/tmp directory. For example, the filename might be install-media-9.0R2.10­domestic for Junos OS or, for Junos OS with upgraded FreeBSD, junos-install-media-usb-mx-x86-64-16.1R2.11.img (unzipped). (To determine which platforms use Junos OS with upgraded FreeBSD, see Release Information for Junos OS with Upgraded FreeBSD.) 7. Log out as su:
exit
Creating an Emergency Boot Device for QFX Series Switches
Before you begin, you need to download the installation media image for your device and Junos OS release from https://www.juniper.net/customers/support/ . If Junos OS on the device is damaged in some way that prevents the software from loading properly, you can use an emergency boot device to repartition the primary disk and load a fresh installation of Junos OS. Use the following procedure to create an emergency boot device.

29
NOTE: You can create the emergency boot device on another Juniper Networks switch or router, or any laptop or desktop PC that supports Linux. The steps you take to create the emergency boot device vary, depending on the device.
To create an emergency boot device: 1. Use FTP to copy the installation media image into the /var/tmp directory on the device. 2. Insert a USB storage device into the USB port. 3. From the Junos OS command-line interface (CLI), start the shell:
user@device> start shell % 4. Use the gunzip command to unzip the image file. 5. Switch to the root account using the su command:
% su Password: password
NOTE: The password is the root password for the device. If you logged in to the device as the root user, you do not need to perform this step.
6. Enter the following command on the device:
root@device% dd if=/var/tmp/filename of=/dev/da1 bs=1m The device writes the installation media image to the USB storage device:
root@device% dd if=install-media-qfx-5e-15.1X53-D30.5-domestic.img of=/dev/ da0 bs=1m 1399+0 records in 1399+0 records out 1466957824 bytes transferred in 394.081902 secs (3722469 bytes/sec)

30
7. Log out of the shell:
root@device% exit % exit user@device>
Recovering the Installation Using an Emergency Boot Device
If Junos OS on your device is damaged in some way that prevents the software from loading correctly, you may need to perform a recovery installation using an emergency boot device (for example, a USB flash drive) to restore the default factory installation. Once you have recovered the software, you need to restore the device configuration. You can either create a new configuration as you did when the device was shipped from the factory, or if you saved the previous configuration, you can simply restore that file to the device. If at all possible, you should try to perform the following steps before you perform the recovery installation: 1. Ensure that you have an emergency boot device to use during the installation. See Creating an
Emergency Boot Device for QFX Series Switches for information on how to create an emergency boot device. 2. Copy the existing configuration in the file /config/juniper.conf.gz from the device to a remote system, such as a server, or to an emergency boot device. For extra safety, you can also copy the backup configurations (the files named /config/juniper.conf.n, where n is a number from 0 through 9) to a remote system or to an emergency boot device. You can use the system snapshot feature to complete this step. The system snapshot feature takes a "snapshot" of the files currently used to run the QFX Series switch--the complete contents of the / config and /var directories, which include the running Juniper Networks Junos OS, the active configuration, and the rescue configuration--and copies all of these files into a memory source. See Creating a Snapshot and Using It to Boot a QFX Series Switch.
NOTE: System snapshot is not supported on QFX10000 and QFX5200 switches.
CAUTION: The recovery installation process completely overwrites the entire contents of the internal flash storage.

31
3. Copy any other stored files to a remote system as desired. To reinstall Junos OS: 1. Insert the emergency boot device into the device. 2. Power cycle the device.
The emergency boot device is detected. At this time, you can load the Junos OS from the emergency boot device onto the internal flash storage. 3. The software prompts you with the following option if you have a snapshot saved on the emergency boot device:
Junos Snapshot Installer - (c) Juniper Networks 2013 Reboot Install Junos Snapshot [14.1X53-D11_vjunos.61] Boot to host shell
[debug] 
Select Install Junos Snapshot to install the snapshot. The software prompts you with the following option if you have Junos OS software from the factory installed on the emergency boot device.
Juniper Linux Installer - (c) Juniper Networks 2014 Reboot Install Juniper Linux Platform Boot to host shell [debug]
Select Install Juniper Linux Platform to install the Junos OS software from the emergency boot device. 4. The device copies the software from the emergency boot device, occasionally displaying status messages. Copying the software can take up to 12 minutes. When the software is finished being copied from the emergency device to the device, the device reboots from the internal flash storage on which the software was just installed. When the reboot is complete, the device displays the Junos OS login prompt:
root@switch#

32
5. Create a new configuration as you did when the device was shipped from the factory, or restore the previously saved configuration file to the device.
6. Remove the emergency boot device.
Performing a Recovery Installation
If the device's software is corrupted or otherwise damaged, you may need to perform a recovery installation, using the emergency boot device to restore the default factory installation. Once you have recovered the software, you will need to restore the router or switch's configuration. You can either create a new configuration as you did when the device was shipped from the factory, or if you saved the device's previous configuration, you can simply restore that file to the system. Depending on the situation, you should try to perform the following steps before you perform the recovery installation: 1. Ensure you have an emergency recovery disk to use during the installation. When the router or
switch is first shipped, an emergency recovery disk is provided with it. For instructions on creating an emergency boot device, see "Creating an Emergency Boot Device for Routers" on page 27 2. Copy the existing configuration in the file /config/juniper.conf.gz from the device to a remote system. For extra safety, you can also copy the backup configurations (the files named /config/ juniper.conf.n, where n is a number from 0 through 9).
CAUTION: The recovery installation process completely overwrites the entire contents of the fixed storage media.
3. Copy any other stored files to a remote system as desired. To reinstall Junos OS: 1. Insert the removable media emergency boot device into the device.
NOTE: You can store a configuration on installation media such as a PC Card or USB stick.
2. Reboot the device. If the CLI is still active, issue the request system reboot command from command mode to reboot the device.

33
If the CLI is not working, manually power off the device using the main power switch, wait 10 seconds, and then power the device back on. 3. When the software prompts you with the following question, type y:
NOTE: Introduced in Junos OS Release 15.1, Junos OS with upgraded FreeBSD does not display the following warning. To determine which platforms use Junos OS with upgraded FreeBSD, see Release Information for Junos OS with Upgraded FreeBSD.
WARNING: The installation will erase the contents of your disk. Do you wish to continue (y/n)? y
The device copies the software from the removable media emergency boot device onto your system, occasionally displaying status messages. Copying the software can take up to 45 minutes, depending on the device. When the process is complete, the router boots into Amnesiac state and the login prompt is displayed. 4. Remove the removable media emergency boot device. 5. Log in as root on the device's console port and issue the request system reboot command from command mode to reboot the device. The device reboots from the boot device on which the software was just installed. When the reboot is complete, the device displays the login prompt. 6. Create a new configuration as you did when the device was shipped from the factory, or restore a previously saved configuration file to the system. For more information, see Creating a New Configuration on a Single Routing Engine, Creating a New Configuration with Redundant Routing Engines, and "Restoring a Saved Configuration".
Rescue and Recovery of Configuration File
IN THIS SECTION Saving and Reverting a Rescue Configuration File | 34 Copy Backup Configurations and Restoring a Saved Configurations | 39

34
Reverting to the Default Factory Configuration by Using the request system zeroize Command | 42
In the event of software failure, a rescue configuration helps to load a known working configuration. No need to remember the rollback number; if you saved a configuration, you can use it anytime when needed.
Saving and Reverting a Rescue Configuration File
IN THIS SECTION Saving a Rescue Configuration File | 34 Reverting to the Rescue Configuration | 38
Saving a Rescue Configuration File
IN THIS SECTION Saving a Rescue Configuration | 35 Validating the Rescue Configuration | 35 Copying the Configuration to a Remote Server | 36 Rolling Back to Troubleshoot the Failed Configuration | 37 Rolling Back to the Rescue Configuration | 37 Deleting an Existing Rescue Configuration | 38
A rescue configuration file is helpful in the event that your device's configuration file has been misconfigured. A rescue configuration allows you to define a known working configuration or a configuration with a known state that you can roll back to at any time. This alleviates the necessity of having to remember the rollback number with the rollback command. You can restore the device to this

35
rescue configuration to bring the device back online. If you save this file off the device, the rescue configuration can also be used to restore your device in the event of a software failure. As of Junos OS Release 16.1, for devices running Junos OS with upgraded FreeBSD, provided you have saved a rescue configuration on the device, there is an automatic device recovery mode that goes into action should the system fail to activate the current configuration (amnesiac mode).
NOTE: To determine which platforms run Junos OS with upgraded FreeBSD, see Feature Explorer, enter freebsd, and select Junos kernel upgrade to FreeBSD 10+.
You can identify that the device has recovered automatically from amnesiac mode by the following: · The syslog UI_DEVICE_IN_RECOVERY_MODE is generated, which indicates that there was a
problem in the normal boot time commit and that Junos OS has activated the rescue configuration as the device's configuration. · The CLI displays the banner Device is running in Recovery Mode in both operational and configuration modes. This topic covers the following procedures:
Saving a Rescue Configuration
To save a current device configuration as a rescue configuration file: 1. Edit the configuration file on the device to reflect the base configuration you wish to use. 2. In the CLI operational mode, save this edited base configuration as the rescue configuration file:
user@host> request system configuration rescue save
The rescue configuration file is automatically saved under /config directory as rescue.conf.gz.
Validating the Rescue Configuration
You can verify that the syntax of a configuration file is correct and check for commit check errors by using the test configuration filename command. To verify if a rescue configuration file is correct:

36

· Issue the test configuration filename command from the CLI operational mode.

user@host> test configuration /config/rescue.conf.gz configuration check succeeds
If the configuration contains any syntax or commit check errors, a message is displayed to indicate the line number and column number in which the error was found. This command only accepts text files.
Copying the Configuration to a Remote Server
This task is optional but recommended. To copy the rescue configuration to a remote server: 1. Start the device shell.

user@host> start shell 2. Go to the /config directory and list the rescue configuration file..

% cd /config % ls -lrt rescue.conf.gz -rw-r----- 1 root

wheel

1483 Dec 14 10:50 rescue.conf.gz

3. FTP the configuration file to the remote host.

% ftp host2 Name: username Password: password User user logged in. ftp> cd /var/tmp ftp> lcd /config ftp> bin ftp> put rescue.conf.gz local: rescue.conf.gz remote: rescue.conf.gz
Transfer complete. ftp> bye Goodbye.

37
Rolling Back to Troubleshoot the Failed Configuration Your rescue configuration is probably not exactly the configuration you want or need on your system. Therefore, you will want to examine the failures that occurred when you tried to activate the current configuration and make corrective actions. To correct the failed configuration: 1. Log in to the device through the management IP (or the console if permitted). 2. Load the failed configuration.
user@host# rollback 1
If you are doing this step right after the recovery mode, rollback 1 will be the configuration that cause the amnesiac mode. 3. Make corrections to the configuration. 4. Do a commit check.
user@host# commit check 5. If there are other corrections to make, make them. 6. Commit the configuration.
Rolling Back to the Rescue Configuration Not all platforms run Junos OS with updated FreeBSD. Those that do not or are releases earlier than Junos OS Release 16.1, do not have the automatic recovery mode. You will need to rollback to rescue configuration manually to bring the device back to normal running mode. To roll back to the rescue configuration: 1. Log in to the device through the console. 2. Issue the rollback rescue command from the configuration mode of the CLI.
user@host# rollback rescue
load complete

38
3. Commit the configuration.
user@host# commit 4. Fix the failed configuration. See "Rolling Back to Troubleshoot the Failed Configuration". Deleting an Existing Rescue Configuration To delete an existing rescue configuration: · Issue the request system configuration rescue delete command:
user@host> request system configuration rescue delete
Reverting to the Rescue Configuration
If someone inadvertently commits a configuration that denies management access to a device and the console port is not accessible, you can overwrite the invalid configuration and replace it with the rescue configuration. The rescue configuration is a previously committed, valid configuration. To revert the switch to the rescue configuration: 1. Enter the load override command.
[edit] user@host# load override filename 2. Commit your changes.
[edit] user@host# commit filename

39
Copy Backup Configurations and Restoring a Saved Configurations
IN THIS SECTION Copy Backup Configurations to the Router | 39 Restoring a Saved Configuration | 39

Copy Backup Configurations to the Router
To copy backup configurations to the router, follow these steps:
1. To copy the existing configuration and any backup configurations back onto the router, use the file copy command. Place the files in the /var/tmp directory.

user@host> file copy var/tmp/filename 2. Load and activate the desired configuration:

user@host>

configure

[edit] user@host# load merge/config/filename or

filename

[edit]

user@host# commit

Restoring a Saved Configuration

load replace/config/

IN THIS SECTION Copy Saved Files to the Router | 40 Loading and Committing the Configuration File | 40

To restore a saved configuration, perform the following tasks:

40
Copy Saved Files to the Router
To copy the saved configuration to the router: 1. Log in to the console as root. There is no password.
Escape character is '^]'. [Enter] router (ttyd0)
login: root Password: [Enter]
Initially, access to the router is limited to the console port after a recovery installation. Access through the management ports and interfaces is set in the configuration. For information about accessing the router through the console port, see the administration guide for your particular router. 2. Start the CLI:
# cli
3. Copy the configuration file on the remote server to the router's /var/tmp directory:
root@host> ftp remote-server user: username password: password ftp> bin Type set to I. ftp> get /path/file ftp> bye Goodbye.
Loading and Committing the Configuration File
Once the saved configuration file is copied to the router, you load and commit the file: 1. Start the CLI configuration mode.
user@host> configure Entering configuration mode

41
[edit] user@host#
2. Load the file into the current configuration. You should override the existing file.
user@host# load override /var/tmp/filename load complete
3. Commit the file.
user@host# commit commit complete
4. Exit the CLI configuration mode.
user@host# exit user@host>
5. Back up Junos OS. After you have installed the software on the router, committed the configuration, and are satisfied that the new configuration is successfully running, issue the request system snapshot command to back up the new software to the /altconfig file system. If you do not issue the request system snapshot command, the configuration on the alternate boot drive will be out of sync with the configuration on the primary boot drive. The request system snapshot command causes the root file system to be backed up to /altroot, and / config to be backed up to /altconfig. The root and /config file systems are on the router's CompactFlash card, and the /altroot and /altconfig file systems are on the router's hard disk or solidstate drive (SSD).

42
Reverting to the Default Factory Configuration by Using the request system zeroize Command
The request system zeroize command is a standard Junos OS operational mode command that removes all configuration information and resets all key values. The operation unlinks all user-created data files, including customized configuration and log files, from their directories. The device then reboots and reverts to the factory-default configuration. To completely erase user-created data so that it is unrecoverable, use the request system zeroize media command.
CAUTION: Before issuing request system zeroize, use the request system snapshot command to back up the files currently used to run the device to a secondary device.
To revert to the factory-default configuration by using the request system zeroize command: 1.
user@host> request system zeroize warning: System will be rebooted and may not boot without configuration Erase all data, including configuration and log files? [yes,no] (yes) 2. Type yes to remove configuration and log files and revert to the factory default configuration. 3. Complete the initial configuration of the device.
SEE ALSO request system zeroize | 781
Recovery of Junos OS
IN THIS SECTION Recovering from a Failed Software Installation | 43 Recovering Junos OS on a Device Running Junos OS with Upgraded FreeBSD | 45

43
In case of failed software installation or a failure after installing Junos OS, such as the CLI not working, you can recover the failed software. You can recover the software by installing Junos OS and remove the existing Junos OS image to install a new image.
Recovering from a Failed Software Installation
IN THIS SECTION Problem | 43 Solution | 43
Problem
Description If the Junos OS appears to have been installed but the CLI does not work, or if the device has no software installed, you can use this recovery installation procedure to install the Junos OS.
Solution
If a Junos OS image already exists on the switch, you can either install the new Junos OS package in a separate partition, in which case both Junos OS images remain on the switch, or you can remove the existing Junos OS image before you start the new installation process.
NOTE: QFX5100, QFX5200, EX4600, QFX10000, and OCX Series switches do not have a separate partition to reinstall a Junos OS image. A recovery image is created automatically on these switches. If a previously-running switch is powered on and unable to boot using a Junos OS image, you can boot the switch using the recovery Junos OS image by selecting an option in the "Select a recovery image" menu. We suggest creating a system snapshot on your switch onto the external USB flash drive, and using the snapshot for recovery purposes. The system snapshot feature takes a "snapshot" of the files currently used to run the device--the complete contents of the /config directories, which include the running Juniper Networks Junos OS, the active configuration, and the rescue

44
configuration, as well as the host OS--and copies all of these files into an external USB flash drive. See Creating a Snapshot and Using It to Boot a QFX3500 and QFX3600 Series Switch or Creating a Snapshot and Using It to Boot a QFX Series Switch. System snapshot is not supported on QFX5200 and QFX10000 switches.
To perform a recovery installation: 1. Power on the switch. The loader script starts. 2. After the message Loading /boot/defaults/loader.conf appears, you are prompted with the following
message: Hit [Enter] to boot immediately, or space bar for command prompt. Press the Spacebar to enter the manual loader. The loader> prompt appears.
NOTE: The loader prompt does not appear on QFX5100, QFX5200, EX4600, QFX10000, and OCX Series switches. On QFX5100, QFX5200, EX4600, QFX10000, and OCX Series switches only, a recovery image is automatically saved if a previously-running switch is powered on and unable to boot using a Junos OS image. The "Select a recovery image" menu appears on the console when one of these switches is booted and unable to load a version of Junos OS. Follow the instructions in the "Select a recovery image" menu to load the recovery version of Junos OS for one of these switches. You can ignore the remainder of this procedure if you are using a QFX5100, QFX5200, EX4600, QFX10000, or OCX Series switch.
3. Enter the following command:
loader> install [­ ­format] [­ ­external] source
where: · format--Enables you to erase the installation media before installing the installation package. If
you do not include this option, the system installs the new Junos OS in a different partition from that of the most recently installed Junos OS. · external--Installs the installation package onto external media (a USB stick, for example).

45
· source--Represents the name and location of the Junos OS package, either on a server on the network or as a file on an external media, as shown in the following two examples: · Network address of the server and the path on the server; for example, tftp://192.0.2.0/junos/ jinstall-qfx-5e-flex-15.1X53-D30.5-domestic-signed.tgz · Junos OS package on a USB device (commonly stored in the root drive as the only file), for example, file://jinstall-qfx-5e-flex-15.1X53-D30.5-domestic-signed.tgz).
The installation now proceeds normally and ends with a login prompt.
SEE ALSO Creating a Snapshot and Using It to Boot a QFX3500 and QFX3600 Series Switch Creating a Snapshot and Using It to Boot a QFX Series Switch
Recovering Junos OS on a Device Running Junos OS with Upgraded FreeBSD
Juniper Networks devices that run Junos OS with upgraded FreeBSD have two separate volumes: · dev/gpt/junos (/junos for short) volume that is used to run Junos OS and to store the configuration
and log files · dev/gpt/oam (/oam for short), an Operations, Administration, and Maintenance (OAM) volume that is
used to store a complete backup of Junos OS and the configuration. In case of damage to the device's software or failure of the /junos volume, you can use the backed up software and configuration stored in the /oam volume to boot the system and restore Junos OS with the recovery configuration. To perform this reboot and restore the configuration, the /oam volume must have all of the information required to provide the system with a running configuration. This information is provided by the recovery snapshot, created using the request system snapshot recovery command.
NOTE: You need console access to perform the following procedure to recover Junos OS.
To recover Junos OS by using the recovery snapshot stored in the /oam volume: 1. Power off the device, such as a router or a switch, by pressing the power button on the front panel. 2. Connect and configure the management device, such as a PC or a laptop, as follows:

46
a. Turn off the power to the management device. b. Plug one end of the Ethernet rollover cable supplied with the device into the RJ-45­to­DB-9
serial port adapter supplied with the device. c. Plug the RJ-45­to­DB-9 serial port adapter into the serial port on the management device. d. Connect the other end of the Ethernet rollover cable to the console port on the device. e. Turn on the power to the management device. f. On the management device, start your asynchronous terminal emulation application (such as
Microsoft Windows Hyperterminal) and select the appropriate communication (COM) port to use (for example, COM1). g. Configure the port settings as follows: · Bits per second: 9600 · Data bits: 8 · Parity: None · Stop bits: 1 · Flow control: None 3. Power on the device by pressing the power button on the front panel. Verify that the POWER LED on the front panel turns green. The terminal emulation screen on your management device displays the boot sequence of the device. 4. Access the Junos Main Menu. · In releases before Junos OS Release 17.3, the Junos Main Menu appears for 3 seconds on startup before automatically booting the /junos volume. Press any key within the 3-second window to stop the automatic boot sequence and display the Junos Main Menu.
NOTE: The Junos Main Menu will appear every time you reboot the router while connected to the console.
· Starting in Junos OS Release 17.3, press Ctrl+c within the 3-second window to stop the automatic boot sequence and display the Junos Main Menu.
Main Menu
1. Boot [J]unos volume

47
2. Boot Junos volume in [S]afe mode
3. [R]eboot
4. [B]oot menu 5. [M]ore options
Choice:
5. At the Choice: prompt in Junos Main Menu, enter B or 4 to choose 4. [B]oot menu :
Boot Menu
1. Boot [P]revious installed Junos packages 2. Boot Junos in [S]ingle user mode 3. Boot from [R]ecovery snapshot
4. Boot from [U]SB
5. Boot to [O]AM shell
6. Snapshot [B]oot menu
7. [M]ain menu
Choice:
6. At the Choice: prompt in Boot Menu, enter R or 3 to choose the 3. Boot from [R]ecovery snapshot option. The device reboots into recovery mode. The following sample output shows the messages displayed on the terminal when you recover Junos OS on an EX2300 switch.
Booting from recovery snapshot ... /boot/junos/boot/os-kernel/kernel data=0xe8c000 syms=[0x4+0x6b020+0x4+0x72cfe] /boot/junos/boot/os-kernel/ex2300-48mp.dtb size=0x18b8 /boot/junos/boot/os-kernel/ex2300.dtb size=0x1e67 /boot/junos/boot/junos-modules/fips_core.ko text=0x13bc data=0x275+0x7 syms=[0x4+0x7a0+0x4+0x518] loading required module 'netstack' /boot/junos/boot/netstack/netstack.ko text=0x910a3c data=0x3ae2f+0x10dded syms=[0x4+0xf0570+0x4+0xdc394] loading required module 'crypto'

48
[...Output truncated...]
/var/pdb/profile_db initialized
Profile database initialized realpath: /dev/dumpdev: No such file or directory /etc/rc: WARNING: Dump device does not exist. Savecore not run. Prefetching /usr/sbin/rpd ... Prefetching /usr/sbin/lacpd ... Prefetching /usr/sbin/chassisd ... mkdir: /packages/sets/active: Read-only file system Starting jlaunchhelperd. sysctl: unknown oid 'kern.rtc_retries' Starting cron.
Fri Jun 22 01:25:20 PDT 2018
FreeBSD/arm (device-name) (ttyu0)
login:
7. Log in to the device and verify that the software is properly restored.
[...Output truncated...] login: root
--- JUNOS 18.1-20180125.0 built 2018-01-25 20:34:55 UTC
root@:RE:0%

49
How to Recover Junos OS with Upgraded FreeBSD
IN THIS SECTION Ways to Recover Junos OS with Upgraded FreeBSD Without the Use of the CLI | 49 How to Access the Junos Main Menu, Boot Menu, and Options Menu | 53
Ways to Recover Junos OS with Upgraded FreeBSD Without the Use of the CLI
IN THIS SECTION Boot from the /junos Volume | 50 Boot from Safe Mode | 50 Boot from a Previously Installed Release of Junos OS with Upgraded FreeBSD | 50 Boot into Single-User Mode | 51 Boot from a Recovery Snapshot | 51 Boot from a USB Device | 52 Boot to the OAM Shell | 52 CLI Recovery Mode | 52 Check File System | 52 Enable/Disable Verbose Boot | 52 Boot Prompt | 52
If a device running Junos OS with upgraded FreeBSD has a damaged operating system or configuration that prevents the system from booting normally, or you need to recover the root password, the CLI is unavailable to you. But you can access and use the Junos Main Menu and Boot Menu. These menus have options such as booting from a USB device or a previously installed version of Junos OS, or using CLI Recovery mode to change you root password. To see how to access these menus, see "How to Access the Junos Main Menu, Boot Menu, and Options Menu".

50
Boot from the /junos Volume
Juniper Networks devices that run Junos OS with upgraded FreeBSD have two separate volumes:
· dev/gpt/junos (/junos for short) volume that is used to run Junos OS and to store the configuration and log files
· dev/gpt/oam (/oam for short), an Operations, Administration, and Maintenance (OAM) volume that is used to store a complete backup of Junos OS and the configuration.
If a device running Junos OS with upgraded FreeBSD has a damaged operating system or configuration, preventing the system from booting normally, you can still boot from the /junos volume without using the CLI command request system reboot. Access the Junos Main Menu. Booting the /junos volume is the first option on the Junos Main Menu.
Boot from Safe Mode
Safe mode is a diagnostic mode of a computer's operating system that has reduced functionality, making the task of isolating problems easier since many non-core components are disabled. In Junos OS with upgraded FreeBSD, safe mode boots the entire Junos OS and FreeBSD but with a few kernel features disabled.
One other difference between normal mode and safe mode is that for EX3400 devices, symmetric multiprocessing (SMP) in normal mode uses a dual core, whereas in safe mode, it uses a single core.
An installation that has a major problem (such as disk corruption or the installation of poorly configured software) that prevents the operating system from booting into its normal operating mode may boot in safe mode and allow you to diagnose the problem.
Booting from Safe Mode is the second option on the Junos Main Menu.
Boot from a Previously Installed Release of Junos OS with Upgraded FreeBSD
With devices running Junos OS with upgraded Freebsd, you can boot from a previous release of the OS, provided there was a previous image on the device and it is still there. Previous image files can be found in the /packages/sets/previous directory. Some platforms do not keep an older image due to storage space limitations (for example, EX2300 and EX3400 do not have a /packages/sets/previous directory).
The following is sample output from an EX9200 switch, showing the previous image:
root@:/ # ls -al /packages/sets/previous/ total 20 drwxr-xr-x 4 root wheel 1536 Mar 30 15:45 . drwxrwxrwx 4 root wheel 512 Mar 30 18:47 ..

51
drwxr-xr-x 2 root wheel 512 Mar 30 15:45 boot lrwxr-xr-x 1 root wheel 66 Mar 30 15:44 jail-runtime -> /packages/db/jailruntime-x86-32-20171012.356211_builder_stable_10 lrwxr-xr-x 1 root wheel 62 Mar 30 15:44 jdocs -> /packages/db/jdocsx86-32-20171121.225603_builder_junos_161_r6 lrwxr-xr-x 1 root wheel 63 Mar 30 15:44 jpfe-X -> /packages/db/jpfe-Xx86-32-20171121.225603_builder_junos_161_r6
...
To see if there are previous packages on the device, do one of the following: · From a UNIX shell, issue the ls /packages/sets/previous command. · From the CLI operational mode, use the file list /packages/sets/previous command. Booting from a previously installed release of Junos OS with upgraded FreeBSD is the first option on the Boot Menu. System boots the previous Junos OS with upgraded FreeBSD image. If there is no previous image, system boots from the currently installed image.
Boot into Single-User Mode
Single-user mode is a mode in which a multi-user computer operating system boots into a single superuser. It is mainly used for maintenance of multi-user environments. For devices running Junos OS with upgraded FreeBSD, single-user mode puts you in a shell with a prompt. There is limited support and password recovery is not possible using this option. But you can do few file operations. Booting into single-user mode is the second option on the Boot Menu..
Boot from a Recovery Snapshot
A recovery snapshot for devices running Junos OS with upgraded FreeBSD is taken with the request system snapshot recovery command. Recovery snapshots are full copies of the packages and configuration taken at the time the snapshot command is issued. Booting from a recovery snapshot is the third option on the Boot Menu.

52
Boot from a USB Device
If you want to boot from a USB device, you must connect the USB device to the router or switch. Then select the fourth option on the Boot Menu. If no USB device is connected, you will see a message No USB media found.
Boot to the OAM Shell
The Boot to the OAM Shell option is similar to the single-user mode except that you are put into the oam shell or volume. The compact flash drive is the /oam volume and stores recovery snapshot backup information. In case of failure of the /junos volume, the /oam volume can be used to boot the system. Booting to the oam shell is the fifth option on the Boot Menu.
CLI Recovery Mode
If you choose the CLI Recovery Mode option, you end up at a root> prompt. Enter configure at the prompt to enter the configuration CLI mode. From there you can change the root password to recover your access to the device (see Recovering the Root Password on Routers). The CLI Recovery Mode is the second option on the Options Menu.
Check File System
The check file system option lets you make sure there are no issues or corrupted files. The system boots from the OAM volume to perform disk checks. This is the third option on the Options Menu.
Enable/Disable Verbose Boot
Choosing the fourth option on the Options Menu either enables verbose boot, which lets you see the whole boot scroll by, or disables verbose boot.
Boot Prompt
The Boot Prompt option displays an OK prompt from which you can type one of the following commands: · menu--Takes you back to the Junos Main Menu. · boot-junos--Boots the device to the current version of Junos OS. · reboot--Reboots the system.

53
You can also type ? at the OK prompt to see several other available commands. The boot prompt option is the fifth option on the Options Menu.
How to Access the Junos Main Menu, Boot Menu, and Options Menu
IN THIS SECTION How to Access the Junos Main Menu | 53 How to Access the Boot Menu | 55 How to Access the Options Menu | 56
If a device running Junos OS with upgraded FreeBSD has a damaged operating system or configuration, preventing the system from booting normally, you can still boot using an option on the Junos Main Menu, Boot Menu, or Options Menu. The following procedures show you how to access these menus.
How to Access the Junos Main Menu
You access the Junos Main Menu by interrupting the reboot of a device.
NOTE: You need console access (either direct access to console or via a console server) to perform the following procedure.
You can either perform the entire procedure or power-cycle the device and start the procedure from Step 4. (You can also perform these reboots by rebooting the device via the CLI if that is available.) To boot a device running Junos OS with upgraded FreeBSD without using the CLI: 1. Power off the device, such as a router or a switch, by pressing the power button on the front panel. 2. Connect and configure the management device, such as a PC or a laptop, as follows:
a. Turn off the power to the management device. b. Plug one end of the Ethernet rollover cable supplied with the device into the RJ-45­to­DB-9
serial port adapter supplied with the device. c. Plug the RJ-45­to­DB-9 serial port adapter into the serial port on the management device. d. Connect the other end of the Ethernet rollover cable to the console port on the device.

54
e. Turn on the power to the management device. f. On the management device, start your asynchronous terminal emulation application (such as
Microsoft Windows Hyperterminal) and select the appropriate communication (COM) port to use (for example, COM1). g. Configure the port settings as follows: · Bits per second: 9600 · Data bits: 8 · Parity: None · Stop bits: 1 · Flow control: None 3. Power on the device by pressing the power button on the front panel. Verify that the POWER LED on the front panel turns green. The terminal emulation screen on your management device displays the boot sequence of the device. 4. Access the Junos Main Menu. Do one of the following · Prior to Junos OS Release 17.3, the Junos Main Menu appears for three seconds on startup before automatically booting from the /junos volume. Press any key within the three-second interval to stop the automatic boot sequence and display the Junos Main Menu. · Starting in Junos OS Release 17.3, press Ctrl+c at the following part in the reboot:
FreeBSD/x86 bootstrap loader, Revision 1.1 (builder@feyrith.juniper.net, Sun Feb 4 13:06:24 PST 2018) / Autoboot in 1 seconds... (press Ctrl-C to interrupt)
The Junos Main Menu is displayed:
Main Menu
1. Boot [J]unos volume 2. Boot Junos volume in [S]afe mode
3. [R]eboot

55
4. [B]oot menu 5. [M]ore options Choice: 5. At the Choice: prompt in the Junos Main Menu, enter the number representing the option you want to use. Alternatively, you can enter the letter in square brackets to choose an option.
How to Access the Boot Menu
The Boot Menu is one of two menus you can access from the Junos Main Menu.
NOTE: You need console access to perform the following procedure.
You must first access the Junos Main Menu. See "How to Access the Junos Main Menu". To access the Boot Menu: 1. At the Choice: prompt in the Junos Main Menu, enter 4 or B to choose 4. [B]oot menu.
The Boot Menu is displayed.
Boot Menu 1. Boot [P]revious installed Junos packages 2. Boot Junos in [S]ingle user mode 3. Boot from [R]ecovery snapshot 4. Boot from [U]SB 5. Boot to [O]AM shell 6. Snapshot [B]oot menu 7. [M]ain menu Choice: 2. At the Choice: prompt in the Boot Menu, enter the number representing the option you want to use. Alternatively, you can enter the letter in square brackets to choose an option.

56
How to Access the Options Menu
The Options Menu is one of two menus you can access from the Junos Main Menu.
NOTE: You need console access to perform the following procedure.
You must first access the Junos Main Menu. See "How to Access the Junos Main Menu". To access the Options Menu: 1. At the Choice: prompt in the Junos Main Menu, enter 5 or M to choose 5. [M]ore options.
The Options Menu is displayed.
Options Menu 4 1. Recover [J]unos volume 2. Recovery mode - [C]LI 3. Check [F]ile system 4. Enable [V]erbose boot 5. [B]oot prompt 6. [M]ain menu Choice: 2. At the Choice: prompt in the Options Menu, enter the number representing the option you want to use. Alternatively, you can enter the letter in square brackets to choose an option.

57
Autorecovery of Configuration, Licenses, and Disk Information on SRX Series Devices
IN THIS SECTION Overview | 57 How Autorecovery Works | 58 How to Use Autorecovery | 58 Data That Is Backed Up in an Autorecovery | 58 Troubleshooting Alarms | 59 Considerations | 60
Autorecovery helps to detect and recover information on disk partitioning, configuration, and licenses in the event of disk becomes corrupted
Overview
The autorecovery feature is supported on dual-partitioned SRX Series devices. With this feature, information on disk partitioning, configuration, and licenses is recovered automatically in the event it becomes corrupted. Autorecovery provides the following functions: · Detect corruption in disk partitioning during system bootup and attempt to recover partitions
automatically · Detect corruption in the Junos OS rescue configuration during system bootup and attempt to
recover the rescue configuration automatically · Detect corruption in Junos OS licenses during system bootup and attempt to recover licenses
automatically

58
How Autorecovery Works
The feature works in the following ways: · The feature provides the request system autorecovery state save command, which backs up
important data such as disk partitioning information, licenses, and Junos OS rescue configuration. · Once the backup copies are saved, they are used to check the integrity of the working copies of the
data on every bootup. · The working copies are automatically recovered if any corruption is detected.
How to Use Autorecovery
You use autorecovery in the following ways: · Prepare the router for deployment with the necessary licenses and configuration. · After you finalize the state, execute the request system autorecovery state save command to back
up the state. · After you save the state, integrity check and recovery actions (if any) occur automatically on every
bootup. · If subsequent maintenance activities change the state of the router by adding licenses or updating
the configuration, you need to execute the request system autorecovery state save command again to update the saved state. · Execute the show system autorecovery state command any time to view the status of the saved information and the integrity check status of each saved item. · Execute the request system autorecovery state clear command to delete all backed up data and disable autorecovery, if required.
Data That Is Backed Up in an Autorecovery
The following data is backed up during the autorecovery process: · Rescue configuration (regenerated from the current configuration) · License keys

59
· BSD lables (disk-partitioning information) Data is backed up only when you execute the request system autorecovery state save command. Diskpartitioning information is backed up automatically from factory defaults (for new systems), on installation from the boot loader, and on snapshot creation.

Troubleshooting Alarms

Table 1 on page 59 lists types of autorecovery alarms, descriptions, and required actions. Table 1: Autorecovery Alarms

Alarm

Alarm Type

Description

Action Required

Autorecovery information needs to be saved

Minor

This alarm indicates:
· Unsaved data needs to be saved, or saved data contains problems and another save is required.

· Ensure that the system has all required licenses and configuration.
· Execute the request system autorecovery state save command.

Autorecovery has recovered corrupted information

Minor

This alarm indicates:
· Boot time integrity check failed for certain items; however, the items have been recovered successfully.

· No action is required.
· Alarm is cleared on next bootup.

Autorecovery was unable to recover data completely

Major

This alarm indicates:
· Boot time integrity check failed for certain items, which could not be recovered successfully.

· The system might be experiencing a fatal malfunction.

60
Considerations
· Devices must have dual-root partitioning for autorecovery to work. · The request system configuration rescue save command regenerates the rescue configuration from
the current Junos OS configuration and then saves it. Therefore, executing the save command overwrites any existing rescue configuration. · In general, the saved contents of the rescue configuration are not updated automatically. If you add licenses, you must execute the request system autorecovery state save command again.
NOTE: The rescue configuration is backed up. If /config is corrupted, the system boots from the rescue configuration.
RELATED DOCUMENTATION Creating a Snapshot and Using It to Boot an SRX Series device | 15 Example: Installing Junos OS Upgrade Packages on SRX Series Devices | 236 Reverting the Junos OS Software Image Back to the Previous Version | 245

3 CHAPTER
Installing, Upgrading, and Downgrading Software
Software Installation and Upgrade Overview | 63 Preparing for Software Installation and Upgrade | 81 Managing YANG Packages and Configurations During a Software Upgrade or Downgrade | 118 Installing Software on Routing Devices | 121 Installing Software on EX Series Switches | 132 Installing Software on QFX Series Devices | 151 How To Install Third-Party Software on Devices Running Junos OS Evolved | 189 Personality Upgrade Process | 191 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices | 214 Upgrade the NFX250 Software to NFX250 NextGen Software | 230 Installing Software on SRX Series Devices | 233 Upgrading and Downgrading to Junos with Upgraded FreeBSD | 264 Installing Software on ACX Series Routers | 277 Installing and Recovering Software Using the Open Network Install Environment (ONIE) | 279 Overview of Upgrading to 64-bit Junos OS | 294 Veriexec Overview | 299

63
Software Installation and Upgrade Overview
IN THIS SECTION Software Installation and Upgrade Overview | 63 Junos OS and Junos OS Evolved Installation Package Names | 69 Boot Sequence on Devices with Routing Engines | 77
A Juniper Networks device is delivered with the Juniper Networks operating system (Junos OS or Junos OS Evolved) preinstalled. As new features and software fixes become available, you must upgrade your software to use them. Before the upgrade, back up the configuration files.
Software Installation and Upgrade Overview
IN THIS SECTION Types of Junos OS Installation | 64 Backing Up the Current System's Files | 65 Determining Software Installation Package | 66 Connecting to the Console | 66 Validating the Installation Package with the Current Configuration | 67 Dual-Root and Single-Root Partitioning (SRX Series Only) | 68
A Juniper Networks device is delivered with the Juniper Networks operating system (Junos OS or Junos OS Evolved) preinstalled. When you power on the device, it starts (boots) using the installed software. As new features and software fixes become available, you must upgrade your software to use them. You upgrade (or downgrade) the version of the operating system on a device by copying a software installation package to your device or other system on your local network and then using the CLI to install the new software on the device. You then reboot the device, which boots from the newly installed software.

64
Before installing software, back up the system, select the software installation package you require, and download it from the Juniper Networks downloads page. If you encounter any difficulties during software installation, you can use the recovery installation procedure to install the operating system on the device. After a successful upgrade, back up the new existing configuration to a secondary device.
NOTE: Before installing software on a device that has one or more custom YANG data models added to it, back up and remove the configuration data corresponding to the custom YANG data models from the active configuration. For more information see Managing YANG Packages and Configurations During a Software Upgrade or Downgrade.
To understand more about Junos OS Software Licensing, see the Juniper Licensing Guide. Please refer to the product Data Sheets accessible from Products & Services for details, or contact your Juniper Account Team or Juniper Partner.
· For features on EX Series Switches that require license, see Understanding Software Licenses for EX Series Switches
· For features on M Series Routers that require license, see Software Features That Require Licenses on M Series Routers Only
· For features on M Series, MX Series, and T Series Routers that require license, see Software Features That Require Licenses on M Series, MX Series, and T Series Routers
· For features on MX Series Routers that require license, see Software Features That Require Licenses on MX Series Routers Only
· For features on QFX Series Switches that require license, see Software Features That Require Licenses on the QFX Series.
· For features on SRX Series devices that require license, see Software Feature Licenses for SRX Series Devices.
The following subsections introduce the overall considerations in installing the software:
Types of Junos OS Installation
The three types of installations used to upgrade or downgrade your device are standard installation, category change, and recovery. The standard installation is the standard method of upgrading and downgrading the software. Use a category change installation when you are moving from one software category to another; for example, if you are changing the device from using the standard Junos OS to the Junos-FIPS category. Perform a recovery installation when the software on the device is damaged or otherwise unable to accommodate a software upgrade or downgrade.

65

Standard Installation Category Change Installation

A standard installation is the typical method used to upgrade or downgrade software on the server. This method uses the installation package that matches the installation package already installed on the system. For information on the different installation packages available, see Junos OS and Junos OS Evolved Installation Packages Prefixes.
The category change installation process is used to move from one category of Junos OS to another on the same router; for example, moving from a Junos OS standard installation on a router to a Junos-FIPS installation. When moving from one installation category to another, you need to be aware of the restrictions regarding this change.

NOTE: Juniper Networks does not support using the request system software rollback command to restore a different installation category on the device. When installing a different Junos OS category on a device, once the installation is complete, you should execute a request system snapshot command to delete the backup installation from the system.

Recovery Installation

A recovery installation is performed to repair a device with damaged software or a condition that prevents the upgrade, downgrade, or change in installation category of the software.

Backing Up the Current System's Files
Creating a backup of the current system on your device has the following advantages:
· The device can boot from a backup and come back online in case of failure or corruption of the primary boot device in the event of power failure during an upgrade.
· Your active configuration files and log files are retained.
· The device can recover from a known, stable environment in case of an unsuccessful upgrade.
During a successful upgrade, the upgrade package completely reinstalls the existing operating system. It retains only the juniper.conf and SSH files. Other information is removed. Therefore, you should back up your existing configuration in case you need to return to it after running the installation program.
You can create copies of the software running on a device using the system snapshot feature. The system snapshot feature takes a "snapshot" of the files currently used to run the device--the complete contents of the /config and /var directories, which include the running software, the active configuration, and the rescue configuration--and copies all of these files into an alternate (internal, meaning internal flash, or an external, meaning USB flash) memory source. You can then use this snapshot to boot the device at the next boot up or as a backup boot option. When the backup is completed, the existing and backup software installations are identical.

66
NOTE: Snapshots taken with the request system snapshot command in a Junos OS with upgraded FreeBSD system are not the same as those snapshots taken with the request system snapshot command in a Junos OS (as in legacy Junos OS) system. To back up your Junos OS with upgraded FreeBSD system devices, use the request system snapshot recovery command.
When the correct snapshot command is issued, the /root file system is backed up to /altroot, and / config is backed up to /altconfig. The /root and /config file systems are on the devices's CompactFlash card, and the /altroot and /altconfig file systems are on the devices's hard disk or or solid-state drive (SSD).
Determining Software Installation Package
All software releases are delivered in signed packages that contain digital signatures to ensure official Juniper Networks software. To see which software packages are currently running on the device and to get information about these packages, use the show version operational mode command at the top level of the command-line interface (CLI).
NOTE: The show version command does not show the software edition installed, only the release number of the software.
You can either download software to the /var/tmp directory of your device, or install it directly from the downloads page. For more information about signed software packages, see the Junos OS and Junos OS Evolved Installation Package Names.
Connecting to the Console
We recommend that you upgrade all individual software packages using an out-of-band connection from the console or management Ethernet interface, because in-band connections can be lost during the upgrade process. Console ports allow root access to the Junos operating system (Junos OS) devices through a terminal or laptop interface, regardless of the state of the Junos OS device, unless it is completely powered off. By connecting to the console port, you can access the root level of the Junos OS device without using the network to which the device might or might not be connected. This creates a secondary path to the Junos OS device without relying on the network. Using the terminal interface provides a technician sitting in a Network Operations Center a long distance away the ability to restore a Junos OS device or perform an initialization configuration securely, using a

67 modem, even if the primary network has failed. Without a connection to the console port, a technician would have to visit the site to perform repairs or initialization. A remote connection to the Junos OS device through a modem requires the cable and connector (provided in the device accessory box), plus a DB-9 to DB-25 (or similar) adapter for your modem, which you must purchase separately. For more information about connecting to the console port, see the administration guide for your particular device. To configure the device initially, you must connect a terminal or laptop computer to the device through the console port, as shown in Figure 1 on page 67. Figure 1: Connecting to the Console Port on a Juniper Networks Device
Validating the Installation Package with the Current Configuration
When you upgrade or downgrade software, we recommend that you include the validate option with the request system software add command to check that the candidate software is compatible with the current configuration. By default, when you add a package with a different release number, the validation check is done automatically. Direct validation of the running configuration does not work for upgrading to Junos OS with upgraded FreeBSD from Junos OS based on older versions of the FreeBSD kernel. Therefore, when upgrading or

68
downgrading between Junos OS and Junos OS with upgraded FreeBSD, you might have to validate on a different host. If you do not want to validate when upgrading, you must specify the no-validate option.
Dual-Root and Single-Root Partitioning (SRX Series Only)
SRX Series devices that ship from the factory with Junos OS Release 10.0 or later are formatted with the dual-root partitioning scheme.
NOTE: Junos OS Release 12.1X45 and later do not support single-root partitioning.
NOTE: SRX100, SRX110, SRX210, SRX220, and SRX240 devices with 2 GB RAM cannot be upgraded to any Junos OS 12.1X46 Release after 12.1X46-D65. Attempting to upgrade to this release on devices with 2 GB RAM will trigger the following error: ERROR: Unsupported platform for 12.1X46 releases after 12.1X46-D65
Existing SRX Series devices that are running Junos OS Release 9.6 or earlier use the single-root partitioning scheme. While upgrading these devices to Junos OS Release 10.0 or later, you can choose to format the storage media with dual-root partitioning (strongly recommended) or retain the existing single-root partitioning. Certain Junos OS upgrade methods format the internal media before installation, whereas other methods do not. To install Junos OS Release 10.0 or later with the dual-root partitioning scheme, you must use an upgrade method that formats the internal media before installation.
NOTE: If you are upgrading to Junos OS Release 10.0 without transitioning to dual-root partitioning, use the conventional CLI and J-Web user interface installation methods.
These upgrade methods format the internal media before installation: · Installation from the boot loader using a TFTP server · Installation from the boot loader using a USB storage device · Installation from the CLI using the partition option (available in Junos OS Release 10.0) · Installation using the J-Web user interface These upgrade methods retain the existing partitioning scheme:

69
· Installation using the CLI · Installation using the J-Web user interface
CAUTION: Upgrade methods that format the internal media before installation wipe out the existing contents of the media. Only the current configuration is preserved. Any important data must be backed up before starting the process.
NOTE: Once the media has been formatted with the dual-root partitioning scheme, you can use conventional CLI or J-Web user interface installation methods, which retain the existing partitioning and contents of the media, for subsequent upgrades.
Junos OS and Junos OS Evolved Installation Package Names
IN THIS SECTION Junos OS and Junos OS Evolved Installation Packages Prefixes | 70 Junos OS and Junos OS Evolved Release Numbers | 75 Junos OS and Junos OS Evolved Editions | 76
The installation package is used to upgrade or downgrade from one release to another. When installed, the installation package completely reinstalls the software, rebuilds the Junos OS file system, and can erase system logs and other auxiliary information from the previous installation. The installation package does, however, retain the configuration files from the previous installation. Junos OS and Junos OS Evolved installation packages have the following general pattern: 1. prefix-release-edition-signed.extension For enhanced automation variants of Junos OS, the installation package looks like this: 1. prefix-flex-release-edition-signed.extension The signed part of the filename indicates that the software is delivered in signed packages that contain digital signatures, Secure Hash Algorithm (SHA-1), and Message Digest 5 (MD5) checksums. A package

70
is installed only if the checksum within it matches the hash recorded in its corresponding file. Which checksum is used depends on the software version:
· Digital signatures are used when you upgrade or downgrade between Junos OS Release 7.0 and a later version.
· The SHA-1 checksum is used when you upgrade or downgrade between Junos OS Release 6.4 and a later version.
· The MD5 checksum is used when you upgrade or downgrade between Junos OS Release 6.3 or earlier and a later version.
Starting in 2015, the word signed appears less frequently after the edition in the filename. But you might still see it in software installation packages. Whether signed appears or not, all Junos OS images from Junos OS Release 15.1 on are signed for validation. All Junos OS Evolved images are signed for validation.
Extensions are tgz, gz, img, iso, etc.
For more detail on the makeup of the installation package filename, see the following sections:
Junos OS and Junos OS Evolved Installation Packages Prefixes
The first part of the installation package filename is a combination of a standard prefix and product designation. Table 1 lists a variety of Junos OS package name prefixes.
Starting in Junos OS Release 15.1, certain hardware platforms run a Junos OS based on an upgraded FreeBSD kernel (hereafter called Junos OS with upgraded FreeBSD). Table 1 also indicates the prefixes used for the different platforms running Junos OS with upgraded FreesBSD.
SRX Series packages use the following naming convention for package prefixes:
1. junos-product
Table 1 lists several examples of installation package prefixes for the SRX Series.
Table 1 does not list packages you do not use with the request system software add command. For information on packages you load onto a USB drive to install, see Chapter 10 of the Software Installation and Upgrade Guide.

71

Table 2: Installation Package Prefixes

Installation Package Prefix Description

jinstall*

Junos OS for M Series, MX Series, T Series, TX Matrix, and TX Matrix Plus routers.

jinstall64*

64-bit Junos OS for the JCS1200 Route Reflector, TX Matrix Plus routers with 3D SIBs, and PTX Series Packet Transport Routers.

jinstall-ex*

Junos OS for the EX Series Ethernet Switch portfolio.

jinstall-host-acx5k*

Junos OS for the ACX5000 Series routers.

jinstall-host-nfx-2*

Junos OS with upgraded FreeBSD for NFX2xx platforms that are Linux based; this prefix indicates the image includes the host and Junos OS.
For details and specific examples of package names for Junos OS with upgraded FreeBSD, see Changes in Package Names for Junos OS with Upgraded FreeBSD.

jinstall-host-qfx*

Junos OS with upgraded FreeBSD for QFX platforms that are Linux based; this prefix indicates the image includes the host and Junos OS. For example, jinstall-host-qfx-5-release.tgz is the package name for Junos OS on the QFX5100.
For details and specific examples of package names for Junos OS with upgraded FreeBSD, see Changes in Package Names for Junos OS with Upgraded FreeBSD.

jinstall-ocx-flex*

OCX Series switches.

jinstall-ppc*

Junos OS for the ACX Series, MX5, MX10, MX40, MX80, and MX104 routers.

72

Table 2: Installation Package Prefixes (Continued) Installation Package Prefix Description

junos-arm

Junos OS with Upgraded FreeBSD for EX2300 and EX3400 switches.
For details and specific examples of package names for Junos OS with upgraded FreeBSD, see Changes in Package Names for Junos OS with Upgraded FreeBSD.

junos-install*

Junos OS with upgraded FreeBSD for EX Series and MX Series routers that support Junos OS with upgraded FreeBSD.
For specific examples of package names for Junos OS with upgraded FreeBSD, see Changes in Package Names for Junos OS with Upgraded FreeBSD.

73

Table 2: Installation Package Prefixes (Continued) Installation Package Prefix Description

junos-evo-install* or junosevo-install-media*

Junos OS Evolved, introduced as of Junos OS Evolved Release 18.3R1. For Junos OS Evolved, there is a single image for all fixed form (versus chassis) platforms, and a platform image name can also be distinguished as merchant silicon (ms). Starting in Junos OS Evolved 20.3R1, install packages are available in limited editions. See "Junos OS and Junos OS Evolved Editions". Here are some examples:
· junos-evo-install-qfx-ms-fixed-x86-64-version.iso--Single image for all QFX platforms based on merchant silicon. It could be Broadcom family or any other vendor.
· junos-evo-install-ptx-fixed-x86-32-version.iso--All fixed PTX platform variants (that is, PTX10001-36MR, and so on) have a single ISO image.
· junos-evo-install-ptx-fixed-x86-64-version.iso--All fixed PTX platform variants (that is, PTX10003, and so on) have a single ISO image. For PTX orders, this image is installed as factory default.
· junos-evo-install-qfx-fixed-x86-64-version.iso--All fixed QFX platform variants have a single ISO image. For QFX orders, this image is installed as factory default.
· junos-evo-install-ptx-chassis-x86-64-version.iso--One single ISO image for PTX chassis platforms.
· junos-evo-install-qfx-chassis-x86-64-version.iso--One single ISO image for QTX chassis platforms.

junos-evo-profile1-install*

Junos OS Evolved, introduced as of Junos OS Evolved Release 19.1R1. For example, junos-evo-profile1-install-qfx-ms-fixedx86-64-19.1-20190226.5-EVO.iso. Download the Services Profile 1 image to use the lean RPD profile.

74

Table 2: Installation Package Prefixes (Continued) Installation Package Prefix Description

junos-install*

Junos OS with upgraded FreeBSD for EX Series and MX Series routers that support Junos OS with upgraded FreeBSD.
For specific examples of package names for Junos OS with upgraded FreeBSD, see Changes in Package Names for Junos OS with Upgraded FreeBSD.

junos-install-media-pxesrxhe-x86* (USB)
junos-install-media-usbsrxhe-x86* (PXE)
junos-srxhe-x86* (CLI)

Junos OS for SRX4600

junos-srx1k3k*

Junos OS for SRX1400, SRX3400 and SRX3600.

junos-srx5000*

Junos OS for SRX5400, SRX5600, and SRX5800.

junos-srxentedge*

Junos OS for SRX1500.

junos-srxmr*

Junos OS for SRX4100 and SRX4200.

junos-srxsme*

Junos OS for SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M.

junos-vmhost-install*

Junos OS with upgraded FreeBSD on VM Host.

junos-install-media-pxesrxhe-x86* (USB)
junos-install-media-usbsrxhe-x86* (PXE)
junos-srxhe-x86* (CLI)

Junos OS for SRX4600

75
SEE ALSO show version
Junos OS and Junos OS Evolved Release Numbers
NOTE: Junos OS Evolved uses the same release numbering system as Junos OS.
The release number represents a particular revision of the software that runs on a Juniper Networks routing platform, for example, Junos OS Release 14.1,14.2, 15.1, or 17.1. Each release has certain new features that complement the software processes that support Internet routing protocols, control the device's interfaces and the device chassis itself, and allow device system management. On the Juniper Networks Support web page, you download software for a particular release number. In this example, we dissect the format of the software release number to show what it indicates. The generalized format is as follows: Given the format of 1. m.nZb.s The software release number 17.2R1.13, for example, maps to this format as follows: · m is the main release number of the product, for example, 17. · n is the minor release number of the product, for example, 2. · Z is the type of software release, for example, R for FRS or maintenance release.
For types of software releases, see Table 2. · b is the build number of the product, for example, 1, indicating the FRS rather than a maintenance
release.. · s is the spin number of the product, for example, 13.

Table 3: Software Release Types Release Type Description

R

First revenue ship (FRS) or maintenance release software. R1 is FRS. R2 onward are

maintenance releases.

76

Table 3: Software Release Types (Continued) Release Type Description

F

Feature velocity release. Feature velocity releases are only in Junos OS Release 15.1.

B

Beta release software.

I

Internal release software. These are private software releases for verifying fixes.

S

Service release software, which are released to customers to solve a specific problem--

this release will be maintained along with the life span of the underlying release. The

service release number is added after the R number, for example, 14.2R3-S4.4. Here

S4 represents the 4th service release on top of 14.2R3 and is the 4th re-spin.

X

Special (eXception) release software. X releases follow a numbering system that differs

from the standard release numbering.

Starting with Junos OS Release 12.1X44-D10, SRX Series devices follow a special naming convention for Junos OS releases. For more information, refer to the Knowledge Base article KB30092 at https://kb.juniper.net/InfoCenter/index? page=home.

NOTE: Prior to Junos OS Release 11.4, the software release number format for service releases was same as other releases. For example, 10.4S4.2 represented the 4th service release and 2nd re-spin of 10.4.
Junos OS and Junos OS Evolved Editions
Editions show up in the installation package name after the release number string and before signed.
In releases earlier than Junos OS Release 15.1, installation packages came in several major software package categories or editions, such as domestic, worldwide, or Federal Information Processing Standard (FIPS). For those still using packages with names including these terms, here is what they indicate:
· domestic--Junos OS for customers in the United States and Canada and for all other customers with a valid encryption agreement. This edition includes high-encryption capabilities such as IPsec and

77

SSH for data leaving the router or switch. Later images use a null, or empty, edition field for this category.

· limited--Junos OS for all other customers. This edition does not include any high-encryption capabilities for data leaving the router or switch. Sometimes referred to as the Export edition, starting in Junos OS Release 15.1R1, this category is is renamed to the limited edition.

· fips--Junos OS that provides advanced network security for customers who need software tools to configure a network of Juniper Networks routers and switches in a Federal Information Processing Standards (FIPS) 140-2 environment. For more information about Junos-FIPS, see FIPS 140-2 Security Compliance. In later images, FIPS, instead of being a separate edition, is an option you select on installation.

Starting with Junos OS 15.1, a simplified edition scheme was started:

· Junos OS with a null (empty) edition field is the standard image for Junos OS.

· limited--Version has no cryptographic support and is intended for countries in the Eurasian Customs Union (EACU). These countries have import restrictions on software containing data-plane encryption.

For Junos OS Evolved:

· Junos OS Evolved with a null (empty) edition field is the standard image for Junos OS Evolved.

· limited--Starting in Junos OS Evolved 20.3R1, limited packages are available. Limited packages do not have cryptographic support and are intended for countries in the Eurasian Customs Union (EACU). These countries have import restrictions on software containing data-plane encryption. For example, junos-evo-install-ptx-fixed-x86-64-20.3R1-limited.iso.

Release History Table

Release

Description

20.3R1 Evolved Starting in Junos OS Evolved 20.3R1, install packages are available in limited editions.

Boot Sequence on Devices with Routing Engines
IN THIS SECTION Boot Order for Devices | 78

78
Booting from an Alternate Boot Device | 80
Juniper Networks devices start using the installed Junos OS. Bootable copies of Junos OS are stored in various locations: the internal flash disk, the hard drive, the removable media. The following subsections discuss the order of locations checked for a valid bootable operating system.
Boot Order for Devices
Information about the boot order for the various devices with Routing Engines is given in this section in alphabetical order of the device families.
NOTE: For information about which Routing Engines are supported by each device, see https:// www.juniper.net/documentation/en_US/release-independent/ junos/topics/reference/general/ routing-engine-m-mx-t-series-support-by-chassis.html.
The ACX Series routers attempt to boot from the storage media in the following order: 1. USB storage media device 2. Dual, internal NAND flash device (first da0s1, then da0s2) The router attempts to boot from the storage media in the following order: MX80 routers attempt to boot from the storage media in the following order: 1. USB media emergency boot device 2. Dual, internal NAND flash device (first da0, then da1) MX104 routers attempt to boot from the storage media in the following order: 1. USB storage media device 2. Internal NAND flash device (da0) The M Series and MX Series with a Routing Engine that has a solid-state drive (SSD) attempt to boot from the storage media in the following order: 1. USB media emergency boot device (if present) 2. CompactFlash card

79
3. Solid-state drive (SSD) in the SSD slot 1 or SSD slot 2 (if present) The M Series and MX Series (except for the MX80 routers and the MX104 routers) routers with a Routing Engine that has a hard disk attempt to boot from the storage media in the following order: 1. Removable media emergency boot device, such as a PC Card (if present) 2. CompactFlash card (if present) 3. Hard disk The PTX Series Packet Transport Routers attempt to boot from the storage media in the following order: 1. USB media emergency boot device 2. CompactFlash card 3. Solid-state drive (SSD) in the Disk 1 slot (if present) 4. Storage media available on the LAN The T Series and TX Matrix routers with a Routing Engine that has a hard disk attempt to boot from the storage media in the following order: 1. Removable media emergency boot device, such as a PC Card (if present) 2. CompactFlash card (if present) 3. Hard disk The T Series routers with a Routing Engine that has a solid-state drive (SSD), and TX Matrix Plus routers attempt to boot from the storage media in the following order: 1. USB media emergency boot device 2. CompactFlash card (if present) 3. Solid-state drive (SSD) in the Disk 1 slot (if present)
NOTE: The Disk 2 slot is not currently supported.
4. Storage media available on the LAN

80
Booting from an Alternate Boot Device

NOTE: Do not insert an emergency boot device during normal operations. The router does not operate normally when it is booted from an emergency boot device.

If the router boots from an alternate boot device, Junos OS displays a message indicating this when you log in to the router. For example, the following message shows that the software booted from the hard disk (/dev/ad1s1a):

login: username Password: password Last login: date on terminal
--- Junos 8.0 R1 built date ----- NOTICE: System is running on alternate media device (/dev/ad2s1a).
This situation results when the router detects a problem with the primary boot device--usually the CompactFlash card--that prevents it from booting, and consequently boots from the alternate boot device (the hard disk drive). When this happens, the primary boot device is removed from the list of candidate boot devices. The problem is usually a serious hardware error. We recommend you contact the Juniper Networks Technical Assistance Center (JTAC).

NOTE: On MX104 routers, if the router boots from an alternate boot device, Junos OS does not display any message indicating this when you log in to the router.

When the router boots from the alternate boot device, the software and configuration are only as current as the most recent request system snapshot command. However, if the mirror-flash-on-disk command was enabled, then the hard disk drive contains a synchronized, mirror image of the compact flash drive and therefore the current software and configuration.

Release History Table

Release

Description

20.3R1 Evolved Starting in Junos OS Evolved 20.3R1, install packages are available in limited editions.

81

12.1X46

SRX100, SRX110, SRX210, SRX220, and SRX240 devices with 2 GB RAM cannot be upgraded to any Junos OS 12.1X46 Release after 12.1X46-D65. Attempting to upgrade to this release on devices with 2 GB RAM will trigger the following error: ERROR: Unsupported platform for 12.1X46 releases after 12.1X46-D65

12.1X45-D10 Junos OS Release 12.1X45 and later do not support single-root partitioning

RELATED DOCUMENTATION Storage Media and Routing Engines | 389
Preparing for Software Installation and Upgrade

IN THIS SECTION
Upgrade or Reinstall Junos OS | 82 Validating the Configuration Image Before Upgrading or Downgrading the Software | 97 Ensuring Sufficient Disk Space for Junos OS Upgrades on SRX Devices | 98 Verifying Junos OS and Boot Loader Software Versions on an EX Series Switch | 101 Downloading Software | 107 Reinstall Junos OS | 112 Reconfigure Junos OS | 113

Before you install or upgrade Junos OS, you must ensure some basic checks such as sufficient disk space availability and backing up configurations in place.

82
Upgrade or Reinstall Junos OS
IN THIS SECTION Checklist for Reinstalling Junos OS | 82 Log the Software Version Information | 84 Log the Hardware Version Information | 86 Log the Chassis Environment Information | 88 Log the System Boot-Message Information | 89 Log the Active Configuration | 92 Log the Interfaces on the Router | 93 Log the BGP, IS-IS, and OSPF Adjacency Information | 94 Log the System Storage Information | 96

Checklist for Reinstalling Junos OS
Table 4 on page 82 provides links and commands for reinstalling Junos OS. Table 4: Checklist for Reinstalling Junos OS

Tasks

Command or Action

Before You Reinstall Junos OS "Log the Software Version Information"

show version | save filename

"Log the Hardware Version Information"

show chassis hardware | save filename

"Log the Chassis Environment Information"

show chassis environment | save filename

"Log the System Boot-Message Information"

show system boot-messages | save filename

"Log the Active Configuration"

show configuration | save filename

83

Table 4: Checklist for Reinstalling Junos OS (Continued)

Tasks

Command or Action

"Log the Interfaces on the Router"

show interface terse | save filename

"Log the BGP, IS-IS, and OSPF Adjacency Information"

show bgp summary | save filename show isis adjacency brief | save filename show ospf neighbor brief | save filename

"Log the System Storage Information"

show system storage | save filename

Back Up the Currently Running and Active File System

request system snapshot

"Reinstall Junos OS"

Insert your removable medium and reboot the system.

"Reconfigure Junos OS"

"Configure Host Names, Domain Names, and IP Addresses"

Log in as root. Start the CLI.

Enter configuration mode: configure set system host-name host-name set system domain-name domain-name set interfaces fxp0 unit 0 family inet address address/prefix-length set system backuprouter address set system name-server address

"Protecting Network Security by Configuring the Root Password"

set system root-authentication plain-text-password set system root-authentication encrypted-password password set system root-authentication ssh-rsa key commit exit

84

Table 4: Checklist for Reinstalling Junos OS (Continued)

Tasks

Command or Action

"Check Network Connectivity"

ping address

"Copy Backup Configurations to the Router"

file copy var/tmp configure
[edit] load merge /config/filename or load replace / config/filename
[edit] commit

After You Reinstall Junos OS

Compare Information Logged Before and After the Reinstall

show version | save filename
show chassis hardware | save filename show chassis environment | save filename

show system boot-messages | save filename show configuration | save filename

show interfaces terse | save filename

show bgp summary show isis adjacency brief show ospf neighbor brief | save filename

show system storage | save filename

Back Up the New Software

request system snapshot

Log the Software Version Information
IN THIS SECTION Purpose | 85

85
Action | 85 Meaning | 86
Purpose
The purpose of this action is to log the Junos OS version information.
Action
Use the following Junos OS CLI operational mode command:
user@host> show version | save filename
Sample Output
user@host> show version | save test Wrote 39 lines of output to `test'
user@host> show version Hostname: my-router.net Model: m10 JUNOS Base OS boot [5.0R5] JUNOS Base OS Software Suite [5.0R5] JUNOS Kernel Software Suite [5.0R5] JUNOS Routing Software Suite [5.0R5] JUNOS Packet Forwarding Engine Support [5.0R5] JUNOS Crypto Software Suite [5.0R5] JUNOS Online Documentation [5.0R5] KERNEL 5.0R5 #0 built by builder on 2002-03-02 05:10:28 UTC MGD release 5.0R5 built by builder on 2002-03-02 04:45:32 UTC CLI release 5.0R5 built by builder on 2002-03-02 04:44:22 UTC CHASSISD release 5.0R5 built by builder on 2002-03-02 04:43:37 UTC DCD release 5.0R5 built by builder on 2002-03-02 04:42:47 UTC RPD release 5.0R5 built by builder on 2002-03-02 04:46:17 UTC SNMPD release 5.0R5 built by builder on 2002-03-02 04:52:26 UTC MIB2D release 5.0R5 built by builder on 2002-03-02 04:45:37 UTC APSD release 5.0R5 built by builder on 2002-03-02 04:43:31 UTC VRRPD release 5.0R5 built by builder on 2002-03-02 04:52:34 UTC

86
ALARMD release 5.0R5 built by builder on 2002-03-02 04:43:24 UTC PFED release 5.0R5 built by builder on 2002-03-02 04:46:06 UTC CRAFTD release 5.0R5 built by builder on 2002-03-02 04:44:30 UTC SAMPLED release 5.0R5 built by builder on 2002-03-02 04:52:20 UTC ILMID release 5.0R5 built by builder on 2002-03-02 04:45:21 UTC BPRELAYD release 5.0R5 built by builder on 2002-03-02 04:42:41 UTC RMOPD release 5.0R5 built by builder on 2002-03-02 04:46:11 UTC jkernel-dd release 5.0R5 built by builder on 2002-03-02 04:41:07 UTC jroute-dd release 5.0R5 built by builder on 2002-03-02 04:41:21 UTC jdocs-dd release 5.0R5 built by builder on 2002-03-02 04:39:11 UTC
Meaning
The sample output shows the hostname, router model, and the different Junos OS packages, processes, and documents.
Log the Hardware Version Information
IN THIS SECTION Purpose | 86 Action | 87 Sample Output | 87 Meaning | 88
Purpose
You should log hardware version information in the rare event that a router cannot successfully reboot and you cannot obtain the Routing Engine serial number. The Routing Engine serial number is necessary for Juniper Networks Technical Assistance Center (JTAC) to issue a return to manufacturing authorization (RMA). Without the Routing Engine serial number, an onsite technician must be dispatched to issue the RMA.

87

Action To log the router chassis hardware version information, use the following Junos OS CLI operational mode command:
user@host> show chassis hardware | save filename

Sample Output
The output for the M-series routers varies depending on the chassis components of each router. All routers have a chassis, midplanes or backplanes, power supplies, and Flexible PIC Concentrators (FPCs). Refer to the hardware guides for information about the different chassis components.

user@host> show chassis hardware | save test Wrote 43 lines of output to `test'

user@host> show chassis hardware

Item

Version Part number

Chassis

Midplane

REV 02 710-001245

FPM CMB

REV 01 710-001642

FPM Display

REV 01 710-001647

CIP

REV 02 710-001593

PEM 0

Rev 01 740-001243

PEM 1

Rev 01 740-001243

PCG 0

REV 01 710-001568

PCG 1

REV 01 710-001568

Host 1

MCS 1

REV 03 710-001226

SFM 0 SPP

REV 04 710-001228

SFM 0 SPR

REV 02 710-001224

SFM 1 SPP

REV 04 710-001228

SFM 1 SPR

REV 01 710-001224

FPC 0

REV 03 710-001255

CPU

REV 02 710-001217

PIC 1

REV 05 750-000616

PIC 2

REV 05 750-000616

PIC 3

REV 01 750-000616

FPC 1

REV 02 710-001611

CPU

REV 02 710-001217

PIC 0

REV 03 750-001900

Serial number 101 S/N AB4107 S/N AA2911 S/N AA2999 S/N AA9563 S/N KJ35769 S/N KJ35765 S/N AA9794 S/N AA9804 da000004f8d57001 S/N AA9777 S/N AA2975 S/N AA9838 S/N AA2860 S/N AB0139 S/N AA9806 S/N AA9590 S/N AA1527 S/N AA1535 S/N AA1519 S/N AA9523 S/N AA9571 S/N AA9626

Description M160
DC DC
teknor
Internet Processor I Internet Processor I FPC Type 1 1x OC-12 ATM, MM 1x OC-12 ATM, MM 1x OC-12 ATM, MM FPC Type 2 1x STM-16 SDH, SMIR

88

PIC 1 FPC 2
CPU PIC 0

REV 01 710-002381 S/N AD3633

REV 03 REV 01

710-001217

S/N AB3329

2x G/E, 1000 BASE-SX FPC Type OC192
1x OC-192 SM SR-2

Meaning
The sample output shows the hardware inventory for an M160 router with a chassis serial number of 101. For each component, the output shows the version number, part number, serial number, and description.
Log the Chassis Environment Information

IN THIS SECTION
Action | 88 Sample Output | 88 Meaning | 89

Action
To log the router chassis environment information, use the following Junos OS CLI operational mode command:

user@host> show chassis environment | save filename

Sample Output The following example shows output from the show chassis environment command for an M5 router:

user@m5-host> show chassis environment | save test Wrote 14 lines of output to `test'

user@m5-host> show chassis environment

Class Item

Status

Power Power Supply A

OK

Measurement

89

Power Supply B

OK

Temp FPC Slot 0

OK

32 degrees C / 89 degrees F

FEB

OK

31 degrees C / 87 degrees F

PS Intake

OK

26 degrees C / 78 degrees F

PS Exhaust

OK

31 degrees C / 87 degrees F

Fans Left Fan 1

OK

Spinning at normal speed

Left Fan 2

OK

Spinning at normal speed

Left Fan 3

OK

Spinning at normal speed

Left Fan 4

OK

Spinning at normal speed

Meaning
The sample output shows the environmental information about the router chassis, including the temperature and information about the fans, power supplies, and Routing Engine.
Log the System Boot-Message Information

IN THIS SECTION
Action | 89 Sample Output | 89 Meaning | 91

Action To log the system boot-message information, use the following Junos OS CLI operational mode command:
user@host> show system boot-messages | save filename
Sample Output
user@host> show system boot-messages | save test Wrote 80 lines of output to `test' user@host> show system boot-messages

90

Copyright (c) 1992-1998 FreeBSD Inc. Copyright (c) 1996-2000 Juniper Networks, Inc. All rights reserved. Copyright (c) 1982, 1986, 1989, 1991, 1993
The Regents of the University of California.

All rights reserved.

JUNOS 4.1-20000216-Zf8469 #0: 2000-02-16 12:57:28 UTC tlim@device1.example.com:/p/build/20000216-0905/4.1/release_kernel/sys/
compile/GENERIC CPU: Pentium Pro (332.55-MHz 686-class CPU)
Origin = "GenuineIntel" Id = 0x66a Stepping=10

Features=0x183f9ff<FPU,VME,DE,PSE,TSC,MSR,PAE,MCE,CX8,SEP,MTRR,PGE,MCA,CMOV,<b16> ,<b17>,MMX,<b24>> Teknor CPU Card Recognized real memory = 805306368 (786432K bytes) avail memory = 786280448 (767852K bytes) Probing for devices on PCI bus 0: chip0 <generic PCI bridge (vendor=8086 device=7192 subclass=0)> rev 3 class 60000 on pci0:0:0 chip1 <Intel 82371AB PCI-ISA bridge> rev 1 class 60100 on pci0:7:0 chip2 <Intel 82371AB IDE interface> rev 1 class 10180 on pci0:7:1 chip3 <Intel 82371AB USB interface> rev 1 class c0300 int d irq 11 on pci0:7:2 smb0 <Intel 82371AB SMB controller> rev 1 class 68000 on pci0:7:3 pcic0 <TI PCI-1131 PCI-CardBus Bridge> rev 1 class 60700 int a irq 15 on pci0:13:0 TI1131 PCI Config Reg: [pci only][FUNC0 pci int] pcic1 <TI PCI-1131 PCI-CardBus Bridge> rev 1 class 60700 int b irq 12 on pci0:13:1 TI1131 PCI Config Reg: [pci only][FUNC1 pci int] fxp0 <Intel EtherExpress Pro 10/100B Ethernet> rev 8 class 20000 int a irq 12 on pci0:16:0 chip4 <generic PCI bridge (vendor=1011 device=0022 subclass=4)> rev 4 class 60400 on pci0:17:0 fxp1 <Intel EtherExpress Pro 10/100B Ethernet> rev 8 class 20000 int a irq 10 on pci0:19:0 Probing for devices on PCI bus 1:mcs0 <Miscellaneous Control Subsystem> rev 12 class ff0000 int a irq 12 on pci1:13:0 fxp2 <Intel EtherExpress Pro 10/100B Ethernet> rev 8 class 20000 int a irq 10 on pci1:14:0 Probing for devices on the ISA bus: sc0 at 0x60-0x6f irq 1 on motherboard sc0: EGA color <16 virtual consoles, flags=0x0>

91
ed0 not found at 0x300 ed1 not found at 0x280 ed2 not found at 0x340 psm0 not found at 0x60 sio0 at 0x3f8-0x3ff irq 4 flags 0x20010 on isa sio0: type 16550A, console sio1 at 0x3e8-0x3ef irq 5 flags 0x20000 on isa sio1: type 16550A sio2 at 0x2f8-0x2ff irq 3 flags 0x20000 on isa sio2: type 16550A pcic0 at 0x3e0-0x3e1 on isa PC-Card ctlr(0) TI PCI-1131 [CardBus bridge mode] (5 mem & 2 I/O windows) pcic0: slot 0 controller I/O address 0x3e0 npx0 flags 0x1 on motherboard npx0: INT 16 interface fdc0: direction bit not set fdc0: cmd 3 failed at out byte 1 of 3 fdc0 not found at 0x3f0 wdc0 at 0x1f0-0x1f7 irq 14 on isa wdc0: unit 0 (wd0): <SunDisk SDCFB-80>, single-sector-i/o wd0: 76MB (156672 sectors), 612 cyls, 8 heads, 32 S/T, 512 B/S wdc0: unit 1 (wd1): <IBM-DCXA-210000> wd1: 8063MB (16514064 sectors), 16383 cyls, 16 heads, 63 S/T, 512 B/S wdc1 not found at 0x170 wdc2 not found at 0x180 ep0 not found at 0x300 fxp0: Ethernet address 00:a0:a5:12:05:5a fxp1: Ethernet address 00:a0:a5:12:05:59 fxp2: Ethernet address 02:00:00:00:00:01 swapon: adding /dev/wd1s1b as swap device Automatic reboot in progress... /dev/rwd0s1a: clean, 16599 free (95 frags, 2063 blocks, 0.1% fragmentation) /dev/rwd0s1e: clean, 9233 free (9 frags, 1153 blocks, 0.1% fragmentation) /dev/rwd0s1a: clean, 16599 free (95 frags, 2063 blocks, 0.1% fragmentation) /dev/rwd1s1f: clean, 4301055 free (335 frags, 537590 blocks, 0.0% fragmentation)
Meaning
The sample output shows the initial messages generated by the system kernel upon boot. This is the content of the /var/run/dmesg.boot file.

92
Log the Active Configuration
IN THIS SECTION Action | 92 Sample Output | 92 Meaning | 92
Action To log the active configuration on the router, use the following Junos OS CLI operational mode command:
user@host> show configuration | save filename
Sample Output
user@host> show configuration | save test Wrote 4076 lines of output to `test'
user@host> show configuration system { host-name lab8; domain-name device1.example.com; backup-router 10.1.1.254;
time-zone America/Los_Angeles; default-address-selection;
dump-on-panic; name-server { [...Output truncated...]
Meaning The sample output shows the configuration currently running on the router, which is the last committed configuration.

93
Log the Interfaces on the Router
IN THIS SECTION Action | 93 Sample Output | 93 Meaning | 94

Action To log the interfaces on the router, use the following Junos OS CLI operational mode command:

user@host> show interface terse | save filename

Sample Output

user@host> show interfaces terse | save test Wrote 81 lines of output to `test'

user@host> show interfaces terse

Interface

Admin Link Proto Local

Remote

at-1/3/0

up up

at-1/3/0.0

up up inet 203.0.113.1

--> 203.0.113.2

iso

fxp0

up up

fxp0.0

up up inet 10.168.5.59/24

gre

down up

ipip

down up

lo0

up up

lo0.0

up up inet 127.0.0.1

--> 0/0

iso 47.0005.80ff.f800.0000.0108.0001.1921.6800.5059.00

so-1/2/0

up down

so-1/2/1

down down

so-1/2/2

down down

so-1/2/3

down down

so-2/0/0

up up

so-2/0/0.0

up up inet 192.2.3.4

--> 192.2.3.5

94
iso [...Output truncated...]
Meaning The sample output displays summary information about the physical and logical interfaces on the router.
Log the BGP, IS-IS, and OSPF Adjacency Information
IN THIS SECTION Purpose | 94 Action | 94 Sample Output 1 | 95 Sample Output 2 | 95 Sample Output 3 | 95 Meaning | 96
Purpose The following commands log useful information about Border Gateway Protocol (BGP), Intermediate System-to-Intermediate System (IS-IS), and Open Shortest Path First (OSPF) protocols. If you have other protocols installed, such as Multiprotocol Label Switching (MPLS), Resource Reservation Protocol (RSVP), or Protocol Independent Multicast (PIM), you also might log summary information for them.
Action To log the protocol peer information, use the following Junos OS CLI operational mode commands:
user@host> show bgp summary | save filename user@host> show isis adjacency brief | save filename user@host> show ospf neighbor brief | save filename

95

Sample Output 1

user@host> show bgp summary | save test Wrote 45 lines of output to `test'

user@host> show bgp summary

Groups: 1 Peers: 1 Down peers: 0

Table

Tot Paths Act Paths Suppressed History Damp State Pending

inet.0

4

4

0

0

0

0

Peer

AS

InPkt

OutPkt OutQ Flaps Last Up/Dwn State|

#Active/Received/Damped..

9.9.3.1

2

2627

2628

0

0 21:50:12

4/4/0

0/0/0

Sample Output 2

user@host> show isis adjacency brief | save test Wrote 7 lines of output to `test'

user@host> show isis adjacency brief

IS-IS adjacency database:

Interface System

L State

so-1/0/0.0 1921.6800.5067 2 Up

so-1/1/0.0 1921.6800.5067 2 Up

so-1/2/0.0 1921.6800.5067 2 Up

so-1/3/0.0 1921.6800.5067 2 Up

so-2/0/0.0 1921.6800.5066 2 Up

so-2/1/0.0 1921.6800.5066 2 Up

so-2/2/0.0 1921.6800.5066 2 Up

so-2/3/0.0 1921.6800.5066 2 Up

so-5/0/0.0 ranier

2 Up

Hold (secs) SNPA 13 25 20 19 19 17 20 20 17

Sample Output 3

user@host> show ospf neighbor brief | save test Wrote 10 lines of output to `test'

user@host> show ospf neighbor brief

Address

Intf

State

ID

Pri Dead

96

10.168.254.225 10.168.254.230 10.168.254.229 10.1.1.129 10.1.1.131 10.1.2.1 10.1.2.81

fxp3.0 fxp3.0 fxp3.0 fxp2.0 fxp2.0 fxp1.0 fxp0.0

2Way Full Full Full Full Full Full

10.250.240.32 10.250.240.8 10.250.240.35 10.250.240.12 10.250.240.11 10.250.240.9 10.250.240.10

128 36 128 38 128 33 128 37 128 38 128 32 128 33

Meaning
Sample output 1 displays summary information about BGP and its neighbors. Sample output 2 displays information about IS-IS neighbors. Sample output 3 displays information about all OSPF neighbors.
Log the System Storage Information

IN THIS SECTION
Action | 96 Sample Output | 96 Meaning | 97

Action
To log the system storage statistics for the amount of free disk space in the router's file system, use the following Junos OS CLI operational mode command:

user@host> show system storage | save filename

Sample Output

user@host> show system storage | save test Wrote 14 lines of output to `test'

user@host> show system storage

Filesystem 1K-blocks

Used

/dev/ad0s1a

65687 26700

Avail Capacity Mounted on 33733 44% /

97

devfs /dev/vn1 /dev/vn2 /dev/vn3 /dev/vn4 /dev/vn5 /dev/vn6 mfs:2373 /dev/ad0s1e procfs /dev/ad1s1f

16 9310 8442 11486 5742 1488
792 1015815
25263 4
9825963

16 9310 8442 11486 5742 1488
792 3
11 4
1811085

0 0 0 0 0 0 0 934547 23231 0 7228801

100% 100% 100% 100% 100% 100% 100%
0% 0% 100% 20%

/dev/ /packages/mnt/jbase /packages/mnt/jkernel-5.0R5.1 /packages/mnt/jpfe-5.0R5.1 /packages/mnt/jroute-5.0R5.1 /packages/mnt/jcrypto-5.0R5.1 /packages/mnt/jdocs-5.0R5.1 /tmp /config /proc /var

Meaning
The sample output displays statistics about the amount of free disk space in the router's file system. Values are displayed in 1024-byte (1-KB) blocks.

Validating the Configuration Image Before Upgrading or Downgrading the Software
Here are some validation guidelines to keep in mind:
· Validation is set to on by default. You do not need to configure it or issue any command to start it on a switch that supports image validation. You can disable validation (the procedure is given below) and then re-enable it.
· Validation slows down the upgrade or downgrade process by as much as 7 minutes.
· Image validation is supported only on the jinstall package.
· If you invoke validation from an image that does not support validation, the new image is loaded but validation does not occur.
· Validation does not work in a downgrade to an image that does not support validation if your system is configured for graceful routing switchover (GRES) or if you run image loading without nonstop software upgrade (NSSU). See the procedure below for steps to use validation in this type of scenario.
If you upgrade or downgrade the Junos OS image on a switch that supports configuration image validation (see Feature Explorer for feature support per EX Series switch), the system validates that the existing configuration is compatible with the new image before the actual upgrade or downgrade commences.

98
Benefits of image validation--If validation fails, the new image is not loaded, and an error message provides information about the failure. If you upgrade or downgrade the software on a system that does not support validation, configuration incompatibilities between the existing and new image or insufficient memory to load the new image might cause the system to lose its current configuration or go offline. To disable validation, re-enable or invoke validation manually, or use validation when downgrading to an image that does not support it: · To disable validation, issue request system software add image-name reboot no-validate command. · To re-enable or invoke validation manually, choose one of the following methods:
· Issue request system software add image-name. · Issue request system software nonstop-upgrade image-name. · Issue request system software validate to run just configuration validation. · To use validation when downgrading to an image that does not support it, choose one of the following methods: · Remove the graceful-switchover configuration and then issue the request system software add
image-name reboot command. · Use NSSU by issuing the request system software nonstop-upgrade image-name command.
Ensuring Sufficient Disk Space for Junos OS Upgrades on SRX Devices
IN THIS SECTION Verifying Available Disk Space on SRX Series Devices | 98 Cleaning Up the System File Storage Space | 99
Before you begin upgrading Junos OS on an SRX Series device, perform the following tasks:
Verifying Available Disk Space on SRX Series Devices
The amount of free disk space necessary to upgrade a device with a new version of Junos OS can vary from one release to another. Check the Junos OS software version you are installing to determine the free disk space requirements.

99

If the amount of free disk space on a device is insufficient for installing Junos OS, you might receive a warning similar to the following messages, that the /var filesystem is low on free disk space:
WARNING: The /var filesystem is low on free disk space.
WARNING: This package requires 1075136k free, but there is only 666502k available.
To determine the amount of free disk space on the device, issue the show system storage detail command. The command output displays statistics about the amount of free disk space in the device file systems.
A sample of the show system storage detail command output is shown below:

user@host> show system storage detail

Filesystem /dev/da0s2a devfs /dev/md0 /cf devfs procfs /dev/bo0s3e /dev/bo0s3f /dev/md1 /cf/var/jail /cf/var/log devfs /dev/md2 utm /dev/md3

1024-blocks 300196
1 409000 300196
1 4 25004 350628 171860 350628 350628 1 40172
1884

Used 154410
1 409000 154410
1 4 52 178450 16804 178450 178450 1 4

Avail Capacity Mounted on

121772

56% /

0

100% /dev

0

100% /junos

121772

56% /junos/cf

0

100% /junos/dev/

0

100% /proc

22952

0% /config

144128

55% /cf/var

141308

11% /mfs

144128

55% /jail/var

144128

55% /jail/var/log

0

100% /jail/dev

36956

0% /mfs/var/run/

138

1596

8% /jail/mfs

Cleaning Up the System File Storage Space
When the system file storage space on the device is full, rebooting the device does not solve the problem. The following error message is displayed during a typical operation on the device after the file storage space is full.

user@host% cli user@host> configure/var: write failed, filesystem is full
You can clean up the file storage on the device by deleting system files using the request system storage cleanup command as shown in following procedure:

100

1. Request to delete system files on the device.

user@host> request system storage cleanup The list of files to be deleted is displayed.

List of files to delete:

Size Date

Name

11B Oct 28 23:40 /var/jail/tmp/alarmd.ts

92.4K Jan 11 17:12 /var/log/chassisd.0.gz

92.4K Jan 11 06:06 /var/log/chassisd.1.gz

92.5K Jan 10 19:00 /var/log/chassisd.2.gz

92.5K Jan 10 07:53 /var/log/chassisd.3.gz

92.2K Jan 10 15:00 /var/log/hostlogs/auth.log.1.gz

92.2K Jan 1 18:45 /var/log/hostlogs/auth.log.2.gz

92.1K Jan 4 17:30 /var/log/hostlogs/auth.log.3.gz

92.2K Jan 1 18:45 /var/log/hostlogs/auth.log.4.gz

79.0K Jan 12 01:59 /var/log/hostlogs/daemon.log.1.gz

78.8K Jan 11 23:15 /var/log/hostlogs/daemon.log.2.gz

78.7K Jan 11 20:30 /var/log/hostlogs/daemon.log.3.gz

79.1K Jan 11 17:44 /var/log/hostlogs/daemon.log.4.gz

59.1K Jan 11 21:59 /var/log/hostlogs/debug.1.gz

59.2K Jan 11 17:44 /var/log/hostlogs/debug.2.gz

59.2K Jan 11 13:29 /var/log/hostlogs/debug.3.gz

59.3K Jan 11 09:14 /var/log/hostlogs/debug.4.gz

186.6K Oct 20 16:31 /var/log/hostlogs/kern.log.1.gz

238.3K Jan 11 23:15 /var/log/hostlogs/lcmd.log.1.gz

238.4K Jan 11 17:30 /var/log/hostlogs/lcmd.log.2.gz

238.6K Jan 11 11:45 /var/log/hostlogs/lcmd.log.3.gz

238.5K Jan 11 06:00 /var/log/hostlogs/lcmd.log.4.gz

372.5K Jan 11 17:00 /var/log/hostlogs/syslog.1.gz

372.5K Jan 11 04:45 /var/log/hostlogs/syslog.2.gz

371.9K Jan 10 16:30 /var/log/hostlogs/syslog.3.gz

372.7K Jan 10 04:15 /var/log/hostlogs/syslog.4.gz

10.1K Jan 12 02:03 /var/log/messages.0.gz

55.1K Jan 6 21:25 /var/log/messages.1.gz

81.5K Dec 1 21:30 /var/log/messages.2.gz

Delete these files ? [yes,no] (no)

101
2. Enter the option yes to proceed with deleting of the files.
Verifying Junos OS and Boot Loader Software Versions on an EX Series Switch
IN THIS SECTION Verifying the Number of Partitions and File System Mountings | 101 Verifying the Loader Software Version | 103 Verifying Which Root Partition Is Active | 104 Verifying the Junos OS Version in Each Root Partition | 105
Before or after upgrading or downgrading Junos OS, you might need to verify the Junos OS version. You might also need to verify the boot loader software version if you are upgrading to or downgrading from a release that supports resilient dual-root partitions (Junos OS Release 10.4R3 and later). This topic includes:
Verifying the Number of Partitions and File System Mountings
IN THIS SECTION Purpose | 101 Action | 102 Meaning | 103
Purpose Between Junos OS Release 10.4R2 and Release 10.4R3, upgrades were made to further increase resiliency of root partitions, which required reformatting the disk from three partitions to four partitions. If your switch is running Release 10.4R2 or earlier, it has three partitions, and if it is running Release 10.4R3 or later, it has four partitions.

102

Action
Verify how many partitions the disk has, as well as where each file system is mounted, by using the following command:

user@switch> show system storage

fpc0:

-----------------------------------------------------------------------

Filesystem Size Used Avail Capacity Mounted on

/dev/da0s1a 184M 124M 45M

73% /

devfs

1.0K 1.0K 0B

100% /dev

/dev/md0

37M 37M 0B

100% /packages/mnt/jbase

/dev/md1

18M 18M 0B

100% /packages/mnt/jcrypto-

ex-10.4I20110121_0509_hbRPSRLI15184421081

/dev/md2 6.1M 6.1M 0B

100% /packages/mnt/jdocs-

ex-10.4I20110121_0509_hbRPSRLI15184421081

/dev/md3 154M 154M 0B

100% /packages/mnt/jkernel-

ex-10.4I20110121_0509_hbRPSRLI15184421081

/dev/md4

23M 23M 0B

100% /packages/mnt/jpfe-

ex42x-10.4I20110121_0509_hbRPSRLI15184421081

/dev/md5

46M 46M 0B

100% /packages/mnt/jroute-

ex-10.4I20110121_0509_hbRPSRLI15184421081

/dev/md6

28M 28M 0B

100% /packages/mnt/jswitch-

ex-10.4I20110121_0509_hbRPSRLI15184421081

/dev/md7

22M 22M 0B

100% /packages/mnt/jweb-

ex-10.4I20110121_0509_hbRPSRLI15184421081

/dev/md8

126M 10.0K 116M

0% /tmp

/dev/da0s3e 123M 632K 112M

1% /var

/dev/da0s3d 369M 20K 339M

0% /var/tmp

/dev/da0s4d 62M 62K 57M

0% /config

/dev/md9

118M 12M 96M

11% /var/rundb

procfs

4.0K 4.0K 0B 100% /proc

/var/jail/etc 123M 632K 112M

1% /packages/mnt/jweb-

ex-10.4I20110121_0509_hbRPSRLI15184421081/jail/var/etc

/var/jail/run 123M 632K 112M 1% /packages/mnt/jweb-

ex-10.4I20110121_0509_hbRPSRLI15184421081/jail/var/run

/var/jail/tmp 123M 632K 112M 1% /packages/mnt/jweb-

ex-10.4I20110121_0509_hbRPSRLI15184421081/jail/var/tmp

/var/tmp

369M 20K 339M 0% /packages/mnt/jweb-

ex-10.4I20110121_0509_hbRPSRLI15184421081/jail/var/tmp/uploads

103

devfs

1.0K 1.0K 0B 100% /packages/mnt/jweb-

ex-10.4I20110121_0509_hbRPSRLI15184421081/jail/dev

Meaning
The presence of the partition name containing s4d indicates that there is a fourth slice. If this were a three-slice partition scheme, in place of s1a, s3e, s3d, and s4d, you would see s1a, s1f, s2a, s2f, s3d, and s3e, and you would not see s4d.
Verifying the Loader Software Version

IN THIS SECTION
Purpose | 103 Action | 103 Meaning | 104

Purpose For the special case of upgrading from Junos OS Release 10.4R2 or earlier to Release 10.4R3 or later, you must upgrade the loader software.
Action For EX Series switches except EX8200 switches:

user@switch> show chassis firmware

Part

Type

FPC 0

uboot

1.0.0

loader

For EX8200 switches:

Version U-Boot 1.1.6 (Jan 3 2011 - 16:14:58)
FreeBSD/PowerPC U-Boot bootstrap loader 2.4

user@switch> show chassis firmware

Part

Type

FPC 0

uboot

Version U-Boot 1.1.6 (Jan 3 2011 - 16:14:58)

104

3.5.0

loader

FreeBSD/PowerPC U-Boot bootstrap loader 2.4

Meaning
For EX Series switches other than EX8200 switches, with Junos OS Release 10.4R3 or later installed:
· If there is version information following the timestamp for U-Boot (1.0.0 in the preceding example), then the loader software does not require upgrading.
· If there is no version number following the timestamp for U-boot, then the loader software requires upgrading.
NOTE: If the software version is Release 10.4R2 or earlier, no version number is displayed following the timestamp for U-boot, regardless of the loader software version installed. If you do not know whether you have installed the new loader software, we recommend that you upgrade the loader software when you upgrade the software version.

For EX8200 switches, if the version number following the timestamp for U-Boot is earlier than 3.5.0, you must upgrade the loader software when you upgrade the software version.
Verifying Which Root Partition Is Active

IN THIS SECTION
Purpose | 104 Action | 105 Meaning | 105

Purpose
Switches running Release 10.4R3 or later have resilient dual-root partition functionality, which includes the ability to boot transparently from the inactive partition if the system fails to boot from the primary root partition.
You can verify which root partition is active using the following command:

105

Action

user@switch> show system storage partitions

fpc0:

--------------------------------------------------------------------------

Boot Media: internal (da0)

Active Partition: da0s1a

Backup Partition: da0s2a Currently booted from: active (da0s1a)

Partitions information:

Partition Size Mountpoint

s1a

184M /

s2a

184M altroot

s3d

369M /var/tmp

s3e

123M /var

s4d

62M /config

s4e

unused (backup config)

Meaning The Currently booted from: field shows which root partition is active.
Verifying the Junos OS Version in Each Root Partition

IN THIS SECTION
Purpose | 105 Action | 106 Meaning | 106

Purpose
Each switch contains two root partitions. We recommend that you copy the same Junos OS version in each partition when you upgrade. In Junos OS Release 10.4R2 and earlier, you might choose to have different Junos OS release versions in each partition. You might have different versions during a software upgrade and before you have finished verifying the new software installation. To enable a smooth reboot if corruption is found in the primary root file system, ensure that the identical Junos OS images are in each root partition. For Release 10.4R2 and earlier, you must manually reboot the switch

106

from the backup root partition. However, for Release 10.4R3 and later, the switch reboots automatically from the backup root partition if it fails to reboot from the active root partition.
Action
Verify whether both root partitions contain the same image by using the following command:

user@switch> show system snapshot media internal

Information for snapshot on

internal (/dev/da0s1a) (backup)

Creation date: Jan 11 03:02:59 2012

JUNOS version on snapshot:

jbase : ex-12.2I20120305_2240_user

jcrypto-ex: 12.2I20120305_2240_user

jdocs-ex: 12.2I20120305_2240_user

jroute-ex: 12.2I20120305_2240_user

jswitch-ex: 12.2I20120305_2240_user

jweb-ex: 12.2I20120305_2240_user

Information for snapshot on

internal (/dev/da0s2a) (primary)

Creation date: Mar 6 02:24:08 2012

JUNOS version on snapshot:

jbase : ex-12.2I20120305_2240_user

jcrypto-ex: 12.2I20120305_2240_user

jdocs-ex: 12.2I20120305_2240_user

jroute-ex: 12.2I20120305_2240_user

jswitch-ex: 12.2I20120305_2240_user

jweb-ex: 12.2I20120305_2240_user

Meaning
The command shows which Junos OS version is installed on each media partition. Verify that the same version is installed on both partitions.

RELATED DOCUMENTATION Configuring Dual-Root Partitions

107
Downloading Software
IN THIS SECTION Downloading Software Using a Browser | 107 Downloading Software Using the Command-Line Interface | 108 Downloading Software Using Download Manager (SRX Series Only) | 110
Downloading Software Using a Browser
You download the software package you need from the Juniper Networks Downloads page at https:// support.juniper.net/support/downloads/.
NOTE: To access the download section, you must have a service contract and an access account. If you need help obtaining an account, complete the registration form at the Juniper Networks website: https://userregistration.juniper.net/entitlement/setupAccountInfo.do.
To download the software image: 1. Using a Web browser, navigate to https://support.juniper.net/support/downloads/.
The Download Results page appears. 2. Find the software package that you want to download and click the item in the Downloads column.
A login screen appears. 3. Log in with your username and password. 4. On the Download Software page that appears, the following options are available:
· If you want to download the software on your local host, click the CLICK HERE link and save the file to your system. If you want to place the file on a remote system, you must make sure that the file can be accessible by the router, switch, or services gateway by using HTTP, FTP, or SCP. Proceed with the installation. See "Downloading Software" on page 107 for more details.
· If you want to download the software on your device, use the following procedure to download and install the software on the device. a. Click Copy to copy the generated URL to the clipboard.

108
NOTE: The URL string generated remains active only for 15 minutes.
b. Log in to your device. c. In operational mode, enter the file copy "URL" destination command.
In the command, paste the copied URL string (for URL) and then enter /var/tmp (as the destination on your hard disk). Example:
NOTE: Ensure that the URL string is enclosed within quotation marks. Also ensure that there is sufficient free space available on the device.
The software image is downloaded on your device. d. (Optional) Validate the software image by using the request system software validate package-
name command. Example:
user@host> request system software validate /var/tmp/junos-install-mx-x86-32-17.3R1.10.tgz
For more details, see request system software validate. e. Install the software by using the request system software add package-name command.
Example:
user@host> request system software add /var/tmp/junos-install-mx-x86-32-17.3R1.10.tgz
Your software is installed on the device.
Downloading Software Using the Command-Line Interface
Download the software package you need from the Juniper Networks Downloads page athttps:// support.juniper.net/support/downloads/, and place the package on a local system. You can then transfer the downloaded package to the device using either the router or switch command-line interface, or the local system command-line interface.

109
NOTE: To access the download section, you must have a service contract and an access account. If you need help obtaining an account, complete the registration form at the Juniper Networks website: https://userregistration.juniper.net/entitlement/setupAccountInfo.do.
Before you transfer the software package, ensure that the FTP service is enabled on the device. Enable the FTP service using the set system services ftp command:
user@host# set system services ftp To transfer the software package using the device command-line interface: 1. From the router or switch command line, initiate an FTP session with the local system (host) where
the package is located by using the ftp command:
user@host> ftp host
host is the hostname or address of the local system. 2. Log in with your customer support­supplied username and password:
User Name: username 331 Password required for username. Password: password After your credentials are validated, the FTP session opens. 3. Navigate to the software package location on the local system, and transfer the package by using the get command:
user@host> get installation-package
Following is an example of an installation-package name: junos-install-mx-x86-32-17.3R1.10.tgz 4. Close the FTP session by using the bye command:
user@host> bye Goodbye

110
To transfer the package by using the local system command-line interface: 1. From the local system command line, initiate an FTP session with the device using the ftp command:
user@host> ftp host
host is the hostname or address of the router or switch. 2. Log in with your customer support­supplied username and password:
User Name: username 331 Password required for username. Password: password
After your credentials are validated, the FTP session opens. 3. Navigate to the software package location on the local system, and transfer the package by using the
put command:
user@host> put installation-package
Following is an example of an installation-package name: junos-install-mx-x86-32-17.3R1.10.tgz 4. Close the FTP session by using the bye command:
user@host> bye Goodbye
Downloading Software Using Download Manager (SRX Series Only)
This download manager feature facilitates download of large files over low-bandwidth links. It enables you to download large Junos OS packages over low-bandwidth/flaky links so that the system can be upgraded. This feature allows you to download multiple files while monitoring their status and progress individually. It takes automatic action when required and displays status information when requested. The download manager is supported on SRX300, SRX320, SRX340, SRX345, and SRX380 devices. Be aware of the following considerations when using the download manager: · When no download limit is specified for a specific download or for all downloads, a download uses all
available network bandwidth.

111
· Because the download limit that you set indicates an average bandwidth limit, it is possible that certain bursts might exceed the specified limit.
· When a download from an HTTP server fails, the server returns an HTML page. Occasionally, the error page is not recognized as an error page and is downloaded in place of the Junos image file.
· Remote server logins and passwords are stored by the download manager for the duration of a download. To encrypt these credentials provided along with the login keyword, define an encryption key with the request system set-encryption-key command. Any changes to encryption settings while download is in progress can cause the download to fail.
· A download command issued on a particular node in a chassis cluster takes place only on that node and is not propagated to the other nodes in the cluster. Downloads on different nodes are completely independent of each other. In the event of a failover, a download continues only if the server remains reachable from the node from which the command was issued. If the server is no longer reachable on that node, the download stops and returns an error.
NOTE: The download manager supports only the FTP and HTTP protocols.
The download manager acts as a substitute for the FTP utility. You can use the download manager CLI commands for all the functions where you previously used the FTP utility.
Before you begin, you must have the following:
· An FTP or HTTP server with a Junos OS image
· A server that is reachable from the device being upgraded
To download the Junos OS image to your device:
1. Use the request system download start command (set a bandwidth limit, if required). The file is saved to the /var/tmp directory on your device. You can continue to use the device while the download runs in the background.
2. To verify that the file has been downloaded, use the show system download command. The command displays the state as "completed" when the downloaded file is ready to be installed.
3. To install the downloaded image file from the /var/tmp directory, use the request system software add command.
4. If you encounter any problem with a download, use the show system download id command to obtain details about the download.
Table 2 lists the output fields for the show system download command. Use this information to diagnose problems. Output fields are listed in the approximate order in which they appear.

112

Table 5: show system download Output Fields

Output Field

Description

Status

State of the download.

Creation Time

Time the start command was issued.

Scheduled Time Time the download was scheduled to start.

Start Time

Time the download actually started (if it has already started).

Retry Time

Time for next retry (if the download is in the error state).

Error Count

Number of times an error was encountered by this download.

Retries Left

Number of times the system will retry the download automatically before stopping.

Most Recent Error Message indicating the cause of the most recent error.

Reinstall Junos OS
IN THIS SECTION Action | 112

Action
To reinstall Junos OS, follow these steps:

113
1. Insert the removable medium (boot floppy) into the router. 2. Reboot the router, either by power-cycling it or by issuing the request system reboot command from
the CLI. 3. At the following prompt, type y:
WARNING: The installation will erase the contents of your disk. Do you wish to continue (y/n)? The router copies the software from the removable medium onto your system, occasionally displaying status messages. This can take up to 10 minutes. 4. Remove the removable medium when prompted. The router reboots from the primary boot device on which the software is installed. When the reboot is complete, the router displays the login prompt.
Reconfigure Junos OS
IN THIS SECTION Configure Host Names, Domain Names, and IP Addresses | 113 Protecting Network Security by Configuring the Root Password | 115 Check Network Connectivity | 117
After you have reinstalled the software, you must copy the router's configuration files back to the router. (You also can configure the router from scratch, as described in Junos System Basics Configuration Guide) However, before you can copy the configuration files, you must establish network connectivity. To reconfigure the software, follow these steps:
Configure Host Names, Domain Names, and IP Addresses
To configure the machine name, domain name, and various addresses, follow these steps: 1. Log in as root. There is no password.

114
2. Start the CLI:
root# cli root@>
3. Enter configuration mode:
root@>configure [edit] root@#
4. Configure the name of the machine. If the name includes spaces, enclose the entire name in quotation marks (" "):
[edit] root@#set system host-name host-name
5. Configure the machine's domain name:
[edit] root@#set system domain-name domain-name
6. Configure the IP address and prefix length for the router's management Ethernet interface:
[edit] root@#set interfaces fxp0 unit 0 family inet address address | prefix-length
7. Configure the IP address of a default router. This system is called the backup router because it is used only while the routing protocol process is not running.
[edit] root@#set system backup-router address

115
8. Configure the IP address of a Domain Name Server (DNS) server:
[edit] root@# set system name-server address
Protecting Network Security by Configuring the Root Password
Configuring the root password on your Juniper Networks device helps prevent unauthorized users from making changes to your network. The root user (also referred to as superuser) has unrestricted access and full permissions within the system, so it is crucial to protect this account by setting a strong password when setting up a new device. After a new device is initially powered on, you log in as the user root with no password. The software requires configuration of the root password before it accepts a commit operation. To set the root password, you have a few options as shown in the following procedure. · Enter a plain-text password the software encrypts. · Enter a password that is already encrypted. · Enter a secure shell (ssh) public key string. The most secure options of these three are using an already encrypted password or an ssh public key string. Pre-encrypting your password or using a ssh public key string means the plain-text version of your password will never be transferred over the internet, protecting it from being intercepted by a manin-the-middle attack.
BEST PRACTICE: Optionally, instead of configuring the root password at the [edit system] hierarchy level, you can use a configuration group to strengthen security.
To set the root password: 1. Use one of these methods to configure the root password:
· To enter a plain-text password that the system encrypts for you:
[edit groups global system] root@# set root-authentication plain-text-password New Password: type password here Retype new password: retype password here

116
As you enter a plain-text password into the CLI, the device software hides it from view and encrypts it immediately. You do not have to configure the software to encrypt the password as in some other systems. In the resulting configuration, the encrypted password is marked as ## SECRET-DATA so that it cannot be seen. · To enter a password that is already encrypted:
CAUTION: Do not use the encrypted-password option unless the password is already encrypted, and you are entering the encrypted version of the password. If you accidentally configure the encrypted-password option with a plain-text password or with blank quotation marks (" "), you will not be able to log in to the device as root, and you will need to complete the root password recovery process.
[edit groups global system] root@# set root-authentication encrypted-password password
· To enter an ssh public key string:
[edit groups global system] root@# set root-authentication (ssh-dsa | ssh-ecdsa | ssh-rsa key)
2. If you used a configuration group, apply it with the command set apply-groups, replacing <group name> with the configuration group name. For example:
[edit] root@# set apply-groups <group name> 3. Commit the changes.
root@# commit
SEE ALSO Accessing a Junos OS Device the First Time

117
Check Network Connectivity
IN THIS SECTION Purpose | 117 Action | 117
Purpose Establish that the router has network connectivity. Action To check that the router has network connectivity, issue a ping command to a system on the network:
root@> ping address
If there is no response, verify that there is a route to the address using the show route command. If the address is outside your fxp0 subnet, add a static route. Once the backup configuration is loaded and committed, the static route is no longer needed and should be deleted.
RELATED DOCUMENTATION Troubleshooting Software Installation on EX Series Switches | 521 Troubleshooting a Switch That Has Booted from the Backup Junos OS Image | 527

118
Managing YANG Packages and Configurations During a Software Upgrade or Downgrade
IN THIS SECTION Backing up and Deleting the Configuration Data | 119 Restoring the YANG Packages and Configuration Data | 119
Certain devices running Junos OS enable you to load custom YANG modules on the device to add data models that are not natively supported by Junos OS. When you add, update, or delete a YANG data model, Junos OS rebuilds its schema and then validates the active configuration against the updated schema. When you upgrade or downgrade Junos OS, by default, the system validates the software package or bundle against the current configuration. During the installation, the schema for custom YANG data models is not available. As a result, if the active configuration contains dependencies on these models, the software validation fails, which causes the upgrade or downgrade to fail. In addition, devices that are running Junos OS based on FreeBSD version 6 remove custom YANG packages from the device during the software installation process. For this Junos OS variant, if the active configuration contains dependencies on custom YANG data models, the software installation fails even if you do not validate the software against the configuration, because the configuration data cannot be validated during the initial boot-time commit. For these reasons, before you upgrade or downgrade the Junos OS image on a device that has one or more custom YANG modules added to it, you must remove all configuration data corresponding to the custom YANG data models from the active configuration. After the software installation is complete, add the YANG packages and corresponding configuration data back to the device, if appropriate. The tasks are outlined in this topic.
NOTE: You do not need to delete configuration data corresponding to OpenConfig packages before upgrading or downgrading Junos OS.

119
Backing up and Deleting the Configuration Data
If the configuration contains dependencies on custom YANG data models: 1. If you plan to restore the configuration data that corresponds to the nonnative YANG data models
after the software is updated, save a copy of either the entire configuration or the configuration data corresponding to the YANG data models, as appropriate. · To save the entire configuration:
user@host> show configuration | save (filename | url)
· To save configuration data under a specific hierarchy level:
user@host> show configuration path-to-yang-statement-hierarchy | save (filename | url) 2. In configuration mode, delete the portions of the configuration that depend on the custom YANG
data models.
[edit] user@host# delete path-to-yang-statement-hierarchy 3. Commit the changes.
[edit] user@host# commit 4. Prior to performing the software installation, ensure that the saved configuration data and the YANG module and script files are saved to a local or remote location that will preserve the files during the installation and that will be accessible after the installation is complete.
Restoring the YANG Packages and Configuration Data
After the software installation is complete, load the YANG packages onto the device (where required), and restore the configuration data associated with the packages, if appropriate. During a software upgrade or downgrade, devices running Junos OS with upgraded FreeBSD preserve custom YANG packages, whereas devices running Junos OS based on FreeBSD version 6 delete the packages.

120
1. Load the YANG packages (devices running Junos OS based on FreeBSD version 6 only).
user@host> request system yang add package package-name module [modules] deviationmodule [modules] translation-script [scripts] action-script [scripts] 2. When the system prompts you to restart the Junos OS CLI, press Enter to accept the default value of yes.
... WARNING: cli has been replaced by an updated version: ... Restart cli using the new version ? [yes,no] (yes) Restarting cli ...
NOTE: To prevent CLI-related or configuration database errors, we recommend that you do not perform any CLI operations, change the configuration, or terminate the operation while a device is in the process of adding, updating, or deleting a YANG package and modifying the schema.
3. In configuration mode, load the configuration data associated with the YANG packages. For example, to load the configuration data from a file relative to the top level of the configuration statement hierarchy:
[edit] user@host# load merge (filename | url)
NOTE: For more information about loading configuration data, see the CLI User Guide.
4. Commit the changes.
[edit] user@host# commit

121
RELATED DOCUMENTATION Managing YANG Packages, Modules, and Scripts on Devices Running Junos OS
Installing Software on Routing Devices
IN THIS SECTION Installing the Software Package on a Router with a Single Routing Engine | 121 Installing the Software Package on a Device with Redundant Routing Engines | 123
Routing devices are delivered with Junos OS preinstalled on them. As new features and software fixes become available, you must upgrade Junos OS to use them. You can install software on single and redundant routing engines.
Installing the Software Package on a Router with a Single Routing Engine
Before you install a new software release on a device, you should back up the current system. In Junos OS Evolved, multiple releases of the software can be installed on the device simultaneously as long as there is space. If there is no more space, you must delete an older image of the software before installing the new one.
NOTE: Starting in Junos OS release 20.3R1, ACX710 routers support limited images.
To upgrade the software on a router or switch: 1. Install the new software package using the request system software add command:
user@host> request system software add /var/tmp/installation-package

122
The variable installation-package is the name of the installation package. Specify the absolute path on the local disk, for example, for Junos OS Evolved, /var/tmp/junos-linux-install-ptx.iso. For package name prefixes, see "Junos OS and Junos OS Evolved Installation Packages Prefixes".
NOTE: (Does not apply to Junos OS Evolved) To install multiple software packages at one time, you can use the request system software add set command. For more information on this command, see the set option in "request system software add" on page 679.
CAUTION: Do not include the re0 | re1 option when you install a package using the request system software add command, if the Routing Engine on which the package is located and the Routing Engine on which you want to install the package are the same. In such cases, the package gets deleted after a successful upgrade. 2. Reboot the device to start the new software:
user@host> request system shutdown reboot Reboot the system ? [yes,no] (no) yes
NOTE: You must reboot the device to load the new software release on the device. To terminate the installation, do not reboot the device. Instead, finish the installation and then issue the request system software delete package-name command. This is your last chance to stop the installation.
The software is loaded when you reboot the system. Installation can take between 5 and 10 minutes. The device then reboots from the boot device on which the software was just installed. When the reboot is complete, the device displays the login prompt. While the software is being upgraded, the Routing Engine on which you are performing the installation does not route traffic. 3. Log in and verify the release of the software installed: · To verify release for installation of a Junos OS Evolved release, use the show system software list
command.
user@host> show system software list

123
· To verify release for installation of a Junos OS release, use the show version command.
user@host> show version
SEE ALSO request system software add | 679 show version
Installing the Software Package on a Device with Redundant Routing Engines
IN THIS SECTION Preparing the Device for the Installation | 123 Installing Software on the Backup Routing Engine | 125 Installing Software on the Remaining Routing Engine | 127 Finalizing the Installation | 130
If the device has two Routing Engines, perform a Junos OS installation on each Routing Engine separately to minimize disruption to network operation. To upgrade redundant Routing Engines, you first install the new Junos OS release on the backup Routing Engine while keeping the currently running software version on the primary Routing Engine. After making sure that the new software version is running correctly on the backup Routing Engine, you switch device control to the backup Routing Engine. Finally, you install the new software on the new backup Routing Engine. For detailed procedures, see the following subsections:
Preparing the Device for the Installation
Determine if this is the best procedure for upgrading your device: · If your EX8200 switch is running Junos OS Release 10.4R3 or later, you can upgrade the software
packages on both Routing Engines with a single command and with minimal network disruption by

124
using nonstop software upgrade (NSSU) instead of this procedure. See Upgrading Software on an EX6200 or EX8200 Standalone Switch Using Nonstop Software Upgrade (CLI Procedure).
· To upgrade two different Junos OS releases with no disruption on the control plane and with minimal disruption of traffic, you can use In-Service Software Upgrade, see Getting Started with Unified InService Software Upgrade for routers and switches, and Upgrading a Chassis Cluster Using In-Service Software Upgrade for SRX Series devices.
· To upgrade the software running on EX Series Ethernet Switches with redundant Routing Engines and all member switches in EX Series Virtual Chassis with a single command, you can use Nonstop Software Upgrade, see Understanding Nonstop Software Upgrade on EX Series Switches.
· To upgrade the software package on an EX6200 switch or an EX8200 switch with one installed Routing Engine, see "Installing Software on an EX Series Switch with a Virtual Chassis or Single Routing Engine (CLI Procedure)" on page 135.
WARNING: If graceful Routing Engine switchover (GRES) or nonstop active routing (NSR) is enabled when you initiate a software installation, the software does not install properly. Make sure you deactivate GRES (if it is enabled). By default, NSR is disabled. If NSR is enabled, remove the nonstop-routing statement from the [edit routing-options] hierarchy level to disable it.
To ensure GRES and NSR are disabled: 1. Log in to the primary Routing Engine's console.
For more information about logging in to the Routing Engine through the console port, see the specific hardware guide for your device.
2. From the CLI operational prompt, enter configuration mode:
{master} user@host> configure Entering configuration mode
{master} [edit] user@host#
3. Disable nonstop active routing (NSR) (supported on switches running Junos OS Release 10.4 or later):
{master}[edit] user@host# delete routing-options nonstop-routing

125
4. Disable nonstop-bridging if it is enabled:
{master}[edit] user@host# delete protocols layer2-control nonstop-bridging
5. Disable Routing Engine redundancy if enabled:
{master}[edit] user@host# (delete | deactivate) chassis redundancy graceful-switchover
6. Save the configuration change on both Routing Engines:
{master}[edit] user@host# commit synchronize re0: configuration check succeeds re1: commit complete re0: commit complete
NOTE: To ensure the most recent configuration changes are committed before the software upgrade, perform this step even if nonstop active routing and graceful Routing Engine switchover were previously disabled.
7. Exit the CLI configuration mode:
[edit] user@host# exit
Installing Software on the Backup Routing Engine
After the device has been prepared, you first install the new Junos OS release on the backup Routing Engine, while keeping the currently running software version on the primary Routing Engine. This enables the primary Routing Engine to continue operations, minimizing disruption to your network.

126
Before you start this procedure, decide which software package you need and download it to the /var/tmp directory of the primary Routing Engine. For information on which packages to use for which upgrades, see "Junos OS and Junos OS Evolved Installation Package Names" on page 69. To install software on the backup Routing Engine: 1. Log in to the console port on the current primary Routing Engine in slot 0. 2. Install the new software package on the backup Routing Engine (re1) using the request system
software add command:
user@host> request system software add re1 validate /var/tmp/jinstall-9.2R1.8­domestic-signed.tgz
Installation and validation take about 15 minutes.
CAUTION: Do not include the re0 or re1 option when you install a package using the request system software add command if the Routing Engine on which the package is located and the Routing Engine on which you want to install the package are the same. In such cases, the package gets deleted after a successful upgrade.
For M Series, MX Series, and T Series routers running Junos OS Release 12.2 and later, you can use the request system software add set command to install multiple software packages at the same time:
user@host> request system software add set re1 /var/tmp/installation-package
For more information about the request system software add set command, see "request system software add" on page 679 or the CLI Explorer. 3. Reboot the backup Routing Engine to start the new software:
user@host> request system reboot other-routing-engine Rebooting re1 user@host>
You must reboot the device to load the new installation of Junos OS on the device. You can combine steps 2 and 3 by adding reboot to the request system software add command. But if you do the steps separately, make sure you reboot the Routing Engine you just added system software to.

127
NOTE: To terminate the installation, do not reboot your device. Instead, finish the installation and then issue the request system software delete software-package-name command. This is your last chance to stop the installation.
All the software is loaded when you reboot the device. Installation can take between 5 and 10 minutes. The device then reboots from the boot device on which the software was just installed. When the reboot is complete, the device displays the login prompt. While the software is being upgraded, the Routing Engine on which you are performing the installation is not routing traffic.
4. Issue the show version invoke-on other-routing-engine command to verify the new software is installed.
user@host> show version invoke-on other-routing-engine re1: -------------------------------------------------------------------------Hostname: host1 Model: mx240 Junos: package-name . . . user@host>
5. (Optional) Add the jweb package using the request system software add command. Before you can add this package, you must first download the software as you did the installation package. For more information about downloading the jweb package, see "Downloading Software" on page 107. The jweb installation module adds a router management graphical user interface that you can use to view and configure your router.
Installing Software on the Remaining Routing Engine
Once the software is installed on the backup Routing Engine, you are ready to switch routing control to the backup Routing Engine, and then upgrade or downgrade the software on the remaining Routing Engine in slot 0. To install software on the primary Routing Engine: 1. Transfer routing control from the primary to the backup Routing Engine:
user@host> request chassis routing-engine master switch warning: Traffic will be interrupted while the PFE is re-initialized

128

Toggle mastership between routing engines ? [yes,no] (no) yes
Resolving mastership... Complete. The other routing engine becomes the master.
For more information about the request chassis routing-engine master command, see the CLI Explorer. 2. Verify that the Routing Engine in slot 1 is now the primary Routing Engine:

user@host> show chassis routing-engine

Routing Engine status: Slot 0: Current state Election priority

Backup Master (default)

Routing Engine status: Slot 1: Current state Election priority

Master Backup (default)

3. Install the new software package on the Routing Enigne in slot 0 using the request system software add command:

user@host> request system software add validate re0 /var/tmp/jinstall-9.2R1.8­domestic-signed.tgz Installation and validation take about 15 minutes.

CAUTION: Do not include the re0 or re1 option when you install a package using the request system software add command if the Routing Engine on which the package is located and the Routing Engine on which you want to install the package are the same. In such cases, the package gets deleted after a successful upgrade.

129
For M Series, MX Series, and T Series routers running Junos OS Release 12.2 and later, you can use the request system software add set command to install multiple software packages at the same time:
user@host> request system software add set re0 /var/tmp/installation-package
For more information about the request system software add set command, see "request system software add" on page 679 or the CLI Explorer. 4. Reboot the Routing Engine using the request system reboot command:
user@host> request system reboot Reboot the system? [yes, no] (no) yes
You must reboot the device to load the new installation of Junos OS on the device. You can combine steps 3 and 4 by adding reboot to the request system software add command. But if you do the steps separately, make sure you reboot the Routing Engine you just added system software to.
NOTE: To terminate the installation, do not reboot your device. Instead, finish the installation and then issue the request system software delete software-package-name command. This is your last chance to stop the installation.
The software is loaded when you reboot the system. Installation can take between 5 and 10 minutes. The device then reboots from the boot device on which the software was just installed. When the reboot is complete, the device displays the login prompt. While the software is being upgraded, the Routing Engine on which you are performing the installation does not route traffic. 5. Log in to the current backup Routing Engine (slot 0) and issue the show version command to verify the version of the software installed.
user@host> show version
6. (Optional) Add the jweb package using the request system software add command. Before you can add this package, you must first download the software as you did the installation package. For more information about downloading the jweb package, see "Downloading Software" on page 107. The jweb installation module adds a router management graphical user interface that you can use to view and configure your router.

130
Finalizing the Installation
Once the software is installed on both Routing Engines, you return the router back to its original configuration and back up the new installation. To finalize the redundant Routing Engines upgrade: 1. Restore the configuration that existed before you started this procedure (from "Preparing the Device
for the Installation"):
user@host> configure [edit] user@host# rollback 1
NOTE: The number on the rollback command should match the number of commits you did in preparing the router for the installation. For example, if you did a separate commit for disabling Routing Engine redundancy and disabling nonstop-bridging, you need to use rollback 2 in this step.
2. Save the configuration change on both Routing Engines:
[edit] user@host# commit synchronize and-quit
3. Transfer routing control back to the original primary Routing Engine in slot 0:
{backup} user@host> request chassis routing-engine master switch warning: Traffic will be interrupted while the PFE is re-initialized Toggle mastership between routing engines ? [yes,no] (no) yes Resolving mastership... Complete. The other routing engine becomes the master.
For more information about the request chassis routing-engine master command, see the CLI Explorer.

131

4. Verify that the Routing Engine (slot 0) is indeed the primary Routing Engine:

{master} user@host> show chassis routing-engine

Routing Engine status: Slot 0: Current state Election priority

Master Master (default)

Routing Engine status: Slot 1: Current state Election priority

Backup Backup (default)

5. After you have installed the new software and are satisfied that it is successfully running, back up the new software on both the primary and the backup Routing Engines.
· For backing up Junos OS with upgraded FreeBSD, use the request system snapshot recovery command. To find which platforms in which releases use Junos OS with upgraded FreeBSD, see Feature Explorer and enter Junos kernel upgrade to FreeBSD 10+. For more information, see Changes in Use of Snapshots for Junos OS with Upgraded FreeBSD.
· For Junos OS, use the request system snapshot command:

{master} user@host> request system snapshot {master} user@host> request routing-engine login other-routing-engine {backup} user@host-re1> request system snapshot {backup} user@host-re1> request routing-engine login other-routing-engine {master} user@host>
The root file system is backed up to /altroot, and /config is backed up to /altconfig. The root and / config file systems are on the router's CompactFlash card, and the /altroot and /altconfig file systems are on the router' s hard disk or solid-state drive (SSD).
For more information about the request system snapshot command, see the CLI Explorer .

132
NOTE: After you issue the request system snapshot command, you cannot return to the previous version of the software because the running copy and backup copy of the software are identical.
RELATED DOCUMENTATION Understanding Routing Engine Redundancy on Juniper Networks Routers Repartitioning Routing Engine System Storage to Increase the Swap Partition | 390
Installing Software on EX Series Switches
IN THIS SECTION Understanding Software Installation on EX Series Switches | 133 Installing Software on an EX Series Switch with a Virtual Chassis or Single Routing Engine (CLI Procedure) | 135 Installing Software on an EX Series Switch with Redundant Routing Engines (CLI Procedure) | 138 Upgrading the Loader Software on the Line Cards in a Standalone EX8200 Switch or an EX8200 Virtual Chassis | 145 Booting an EX Series Switch Using a Software Package Stored on a USB Flash Drive | 149
EX Series devices are delivered with pre-installed Junos operating system (Junos OS). Before you start this procedure, decide which software package you need and download it. For information on which packages to use for which upgrades, see "Junos OS and Junos OS Evolved Installation Package Names" on page 69.

133
Understanding Software Installation on EX Series Switches
IN THIS SECTION Overview of the Software Installation Process | 133 Installing Software on a Virtual Chassis | 134 Installing Software Using Automatic Software Download | 134 Autoinstalling a Configuration File on an EX2200 or EX3300 Switch from a Disk-on-Key USB Memory Stick | 134 Installing Software on an EX2300 or EX3400 Switch | 134
A Juniper Networks EX Series Ethernet Switch is delivered with the Juniper Networks Junos operating system (Junos OS) pre-installed. As new features and software fixes become available, you must upgrade your software to use them. You can also downgrade Junos OS to a previous release. This topic covers:
Overview of the Software Installation Process
An EX Series switch is delivered with a domestic version of Junos OS pre-installed. When you connect power to the switch, it starts (boots) from the installed software. You upgrade Junos OS on an EX Series switch by copying a software package to your switch or another system on your local network, then use either the J-Web interface or the command-line interface (CLI) to install the new software package on the switch. Finally, you reboot the switch; it boots from the upgraded software. After a successful upgrade, you should back up the new current configuration to a secondary device. You should following this procedure regardless of whether you are installing a domestic or controlled Junos OS package. During a successful upgrade, the upgrade package removes all files from /var/tmp and completely reinstalls the existing software. It retains configuration files, and similar information, such as secure shell and host keys, from the previous version. The previous software package is preserved in a separate disk partition, and you can manually revert back to it if necessary. If the software installation fails for any reason, such as loss of power during the installation process, the system returns to the originally active installation when you reboot.

134
Installing Software on a Virtual Chassis
You can connect individual EX Series switches together to form one unit and manage the unit as a single device, called a Virtual Chassis. The Virtual Chassis operates as a single network entity composed of member switches. Each member switch in a Virtual Chassis must be running the same version of Junos OS.
For ease of management, a Virtual Chassis provides flexible methods to upgrade software releases. You can deploy a new software release to all member switches of a Virtual Chassis or to only a particular member switch.
You can also upgrade the software on a Virtual Chassis using nonstop software upgrade (NSSU). NSSU takes advantage of graceful Routing Engine switchover (GRES) and nonstop active routing (NSR) to ensure no disruption to the control plane during the upgrade. You can minimize disruption to network traffic by defining link aggregation groups (LAGs) such that the member links of each LAG reside on different line cards or on different members. During an NSSU, the line cards and Virtual Chassis members are upgraded one at a time, so that traffic continues to flow through the other line cards or members while that line card or member is being upgraded.
Installing Software Using Automatic Software Download
The automatic software download feature uses the DHCP message exchange process to download and install software packages. Users can define a path to a software package on the DHCP server, and then the DHCP server communicates this path to EX Series switches acting as DHCP clients as part of the DHCP message exchange process. The DHCP clients that have been configured for automatic software download receive these messages and, when the software package name in the DHCP server message is different from that of the software package that booted the DHCP client switch, download and install the software package. See Upgrading Software by Using Automatic Software Download for Switches.
Autoinstalling a Configuration File on an EX2200 or EX3300 Switch from a Disk-onKey USB Memory Stick
You can use an autoinstallation process to configure the software on an EX2200 or EX3300 switch. You can use a configuration file that is in either text format or XML format. If you want to use an XMLformatted file, you use a Junos Space platform to create the configuration file. You place the configuration file on a Disk-on-Key USB memory stick.
Installing Software on an EX2300 or EX3400 Switch
Before installing software on an EX2300 or EX3400 switch:

135
· Ensure that at least 620 MB of disk space is available in the system before downloading the software installation package to the /var/tmp directory. Use the command show system storage to get details of the available space.
· If the space available is inadequate, use the command request system storage cleanup. Additionally, you can manually delete any other log or unwanted files from the /var/tmp or /var/log directories.
You can now follow the procedure in Installing Software on an EX Series Switch with a Virtual Chassis or Single Routing Engine (CLI Procedure) to complete the software installation.
NOTE: See the Knowledge Base for more information in regards to storage when upgrading Junos OS on EX2300 and EX3400 switches.
Installing Software on an EX Series Switch with a Virtual Chassis or Single Routing Engine (CLI Procedure)
You can use this procedure to upgrade Junos OS on a single routing engine in any EX Series switch, including all switches that do not support redundant Routing Engines. You can also use this procedure to upgrade software on all EX Series Virtual Chassis, with the exception of the EX8200 Virtual Chassis. This procedure can be used to upgrade the following switches or Virtual Chassis: · EX2200 switch · EX2300 switch · EX3200 switch · EX3300 switch · EX3400 switch · EX4200 switch · EX4300 switch · EX4500 switch · EX4550 switch · EX6200 switch (single Routing Engine upgrade only) · EX8200 switch (single Routing Engine upgrade only)

136
· All Virtual Chassis except EX8200 Virtual Chassis To upgrade software on an EX6200 or EX8200 switch running two Routing Engines, see Installing Software on an EX Series Switch with Redundant Routing Engines (CLI Procedure) or Upgrading Software on an EX6200 or EX8200 Standalone Switch Using Nonstop Software Upgrade (CLI Procedure). To upgrade software on an EX8200 Virtual Chassis, see Installing Software for All Devices in an EX8200 Virtual Chassis. To install software upgrades on a switch with a single Routing Engine: 1. Download the software package. 2. (Optional) Back up the current software configuration to a second storage option. See the Junos OS
Installation and Upgrade Guide for instructions on performing this task. 3. (Optional) Copy the software package to the switch. We recommend that you use FTP to copy the
file to the /var/tmp directory. This step is optional because Junos OS can also be upgraded when the software image is stored at a remote location. These instructions describe the software upgrade process for both scenarios. 4. Install the new package on the switch:
user@switch> request system software add package
NOTE: .On EX4300-MP devices, you must use the force-host option. For example, issue the request system software add source force-host command.
Replace package with one of the following paths: · For a software package in a local directory on the switch--/var/tmp/package.tgz. · For a software package on a remote server:
· ftp://hostname/pathname/package.tgz · http://hostname/pathname/package.tgz where package.tgz is, for example, jinstall-ex-4200-9.4R1.8-domestic-signed.tgz.
NOTE: Include the optional member option to install the software package on only one member of a Virtual Chassis:

137
user@switch> request system software add source member member-id
NOTE: On EX4300-MP devices, you must use the force-host option. For example, issue the request system software add source member member-id force-host command.
Other members of the Virtual Chassis are not affected. To install the software on all members of the Virtual Chassis, do not include the member option.
NOTE: To terminate the installation, do not reboot your device; instead, finish the installation and then issue the request system software delete package.tgz command, where package.tgz is, for example, jinstall-ex-4200-10.2R1.8-domestic-signed.tgz. This is your last chance to stop the installation. The request system software delete package.tgz command is not available on EX2300 and EX3400 switches.
5. Reboot to start the new software:
user@switch> request system reboot 6. After the reboot has completed, log in and verify that the new version of the software is properly
installed:
user@switch> show version 7. To ensure that the resilient dual-root partitions feature operates correctly, execute the following
command to copy the new Junos OS image into the alternate root partition:
user@switch> request system snapshot slice alternate To update the alternate root partitions on all members of a Virtual Chassis, use this command:
user@switch> request system snapshot slice alternate all-members Resilient dual-root partitions allow the switch to boot transparently from the alternate root partition if the system fails to boot from the primary root partition.

138
NOTE: EX2300 and EX3400 switches have two volumes: JUNOS volume and OAM (recovery) volume. To store a snapshot (non-recovery) on JUNOS volume, use the command request system snapshot. To create snapshot (recovery) on the OAM volume, use the command request system snapshot recovery.
Installing Software on an EX Series Switch with Redundant Routing Engines (CLI Procedure)
IN THIS SECTION Preparing the Switch for the Software Installation | 139 Installing Software on the Backup Routing Engine | 141 Installing Software on the Default Primary Routing Engine | 142 Returning Routing Control to the Default Primary Routing Engine (Optional) | 144
You can install software on a switch with redundant Routing Engines in one of two ways: · Perform an NSSU--An NSSU upgrades both Routing Engines with a single command and with a
minimum of network disruption. An NSSU takes advantage of GRES and NSR to ensure no disruption to the control plane. You can minimize disruption to network traffic by defining LAGs such that the member links of each LAG reside on different line cards. The line cards are upgraded one at a time, so that traffic continues to flow through the other line cards while a line card is being upgraded. You cannot use NSSU to downgrade the software running on a switch. For more information about NSSU, see Understanding Nonstop Software Upgrade on EX Series Switches. · Upgrade each Routing Engine manually--You can perform a Junos OS installation on each Routing Engine separately, starting with the backup Routing Engine. You can use this procedure to downgrade the software running on a switch. For an EX6200 switch or an EX8200 switch with redundant Routing Engines, you can minimize disruption to network operation during a Junos OS upgrade by upgrading the Routing Engines separately, starting with the backup Routing Engine.

139
NOTE: If your EX8200 switch is running Junos OS Release 10.4R3 or later, you can upgrade the software packages on both Routing Engines with a single command and with minimal network disruption by using nonstop software upgrade (NSSU) instead of this procedure. See Upgrading Software on an EX6200 or EX8200 Standalone Switch Using Nonstop Software Upgrade (CLI Procedure).
CAUTION: If graceful routing engine switchover (GRES) or nonstop active routing (NSR) is enabled when you initiate a software installation, the software does not install properly. Make sure you disable GRES before you begin the software installation by using the deactivate chassis redundancy graceful-switchover command in configuration mode. If GRES is enabled, it will be removed with the redundancy command. By default, NSR is disabled. If NSR is enabled, remove the nonstop-routing statement from the [edit routing-options] hierarchy level to disable it.
To upgrade the software package on an EX6200 switch or an EX8200 switch with one installed Routing Engine, see Installing Software on an EX Series Switch with a Virtual Chassis or Single Routing Engine (CLI Procedure). To upgrade redundant Routing Engines, you first install the new Junos OS release on the backup Routing Engine while keeping the currently running software version on the primary Routing Engine. After making sure that the new software version is running correctly on the backup Routing Engine, you switch device control to the backup Routing Engine. Finally, you install the new software on the new backup Routing Engine.
To upgrade Junos OS on the switch, perform the following tasks:
Preparing the Switch for the Software Installation
Perform the following steps before installing the software:
1. Log in to the primary Routing Engine's console. For information on logging in to the Routing Engine through the console port, see Connecting and Configuring an EX Series Switch (CLI Procedure).
2. Enter the Junos OS CLI configuration mode: a. Start the CLI from the shell prompt:
user@switch:RE% cli

140
You will see:
{master} user@switch> b. Enter configuration mode:
user@switch> configure
You will see:
{master}[edit] user@switch# 3. Disable nonstop active routing (NSR) (supported on switches running Junos OS Release 10.4 or later):
{master}[edit] user@switch# delete routing-options nonstop-routing 4. Disable nonstop bridging:
{master}[edit] user@switch# delete protocols layer2-control nonstop-bridging 5. Disable graceful Routing Engine switchover (GRES):
{master}[edit] user@switch# deactivate chassis redundancy graceful-switchover 6. Save the configuration change on both Routing Engines:
{master}[edit] user@switch# commit synchronize

141
NOTE: To ensure the most recent configuration changes are committed before the software upgrade, perform this step even if nonstop active routing and graceful Routing Engine switchover were previously disabled.
7. Exit the CLI configuration mode:
[edit] user@switch# exit
8. (Optional) Back up the current software configuration to a second storage option. See the Junos OS Installation and Upgrade Guide for instructions on performing this task.
Installing Software on the Backup Routing Engine
After you have prepared the switch for software installation, install the software on the backup Routing Engine. During the installation, the primary Routing Engine continues operations, minimizing the disruption to network traffic. 1. Download the software. 2. Copy the software package to the switch. We recommend that you use FTP to copy the file to
the /var/tmp directory. 3. Log in to the console of the backup Routing Engine. 4. Install the new software package:
user@switch> request system software add /var/tmp/package.tgz
where package.tgz is, for example, jinstall-ex-8200-10.2R1.8-domestic-signed.tgz.
NOTE: To terminate the installation, do not reboot your device; instead, finish the installation and then issue the request system software delete package.tgz command, where package.tgz is, for example, jinstall-ex-8200-10.2R1.8-domestic-signed.tgz. This is your last chance to stop the installation.
5. Reboot to start the new software:
user@switch> request system reboot Reboot the system? [yes, no] (no) yes

142

NOTE: You must reboot the switch to load the new installation of the Junos OS.
6. After the reboot has completed, log in and verify the new version of the software is properly installed:
user@switch> show version
Installing Software on the Default Primary Routing Engine
To transfer control to the backup Routing Engine and then upgrade or downgrade the primary Routing Engine software: 1. Log in to the primary Routing Engine console port. 2. Transfer control to the backup Routing Engine:
CAUTION: Because graceful Routing Engine switchover is disabled, this switchover causes all line cards in the switch to reload. All network traffic passing through these line cards is lost during the line card reloads.
user@switch> request chassis routing-engine master switch 3. Verify that the default backup Routing Engine (shown as slot 1 in the command output) is now the
primary Routing Engine:
user@switch> show chassis routing-engine You will see:

Routing Engine status: Slot 0: Current state Election priority
Routing Engine status: Slot 1:

Backup Master (default)

143

Current state Election priority
4. Install the new software package:

Master Backup (default)

user@switch> request system software add package.tgz 5. Reboot the Routing Engine:

user@switch> request system reboot Reboot the system? [yes, no] (no) yes
When the reboot completes, the prompt will reappear. Wait for this prompt to reappear before proceeding to the next step. 6. Log in to the default backup Routing Engine (slot 1) through the console port. 7. Re-enable graceful Routing Engine switchover:

[edit] user@switch# activate chassis redundancy graceful-switchover
Re-enabling graceful Routing Engine switchover allows any future Routing Engine switchovers to occur without loss of any network traffic. 8. Re-enable nonstop active routing:

[edit] user@switch# set routing-options nonstop-routing

NOTE: Automatic commit synchronization is a requirement for nonstop active routing. If you have not yet enabled it, do so with the set system commit synchronize command.
9. Save the configuration change:
[edit] user@switch# commit synchronize

144
10. To ensure that the resilient dual-root partitions feature operates correctly, execute the following command to copy the new Junos OS image into the alternate root partition on each Routing Engine:
user@switch> request system snapshot slice alternate routing-engine both
Resilient dual-root partitions allow the switch to boot transparently from the alternate root partition if the system fails to boot from the primary root partition. If you want to return routing control to the Routing Engine that was the primary Routing Engine at the beginning of the procedure (the default primary Routing Engine), perform the next task.
Returning Routing Control to the Default Primary Routing Engine (Optional)
The switch can maintain normal operations with the Routing Engine in slot 1 acting as the primary Routing Engine after the software upgrade, so only perform this task if you want to return routing control to the default primary Routing Engine in slot 0. 1. Transfer routing control back to the default primary Routing Engine:
user@switch> request chassis routing-engine master switch 2. Verify that the default primary Routing Engine (slot 0) is indeed the primary Routing Engine:
user@switch> show chassis routing-engine
You will see:

Routing Engine status: Slot 0: Current state Election priority
Routing Engine status: Slot 1: Current state Election priority

Master Master (default)
Backup Backup (default)

145

Upgrading the Loader Software on the Line Cards in a Standalone EX8200 Switch or an EX8200 Virtual Chassis
You are almost never required to upgrade the loader software on the line cards in an EX8200 switch.
Upgrading the loader software version for a line card is not a requirement to complete any software upgrade. In rare cases, a line card might go offline immediately after a software upgrade because the loader software version on the line card requires an upgrade to become compatible with the upgraded Junos OS. You can upgrade the loader software on the line cards as a best practice to avoid this problem and other less severe issues.
The loader software on any line card in an EX8200 switch is updated using the same loader software package that upgrades the EX8200 Routing Engine loader software. The line card software loader contains two banks, each with a single loader software version. This procedure is used to upgrade the loader software for both banks of a line card in a standalone EX8200 switch or an EX8200 Virtual Chassis.
To upgrade the loader software on the line cards in a standalone EX8200 switch or an EX8200 Virtual Chassis:
NOTE: If you are upgrading Junos OS, the Routing Engine loader software, and the line card loader software, we recommend that you upgrade in this order: Junos OS, line card loader software, Routing Engine loader software.

1. Determine the version of the loader software for the line cards:

user@switch> show chassis firmware

Part FPC 6 FPC 7 Routing Engine 0 Routing Engine 1

Type U-Boot loader U-Boot loader U-Boot loader U-Boot loader

Version U-Boot 1.1.6 (Jan 13 2009 - 06:55:22) 2.3.0 FreeBSD/PowerPC U-Boot bootstrap loader 2.2 U-Boot 1.1.6 (Jan 13 2009 - 06:55:22) 2.3.0 FreeBSD/PowerPC U-Boot bootstrap loader 2.2 U-Boot 1.1.6 (Mar 11 2011 - 04:29:01) 3.5.0 FreeBSD/PowerPC U-Boot bootstrap loader 2.4 U-Boot 1.1.6 (Mar 11 2011 - 04:29:01) 2.3.0 FreeBSD/PowerPC U-Boot bootstrap loader 2.4

146
NOTE: On an EX8200 Virtual Chassis, you cannot issue the show chassis firmware command on the primary external Routing Engine. You must issue this command on each member switch.
a. From the primary external Routing Engine, start a shell session on the member switch, for example:
user@external-routing-engine> request session member 0
b. Enter the CLI and issue the show chassis firmware command. c. Repeat these steps for the other member switch. The loader software version appears after the timestamp (see the Version column in the output) for each component. For example, In the example given in this step, look at the first FPC listed (FPC 6). Ignore the U-Boot version number (1.1.6) and find the loader software version number (2.3.0) after the timestamp (U-Boot 1.1.6 (Jan 13 2009 - 06:55:22). The U-Boot version number has nothing to do with the loader software version that you need to determine. If the loader software version is earlier than 3.5.0 for any FPC, you should consider upgrading the loader software for that line card. 2. Download the loader software package from the Juniper Networks Download page (https:// support-www.juniper.net/support/downloads/) and place the software package on an internal software distribution site or in a local directory on the switch. We recommend using /var/tmp as the local directory on the switch.
NOTE: To obtain the loader software package, see the Download Software page at https:// support-www.juniper.net/support/downloads/. Select the OS type and the release. Then find and click the download image.
A login screen appears. 3. Log in with your user name and password.

147
4. Disable graceful Routing Engine switchover (GRES) and nonstop active routing (NSR), if enabled. Commit the configuration:
user@switch# deactivate chassis redundancy graceful-switchover user@switch# deactivate routing-options nonstop-routing user@switch# commit synchronize
5. Install the loader package:
user@switch> request system software add package
Replace package with one of the following paths: · For a software package in the /var/tmp directory on the switch or external Routing Engine
--/var/tmp/package.tgz. · For a software package on a remote server:
· ftp://hostname/pathname/package.tgz · http://hostname/pathname/package.tgz In the above options, package.tgz might be, for example, jloader-ex-8200-11.3build-signed.tgz. 6. Upgrade the loader software. · To upgrade the loader software for a line card on a standalone EX8200 switch:
user@switch> request system firmware upgrade fpc slot slot-number Firmware upgrade initiated.... Please wait for ~2mins for upgrade to complete....
· To upgrade the loader software for a line card on an EX8200 member switch in an EX8200 Virtual Chassis:
user@switch> request system firmware upgrade fpc slot slot-number member member-id Firmware upgrade initiated.... Please wait for ~2mins for upgrade to complete....

148

7. Confirm the loader software upgrade:

user@switch> show system firmware

Part

Type

FPC 6

U-Boot

FPC 7

U-Boot

Routing Engine 0 RE BIOS

Routing Engine 1

Tag Current version
0 2.3.0 0 2.3.0 0 3.1.1 0 3.1.1

Available Status version
UPGRADED SUCCESSFULLY OK OK OK

The status is UPGRADED SUCCESSFULLY if the boot loader version update process is complete.
The status is PROGRAMMING if the boot loader version update process is still in progress.
Do not proceed to the next step until the show system firmware output confirms that the loader software upgrade is complete. 8. Restart the line card. · To restart a line card on a standalone EX8200 switch:

user@switch> request chassis fpc restart slot slot-number · To restart a line card on an EX8200 member switch in an EX8200 Virtual Chassis:

user@switch> request chassis fpc restart slot slot-number member member-id

NOTE: You can monitor the status of the line card restart by using the show chassis fpc command.
9. After the line card restart has completed, confirm the loader software version update:

user@switch> show chassis firmware

Part

Type

FPC 6

U-Boot

FPC 7

U-Boot

Routing Engine 0 RE BIOS

Routing Engine 1

Tag Current version
0 3.5.0 0 2.3.0 0 3.1.1 0 3.1.1

Available Status version
OK OK OK OK

149
The current version has updated to 3.5.0. You have upgraded the loader software for one bank of the line card. 10. Repeat Steps 4 through 7 to upgrade the loader software on the other bank of the line card.
NOTE: A bank switchover occurs automatically as part of the line card restart. Repeating Steps 3 through 6 updates the loader software on the other bank.
11. Repeat Steps 4 through 8 for all other line cards that require a line card loader version upgrade.
SEE ALSO Upgrading Software on an EX6200 or EX8200 Standalone Switch Using Nonstop Software Upgrade (CLI Procedure) Upgrading Software on an EX8200 Virtual Chassis Using Nonstop Software Upgrade (CLI Procedure) Troubleshooting an EX8200 Line Card's Failure to Power On
Booting an EX Series Switch Using a Software Package Stored on a USB Flash Drive
There are two methods of getting Junos OS stored on a USB flash drive before using the software to boot the switch. You can pre-install the software onto the USB flash drive before inserting the USB flash drive into the USB port, or you can use the system snapshot feature to copy files from internal switch memory to the USB flash drive. To move files into USB flash memory by using a system snapshot and use those files to boot the switch, see "Creating a Snapshot and Using It to Boot an EX Series Switch" on page 14. We recommend that you use this method to boot the switch from a USB flash drive if your switch is running properly. If you need to pre-install the software onto the USB flash drive, you can use the method described in this topic. Pre-installing Junos OS onto a USB flash drive to boot the switch can be done at any time and is particularly useful when the switch boots to the loader prompt because the switch cannot locate the Junos OS in internal flash memory. Ensure that you have the following tools and parts available to boot the switch from a USB flash drive: · A USB flash drive that meets the EX Series switch USB port specifications. See USB Port
Specifications for an EX Series Switch. · A computer or other device that you can use to download the software package from the Internet
and copy it to the USB flash drive.

150
To download a Junos OS package onto a USB flash drive before inserting the USB flash drive: 1. Download the Junos OS package that you want to place onto the EX Series switch from the Internet
onto the USB flash drive by using your computer or other device. 2. Remove the USB flash drive from the computer or other device. 3. Insert the USB flash drive into the USB port on the switch. 4. This step can be performed only when the prompt for the loader script (loader>) is displayed. The
loader script starts when the Junos OS loads but the CLI is not working for any reason or if the switch has no software installed. Install the software package onto the switch:
loader> install source
where source represents the name and location of the Junos OS package on the USB flash drive. The Junos OS package on a flash drive is commonly stored in the root drive as the only file--for example, file:///jinstall-ex-4200-9.4R1.5-domestic-signed.tgz.
SEE ALSO EX4300 Switches Hardware Overview Switch Fabric and Routing Engine (SRE) Module in an EX6200 Switch Switch Fabric and Routing Engine (SRE) Module in an EX8208 Switch Routing Engine (RE) Module in an EX8216 Switch
RELATED DOCUMENTATION Upgrading Software on an EX6200 or EX8200 Standalone Switch Using Nonstop Software Upgrade (CLI Procedure) Troubleshooting Software Installation on EX Series Switches | 521

151
Installing Software on QFX Series Devices
IN THIS SECTION Installing Software Packages on QFX Series Devices | 151 Upgrading Software by Using Automatic Software Download for Switches | 165 Upgrading Jloader Software on QFX Series Devices | 168 Installing Junos OS Software with Junos Automation Enhancements | 183
QFX Series devices are delivered with the Junos operating system (Junos OS) preinstalled. Before you start this procedure, decide which software package you need and download it. For information on which packages to use for which upgrades, see "Junos OS and Junos OS Evolved Installation Package Names" on page 69.
Installing Software Packages on QFX Series Devices
IN THIS SECTION Installing the Software on QFX10002-60C Switches | 152 Installing a Standard Software Package on QFX5000 and EX4600 Switches | 153 Installing a Standard Software Package on QFX10002 Switches | 154 Upgrading Software from Junos OS Release 15.1X53-D3X to Junos OS Release 15.1X53-D60, 15.1X53-D61.7, 15.1X53-D62, and 15.1X53-D63 on QFX10008 and QFX10016 Switches | 157 Installing a Software Package on QFX10008 and QFX10016 Switches | 161
We recommend that you connect to the console port while installing the installation package so you can respond to any required user input and detect any errors that may occur. Before you install the new installation package, back up your current configuration files because the upgrade process removes all of the stored files on the switch.

152
To back up your current configuration files, enter the save command:
user@switch# save filename
Executing this command saves a copy of your configuration files to a remote location such as an external USB device. Installation procedures are in the following subsections:
Installing the Software on QFX10002-60C Switches
This section explains how to upgrade the software, which includes both the host OS and the Junos OS. This upgrade requires that you use a VM host package--for example, a junos-vmhost-install-x.tgz . During a software upgrade, the alternate partition of the SSD is upgraded, which will become primary partition after a reboot. If there is a boot failure on the primary SSD, the switch can boot using the snapshot available on the alternate SSD.
NOTE: The QFX10002-60C switch supports only the 64-bit version of Junos OS.
NOTE: If you have important files in directories other than /config and /var, copy the files to a secure location before upgrading. The files under /config and /var (except /var/etc) are preserved after the upgrade.
To upgrade the software, you can use the following methods: 1. If the installation package resides locally on the switch, issue the request vmhost software add
<pathname><source> command. For example:
user@switch> request vmhost software add /var/tmp/junos-vmhost-install-qfx-x86-64-18.1R1.9.tgz
If the Install Package resides remotely from the switch, issue the request vmhost software add <pathname><source> command.

153
For example:
user@switch> request vmhost software add ftp://ftpserver/directory/junos-vmhost-install-qfxx86-64-18.1R1.9.tgz 2. After the reboot has finished, verify that the new version of software has been properly installed by issuing the show version command.
user@switch> show version
Installing a Standard Software Package on QFX5000 and EX4600 Switches
NOTE: Before you install the software, back up any critical files in /var/home. For more information regarding how to back up critical files, contact Customer Support at https:// www.juniper.net/support.
NOTE: On QFX5100 and EX4600 switches, the Host OS is not upgraded automatically, so you must use the force-host option if you want the Junos OS and Host OS versions to be the same. However, pay attention to these notes regarding Junos OS and Host OS versions: · The Junos OS and Host OS versions do not need to be the same. · During an ISSU, the Host OS cannot be upgraded. · Upgrading the Host OS is not required for every software upgrade, as noted above. If you are downgrading from Junos OS Release 14.1X53-D40 to any release earlier than 14.1X53-D40, you must use the force-host option or else the switch will issue core dumps.
NOTE: QFX5100 and EX4600 standalone SKUs, for all Junos OS releases, support software images with a package filename in the format yyy-qfx-5-zzz (non-TVP architecture). They do not support software images with a package filename in the format yyy-qfx-5e-zzz (TVP architecture).
1. If the installation package resides locally on the switch, issue the request system software add <pathname><source> reboot command.

154
For example:
user@switch> request system software add /var/tmp/jinstall-host-qfx-5-17.2R1.n-signed.tgz reboot
If the Install Package resides remotely, issue the request system software add <pathname><source> reboot command. For example:
user@switch> request system software add ftp://ftpserver/directory/jinstall-host-qfx-5-17.2R1.nsigned.tgz reboot 2. After the reboot has finished, verify that the new version of software has been properly installed by executing the show version command.
user@switch> show version
Installing a Standard Software Package on QFX10002 Switches
NOTE: Before you install the software, back up any critical files in /var/home. For more information regarding how to back up critical files, contact Customer Support at https:// www.juniper.net/support.
NOTE: If you want to downgrade from Junos OS Release 15.1X53-D60 to a previous release, pay attention to these caveats:

155

Table 6: Caveats for Downgrading from Junos OS Release 15.1X53-D60 to Previous Software Releases

Junos OS Software Releases

Using the CLI

Using a USB Stick

15.1X53-D33

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.

15.1X53-D32

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.

NOTE: You must downgrade to Junos OS Release 15.1X53D33 before you downgrade to Junos OS Release 15.1X53D30.

NOTE: You must downgrade to Junos OS Release 15.1X53-D33 before you downgrade to Junos OS Release 15.1X53-D32.

156

Table 6: Caveats for Downgrading from Junos OS Release 15.1X53-D60 to Previous Software Releases (Continued)

Junos OS Software Releases

Using the CLI

Using a USB Stick

15.1X53-D30

No

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.
NOTE: You must downgrade to Junos OS Release 15.1X53-D33 before you downgrade to Junos OS Release 15.1X53-D30.

Releases prior to 15.1X53-D30 No

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.
NOTE: You must downgrade to Junos OS Release 15.1X53-D33 before you downgrade to Junos OS Release 15.1X53-D30.

Install the software in one of two ways:
1. · If the installation package resides locally on the switch, issue the request system software add <pathname><source> reboot command.

157
For example:
user@switch> request system software add /var/tmp/jinstall-host-qfx-10-17.2R1.n-securesigned.tgz reboot
· If the Install Package resides remotely, issue the request system software add <pathname><source> reboot command. For example:
user@switch> request system software add ftp://ftpserver/directory/jinstall-host-qfx-10-17.2R1.nsecure-signed.tgz reboot 2. After the reboot has finished, verify that the new version of software has been properly installed by issuing the show version command.
user@switch> show version
Upgrading Software from Junos OS Release 15.1X53-D3X to Junos OS Release 15.1X53-D60, 15.1X53-D61.7, 15.1X53-D62, and 15.1X53-D63 on QFX10008 and QFX10016 Switches
NOTE: Before you install the software, back up any critical files in /var/home. For more information regarding how to back up critical files, contact Customer Support at https:// www.juniper.net/support.
NOTE: If you want to downgrade from Junos OS Release 15.1X53-D60 to a previous release, pay attention to these caveats:

158

Table 7: Caveats for Downgrading from Junos OS Release 15.1X53-D60 to Previous Software Releases

Junos OS Software Releases

Using the CLI

Using a USB Stick

15.1X53-D33

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.

15.1X53-D32

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.

NOTE: You must downgrade to Junos OS Release 15.1X53D33 before you downgrade to Junos OS Release 15.1X53D30.

NOTE: You must downgrade to Junos OS Release 15.1X53-D33 before you downgrade to Junos OS Release 15.1X53-D32.

159

Table 7: Caveats for Downgrading from Junos OS Release 15.1X53-D60 to Previous Software Releases (Continued)

Junos OS Software Releases

Using the CLI

Using a USB Stick

15.1X53-D30

No

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.
NOTE: You must downgrade to Junos OS Release 15.1X53-D33 before you downgrade to Junos OS Release 15.1X53-D30.

Releases prior to 15.1X53-D30 No

Yes, but the configuration is lost, and there is no workaround. We recommend that you save the configuration to an external location, such as a remote server, and then load the configuration after you have successfully downgraded.
NOTE: You must downgrade to Junos OS Release 15.1X53-D33 before you downgrade to Junos OS Release 15.1X53-D30.

The switch contains two routing engines, so you will need to install the software on each routing engine (re0 and re1).
1. To install the software on re0:

160
If the installation package resides locally on the switch, issue the request system software add <pathname><source> command.
user@switch> request system software add /var/tmp/jinstall-host-qfx-10-m-15.1X53-D60.4-securedomestic-signed.tgz re0
If the Install Package resides remotely from the switch, issue the request system software add <pathname><source> re0 command. For example:
user@switch> request system software add ftp://ftpserver/directory/jinstall-host-qfx-10-m-15.1X53D60.4-secure-domestic-signed.tgz re0 2. To install the software on re1: If the installation package resides locally on the switch, issue the request system software add
<pathname><source> command.
user@switch> request system software add /var/tmp/jinstall-host-qfx-10-m-15.1X53-D60.4-securedomestic-signed.tgz re1
If the Install Package resides remotely from the switch, issue the request system software add <pathname><source> re1 command. For example:
user@switch> request system software add ftp://ftpserver/directory/jinstall-host-qfx-10-m-15.1X53D60.4-secure-domestic-signed.tgz re1 3. Reboot both routing engines. For example:
user@switch> request system reboot both-routing-engines 4. After the reboot has finished, verify that the new version of software has been properly installed by
executing the show version command.
user@switch> show version

161
Installing a Software Package on QFX10008 and QFX10016 Switches
IN THIS SECTION Preparing the Switch for Installation | 161 Installing Software on the Backup Routing Engine | 162 Installing Software on the Primary Routing Engine | 163
Because the switch has two Routing Engines, perform a Junos OS installation on each Routing Engine separately to avoid disrupting network operation.
NOTE: Before you install the software, back up any critical files in /var/home. For more information regarding how to back up critical files, contact Customer Support at https:// www.juniper.net/support.
CAUTION: If graceful Routing Engine switchover (GRES), nonstop bridging (NSB), or nonstop active routing (NSR) is enabled when you initiate a software installation, the software does not install properly. Make sure you issue the CLI delete chassis redundancy command when prompted. If GRES is enabled, it will be removed with the redundancy command. By default, NSR is disabled. If NSR is enabled, remove the nonstop-routing statement from the [edit routing-options] hierarchy level to disable it.
To upgrade the software, perform the following tasks:
Preparing the Switch for Installation Perform the following steps before installing the software: 1. Log in to the primary Routing Engine's console.
For more information about logging in to the Routing Engine through the console port, see the specific hardware guide for your switch. 2. From the command line, enter configuration mode:
user@switch> configure

162
3. Disable Routing Engine redundancy:
user@switch# delete chassis redundancy
4. Disable nonstop-bridging:
user@switch# delete protocols layer2-control nonstop-bridging
5. Save the configuration change on both Routing Engines:
user@switch# commit synchronize
6. Exit the CLI configuration mode:
user@switch# exit
Installing Software on the Backup Routing Engine After the switch has been prepared, you first install the new Junos OS release on the backup Routing Engine, while keeping the currently running software version on the primary Routing Engine. This enables the primary Routing Engine to continue operations, minimizing disruption to your network. After making sure that the new software version is running correctly on the backup Routing Engine, you are ready to switch routing control to the backup Routing Engine, and then upgrade or downgrade the software version on the other Routing Engine. 1. Log in to the console port on the other Routing Engine (currently the backup).
For more information about logging in to the Routing Engine through the console port, see the specific hardware guide for your switch. 2. Install the new software package using the request system software add command:
user@switch> request system software add validate /var/tmp/jinstall-host-qfx-10-17.2R1.n-securesigned.tgz For more information about the request system software add command, see the CLI Explorer.

163
3. Reboot the switch to start the new software using the request system reboot command:
user@switch> request system reboot
NOTE: You must reboot the switch to load the new installation of Junos OS on the switch. To terminate the installation, do not reboot your switch. Instead, finish the installation and then issue the request system software delete <package-name> command. This is your last chance to stop the installation.
All the software is loaded when you reboot the switch. Installation can take between 5 and 10 minutes. The switch then reboots from the boot device on which the software was just installed. When the reboot is complete, the switch displays the login prompt. While the software is being upgraded, the Routing Engine on which you are performing the installation is not sending traffic. 4. Log in and issue the show version command to verify the version of the software installed.
user@switch> show version
Installing Software on the Primary Routing Engine Once the software is installed on the backup Routing Engine, you are ready to switch routing control to the backup Routing Engine, and then upgrade or downgrade the primary Routing Engine software: 1. Log in to the primary Routing Engine console port.
For more information about logging in to the Routing Engine through the console port, see the specific hardware guide for your switch. 2. Transfer routing control to the backup Routing Engine:
user@switch> request chassis routing-engine master switch
For more information about the request chassis routing-engine master command, see the CLI Explorer.

164

3. Verify that the backup Routing Engine (slot 1) is the primary Routing Engine:

user@switch> show chassis routing-engine

Routing Engine status:

Slot 0:

Current state

Backup

Election priority

Master (default)

Routing Engine status: Slot 1: Current state Election priority

Master Backup (default)

4. Install the new software package using the request system software add command:

user@switch> request system software add validate /var/tmp/jinstall-host-qfx-10-17.2R1.n-securesigned.tgz
For more information about the request system software add command, see the CLI Explorer. 5. Reboot the Routing Engine using the request system reboot command:

user@switch> request system reboot

NOTE: You must reboot to load the new installation of Junos OS on the switch. To terminate the installation, do not reboot your system. Instead, finish the installation and then issue the request system software delete jinstall <package-name> command. This is your last chance to stop the installation.
The software is loaded when you reboot the system. Installation can take between 5 and 10 minutes. The switch then reboots from the boot device on which the software was just installed. When the reboot is complete, the switch displays the login prompt.
While the software is being upgraded, the Routing Engine on which you are performing the installation does not send traffic.
6. Log in and issue the show version command to verify the version of the software installed.

165

7. Transfer routing control back to the primary Routing Engine:

user@switch> request chassis routing-engine master switch
For more information about the request chassis routing-engine master command, see the CLI Explorer. 8. Verify that the primary Routing Engine (slot 0) is indeed the primary Routing Engine:

user@switch> show chassis routing-engine

Routing Engine status:

Slot 0:

Current state

Master

Election priority

Master (default)

outing Engine status: Slot 1: Current state Election priority

Backup Backup (default)

Upgrading Software by Using Automatic Software Download for Switches
IN THIS SECTION Configuring DHCP Services for the Switch | 166 Enabling Automatic Software Download on a Switch | 166 Verifying That Automatic Software Download Is Working Correctly | 167

The automatic software download feature uses the Dynamic Host Configuration Protocol (DHCP) message exchange process to download and install software packages. You configure the automatic software download feature on switches that act as DHCP clients. You must enable automatic software download on a switch before the software upgrade can occur.

166
You configure a path to a software package file on the DHCP server. The server communicates the path to the software package file through DHCP server messages. If you enable automatic software download, the DHCP client switch compares the software package name in the DHCP server message with the name of the software package that booted the switch. If the software packages are different, the DHCP client switch downloads and installs the software package specified in the DHCP server message. Complete the following tasks in order:
Configuring DHCP Services for the Switch
Before you upgrade software by using automatic software download, ensure that you have configured DHCP services for the switch, including configuring a path to a boot server and a boot file. To configure a path to a boot server and a boot file: 1. Configure the name of the boot server advertised to DHCP clients. The client uses a boot file located
on the boot server to complete DHCP setup. This configuration is equivalent to DHCP option 66:
[edit system services dhcp] user@switch# set boot-server (address | hostname)
2. Set the boot file advertised to DHCP clients. After the client receives an IP address and the boot file location from the DHCP server, the client uses the boot image stored in the boot file to complete the DHCP setup. This configuration is equivalent to DHCP option 67:
[edit system services dhcp] user@switch# set boot-file filename
Enabling Automatic Software Download on a Switch
To enable automatic software download on a switch that acts as a DHCP client:
[edit chassis] user@switch# set auto-image-upgrade
After automatic software download is enabled on your DHCP client switch and after DHCP services are enabled on your network, an automatic software download can occur at any time as part of the DHCP message exchange process.

167
If an automatic software download occurs, you see the following message on the switch:
Auto-image upgrade started On successful installation system will reboot automatically The switch reboots automatically to complete the upgrade.
Verifying That Automatic Software Download Is Working Correctly
IN THIS SECTION Purpose | 167 Action | 167 Meaning | 168

Purpose Verify that the automatic software download feature is working correctly.
Action Use the show system services dhcp client interface-name command to verify that the automatic software download feature has been used to install a software package.

user@switch> show system services dhcp client ge-0/0/1.0

Logical Interface Name

ge-0/0/1.0

Hardware address

00:0a:12:00:12:12

Client Status

bound

Vendor Identifier

ether

Server Address

10.1.1.1

Address obtained

10.1.1.89

Lease Obtained at

2009-08-20 18:13:04 PST

Lease Expires at

2009-08-22 18:13:04 PST

DHCP Options : Name: name-server, Value: [ 10.209.194.131, 203.0.113.2,
203.0.113.3 ] Name: server-identifier, Value: 10.1.1.1

168
Name: router, Value: [ 10.1.1.80 ] Name: boot-image, Value: jinstall-ex-4200-9.6R1.5-domestic-signed.tgz Name: boot-image-location, Value: 10.1.1.25:/bootfiles/
Meaning The output from this command shows the name and location of the software package under DHCP options when automatic software download was last used to install a software package. The sample output in DHCP options shows that the last DHCP server message to arrive on the DHCP client had a boot server address of 10.1.1.1 and a boot file named jinstall-ex-4200-9.6R1.5-domestic-signed.tgz. If automatic software download was enabled on this client switch during the last DHCP message exchange, these values were used by the switch to upgrade the software.
RELATED DOCUMENTATION Configuring a DHCP Server on Switches
Upgrading Jloader Software on QFX Series Devices
IN THIS SECTION Jloader Software Version 1.1.4 Guidelines | 171 Upgrading Jloader Software on a QFX3500 Switch | 171 Upgrading Jloader Software on a QFabric System | 174
Jloader software contains a boot loader (Uboot), which is used to bring up QFX Series devices and load the Junos OS from the flash memory of these devices. You can upgrade Jloader software on QFX3500 switches, QFX3500 and QFX3600 Node devices, and QFX3600-I and QFX3008-I Interconnect devices.

169

NOTE: Before you upgrade the Jloader software, see Table 8 on page 169, Table 9 on page 170, and Table 10 on page 170 to make sure that you are upgrading to the right version of Jloader software for the Junos OS software release running on your QFX3500 switches, or Node devices and Interconnect devices in your QFabric system.

See Table 11 on page 170 to see which Uboot software versions are available and the filenames of the Jloader software packages.
Table 8: Junos OS and Jloader Software Compatibility Matrix for the QFX3500 Switch and QFX3500 Node Device

Junos OS Software Version

1.1.2

1.1.4

1.1.5

1.1.8

11.3R1 and later (QFX3500 switch)

Supported Supported Not supported Supported and recommended

11.3X30.6 and later (QFX3500 Node device)

Supported Supported Not supported Supported and recommended

12.1X49-D1 and later (QFX3500 switch)

Supported Supported Not supported Supported and recommended

12.2X50-D1 and later (QFX3500 switch and QFX3500 Node device)

Supported

Supported Not supported

Supported and recommended

NOTE: An en dash means that the item is not applicable.

170

Table 9: Junos OS and Jloader Software Compatibility Matrix for the QFX3008-I Interconnect Device

Junos OS Software Version

1.1.2

1.1.4

1.1.5

1.1.8

11.3X30.9 and later (QFX3008-I Interconnect device)

Supported Supported Not supported Supported and recommended

11.3X30.6 and later (QFX3008-I Interconnect device)

Supported Supported Not supported Supported and recommended

12.2X50-D10.3 and later

Supported Supported Not supported Supported and

(QFX3008-I Interconnect device)

recommended

NOTE: An en dash means that the item is not applicable.

Table 10: Junos OS and Jloader Software Compatibility Matrix for the QFX3600-I Interconnect Device and QFX3600 Node Device

Junos OS Software Version

1.1.2 1.1.4 1.1.5

1.1.8

12.2X50-D10.3 and later (QFX3600-I Interconnect Device and QFX3600 Node Device)

-

-

Supported Supported and

recommended

12.2X50-D20 and later (QFX3600 switch)

-

-

Supported Supported and

recommended

Table 11: Uboot Software Release and Jloader Software Compatibility Matrix

Uboot Software Release Number

Jloader Software Package Name

1.1.2

jloader-qfx-11.3X30.9-signed.tgz

171

Table 11: Uboot Software Release and Jloader Software Compatibility Matrix (Continued)

Uboot Software Release Number

Jloader Software Package Name

1.1.4 (11.3R3 and 11.3R2 releases only. Not supported on 11.3R1)

jloader-qfx-11.3I20120127_0733_dc-builder-signed.tgz

1.1.4 (12.1R1 release and later)

jloader-qfx-12.1-20120125_pr.0-signed.tgz

1.1.5 (12.2X50-D10.3 and later)

jloader-qfx-12.2X50.D10.3-signed.tgz

1.1.8 (13.1X50-D15.1 and later)

jloader-qfx-13.3-20130831_pr_branch_qfd.0.tgz

Jloader Software Version 1.1.4 Guidelines
Jloader Release 1.1.4 is compatible with Junos OS Release 11.3R3 and 11.3R2, and Junos OS Release 12.1R1 and later. Jloader Release 1.1.4 is not compatible with Junos OS
Release 11.3R1. The Jloader software package names are different for versions 1.1.4 (Junos OS 11.3R3 and 11.3R2) and 1.1.4 (Junos OS 12.2R1 release and later), but the binaries are the same. Because the binaries are the same, you can upgrade or downgrade to any Junos OS release.
· If you have Junos OS Release 11.3 installed and want to upgrade the Jloader software from version 1.1.2 to version 1.1.4, you need to upgrade using the jloader-qfx-11.3I20120127_0733_dc-buildersigned.tgz software package.
· If you have Junos OS Release 11.3R2 installed and want to upgrade to Junos OS Release 12.1, you do not need to upgrade the Jloader Release and can continue to use Jloader Release 1.1.2.
· If you have Junos OS Release 12.1 installed and want to upgrade the Jloader software from version 1.1.2 to version 1.1.4, you need to upgrade using the jloader-qfx-12.1-20120125_pr.0-signed.tgz software package.
· If you upgrade to Junos OS Release 12.1, you can upgrade to Jloader Release 1.1.4 using the jloaderqfx-12.1-20120125_pr.0-signed.tgz software package.
Upgrading Jloader Software on a QFX3500 Switch
The Jloader software for a QFX3500 switch resides in two flash memory banks. At any time, one bank acts as the primary bank, and the QFX3500 switch boots from it. The other bank is the backup bank--if the QFX3500 switch cannot boot from the primary bank, it boots from the backup bank. When you

172
upgrade the Jloader software, the upgraded software is installed in the backup bank, which then becomes the new primary bank. Thus the primary and backup banks alternate each time you upgrade the Jloader software, with the primary bank containing the most recently installed version of the software, and the backup bank containing the previous version. To upgrade the Jloader software on a QFX3500 switch, you must perform the upgrade twice: once for each bank. Each upgrade requires that you to reboot the QFX3500 switch.
NOTE: If you are running Junos OS Release 11.3R1 or Junos OS Release 11.3R2, you must use the no-validate option when you issue the request system software add command to upgrade the Jloader software. Otherwise, the installation will fail and you receive a configuration error. The no-validate option is not required for Junos OS Release 11.3R3 and later.
NOTE: After you upgrade the Jloader software on the first bank, the software package is deleted after you reboot. Make sure that you have either downloaded the Jloader software package to either a remote site or in a local directory on the switch, such as the /var/tmp directory on the QFX3500 device.
1. In a browser, go to https://support.juniper.net. The Junos Platforms Download Software page appears.
2. In the QFX Series section of the Junos Platforms Download Software download page, select the QFX Series platform software you want to download.
3. Select the number of the software version that you want to download. 4. Read the End User License Agreement, click the I agree radio button, and then click Proceed. 5. Open or save the jloader-qfx-version-signed.tgz file either to a local system or to a remote
location. If you are saving the installation package to a remote system, make sure that you can access it using HTTP, TFTP, FTP, or scp. 6. Log in to the QFX3500 switch and enter the shell. We recommend using a console connection. 7. Determine the version of the Jloader software package installed on the switch. For example:
root@switch% ls gres-tp krt_gencfg_filter.txt jloader-qfx-11.3-20110510.0-signed.tgz
8. Determine the version of the Uboot software that is running in the bank:

173
For example:
root@switch% kenv | grep boot.version
boot.version="1.0.7"
9. Enter the CLI and install the Jloader software package. · To install a Jloader software package that is located in the /var/tmp directory, issue the request system software add /var/tmp/jloader-qfx-version.tgz no-validate command: For example:
user@switch> request system software add /var/tmp/jloader-qfx-11.3-20110510.0-signed.tgz no-validate
You see the following messages during the installation:
Verified jloader-qfx-11.3-20110510.0.tgz signed by PackageProduction_11_3_0 Adding jloader-qfx... Installation in progress, please wait... Mounted jloader-qfx package on /dev/md8... Verified manifest signed by PackageProduction_11_3_0 Verified jloader-qfx-11.3-20110510.0 signed by PackageProduction_11_3_0 Registering jloader-qfx as unsupported
Installation finished successfully. Please reboot to activate the package Saving package file in /var/sw/pkg/jloader-qfx-11.3-20110510.0signed.tgz ... Saving state for rollback ...
juniper@qfx3500>
· To install a Jloader software package located on a remote server using FTP, issue the request system software add /ftp://hostname/pathname/jloader-qfx-version-signed.tgz no-validate command.

174
For example:
user@switch> request system software add /ftp://hostname/pathname/jloaderqfx-11.3-20110510.0-signed.tgz no-validate
· To install a Jloader software package located on a remote server using HTTP, issue the request system software add /http://hostname/pathname/jloader-qfx- version-signed.tgz no-validate command. For example:
user@switch> request system software add /http://hostname/pathname/jloaderqfx-11.3-20110510.0-signed.tgz no-validate 10. When prompted, reboot the Control Board by issuing the request system reboot command. For example:
user@switch> request system reboot Reboot the system ? [yes,no] (no) yes 11. Enter the shell and verify that the version of the Uboot software in the primary bank is the version you just installed. For example:
root@switch% kenv | grep boot.version
boot.version="1.1.1" 12. To install the Jloader software package on the current backup bank, repeat Step 10 through Step
14.
Upgrading Jloader Software on a QFabric System
This procedure explains how to upgrade the Jloader software on your Node devices and Interconnect devices. The example shows how to upgrade the Jloader Release 1.1.1 to 1.1.2 on a Node device with the serial number BBAK1186.

175

NOTE: Before you upgrade the Jloader software, make sure you have the serial numbers of the Node devices, Interconnect devices, and Control Boards in the Interconnect devices you want to upgrade.

1. Issue the show chassis hardware node-device ? command to view the serial numbers of the Node devices.
For example:

user@qfabric> show chassis hardware node-device ?

<node-device> BBAK1186 BBAK3149 BBAK3177 BBAK8063 BBAK8799 P2443-C P2515-C P3708-C P3885-C P3916-C node0 node1 node2 node3 node4 node5 node6 node7 node8

Node device identifier Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device Node device

An example of a Node device serial number is BBAK1186. 2. Issue the show chassis hardware interconnect-device ? command to view the serial numbers of the
Interconnect devices. For example:

user@qfabric> show chassis hardware interconnect-device ?

176

Possible completions: interconnect-device IC-F1052 IC-F3947

Interconnect device identifier Interconnect device Interconnect device

The Interconnect device serial numbers are IC-F1052 and IC-F3947. 3. Issue the show chassis hardware interconnect-device name command to view the serial numbers
of the Control Boards in the Interconnect device.
For example:

user@qfabric> show chassis hardware interconnect-device IC-F3947

Hardware inventory:

Item

Version

Chassis

REV 10

Midplane

REV 10

CB 0

REV 14

Board

Routing Engine 0

CB 1

REV 14

Board

Part number
750-035835 750-035855
BUILTIN 750-035855

Serial number F3947 F3947-C ZJ9432
BUILTIN ZJ9404

Description QFXC08-3008 QFX Midplane QFX Chassis Control
QFX Routing Engine QFX Chassis Control

The Control Board serial numbers are ZJ9432 and ZJ9404. 4. Issue the show chassis firmware node-device name command to see which version of Uboot
software you have installed on your Node device.
For example:

user@qfabric> show chassis firmware node-device BBAK1186

Part node4 1.1.1
0.1

Type U-Boot
loader

Version 1.1.6 (May 10 2011 - 04:52:59)
FreeBSD/MIPS U-Boot bootstrap loader

The Uboot software version is 1.1.1. The loader software version appears after the timestamp for U-Boot 1.1.6.
5. Issue the show chassis firmware interconnect-device name command to see which version of Uboot software you have installed on the Routing Engines located on the Control Boards of the Interconnect device.

177

For example:

user@qfabric> show chassis firmware interconnect-device IC-F3947

Part Routing Engine 0 1.1.4
0.1 Routing Engine 1 1.1.4
0.1

Type U-Boot loader U-Boot loader

Version U-Boot 1.1.6 (Jan 27 2012 - 03:24:34) FreeBSD/MIPS U-Boot bootstrap loader U-Boot 1.1.6 (Jan 27 2012 - 03:24:34) FreeBSD/MIPS U-Boot bootstrap loader

The Uboot software version is 1.1.4. The loader software version appears after the timestamp for U-Boot 1.1.6. 6. In a browser, go to https://support.juniper.net. The Downloads page appears. 7. Select the product you want software for. 8. Find and click the file you want to download. A login screen appears. 9. Enter your username and password, and press Enter. 10. Read the End User License Agreement, click the I agree radio button, and then click Proceed. 11. Open or save the jloader-qfx-version-signed.tgz file either to a local system or to a remote location. If you are saving the installation package to a remote system, make sure that you can access it using HTTP, TFTP, FTP, or scp. 12. Retrieve the software from the location in which you downloaded it. To do this, issue the request system software download /path/package-name command.

For example:
user@qfabric> request system software download ftp://server/files/jloader-qfx-11.3X30.9signed.tgz
13. Log in to the Director device as root and enter the shell to verify that you have downloaded the Jloader software package. We recommend using a console connection. The software package is copied from where you downloaded it and is placed locally on the QFabric system in the /pbdata/ packages directory.

178

For example:

[root@dg0] # pwd /pbdata/packages [root@dg0] # ls jloader-qfx-11.3X30.9-signed.tgz
14. Before you copy over the Jloader software package to the Node device or Interconnect device, determine the directory that matches the serial number of the Node device or Interconnect device that you want to upgrade. View the remote logs and the Node device and Interconnect device serial numbers by issuing the ls /pdbata/export/rlogs command at the command line of the Director device before you copy the software package over to the device.
NOTE: The /pbdata/export/rlogs/node-device-serial-ID and /pbdata/export/rlogs/ interconnect-device-serial-ID directories on the Director device are NFS mounted as the / tftpboot/logfiles directories on the Node device and Interconnect device. These directories are created for all Node devices and Interconnect devices in a QFabric system. The Jloader files are stored in the /tftpboot/logfiles directories for each Node device and Interconnect device.

For example:

[root@dg0 tmp] # ls /pdbata/export/rlogs 02de4930-828b-11e1-a319-00e081c57938 04103b2a-29d5-e011-bf8a-0e6bdf3aa1e6 1e2739e0-828b-11e1-bf74-00e081c57938 8d8a978c-828b-11e1-a833-00e081c57938 ad55b89e-828b-11e1-b70e-00e081c57938 BBAK1186 BBAK3149 BBAK3177 BBAK8063 BBAK8799

c9898afe-828b-11e1-956c-00e081c57938 eeba4aac-828b-11e1-85e2-00e081c57938 F1052 F3947 P2443-C P2515-C P3708-C P3885-C P3916-C

BBAK1186 is the serial number of the Node device that needs to be upgraded.
15. Copy the Jloader software package from the /var/tmp directory to the /pbdata/export/rlogs/ BBAK1186 directory.

179

For example:

[root@dg0 tmp] # cp jloader-qfx-11.3X30.9-signed.tgz /pbdata/export/rlogs/BBAK1186
16. Confirm that the Jloader software package you copied over is in the /pbdata/export/rlogs/ BBAK1186 directory. For example:

[root@dg0 tmp] # ls /pbdata/export/rlogs/BBAK1186 jloader-qfx-11.3X30.9-signed.tgz
17. Issue the /root/dns.dump command to find out the internal IP addresses of the Node device or Interconnect device.

[root@dg0 tmp] # /root/dns.dump

; <<>> DiG 9.3.6-P1-RedHat-9.3.6-4.P1.el5 <<>> -t axfr pkg.test.device.net

@169.254.0.1

;; global options: printcmd

pkg.test.device.net. 600

IN

SOA

ns.pkg.test.device.net.

mail.pkg.test.device.net. 152 3600 600 7200 3600

pkg.test.device.net. 600

IN

NS

ns.pkg.test.device.net.

pkg.test.device.net. 600

IN

A

169.254.0.1

pkg.test.device.net. 600

IN

MX

1 mail.pkg.test.device.net.

dcfnode---DCF-ROOT.pkg.test.device.net. 45 IN A 169.254.192.17

dcfnode---DRE-0.pkg.test.device.net. 45 IN A 169.254.3.3

dcfnode-8d8a978c-828b-11e1-a833-00e081c57938.pkg.test.device.net. 45 IN A

169.254.128.19

dcfnode-ad55b89e-828b-11e1-b70e-00e081c57938.pkg.test.device.net. 45 IN A

169.254.128.20

dcfnode-BBAK1186.pkg.test.device.net. 45 IN A 169.254.128.14

The internal IP address for BBAK1186 is 169.254.128.14. 18. Upgrade the Jloader software on the Node device or Interconnect device.
Before you can upgrade the Jloader software, you need to use SSH to log in to the Node device or Interconnect device and verify that the software is in the /tftpboot/logfiles directory.
a. Use SSH to log in to the Node device or Interconnect device.

180

For example:

[root@dg0 tmp] # ssh 160.254.128.14 root@169.254.128.14's password: --- JUNOS 11.3X30.10 built 2012-03-11 22:55:43 UTC At least one package installed on this device has limited support. Run 'file show /etc/notices/unsupported.txt' for details. root@sng3%
b. Verify that the Jloader software package is in the tftpboot/logfiles directory of the Node device or Interconnect device. For example:

root@sng3% ls /tftpboot/logfiles .index

jloader-qfx-11.3X30.9-signed.tgz

c. Copy the Jloader software package from the /tftpboot/logfiles directory to the /var/tmp directory of the Node device or Interconnect device.
For example:

root@sng3% cp /tftpboot/logfiles/jloader-qfx-11.3X30.9-signed.tgz /var/tmp
d. Verify that the Jloader software package is in the /var/tmp directory of the Node device or Interconnect device. For example:

root@sng3% ls /var/tmp

.snap

signed.tgz

tmp

gres-tp

krt_gencfg_filter.txt

if-rtsdb

jloader-qfx-11.3X30.9-
vc-autoupgrade rtsdb

e. Enter CLI mode and issue the request system software add /var/tmp/jloader-qfx-versionsigned.tgz command.

181
For example:
root@sng3% cli root@sng3> request system software add /var/tmp/jloader-qfx-11.3X30.9-signed.tgz Validating on fpc0 Checking compatibility with configuration Initializing... Using jbase-11.3X30.10 Verified manifest signed by PackageProduction_11_3_0 Verified jbase-11.3X30.10 signed by PackageProduction_11_3_0 Using /var/tmp/jloader-qfx-11.3X30.9-signed.tgz Verified jloader-qfx-11.3X30.9.tgz signed by PackageProduction_11_3_0 Using jloader-qfx-11.3X30.9.tgz Checking jloader-qfx requirements on / Verified manifest signed by PackageProduction_11_3_0 Verified jloader-qfx-11.3X30.9 signed by PackageProduction_11_3_0 Using jkernel-qfx-11.3X30.10 Verified manifest signed by PackageProduction_11_3_0 Verified jkernel-qfx-11.3X30.10 signed by PackageProduction_11_3_0 Using jroute-qfx-11.3X30.10 Verified manifest signed by PackageProduction_11_3_0 Verified jroute-qfx-11.3X30.10 signed by PackageProduction_11_3_0 Using jcrypto-qfx-11.3X30.10 Verified manifest signed by PackageProduction_11_3_0 Verified jcrypto-qfx-11.3X30.10 signed by PackageProduction_11_3_0 Using jweb-qfx-11.3X30.10 Verified manifest signed by PackageProduction_11_3_0 Verified jweb-qfx-11.3X30.10 signed by PackageProduction_11_3_0 Using jswitch-qfx-11.3X30.10 Verified manifest signed by PackageProduction_11_3_0 Verified jswitch-qfx-11.3X30.10 signed by PackageProduction_11_3_0 Hardware Database regeneration succeeded Validating against /config/juniper.conf.gz mgd: commit complete Validation succeeded Done with validate on all chassis
fpc0: Verified jloader-qfx-11.3X30.9.tgz signed by PackageProduction_11_3_0 Adding jloader-qfx... Installation in progress, please wait... Mounted jloader-qfx package on /dev/md10...

182
Verified manifest signed by PackageProduction_11_3_0 Verified jloader-qfx-11.3X30.9 signed by PackageProduction_11_3_0 ####################################### ########################################################################## ########################################################################## ############################################ Installation finished successfully. Please reboot to activate the package Saving package file in /var/sw/pkg/jloader-qfx-11.3X30.9-signed.tgz ... Saving state for rollback ...

Upgrade has completed successfully. Reboot is now required.
f. Reboot both the Node device and Interconnect device twice, because they each contain two partitions. For example:

root@sng3> request system reboot Reboot the system ? [yes,no] (no) yes Shutdown NOW! [pid 37663]
root@sng3>
*** FINAL System shutdown message from root@sng3 *** System going down IMMEDIATELY
g. Verify that the Uboot software on the Node device or Interconnect device has been upgraded to the new Uboot software by logging in to the QFabric CLI and issuing either the show chassis firmware node-device name command or the show chassis firmware interconnect-device name command. For example:

user@qfabric> show chassis firmware node-device BBAK1186

Part

Type

Version

node4

U-Boot

1.1.6 (Nov 19 2011 - 11:42:07)

1.1.2

183

loader

FreeBSD/MIPS U-Boot bootstrap loader

0.1

The Uboot software version is now 1.1.2. The loader software version appears after the timestamp for U-Boot 1.1.6.

SEE ALSO Performing a Nonstop Software Upgrade on the QFabric System Upgrading Software on a QFabric System

Installing Junos OS Software with Junos Automation Enhancements
Before you install software, download the Junos OS jinstall-qfx-5-flex-x.tgz software bundle. For information on downloading and accessing the files, see "Installing Software Packages on QFX Series Devices" on page 151. Junos operating system (Junos OS) with Junos Automation Enhancements is a full-featured version of Junos OS with Veriexec disabled, which can only be installed on supported devices.
NOTE: You must install the jinstall-qfx-5-flex-x.tgz software bundle in order to use the automation enhancements.

BEST PRACTICE: Before you install the software, back up any critical files in /var/home. For more information regarding how to back up critical files, contact Customer Support at https:// www.juniper.net/support.
Install the software: 1. Issue the request system software add command with the validate option:
· If the installation package resides locally on the switch, issue the request system software add validate pathname source reboot command, using the following format:
user@switch> request system software add validate /var/tmp/jinstall-qfx-5-flex-x.tgz reboot

184
· If the installation package resides remotely, issue the request system software add validate pathname source reboot command, using the following format:
user@switch> request system software add validate ftp://ftpserver/directory/jinstall-qfx-5-flexx.tgz reboot
2. After the reboot has finished, verify that the new version of software has been properly installed by executing the show version command.
user@switch> show version fpc0: -------------------------------------------------------------------------Hostname: qfx5100-24q-et013 Model: qfx5100-24q-2p JUNOS Base OS Software Suite [13.2X51-D20] JUNOS Base OS boot [13.2X51-D20] JUNOS Crypto Software Suite [13.2X51-D20] JUNOS Online Documentation [13.2X51-D20] JUNOS Kernel Software Suite [13.2X51-D20] JUNOS Packet Forwarding Engine Support (qfx-x86-32) [13.2X51-D20] JUNOS Routing Software Suite [13.2X51-D20] JUNOS Enterprise Software Suite [13.2X51-D20] JUNOS py-base-i386 [13.2X51-D20] Puppet on Junos [2.7.19_1.junos.i386] Ruby Interpreter [11.10.4_1.junos.i386] Chef [11.10.4_1.junos.i386] junos-ez-stdlib [11.10.4_1.junos.i386] JUNOS Host Software [13.2X51-D20] JUNOS for Automation Enhancement
NOTE: If you are upgrading a device from standard Junos OS to use Junos Automation Enhancements and you are not loading the new factory default configuration, you need to use the following procedure. 1. Edit your existing Junos OS configuration to include the following configuration statements:

185
[edit] user@switch# set system extensions providers juniper license-type juniper deploymentscope commercial user@switch# set system extensions providers chef license-type juniper deploymentscope commercial
NOTE: The factory default configuration of the QFX5100 switch jinstall-qfx-5-flex-x.tgz software bundle is a Layer 3 configuration, whereas the factory default configuration for QFX5100 switch software bundles is a Layer 2 configuration. Therefore, if you are running the jinstall-qfx-5-flexx.tgz software bundle on a QFX5100 switch and you use the load factory-default command, the resulting factory default configuration is set up for Layer 3 interfaces.
This is the factory default configuration for QFX5100 switch jinstall-qfx-5-flex-x.tgz software bundle:
user@switch> show configuration
system syslog user * any emergency system syslog file messages any notice system syslog file messages authorization info system syslog file interactive-commands interactive-commands any system extensions providers juniper license-type juniper deployment-scope commercial system extensions providers chef license-type juniper deployment-scope commercial system commit factory-settings reset-virtual-chassis-configuration system commit factory-settings reset-chassis-lcd-menu system processes app-engine-virtual-machine-management-service traceoptions level notice system processes app-engine-virtual-machine-management-service traceoptions flag all interfaces et-0/0/0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/0:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/0:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/0:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/0:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p

186
interfaces xe-0/0/1:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/1:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/1:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/1:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/2:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/2:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/2:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/2:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/3:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/3:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/3:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/3:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/4 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/4:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/4:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/4:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/4:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/5 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/5:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/5:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/5:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/5:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/6 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/6:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/6:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/6:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/6:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/7 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/7:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/7:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/7:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/7:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/8 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/8:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/8:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/8:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/8:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/9 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/9:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/9:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/9:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p

187
interfaces xe-0/0/9:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/10 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/10:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/10:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/10:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/10:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/11 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/11:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/11:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/11:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/11:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/12 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/12:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/12:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/12:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/12:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/13 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/13:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/13:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/13:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/13:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/14 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/14:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/14:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/14:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/14:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/15 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/15:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/15:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/15:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/15:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/16 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/16:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/16:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/16:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/16:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/17 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/17:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/17:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/17:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/17:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/18 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/18:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p

188
interfaces xe-0/0/18:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/18:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/18:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/19 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/19:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/19:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/19:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/19:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/20 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/20:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/20:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/20:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/20:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/21 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/21:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/21:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/21:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/21:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/22 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/22:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/22:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/22:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/22:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/0/23 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/23:0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/23:1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/23:2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces xe-0/0/23:3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/1/0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/1/1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/1/2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/1/3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/2/0 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/2/1 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/2/2 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p interfaces et-0/2/3 unit 0 family inet dhcp vendor-id Juniper-qfx5100-24q-2p forwarding-options storm-control-profiles default all protocols lldp interface all protocols lldp-med interface all protocols igmp-snooping vlan default vlans default vlan-id 1

189
SEE ALSO Overview of Junos Automation Enhancements on Devices Running Junos OS with Enhanced Automation
How To Install Third-Party Software on Devices Running Junos OS Evolved
Third-party software is software that is not part of the normal release cadence for a given target chassis. In the case of Junos OS Evolved, third-party software refers to the following types of software delivered to a node or a cluster of nodes running Junos OS Evolved: · Private software developed by external customers · Software or tools developed by internal engineers Third parties package their software as .tgz files. The package filename contains the component name and its version as well as the architecture and SDK version. You install the third-party software package on a device running Junos OS Evolved using the request system software add filename command. This is the same command you use to install different releases of the Junos OS Evolved software on a device. The only difference is that third-party software are .tgz files and the Junos OS Evolved software are .iso files. The procedure is the same as installing software on any device running Junos OS. You back up the current system and you place the software on the device, usually in the /var/tmp directory of the active Routing Engine. For example, if you have third-party software developed by Acme with the filename acmeMonitor-1.2.3_Wrl_9.0_x86_64.tgz, use the following command to install it on a device running Junos OS Evolved:
user@host> request system software add /var/tmp/acmeMonitor-1.2.3_Wrl_9.0_x86_64.tgz
NOTE: The reboot command is not needed to install third-party applications on devices running Junos OS Evolved.

190
NOTE: For Junos OS Evolved, if you are trying to reinstall an already installed application, use the force option. The force option will cause the program to remove the existing application before reinstalling it.
The program detects third-party components already installed in the current version that collide with new components in acmeMonitor-1.2.3_Wrl_9.0_x86_64.tgz. Without using the force option, a reinstall of a third-party application fails. Use the show version command to see a list of the current components installed that are not part of the released BOM. The list is tagged as "External Software" and gives the name of each third-party component name and version, as well as the SDK version that was used to create it.
user@host> show version Model: ptx10003-160c Junos: 20.1-201910240713.0-EVO Junos Package: junos-evo-install-ptx-fixed-x86-64-20.1-201910240713.0-EVO.iso Yocto: 2.2.1 Linux Kernel: 4.8.28-WR2.2.1_standard-g21fb4b9 SDK version: 5.6.7 External Software:
acmeMonitor-1.2.3 [sdk 5.6.7] acmeLoadShare-3.4.5 [sdk 5.6.8]
You remove third-party software the same way you remove versions of Junos OS Evolved, for example, to remove the Acme software, use this command:
user@host> request system software delete acmeMonitor
If you want to delete all third-party software, use the request system software delete all-third-partypackages command.
RELATED DOCUMENTATION request system software add (Junos OS Evolved) | 0 request system software delete (Junos OS Evolved) | 0 show version

191
Personality Upgrade Process
IN THIS SECTION Understanding the Personality Upgrade Process for a Device | 191 Supported Personality Upgrades | 193 Upgrading the Personality of a Device by Using a USB Flash Drive | 194 Upgrading the Personality of a Device by Using CLI | 195 Upgrading the Personality of a Device by Using a PXE Boot Server | 198 Upgrading the Personality of SRX1500 Device by Using a PXE Boot Server | 202 Upgrading the Personality of SRX4100 Device by Using a PXE Boot Server | 206 Upgrading the Personality of SRX4600 Device by Using a PXE Boot Server | 210
Understanding the Personality Upgrade Process for a Device
IN THIS SECTION Benefits of Personality Upgrade | 192 Guidelines and Restrictions | 192
Personality of a device can be defined as a combination of the purpose of the device and the solution that the device provides. For instance, a switch is a Layer 2 (Data Link Layer) device that is designed to connect two or more networking devices on a network. Most switches (except a few Layer 3 switches) act as bridge devices that receive data packets from a source device, process the data, and forward it to a destination device within the same network. A router, in contrast, connects multiple networks. It is typically a Layer 3 (Network Layer) device because its primary function is to forward packets destined either for its own network or for other networks. Starting in Junos OS Release 18.2R1, you can upgrade the personality of a device from the installed personality to a new personality without having to upgrade the entire device.

192
The build image loaded on a device defines the personality of the device. For instance, suppose you purchase a core router such as a PTX10008. The build image loaded on the router indicates its installed personality--that is, PTX10008. You can upgrade its personality and use it as an edge router such as an MX10008, in which case the device personality changes to MX10008. Similarly, you can change the device personality from an MX10008 to a PTX10008. You can also alternate between a switch (for example, QFX10002-60C) and a router (say, PTX10002-60C) by simply upgrading the device personality. To upgrade the device personality from one device to another, you need certain common hardware components supported by both the devices. In the case of an MX10008 and a PTX10008, the presence of the common Routing and Control Board (RCB)--JNP10K-RE1--and the eight-slot universal chassis-- JNP10008--enables you to upgrade from one device to the other seamlessly.
NOTE: When you order a spare JNP10K-RE1 RCB, the image of the MX10008 build is installed on that RCB. The spare JNP10K-RE1 also contains an image of the PTX10008 build at the /var/tmp location. You can upgrade an MX10008 router to an PTX10008 by using that image.
You can upgrade the personality of the device to a new personality by: · Using the USB flash drive
· Using the Junos OS CLI
· Using the PXE boot server
Benefits of Personality Upgrade
· Reuse--The same device (universal chassis) can be used as an edge router or a core router or a switch.
· Time-saving--You can quickly deploy the new device personality in the network.
· Lower capital expenditure and operating costs--You can upgrade the device personality instead of purchasing a new device.
· Network Growth management--Upgrading the personality of your device helps you manage the network growth when growth forecasts are discouraging.
· Lower inventory and storage costs for distributors.
Guidelines and Restrictions
This section describes the guidelines to consider when you upgrade the personality of a device:

193
· If you attempt to upgrade the personality of the device without using the recommended CLI command, the device can become inaccessible and unstable. For more information, see "Upgrading the Personality of a Device by Using CLI".
· There are no in-built restrictions or checks to validate the image that you plan to install on the device.
· Verify that the installed image supports the required command to upgrade to the new personality. If it does not, upgrade to a later version of the image before you upgrade to the new personality.
· When you upgrade the personality of the device, the configuration present in the device is migrated to the new personality. This is similar to a Junos OS upgrade. Therefore, any configuration that is not supported on the new personality must be deleted before you upgrade the personality. If any unsupported configuration is retained in the device after it reboots with the new image, the device returns to the factory-default configuration.
· Retain the minimum configuration required on the device, so the management interface is accessible.
NOTE: Juniper Networks does not support using the request vmhost software rollback command to revert to the previously installed personality.

Supported Personality Upgrades

Table 12 on page 193 displays the various combinations of device personality upgrades that are supported by Junos OS.
Table 12: Supported Personality Upgrades on Junos OS

Installed Personality New Personality Initial Junos OS Release

Common HW Component

MX10008

PTX10008

18.2

Routing and Control Board (JNP10KRE1)

PTX10008

MX10008

18.2

Routing and Control Board (JNP10KRE1)

194

Table 12: Supported Personality Upgrades on Junos OS (Continued)

Installed Personality New Personality Initial Junos OS Release

Common HW Component

QFX10002-60C

PTX10002-60C 18.2

PTX10002-60C

QFX10002-60C 18.2

MX10016

PTX10016

18.4

Routing and Control Board (JNP10KRE1)

PTX10016

MX10016

18.4

Routing and Control Board (JNP10KRE1)

There are multiple ways to change the personality of a device: · "Upgrading the Personality of a Device by Using a USB Flash Drive" · "Upgrading the Personality of a Device by Using CLI" · "Upgrading the Personality of a Device by Using a PXE Boot Server"

Upgrading the Personality of a Device by Using a USB Flash Drive
The build image loaded on the device defines the personality of the device. You can change the personality of the device by upgrading it. In a USB upgrade, the content of the SSDs are erased and the image is installed from the USB flash drive to both the primary and secondary disks. Based on the image used, the device comes up as a PTX10008 or an MX10008. This is irrespective of the previously installed personality of the device.
NOTE: When you order a spare JNP10K-RE1 RCB, the image of the MX10008 build is installed on that RCB. The spare RCB also contains an image of the PTX10008 build at the /var/tmp location. You can upgrade an MX10008 router to an PTX10008 by using that image.
To upgrade the personality of the device by using a USB flash drive:

195
1. Insert the external USB flash drive. The external flash drive is detected. 2. Reboot the device.
user@host# run request vmhost reboot usb OR user@host# run request vmhost reboot 3. When prompted, unplug the USB flash drive after the system reboots.
NOTE: Juniper Networks does not support using the request vmhost software rollback command to revert to the previously installed personality.
Upgrading the Personality of a Device by Using CLI
IN THIS SECTION How to Upgrade the Personality of a Device on Junos OS | 195
The build image loaded on the device defines the personality of the device. You can change the personality of the device by upgrading it. You can upgrade the personality of the device by using CLI configuration on devices running Junos OS.
NOTE: When you order a spare JNP10K-RE1 RCB, the image of the MX10008 build is installed on that RCB. The spare RCB also contains an image of the PTX10008 build at the /var/tmp location. You can upgrade an MX10008 router to an PTX10008 by using that image.
How to Upgrade the Personality of a Device on Junos OS
Use the following CLI procedure to upgrade the personality of a device running Junos OS. · Verify that the installed image supports the required CLI command to upgrade to the new
personality. If it does not, upgrade to a later version of the image before you upgrade to the new personality.

196
· Delete any configuration that is not supported or is not compatible with the new personality before you upgrade the personality. If any unsupported configuration is retained in the device after it reboots with the new image, the device returns to the factory-default configuration.
To upgrade the device to a new personality by using the Junos OS CLI: 1. In operational mode, verify the installed personality of the device. If you have purchased an
MX10008 device, the installed personality of the device is displayed as mx10008. If you have purchased a PTX10008 device, the installed personality of the device is displayed as ptx10008.
user@host> show version
Hostname: host Model: mx10008
Hostname: host Model: ptx10008 2. Download the software package or build image from https://www.juniper.net/support/. For information about downloading software packages, see "Downloading Software" on page 107. Save
the software package to the /var/path/package-name directory on the router. For example, you can save the software package to the /var/tmp directory.
NOTE: Download the software package specific to the personality you want to upgrade to. The software package for PTX Series routers is different from the software package for MX Series routers.
3. In configuration mode, install the software package by using the request vmhost software add path/ package-name command. Install the software package based on the new personality you want to upgrade to, as follows:
user@host# run request vmhost software add /var/tmp/junos-vmhost-install-ptx-x86-64-xyz.tgz upgrade-to-model ptx10008 no-validate
user@host# run request vmhost software add /var/tmp/junos-vmhost-install-mx-x86-64-zyx.tgz upgrade-to-model mx10008 no-validate

197
NOTE: If you do not specify the no-validate option, the router displays the following error message: error: Upgrading to a different model is supported only with no-validate option. 4. Reboot the router so the new package is loaded.
user@host# run request vmhost reboot 5. Run the show version command to verify that the upgrade is successful. If you have upgraded the
personality of the device to an MX10008 device, the new personality of the device is displayed as mx10008. If you have upgraded the personality of the device to a PTX10008 device, the new personality of the device is displayed as ptx10008.
user@host> show version
Hostname: host Model: ptx10008
Hostname: host Model: mx10008
NOTE: Juniper Networks does not support using the request vmhost software rollback command to revert to the previously installed personality.
To ensure that all four partitions are upgraded to the same personality, follow these steps: 1. Boot from the solid-state drive (SSD) Disk 2 by using the request vmhost reboot command.
user@host> request vmhost reboot disk2

198
2. Upgrade to the new personality by using the upgrade-to-model and no-validate options. This command upgrades both partitions on the SSD Disk 1.
user@host# run request vmhost software add junos-vmhost-install-x.tgz upgrade-to-model X novalidate reboot
If you are upgrading to PTX10008, include the package for the PTX Series routers and replace X with ptx10008 before the no-validate option. If you are upgrading to MX10008, include the package for the MX Series routers and replace X with mx10008 before the no-validate option. 3. After the device boots up from SSD Disk 1, take a snapshot from SSD Disk 1 to Disk 2.
user@host> request vmhost snapshot partition
This step ensures that both partitions on Disk 2 are upgraded to the new personality. After you complete Step 1 through Step 3, all four partitions are upgraded to new personality.
Upgrading the Personality of a Device by Using a PXE Boot Server
The build image loaded on the device defines the personality of the device. You can change the personality of the device by upgrading it. You can upgrade the personality of a device by using the Preboot Execution Environment (PXE) boot server. A PXE boot prepares a client/server environment to boot devices by using a network interface that is independent of available data storage devices or installed operating systems. The image of the operating system is stored on a TFTP server. You can have a separate PXE boot server for each image.
NOTE: When you order a spare JNP10K-RE1 RCB, the image of the MX10008 build is installed on that RCB. The spare RCB also contains an image of the PTX10008 build at the /var/tmp location. You can upgrade an MX10008 router to an PTX10008 by using that image.
To upgrade the personality of a device from the installed personality to the new personality by using the PXE boot server method: · Copy the image you want installed on the device to the PXE boot server. · Reboot the device to install the image.

199
NOTE: If you have already copied the image to the PXE boot server, reboot the device to install the image.
To copy the image you want installed to the PXE boot server and install the image: 1. Copy the downloaded installation media to the /var/tmp directory in the PXE boot server.
For example:
scp /volume/build/junos/18.2/release/zyx/ship/junos-vmhost-install-netx86-64-xyz.tgz user@host:/var/tmp/
2. Log in to the PXE boot server and verify the installation file. For example:
user@host> ls -lh junos-vmhost-install-net-x86-64-xyz.tgz -rw-r--r-- 1 root root 1.8G May 24 00:42 junos-vmhost-install-net-x86-64xyz.tgz
3. Extract the junos-vmhost-install-net TAR file. For example:
user@host> tar xvzf junos-vmhost-install-net-x86-64-xyz.tgz ­C /var/tmp attributes junos-vmhost-install-ptx.tgz manifest manifest.certs manifest.ecerts manifest.esig manifest.sig package.xml pkg_add_vmhost.sh vmhost-install-net-x86_64-xyz.tgz
4. Remove the previously installed files, if any, from the /tftpboot directory.
user@host> rm -f /tftpboot user@host> mkdir /tftpboot

200
5. Extract the network installation package. For example:
user@host> tar xvzf /var/tmp/vmhost-install-net-x86_64-xyz.tgz -C /tftpboot/ ./ ./vmhost-version.sh ./bootpxe64.efi ./vmhost-version ./grub.cfg .. ... -rw-rw-r-- 1 930 930 45M Oct 20 01:51 vmhost-install-net-x86_64-xyz.tgz -rw-rw-r-- 1 930 930 6 Oct 20 01:51 vmhost-version -rwxrwxr-x 1 930 930 416 Oct 20 01:51 vmhost-version.sh -rw-r--r-- 1 930 930 6.9M Oct 20 01:51 vmlinuz
6. Rename or delete the previously installed root file system/scripts from the /var/install directory. Create a new /var/install directory.
user@host>mv /var/install /var/install_old user@host>mkdir /var/install
7. Extract the installation package. For example, this sample output is specific to the PTX Series device installation package.
user@host>tar xvzf /var/tmp/junos-vmhost-install-ptx.tgz -C /var/install ./ ./vmhost-pkgs-version ./vm/ ./vm/note ./vm/grub.cfg.ngre ./vm/vsmartd-1.0-0.x86_64.rpm ./vm/re_fpga-1.0-0.x86_64.rpm ./vm/veccd-1.0-0.x86_64.rpm ./vmhost-version.sh ./vmhost/ ./vmhost/vmhost-x86_64-xyz.img.gz ... ...

201
./junos/junos-mtre-upgrade.sh ./vmhost-core-x86_64-15.1I20151019_1021_builder.tgz ./junos/ ./junos/junos-install-x86-64-xyz.img.gz 8. Verify that the /var/install folder contains the attributes file. If the file does not exist in the specified location, copy the attribute file.
NOTE: The attribute file consists of the personality information of the image. If the attributes file is not present, the device is unable to upgrade to the new personality even when the PXE boot server has the relevant image.
user@host> mv /var/tmp/attributes /var/install 9. Set permissions for the files in the /var/install and /tftpboot directories.
user@host> chown root:root /tftpboot/* user@host> user@host> chown -R root:root /var/install user@host> chmod -R a+rwx /var/install 10. Exit the PXE boot server.
user@host> exit 11. After you copy the image to the PXE boot server, to install the image on the device, reboot the
device to install the image.
user@host> request vmhost reboot network
The router boots from the PXE server and installs the image on both the SSDs. If the device fails to reboot, you can use the USB disk installation option. For more information, see "Upgrading the Personality of a Device by Using a USB Flash Drive". However, after using USB disk installation, if the router fails to reboot or is not accessible, follow these steps on the console: 1. Power cycle the chassis or remove the RCB (JNP10K-RE1) and plug it back in. 2. Press the ESC button to go to the Boot Manager Menu.

202
3. Select Boot Manager, and then press Enter. 4. Select the ETH00 (xx:xx:xx:xx:xx:xx) option. A warning message is displayed. At the prompt, select y
to install the image on both the primary and secondary disks.
WARNING: The installation will erase the contents of your disks. Install vmhost and Junos Software on Primary and Secondary disk [y/n] y
5. In operational mode, verify that the upgrade is successful. If you have upgraded the personality of the device to an MX10008, the new personality of the device is mx10008. If you have upgraded the personality of the device to a PTX10008, the new personality of the device is ptx10008.
user@host> show version Hostname: host Model: ptx10008
user@host> show version Hostname: host Model: mx10008
NOTE: Juniper Networks does not support using the request vmhost software rollback command to revert to the previously installed personality.
Upgrading the Personality of SRX1500 Device by Using a PXE Boot Server
The build image loaded on the device defines the personality of the device. You can change the personality of the device by upgrading it. You can upgrade the personality of a device by using the Preboot Execution Environment (PXE) boot server. A PXE boot prepares a client/server environment to boot devices by using a network interface that is independent of available data storage devices or installed operating systems. The image of the operating system is stored on a TFTP server. You can have a separate PXE boot server for each image.

203
To upgrade the personality of a device from the installed personality to the new personality by using the PXE boot server method: · Copy the image you want installed on the device to the PXE boot server. · Reboot the device to install the image. If you have already copied the image to the PXE boot server,
reboot the device to install the image. To copy the image you want installed to the PXE boot server and install the image: 1. Remove the previously installed files, if any, from the /var/lib/tftpboot/ directory.
user@host> rm -f /tftpboot user@host> mkdir /tftpboot
2. Copy the downloaded installation media to the /var/lib/tftpboot/ directory in the PXE boot server. For example:
scp /volume/build/junos/20.1/release/zyx/ship/ junos-install-media-pxe-srxentedgex86-64-20.3I-20200517_dev_common.0.1613.tgz user@host:/var/lib/tftpboot/
3. Log in to the PXE boot server and verify the installation file. For example:
user@host> ls -lh junos-install-media-pxe-srxentedgex86-64-20.3I-20200517_dev_common.0.1613.tgz -rw-r--r-- 1 root root 1.8G June 08 00:42 junos-install-media-pxe-srxentedgex86-64-20.3I-20200517_dev_common.0.1613.tgz
4. Extract the junos-install-media-pxe-srxentedge TAR file. For example:
user@host> tar xvzf junos-install-media-pxe-srxentedgex86-64-20.3I-20200517_dev_common.0.1613.tgz ­C /var/lib
./initramfs.cpio.gz ./initrd.cpio.gz ./upgrade_platform ./initramfs.cpio.gz.psig ./vmlinuz.psig

204
./HOST_COMPAT_VERSION ./application-pkg.tgz ./EFI/ ./EFI/BOOT/ ./EFI/BOOT/BOOTX64.EFI ./EFI/BOOT/grub-root.pub ./EFI/BOOT/grub-trusted.gpg.psig ./EFI/BOOT/grub-trusted.gpg ./linux.checksum ./version.txt ./host-version ./vmlinuz
5. Copy the BOOTX64.EFI file to the tftp home folder /var/lib/tftpboot/
user@host> cp EFI/BOOT/BOOTX64.EFI /var/lib/tftpboot/
6. Create a secure boot folder at /var/lib/tftpboot/
user@host> rm -rf /var/lib/tftpboot/secure-boot user@host> mkdir /var/lib/tftpboot/secure-boot
7. Copy the grub files in the secure boot folder.
user@host> cp EFI/BOOT/grub-root.pub secure-boot/ user@host> cp EFI/BOOT/grub-trusted.gpg secure-boot/ user@host> cp EFI/BOOT/grub-trusted.gpg.psig secure-boot/
8. Move initrd.cpio.gz and application-pkg.tgz in ftp server folder (/var/ftp/)
user@host> mv application-pkg.tgz /var/ftp/ user@host> mv initrd.cpio.gz /var/ftp/
9. Create grub-startup.cfg in /var/lib/tftpboot/secure-boot folder.
user@host> cat grub-startup.cfg insmod search insmod linux insmod tftp insmod reboot

205
insmod efi_gop insmod efi_uga insmod read insmod chain insmod boot insmod font insmod serial
set timeout=5
menuentry 'PXE image' { set net_default_server=192.168.120.1 echo 'Loading ...' linux (tftp)/vmlinuz root=/dev/ram quiet console=ttyS0,9600n8 acpi=ht
libata.force=noncq acpi_enforce_resources=lax install rootfs=ftp:// 192.168.120.1/initrd.cpio.gz app_pkg=ftp://192.168.120.1/applicationpkg.tgz efi=debug intel_iommu=on isolcpus=2,3
echo 'Loading initial ramdisk ...' initrd (tftp)/initramfs.cpio.gz
}
10. After you copy the image to the PXE boot server, to install the image on the device, reboot the device to install the image.
user@host> request system reboot
The router boots from the PXE server and installs the image on both the SSDs. If the device fails to reboot, you can use the USB disk installation option. For more information, see "Upgrading the Personality of a Device by Using a USB Flash Drive". However, after using USB disk installation, if the router fails to reboot or is not accessible, follow these steps on the console: 1. Reboot or power on the device
2. Press the ESC button to go to the Boot Manager Menu.
3. Select Setup Utility, and then press Enter.
4. Select the boot type as UEFI Boot Type, PXE boot capability as UEFI:IPv4, first boot device asPXE on ME and set network stack as Enabled.
5. Click F10

206
6. In operational mode, verify that the upgrade is successful. If you have upgraded the personality of the device to an SRX1500, the new personality of the device is srx1500.
user@host> show version Hostname: host Model: srx1500
Juniper Networks does not support using the request system software rollback command to revert to the previously installed personality.
Upgrading the Personality of SRX4100 Device by Using a PXE Boot Server
The build image loaded on the device defines the personality of the device. You can change the personality of the device by upgrading it. You can upgrade the personality of a device by using the Preboot Execution Environment (PXE) boot server. A PXE boot prepares a client/server environment to boot devices by using a network interface that is independent of available data storage devices or installed operating systems. The image of the operating system is stored on a TFTP server. You can have a separate PXE boot server for each image. To upgrade the personality of a device from the installed personality to the new personality by using the PXE boot server method: · Copy the image you want installed on the device to the PXE boot server. · Reboot the device to install the image. If you have already copied the image to the PXE boot server,
reboot the device to install the image. To copy the image you want installed to the PXE boot server and install the image: 1. Remove the previously installed files, if any, from the var/lib/tftpboot/ directory.
user@host> rm -f /tftpboot user@host> mkdir /tftpboot
2. Copy the downloaded installation media to the /var/lib/tftpboot/ directory in the PXE boot server.

207
For example:
scp /volume/build/junos/20.1/release/zyx/ship/ junos-install-media-pxe-srxmr-x86-64-20.3I-20200520_dev_common.0.1928.tgz user@host:/var/lib/tftpboot/
3. Log in to the PXE boot server and verify the installation file. For example:
user@host> ls -lh junos-install-media-pxe-srxmr-x86-64-20.3I-20200520_dev_common.0.1928.tgz -rw-r--r-- 1 root root 1.8G June 08 00:42 junos-install-media-pxe-srxmrx86-64-20.3I-20200520_dev_common.0.1928.tgz
4. Extract the junos-install-media-pxe-srxmr TAR file. For example:
user@host> tar xvzf junos-install-media-pxe-srxmrx86-64-20.3I-20200520_dev_common.0.1928.tgz ­C /var/lib
./initramfs.cpio.gz ./initrd.cpio.gz ./upgrade_platform ./initramfs.cpio.gz.psig ./vmlinuz.psig ./HOST_COMPAT_VERSION ./application-pkg.tgz ./EFI/ ./EFI/BOOT/ ./EFI/BOOT/BOOTX64.EFI ./EFI/BOOT/grub-root.pub ./EFI/BOOT/grub-trusted.gpg.psig ./EFI/BOOT/grub-trusted.gpg ./linux.checksum ./version.txt ./host-version ./vmlinuz

208
5. Move initrd.cpio.gz and application-pkg.tgz in ftp server folder (/var/ftp/)
user@host> mv application-pkg.tgz /var/ftp/ user@host> mv initrd.cpio.gz /var/ftp/
6. Install syslinux on ftp server.
user@host> yum install syslinux
7. Copy syslinux files to ftp server.
user@host> cp /usr/share/syslinux/menu.c32 /usr/share/syslinux/vesamenu.c32 /usr/share/syslinux/ pxelinux.0 /var/lib/tftpboot/ 8. Create PXE menu.
user@host> mkdir /var/lib/tftpboot/pxelinux.cfg
9. Create a new default file at PXE menu.
user@host> cat pxelinux.cfg/default default vesamenu.c32 prompt 0 timeout 800
#display boot.msg
#menu background splash.jpg menu title Welcome! menu color border 0 #ffffffff #00000000 menu color sel 7 #ffffffff #ff000000 menu color title 0 #ffffffff #00000000 menu color tabmsg 0 #ffffffff #00000000 menu color unsel 0 #ffffffff #00000000 menu color hotsel 0 #ff000000 #ffffffff menu color hotkey 7 #ffffffff #ff000000 menu color scrollbar 0 #ffffffff #00000000
LABEL SRXMR---20.3 MENU LABEL ^B SRXMR---20.3

209
KERNEL vmlinuz INITRD initramfs.cpio.gz APPEND vm console=ttyS0,9600n8 root=/dev/ram intel_iommu=on acpi=off isolcpus=2,3 libata.force=noncq acpi_enforce_resources=lax install rootfs=ftp://192.168.120.1/initrd.cpio.gz install app_pkg=ftp:// 192.168.120.1/application-pkg.tgz
10. After you copy the image to the PXE boot server, to install the image on the device, reboot the device to install the image.
user@host> request system reboot
The router boots from the PXE server and installs the image on both the SSDs. If the device fails to reboot, you can use the USB disk installation option. For more information, see "Upgrading the Personality of a Device by Using a USB Flash Drive". However, after using USB disk installation, if the router fails to reboot or is not accessible, follow these steps on the console: 1. Reboot or power on the device 2. Press the ESC button to go to the Boot Manager Menu. 3. Select the boot mode as LEGACY, boot option 1 as Network, and set network stack as Disabled. 4. Select save and exit or click F4 to start PXE boot. 5. Select the menu from the screen and click Enter to reboot the device. 6. Choose boot option 1 as Hard Disk. 7. Select save and exit or click F4. 8. In operational mode, verify that the upgrade is successful. If you have upgraded the personality of
the device to an SRX4100, the new personality of the device is srx4100.
user@host> show version Hostname: host Model: srx4100
Juniper Networks does not support using the request system software rollback command to revert to the previously installed personality.

210
Upgrading the Personality of SRX4600 Device by Using a PXE Boot Server
The build image loaded on the device defines the personality of the device. You can change the personality of the device by upgrading it. You can upgrade the personality of a device by using the Preboot Execution Environment (PXE) boot server. A PXE boot prepares a client/server environment to boot devices by using a network interface that is independent of available data storage devices or installed operating systems. The image of the operating system is stored on a TFTP server. You can have a separate PXE boot server for each image. To upgrade the personality of a device from the installed personality to the new personality by using the PXE boot server method: · Copy the image you want installed on the device to the PXE boot server. · Reboot the device to install the image. If you have already copied the image to the PXE boot server,
reboot the device to install the image. To copy the image you want installed to the PXE boot server and install the image: 1. Remove the previously installed files, if any, from the /var/lib/tftpboot/ directory.
user@host> rm -f /tftpboot user@host> mkdir /tftpboot
2. Copy the downloaded installation media to the /var/lib/tftpboot/ directory in the PXE boot server. For example:
scp /volume/build/junos/20.1/release/zyx/ship/ junos-install-media-pxe-srxhe-x86-64-20.3I-20200521_dev_common.0.1013.tgz user@host:/var/lib/tftpboot/
3. Log in to the PXE boot server and verify the installation file. For example:
user@host> ls -lh junos-install-media-pxe-srxhe-x86-64-20.3I-20200521_dev_common.0.1013.tgz -rw-r--r-- 1 root root 1.8G June 08 00:42 junos-install-media-pxe-srxhex86-64-20.3I-20200521_dev_common.0.1013.tgz
4. Extract the junos-install-media-pxe-srxhe TAR file.

211
For example:
user@host> tar xvzf junos-install-media-pxe-srxhe-x86-64-20.3I-20200521_dev_common.0.1013.tgz ­C /var/lib
./initramfs.cpio.gz ./initrd.cpio.gz ./upgrade_platform ./initramfs.cpio.gz.psig ./vmlinuz.psig ./HOST_COMPAT_VERSION ./application-pkg.tgz ./EFI/ ./EFI/BOOT/ ./EFI/BOOT/BOOTX64.EFI ./EFI/BOOT/grub-root.pub ./EFI/BOOT/grub-trusted.gpg.psig ./EFI/BOOT/grub-trusted.gpg ./linux.checksum ./version.txt ./host-version ./vmlinuz
5. Copy the BOOTX64.EFI file to the tftp home folder /var/lib/tftpboot/
user@host> cp EFI/BOOT/BOOTX64.EFI /var/lib/tftpboot/
6. Create a secure boot folder at /var/lib/tftpboot/
user@host> rm -rf /var/lib/tftpboot/secure-boot user@host> mkdir /var/lib/tftpboot/secure-boot
7. Copy the grub files in the secure boot folder.
user@host> cp EFI/BOOT/grub-root.pub secure-boot/ user@host> cp EFI/BOOT/grub-trusted.gpg secure-boot/ user@host> cp EFI/BOOT/grub-trusted.gpg.psig secure-boot/

212
8. Move initrd.cpio.gz and application-pkg.tgz in ftp server folder (/var/ftp/)
user@host> mv application-pkg.tgz /var/ftp/ user@host> mv initrd.cpio.gz /var/ftp/
9. Create grub-startup.cfg in /var/lib/tftpboot/secure-boot folder.
user@host> cat grub-startup.cfg insmod search insmod linux insmod tftp insmod reboot insmod efi_gop insmod efi_uga insmod read insmod chain insmod boot insmod font insmod serial
set timeout=5
menuentry 'PXE image' { set net_default_server=192.168.120.1 echo 'Loading ...' linux (tftp)/vmlinuz root=/dev/ram quiet console=ttyS0,9600n8 acpi=ht
libata.force=noncq acpi_enforce_resources=lax install rootfs=ftp:// 192.168.120.1/initrd.cpio.gz app_pkg=ftp://192.168.120.1/applicationpkg.tgz efi=debug intel_iommu=on isolcpus=2,3
echo 'Loading initial ramdisk ...' initrd (tftp)/initramfs.cpio.gz
}
10. After you copy the image to the PXE boot server, to install the image on the device, reboot the device to install the image.
user@host> request system reboot
The router boots from the PXE server and installs the image on both the SSDs.

213

If the device fails to reboot, you can use the USB disk installation option. For more information, see "Upgrading the Personality of a Device by Using a USB Flash Drive". However, after using USB disk installation, if the router fails to reboot or is not accessible, follow these steps on the console:
1. Reboot or power on the device
2. Press the ESC button to go to the Boot Manager Menu.
3. Select Setup Utility, and then press Enter.
4. Select the PXE boot capability as UEFI:IPv4, disable HDD and enable ETH00 under EPI.
5. Click F10
6. In operational mode, verify that the upgrade is successful. If you have upgraded the personality of the device to an SRX4600, the new personality of the device is srx4600.

user@host> show version Hostname: host Model: srx4600

Juniper Networks does not support using the request system software rollback command to revert to the previously installed personality.
Release History Table Release Description

18.2R1

Starting in Junos OS Release 18.2R1, you can upgrade the personality of a device from the installed personality to a new personality without having to upgrade the entire device.

RELATED DOCUMENTATION Upgrading the Personality of QFX10002-60C and PTX10002-60C Switches Using the PXE Boot Server

214
Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices
IN THIS SECTION Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the PXE Boot Server | 214 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the USB Option | 219 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the CLI Option | 220 Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using Zero Touch Provisioning (ZTP) | 222
The installed image on your devices determines the personality of the device. Juniper Networks offers benefits of changing the personality of your device. You can install the image of QFX10002-60C in PTX10002-60C device and vice versa. You can install the new personality via Preboot Execution Environment (PXE) boot method boot, USB, CLI, and ZTP.
Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the PXE Boot Server
You can configure your QFX10002-60C device as a PTX10002-60C device or your PTX10002-60C device as a QFX10002-60C device. The image loaded on the device determines the personality of the device. For example, if you have purchased a QFX10002-60C device, the installed personality is a QFX10002-60C device. When you upgrade the QFX10002-60C device to a PTX10002-60C device, the new personality of the device is a PTX10002-60C device. Similarly, if you have purchased a PTX10002-60C device, the installed personality is a PTX10002-60C device and the new personality, if you upgrade, is a QFX10002-60C device. You can install the new personality on the devices using Preboot Execution Environment (PXE) boot method. A PXE boot prepares a client/server environment to boot devices by using a network interface that is independent of available data storage devices or installed operating systems. The image of the operating system is stored on a TFTP server. You can have separate PXE boot servers for each image.

215
NOTE: When you upgrade the QFX10002-60C personality to a PTX10002-60C personality, the QFX10002-60C default configuration is deleted, and the PTX10002-60C configuration becomes the default configuration. When you upgrade the PTX10002-60C personality to a QFX10002-60C personality, the PTX10002-60C default configuration is deleted, and the QFX10002-60C configuration becomes the default configuration. Additionally, the software snapshot in the secondary disk is deleted, and the new software snapshot is installed in the secondary disk. For example, if you upgrade the QFX10002-60C personality to a PTX10002-60C personality, the QFX10002-60C snapshot is deleted, and the PTX10002-60C snapshot is installed in the secondary disk.
NOTE: When you order the spare JNP10002-60C-CHAS, it is preloaded with the QFX10002-60C and PTX10002-60C software images in the /var/tmp location. If you want to convert a QFX10002-60C device to a PTX10002-60C device, use the PTX10002-60C image. If you want to convert a PTX10002-60C device to QFX10002-60C device, use the QFX10002-60C image.
For example, to upgrade the QFX10002-60C device from the installed personality of QFX10002-60C to the new personality of PTX10002-60C device using the PXE Boot Server Option: · Copy the image you want installed on the QFX10002-60C device to the PXE Boot Server. · Reboot the device to install the image.
NOTE: If you have already copied the image to the PXE Boot server, reboot the device to install the image.
To copy the image you want installed to the PXE Boot Server: 1. Copy the downloaded installation media to the /var/tmp directory in the PXE boot server.
For example:
scp /volume/build/junos/18.2/release/zyx/ship/junos-vmhost-install-ptxx86-64-xyz.tgz user@host:/var/tmp/

216
2. Log in to the PXE boot server and verify the installation file.
user@host> ls -lh junos-vmhost-install-ptx-x86-64-xyz.tgz -rw-r--r-- 1 root root 1.8G May 24 00:42 junos-vmhost-install-net-x86-64xyz.tgz
3. Extract the junos-vmhost-install-net TAR file.
user@host> tar xvzf junos-vmhost-install-ptx-x86-64-xyz.tgz ­C /var/tmp attributes junos-vmhost-install-ptx.tgz manifest manifest.certs manifest.ecerts manifest.esig manifest.sig package.xml pkg_add_vmhost.sh vmhost-install-net-x86_64-xyz.tgz
4. Remove the previously installed files, if any, from the /tftpboot directory.
user@host> rm -f /tftpboot user@host>mkdir /tftpboot
5. Extract the network installation package.
user@host> tar xvzf /var/tmp/junos-vmhost-install-ptx-x86-64-xyz.tgz -C /tftpboot/ ./ ./vmhost-version.sh ./bootpxe64.efi ./vmhost-version ./grub.cfg .. ... -rw-rw-r-- 1 930 930 45M Oct 20 01:51 vmhost-install-net-x86_64-xyz.tgz -rw-rw-r-- 1 930 930 6 Oct 20 01:51 vmhost-version -rwxrwxr-x 1 930 930 416 Oct 20 01:51 vmhost-version.sh

217
-rw-r--r-- 1 930 930 6.9M Oct 20 01:51 vmlinuz
6. Rename or delete the previously installed root file system/scripts from the /var/install directory. Create a new /var/install directory.
user@host>mv /var/install /var/install_old user@host>mkdir /var/install
7. Extract the installation package.
user@host>tar xvzf /var/tmp/junos-vmhost-install-ptx-x86-64.tgz -C /var/install ./ ./vmhost-pkgs-version ./vm/ ./vm/note ./vm/grub.cfg.ngre ./vm/vsmartd-1.0-0.x86_64.rpm ./vm/re_fpga-1.0-0.x86_64.rpm ./vm/veccd-1.0-0.x86_64.rpm ./vmhost-version.sh ./vmhost/ ./vmhost/vmhost-x86_64-xyz.img.gz ... ... ./junos/junos-mtre-upgrade.sh ./vmhost-core-x86_64-15.1I20151019_1021_builder.tgz ./junos/ ./junos/junos-install-x86-64-xyz.img.gz
8. Verify that the /var/install folder contains the attributes file. If the file does not exist in the specified location, copy the attribute file.
NOTE: The attribute file consists of the personality information of the image. If the attributes file is not present, the device is unable to upgrade to the new personality even when the PXE boot server has the relevant image.
user@host> mv /var/tmp/attributes /var/install

218
9. Set permissions for the files in the /var/install and /tftpboot directories.
user@host> chown root:root /tftpboot/* user@host>chmod a+rwx /tftpboot/* user@host>chown -R root:root /var/install user@host>chmod -R a+rwx /var/install 10. Exit the PXE boot server.
user@host> exit
After you copy the image to the PXE Boot Server, to install the image on the device, reboot the device to install the image. You can use the request vmhost reboot network command to install the image. The device boots from the PXE server and installs the image on both the SSDs. However, if the device fails to reboot, you can use the USB disk installation option. If the device fails to reboot or is not accessible, follow these steps: 1. Power cycle the device. 2. Press the ESC button to go to the Boot Manager Menu. 3. Select Boot Manager, and then press Enter. 4. Select ETH00 (xx:xx:xx:xx:xx:xx) option. A warning message is displayed. At the prompt, select y to
install the image on both the primary and secondary disks.
WARNING: The installation will erase the contents of your disks. Install vmhost and Junos Software on Primary and Secondary disk [y/n] y
5. In operational mode, verify that the upgrade is successful.
user@host> show version Hostname: host Model: ptx10002-60C
NOTE: Juniper Networks does not support using the request vmhost software rollback command to revert to the previously installed personality.

219
Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the USB Option
You can configure your QFX10002-60C device as a PTX10002-60C device or your PTX10002-60C device as a QFX10002-60C device. The image loaded on the device determines the personality of the device. For example, if you have purchased a QFX10002-60C device, the installed personality is a QFX10002-60C device. When you upgrade the QFX10002-60C device to a PTX10002-60C device, the new personality of the device is a PTX10002-60 C device. Similarly, if you have purchased a PTX10002-60C device, the installed personality is a PTX10002-60C device and the new personality, if you upgrade, is a QFX10002-60C device. In an USB upgrade, the content of the SSDs are erased and the image is installed from the USB to both the primary and secondary disks. Based on the image used, the device comes up as either a QFX10002-60C or a PTX10002-60C device. This is irrespective of the previously installed personality of the JNP10002-60C-CHAS chassis.
NOTE: When you order the spare JNP10002-60C-CHAS, it is preloaded with the QFX10002-60C and PTX10002-60C software images in the /var/tmp location. If you want to convert a QFX10002-60C device to a PTX10002-60C device, use the PTX10002-60C image. If you want to convert a PTX10002-60C device to QFX10002-60C device, use the QFX10002-60C image.
For example, to upgrade the QFX10002-60C device from the installed personality of QFX10002-60C to the new personality of PTX10002-60C device using the USB Option: 1. Insert the external USB flash drive. The external flash drive is detected. 2. Reboot the device.
user@host# run request vmhost reboot usb OR user@host# run request vmhost reboot
3. Unplug the USB flash drive after the system reboots, when prompted.
NOTE: Juniper Networks does not support using the request vmhost software rollback command to revert to the previously installed personality.

220
Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using the CLI Option
You can configure your QFX10002-60C device as a PTX10002-60C device or your PTX10002-60C device as a QFX10002-60C device. The image loaded on the device determines the personality of the device. For example, if you have purchased a QFX10002-60C device, the installed personality is a QFX10002-60C device. When you upgrade the QFX10002-60C device to a PTX10002-60C device, the new personality of the device is a PTX10002-60C device. Similarly, if you have purchased a PTX10002-60C device, the installed personality is PTX10002-60C and the new personality, if you upgrade, is a QFX10002-60C device.
NOTE: When you upgrade the QFX10002-60C personality to a PTX10002-60C personality, the QFX10002-60C default configuration is deleted, and the PTX10002-60C configuration becomes the default configuration. When you upgrade the PTX10002-60C personality to a QFX10002-60C personality, the PTX10002-60C default configuration is deleted, and the QFX10002-60C configuration becomes the default configuration. Additionally, the software snapshot in the secondary disk is deleted, and the new software snapshot is installed in the secondary disk. For example, if you upgrade the QFX10002-60C personality to a PTX10002-60C personality, the QFX10002-60C snapshot is deleted, and the PTX10002-60C snapshot is installed in the secondary disk.
NOTE: When you order the spare JNP10002-60C-CHAS, it is preloaded with the QFX10002-60C and PTX10002-60C software images in the /var/tmp location. If you want to convert a QFX10002-60C device to a PTX10002-60C device, use the PTX10002-60C image. If you want to convert a PTX10002-60C device to QFX10002-60C device, use the QFX10002-60C image.
· Verify if the installed image supports the required command to upgrade to the new personality. If it does not, upgrade to a later version of the image before you upgrade to the new personality.
· Delete any configuration that is not supported or not compatible with the new personality before you upgrade the personality. If any unsupported configuration is retained in the device after it reboots with the new image, the device returns to the factory-default configuration.
For example, to upgrade the QFX10002-60C device from the installed personality of QFX10002-60C to the new personality of PTX10002-60C device using the CLI Option:

221
1. In operational mode, verify the installed personality of the device
user@host> show version
Hostname: host Model: QFX10002-60C 2. Download the software package from https://www.juniper.net/support/. For information about downloading software packages, see "Downloading Software" on page 107. Save the software
package to the /var/path/package-name directory on the device. For example, you can save the software package to the /var/tmp directory.
NOTE: Download the software package specific to the personality you want to upgrade to. The software package for QFX Series devices is different from the software package for the PTX Series devices.
3. In operational mode, install the software package by using the request vmhost software add path/ package-name command. For example, to install the junos-vmhost-install-ptx-x86-64-zyx.tgz package:
user@host> request vmhost software add /var/tmp/junos-vmhost-install-ptxx86-64-zyx.tgz no-validate
NOTE: If you do not specify the no-validate option, the device displays the following error message error: Upgrading to a different model is supported only with no-validate option .
4. Run the show version command to verify that the upgrade is successful.
user@host> show version
Hostname: host Model: ptx10002-60C

222
NOTE: Juniper Networks does not support using the request vmhost software rollback command to revert to the previously installed personality.
To ensure that all 4 partitions are upgraded to the same personality, follow these steps: 1. Boot from solid-state drive (SSD) Disk 2 using the request vmhost reboot command.
user@host>request vmhost reboot disk2
2. Upgrade to the new personality using no-validate option. This command upgrades both partitions on SSD Disk 1.
user@host> request vmhost software add package-name no-validate reboot For example:
user@host> request vmhost software add junos-vmhost-install-ptx-x86-64zyx.tgz no-validate reboot If you are upgrading to the PTX10002-60C device, include the package for the PTX10002-60C device. If you are upgrading to the QFX10002-60C device, include the package for the QFX10002-60C device. 3. After booting up from SSD1, take a snapshot from SSD1 to SSD2.
user@host>request vmhost snapshot partition This ensures that both partitions on SSD2 are upgraded to new personality.
Upgrading the Personality of QFX10002-60C and PTX10002-60C Devices Using Zero Touch Provisioning (ZTP)
You can configure your QFX10002-60C device as a PTX10002-60C device or your PTX10002-60C device as a QFX10002-60C device. The image loaded on the device determines the personality of the device. For example, if you have purchased a QFX10002-60C device, the installed personality is a

223
QFX10002-60C device. When you upgrade the QFX10002-60C device to a PTX10002-60C device, the new personality of the device is a PTX10002-60C device. Similarly, if you have purchased a PTX10002-60C device, the installed personality is PTX10002-60C and the new personality, if you upgrade, is a QFX10002-60C device.
NOTE: When you upgrade the QFX10002-60C personality to a PTX10002-60C personality, the QFX10002-60C default configuration is deleted, and the PTX10002-60C configuration becomes the default configuration. When you upgrade the PTX10002-60C personality to a QFX10002-60C personality, the PTX10002-60C default configuration is deleted, and the QFX10002-60C configuration becomes the default configuration. If you have provided your own Junos OS configuration, that configuration becomes the default configuration. Additionally, the software snapshot in the secondary disk is deleted, and the new software snapshot is installed in the secondary disk. For example, if you upgrade the QFX10002-60C personality to a PTX10002-60C personality, the QFX10002-60C snapshot is deleted, and the PTX10002-60C snapshot is installed in the secondary disk.
NOTE: When you order the spare JNP10002-60C-CHAS, it is preloaded with the QFX10002-60C and PTX10002-60C software images in the /var/tmp location. If you want to convert a QFX10002-60C device to a PTX10002-60C device, use the PTX10002-60C image. If you want to convert a PTX10002-60C device to QFX10002-60C device, use the QFX10002-60C image.
· Verify if the installed image supports the required command to upgrade to the new personality. If it does not, upgrade to a later version of the image before you upgrade to the new personality.
· Delete any configuration that is not supported or not compatible with the new personality before you upgrade the personality. If any unsupported configuration is retained in the device after it reboots with the new image, the device returns to the factory-default configuration.
Before you begin:
· Ensure that the switch or router has access to the following network resources:
· The DHCP server that provides the location of the software image and configuration files on the network
Refer to your DHCP server documentation for configuration instructions.
· The File Transfer Protocol (anonymous FTP), Hypertext Transfer Protocol (HTTP), or Trivial File Transfer Protocol (TFTP) server on which the software image and configuration files are stored

224
NOTE: Although TFTP is supported, we recommend that you use FTP or HTTP instead, because these transport protocols are more reliable.
CAUTION: HTTP URLs are limited to 256 characters in length.
· A Domain Name System (DNS) server to perform reverse DNS lookup · (Optional) An NTP server to perform time synchronization on the network · (Optional) A system log (syslog) server to manage system log messages and alerts · Locate and record the MAC address printed on the switch or router chassis.
CAUTION: You cannot commit a configuration while the switch or router is performing the software update process. If you commit a configuration while the switch or router is performing the configuration file autoinstallation process, the process stops, and the configuration file is not downloaded from the network.
For example, to upgrade the QFX10002-60C device from the installed personality of QFX10002-60C to the new personality of PTX10002-60C device using ZTP: 1. In operational mode, verify the installed personality of the device
user@host> show version
Hostname: host Model: QFX10002-60C 2. Boot the device. 3. Make sure the device has the default factory configuration installed. Issue the request vmhost zeroize command on the device that you want to provision. 4. Download the software package specific to the personality you want to upgrade from https:// www.juniper.net/support/. The software package for QFX Series devices is different from the software package for the PTX Series devices. 5. Save the software package and the configuration file to the FTP, HTTP, or TFTP server from which the device will download these files.

225
6. Configure the DHCP server to provide the necessary information to the switch or router. Configure IP address assignment. You can configure dynamic or static IP address assignment for the management address of the switch or router. To determine the management MAC address for static IP address mapping, add 1 to the last byte of the MAC address of the switch or router, which you noted before you began this procedure.
7. Define the format of the vendor-specific information for DHCP option 43 in the dhcpd.conf file. Here is an example of an ISC DHCP 4.2 server dhcpd.conf file:
option space NEW_OP; option; option NEW_OP.image-file-name code 0 = text; option NEW_OP.config-file-name code 1 = text; option NEW_OP.image-file-type code 2 = text; option NEW_OP.transfer-mode code 3 = text; option NEW_OP.alt-image-file-name code 4= text; option NEW_OP.jloader-file code 5 = text; option NEW_OP-encapsulation code 43 = encapsulate NEW_OP;
NOTE: Starting in Junos OS Release 18.2R1, a new DHCP option is introduced to set the timeout value for the file downloads over FTP. If the transfer-mode is set as FTP, the default value for the timeout is automatically set as 120 minutes, that is, in case the FTP session gets interrupted due to loss of connectivity in the middle of a file transfer, it will timeout after 120 minutes and ZTP will attempt to retry the file fetching process. This value can be overridden using the DHCP option as follows:
option NEW_OP.ftp-timeout code 7 = text; option NEW_OP.ftp-timeout "val";
where "val" is the user configurable timeout value in seconds and must be provided within quotes (like, "val").
8. Configure the following DHCP option 43 suboptions:
NOTE: DHCP option 43 suboptions 05 through 255 are reserved.
· Suboption 00: The name of the software image file to install.

226
NOTE: When the DHCP server cannot use suboption 00, configure the software image filename using suboption 04. If both suboption 00 and suboption 4 are defined, suboption 04 is ignored.
option NEW_OP.image-file-name "/dist/images/jinstall-ex-4200-13.2R1.1-domestic-signed.tgz";
· Suboption 01: The name of the script or configuration file to install.
option NEW_OP.config-file-name "/dist/config/jn-switch35.config"; The following list provides the types of scripts and their associated interpreter paths: · Shell script interpreter path: #!/bin/sh · SLAX script interpreter path: #!/usr/libexec/ui/cscript · Python script interpreter path: #!/usr/bin/python
Unsigned Python scripts are only supported on limited platforms, such as the QFX5100 device. If you try to execute unsigned Python scripts on devices that do not provide support, error messages will be issued.
NOTE: If the file does not contain special characters (#!) , ZTP determines that the file is a configuration file and loads the configuration file.
· Suboption 02: The symbolic link to the software image file to install.
option NEW_OP.image-file-type "symlink";
NOTE: If you do not specify suboption 2, the ZTP process handles the software image as a filename, not a symbolic link.

227
· Suboption 03: The transfer mode that the switch or router uses to access the TFTP, FTP, or HTTP server. If you select FTP as the transfer mode, Junos OS uses the anonymous FTP login to download files from the FTP server.
option NEW_OP.transfer-mode "ftp";
NOTE: If suboption 03 is not configured, TFTP becomes the transfer mode by default.
· Suboption 04: The name of the software image file to install.
NOTE: When the DHCP server cannot use suboption 00, configure the image file using suboption 04. If both suboption 00 and suboption 4 are defined, suboption 04 is ignored.
option NEW_OP.alt-image-file-name "/dist/images/jinstall-ex-4200-13.2R1.1-domestic-signed.tgz"; · Suboption 05: The name of the JLoader image file to install.
NEW_OP.jloader-file "jloader-qfx-5-14.1X53-D26-signed.tgz"; 9. (Mandatory) Configure either option 150 or option 66.
NOTE: You must configure either option 150 or option 66. If you configure both option 150 and option 66, option 150 takes precedence, and option 66 is ignored. Also, make sure you specify an IP address, not a hostname, because name resolution is not supported.
· Configure DHCP option 150 to specify the IP address of the FTP, HTTP, or TFTP server.
option option-150 code 150={ip-address}; option option-150 10.100.31.71; · Configure DHCP option 66 to specify the IP address of the FTP, HTTP, or TFTP server.
option tftp-server-name "10.100.31.71";

228
10. (Optional) Configure DHCP option 7 to specify one or more system log (syslog) servers.
option log-servers 10.100.31.72;
11. (Optional) Configure DHCP option 42 to specify one or more NTP servers.
option ntp-servers 10.100.31.73;
12. (Optional) Configure DHCP option 12 to specify the hostname of the switch or router.
option hostname "jn-switch35";
The following sample configuration shows the DHCP options you just configured:
host jn-switch35 { hardware ethernet ac:4b:c8:29:5d:02; fixed-address 10.100.31.36;
option tftp-server-name "10.100.31.71";
option host-name "jn-switch35"; option log-servers 10.100.31.72; option ntp-servers 10.100.31.73; option NEW_OP.image-file-name "/dist/images/jinstall-ex-4200-13.2R1.1domestic-signed.tgz"; option NEW_OP.transfer-mode "ftp"; option NEW_OP.config-file-name "/dist/config/jn-switch35.config"; option NEW_OP.jloader-file "jloader-qfx-5-14.1X53-D26-signed.tgz"; }
Based on the DHCP options you just configured, the following statements are appended to the Junos OS configuration file (for example, jn-switch35.config):
system { host-name jn-switch35;
syslog { host 10.100.31.72 { any any;

229
} } ntp {
server 10.100.31.73; } } 13. Monitor the ZTP process by looking at the following log files.
NOTE: When SLAX (live operating system based on Linux) scripts are issued, the opscript.log and event-script.log files are produced.
· /var/log/dhcp_logfile · /var/log/event-script.log · /var/log/image_load_log · /var/log/messages · /var/log/op-script.log · /var/log/script_output You can also monitor the ZTP process by looking at error messages and issuing operational commands. See "Monitoring Zero Touch Provisioning" on page 438 for more information. 14. Run the show version command to verify that the upgrade is successful.
user@host> show version
Hostname: host Model: ptx10002-60C

230
Upgrade the NFX250 Software to NFX250 NextGen Software
IN THIS SECTION NFX250 NextGen Software Upgrade Overview | 230 Prerequisites | 230 Upgrade to NFX250 NextGen Software Architecture | 233
NFX250 NextGen Software Upgrade Overview
Starting in Junos OS Release 19.1R1, the NFX250 devices support the NFX250 NextGen software architecture. This is a re-optimized architecture that enables you to use JCP as the single point of management to manage all the NFX250 components. For more information about the NFX250 NextGen architecture, see NFX250 NextGen Overview.
NOTE: For documentation purposes, NFX250 devices that use the reoptimized architecture are referred to as NFX250 NextGen devices.
You can upgrade the software using a USB or through a CLI. This topic provides information about prerequisites and the procedure to upgrade through a CLI from NFX250 software architecture to NFX250 NextGen software architecture.
NOTE: The upgrade procedure using a USB remains the same for all NFX Series devices.
Prerequisites
To upgrade an NFX250 device, you must meet the following prerequisites: Device-specific prerequisites

231

· An NFX250 device with BIOS => CBDE_SFP_00.21_01.01 To verify the BIOS version:

root@jdm> request execute-command "jhost dmidecode -t bios"
For the BIOS information, see the BIOS Information section in the command output message. If the BIOS version is not CBDE_SFP_00.21_01.01, you can upgrade the BIOS: 1. Download the BIOS from Downloads page. 2. Copy and save the BIOS image to the /var/third-party directory. 3. From the JDM CLI, access the hypervisor:

root@jdm> ssh hypervisor 4. Upgrade the BIOS:

root@host:~# rpm -ivh /var/third-party/firmware/BIOS RPM package name The system generates the following output:

Preparing...

########################################### [100%]

1:nfx-2-secure-bios

########################################### [100%]

A reboot is required to install the secure BIOS

Please reboot the system to complete the install

5. Reboot the device to load new BIOS. a. Exit from hypervisor shell:

root@local-node:~# exit logout Connection to hypervisor closed. {master:0} root@JDM>

232
b. Reboot the device from JDM CLI.
{master:0} root@porter-p2a-sys1> request system reboot Reboot the system ? [yes,no] (no) yes
· An NFX250 NextGen configuration file with minimal or necessary configurations is required for remote management access to the device after migrating to NFX250 NextGen. This file is an input data for the request system software add clean-install package-name command.
Release-specific prerequisites The NFX250 software must be compatible with the following releases: · NFX250 software running Junos OS Release 18.4R2 or later to accept the configuration by using the
command:
user@host> request system software add clean-install package-name
CAUTION: The clean-install command removes all contents on the hard disk. To avoid data loss, copy all important files, configuration files (JDM, JCP, vSRX, and third-party VNFs), log files, and VNF disk or image file, and save them in a secure location before you upgrade the device.
· Releases prior to 18.4R2 must be upgraded to 18.4R2 or later.
CAUTION: The NFX250 device will crash if you upgrade the NFX250 software image running Junos OS Release prior to 18.4R2 to a release that supports NFX250 NextGen software image. The NFX250 NextGen configuration must be compatible with the NFX250 NextGen software version. The configuration command syntax is not validated.
NOTE: The NFX250 software architecture and NFX250 NextGen software architecture are different and the configurations are different for both the software.

233
Upgrade to NFX250 NextGen Software Architecture
Before you upgrade the NFX device: · Create backup of the configuration files (JDM, JCP, vSRX, and third-party VNFs), log files, VNF disk
or image file, and other important files stored on the device. · Check the prerequisites. To upgrade the NFX250 software architecture to NFX250 NextGen software architecture: 1. Copy the configuration files that are required for in-band and out-of-band management and save it in
the /var/third-party folder. The configuration file should be of the same format as the file format obtained by running the show configuration CLI command. 2. Copy the NFX250 NextGen software image and save it in the /var/third-party/images folder. 3. Initiate the software upgrade by using the following command:
root@jdm> request system software add clean-install reboot /var/third-party/ images/jinstall-image.tgz upgrade-with-config /var/third-party/config-file
The device is formatted and the NFX250 NextGen software image is installed. The device loads the configurations and boots up the NFX250 Nextgen software image. You can access the device remotely through the in-band and out-of-band management. 4. The device is now ready for additional configurations and third-party VNF onboarding.
Installing Software on SRX Series Devices
IN THIS SECTION Understanding Junos OS Upgrades for SRX Series Devices | 234 Example: Installing Junos OS Upgrade Packages on SRX Series Devices | 236 Example: Installing Junos OS on SRX Series Devices Using the Partition Option | 240 Reverting the Junos OS Software Image Back to the Previous Version | 245 Preparing the USB Flash Drive to Upgrade Junos OS on SRX Series Devices | 248 Installing Junos OS on SRX Series Devices Using a USB Flash Drive | 250

234
Upgrading the Boot Loader on SRX Series Devices | 251 Installing Junos OS on SRX Series Devices from the Boot Loader Using a TFTP Server | 252 Installing Junos OS on SRX Series Devices from the Boot Loader Using a USB Storage Device | 255 Restarting and Halting SRX Series Devices | 256
SRX Series devices are delivered with preinstalled Junos operating system (Junos OS). Before you start this procedure, decide which software package you need and download it. For information on which packages to use for which upgrades, see "Junos OS and Junos OS Evolved Installation Package Names" on page 69.
Understanding Junos OS Upgrades for SRX Series Devices
IN THIS SECTION Understanding Junos OS Upgrades | 234 Junos OS Upgrade Methods on the SRX Series Devices | 235
SRX Series devices are delivered with Junos OS pre-installed on them. When you power on a device, it starts (boots) up using its primary boot device. These devices also support secondary boot devices, allowing you to back up your primary boot device and configuration. As new features and software fixes become available, you must upgrade Junos OS to use them. Before an upgrade, we recommend that you back up your primary boot device.
Understanding Junos OS Upgrades
On a services gateway, you can configure the primary or secondary boot device with a snapshot of the current configuration, default factory configuration, or rescue configuration. You can also replicate the configuration for use on another device. If the SRX Series device does not have a secondary boot device configured and the primary boot device becomes corrupted, you can reload the Junos OS package onto the corrupted internal media from a USB flash drive or TFTP server.

235
Junos OS Upgrade Methods on the SRX Series Devices
SRX Series devices that ship from the factory with Junos OS Release 10.0 or later are formatted with the dual-root partitioning scheme.
NOTE: Junos OS Release 12.1X45 and later do not support single root partitioning.
NOTE: SRX100, SRX110, SRX210, SRX220, and SRX240 devices with 2 GB RAM cannot be upgraded to any Junos OS 12.1X46 Release after 12.1X46-D65. Attempting to upgrade to this release on devices with 2 GB RAM will trigger the following error: ERROR: Unsupported platform for 12.1X46 releases after 12.1X46-D65 .
Existing SRX Series devices that are running Junos OS Release 9.6 or earlier use the single-root partitioning scheme. While upgrading these devices to Junos OS Release 10.0 or later, you can choose to format the storage media with dual-root partitioning (strongly recommended) or retain the existing single-root partitioning. Certain Junos OS upgrade methods format the internal media before installation, whereas other methods do not. To install Junos OS Release 10.0 or later with the dual-root partitioning scheme, you must use an upgrade method that formats the internal media before installation.
NOTE: If you are upgrading to Junos OS Release 10.0 without transitioning to dual-root partitioning, use the conventional CLI and J-Web user interface installation methods.
These upgrade methods format the internal media before installation: · Installation from the boot loader using a TFTP server · Installation from the boot loader using a USB storage device · Installation from the CLI using the partition option (available in Junos OS Release 10.0) · Installation using the J-Web user interface These upgrade methods retain the existing partitioning scheme: · Installation using the CLI · Installation using the J-Web user interface

236
CAUTION: Upgrade methods that format the internal media before installation wipe out the existing contents of the media. Only the current configuration is preserved. Any important data must be backed up before starting the process.
NOTE: Once the media has been formatted with the dual-root partitioning scheme, you can use conventional CLI or J-Web user interface installation methods, which retain the existing partitioning and contents of the media, for subsequent upgrades.
Example: Installing Junos OS Upgrade Packages on SRX Series Devices
IN THIS SECTION Requirements | 236 Overview | 237 Configuration | 237 Verification | 239
This example shows how to install Junos OS upgrades on SRX Series devices.
Requirements
Before you begin: · Verify the available space on the internal media. · Download the software package. See Downloads to download the software package for your
products. · Copy the software package to the device if you are installing the software package from a local
directory on the device. We recommend that you copy it to the /var/tmp directory. To copy the software package to the /var/tmp directory, use the following command from the operational mode:
user@host> file copy /var/tmp/install/image-name/var/tmp/

237
Example:
user@host> file copy /var/tmp/install/junos-srxsme-10.0R2-domestic.tgz /var/tmp/
Overview
By default, the request system software add package-name command uses the validate option to validate the software package against the current configuration as a prerequisite to adding the software package. This validation ensures that the device can reboot successfully after the software package is installed. This is the default behavior when you are adding a software package. In this example, add the software package (for example: junos-srxsme-10.0R2-domestic.tgz [for SRX Series devices] with the following options: · no-copy option to install the software package but do not save the copies of package files. You must
include this option if you do not have enough space on the internal media to perform an upgrade that keeps a copy of the package on the device. · reboot option to reboots the device after installation is completed.
Configuration
IN THIS SECTION Procedure | 237
Procedure
GUI Quick Configuration
Step-by-Step Procedure To install Junos OS upgrades on SRX Series devices: 1. In the J-Web user interface, select Maintain>Software>Upload Package. 2. On the Upload Package page, specify the software package to upload. Click Browse to navigate to
the software package location and select junos-srxsme-10.0R2-domestic.tgz. 3. Select the Reboot If Required check box to set the device to reboot automatically when the upgrade
is complete.

238
4. Select the Do not save backup check box to bypass saving the backup copy of the current Junos OS package (SRX Series).
5. Click Upload Package. The software is activated after the device has rebooted. 6. Click OK to check your configuration and save it as a candidate configuration. 7. If you are done configuring the device, click Commit Options>Commit.
Step-by-Step Procedure The following example requires you to navigate various levels in the configuration hierarchy. For instructions on how to do that, see Using the CLI Editor in Configuration Mode. From operational mode, install the new package on the device with the no-copy option, and format and re-partition the media before installation, and reboot the device after installation is completed. To install Junos OS upgrades on SRX Series devices: 1. From operational mode, install the new package on the device. In this example, the package name is
junos-srxsme-10.0R2-domestic.tgz:
user@host> request system software add /var/tmp/junos-srxsme-10.0R2-domestic.tgz no-copy
NOTE: We recommend that you configure the no-validate option only when expressly specified by the Juniper Networks Technical Assistance Center (JTAC).
2. Reboot the device.
user@host> request system reboot
When the reboot is complete, the device displays the login prompt.
Results From configuration mode, confirm your configuration by entering the show system command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it. If you are done configuring the device, enter commit from configuration mode.

239
Verification
IN THIS SECTION Verifying the Junos OS Upgrade Installation | 239
Confirm that the configuration is working properly. Verifying the Junos OS Upgrade Installation Purpose Verify that the Junos OS upgrade was installed. Action From operational mode, enter the show version command. Sample Output command-name
user@host> show version Hostname: srx340-a Model: srx345 Junos: 18.2R1-S3.2 JUNOS Software Release [18.2R1-S3.2]
Meaning The show version command displays the hostname, model number, and the release information loaded on the device.

240
Example: Installing Junos OS on SRX Series Devices Using the Partition Option
IN THIS SECTION Requirements | 240 Overview | 240 Configuration | 241 Verification | 244
This example shows how to install Junos OS Release 10.0 or later with the partition option.
Requirements
Before you begin, back up any important data.
Overview
IN THIS SECTION Topology | 241
This example formats the internal media and installs the new Junos OS image on the media with dualroot partitioning. Reinstall the Release 10.0 or later image from the CLI using the request system software add command with the partition option. This copies the image to the device, and then reboots the device for installation. The device boots up with the Release 10.0 or later image installed with the dual-root partitioning scheme. When the partition option is used, the format and install process is scheduled to run on the next reboot. Therefore, we recommend that this option be used together with the reboot option.
NOTE: The process might take 15 to 20 minutes. The system is not accessible over the network during this time.

241
CAUTION: Using the partition option with the request system software add command erases the existing contents of the media. Only the current configuration is preserved. You must back up any important data before starting the process.
NOTE: Partition install is supported on the default media on SRX300, SRX320, SRX340, and SRX345 devices (internal NAND flash) and not supported on the alternate media (USB storage key). Partition install is supported on the default media on SRX380 Series devices (internal SSD) and not on alternate media (USB storage key).
NOTE: Partition install is supported on the default media on SRX100, SRX210, and SRX240 devices (internal NAND flash) and on SRX650 devices (internal CF card). Partition install is not supported on the alternate media on SRX100, SRX210, and SRX240 devices (USB storage key) or on SRX650 devices (external CF card or USB storage key).
In this example, add the software package junos-srxsme-10.0R2-domestic.tgz with the following options: · no-copy option to install the software package but do not save the copies of package files. You must
include this option if you do not have enough space on the internal media to perform an upgrade that keeps a copy of the package on the device. · no-validate option to bypass the compatibility check with the current configuration before installation starts. · partition option to format and re-partition the media before installation. · reboot option to reboots the device after installation is completed.
Topology
Configuration
IN THIS SECTION Procedure | 242

242
Procedure
CLI Quick Configuration
To install Junos OS Release 10.0 or later with the partition option, enter the following command from operational mode:
user@host>request system software add junos-srxsme-10.0R2-domestic.tgz no-copy no-validate partition reboot
GUI Quick Configuration
Step-by-Step Procedure
To install Junos OS Release 10.0 or later with the partition option: 1. In the J-Web user interface, select Maintain>Software>Install Package. 2. On the Install Package page, specify the FTP or HTTP server, file path, and software package name.
Type the full address of the software package location on the FTP or HTTP. Example: ftp:// hostname/pathname/junos-srxsme-xx.0R2-domestic.tgz or http://hostname/pathname/junossrxsme-xx.0R2-domestic.tgz.
NOTE: Specify the username and password, if the server requires one.
3. Select the Reboot If Required check box to set the device to reboot automatically when the upgrade is complete.
4. Select the Do not save backup check box to bypass saving the backup copy of the current Junos OS package.
5. Select the Format and re-partition the media before installation check box to format the internal media with dual-root partitioning.
6. Click Fetch and Install Package. The software is activated after the device reboots. This formats the internal media and installs the new Junos OS image on the media with dual-root partitioning.

243
Step-by-Step Procedure
The following example requires you to navigate various levels in the configuration hierarchy. For instructions on how to do that, see Using the CLI Editor in Configuration Mode. To install Junos OS Release 10.0 or later with the partition option: 1. Upgrade the device to Junos OS Release 10.0 or later using the CLI. 2. After the device reboots, upgrade the boot loader to the latest version. See Preparing the USB Flash
Drive to Upgrade Junos OS on SRX Series Devices. 3. Reinstall the Release 10.0 or later image.
user@host>request system software add junos-srxsme-10.0R2-domestic.tgz no-copy no-validate partition reboot Copying package junos-srxsme-10.0R2-domestic.tgz to var/tmp/install Rebooting ...
Results
From configuration mode, confirm your configuration by entering the show system storage partitions command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it. Sample output on a system with single root partitioning:
user@host> show system storage partitions
Boot Media: internal (da0)
Partitions Information: Partition Size Mountpoint s1a 898M / s1e 24M /config s1f 61M /var

244
Sample output on a system with dual-root partitioning:
user@host> show system storage partitions
Boot Media: internal (da0) Active Partition: da0s2a Backup Partition: da0s1a Currently booted from: active (da0s2a) Partitions Information:
Partition Size Mountpoint s1a 293M altroot s2a 293M / s3e 24M /config s3f 342M /var s4a 30M recovery
If you are done configuring the device, enter commit from configuration mode.
Verification
IN THIS SECTION Verifying the Partitioning Scheme Details | 244
Confirm that the configuration is working properly. Verifying the Partitioning Scheme Details Purpose Verify that the partitioning scheme details on the SRX Series device were configured. Action From operational mode, enter the show system storage partitions command.

245
SEE ALSO Configuring Root Partitions on SRX Series Devices
Reverting the Junos OS Software Image Back to the Previous Version
IN THIS SECTION Requirements | 245 Overview | 245 Configuration | 246 Verification | 247
This example shows how to downgrade Junos OS on the SRX Series devices.
Requirements
No special configuration beyond device initialization is required before configuring this feature.
Overview
When you upgrade your software, the device creates a backup image of the software that was previously installed in addition to installing the requested software upgrade. To downgrade the software, you can revert to the previous image using the backup image. You can use this method to downgrade to only the software release that was installed on the device before the current release. To downgrade to an earlier version, follow the procedure for upgrading, using the software image labeled with the appropriate release. This example returns software to the previous Junos OS version.
NOTE: This procedure applies only to downgrading from one Junos OS software release to another or from one Junos OS services release to another.

246
Configuration
IN THIS SECTION Procedure | 246
Procedure CLI Quick Configuration To quickly configure this section of the example, copy the following commands, paste them into a text file, remove any line breaks, change any details necessary to match your network configuration, copy and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode. From operational mode, enter:
user@host> request system software rollback request system reboot
GUI Quick Configuration Step-by-Step Procedure To downgrade Junos OS on SRX Series devices: 1. In the J-Web user interface, select Maintain>Software>Downgrade. The image of the previous
version (if any) appears on this page.
NOTE: After you perform this operation, you cannot undo it.
2. Select Downgrade to downgrade to the previous version of the software or Cancel to cancel the downgrade process.
3. Click Maintain>Reboot from the J-Web user interface to reboot the device.

247
NOTE: To downgrade to an earlier version, follow the procedure for upgrading, using the software image labeled with the appropriate release.
4. Click OK to check your configuration and save it as a candidate configuration. 5. If you are done configuring the device, click Commit Options>Commit. Step-by-Step Procedure The following example requires you to navigate various levels in the configuration hierarchy. For instructions on how to do that, see Using the CLI Editor in Configuration Mode. To downgrade Junos OS on SRX Series devices: 1. From operational mode, return to the previous Junos OS version.
user@host> request system software rollback
2. Reboot the device.
user@host> request system reboot The device is now running the previous version of Junos OS. To downgrade to an earlier version, follow the procedure for upgrading, using the software image labeled with the appropriate release.
Results From configuration mode, confirm your configuration by entering the show system command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it. If you are done configuring the device, enter commit from configuration mode. Verification
IN THIS SECTION Verifying the Junos OS Downgrade Installation | 248

248
Confirm that the configuration is working properly.
Verifying the Junos OS Downgrade Installation
Purpose Verify that the Junos OS downgrade was installed.
Action From operational mode, enter the show system command.
Preparing the USB Flash Drive to Upgrade Junos OS on SRX Series Devices
This feature simplifies the upgrading of Junos OS images in cases where there is no console access to an SRX Series device located at a remote site. This functionality allows you to upgrade the Junos OS image with minimum configuration effort by simply copying the image onto a USB flash drive, inserting it into the USB port of the SRX Series device, and performing a few simple steps. You can also use this feature to reformat a boot device and recover an SRX Series device after boot media corruption. All USB flash drives used on SRX Series devices must have the following features: · USB 2.0 or later. · Formatted with a FAT/FAT 32 or MS-DOS file system
NOTE: For the list of recommended USB drives, see Knowledge Base article KB31622.
NOTE: The Junos OS package on a USB device is commonly stored in the root drive as the only file; for example, junos-srxsme-15.1X49-D30.3-domestic.tgz.
CAUTION: Any USB memory product not listed as supported for SRX Series devices has not been tested by Juniper Networks. The use of any unsupported USB memory product could expose your SRX Series device to unpredictable behavior. Juniper Networks Technical Assistance Center (JTAC) can provide only limited support for

249
issues related to unsupported hardware. We strongly recommend that you use only supported USB flash drives.
NOTE: This feature is not supported on chassis clusters.
Before you begin: · Copy the Junos OS upgrade image and its autoinstall.conf file to the USB device. · Ensure that adequate space is available on the SRX Series device to install the software image. To prepare the USB flash drive and copy the Junos OS image onto the USB flash drive: 1. Insert the USB flash drive into the USB port of a PC or laptop computer running Windows. 2. From My Computer, right-click the drive Devices with Removable Storage. 3. Format the drive with the FAT/FAT32 file system. 4. Copy the Junos OS image onto the USB device.
For the installation process to succeed, copy only one image onto the USB device. Only images named junos-srxsme* are recognized by the system. 5. Check the drive name detected in My Computer for the USB device. Open the command prompt window and type:
echo " " > <drive-name>:\autoinstall.conf
For example, if the drive detected is drive F, type echo " " > F:\autoinstall.conf at the command prompt. This empty file indicates to the system that the automatic installation of the Junos OS image from the USB device is supported. 6. (Optional) Create a text file named junos-config.conf and copy the file to the USB device. For example, the following file supports an automatic configuration update during the installation process:
system { host-name host-1; domain-name example.net; domain-search [ abc.exmaple.net example.net device1.example.net]; root-authentication { encrypted-password "$ABC123"; ## SECRET-DATA } }

250
... ...
routing-options { static { route 0.0.0.0/0 next-hop 10.207.31.254; }
}
NOTE: The junos-config.conf file is optional, and it is not necessary for the automatic installation of the Junos OS image from the USB device. You can use the junos-config.conf file for a backup configuration for recovery or if the existing configuration is accidentally deleted.
Installing Junos OS on SRX Series Devices Using a USB Flash Drive
To install the Junos OS image on an SRX Series device using a USB flash drive: 1. Insert the USB flash drive into the USB port of the SRX Series device and wait for the LEDs to blink
amber, then steadily turn amber, indicating that the SRX Series device detects the Junos OS image. If the LEDs do not change to amber, press the Power button or turn the device off and then on again and wait for the LEDs to blink amber. 2. Press the Reset Config button on the SRX Series device to start the installation and wait for the LEDs to glow steadily amber. When the LEDs glow green, the Junos OS upgrade image has been successfully installed. If the USB device is plugged in, the Reset Config button always performs as an image upgrade button. Any other functionality of this button is overridden until you remove the USB flash drive. 3. Remove the USB flash drive. The SRX Series device restarts automatically and loads the new Junos OS version.
NOTE: On SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices, frequent plug and play of USB keys is not supported. You must wait for the device node creation before removing the USB key.

251
NOTE: If an installation error occurs, the LEDs turn red, which might indicate that the Junos OS image on the USB flash drive is corrupted. An installation error can also occur if the current configuration on the SRX Series device is not compatible with the new Junos OS version on the USB or if there is not enough space on the SRX Series device to install the image. You must have console access to the SRX Series device to troubleshoot an installation error.
NOTE: You can use the set system autoinstallation usb disable command to prevent the automatic installation from the USB device. After using this command, if you insert the USB device into the USB port of the SRX Series device, the installation process does not work.
NOTE: Installing the Junos OS image using a USB flash drive is supported on SRX100, SRX110, SRX210, SRX220, and SRX240 devices.
Upgrading the Boot Loader on SRX Series Devices
To upgrade the boot loader to the latest version: 1. Upgrade to Junos OS Release 10.0 or later (with or without dual-root support enabled).
The Junos OS 10.0 image contains the latest boot loader binaries in this path: /boot/uboot, /boot/ loader. 2. Enter the shell prompt using the start shell command. 3. Run the following command from the shell prompt: bootupgrade ­u /boot/uboot ­l /boot/loader
NOTE: You can use the following commands to upgrade U-Boot or perform cyclic redundancy check (CRC): · bootupgrade -s -u ­ To upgrade the secondary boot loader. · bootupgrade -c u-boot ­ To check CRC of the boot loader. · bootupgrade -s -c u-boot ­ To check CRC for the secondary boot loader.

252

· bootupgrade -c loader ­ To check CRC for the loader on boot loader. 4. Enter the show system firmware command to check whether the upgrade is successful or not.

root> show system firmware

Part

Type

FPC 1

PIC 0

MLTE_FW

Routing Engine 0 RE BIOS

Routing Engine 0 RE BIOS Backup

Tag Current version

Available Status version

1 17.2.91 0

OK

0 3.8

3.6

OK

1 3.6

3.6

OK

5. For the new version to take effect, you should reboot the system after upgrading the boot loader. You can check the boot loader version number at console output when your device boots up as shown in the following example:
scanning bus 0 for devices... 1 USB Device(s) found scanning usb for storage devices... 1 Storage Device(s) found
FreeBSD/MIPS U-Boot bootstrap loader, Revision 2.10 To verify the (bios) firmware version on the SRX Series device, enter the show chassis routing-engine bios command.
user@host> show chassis routing-engine bios Routing Engine BIOS Version: 1.5
Installing Junos OS on SRX Series Devices from the Boot Loader Using a TFTP Server
You can install Junos OS using the Trivial File Transfer Protocol (TFTP) method. The device is shipped with Junos OS loaded on the primary boot device. During Junos OS installation from the loader, the

253
device retrieves the Junos OS package from a TFTP server. The internal media is then formatted, and the Junos OS image is installed. From the loader installation, you can: · Install Junos OS on the device for the first time. · Recover the system from a file system corruption.
NOTE: Installation from a TFTP server can only be performed using the first onboard Ethernet interface. Installation from the loader-over-TFTP method does not work reliably over slow speeds or large latency networks.
Before you begin, verify that: · You have access to the TFTP server with the Junos OS package to be installed. · That the TFTP server supports BOOTP or DHCP. If the TFTP server does not support BOOTP or
DHCP, you must set the environment variables before performing the installation from the TFTP server. · Functional network connectivity exists between the device and the TFTP server over the first onboard Ethernet interface. To install the Junos OS image on the internal media of the device: 1. To access the U-boot prompt, use the console connection to connect to the device. 2. Reboot the device. The following messages appear:
Clearing DRAM........ done BIST check passed. Net: pic init done (err = 0)octeth0 POST Passed
After this message appears, you see the following prompt:
Press SPACE to abort autoboot in 3 seconds
3. Press the space bar to stop the autoboot process. The => U-boot prompt appears.
4. From the U-boot prompt, configure the environment variables listed in Table 13 on page 254.

254

Table 13: Environment Variables Settings

Environment Variables

Description

gatewayip

IP address of the gateway device

ipaddr

IP address of the SRX Series device

netmask

network mask

serverip

IP address of the TFTP server

This example shows you how to configure the environment variables:

Clearing DRAM........ done BIST check passed. Net: pic init done (err = 0)octeth0 POST Passed Press SPACE to abort autoboot in 3 seconds
=> => setenv ipaddr 198.51.100.15 => setenv netmask 255.255.255.0 => setenv gatewayip 198.51.100.1 => setenv serverip 203.0.113.2 => saveenv
5. Reboot the system using the reset command. 6. To access the loader prompt, use the console connection to connect to the device. 7. Reboot the device.
The following message appears:
Loading /boot/defaults/loader.conf
After this message appears, you see the following prompt:
Hit [Enter] to boot immediately, or space bar for command prompt. 8. Press the space bar to access the loader prompt (loader>).

255
The loader> prompt appears. Enter:
loader> install tftp://203.0.113.2/junos-srxsme-10.0R2-domestic.tgz
NOTE: The URL path is relative to the TFTP server's TFTP root directory, where the URL is tftp://tftp-server-ipaddress/package.
When this command is executed: · The Junos OS package is downloaded from the TFTP server. · The internal media on the system is formatted. · The Junos OS package is installed on the internal media.
NOTE: The Installation from the loader-over-TFTP method installs Junos OS on the internal CF on SRX100, SRX210, SRX220, and SRX240 devices, whereas on SRX650 devices, this method can install Junos OS on the internal or external CF card.
After Junos OS is installed, the device boots from the internal media. Once the system boots up with Junos OS Release 10.0 or later, you must upgrade the U-boot and boot loader immediately.
CAUTION: When you install Junos OS using the loader-over-TFTP method, the media is formatted. The process attempts to save the current configuration. We recommend that you back up all important information on the device before using this process.
Installing Junos OS on SRX Series Devices from the Boot Loader Using a USB Storage Device
To install Junos OS Release 10.0 or later from the boot loader using a USB storage device: 1. Format a USB storage device in MS-DOS format. 2. Copy the Junos OS image onto the USB storage device. 3. Plug the USB storage device into the SRX Series device.

256
4. Stop the device at the loader prompt and issue the following command:
loader> install file:///<image-path-on-usb> An example of a command is as follows:
loader> install file:///junos-srxsme-10.0R2-domestic.tgz This formats the internal media and installs the new Junos OS image on the media with dual-root partitioning. 5. Remove the USB flash drive.
NOTE: On SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices, frequent plug and play of USB keys is not supported. You must wait for the device node creation before removing the USB key.
NOTE: If an installation error occurs, the LEDs turn red, which might indicate that the Junos OS image on the USB flash drive is corrupted. An installation error can also occur if the current configuration on the SRX Series device is not compatible with the new Junos OS version on the USB or if there is not enough space on the SRX Series device to install the image. You must have console access to the SRX Series device to troubleshoot an installation error.
Restarting and Halting SRX Series Devices
IN THIS SECTION Rebooting SRX Series Devices | 257 Halting SRX Series Devices | 260 Bringing Chassis Components Online and Offline on SRX Series Devices | 262 Restarting the Chassis on SRX Series Devices | 263

257
This topic includes the following sections:
Rebooting SRX Series Devices
IN THIS SECTION Requirements | 257 Overview | 257 Configuration | 257 Verification | 259
This example shows how to reboot a SRX Series device. Requirements Before rebooting the device, save and commit any Junos OS updates. Overview This example shows how to reboot a device fifty minutes from when you set the time from the internal media while sending a text message of 'stop' to all system users before the device reboots. Configuration
IN THIS SECTION Procedure | 257
Procedure CLI Quick Configuration To quickly configure this section of the example, copy the following commands, paste them into a text file, remove any line breaks, change any details necessary to match your network configuration, copy

258
and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode. From operational mode, enter:
user@host> request system reboot at 5 in 50 media internal message stop
GUI Quick Configuration
Step-by-Step Procedure
To reboot a device: 1. In the J-Web user interface, select Maintain>Reboot. 2. Select Reboot in 50 minutes to reboot the device fifty minutes from the current time. 3. Select the internal (for SRX Series devices) boot device from the Reboot From Media list. 4. In the Message box, type stop as the message to display to any user on the device before the reboot
occurs. 5. Click Schedule. The J-Web user interface requests confirmation to perform the reboot. 6. Click OK to confirm the operation.
· If the reboot is scheduled to occur immediately, the device reboots. You cannot access J-Web until the device has restarted and the boot sequence is complete. After the reboot is complete, refresh the browser window to display the J-Web login page.
· If the reboot is scheduled to occur in the future, the Reboot page displays the time until reboot. You have the option to cancel the request by clicking Cancel Reboot on the J-Web user interface Reboot page.
7. Click OK to check your configuration and save it as a candidate configuration. 8. If you are done configuring the device, click Commit Options>Commit.
Step-by-Step Procedure
The following example requires you to navigate various levels in the configuration hierarchy. For instructions on how to do that, see Using the CLI Editor in Configuration Mode. To reboot a device:

259
1. From operational mode, schedule a reboot of the device to occur fifty minutes from when you set the time from the internal media while sending a text message of 'stop' to all system users before the device reboots. Enter:
user@host> request system reboot at 5 in 50 media internal message stop
Results From configuration mode, confirm your configuration by entering the show system command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it. If you are done configuring the device, enter commit from configuration mode. Verification
IN THIS SECTION Verifying the Device Reboot | 259
Confirm that the configuration is working properly. Verifying the Device Reboot Purpose Verify that the device rebooted. Action From operational mode, enter the show system command.

260
Halting SRX Series Devices
IN THIS SECTION Requirements | 260 Overview | 260 Configuration | 260 Verification | 262
This example shows how to halt a device. Requirements Before halting the device, save and commit any Junos OS updates. Overview When the device is halted, all software processes stop and you can access the device through the console port only. Reboot the device by pressing any key on the keyboard.
NOTE: If you cannot connect to the device through the console port, shut down the device by pressing and holding the power button on the front panel until the POWER LED turns off. After the device has shut down, you can power on the device by pressing the power button again. The POWER LED turns on during startup and remains steadily green when the device is operating normally.
This example shows how to halt the system and stop software processes on the device immediately. Configuration
IN THIS SECTION Procedure | 261

261
Procedure
CLI Quick Configuration To quickly configure this section of the example, copy the following commands, paste them into a text file, remove any line breaks, change any details necessary to match your network configuration, copy and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode. From operational mode, enter:
user@host>request system halt at now
NOTE: The request system halt command used for halting the system and stopping software processes on the device is not supported on SRX1500, SRX4100, and SRx4200 devices.
GUI Quick Configuration
Step-by-Step Procedure To halt a device immediately: 1. In the J-Web user interface, select Maintain>Reboot. 2. Select Halt Immediately. After the software stops, you can access the device through the console
port only. 3. Click Schedule. The J-Web user interface requests confirmation to halt. 4. Click OK to confirm the operation. If the device halts, all software processes stop and you can access
the device through the console port only. Reboot the device by pressing any key on the keyboard. 5. Click OK to check your configuration and save it as a candidate configuration. 6. If you are done configuring the device, click Commit Options>Commit.
Step-by-Step Procedure The following example requires you to navigate various levels in the configuration hierarchy. For instructions on how to do that, see Using the CLI Editor in Configuration Mode. To halt a device:

262
1. From operational mode, halt the SRX Series device immediately.
user@host> request system halt at now
Results From configuration mode, confirm your configuration by entering the show system command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it. If you are done configuring the device, enter commit from configuration mode. Verification
IN THIS SECTION Verifying the Device Halt | 262
Confirm that the configuration is working properly. Verifying the Device Halt Purpose Verify that the device halted. Action From operational mode, enter the show system command.
Bringing Chassis Components Online and Offline on SRX Series Devices
You can use the request commands to bring chassis components (except Power Entry Modules and fans) online and offline.

263
To bring chassis components online and offline, enter these request chassis commands:
user@host> request chassis <fru> slot <slot#> pic <pic#> online
user@host> request chassis <fru> slot <slot#> pic <pic#> online
Where <fru> in the request chassis command can be any of the following (for SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices): · fpc--Changes the Flexible PIC Concentrator (FPC) status. Where <fru> in the request chassis command can be any of the following (for SRX5800, SRX5600, and SRX5400 devices): · cb--Changes the control board status. · fabric--Changes the fabric status. · fpc--Changes the Flexible PIC Concentrator (FPC) status. · fpm--Changes the craft interface status. · pic--Changes the physical interface card status. · routing-engine--Changes the routing engine status.
NOTE: The request chassis command is not supported for bringing SPCs online and offline.
Example: To bring specific pic and the corresponding fpc slot online, from operational mode enter the following request chassis command:
user@host> request chassis pic pic-slot 1 fpc-slot 1 online
Restarting the Chassis on SRX Series Devices
You can restart the chassis using the restart chassis-control command with the following options: · To restart the process gracefully:
user@host> restart chassis-control gracefully

264

· To restart the process immediately:

user@host> restart chassis-control immediately

· To restart the process softly:

user@host> restart chassis-control soft

Release History Table

Release

Description

12.1X46

SRX100, SRX110, SRX210, SRX220, and SRX240 devices with 2 GB RAM cannot be upgraded to any Junos OS 12.1X46 Release after 12.1X46-D65. Attempting to upgrade to this release on devices with 2 GB RAM will trigger the following error: ERROR: Unsupported platform for 12.1X46 releases after 12.1X46-D65

12.1X45-D10 Junos OS Release 12.1X45 and later do not support single root partitioning

RELATED DOCUMENTATION Backing Up an Installation Using Snapshots | 7
Upgrading and Downgrading to Junos with Upgraded FreeBSD

IN THIS SECTION Upgrading Junos OS with Upgraded FreeBSD | 265 Downgrading from Junos OS with Upgraded FreeBSD | 272

You can upgrade or downgrade Junos OS with upgraded FreeBSD. You can upgrade Junos OS with upgraded FreeBSD from Junos OS based on FreeBSD 6.1 and upgrade between different releases of Junos OS with upgraded FreeBSD.

265
Upgrading Junos OS with Upgraded FreeBSD
IN THIS SECTION Determine Which Package or Packages to Install | 266 Install Junos OS with Upgraded FreeBSD Over Junos OS | 269 Install Junos OS with Upgraded FreeBSD Over Junos OS with Upgraded FreeBSD of a Different Release | 271
NOTE: If you are upgrading or installing Junos OS on a VM host, see Installing, Upgrading, Backing Up, and Recovery of VM Host.
Starting in Junos OS Release 15.1, certain hardware platforms run an upgraded FreeBSD kernel (FreeBSD 10.x or later) instead of FreeBSD 6.1. The information in this section is about upgrading from Junos OS without upgraded FreeBSD (that is, based on FreeBSD 6.1) to Junos OS with upgraded FreeBSD. It does not address upgrading using ISSU. There are certain limitations to using ISSU when upgrading to Junos OS with upgraded FreeBSD. For more information on using ISSU, see Example: Performing a Unified ISSU. When you are upgrading to a different release of Junos OS, you usually use the request system software add validate command. The validate option checks the candidate software against the current configuration of the device to ensure they are compatible. (Validate is the default behavior when the software package being added is a different release.) However, there are circumstances under which you cannot validate the running configuration in this way. One such circumstance is when you are upgrading to Junos OS with upgraded FreeBSD from Junos OS based on FreeBSD 6.1. If you are upgrading between releases that cannot use direct validation, you might have to validate on a different host. It does not matter where that other host is, as long as you can reach it with NETCONF over SSH (see Establishing an SSH Connection for a NETCONF Session). The target system uses the network to contact the other host, run the validation and authentication, and return the result. The following sections contain two procedures and one matrix. The procedures cover (1) upgrading to Junos OS with upgraded FreeBSD from Junos OS based on FreeBSD 6.1 and (2) upgrading between different releases of Junos OS with upgraded FreeBSD. To determine whether you are upgrading between releases that can use direct validation or not, see "Determine Which Package or Packages to Install".

266
NOTE: Before installing software on a device that has one or more custom YANG data models added to it, back up and remove the configuration data corresponding to the custom YANG data models from the active configuration. For more information see Managing YANG Packages and Configurations During a Software Upgrade or Downgrade.
Determine Which Package or Packages to Install
To determine which software package to install to upgrade to Junos OS with upgraded FreeBSD, you will need to consult the Feature Explorer and Table 1. In using Table 1, be aware of the following:
· You can skip no more than two releases when upgrading (or downgrading). That means you can upgrade only to one of the three releases subsequent to your current release. If you want to upgrade across more releases than this, you need to perform multiple upgrades.
· Notice that Table 1 separates its information between security devices and routing or switching devices. This is because security devices have been released on a different release sequence than routing and switching devices, and this in turn determines what constitutes skipping no more than two releases. Whereas routing and switching platforms have released software in each main release, security platforms have had only the following releases: 17.4, 17.3, 15.1X49, and 12.3X48. Therefore, for example, for a router to upgrade from Release 12.3 to the first release supporting Junos OS with upgraded FreeBSD (Release 15.1) would take multiple upgrades. But for a security device to upgrade from Release 12.3 to the first release supporting Junos OS with upgraded FreeBSD (Release 17.3) would take only one upgrade.
We recommend you upgrade to a 64-bit image of Junos OS with upgraded FreeBSD. In Junos OS releases earlier than 15.1, the partition swap pages are counted as part of the memory file system partition. Using this method leaves 4 GB of memory as the maximum that is theoretically accessible when you are using a 32-bit image. However, when Junos OS with upgraded FreeBSD is run, the system only counts the actual partition size, which leaves around 3.4 GB of available physical address space, or only 3 GB of usable RAM.
To determine which installation package and procedure you require:
1. See the Junos kernel upgrade to FreeBSD 10+ entry in Feature Explorer.
Click the link or go to https://pathfinder.juniper.net/feature-explorer/, type freebsd, and select Junos kernel upgrade to FreeBSD 10+.
You will see a listing of platforms that run Junos OS with upgraded FreeBSD and the software release it was introduced in. Different platforms first support Junos OS with upgraded FreeBSD in different releases. Use this listing to find which release you need to install for your device to upgrade to Junos OS with FreeBSD.

267

2. Consult Table 1 to determine the upgrade path to follow. · Determine which release your device is currently running. Look first at the release sequence and then at the second column and find the release running on your device.
· Determine which release you need to install. The third column will give you the earliest release you need to install for your platform type to be running Junos OS with upgraded FreeBSD.
Table 14: Upgrade Path to Junos OS with the Upgraded FreeBSD

Release Sequen ce

Current Router's Junos OS Release

Earliest Release Supporting Junos OS with Upgraded FreeBSD

Upgrade Path

Example

Routing Earlier

and

than

Switchi Release 15.1

ng

12.3

Upgrade in multiple steps, skipping no more than two releases in one upgrade.

To upgrade from Release 12.1, upgrade first to Release 13.1, then to Release 14.1, then from there to either Release 15.1 or 16.1.

12.3 to 15.1 13.2

Upgrade in two steps.

To upgrade from Release 12.3, first upgrade to Release 13.3, then upgrade to Release 15.1.
To upgrade from Release 13.2, first upgrade to Release 14.2, then upgrade to Release 15.1.

13.3 to 15.1 14.2

Upgrade in a single To upgrade from Release 13.3,

step.

upgrade directly to Release 15.1.

To upgrade from Release 14.2, upgrade directly to either Release 15.1 or 16.1.

268

Table 14: Upgrade Path to Junos OS with the Upgraded FreeBSD (Continued)

Release Sequen ce

Current Router's Junos OS Release

Earliest Release Supporting Junos OS with Upgraded FreeBSD

Upgrade Path

Example

Securit 12.3 to 17.3

y

17.2

Upgrade in a single step.

To upgrade from Release 12.3X48, upgrade directly to Release 17.3.

15.1 to 17.3 17.2

Upgrade in a single step.

To upgrade from Release 15.1X49, upgrade directly to Release 17.3.

15.1 to 17.4 17.3

Upgrade in a single step.

To upgrade from Release 15.1x49-D80, upgrade directly to Release 17.4.

NOTE: You can also downgrade from Junos OS Release with upgraded FreeBSD to Junos OS based on FreeBSD 6.1 as long as the path complies with the Junos OS policy of skipping at most two earlier releases.
3. Download the Junos OS with upgraded FreeBSD package. For a table listing the package prefixes, see Junos OS and Junos OS Evolved Installation Package Names. For more on the names of package name , see Changes in Package Names for Junos OS with Upgraded FreeBSD.
4. Continue installing a software package on a device by using one of the following procedures: · Installing the Software Package on a Router with a Single Routing Engine
· Installing the Software Package on a Device with Redundant Routing Engines

269
Install Junos OS with Upgraded FreeBSD Over Junos OS
Upgrading to Junos OS with upgraded FreeBSD reformats the file system. Only specific files and directories are preserved unless precautions are taken. By default, the upgrade process preserves only the following directories: · /config · /etc/localtime · /var/db · /var/etc/master.passwd · /var/etc/inetd.conf · /var/etc/pam.conf · /var/etc/resolv.conf · /var/etc/syslog.conf · /var/etc/localtime · /var/etc/exports · /var/etc/extensions.allow · /var/preserve · /var/tmp/baseline-config.conf · /var/tmp/preinstall_boot_loader.conf
NOTE: In /var/db/config, up to 10 rollback configurations will be saved, depending on the configuration file size.
NOTE: On EX2300 and EX3400 switches, the following directories are not applicable: · /etc/localtime · /var/etc/localtime · /var/etc/exports

270
· /var/preserve · /var/tmp/preinstall_boot_loader.conf
Before you begin, if you have important files in other directories that are not preserved, copy them from the router or switch to a secure location before upgrading the router or switch.
CAUTION: If you do a media install (either USB or network), the system is wiped and re-partitioned completely. Before you begin, if you have important files, copy them from the device to a secure location before upgrading the device.
To install Junos OS with upgraded FreeBSD over plain Junos OS: 1. Enter the request system software add install-package-name.tgz no-validate command from the
operational mode in the CLI:
NOTE: The no-copy option is enabled by default.
Use the no-validate option with the request system software add command. If you leave out the novalidate option, the command uses the validate option by default, and direct validation of the running configuration does not work for upgrading to Junos OS with upgraded FreeBSD from Junos OS based on older versions of the FreeBSD kernel.
NOTE: You can also use the reboot option along with the request system software add command, but it is not recommended to do this in a single step while upgrading from a FreeBSD 6.1 based Junos OS to Junos OS with upgraded FreeBSD.
NOTE: To validate the current configuration on an upgrade to Junos OS with upgraded FreeBSD from Junos OS, use the request system software validate on (Junos OS with Upgraded FreeBSD) command.
user@host>request system software add /var/tmp/install-package-name.tgz no-validate The new Junos OS image is installed on the device.

271
2. Reboot the device to start the new software using the request system reboot command:
user@host> request system reboot Reboot the system? [yes, no] (no) yes
NOTE: You must reboot the device to load the newly installed version of Junos OS on the device. To terminate the installation, do not reboot the device. Instead, finish the installation and then issue the request system software delete install-package-name.tgz command. This is your last chance to stop the installation (not applicable on EX2300 and EX3400 platforms).
The software is loaded when you reboot the system. Installation can take between 5 and 10 minutes. The device then reboots from the boot device on which the software was just installed. When the reboot is complete, the device displays the login prompt. While the software is being upgraded, the Routing Engine on which you are performing the installation does not route traffic. 3. Log in and issue the show version command to verify the version of the software installed.
NOTE: The output shows the OS kernel, OS runtime, and other packages installed on the device.
Install Junos OS with Upgraded FreeBSD Over Junos OS with Upgraded FreeBSD of a Different Release
CAUTION: If you do a media install (either USB or network), the system is wiped and re-partitioned completely. Before you begin, if you have important files, copy them from the device to a secure location before upgrading the device.
To install Junos OS with upgraded FreeBSD over Junos OS with upgraded FreeBSD of a different release: 1. Enter the request system software add package-name validate reboot command from the
operational mode in the CLI:

272
NOTE: The no-copy option is enabled by default.
Use the validate and reboot options with the request system software add command. The command uses the validate option by default. We encourage users to validate using the validate option when upgrading from Junos OS to Junos OS or from Junos OS with upgraded FreeBSD to Junos OS with upgraded FreeBSD. If you leave out the reboot option, you can take care of that in a separate reboot step. The new Junos OS image is installed on the device. 2. Verify the installation of Junos OS with upgraded FreeBSD.
user@host> show version
NOTE: The output shows the OS kernel, OS runtime, and other packages installed on the device.
RELATED DOCUMENTATION Establishing an SSH Connection for a NETCONF Session
Downgrading from Junos OS with Upgraded FreeBSD
IN THIS SECTION Downgrading from Junos OS with Upgraded FreeBSD to Legacy Junos OS | 273 Downgrading from Junos OS with Upgraded FreeBSD Release 17.4 or Later to Release 15.1 Through 17.3 | 274 Downgrading from Junos OS with Upgraded FreeBSD Release 17.3 or Earlier to Release 15.1 Through 17.2 | 275 Downgrading from Junos OS with Upgraded FreeBSD Release 18.1 or Later to Release 17.4 or Later | 276

273
Starting in Junos OS Release 15.1, certain hardware platforms run a Junos OS based on an upgraded FreeBSD kernel instead of older versions of FreeBSD. To find which platforms support Junos OS with upgraded FreeBSD, see Feature Explorer, enter freebsd, and select Junos kernel upgrade to FreeBSD 10+.
This topic discusses the different procedures for downgrading from a release of Junos OS with upgraded FreeBSD. One procedure describes how to downgrade to legacy Junos OS. The other procedures describe how to downgrade to an earlier release of Junos OS with upgraded FreeBSD.
The main difference between the procedures is whether to use the validate or no-validate option with the request system software add command. If you downgrade between two versions of legacy Junos OS, validate works. Similarly, if you downgrade from Junos OS with upgraded FreeBSD Release 18.1 or later to Release 17.4 or later, validate works. However, there is one set of circumstances in which the no-validate option must be used when downgrading between Junos OS with upgraded FreeBSD releases, and that is when you downgrade from a Junos OS with upgraded FreeBSD Release 17.4 or later to a release earlier than 17.4, that is, Junos OS releases 15.1 through 17.3.
Select and perform the procedure that matches your set of circumstances.
Downgrading from Junos OS with Upgraded FreeBSD to Legacy Junos OS
If you have previously upgraded to Junos OS with upgraded FreeBSD, you can downgrade to an earlier version of Junos OS (that is, legacy Junos OS) as long as the downgrade conforms to the Junos OS policy of skipping at most two earlier releases.
This example uses the package /var/tmp/jinstall-13.3R2.7-domestic-signed.tgz to install legacy Junos OS on the primary Routing Engine (re0).
To downgrade from Junos OS with upgraded FreeBSD to legacy Junos OS:
1. Enter the request system software add package-name no-validate reboot command from the operational mode in the CLI. Use the no-validate and reboot options with the request system software add command. If you leave out the no-validate option, the command uses the validate option by default, and direct validation of running configuration does not work for downgrading to legacy Junos OS from Junos OS with upgraded FreeBSD.
If you leave out the reboot option, you can take care of that in a separate reboot step.
The following example uses the re0 option:
user@host>request system software add /var/tmp/jinstall-13.3R2.7-domestic-signed.tgz re0 novalidate reboot THIS IS A SIGNED PACKAGE Saving the config files ... NOTICE: uncommitted changes have been saved in

274
/var/db/config/juniper.conf.pre-install Rebooting. Please wait ... shutdown: [pid 11001] Shutdown NOW! *** FINAL System shutdown message from root@host *** System going down IMMEDIATELY Shutdown NOW! System shutdown time has arrived\x07\x07 users@host> Connection to device1.example.com closed by remote host. Connection to device1.example.com closed. ... user@router> show version Hostname: host Model: mx240 Junos: 13.3R2.7 JUNOS Base OS boot [13.3R2.7] JUNOS Base OS Software Suite [13.3R2.7] JUNOS Kernel Software Suite [13.3R2.7] JUNOS Crypto Software Suite [13.3R2.7] JUNOS Packet Forwarding Engine Support (M/T/EX Common) [13.3R2.7] JUNOS Packet Forwarding Engine Support (MX Common) [13.3R2.7] JUNOS Online Documentation [13.3R2.7] JUNOS Services AACL Container package [13.3R2.7] ...
2. Verify the downgrade of the software package.
user@host> show version
The output shows the OS kernel, OS runtime, and other packages installed on the device.
Downgrading from Junos OS with Upgraded FreeBSD Release 17.4 or Later to Release 15.1 Through 17.3
This procedure is applicable when downgrading from Junos OS with Upgraded FreeBSD Release 17.4 or later to an earlier release of Junos OS with Upgraded FreeBSD.
NOTE: If you have important files in other directories, copy them from the router or switch to a secure location before upgrading the router or switch.
To downgrade from Junos OS with upgraded FreeBSD Release 17.4 or later to a Release 15.1 through 17.3:
1. Enter the request system software add package-name no-validate reboot command from the operational mode in the CLI: Use the no-validate and reboot options with the request system software add command. If you leave out the no-validate option, the command uses the validate option by default, and direct

275
validation of running configuration does not work for downgrading to an earlier release of Junos OS with upgraded FreeBSD from Junos OS with upgraded FreeBSD Release 17.4 or later. If you leave out the reboot option, you can take care of that in a separate reboot step. The new Junos OS image is installed on the device. 2. Verify the installation of Junos OS with upgraded FreeBSD:
user@host> show version
The output shows the OS kernel, OS runtime, and other packages installed on the device.
Downgrading from Junos OS with Upgraded FreeBSD Release 17.3 or Earlier to Release 15.1 Through 17.2
This procedure is applicable when downgrading from Junos OS with Upgraded FreeBSD Releases 17.3 through 15.1 to an earlier release of Junos OS with Upgraded FreeBSD.
NOTE: If you have important files in other directories, copy them from the router or switch to a secure location before upgrading the router or switch.
To downgrade from Junos OS with upgraded FreeBSD Release 17.3 or earlier to an earlier release of Junos OS with upgraded FreeBSD: 1. Enter the request system software add package-name validate reboot command from the
operational mode in the CLI: Use the validate and reboot options with the request system software add command. The command uses the validate option by default. If you leave out the reboot option, you can take care of that in a separate reboot step. The new Junos OS image is installed on the device. 2. Verify the installation of Junos OS with upgraded FreeBSD:
user@host> show version
The output shows the OS kernel, OS runtime, and other packages installed on the device.

276
Downgrading from Junos OS with Upgraded FreeBSD Release 18.1 or Later to Release 17.4 or Later
This procedure is applicable when downgrading from Junos OS with Upgraded FreeBSD Releases 18.1 or later to a Junos OS with Upgraded FreeBSD Release 17.4 or later.
NOTE: If you have important files in other directories, copy them from the router or switch to a secure location before upgrading the router or switch.
To downgrade from Junos OS with upgraded FreeBSD Release 18.1 or later to Junos OS with Upgraded FreeBSD Release 17.4 or later: 1. Enter the request system software add package-name validate reboot command from the
operational mode in the CLI: Use the validate and reboot options with the request system software add command. The command uses the validate option by default. If you leave out the reboot option, you can take care of that in a separate reboot step. The new Junos OS image is installed on the device. 2. Verify the installation of Junos OS with upgraded FreeBSD:
user@host> show version
The output shows the OS kernel, OS runtime, and other packages installed on the device.
RELATED DOCUMENTATION request system snapshot (Junos OS with Upgraded FreeBSD) | 668 request system reboot (Junos OS with Upgraded FreeBSD) | 643

277
Installing Software on ACX Series Routers
IN THIS SECTION Installing Junos OS Using a USB Storage Device on ACX Series Routers | 277 Installing Junos OS Upgrades from a Remote Server on ACX Series Routers | 278
ACX Series routers are delivered with preinstalled Junos operating system (Junos OS). Before you start this procedure, decide which software package you need and download it. For information on which packages to use for which upgrades, see "Junos OS and Junos OS Evolved Installation Package Names" on page 69.
Installing Junos OS Using a USB Storage Device on ACX Series Routers
To install the Junos OS image on ACX Series routers using a USB storage device, you must have access to the USB port physically and you must also have console access. Perform the following steps to install the Junos OS image: 1. Insert the USB storage device that has a valid installation image into the USB port. 2. Reboot the router by either pressing the power button on the chassis or switching off and turning on
the power button behind the Routing Engine, or by entering the request system reboot command from the CLI. The system LED starts blinking in green. On the console, a message is displayed stating that your flash memory device (NAND Flash device) will be formatted and you will lose all the data. You are prompted to confirm the formatting of the flash memory device. 3. Press y to confirm and proceed with the formatting process. The flash memory device is formatted and the image is installed on both the partitions. After the installation is completed, a message is displayed on the console prompting you to eject the USB storage device and to press Enter to reboot the device. 4. After you remove the USB port and press Enter, the reboot begins. After the router is rebooted, the new Junos OS version is loaded and functional. The LED glows steadily in green.

278
NOTE: If an installation error occurs, the LEDs turn red. You must have console access to the router to troubleshoot an installation error.
Installing Junos OS Upgrades from a Remote Server on ACX Series Routers
You can use the CLI to install Junos OS packages that are downloaded with FTP or HTTP from the specified location on internal media, such as the NAND Flash device. Before you begin: · Verify the available space on the NAND Flash device. · Download the Junos OS package. To install Junos OS upgrades from a remote server, enter the following command from operational mode:
user@host>request system software add junos-juniper-12.2R1.9-domestic.tgz no-copy no-validate reboot The new Junos OS image is installed on the router and the device is rebooted.
NOTE: On ACX5048 and ACX5096 routers, use the force-host option to force installing the latest version of the Host OS. user@host> request system software jinstall-acx5k-15.1X54-D20.6-domestic-signed.tgz force-host add validate reboot
RELATED DOCUMENTATION Configuring Root Partitions on ACX Series Routers | 377

279
Installing and Recovering Software Using the Open Network Install Environment (ONIE)
IN THIS SECTION Understanding the Open Network Install Environment | 280 Downloading Software Files with a Browser | 281 Connecting to the Console Port | 282 Backing Up the Current Configuration Files | 282 Uninstalling the Existing Version of Junos OS | 282 Installing a Junos OS Software Package That Resides on a Webserver or DHCP Server with DHCP Options Configured | 283 Installing Junos OS Software Using Secure Copy Protocol (SCP) | 284 Installing Junos OS Software Using FTP or TFTP Without a Webserver | 285 Installing Junos OS Software Using DHCP Server with No DHCP Options Configured | 286 Installing Junos OS Software Using Webserver Without DHCP Configured | 287 Installing Junos OS Software Using USB Media | 289 Verifying Software Installation | 289 Troubleshooting Boot Problems | 290 Creating an Emergency Boot Device | 291 Performing a Recovery Installation | 292
ONIE, the open network install environment from Cumulus Networks, is a network OS installer that installs Junos OS and third party applications on a switch. Juniper Network switches come pre-installed with ONIE. When you turn on a switch, the ONIE discovery and execution (ODE) application locates the management Ethernet interface and the Junos OS software package, which can be found either locally on the switch or on the network using HTTP, FTP, or TFTP. After the switch discovers and downloads the Junos OS software package, the switch installs the Junos OS software, reboots, and then boots from Junos OS. Junos OS then becomes the default software image.

280
NOTE: If you want to use the Junos OS CLI to install software, see "Installing Software Packages on QFX Series Devices" on page 151.
Upgrading involves these tasks:
Understanding the Open Network Install Environment
When you log into the switch with ONIE, you see the install boot menu: · Juniper Linux (This is a default menu option.) · Juniper Linux Debug · Juniper Linux Recovery · Go to ONIE Loader
· ONIE: Install OS (This is a default menu option.) · ONIE: Rescue · ONIE: Uninstall OS · ONIE: Update ONIE · ONIE: Embed ONIE You can use the following commands to install and uninstall Junos OS and start and stop the ONIE ODE application: · onie-nos-install Installs Junos OS from any URL, such as http://, ftp://, and file://. · onie-uninstaller Uninstalls Junos OS. · onie-discovery-start The discovery process starts automatically. However, if you stop the discovery process by issuing the onie-discovery-stop command, you can restart the discovery process by issuing the onie-discoverystart command.

281
· onie-discovery-stop Stops the discovery process. To restart the discovery process, issue the onie-discovery-start command.
Downloading Software Files with a Browser
You download the software package from the Juniper Networks Downloads page at https:// support.juniper.net.
NOTE: To access the download site, you must have a service contract with Juniper Networks and an access account. If you need help obtaining an account, complete the registration form at the Juniper Networks website https://www.juniper.net/registration/Register.jsp.
To download a software package: 1. Using a Web browser, navigate to the https://support.juniper.net. 2. Either click View all products> and select the product you are downloading software for, or type the
product name. 3. Find the package you want and click the item in the Downloads column.
A login screen appears. 4. Enter your name and password and press Enter. 5. Read the End User License Agreement, click the I agree radio button, and then click Proceed. 6. Save the Junos OS software image file to your computer.
The Junos OS software image file name is presented in the prefix-release-edition-signed.extension format. For example, the image name for Junos OS Release 15.1X53-D10 on QFX10000 series switch is jinstall-qfx-10-f-15.1X53-D10.7-domestic-signed. See "Junos OS and Junos OS Evolved Installation Package Names" on page 69 for additional information on image file naming. 7. Open or save the installation package either to the local system in the var/tmp directory or to a remote location. If you are copying the installation package to a remote system, make sure that you can access it using HTTP, TFTP, FTP, or SCP.

282
Connecting to the Console Port
We recommend that you connect to the console port while installing the installation package so you can respond to any required user input and detect any errors that might occur.
Backing Up the Current Configuration Files
Before you install the new installation package, we strongly recommend that you back up your current configuration files because the upgrade process removes all of the stored files on the switch. To back up your current configuration files, enter the save command:
user@switch# save filename
Executing this command saves a copy of your configuration files to a remote location such as an external USB device.
Uninstalling the Existing Version of Junos OS
The switch comes preinstalled with a version of Junos OS that is to be used with the Junos OS CLI. However, if you want to use ONIE to install Junos OS, you need to uninstall the existing Junos OS and reinstall the Junos OS image that has a .bin extension--for example, jnpr-qfx-5e-jdm-onieupdater-15.1-20150819_ups.4.bin file. To uninstall your existing Junos OS version: 1. Select Go to ONIE Loader from the GNU GRUB menu. 2. Select ONIE: Uninstall OS from the GNU GRUB menu.
The Junos OS is uninstalled, and the switch reboots. By default, the ONIE discovery and execution (ODE) application attempts to discover and fetch an image from a configured DCHP or webserver and the management IP address of the switch and the IP address of the default gateway. If you want to manually configure static addressing for the management IP address of the switch, issue onie-discovery-stop command at the ONIE prompt, and then manually configure the management IP address and IP address of the default gateway.

283
For example:
ONIE:/ # onie-discovery-stop ONIE:/ # ifconfig eth0 10.204.32.96 netmask 255.255.254.0
ONIE:/ # route add default gw 10.204.47.254
To restart the ONIE discovery and execution (ODE) application, issue the onie-discovery-start command. For example:
ONIE:/ # onie-discovery-start
Installing a Junos OS Software Package That Resides on a Webserver or DHCP Server with DHCP Options Configured
To install a Junos OS software package residing on a webserver or DHCP server: 1. Copy the software image with the filename onie-installer to the var/www/html directory of the
webserver or DHCP server. 2. Configure the DHCP option 114 in the DHCP server to redirect to the webserver to fetch the Junos
OS software image. 3. Uninstall the preinstalled Junos OS version.
· Select Go to ONIE Loader from the GNU GRUB menu. · Select ONIE: Uninstall OS from the GNU GRUB menu. The Junos OS is uninstalled, and the switch reboots. 4. Configure DHCP option 114 and other DHCP options as necessary. Here is a sample Windows Open DHCP server configuration with DHCP option 114 configured.
#Following are range-specific DHCP options. #You can copy more option names from [GLOBAL_OPTIONS] IP=10.204.42.250 SubnetMask=255.255.240.0

284

Router=10.204.47.254 114="http://10.207.66.147/onie-installer"
Here is a sample boot initialization log, showing the options you just configured:

Info: Trying DHCPv4 on interface: eth0 ONIE: Using DHCPv4 addr: eth0: 10.204.42.250 / 255.255.240.0 ONIE: Starting ONIE Service Discovery Info: Fetching http://10.207.66.147/onie-installer ... ONIE: Executing installer: http://10.207.66.147/onie-installer automatically redirects to web sever to fetch Junos OS image. Verifying image checksum ... OK. Preparing image archive ... OK. Installing Juniper NOS...

<<<<<<----

The log shows that the installation process has fetched the Junos OS software image from the DHCP server and is installing the Junos OS software.
The switch reboots and the GNU GRUB menu is displayed.

Installing Junos OS Software Using Secure Copy Protocol (SCP)
To install Junos OS software using SCP: 1. Uninstall the preinstalled Junos OS version.
· Select Go to ONIE Loader from the GNU GRUB menu. · Select ONIE: Uninstall OS from the GNU GRUB menu. The Junos OS is uninstalled, and the switch reboots. By default, the ONIE discovery and execution (ODE) application attempts to discover and fetch an image from a configured webserver. If you do not have DHCP configured, you will need to stop the ONIE discovery and execution (ODE) application and manually configure static addressing for the management IP address of the switch, For example:
ONIE:/ # onie-discovery-stop ONIE:/ # ifconfig eth0 10.204.32.96 netmask 255.255.254.0

285
ONIE:/ # route add default gw 10.204.47.254 2. Use SCP to copy the Junos OS image from a server or other location to the /var/tmp directory on
the switch. For example:
user@server scp jnpr-qfx-5e-jdm-onie-updater-15.1-20150819_ups.4.bin root@10.204.32.196:/var/tmp/ 3. Issue the onie-nos-install command in the /var/tmp directory to install Junos OS software.
ONIE:/var/tmp # onie-nos-install file:///var/tmp/jnpr-qfx-5e-jdm-onieupdater-15.1-20150819_ups.4.bin
The switch reboots and displays the GNU GRUB menu.
Installing Junos OS Software Using FTP or TFTP Without a Webserver
To install Junos OS software using FTP or TFTP: 1. Uninstall the preinstalled Junos OS version.
· Select Go to ONIE Loader from the GNU GRUB menu. · Select ONIE: Uninstall OS from the GNU GRUB menu. The Junos OS is uninstalled, and the switch reboots. By default, the ONIE discovery and execution (ODE) application attempts to discover and fetch an image from a configured webserver. If you do not have DHCP configured, you will need to stop the ONIE discovery and execution (ODE) application and manually configure static addressing for the management IP address of the switch, For example:
ONIE:/ # onie-discovery-stop ONIE:/ # ifconfig eth0 10.204.32.96 netmask 255.255.254.0
ONIE:/ # route add default gw 10.204.47.254

286
2. Copy the Junos OS image to an FTP or TFTP directory. 3. Issue the onie-nos-install command at the ONIE prompt to install the Junos OS software.
If you are using FTP:
ONIE:/ # onie-nos-install ftp://<username>:<password>@10.209.152.22/jnpr-qfx-5e-jdm-onieupdater-15.1-20150819_ups.4.bin
If you are using TFTP:
NOTE: The software image should be located in the /tftp/boot directory.
ONIE:/ # onie-nos-install tftp://10.207.66.147/jnpr-qfx-5e-jdm-onieupdater-15.1-20150819_ups.4.bin
The switch reboots and displays the GNU GRUB menu.
Installing Junos OS Software Using DHCP Server with No DHCP Options Configured
Use this installation method if you cannot modify or set the DHCP options on your DHCP server. To install the Junos OS software using a DHCP server with no DHCP options configured: 1. Copy the software image with the filename jnpr-qfx-5e-jdm-onie-updater-15.1-20150819_ups.4.bin
to the var/www/html directory of the webserver or DHCP server. 2. Uninstall the preinstalled Junos OS version.
· Select Go to ONIE Loader from the GNU GRUB menu. · Select ONIE: Uninstall OS from the GNU GRUB menu. The Junos OS is uninstalled, and the switch reboots. 3. Issue the onie-nos-install command at the ONIE prompt to install the Junos OS software. For example:
ONIE:/ # onie-nos-install http://10.207.66.147/jnpr-qfx-5e-jdm-onieupdater-15.1-20150819_ups.4.bin

287

Here is sample log with the options you just configured:

ONIE:/ # ifconfig

eth0

Link encap:Ethernet HWaddr 94:DE:80:AA:F2:E1

inet addr:10.204.42.250 Bcast:10.204.47.255 Mask:255.255.240.0

<<<---- --> Received IP address from DHCP server, but auto redirected to web

server. Installation will not happen because DHCP option (114) is not

configured.

inet6 addr: fe80::96de:80ff:feaa:f2e1/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:444 errors:0 dropped:0 overruns:0 frame:0 TX packets:17 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:48170 (47.0 KiB) TX bytes:2678 (2.6 KiB) Memory:80180000-801a0000
This log shows that the installation process has fetched the Junos OS software image from the webserver and is installing the Junos OS software.

Stopping: discover... done.

Info: Fetching http://10.207.66.147/jinstall-qfx-10-f-15.1X53-D10.7-domestic-

signed.tgz ...

Connecting to 10.207.66.147 (10.207.66.147:80)

installer

100% |*******************************| 464M 0:00:00

ETA

ONIE: Executing installer: http://10.207.66.147/jnpr-qfx-5e-jdm-onie-

updater-15.1-20150819_ups.4.bin

Verifying image checksum ... OK.

Preparing image archive ... OK.

Installing Juniper NOS...

The switch reboots and the GNU GRUB menu is displayed.

Installing Junos OS Software Using Webserver Without DHCP Configured
Use this installation method if you do not have a DHCP server.

288

To install the Junos OS software using a webserver without DHCP configured:
1. Because the switch comes preinstalled with the Junos OS to be used with the Junos OS CLI, you need to uninstall this version of software before you can install the Junos OS image to be used with ONIE. · Select Go to ONIE Loader from the GNU GRUB menu.
· Select ONIE: Uninstall OS from the GNU GRUB menu.
The Junos OS is uninstalled, and the switch reboots. 2. Select ONIE: Uninstall OS from the GNU GRUB menu.
The Junos OS is uninstalled, and the switch reboots.
By default, the ONIE discovery and execution (ODE) application attempts to discover and fetch an image from a configured webserver. Because you do not have DHCP configured, you will need to stop the ONIE discovery and execution (ODE) application and manually configure static addressing for the management IP address of the switch.
For example:

ONIE:/ # onie-discovery-stop ONIE:/ # ifconfig eth0 10.204.32.96 netmask 255.255.254.0
ONIE:/ # route add default gw 10.204.47.254
3. Copy the software image to the var/www/html directory of the webserver. 4. Issue the onie-nos-install command at the ONIE prompt to install the Junos OS software.
For example:

ONIE:/ # onie-nos-install http://10.204.35.100/jnpr-qfx-5e-jdm-onieupdater-15.1-20150819_ups.4.bin
Here is sample log:

Stopping: discover... done.

Info: Fetching http://10.204.35.100/jnpr-qfx-5e-jdm-onie-

updater-15.1-20150819_ups.4.bin ...

Connecting to 10.204.35.100 (10.204.35.100:80)

installer

100% |*******************************| 464M 0:00:00

ETA

ONIE: Executing installer: http://10.204.35.100/jnpr-qfx-5e-jdm-onie-

289
updater-15.1-20150819_ups.4.bin Verifying image checksum ... OK. Preparing image archive ... OK. Installing Juniper NOS... The log shows that the installation process has fetched the Junos OS software image from the webserver and is installing the Junos OS software. The switch reboots and the GNU GRUB menu is displayed.
Installing Junos OS Software Using USB Media
ONIE installation from a Junos OS image stored on USB media is not currently supported. Use another procedure from this document to install ONIE.
Verifying Software Installation
IN THIS SECTION Purpose | 289 Action | 289
Purpose
Verify that the software was installed successfully on the switch.
Action
To verify that the software was properly installed, issue the show version command.
user@switch > show version

290
Troubleshooting Boot Problems
IN THIS SECTION Problem | 290 Solution | 290

Problem
Description
Junos OS does not boot.
Solution
If Junos OS does not boot, and the console displays the Yocto GNU Linux shell instead, it could mean that you have booted in the Juniper Linux Debug mode. If you see an error message that says, "[Error] Does not seem to be an QFX10002." could mean that the EEPROM does not contain vendor-specific information. To verify the vendor-specific information, perform an ONIE: Rescue installation, and then verify the contents of the /var/run/*.dat file. 1. Select ONIE: Rescue from the GNU GRUB menu. 2. Issue the onie-syseeprom at the ONIE prompt.
For example:

ONIE:/ # onie-syseeprom

TlvInfo Header:

Id String: TlvInfo

Version:

1

Total Length: 315

TLV Name

Code Len Value

-------------------- ---- --- -----

Base MAC Address

0x24 6 54:2A:A2:FB:DC:00

MAC Addresses

0x2A 2 256

Product Name

0x21 23 QFX10000-ÿÿÿÿÿÿÿ

Serial Number

0x23 12 116G1EC00032

291

Part Number

0x22 16 1AES48S6Q.A2Gÿÿÿ

Device Version

0x26 1 1

Manufacture Date

0x25 19 01/13/2015 21:40:30

Vendor Name

0x2D 20 JUNIPER NETWORKS INC

Manufacturer

0x2B 14 JUNIPER NETWORKS INC

Vendor Extension

0xFD 48 0x00 0x00 0x7C 0x82 0x01 0x00 0x41 0x32 0xFF

0xFF 0xFF 0xFF 0xFF 0xFF 0x0F

Vendor Extension

0xFD 62 0x00 0x00 0x0A 0x4C 0x51 0x06 0x52 0x45 0x56

0x20 0x30 0x31 0x52 0x0C 0x3F

Platform Name

0x28 37 x86_64-alpha_networks_snx60a0_486f-r0

Loader Version

0x29 23 master-201412161452.0.1

CRC-32

0xFE 4 0xB88C8885

Checksum is valid.

From the output, you can see that the vendor-specific information confirms that it is for Juniper Networks.

Creating an Emergency Boot Device
Before you begin, you need to have the jnpr-qfx-5e-jdm-onie-updater-15.1-20150819_ups.4.bin version of ONIE software. If the Open Network Install Environment (ONIE) software is damaged or corrupted in some way, or the switch went into rescue mode, you can use an emergency boot device to repartition the primary disk and load a fresh installation of ONIE. Use the following procedure to create an emergency boot device.
NOTE: In the following procedure, we assume that you are creating the emergency boot device on a switch. You can create the emergency boot device on any PC or laptop that supports Linux.
To create an emergency boot device: 1. Insert the USB device into the front USB port of the switch.
Make sure the USB device is at least 1GB. 2. Issue the following command from the directory on the switch in which the ISO file is located:
ONIE:/ # jnpr-qfx-5e-jdm-onie-updater-15.1-20150819_ups.4.bin of=<usb-detected-drive> bs=1M
You can also issue the dd command using the full path to where the ISO file is located.

292
For example, if the ISO file is located in the /var/tmp/ directory:
ONIE:/ # dd if=/var/tmp/jnpr-qfx-5e-jdm-onie-updater-15.1-20150819_ups.4.bin of=<usb-detecteddrive> bs=1M The switch writes the installation media image to the USB device: 3. Remove the USB device from the USB port of the switch.
Performing a Recovery Installation
In the event that the Open Network Install Environment (ONIE) is corrupted, the switch goes into rescue mode, or you need to reinstall ONIE software for any reason, you need to perform a recovery installation.
NOTE: All Junos OS partitions are destroyed during a recovery installation.
NOTE: Before you can perform a recovery installation, make sure you have an emergency boot device loaded with ONIE software.
1. Insert the emergency boot device into the device. 2. Power cycle the device. 3. Press the ESC button to go into the Boot Manager menu. 4. Select Boot Manager, and then press Enter. 5. Select Unigen PQS1000 under Legacy USB, and then press Enter. 6. Select ONIE: Embed ONIE from the ONIE Installer menu, and then press Enter.
The recovery installation proceeds using the emergency boot device. 7. Remove the emergency boot device. 8. Verify that the ONIE software was installed by looking at the installation log file.

293

For example:

Info: Found static url: file:///lib/onie/onie-updater

ONIE: Executing installer: file:///lib/onie/onie-updater

Verifying image checksum ... OK.

Preparing image archive ... OK.

ONIE: Version

: master-201412161452.0.1

Installation log files are displayed automatically during the installation process, but if you want to verify installation log files at a different time, you can find them in the in the /var/log/ directory. To view an installation log file, issue the tail -f /var/log/onie.log command.
9. Issue the parted /dev/sda print command to verify that the ONIE partitions have been created.
For example:

ONIE:/ # parted /dev/sda print Model: ATA TS8GHSD630 (scsi) Disk /dev/sda: 8012MB Sector size (logical/physical): 512B/512B Partition Table: gpt Disk Flags:

Number 1 2

Start 1049kB 3146kB

End 3146kB 137MB

Size 2097kB 134MB

File system ext4

Name GRUB-BOOT ONIE-BOOT

Flags hidden, bios_grub hidden

RELATED DOCUMENTATION
Installing Software Packages on QFX Series Devices | 151 Upgrading Software by Using Automatic Software Download for Switches | 165 Configuring a DHCP Server on Switches

294
Overview of Upgrading to 64-bit Junos OS
IN THIS SECTION Upgrading Redundant Routing Engines from 32-bit to 64-bit Junos OS | 295 Upgrading a Single Routing Engine from 32-bit to 64-bit Junos OS Using One Slot | 297 Upgrading a Single Routing Engine from 32-bit to 64-bit Junos OS Using Two Slots | 297
Just like any other operating system, the 64-bit version of Junos OS can address more memory than the 32-bit version of Junos OS. In order to support larger Routing Engine memory sizes, an upgrade from the 32-bit to the 64-bit Junos OS running on the Routing Engine hardware is necessary. The in-service software upgrade (ISSU) procedure is not supported while upgrading from the 32-bit version of Junos OS to the 64-bit version of Junos OS. The upgrade process involves some downtime, so traffic will be affected. If you are starting with 32-bit Junos OS running on Routing Engines that are not 64-bit capable, there are two parts of the upgrade: upgrading the hardware and upgrading the software. This topic provides an overview of the upgrade tasks and the order in which they must be performed. For more detailed information about replacing the Routing Engines, see the hardware guide for your router. The following upgrade scenarios are covered in this overview:

295
Upgrading Redundant Routing Engines from 32-bit to 64-bit Junos OS
For a diagram ot this procedure, see Figure 2 on page 295. For the purposes of this procedure, slot 0 has the primary Routing Engine initially. Figure 2: Upgrading to 64-bit Junos OS with Redundant Routing Engines
To upgrade redundant Routing Engines from 32-bit Junos OS to 64-bit Junos OS: 1. If the backup Routing Engine in slot 1 is not 64-bit capable, replace it with a 64-bit capable Routing
Engine.

296
NOTE: The 64-bit version of Junos OS is not supported on every Routing Engine. To determine whether your router and Routing Engine support a 64-bit version of Junos OS, see Supported Routing Engines by Router.
For instructions on replacing a Routing Engine, see the hardware guide for your router. 2. Log in to the primary Routing Engine in slot 0, and prepare the router for software package upgrade.
See "Installing the Software Package on a Device with Redundant Routing Engines" on page 123. 3. Install 64-bit Junos OS on the backup Routing Engine in slot 1.
CAUTION: Mixing 32-bit Junos OS and 64-bit Junos OS can only be done temporarily. It is not supported for normal operations.
See "Installing the Software Package on a Device with Redundant Routing Engines" on page 123. 4. Switch primary role from slot 0 to slot 1.
user@host> request chassis routing-engine master switch
Now the Routing Engine in slot 1 is the primary Routing Engine. 5. If the Routing Engine in slot 0 is not 64-bit capable, replace it with a 64-bit capable Routing Engine.
NOTE: The 64-bit version of Junos OS is not supported on every Routing Engine. To determine whether your router and Routing Engine support a 64-bit version of Junos OS, see Supported Routing Engines by Router.
For instructions on replacing a Routing Engine, see the hardware guide for your router. 6. Install 64-bit Junos OS on the Routing Engine in slot 0.
See "Installing the Software Package on a Device with Redundant Routing Engines" on page 123. 7. (Optional) Switch primary role from slot 1 to slot 0.
user@host> request chassis routing-engine master switch 8. Finalize the installation.
See "Installing the Software Package on a Device with Redundant Routing Engines" on page 123. This includes synchronization of the configuration on the Routing Engines.

297
Upgrading a Single Routing Engine from 32-bit to 64-bit Junos OS Using One Slot
To upgrade a single Routing Engine, from 32-bit to 64-bit Junos using one slot: 1. If the Routing Engine is not 64-bit capable, replace it with a 64-bit capable Routing Engine.
NOTE: The 64-bit version of Junos OS is not supported on every Routing Engine. To determine whether your router and Routing Engine support a 64-bit version of Junos OS, see Supported Routing Engines by Router.
For instructions on replacing a Routing Engine, see the hardware guide for your router. 2. Install 64-bit Junos OS on the Routing Engine using the no-validate option.
user@host> request system software add /var/tmp/software-package no-validate For more details on installing software on a single router, see "Installing the Software Package on a Router with a Single Routing Engine" on page 121. 3. Reboot.
user@host> request system reboot
Upgrading a Single Routing Engine from 32-bit to 64-bit Junos OS Using Two Slots
This procedure provides a way to upgrade to a 64-bit Junos OS using two Routing Engine slots. Using two slots reduces the amount of network downtime. If you have only one slot, use procedure "Upgrading a Single Routing Engine from 32-bit to 64-bit Junos OS Using One Slot" on page 297.

298 For a diagram of this procedure, see Figure 3 on page 298. In this procedure, slot 1 is initially empty. Figure 3: Upgrading a Single Routing Engine to 64-bit Junos OS Using Two Slots
To upgrade a single Routing Engine to 64-bit Junos OS using two Routing Engine slots: 1. Install a 64-bit capable Routing Engine in slot 1.
NOTE: The 64-bit version of Junos OS is not supported on every Routing Engine. To determine whether your router and Routing Engine support a 64-bit version of Junos OS, see Supported Routing Engines by Router. For instructions on installing a Routing Engine, see the hardware guide for your router. 2. Install 64-bit Junos OS on the now backup Routing Engine in slot 1. See "Installing the Software Package on a Device with Redundant Routing Engines" on page 123.

299
CAUTION: Mixing 32-bit Junos OS and 64-bit Junos OS is not supported for normal operations. You need to remove the Routing Engine from slot 0 to avoid mixing 32-bit Junos OS and 64-bit Junos OS. 3. Switch the primary Routing Engine from slot 0 to slot 1.
user@host> request chassis routing-engine master switch 4. When the 64-bit Junos OS is configured properly, remove the Routing Engine from slot 0 .
For instructions on removing a Routing Engine, see the hardware guide for your router.
RELATED DOCUMENTATION Installing the Software Package on a Device with Redundant Routing Engines | 123 Installing the Software Package on a Router with a Single Routing Engine | 121
Veriexec Overview
IN THIS SECTION How Veriexec Works | 300 The Importance of Veriexec | 301 How to Verify If Veriexec Is Enforced on a Device Running Junos OS | 301 Veriexec-Capable Loader for SRX Series devices | 303
Verified Exec (also known as veriexec) is a file-signing and verification scheme that protects the Junos operating system (OS) against unauthorized software and activity that might compromise the integrity of your device. Originally developed for the NetBSD OS, veriexec was adapted for Junos OS and enabled by default from Junos OS Release 7.5 onward.

300
Authorized files, that is certain files that ship with Junos, have an associated fingerprint that veriexec checks to determine whether the file can be used (executed, or even opened). Any file which lacks a valid fingerprint cannot be executed or read by applications that require verified input. Note that /bin/sh does not require verified input. It can be used to run arbitrary scripts because from a risk perspective, they are the same as interactive commands, which is already controlled through user authentication and permissions. However, if a verified shell script contains instructions to run an arbitrary script, that is, a file that does not have a signature in the manifest, execution of that file will be prevented.
How Veriexec Works
Veriexec provides the kernel with a digitally signed manifest consisting of a set of fingerprints for all the executables and other files that should remain immutable. The veriexec loader feeds the contents of the manifest to the kernel only if the digital signature of the manifest is successfully verified. The kernel can then verify if a file matches its fingerprint. If veriexec is being enforced, only executables with a verified fingerprint will run. The protected files cannot be written to, modified, or changed. Each install image contains a manifest. The manifest is read-only. It contains entries such as the following:
etc/rc sha1=478eeda6750c455fbfc18eeb06093e32a341911b uid=0 gid=0 mode=644 etc/rc.verify sha1=15566bb2731abee890fabd0ae8799e02071e006c uid=0 gid=0 mode=644
usr/libexec/veriexec-ext.so.1 sha1=8929292d008d12cd5beb2b9d9537458d4974dd22 uid=0 gid=0 mode=550 no_fips
sbin/verify-sig sha1=cd3ffd45f30f1f9441e1d4a366955d8e2c284834 uid=0 gid=0 mode=555 no_ptrace sbin/veriexec sha1=7b40c1eae9658f4a450eb1aa3df74506be701baf uid=0 gid=0 mode=555 no_ptrace
jail/usr/bin/php sha1=c444144fef5d65f7bbc376dc3ebb24373f1433a2 uid=0 gid=0 mode=555 indirect no_fips
usr/sbin/chassisd sha1=61b82b36da9c6fb7eeb413d809ae2764a8a3cebc uid=0 gid=0 mode=555 trusted

301
If a file has been modified and the resulting fingerprint differs from the one in the manifest, you will see a log message, such as the following example:
/kernel:veriexec:fingerprintfordev100728577,file70750 64ea873ed0ca43b113f87fa25fb30f9f60030cec!= 0d9457c041bb3646eb4b9708ba605facb84a2cd0
The log message is in the following format:
/kernel:veriexec:fingerprintfordev<deviceid>,file<fileid><calculatedfingerprint>! = <fingerprintinthemanifest>
The fingerprint mismatch indicates that the file has been modified. Don't try to run the file. It could contain corrupted code. Contact JTAC.
The Importance of Veriexec
Veriexec is an effective and important tool for protecting against those seeking to breach the system security of Juniper Networks routers, switches, and firewalls. It thwarts threat actors who might want to establish a foothold on the system, gain persistent unauthorized access, or otherwise transition the system into a failure state. If such actors can run arbitrary unsigned binaries, they can make unauthorized modifications and run malware or other code that violates security policy. Customers can add signed and authorized code with veriexec enforced to Junos OS by using the JET SDK. For more on the SDK solution, see On-Device Applications in the Juniper Extension Toolkit Developer Guide.
How to Verify If Veriexec Is Enforced on a Device Running Junos OS
The following subsections give procedures on how to check if veriexec is enforced or not. Some Junos OS platforms offer an optional version of Junos OS with veriexec enforcement disabled (referred to as Junos Enhanced Automation or Junos Flex). For more information about Junos Enhanced Automation, see Overview of Junos Automation Enhancements on Devices Running Junos OS with Enhanced Automation.

302
Use the sysctl security.mac.veriexec.state Command for Junos OS Release 15.1 and Later Administrators can check whether veriexec is enforced by running the following commands from the Junos CLI shell: 1. Start the shell.
username@hostname> start shell %
2. Use the sysctl security.mac.veriexec.state command.
% sysctl security.mac.veriexec.state security.mac.veriexec.state: loaded active enforce %
If veriexec is enforced, the output is security.mac.veriexec.state: loaded active enforce. If veriexec is not enforced, the output is security.mac.veriexec.state: loaded active.
NOTE: The security.mac.veriexec.state command is only valid in Junos OS Release 15.1 and later.
Another Way to Check If Veriexec Is Working You can confirm whether veriexec is working by copying an authorized file (here, /usr/bin/id), to a new location as shown below. Veriexec prevents the operation because, although there is a valid fingerprint for /usr/bin/id, there is no fingerprint for /tmp/id even though the file is identical. What is happening is that veriexec evaluates the underlying Linux properties of the file, which are not identical after being copied, rather than the file itself. 1. Start the shell.
username@hostname> start shell #

303
2. Change directories and then copy the example file, /usr/bin/id to a new location.
# /usr/bin/id uid=928(username) gid=20 groups=20,0(wheel),10(field) # cp /usr/bin/id /tmp
Results If veriexec is being enforced, an Authentication error appears. If it is not, the file will be run as normal. Output when veriexec is enforced (the file is blocked):
# /tmp/id /bin/sh: /tmp/id: Authentication error # Output when veriexec is not enforced (the file is copied):
# /tmp/id #
Veriexec-Capable Loader for SRX Series devices
The veriexec-capable loader installs a Junos OS image using the install command from a TFTP server or a USB storage device. · Install the Junos OS image from a tftp server using the install tftp://[host]/ install command.
loader> install tftp://[host]/package · Install the Junos OS image from a USB storage device using the install file:/// install command.
loader> install file:///package

304
The veriexec-capable loader validates the Junos OS image. The veriexec-capable loader boots up only a new Junos OS image with fingerprints and does not boot up the existing Junos OS image without fingerprints or kernel. You can use the nextboot function to check the current bootup device.
username@hostname# nextboot Platform: srx-sword
eUSB usb current bootdev is: eUSB
Bootupgrade is a tool available in the Junos OS package to support BIOS firmware upgrading. You can use the bootupgrade command to upgrade, check uboot, manually load, and to install the larger size veriexec-capable loader. The bootupgrade -c loader command prints the version string for current loader. Before you install the veriexec-capable loader to Junos OS image, a Junos OS fingerprints identification is carried out in both dual-root partitions. Only when both dual-root partitions have Junos OS with fingerprints, is the veriexec capable loader installation allowed. Install the veriexec-capable loader from the Junos OS CLI shell: 1. Start the shell.
username@hostname> start shell %
2. Use the bootupgrade -l /boot/veloader command to install the veriexec-capable loader.
% bootupgrade -l /boot/veloader Checking Loader CRC... veloader size 1251641 OK
3. You can see different scenarios here: · For Junos OS Release 20.3R1 and later, use request system software add /var/tmp/xxx.tgz nocopy no-validate command to install Junos OS with fingerprints normally.
username@hostname> request system software add /var/tmp/junossrxsme-20.4I-20200810_dev_common.0.0833.tgz no-copy no-validate Formatting alternate root (/dev/ad0s2a)... /dev/ad0s2a: 600.0MB (1228732 sectors) block size 16384, fragment size 2048
using 4 cylinder groups of 150.00MB, 9600 blks, 19200 inodes.

305

super-block backups (for fsck -b #) at: 32, 307232, 614432, 921632 Installing package '/altroot/cf/packages/install-tmp/ junos-20.4I-20200810_dev_common.0.0833' ... Verified junos-boot-srxsme.tgz signed by PackageDevelopmentECP256_2020 method ECDSA256+SHA256 Verified junos-srxsme-domestic signed by PackageDevelopmentECP256_2020 method ECDSA256+SHA256 Verified manifest signed by PackageDevelopmentECP256_2020 method ECDSA256+SHA256

WARNING: WARNING:

The software that is being installed has limited support. Run 'file show /etc/notices/unsupported.txt' for details.

JUNOS 20.4I-20200810_dev_common.0.0833 will become active at next reboot

WARNING: A reboot is required to load this software correctly

WARNING:

Use the 'request system reboot' command

WARNING:

when software installation is complete

Saving state for rollback ...

· For Junos OS Releases prior to 20.3R1, if the veriexec-capable loader is in use and the target Junos OS image for previous releases are not supported by the veriexec-capable loader, then use the request system software add /var/tmp/xxx.tgz no-copy no-validate command to automatically downgrade to the old loader from the veriexec-capable loader.

username@hostname> request system software add /var/tmp/junos-srxsme-19.4R1.3.tgz no-copy no-validate WARNING: Package junos-19.4R1.3 version 19.4R1.3 is not compatible with current loader WARNING: Automatic recovering loader, please wait ... Upgrading Loader... ##################################### Verifying the loader image... OK WARNING: The new boot firmware will take effect when the system is rebooted. WARNING: Loader recover finish. Formatting alternate root (/dev/ad0s1a)... /dev/ad0s1a: 598.5MB (1225692 sectors) block size 16384, fragment size 2048
using 4 cylinder groups of 149.62MB, 9576 blks, 19200 inodes. super-block backups (for fsck -b #) at: 32, 306464, 612896, 919328

306
Installing package '/altroot/cf/packages/install-tmp/junos-19.4R1.3' ... Verified junos-boot-srxsme-19.4R1.3.tgz signed by PackageProductionEc_2019 method ECDSA256+SHA256 Verified junos-srxsme-19.4R1.3-domestic signed by PackageProductionEc_2019 method ECDSA256+SHA256 Verified junos-boot-srxsme-19.4R1.3.tgz signed by PackageProductionEc_2019 method ECDSA256+SHA256 V erified junos-srxsme-19.4R1.3-domestic signed by PackageProductionEc_2019 method ECDSA256+SHA256 JUNOS 19.4R1.3 will become active at next reboot WARNING: A reboot is required to load this software correctly WARNING: Use the 'request system reboot' command WARNING: when software installation is complete Saving state for rollback ...
· Use the request system software add /var/tmp/xxx command to check whether the Junos OS package is compatible for the installation.
username@hostname> request system software add /var/tmp/junos-srxsme-19.4R2.3.tgz WARNING: Package junos-19.4R2.3 version 19.4R2.3 is not compatible with this system. WARNING: Please install a package with veloadr support, 20.3 or higher.
The installation is terminated because the veriexec-capable loader is not supported for Junos OS Releases prior to 20.3R1.

4 CHAPTER
VM Host Support on Routing Engines
VM Host Overview | 308 Boot Process for Routers with VM Host Support | 317 Installing, Upgrading, Backing Up, and Recovery of VM Host | 319 Copying VM Host Installation Package to the PXE Boot Server | 325 Creating an Emergency Boot Device for Routing Engines with VM Host Support |
328 Upgrading the SSD Firmware on Routing Engines with VM Host Support | 330 Upgrading the i40e NVM Firmware on Routing Engines with VM Host Support |
333 Disabling Autorecovery on Routing Engines with VM Host Support | 343 VM Host Operations and Management | 343

308
VM Host Overview
IN THIS SECTION What Are VM Hosts? | 308 Routing Engines with VM Host Support | 309 Salient Features of the Routing Engines with VM Host Support | 310
What Are VM Hosts?
Starting in Junos OS Release 16.1, virtualized Routing Engines are supported that not only provide increased control plane scalability and performance but also provide virtualization capabilities to the Junos OS infrastructure. These virtualized Routing Engines, or VM hosts, are the Routing Engines REMX-X6, RE-MX-X8, RE-PTX-X8, RE-QFX10002-60C.
NOTE: VM hosts only run Junos OS with Upgraded FreeBSD.
The rest of this section describes the architecture of VM hosts. For more information on VM hosts, see the chapters on System Back Up and Recovery, Installing Software, Installing Firmware, and so on in this guide. Figure 4 on page 309 illustrates the architecture of RE-MX-X6, RE-MX-X8, RE-PTX-X8, REQFX10002-60C Routing Engines. It comprises the following components: · The hardware layer · The operating system and hypervisor layer. · The host utilities and Junos VM guest layer. The server at the hardware layer contains the physical network interface cards (NICs), CPUs, memory, and Ethernet management port. The NICs support hardware virtualization based on single root I/O virtualization (SR-IOV). With SR-IOV, the physical NICs (known as a physical functions) are managed by the host, while the virtual functions are managed by the guest OS. Over the hardware layer, a Linuxbased OS provides the host environment along with the kernel-based virtual machine (KVM) and Quick Emulator (QEMU). This host OS manages the boot complex, CPU memory storage, and various other hardware components such as the physical functions. Junos OS runs as guest OS, manages the virtual

309 functions, and serves as the administrative framework. Additionally, it also provides the interface for managing the host and the hypervisor. The additional applications and utilities running on the host OS assist in providing the following functionality: · Facilitating communication between host OS and guest OS. · Triggering appropriate execution of the host OS based on the command and configuration on the
guest Junos OS. · Extending the VM management functionality to provide features such as autorecovery. Figure 4: Architecture of RE-MX-X6, RE-MX-X8, RE-PTX-X8, RE-QFX10002-60C, and REPTX10002-60C Routing Engines
Routing Engines with VM Host Support
The Routing Engines RE-ACX-5448, RE-MX-X6, RE-MX-X8, RE-PTX-X8, RE-QFX10002-60C, and REPTX10002-60C not only provide increased control plane scalability and performance but also provide virtualization capabilities to the Junos OS infrastructure to support greater computing demands.

310
Virtualization enables multiple instances of operating systems, called guests, to run concurrently on the host and share virtualized hardware resources. A guest is a virtual machine (VM) that runs on a hypervisor-based host and shares its resources. A host is a virtualized software whose hypervisor allows multiple guest VMs to run on it concurrently and share its resources. A VM can be an instance of Junos OS or any compatible third-party VM. Each VM runs its own operating system image and applications that can be different from that of another VM running on the same host. On the RE-ACX-5448, RE-MX-X6, RE-MX-X8, RE-PTX-X8, RCBPTX, RE-QFX10002-60C, and REPTX10002-60C Routing Engines, one instance of Junos OS runs as a VM over a Linux-based host (VM host) and serves as the VM operating in the administrative context. Junos OS manages all configurations, chassis control, communication with the host OS, and user interface command execution, thus providing near-native Junos OS experience to the end user. See Hardware Specifications of the RE-MX-X6, RE-MX-X8, RE-PTX-X8, RCBPTX, RE-QFX10002-60C, and RE-PTX10002-60C Routing Engines for more information on hardware specifications of the Routing Engines with VMHost support.
NOTE: Platform support depends on the Junos OS release in your installation.
SEE ALSO Supported Routing Engines by Router
Salient Features of the Routing Engines with VM Host Support
IN THIS SECTION Platform Virtualization | 311 Hardware Assisted Paravirtualized Guest Junos OS | 311 Guest Junos OS to Serve as the Administrative Framework | 311 Storage Partitioning and Redundancy | 311 NTP and Time Zone | 315 Autorecovery | 315 Handling Reboot and Power Off | 315

311
While continuing to provide the same end-user experience, the new architecture provides a better performing Routing Engine.
The following are the salient features of the Routing Engines:
Platform Virtualization
Platform virtualization by the introduction of a middle layer that comprises the host OS and the KVM (or the hypervisor).
· Enables support for multiple instances of Junos OS to be run concurrently.
· Enables support for third-party software to be run directly.
Hardware Assisted Paravirtualized Guest Junos OS
Provides the user with the benefits of platform virtualization along with the default performance and functionality. Paravirtualization is a virtualization technique in which a software component similar to the underlying hardware component resides in the VM and interacts with the hypervisor to execute many operations. In contrast to full virtualization, this technique reduces the overhead of virtualization in the VM.
Guest Junos OS to Serve as the Administrative Framework
The configurations, chassis control, communication with the host OS, and user interface command execution are managed by the guest Junos OS.
Storage Partitioning and Redundancy
An Internal solid-state drive (SSD) is used as boot media for operating the Routing Engine. Additional options such as USB storage and network boot are available for installation and recovery purposes. A set of two 50-GB SSDs is available for normal functioning of the Routing Engine. The Routing Engine requires both the SSDs to be functional. Storage partitioning is important for debugging the Routing Engine, for new installations, and for SSD replacement.
Of the two SSDs, one operates as the primary SSD and the other as the backup SSD. Two sets of software boot images--the current set and the alternate (or previous) set are available on the primary SSD. The system boots from the current set, while the alternate set contains the previous version of the software boot image. After a software upgrade, the new version of the software is available on the alternate set. When the device is rebooted after the upgrade, the alternate set becomes the new current set and the current set, which now carries an older version of the software image, becomes the alternate set. You can switch to alternate set by using the request vmhost software rollback command. Until a

312 software upgrade or a software rollback is performed, the system is programmed to boot from the same set of images on the disk. Both the SSDs are partitioned to provide host boot partition, root partition, and partition for the guest image storage. The host boot partition contains the boot loader, which is the software responsible for booting the OS, Linux kernel, and RAM file system. The root partition contains the root file system for the host OS. Figure 5 on page 312 shows the partitioning of SSDs.
Figure 5: SSD Partitioning
Each SSD partition contains more than one set of fully functional host software. In case of a boot failure on the primary SSD, the router can boot by using the snapshot available on the alternate SSD. This snapshot can be generated by a fresh installation or by using the request vmhost snapshot command. Starting in Junos OS Release 18.1R1, the Routing Engines on the MX240, MX480,MX960, MX2010, MX2020, and PTX5000 support Secure Boot. Starting in Junos OS Release 18.2R1, the Routing Engine on the MX2008 supports Secure Boot. The Routing Engines with Secure Boot support have both RAM and SSD upgraded to 128GB and 2x200GB respectively. The increased SSD size facilitates increased storage of core and log files. The following table provides information on the SSD size for different Routing Engines:

313

Devices MX240, MX480, and MX960
PTX5000 MX2010 and MX2020
MX2008 QFX10002-60C PTX10002-60C MX10008

Routing Engine model number RE-S-2200X6-64G-S RE-S-X6-64G-LT RE-S-X6-128G-S RE-P-2200-64G-S RE-PTX-X8-128G-S RE-MX2K-X8-64G RE-MX2K-X8-64G-LT RE-MX2K-X8-128G-S REMX2008-X8-64G-LT REMX2008-X8-128G-S RE-QFX10002-60C RE-PTX10002-60C RE-X10

SSD size 2x50GB 2x50GB 2x200GB 2x50GB 2x200GB 2x100GB 2x100GB 2x200GB 2x100GB 2x200GB 2x50GB 2x50GB 2x200GB

You can use the show vmhost hardware command to display the increased RAM size, SSD size, and other hardware information.
The following illustrations explains the partition of the host to facilitate the increased storage of core files and log files. Figure 6 on page 314 illustrates the partition of the host on MX240, MX480, MX960,

314 MX2008, and PTX5000 routers with the 200-GB SSDs. A virtual disk of size 56-GB will be allocated from VM partition to the guest as var-config.disk. The current size of this disk is 15-GB. Figure 6: Host partition table for Routing Engines with 200-GB SSDs
Figure 7 on page 314 illustrates the storage allocation of the guest VM. Figure 7: Partitioning of the guest VM
NOTE: For Routing Engines with 50GB SSD, the host partition remains as­is. Figure 8 on page 314 and Figure 9 on page 314 illustrates the host partition table and the storage allocation of the guest VM for the MX2010 and MX2020 routers respectively. Figure 8: Host partition table for Routing Engines on MX2010 and MX2020 routers with 100GB SSD
A virtual disk of size 32-GB is allocated from VM partition to the guest Junos OS as var-config.disk. Figure 9: Guest VM partition on MX2010 and MX2020 Routers

315
A reformatting of the SSD is required to implement the enhancement of the /var size. The upgrade can be implemented by any of the following methods:
· Installation from SSD Disk2-Boot the host OS from the backup disk (SSD Disk2) and install the junosvmhost-install-x.tgz image.
· Installation from USB
NTP and Time Zone
The date and time zones are synchronized from the administrative guest Junos OS to the host OS. Therefore, the timestamps in system log files of Junos OS and the host OS are synchronized.
Autorecovery
The automatic recovery (autorecovery) feature provides the following functions:
· Detecting corruptions in disk partitioning during system startup and attempting to recover partitions automatically
· Detecting corruptions in the Junos OS configuration during system startup and attempting to recover the configuration automatically, thereby ensuring that the operations and management are not disrupted.
· Detecting corruptions in Junos OS licenses during system startup and attempting to recover licenses automatically.
During the process of recovery, the host OS tries to launch the Junos VM from the image available on the primary disk. However, if the Junos VM fails to launch, the host OS attempts to launch the Junos VM from the snapshot of the host OS image and Junos OS image available in the backup disk, provided request vmhost snapshot was the last operation performed. If the backup disk does not contain the snapshot, the host OS attempts to launch the Junos VM from the software available in the alternate set in the primary disk, provided request vmhost upgrade was the last operation performed.
The autorecovery feature is enabled by default on the guest OS. If you need to disable autorecovery-- for example, to examine the failure state for debugging--use the following command:
user@host> set vmhost no-auto-recovery
Handling Reboot and Power Off
You can reboot the Routing Engine by using the request vmhost reboot command. This command reboots the Routing Engine by rebooting both the guest Junos OS and the host OS. However, reboot of the Routing Engine can be triggered because of various reasons. The events or the reasons that trigger a host OS reboot are different from those that trigger a guest OS reboot.

316
Guest OS reboot implies that only the Junos OS is rebooted, and that the host OS is up and running. The following are a few of the reasons that trigger a guest OS reboot: · Reboot due to panic · VJUNOS reboot--Guest OS reboot after a shutdown. · VJUNOS watchdog from host--Guest reboot due to emulated watchdog timer expiry Host OS reboot implies that both the host OS and the guest OS (here, Junos OS) are rebooted. The following are a few reasons that trigger a host OS and guest OS reboot: · Hypervisor reboot · Power cycle or power failure · Reboot due to exception. · Reset-button reset--Reboot triggered by the pressing of the reset button on the front panel. · Thermal shutdown · Watchdog--Reboot due to PCH watchdog timer expiry You can find the reason for the reboot by using the show chassis routing-engine command or the show vmhost uptime command. For example:
host@router> show chassis routing-engine 0 | match "Last reboot reason" Last reboot reason 0x4000:VJUNOS reboot

host@router> show vmhost uptime re0 | match "Vmhost last reboot reason" Vmhost last reboot reason: 0x2000:hypervisor reboot

If the Routing Engine finishes booting and if you need to power off the router again, run the request vmhost power-off command. If you want the Routing Engine to reboot, use the request vmhost reboot command.
Release History Table
Release Description

18.2

Starting in Junos OS Release 18.2R1, the Routing Engine on the MX2008 supports Secure Boot.

317
RELATED DOCUMENTATION request vmhost snapshot | 889 request vmhost reboot | 887 request vmhost power-off | 883
Boot Process for Routers with VM Host Support
IN THIS SECTION Booting for the First Time | 317 Boot Sequence | 317 Understanding Console Port | 318 Understanding Hostnames Synchronization | 318
The boot process involves configuring the basic parameters through the console port and filename synchronization.
Booting for the First Time
When you power on a device for the first time, the router initiates the boot process. After hardware and field-programmable gate array (FPGA) level initialization is complete, the Unified Extensible Firmware Interface (UEFI) selects the boot device to launch the host OS. The host OS launches the default guest Junos OS, which is the administrative context for the user. After the device has powered on completely, a login prompt is displayed on the console port.
Boot Sequence
The Routing Engine boots from the storage media in the following sequence: · USB

318
· Solid-state Drive 1 (SSD1) · Solid-state Drive 1 (SSD2) · Preboot Execution Environment (PXÈ)
Understanding Console Port
To perform the initial configuration, you need to connect a terminal or laptop computer to the router through the console port, which is a serial port on the front of the router. The console port is the management port used by administrators to log in to Junos OS directly--that is, without using a network connection. Two universal asynchronous receiver/transmitter (UART) ports are connected to the midplane to provide CTY access to line cards. At any time, two ports can be active for the CTY application. These ports are available to the Junos VMs for configuration. For more information about configuring the router's basic properties, see Accessing a Junos OS Device the First Time.
Understanding Hostnames Synchronization
A hostname provides a unique identification for a router on the network. Junos OS uses the configured hostname as part of the command prompt, to prepend log files and other accounting information, as well as in other places where knowing the device identity is useful. Although Junos OS supports a maximum hostname length of 255 characters, the host OS supports hostnames that have only 64 characters or less. Therefore, hostnames need to be synchronized between Junos OS and the host OS. Keep in mind the following conditions when you synchronize the hostname configured on Junos OS with that on the host OS: · If the Junos OS-configured hostname has less than or equal to 58 characters, then the hostname
supported by the host OS (Linux) has the format Junos hostname-node. For example, if the Junos OS-configured hostname is xx..xx, the hostname is xx..xx-node. · If the Junos OS-configured hostname is greater than 58 characters in length, then the synchronization process truncates characters from the 59th character onward and replaces the truncated characters with -node.

319
RELATED DOCUMENTATION Creating an Emergency Boot Device for Routing Engines with VM Host Support | 328 vmhost | 578 request vmhost reboot | 887 request vmhost power-off | 883 Creating an Emergency Boot Device for Routing Engines with VM Host Support | 328
Installing, Upgrading, Backing Up, and Recovery of VM Host
IN THIS SECTION VM Host Upgrade | 320 VM Host Rollback | 322 VM Host Snapshot | 324
You can install the Junos OS software package and host software package on the device. The following installation options are available:
NOTE: The VM Host installation works differently on the QFX10002-60C switch and PTX10002-60C router. See "Installing Software Packages on QFX Series Devices" on page 151 and Installing the Software on PTX10002-60C Routers for more details. However, the information on the rollback and snapshot features work the same on QFX10002-60C switches and PTX10002-60C routers.
· Fresh installation-- This installation method can be used for factory installation as well as for recovery after corruption. Fresh installation can be done using Preboot Execution Environment (PXE)/NetBoot or a USB install media package. This method of installation installs the host OS, tools, and the Junos VMs. A PXE boot is an environment to boot devices using a network interface independent of available data storage devices or installed operating systems. The PXE environment is built on a foundation of

320
Internet protocols and services . These include TCP/IP, DHCP, and TFTP. This method of installation mostly used for installing the operating system on a device, without depending on the state of the internal media. The required software for network installation is stored on a TFTP server. PXE boot method supports remote installation thereby overcoming the need for an in-person assistance for installation. For more information, see "Copying VM Host Installation Package to the PXE Boot Server" on page 325. After you copy the VM Host Installation Package to the PXE Boot Server, you can use the request vmhost reboot network command and reboot the device to install the software. The device boots from the PXE server and installs the software on both the SSDs. You can choose to use the USB disk installation method when the device fails to reboot because of internal media failure or when there is no installed Junos OS. For more information, see "Creating an Emergency Boot Device for Routing Engines with VM Host Support" on page 328. On a fresh installation using USB, the following directories are populated with the Junos OS image on both the SSDs: · Current.p
· Backup.p
· Backup.b
· Regular installation-- This installation method is generally for an upgrade or a downgrade. This procedure can be used to install the runtime installation package on the currently running Junos VM to upgrade or downgrade relevant components. Junos VM performs the dependency check to identify the software components that require an upgrade or a downgrade to ensure compatibility.
NOTE: The RE-S-X6-64G-LT and RE-MX2K-X8-64G-LT Routing Engines are restricted to boot only the Junos OS with upgraded FreeBSD Limited image. They fail to boot if you try to install or upgrade the device with an image other than the Limited image, which begins with the junosvmhost-install prefix.
VM Host Upgrade
Every Junos OS release is a group of files bundled together. The Routing Engines RE-MX-X6, RE-MX-X8, and RE-PTX-X8 support only the 64-bit version of Junos OS.

321
NOTE: If you have important files in directories other than /config and /var, copy the files to a secure location before upgrading the device. The files under /config and /var (except /var/etc) are preserved after the VM host upgrade.
NOTE: Before installing software on a device that has one or more custom YANG data models added to it, back up and remove the configuration data corresponding to the custom YANG data models from the active configuration. For more information see "Managing YANG Packages and Configurations During a Software Upgrade or Downgrade" on page 118.
In order to perform VM Host upgrade, use the junos-vmhost-install-x.tgz image. This upgrade installs the host image along with the compatible Junos OS.
NOTE: To upgrade the Junos OS on RE-S-X6, RE-MX-X8, and RE-PTX-X8 Routing Engines, always use the VM Host Installation Package. Do not use the jinstall package.
The following example illustrates the upgrade operation. You can Install multiple software packages and software add-on packages at the same time.
user@host> > request vmhost software add /var/tmp/junos-vmhost-install-ptx-x86-64-15.1F5S2.8.tgz Initializing...
Verified os-libs-10-x86-64-20160616 signed by PackageProductionEc_2016 Mounting os-libs-10-x86-64-20160616.329709_builder_stable_10 .... Transfer Done Transfer /packages/db/pkginst.13874/junos-vmhost-install*.tgz Transfer Done Starting upgrade ... Preparing for upgrade... /tmp/pkg-0mc/unpack/install/ ... ... Cmos Write successfull for Boot_retry ... upgrade complete. A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY.

322 Use the 'request vmhost reboot' command to reboot the system

VM Host Rollback
You can revert to the software version that was loaded at the last successful request vmhost software add operation. You can roll back to the previous set of software packages, including the host OS packages, by using the request vmhost software rollback command.
The following example illustrates the software rollback operation. The Routing Engine that has booted from the primary disk by using the set p had booted using the set b before the upgrade.

user@host> show vmhost version

Current root details,

Device sda, Label: jrootp_P, Partition: sda3

Current boot disk: Primary

Current root set: p

UEFI

Version: NGRE_v00.53.00.01

Primary Disk, Upgrade Time: Wed Feb 24 17:51:53 UTC 2016

Version: set p

VMHost Version: 2.951

VMHost Root: vmhost-x86_64-15.1I20160210_2212_builder

VMHost Core: vmhost-core-x86_64-15.1I20160210_2212_builder

kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt

Junos Disk: junos-install-x86-64-15.1F5.5

Version: set b

VMHost Version: 2.953

VMHost Root: vmhost-x86_64-15.1F520160222_1052_builder

VMHost Core: vmhost-core-x86_64-15.1F520160222_1052_builder

kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt

Junos Disk: junos-install-x86-64-15.1F5.6

user@host> request vmhost software rollback

Current root details,

Device sda, Label: jrootp_P, Partition: sda3

Finding alternate root for rollback

Rollback to software on jrootb_P ...

sh /etc/install/mk-mtre-rollback.sh jrootb_P b

Mounting device in preparation for rollback...

323
Updating boot partition for rollback... Rollback complete, please reboot the node for it to take effect. Cmos Write successfull Cmos Write successfull for Boot_retry Cmos Write successfull for Boot_retry

user@host> show vmhost version

Current root details,

Device sda, Label: jrootp_P, Partition: sda3

Current boot disk: Primary

Current root set: p

UEFI

Version: NGRE_v00.53.00.01

Primary Disk, Upgrade Time: Wed Feb 24 17:51:53 UTC 2016

Pending reboot.

Version: set p

VMHost Version: 2.951

VMHost Root: vmhost-x86_64-15.1I20160210_2212_builder

VMHost Core: vmhost-core-x86_64-15.1I20160210_2212_builder

kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt

Junos Disk: junos-install-x86-64-15.1F5.5

Version: set b

VMHost Version: 2.953

VMHost Root: vmhost-x86_64-15.1F520160222_1052_builder

VMHost Core: vmhost-core-x86_64-15.1F520160222_1052_builder

kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt

Junos Disk: junos-install-x86-64-15.1F5.6

user@host> request vmhost reboot Reboot the vmhost ? [yes,no] (no) yes
warning: Rebooting re1 Initiating vmhost reboot... ok Initiating Junos shutdown... shutdown: [pid 9733] Shutdown NOW!
ok Junos shutdown is in progress...
*** FINAL System shutdown message ***

324 System going down IMMEDIATELY

user@host> show vmhost version

Current root details,

Device sda, Label: jrootb_P, Partition: sda4

Current boot disk: Primary

Current root set: b

UEFI

Version: NGRE_v00.53.00.01

Primary Disk, Upgrade Time: Wed Feb 24 17:51:53 UTC 2016

Version: set p

VMHost Version: 2.951

VMHost Root: vmhost-x86_64-15.1I20160210_2212_builder

VMHost Core: vmhost-core-x86_64-15.1I20160210_2212_builder

kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt

Junos Disk: junos-install-x86-64-15.1F5.5

Version: set b

VMHost Version: 2.953

VMHost Root: vmhost-x86_64-15.1F520160222_1052_builder

VMHost Core: vmhost-core-x86_64-15.1F520160222_1052_builder

kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt

Junos Disk: junos-install-x86-64-15.1F5.6

VM Host Snapshot
The snapshot feature enables you to create copies of the currently running and active file system partitions on a device.
On the device, you can back up the snapshot of the host OS image along with the Junos OS image. You can use the request vmhost snapshot command to create a VM host recovery snapshot on the backup disk.
Disk Recovery Using the VM Host Snapshot
If the state of the primary disk (disk1) is good and the backup disk (disk2) has to be recovered then use the request vmhost snapshot command to recover the backup disk assuming the Routing Engine is booted from the primary disk. If the state of the secondary disk is not known or the file systems in disk are not in a consistent state, then include partition option in the command i.e. request vmhost snapshot partition.

325
If the state of the backup disk (disk2) is good and the primary disk (disk1) has to be recovered then use the request vmhost snapshot recovery command to recover the primary disk assuming the Routing Engine is booted from the backup disk. If the state of the primary disk is not known or the partition tables are in bad condition, then include partition option in the command i.e. request vmhost snapshot recovery partition. To boot from desired disk, you can execute request vmhost reboot { disk1, disk2} command.
RELATED DOCUMENTATION Salient Features of the Routing Engines with VM Host Support | 310 request vmhost software add | 894 request vmhost software rollback | 905 request vmhost snapshot | 889 show vmhost snapshot | 941
Copying VM Host Installation Package to the PXE Boot Server
You can install the host OS, tools, and the Junos virtual machines (VMs) on the devices with RE-MX-X6, RE-MX-X8,RE-PTX-X8, and RE-QFX10002-60C, and RE-PTX10002-60C Routing Engines by using the Preboot Execution Environment (PXE) boot method. This is one of the methods used for a fresh installation. A PXE boot prepares a client/server environment to boot devices by using a network interface that is independent of available data storage devices or installed operating systems. The image of the operating system is stored on a TFTP server. To copy the installation packages to the PXE boot server: 1. Copy the downloaded installation media to the /var/tmp directory in the PXE boot server.
scp /volume/build/junos/15.1/release/15.1F3.9/ship/junos-vmhost-install-netx86-64-15.1F3.9.tgz user@host:/var/tmp/

326
2. Log in to the PXE boot server and verify the installation file.
user@host> ls -lh junos-vmhost-install-net-x86-64-15.1F3.9.tgz -rw-r--r-- 1 root root 1.8G Oct 24 00:42 junos-vmhost-install-netx86-64-15.1F3.9.tgz
3. Extract the junos-vmhost-install-net TAR file.
user@host> tar xvzf junos-vmhost-install-net-x86-64-15.1F3.9.tgz ­C /var/tmp contents/ contents/junos-vmhost-install.tgz contents/vmhost-install-net-x86_64-15.1I20151019_1021_builder.tgz manifest manifest.certs manifest.ecerts manifest.esig manifest.sig package.xml
4. Remove the previously installed files, if any, from the /tftpboot directory.
user@host> rm -f /tftpboot/{vmhost-version.sh,bootpxe64.efi,vmhostversion,grub.cfg,initramfs,vmlinuz} user@host>ls -lh /tftpboot// total 45M
rw-r--r-- 1 root root 690K Sep 8 13:22 bootpxe.efi -rw-rw-r-- 1 930 930 45M Oct 20 01:51 vmhost-install-netx86_64-15.1I20151019_1021_builder.tgz
5. Extract the network installation package.
user@host> tar xvzf /var/tmp/contents/vmhost-install-net-x86_64-15.1I20151019_1021_builder.tgz -C /tftpboot/ ./ ./vmhost-version.sh ./bootpxe64.efi ./vmhost-version ./grub.cfg ..

327
... -rw-rw-r-- 1 930 930 45M Oct 20 01:51 vmhost-install-netx86_64-15.1I20151019_1021_builder.tgz -rw-rw-r-- 1 930 930 6 Oct 20 01:51 vmhost-version -rwxrwxr-x 1 930 930 416 Oct 20 01:51 vmhost-version.sh -rw-r--r-- 1 930 930 6.9M Oct 20 01:51 vmlinuz
6. Rename or delete the previously installed root file system/scripts from the /var/install directory. Create a new /var/install directory.
user@host>mv /var/install /var/install_old user@host>mkdir /var/install
7. Extract the installation package.
user@host>tar xvzf /var/tmp/contents/junos-vmhost-install.tgz -C /var/install ./ ./vmhost-pkgs-version ./vm/ ./vm/note ./vm/grub.cfg.ngre ./vm/vsmartd-1.0-0.x86_64.rpm ./vm/re_fpga-1.0-0.x86_64.rpm ./vm/veccd-1.0-0.x86_64.rpm ./vmhost-version.sh ./vmhost/ ./vmhost/vmhost-x86_64-15.1I20151019_1021_builder.img.gz ... ... ./junos/junos-mtre-upgrade.sh ./vmhost-core-x86_64-15.1I20151019_1021_builder.tgz ./junos/ ./junos/junos-install-x86-64-15.1F3.9.img.gz
8. Set permissions for the files in the /var/install and /tftpboot directories.
user@host> chown root:root /tftpboot/* user@host>chmod a+rwx /tftpboot/*

328
user@host>chown -R root:root /var/install user@host>chmod -R a+rwx /var/install 9. Exit the PXE boot server.
user@host> exit
RELATED DOCUMENTATION Installing, Upgrading, Backing Up, and Recovery of VM Host | 319 Creating an Emergency Boot Device for Routing Engines with VM Host Support | 328
Creating an Emergency Boot Device for Routing Engines with VM Host Support
If Junos OS on your device is damaged during loading in a way that prevents it from loading completely, you can use the emergency boot device to revive the device. The emergency boot device repartitions the primary disk and reloads a fresh installation of Junos OS. For RE-MX-X6, RE-MX-X8, RE-PTX-X8, and RCBPTX Routing Engines, you can use a USB storage device with at least 8 GB of free space to create an emergency boot device. To create an emergency boot device on a device with RE-MX-X6, RE-MX-X8, RE-PTX-X8, RCBPTX, REQFX10002-60C, and RE-PTX10002-60C Routing Engines: 1. Copy the installation media into the device's /var/tmp directory. 2. Insert the USB storage device into the device's USB port. 3. In the UNIX shell, navigate to the /var/tmp directory:
start shell cd /var/tmp 4. Log in as su:

329
Super User (su) is one of the predefined login classes with preset permissions.
su [enter] password: [enter SU password] 5. Gunzip the copied file. For example, to convert junos-vmhost-install-usb-mx-x86-64-15.1F6.8.img.gz to junos-vmhostinstall-usb-mx-x86-64-15.1F6.8.img, , use the following command: gunzip junos-vmhost-install-usbmx-x86-64-15.1F6.8.img.gz 6. Issue the following command:
dd if=/path/to/downloaded.img of=/dev/devicenode bs=4M
where: · devicenode--Refers to the name of the removable media of the emergency boot device. For
names of storage media, see "Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, PTX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers)" on page 394. · downloaded.img--Refers to the installation media copied to the /var/tmp directory. For example, junos-vmhost-install-usb-ptx-x86-64-15.1F6.8.img. The following code example can be used to create an emergency boot device by using a USB storage device:
dd if=/path/to/junos-vmhost-install-usb-mx-x86-64-15.1F6.8.img of=/dev/da0 bs=4M
NOTE: In the dd command, use junos-vmhost-install-usb-mx-86 for RE-MX-X6 and RE-MXX8 Routing Engines and junos-vmhost-install-ptx-86 for RE-PTX-X8 Routing Engine respectively.
7. Log out as su:
exit

330
RELATED DOCUMENTATION Boot Process for Routers with VM Host Support | 317
Upgrading the SSD Firmware on Routing Engines with VM Host Support
Starting in Junos OS Release 17.2R1, you can upgrade the solid-state drive (SSD) firmware on MX Series routers with the RE-S-X6-64G and RE-MX2K-X8-64G Routing Engines, on QFX10002-60C switches with the RE-QFX10002-60C Routing Engines, and PTX10002-60C routers with the RE-PTX10002-60C Routing Engines. A set of two SSDs, disk1 and disk2 , is available for normal functioning of the Routing Engine. This topic shows how to perform the upgrade.
NOTE: You must upgrade SSD firmware only under the direction of a Juniper Networks support representative.

NOTE: On QFX10002-60C switches, you can upgrade firmware only for the FPGA and BIOS, not the SSD.
Before you begin upgrading the firmware, check the current firmware version of the SSD.

user@host> show system firmware

Part

Type

Tag

Routing Engine 0 Routing Engine 0 Routing Engine 0 Routing Engine 0 Routing Engine 1

RE BIOS 0 RE FPGA 1 RE SSD1 4 RE SSD2 5
0

Current Available Status

version version

0.45

0.53

OK

36.0.0 41.0

OK

12028

12029

OK

12028

12029

OK

1.4

OK

If the value of Current version is less than the value of Available version, then you can use the following procedure for the SSD firmware upgrade.
To upgrade SSD firmware:
1. Copy the jfirmware package to the device.

331

If the file has been obtained from JTAC, use FTP or SCP to load the firmware file on the device. Save the file in the /var/tmp directory.
user@host> request system software add ftp://ftp.juniper.net/private/system/jfirmware-17.1R2signed.tgz 2. Upgrade the SSD disk1 firmware.
NOTE: In releases before Junos OS Release 18.3R1, you must upgrade the SSD on a primary Routing Engine only. For upgrading firmware on the backup Routing Engine, switch primary role by using the following command and then log in to the backup Routing Engine, which is now the new primary Routing Engine:. user@host> request chassis routing-engine master switch
Starting in Junos OS Release 18.3R1, you can upgrade the SSD firmware on the primary and backup Routing Engines.

To initiate the upgrade, use the following command:

user@host> request system firmware upgrade re ssd disk1

Part

Type

Tag Current Available

Status

version version

Routing Engine 0 RE SSD1 4

12028

12029

OK

Perform indicated firmware upgrade ? [yes,no] (no) yes

Firmware upgrade initiated, use "show system firmware" to monitor status.

Monitor the upgrade status by using the show system firmware command.

user@host> show system firmware

Part

Type

Tag

Routing Engine 0 Routing Engine 0 Routing Engine 0

RE BIOS 0 RE FPGA 1 RE SSD1 4

Current Available Status

version version

0.45

0.53

OK

36.0.0 41.0

OK

12028

12029

OK

332

Routing Engine 0 Routing Engine 1

RE SSD2 5 0

12028

12029

OK

1.4

OK

user@host> show system firmware

Part

Type

Tag

Routing Engine 0 Routing Engine 0 Routing Engine 0 SUCCESSFULLY Routing Engine 0 Routing Engine 1

RE BIOS 0 RE FPGA 1 RE SSD1 4
RE SSD2 5 0

Current Available Status

version version

0.45

0.53

OK

36.0.0 41.0

OK

12029

12029

UPGRADED

12028

12029

OK

1.4

OK

After a successful upgrade, confirm that the current version and available version of the SSD firmware are identical. 3. Upgrade SSD Disk2 firmware. To initiate the upgrade, use the following command:

user@host> request system firmware upgrade re ssd disk2

Part Type Tag Current Available Status

version version

Routing Engine 0 RE SSD2 5 12028

12029

OK

Perform indicated firmware upgrade ? [yes,no] (no) yes

Firmware upgrade initiated, use "show system firmware" to monitor status.

Monitor the upgrade status by using the show system firmware command.

user@host> show system firmware

Part

Type

Tag

Routing Engine 0 Routing Engine 0 Routing Engine 0 SUCCESSFULLY

RE BIOS 0 RE FPGA 1 RE SSD1 4

Current Available Status

version version

0.45

0.53

OK

36.0.0 41.0

OK

12028

12029

UPGRADED

333

Routing Engine 0 Routing Engine 1

RE SSD2 5 0

12028 1.4

12029

PROGRAMMING OK

user@host> show system firmware

Part

Type

Tag

Routing Engine 0 Routing Engine 0 Routing Engine 0 SUCCESSFULLY Routing Engine 0 SUCCESSFULLY Routing Engine 1

RE BIOS 0 RE FPGA 1 RE SSD1 4
RE SSD2 5
0

Current Available

Status

version version

0.45

0.53

OK

36.0.0

41.0

OK

12029

12029 UPGRADED

12029

12029 UPGRADED

1.4

OK

After a successful upgrade, confirm that the current version and available version of the SSD firmware are identical.
Release History Table Release Description

17.2R1

Starting in Junos OS Release 17.2R1, you can upgrade the solid-state drive (SSD) firmware on MX Series routers with the RE-S-X6-64G and RE-MX2K-X8-64G Routing Engines, on QFX10002-60C switches with the RE-QFX10002-60C Routing Engines, and PTX10002-60C routers with the RE-PTX10002-60C Routing Engines.

Upgrading the i40e NVM Firmware on Routing Engines with VM Host Support
In order to install VM Host image based on Linux WRL9, you have to upgrade the i40e NVM firmware to version 6.01. Starting in Junos OS Release 19.3R1, in order to install VM Host image based on Linux WRL9, you have to upgrade the i40e NVM firmware to version 6.01. Table 15 on page 334 lists the Junos OS releases which support i40e NVM firmware upgrade.

334

Table 15: Junos OS Releases which Support i40e NVM Firmware Upgrade

Platform

15.x

16.x

17.x

18.x

PTX5000

15.1F6-S11 16.1R7

17.1R3 / 17.2R3 / 17.3R3 / 17.4R2

18.1R1 / 18.2R1 / 18.3R1 / 18.4R1

PTX3000

Not applicable

Not applicable

Not applicable

18.2R3 / 18.3R3 / 18.4R2

MX240 / MX480 / MX960 / MX2010 / MX2020

15.1F6-S11

16.1R7

17.1R3 / 17.2R3 / 17.3R3 / 17.4R2

18.1R1 / 18.2R1 / 18.3R1 / 18.4R1

MX2008

Not applicable

Not applicable

Not applicable

18.2R3 / 18.3R3 / 18.4R2

MX10016/ MX10008 PTX10016/ MX10008

Not applicable

Not applicable

Not applicable

18.2R3 / 18.3R3 / 18.4R2

19.x 19.1R1 or later
19.1R2 / 19.2R1
19.1R1 or later
19.1R2 / 19.2R1
19.1R2 / 19.2R1

You can install older Junos OS images on the Routing Engine with an upgraded i40e NVM firmware as it supports i40e 2.4.3 driver versions. If you install an older version of the VM Host image, which is not listed in Table 16 on page 335, using USB, the Routing Engine does not start up properly. In such a case, you can reinstall the VMHost image with a version which supports the new i40e NVM firmware.

335

Table 16: Junos OS Versions which Support i40e 2.4.3 Driver Versions

Platform

i40e-1.1.2 3/ NVM-4.2 6 Support

i40e-2.4.3/ NVM-6.01 Support

PTX5000

15.1F3

15.1F6S11

16.1R7

17.1R3/ 17.2R3 / 17.3R3/ 17.4R2

18.1R1 / 18.2R3 / 18.3R1 / 18.4R1

19.1R1 or later

PTX3000

16.1R4

Not

16.1R7

applicable

17.3R3S6 / 17.4R2-S7

18.2R3S8 / 18.2R3 / 18.3R3 / 18.4R2

19.1R2/ 19.2R1

MX240/MX480/ MX960

15.1F3

15.1F6S11

16.1R7

17.1R3 / 17.2R3 / 17.3R3 / 17.4R2

18.1R1 / 18.2R1 / 18.3R1 / 18.4R1

19.1R1 or later

MX2010/MX2020

15.1F5-S1 15.1F6S11

16.1R7

17.1R3 / 17.2R3 / 17.3R3 / 17.4R2

18.1R1 / 18.2R1 / 18.3R1 / 18.4R1

19.1R1 or later

MX2008

15.1F7

Not applicable

Not applicable

17.2R3 / 17.3R3 / 17.4R2

18.1R1 / 18.2R1 / 18.3R1 / 18.4R1

19.1R1 or later

MX10016/ MX10008 PTX10016/ MX10008

18.2R1

Not

Not

Not

applicable applicable applicable

18.2R1 / 18.3R1 / 18.4R1

19.1R1 or later

i40e-NVM upgrade is optional for the following platforms:

336
· MX10003 · MX10016/MX10008 with JNP10K-RE1 - shown in the cli output as RE X10 · PTX10016/PTX10008 with JNP10K-RE0 - shown in the cli output as RE-PTX-2X00x4 · PTX10002-XX · QFX1000, QFX10002 · QFX5000 · EX platforms
NOTE: · You must upgrade i40e NVM firmware only under the direction of a Juniper Networks
support representative. Once you upgrade the NVM firmware, a downgrade action is not supported. For latest update, you can refer https://kb.juniper.net/. · You must implement this procedure with a router console access. Also, you have to perform power cycling of the routing Engine multiple times during the firmware upgrade process.
Before you begin upgrading the firmware, check the current firmware version of the i40e NVM.

user@host> show system firmware

Part

Type

Routing Engine 0 RE BIOS Routing Engine 1 RE BIOS Routing Engine 1 RE FPGA Routing Engine 1 RE SSD1 Routing Engine 1 RE SSD2 Routing Engine 1 RE i40e-NVM

Tag Current Available

version version

0

0.53.1

0

0.43

0.53

1

28.0.0

41.0

3

0.0.0

3

0.0.0

7

4.26

Status
OK OK OK OK OK OK

If the value of Current version is less than 6.01, then you can use the following procedure for the i40e NVM firmware upgrade.
To upgrade i40e NVM firmware on routers with single Routing Engine:
1. Upgrade the device with the Junos OS image version which supports i40e NVM firmware upgrade. See Table 15 on page 334. Copy and install the jfirmware-vmhost package to the device.

337

If the file has been obtained from JTAC, use FTP or SCP to load the firmware file on the device. Save the file in the /var/tmp directory.
user@host> request vmhost software add /var/tmp/jfirmware-vmhost-x86-64-19.2R1.tgz 2. Upgrade the NVM firmware.
To initiate the upgrade, use the following command:

user@host> request system firmware upgrade re i40nvm

Part

Type

Tag Current Available

version version

Routing Engine 1 RE i40e-NVM 7

4.26

6.01

Perform indicated firmware upgrade ? [yes,no] (no) yes

Status OK

Firmware upgrade initiated, use "show system firmware" after reboot to verify the firmware version

Monitor the upgrade status by using the show system firmware command. If the upgrade is initiated the output displays PROGRAMMING (0%) as the status. However, note that the status PROGRAMMING (0%) does not increment during the process.

user@host> show system firmware

Part

Type

Routing Engine 0 RE BIOS Routing Engine 1 RE BIOS Routing Engine 1 RE FPGA Routing Engine 1 RE SSD1 Routing Engine 1 RE SSD2 Routing Engine 1 RE i40e-NVM

Tag Current Available Status

version version

0

0.53.1

OK

0

0.43

OK

1

28.0.0

OK

3

0.0.0

OK

3

0.0.0

OK

7

4.26 6.01

PROGRAMMING

(0%)

3. Reboot the device by using the request vmhost reboot command.

user@host> request vmhost reboot
4. Verfiy the progress of i40e NVM upgrade on the console. You may have to perform power recycle of the Routing Engine multiple times. When you are prompted for a power cycle on your console, use external power cycle for power cycling the Routing Engine.

338
The following message is displayed on the console prompting you to perform a power cycle:
"Please Power Cycle your system now and run the NVM update utility again to complete the update. Failure to do so will result in an incomplete NVM update. Upgrade complete please power reboot You may notify to power reboot again after reboot if required" 5. After a successful upgrade, verify the version of the firmware.
NOTE: The Current version is displayed as 6.1 instead of 6.01.

user@host> show system firmware

Part

Type

Tag Current Available Status

version version

Routing Engine 0 RE BIOS

0

0.53.1

OK

Routing Engine 1 RE BIOS

0

0.43

OK

Routing Engine 1 RE FPGA

1

28.0.0

OK

Routing Engine 1 RE SSD1

3

0.0.0

OK

Routing Engine 1 RE SSD2

3

0.0.0

OK

Routing Engine 1 RE i40e-NVM 7 6.1

6.01

OK

NOTE: In case, you have run the request vmhost snapshot command with a Junos OS image which does not support i40e NVM firmware upgrade, (if the SSD recovery snapshot has a Junos OS version older than the Junos OS versions mentioned in Table 16 on page 335) we recommend you to take a snapshot using the request vmhost snapshot command again. Hence, in case of a recovery process, the SSD recovery snapshot will have a Junos OS image which supports NVM 6.01.
On routers with dual Routing Engines, you must use the request chassis cb (offline | online) slot slotnumber to power cycle the Routing Engine. Thereby, you can avoid using an external power cycler and avoid abrupt power cycling of backup RE, which may cause file system errors.
To upgrade i40e NVM firmware on routers with dual Routing Engines:
NOTE: You must disable GRES before proceeding with the upgrade procedure.

339

1. Upgrade the device with the Junos OS image version which supports i40e NVM firmware upgrade. See Table 15 on page 334.
Copy and install the jfirmware-vmhost package to the device.
If the file has been obtained from JTAC, use FTP or SCP to load the firmware file on the device. Save the file in the /var/tmp directory.
user@host> request vmhost software add /var/tmp/jfirmware-vmhost-x86-64-19.2R1.tgz
2. Upgrade the NVM firmware.
To initiate the upgrade, use the following command:

user@host> request system firmware upgrade re i40nvm

Part

Type

Tag Current Available

version version

Routing Engine 1 RE i40e-NVM 7

4.26

6.01

Perform indicated firmware upgrade ? [yes,no] (no) yes

Status OK

Firmware upgrade initiated, use "show system firmware" after reboot to verify the firmware version

Monitor the upgrade status by using the show system firmware command. If the upgrade is initiated the output displays PROGRAMMING (0%) as the status. However, note that the status PROGRAMMING (0%) does not increment during the process.

user@host> show system firmware

Part

Type

Routing Engine 0 RE BIOS Routing Engine 1 RE BIOS Routing Engine 1 RE FPGA Routing Engine 1 RE SSD1 Routing Engine 1 RE SSD2 Routing Engine 1 RE i40e-NVM

Tag Current Available Status

version version

0

0.53.1

OK

0

0.43

OK

1

28.0.0

OK

3

0.0.0

OK

3

0.0.0

OK

7

4.26 6.01

PROGRAMMING

(0%)

3. Switch to the backup Routing Engine by using the request chassis routing-engine master switch command to switch primary role to other RE (i.e, RE1).

340
NOTE: This step is necessary, because in Step 6 you have to power cycle the Routing Engine which is undergoing the NVM upgrade (i.e, RE0) from RE1
user@host> request chassis routing-engine master switch Toggle mastership between routing engines ? [yes,no] (no) yes
Resolving mastership... Complete. The other routing engine becomes the master.
4. Reboot the device by using the request vmhost reboot command from the Routing Engine which is undergoing the NVM upgrade (i.e, RE0).
user@host> request vmhost reboot
5. Monitor the console output. You may have to perform power recycle of the Routing Engine multiple times. When you are prompted for a power cycle on your console, use external power cycle for power cycling the Routing Engine. Or, you can use the command request chassis cb slot slot offline as described in Step 6. The following message is displayed on the console prompting you to perform a power cycle:
"Please Power Cycle your system now and run the NVM update utility again to complete the update. Failure to do so will result in an incomplete NVM update. Upgrade complete please power reboot You may notify to power reboot again after reboot if required"
6. From RE1, power cycle the RE0 using following command request chassis cb slot slot offline.

341
To power off RE0, use the command request chassis cb slot 0 offline and to power on RE0, use the command request chassis cb slot 0 online.
user@host> request chassis cb slot 0 offline Offline initiated, use "show chassis environment cb" to verify
user@host> request chassis cb slot 0 online Online initiated, use "show chassis environment cb" to verify 7. After a successful upgrade, verify the version of the firmware.
NOTE: The Current version is displayed as 6.1 instead of 6.01.

user@host> show system firmware

Part

Type

Tag Current Available Status

version version

Routing Engine 0 RE BIOS

0

0.53.1

OK

Routing Engine 1 RE BIOS

0

0.43

OK

Routing Engine 1 RE FPGA

1

28.0.0

OK

Routing Engine 1 RE SSD1

3

0.0.0

OK

Routing Engine 1 RE SSD2

3

0.0.0

OK

Routing Engine 1 RE i40e-NVM 7 6.1

6.01

OK

NOTE: In case, you have run the request vmhost snapshot command with a Junos OS image which does not support i40e NVM firmware upgrade, (if the SSD recovery snapshot has a Junos OS version older than the Junos OS versions mentioned in Table 16 on page 335) we recommend you to take a snapshot using the request vmhost snapshot command again. Hence, in case of a recovery process, the SSD recovery snapshot will have a Junos OS image which supports NVM 6.01.

342
8. Similarly, while upgrading i40e NVM on RE1, power cycle RE1 from RE0.
user@host> request chassis cb slot 1 offline Offline initiated, use "show chassis environment cb" to verify

user@host> request chassis cb slot 1 online Online initiated, use "show chassis environment cb" to verify
9. You need to perform this step only if the image you downloaded does not contain debugfs based mechanism to stop LLDP.
Download the lldp-patch-for-i40e-upgrade.tgz package. Copy and install the file in the /var/tmp/ directory on each Routing Engine.

user@host> request vmhost software add /var/tmp/lldp-patch-for-i40eupgrade.tgz Verified lldp-patch-for-i40e-upgrade signed by PackageDevelopmentEc_2018 method ECDSA256+SHA256 [ re_name = RE-PTX-2X00x8 ] Pushing script(s) to host ... Install the script(s) under host-os.... Script(s) copy done

user@host>show version | match lldp lldp-patch-for-i40e-upgrade
10. Reboot the device by using the request vmhost reboot command. The upgrade process is complete when the Routing Engine comes back online.

user@host> request vmhost reboot

Release History Table Release Description

19.3R1

Starting in Junos OS Release 19.3R1, in order to install VM Host image based on Linux WRL9, you have to upgrade the i40e NVM firmware to version 6.01.

343
Disabling Autorecovery on Routing Engines with VM Host Support
The autorecovery feature helps recover the Junos OS automatically in the event of a corruption, thereby ensuring that the Junos OS is available for operations and management always. The host Junos OS tries to launch the Junos VM from the image available on the primary disk. However, if the guest Junos OS fails to launch, the host OS attempts to launch the Junos VM from the snapshot of the host OS image and Junos OS image available in the backup disk, provided request vmhost snapshot was the last operation performed. If the backup disk does not contain the snapshot, the host OS attempts to launch the Junos VM from the software available in the alternate set in the primary disk, provided request vmhost upgrade was the last operation performed. The autorecovery feature is enabled by default on the guest Junos OS. For debugging purposes, if you do not want the host to recover the Junos VM automatically, you can disable the auto-recovery by the host. To disable the guest auto-recovery, include the no-auto-recovery statement at the [edit vmhost] hierarchy level:
[edit vmhost] no-auto-recovery
RELATED DOCUMENTATION vmhost | 578
VM Host Operations and Management
With the virtualization of the Routing Engine, Junos OS supports new request and show commands associated with the host and hypervisor processes. The commands are related to: · Reboot, halt, and power management for the host. · Software upgrade for the host. · Disk snapshot for the host.

344
The following request commands are not available on the RE-MX-X6, RE-MX-X8, and RE-PTX-X8 Routing Engines: · request system halt · request system partition abort · request system power-off · request system power on The following commands can be used only for the guest Junos OS: · request system reboot · request system snapshot · request system software add · request system zeroize You can use the following new request vmhost commands on the host OS: · request vmhost cleanup · request vmhost file-copy · request vmhost halt · request vmhost hard-disk-test · request vmhost power-off · request vmhost power-on · request vmhost reboot · request vmhost snapshot · request vmhost software abort in-service-upgrade
NOTE: This command is not supported on the QFX10002-60C and PTX10002-60C devices.
· request vmhost software add · request vmhost software in-service-upgrade

345
NOTE: This command is not supported on the QFX10002-60C and PTX10002-60C devices. · request vmhost software rollback · request vmhost zeroize
RELATED DOCUMENTATION Routing Engines with VM Host Support | 309

5 CHAPTER
Installing and Upgrading the BIOS and Firmware
Upgrading BIOS and Firmware | 347 Installing and Upgrading Firmware | 351

347
Upgrading BIOS and Firmware
IN THIS SECTION Understanding BIOS Upgrades on SRX Series Devices | 347 Disabling Auto BIOS Upgrade on SRX Series Devices | 349
You can upgrade BIOS, back up the BIOS, and upgrade automatically on your SRX Series devices.
Understanding BIOS Upgrades on SRX Series Devices
IN THIS SECTION Understanding Manual BIOS Upgrade Using the Junos CLI | 347 Understanding Auto BIOS Upgrade Methods on SRX Series Devices | 349
Understanding Manual BIOS Upgrade Using the Junos CLI
For these SRX Series devices, the BIOS consists of a U-boot and the Junos loader. The SRX240, SRX300, and SRX320, and SRX650 Service Gateways also include a U-shell binary as part of the BIOS. Additionally, on SRX100, SRX110, SRX210, SRX220 and SRX240, SRX300, SRX320, SRX340, SRX345, and SRX380 Service Gateways, a backup BIOS is supported which includes a backup copy of the U-boot in addition to the active copy from which the system generally boots up. Table 17 on page 348 Lists the CLI commands used for manual BIOS upgrade.

348

Table 17: CLI Commands for Manual BIOS Upgrade

Active BIOS

Backup BIOS

request system firmware upgrade re bios

request system firmware upgrade re bios backup

BIOS upgrade procedure: 1. Install the jloader-srxsme package.
a. Copy the jloader-srxsme signed package to the device.

NOTE: The version of the jloader-srxsme package you install must match the version of Junos OS.

b. Install the package using the request system software add <path to jloader-srxsme package> nocopy no-validate command.

NOTE: Installing the jloader-srxsme package places the necessary images under directory/ boot.

2. Verify that the required images for upgrade are installed. Use the show system firmware to verify that the correct BIOS image version is available for upgrade.
3. Upgrade the BIOS (Active and backup) image. Active BIOS: a. Initiate the upgrade using the request system firmware upgade re bios command. b. Monitor the upgrade status using the show system firmware command.

NOTE: The device must be rebooted for the upgraded active BIOS to take effect.

Backup BIOS: a. Initiate the upgrade using the request system firmware upgade re bios backup command. b. Monitor the upgrade status using the show system firmware command.

349
Understanding Auto BIOS Upgrade Methods on SRX Series Devices
The BIOS version listed in the bios-autoupgrade.conf file is the minimum supported version. If the current device has a BIOS version earlier than the minimum compatible version, then the auto BIOS upgrade feature upgrades the BIOS automatically to the latest version. The BIOS upgrades automatically in the following scenarios: · During Junos OS upgrade through either the J-Web user interface or the CLI (using the request
system software add no-copy no-validate software-image). In this case, only the active BIOS is upgraded.
· During loader installation using TFTP or USB (using the install tftp:///software-image command). In this case, only the active BIOS is upgraded.
· During system boot-up. In this case, both the active BIOS and the backup BIOS are upgraded.
Disabling Auto BIOS Upgrade on SRX Series Devices
The auto BIOS upgrade feature is enabled by default. You can disable the feature using the CLI in configuration mode. To disable the automatic upgrade of the BIOS on an SRX Series device, use the chassis routing-engine bios command as following:
user@host# set chassis routing-engine bios no-auto-upgrade
NOTE: The command disables automatic upgrade of the BIOS only during Junos OS upgrade or system boot-up. It does not disable automatic BIOS upgrade during loader installation.
Starting in Junos OS Release 15.1X49-D70 and in Junos OS Release 17.3R1, the set chassis routingengine bios uninterrupt command is introduced on SRX300, SRX320, SRX340, and SRX345 devices to disable user inputs at U-boot and boot loader stage. The set chassis routing-engine bios uninterrupt command is introduced in Junos OS Release 20.1R1 for SRX380 Series devices. Starting in Junos OS Release 15.1X49-D120, the set chassis routing-engine bios uninterrupt command can be used on SRX300, SRX320, SRX340, and SRX345, devices to disable user inputs at U-boot, boot loader and and Junos-Kernel boot stage. The set chassis routing-engine bios uninterrupt command is introduced in Junos OS Release 20.1R1 on SRX380 Series devices.

350
To disable the user inputs at u-boot, boot loader and Junos Kernel boot stage, use the chassis routingengine bios command as following:
user@host# set chassis routing-engine bios uninterrupt
NOTE: To disable user inputs at U-boot and boot loader stage using the chassis routing-engine bios command, SRX devices must have u-boot version of v3.2 or a higher version, and loader version of v2.9 or a higher version. You can check the version number at console output when your device boots up as shown in the following sample:
U-Boot 2013.07-JNPR-3.4 (Build time: Aug 02 2017 - 18:57:37) FreeBSD/MIPS U-Boot bootstrap loader, Revision 2.9
You can also check the u-boot and loader version at Junos shell prompt as shown the following sample:
root@% kenv LINES="24" boot.ver="3.5" loader.name="FreeBSD/MIPS U-Boot bootstrap loader" loader.version="2.9" root@%

WARNING: On SRX Series devices, if both set system ports console insecure and set chassis routing-engine bios uninterrupt options are configured, there is no alternative recovery method available in case Junos OS fails to boot and the device might become unusable.

Release History Table

Release

Description

15.1X49-D70

Starting in Junos OS Release 15.1X49-D70 and in Junos OS Release 17.3R1, the set chassis routing-engine bios uninterrupt command is introduced on SRX300, SRX320, SRX340, and SRX345 devices to disable user inputs at U-boot and boot loader stage

351

15.1X49-D120

Starting in Junos OS Release 15.1X49-D120, the set chassis routing-engine bios uninterrupt command can be used on SRX300, SRX320, SRX340, and SRX345, devices to disable user inputs at U-boot, boot loader and and Junos-Kernel boot stage

RELATED DOCUMENTATION Installing Software on SRX Series Devices | 233
Installing and Upgrading Firmware

IN THIS SECTION
Before You Begin Installing or Upgrading the Firmware | 351 Installing Firmware on the 5-Port 100-Gigabit DWDM OTN PIC (PTX-5-100G-WDM) | 354 Upgrading Firmware on the 5-Port 100-Gigabit DWDM OTN PIC (PTX-5-100G-WDM) | 355 Installing Firmware on the 100-Gigabit DWDM OTN MIC (MIC3-100G-DWDM) | 357 Upgrading Firmware on the 100-Gigabit DWDM OTN MIC (MIC3-100G-DWDM) | 358 Installing Firmware on ACX6360 Router | 360 Upgrading Firmware on the ACX6360 Router | 361

To get the optimal network performance, and to fix a vulnerability, you can upgrade the firmware on your device.
Before You Begin Installing or Upgrading the Firmware
Before you begin installing or upgrading the firmware on the MIC or PIC, complete the following steps: 1. Verify that a previous version of the firmware package is installed on the router by using the show
version command.

352
show version (MX240, MX480, MX960, MX2010, MX2020)
user@host> show version Hostname: mxHost Model: mx480 Junos: 15.1I20160816_2117_yyin JUNOS OS Kernel 64-bit (WITNESS) [20160723.102341_fbsd-builder_stable_10] JUNOS OS libs [20160723.102341_fbsd-builder_stable_10] JUNOS OS runtime [20160723.102341_fbsd-builder_stable_10] JUNOS OS time zone information [20160723.102341_fbsd-builder_stable_10] ... JUNOS jfirmware [20160628.005233_builder_release_151_f_throttle] JUNOS Online Documentation [20160812.205759_yyin_release_151_f_throttle] JUNOS FIPS mode utilities [20160816.211724_yyin_release_151_f_throttle] ....
show version (PTX3000 and PTX5000)
user@host> show version Hostname: ptxHost Model: ptx3000 Junos: 15.1F-20160720.0 JUNOS Base OS boot [15.1F-20160720.0] JUNOS Base OS Software Suite [15.1F-20160720.0] JUNOS platform Software Suite [15.1F-20160720.0] JUNOS Web Management [15.1F-20160720.0] JUNOS Runtime Software Suite [15.1F-20160720.0] JUNOS Online Documentation [15.1F-20160720.0] ... JUNOS jfirmware [20160628.005233_builder_release_151_f_throttle] JUNOS 64-bit Runtime Software Suite [15.1F-20160720.0] JUNOS Packet Forwarding Engine Simulation Package [15.1F-20160720.0] JUNOS Packet Forwarding Engine Support (M/T/EX Common) [15.1F-20160720.0] JUNOS Packet Forwarding Engine Support (T-Series) [15.1F-20160720.0] JUNOS Routing Software Suite [15.1F-20160720.0]
show version (ACX6360)
user@host> show version Hostname: YYY

353
Model: ACX6360-OR Junos: 18.3I20180430_1917_XXX JUNOS OS Kernel 64-bit (WITNESS) [20180413.173511_fbsd-builder_stable_11] JUNOS OS libs [20180413.173511_fbsd-builder_stable_11] JUNOS OS runtime [20180413.173511_fbsd-builder_stable_11] JUNOS OS time zone information [20180413.173511_fbsd-builder_stable_11] ... JUNOS jfirmware [20180430.191738_XXX_dev_common] JUNOS Online Documentation [20180430.191738_XXX_dev_common] ...
If the output of the show version command displays JUNOS jfirmware.. among the list of packages that are installed on the router, then a previous version of the firmware package is installed on the router. If the output of the show version command does not display JUNOS jfirmware.. among the list of packages that are installed on the router, the firmware package is not installed on the router. 2. If a previous version of the firmware package is installed on the router, delete the firmware package from the router by using the request system software delete command. If a previous version of the firmware package is not installed on the router, then proceed to install the firmware package. For information about how to install the firmware package, see "Installing Firmware on the 100-Gigabit DWDM OTN MIC (MIC3-100G-DWDM) " on page 357 or "Installing Firmware on the 5-Port 100Gigabit DWDM OTN PIC (PTX-5-100G-WDM) " on page 354. For information about how to install the firmware package on ACX6360 router, see "Installing Firmware on ACX6360 Router" on page 360.
user@host> request system software delete jfirmware /packages/db/jfirmware-x86-32-15.1F-20160625.0
3. To verify that the firmware package is removed from the router, use the show version command.
user@host> show version Hostname: mxHost Model: mx240 Junos: 15.1F6-S1.3 JUNOS OS Kernel 64-bit [20160724.331042_builder_stable_10] JUNOS OS libs [20160724.331042_builder_stable_10] JUNOS OS runtime [20160724.331042_builder_stable_10] JUNOS OS time zone information [20160724.331042_builder_stable_10] .... JUNOS IDP Services [20160812.205945_builder_junos_151_f6_s1] ....

354
JUNOS Packet Forwarding Engine Support (M/T Common) [20160812.205945_builder_junos_151_f6_s1] JUNOS Online Documentation [20160812.205945_builder_junos_151_f6_s1] JUNOS FIPS mode utilities [20160812.205945_builder_junos_151_f6_s1]
show version (ACX6360)
user@host> show version Hostname: YYY
Model: ACX6360-OR Junos: 18.3I20180430_1917_XXX JUNOS OS Kernel 64-bit (WITNESS) [20180413.173511_fbsd-builder_stable_11] JUNOS OS libs [20180413.173511_fbsd-builder_stable_11] JUNOS OS runtime [20180413.173511_fbsd-builder_stable_11] JUNOS OS time zone information [20180413.173511_fbsd-builder_stable_11] ...
JUNOS IDP Services [20180430.191738_XXX_dev_common] ... JUNOS Online Documentation [20180430.191738_XXX_dev_common] ...
If the firmware package is uninstalled successfully, the output of the show version command does not display JUNOS jfirmware.. among the list of packages that are installed on the router.
Installing Firmware on the 5-Port 100-Gigabit DWDM OTN PIC (PTX-5-100G-WDM)
Before you install the firmware package, ensure that a previous version is not installed on the router. For more information, see "Before You Begin Installing or Upgrading the Firmware" on page 351. To install the firmware package, complete the following steps: 1. Upgrade Junos OS on the router to the version that supports the firmware package. See "Installing
the Software Package on a Device with Redundant Routing Engines" or "Installing the Software Package on a Router with a Single Routing Engine" on page 121 for more information. 2. Download the firmware package from https://support.juniper.net/support/downloads/. For information about downloading software packages, see "Downloading Software" on page 107.

355

NOTE: Download the firmware package specific to your router. The firmware package for PTX Series routers is different from the firmware package for the MX Series routers.
3. Save the firmware package to the /var/path/package-name directory on the router. For example, you can save the firmware package to the /var/tmp directory.
4. Install the firmware package by using the request system software add path/package-name command. For example, to install the jfirmware-15.1F6.9.tgz package:
user@host> request system software add jfirmware-15.1F6.9.tgz 5. Run the show version command to verify that the firmware package is installed.
user@host> show version
After the firmware package is installed successfully, the output of the show version command displays Junos jfirmware.. among the list of packages that are installed on the router.

Upgrading Firmware on the 5-Port 100-Gigabit DWDM OTN PIC (PTX-5-100G-WDM)
Before you upgrade the firmware package, ensure that a previous version is not installed on the router. For more information, see "Before You Begin Installing or Upgrading the Firmware" on page 351.
To upgrade the version of your firmware, complete the following steps:
1. Run the show system firmware command to view the list of components installed on the router and the firmware version for each component.

user@host> show system firmware

Part

Type

Tag Current

version version

FPC 0

ROM Monitor 0 0 10.4.1

FPC 1

ROM Monitor 0 0 10.4.1

FPC 2

ROM Monitor 0 0 10.4.1

PIC 0

CMIC LTC 2/0 1 .0

FPC 3

ROM Monitor 0 0 10.4.1

FPC 4

ROM Monitor 0 0 13.3.1

Available Status

OK

OK

OK

1.0

OK

OK

OK

356

FPC 4

MPCS(0)

2 0.24.0

OK

Routing Engine 0 RE BIOS

0 1.18

OK

Routing Engine 1

0 1.18

OK

The output of the show system firmware command displays the current firmware version of the PIC as .0 and the available firmware version as 1.0.
2. To upgrade the firmware of the PIC, use the request system firmware upgrade pic command. For example, to upgrade the firmware version of the PIC from .0 to 1.0, specify the FPC slot and PIC slot in the command.

user@host> request system firmware upgrade pic pic-slot 0 fpc-slot 2

Part

Type

Tag Current Available Status

version version

FPC 2

PIC 0

CMIC LTC 2/0 1 .0

1.0

OK

Perform indicated firmware upgrade ? [yes,no] (no) yes

Confirm that you want to perform the firmware upgrade by typing Yes so the firmware upgrade is initiated.
3. To monitor the progress of the upgrade, use the show system firmware command. During the installation process, the status of the PIC changes to PROGRAMMING. When the installation process is complete, the status of the PIC changes to UPGRADED SUCCESSFULLY.

NOTE: The amount of time it takes to upgrade firmware varies depending on the component.

user@host> show system firmware

Part

Type

Tag Current Available Status

version version

FPC 0

ROM Monitor 0 0 10.4.1

OK

FPC 1

ROM Monitor 0 0 10.4.1

OK

FPC 2

ROM Monitor 0 0 10.4.1

OK

PIC 0

CMIC LTC 2/0 1 1.0

1.0

UPGRADED SUCCESSFULLY

FPC 3

ROM Monitor 0 0 10.4.1

OK

FPC 4

ROM Monitor 0 0 13.3.1

OK

FPC 4

MPCS(0)

2 0.24.0

OK

Routing Engine 0 RE BIOS

0 1.18

OK

Routing Engine 1

0 1.18

OK

357
NOTE: If the installation process fails, delete the firmware package by using the request system software delete firmware-package-name command. Reinstall the firmware package by following the procedure for installing the firmware package and then upgrade the firmware package.
4. Restart the FPC that the PIC is installed in by using the request chassis fpc fpc-slot restart command. 5. (Optional) After the firmware upgrade is successfully completed, uninstall the firmware package from
the router by using the request system software delete command.
Installing Firmware on the 100-Gigabit DWDM OTN MIC (MIC3-100GDWDM)
Before you install the firmware package, ensure that a previous version is not installed on the router. For more information, see "Before You Begin Installing or Upgrading the Firmware" on page 351. To install the firmware package, complete the following steps: 1. Upgrade Junos OS on the router to the version that supports the firmware package. See "Installing
the Software Package on a Device with Redundant Routing Engines" or "Installing the Software Package on a Router with a Single Routing Engine" on page 121 for more information. 2. Download the firmware package from https://support.juniper.net/support/downloads/. For information about downloading software packages, see "Downloading Software" on page 107.
NOTE: Download the firmware package specific to your router. The firmware package for MX Series routers is different from the firmware package for the PTX Series routers.
3. Save the firmware package to the /var/path/package-name directory on the router. For example, you can save the firmware package to the /var/tmp directory.
4. Install the firmware package by using the request system software add /var/path/package-name command. For example, to install the jfirmware-x86-32-15.1F6.9.tgz package:
user@host> request system software add jfirmware-x86-32-15.1F6.9.tgz
5. Run the show version command to verify that the firmware package is installed.
user@host> show version Hostname: Host1

358
Model: mx480 Junos: 15.1I20160816_2117_yyin JUNOS OS Kernel 64-bit (WITNESS) [20160723.102341_fbsd-builder_stable_10] JUNOS OS libs [20160723.102341_fbsd-builder_stable_10] JUNOS OS runtime [20160723.102341_fbsd-builder_stable_10] JUNOS OS time zone information [20160723.102341_fbsd-builder_stable_10] ... JUNOS jfirmware [20160628.005233_builder_release_151_f_throttle] JUNOS Online Documentation [20160812.205759_yyin_release_151_f_throttle] JUNOS FIPS mode utilities [20160816.211724_yyin_release_151_f_throttle] ....
After the firmware package is installed successfully, the output of the show version command displays JUNOS jfirmware.. among the list of packages that are installed on the router.

Upgrading Firmware on the 100-Gigabit DWDM OTN MIC (MIC3-100GDWDM)
Before you upgrade the firmware package, ensure that a previous version is not installed on the router. For more information, see "Before You Begin Installing or Upgrading the Firmware" on page 351.
To upgrade the version of your firmware package, complete the following steps:
1. Run the show system firmware command to view the list of components installed on the router and the firmware version for each component.

user@host> show system firmware

Part

Type

Tag Current Available Status

version version

FPC 0

ROM Monitor 0 0 10.4.1

OK

FPC 1

ROM Monitor 0 0 10.4.1

OK

FPC 2

ROM Monitor 0 0 10.4.1

OK

PIC 0

CMIC LTC 2/0 1 .0

1.0

OK

FPC 3

ROM Monitor 0 0 10.4.1

OK

FPC 4

ROM Monitor 0 0 13.3.1

OK

FPC 4

MPCS(0)

2 0.24.0

OK

Routing Engine 0 RE BIOS

0 1.18

OK

Routing Engine 1

0 1.18

OK

359

The output of the show system firmware command displays the current firmware version of the MIC as .0 and the available firmware version as 1.0.
2. To upgrade the firmware of the MIC, use the request system firmware upgrade pic command. For example, to upgrade the firmware version of the MIC from .0 to 1.0, specify the MPC slot and MIC slot in the command.

user@host> request system firmware upgrade pic pic-slot 0 fpc-slot 2

Part

Type

Tag Current Available Status

version version

FPC 2

PIC 0

CMIC LTC 2/0

1 .0

1.0

OK

Perform indicated firmware upgrade ? [yes,no] (no) yes

Confirm that you want to perform the firmware upgrade by typing Yes so the firmware upgrade is initiated.
3. To monitor the progress of the upgrade, use the show system firmware command. During the installation process, the status of the MIC changes to PROGRAMMING. When the installation process is complete, the status of the MIC changes to UPGRADED SUCCESSFULLY.

NOTE: The amount of time it takes to upgrade firmware varies depending on the component.

user@host> show system firmware

Part

Type

Tag Current Available Status

version version

FPC 0

ROM Monitor 0 0 10.4.1

OK

FPC 1

ROM Monitor 0 0 10.4.1

OK

FPC 2

ROM Monitor 0 0 10.4.1

OK

PIC 0

CMIC LTC 2/0 1 .0

1.0

OK

FPC 3

ROM Monitor 0 0 10.4.1

OK

FPC 4

ROM Monitor 0 0 13.3.1

OK

FPC 4

MPCS(0)

2 0.24.0

OK

Routing Engine 0 RE BIOS

0 1.18

OK

Routing Engine 1

0 1.18

OK

360
NOTE: If the installation process fails, delete the firmware package by using the request system software delete firmware-package-name command. Reinstall the firmware package by following the procedure for installing the firmware package and then upgrade the firmware package.
4. Restart the MPC that the MIC is installed in by using the request chassis fpc fpc-slot restart command.
5. (Optional) After the firmware upgrade is successfully completed, uninstall the firmware package from the router by using the request system software delete command.
Installing Firmware on ACX6360 Router
Before you install the firmware package, ensure that a previous version is not installed on the router. For more information, see "Before You Begin Installing or Upgrading the Firmware" on page 351. To install the firmware package, complete the following steps: 1. Upgrade Junos OS on the router to the version that supports the firmware package. See "Installing
the Software Package on a Device with Redundant Routing Engines" or "Installing the Software Package on a Router with a Single Routing Engine" on page 121 for more information. 2. Download the firmware package from https://support.juniper.net/support/downloads/. For information about downloading software packages, see "Downloading Software" on page 107.
NOTE: Download the firmware package specific to your router. The firmware package for ACX Series routers is different from the firmware package for the MX or PTX Series routers.
3. Save the firmware package to the /var/path/package-name directory on the router. For example, you can save the firmware package to the /var/tmp directory.
4. Install the firmware package by using the request system software add /var/path/package-name command. For example, to install the jfirmware-x86-32-15.1F6.9.tgz package:
user@host> request system software add jfirmware-x86-32-15.1F6.9.tgz
5. Run the show version command to verify that the firmware package is installed.
user@host> show version Hostname: YYY

361

Model: ACX6360-OR Junos: 18.3I20180430_1917_XXX JUNOS OS Kernel 64-bit (WITNESS) [20180413.173511_fbsd-builder_stable_11] JUNOS OS libs [20180413.173511_fbsd-builder_stable_11] JUNOS OS runtime [20180413.173511_fbsd-builder_stable_11] JUNOS OS time zone information [20180413.173511_fbsd-builder_stable_11] ... JUNOS jfirmware [20180430.191738_XXX_dev_common] JUNOS Online Documentation [20180430.191738_XXX_dev_common] JUNOS jail runtime [20180413.173511_fbsd-builder_stable_11] ....
After the firmware package is installed successfully, the output of the show version command displays JUNOS jfirmware.. among the list of packages that are installed on the router.

Upgrading Firmware on the ACX6360 Router
Before you upgrade the firmware package, ensure that a previous version is not installed on the router. For more information, see "Before You Begin Installing or Upgrading the Firmware" on page 351. To upgrade the version of your firmware package, complete the following steps: 1. Run the show system firmware command to view the list of components installed on the router and
the firmware version for each component.

user@host> show system firmware

Part
Pseudo CB 0 Pseudo CB 0 Pseudo CB 0 FPC 0 PIC 1 PIC 1 PIC 1 PIC 1 PIC 1 PIC 1 PIC 1

Type
CB FPGA PORT FPGA TIC FPGA
DWDM DCO-0/1/0 DWDM DCO-0/1/1 DWDM DCO-0/1/2 DWDM DCO-0/1/3 DWDM DCO-0/1/4 DWDM DCO-0/1/5 DWDM DCO-0/1/6

Tag Current version
0 2.12.0 9 1.14.0 11 4101.5.0 0 0.0.0 20 38.1.9 21 1.0.0 22 1.0.0 23 1.0.0 24 1.0.0 25 1.0.0 26 1.0.0

Available Status version 2.12.0 OK 1.15.0 OK 4101.5.0 OK 71.63d OK 38.2.6 OK 38.2.6 OK 38.2.6 OK 38.2.6 OK 38.2.6 OK 38.2.6 OK 38.2.6 OK

362

PIC 1

DWDM DCO-0/1/7

Routing Engine 0 RE BIOS

Routing Engine 0 RE FPGA

Routing Engine 0 RE SSD1

Routing Engine 0 RE SSD2

Power Supply 0

Power Supply 1

27 1.0.0 7 0.24.1 2 9.6.0 3 12028 4 12028 0 0.0.0 0 0.0.0

38.2.6 OK

0.24.01 OK

9.9.0

OK

OK

OK

OK

OK

The output of the show system firmware command displays the current firmware version of the PIC as .0 and the available firmware version as 1.0.
2. To upgrade the firmware of the PIC, for ACX6360 use the request system firmware upgrade pic command. For example, to upgrade the firmware version of the PIC from .0 to 1.0, specify the FPC slot and PIC slot in the command.

user@host> request system firmware upgrade pic fpc-slot 0 pic-slot 1

Part

Type

Tag Current Available Status

version version

FPC 0

PIC 1

DWDM DCO-0/1/0 20 38.2.9 38.2.6 OK

Perform indicated firmware upgrade ? [yes,no] (no)

Confirm that you want to perform the firmware upgrade by typing Yes so the firmware upgrade is initiated.
3. To monitor the progress of the upgrade, use the show system firmware command. During the installation process, the status of the PIC changes to PROGRAMMING. When the installation process is complete, the status of the PIC changes to UPGRADED SUCCESSFULLY.

NOTE: The amount of time it takes to upgrade firmware varies depending on the component.

user@host> show system firmware

Part
Pseudo CB 0 Pseudo CB 0 Pseudo CB 0 FPC 0 PIC 1

Type
CB FPGA PORT FPGA TIC FPGA
DWDM DCO-0/1/0

Tag Current version
0 2.12.0 9 1.14.0 11 4101.5.0 0 0.0.0 20 38.2.6

Available Status version 2.12.0 OK 1.15.0 OK 4101.5.0 OK 71.63d OK 38.2.6 OK

363

PIC 1

DWDM DCO-0/1/1

PIC 1

DWDM DCO-0/1/2

PIC 1

DWDM DCO-0/1/3

PIC 1

DWDM DCO-0/1/4

PIC 1

DWDM DCO-0/1/5

PIC 1

DWDM DCO-0/1/6

PIC 1

DWDM DCO-0/1/7

Routing Engine 0 RE BIOS

Routing Engine 0 RE FPGA

Routing Engine 0 RE SSD1

Routing Engine 0 RE SSD2

Power Supply 0

Power Supply 1

21 1.0.0 22 1.0.0 23 1.0.0 24 1.0.0 25 1.0.0 26 1.0.0 27 1.0.0 7 0.24.1 2 9.6.0 3 12028 4 12028 0 0.0.0 0 0.0.0

38.2.6 OK

38.2.6 OK

38.2.6 OK

38.2.6 OK

38.2.6 OK

38.2.6 OK

38.2.6 OK

0.24.01 OK

9.9.0

OK

OK

OK

OK

OK

NOTE: If the installation process fails, delete the firmware package by using the request system software delete firmware-package-name command. Reinstall the firmware package by following the procedure for installing the firmware package and then upgrade the firmware package.
4. Restart the ACX6360 router by using request chassis fpc restart slot 0 command for the upgrade to take effect.
5. (Optional) After the firmware upgrade is successfully completed, uninstall the firmware package from the router by using the request system software delete command.

RELATED DOCUMENTATION
show system firmware Understanding the MIC3-100G-DWDM MIC Configuring OTN Interfaces on MIC3-100G-DWDM MIC Understanding the PTX-5-100G-WDM PIC Configuring OTN Interfaces on PTX-5-100G-WDM PIC

6 CHAPTER
Configuring Root Partitions
Configuring Dual-Root Partitions | 365 Configuring Root Partitions on SRX Series Devices | 369 Configuring Root Partitions on ACX Series Routers | 377

365
Configuring Dual-Root Partitions
IN THIS SECTION Resilient Dual-Root Partition Scheme (Junos OS Release 10.4R3 and Later) | 365 Automatic Fixing of Corrupted Primary Root Partition with the Automatic Snapshot Feature | 366 Earlier Partition Scheme (Junos OS Release 10.4R2 and Earlier) | 368 Understanding Upgrading or Downgrading Between Resilient Dual-Root Partition Releases and Earlier Releases | 368
Resilient dual-root partitioning, introduced on Juniper Networks EX Series Ethernet Switches in Juniper Networks Junos operating system (Junos OS) Release 10.4R3, provides additional resiliency to switches in the following ways: · Allows the switch to boot transparently from the second (alternate) root partition if the system fails
to boot from the primary root partition. · Provides separation of the root Junos OS file system from the /var file system. If corruption occurs in
the /var file system (a higher probability than in the root file system because of the greater frequency of reads and writes in /var), the root file system is insulated from the corruption.
NOTE: For instructions on upgrading to a release that supports resilient dual-root partitions from a release that does not, see the release notes. The procedure for upgrading to a resilient dualroot partition release is different from the normal upgrade procedure.
Resilient Dual-Root Partition Scheme (Junos OS Release 10.4R3 and Later)
EX Series switches that ship with Junos OS Release 10.4R3 or later are configured with a root partition scheme that is optimized for resiliency, as shown in Table 18 on page 366.

Table 18: Resilient Dual-Root Partition Scheme

Slice 1

Slice 2

Slice 3

366 Slice 4

s1a

s2a

s3e

/

/

/var

(root Junos OS ) (root Junos OS )

s3d /var/tmp

s4d /config

In the resilient dual-root partition scheme, the /var file system is contained in a separate slice (Slice 3) from the root file systems, the /config directory is contained in its own slice (Slice 4), and switches ship from the factory with identical Junos OS images in Slice 1 and Slice 2. The /var file system, which has a greater frequency of reads and writes than the root file systems and is therefore more likely to have corruption issues, is isolated from the root directories and the /config directory. If the switch fails to boot from the active partition, the switch automatically boots from the alternate root partition and triggers an alarm.

Automatic Fixing of Corrupted Primary Root Partition with the Automatic Snapshot Feature
Resilient dual-root partitioning also provides the automatic snapshot feature, which allows the switch to automatically fix a corrupt Junos OS file in the primary root partition. If the automatic snapshot feature is enabled, the switch automatically takes a snapshot of the Junos OS root file system in the alternate root partition and copies it onto the primary root partition, thereby repairing the corrupt file in the primary root partition. The automatic snapshot procedure takes place whenever the system reboots from the alternate root partition, regardless of whether the reboot is due to a command or due to corruption of the primary root partition.
NOTE: · EX9200 switches do not support the automatic snapshot feature.
· The automatic snapshot feature is enabled by default on the following EX Series switches:

367
· EX4550 switches
· EX Series switches that ship with Junos OS Release 12.3R1 or later
· The automatic snapshot feature is disabled by default on EX Series switches (except the EX4550 switches) running Junos OS Release 12.2 or earlier.
· If the automatic snapshot feature was disabled by default before the switch was upgraded to Junos OS Release 12.3R1 or later, the feature remains disabled (for backward compatibility) by default after the upgrade.
· If the automatic snapshot feature is enabled in a Virtual Chassis configuration, the automatic snapshot procedure takes place whenever any member of the Virtual Chassis reboots from its alternate root partition.
· You can enable the automatic snapshot feature by configuring the auto-snapshot statement at the [edit system] hierarchy level.
The automatic snapshot feature provides an additional layer of fault protection if you maintain the same version of Junos OS in both partitions of resilient dual-root partitions. When auto-snapshot is enabled, repair happens automatically. Therefore, the switch does not issue an alarm to indicate that the system has rebooted from the alternate partition. However, it does log the event. You cannot execute a manual snapshot when an automatic snapshot procedure is in process. The login banner indicates that an automatic snapshot operation is in progress and that banner is removed only after the snapshot operation is complete. The next reboot happens from the primary partition.
NOTE: EX Series switches that ship with Junos OS Release 10.4R3 or later are configured with identical Junos OS images in the primary root partition (Slice 1) and the alternate root partition (Slice 2). However, if you do not maintain the same version of Junos OS in both partitions, you might want to disable the automatic snapshot feature. If you have an earlier version of Junos OS in the alternate partition and the system reboots from the alternate root partition, the automatic snapshot feature causes the later Junos OS version to be replaced with the earlier version.
When automatic snapshot is disabled and the system reboots from the alternate root partition, it triggers an alarm indicating that the system has rebooted from its alternate partition.

368

Earlier Partition Scheme (Junos OS Release 10.4R2 and Earlier)

The partition scheme used in Junos OS 10.4R2 and earlier is shown in Table 19 on page 368. Table 19: Earlier Partition Scheme

Slice 1

Slice 2

Slice 3

s1a

s1f

/

/var

(root Junos OS)

s2a

s2f

s3d

(empty until initial software upgrade)

(empty until initial software upgrade)

/var/tmp

s3e /config

This is the partitioning scheme for a switch shipped with Release 10.4R2 or earlier (or after you reformat the disk during a downgrade from Release 10.4R3 or later to Release 10.4R2 or earlier). In this partitioning scheme, the switch comes from the factory with only one Junos OS image installed in the root Junos OS partition of Slice 1. The first time that you perform a software upgrade, the new Junos OS image is installed in Slice 2. If the switch fails to boot, you must manually trigger it to boot from the alternate partition (rebooting from the alternate partition does not occur automatically).

Understanding Upgrading or Downgrading Between Resilient Dual-Root Partition Releases and Earlier Releases
Upgrading from Release 10.4R2 or earlier to Release 10.4R3 or later differs from other upgrades in two important ways: · You must install a new loader software package in addition to installing the new Junos OS image.
· Rebooting after the upgrade reformats the disk from three partitions to four partitions. See Table 18 on page 366.
You can perform all operations for this special software upgrade from the CLI.

369
CAUTION: Back up any important log files because the /var/log files are not saved or restored during an upgrade from Release 10.4R2 or earlier to a release that supports resilient dual-root partitions (Release 10.4R3 or later). We recommend that you also save your /config files and any important log files to an external medium because if there is a power interruption during the upgrade process, they might be lost.
RELATED DOCUMENTATION auto-snapshot | 540
Configuring Root Partitions on SRX Series Devices
IN THIS SECTION Dual-Root Partitioning Scheme on SRX Series Devices | 369 Reinstalling the Single-Root Partition on SRX Series Devices | 376
The dual-root partitions help your SRX Series devices to remain functional even if the file system is corrupted. Also, it helps to recover the file system in case of corruption.
Dual-Root Partitioning Scheme on SRX Series Devices
IN THIS SECTION Boot Media and Boot Partition on SRX Series Devices | 370 Important Features of the Dual-Root Partitioning Scheme | 372 Understanding Automatic Recovery of the Primary Junos OS Image with Dual-Root Partitioning | 372

370
Understanding How the Primary Junos OS Image with Dual-Root Partitioning Recovers Devices | 374 Understanding How Junos OS Release 10.0 or Later Upgrades with Dual-Root Partitioning | 375
Junos OS Release 10.0 and later support dual-root partitioning on SRX Series devices. Dual-root partitioning allows the SRX Series device to remain functional even if there is file system corruption and to facilitate easy recovery of the file system.
NOTE: Starting in Junos OS Release 12.1X45, single root partitioning is not supported on SRX Series devices.
SRX Series devices running Junos OS Release 9.6 or earlier support a single-root partitioning scheme where there is only one root partition. Because both the primary and backup Junos OS images are located on the same root partition, the system fails to boot if there is corruption in the root file system. The dual-root partitioning scheme guards against this scenario by keeping the primary and backup Junos OS images in two independently bootable root partitions. If the primary root partition becomes corrupted, the system can still boot from the backup Junos OS image located in the other root partition and remain fully functional. SRX Series devices that ship with Junos OS Release 10.0 or later are formatted with dual-root partitions from the factory. SRX Series devices that are running Junos OS Release 9.6 or earlier can be formatted with dual-root partitions when they are upgraded to Junos OS Release 10.0 or later.
NOTE: Although you can install Junos OS Release 10.0 or later on SRX Series devices with the single-root partitioning scheme, we strongly recommend the use of the dual-root partitioning scheme.
Boot Media and Boot Partition on SRX Series Devices
When the SRX Series device powers on, it tries to boot the Junos OS from the default storage media. If the device fails to boot from the default storage media, it tries to boot from the alternate storage media. Table 20 on page 371 provides information on the storage media available on SRX Series devices.

371

Table 20: Storage Media on SRX Series Devices

SRX Series Devices

Storage Media

SRX100, SRX210, and SRX240

· Internal NAND flash (default; always present) · USB storage device (alternate)

SRX110, SRX220

· CompactFlash (default; always present) · USB storage device (alternate)

SRX300, SRX320, and SRX340, and SRX345

· eUSB disk (default; always present) · USB storage device (alternate)

SRX380

· Internal SSD (default, always present). · USB storage device (alternate)

SRX550

· Internal CF (default; always present) · USB storage device (alternate)

SRX550M

· Internal CF (default; always present) · USB storage device (alternate)

SRX650

· Internal CF (default; always present) · External flash card (alternate) · USB storage device (alternate)

With the dual-root partitioning scheme, the SRX Series device first tries to boot Junos OS from the primary root partition and then from the backup root partition on the default storage media. If both primary and backup root partitions of a media fail to boot, then the SRX Series device tries to boot from the next available type of storage media. The SRX Series device remains fully functional even if it boots Junos OS from the backup root partition of the storage media.

372

Important Features of the Dual-Root Partitioning Scheme
The dual-root partitioning scheme has the following important features:
· The primary and backup copies of Junos OS images reside in separate partitions. The partition containing the backup copy is mounted only when required. With the single-root partitioning scheme, there is one root partition that contains both the primary and the backup Junos OS images.
· The request system software add command for a Junos OS package erases the contents of the other root partition. The contents of the other root partition will not be valid unless software installation is completed successfully.
· Add-on packages, such as jais or jfirmware, can be reinstalled as required after a new Junos OS image is installed.
· The request system software rollback command does not delete the current Junos OS image. It is possible to switch back to the image by issuing the rollback command again.
· The request system software delete-backup and request system software validate commands do not take any action.
Understanding Automatic Recovery of the Primary Junos OS Image with Dual-Root Partitioning
The auto-snapshot feature repairs the corrupted primary root when the device reboots from the alternate root. This is accomplished by taking a snapshot of the alternate root onto the primary root automatically rather than manually from the CLI.
When this feature is enabled, and the device reboots from the alternate root (because of a corrupted primary root or power cycle during restart), the following actions take place:
1. A prominent message is displayed indicating a failure to boot from the primary root.

***********************************************************************

**

**

** WARNING: THIS DEVICE HAS BOOTED FROM THE BACKUP JUNOS IMAGE

**

**

**

** It is possible that the primary copy of JUNOS failed to boot up **

** properly, and so this device has booted from the backup copy. **

**

**

** Please re-install JUNOS to recover the primary copy in case

**

** it has been corrupted and if auto-snapshot feature is not

**

** enabled.

**

373

**

**

***********************************************************************

2. A system boot from backup root alarm is set. This is useful for devices that do not have console access.
3. A snapshot of the alternate root onto the primary root is made. 4. Once the snapshot is complete, the system boot from backup root alarm is cleared. During the next reboot, the system determines the good image on the primary root and boots normally.

NOTE: We recommend performing the snapshot once all the processes start. This is done to avoid any increase in the reboot time.

NOTE: · Auto-snapshot feature is supported on SRX300, SRX320, SRX340, SRX345, SRX380, and
SRX550M devices.
· By default the auto-snapshot feature is disabled.
· If you do not maintain the same version of Junos OS in both partitions, ensure that the automatic snapshot feature remains disabled. Otherwise, if you have an earlier version of Junos OS in the alternate partition and the system reboots from the alternate root partition, the automatic snapshot feature causes the later Junos OS version to be replaced with the earlier version.
· When automatic snapshot is disabled and the system reboots from the alternate root partition, it triggers an alarm indicating that the system has rebooted from its alternate partition.
Enable this feature with the set system auto-snapshot command. Once the primary root partition is recovered using this method, the device will successfully boot from the primary root partition on the next reboot.
Execute the delete system auto-snapshot command to delete all backed up data and disable autosnapshot, if required.
Use the show system auto-snapshot command to check the auto-snapshot status.

374
When auto-snapshot is in progress, you cannot run a manual snapshot command concurrently and the following error message appears:
Snapshot already in progress. Please try after sometime.
NOTE: If you log into the device when the snapshot is in progress, the following banner appears: The device has booted from the alternate partition, auto-snapshot is in progress.
Understanding How the Primary Junos OS Image with Dual-Root Partitioning Recovers Devices
If the SRX Series Services Gateway is unable to boot from the primary Junos OS image, and boots up from the backup Junos OS image in the backup root partition, a message appears on the console at the time of login indicating that the device has booted from the backup Junos OS image.

login: user

Password:

***********************************************************************

**

**

** WARNING: THIS DEVICE HAS BOOTED FROM THE BACKUP JUNOS IMAGE

**

**

**

** It is possible that the active copy of JUNOS failed to boot up **

** properly, and so this device has booted from the backup copy. **

**

**

** Please re-install JUNOS to recover the active copy in case

**

** it has been corrupted.

**

375

**

**

***********************************************************************

Because the system is left with only one functional root partition, you must immediately restore the primary Junos OS image using one of the following methods:
· Install a new image using the CLI or J-Web user interface. The newly installed image will become the primary image, and the device will boot from it on the next reboot.
· Use a snapshot of the backup root partition by entering the request system snapshot slice alternate command. Once the primary root partition is recovered using this method, the device will successfully boot from the primary root partition on the next reboot. After the procedure, the primary root partition will contain the same version of Junos OS as the backup root partition.
NOTE: You can use the CLI command request system snapshot slice alternate to back up the currently running root file system (primary or secondary) to the other root partition on the system along with following: · Save an image of the primary root partition in the backup root partition when system
boots from the primary root partition.
· Save an image of the backup root partition in the primary root partition when system boots from the backup root partition.

WARNING: The process of restoring the alternate root by using the CLI command request system snapshot slice alternate takes several minutes to complete. If you terminate the operation before completion, the alternate root might not have all required contents to function properly.
Understanding How Junos OS Release 10.0 or Later Upgrades with Dual-Root Partitioning
NOTE: If you are upgrading to Junos OS Release 10.0 without transitioning to dual-root partitioning, use the conventional CLI and J-Web user interface installation methods.

376
To format the media with dual-root partitioning while upgrading to Junos OS Release 10.0 or later, use one of the following installation methods: · Installation from the boot loader using a TFTP server. We recommend this if console access to the
system is available and a TFTP server is available in the network. See "Installing Junos OS on SRX Series Devices from the Boot Loader Using a TFTP Server" on page 252 · Installation from the boot loader using a USB storage device. We recommend this method if console access to the system is available and the system can be physically accessed to plug in a USB storage device. See "Installing Junos OS on SRX Series Devices from the Boot Loader Using a USB Storage Device" on page 255 · Installation from the CLI using the partition option. We recommend this method only if console access is not available. This installation can be performed remotely.
NOTE: After upgrading to Junos OS Release 10.0 or later, the U-boot and boot loader must be upgraded for the dual-root partitioning scheme to work properly.
Reinstalling the Single-Root Partition on SRX Series Devices
Junos OS Release 9.6 and earlier is not compatible with the dual-root partitioning scheme. These releases can only be installed if the media is reformatted with single-root partitioning. Any attempt to install Junos OS Release 9.6 or earlier on a device with dual-root partitioning without reformatting the media will fail with an error. You must install the Junos OS Release 9.6 or earlier image from the boot loader using a TFTP server or USB storage device.
NOTE: Junos OS Release 12.1X45 and later do not support single root partitioning.
NOTE: You do not need to reinstall the earlier version of the boot loader if you are installing Junos OS Release 9.6. You cannot install a Junos OS Release 9.6 or earlier package on a system with dual-root partitioning using the Junos OS CLI or J-Web. If this is attempted, an error will be returned. You can install the Junos OS Release 9.6 (9.6R3 and 9.6R4 [only]) on a system with dual-root partitioning using request system software add command with partition option.
To reinstall the single-root partition:

377

1. Enter the request system software add partition command to install the previous Junos OS version (9.6R3 and 9.6R4): user@host>request system software add partition
2. Reboot the device user@host>request system reboot
The previous software version gets installed after rebooting the device.

NOTE: Using the request system software add CLI command with the partition option to install Junos OS Release 9.6 (9.6R3 and 9.6R4) reformats the media with single-root partitioning. This process erases the dual-root partitioning scheme from the system, so the benefits of dual-root partitioning will no longer be available.

Release History Table

Release

Description

12.1X45-D10 Starting in Junos OS Release 12.1X45, single root partitioning is not supported on SRX Series devices.

RELATED DOCUMENTATION Installing Software on SRX Series Devices | 233
Configuring Root Partitions on ACX Series Routers

IN THIS SECTION
Dual-Root Partitioning ACX Series Routers Overview | 378 Understanding How the Primary Junos OS Image with Dual-Root Partitioning Recovers on the ACX Series Router | 379 Junos OS Release 12.2 or Later Upgrades with Dual-Root Partitioning on ACX Series Routers | 381 Example: Installing Junos OS and Configuring a Dual-Root Partition on ACX Series Routers Using the CLI | 382

378
The dual-root partitions help your ACX Series routers to remain functional even if the file system is corrupted. Also, it helps to recover the file system in case of corruption.
Dual-Root Partitioning ACX Series Routers Overview
IN THIS SECTION Boot Media and Boot Partition on the ACX Series Routers | 378 Important Features of the Dual-Root Partitioning Scheme | 379
Dual-root partitioning allows the ACX Series router to remain functional even if there is file system corruption and to facilitate easy recovery of the file system. Dual-root partitioning means that the primary and backup Junos OS images are kept in two independently bootable root partitions. If the primary root partition becomes corrupted, the system can still boot from the backup Junos OS image located in the other root partition and remain fully functional.
NOTE: ACX5048 and ACX5096 routers do not support dual-root partitioning. All other ACX routers run with dual-root partitioning.
Boot Media and Boot Partition on the ACX Series Routers
With dual-root partitioning, the ACX Series router first tries to boot the Junos OS from the primary root partition and then from the backup root partition on the internal NAND flash. If both primary and backup root partitions of the internal NAND flash fail to boot, you must insert a USB storage media with a copy of the Junos OS from which to boot. The following is the storage media available on the ACX Series router: · USB media emergency boot device
NOTE: The USB media device is not dual-root partitioned.
· Dual, internal NAND flash device (first daOs1, then daOs2)

379
Important Features of the Dual-Root Partitioning Scheme
The dual-root partitioning scheme has the following important features: · The primary and backup copies of Junos OS images reside in separate partitions. The partition
containing the backup copy is mounted only when required. With the single-root partitioning scheme, there is one root partition that contains both the primary and the backup Junos OS images. · The request system software add command for a Junos OS package erases the contents of the other root partition. The contents of the other root partition will not be valid unless software installation is completed successfully. · Add-on packages, such as jais or jfirmware, can be reinstalled as required after a new Junos OS image is installed. · The request system software rollback command does not delete the current Junos OS image. It is possible to switch back to the image by issuing the rollback command again.
Understanding How the Primary Junos OS Image with Dual-Root Partitioning Recovers on the ACX Series Router
If the ACX Series Universal Metro router is unable to boot from the primary Junos OS image and boots up from the backup Junos OS image in the backup root partition, a message appears on the console at the time of login indicating that the device has booted from the backup Junos OS image.
NOTE: ACX5048 and ACX5096 routers do not support dual-root partitioning.

login: user

Password:

***********************************************************************

**

**

** WARNING: THIS DEVICE HAS BOOTED FROM THE BACKUP JUNOS IMAGE

**

380

**

**

** It is possible that the active copy of JUNOS failed to boot up **

** properly, and so this device has booted from the backup copy. **

**

**

** Please re-install JUNOS to recover the active copy in case

**

** it has been corrupted.

**

**

**

***********************************************************************

Because the system is left with only one functional root partition, you should immediately restore the primary Junos OS image using one of the following methods:
· Install a new image using the CLI. When you install the new image, the new image is installed on only one partition­the alternate partition, meaning the router is now running two images. When you reboot, the router boots from the newly installed image, which becomes the primary image. So now there are two different images running on the router. Run the installation process again to update the other partition.
· Use a snapshot of the backup root partition by entering the request system snapshot slice alternate command. After the primary root partition is recovered using this method, the device will successfully boot from the primary root partition on the next reboot. After the procedure, the primary root partition will contain the same version of Junos OS as the backup root partition.
NOTE: You can use the CLI command request system snapshot slice alternate to back up the currently running root file system (primary or secondary) to the other root partition on the system. You can use this command to:
· Save an image of the primary root partition in the backup root partition when the system boots from the primary root partition.
· Save an image of the backup root partition in the primary root partition when the system boots from the backup root partition.

381
WARNING: The process of restoring the alternate root by using the CLI command request system snapshot slice alternate takes several minutes to complete. If you terminate the operation before completion, the alternate root might not have all required contents to function properly.
Junos OS Release 12.2 or Later Upgrades with Dual-Root Partitioning on ACX Series Routers
NOTE: If you are upgrading to Junos OS Release 12.2 without transitioning to dual-root partitioning, use the conventional CLI installation method.
To format the media with dual-root partitioning while upgrading to Junos OS Release 12.2 or later, use either of the following installation methods:
NOTE: ACX5048 and ACX5096 routers do not support dual-root partitioning. All other ACX routers run with dual-root partitioning.
· Installation using a USB storage device. We recommend this method if console access to the system is available and the system can be physically accessed to plug in a USB storage device. See Installing Junos OS Using a USB Storage Device on ACX Series Routers.
· Installation from the CLI. We recommend this method only if console access is not available. This installation can be performed remotely. See Installing Junos OS Upgrades from a Remote Server on ACX Series Routers.

382
Example: Installing Junos OS and Configuring a Dual-Root Partition on ACX Series Routers Using the CLI
IN THIS SECTION Requirements | 382 Overview | 382 Configuration | 383 Verification | 386
This example shows how to install Junos OS Release 12.2 or later and configure a dual-root partition on ACX Series routers with the CLI.
Requirements
This example requires an ACX Series router. Before you begin, back up any important data.
Overview
IN THIS SECTION Topology | 383
This example formats the NAND Flash device and installs the new Junos OS image on the media with dual-root partitioning. Install the Junos OS Release 12.2 or later image from the CLI by using the request system software add command. Partitions are automatically created on ACX Series routers and no option needs to be manually entered for creating partitions. This command copies the image to the device, and then reboots the device for installation. The device boots with the Release 12.2 or later image installed with the dual-root partitioning scheme. The formatting and installation process is scheduled to run on the next reboot. Therefore, we recommend that this option be used together with the reboot option.

383
NOTE: The process might take 15 to 20 minutes. The system is not accessible over the network during this time.
CAUTION: Using the request system software add command erases the existing contents of the media. Only the current configuration is preserved. You should back up any important data before starting the process.
NOTE: Dual, internal NAND Flash device (first daOs1, then daOs2) and USB storage device are the storage media available on the ACX Series router. The USB storage device is not dual-root partitioned.
In this example, add the software package junos-juniper-12.2R1.9-domestic.tgz with the following options: · no-copy option to install the software package. However, do not save the copies of the package files.
You should include this option if you do not have enough space on the internal media to perform an upgrade that keeps a copy of the package on the device. · no-validate option to bypass the compatibility check with the current configuration before installation starts. · reboot option to reboot the device after installation is completed.
Topology
Configuration
IN THIS SECTION Procedure | 384

384
Procedure
CLI Quick Configuration To install Junos OS Release 12.2 or later and configure dual-root partitioning on ACX Series routers, copy the following command, paste it in a text file, remove any line break, and then copy and paste the command into the CLI. From operational mode, enter:
user@host>request system software add junos-juniper-12.2R1.9-domestic.tgz no-copy no-validate reboot
Step-by-Step Procedure To install Junos OS Release 12.2 or later and configure a dual-root partition: 1. Upgrade the ACX Series router to Junos OS Release 12.2 or later using the CLI. 2. Install Junos OS Release 12.2 or later and configure the dual-root partition.
user@host>request system software add junos-juniper-12.2R1.9-domestic.tgz no-copy no-validate reboot Copying package junos-juniper-12.2R1.9-domestic.tgz to var/tmp/install Rebooting ...
Results In operational mode, confirm your configuration by entering the show system storage command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it. Sample output on a system with dual-root partitioning that displays information about the root partition that is mounted (only one root partition is mounted at a point in time):
user@host> show system storage

Filesystem /dev/da0s1a devfs

Size 872M 1.0K

Used 150M 1.0K

Avail 713M 0B

Capacity 17%
100%

Mounted on / /dev

385

/dev/md0

41M

41M

/dev/md1

183M

183M

jkernel-ppc-12.2I20121026_1217_sranjan

/dev/md2

30M

30M

ACX-12.2I20121026_1217_sranjan

/dev/md3

9.1M

9.1M

jdocs-12.2I20121026_1217_sranjan

/dev/md4

55M

55M

jroute-ppc-12.2I20121026_1217_sranjan

/dev/md5

12M

12M

jcrypto-ppc-12.2I20121026_1217_sranjan

/dev/md6

1.0G

8.0K

/dev/md7

1.0G

448K

/dev/da0s1e

92M

18K

procfs

4.0K

4.0K

/dev/da0s3f

3.9G

3.6G

/dev/da0s3d

447M

2.8M

0B 0B
0B
0B
0B
0B
951M 950M
91M 0B
30M 409M

100% /packages/mnt/jbase 100% /packages/mnt/

100% /packages/mnt/jpfe-

100% /packages/mnt/

100% /packages/mnt/

100% /packages/mnt/

0% 0% 0% 100% 99% 1%

/tmp /mfs /config /proc /var /var/log

If you are done configuring the device, enter commit in configuration mode.
You can issue the fdisk command from the Junos prompt to display information about the entire partition format on the NAND Flash device. All ACX Series routers run with dual-root partitioning. The following example displays the partition details on an ACX Series router with dual-root partitions:

user@host% fdisk

******* Working on device /dev/da0 ******* parameters extracted from in-core disklabel are: cylinders=487 heads=255 sectors/track=63 (16065 blks/cyl)
parameters to be used for BIOS calculations are: cylinders=487 heads=255 sectors/track=63 (16065 blks/cyl)
Media sector size is 512 Warning: BIOS sector numbering starts with sector 1 Information from DOS bootblock is: The data for partition 1 is: sysid 165 (0xa5),(FreeBSD/NetBSD/386BSD)
start 567, size 1011528 (493 Meg), flag 80 (active) beg: cyl 0/ head 9/ sector 1; end: cyl 62/ head 254/ sector 63

386
The data for partition 2 is: sysid 165 (0xa5),(FreeBSD/NetBSD/386BSD)
start 1012662, size 1011528 (493 Meg), flag 0 beg: cyl 63/ head 9/ sector 1; end: cyl 125/ head 254/ sector 63
The data for partition 3 is: sysid 165 (0xa5),(FreeBSD/NetBSD/386BSD)
start 2024757, size 3581928 (1748 Meg), flag 0 beg: cyl 126/ head 9/ sector 1; end: cyl 348/ head 254/ sector 63
The data for partition 4 is: sysid 165 (0xa5),(FreeBSD/NetBSD/386BSD)
start 5607252, size 2200338 (1074 Meg), flag 0 beg: cyl 349/ head 9/ sector 1; end: cyl 485/ head 254/ sector 63
In the preceding example, partition 1 and 2 contain two partitions each internally, a root partition and a configuration partition.
Verification
IN THIS SECTION Verifying the Partitioning Scheme Details | 386
Confirm that the configuration is working properly.
Verifying the Partitioning Scheme Details
Purpose
Verify that the partitioning scheme details on the ACX Series router were configured.
Action
In operational mode, enter the show system storage command. For details about the output of this command and the descriptions of the output fields, see show system storage.

387
RELATED DOCUMENTATION Installing Software on ACX Series Routers | 277

7 CHAPTER
Storage Media and Routing Engines
Storage Media and Routing Engines | 389

389
Storage Media and Routing Engines
IN THIS SECTION Routing Engines and Storage Media | 389 Repartitioning Routing Engine System Storage to Increase the Swap Partition | 390 System Memory and Storage Media on Routers | 391 Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, PTX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers) | 394 System Memory and Storage Media for SRX Series Services Gateways | 398 Accessing USB Storage on PTX1000 Routers | 403
Routing Engine and Packet Forwarding Engine (PFE) are the two primary components of Juniper Networks platforms. Junos OS software is installed on the routing engine and it is stored in storage media.
Routing Engines and Storage Media
Juniper Networks routing platforms are made up of two basic routing components: · Routing Engine--The Routing Engine controls the routing updates and system management. · Packet Forwarding Engine (PFE)--The Packet Forwarding Engine performs Layer 2 and Layer 3 packet
switching, route lookups, and packet forwarding. From a system administration perspective, you install the software onto the Routing Engine and during the installation, the appropriate software is forwarded to other components as necessary. Most Routing Engines include a CompactFlash card that stores Junos OS. On M Series Multiservice Edge Routers; MX240, MX480, and MX960 Universal Routing Platforms; T Series Core Routers; and TX Matrix routers, the system also includes a hard disk or solid-state drive (SSD) that acts as a backup boot drive. PTX Series Packet Transport Routers and the TX Matrix Plus router include a solid-state drive as a backup boot drive.

390
NOTE: The MX80 router is a single-board router with a built-in Routing Engine and single Packet Forwarding Engine. On an MX80 router, Junos OS is stored on dual, internal NAND flash devices. These devices provide the same functionality as a CompactFlash card and hard disk or solid-state drive (SSD).
NOTE: The ACX Series router is a single board router with a built-in Routing Engine and one Packet Forwarding Engine. The ACX router supports dual-root partitioning, which means that the primary and backup Junos OS images are kept in two independently bootable root partitions. If the primary partition becomes corrupted, the system remains fully functional by booting from the backup Junos OS image located in the other root partition.
On routing platforms with dual Routing Engines, each Routing Engine is independent with regard to upgrading the software. To install new software on both Routing Engines, you need to install the new software on each Routing Engine. On platforms with dual Routing Engines configured for high availability, you can use the unified in-service software upgrade procedure to upgrade the software. For more information about this procedure, see the High Availability User Guide for Routing Devices.
Repartitioning Routing Engine System Storage to Increase the Swap Partition
You can increase the size of the swap partition by repartitioning the drive (hard disk or solid-state drive [SSD]) on the Routing Engine. This feature is first available in Junos OS Release 10.4R5, 11.1R3, and 11.2R1; in earlier Junos OS releases, the swap partition is not increased by the methods described here. This behavior applies only to Routing Engines with more than 2 GB of RAM. The new size of the swap partition depends on the size of the drive and the amount of Routing Engine RAM. · When the drive is 32 GB or less, the swap partition is limited to 8 GB. · When the drive is larger than 32 GB, the swap partition matches the size of the Routing Engine RAM. To repartition the drive, perform one of the following actions: · During the installation of a Junos OS software package (jinstall*), issue the request system reboot
media disk command to boot from the drive instead of issuing the request system reboot command. The drive is automatically repartitioned. The request system reboot media disk command repartitions the drive only during a software upgrade.

391
· Manually partition the drive by issuing the request system partition hard-disk command, and then reboot the router when the command completes.
CAUTION: Repartitioning the drive re-creates the /config and /var directories in the router file system. Although the contents of /config and /var/db are preserved, the remaining contents of /var are lost. For this reason, we recommend that you back up the /var directory before you repartition the SSD on a router with this configuration.
System Memory and Storage Media on Routers
IN THIS SECTION System Memory | 392 Storage Media | 393

392 Figure 10 on page 392 shows examples of Routing Engines. Figure 10: Routing Engines
System Memory
Starting with Junos OS Release 9.0, all routing platforms require a minimum of 512 MB of system memory on each Routing Engine. All M7i and M10i routers delivered before December 7, 2007, had 256 MB of memory. These routers require a system memory upgrade before you install Junos OS Release 9.0

393
or a later release. To determine the amount of memory currently installed on your system, use the show chassis routing-engine command in the command-line interface (CLI).
For more information about upgrading your M7i or M10i router, see the Customer Support Center JTAC Technical Bulletin PSN-2007-10-001: https://www.juniper.net/alerts/viewalert.jsp? txtAlertNumber=PSN-2007-10-001&actionBtn=Search.
ACX2000 routers are shipped with 2 GB of memory and ACX1000 routers with 1 GB of memory.
Storage Media
Except for the ACX Series, MX80 routers, and MX104 routers, the M Series, MX Series, PTX Series, T Series, TX Matrix, and TX Matrix Plus routers use the following media storage devices:
· CompactFlash card--The CompactFlash card is typically the primary storage device for most routers.
NOTE: M7i and M10i routers using RE-400 are not delivered from the factory with the CompactFlash card installed. In this case, the hard disk is the primary and only boot device. The M7i and M10i routers with RE-400 can be upgraded to include the CompactFlash card.
· Hard disk or solid -state drive--For most routers, a hard disk or solid-state drive is the secondary boot device. When the CompactFlash card is not installed on the router, the hard disk or the solidstate drive becomes the primary boot device. The hard disk or solid-state drive is also used to store system log files and diagnostic dump files.
· Emergency boot device--Depending on the router, the emergency boot device can be a PC card, a USB storage device, or an LS-120 floppy disk.
On MX80 routers, the internal NAND flash devices (first da0, then da1) act as the primary and secondary boot devices.
On ACX Series routers, the internal NAND flash devices (first da0s1, then da0s2) act as the primary and secondary boot devices.
Emergency boot devices can be used to revive a routing platform that has a damaged Junos OS. When an emergency boot device is attached to the router, the router attempts to boot from that device before it boots from the CompactFlash card, solid-state drive (SSD), or hard disk.
On an ACX Series router, the emergency boot device is a USB storage device.
On MX104 routers, the internal NAND flash device (da0) mounted on the internal eUSB card acts as the primary boot and storage device. On MX104 routers, the emergency boot device is a USB storage device that is plugged into one of the USB ports in the front plate.

394
When booting from an emergency boot device, the router requests a boot acknowledgment on the console interface. If you enter yes, the emergency boot device repartitions the primary boot device and reloads Junos OS onto the primary boot device. After the loading is complete, the routing platform requests that you remove the emergency boot device and reboot the system. After the reboot is complete, you must perform an initial configuration of the router before it can be used on your network.
NOTE: For routers with RE-MX-X6, RE-MX-X8, and RE-PTX-X8 Routing Engines, a set of two 64-GB SSDs are available for storage and redundancy. For more information see Storage Partitioning and Redundancy topic in Salient Features of the Routing Engines with VM Host Support section.

Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, PTX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers)

Table 21 on page 394 specifies the storage media names by Routing Engine. The storage media device names are displayed when the router boots.
Table 21: Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers)

Routing Engine

Type of Junos CompactFlas Hard Disk

OS

h Card

Solid-State Drive

Removable Media Emergency Boot Device

RE-400-768 (RE5) FreeBSD 6.x ad0

ad1

No

ad3

RE-600-2048

FreeBSD 6.x ad0

ad1

No

ad3

(RE3)

RE-850-1536

FreeBSD 6.x ad0

ad1

No

ad3

(RE-850)

395

Table 21: Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers) (Continued)

Routing Engine

Type of Junos CompactFlas Hard Disk

OS

h Card

Solid-State Drive

Removable Media Emergency Boot Device

RE-A-1000-2048 FreeBSD 6.x ad0

ad2

No

da0

(RE-A-1000)

RE-A-1800x2 (RE- FreeBSD 6.x ad0

No

A-1800)

Yes

da0

SSD1: ad1

SSD2: ad2

RE-S-1300-2048 FreeBSD 6.x ad0

ad2

No

da0

(RE-S-1300)

RE-S-1800x2

FreeBSD 6.x ad0

No

RE-S-1800x4

(RE-S-1800)

FreeBSD 10.x/11.x

Yes

da0

SSD1: ad1

SSD2: ad2

RE-B-1800X1-4G- FreeBSD 6.x ad0

No

S

Yes

da0

SSD1: ad1

RE-1600-2048

FreeBSD 6.x ad0

ad1

No

(RE4)

ad3 and ad4

RE-A-2000-4096 FreeBSD 6.x ad0

ad2

No

da0

(RE-A-2000)

396

Table 21: Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers) (Continued)

Routing Engine

Type of Junos CompactFlas Hard Disk

OS

h Card

Solid-State Drive

Removable Media Emergency Boot Device

RE-S-2000-4096 FreeBSD 6.x ad0

ad2

No

da0

(RE-S-2000)

RE-MX-104

FreeBSD 6.x No

da0

No

da1 and da2

RE-DUO-

FreeBSD 6.x ad0

No

C2600-16G (RE-

DUO-2600)

ad1

da0

RE-DUO-

FreeBSD 6.x ad0

No

C1800-8G- (RE-

DUO-1800)

ad1

da0

RE-DUO-

FreeBSD 6.x ad0

No

C1800-16G

ad1

da0

RE-

FreeBSD 6.x da0

da1

No

da2

JCS1200-1x2330

RE-PTX-X8-64G FreeBSD 6.x No

No

Yes

da0

SSD1: sda

SSD2: sdb

RE-S-X6-64G

FreeBSD 6.x No

No

Yes

da0

SSD1: sda

SSD2: sdb

397

Table 21: Routing Engines and Storage Media Names (ACX Series, M Series, MX Series, T Series, TX Matrix, TX Matrix Plus, and JCS 1200 Routers) (Continued)

Routing Engine

Type of Junos CompactFlas Hard Disk

OS

h Card

Solid-State Drive

Removable Media Emergency Boot Device

REMX2K-X8-64G FreeBSD 6.x No

No

Yes

da0

SSD1: sda

SSD2: sdb

NOTE: On MX80 routers, the Routing Engine is a built-in device and has no model number. The dual internal NAND flash devices are da0 and da1. The USB storage device is da2.
NOTE: On ACX Series routers, the Routing Engine is a built-in device which does not have a model number. The dual internal NAND flash devices are da0s1 and da0s2. The USB storage device is da0s2a. Use the show chassis hardware models command to obtain the fieldreplaceable unit (FRU) model number--for example, ACX2000BASE-DC for the ACX2000 router.
To view the storage media currently available on your system, use the CLI show system storage command.
SEE ALSO Supported Routing Engines by Router Routing Engine Specifications RE-S-1300 Routing Engine Description RE-S-2000 Routing Engine Description RE-S-1800 Routing Engine Description JCS1200 Routing Engine Description

398
System Memory and Storage Media for SRX Series Services Gateways
IN THIS SECTION SRX Series Device Overview | 398 System Memory | 401 Storage Media | 401
SRX Series Device Overview
Figure 11 on page 398 shows an example of SRX240 device. Figure 11: SRX240 Device Front Panel

399 Figure 12 on page 399 shows an example of SRX650 device. Figure 12: SRX650 Device System Routing Engine
Figure 13 on page 399 shows the front panel of an SRX345 device. Figure 13: SRX345 Device Front Panel Figure 14 on page 399 shows an example of an SRX1500 device. Figure 14: SRX1500 Device Front Panel

400 Figure 15 on page 400 shows an example of an SRX4200 device. Figure 15: SRX4200 Services Gateway Front Panel
Figure 16 on page 400 shows an example of an SRX4600 device. Figure 16: SRX4600 Services Gateway Front Panel
Figure 17 on page 400 shows an example of an SRX5800 device Routing Engine. Figure 17: SRX5800 Device Routing Engine

401
System Memory
The amount of free disk space necessary to upgrade a device with a new version of Junos OS can vary from one release to another for different SRX Series devices. Check the Junos OS software version you are installing to determine the free disk space requirements. To determine the amount of free disk space on the device, issue the show system storage detail command. The command output displays statistics about the amount of free disk space in the device file systems.
Storage Media
The SRX100, SRX210, SRX240, Services Gateway can boot from the following storage media (in the order of priority): · Internal NAND Flash (default; always present) · USB storage key (alternate) The SRX550 and SRX650 Services Gateway can boot from the following storage media (in the order of priority): · CompactFlash (default; always present) · External CompactFlash card (alternate) (SRX650 only) · USB storage key (alternate) The SRX300, SRX320, SRX340, and SRX345 Services Gateway can boot from the following storage media (in the order of priority): · Internal NAND flash device mounted on the internal eUSB card (default; always present) · USB storage key (alternate) · External SSD (SRX340 and SRX345 devices) The SRX380 Services Gateway can boot from the following storage media (in the order of priority): · Internal SSD (default; always present) · USB storage key (alternate) The SRX550M Services Gateway can boot from the following storage media (in the order of priority): · CompactFlash (default; always present) · USB storage key (alternate)

402

· External SSD SRX1500 device use the following media storage devices: · Internal eSATA flash disk (default; always present) · SSD SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800 devices use the following media storage devices: · The CompactFlash card in the Routing Engine · The hard disk in the Routing Engine
NOTE: You can also use a Junos OS image stored on a USB flash drive that you insert into the Routing Engine faceplate.

The SRX4100 and SRX4200 devices include the following storage media: · Internal eSATA flash disk (default; always present) · SSD The SRX4600 devices include the following storage media: · Internal eSATA flash disk (default; always present) · SSD Table 22 on page 402 specifies the storage media names used by the SRX Series devices. The storage media device names are displayed as the device boots. Table 22: Storage Media Names

Device

Internal CompactFlash Card

USB Storage Media Devices

SRX Series device

da0

da1

To view the storage media currently available on your system, use the CLI show system storage command.

403
SEE ALSO Verifying PIC Combinations | 529
Accessing USB Storage on PTX1000 Routers
On PTX1000 routers, you can only view the USB storage information from Junos OS by using the CLI command "show vmhost hardware" on page 922, but cannot access it. However, you can access the USB storage information from the Linux host. From the Linux host, you can also send the USB storage device information with images across different sites where PTX1000 routers are deployed. To access the USB storage device information on PTX1000 routers: 1. In Junos OS, ensure that the PTX1000 USB image to be copied to the USB storage device is present
on the var/tmp folder of Junos OS. To copy the image from the /var/tmp directory of Junos OS to the /var/tmp directory of a Linux host, execute the following command on Junos OS: vhclient rcp /var/tmp image-name vhclient -s 2. On the Linux host shell, execute the following command:

dd if=/var/tmp/ copied-image-name of=/dev/sdc bs=4M sync sync
In the command above, /dev/sdc is the USB storage device detected by the Linux host. You can determine the name of the USB storage device from host logs as shown in the sample below:

user@host # dmesg

...

...

[645888.884431] usb 1-1.2: new high-speed USB device number 5 using ehci-pci

[645889.131217] usb-storage 1-1.2:1.0: USB Mass Storage device detected

[645889.131275] scsi8 : usb-storage 1-1.2:1.0

[645890.134290] scsi 8:0:0:0: Direct-Access

JetFlash Transcend 8GB

8.07 PQ: 0 ANSI: 2

[645890.134456] sd 8:0:0:0: Attached scsi generic sg2 type 0

404
[645890.135908] sd 8:0:0:0: [sdc] 15687680 512-byte logical blocks: (8.03 GB/ 7.48 GiB) In this example, sdc is the name of the USB storage device.
NOTE: The /var/tmp directory of a Linux host is mounted on the RAM (at the ramfs location), which is volatile storage, and is thus lost when you perform power cycling of or reboot the device. However, the Junos OS /var/tmp directory resides on the physical (nonvolatile) hard disk and thus exists even after rebooting or power cycling.
SEE ALSO Creating an Emergency Boot Device for Routers | 27
RELATED DOCUMENTATION Installing Software on Routing Devices | 121

8 CHAPTER
Zero Touch Provisioning
Zero Touch Provisioning | 406

406
Zero Touch Provisioning
IN THIS SECTION Zero Touch Provisioning Overview | 406 Zero Touch Provisioning Using DHCP Options | 414 Zero Touch Provisioning Using DHCPv6 Options | 422 Zero Touch Provisioning on SRX Series Devices | 429 Monitoring Zero Touch Provisioning | 438
Zero Touch Provisioning installs or upgrades the software automatically on your new Juniper Networks devices with minimal manual intervention.
Zero Touch Provisioning Overview
IN THIS SECTION ZTP Workflow | 409 Provisioning a Device Using a Script | 410 Zero Touch Provisioning Restart Process Triggers | 411 Caveats Relating to ZTP | 412 Zero Touch Provisioning Using WAN Interfaces on PTX1000 Routers | 413 Zero Touch Provisioning on PTX10008 Routers | 414
Zero Touch Provisioning (ZTP) allows you to provision new Juniper Networks devices in your network automatically, with minimal manual intervention. You can use either management ports or network ports, depending on your device, to connect to the network. When you physically connect a device to the network and boot it with a default factory configuration, the device upgrades (or downgrades) the Junos OS release and autoinstalls a configuration file from the network. The configuration file can be a Junos OS configuration or a script. Using scripts, you can create device-specific configuration files and

407
perform HTTP request operations to web servers to download specific configuration files or Junos OS releases.
To locate the necessary software image and configuration files on the network, the device uses information that you have configured on a Dynamic Host Configuration Protocol (DHCP) server. If you do not configure the DHCP server to provide this information, the device boots with the preinstalled software and default factory configuration.
Originally (as of Junos OS release 12.2), the only devices that supported ZTP (or EZ Touchless Provisioning as it was previously known) were EX Series switches and only configuration files could be used to provision configuration.
Over subsequent Junos OS releases, ZTP support has expanded:
· Starting in Junos OS Release 16.1R1, you can provision supported devices by using either a script to be executed or a configuration file to be loaded.
· Starting in Junos OS Release 17.2R1, ZTP can automate the provisioning of the device configuration and software image on VM host platforms that use PTX1000 routers.
· Starting in Junos OS Release 18.1R1, ZTP can automate the provisioning of the device configuration and software image on VM host platforms that use QFX10002-60C switches.
· Starting in Junos OS Release 18.2R1, ZTP can automate the provisioning of the device configuration and software image on VM host platforms that use PTX5000, PTX3000, PTX10008, PTX10016, PTX10002-60C routers.
· Starting in Junos OS Release 18.2R1, ZTP can automate the provisioning of the device configuration and software image on VM host platforms that use QFX10008 and QFX10016 switches.
· Starting in Junos OS Release 18.3R1, ZTP, which automates the provisioning of the device configuration and software image with minimal manual intervention, is supported on MX Series VM hosts.
· Starting in Junos OS Release 19.2R1, ZTP can automate the provisioning of the device configuration and software image on management interface emo for ACX5448 switches.
Starting in Junos OS Evolved Release 19.1R1, ZTP can automate the provisioning of the device configuration and software image on the management interface for QFX5220 and PTX10003 devices. The management interfaces for PTX10003 devices are re0:mgmt-0 and re0:mgmt-1. The management interface for QFX5220 devices is vmb0.
· Starting in Junos OS Release 19.4R1, ZTP can automate the provisioning of the device configuration and software image on Juniper Route Reflector (JRR). ZTP supports self image upgrades and automatic configuration updates using ZTP DHCP options. In this release, ZTP supports revenue ports em2 thru em9, in addition to management port em0 which is supported in Junos OS Releases before 19.4R1.

408
· Starting in Junos OS Evolved Release 20.1R1 on PTX10003 devices, Zero Touch Provisioning (ZTP) dynamically detects the port speed of WAN interfaces and uses this information to create ZTP server ports with the same speed.
· Starting in Junos OS Evolved Release 20.1R1, PTX10008 devices support automation of the device configuration and software upgrade over the management interface of Routing Engine 0 (RE0).
· Starting in Junos OS Release 20.2R1-S1 on the MX-Series, EX3400, EX4300, QFX5100, and QFX5200 devices, ZTP supports the DHCPv6 client. During the bootstrap process, the device first uses the DHCPv4 client to request for information regarding image and configuration file from the DHCP server. The device checks the DHCPv4 bindings sequentially. If there is a failure with one of the DHCPv4 bindings, the device will continue to check for bindings until provisioning is successful. If there are no DHCPv4 bindings, however, the device will check for DHCPv6 bindings and follow the same process as for DHCPv4 until the device can be provisioned successfully. The DHCP server uses DHCPv6 options 59 and 17 and applicable sub-options to exchange ZTP-related information between itself and the DHCP client.
· Starting in Junos OS Release 20.2R1 on SRX300, SRX320, SRX340, SRX345, SRX550 HM, and SRX1500 devices, you can use Zero Touch Provisioning with DHCP options or the phone-home client to provision your device.
· Starting in Junos OS Release 20.4R1 on the MX-Series, EX3400, EX4300, QFX5100, and QFX5200 devices, ZTP supports the DHCPv6 client. During the bootstrap process, the device first uses the DHCPv4 client to request for information regarding image and configuration file from the DHCP server. The device checks the DHCPv4 bindings sequentially. If there is a failure with one of the DHCPv4 bindings, the device will continue to check for bindings until provisioning is successful. If there are no DHCPv4 bindings, however, the device will check for DHCPv6 bindings and follow the same process as for DHCPv4 until the device can be provisioned successfully. The DHCP server uses DHCPv6 options 59 and 17 and applicable sub-options to exchange ZTP-related information between itself and the DHCP client.
· Starting in Junos OS Release 20.4R1 on the EX4600, EX4650, EX9200 with RE-S-EX9200-2X00X6, QFX5110, QFX5200, QFX5210, QFX5120-32C, and QFX5120-48Y devices, you can use either the legacy DHCP-options-based ZTP or the phone-home client (PHC) to provision software for the switch. When the switch boots up, if there are DHCP options that have been received from the DHCP server for ZTP, ZTP resumes. If DHCP options are not present, PHC is attempted. PHC enables the switch to securely obtain bootstrapping data, such as a configuration or software image, with no user intervention other than having to physically connect the switch to the network. When the switch first boots up, PHC connects to a redirect server, which redirects to a phone home server to obtain the configuration or software image. .
· Starting in Junos OS Evolved Release 20.4R1, PTX10004 devices support automation of the device configuration and software upgrade over the management interface of Routing Engine 0 (RE0).

409
· Starting in Junos OS Evolved Release 20.4R1, ACX5448 and QFX5120-48YM devices support the ability for either WAN interfaces or management interfaces to automatically download and install the appropriate software and the configuration file on your device during the ZTP bootstrap process.
· Starting in Junos OS Release 21.1R1, on EX2300, EX2300-VC, EX3400, EX3400-VC, EX4400-24T, EX4400-48F, EX4400-48T, and EX4600 devices, during the bootstrapping process, the phone-home client can access the redirect server through a proxy server. The DHCP server uses DHCP option 43 suboption 8 to deliver the details of IPv4 and/or IPv6 proxy servers to the phone-home client. The DHCP daemon running on the target switch learns about the proxy servers in the initial DHCP cycle and then populates either the phc_vendor_specific_info.xml or the phc_v6_vendor-specific_info.xml files located in the /var/etc/ directory with the vendor-specific information.
· Starting in Junos OS Release 21.1R1, on EX2300, EX2300-VC, EX3400, EX3400-VC, EX4400-24T, EX4400-48F, EX4400-48T, and EX4600 devices, when the phone-home client receives information regarding the HTTP proxy server via DHCP option 43 suboption 8, it will create an HTTPS transparent tunnel with the proxy server. Once the tunnel is established, the phone-home client uses the tunnel as a proxy for the phone-home server or redirect server. The phone-home client downloads the software image and configuration file through the tunnel onto the device. Once bootstrapping is complete, the device reboots and the tunnel quits.
NOTE: To see which platforms support ZTP, in a browser, go to Feature Explorer. In the Explore Features section of the Feature Explorer page, select All Features. In the Features Grouped by Feature Family box, select Zero Touch Provisioning. You can also type the name of the feature in the Search for Features edit box.
ZTP Workflow
When a device boots up with the default configuration, the following events take place:
1. DHCP client is enabled on supported interfaces.
2. DHCP server provisions an IP address and includes several DHCP options in the reply related to the ZTP process.
3. The device processes the DHCP options and locates configuration files, executes scripts, and upgrades and/or downgrades software.
4. If both the image and configuration files are present, the image is installed and the configuration is applied.
5. If only the image file is present, the image is installed on the device.

410
6. If the image is the same as the image already installed on the device, ZTP continues and skips the installation step.
7. If the image was unable to be fetched by the device, ZTP will try to fetch the image again.
8. If the image is corrupted, installation fails.
If installation fails for any reason, the ZTP will restart.
9. If only the configuration file is present, the configuration is downloaded.
If the first line of the file consists of the #! characters followed by an interpreter path, then the file is considered a script, and the script is executed by the interpreter. If the script returns an error, the ZTP state machine will refetch the script and attempt to execute the script again.
If the configuration file is unable to be downloaded, the ZTP process will try to download it again.
If the configuration file is corrupted, has syntax errors, or includes commands that are unsupported by the device, the device will be unable to commit, and the retry mechanism will restart.
10. If there is no image or configuration file, the ZTP process starts again.
11. If there is no file server information, the ZTP process starts again.
12. Once the configuration is committed, the ZTP process is deemed successful and terminates.
Provisioning a Device Using a Script
During the ZTP process, when you connect and boot a new networking device, the device requests an IP address from the DHCP server. The server provides the IP address, and if configured, the filenames and locations for the software image and configuration file for the device. The configuration file can be a Junos OS configuration or a script.
If a configuration file is provided, Junos OS determines if the file is a script based on the first line of the file. If the first line contains the characters #! followed by an interpreter path, Junos OS treats the file as a script and executes it with the specified interpreter. If the script returns an error (that is, a nonzero value), the ZTP state machine refetches the script and attempts to execute it again. This continues until the script executes successfully.
Table 23 on page 411 outlines the supported script types, the corresponding interpreter path, and the platforms that support that script type during the ZTP process.

411

Table 23: Scripts Supported During ZTP Script Type Interpreter Path

Platform Support

Shell script

#!/bin/sh

All devices

SLAX script #!/usr/libexec/ui/cscript All devices

Python script #!/usr/bin/python

Devices running Junos OS with Enhanced Automation Devices running Junos OS Evolved

NOTE: For security reasons, Junos OS has strict requirements for running unsigned Python scripts on devices running Junos OS. Only devices running Junos OS with Enhanced Automation and devices running Junos OS Evolved support using unsigned Python scripts in DHCP option 43 suboption 01.
If Junos OS does not find the characters #! followed by an interpreter path, it treats the file as a Junos OS configuration in text format and loads the configuration on the device.
Zero Touch Provisioning Restart Process Triggers
ZTP restarts when any of the following events occur: · Request for configuration file, script file, or image file fails. · Configuration file is incorrect, and commit fails. · No configuration file and no image file is available. · Image file is corrupted, and installation fails. · No file server information is available. · DHCP server does not have valid ZTP parameters configured. · When none of the DHCP client interfaces goes to a bound state. · ZTP transaction fails after six attempts to fetch configuration file or image file.

412
NOTE: On devices running Junos OS Evolved, if downloading a file fails, ZTP restarts.
When any of these events occur, ZTP resets the DHCP client state machine on all of the DHCP clientconfigured interfaces (management and network) and then restarts the state machine. Restarting the state machine enables the DHCP client to get the latest DHCP server-configured parameters. Before ZTP restarts, approximately 15 to 30 seconds must elapse to allow enough time to build a list of bound and unbound DHCP client interfaces. The list of bound and unbound DHCP client interfaces can contain: · No entries.
· Multiple DHCP client interfaces. Priority is given to the DHCP client interfaces that have received all ZTP parameters (software image file, configuration file, and file server information) from the DHCP server.
After the lists of bound and unbound client interfaces are created, and a DHCP client gets selected for ZTP activity, any existing default route is deleted and the DHCP client interface that was selected adds a new default route. In order to add a new default route, only one ZTP instance can be active. After ZTP restarts, the DHCP client attempts fetching files from the DHCP server for up to six times, with ten to fifteen seconds elapsing between attempts. Every attempt, whether successful or not, is logged and can be seen on the console. If there is a failure, or the number of attempts exceeds the limit, ZTP stops. ZTP then clears the DHCP client bindings and restarts state machine on the DHCP-configured interfaces. The ZTP restart process continues until there is either a successful software upgrade, or an operator manually commits a user configuration and deletes the ZTP configuration.
Caveats Relating to ZTP
There are two downgrade limitations for EX Series switches: · If you downgrade to a software version earlier than Junos OS Release 12.2, in which ZTP is not
supported, the configuration file autoinstall phase of the zero touch provisioning process does not happen.
· To downgrade to a software version that does not support resilient dual-root partitions (Junos OS Release 10.4R2 or earlier), you must perform some manual work on the device. For more information, see Configuring Dual-Root Partitions.
The following are caveats for QFX Series switches:

413
· On QFX3500 and QFX3600 switches running the original CLI, you cannot use ZTP to upgrade from Junos OS Release 12.2 or later to Junos OS Release 13.2X51-D15 or later.
· QFX5200 switches only work with HTTP in 15.1X53-D30. FTP and TFTP protocols are not supported.
·
· If you are performing Zero Touch Provisioning (ZTP) with a Junos OS image that contains enhanced automation for the QFX5100 switch, configure root authentication, and the provider name, license type, and deployment scope for Chef and Puppet at the [edit system] hierarchy in the configuration file that is fetched from the server:
{ master:0} root# set root-authentication (encrypted-password password | plain-text-password password | ssh-dsa public-key | ssh-rsa public-key) root# set extensions providers juniper license-type customer deployment-scope commercial root# set extensions providers chef license-type customer deployment-scope commercial
· In Junos OS Release 18.1R1, if you are upgrading the software, you must perform a full software upgrade. A full upgrade includes upgrading both the Junos OS software and the host software packages.
There are no caveats for Junos OS Evolved platforms.
Zero Touch Provisioning Using WAN Interfaces on PTX1000 Routers
Zero Touch Provisioning (ZTP) allows you to provision your router in your network automatically, with minimal manual intervention. Starting in Junos OS Release 19.3R1, you can use either WAN interfaces or management interfaces, to automatically download and install the appropriate software and the configuration file on your router during the ZTP bootstrap process.
When you connect the router to the network at the first time, you can choose any available WAN port on the router to connect the optics. The ZTP automatically configures WAN interfaces based on the optics type, and then connects your device to the Dynamic Host Configuration Protocol (DHCP) server to perform the bootstrap process.
The WAN interfaces created based on the optics type you connected to the device and the WAN interface speed auto-transitions through all possible supported port speeds until the ZTP gets completed successfully. The speed auto-transition ensures to establish physical link of the WAN port with the optics you connected and the peer end device connectivity to the DHCP server.
PTX1000 Port Mapping shows the available combinations for the ports on the PTX1000 routers.

414
Zero Touch Provisioning on PTX10008 Routers
Zero Touch Provisioning (ZTP) allows you to provision your router in your network automatically, with minimal manual intervention. Starting in Junos OS Evolved Release 20.1R1, the PTX10008 devices support automation of the device configuration and software upgrade over the management interface of Routing Engine 0 (RE0). ZTP is enabled on the PTX10008 device in the factory default mode. You can connect the management interface (re0:mgmt-0) to a network with a Dynamic Host Configuration Protocol (DHCP) server, and then add ZTP configuration to the DHCP server. Use the show interfaces re0:mgmt-0 command on the PTX10008 device to find the MAC address of the interface to use on the DHCP server configuration. When the PTX10008 device is able to contact the DHCP server and retrieve ZTP parameters, it performs the following ZTP operations based on these parameters: 1. Fetches the specified image and/or configuration file using the specified protocol.
2. If an image is specified, ZTP installs the image on both Routing Engines and reboots the device.
3. If a configuration file is specified: · If the file is a Junos configuration, ZTP applies the configuration on the device.
· If the file is a script, ZTP execute the script on the device.
Zero Touch Provisioning Using DHCP Options
Zero Touch Provisioning (ZTP) allows for automatic provisioning of Juniper Network devices that you add to your network. You can provision any supported device by using either a script to be executed or a configuration file to be loaded. You will also need to configure a DHCP server with required information, which is provided in this procedure, to use ZTP. ZTP requires that your device is in a factory default state. The device from the factory boots with preinstalled software and factory default configuration. On a device that does not currently have the factory default configuration, you can issue the request system zeroize command.
NOTE: The request system zeroize command is not supported on PTX1000, PTX10001-20C, QFX10002-60C, PTX10002-60C devices. You must issue the request vmhost zeroize command (instead of request system zeroize) for factory default configuration on PTX1000 routers.

415
NOTE: On PTX10001-20C devices, after you issue the the request vmhost zeroize command, you will see the following message twice: VMHost Zeroization : Erase all data, including configuration and log files ? [yes,no] (no) yes warning: Vmhost will reboot and may not boot without configuration Erase all data, including configuration and log files? [yes,no] (no) yes
Before you begin: · Ensure that the device has access to the following network resources:
· The DHCP server that provides the location of the software image and configuration files on the network Refer to your DHCP server documentation for configuration instructions.
· The File Transfer Protocol (anonymous FTP), Hypertext Transfer Protocol (HTTP), or Trivial File Transfer Protocol (TFTP) server on which the software image and configuration files are stored
NOTE: Although TFTP is supported, we recommend that you use FTP or HTTP instead, because these transport protocols are more reliable.
CAUTION: HTTP URLs are limited to 256 characters in length.
· A Domain Name System (DNS) server to perform reverse DNS lookup (not supported). · (Optional) An NTP server to perform time synchronization on the network · (Optional) A system log (syslog) server to manage system log messages and alerts.
Syslog messages will be forwarded to this syslog server during ZTP. · · Locate and record the MAC address for your device.
On PTX10008 devices, the management MAC addresses are located on routing engines.
CAUTION: You cannot commit a configuration while the device is performing the software update process. If you commit a configuration while the device is performing

416
the configuration file autoinstallation process, the process stops, and the configuration file is not downloaded from the network.
To enable zero touch provisioning for a device using DHCP options:
1. Boot the device. 2. Make sure the device has the default factory configuration installed.
Issue the request system zeroize command on the device that you want to provision.
NOTE: The request system zeroize command is not supported on PTX1000 devices. You must issue the request vmhost zeroize command (instead of request system zeroize) for factory default configuration on PTX1000 devices.
Starting in Junos OS Evolved Release 19.3R1, on QFX5220-128C device, in Zero Touch Provisioning (ZTP), you can use either WAN interfaces or management interfaces, to automatically download and install the appropriate software and the configuration file on your device during the bootstrap process. ZTP automatically configures on WAN port that has default port speed of 100Gbps, and then connects your device to the Dynamic Host Configuration Protocol (DHCP) server to perform the bootstrap process:
· If multiple DHCP replies arrive, the ZTP chooses the best set of arguments.
· If multiple interfaces provide the same arguments, ZTP chooses one of the interfaces.
· If there is an error while connecting to DHCP server, ZTP retry to connect DHCP server, and if multiple interfaces again provide same arguments, ZTP choose one of the interfaces.
We recommend you to provision the DHCP server and save the software and configuration file in the specified DHCP server path on the file server. 3. Download the software image file and/or the configuration file to the FTP, HTTP, or TFTP server from which the device will download these files.
NOTE: If you are performing zero touch provisioning with a Junos OS image that contains enhanced automation for the QFX5100 device, configure root authentication and the provider name, license type, and deployment scope for Chef and Puppet at the [edit system] hierarchy in the configuration file that is fetched from the server:
{ master:0} root# set root-authentication (encrypted-password password | plain-text-password password | ssh-dsa public-key | ssh-rsa public-key)

417
root# set extensions providers juniper license-type customer deployment-scope commercial root# set extensions providers chef license-type customer deployment-scope commercial
4. Configure the DHCP server to provide the necessary information to the device. Configure IP address assignment. You can configure dynamic or static IP address assignment for the management address of the device. To determine the management MAC address for static IP address mapping, add 1 to the last byte of the MAC address of the device, which you noted before you began this procedure.
NOTE: This address can be any address from the pool.
5. Define the format of the vendor-specific information for DHCP option 43 in the dhcpd.conf file. Here is an example of an ISC DHCP 4.2 server dhcpd.conf file:
option space NEW_OP; option; option NEW_OP.image-file-name code 0 = text; option NEW_OP.config-file-name code 1 = text; option NEW_OP.image-file-type code 2 = text; option NEW_OP.transfer-mode code 3 = text; option NEW_OP.alt-image-file-name code 4= text; option NEW_OP.http-port code 5= text; option NEW_OP-encapsulation code 43 = encapsulate NEW_OP;
NOTE: Starting in Junos OS Release 18.2R1, a new DHCP option is introduced to set the timeout value for the file downloads over FTP. If the transfer-mode is set as FTP, the default value for the timeout is automatically set as 120 minutes, that is, in case the FTP session gets interrupted due to loss of connectivity in the middle of a file transfer, it will timeout after 120 minutes and ZTP will attempt to retry the file fetching process. This value can be overridden using the DHCP option as follows:
option NEW_OP.ftp-timeout code 7 = text; option NEW_OP.ftp-timeout "

418
val";
where "val" is the user configurable timeout value in seconds and must be provided within quotes (like, "val").
6. Configure the following DHCP option 43 suboptions: · Suboption 00: The name of the software image file to install.
NOTE: When the DHCP server cannot use suboption 00, configure the software image filename using suboption 04. If both suboption 00 and suboption 4 are defined, suboption 04 is ignored.
option NEW_OP.image-file-name "/dist/images/jinstall-ex-4200-13.2R1.1-domestic-signed.tgz";
· Suboption 01: The name of the script or configuration file to install.
option NEW_OP.config-file-name "/dist/config/jn-switch35.config";
NOTE: ZTP determines if the file is a script file based on the first line of the file. If the first line contains the characters #! followed by an interpreter path, ZTP treats the file as a script and executes it with the specified interpreter path. In order for a script to execute, the script file must provide the ability to fetch and load a valid configuration file on the device during the ZTP process. The following list provides the types of scripts and their associated interpreter paths: · Shell script interpreter path: #!/bin/sh · SLAX script interpreter path: #!/usr/libexec/ui/cscript · Python script interpreter path: #!/usr/bin/python
For security reasons, Junos OS has strict requirements for running unsigned Python scripts on devices running Junos OS. Only devices running Junos OS with Enhanced Automation and devices running Junos OS Evolved support running unsigned Python scripts as part of the ZTP process.

419
If the file does not contain special characters (#!) , ZTP determines that the file is a configuration file and loads the configuration file.
· Suboption 02: The symbolic link to the software image file to install.
option NEW_OP.image-file-type "symlink";
NOTE: If you do not specify suboption 2, the ZTP process handles the image filename as a filename, not a symbolic link.
· Suboption 03: The transfer mode that the device uses to access the TFTP, FTP, or HTTP server. If you select FTP as the transfer mode, Junos OS uses the anonymous FTP login to download files from the FTP server.
option NEW_OP.transfer-mode "ftp";
NOTE: If suboption 03 is not configured, TFTP becomes the transfer mode by default.
· Suboption 04: The name of the software image file to install.
NOTE: If the DHCP server does not support suboption 00, configure the image file using suboption 04. If both suboption 00 and suboption 4 are defined, suboption 04 is ignored.
option NEW_OP.alt-image-file-name "/dist/images/jinstall-ex-4200-13.2R1.1-domestic-signed.tgz"; · Suboption 05: The HTTP port that the device uses to download either the image or
configuration file or both instead of the default HTTP port.
option NEW_OP.http-port code 5= 8080; 7. (Mandatory) Configure either option 150 or option 66.

420
NOTE: You must configure either option 150 or option 66. If you configure both option 150 and option 66, option 150 takes precedence, and option 66 is ignored. Also, make sure you specify an IP address, not a hostname, because name resolution is not supported.
· Configure DHCP option 150 to specify the IP address of the FTP, HTTP, or TFTP server.
option option-150 code 150={ ip-address}; option option-150 10.100.31.71;
· Configure DHCP option 66 to specify the IP address of the FTP, HTTP, or TFTP server.
option tftp-server-name "10.100.31.71"; 8. (Optional) Configure DHCP option 7 to specify one or more system log (syslog) servers.
option log-servers 10.100.31.72; 9. (Optional) Configure DHCP option 42 to specify one or more NTP servers.
List each NTP server separated by a space.
option ntp-servers 10.100.31.73; 10. (Optional) Configure DHCP option 12 to specify the hostname of the device.
option hostname "jn-switch35"; The following sample configuration shows the DHCP options you just configured in this procedure:
host jn-switch35 { hardware ethernet ac:4b:c8:29:5d:02; fixed-address 10.100.31.36; option tftp-server-name "10.100.31.71"; option NEW_OP.ftp-timeout " val"; option host-name "jn-switch35"; option log-servers 10.100.31.72;

421
option ntp-servers 10.100.31.73; option NEW_OP.image-file-name "/dist/images/jinstall-ex-4200-13.2R1.1domestic-signed.tgz"; option NEW_OP.transfer-mode "ftp"; option NEW_OP.http-port code 5= 8080; option NEW_OP.config-file-name "/dist/config/jn-switch35.config"; }
Based on the DHCP options configured in this example, the following items are added to the [edit system] hierarchy:
system { host-name jn-switch35;
syslog { host 10.100.31.72 { any any; }
} ntp {
server 10.100.31.73; } }
11. Connect the device to the network that includes the DHCP server and the FTP, HTTP, or TFTP server.
12. Power on the device. 13. Monitor the ZTP process by looking at the console.
NOTE: When SLAX scripts are executed, the op-script.log and event-script.log files are produced.
You can use these log files to troubleshoot in case something goes wrong. · /var/log/dhcp_logfile
Use this file to check DHCP client logs.
· /var/log/event-script.log Use this file to check configuration commit status.

422
· /var/log/image_load_log Use this file to check software image and configuration file fetch and installation status.
· /var/log/messages Use this file to check system-level logs.
· /var/log/op-script.log Use this file to check configuration commit status.
· /var/log/script_output Use this file to check script execution output.
For Junos OS Evolved, use the /var/log/ztp.log file to troubleshoot. You can also monitor the ZTP process by looking at error messages and issuing operational commands. See "Monitoring Zero Touch Provisioning" on page 438 for more information.
Zero Touch Provisioning Using DHCPv6 Options
The DHCPv6 protocol doesn't have a subnet option for the IA_NA (identity association for nontemporary addresses) to learn and install subnet routes. Instead, the subnet route is installed through Neighbor Discovery Protocol. In IPv6, devices periodically advertise IPv6 prefixes along with other link parameters using Router Advertisement (RA) messages. On the client (Juniper device running ZTP), once the DHCPv6 client is bound, the Neighbor Discovery Protocol (NDP) will learn these prefixes and installs the prefix routes via the client interface, with the next hop as the link to the local address of the gateway device. On the client device, router advertisement configuration is enabled by default along with the DHCPv6 configuration. · Ensure that the device has access to the following network resources:
· The DHCP server that provides the location of the software image and configuration files on the network Refer to your DHCP server documentation for configuration instructions.
· On the MX Series, the File Transfer Protocol (anonymous FTP), Trivial File Transfer Protocol (TFTP), Hypertext Transfer Protocol (HTTP), or Hypertext Transfer Protocol Secure (HTTPS) server on which the software image and configuration files are stored.

423
CAUTION: HTTP URLs are limited to 256 characters in length.
· On the EX3400, EX4300, QFX5100, and QFX5200 devices, the Hypertext Transfer Protocol (HTTP) or Hypertext Transfer Protocol Secure (HTTPS) server on which the software image and configuration files are stored.
CAUTION: HTTP URLs are limited to 256 characters in length.
· Locate and record the MAC address printed on the device. Zero Touch Provisioning (ZTP) allows for automatic provisioning of Juniper Network devices that you add to your network. You can provision any supported device by using either a script to be executed or a configuration file to be loaded. To use ZTP, you configure a DHCP server to provide the required information. If you do not configure the DHCP server to provide this information, the device boots with the preinstalled software and default factory configuration. If your device is not in a factory default state, you can issue the request system zeroize command.
NOTE: Starting in Junos OS Release 20.2R1-S1, the DHCPv6 client is supported the MX-Series, EX3400, EX4300, QFX5100, and QFX5200 switches. Both DHCPv4 and DHCPv6 clients are included as part of the default configuration. During the bootstrap process, the device first uses the DHCPv4 client to request for information regarding image and configuration file from the DHCP server. The device checks the DHCPv4 bindings sequentially. If there is a failure with one of the DHCPv4 bindings, the device will continue to check for bindings until provisioning is successful. If there are no DHCPv4 bindings, however, the device will check for DHCPv6 bindings and follow the same process as for DHCPv4 until the device can be provisioned successfully. The DHCP server uses DHCPv6 options 59 and 17 and applicable sub-options to exchange ZTP-related information between itself and the DHCP client.
CAUTION: You cannot commit a configuration while the device is performing the software update process. If you commit a configuration while the device is performing the configuration file autoinstallation process, the process stops, and the configuration file is not downloaded from the network.
To use zero touch provisioning for a device using DHCPv6 options: 1. Boot the device.

424
2. Make sure the device has the default factory configuration installed. · If multiple DHCP replies arrive, the ZTP chooses the best set of arguments. · If multiple interfaces provide the same arguments, ZTP chooses one of the equal interfaces. · If there is an error while connecting to the DHCP server, ZTP tries again to connect to the DHCP server. If multiple interfaces again provide the same arguments, ZTP chooses one of the interfaces. We recommend you to provision the DHCP server and save the software and configuration file in the specified DHCP server path on the file server.
3. Download the software image file and the configuration file to the FTP, HTTP, HTTPS, or TFTP server from which the device will download these files.
4. Configure the DHCP server to provide the necessary information to the device. 5. Configure IP address assignment.
You can configure dynamic or static IP address assignment for the management address of the device. To determine the management MAC address for static IP address mapping, add 1 to the last byte of the MAC address of the device, which you noted before you began this procedure. 6. Define the format of the DHCPv6 option 59 (OPT_BOOTFILE_URL) in the dhcpd6.conf file, so the server can send information about URLs to images to the client.
NOTE: Only the HTTP and HTTPS transport protocols are supported on the EX3400, EX4300, QFX5100, and QFX5200 devices.
Here's the format for this option:
transfer-mode://[<ipv6-address>]:<port-number>/<path/image-file-name>
For example:
ftp://[2001:db8::40]:21/ZTP/bootimage.tgz tftp://[2001:db8::40]:69/ZTP/bootimage.tgz http://[2001:db8::40]:80/ZTP/bootimage.tgz https://[2001:db8::40]:443/ZTP/bootimage.tgz
The transfer mode and IPv6 address are required, but the port number is optional. If you do not specify the port number, the default port number of the transfer mode is used. If you specify the port number in options 17 and 59, then the port number mentioned in option 17 vendor-specific information option is used.

425
You can specify the image file name in either option 59 or option 17. If the image file name is mentioned in both options 59 and 17, then the image name mentioned in option 17 vendor-specific information option is used. 7. Define the format of the vendor-specific information for the following DHCP option 17 suboptions: Here is an example of an ISC DHCP 4.2 server dhcpd6.conf file:
option space NEW_OP_V6 code width 2 length width 2; option NEW_OP_V6.image-file-name code 0 = text; option NEW_OP_V6.config-file-name code 1 = text; option NEW_OP_V6. image-file-type code 2 = text; option NEW_OP_V6.transfer-mode code 3 = text; option NEW_OP_V6. alt-image-file-name code 4 = text; option NEW_OP_V6.port-number code 5 = text; option NEW_OP_V6. jloader-file code 6 = text; option NEW_OP_V6. ftp-timeout code 7 = text option vsio.NEW_OP_V6 code 2636 = encapsulate NEW_OP_V6;
· Suboption 00: The name of the software image file to install.
NOTE: When the DHCP server cannot use suboption 00, configure the software image filename using suboption 04. If both suboption 00 and suboption 4 are defined, suboption 04 is ignored.
option NEW_OP_V6.image-file-name "ZTP_IMAGES/jinstall-qfx-5-20.2-img.tgz";
· Suboption 01: The name of the script or configuration file to install.
option NEW_OP_V6.config-file-name "ZTP_FILES/baseline_config";
NOTE: ZTP determines if the file is a script file based on the first line of the file. If the first line contains the characters #! followed by an interpreter path, ZTP treats the file as a script and executes it with the specified interpreter path. In order for a script to execute, the script file must provide the ability to fetch and load a valid configuration file on the device during the ZTP process.

426
The following list provides the types of scripts and their associated interpreter paths: · Shell script interpreter path: #!/bin/sh · SLAX script interpreter path: #!/usr/libexec/ui/cscript · Python script interpreter path: #!/usr/bin/python
For security reasons, Junos OS has strict requirements for running unsigned Python scripts on devices running Junos OS. Only devices running Junos OS with Enhanced Automation and devices running Junos OS Evolved support running unsigned Python scripts as part of the ZTP process. If the file does not contain special characters (#!) , ZTP determines that the file is a configuration file and loads the configuration file.
· Suboption 02: The image type.
option NEW_OP_V6.image-file-type symlink;
NOTE: If you do not specify suboption 2, the ZTP process handles the software image as a filename, not a symbolic link.
· Suboption 03: The transfer mode that the device uses to access the TFTP, FTP, HTTP, or HTTPS server.
option NEW_OP_V6.transfer-mode "https";
NOTE: If suboption 03 is not configured, the transfer mode mentioned in option 59 for the boot image URL is used.
· Suboption 04: The name of the software image file to install.

427
NOTE: When the DHCP server cannot use suboption 00, configure the image file using suboption 04. If both suboption 00 and suboption 4 are defined, suboption 04 is ignored.
option NEW_OP_V6. alt-image-file-name "ZTP_IMAGES/jinstall-qfx-5-20.2-alternate-img.tgz";
· Suboption 05: The port that the device uses to download either the image or configuration file or both instead of the default port.
option NEW_OP_V6.port-number 8080;
· Suboption 06: The JLoader package file name (supported only on QFX5100 devices)
option NEW_OP_V6. "jloader.tgz";
· Suboption 07: FTP timeout code.
option NEW_OP_V6. ftp-timeout "val";
· The DHCPv6 protocol defines the Vendor-specific Information Option ("VSIO") in order to send vendor options encapsulated in a standard DHCP option.
option vsio.NEW_OP_V6 code 2636 = encapsulate NEW_OP_V6;
The following sample configuration shows the DHCPv6 options you've just configured:
subnet6 2001:db8::/32 { range6 2001:db8::10 2001:db8::40;
} host chocolate {
option host-name chocolate; hardware ethernet 00:a0:a5:7b:cd:38; fixed-address6 2001:db8::11; option dhcp6.bootfile-url "https://[2001:db8::1]"; option NEW_OP_V6.image-file-name "ZTP_IMAGES/jinstall-qfx-5-20.2I-

428
img.tgz"; option NEW_OP_V6.port-number 8080; option NEW_OP_V6.config-file-name "ZTP_FILES/baseline_config"; option NEW_OP_V6.image-file-type symlink; option NEW_OP_V6.transfer-mode "https"; option NEW_OP_V6.jloader-file "jloader.tgz "
}
8. Power on the device with the default configuration. 9. Monitor the ZTP process by looking at the the console.
NOTE: When SLAX scripts are executed, the op-script.log and event-script.log files are produced.
You can also use these log files to troubleshoot in case something goes wrong. · /var/log/dhcp_logfile
Use this file to check DHCP client logs. · /var/log/event-script.log
Use this file to check configuration commit status. · /var/log/image_load_log
Use this file to check software image and configuration file fetch and installation status. · /var/log/messages
Use this file to check system-level logs. · /var/log/op-script.log
Use this file to check configuration commit status. · /var/log/script_output
Use this file to check script execution output. You can also monitor the ZTP process by looking at error messages and issuing operational commands. See "Monitoring Zero Touch Provisioning" on page 438 for more information.

429
Zero Touch Provisioning on SRX Series Devices
IN THIS SECTION Understanding Zero Touch Provisioning on SRX Series Devices | 429 Configuring Zero-Touch Provisioning on an SRX Series Device | 433 Understanding Factory-Default Configuration on SRX Series Device for Zero Touch Provisioning | 437
Understanding Zero Touch Provisioning on SRX Series Devices
IN THIS SECTION Understanding ZTP on SRX Series Devices | 429 Network Activator Overview | 430 Limitations | 433
This topic includes following sections: Understanding ZTP on SRX Series Devices Zero Touch Provisioning (ZTP) enables you to provision and configure devices automatically, minimizing most of the manual intervention required for adding devices to a network. ZTP is supported on SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX1500 devices. Starting in Junos OS Release 20.2R1 on SRX300, SRX320, SRX340, SRX345, SRX550 HM, and SRX1500 devices, you can use Zero Touch Provisioning with DHCP options to provision your device. See "Zero Touch Provisioning Using DHCP Options" on page 414 for more information. ZTP on SRX Series devices is responsible for the initial bootup and configuration of the device when the device is powered on. This functionality includes: · Providing the bare-minimum bootstrapping of the device. The SRX Series device is shipped with a
factory-default configuration. The factory-default configuration includes the URL of the redirect server, that is used to connect to the central server by using a secure encrypted connection.

430
· Automatically connecting to the server over the Internet, and downloading the configuration and Junos OS image as specified by the customer or user from the server when the SRX Series device boots up with the factory-default configuration. The new image is installed first and then the initial configuration is applied and committed on the SRX Series device.
ZTP offers the following advantages:
· Simplified and faster deployment
· Increased configuration accuracy
· Support for scaling of network without additional resources
The ZTP process uses Network Activator to initially provision SRX Series devices.
Network Activator Overview
Network Service Activator enables fast device discovery and provisioning for automated configuration to eliminate complex device setup.
Network Activator initially provisions SRX Series devices (henceforth referred to as remote devices in this documentation), which reside at end users' sites. The remote devices download a boot image and initial configuration files from servers hosting Network Activator, using a process that provides full authorization and authentication for all interactions. When initial provisioning is complete, the remote device communicates with a management server, which then starts to manage and monitor the remote device.
Network Activator uses a distributed architecture to support remote devices. Network Activator is installed on one central administration server (central server) and multiple regional administration servers (regional servers). A device communicates directly with its assigned regional server. The distributed architecture optimizes the efficiency of the initial provisioning process, contributing to high performance and scaling of the network.

431 Figure 18 on page 431 Illustrates the distributed architecture and the components involved in the initial provisioning process. Figure 18: Components Involved in Initial Provisioning of Remote Device
The roles of the components in the initial provisioning process are as follows: · The remote device sends requests for initial provisioning. The remote device resides at the end user's
location. · The Redirect Tool provides authentication and authorization for remote devices to access their
assigned regional servers through use of ITU-T X.509 private key infrastructure (PKI) digital certificates. Redirect service is hosted on Amazon Web Services (AWS), operated and maintained by Juniper Networks. · The central server hosts Network Activator and communicates with the regional activator servers. Administrators at a service provider or central enterprise location interact with this server to install and set up Network Activator. The central server is located at a central geographic location for the service provider. · The regional server also hosts Network Activator. This server stores information about its assigned remote devices and communicates directly with those devices. This server typically resides at a regional administrative location the provider designates for the end user.

432 Figure 19 on page 432 illustrates the initial provisioning workflow. Figure 19: Workflow for Initial Provisioning
In detail, the provisioning workflow proceeds as follows: 1. The administrator at the service provider:
· Installs and sets up Network Activator on the central server. · Adds remote devices and regional servers in the Redirect Tool. 2. The central server forwards the installation to the regional servers. 3. The end user powers on the remote device, connects it to a computer, and enters the authentication code in the webpage to send a request for initial provisioning.

433
4. The device transmits its X.509 certificate and fully qualified domain name (FQDN) as a provisioning request to the Redirect Tool.
5. The Redirect Tool searches its data store for the regional server that the administrator specified for this device, and confirms that the device's request corresponds to the X.509 certificate specified for the server.
6. The Redirect Tool sends contact information for the regional server to the device.
7. The device sends a request to the regional server for the URL of the boot image and the location of the initial configuration.
8. The regional server sends the information to the device.
9. The device obtains the boot image and configuration from the regional server.
10. The device uses the boot image and configuration to start and become operational.
Limitations
· There are no restrictions on the number of attempts for entering the correct activation code.
· If the remote device is not able to reach the server (because the configured address in the factorydefault configuration is not correct or the server is down, and so on), the remote device attempts to connect to an alternative server (if configured in the factory-default configuration). If there is only one server configured, then you can reattempt to connect. In such scenarios, we recommend that you configure the device manually through the console.
· Captive portal redirection, required for automatically redirecting users to the authentication webpage for entering the activation code, is not supported. You must manually navigate to the activation page after connecting to the device.
Configuring Zero-Touch Provisioning on an SRX Series Device
Before you begin:
· Unpack the device, install it, complete the necessary cabling, connect a laptop or any other terminal device, and power on the device. See the Hardware installation Guide for your device for more information.
· For SRX300, SRX320, SRX340, SRX345, and SRX550M devices, connect the management device and access the J-Web interface.
For more information, see Quick Start guides of respective devices at SRX300, SRX320, SRX340, SRX345, and SRX550M.

434
You are provided with an option to use ZTP; you can use this option or skip it and continue with JWeb wizards. · For SRX1500 devices, before you can use J-Web to configure your device, you must access the CLI to configure the root authentication and the management interface. For more information, see How to Set Up Your SRX1500 Services Gateway. This section provides step-by-step instructions on how to use ZTP on an SRX Series device for initial provisioning of the device. To provision an SRX Series device by using ZTP: 1. Connect a management device (PC or laptop) to any front panel Ethernet port (WAN port) of the SRX Series device. 2. Launch a Web browser from the management device and enter the authentication code in the webpage as shown in Figure 20 on page 434.
Figure 20: Entering Activation Code for ZTP

435 After the device is successfully authenticated, it starts downloading the software image and initial configuration from the server as shown in Figure 21 on page 435. Figure 21: Initiating ZTP Process (Software Image Downloading)
At this step: · The activation code is sent to the server, and if the authentication is successful, the server pushes
the initial configuration to the device. If the authentication is unsuccessful, you are asked to provide the correct code. · The server can optionally pushes a new software image on the SRX Series device. In that case, the new image is installed first and then the initial configuration is applied and committed on the device.

436 The new image is installed and then the initial configuration is applied and committed on the device. When the process is complete, a confirmation message is displayed, as shown in Figure 22 on page 436. Figure 22: Completing ZTP Process
3. Click Logs to display details of the bootstrapping process. After successfully installing the new software image and configuration on the system, the client sends the bootstrap-complete notification to the server that provided the image and the configuration. After the notification is sent, the configuration that includes the names of servers is deleted from the system. When you use ZTP the next time, you must explicitly configure the URL of the redirect server.
NOTE: In case of failure at any stage, the procedure is started all over again.
NOTE: The ZTP process either upgrades or downgrades the Junos OS version. During a downgrade on an SRX Series device, if you downgrade to a software version earlier than Junos OS Release 15.1X49-D100, in which ZTP is not supported, the autoinstallation phase of the ZTP process does not happen. For SRX300, SRX320, SRX340, SRX345, and SRX550M devices, ZTP is the default method for provisioning the devices. However, if you want to use J-Web-based provisioning (J-Web setup wizards supported for the SRX300 line of devices and SRX550M devices), then instead of ZTP, you can use the

437 option provided in the client portal to skip to J-Web setup wizards for performing the initial software configuration of your device. If you select the Skip to JWeb option, you must configure the system root authentication password as shown in Figure 23 on page 437. Figure 23: Configuring System Root-Authentication Password
NOTE: For SRX1500 devices, the Skip to JWeb option is not supported. To access J-Web, the ZTP client configuration must be deleted during the initial setup of SRX1500 through CLI.
Understanding Factory-Default Configuration on SRX Series Device for Zero Touch Provisioning
Your services gateway is shipped with a factory-default configuration. Following is a sample of the default configuration that includes configuration for ZTP:
system { phone-home { rfc-compliant; server https://redirect.juniper.net;

438
} }
Note that, in this configuration: · server indicates the name or IP address of the server. The factory-default configuration on an SRX
Series device might include IP addresses of more than one servers. · rfc-compliant indicates that after an upgrade, the server enforces certain behaviors that are
compliant with RFC standards.
NOTE: By default, the system autoinstallation configuration is part of the factory-default configuration of the device. So, the administrator must ensure that the configuration file sent from the regional server to the remote device (SRX series device) must include the delete system autoinstallation option in the factory-default configuration.
Monitoring Zero Touch Provisioning
IN THIS SECTION Using the Console to Monitor Zero Touch Provisioning | 439 Using System Log Alerts to Monitor Zero Touch Provisioning | 439 Using Error Messages to Monitor Zero Touch Provisioning | 440 Using System Log Files to Monitor Zero Touch Provisioning in Junos OS Using DHCP Options | 441 Using System Log Files to Monitor Zero Touch Provisioning in Junos OS Using DHCPv6 Options | 442 Using the Console to Monitor Zero Touch Provisioning in Junos OS Evolved | 443 Using the show dhcp client binding Command | 446 Using the show dhcpv6 client binding Command | 447 Using the show dhcp client statistics Command | 448 Using the show dhcpv6 client statistics Command | 449
Starting in Junos OS Release 12.2, you can use the console and operational commands to monitor Zero Touch Provisioning.

439
Starting in Junos OS Evolved Release 19.1R1, to monitor zero touch provisioning on Junos OS Evolved, use the show system ztp command.
Using the Console to Monitor Zero Touch Provisioning
The following Zero Touch Provisioning (ZTP) activities are displayed on the console during the ZTP process: · Starting and ending times of ZTP process. · Lists of bound and unbound DHCP client interfaces. · DHCP options that DHCP servers send to DHCP clients. · Logs indicating which interfaces are used for ZTP. · ZTP parameters that DHCP clients obtain from DHCP servers. · Filenames of configuration and image files, names of file servers, protocols used to fetch files, and
times when DHCP servers fetch configuration and image files. · Failure states caused by files not being on servers, or unreachable servers, and time outs. · Number of attempts made, and number of attempts remaining, for retry in current ZTP cycle. · Completion of file transfers. · Installation, reboot, and state of ZTP process. · Internal state errors and termination of ZTP process. · Logs for when default routes were added or deleted.
Using System Log Alerts to Monitor Zero Touch Provisioning
IN THIS SECTION Purpose | 439 Action | 440 Meaning | 440
Purpose In this example, the system log alert alerts you that the auto-image upgrade will start.

440
Action Use the following system log alert to monitor the auto-image upgrade process.
"ALERT:Auto-image upgrade will start. This can terminate config CLI session(s). Modified configuration will be lost. To stop Auto-image, in CLI do the following: 'edit; delete chassis auto-image-upgrade; commit'." "Checking whether image upgrade is already invoked"
Meaning This system log alert indicates that the auto-image upgrade will start, and provides information on how to stop the auto-image upgrade process.
Using Error Messages to Monitor Zero Touch Provisioning
IN THIS SECTION Purpose | 440 Action | 440 Meaning | 441
Purpose Error messages provide information on which DHCP options are not configured. Action Use the information in the following error message to find out which DHCP options are not configured.
"DHCP Log Server Option" "DHCP Host Name Option" "DHCP NTP Server Option"

441
Meaning The error message indicates that the DHCP log server, hostname, and NTP server options are not configured.
Using System Log Files to Monitor Zero Touch Provisioning in Junos OS Using DHCP Options
IN THIS SECTION Purpose | 441 Action | 441 Meaning | 442
Purpose System log files provide information on the state of the auto-upgrade process, lists of bound and unbound DHCP client interfaces, IP addresses of file servers, names and locations of image and configuration files, and successful and failed attempts at fetching configuration and image files. Action Use the information in the following system log files to monitor the auto-upgrade process.
Auto Image Upgrade: Start fetching config-file file from server 10.1.1.1 through irb using ftp
Auto Image Upgrade: Tried [2] attempts to fetch config-file file from server 10.1.1.1 through irb. Summary: "Retrieving /config-file :: Failed to open file.". To retry [4] times.
Auto Image Upgrade: Tried [4] attempts to fetch config-file file from server 10.1.1.1 through irb. Summary: "Retrieving /config-fileconfig-file :: Failed to open file.". To retry [2] times. Auto Image Upgrade: Tried [6] attempts to fetch config-file file from server

442
10.1.1.1 through irb. Summary: "Retrieving /config-file :: Failed to open file.". To retry [0] times.
Auto Image Upgrade: All [6] attempts to fetch config-file file from server 10.1.1.1 through irb FAILED. Start retry again in few minutes.
Meaning These system log files indicate that there were six failed attempts to fetch the configuration file from the file server, the IP address of the file server, the DHCP client interface name, and the number of times the retry process occurred.
Using System Log Files to Monitor Zero Touch Provisioning in Junos OS Using DHCPv6 Options
IN THIS SECTION Purpose | 442 Action | 442 Meaning | 443
Purpose System log files provide information on the state of the auto-upgrade process, lists of bound and unbound DHCP client interfaces, IP addresses of file servers, names and locations of image and configuration files, and successful and failed attempts at fetching configuration and image files.
Action Use the information in the following system log files to monitor the auto-upgrade process.
Auto Image Upgrade: Tried [2] attempts to fetch junos-vmhost-install -20.2.tgz file from server 2001:db8::1 through et-0 /0/0:2. Summary: "fetch-secure: https://[2001:*: Connection refused". To retry [4] times.

443
Auto Image Upgrade: Tried [4] attempts to fetch junos-vmhost-install -20.2.tgz file from server 2001:db8::1 through et-0 /0/0:2. Summary: "fetch-secure: https://[2001:*: Connection refused". To retry [2] times.
Auto Image Upgrade: Tried [6] attempts to fetch junos-vmhost-install20.2.tgz file from server 2001:db8::1 through et-0 /0/0:2. Summary: "fetch-secure: https://[2001:*: Connection refused". To retry [0] times.
Meaning These system log files indicate that there were six failed attempts to fetch the image file from the file server, the IP address of the file server, the DHCPv6 client interface name, and the number of times the retry process occurred.
Using the Console to Monitor Zero Touch Provisioning in Junos OS Evolved
IN THIS SECTION Purpose | 443 Action | 443 Meaning | 446
Purpose System log files provide information on the state of the auto-upgrade process, lists of bound and unbound DHCP client interfaces, IP addresses of file servers, names and locations of image and configuration files, and successful and failed attempts at fetching configuration and image files.
Action Use the information in the console to monitor the auto-upgrade process. Here is an example of output for Junos OS Evolved.
164.319243] ztp.py[15456]: 2019-07-11 17:54:25 INFO: ZTP: Booted with factory settings set auto-image-upgrade

444
ztp.py[15456]: 2019-07-11 17:54:26 INFO: ZTP: loading config [ 184.456977] ztp.py[15456]: 2019-07-11 17:54:45 INFO: ZTP: Releasing prior dhcp state [ 184.520075] ztp.py[15456]: 2019-07-11 17:54:46 INFO: ZTP: initializing [ 184.520736] ztp.py[15456]: 2019-07-11 17:54:46 INFO: ZTP: Interface vmb0 Watching path /var/db/scripts/ztp/ztpopt.vmb0 [ 184.566657] ztp.py[15456]: 2019-07-11 17:54:46 INFO: ZTP: Interface vmb0v6 Watching path /var/db/scripts/ztp/ztpopt6.vmb0 [ 184.603976] ztp.py[15456]: 2019-07-11 17:54:46 INFO: ZTP: remove "chassis auto-image-upgrade" from config to abort ZTP [ 184.605897] ztp.py[15456]: 2019-07-11 17:54:46 INFO: ZTP: send DHCP discover on interface vmb0 [ 184.606083] ztp.py[15456]: 2019-07-11 17:54:46 INFO: ZTP: send DHCP discover on interface vmb0v6 [ 205.043925] ztp.py[15456]: 2019-07-11 17:55:06 INFO: ZTP: loading options config [ 225.528749] ztp.py[15456]: 2019-07-11 17:55:27 INFO: ZTP:(vmb0) Running: ['/ sbin/dhclient', '-1', '-v', 'vmb0', '-cf', '/var /db/scripts/ztp/dhclient.conf', '-pf', '/var/db/scripts/ztp/vmb0.pid4'] [ 227.349638] ztp.py[15456]: 2019-07-11 17:55:28 INFO: ZTP: loading options config [ 248.512666] ztp.py[15456]: 2019-07-11 17:55:50 INFO: ZTP:(vmb0) Running: ['/ sbin/dhclient', '-6', '-D', 'LL', '-1', '-v', 'v mb0', '-cf', '/var/db/scripts/ztp/dhclient6.conf', '-pf', '/var/db/scripts/ztp/ vmb0.pid6'] [ 309.448411] ztp.py[15456]: 2019-07-11 17:56:50 ERROR: ZTP:(vmb0v6) Unable to get DhcpInfo [ 309.452340] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 ipaddr is 10.10.213.111 [ 309.453114] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 subnetmask is 255.255.255.0 [ 309.453379] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 option150addr is 10.10.213.1 [ 309.453619] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 option66addr is 10.10.213.1 [ 309.453836] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 host-name is sw-s3-u8-07 [ 309.454093] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 ntp server is ['10.129.255.62'] [ 309.454267] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 ntp server is ['10.129.255.62', '10.129.255.63'] [ 309.454451] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 log server is 10.10.213.1

445
[ 309.454673] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 image path is /ZTP_IMAGES/junos-evo-install-ptx-chassis-x 86-64-19.4EVO.iso [ 309.454886] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 config path is /ZTP_CONFIG/sw-s3-u8-07.cfg [ 309.455217] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: intf vmb0 transfertype is tftp [ 309.457209] ztp.py[15456]: 2019-07-11 17:56:50 INFO: ZTP: Chose interface vmb0: [ 309.633177] ztp.py[15456]: 2019-07-11 17:56:51 INFO: ZTP: loading options config [ 333.584288] ztp.py[15456]: 2019-07-11 17:57:15 INFO: ZTP: downloading image file/ZTP_IMAGES/junos-evo-install-ptx-chassis-x86 -64-19.4-20190708.2-EVO.iso [ 333.584840] ztp.py[15456]: 2019-07-11 17:57:15 INFO: ZTP: downloading image file local /var/tmp/junos-evo-install-ptx-chassis -x86-64-19.4-20190708.2-EVO.iso [ 554.625986] ztp.py[15456]: No such vrf (None) [ 554.628523] ztp.py[15456]: 2019-07-11 18:00:56 INFO: ZTP: Downloaded image file [ 554.629289] ztp.py[15456]: 2019-07-11 18:00:56 INFO: ZTP: Downloading config file /ZTP_CONFIG/sw-s3-u8-07.cfg [ 555.198176] ztp.py[15456]: No such vrf (None) [ 555.200076] ztp.py[15456]: 2019-07-11 18:00:56 INFO: ZTP: Downloaded config file [ 555.201882] ztp.py[15456]: 2019-07-11 18:00:56 INFO: ZTP: loading options config
577.427218] ztp.py[15456]: 2019-07-11 18:01:18 INFO: ZTP: Upgrading image [ 577.427770] ztp.py[15456]: 2019-07-11 18:01:18 INFO: ZTP: Upgraded image localpath is /var/tmp/junos-evo-install-ptx-chassis-x86-64-19.4EVO.iso [ 577.483927] ztp.py[15456]: 2019-07-11 18:01:19 INFO: ZTP: Installing via CLI (/var/tmp/junos-evo-install-ptx-chassis-x86-64-19.4-20190708.2-EVO.iso) [ 577.484271] ztp.py[15456]: 2019-07-11 18:01:19 INFO: ZTP: Running: ['/usr/ sbin/cli', '-c', 'show chassis hardware | display xml | match <name> | match "CB" | count'] [ 577.775918] ztp.py[15456]: 2019-07-11 18:01:19 INFO: ZTP: Dual-RE setup detected [ 577.776130] ztp.py[15456]: 2019-07-11 18:01:19 INFO: ZTP: Checking for second RE [ 577.776894] ztp.py[15456]: 2019-07-11 18:01:19 INFO: ZTP: Running: ['/usr/ sbin/cli', '-c', 'show chassis hardware | display xml | match <name> | match "Routing Engine" | count'] [ 577.987278] ztp.py[15456]: 2019-07-11 18:01:19 INFO: Running: ['/usr/sbin/

446

cli', '-c', 'request system software add /var/tmp/junos-evo-install-ptx-chassis-

x86-64-19.4EVO.iso | display xml']

[ 738.153925] ztp.py[15456]: 2019-07-11 18:03:59 INFO: ZTP: wait returns: 0

[ 738.154148] ztp.py[15456]: 2019-07-11 18:03:59 INFO: ZTP: Return Code: 0

[ 738.154281] ztp.py[15456]: 2019-07-11 18:03:59 INFO: ZTP: Upgraded image

status is 0

[ 738.154749] ztp.py[15456]: 2019-07-11 18:03:59 INFO: ZTP: Upgrade succeeded

Rebooting

[ 738.155372] ztp.py[15456]: 2019-07-11 18:03:5

Stopping Ethernet

Bridge Filtering Tables...

Meaning The console shows the progress of ZTP.
Using the show dhcp client binding Command

IN THIS SECTION
Purpose | 446 Action | 446 Meaning | 447

Purpose Issue the show dhcp client binding command to display DHCP client binding information
NOTE: This command does not apply to Junos OS Evolved.
Action Issue the show dhcp client binding command to display the IP address of the DHCP client, the hardware address of the DHCP client, number of seconds in which the DHCP client's IP address lease expires, state of the DHCP client IP address in the binding table, and the name of the interface that has active client bindings.

447

show dhcp client binding

user@device# show dhcp client binding

IP address

Hardware address Expires

10.0.0.0

00:22:83:2a:db:dc 0

10.6.6.13

00:22:83:2a:db:dd 49201

10.0.0.0

00:22:83:2a:db:df 0

10.0.0.0

00:22:83:2a:db:e0 0

State

Interface

SELECTING irb.0

BOUND

vme.0

SELECTING xe-0/0/0.0

SELECTING xe-0/0/1.0

Meaning
The output of this command shows that there is one client interface that is bound, and that there are three interfaces that are receiving DHCP offers from the DHCP server.
Using the show dhcpv6 client binding Command

IN THIS SECTION
Purpose | 447 Action | 447 Meaning | 448

Purpose Issue the show dhcpv6 client binding command to display DHCP client binding information
NOTE: This command does not apply to Junos OS Evolved.
Action Issue the show dhcp6 client binding command to display the IP address of the DHCPv6 client, the hardware address of the DHCPv6 client, number of seconds in which the DHCPv6 client's IP address lease expires, state of the DHCPv6 client IP address in the binding table, and the name of the interface that has active client bindings.

448

show dhcpv6 client binding

user@device# show dhcpv6 client binding

IP/prefix

Expires State

Interface

Client DUID

2001:db8::10

57

em0.0

LL0x3-54:4b:8c:d3:a2:34

2001:db8::10

46

em2.0

LL0x3-54:4b:8c:d3:a2:35

2001:db8::10

38

et-0/0/0:0.0

LL0x3-54:4b:8c:d3:a2:3b

2001:db8::10

530

et-0/0/0:1.0

LL0x3-54:4b:8c:d3:a2:3c

ClientType

SELECTING STATEFUL

SELECTING STATEFUL

SELECTING STATEFUL

BOUND

STATEFUL

Meaning
The output of this command shows that there is one client interface that is bound, and that there are three interfaces that are receiving DHCPv6 offers from the DHCP server.
Using the show dhcp client statistics Command

IN THIS SECTION
Purpose | 448 Action | 448 Meaning | 449

Purpose Issue the show dhcp client statistics command to display DHCP client statistics.
Action Issue the show dhcp client statistics command to display DHCP client statistics, such as the number of packets dropped, and the number DHCP and BOOTP messages sent and received.

449

show dhcp client statistics

user@device# show dhcp client statistics

Packets dropped:

Total

14

Send error

14

Messages received:

BOOTREPLY

5

DHCPOFFER

1

DHCPACK

4

DHCPNAK

0

DHCPFORCERENEW

0

Messages sent:

BOOTREQUEST

6751

DHCPDECLINE

0

DHCPDISCOVER

6747

DHCPREQUEST

4

DHCPINFORM

0

DHCPRELEASE

0

DHCPRENEW

0

DHCPREBIND

0

Meaning
The output of this command displays how many packets were dropped with errors, the number of BOOTREPLY and DHCPOFFER messages that were received, and the number of BOOTREQUEST and DHCPREQUEST messages that were sent.
Using the show dhcpv6 client statistics Command

IN THIS SECTION
Purpose | 450 Action | 450 Meaning | 450

450

Purpose Issue the show dhcpv6 client statistics command to display DHCPv6 client statistics.
Action Issue the show dhcpv6 client statistics command to display DHCPv6 client statistics, such as the number of packets dropped, and the number of DHCPv6 messages sent and received. show dhcpv6 client statistics

user@device# show dhcpv6 client statistics

Dhcpv6 Packets dropped:

Total

20323

Bad Send

7580

Bad Options

12743

Messages received:

DHCPV6_ADVERTISE

13

DHCPV6_REPLY

109

DHCPV6_RECONFIGURE

0

Messages sent:

DHCPV6_DECLINE

0

DHCPV6_SOLICIT

879

DHCPV6_INFORMATION_REQUEST 0

DHCPV6_RELEASE

0

DHCPV6_REQUEST

9

DHCPV6_CONFIRM

0

DHCPV6_RENEW

61

DHCPV6_REBIND

41

Meaning
The output of this command displays how many packets were dropped with errors, and the number of DHCPV6 messages that were received and sent.

451

Release History Table Release Description

19.1-Evo Starting in Junos OS Evolved Release 19.1R1, to monitor zero touch provisioning on Junos OS Evolved, use the show system ztp command.

12.2

Starting in Junos OS Release 12.2, you can use the console and operational commands to monitor Zero

Touch Provisioning.

Release History Table Release Description

21.1R1

Starting in Junos OS Release 21.1R1, on EX2300, EX2300-VC, EX3400, EX3400-VC, EX4400-24T, EX4400-48F, EX4400-48T, and EX4600 devices, during the bootstrapping process, the phone-home client can access the redirect server through a proxy server. The DHCP server uses DHCP option 43 suboption 8 to deliver the details of IPv4 and/or IPv6 proxy servers to the phone-home client. The DHCP daemon running on the target switch learns about the proxy servers in the initial DHCP cycle and then populates either the phc_vendor_specific_info.xml or the phc_v6_vendor-specific_info.xml files located in the /var/etc/ directory with the vendor-specific information.

21.1R1

Starting in Junos OS Release 21.1R1, on EX2300, EX2300-VC, EX3400, EX3400-VC, EX4400-24T, EX4400-48F, EX4400-48T, and EX4600 devices, when the phone-home client receives information regarding the HTTP proxy server via DHCP option 43 suboption 8, it will create an HTTPS transparent tunnel with the proxy server. Once the tunnel is established, the phone-home client uses the tunnel as a proxy for the phone-home server or redirect server. The phone-home client downloads the software image and configuration file through the tunnel onto the device. Once bootstrapping is complete, the device reboots and the tunnel quits.

20.4R1EVO

Starting in Junos OS Evolved Release 20.4R1, PTX10004 devices support automation of the device configuration and software upgrade over the management interface of Routing Engine 0 (RE0).

20.4R1EVO

Starting in Junos OS Evolved Release 20.4R1, ACX5448 and QFX5120-48YM devices support the ability for either WAN interfaces or management interfaces to automatically download and install the appropriate software and the configuration file on your device during the ZTP bootstrap process.

452

20.4R1

Starting in Junos OS Release 20.4R1 on the MX-Series, EX3400, EX4300, QFX5100, and QFX5200 devices, ZTP supports the DHCPv6 client. During the bootstrap process, the device first uses the DHCPv4 client to request for information regarding image and configuration file from the DHCP server. The device checks the DHCPv4 bindings sequentially. If there is a failure with one of the DHCPv4 bindings, the device will continue to check for bindings until provisioning is successful. If there are no DHCPv4 bindings, however, the device will check for DHCPv6 bindings and follow the same process as for DHCPv4 until the device can be provisioned successfully. The DHCP server uses DHCPv6 options 59 and 17 and applicable sub-options to exchange ZTP-related information between itself and the DHCP client.

20.4R1

Starting in Junos OS Release 20.4R1 on the EX4600, EX4650, EX9200 with RE-S-EX9200-2X00X6, QFX5110, QFX5200, QFX5210, QFX5120-32C, and QFX5120-48Y devices, you can use either the legacy DHCP-options-based ZTP or the phone-home client (PHC) to provision software for the switch. When the switch boots up, if there are DHCP options that have been received from the DHCP server for ZTP, ZTP resumes. If DHCP options are not present, PHC is attempted. PHC enables the switch to securely obtain bootstrapping data, such as a configuration or software image, with no user intervention other than having to physically connect the switch to the network. When the switch first boots up, PHC connects to a redirect server, which redirects to a phone home server to obtain the configuration or software image.

20.2R1-S1

Starting in Junos OS Release 20.2R1-S1 on the MX-Series, EX3400, EX4300, QFX5100, and QFX5200 devices, ZTP supports the DHCPv6 client. During the bootstrap process, the device first uses the DHCPv4 client to request for information regarding image and configuration file from the DHCP server. The device checks the DHCPv4 bindings sequentially. If there is a failure with one of the DHCPv4 bindings, the device will continue to check for bindings until provisioning is successful. If there are no DHCPv4 bindings, however, the device will check for DHCPv6 bindings and follow the same process as for DHCPv4 until the device can be provisioned successfully. The DHCP server uses DHCPv6 options 59 and 17 and applicable sub-options to exchange ZTP-related information between itself and the DHCP client.

20.2R1

Starting in Junos OS Release 20.2R1 on SRX300, SRX320, SRX340, SRX345, SRX550 HM, and SRX1500 devices, you can use Zero Touch Provisioning with DHCP options or the phone-home client to provision your device.

20.1R1EVO

Starting in Junos OS Evolved Release 20.1R1 on PTX10003 devices, Zero Touch Provisioning (ZTP) dynamically detects the port speed of WAN interfaces and uses this information to create ZTP server ports with the same speed.

20.1R1EVO

Starting in Junos OS Evolved Release 20.1R1, PTX10008 devices support automation of the device configuration and software upgrade over the management interface of Routing Engine 0 (RE0).

453

19.4R1

Starting in Junos OS Release 19.4R1, ZTP can automate the provisioning of the device configuration and software image on Juniper Route Reflector (JRR). ZTP supports self image upgrades and automatic configuration updates using ZTP DHCP options. In this release, ZTP supports revenue ports em2 thru em9, in addition to management port em0 which is supported in Junos OS Releases before 19.4R1.

19.3R1Evo

Starting in Junos OS Evolved Release 19.3R1, on QFX5220-128C device, in Zero Touch Provisioning (ZTP), you can use either WAN interfaces or management interfaces, to automatically download and install the appropriate software and the configuration file on your device during the bootstrap process.

19.3R1

Starting in Junos OS Release 19.3R1, you can use either WAN interfaces or management interfaces, to automatically download and install the appropriate software and the configuration file on your router during the ZTP bootstrap process.

19.2R1

Starting in Junos OS Release 19.2R1, ZTP can automate the provisioning of the device configuration and software image on management interface emo for ACX5448 switches.

19.1-Evo

Starting in Junos OS Evolved Release 19.1R1, ZTP can automate the provisioning of the device configuration and software image on the management interface for QFX5220 and PTX10003 devices.

19.1-Evo

Starting in Junos OS Evolved Release 19.1R1, to monitor zero touch provisioning on Junos OS Evolved, use the show system ztp command.

18.3R1

Starting in Junos OS Release 18.3R1, ZTP, which automates the provisioning of the device configuration and software image with minimal manual intervention, is supported on MX Series VM hosts.

18.2R1

Starting in Junos OS Release 18.2R1, ZTP can automate the provisioning of the device configuration and software image on VM host platforms that use PTX5000, PTX3000, PTX10008, PTX10016, PTX10002-60C routers.

18.2R1

Starting in Junos OS Release 18.2R1, ZTP can automate the provisioning of the device configuration and software image on VM host platforms that use QFX10008 and QFX10016 switches.

18.1R1

Starting in Junos OS Release 18.1R1, ZTP can automate the provisioning of the device configuration and software image on VM host platforms that use QFX10002-60C switches.

17.2R1

Starting in Junos OS Release 17.2R1, ZTP can automate the provisioning of the device configuration and software image on VM host platforms that use PTX1000 routers.

454

16.1R1 12.2

Starting in Junos OS Release 16.1R1, you can provision supported devices by using either a script to be executed or a configuration file to be loaded
Starting in Junos OS Release 12.2, you can use the console and operational commands to monitor Zero Touch Provisioning.

9 CHAPTER
Phone-Home Client
Obtaining Configurations and Software Image Without User Intervention Using Phone-Home Client | 456 Deploying the Phone-home Client and Zero Touch Provisioning on vSRX | 460 Provision a Virtual Chassis Using the Phone-Home Client | 463

456
Obtaining Configurations and Software Image Without User Intervention Using Phone-Home Client
IN THIS SECTION Prerequisites | 456 Understanding the Phone-Home Client | 457 Understanding the Redirect Server Configuration | 457 Understanding Interoperability Between the Phone-Home Client and DHCP-Based ZTP | 457 Understanding the Phone-Home Client Process | 458 Understanding the Configuration File Format for the Phone-Home Client | 459 Understanding Pre-Configuration and Post-Configuration Scripts | 459 Verifying that the Phone-Home Client Downloaded the Configuration and Software Image | 459
The phone-home client (PHC) enables the device or VM instance to securely obtain bootstrapping data, such as a configuration or software image, with no user intervention other than having to physically connect the device or VM instance to the network.
Prerequisites
PHC depends on the following software and utilities to operate: · Connectivity to redirect server and phone-home server (PHS) · DHCP client
NOTE: DHCP-based ZTP is not supported on vSRX.
· SLAX support for configuration commits

457
· Python support · Curl support · Factory default configuration · Mechanism to retrieve device serial number · SHA1/MD5 utilities to verify software image · Basic utilities like GREP and AWK
Understanding the Phone-Home Client
PHC enables the device or VM instance to securely obtain bootstrapping data, such as a configuration or software image, with no user intervention other than having to physically connect the device to the network. When the device or VM instance first boots, PHC connects to a redirect server, which then redirects to PHS to get the configuration or software image. Similar to DHCP-based ZTP, the device or VM instance must be in factory default state in order for PHC to provision the device. If the device is not in factory default state, you can issue the request system zeroize command to bring the device back to the factory default state.
Understanding the Redirect Server Configuration
By default, the factory default configuration includes the redirect server URL, which is https:// redirect.juniper.net.
Understanding Interoperability Between the Phone-Home Client and DHCP-Based ZTP
To avoid conflicts between these two provisioning methods, the following steps are taken when the device or VM instance boots up:
NOTE: DHCP-based ZTP is not supported on vSRX.

458
NOTE: Provisioning does not start if the device is not in factory default mode. If the device is not in factory default mode, issue the request system zeroize command.
NOTE: The request system zeroize command is not supported on vSRX.
1. If the DHCP client receives either partial or complete DHCP options, PHC is terminated, and DHCPbased ZTP attempts to provision the device until it is successful.
2. If the DHCP client does not receive DHCP options, PHC attempts to provision the device until it is successful. If PHC fails to connect to the redirect server, however, DHCP-based ZTP attempts to provision the device. Both provisioning methods attempt to provision the device until one method is successful.
Understanding the Phone-Home Client Process
The following steps take place when PHC is launched: 1. PHC connects to the redirect server. 2. The device or VM Instance downloads and installs the software image from PHS.
If the software upgrade fails, the process starts over. 3. The device or VM instance reboots, and PHC validates the installed software image when the device
comes back online. 4. The device or VM instance downloads the configuration. 5. If a script (either pre-configuration script, post-configuration scripts, or both) was received as part of
the configuration, the following happens:
NOTE: PHC supports both Python and shell scripts.
a. The pre-configuration script is executed. b. The configuration received from the redirect server is committed. c. The post-configuration script is executed.

459
6. PHC sends a bootstrap-complete message to the PHS. 7. PHC cleans up the downloaded resources. 8. The existing phone-home configuration, along with any supporting configuration, is overwritten by
the new configuration on the device or VM instance. 9. If any of the above steps fail, the phone-home process starts over again from the beginning, and a
bootstrap failure error message is sent to PHS.
Understanding the Configuration File Format for the Phone-Home Client
PHC supports XML as the file format for the configuration file. For example, the configuration file format looks like this:
<configuration> [ Configuration in XML format ] </configuration> Currently, only the merge and override CLI commands are supported on configurations received by the PHC.
Understanding Pre-Configuration and Post-Configuration Scripts
You can include pre-configuration and post-configuration scripts on PHS in addition to, or instead of, using the Junos OS CLI. Embed the scripts in base64 encoded format. PHC extracts the encoded scripts from the bootstrap information received from PHS, decodes, and then runs the decoded scripts at the appropriate stages of provisioning.
Verifying that the Phone-Home Client Downloaded the Configuration and Software Image
To verify the progress of the phone-home process, you can view the notification.xml file on PHS.

Release History Table Release
change-completed

460 Description

Deploying the Phone-home Client and Zero Touch Provisioning on vSRX

SUMMARY

IN THIS SECTION
Factory Default Configuration on vSRX | 460 Deploying ZTP on KVM | 461 Deploying ZTP on VMWare | 461 Deploying ZTP on Amazon Web Services, Google Cloud Platform, and Oracle CIoud Infrastructure | 462 Deploying ZTP on Microsoft Azure | 463

You can use the phone-home client and ZTP to provide a user-defined configuration file for the vSRX. The phone-home client and ZTP are supported on VMWare, KVM (Kernel-based Virtual Machine) hypervisors, and in various deployment environments, such as AWS (Amazon Web Service), GCP (Google Cloud Platform), OCI (Oracle Cloud Infrastructure, and Microsoft Azure.
Factory Default Configuration on vSRX
Here's the factory default configuration for the phone-home client:
set system services web-management http interface fxp0.0 set system services web-management https system-generated-certificate set system services web-management https interface fxp0.0 set system name-server 8.8.8.8 set system name-server 8.8.4.4

461
set system syslog file messages any any set system license autoupdate url https://ae1.juniper.net/junos/key_retrieval set system phone-home server https://redirect.juniper.net set system phone-home rfc-compliant set interfaces fxp0 unit 0 family inet dhcp
Deploying ZTP on KVM
To deploy ZTP on a KVM, set the entry name='version' to phone-home-true in the VM deployment XML file. For example:
<os> .... <smbios mode='sysinfo'/> </os> <sysinfo type='smbios'> <system> <entry name='version'>phonehome=true</entry> </system> </sysinfo>
Deploying ZTP on VMWare
To deploy ZTP on VMWare, enable the Open Virtualization Format (OVF) setting in the VMWare GUI, and set phone-home to true. 1. To enable OVF in the VMWare GUI, go to Edit Virtual Machine Setting | vApp Options | OVF setting :
OVF environment transparent | VMWare Tools: enable. 2. To enable the phone-home client in the VMWare GUI, go to Edit Virtual Machine Setting | vApp
Options | Properties | phone-home true .

462
Deploying ZTP on Amazon Web Services, Google Cloud Platform, and Oracle CIoud Infrastructure
To enable ZTP on Amazon Web Services, Google Cloud Platform, and Oracle CIoud Infrastructure, add the following phone-home client configuration in the CLOUD-INIT USER-DATA file:
system { name-server { 8.8.8.8; 8.8.4.4; } syslog { file messages { any any; } } services { ssh; web-management { http { interface fxp0.0; } https { system-generated-certificate; interface fxp0.0; } }
} license {
autoupdate { url https://ae1.juniper.net/junos/key_retrieval;
} } phone-home {
server https://redirect.juniper.net; rfc-compliant; } }
interfaces {

463
fxp0 { unit 0 { family inet { dhcp; } }
} }
Deploying ZTP on Microsoft Azure
To enable ZTP on Microsoft Azure, add the following phone-home client configuration in the write_files section of the CLOUD_INIT_CONFIG.JSON file:
{ "content": "configure\nset system name-server 8.8.8.8\nset system name-server
8.8.4.4\nset system phone-home server https://redirect.juniper.net\nset system phone-home rfc-compliant\nset
interfaces fxp0 unit 0 family inet dhcp\ncommit\n", "path": "/var/tmp/test_config" },
Provision a Virtual Chassis Using the Phone-Home Client

SUMMARY
Phone-home provisioning on a Virtual Chassis is a form of zero-touch provisioning (ZTP). The phonehome client (PHC) on the Virtual Chassis gets bootstrap information over the network from a phone-home server (PHS) and provisions the Virtual Chassis. The only user intervention required on the

IN THIS SECTION
Overview of Phone-Home Provisioning for a Virtual Chassis | 464
How To Enable Phone-Home Provisioning on a Virtual Chassis | 466

client side is to physically wire the Virtual Chassis members together and connect any port on the Virtual Chassis to the network.

464
Phone-Home Process on a Virtual Chassis | 467 Phone-Home Provisioning Status Notifications | 472 Verify Virtual Chassis Status After PhoneHome Provisioning | 475 Troubleshoot Phone-Home Provisioning Issues | 476

Overview of Phone-Home Provisioning for a Virtual Chassis
IN THIS SECTION Benefits of Phone-Home Provisioning on a Virtual Chassis | 465 Overview of the Phone-Home Provisioning Process on a Virtual Chassis | 465
With phone-home provisioning, a phone-home client (PHC) on a device initially provisions the device with a software image and configuration from a central network management data source called the phone-home server (PHS), requiring little or no user intervention at the remote site. A Virtual Chassis consists of a set of devices interconnected together using ports called Virtual Chassis ports (VCPs). You configure and manage the Virtual Chassis as a single device. Starting with Junos OS Release 20.3R1, we've made extensions to the phone-home provisioning process for a standalone device so it can also work on a Virtual Chassis. The PHC on a Virtual Chassis requires extra steps to coordinate and manage bootstrapping the member devices. The PHS is usually part of a network management system (NMS) that supports phone-home provisioning. Your network administrator enters the intended provisioning data that directs how devices and Virtual Chassis at remote sites should be set up. Your organization might have more than one PHS for redundancy. You can check Feature Explorer and search for phone-home to see the Virtual Chassis platforms that support phone-home provisioning.

465
Benefits of Phone-Home Provisioning on a Virtual Chassis
· Simplifies provisioning by launching the process automatically from the remote site, while securely obtaining bootstrap information from a central management system (the PHS) on your network or in the cloud.
· Doesn't require in-depth experience with the Junos OS CLI to coordinate the provisioning of multiple devices that make up a Virtual Chassis.
Overview of the Phone-Home Provisioning Process on a Virtual Chassis
On a Virtual Chassis that supports phone-home provisioning, for the process to work, you must set up the Virtual Chassis according to the requirements outlined in "How To Enable Phone-Home Provisioning on a Virtual Chassis". When the Virtual Chassis initially forms, the PHC process starts up automatically on the Virtual Chassis primary member and takes it from there: 1. The PHC connects to a PHS.
The PHC sends a provisioning request to a default redirect server URL, https://redirect.juniper.net, which redirects the request to an available PHS controlled by your network administrator or NMS. This step is the same as phone-home provisioning on a single device.
2. The PHS responds to the PHC provisioning request with the bootstrapping information, which includes the intended Virtual Chassis topology, software image, and configuration.
3. The PHC provisions the Virtual Chassis as specified by the PHS. Provisioning includes steps such as: · Validate the Virtual Chassis topology.
· Upgrade the software image sequentially on all of the member devices if needed.
· Run any pre-configuration or post-configuration staging scripts.
· Commit a new configuration on the Virtual Chassis.
The PHC sends status notifications to the PHS during the bootstrapping process, so the network administrator can verify the process completes successfully. The PHC also logs status locally in the system log files on the Virtual Chassis. If needed, you can view log files in the Junos OS CLI, and use Junos OS CLI commands to see Virtual Chassis and VCP connection status.

466
SEE ALSO Obtaining Configurations and Software Image Without User Intervention Using Phone-Home Client | 456 Zero Touch Provisioning | 406
How To Enable Phone-Home Provisioning on a Virtual Chassis
On a Virtual Chassis that supports phone-home provisioning, if you set up the Virtual Chassis according to the steps listed here, a phone-home client (PHC) process starts up automatically on the Virtual Chassis primary member. To enable phone-home provisioning on a Virtual Chassis: 1. Ensure that all Virtual Chassis members have the factory-default configuration and are powered off.
You can run the request system zeroize Junos OS CLI command to return a device to its factorydefault state.
NOTE: The Virtual Chassis can't be a mixed-mode Virtual Chassis because mixed mode is never set in the factory-default configuration.
2. Interconnect the Virtual Chassis members in a ring topology using only dedicated or defaultconfigured Virtual Chassis ports (VCPs) on each member device. Keep in mind that the PHC process works only if the Virtual Chassis is initially formed with VCPs that do not need to be explicitly configured (dedicated VCPs or ports that are VCPs in the factory-default configuration). See VCP Options by Switch Type for details on which ports are dedicated and defaultconfigured VCPs on different devices that support Virtual Chassis. See the hardware guide for the device to locate those ports on the device.
3. Connect the Virtual Chassis management interface (me0) or any network-facing port on any Virtual Chassis member to the network. After the PHC starts up on the Virtual Chassis, it uses this connection to access a PHS over the network and retrieve the bootstrapping information for this Virtual Chassis. For details about how the management interfaces work on a Virtual Chassis, see Understanding Global Management of a Virtual Chassis.
4. Power on the members of the Virtual Chassis.

467 Figure 24 on page 467 shows an example of a Virtual Chassis topology that can support phone-home provisioning--a four-member EX4300 Virtual Chassis cabled in a ring topology using default-configured VCPs (in this case, two of the 40-Gigabit Ethernet QSFP+ ports on each device). Figure 24: Sample Virtual Chassis That Can Support Phone-Home Provisioning
Usually you don't need to do anything else for the phone-home provisioning process to proceed and complete successfully. If you don't see successful completion status or the Virtual Chassis isn't up and operating as expected at the end of the process, read on to learn details about how the PHC works to help troubleshoot the issues. SEE ALSO
Understanding Virtual Chassis Components Virtual Chassis Overview for Switches
Phone-Home Process on a Virtual Chassis
IN THIS SECTION Startup and Request Provisioning Information from PHS | 468

468
Bootstrap Virtual Chassis Members | 471 Apply Scripts and New Configuration on the Virtual Chassis | 472 Provisioning Process Completion | 472
Phone-home provisioning on a Virtual Chassis is an extension of the standalone device phone-home support described in "Obtaining Configurations and Software Image Without User Intervention Using Phone-Home Client " on page 456. The PHC performs additional steps to manage bootstrapping the member devices that make up the Virtual Chassis.
The PHC process on a Virtual Chassis also requires the same software tools and utilities that standalone devices require for PHC to work. For example, the phone-home process needs DHCP client support to facilitate the network connection to the PHS in the same way as for a single device, and verifies a downloaded software image using the same checksum utilities. See "Prerequisites" on page 456 for a list of these general PHC requirements.
Phone-home provisioning starts up automatically on a Virtual Chassis on the client side after you've performed the tasks in "How To Enable Phone-Home Provisioning on a Virtual Chassis" on page 466 and if the Virtual Chassis meets the conditions described in Requirements for Phone-Home Provisioning to Work for a Virtual Chassis.
The provisioning process steps are grouped into the stages described in this section.
Startup and Request Provisioning Information from PHS
In the startup and request stage:
1. The Virtual Chassis boots up in factory-default or zeroized state as a nonprovisioned Virtual Chassis, and elects the initial primary and backup members. (See Understanding How the Primary in a Virtual Chassis Is Elected.)
2. The PHC starts up on the Virtual Chassis primary member, connects to the default redirect server (https://redirect.juniper.net) and sends a bootstrap request for the device. The redirect server redirects the PHC to an available PHS.
3. The PHC receives the response from PHS, starts to discover what Virtual Chassis members are connected, and prepares to provision the Virtual Chassis. The PHS response includes: · Virtual Chassis topology information--At a minimum, this part of the response indicates the device is expected to be part of a Virtual Chassis; otherwise, the PHC provisions only the primary member as a standalone device.
The response might additionally have full topology information, which includes the serial IDs of all the members the network administrator expects to be in the Virtual Chassis.

469
· Software image upgrade information--Includes a path to the intended software image and image verification details.
· Pre-configuration and post-configuration script information--Includes any staging scripts the network administrator needs the PHC to run before or after applying the new configuration.
· Configuration information--Includes the intended Virtual Chassis configuration and the method to apply that configuration.
The PHC must receive minimum required topology information to recognize it should provision a Virtual Chassis. Otherwise, the PHC defaults to provisioning only the primary member as a standalone device.
The PHC extensions for Virtual Chassis support two provisioning modes--the default mode and a more strict mode the PHS can specify in the response:
· By default, the PHC provisions any members it detects in the VC at the time it receives the PHS response. If the PHC encounters an error when bootstrapping a particular member, it moves on to bootstrap the next member or continues to the next provisioning step.
· If the PHS specifies the strict mode option in the response, the response must also include the full Virtual Chassis topology information. Provisioning succeeds only if the PHC finds and successfully bootstraps all of the same members listed in the PHS response. If the PHC doesn't detect all of the intended members or provisioning fails for any of them, the PHC restarts the process from the beginning to resend the provisioning request to another available PHS.
NOTE: The PHS can include the Virtual Chassis member serial IDs in the response in either mode. However, in the default mode, bootstrapping the Virtual Chassis can succeed even if the PHC doesn't detect all the members in the PHS response or if the PHS response doesn't include member details at all.
In this step, if the response includes full Virtual Chassis topology information and indicates to use strict provisioning mode, the PHC validates what it finds in the Virtual Chassis locally against the Virtual Chassis member information from the PHS response.
Table 24 on page 470 summarizes the actions the PHC takes starting in this step based on the type of topology information it receives in the PHS response, the provisioning mode, and the Virtual Chassis members that the PHS discovers locally.

470

Table 24: PHC Actions Based on Topology Information in PHS Response

Virtual Chassis Topology Information from PHS

Default Mode Actions

Strict Mode Actions If PHS Requests This Option

No topology information provided

Try to provision as standalone device.

N/A
(This mode can be specified only with full topology information)

Minimum required topology information for a Virtual Chassis

Discover members and proceed to provision Virtual Chassis with found members.

N/A
(This mode can be specified only with full topology information)

Full topology information for a Virtual Chassis, including serial IDs for all intended Virtual Chassis members

Discover members. If member list doesn't match PHS response, proceed anyway to provision Virtual Chassis with found members.

Bootstrap intended Virtual Chassis members from PHS response. Detect members; if all expected members are present and up, provisioning succeeds.

Otherwise retry to bootstrap and detect members that failed the process.

After member detection timeout with failure to detect all expected members, report error and restart process contacting another PHS to rerequest provisioning.

4. If the PHC proceeds to provision the devices in the Virtual Chassis, at this point the PHC commits some temporary changes to the Virtual Chassis configuration to enable smooth bootstrapping of all VC members.
For example, the PHC makes sure the Virtual Chassis primary and backup member roles don't change while the PHC is upgrading the software image on all the members.

471
Bootstrap Virtual Chassis Members
In this stage, the PHC bootstraps the Virtual Chassis, which includes installing the software image on and rebooting all of the members.
1. The PHC on the primary member compares the bootstrap information in the PHS response with what's on the Virtual Chassis to see if it needs to upgrade the software image. If the versions match, the PHC skips the remaing steps in this stage.
2. If the PHC needs to upgrade the software image, the PHC uses the bootstrap information in the PHS response (image filename and checksum information) to download and validate the image. If the download operation fails, the PHC retries until it succeeds. (This behavior is the same for standalone device or Virtual Chassis phone-home provisioning.)
3. The PHC proceeds to install and reboot the Virtual Chassis members based on the member roles as follows in this order: a. Linecard members--Installs the image on the linecard role members sequentially (in member ID order), and then reboots them all at the same time.
b. Backup member--Installs the image on the backup member and reboots it.
c. Primary member--Installs the image on the primary member, synchronizes the current PHC Virtual Chassis bootstrap state to the backup member, and triggers the primary member to reboot.
As the upgraded members boot up, the PHC checks that they are up and running again. This action is called member detection in log messages and status notifications. If the PHC fails to detect a member within a default member detection timeout, the PHC notifies the PHS of the error. See "Startup and Request Provisioning Information from PHS" on page 468 for the actions the PHC takes by default or if the PHS specified strict provisioning. 4. While the old primary member is rebooting, the original primary isn't available, so the Virtual Chassis switches primary role to the backup member. The Virtual Chassis also elects a new backup member at this time. 5. The PHC starts up on the new primary member (the original backup member) and resumes the Virtual Chassis bootstrap procedure from the PHC state inherited from the old primary. When the old primary finishes booting and rejoins the Virtual Chassis, it is initially in linecard role but then assumes the backup role to the new primary member. 6. When the PHC detects this last member is up and running, the provisioning process continues to the next stage to apply pre-configuration or post-configuration scripts and the new configuration to the Virtual Chassis.
NOTE: Avoid having pre-configuration scripts, post-configuration scripts, or the new configuration make any changes that might cause the Virtual Chassis to assign new member

472
roles or elect new primary and backup members during the provisioning process. Otherwise, provisioning might fail with unpredictable results.
Apply Scripts and New Configuration on the Virtual Chassis
The PHS response might include pre-configuration and post-configuration scripts the network administrator needs the PHC to run on the virtual Chassis before or after applying the new configuration. Phone-home provisioning supports Python or shell scripts and only XML format for the configuration. The PHS response also provides the Junos OS configuration for PHC to commit on the member devices in the Virtual Chassis. A Virtual Chassis operates as if it's a single device, so the PHC performs these steps on the Virtual Chassis as a whole: 1. Runs any specified pre-configuration scripts from PHS. 2. Applies and commits the new configuration from PHS. 3. Runs any specified post-configuration scripts from PHS.
Provisioning Process Completion
To complete the phone-home provisioning process, the PHC logs that the process completed successfully and sends a bootstrap completion notification to the PHS. The PHC doesn't run again unless you return the device or Virtual Chassis back to the factory-default state and have all other required conditions to trigger phone-home provisioning. See Requirements for Phone-Home Provisioning to Work for a Virtual Chassis for details.
Phone-Home Provisioning Status Notifications
The PHC logs status information locally in the system log (/var/log/messages) on the Virtual Chassis and sends status notifications to the PHS to report the progress of the provisioning process. These messages signal when the PHC completes the different provisioning stages and help you troubleshoot issues if the process doesn't complete successfully. See "Phone-Home Process on a Virtual Chassis" on page 467 for the steps the PHC performs in each stage of Virtual Chassis provisioning. Some PHC status messages are general and apply either for single device or Virtual Chassis provisioning. Notification messages that are specific to a particular Virtual Chassis member include: · The member ID

473

· The member's serial ID · The member's current role in the Virtual Chassis--Master, Backup, or Linecard Virtual Chassis member-specific notifications have the following format:

vc-member [memberID:serialID:role] message For example:

vc-member [2:AA1234567890:Backup] Successfully installed downloaded image. Initiating member reboot.

Phone-home process notifications consist of a notification type and message. Table 25 on page 473 lists notifications that are specific to the phone-home provisioning stages on a Virtual Chassis. Notification types with the vc-member keyword include Virtual Chassis member-specific information.
Table 25: PHC Notifications for Virtual Chassis Provisioning Steps

Notification Type

Notification Message

vc-member-image-installed

· Successfully installed downloaded image. Initiating image installation on next member.
· Successfully installed downloaded image. Initiating member reboot.

vc-member-image-installation-failed

· Image failed to install on the member. Giving up and trying a different phone-home-server.

vc-member-reboot-initiated

· Reboot initiated for Line Card members. Waiting for the members to come back up.

vc-member-upgrade-success

· No upgrade required. · Successfully upgraded. · Member detected and successfully upgraded.

474

Table 25: PHC Notifications for Virtual Chassis Provisioning Steps (Continued)

Notification Type

Notification Message

vc-member-upgrade-failed

· Upgrade failed !!! · Member detected but upgrade failed !!!

vc-member-detection-failed

· Did not come up post image upgrade
NOTE: This message means the PHC installed the new image and initiated a reboot of the Virtual Chassis member, but the PHC didn't detect that the member came up again within a prescribed member detection timeout.

vc-bootstrap-failed

· VC member bootstrap failure detected with Strict provisioning set.
NOTE: This message mean the PHC upgraded the expected linecard role members successfully, but after rebooting them, PHC didn't detect that all members came up again within a prescribed member detection timeout.
· VC with detection failed members and Strict provisioning set.
NOTE: This message means the PHC failed to detect one or more members after upgrading and rebooting all of them, and upon checking again, finds that one or more of them still failed to come up. With strict provisioning mode, PHC must successfully bootstrap all intended members for the provisioning process to signal successful completion.

475
Verify Virtual Chassis Status After Phone-Home Provisioning
IN THIS SECTION Purpose | 475 Action | 475

Purpose
Check the running status of the Virtual Chassis after PHC provisioning.
Action
Enter the show virtual-chassis command using the Junos OS CLI. For example:

{master:1} user@device> Virtual Chassis ID: xxxx.xxxx.xxxx Virtual Chassis Mode: Enabled

Member ID Status Serial No Interface 0 (FPC 0) Prsnt ... vcp-255/1/0

Model ex3400-24p

Mstr prio
128

vcp-255/1/1 1 (FPC 1) Prsnt ... vcp-255/1/0

ex3400-24p 128

vcp-255/1/1 2 (FPC 2) Prsnt ... vcp-255/1/0

ex3400-48p 128

vcp-255/1/1 Member ID for next new member: 3 (FPC 3)

Role

Mixed Route Neighbor List Mode Mode ID

Backup N VC 2

1

Master* N VC 0

2

Linecard N VC 0

1

476
Troubleshoot Phone-Home Provisioning Issues
To troubleshoot PHC problems during the provisioning process:
· Use utilities on the PHS side specific to your network management system to check device, Virtual Chassis, and connection status, or display phone-home process notifications (see "Phone-Home Provisioning Status Notifications" on page 472).
· Make sure the Virtual Chassis management or network interface is connected to the network and can connect to a PHS.
· If the PHS specified the strict mode option, verify the Virtual Chassis member serial IDs on the phone-home server side match the member devices you're interconnecting on the client side at the remote site.
· Look for error and status messages in the syslog file on the Virtual Chassis.
For example, syslog status messages can show that the ZTP client is trying to provision the device instead of or in addition to the PHC. Upon startup with the factory-default configuration on either a standalone device or a Virtual Chassis primary member, both the PHC and the DHCP-based ZTP process (see "Zero Touch Provisioning" on page 406) start running automatically. ZTP proceeds if DHCP ZTP options are configured, which can cause unexpected provisioning behavior because ZTP isn't supported for a Virtual Chassis. To trigger only phone-home provisioning, your DHCP system administrator can make sure the ZTP-specific options are not set on the DHCP server for devices intended to be in a Virtual Chassis under PHS management.
· Check the configuration on the Virtual Chassis after provisioning using the show configuration CLI command.
RELATED DOCUMENTATION Obtaining Configurations and Software Image Without User Intervention Using Phone-Home Client | 456 Understanding Virtual Chassis Components Zero Touch Provisioning | 406

10 CHAPTER
Automatic Installation of Configuration Files
Understanding Autoinstallation of Configuration Files | 478 Configuring Autoinstallation of Configuration Files | 489 Configuring Autoinstallation of Configuration Files on ACX Series | 505

478
Understanding Autoinstallation of Configuration Files
IN THIS SECTION Autoinstallation Overview | 478 Autoinstallation Process on Satellite Devices in a Junos Node Unifier Group | 486
Autoinstallation is an automated process and does not require any specific configuration on a device. To simplify the process, you can specify one or more interfaces, protocols, and configuration servers to be used for autoinstallation.
Autoinstallation Overview
IN THIS SECTION Automatic Installation of Configuration Files | 479 Supported Autoinstallation Interfaces and Protocols | 480 Typical Autoinstallation Process on a New Device | 480 Typical Uses for Autoinstallation | 484 Autoinstallation Configuration Files and IP Addresses | 484 Typical Autoinstallation Process on a New Switch | 484
If you are setting up many devices, autoinstallation can help automate the configuration process by loading configuration files onto new or existing devices automatically over the network. You can use either the J-Web configuration editor or the CLI configuration editor to configure a device for autoinstallation. Autoinstallation provides automatic configuration for a new device that you connect to the network and turn on, or for a device configured for autoinstallation. The autoinstallation process begins any time a

479
device is powered on and cannot locate a valid configuration file in the CompactFlash (CF) card. Typically, a configuration file is unavailable when a device is powered on for the first time, or if the configuration file is deleted from the CF card. The autoinstallation feature enables you to deploy multiple devices from a central location in the network. For the autoinstallation process to work, you must store one or more host-specific or default configuration files on a configuration server in the network and have a service available--typically Dynamic Host Configuration Protocol (DHCP)--to assign an IP address to the device. Autoinstallation takes place automatically when you connect an Ethernet or serial port on a new Juniper Networks device to the network and power on the device. To simplify the process, you can explicitly enable autoinstallation on a device and specify a configuration server, an autoinstallation interface, and a protocol for IP address acquisition. This section contains the following topics:
Automatic Installation of Configuration Files
On SRX Series devices, you can specify a remote server where configuration files are located. If a configuration file cannot be found on the device's CompactFlash card, the device automatically retrieves the configuration file from this remote server. For security purposes, you can encrypt these remote files using the DES cipher, and once they have been retrieved, the device decrypts them for use on the server. To encrypt the files, we recommend the OpenSSL tool. You can get the OpenSSL tool at http:// www.openssl.org/. To encrypt the file, use the following syntax:
% openssl enc -des -k passphrase -in original-file -out encrypted-file
· passphrase--Passphrase used to encrypt the configuration file. The passphrase should be the name of the file without the path information or file extension.
· original-file--Unencrypted configuration file.
· encrypted-file--Name of the encrypted configuration file.
For example, if you are encrypting the active configuration file juniper.conf.gz, the passphrase is juniper.conf. The openSSL syntax used to encrypt the file is:
% openssl enc -des -k juniper.conf -in juniper.conf.gz -out juniper.conf.gz.enc

480

Supported Autoinstallation Interfaces and Protocols

Before autoinstallation on a device can take place, the device must acquire an IP address. The protocol or protocols you choose for IP address acquisition determine the device interface to connect to the network for autoinstallation. The device detects the connected interface and requests an IP address with a protocol appropriate for the interface. Autoinstallation is supported over an Ethernet LAN interface or a serial LAN or WAN interface. Table 26 on page 480 lists the protocols that the device can use on these interfaces for IP address acquisition.
Table 26: Interfaces and Protocols for IP Address Acquisition During Autoinstallation

Interface and Encapsulation Type

Protocol for Autoinstallation

Ethernet LAN interface with High-Level Data Link Control (HDLC)

DHCP, BOOTP, or Reverse Address Resolution Protocol (RARP)

Serial WAN interface with HDLC

Serial Line Address Resolution Protocol (SLARP)

Serial WAN interface with Frame Relay

BOOTP

If the server with the autoinstallation configuration file is not on the same LAN segment as the new device, or if a specific device is required by the network, you must configure an intermediate device directly attached to the new device through which the new device can send Trivial File Transfer Protocol (TFTP), BOOTP, and Domain Name System (DNS) requests. In this case, you specify the IP address of the intermediate device as the location to receive TFTP requests for autoinstallation.
Typical Autoinstallation Process on a New Device
When a device is powered on for the first time, it performs the following autoinstallation tasks:
1. The new device sends out DHCP, BOOTP, RARP, or SLARP requests on each connected interface simultaneously to obtain an IP address.
If a DHCP server responds, it provides the device with some or all of the following information:
· An IP address and subnet mask for the autoinstallation interface.
· The location of the TFTP (typically), Hypertext Transfer Protocol (HTTP), or FTP server on which the configuration file is stored.
· The name of the configuration file to be requested from the TFTP server.

481
· The IP address or hostname of the TFTP server.
If the DHCP server provides only the hostname, a DNS server must be available on the network to resolve the name to an IP address.
· The IP address of an intermediate device if the configuration server is on a different LAN segment from the new device.
2. After the new device acquires an IP address, the autoinstallation process on the device attempts to download a configuration file in the following ways:
a. If the DHCP server specifies the host-specific configuration file (boot file) hostname.conf, the device uses that filename in the TFTP server request. (In the filename, hostname is the hostname of the new device.) The autoinstallation process on the new device makes three unicast TFTP requests for hostname.conf. If these attempts fail, the device broadcasts three requests to any available TFTP server for the file.
b. If the new device cannot locate hostname.conf, the autoinstallation process unicasts or broadcasts TFTP requests for a default device configuration file called network.conf, which contains hostname-to-IP address mapping information, to attempt to find its hostname.
c. If network.conf contains no hostname entry for the new device, the autoinstallation process sends out a DNS request and attempts to resolve the new device's IP address to a hostname.
d. If the new device can determine its hostname, it sends a TFTP request for the hostname.conf file.
e. If the new device is unable to map its IP address to a hostname, it sends TFTP requests for the default configuration file router.conf.
3. After the new device locates a configuration file on a TFTP server, autoinstallation downloads the file, installs the file on the device, and commits the configuration.
NOTE: · If you configure the DHCP server to provide only the TFTP server hostname, add an IP
address-to-hostname mapping entry for the TFTP server to the DNS database file on the DNS server in the network.
· If the new device is not on the same network segment as the DHCP server (or other device providing IP address resolution), configure an existing device as an intermediate to receive TFTP and DNS requests and forward them to the TFTP server and the DNS server. You must configure the LAN or serial interface on the intermediate device with the IP addresses of the hosts providing TFTP and DNS service. Connect this interface to the new device.

482
NOTE: Starting in Junos OS Release 15.1X49-D60 and in Junos OS Release 17.3R1, on SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX1500 devices, some of the factory-default configurations are changed. · The name-server statement, used to configure one or more Domain Name System (DNS)
name servers, is changed to 8.8.8.8 and 8.8.4.4. Previously, it was 208.67.222.222 and 208.67.220.220. · A new system service, NETCONF service over SSH, is introduced at the [edit system services] hierarchy:
edit system services netconf ssh
· The following configuration setting for HTTPS (secure management) access using the J-Web interface is changed. Now, there is no need to specify the interface details for J-Web management. With this configuration, you can manage the device from any interface through HTTPS.
edit system services web-management https interface [irb.0]
· A license autoupdate URL (https://ae1.juniper.net/junos/key_retrieval) is now supported under the [edit system] hierarchy:
license { autoupdate { url https://ae1.juniper.net/junos/key_retrieval; }
}
· A new system log configuration is introduced to configure system log messages to record all commands entered by users and all authentication or authorization attempts under the [edit system] hierarchy:
syslog { archive size 100k files 3; user * { any emergency;

483
} file messages {
any notice; authorization info; } file interactive-commands { interactive-commands any; } }
The above factory-default configurations are also applicable on SRX380 Series devices.
NOTE: On SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices, telnet and xnmclear-text are not part system services in factory-default configurations.
NOTE: In Junos OS Release 15.1X49-D40 and earlier, configuring autoinstallation using USB and Layer Ethernet switching was supported on the same interface. However, the command caused improper installation of the interface-related configurations. Layer 2 Ethernet switching is not supported on the same interface for SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices. The system autoinstallation interfaces <interface names> command and the set interface <interface names> unit 0 family ethernet-switching command cannot be configured on the same interface.
NOTE: USB auto-installation is not supported on SRX1500 devices and vSRX instances.
Autoinstallation is the automatic configuration of a device over the network from a preexisting configuration file that you create and store on a configuration server--typically a Trivial File Transfer Protocol (TFTP) server. You can use autoinstallation to configure new devices automatically and to deploy multiple devices from a central location in the network. You enable autoinstallation so that the switches in your network implement autoinstallation when they are powered on. To configure autoinstallation, you specify a configuration server, an autoinstallation interface, and a protocol for IP address acquisition.

484
NOTE: The QFX5200 switches only work with HTTP for autoinstallation. TFTP and FTP protocols are not supported.
Typical Uses for Autoinstallation
Typical uses for autoinstallation of the software include: · To deploy and update multiple devices from a central location in the network. · To update a device--Autoinstallation occurs when a device that has been manually configured for
autoinstallation is powered on.
Autoinstallation Configuration Files and IP Addresses
For the autoinstallation process to work, you must store one or more host-specific or default configuration files on a configuration server in the network and have a service available--typically Dynamic Host Configuration Protocol (DHCP)--to assign an IP address to the switch. You can set up the following configuration files for autoinstallation on the switch: · network.conf--Default configuration file for autoinstallation, in which you specify IP addresses and
associated hostnames for devices on the network. · switch.conf--Default configuration file for autoinstallation with a minimum configuration sufficient
for you to telnet to the device and configure it manually. · hostname.conf--Host-specific configuration file for autoinstallation on a device that contains all the
configuration information necessary for the switch. In the filename, hostname is replaced with the hostname assigned to the switch. If the server with the autoinstallation configuration file is not on the same LAN segment as the new device, or if a specific device is required by the network, you must configure an intermediate device directly attached to the new switch, through which the new switch can send TFTP, Boot Protocol (BOOTP), and Domain Name System (DNS) requests. In this case, you specify the IP address of the intermediate device as the location to receive TFTP requests for autoinstallation.
Typical Autoinstallation Process on a New Switch
When the switch configured for autoinstallation is powered on, it performs the following autoinstallation tasks:

485
1. The switch sends out DHCP or BOOTP requests on each connected interface simultaneously to obtain an IP address.
If a DHCP server responds to these requests, it provides the switch with some or all of the following information:
· An IP address and subnet mask for the autoinstallation interface.
· The location of the (typically) TFTP server, Hypertext Transfer Protocol (HTTP) server, or FTP server on which the configuration file is stored.
· The name of the configuration file to be requested from the TFTP server.
· The IP address or hostname of the TFTP server.
If the DHCP server provides the server's hostname, a DNS server must be available on the network to resolve the name to an IP address.
· The IP address of an intermediate device if the configuration server is on a different LAN segment from the switch.
2. After the switch acquires an IP address, the autoinstallation process on the switch attempts to download a configuration file in the following ways:
a. If the DHCP server specifies the host-specific configuration file hostname.conf, the switch uses that filename in the TFTP server request. The autoinstallation process on the new switch makes three unicast TFTP requests for hostname.conf. If these attempts fail, the switch broadcasts three requests to any available TFTP server for the file.
b. If the switch does not locate a hostname.conf file, the autoinstallation process sends three unicast TFTP requests for a network.conf file that contains the switch's hostname-to-IP-address mapping information. If these attempts fail, the switch broadcasts three requests to any available TFTP server for the file.
c. If the switch fails to find a network.conf file that contains a hostname entry for the switch, the autoinstallation process sends out a DNS request and attempts to resolve the switch's IP address to a hostname.
d. If the switch determines its hostname, it sends a TFTP request for the hostname.conf file.
e. If the switch is unable to map its IP address to a hostname, it sends TFTP requests for the default configuration file switch.conf. The TFTP request procedure is the same as for the network.conf file.
3. After the switch locates a configuration file on a TFTP server, the autoinstallation process downloads the file, installs the file on the switch, and commits the configuration.

486
NOTE: Please refer to the product Data Sheets for details, or contact your Juniper Account Team or Juniper Partner. Please refer to the Juniper Licensing Guide for general information about License Management.
Autoinstallation Process on Satellite Devices in a Junos Node Unifier Group
IN THIS SECTION Supported Autoinstallation Interfaces and Protocols | 486 Typical Autoinstallation Process on a New Router | 487
Autoinstallation provides automatic configuration for a new router that you connect to the network and power on, or for a router configured for autoinstallation. The autoinstallation process begins any time a router is powered on and cannot locate a valid configuration file in the CompactFlash card. Typically, a configuration file is unavailable when a router is powered on for the first time, or if the configuration file is deleted from the CompactFlash card. The autoinstallation feature enables you to deploy multiple routers from a central location in the network. For the autoinstallation process to work, you must store one or more host-specific or default configuration files on a configuration server in the network and have a service available--typically Dynamic Host Configuration Protocol (DHCP)--to assign an IP address to the router. Autoinstallation takes place automatically when you connect an Ethernet interface on a new Juniper Networks router to the network and power on the router. To simplify the process, you can explicitly enable autoinstallation on a router and specify a configuration server, an autoinstallation interface, and a protocol for IP address acquisition. This topic describes:
Supported Autoinstallation Interfaces and Protocols
Before autoinstallation on a router can take place, the router must acquire an IP address or a USB key. The protocol or protocols you choose for IP address acquisition determine the router interface to connect to the network for autoinstallation. The router detects the connected interface and requests an

487
IP address with a protocol appropriate for the interface. Autoinstallation is supported over an Ethernet LAN interface. For IP address acquisition, the JNU satellite router uses DHCP, BOOTP, or Reverse Address Resolution Protocol (RARP) on an Ethernet LAN interface.
If the server with the autoinstallation configuration file is not on the same LAN segment as the new router, or if a specific router is required by the network, you must configure an intermediate router directly attached to the new router, through which the new router can send HTTP, FTP, Trivial File Transfer Protocol (TFTP), BOOTP, and Domain Name System (DNS) requests. In this case, you specify the IP address of the intermediate router as the location to receive HTTP, FTP, or TFTP requests for autoinstallation.
Typical Autoinstallation Process on a New Router
When a router is powered on for the first time, it performs the following autoinstallation tasks:
1. The new router sends out DHCP, BOOTP, or RARP requests on each connected interface simultaneously to obtain an IP address.
If a DHCP server responds, it provides the router with some or all of the following information:
· An IP address and subnet mask for the autoinstallation interface.
· The location of the TFTP (typically), HTTP, or FTP server on which the configuration file is stored.
· The name of the configuration file to be requested from the HTTP, FTP, or TFTP server.
· The IP address or hostname of the HTTP, FTP, or TFTP server.
If the DHCP server provides only the hostname, a DNS server must be available on the network to resolve the name to an IP address.
· The IP address of an intermediate router if the configuration server is on a different LAN segment from the new router.
2. After the new router acquires an IP address, the autoinstallation process on the router attempts to download a configuration file in the following ways:
a. If the configuration file is specified as a URL, the router fetches the configuration file from the URL by using HTTP, FTP, or TFTP, depending on the protocol specified in the URL.
b. If the DHCP server specifies the host-specific configuration file (boot file) hostname.conf, the router uses that filename in the TFTP server request. (In the filename, hostname is the hostname of the new router.) The autoinstallation process on the new router makes three unicast TFTP requests for hostname.conf. If these attempts fail, the router broadcasts three requests to any available TFTP server for the file.

488
c. If the new router cannot locate hostname.conf, the autoinstallation process unicasts or broadcasts TFTP requests for a default router configuration file called network.conf, which contains hostname-to-IP address mapping information, to attempt to find its hostname.
d. If network.conf contains no hostname entry for the new router, the autoinstallation process sends out a DNS request and attempts to resolve the new router's IP address to a hostname.
e. If the new router can determine its hostname, it sends a TFTP request for the hostname.conf file.
f. If the new router is unable to map its IP address to a hostname, it sends TFTP requests for the default configuration file router.conf.
3. After the new router locates a configuration file on a TFTP server, the autoinstallation process downloads the file, installs the file on the router, and commits the configuration.
In a Junos Node Unifier (JNU) group that contains an MX Series router as a controller that manages satellite devices, such as EX Series Ethernet Switches, QFX Series devices, and ACX Series Universal Metro Routers, the autoinstallation functionality is supported for the satellite devices. JNU has an autoinstallation mechanism that enables a satellite device to configure itself out-of-the-box with no manual intervention, using the configuration available either on the network or locally through a removable media, or using a combination of both. This autoinstallation method is also called the zerotouch facility.
The zero-touch configuration delivers the following benefits:
· The router can be sent from the warehouse to the deployment site without any preconfiguration steps.
· The procedure required to deploy the device at the cell site is simplified, resulting in reduced operational and administrative costs.
· You can roll out large numbers of these devices in a very short time.
The factory default setting is autoinstallation-enabled. After you make the first configuration to the router, you can do either of the following:
· A JNU factory default file, jnu-factory.conf, is present in the /etc/config/ directory and contains the configuration to perform autoinstallation on satellite devices. The zero-touch configuration can be disabled by including the delete-after-commit statement at the [edit system autoinstallation] hierarchy level and committing the configuration. This way, the saved configuration is used the next time the system reboots.
· Alternatively, if the router must get the configuration from the server each time a system reboot occurs, the zero-touch configuration must not be changed (that is, you must not include the deleteafter-commit statement at the [edit system autoinstallation] hierarchy level and commit the settings).

489

SEE ALSO

autoinstallation (JNU Satellite Devices) | 544 delete-after-commit (JNU Satellites) | 555

Release History Table

Release

Description

15.1X49-D60

Starting in Junos OS Release 15.1X49-D60 and in Junos OS Release 17.3R1, on SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX1500 devices, some of the factory-default configurations are changed.

Configuring Autoinstallation of Configuration Files

IN THIS SECTION
Configuring Autoinstallation of Configuration Files (CLI Procedure) | 489 Example: Configuring Autoinstallation on SRX Series Devices | 492 Verifying Autoinstallation Status | 496 Autoinstalling a Configuration File from a Disk-on-Key USB Memory Stick onto an EX2200 or EX3300 Switch | 498 Configuring Autoinstallation on JNU Satellite Devices | 501 Verifying Autoinstallation on JNU Satellite Devices | 503

Autoinstallation is an automated process and does not require any specific configuration on a device. To simplify the process, you can specify one or more interfaces, protocols, and configuration servers to be used for autoinstallation.
Configuring Autoinstallation of Configuration Files (CLI Procedure)
Autoinstallation is the automatic configuration of a device over the network from a pre-existing configuration file that you create and store on a configuration server--typically a Trivial File Transfer

490
Protocol (TFTP) server. You can use autoinstallation to automatically deploy multiple devices from a central location in the network.
To specify autoinstallation to run when you power on a device already installed in your network, you can enable it by specifying one or more interfaces, protocols, and configuration servers to be used for autoinstallation.
· Have a service available--typically Dynamic Host Configuration Protocol (DHCP)--to assign an IP address to the device.
· Configure a DHCP server on your network to meet your network requirements. You can configure a switch to operate as a DHCP server.
· Create one of the following configuration files, and store it on a TFTP server (or HTTP server or FTP server) in the network:
· A host-specific file with the name hostname.conf for each device undergoing autoinstallation. Replace hostname with the name of a device. The hostname.conf file typically contains all the configuration information necessary for the device with this hostname.
· A default configuration file named device.conf with the minimum configuration necessary to enable you to telnet into the new device for further configuration.
· Physically attach the device to the network using a Gigabit Ethernet port.
· If you configure the DHCP server to provide only the TFTP server hostname, add an IP address-tohostname mapping entry for the TFTP server to the DNS database file on the Domain Name System (DNS) server in the network.
· If the device is not on the same network segment as the DHCP server (or other device providing IP address resolution), configure an existing device as an intermediate device to receive TFTP and DNS requests and forward them to the TFTP server and the DNS server. You must configure the LAN or serial interface on the intermediate device with the IP addresses of the hosts providing TFTP and DNS services. Connect this interface to the device.
· If you are using hostname.conf files for autoinstallation, you must also complete the following tasks:
· Configure the DHCP server to provide a hostname.conf filename to each device. Each device uses its hostname.conf filename to request a configuration file from the TFTP server. Copy the necessary hostname.conf configuration files to the TFTP server.
· Create a default configuration file named network.conf, and copy it to the TFTP server. This file contains IP-address-to-hostname mapping entries. If the DHCP server does not send a hostname.conf filename to a new device, the device uses network.conf to resolve its hostname based on its IP address.

491
Alternatively, you can add the IP-address-to-hostname mapping entry for the device to a DNS database file. The device uses the hostname to request a hostname.conf file from the TFTP server. Before you explicitly enable and configure autoinstallation on the device, perform these tasks as needed for your network's configuration: To configure autoinstallation: 1. Specify the URL address of one or more servers from which to obtain configuration files.
[edit system] user@host# set autoinstallation configuration-servers tftp://tftpconfig.example.com
NOTE: You can also use an FTP address, for example, ftp:// user:password@sftpconfig.example.com.
2. Configure one or more Ethernet interfaces to perform autoinstallation and one or two procurement protocols for each interface. The switch uses the protocols to send a request for an IP address for the interface:
[edit system] user@host# set autoinstallation interfaces ge-0/0/0 bootp
To verify autoinstallation, from the CLI, enter the show system autoinstallation status command.
user@host> show system autoinstallation status Autoinstallation status: Master state: Active Last committed file: None Configuration server of last committed file: 10.25.100.1 Interface:
Name: ge-0/0/0 State: Configuration Acquisition Acquired:
Address: 192.168.124.75 Hostname: host-ge-000 Hostname source: DNS Configuration filename: device-ge-000.conf

492
Configuration filename server: 10.25.100.3 Address acquisition:
Protocol: DHCP Client Acquired address: None Protocol: RARP Client Acquired address: None Interface: Name: ge-0/0/1 State: None Address acquisition: Protocol: DHCP Client Acquired address: None Protocol: RARP Client Acquired address: None
Example: Configuring Autoinstallation on SRX Series Devices
IN THIS SECTION Requirements | 492 Overview | 493 Configuration | 493 Verification | 496
This example shows how to configure a device for autoinstallation.
Requirements
Before you begin: · Configure a DHCP server on your network to meet your network requirements. You can configure a
device to operate as a DHCP server. · Create one of the following configuration files, and store it on a TFTP server in the network:

493
· A host-specific file with the name hostname.conf for each device undergoing autoinstallation. Replace hostname with the name of a device. The hostname.conf file typically contains all the configuration information necessary for the device with this hostname.
· A default configuration file named router.conf with the minimum configuration necessary to enable you to telnet into the new device for further configuration.
· Physically attach the device to the network using one or more of the following interface types: · Fast Ethernet · Gigabit Ethernet · Serial with HDLC encapsulation
Overview
No configuration is required on a device on which you are performing autoinstallation, because it is an automated process. However, to simplify the process, you can specify one or more interfaces, protocols, and configuration servers to be used for autoinstallation. The device uses these protocols to send a request for an IP address for the interface. · BOOTP--Sends requests over all interfaces. · RARP--Sends requests over Ethernet interfaces.
NOTE: Starting with Junos OS Release 15.1X49, you need to additionally configure the family inet under the interface using the set interfaces ge-0/0/X unit 0 family inet command for the SRX Series device to send dhcp requests out.
Configuration
IN THIS SECTION Procedure | 494

494
Procedure
CLI Quick Configuration To quickly configure this section of the example, copy the following commands, paste them into a text file, remove any line breaks, change any details necessary to match your network configuration, copy and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.
set system autoinstallation configuration-servers tftp://tftpconfig.sp.com set system autoinstallation interfaces ge-0/0/0 bootp rarp
Step-by-Step Procedure The following example requires you to navigate various levels in the configuration hierarchy. For instructions on how to do that, see Using the CLI Editor in Configuration Mode. To configure a device for autoinstallation: 1. Enable autoinstallation and specify the URL address of one or more servers from which to obtain
configuration files.
[edit system] user@host# set autoinstallation configuration-servers tftp://tftpconfig.sp.com
NOTE: You can also use an FTP address, for example, ftp://user:password@sftpconfig.sp.com.
2. Configure one or more Ethernet or serial interfaces to perform autoinstallation, and configure one or two procurement protocols for each interface.
[edit system] user@host# set autoinstallation interfaces ge-0/0/0 bootp rarp

495
Results
From configuration mode, confirm your configuration by entering the show system autoinstallation status command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it.
[edit] user@host# show system autoinstallation status
Autoinstallation status: Master state: Active Last committed file: None Configuration server of last committed file: 10.25.100.1 Interface:
Name: ge-0/0/0 State: Configuration Acquisition Acquired:
Address: 192.168.124.75 Hostname: host-ge-000 Hostname source: DNS Configuration filename: router-ge-000.conf Configuration filename server: 10.25.100.3 Address acquisition: Protocol: BOOTP Client Acquired address: None Protocol: RARP Client Acquired address: None
If you are done configuring the device, enter commit from configuration mode.
NOTE: When there is a user-specified configuration for a particular interface, delete the factory default for that interface. Having two configurations for the same device might lead to errors. For example, if PPP encapsulation is set on a T1 interface through user configuration while the factory default configuration configures CISCO HLDC on the same interface, then the interface might not come up and the following error is logged in the message file: "DCD_CONFIG_WRITE_FAILED failed."

496
Verification
IN THIS SECTION Verifying Autoinstallation | 496
Confirm that the configuration is working properly. Verifying Autoinstallation Purpose Verify that the device has been configured for autoinstallation. Action From operational mode, enter the show system autoinstallation status command. The output shows the settings configured for autoinstallation. Verify that the values displayed are correct for the device when it is deployed on the network.
Verifying Autoinstallation Status
IN THIS SECTION Purpose | 496 Action | 497 Meaning | 497
Purpose
Display the status of the autoinstallation feature.

497
Action
From the CLI, enter the show system autoinstallation status command.
Sample Output
command-name
user@switch> show system autoinstallation status Autoinstallation status: Master state: Active Last committed file: None Configuration server of last committed file: 10.25.100.1 Interface:
Name: ge-0/0/0 State: Configuration Acquisition Acquired:
Address: 192.168.124.75 Hostname: host-ge-000 Hostname source: DNS Configuration filename: switch-ge-000.conf Configuration filename server: 10.25.100.3 Address acquisition: Protocol: DHCP Client Acquired address: None Protocol: RARP Client Acquired address: None Interface: Name: ge-0/0/1 State: None Address acquisition: Protocol: DHCP Client Acquired address: None Protocol: RARP Client Acquired address: None
Meaning
The output shows the settings configured for autoinstallation. Verify that the values displayed are correct for the switch when it is deployed on the network.

498
Autoinstalling a Configuration File from a Disk-on-Key USB Memory Stick onto an EX2200 or EX3300 Switch
If you have a new EX2200 or EX3300 switch, you can use a Disk-on-Key USB memory stick ("USB key") to configure the switch, using either a text configuration file or an XML configuration file. Before you begin this task, ensure you have the following items: · A management device (PC or laptop).
· A Junos Space platform to generate a valid XML file (if you will be installing the XML configuration file).
· A Disk-on-Key device with one of the following 16-bit or 32-bit FAT file systems: · DOS 3.0+ 16-bit FAT (up to 32 MB)
· DOS 3.31+ 16-bit FAT (more than 32 MB)
· FAT32
· FAT32, LBA-mapped
· 16-bit FAT, LBA-mapped
· An EX2200 or EX3300 switch with the factory configuration. If other Junos OS configuration files exist on the switch, the switch cannot read the juniper-config.txt or juniper-config.xml file from the Disk-on-Key device.
NOTE: The USB-based autoinstallation process overrides the network-based autoinstallation process. If the switch detects a Disk-on-Key device containing a valid configuration file during autoinstallation, it configures the switch by using the configuration file on the Disk-on-Key device instead of fetching the configuration from the network. If both juniper-config.txt and juniper-config.xml files are on the Disk-on-Key device, the switch uses the text (txt) file.
To configure the switch by using a Disk-on-Key device that contains the configuration file in text format: 1. Using a text editor on the PC or laptop, create the configuration file, named juniper-config.txt, as a
sequence of configuration commands (set commands). To reuse the configuration from another switch, save the configuration in configuration mode as a sequence of configuration commands on the switch using the show | display set | save filename command and then copying the file to the PC or switch as juniper-config.txt.

499
NOTE: Ensure that the first line in the juniper-config.txt is edit and that the last line in the file is commit and-quit.
2. Copy the juniper-config.txt file to the Disk-on-Key device. 3. Plug the Disk-on-Key device into the USB port on the switch. 4. Power on the switch. 5. Observe the LEDs on the Disk-on-Key device, and wait as the switch starts and then accesses the
Disk-on-Key device. The switch reads the juniper-config.txt file from the Disk-on-Key device and commits the configuration.
NOTE: Before you remove the Disk-on-Key device from the switch, ensure that the configuration has been applied to the switch. You can issue the show configuration operational mode command on the switch to see the configuration.
Then remove the Disk-on-Key device from the switch. The configuration of the switch is complete. To configure the switch by using a Disk-on-Key device that contains the configuration file in XML format: 1. Power on the switch. 2. Configure the switch to use autoinstallation: a. Load the factory default configuration:
[edit] user@switch# load factory-default
b. Set the switch for autoinstallation:
[edit] user@switch# set system autoinstallation delete-upon-commit

500
c. Set the root authentication password:
[edit] user@switch# set system root-authentication plain-text-password
d. Commit the changes:
[edit] user@switch# commit
3. Power off the switch. 4. Using the Junos Space platform, create a valid configuration file in XML format, and name it juniper-
config.xml. 5. Copy the juniper-config.xml file to the Disk-on-Key device. 6. Plug the Disk-on-Key device into the USB port on the switch. 7. Power on the switch. 8. Observe the LEDs on the Disk-on-Key device, and wait as the switch starts and then accesses the
Disk-on-Key device. The switch reads the juniper-config.xml file from the Disk-on-Key device and commits the configuration.
NOTE: Before you remove the Disk-on-Key device from the switch, ensure that the configuration has been applied to the switch . You can issue the show configuration operational mode command on the switch to see the configuration.
Then remove the Disk-on-Key device from the switch. The configuration of the switch is complete.
SEE ALSO show system autoinstallation status Installing Software on EX Series Switches

501
Configuring Autoinstallation on JNU Satellite Devices
No configuration is required on a device on which you are performing autoinstallation because it is an automated process. However, to simplify the process, you can specify one or more interfaces, protocols, and configuration servers to be used for autoinstallation. In this scenario, satellite devices, such as EX Series Ethernet Switches, QFX Series devices, and ACX Series Universal Metro Routers, that are managed by the controller are considered. To configure autoinstallation: 1. Load the JNU factory-default configuration file on the satellite device to enable the device to
function in JNU mode.
user@satellite# load override /etc/config/jnu-factory.conf
An override operation discards the current candidate configuration and loads the configuration in the specified filename or the one that you type at the terminal. When you use the override option and commit the configuration, all system processes reparse the configuration. 2. Specify the URL address of one or more servers from which to obtain configuration files:
[edit system] user@host# set autoinstallation configuration-servers tftp://tftpconfig.sp.com
NOTE: You can also use an HTTP or FTP address--for example, http:// user:password@httpconfig.sp.com or ftp://user:password@sftpconfig.sp.com.
3. Configure one or more Ethernet interfaces to perform autoinstallation and IP address acquisition protocols for each interface. The router uses the protocols to send a request for an IP address for the interface:
[edit system] user@host# set autoinstallation interfaces ge-0/0/0 bootp
4. Set the root password, entering a clear-text password that the system will encrypt, a password that is already encrypted, or an SSH public key string. Choose one of the following:

502
· To enter a clear-text password, use the following command:
[edit system] user@host# set root-authentication plain-text-password New password: type password here Retype new password: retype password here
· To enter a password that is already encrypted, use the following command:
[edit] root# set system root-authentication encrypted-password encrypted-password
· To enter an SSH public key, use the following command:
[edit] root# set system root-authentication ssh-rsa key
5. Save the Junos OS configuration changes, activate the configuration on the device, and exit configuration mode, using the commit-and-quit command.
[edit] user@host# commit-and-quit
When the satellite device reboots, it triggers the autoinstallation mechanism to retrieve its initial configuration and downloads the settings from the configuration file stored on a configuration server in the network. On the controller, you must enable the FTP service by using the set system services ftp command and save the configuration on the satellite device at the /var/jnu/ directory. The following configuration is generated on the satellite device as a result of the preceding procedure to configure autoinstallation:
system { autoinstallation { traceoptions { flags { all; } file autod; level all;

503
} delete-after-commit; /* After initial config, no need to keep */ interfaces { ge-* { bootp; } xe-* { bootp; } configuration-servers { "ftp://192.168.0.1/var/jnu/sat1.conf"; } }
} root-authentication {
encrypted-password "$ABC123";
} }
SEE ALSO autoinstallation (JNU Satellite Devices) | 544 delete-after-commit (JNU Satellites) | 555
Verifying Autoinstallation on JNU Satellite Devices
IN THIS SECTION Purpose | 504 Action | 504 Meaning | 505

504
Purpose
After you have configured autoinstallation, display the status of autoinstallation on a satellite device, such as an ACX Series router, an EX Series switch, or a QFX Series device, in a Junos Node Unifier (JNU) group that is managed by a controller, which is an MX Series router.
Action
From the CLI, enter the show system autoinstallation status command. The following example displays the autoinstallation settings of an ACX Series router that operates as a satellite in a JNU group.
Sample Output
command-name
user@host> show system autoinstallation status Autoinstallation status: Master state: Active Last committed file: None Configuration server of last committed file: 10.25.100.1 Interface: Name: ge-0/1/0 State: Configuration Acquisition Acquired: Address: 192.168.124.75 Hostname: host-ge-000 Hostname source: DNS Configuration filename: router-ge-000.conf Configuration filename server: 10.25.100.3 Address acquisition: Protocol: DHCP Client Acquired address: None Protocol: RARP Client Acquired address: None Interface: Name: ge-0/1/1 State: None Address acquisition: Protocol: DHCP Client Acquired address: None Protocol: RARP Client

505
Acquired address: None
Meaning
The output shows the settings configured for autoinstallation. Verify that the values displayed are correct for the router when it is deployed on the network.
SEE ALSO autoinstallation (JNU Satellite Devices) | 544 delete-after-commit (JNU Satellites) | 555 show system autoinstallation status | 808
Configuring Autoinstallation of Configuration Files on ACX Series
IN THIS SECTION ACX Series Autoinstallation Overview | 506 Before You Begin Autoinstallation on an ACX Series Universal Metro Router | 508 Autoinstallation Configuration of ACX Series Universal Metro Routers | 509 Verifying Autoinstallation on ACX Series Universal Metro Routers | 510 USB Autoinstallation on ACX Series Routers | 511 Autoinstallation on ACX Series Routers in Hybrid Mode Overview | 512 Prerequisites for Autoinstallation on ACX Series Routers in Hybrid Mode | 514 Autoinstallation Process on a New ACX Series Router in Hybrid Mode | 514 Configuring Autoinstallation of ACX Series Routers in Hybrid Mode | 517

506
Autoinstallation is an automated process and does not require any specific configuration on a device. To simplify the process, you can specify one or more interfaces, protocols, and configuration servers to be used for autoinstallation.
ACX Series Autoinstallation Overview
IN THIS SECTION Supported Autoinstallation Interfaces and Protocols | 506 Typical Autoinstallation Process on a New Router | 507
Autoinstallation provides automatic configuration for a new router that you connect to the network and turn on, or for a router configured for autoinstallation. The autoinstallation process begins anytime a router is powered on and cannot locate a valid configuration file in the CompactFlash (CF) card. Typically, a configuration file is unavailable when a router is powered on for the first time, or if the configuration file is deleted from the CF card. The autoinstallation feature enables you to deploy multiple routers from a central location in the network. For the autoinstallation process to work, you must store one or more host-specific or default configuration files on a configuration server in the network and have a service available--typically Dynamic Host Configuration Protocol (DHCP)--to assign an IP address to the router. Autoinstallation takes place automatically when you connect an Ethernet on a new Juniper Networks router to the network and power on the router. To simplify the process, you can explicitly enable autoinstallation on a router and specify a configuration server, an autoinstallation interface, and a protocol for IP address acquisition.
Supported Autoinstallation Interfaces and Protocols
Before autoinstallation on a router can take place, the router must acquire an IP address or a USB key. The protocol or protocols you choose for IP address acquisition determine the router interface to connect to the network for autoinstallation. The router detects the connected interface and requests an IP address with a protocol appropriate for the interface. Autoinstallation is supported over an Ethernet LAN interface. For IP address acquisition, the ACX Series router uses DHCP, BOOTP, or Reverse Address Resolution Protocol (RARP) on an Ethernet LAN interface. If the server with the autoinstallation configuration file is not on the same LAN segment as the new router, or if a specific router is required by the network, you must configure an intermediate router

507
directly attached to the new router, through which the new router can send HTTP, FTP, Trivial File Transfer Protocol (TFTP), BOOTP, and Domain Name System (DNS) requests. In this case, you specify the IP address of the intermediate router as the location to receive HTTP, FTP, or TFTP requests for autoinstallation.
Typical Autoinstallation Process on a New Router
When a router is powered on for the first time, it performs the following autoinstallation tasks:
1. The new router sends out DHCP, BOOTP, or RARP requests on each connected interface simultaneously to obtain an IP address.
If a DHCP server responds, it provides the router with some or all of the following information:
· An IP address and subnet mask for the autoinstallation interface.
· The location of the TFTP (typically), Hypertext Transfer Protocol (HTTP), or FTP server on which the configuration file is stored.
· The name of the configuration file to be requested from the HTTP, FTP, or TFTP server.
· The IP address or hostname of the HTTP, FTP, or TFTP server.
If the DHCP server provides only the hostname, a DNS server must be available on the network to resolve the name to an IP address.
· The IP address of an intermediate router if the configuration server is on a different LAN segment from the new router.
2. After the new router acquires an IP address, the autoinstallation process on the router attempts to download a configuration file in the following ways:
a. If the configuration file is specified as a URL, the router fetches the configuration file from the URL by using HTTP, FTP, or TFTP depending on the protocol specified in the URL.
b. If the DHCP server specifies the host-specific configuration file (boot file) hostname.conf, the router uses that filename in the TFTP server request. (In the filename, hostname is the hostname of the new router.) The autoinstallation process on the new router makes three unicast TFTP requests for hostname.conf. If these attempts fail, the router broadcasts three requests to any available TFTP server for the file.
c. If the new router cannot locate hostname.conf, the autoinstallation process unicasts or broadcasts TFTP requests for a default router configuration file called network.conf, which contains hostname-to-IP address mapping information, to attempt to find its hostname.
d. If network.conf contains no hostname entry for the new router, the autoinstallation process sends out a DNS request and attempts to resolve the new router's IP address to a hostname.

508
e. If the new router can determine its hostname, it sends a TFTP request for the hostname.conf file.
f. If the new router is unable to map its IP address to a hostname, it sends TFTP requests for the default configuration file router.conf.
3. After the new router locates a configuration file on a TFTP server, autoinstallation downloads the file, installs the file on the router, and commits the configuration.
Before You Begin Autoinstallation on an ACX Series Universal Metro Router
To configure a router for autoinstallation, complete the following tasks:
· Make sure you have a DHCP server on your network to meet your network requirements.
· Create one of the following configuration files and store it on an HTTP, FTP, or TFTP server in the network: · A host-specific file with the name hostname.conf for each router undergoing autoinstallation. Replace hostname with the name of a router. The hostname.conf file typically contains all the configuration information necessary for the router with this hostname.
· A default configuration file named router.conf with the minimum configuration necessary to enable you to telnet into the new router for further configuration.
· Physically attach the router to the network using a Gigabit Ethernet interface.
· If you configure the DHCP server to provide only the HTTP, FTP, or TFTP server hostname, add an IP address-to-hostname mapping entry for the HTTP, FTP, or TFTP server to the DNS database file on the DNS server in the network.
· If the new router is not on the same network segment as the DHCP server (or other router providing IP address resolution), configure an existing router as an intermediate to receive HTTP, FTP, or TFTP and DNS requests and forward them to the HTTP, FTP, or TFTP and DNS servers. You must configure the LAN on the intermediate router with the IP addresses of the hosts providing HTTP, FTP, or TFTP and DNS service. Connect this interface to the new router.
· If you are using hostname.conf files for autoinstallation of host-specific configuration files, you must also complete the following tasks: · Configure the DHCP server to provide a hostname.conf filename to each new router. Each router uses its hostname.conf filename to request a configuration file from the TFTP server. Copy the necessary hostname.conf configuration files to the TFTP server.

509
· Create a default configuration file named network.conf and copy it to the TFTP server. This file contains IP address-to-hostname mapping entries. If the DHCP server does not send a hostname.conf filename to a new router, the router uses network.conf to resolve its hostname based on its IP address. Alternatively, you can add the IP address-to-hostname mapping entry for the new router to a DNS database file. The router uses the hostname to request a hostname.conf file from the server.
Autoinstallation Configuration of ACX Series Universal Metro Routers
No configuration is required on a router on which you are performing autoinstallation because it is an automated process. However, to simplify the process, you can specify one or more interfaces, protocols, and configuration servers to be used for autoinstallation. To configure autoinstallation: 1. Specify the URL address of one or more servers from which to obtain configuration files.
[edit system] user@host# set autoinstallation configuration-servers tftp://tftpconfig.sp.com
NOTE: You can also use an HTTP or FTP address--for example, http:// user:password@httpconfig.sp.com or ftp://user:password@sftpconfig.sp.com.
2. Configure one or more Ethernet interfaces to perform autoinstallation and IP address acquisition protocols for each interface. The router uses the protocols to send a request for an IP address for the interface:
[edit system] user@host# set autoinstallation interfaces ge-0/0/0 bootp

510
Verifying Autoinstallation on ACX Series Universal Metro Routers
IN THIS SECTION Purpose | 510 Action | 510 Meaning | 511
Purpose
After you have configured autoinstallation, display the status of autoinstallation on an ACX Series router.
Action
From the CLI, enter the show system autoinstallation status command.
Sample Output
command-name
user@host> show system autoinstallation status Autoinstallation status: Master state: Active Last committed file: None Configuration server of last committed file: 10.25.100.1 Interface: Name: ge-0/1/0 State: Configuration Acquisition Acquired: Address: 192.168.124.75 Hostname: host-ge-000 Hostname source: DNS Configuration filename: router-ge-000.conf Configuration filename server: 10.25.100.3 Address acquisition: Protocol: DHCP Client

511
Acquired address: None Protocol: RARP Client Acquired address: None Interface: Name: ge-0/1/1 State: None Address acquisition: Protocol: DHCP Client Acquired address: None Protocol: RARP Client Acquired address: None
Meaning
The output shows the settings configured for autoinstallation. Verify that the values displayed are correct for the router when it is deployed on the network.
SEE ALSO autoinstallation show system autoinstallation status
USB Autoinstallation on ACX Series Routers
If you have a new ACX Series router, you can use a Disk-on-Key USB memory stick ("USB key") to configure the router. This configuration method has the following requirements: · A management device (PC or laptop). · A Disk-on-Key device with one of the following 16-bit or 32-bit file allocation table (FAT) file
systems: · DOS 3.0+ 16-bit FAT (up to 32 MB) · DOS 3.31+ 16-bit FAT (over 32 MB) · FAT32

512
· FAT32, LBA-mapped
· 16-bit FAT, LBA-mapped
· An ACX Series router with the factory configuration. If other Junos OS configuration files exist on the router, the router cannot read the juniper-config.txt file from the Disk-on-Key device.
NOTE: The USB-based autoinstallation process overrides the network-based autoinstallation process. If the ACX Series router detects a USB Disk-on-Key device containing a valid configuration file during autoinstallation, it configures the router using the configuration file on Disk-on-Key instead of fetching the configuration from the network.
To configure an ACX Series router using Disk-on-Key: 1. Using a text editor on a PC or laptop, create the configuration file, named juniper-config.txt, as a
sequence of configuration commands ("set" commands). To reuse configuration from another ACX Series router, the configuration can be saved in configuration mode as a sequence of configuration commands on the router using the "show | display set | save <filename>" command and then copying the <filename> to the PC or router as juniper-config.txt. 2. Copy the juniper-config.txt file to a Disk-on-Key device. 3. Plug the Disk-on-Key device into the USB port on the new ACX Series router. 4. Power on the router by pressing the POWER button on the front panel. Wait for the router to start and access the Disk-on-Key device (observe the LEDs on the Disk-on-Key device). The router reads the juniper-config.txt file from the Disk-on-Key device and commits the configuration. 5. Remove the Disk-on-Key device from the router. 6. The configuration of the router is complete.
Autoinstallation on ACX Series Routers in Hybrid Mode Overview
The ACX Series router has an autoinstallation mechanism that allows the router to configure itself outof-the-box with no manual intervention, using the configuration available either on the network, locally through a removable media, or a combination of both. Autoinstallation process delivers the following benefits: · The router can be sent from the warehouse to the deployment site without any pre-configuration
steps.

513
· The procedure required to deploy the device at the cell site is simplified, resulting in reduced operational and administrative costs.
· You can roll out large numbers of these devices in a very short time.
ACX Series routers support the retrieval of partial configuration from an external USB storage device plugged into the router's USB port during the autoinstallation process. This partial configuration in turn facilitates the network mode of autoinstallation to retrieve the complete configuration file from the network. This method is called hybrid mode of autoinstallation.
Autoinstallation process operates in three modes:
· USB mode--Autoinstallation obtains the required configuration from the configuration file saved in an external USB storage device plugged into the router.
· Network Mode--Autoinstallation triggers IP address acquisition mechanism (the router sends out DHCP or RARP requests on each connected interface simultaneously) to obtain an IP address. Once the router has an IP address, it sends a request to the specified configuration server and downloads and installs the configuration.
· Hybrid mode--Autoinstallation obtains partial configuration from an external USB storage device and uses that configuration to obtain the complete configuration file in network mode. This mode is a combination of USB mode and Network mode.
On the different ACX Series routers, autoinstallation is supported on the following Gigabit Ethernet (ge) and 10- Gigabit Ethernet (xe) interfaces:
· On ACX1000 routers, interfaces ge-0/1/0 through ge-0/1/7, and ge-0/2/0 through ge-0/2/3
· On ACX1100 routers, interfaces ge-0/0/0 through ge-0/0/7, and ge-0/1/0 through ge-0/1/3
· On ACX2000 routers, interfaces ge-0/1/0 through ge-0/1/7, ge-0/2/0 through ge-0/2/1, and xe-0/3/0 through xe-0/3/1
· On ACX2100 routers, interfaces ge-1/0/0 through ge-1/0/3, ge-1/1/0 through ge-1/1/3, ge-1/2/0 through ge-1/2/1, and xe-1/3/0 through xe-1/3/1
· On ACX2200 routers, interfaces ge-0/0/0 through ge-0/0/3, ge-0/1/0 through ge-0/1/3, ge-0/2/0 through ge-0/2/1, and xe-0/3/0 through xe-0/3/1
· On ACX4000 routers, interfaces ge-0/0/0 through ge-0/0/7, ge-0/1/0 through ge-0/1/1, ge-1/0/0 through ge-1/0/5, ge-1/1/0 through ge-1/1/5 , and xe-0/2/0 through xe-0/2/1

514
Prerequisites for Autoinstallation on ACX Series Routers in Hybrid Mode
Before you perform autoinstallation on a router in hybrid mode, complete the following tasks: Using a text editor on a PC or laptop, create the configuration file, named juniper-config.txt, as a sequence of configuration commands ("set" commands). To reuse configuration from another ACX Series router, the configuration can be saved in configuration mode as a sequence of configuration commands on the router using the "show | display set | save <filename>" command and then copying the <filename> to the PC or router as juniper-config.txt. You must copy the juniper-config.txt file to an external USB storage device. Plug the USB device into the USB port on the new ACX Series router. When you power on the router, the router first attempts to access the external USB storage device. The router reads the juniper-config.txt file from the external USB storage device and commits the configuration.
NOTE: For autoinstallation process to switch to the network mode, the continue-network-mode statement must be present in the autoinstallation stanza at the [edit system autoinstallation] hierarchy level of the juniper-config.txt configuration file. The presence of the continuenetwork-mode statement in the juniper-config.txt file causes the router to consider it as a partial configuration. Otherwise, if the continue-network-mode statement is not present in the juniperconfig.txt file, the router considers the configuration on the external USB storage device as the complete configuration and it will not switch to the network mode.
Perform all of the steps described in the Before You Begin Autoinstallation on an ACX Series Universal Metro Router section, which prepares the router for network-based autoinstallation.
Autoinstallation Process on a New ACX Series Router in Hybrid Mode
You can perform autoinstallation on a new ACX Series router in hybrid mode, which is a combination of the USB-based autoinstallation process and the network-based autoinstallation process. This configuration method has the following requirements: · A management device (PC or laptop). · An external USB storage device with one of the following 16-bit or 32-bit file allocation table (FAT)
file systems: · DOS 3.0+ 16-bit FAT (up to 32 MB) · DOS 3.31+ 16-bit FAT (over 32 MB)

515
· FAT32
· FAT32, LBA-mapped
· 16-bit FAT, LBA-mapped
BOOTP, RARP and DHCP are the supported protocols for acquisition of IP address of the router and TFTP, FTP, and HTTP are the supported protocols for downloading the configuration file from an external server URL on which the configuration file is stored.
The following operations occur during autoinstallation in hybrid mode on ACX Series routers:
1. When a new ACX Series router is powered on for the first time, the router performs the following autoinstallation tasks: The router boots the Junos OS image. The management process (mgd) is invoked and it determines whether a valid configuration exists on the router's Flash memory. If a valid configuration is not present on the router, it loads and commits the factory-default configuration.
2. If the factory-default configuration contains the autoinstallation configuration stanza at the [edit system] hierarchy level, the autoinstallation process is triggered.
3. The autoinstallation process detects whether an external USB storage device is connected to the router and examines whether the USB device contains a valid configuration file. If the USB storage device contains a configuration file named juniper-config.txt, the router reads the juniper-config.txt file and commits the configuration.
4. If the juniper-config.txt file on the external USB storage device contains continue-network-mode statement, the configuration is treated as partial configuration. The autoinstallation process uses this partial configuration to obtain the complete configuration file from a server on the network. At this stage, the router completes the USB mode of the autoinstallation procedure and switches to the network mode of the autoinstallation procedure.
NOTE: The continue-network-mode statement must be present in the autoinstallation stanza at the [edit system autoinstallation] hierarchy level of the juniper-config.txt file.
5. After acquiring the partial configuration from the juniper-config.txt file, the configuration discovery procedure is initiated. For all physical Ethernet interfaces that transition to the up state, the autoinstallation process verifies whether autoinstallation is configured on that Ethernet interface. The autoinstallation process starts IP address acquisition mechanism to obtain IP address of the server followed by the configuration file retrieval mechanism.
6. For the interfaces that take part in the autoinstallation process, the IPv4 address discovery procedure is triggered. The new ACX Series router sends out DHCP, or BOOTP, or RARP requests on each connected interface simultaneously to obtain an IP address. The interfaces statement in the

516
autoinstallation configuration stanza at the [edit system] hierarchy level in the factory-default configuration also specify the protocols to be used for IPv4 address discovery. If the interfaces statement is not configured, all the applicable protocols for an interface are used to send out requests on each connected Ethernet interface.
7. If an IPv4 address cannot be retrieved, the autoinstallation process starts the DHCP server on all participating interfaces (assigns static IP address in the form of 192.168.x.1 to allow a management station to connect to the router for manual configuration) and terminates the autoinstallation procedure.
8. If a DHCP server responds, it provides the router with some or all of the following information:
· An IP address and subnet mask for the autoinstallation interface.
· The location of the TFTP server on which the configuration file is stored.
· The name of the configuration file to be requested from the TFTP server.
· The IP address or hostname of the TFTP server.
· If the DHCP server provides configuration server hostname, a DNS server must be available on the network to resolve the name to an IP address.
· The IP address of an intermediate router if the configuration server is on a different LAN segment from the new router.
NOTE: To use HTTP or FTP server, you need to specify the URL of the configuration server under the [edit system autoinstallation configuration-servers] hierarchy level.
9. After an IPv4 address is retrieved for an interface, the interface is configured with that address and the autoinstallation process starts the configuration file discovery procedure. The autoinstallation process on the router attempts to download a configuration file in the following methods:
a. If the configuration file is specified as a URL, the router fetches the configuration file from the URL by using HTTP, FTP, or TFTP depending on the protocol specified in the URL.
b. If the DHCP server specifies the host-specific configuration file (either through file field option or boot file option or host name), the router uses that filename in the TFTP server request. In case of host name, the configuration filename is hostname.conf. The autoinstallation process on the new router makes unicast TFTP request for hostname.conf. If this attempt fails, the router broadcasts the request to any available TFTP server for the configuration file.
c. If the new router is unable locate the configuration file, the autoinstallation process unicasts or broadcasts TFTP requests for a default router configuration file called network.conf, which contains hostname-to-IP address mapping information, to attempt to find its hostname.

517
d. If network.conf contains no hostname entry for the new router, the autoinstallation process sends out a DNS request and attempts to resolve the new router's IP address to a hostname.
e. If the new router can determine its hostname, it sends a TFTP request for the hostname.conf file. f. If the new router is unable to map its IP address to a hostname, it sends TFTP requests for the
default configuration file router.conf.
NOTE: The autoinstallation process makes a maximum of three attempts to retrieve the configuration file by repeating the methods listed above (b to f). In case the autoinstallation process fails to retrieve the configuration file after three attempts, the autoinstallation process goes to start state.
g. After the new router locates a configuration file on a TFTP server, autoinstallation downloads the file, installs the file on the router, and commits the configuration.
Configuring Autoinstallation of ACX Series Routers in Hybrid Mode
To configure the router for autoinstallation in hybrid mode, perform the following tasks: Create a configuration file as juniper-config.txt. 1. Using a text editor on a PC or laptop, create the configuration file, named juniper-config.txt. This
configuration file must contain a sequence of configuration commands ("set" commands).
NOTE: To reuse a configuration from another ACX Series router, save the configuration in configuration mode as a sequence of configuration commands on the router using the "show | display set | save <filename>" command and then copying the <filename> to the PC or router as juniper-config.txt.
2. Include the continue-network-mode statement at the [edit system autoinstallation] hierarchy level in the juniper-config.txt configuration file. The presence of the continue-network-mode statement causes the router to consider it as a partial configuration and the autoinstallation process switches to network mode to retrieve the complete configuration from a network server.
[edit system] user@host# set autoinstallation continue-network-mode

518
3. Specify the URL address of one or more network servers from which to obtain the complete configuration.
[edit system] user@host# set autoinstallation configuration-servers tftp://username:password@tftpconfig.sp.com/ filename.conf
NOTE: You can also use an HTTP or FTP address--for example, http:// user:password@httpconfig.sp.com/filename.conf or ftp://user:password@sftpconfig.sp.com/ filename.conf.
4. Specify the root authentication password.
[edit system] user@host# set root-authentication encrypted-password "password"; 5. Configure one or more Ethernet interfaces to perform autoinstallation and IP address acquisition protocols for each interface. The router uses the protocols to send a request for an IP address for the interface:
[edit system] user@host# set autoinstallation interfaces ge-0/0/0 bootp
NOTE: Configuring an interface is optional. If an interface is configured, then autoinstallation process is triggered on the configured interface only. If an interface is not configured, then autoinstallation process is triggered on all the interfaces that are physically in link up state.
6. Copy the juniper-config.txt file to an external USB storage device. 7. Plug the external USB storage device to the router's USB port.

519
From configuration mode, confirm your configuration by entering the show system autoinstallation status command. If the output does not display the intended configuration, repeat the configuration instructions in this example to correct it.
user@host> show system autoinstallation status
Autoinstallation status: Master state: Active Last committed file: None Configuration server of last committed file: 10.25.100.1 Interface:
Name: ge-0/0/0 State: Configuration Acquisition Acquired:
Address: 192.168.124.75 Hostname: host-ge-000 Hostname source: DNS Configuration filename: router-ge-000.conf Configuration filename server: 10.25.100.3 Address acquisition: Protocol: BOOTP Client Acquired address: None Protocol: RARP Client Acquired address: None
SEE ALSO autoinstallation show system autoinstallation status

11 CHAPTER
Troubleshooting Software Installation
Troubleshooting Software Installation on EX Series Switches | 521 Troubleshooting a Switch That Has Booted from the Backup Junos OS Image |
527 Managing Disk Space for Junos OS Installation | 528 Verifying PIC Combinations | 529

521
Troubleshooting Software Installation on EX Series Switches
IN THIS SECTION Recovering from a Failed Software Upgrade on an EX Series Switch | 521 Rebooting from the Inactive Partition | 523 Freeing Disk Space for Software Installation | 524 Installation from the Boot Loader Generates 'cannot open package' Error | 525
This topic describes troubleshooting issues with software installations on EX Series switches.
Recovering from a Failed Software Upgrade on an EX Series Switch
IN THIS SECTION Problem | 521 Solution | 522
Problem Description
If Junos OS loads but the CLI is not working, or if the switch has no software installed, use this recovery installation procedure to install Junos OS.

522
Solution
If there is already a Junos OS image on the system, you can either install the new Junos OS package in a separate partition and have both Junos OS images remain on the system, or you can wipe the disk clean before the new installation proceeds. If there is no Junos OS image on the system, follow the instructions in Booting an EX Series Switch Using a Software Package Stored on a USB Flash Drive to get an image on the system and boot the switch. To perform a recovery installation: 1. Power on the switch.
The loader script starts. After the message Loading /boot/defaults/loader.conf displays, you are prompted with the following:
Hit [Enter] to boot immediately, or space bar for command prompt.
2. Press the space bar to enter the manual loader. The loader> prompt displays.
3. Enter the following command:
loader> install [­ ­format] [­ ­external] source
where: · format--Use this option to wipe the installation media before installing the software package. If
you do not include this option, the system installs the new Junos OS package in a different partition from the partition used by the most recently installed Junos OS package. · external--Use this option to install the software package on an external medium. · source--Represents the name and location of the Junos OS package either on a server on the network or as a file on the USB flash drive: · Network address of the server and the path on the server; for example, tftp://192.168.1.28/
junos/jinstall-ex-4200-9.4R1.5-domestic-signed.tgz · The Junos OS package on a USB device is commonly stored in the root drive as the only file;
for example, file:///jinstall-ex-4200-9.4R1.5-domestic-signed.tgz

523
The boot process proceeds as normal and ends with a login prompt.
Rebooting from the Inactive Partition
IN THIS SECTION Problem | 523 Solution | 524
Problem
Description EX Series switches shipped with Junos OS Release 10.4R2 or earlier have Junos OS loaded on the system disk in partition 1. The first time you upgrade, the new software package is installed in partition 2. When you finish the installation and reboot, partition 2 becomes the active partition. Similarly, subsequent software packages are installed in the inactive partition, which becomes the active partition when you reboot at the end of the installation process. On switches shipped with Release 10.4R3 and later, the same Junos OS image is loaded in each of the two root partitions, and you should copy the new software image to the alternate partition each time you upgrade. If you performed an upgrade and rebooted, the system resets the active partition. You can use this procedure to manually boot from the inactive partition.
NOTE: If you have completed the installation of the software image but have not yet rebooted, issue the request system software rollback command to return to the original software installation package.

524
Solution
Reboot from the inactive partition:
user@switch> request system reboot slice alternate
NOTE: If you cannot access the CLI, you can reboot from the inactive partition using the following procedure from the loader script prompt: 1. Unload and clear the interrupted boot from the active partition:
loader> unload loader> unset vfs.root.mountfrom 2. Select the new (inactive) partition to boot from: loader> set currdev=diskxsy: where x is either 0 (internal) or 1 (external), and the y indicates the number of the inactive partition, either 1 or 2. You must include the colon (:) at the end of this command. 3. Boot Junos OS from the inactive partition: loader> boot
Freeing Disk Space for Software Installation
IN THIS SECTION Problem | 525 Solution | 525

525
Problem Description
The software installation process requires a certain amount of unused disk space. If there is not enough space, you might receive an error message such as:
fetch: /var/tmp/incoming-package.tgz: No space left on device
Solution
Identify and delete unnecessary files by using the request system storage cleanup command.
Installation from the Boot Loader Generates 'cannot open package' Error
IN THIS SECTION Problem | 525 Solution | 526
Problem Description
When installing a Junos OS software image from the loader prompt, a "cannot open package error" is generated:
loader> install - -format tftp://10.204.33.248/images/Flash_corr/official/jinstall-ex-4200-10.4I2011012domestic-signed.tgz Speed: 1000, full duplex bootp: no reply No response for RARP request

526
net_open: RARP failed cannot open package (error 5)
Solution
This might be due to the IP address, gateway IP address, netmask address, or server IP address not being properly set. You can set these values either from the shell or from the u-boot prompt. To set these values from the shell:
% nvram setenv ipaddr 10.204.35.235 % nvram setenv netmask 255.255.240.0 % nvram setenv gatewayip 10.204.47.254 % nvram setenv serverip 10.204.33.248
To set these values from the u-boot prompt, log in to a console connection, reboot, and stop at the uboot prompt (Cntrl+c):
=> setenv ipaddr 10.204.35.235 => setenv gatewayip 10.204.47.254 => setenv serverip 10.204.33.248 => setenv netmask 255.255.240.0 => saveenv => printenv Verify whether variables are set properly or not => boot
RELATED DOCUMENTATION Installing Software on an EX Series Switch with a Virtual Chassis or Single Routing Engine (CLI Procedure) | 135 Upgrading Software on an EX6200 or EX8200 Standalone Switch Using Nonstop Software Upgrade (CLI Procedure) Installing Software on EX Series Switches (J-Web Procedure) Understanding Software Installation on EX Series Switches | 133 show system storage partitions | 852

527
Troubleshooting a Switch That Has Booted from the Backup Junos OS Image
IN THIS SECTION Problem | 527 Solution | 528

Problem
Description
The switch boots from the backup root file partition. It is possible that the primary copy of Junos OS failed to boot properly, which could indicate that it is corrupted. This event is flagged in two ways: · Upon login through the console or management port, the following warning message is displayed:

WARNING: THIS DEVICE HAS BOOTED FROM THE BACKUP JUNOS IMAGE
It is possible that the primary copy of JUNOS failed to boot up properly, and so this device has booted from the backup copy.
Please re-install JUNOS to recover the primary copy in case it has been corrupted.
· The following alarm message is generated:

user@switch> show chassis alarms

1 alarms currently active

Alarm time

Class Description

2011-02-17 05:48:49 PST Minor Host 0 Boot from backup root

If the switch is in a Virtual Chassis, the switch member number appears in the Description field, where the switch is called a host.

528
Solution
Install a new Junos OS image on the partition that had the corruption, or take a snapshot (use "request system snapshot" on page 655) of the currently active partition and use it to replace the image in the alternate partition: If the switch is a standalone switch or a Virtual Chassis primary switch, enter this command:
user@switch> request system snapshot slice alternate
If the switch is a Virtual Chassis member switch (not the primary), enter this command on the Virtual Chassis:
user@switch> request system snapshot slice alternate member member-id
where member-id is the Virtual Chassis member ID number.
RELATED DOCUMENTATION Verifying Junos OS and Boot Loader Software Versions on an EX Series Switch | 101 Troubleshooting Software Installation on EX Series Switches | 521 show system storage partitions | 852
Managing Disk Space for Junos OS Installation
A Junos OS installation or upgrade may fail if your router has a shortage of disk space. If a disk space error occurs, use one or more of the following options to complete the installation: · Use the request system storage cleanup command to delete unnecessary files and increase storage
space on the router. · Specify the unlink option when you use the request system software add command to install the
Junos OS: · On the M Series, MX Series, and T Series routers, the unlink option removes the software
package after a successful upgrade.

529
· Download the software packages you need from the Juniper Networks Support Web site at https:// www.juniper.net/support/. The download program provides intelligent disk space management to enable installation.
RELATED DOCUMENTATION Junos OS Configuration Using the CLI
Verifying PIC Combinations
On Juniper Networks routing platforms, you can typically install any combination of Physical Interface Cards (PICs) on a single Enhanced Flexible PIC Concentrator (FPC) or in two PIC slots served by a single Layer 2/Layer 3 Packet Processing application-specific integrated circuit (ASIC). Newer Junos OS services for some PICs can require significant Internet Processor ASIC memory, and some configuration rules limit certain combinations of PICs if they are installed on some platforms. During software installation, the configuration checker in the installation program checks the router's PICs. If any configuration rules affect your PIC combinations, the installation process stops and displays a message similar to the following:
The combination of PICS in FPC slot 3 is not supported with this release PIC slot 0 PIC slot 1 - 1x OC-12 ATM-II IQ PIC slot 2 - 1x G/E IQ, 1000 BASE PIC slot 3 - 1x Link Service (4)
If you continue the installation, one or more PICs on FPC slot 3 might appear to be online but cannot be enabled and cannot pass traffic with this release of JUNOS. See the Release Notes for more information. WARNING: This installation attempt will be aborted. If you WARNING: wish to force the installation despite these warnings WARNING: you may use the 'force' option on the command line. pkg_add: package /var/tmp/jbundle-7.6R1.x-domestic-signed.tgz fails requirements - not installed
The configuration checker has the following limitations:

530
· If a PIC is offline when you upgrade the router with new software, the configuration checker cannot detect PIC combinations affected by configuration rules and cannot warn about them.
· If you specify the force option when you upgrade the Junos OS, the configuration checker warns about the affected PIC combination and the software installation continues. However, after rebooting, one or more PICs might fail to initialize.
· The configuration checker looks for combinations of three affected PICs. If an Enhanced FPC contains four affected PICs, the script generates multiple warnings.
If you install a PIC into a router already running Junos OS, you can identify the presence of affected PIC combinations from messages in the system logging (syslog) file:
Feb 6 17:57:40 CE1 feb BCHIP 0: uCode overflow - needs 129 inst space to load b3_atm2_LSI_decode for stream 12
Feb 6 17:57:41 CE1 chassisd[2314]: CHASSISD_IFDEV_DETACH_PIC: ifdev_detach_pic(0/3)
Feb 6 17:57:41 CE1 feb BCHIP 0: binding b3_atm2_LSI_decode to stream 12 failed
Feb 6 17:57:41 CE1 feb PFE: can not bind B3 ucode prog b3_atm2_LSI_decode to FPC 0: stream 12
For more information about checking for unsupported PIC combinations, see the corresponding PIC guide for your router, the Junos OS Release Notes, and Technical Support Bulletin PSN-2004-12-002, PIC Combination Notes Summary on the Juniper Networks Support Web site at https:// www.juniper.net/support/.
For SRX Series Services Gateways
SRX5600 and SRX5800 devices support IOC or SPC on any given card slot, and there is no complexity in equipping the services gateways with the perfect balance of processing and I/O capacity. You can install up to 11 (on SRX5800) and 5 (SRX5600) SPCs and IOCs on the device. However, you must install at least one SPC on device. For more details, see SRX5600 and SRX5800 Services Gateway Card Guide.
SRX3600 supports a maximum of up to seven SPCs,three NPCs, six IOCs, and 11 NP-IOCs per chassis. However you must install at least one SPcs and NPC on the chassis. SRX3400 supports a maximum of up to four SPCs,two NPCs, four IOCs, and six NP-IOCs per chassis. However you must install at least one SPcs and NPC on the chassis. On SRX3400 and SRX3600 devices you must install PICs on the front slots of the chassis. For more details, see SR X1400 , SRX3400 , and SRX3600 Services Gateway Module Guide.

531
RELATED DOCUMENTATION System Memory and Storage Media for SRX Series Services Gateways | 398 Storage Media Names for SRX Series Devices

12 CHAPTER
Configuration Statements
auto-configuration | 534 auto-configuration (System) | 535 auto-image-upgrade | 538 auto-snapshot | 540 autoinstallation | 542 autoinstallation (JNU Satellite Devices) | 544 bootp | 546 commit (System) | 548 commit-synchronize-server | 551 configuration-servers | 553 delete-after-commit (JNU Satellites) | 555 file (App Engine Virtual Machine Management Service) | 557 flag (App Engine Virtual Machine Management Service) | 559 interfaces (Autoinstallation) | 562 level (App Engine Virtual Machine Management Service) | 564 license | 566 nextboot | 568 notification (Commit) | 570 traceoptions (App Engine Virtual Machine Management Service) | 571 traceoptions (System License) | 573

usb | 576 vmhost | 578 vmhost management-if disable | 581 vmhost management-if link-mode | 583 vmhost management-if speed | 585 upgrade-mode | 587

534
auto-configuration
IN THIS SECTION Syntax | 534 Hierarchy Level | 534 Description | 534 Options | 535 Required Privilege Level | 535 Release Information | 535
Syntax
auto-configuration { command binary-file-path; disable;
}
Hierarchy Level
[edit system processes]
Description
Configure the autoconfiguration process.

535
Options
· command binary-file-path--Path to the binary process. · disable--Disable the autoconfiguration process.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 8.5.
RELATED DOCUMENTATION Autoinstallation Overview Example: Configuring Autoinstallation on SRX Series Devices | 492
auto-configuration (System)
IN THIS SECTION Syntax | 536 Hierarchy Level | 536 Description | 536 Options | 536 Required Privilege Level | 538 Release Information | 538

536
Syntax
auto-configuration { traceoptions { file { filename; files number; match reqular-expression; size maximum-file-size; (world-readable | no-world-readable); } flag flag; level (all | error | info | notice | verbose | warning); no-remote-trace; }
}
Hierarchy Level
[edit system]
Description
Configure the autoconfiguration process.
Options
traceoptions--Set the trace options. · file--Configure the trace file information.
· filename--Name of the file to receive the output of the tracing operation. Enclose the name within quotation marks. All files are placed in the directory /var/log. By default, the name of the file is the name of the process being traced.

537
· files number--Maximum number of trace files. When a trace file named trace-file reaches its maximum size, it is renamed to trace-file.0, then trace-file.1, and so on, until the maximum number of trace files is reached. The oldest archived file is overwritten.
If you specify a maximum number of files, you also must specify a maximum file size with the size option and a filename.
Range: 2 through 1000 files
Default: 10 files
· match regular-expression--Refine the output to include lines that contain the regular expression.
· size maximum-file-size--Maximum size of each trace file, in kilobytes (KB), megabytes (MB), or gigabytes (GB). When a trace file named trace-file reaches this size, it is renamed trace-file.0. When trace-file again reaches its maximum size, trace-file.0 is renamed trace-file.1 and trace-file is renamed trace-file.0. This renaming scheme continues until the maximum number of trace files is reached. Then the oldest trace file is overwritten.
If you specify a maximum number of files, you also must specify a maximum file size with the size option and a filename.
Syntax: x K to specify KB, x m to specify MB, or x g to specify GB
Range: 10 KB through 1 GB
Default: 128 KB
· world-readable | no-world-readable--By default, log files can be accessed only by the user who configures the tracing operation. The world-readable option enables any user to read the file. To explicitly set the default behavior, use the no-world-readable option.
· flag--Specify the tracing operation to perform. To specify more than one tracing operation, include multiple flag statements. You can include the following flags.
· all--Trace all events.
· auth--Trace VLAN authentication.
· configuration--Trace configurations.
· interfaces--Trace interface operations.
· io--Trace I/O operations.
· rtsock--Trace routing socket operations.
· ui--Trace user interface operations.

538
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced before Junos OS Release 7.4.
RELATED DOCUMENTATION Autoinstallation Overview Example: Configuring Autoinstallation on SRX Series Devices | 492
auto-image-upgrade
IN THIS SECTION Syntax | 538 Hierarchy Level | 539 Description | 539 Default | 539 Required Privilege Level | 539 Release Information | 539
Syntax
auto-image-upgrade;

539
Hierarchy Level
[edit chassis]
Description
Enable automatic software download using Zero Touch Provisioning (ZTP). If the auto-image-upgrade statement is included in the factory default configuration, then ZTP will start automatically when the device is booted up. Otherwise, ZPT will start with the first power cycle after the auto-image-update statement is configured. The DHCP client compares the software package name in the DHCP server message to the name of the software package that booted the switch. If the software packages are different, the DHCP client downloads and installs the software package specified in the DHCP server message. Before you upgrade software using automatic software download, ensure that you have configured DHCP services, including configuring a path to a boot server and a boot file. See the Junos OS System Basics Configuration Guide for information about using the CLI to configure DHCP services and settings.
Default
Automatic software download is disabled.
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.6.

540 RELATED DOCUMENTATION
Upgrading Software by Using Automatic Software Download for Switches | 165 Understanding Software Installation on EX Series Switches | 133
auto-snapshot
IN THIS SECTION Syntax | 540 Hierarchy Level | 540 Description | 541 Default | 541 Required Privilege Level | 541 Release Information | 542
Syntax
auto-snapshot;
Hierarchy Level
[edit system]

541
Description
Enable the automatic snapshot feature, which allows the device to automatically fix a corrupt Junos OS file in the primary root partition. If the automatic snapshot feature is enabled, the device automatically takes a snapshot of the Junos OS root file system in the alternate root partition and copies it onto the primary root partition, thereby repairing the corrupt file in the primary root partition. The automatic snapshot procedure takes place whenever the system reboots from the alternate root partition, regardless of whether the reboot is due to a command or due to corruption of the primary root partition.
NOTE: EX9200 devices do not support the automatic snapshot feature.
Default
· The automatic snapshot feature is enabled by default on the following EX Series devices: · EX4550 devices · EX Series devices that ship with Junos OS Release 12.3R1 or later
· The automatic snapshot feature is disabled by default on EX Series devices (except the EX4550 devices) running Junos OS Release 12.2 or earlier.
· If the automatic snapshot feature was disabled by default before the device was upgraded to Junos OS Release 12.3R1 or later, the feature remains disabled (for backward compatibility) by default after the upgrade.
· By default, the auto-snapshot feature is disabled on SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices.
Required Privilege Level
system--To view this statement in the configuration.
system-control--To add this statement to the configuration.

542
Release Information
Statement introduced in Junos OS Release 12.3.
RELATED DOCUMENTATION Configuring Dual-Root Partitions | 365 show system auto-snapshot | 824
autoinstallation
IN THIS SECTION Syntax | 542 Hierarchy Level | 543 Description | 543 Options | 543 Required Privilege Level | 543 Release Information | 543
Syntax
autoinstallation { configuration-servers { url { password password; } } interfaces { interface-name { bootp;

543
rarp; } } usb { disable; } }
Hierarchy Level
[edit system]
Description
Specify the configuration for autoinstallation.
Options
The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced before Junos OS Release 7.4.

544
RELATED DOCUMENTATION Example: Configuring Autoinstallation on SRX Series Devices | 492
autoinstallation (JNU Satellite Devices)
IN THIS SECTION Syntax | 544 Hierarchy Level | 545 Description | 545 Options | 545 Required Privilege Level | 545 Release Information | 545
Syntax
autoinstallation { delete-after-commit; configuration-servers { url; } interfaces { interface-name { bootp; rarp; } }
}

545
Hierarchy Level
[edit system]
Description
(Satellite devices in a JNU group) Download a configuration file automatically from an FTP or HTTP server. When you power on a router or switch configured for autoinstallation, it requests an IP address from a Dynamic Host Configuration Protocol (DHCP) server. When the router or switch has an address, it sends a request to a configuration server and downloads and installs a configuration.
Options
The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 13.3.
RELATED DOCUMENTATION Autoinstallation of Satellite Devices in a Junos Node Unifier Group Autoinstallation Process on Satellite Devices in a Junos Node Unifier Group Configuring Autoinstallation on JNU Satellite Devices | 501 Verifying Autoinstallation on JNU Satellite Devices | 503

546
delete-after-commit (JNU Satellites) | 555
bootp
IN THIS SECTION Syntax | 546 Hierarchy Level | 546 Description | 547 Options | 547 Required Privilege Level | 547 Release Information | 547
Syntax
bootp { command binary-file-path; disable; failover (alternate-media | other-routing-engine);
}
Hierarchy Level
[edit system processes]

547
Description
Specify the booting process.
Options
· command binary-file-path--Path to the binary process. · disable --Disable the booting process. · failover--Configure the device to reboot if the software process fails four times within 30 seconds,
and specify the software to use during the reboot. · alternate-media--Configure the device to switch to backup media that contains a version of the
system if a software process fails repeatedly. · other-routing-engine--Instruct the secondary Routing Engine to take primary role if a software
process fails. If this statement is configured for a process, and that process fails four times within 30 seconds, then the device reboots from the secondary Routing Engine.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 8.5.

548
commit (System)
IN THIS SECTION Syntax | 548 Hierarchy Level | 548 Description | 549 Options | 549 Required Privilege Level | 550 Release Information | 550
Syntax
commit { commit-synchronize-server; delta-export; fast-synchronize; notification; peers; peers-synchronize; persist-groups-inheritance | no-persist-groups-inheritance; server; synchronize;
} The parameters for fast-synchronize and synchronize do not apply for the SRX Series.
Hierarchy Level
[edit system]

549
Description
Configure options for Junos OS commit.
Options
commit-synchronize-server--(Optional) Specify traceoptions for commit synchronize server actions. delta-export--(Optional) Configure system commit to export only the changes made in the candidate configuration instead of exporting the entire candidate configuration to the configuration database. This helps to reduce the time taken to commit the configuration changes.. fast-synchronize--(Optional) Configure commits to run in parallel (simultaneously) on both the primary and backup Routing Engines to reduce the time required for commit synchronization. The fastsynchronize configuration is valid only on systems with two Routing Engines. (Option not available for SRX Series.) notification--(Optional) Notify applications upon commit completion. peers--(Optional) Specify the host names or IP addresses of the MC-LAG peers and the user authentication details for the users administering the MC-LAG peers that are participating in commit synchronization.
NOTE: Starting in Junos OS Release 17.1R1, the peers option at the [edit system commit] hierarchy level is not supported in batch configuration mode.
peers-synchronize--(Optional) Configure a commit synchronization on MC-LAG peers. persist-group-inheritance--(Optional) Configure this option to improve commit performance for systems that use many configuration groups that use wildcards. This option causes the full inheritance paths of the configuration groups to be built in the database instead of in the process memory. Starting in Junos OS Evolved Release 19.2R1 and Junos OS Release 19.4R1, this option is enabled by default. To disable this option, use no-persist-groups-inheritance. server--(Optional) Configure a default batch commit. synchronize--(Optional) For devices with multiple Routing Engines only. Configure the commit command to automatically perform a commit synchronize action between dual Routing Engines within the same chassis. The Routing Engine on which you execute the commit command (the requesting Routing Engine) copies and loads its candidate configuration to the other (the responding) Routing Engine. Each Routing Engine then performs a syntax check on the candidate configuration file being committed. If no

550
errors are found, the configuration is activated and becomes the current operational configuration on both Routing Engines. (Option not available for SRX Series.) The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
maintenance--To view this statement in the configuration. maintenance-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 7.4. Option persist-groups-inheritance added in Junos OS Release 13.2. Option delta-export added in Junos OS Release 14.2. Option peers added in Junos OS Release 14.2R6. Option peers-synchronize added in Junos OS Release 14.2R6. Option no-persist-groups-inheritance added in Junos OS Evolved Release 19.2R1 and Junos OS Release 19.4R1.
RELATED DOCUMENTATION Improving Commit Time When Using Configuration Groups server synchronize

551
commit-synchronize-server
IN THIS SECTION Syntax | 551 Hierarchy Level | 551 Description | 552 Options | 552 Required Privilege Level | 553 Release Information | 553
Syntax
commit-synchronize-server { traceoptions { file { filename; files number; microsecond-stamp; size maximum-file-size; (world-readable | no-world-readable); } flag (all | debug | ephemeral-commit | operational-command); no-remote-trace; }
}
Hierarchy Level
[edit system commit]

552
Description
For commit synchronize server actions, configure tracing operations.

Options
filename

Name of the file to receive the output of the tracing operation.

NOTE: If you configure traceoptions and do not explicitly specify a filename for logging the events, the events are logged in the file /var/log/ commitd by default.

files number

Maximum number of trace files.

microsecond-stamp Include microsecond in the timestamp.

size

Maximum size of each trace file, in kilobytes (KB), megabytes (MB), or gigabytes

(GB).

world-readable | no- Grant all users permission to read archived log files, or restrict the permission

world-readable

only to the root user and users who have the Junos OS maintenance permission.

flag flag

Tracing operation to perform. To specify more than one tracing operation, include multiple flag statements. You can include the following flags:
· all--All tracing operations flags.

· debug--Trace operations for debug events.

· ephemeral-commit--Trace operations for ephemeral database commit synchronize events.

· operational-command--Trace operations for operational command events.

world-readable | no- Grant all users permission to read archived log files, or restrict the permission

world-readable

only to the root user and users who have the Junos OS maintenance permission.

no-remote-trace

Disable remote tracing.

553
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 16.1R3.
RELATED DOCUMENTATION commit (System) | 548
configuration-servers
IN THIS SECTION Syntax | 553 Hierarchy Level | 554 Description | 554 Options | 554 Required Privilege Level | 554 Release Information | 555
Syntax
configuration-servers { url { password password;

554
} }
Hierarchy Level
[edit system autoinstallation]
Description
Configure the URL address of a server from which the configuration files must be obtained. You can download a configuration file automatically from an FTP, Hypertext Transfer Protocol (HTTP), or Trivial FTP (TFTP) servers. Examples of URLs: · tftp://hostname/path/filename · ftp://username:password@ftp.hostname.net · http://hostname/path/filename · http://usenamer:password@httpconfig.sp.com
Options
· url--Specify the URL address of the server containing the configuration files. · password--Specify the password for authentication with the configuration server. Specifying a
password in URLs and in the password option might result in commit failure. We recommend you to use the password option for specifying the password.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.

555
Release Information
Statement introduced before Junos OS Release 7.4.
RELATED DOCUMENTATION Example: Configuring Autoinstallation on SRX Series Devices | 492
delete-after-commit (JNU Satellites)
IN THIS SECTION Syntax | 555 Hierarchy Level | 555 Description | 556 Required Privilege Level | 556 Release Information | 556
Syntax
delete-after-commit;
Hierarchy Level
[edit system autoinstallation]

556
Description
Specify that during the subsequent commit operation of configuration settings (after the autoinstallation process successfully retrieves, installs, and commits the configuration), the autoinstallation configuration parameters be removed from the router. Removal of the autoinstallation parameters and statements from the committed configuration on the router ensures that the router does not attempt to perform an autoinstallation process when it is powered on the next time. Although you can optionally specify the interfaces to perform autoinstallation or configuration servers from which the files are to be downloaded, you must include the delete-after-commit statement to prevent the router from entering a recursive loop and repeatedly performing an autoinstallation every time it is powered on.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 13.3.
RELATED DOCUMENTATION Autoinstallation of Satellite Devices in a Junos Node Unifier Group Autoinstallation Process on Satellite Devices in a Junos Node Unifier Group Configuring Autoinstallation on JNU Satellite Devices | 501 Verifying Autoinstallation on JNU Satellite Devices | 503 autoinstallation (JNU Satellite Devices) | 544

557
file (App Engine Virtual Machine Management Service)
IN THIS SECTION Syntax | 557 Hierarchy Level | 557 Description | 557 Options | 558 Required Privilege Level | 558 Release Information | 559
Syntax
file {filename <files number> | match | no-world-readable | size size | worldreadable }
Hierarchy Level
[edit system processes app-engine-virtual-machine-management-service traceoptions]
Description
Trace file information for the Virtual Machine Management Daemon ( vmmd), which communicates with the host OS.

558

Options

filename files number
match no-worldreadable sizesize
worldreadable

Name of the file in which the trace information is stored. By default, the file is created in the /var/log directory.
(Optional) Maximum number of trace files. When a trace file reaches the size specified by the size option, the filename is appended with 0 and compressed. For example, when a trace file named trace-file-log reaches size size, it is compressed and renamed as tracefile-log.0.gz. When trace-file-log reaches size size for the second time, trace-file-log.0.gz is renamed as trace-file-log.1.gz and trace-file-log is compressed and renamed as tracefile-log.0.gz. This renaming sheme ensures that the older logs have a greater index number. When number of trace files reaches number, the oldest file is deleted.
If you specify a maximum number of files, you also must specify a maximum file size with the size option and a filename.
· Range: 2 through 1000
· Default: 10
Refine the output to include only those lines that match the given regular expression.
Restrict file access to the user who created the trace files.
Maximum size of each trace file . By default, the number entered is treated as bytes. Alternatively, you can include a suffix to the number to indicate kilobytes (KB), megabytes (MB), or gigabytes (GB). If you specify a maximum file size, you also must specify a maximum number of trace files with the files option.
· Range: 10 KB through 1 GB
· Default: 128 KB
Enable unrestricted file access.

Required Privilege Level
system-control

559
Release Information
Statement introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION traceoptions (App Engine Virtual Machine Management Service) | 571 level (App Engine Virtual Machine Management Service) | 564 flag (App Engine Virtual Machine Management Service) | 559
flag (App Engine Virtual Machine Management Service)
IN THIS SECTION Syntax | 560 Hierarchy Level | 560 Description | 560 Default | 560 Options | 560 Required Privilege Level | 561 Release Information | 561

560
Syntax
flag (all |ccif | configuration | heartbeat | init | miscellaneous | platform | pxe | routing-instances | snmp)

Hierarchy Level
[edit system processes app-engine-virtual-machine-management-service traceoptions]

Description
Perform different tracing operations. To specify more than one tracing operation, include multiple flag statements.

Default
Tracing operations are not performed.

Options
all ccif configuration heartbeat init

Trace all events. Trace compute node interface events. This is the default option. Trace configuration events. Trace compute node heartbeat-related events. Trace initialization events.

561

miscellaneous platform pxe routing-instances snmp

Trace miscellaneous events. Trace platform-related events. Trace events related to Preboot Execution Environment (PXE). Trace events related to routing instances. Trace SNMP events.

Required Privilege Level
system-control
Release Information
Statement introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

RELATED DOCUMENTATION
traceoptions (App Engine Virtual Machine Management Service) | 571 file (App Engine Virtual Machine Management Service) | 557 level (App Engine Virtual Machine Management Service) | 564

562
interfaces (Autoinstallation)
IN THIS SECTION Syntax | 562 Hierarchy Level | 562 Description | 562 Options | 563 Required Privilege Level | 563 Release Information | 563
Syntax
interfaces { interface-name { bootp; rarp; }
}
Hierarchy Level
[edit system autoinstallation]
Description
Configure the interface on which to perform autoinstallation. A request for an IP address is sent from the interface. Specify the IP address procurement protocol.

563
NOTE: When you run the system autoinstallation command, the command will configure unit 0 logical interface for all the active state physical interfaces. However, few commands like fabricoptions do not allow its physical interface to be configured with a logical interface. If the system autoinstallation and the fabric-options commands are configured together the following message is displayed incompatible with 'system autoinstallation'.
Options
· bootp--Enables BOOTP or DHCP during autoinstallation. · rarp--Enables RARP during autoinstallation.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced before Junos OS Release 7.4.
RELATED DOCUMENTATION Autoinstallation Overview Example: Configuring Autoinstallation on SRX Series Devices | 492

564
level (App Engine Virtual Machine Management Service)
IN THIS SECTION Syntax | 564 Hierarchy Level | 564 Description | 564 Default | 565 Options | 565 Required Privilege Level | 565 Release Information | 565
Syntax
level (all | error| info | notice | verbose | warning)
Hierarchy Level
[edit system processes app-engine-virtual-machine-management-service traceoptions]
Description
Set level of debugging output.

565
Default
info

Options
all error info notice verbose warning

Match all levels. Match error conditions. Match informational messages. Match conditions that must be handled specially. Match verbose messages. Match warning messages.

Required Privilege Level
system-control
Release Information
Statement introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

RELATED DOCUMENTATION
traceoptions (App Engine Virtual Machine Management Service) | 571 flag (App Engine Virtual Machine Management Service) | 559 file (App Engine Virtual Machine Management Service) | 557

566
license
IN THIS SECTION Syntax | 566 Hierarchy Level | 567 Description | 567 Options | 567 Required Privilege Level | 568 Release Information | 568
Syntax
license { autoupdate { url url <password password>; } keys { key key } renew { before-expiration number; interval interval-hours; } traceoptions { file { filename; files number; match regular-expression; size maximum-file-size; (world-readable | no-world-readable); } flag flag; no-remote-trace;

567
} }

Hierarchy Level
[edit system]

Description
Specify license information for the device.

Options
autoupdate before-expiration number interval interval-hours keys key key
renew

Autoupdate license keys from license servers.
License renewal lead time before expiration, in days. · Range: 0 through 60 days
License checking interval, in hours. · Range: 1 through 336 hours
Configure one or more license keys. For example,
[edit] user@device# set system license keys key "key_1" user@device# set system license keys key "key_2" user@device# set system license keys key "key_3" user@device# set system license keys key "key_4" user@device# commit commit complete
License renewal lead time and checking interval.

568

url

URL of a license server.

The remaining statements are explained separately. See CLI Explorer.

Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.

Release Information
Statement introduced in Junos OS Release 8.5. Options keys introduced in Junos OS Release 14.1X53-D10.

nextboot

IN THIS SECTION
Syntax | 569 Hierarchy Level | 569 Description | 569 Required Privilege Level | 569 Release Information | 569

569
Syntax
nextboot { media-device;
}
Hierarchy Level
[edit]
Description
You can use the nextboot function to check the current bootup device. This function lists the available boot device choice for the media devices and current settings.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 20.3R1.
RELATED DOCUMENTATION Veriexec Overview | 299

570
notification (Commit)
IN THIS SECTION Syntax | 570 Hierarchy Level | 570 Description | 570 Options | 570 Required Privilege Level | 571 Release Information | 571
Syntax
notification;
Hierarchy Level
[edit system commit]
Description
Notify applications upon commit completion.
Options
There are no options for this configuration statement.

571
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 16.1R3.
RELATED DOCUMENTATION commit (System) | 548
traceoptions (App Engine Virtual Machine Management Service)
IN THIS SECTION Syntax | 572 Hierarchy Level | 572 Description | 572 Default | 572 Options | 572 Required Privilege Level | 573 Release Information | 573

572
Syntax
traceoptions { file filename <files number> | match | no-world-readable |<size size> <world-
readable >; flag (all |ccif | configuration | heartbeat | init | miscellaneous |
platform | pxe | routing-instances | snmp); level (all | error| info | notice | verbose | warning)
}

Hierarchy Level
[edit system processes app-engine-virtual-machine-management-service]

Description
Enable traceoptions for the app-engine virtual machine management service system process.

Default
Traceoptions are not enabled.

Options
file flag level no-remote-trace

Trace file information. Perform defined tracing operation. Set traceoptions level. Disable remote tracing.

573
The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
system-control
Release Information
Statement introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION processes level (App Engine Virtual Machine Management Service) | 564 flag (App Engine Virtual Machine Management Service) | 559 file (App Engine Virtual Machine Management Service) | 557
traceoptions (System License)
IN THIS SECTION Syntax | 574 Hierarchy Level | 574 Description | 574 Options | 574 Required Privilege Level | 576

574 Release Information | 576

Syntax
traceoptions { file { filename; files number; match regular-expression; size maximum-file-size; (world-readable | no-world-readable); } flag flag; no-remote-trace;
}

Hierarchy Level
[edit system license]

Description
Set trace options for licenses.

Options

file

Configure the trace file information.

575

filename

Name of the file to receive the output of the tracing operation. Enclose the name within quotation marks. All files are placed in the directory /var/ log. By default, the name of the file is the name of the process being traced.

files number

Maximum number of trace files. When a trace file named trace-file reaches its maximum size, it is renamed trace-file.0, then trace-file.1, and so on, until the maximum number of trace files is reached. Then the oldest trace file is overwritten.
If you specify a maximum number of files, you also must specify a maximum file size with the size maximum file-size option.
· Range: 2 through 1000 files

· Default: 10 files

match regularexpression size size

Refine the output to include lines that contain the regular expression.
Maximum size of each trace file, in kilobytes (KB), megabytes (MB), or gigabytes (GB). If you specify a maximum file size, you also must specify a maximum number of trace files with the files number option. · Range: 10 KB through 1 GB

· Default: 128 KB

worldreadable | noworldreadable

By default, log files can be accessed only by the user who configures the tracing operation. The world-readable option enables any user to read the file. To explicitly set the default behavior, use the no-world-readable option.

flag flag noremotetrace

Specify which tracing operation to perform. To specify more than one tracing operation, include multiple flag statements. You can include the following flags. · all--Trace all operations. · config--Trace license configuration processing. · events--Trace licensing events and their processing.
Disable the remote tracing.

576
Required Privilege Level
trace--To view this statement in the configuration. trace-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 8.5.
usb
IN THIS SECTION Syntax | 576 Hierarchy Level | 577 Description | 577 Options | 577 Required Privilege Level | 577 Release Information | 577
Syntax
usb { disable;
}

577
Hierarchy Level
[edit system autoinstallation]
Description
Disable the USB autoinstallation process.
Options
disable--Disable the process.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced before Junos OS Release 7.4.
RELATED DOCUMENTATION Example: Configuring Autoinstallation on SRX Series Devices | 492

578
vmhost
IN THIS SECTION Syntax | 578 Hierarchy Level | 579 Description | 579 Options | 580 Required Privilege Level | 581 Release Information | 581
Syntax
vmhost { interfaces name { family { (inet | inet6) { address name { master-only; } gateway gateway; } } } management-if { disable; link-mode (automatic | full-duplex | half-duplex); speed (100m | 10m | 1g | automatic); } no-auto-recovery; resize { vjunos { compact; } }

579
services { ssh { root-login (allow | deny); }
} syslog {
file name { vmhost-syslog-object (any | authorization | cron | daemon | kernel |
local0 | local1 | local2 | local3 | local4 | local5 | local6 | local7 | lpr | mail | mark | news | privileged | syslog | user | uucp) {
level; } } host name { transport (tcp | udp); vmhost-syslog-object (any | authorization | cron | daemon | kernel | local0 | local1 | local2 | local3 | local4 | local5 | local6 | local7 | lpr | mail | mark | news | privileged | syslog | user | uucp) {
level; } } } }
Hierarchy Level
[edit]
Description
Configure VM host management properties. Set values in the edit vmhost hierarchy of the configuration.

580

Options

interfaces

Configure interface properties of the host.
· management-if0 | management-if1--Configure the host's side management interface0 or interface1.
family (inet|inet6) address-- Configure IPv4 or IPv6 parameters.
primary-only-- Configure the IP address to be used when the Routing Engine is the current primary. The configured IP address is assigned to primary RE host when the Routing Engine is the current primary. It is recommended to set this option for platforms with dual Routing Engine architecture with VM host support.
gateway-- Configure gateway IP address.

management-if Configure management interface properties of the host. · disable--Disable the host interface eth0, which serves as the management port

· link-mode (automatic | half-duplex | full-duplex)--Configure the link mode of the host interface eth0, which serves as the management port as half-duplex or fullduplex. You can also manually select the link mode option as either half-duplex or full-duplex.

· speed (automatic | 10m | 100m | 1g)--Configure the link speed of the host interface eth0, which serves as the management port. If you set the link speed as 10m or 100m, autonegotiation is turned off and the link speed is the speed that you specify.

no-autorecovery services

Disable the automatic guest recovery by the host.
Enable ssh access to the host and enable or disable root-login to the host from guest. · ssh--Allow ssh access
root-login--Configure host root access through ssh allow | deny--Allow or deny root access through ssh.

syslog

Enable the remote syslog configuration from guest to host OS. Based on the severity configured on guest, the syslog information is logged onto the /etc/syslog.conf file on the host.
· host <host-name>--Host notified for remote syslog configuration.

581
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION Routing Engines with VM Host Support | 309 Disabling Autorecovery on Routing Engines with VM Host Support | 343
vmhost management-if disable
IN THIS SECTION Syntax | 582 Hierarchy Level | 582 Description | 582 Default | 582 Required Privilege Level | 582 Release Information | 582

582
Syntax
vmhost management-if disable
Hierarchy Level
[edit vmhost]
Description
Disable the host interface eth0, which serves as the management port. You can the disable the interface if there are any issues associated with security or any hardware failures either at the local end or the remote end of the interface. if you disable the interface, the transmitter is turned off and the link partner experiences a link-down condition.
Default
The host interface eth0 which serves as the management port is enabled.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 15.1F6.

583
NOTE: The command is supported on the routers with RE-MX-X6, RE-MX-X8, and RE-PTX-X8 Routing Engines only.
RELATED DOCUMENTATION vmhost | 578 vmhost management-if speed | 585 vmhost management-if link-mode | 583 show vmhost management-if | 929
vmhost management-if link-mode
IN THIS SECTION Syntax | 583 Hierarchy Level | 584 Description | 584 Default | 584 Options | 584 Required Privilege Level | 584 Release Information | 585
Syntax
vmhost management-if link-mode (automatic | half-duplex | full-duplex)

584
Hierarchy Level
[edit vmhost]
Description
Configure the link mode of the host interface eth0, which serves as the management port as half-duplex or full-duplex. You can also manually select the link mode option as either half-duplex or full-duplex.
Default
The link partners auto-negotiate the speed and duplex link mode and select the highest common capability.
Options
automatic Autonegotiate the link mode of the management interface. if you set the link mode to automatic, you must also set the link speed to automatic.
half-duplex Set the link mode of the management interface to half-duplex. full-duplex Set the link mode of the management interface to full-duplex.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.

585
Release Information
Statement introduced in Junos OS Release 15.1F6.
NOTE: The command is supported on the routers with RE-MX-X6, RE-MX-X8, and RE-PTX-X8 Routing Engines only.
RELATED DOCUMENTATION vmhost | 578 vmhost management-if disable | 581 vmhost management-if speed | 585 show vmhost management-if | 929
vmhost management-if speed
IN THIS SECTION Syntax | 586 Hierarchy Level | 586 Description | 586 Default | 586 Options | 586 Required Privilege Level | 587 Release Information | 587

586
Syntax
vmhost management-if speed { automatic | 10m | 100m | 1g }

Hierarchy Level
[edit vmhost]

Description
Configure the link speed of the host interface eth0, which serves as the management port. If you set the link speed as 10m or 100m, autonegotiation is turned off and the link speed is the speed that you specify.

Default
The link partners auto-negotiate the speed and duplex link mode and select the highest common capability.

Options

automatic Autonegotiate the link speed of the management interface. If you set the link speed as automatic, speed and link mode are auto-negotiated with the link partner.

10m

Set the link speed of the management interface to 10Mbps.

100m

Set the link speed of the management interface to 100Mbps

1g

Set the link speed of the management interface to 1Gbps. If you set link speed to 1Gbps,

autonegotiation is enabled. However, the interface advertises only 1Gbps speed and full-

duplex mode.

587
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 15.1F6.
NOTE: The command is supported on the routers with RE-MX-X6, RE-MX-X8, and RE-PTX-X8 Routing Engines only.
RELATED DOCUMENTATION vmhost | 578 vmhost management-if disable | 581 vmhost management-if link-mode | 583 show vmhost management-if | 929
upgrade-mode
IN THIS SECTION Syntax | 588 Hierarchy Level | 588 Description | 588 Options | 588 Required Privilege Level | 589 Release Information | 589

588
Syntax
upgrade-mode (3d-fabric | default | t4000);

Hierarchy Level
[edit chassis fabric], [edit chassis member name fabric]

Description
Configures upgrade mode for SIBs and forces them to operate in the same mode until the upgrade is complete. Upgrade mode is used so that two different types of SIBs can be installed in an operational router or routing matrix. After you upgrade the SIBs delete the upgrade-mode statement from the configuration. See the hardware installation guide for your router for more information about upgrading SIBs in an operational router or routing matrix.

Options

3d-fabric

Enables the TX Matrix Plus router to upgrade to a TX Matrix Plus router with 3D SIBs. On the SFC, enables setting proper support for mixed SIBs (TXP-F13 SIB and TXP-F13-3D SIB). On the T640 or T1600 or T4000 routers in a routing matrix enables support for mixed SIBs (TXP-T1600 SIB and TXP-3D-LCC SIBs on the T1600 router and SIB-I-T4000 and TXP-3DLCC SIBs on the T4000 router).

default Enables support for mixed SIBs when upgrading SIBs in the PTX3000 and PTX5000 routers.

t4000 Enables support for mixed SIBs when upgrading to SIB-I-T4000 SIBs in a T640 or T1600.

589
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 7.5.
RELATED DOCUMENTATION TX Matrix Router and T640 Router Configuration Overview Configuring Junos OS to Upgrade a T4000 Router to LCC 0 of a TX Matrix Plus Router with 3D SIBs Configuring Junos OS to Upgrade the T1600 Router Chassis to LCC 0 of a TX Matrix Plus Router with 3D SIBs Upgrading an Operational Standalone Router and Integrating It into a TX Matrix Plus Routing Matrix with 3D SIBs Upgrading to SIB3-SFF-PTX SIBs in an Operational PTX3000 Upgrading the FPCs in an Operational PTX5000

13 CHAPTER
Operational Commands
clear system login lockout | 593 request app-engine cleanup | 594 request app-engine file-copy (crash | log) from-jhost to-vjunos | 597 request node (offline | online) | 599 request node reboot (re0 | re1) | 601 request system application | 603 request system autorecovery state | 605 request system configuration rescue delete | 608 request system configuration rescue save | 610 request system download abort | 611 request system download clear | 613 request system download pause | 615 request system download resume | 617 request system download start | 619 request system firmware upgrade | 621 request system halt | 624 request system partition compact-flash | 626 request system power-off | 629 request system reboot | 632 request system reboot (Junos OS with Upgraded FreeBSD) | 643

request system recover | 647 request system scripts add | 651 request system scripts delete | 652 request system scripts rollback | 654 request system snapshot | 655 request system snapshot (Junos OS with Upgraded FreeBSD) | 668 request system snapshot (Maintenance) | 673 request system software abort in-service-upgrade (ICU) | 677 request system software add | 679 request system software add (Maintenance) | 705 request system software configuration-backup | 707 request system software configuration-restore | 709 request system software delete | 711 request system software delete-backup | 717 request system software download | 719 request system software recover-from-restore-point | 721 request system software restore-point | 723 request system software rollback | 726 request system software rollback (SRX Series) | 733 request system software sync | 735 request system software validate | 741 request system software validate on (Junos OS with Upgraded FreeBSD) | 747 request system software validate-restart | 751 request system storage cleanup | 754 request system storage cleanup (SRX Series) | 776 request system zeroize | 781 rollback | 786 show app-engine crash | 788 show app-engine logs | 790 show chassis usb storage | 794 show system applications | 796 show system autoinstallation status | 808 show system autorecovery state | 811 show system boot-messages | 813

show system auto-snapshot | 824 show system download | 826 show system login lockout | 829 show system rollback | 831 show system snapshot | 833 show system snapshot (Junos OS with Upgraded FreeBSD) | 838 show system snapshot media | 841 show system software list | 845 show system software restore-point-status | 847 show system software usb-software-version | 849 show system storage partitions | 852 show system ztp | 856 show version | 862

593
clear system login lockout
IN THIS SECTION Syntax | 593 Description | 593 Options | 593 Required Privilege Level | 594 Output Fields | 594 Release Information | 594

Syntax
clear system login lockout <all> <user username>

Description
Use this command to unlock the locked user account.

Options
all user username

Clear all locked user accounts. Clear the specified locked user account.

594
Required Privilege Level
clear
Output Fields
This command produces no output.
Release Information
Command introduced in Junos OS Release 11.2.
RELATED DOCUMENTATION retry-options show system login lockout | 829
request app-engine cleanup
IN THIS SECTION Syntax | 595 Description | 595 Options | 595 Required Privilege Level | 595 Output Fields | 595 Sample Output | 596 Release Information | 596

595
Syntax
request app-engine cleanup <compute-cluster compute-cluster-name> <compute-cluster compute-cluster-name compute-node compute-node-name>
Description
Cleans up temporary files on the Junos V App Engine or the host OS of QFX Series switches. This command deletes all files from the directories where temporary files are normally stored, such as /var/tmp and /var/log. Be sure to collect any temporary files and logs you want to save before running this command.
Options
· compute-cluster compute-cluster-name compute-node compute-node-name--Name of the compute cluster and name of the compute node. On QFX Series switches, the default names of the compute cluster and compute node are default-cluster and default-node, which applies to the host OS.
Required Privilege Level
view
Output Fields
For a description of the output fields, see Table 27 on page 596. Output fields are listed in the approximate order in which they appear.

596

Table 27: request app-engine cleanup Output Fields

Field Name

Field Description

Compute Cluster

Name of compute cluster.

Compute Node

Name of compute node.

Cleanup

Lists the directories that were cleaned up.

Sample Output
request app-engine cleanup (QFX 5100 Switches)
user@host> request app-engine cleanup user@host> request app-engine cleanup Compute cluster: default-cluster
Compute node: default-node
Cleanup (/var/tmp) =======

Release Information
Command introduced in Junos OS Release 13.1X51-D10.
RELATED DOCUMENTATION show app-engine crash | 788 show app-engine logs | 790

597
request app-engine file-copy (crash | log) from-jhost to-vjunos | 597
request app-engine file-copy (crash | log) from-jhost to-vjunos
IN THIS SECTION Syntax | 597 Description | 597 Options | 598 Additional Information | 598 Required Privilege Level | 598 Output Fields | 598 Sample Output | 599 Release Information | 599
Syntax
request app-engine file-copy (crash | log) from-jhost host-os-filename to-vjunos vjunos-filename
Description
In Junos OS environments with a host OS, copies core files (crash option) or system log files (log option) from the host OS to a Junos OS filename.

598
· crash option--Core files are copied from the directory where the host OS normally stores core files. For example, when the host OS is Linux, the source directory is /var/crash. The show app-engine crash command displays the list of core files available to copy from the host OS source directory.
· log option--Log files are copied from the directory where the host OS normally stores system log files. For example, when the host OS is Linux, the source directory is /var/log. The show app-engine logs command displays the list of system log files available to copy from the host OS source directory.
Either the crash or log option is required. When the destination Junos OS path for the to-vjunos argument is a directory, the destination filename is the source filename by default. To rename the file at the destination, specify a full path that includes a destination filename in the path with the to-vjunos argument.
Options
· from-jhost host-os-filename--Source filename to copy from the host OS. · to-vjunos vjunos-filename--Junos OS destination path (with or without a filename) to which the file
is copied. If this path is a directory, the source filename is used as the destination filename by default.
Additional Information
This command does not apply to accessing files on guest virtual machines (VMs) on QFX Series devices that support guest VMs.
Required Privilege Level
view
Output Fields
This command produces no output. To see the results of the copy operation, you can run Junos OS commands for viewing files, such as file list with the destination directory, show system core-dumps, or show log.

599
Sample Output
request app-engine file-copy crash
user@host> request app-engine file-copy crash from-jhost localhost.dcfpe.6449.1454328456.core.tgz tojunos /var/tmp user@host> show system core-dumps re0: --------------------------------------------------------------------------rw-r--r-- 1 user test 2538949 Feb 2 19:01 /var/tmp/ localhost.dcpfe.6449.1454328456.core.tgz total files: 1
Release Information
Command introduced in Junos OS Release 13.1X51-D10.
RELATED DOCUMENTATION show app-engine crash | 788 show app-engine logs | 790 request app-engine cleanup | 594
request node (offline | online)
IN THIS SECTION Syntax | 600 Description | 600 Options | 600

600
Required Privilege Level | 600 Release Information | 601

Syntax
request node (offline | online) node-name

Description
Use this command to change the node status to offline or online. · To add a node to the cluster, set the node status to online.
· To remove a node from the cluster, set the node status to offline. You can use the offline option to stop all applications on the node and move them to other nodes if applicable. The node is not allowed to join the cluster until the node is made online by using the request node online command. When you use the request node offline for fpc or spmb nodes, the node is powered off. When used for an re node, the node just reboots.

Options
node-name (offline | online)

Specify the node name. Specify node status online or offline.

Required Privilege Level
view

601
Release Information
Statement introduced in Junos OS Evolved Release 18.3R1.
RELATED DOCUMENTATION request node halt (Junos OS Evolved) | 0 request node power-off (Junos OS Evolved) | 0 request node power-on (Junos OS Evolved) | 0 request node reboot (re0 | re1) | 601 request system application | 603
request node reboot (re0 | re1)
IN THIS SECTION Syntax | 601 Description | 602 Options | 602 Required Privilege Level | 602 Release Information | 602
Syntax
request node reboot (re0 |re1) <(at time | in minutes)> <message message>

602
Description
Use this command to reboot a node on Routing Engine. To manage all nodes at once, use the request system shutdown command.

Options

(at time | in minutes) (Optional) Specify when the action is performed, either in time, in hh:mm format, or in number of minutes.

message message (Optional) Message to display to all users.

(re0 |re1)

Specify the Routing Engine to reboot.

Required Privilege Level
view
Release Information
Command introduced in Junos OS Evolved Release 18.3R1.
RELATED DOCUMENTATION request node halt (Junos OS Evolved) | 0 request node (offline | online) | 599 request node power-off (Junos OS Evolved) | 0 request node power-on (Junos OS Evolved) | 0 request system application | 603

603
request system application
IN THIS SECTION Syntax | 603 Description | 603 Options | 603 Required Privilege Level | 604 Sample Output | 604 Release Information | 604

Syntax

request system application app application-name node node-name restart

Description
Use this command to stop and then start (restart) an application on the specified node. Use the show system applications command to verify if an application is started or stopped.

Options

app application-name node node-name restart

Specify the application you want started or stopped. Specify the name of the node on which to start or stop the application. Restart the application.

604
Required Privilege Level
view
Sample Output
request system application app application-name node node-name restart
user@host> request system application app cmdd node fpc0 restart This may affect traffic in the system. Proceed ? [yes,no] (no) yes App cmdd on node fpc0 restart request is submitted
Release Information
Statement introduced in Junos OS Evolved Release 18.3R1.
RELATED DOCUMENTATION request node halt (Junos OS Evolved) | 0 request node (offline | online) | 599 request node power-off (Junos OS Evolved) | 0 request node power-on (Junos OS Evolved) | 0 request node reboot (re0 | re1) | 601

605
request system autorecovery state
IN THIS SECTION Syntax | 605 Description | 605 Options | 605 Required Privilege Level | 606 Output Fields | 606 Sample Output | 606 Sample Output | 607 Sample Output | 607 Release Information | 608
Syntax
request system autorecovery state (save | recover | clear)
Description
Use this command to prepare the system for autorecovery of configuration, licenses, and disk information.
Options
save Save the current state of the disk partitioning, configuration, and licenses for autorecovery.

606
The active Junos OS configuration is saved as the Junos rescue configuration, after which the rescue configuration, licenses, and disk partitioning information is saved for autorecovery. Autorecovery information must be initially saved using this command for the autorecovery feature to verify integrity of data on every bootup. Any recovery performed at a later stage will restore the data to the same state as it was when the save command was executed. A fresh rescue configuration is generated when the command is executed. Any existing rescue configuration will be overwritten. recover Recover the disk partitioning, configuration, and licenses. After autorecovery data has been saved, the integrity of saved items is always checked automatically on every bootup. The recovery command allows you to forcibly re-run the tests at any time if required. clear Clear all saved autorecovery information. Only the autorecovery information is deleted; the original copies of the data used by the router are not affected. Clearing the autorecovery information also disables all autorecovery integrity checks performed during bootup.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system autorecovery state save
user@host> request system autorecovery state save Saving config recovery information

607
Saving license recovery information Saving bsdlabel recovery information

Sample Output
request system autorecovery state recover

user@host> request system autorecovery state recover

Configuration: File rescue.conf.gz Licenses: File JUNOS282736.lic JUNOS282737.lic BSD Labels: Slice s1 s2 s3 s4

Recovery Information Saved
Recovery Information Saved Saved
Recovery Information Saved Saved Saved Saved

Integrity Check Passed
Integrity Check Passed Failed
Integrity Check Passed Passed Passed Passed

Action / Status None
Action / Status None Recovered
Action / Status None None None None

Sample Output
request system autorecovery state clear
user@host> request system autorecovery state clear Clearing config recovery information
Clearing license recovery information Clearing bsdlabel recovery information

608
Release Information
Command introduced in Junos OS Release 15.1X49-D35.
RELATED DOCUMENTATION show system autorecovery state | 811
request system configuration rescue delete
IN THIS SECTION Syntax | 608 Description | 608 Options | 609 Required Privilege Level | 609 Output Fields | 609 Sample Output | 609 Release Information | 609
Syntax
request system configuration rescue delete
Description
Delete an existing rescue configuration.

609
NOTE: The [edit system configuration] hierarchy is not available on QFabric systems.
Options
This command has no options.
Required Privilege Level
maintenance
Output Fields
This command produces no output.
Sample Output
request system configuration rescue delete
user@host> request system configuration rescue delete
Release Information
Command introduced before Junos OS Release 7.4.

610
request system configuration rescue save
IN THIS SECTION Syntax | 610 Description | 610 Options | 610 Required Privilege Level | 611 Output Fields | 611 Sample Output | 611 Release Information | 611
Syntax
request system configuration rescue save
Description
Save the most recently committed configuration as the rescue configuration so that you can return to it at any time by using the rollback command.
NOTE: The [edit system configuration] hierarchy is not available on QFabric systems.
Options
This command has no options.

611
Required Privilege Level
maintenance
Output Fields
This command produces no output.
Sample Output
request system configuration rescue save
user@host> request system configuration rescue save
Release Information
Command introduced before Junos OS Release 7.4.
request system download abort
IN THIS SECTION Syntax | 612 Description | 612 Options | 612 Required Privilege Level | 612 Output Fields | 612 Sample Output | 613

612
Release Information | 613
Syntax
request system download abort <download-id>
Description
Use this command to terminate a download. The download instance is stopped and cannot be resumed. Any partially downloaded file is automatically deleted to free disk space. Information regarding the download is retained and can be displayed with the show system download command until a request system download clear operation is performed. Downloads in the active, paused, and error states can be terminated.
Options
download-id--(Required) The ID number of the download to be terminated.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.

613
Sample Output
request system download abort
user@host> request system download abort 1 Aborted download #1
Release Information
Command introduced in Junos OS Release 15.1X49-D35.
RELATED DOCUMENTATION request system download start | 619 request system download pause | 615 request system download resume | 617 request system download clear | 613
request system download clear
IN THIS SECTION Syntax | 614 Description | 614 Required Privilege Level | 614 Output Fields | 614 Sample Output | 614 Release Information | 614

614
Syntax
request system download clear
Description
Use this command to delete the history of completed and aborted downloads.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system download clear
user@host> request system download clear Cleared information on completed and aborted downloads
Release Information
Command introduced in Junos OS Release 15.1X49-D35.

615
RELATED DOCUMENTATION request system download start | 619 request system download pause | 615 request system download resume | 617 request system download abort | 611
request system download pause
IN THIS SECTION Syntax | 615 Description | 615 Options | 616 Required Privilege Level | 616 Output Fields | 616 Sample Output | 616 Release Information | 616
Syntax
request system download pause <download-id>
Description
Use this command to suspend a particular download instance. Downloads in the active state can be paused.

616
Options
download-id--(Required) The ID number of the download to be paused.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system download pause
user@host> request system download pause 1 Paused download #1
Release Information
Command introduced in Junos OS Release 15.1X49-D35.
RELATED DOCUMENTATION request system download start | 619 request system download resume | 617 request system download abort | 611 request system download clear | 613

617
request system download resume
IN THIS SECTION Syntax | 617 Description | 617 Options | 617 Required Privilege Level | 618 Output Fields | 618 Sample Output | 618 Release Information | 618
Syntax
request system download resume download-id <max-rate>
Description
Use this command to resume a download that has been paused. You can resume the downloaded instances that are not in progress because of an error or that have been explicitly paused. The file will continue downloading from the point where it paused. By default, the download resumes with the same bandwidth specified with the request system download start command. You can specify a new (maximum) bandwidth with the request system download resume command. Downloads in the paused and error states can be resumed.
Options
download-id--(Required) The ID number of the download to be resumed.

618 max-rate--(Optional) The maximum bandwidth for the download.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system download resume
user@host> request system download resume 1 Resumed download #1
Release Information
Command introduced in Junos OS Release 15.1X49-D35.
RELATED DOCUMENTATION request system download start | 619 request system download pause | 615 request system download abort | 611 request system download clear | 613

619
request system download start
IN THIS SECTION Syntax | 619 Description | 619 Options | 619 Required Privilege Level | 620 Output Fields | 620 Sample Output | 620 Release Information | 620
Syntax
request system download start (sftp-url | delay | identity-file | login | maxrate | passphrase | save as )
Description
Use this command to create a download instance and identify it with a unique integer called the download ID.
Options
sftp-url--(Required) The FTP or HTTP URL location of the file to be downloaded securely. delay--(Optional) The number of hours after which the download should start. Ranges from 1 through 48 hours.

620
identity-file--(Required) The name of the file requesting a Secure FTP (SFTP) download. The SFTP in smart download leverages public key authentication to authenticate a download request. You must generate a private or public key pair before starting a download, and then upload a public key to an SFTP server. login--(Optional) The username and password for the server in the format username:password. max-rate--(Optional) The maximum average bandwidth for the download. Numbers with the suffix k or K, m or M, and g or G are interpreted as Kbps, Mbps, or Gbps, respectively. passphrase--(Required) The passphrase to protect the private key file stored on the file system. This option does not allow the user to enter a weak passphrase, which ensures stronger security. save-as--(Optional) The filename to be used for saving the file in the /var/tmp location.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system download start
user@host> request system download start identity-file mytestkey sftp://mysftpserver/homes/kelly/ test.tgz max-rate 200 save as newfile.tgz Starting download #8
Release Information
Command introduced in Junos OS Release 15.1X49-D35.

621
RELATED DOCUMENTATION request system download pause | 615 request system download resume | 617 request system download abort | 611 request system download clear | 613
request system firmware upgrade
IN THIS SECTION Syntax | 621 Description | 621 Options | 622 Required Privilege Level | 622 Output Fields | 623 Sample Output | 623 Release Information | 623
Syntax
request system firmware upgrade <fpc> <psm> <re>
Description
Use this command to upgrade firmware on a system.

622
Options
fpc Upgrade FPC ROM monitor. · bcm-pfe--(Optional) Upgrade BCM PFE chip. · slot slot-number--(Optional) Upgrade a particular FPC slot.
pic (Junos OS only) Upgrade PIC firmware. psm Upgrade power supply module firmware.
· slot slot-number--(Optional) Upgrade a particular power supply module. re Upgrade baseboard BIOS/FPGA. There is an active BIOS image and a backup BIOS image.
· bios--(Optional) Upgrade BIOS. · fpga--(Optional) Upgrade baseboard FPGA. · i210--(Optional) Upgrade baseboard i210 GbE NIC. · i40nvm--(Optional) Upgrade baseboard i40.
Starting in Junos OS Release 19.3R1, you can upgrade the i40e NVM firmware on routers with VM Host support. · ssd--(Optional) Upgrade Routing Engine solid-state drive (SSD) firmware. · disk1--Upgrade SSD disk1 firmware. · disk2--Upgrade SSD disk2 firmware. Starting in Junos OS Release 17.2R1, you can upgrade the SSD firmware on routers with the VM Host support. · xmcfpga--(Optional) Upgrade XMC FPGA. vcpu--Upgrade VCPU ROM monitor.
Required Privilege Level
maintenance

623
Output Fields
When you enter this command, you are provided feedback on the status of your request.

Sample Output
request system firmware upgrade

user@host> request system firmware upgrade re bios

Part

Type

Tag Current Available Status

version version

Routing Engine 0 RE BIOS

0 1.5

1.9

OK

Routing Engine 0 RE BIOS Backup 1 1.7

1.9

OK

Perform indicated firmware upgrade ? [yes,no] (no) yes

user@host> request system firmware upgrade re bios backup

Part

Type

Tag Current Available Status

version version

Routing Engine 0 RE BIOS

0 1.5

1.9

OK

Routing Engine 0 RE BIOS Backup 1 1.7

1.9

OK

Perform indicated firmware upgrade ? [yes,no] (no) yes

user@host> request system firmware upgrade re ssd disk1

Part Type Tag

Current Available

version version

Routing Engine 0 RE SSD1 4

12028

12029

OK

Perform indicated firmware upgrade ? [yes,no] (no) yes

Status

Firmware upgrade initiated, use "show system firmware" to monitor status.

Release Information
Command introduced in Junos OS Release 10.2.

624
RELATED DOCUMENTATION request system halt
request system halt
IN THIS SECTION Syntax | 624 Description | 624 Options | 625 Required Privilege Level | 625 Output Fields | 625 Sample Output | 625 Release Information | 626
Syntax
request system halt at <time> in <minutes> media (compact-flash | disk | usb) messages <message>
Description
Use this command to stop the system media or messages.

625

Options
at time in minutes media
message message

Time at which to stop the system media or messages. Number of minutes to delay before halting the system media or messages. Boot media for the next boot. · compact-flash-- Standard boot from a flash device. · disk-- Boot from a hard disk. · usb-- Boot from a USB device.
Message that is displayed to all system users before stopping the system media or messages.

Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system halt
user@host> request system halt Halt the system ? [yes,no] (no) yes
*** FINAL System shutdown message from user@host *** System going down IMMEDIATELY

626
Shutdown NOW! [pid 7560] user@host> Dec 8 08:57:37 Waiting (max 60 seconds) for system process `vnlru' to stop...done Waiting (max 60 seconds) for system process `vnlru_mem' to stop...done Waiting (max 60 seconds) for system process `bufdaemon' to stop...done Waiting (max 60 seconds) for system process `syncer' to stop... Syncing disks, vnodes remaining...2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 done syncing disks... All buffers synced. Uptime: 2d16h25m9s recorded reboot as normal shutdown The operating system has halted. Please press any key to reboot.
Release Information
Command introduced in Junos OS Release 11.4.
RELATED DOCUMENTATION request system power-off | 629
request system partition compact-flash
IN THIS SECTION Syntax | 627

627
Description | 627 Required Privilege Level | 627 Output Fields | 627 Sample Output | 628 Sample Output | 628 Release Information | 628
Syntax
request system partition compact-flash
Description
Use this command to reboot the device and repartition the compact flash. The CompactFlash card is repartitioned only if it is possible to restore all the data on the CompactFlash card. Otherwise, the operation is terminated, and a message is displayed indicating that the current disk usage needs to be reduced.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.

628
Sample Output
request system partition compact-flash (If Yes)
user@host> request system partition compact-flash Are you sure you want to reboot and partition the compact-flash ? [yes,no] yes Initiating repartition operation. The operation may take several minutes to complete. System will reboot now... <System reboots> <Repartition operation is performed> <System reboots and starts up normally>
Sample Output
request system partition compact-flash (If No)
user@host> request system partition compact-flash Are you sure you want to reboot and partition the compact-flash ? [yes,no] no
Release Information
Command introduced in Junos OS Release 9.2. Command deprecated for Junos OS with Upgraded FreeBSD in Junos OS Release 15.1.
NOTE: To determine which platforms run Junos OS with Upgraded FreeBSD, see the table listing the platforms currently running Junos OS with upgraded FreeBSD in Release Information for Junos OS with Upgraded FreeBSD.

629
request system power-off
IN THIS SECTION Syntax | 629 Description | 629 Options | 630 Required Privilege Level | 630 Output Fields | 630 Sample Output | 631 Release Information | 631
Syntax
request system power-off at <time> in <minutes> junos message <message> network oam power-off usb media (compact-flash | disk | usb | internal)
Description
Use this command to power off the system.

630

Options

at time

Time at which to power off the system.

in minutes

Number of minutes to delay before powering off the system.

media

Boot media for the next boot.

· compact-flash-- Standard boot from a flash device.

· disk-- Boot from a hard disk.

· usb-- Boot from a USB device.

· internal-- Boot from internal flash.

message message Message that is displayed to all system users before powering off the system.

junos

(SRX1500, SRX5400, SRX5600, and SRX5800) Boot off Junos volume.

network

(SRX1500, SRX5400, SRX5600, and SRX5800) Network boot through PXE.

oam

(SRX1500, SRX5400, SRX5600, and SRX5800) Boot off OAM volume.

usb

(SRX1500, SRX5400, SRX5600, and SRX5800) Boot off USB device.

power-off

(SRX1500) Power off the software on RE.

Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.

631
Sample Output
request system power-off
user@host> request system power-off Power Off the system ? [yes,no] (no) yes Shutdown NOW! [pid 3300]
*** FINAL System shutdown message from user@host *** System going down IMMEDIATELY
user@host> Dec 8 09:37:45 Waiting (max 60 seconds) for system process `vnlru' to stop...done Waiting (max 60 seconds) for system process `vnlru_mem' to stop...done Waiting (max 60 seconds) for system process `bufdaemon' to stop...done Waiting (max 60 seconds) for system process `syncer' to stop... Syncing disks, vnodes remaining...2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 done syncing disks... All buffers synced. Uptime: 38m33s recorded reboot as normal shutdown The operating system has halted. Turning the system power off.
Release Information
Command introduced in Junos OS Release 11.4.

632
RELATED DOCUMENTATION request system halt | 624
request system reboot
IN THIS SECTION Syntax | 632 Syntax (EX Series Switches and EX Series Virtual Chassis) | 633 Syntax (MX Series Routers and MX Series Virtual Chassis, EX9200 Switches and EX9200 Virtual Chassis) | 633 Syntax (QFabric Systems) | 633 Syntax (QFX Series Switches and QFX Series Virtual Chassis, Virtual Chassis Fabric) | 634 Syntax (TX Matrix Router) | 634 Syntax (TX Matrix Plus Router) | 635 Description | 635 Options | 635 Additional Information | 639 Required Privilege Level | 639 Output Fields | 640 Sample Output | 640 Release Information | 642
Syntax
request system reboot <at time> <both-routing-engines> <in minutes> <media (compact-flash | disk | removable-compact-flash | usb)>

633
<message "text"> <other-routing-engine>
Syntax (EX Series Switches and EX Series Virtual Chassis)
request system reboot <all-members | local | member member-id> <at time> <in minutes> <media (external | internal)> | <media (compact-flash | disk | removable-compactflash | usb)> <message "text"> <slice slice>
Syntax (MX Series Routers and MX Series Virtual Chassis, EX9200 Switches and EX9200 Virtual Chassis)
request system reboot <all-members | local | member member-id> <at time> <both-routing-engines> <in minutes> <media (external | internal)> | <media (compact-flash | disk | usb)> | <junos | network | oam | usb> <message "text"> <other-routing-engine>
Syntax (QFabric Systems)
request system reboot <all <graceful>> <at time>

634
<director-device name> <director-group <graceful>> <fabric <graceful>> <in minutes> <in-service> <media> <message "text"> <node-group name> <slice slice>

Syntax (QFX Series Switches and QFX Series Virtual Chassis, Virtual Chassis Fabric)
request system reboot <all-members | local | member member-id> <at time> <in minutes> <in-service> <hypervisor> <junos | network | oam | usb> <message "text"> <slice slice>

Syntax (TX Matrix Router)

request system reboot <all-chassis | all-lcc | lcc number | <at time> <both-routing-engines> <in minutes> <media (compact-flash | disk)> <message "text"> <other-routing-engine>

scc>

635
Syntax (TX Matrix Plus Router)
request system reboot <all-chassis | all-lcc | lcc number | sfc number> <at time> <both-routing-engines> <in minutes> <media (compact-flash | disk)> <message "text"> <other-routing-engine> <partition (1 | 2 | alternate)>
Description
Use this command to reboot the device software. This command can be used on standalone devices and on devices supported in a Virtual Chassis, Virtual Chassis Fabric, or QFabric system. Starting with Junos OS Release 15.1F3, the statement request system reboot reboots only the guest operating system on the PTX5000 with RE-PTX-X8-64G and, MX240, MX480, and MX960 with RE-SX6-64G. Starting with Junos OS Release 15.1F5, the statement request system reboot reboots only the guest operating system on the MX2010, and MX2020 with REMX2K-X8-64G. Starting from Junos OS Release 17.2R1, PTX10008 routers do not support the request system reboot command. Starting from Junos OS Release 17.4R1, PTX10016 routers do not support the request system reboot command. Use the request vmhost reboot command instead of the request system reboot command on the PTX10008 and PTX10016 routers to reboot the Junos OS software package or bundle on the router. See request vmhost reboot. On a QFabric system, to avoid traffic loss on the network Node group, switch mastership of the Routing Engine to the backup Routing Engine, and then reboot.
Options
The options described here are not all supported on every platform or release of Junos OS. Refer to the Syntax sections for the options commonly available on each type of platform.

636

none

Reboot the software immediately.

all-chassis

(Optional) On a TX Matrix router or TX Matrix Plus router, reboot all routers connected to the TX Matrix or TX Matrix Plus router, respectively.

all-lcc

(Optional) On a TX Matrix router or TX Matrix Plus router, reboot all line card chassis connected to the TX Matrix or TX Matrix Plus router, respectively.

all-members | local | member member-id

(Optional) Specify which member of the Virtual Chassis to reboot: · all-members--Reboots each switch that is a member of the Virtual Chassis.

· local--Reboots only the local switch (switch where you are logged in).

· member member-id--Reboots the specified member switch of the Virtual Chassis

at time

(Optional) Time at which to reboot the software, specified in one of the following ways:
· now--Stop or reboot the software immediately. This is the default.

· +minutes--Number of minutes from now to reboot the software.

· yymmddhhmm--Absolute time at which to reboot the software, specified as year, month, day, hour, and minute.

· hh:mm--Absolute time on the current day at which to stop the software, specified in 24-hour time.

both-routingengines hypervisor

(Optional) Reboot both Routing Engines at the same time. (Optional) Reboot Junos OS, host OS, and any installed guest VMs.

in minutes

(Optional) Number of minutes from now to reboot the software. The minimum value is 1. This option is an alias for the at +minutes option.

in-service

(Optional) Enables you to reset the software state (no software version change) of the system with minimal disruption in data and control traffic.

junos

(Optional) Reboot from the Junos OS (main) volume.

lcc number

--(Optional) Line-card chassis (LLC) number. Replace number with the following values depending on the LCC configuration:

637

· 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

· 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

· 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

· 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

media (compact-flash | disk | removablecompact-flash | usb) media (external | internal)

(Optional) Use the indicated boot medium for the next boot.
(Optional) Use the indicated boot medium for the next boot: · external--Reboot the device using a software package stored on an external boot
source, such as a USB flash drive.

· internal--Reboot the device using a software package stored in an internal memory source.

message "text" (Optional) Message to display to all system users before stopping or rebooting the software.

network

(Optional) Reboot using the Preboot Execution Environment (PXE) boot method over the network.

oam

(Optional) Reboot from the maintenance volume (OAM volume, usually the compact

flash drive).

other-routingengine

(Optional) Reboot the other Routing Engine from which the command is issued. For example, if you issue the command from the primary Routing Engine, the backup Routing Engine is rebooted. Similarly, if you issue the command from the backup Routing Engine, the primary Routing Engine is rebooted.

partition partition

(Optional) Reboot using the specified partition on the boot media. This option is equivalent to the slice option that is supported on some devices. Specify one of the following partition values:
· 1--Reboot from partition 1.

638

scc sfc number slice slice

· 2--Reboot from partition 2.
· alternate--Reboot from the alternate partition.
(Optional) Reboot the Routing Engine on the TX Matrix switch-card chassis. If you issue the command from re0, re0 is rebooted. If you issue the command from re1, re1 is rebooted.
(Optional) Reboot the Routing Engine on the TX Matrix Plus switch-fabric chassis. If you issue the command from re0, re0 is rebooted. If you issue the command from re1, re1 is rebooted. Replace number with 0.
(Optional) Reboot using the specified partition on the boot media. This option was originally the partitiion option but was renamed to slice on EX Series and QFX Series switches. Specify one of the following slice values:
· 1--Reboot from partition 1.
· 2--Reboot from partition 2.
· alternate--Reboot from the alternate partition (which did not boot the switch at the last bootup).

NOTE: The slice option is not supported on QFX Series switches that have no alternate slice when Junos OS boots as a Virtual Machine (VM). To switch to the previous version of Junos OS, issue the request system software rollback command.

usb

(Optional) Reboot from a USB device.

The following options are available only on QFabric Systems:

all

(Optional) Reboots the software on the Director group, fabric control Routing Engines,

fabric manager Routing Engines, Interconnect devices, and network and server Node

groups.

director-device (Optional) Reboots the software on the Director device and the default partition

name

(QFabric CLI).

director-group

(Optional) Reboots the software on the Director group and the default partition (QFabric CLI).

fabric

(Optional) Reboots the fabric control Routing Engines and the Interconnect devices.

639

node-group name graceful

(Optional) Reboots the software on a server Node group or a network Node group.
(Optional) Enables the QFabric component to reboot with minimal impact to network traffic. This sub-option is only available for the all, fabric, anddirector-group options.

Additional Information
Reboot requests are recorded in the system log files, which you can view with the show log command (see show log). Also, the names of any running processes that are scheduled to be shut down are changed. You can view the process names with the show system processes command (see show system processes).
On a TX Matrix or TX Matrix Plus router, if you issue the request system reboot command on the primary Routing Engine, all the primary Routing Engines connected to the routing matrix are rebooted. If you issue this command on the backup Routing Engine, all the backup Routing Engines connected to the routing matrix are rebooted.
NOTE: Before issuing the request system reboot command on a TX Matrix Plus router with no options or the all-chassis, all-lcc, lcc number, or sfc options, verify that primary Routing Engine for all routers in the routing matrix are in the same slot number. If the primary Routing Engine for a line-card chassis is in a different slot number than the primary Routing Engine for a TX Matrix Plus router, the line-card chassis might become logically disconnected from the routing matrix after the request system reboot command.
NOTE: To reboot a router that has two Routing Engines, reboot the backup Routing Engine (if you have upgraded it) first, and then reboot the primary Routing Engine.

Required Privilege Level
maintenance

640
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system reboot
user@host> request system reboot Reboot the system ? [yes,no] (no)
request system reboot (at 2300)
user@host> request system reboot at 2300 message ?Maintenance time!? Reboot the system ? [yes,no] (no) yes shutdown: [pid 186] *** System shutdown message from root@test.example.net *** System going down at 23:00
request system reboot (in 2 Hours) The following example, which assumes that the time is 5 PM (17:00), illustrates three different ways to request the system to reboot in two hours:
user@host> request system reboot at +120 user@host> request system reboot in 120 user@host> request system reboot at 19:00
request system reboot (Immediately)
user@host> request system reboot at now

641
request system reboot (at 1:20 AM) To reboot the system at 1:20 AM, enter the following command. Because 1:20 AM is the next day, you must specify the absolute time.
user@host> request system reboot at 06060120 request system reboot at 120 Reboot the system at 120? [yes,no] (no) yes

request system reboot in-service

user@switch> request system reboot in-service Reboot the system ? [yes,no] [Feb 22 02:37:04]:ISSU: Validating Image

PRE ISSR CHECK: --------------PFE Status Member Id zero VC not in mixed or fabric mode Member is single node vc BFD minimum-interval check done GRES enabled NSR enabled drop-all-tcp not configured Ready for ISSR

: Online : Valid : Valid : Valid : Valid : Valid : Valid : Valid : Valid

warning: Do NOT use /user during ISSR. Changes to /user during ISSR may get lost! Current image is jinstall-jcp-i386-flex-18.1.img [Feb 22 02:37:14]:ISSU: Preparing Backup RE Prepare for ISSR [Feb 22 02:37:19]:ISSU: Backup RE Prepare Done Spawning the backup RE Spawn backup RE, index 1 successful Starting secondary dataplane Second dataplane container started GRES in progress Waiting for backup RE switchover ready

642

GRES operational

Copying home directories

Copying home directories successful

Initiating Chassis In-Service-Upgrade for ISSR

Chassis ISSU Started

[Feb 22 02:42:55]:ISSU: Preparing Daemons

[Feb 22 02:43:00]:ISSU: Daemons Ready for ISSU

[Feb 22 02:43:05]:ISSU: Starting Upgrade for FRUs

[Feb 22 02:43:15]:ISSU: FPC Warm Booting

[Feb 22 02:44:16]:ISSU: FPC Warm Booted

[Feb 22 02:44:27]:ISSU: Preparing for Switchover

[Feb 22 02:44:31]:ISSU: Ready for Switchover

Checking In-Service-Upgrade status

Item

Status

Reason

FPC 0

Online (ISSU)

Send ISSR done to chassisd on backup RE

Chassis ISSU Completed

Removing dcpfe0 eth1 128.168.0.16 IP

Bringing down bme00

Post Chassis ISSU processing done

[Feb 22 02:44:33]:ISSU: IDLE

Stopping primary dataplane

Clearing ISSU states

Console and management sessions will be disconnected. Please login again.

device_handoff successful ret: 0

Shutdown NOW!

[pid 14305]

*** FINAL System shutdown message from root@sw-duckhorn-01 ***

System going down IMMEDIATELY

Release Information
Command introduced before Junos OS Release 7.4. Option other-routing-engine introduced in Junos OS Release 8.0. Option sfc introduced for the TX Matrix Plus router in Junos OS Release 9.6. Option partition changed to slice in Junos OS Release 10.0 for EX Series switches.

643
Option both-routing-engines introduced in Junos OS Release 12.1.
RELATED DOCUMENTATION clear system reboot request system halt Routing Matrix with a TX Matrix Plus Router Solutions Page request vmhost reboot
request system reboot (Junos OS with Upgraded FreeBSD)
IN THIS SECTION Syntax | 643 Description | 644 Options | 644 Additional Information | 645 Required Privilege Level | 645 Output Fields | 645 Sample Output | 646 Release Information | 647
Syntax
request system reboot <at time> <both-routing-engines> <in minutes> <junos>

644
<message "text"> <network> <oam> <other-routing-engine> <usb>

Description
Use this command to reboot the device software.

Options

none

Reboot the device software immediately.

at time

(Optional) Time at which to reboot the software, specified in one of the following ways: · now--Stop or reboot the software immediately. This is the default.

· +minutes--Number of minutes from now to reboot the software.

· yymmddhhmm--Absolute time at which to reboot the software, specified as year, month, day, hour, and minute. Omitting a value will default to the current date for that value.

· hh:mm--Absolute time on the current day at which to stop the software, specified in 24-hour time.

both-routingengines in minutes

(Optional) Reboot both Routing Engines at the same time.
(Optional) Number of minutes from now to reboot the software. This option is an alias for the at +minutes option.

junos

(Optional) Reboot from the junos volume.

message "text"

(Optional) Message to display to all system users before stopping or rebooting the software.

network

(Optional) Reboot from the network.

oam

(Optional) Reboot from the oam volume.

645

otherroutingengine usb

(Optional) Reboot the other Routing Engine from which the command is issued. For example, if you issue the command from the primary Routing Engine, the backup Routing Engine is rebooted. Similarly, if you issue the command from the backup Routing Engine, the primary Routing Engine is rebooted.
(Optional) Reboot from the USB device.

Additional Information
Reboot requests are recorded in the system log files, which you can view with the show log command (see show log). Also, the names of any running processes that are scheduled to be shut down are changed. You can view the process names with the show system processes command (see show system processes).
NOTE: To reboot a router or switch that has two Routing Engines, reboot the backup Routing Engine (if you have upgraded it) first, and then reboot the primary Routing Engine.

Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.

646
Sample Output
request system reboot
user@host> request system reboot Reboot the system ? [yes,no] (no)
request system reboot (at 2300)
user@host> request system reboot at 2300 message "Maintenance time!" Reboot the system ? [yes,no] (no) yes shutdown: [pid 186] *** System shutdown message from root@berry.network.net *** System going down at 23:00
request system reboot (in 2 Hours)
The following example, which assumes that the time is 5 PM (17:00), illustrates three different ways to request the system to reboot in two hours:
user@host> request system reboot at +120 user@host> request system reboot in 120 user@host> request system reboot at 19:00
request system reboot (Immediately)
user@host> request system reboot at now
request system reboot (at 1:20 AM)
To reboot the system at 1:20 AM, enter the following command. Because 1:20 AM is the next day, you must specify the absolute time.
user@host> request system reboot at 06060120

647
request system reboot at 120 Reboot the system at 120? [yes,no] (no) yes
Release Information
Command introduced in Junos OS Release 15.1.
RELATED DOCUMENTATION request system snapshot (Junos OS with Upgraded FreeBSD) | 668 show system snapshot (Junos OS with Upgraded FreeBSD) | 838 clear system reboot request system halt Release Information for Junos OS with Upgraded FreeBSD
request system recover
IN THIS SECTION Syntax | 648 Description | 648 Options | 648 Additional Information | 648 Required Privilege Level | 649 Sample Output | 649 Release Information | 650

648
Syntax
request system recover (junos-volume | oam-volume)

Description
Use this command to recover a specified volume of the system. Guest network functions (GNFs) do not support the recover option under the request system command. See Components of Junos Node Slicing for more details on GNF.

Options

junosvolume oamvolume

Specify the /junos volume to be recovered. The /junos volume is the main drive and contains all the software and files needed for the day-to-day running of the device, including configuration information and logs. The/junos volume also contains non-recovery snapshots, which are new with Junos OS with upgraded FreeBSD. Non-recovery snapshots cannot be used for recovery of a failed system.
Specify the /oam volume to be recovered. The compact flash drive is the /oam volume and stores recovery snapshot backup information. In case of failure of the /junos volume, the /oam volume can be used to boot the system. The /oam volume has the recovery snapshot, which is created with the request system snapshot recovery command. A recovery snapshot is always replaced when a new recovery snapshot is taken.

Additional Information
If you try to recover the /junos volume while you are booted on the /junos volume, you will get an error message. To recover the /junos volume, do the following:

649
1. Recover the /oam volume.
user@host> request system recover oam-volume
2. Reboot on the /oam volume.
user@host> request system reboot oam-volume
Required Privilege Level
view
Sample Output
request system recover junos-volume (While booted on the /junos volume)
user@host> request system recover junos-volume ERROR: You are currently running on the Junos volume ERROR: A recovery of the Junos volume is not possible
request system recover junos-volume (While booted on the /oam volume)
user@host> request system recover junos-volume NOTICE: Recovering the Junos volume ... ada0p3 deleted ada0 created ada0p1 added bootcode written to ada0 ada0p3 added ada0p2 added /dev/gpt/junos: 20303.9MB (41582448 sectors) block size 32768, fragment size 4096
using 33 cylinder groups of 626.22MB, 20039 blks, 80256 inodes. super-block backups (for fsck_ffs -b #) at:
192, 1282688, 2565184, 3847680, 5130176, 6412672, 7695168, 8977664, 10260160,

650
11542656, 12825152, 14107648, 15390144, 16672640, 17955136, 19237632, 20520128, 21802624, 23085120, 24367616, 25650112, 26932608, 28215104, 29497600, 30780096, 32062592, 33345088, 34627584, 35910080, 37192576, 38475072, 39757568, 41040064 NOTICE: Junos volume recovered
request system recover oam-volume
user@host> request system recover oam-volume NOTICE: Recovering the OAM volume ... ada1p2 deleted ada1 created ada1p1 added bootcode written to ada1 ada1p2 added /dev/gpt/oam: 3831.6MB (7847136 sectors) block size 32768, fragment size 4096
using 7 cylinder groups of 626.09MB, 20035 blks, 80256 inodes. super-block backups (for fsck_ffs -b #) at:
192, 1282432, 2564672, 3846912, 5129152, 6411392, 7693632 Verified oam signed by PackageProductionEc_2017 method ECDSA256+SHA256 Installing OAM volume contents ... The OAM volume is now installed NOTICE: Creating a recovery snapshot on the OAM volume ... Creating image ... Compressing image ... Image size is 1717MB Recovery snapshot created successfully NOTICE: OAM volume recovered
Release Information
Command introduced in Junos OS Release 15.1.
RELATED DOCUMENTATION Release Information for Junos OS with Upgraded FreeBSD Changes in Disk Volumes for Junos OS with Upgraded FreeBSD

651 Changes in Use of Snapshots for Junos OS with Upgraded FreeBSD
request system scripts add
IN THIS SECTION Syntax | 651 Description | 651 Options | 651 Required Privilege Level | 652 Release Information | 652
Syntax
request system scripts add <package-name> <no-copy> <unlink>
Description
Use this command to install AI-Script (jais) packages on Juniper Networks devices.
Options
no-copy Don't save a copy of the jais package file. user@host> request system scripts add no-copy <package-name>

652

unlink

If you use the no-copy option during the jais installation, the jais package cannot be rolled back.
Remove the package after successful installation.

user@host> request system scripts add unlink <package-name>

Required Privilege Level
maintenance
Release Information
Command introduced before Junos OS Release 9.0.
RELATED DOCUMENTATION request system scripts delete | 652 request system scripts rollback | 654 request system scripts event-scripts reload
request system scripts delete
IN THIS SECTION Syntax | 653 Description | 653 Options | 653 Required Privilege Level | 653

653
Release Information | 653
Syntax
request system scripts delete <package-name>
Description
Use this command to delete AI-Script (jais) packages on Juniper Networks devices.
Options
No options are available.
Required Privilege Level
maintenance
Release Information
Command introduced before Junos OS Release 9.0.
RELATED DOCUMENTATION request system scripts add | 651 request system scripts rollback | 654 request system scripts event-scripts reload

654
request system scripts rollback
IN THIS SECTION Syntax | 654 Description | 654 Options | 654 Required Privilege Level | 654 Release Information | 655
Syntax
request system scripts rollback
Description
Use this command to roll back to most recent installation of AI-Scripts (jais) package.
Options
No options are available.
Required Privilege Level
maintenance

655
Release Information
Command introduced before Junos OS Release 9.0.
RELATED DOCUMENTATION request system scripts add | 651 request system scripts delete | 652 request system scripts event-scripts reload
request system snapshot
IN THIS SECTION Syntax (ACX Series Routers) | 656 Syntax (EX Series Switches; for EX4600, see QFX Series Syntax) | 656 Syntax (MX Series Routers) | 656 Syntax (PTX Series) | 656 Syntax (QFX Series, OCX1100, and EX4600) | 657 Syntax (TX Matrix Routers) | 657 Syntax (TX Matrix Plus Routers) | 657 Description | 657 Options | 658 Additional Information | 662 Required Privilege Level | 662 Output Fields | 662 Sample Output | 662 Release Information | 668

656
Syntax (ACX Series Routers)
request system snapshot <media type> <partition>
Syntax (EX Series Switches; for EX4600, see QFX Series Syntax)
request system snapshot <all-members | local | member member-id> <media type> <partition> <re0 | re1 | routing-engine routing-engine-id> <slice alternate>
Syntax (MX Series Routers)
request system snapshot <all-members> <config-partition> <local> <member member-id> <media usb-port-number> <partition> <root-partition>
Syntax (PTX Series)
request system snapshot <partition>

657
Syntax (QFX Series, OCX1100, and EX4600)
request system snapshot <all-members | local | member member-id> <config-partition> <partition> <root-partition> <slice alternate>

Syntax (TX Matrix Routers)

request system snapshot <all-chassis | all-lcc | lcc number | <config-partition> <partition> <root-partition>

scc>

Syntax (TX Matrix Plus Routers)

request system snapshot <all-chassis | all-lcc | lcc number | <config-partition> <partition> <root-partition>

sfc number>

Description
· On routers running Junos OS, back up the currently running and active file system partitions to standby partitions that are not running. Specifically, the root file system (/) is backed up to /altroot, and /config is backed up to /altconfig. The root and /config file systems are on the router's flash drive, and the /altroot and /altconfig file systems are on the router's hard drive.

658
· On switches running Junos OS, take a snapshot of the files currently used to run the switch--the complete contents of the root (/) , /altroot, /config, /var, and /var-tmp directories, which include the running version of Junos OS, the active configuration, and log files.
· On devices running Junos OS Evolved, take a snapshot of the contents of the /soft directory, which includes the running version of Junos OS Evolved.
System snapshot is not supported on QFX10000 and QFX5110-48s-4c switches.
Starting with Junos OS Release 15.1F3, the command request system snapshot creates a snapshot of the guest OS image only for the PTX5000 with RE-DUO-C2600-16G, and the MX240, MX480, and MX960 routers with RE-S-1800X4-32G-S.
Starting with Junos OS Release 15.1F5, the command request system snapshot creates a snapshot of the guest OS image only for the MX2010 and MX2020 routers with REMX2K-1800-32G-S.
On these routers, in order to create snapshot of the host OS image along with Junos OS image, use the request vmhost snapshot command.
CAUTION: After you run the request system snapshot command, you cannot return to the previous version of the software, because the running and backup copies of the software are identical.

Options

The specific options available depend upon the router or switch:

none

Back up the currently running software as follows:

· On the router, back up the currently running and active file system partitions to standby partitions that are not running. Specifically, the root file system (/) is backed up to /altroot, and /config is backed up to /altconfig. The root and /config file systems are on the router's flash drive, and the /altroot and /altconfig file systems are on the router's hard drive.

· On the switch, take a snapshot of the files currently used to run the switch and copy them to the media that the switch did not boot from. If the switch is booted from internal media, the snapshot is copied to external (USB) media. If the switch is booted from external (USB) media, the snapshot is copied to internal media.

659

· If the snapshot destination is external media but a USB flash drive is not connected, an error message is displayed.

· If the automatic snapshot procedure is already in progress, the command returns the following error: Snapshot already in progress. Cannot start manual snapshot. For additional information about the automatic snapshot feature, see "Configuring Dual-Root Partitions" on page 365.

all-chassis | all-lcc | lcc number

(TX Matrix and TX Matrix Plus router only) (Optional)
· all-chassis--On a TX Matrix router, archive data and executable areas for all Routing Engines in the chassis. On a TX Matrix Plus router, archive data and executable areas for all Routing Engines in the chassis.

· all-lcc--On a TX Matrix router, archive data and executable areas for all T640 routers (or line-card chassis) connected to a TX Matrix router. On a TX Matrix Plus router, archive data and executable areas for all routers (or line-card chassis) connected to a TX Matrix Plus router.

· lcc number--On a TX Matrix router, archive data and executable areas for a specific T640 router (or line-card chassis) that is connected to a TX Matrix router. On a TX Matrix Plus router, archive data and executable areas for a specific router (line-card chassis) that is connected to a TX Matrix Plus router.
Replace number with the following values depending on the LCC configuration:
· 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

· 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

· 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

· 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

all-members | local | member member-id

(EX Series Virtual Chassis, MX Series routers, QFX Series switches, QFabric System, and OCX1100 only) (Optional) Specify where to place the snapshot (archive data and executable areas) in a Virtual Chassis:

· all-members--Create a snapshot (archive data and executable areas) for all members of the Virtual Chassis.

660

· local--Create a snapshot (archive data and executable areas) on the member of the Virtual Chassis that you are currently logged into.

· member member-id--Create a snapshot (archive data and executable areas) for the specified member of the Virtual Chassis.

configpartition

(EX Series Virtual Chassis, MX Series routers, QFX Series switches, QFabric System, OCX1100, and T and TX Series routers only) Create a snapshot of the configuration partition only and store it onto the default /altconfig on the hard disk device or an / altconfig on a USB device. Option deprecated for Junos OS with Upgraded FreeBSD in Junos OS Release 15.1.
To determine which platforms support Junos OS with upgraded FreeBSD, see Feature Explorer and enter one of the following:
· For non-virtualized, enter freebsd and select Junos kernel upgrade to FreeBSD 10+.

· For virtualized, enter virtualization and select Virtualization of the Routing Engine.

media type

(ACX Series, M320, T640, and MX Series routers) (Optional) Specify the boot device the software is copied to:

· compact-flash--Copy software to the primary compact flash drive.

· external--(Switches only) Copy software to an external mass storage device, such as a USB flash drive. If a USB drive is not connected, the switch displays an error message.

· internal--Copy software to an internal flash drive.

· removable-compact-flash--Copy software to the removable compact flash drive.

· usb--(ACX Series, M320, T640, and, except for MX104, MX Series routers) Copy software to the device connected to the USB port.

· usb0--(MX104 routers only) Copy software to the device connected to the USB0 port.

· usb1--(MX104 routers only) Copy software to the device connected to the USB1 port.

partition

(Optional) Repartition the flash drive before a snapshot occurs. If the partition table on the flash drive is corrupted, the request system snapshot command fails and reports errors. The partition option is only supported for restoring the software image from the hard drive to the flash drive.

661

(Routers only) You cannot issue the request system snapshot command when you enable flash disk mirroring. We recommend that you disable flash disk mirroring when you upgrade or downgrade the software.
(EX Series switches only) If the snapshot destination is the media that the switch did not boot from, you must use the partition option.

re0 | re1 | routingengine routingengine-id

(EX6200 and EX8200 switches only) Specify where to place the snapshot in a redundant Routing Engine configuration.
· re0--Create a snapshot on Routing Engine 0.
· re1--Create a snapshot on Routing Engine 1.

· routing-engine routing-engine-id--Create a snapshot on the specified Routing Engine.

rootpartition

(M, MX, T, and TX Series routers; EX Series Virtual Chassis; QFX Series switches; QFabric System; and OCX1100 only) Create a snapshot of the root partition only and store it onto the default /altroot on the hard disk device or an /altroot on a USB device. Option deprecated for Junos OS with Upgraded FreeBSD in Junos OS Release 15.1.
To determine which platforms run Junos OS with Upgraded FreeBSD, see the information in Release Information for Junos OS with Upgraded FreeBSD.

slice alternate

(EX Series switches, EX Series Virtual Chassis, QFX Series switches, QFabric System, and OCX1100 only) (Optional) Take a snapshot of the active root partition and copy it to the alternate slice on the boot media.
Option deprecated for Junos OS with Upgraded FreeBSD in Junos OS Release 15.1.
To determine which platforms support Junos OS with upgraded FreeBSD, see Feature Explorer and enter one of the following:
· For non-virtualized, enter freebsd and select Junos kernel upgrade to FreeBSD 10+.

· For virtualized, enter virtualization and select Virtualization of the Routing Engine.

scc

(TX Matrix router only) (Optional) Archive data and executable areas for a TX Matrix

router (or switch-card chassis).

sfc number (TX Matrix Plus router only) (Optional) Archive data and executable areas for a TX Matrix Plus router (or switch-fabric chassis). Replace number with 0.

662
Additional Information
· (Routers only) Before you upgrade the software on the router, when you have a known stable system, issue the request system snapshot command to back up the software, including the configuration, to the /altroot and /altconfig file systems. After you have upgraded the software on the router and are satisfied that the new packages are successfully installed and running, issue the request system snapshot command again to back up the new software to the /altroot and /altconfig file systems.
· (Routers only) You cannot issue the request system snapshot command when you enable flash disk mirroring. We recommend that you disable flash disk mirroring when you upgrade or downgrade the software.
· (TX Matrix and TX Matrix Plus router only) On a routing matrix, if you issue the request system snapshot command on the primary Routing Engine, all the primary Routing Engines connected to the routing matrix are backed up. If you issue this command on the backup Routing Engine, all the backup Routing Engines connected to the routing matrix are backed up.
Required Privilege Level
view
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system snapshot (Routers)
user@host> request system snapshot umount: /altroot: not currently mounted Copying / to /altroot.. (this may take a few minutes) umount: /altconfig: not currently mounted Copying /config to /altconfig.. (this may take a few minutes)

663

The following filesystems were archived: / /config

request system snapshot (EX Series Switches)

user@switch> request system snapshot partition Clearing current label... Partitioning external media (/dev/da1) ... Partitions on snapshot:

Partition Mountpoint Size Snapshot argument

s1a /altroot 179M none

s2a /

180M none

s3d /var/tmp 361M none

s3e /var

121M none

s4d /config

60M

none

Copying '/dev/da0s1a' to '/dev/da1s1a' .. (this may take a few minutes)

Copying '/dev/da0s2a' to '/dev/da1s2a' .. (this may take a few minutes)

Copying '/dev/da0s3d' to '/dev/da1s3d' .. (this may take a few minutes)

Copying '/dev/da0s3e' to '/dev/da1s3e' .. (this may take a few minutes)

Copying '/dev/da0s4d' to '/dev/da1s4d' .. (this may take a few minutes)

The following filesystems were archived: /altroot / /var/tmp /var /config

request system snapshot partition (EX4600, QFX Series, QFabric System, and OCX1100)

user@switch> request system snapshot partition Clearing current label... Partitioning external media (da1) ... Verifying compatibility of destination media partitions... Running newfs (334MB) on external media / partition ... Running newfs (404MB) on external media /config partition ... Running newfs (222MB) on external media /var partition ... Copying '/dev/da0s2a' to '/dev/da1s1a' .. (this may take a few minutes) Copying '/dev/da0s3e' to '/dev/da1s3e' .. (this may take a few minutes) Copying '/dev/da0s2f' to '/dev/da1s1f' .. (this may take a few minutes) The following filesystems were archived: / /config /var

664
request system snapshot (When the Partition Flag Is On)
user@host> request system snapshot partition Performing preliminary partition checks ... Partitioning ad0 ... umount: /altroot: not currently mounted Copying / to /altroot.. (this may take a few minutes)
The following filesystems were archived: / /config
request system snapshot (MX104 Routers When Media Device is Missing)
user@host > request system snapshot media usb0 error: usb0 media missing or invalid
request system snapshot (When Mirroring Is Enabled)
user@host> request system snapshot Snapshot is not possible since mirror-flash-on-disk is configured.
request system snapshot all-lcc (Routing Matrix)
user@host> request system snapshot all-lcc lcc0-re0: -------------------------------------------------------------------------Copying '/' to '/altroot' .. (this may take a few minutes) Copying '/config' to '/altconfig' .. (this may take a few minutes) The following filesystems were archived: / /config
lcc2-re0: -------------------------------------------------------------------------Copying '/' to '/altroot' .. (this may take a few minutes) Copying '/config' to '/altconfig' .. (this may take a few minutes) The following filesystems were archived: / /config

665
request system snapshot all-members (Virtual Chassis)
user@switch> request system snapshot all-members media internal
fpc0: -------------------------------------------------------------------------Copying '/dev/da0s2a' to '/dev/da0s1a' .. (this may take a few minutes) The following filesystems were archived: /
fpc1: -------------------------------------------------------------------------Copying '/dev/da0s2a' to '/dev/da0s1a' .. (this may take a few minutes) The following filesystems were archived: /
fpc2: -------------------------------------------------------------------------Copying '/dev/da0s2a' to '/dev/da0s1a' .. (this may take a few minutes) The following filesystems were archived: /
fpc3: -------------------------------------------------------------------------Copying '/dev/da0s2a' to '/dev/da0s1a' .. (this may take a few minutes) The following filesystems were archived: /
fpc4: -------------------------------------------------------------------------Copying '/dev/da0s2a' to '/dev/da0s1a' .. (this may take a few minutes) The following filesystems were archived: /
fpc5: -------------------------------------------------------------------------Copying '/dev/da0s2a' to '/dev/da0s1a' .. (this may take a few minutes) The following filesystems were archived: /
request system snapshot (Junos OS Evolved)
user@host> request system snapshot ------------------------------node: re0 -------------------------------

666
Snapshot device found - /dev/sdb System is up for 29 minutes, proceed and initiate snapshot Creating snapshot mount dirs in /tmp/snapshot Creating snapshot disk filesystems and mounts sfdisk: failed to dump partition table: Success Found 186 gig (195360984 kbytes) Vendor ATA, Model XXXXXXXXXXXXXXXWriting new partitioning table to disk sdb -
boot - 204800K soft - 16384M swap - 4096M data - 3072M conf - 1024M var - 166006M user - 0M Done New Partitions - rebuilding filesystems Error: Could not stat device sdb - No such file or directory. Processing /dev/sdb2 for mount on /tmp/snapshot/soft ... [creating]..ok [mounting]..done Processing /dev/sdb5 for mount on /tmp/snapshot/data ... [creating]..ok [mounting]..done Processing /dev/sdb6 for mount on /tmp/snapshot/data/config ... [creating]..ok [mounting]..done Processing /dev/sdb7 for mount on /tmp/snapshot/data/var ... [creating]..ok [mounting]..done Setting up swapspace version 1, size = 4 GiB (4294963200 bytes) no label, UUID=xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx Processing /dev/sdb1 for mount on /tmp/snapshot/boot ... [creating]..ok [mounting]..mkswap: /dev/sdb3: warning: wiping old swap signature. done Done with local filesystems setup. ........ Space available 14822042 K, proceeding... Copying junos-linux-install-ptx-fixed-x86-64-18.4-20180819.2... Copying /soft/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 to /tmp/snapshot//soft/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 Installing BOM... bom.xml...done bom.sh...done bom.py...done Done.

667
Copying files to /tmp/snapshot//soft/junos-linux-install-ptxfixed-x86-64-18.4-20180819.2...
Copying files for node re... Boot objects...
bzImage-re-64b.bin...done bzImage-re-64b.bin.psig...done .bzImage-re-64b.bin.hmac...done bzImage-ptx1000-rcb.dtb...done bzImage-ptx1000-rcb.dtb.psig...done FSF files... ptx-fixed-js64_Yocto_2.2_x86_64.fs...done java_Yocto_2.2_x86_64.fs...done ........ modules_Yocto_2.2_x86_64.fs...done zookeeper_Yocto_2.2_x86_64.fs...done python-2.7_Yocto_2.2_x86_64.fs...done dev_Yocto_2.2_x86_64.fs...done perl-5.22.1_Yocto_2.2_x86_64.fs...done initrd_Yocto_2.2_x86_64.fs...done initrd_Yocto_2.2_x86_64.fs.psig...done .initrd_Yocto_2.2_x86_64.fs.hmac...done python-3.5_Yocto_2.2_x86_64.fs...done jimbase_Yocto_2.2_x86_64.fs...done osbase_Yocto_2.2_x86_64.fs...done done. Done installing modules for re. Copying /data/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 Copying /data/config/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 Copying /data/etc/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 Copying /data/var_db/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 ........ Copying /data/usr_conf/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 Copying /data/var_rundb/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 Copying /data/usr_evo_share/junos-linux-install-ptx-fixedx86-64-18.4-20180819.2 Copying /data/var Copying /boot

668
Unmounting snapshot mounts Snapshot commpleted for /dev/sdb
Release Information
Command introduced before Junos OS Release 7.4. Options <config-partition> and <root-partition> introduced in Junos OS Release 13.1 for M Series, MX Series, T Series, and TX Series routers. Option media usb-port-number introduced in Junos OS Release 13.2 for MX104 routers. Options <config-partition>, <root-partition>, and <slice> deprecated for Junos OS with Upgraded FreeBSD in Junos OS Release 15.1 To determine which platforms support Junos OS with upgraded FreeBSD, see Feature Explorer and enter one of the following: · For non-virtualized, enter freebsd and select Junos kernel upgrade to FreeBSD 10+. · For virtualized, enter virtualization and select Virtualization of the Routing Engine.
RELATED DOCUMENTATION request system snapshot (Junos OS with Upgraded FreeBSD) | 668 show system snapshot | 833 show system auto-snapshot | 824
request system snapshot (Junos OS with Upgraded FreeBSD)
IN THIS SECTION Syntax | 669

669
Description | 669 Options | 670 Additional Information | 670 Required Privilege Level | 671 Output Fields | 671 Sample Output | 672 Release Information | 673
Syntax
request system snapshot <delete snapshot-name> <load snapshot-name> <media type> <recovery>
Description
Junos OS with upgraded FreeBSD has two types of snapshots: · Recovery snapshot · Non-recovery snapshot Recovery snapshots--Use the request system snapshot recovery command to create a recovery snapshot. The recovery snapshot contains copies of the packages and configuration taken at the time of the snapshot. The recovery snapshot is stored at recovery.ufs on the /oam volume. QFX with TVP platforms do not support these commands.
CAUTION: Once the platform performs a Junos OS upgrade to an upgraded FreeBSD version, (Junos OS Release 15.1R1 or higher), Junos OS will automatically generate a

670

recovery snapshot with the new Junos OS version. Thereafter, you should request a recovery snapshot every time you upgrade to a new software version.
Non-recovery snapshots--Use the request system snapshot command to create a non-recovery snapshot. The non-recovery snapshots are essentially lists of software components and configuration files, which can be helpful when major software or configuration changes are occurring and establishing a known stable system baseline is required.
On the router or switch, back up the currently running and active file system partitions to standby partitions that are not running. Non-recovery snapshots are named snap.date.time and are stored in the /packages/sets directory.
After you run the request system snapshot command, you cannot return to the previous version of the software, because the running and backup copies of the software are identical.

Options

none

On the router or switch, back up the currently running and active file system partitions to standby partitions that are not running. Specifically, this creates a nonrecovery snapshot named snap.< date>.< time> which is stored in /packages/sets.

delete

(Optional) Delete a specific non-recovery snapshot from /packages/sets. Wildcards

snapshot-name are supported, so request system snapshot delete snap* deletes all snapshots.

load snapshotname media type

(Optional) Load a specific snapshot from /packages/sets. (Optional) Specify the boot device the software is copied to:

· usb--(MX960 routers only) Copy software to the device connected to the USB port.

recovery

Create a recovery snapshot and store it in the /oam volume.

Additional Information
Before upgrading the software on the router or switch, when you have a known stable system, issue the request system snapshot command to back up the software, including the configuration, to the / packages/sets file systems. After you have upgraded the software on the router or switch and are

671
satisfied that the new packages are successfully installed and running, issue the request system snapshot command again to back up the new software to the /packages/sets file systems.
CAUTION: After you have upgraded the software on the router or switch and are satisfied that the new packages are successfully installed and running or if you have replaced one of the Routing Engines, you should also issue the request system snapshot recovery command to have a new updated recovery snapshot. Junos OS automatically recovers the Junos OS volume upon reboot, if considered defective, from the recovery snapshot, along with the configuration saved in the recovery snapshot.
The snapshot script (which is the script that generates output for non-recovery snapshots) does not generate XML output. In such cases, the <output> tag is used.
user@host> request system snapshot | display xml <rpc-reply xmlns:junos="http://xml.juniper.net/junos/18.1I0/junos"> <output> NOTICE: Snapshot snap.20180105.165049 created successfully </output> <cli> <banner></banner> </cli> </rpc-reply>
This is documented in <rpc-reply> in the Junos XML Management Protocol Developer Guide.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.

672
Sample Output
request system snapshot recovery
user@host> request system snapshot recovery Creating image ... Compressing image . . . Image size is 777MB Recovery snapshot created successfully
request system snapshot
user@host> request system snapshot NOTICE: Snapshot snap.20190412.124526 created successfully
show system snapshot
user@host> show system snapshot Non-recovery snapshots: Snapshot snap.20190412.124526: Location: /packages/sets/snap.20190412.124526 Creation date: Apr 12 12:45:26 2019 Junos version: 18.3R1.8
Total non-recovery snapshots: 1
Recovery Snapshots: Snapshots available on the OAM volume: recovery.ufs Date created: Thu Mar 28 07:44:25 PDT 2019 Junos version: 18.3R1.8
Total recovery snapshots: 1

673
request system snapshot delete
user@host> request system snapshot delete snap.20150112.122106 NOTICE: Snapshot 'snap.20150112.122106' deleted successfully
Release Information
Command introduced in Junos OS Release 15.1. Command introduced for all platforms using Junos OS with upgraded FreeBSD. To find which platforms in which releases use Junos with upgraded FreeBSD, see Feature Explorer, enter freebsd, and select Junos kernel upgrade to FreeBSD 10+.
RELATED DOCUMENTATION show system snapshot | 833
request system snapshot (Maintenance)
IN THIS SECTION Syntax | 674 Description | 674 Options | 674 Required Privilege Level | 675 Output Fields | 675 Sample Output | 676 Release Information | 677

674
Syntax
request system snapshot <config-partition> <media (compact-flash | hard-disk | internal | usb)> <partition> <root-partition> <factory> <node (all | local | node-id | primary)> <slice (alternate) >
Description
Use this command to back up the currently running and active file system partitions on the device.
Options
· config-partition-- Creates a snapshot of the configuration partition only and stores it onto the default /altconfig on the hard disk device or an /altconfig on a USB device.
· root-partition-- Creates a snapshot of the root partition only and stores it onto the default /altroot on the hard disk device or an /altroot on a USB device.
· factory-- (Optional) Specifies that only the files shipped from the factory are included in the snapshot.
· media--(Optional) Specify the boot device the software is copied to: · compact-flash--Copy software to the primary compact flash drive. · hard-disk-- Copy software to the hard disk. · usb-- Copy software to the device connected to the USB port. · internal-- Copy software to an internal flash drive. This is the default option. USB option is available on all SRX series devices; hard disk and compact-flash options are available only on SRX5800, SRX5600, and SRX5400 devices; media internal option is available only on SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices.

675
· external-- Copies software to an external storage device. This option is available for the compact flash on the SRX650 Services Gateway.
· node--(Optional) Specify the archive data and executable areas of a specific node. If you do not specify the node option, the device considers the current node as default option. · node-id--Specify for node (0, 1). · all--Specify for all nodes. · local--Specify for local nodes. · primary-- Specify for primary nodes.
· partition--(Default) Specify that the target media should be repartitioned before the backup is saved to it. The target media is partitioned whether or not it is specified in the command, because this is a mandatory option. Example: request system snapshot media usb partition Example: request system snapshot media usb partition factory
· slice--(Optional) Take a snapshot of the root partition the system has currently booted from to another slice in the same media. · alternate--(Optional) Store the snapshot on the other root partition in the system. The slice option cannot be used along with the other request system snapshot options, because the options are mutually exclusive. If you use the factory, media, or partition option, you cannot use the slice option; if you use the slice option, you cannot use any of the other options.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.

676
Sample Output
request system snapshot config-partition
user@host> request system snapshot config-partition Doing the initial labeling... Verifying compatibility of destination media partitions... Running newfs (391MB) on hard-disk media /config partition (ad1s1e)... Copying '/dev/ad0s1e' to '/dev/ad1s1e' .. (this may take a few minutes) The following filesystems were archived: /config
request system snapshot root-partition
user@host> request system snapshot root-partition Doing the initial labeling... Verifying compatibility of destination media partitions... Running newfs (3GB) on hard-disk media / partition (ad1s1a)... Copying '/dev/ad0s1a' to '/dev/ad1s1a' .. (this may take a few minutes) The following filesystems were archived: /
request system snapshot media hard-disk
user@host> request system snapshot media hard-disk Verifying compatibility of destination media partitions... Running newfs (880MB) on hard-disk media / partition (ad2s1a)... Running newfs (98MB) on hard-disk media /config partition (ad2s1e)... Copying '/dev/ad0s1a' to '/dev/ad2s1a' .. (this may take a few minutes) ...
request system snapshot media usb (when usb device is missing
user@host> request system snapshot media usb Verifying compatibility of destination media partitions... Running newfs (254MB) on usb media / partition (da1s1a)... Running newfs (47MB) on usb media /config partition (da1s1e)... Copying '/dev/da0s2a' to '/dev/da1s1a' .. (this may take a few minutes)

677
Copying '/dev/da0s2e' to '/dev/da1s1e' .. (this may take a few minutes) The following filesystems were archived: / /config
request system snapshot media compact-flash
user@host> request system snapshot media compact-flash error: cannot snapshot to current boot device
request system snapshot partition
user@host> request system snapshot partition Verifying compatibility of destination media partitions... Running newfs (439MB) on internal media / partition (da0s1a)... Running newfs (46MB) on internal media /config partition (da0s1e)... Copying '/dev/da1s1a' to '/dev/da0s1a' .. (this may take a few minutes) Copying '/dev/da1s1e' to '/dev/da0s1e' .. (this may take a few minutes) The following filesystems were archived: / /config
Release Information
Command introduced in Junos OS Release 10.2.
request system software abort in-service-upgrade (ICU)
IN THIS SECTION Syntax | 678 Description | 678 Options | 678

678
Required Privilege Level | 678 Output Fields | 679 Sample Output | 679 Release Information | 679
Syntax
request system software abort in-service-upgrade
Description
Use this command to terminate an in-band cluster upgrade (ICU). This command must be issued from a router session other than the one on which you issued the request system in-service-upgrade command that launched the ICU. If an ICU is in progress, this command terminates it. If the node is being upgraded, this command will cancel the upgrade. This command is also helpful in recovering the node in case of a failed ICU. We recommend that you use the command only when there is an issue with the ongoing session of ISSU. You may need to manually intervene to bring the system to sane state if after issuing the command the system does not recover from the terminate.
Options
This command has no options.
Required Privilege Level
view

679
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system software abort in-service-upgrade
user@host> request system software abort in-service-upgrade In-Service-Upgrade aborted
Release Information
Command introduced in Junos OS Release 15.1X49-D35.
RELATED DOCUMENTATION Upgrading Devices in a Chassis Cluster Using ICU
request system software add
IN THIS SECTION Syntax | 680 Syntax (EX Series Switches) | 681 Syntax (TX Matrix Router) | 681 Syntax (TX Matrix Plus Router) | 682 Syntax (MX Series Router) | 682 Syntax (QFX Series) | 683

680
Syntax (OCX Series) | 683 Syntax (Junos OS Evolved) | 684 Description | 684 Options | 685 Additional Information | 689 Required Privilege Level | 690 Output Fields | 691 Sample Output | 691 Release Information | 704
Syntax
request system software add package-name <best-effort-load> <delay-restart> <device-alias alias-name> <force> <no-copy> <no-validate> <re0 | re1> <reboot> <satellite slot-id> <set [package-name1 package-name2]> <unlink> <upgrade-group [all |upgrade-group-name]> <upgrade-with-config> <satellite slot-id> <validate> <version version-string>

681
Syntax (EX Series Switches)
request system software add package-name <best-effort-load> <delay-restart> <force> <no-copy> <no-validate> <re0 | re1> <reboot> <set [package-name1 package-name2]> <upgrade-with-config> <validate> <validate-on-host hostname> <validate-on-routing-engine routing-engine>
Syntax (TX Matrix Router)
request system software add package-name <best-effort-load> <delay-restart> <force> <lcc number | scc> <no-copy> <no-validate> <re0 | re1> <reboot> <set [package-name1 package-name2]> <unlink> <upgrade-with-config> <validate> <validate-on-host hostname> <validate-on-routing-engine routing-engine>

682
Syntax (TX Matrix Plus Router)
request system software add package-name <best-effort-load> <delay-restart> <force> <lcc number | sfc number> <no-copy> <no-validate> <re0 | re1> <reboot> <set [package-name1 package-name2]> <unlink> <upgrade-with-config> <validate> <validate-on-host hostname> <validate-on-routing-engine routing-engine>
Syntax (MX Series Router)
request system software add package-name <best-effort-load> <delay-restart> <device-alias alias-name> <force> <member member-id> <no-copy> <no-validate> <re0 | re1> <reboot> <satellite slot-id> <set [package-name1 package-name2]> <upgrade-group [all |upgrade-group-name]> <unlink> <upgrade-with-config> <validate> <version version-string>

683
<validate-on-host hostname> <validate-on-routing-engine routing-engine>
Syntax (QFX Series)
request system software add package-name <best-effort-load> <component all> <delay-restart> <force> <force-host> <no-copy> <partition> <reboot> <unlink> <upgrade-with-config>
Syntax (OCX Series)
request system software add package-name <best-effort-load> <delay-restart> <force> <force-host> <no-copy> <no-validate> <reboot> <unlink> <upgrade-with-config> <validate>

684
Syntax (Junos OS Evolved)
request system software add package-name <force> <no-validate> <reboot> <restart>
Description
For Junos OS Evolved, the request system software add command has a built-in feature not to start the upgrade if a reboot is pending after an upgrade or rollback.
We recommend that you always download the software image to /var/tmp only. On EX Series and QFX Series switches, you must use the /var/tmp directory. Other directories are not supported.
Install a software package or bundle on the router or switch.
For information on valid filename and URL formats, see Format for Specifying Filenames and URLs in Junos OS CLI Commands.
Any configuration changes performed after inputting the request system software add command will be lost when the system reboots with an upgraded version of Junos OS.
Starting from Junos OS Release 17.2R1, PTX10008 routers do not support the request system software add command. Starting from Junos OS Release 17.4R1, PTX10016 routers do not support the request system software add command. Use the request vmhost software add command instead of the request system software add command on the PTX10008 and PTX10016 routers to install or upgrade the Junos OS software package or bundle on the router. See request vmhost software add.
When graceful Routing Engine switchover (GRES) is enabled on a device, you must perform a unified inservice software upgrade (ISSU) operation to update the software running on the device. With GRES enabled, if you attempt to perform a software upgrade by entering the request system software add package-name command, an error message is displayed stating that only in-service software upgrades are supported when GRES is configured. In such a case, you must either remove the GRES configuration before you attempt the upgrade or perform a unified ISSU.
Starting with Junos OS Release 15.1F3, the statement request system software add installs a software package for the guest OS only for the PTX5000 router with RE-DUO-C2600-16G, and for MX240, MX480, and MX960 routers with RE-S-1800X4-32G-S.

685
Starting with Junos OS Release 15.1F5, the statement request system software add installs a software package for the guest OS only for the MX2010 and MX2020 routers with REMX2K-1800-32G-S. On these routers, in order to install both Junos software and host software packages, use the request vmhost software add command.

Options
package-name

Location from which the software package or bundle is to be installed.
In Junos OS, package-name can be either the URL of a remote location or the pathname of a local package. But Junos OS Evolved does not support a remote iso for upgrade, so "URL" is removed from the help string in the CLI.
For example:
· /var/tmp/package-name--For a software package or bundle that is being installed from a local directory on the router or switch.
· protocol://hostname/pathname/package-name--For a software package or bundle that is to be downloaded and installed from a remote location. Replace protocol with one of the following:
· ftp--File Transfer Protocol.
Use ftp://hostname/pathname/package-name. To specify authentication credentials, use ftp://<username>:<password>@hostname/pathname/ package-name. To have the system prompt you for the password, specify prompt in place of the password. If a password is required, and you do not specify the password or prompt, an error message is displayed.
· http--Hypertext Transfer Protocol.
Use http://hostname/pathname/package-name. To specify authentication credentials, use http://<username>:<password>@hostname/pathname/ package-name. If a password is required and you omit it, you are prompted for it.
· scp--Secure copy (not available for limited editions).

686

Use scp://hostname/pathname/package-name. To specify authentication credentials, use scp://<username>:<password>@hostname/pathname/ package-name.
· The pathname in the protocol is the relative path to the user's home directory on the remote system and not the root directory.
· Do not use the scp protocol in the request system software add command to download and install a software package or bundle from a remote location. The previous statement does not apply to the QFabric switch. The software upgrade is handled by the management process (mgd), which does not support scp.

Use the file copy command to copy the software package or bundle from the remote location to the /var/tmp directory on the hard disk:

file copy scp://source/package-name /var/tmp

Then install the software package or bundle using the request system software add command:

request system software add /var/tmp/package-name

best-effort-load

(Optional) Activate a partial load and treat parsing errors as warnings instead of errors.

component all

(QFabric systems only) (Optional) Install the software package on all of the QFabric components.

delay-restart

(Optional) Install a software package or bundle, but do not restart software processes.

device-alias aliasname

(Junos Fusion only) (Optional) Install the satellite software package onto the specified satellite device using the satellite device's alias name.

force

(Optional) Force the addition of the software package or bundle (ignore warnings).
For Junos OS Evolved, if you are trying to reinstall an already installed application, use the force option. The force option will cause the program to remove the existing application before reinstalling it.

force-host

(Optional) Force the addition of the host software package or bundle (ignore warnings) on the QFX5100 device.

687

lcc number

(TX Matrix routers and TX Matrix Plus routers only) (Optional) In a routing matrix based on the TX Matrix router, install a software package or bundle on a T640 router that is connected to the TX Matrix router. In a routing matrix based on the TX Matrix Plus router, install a software package or bundle on a router that is connected to the TX Matrix Plus router.
Replace number with the following values depending on the LCC configuration:

· 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

· 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

· 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

· 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

member member- (MX Series routers only) (Optional) Install a software package on the specified

id

Virtual Chassis member. Replace member-id with a value of 0 or 1.

partition

(QFX3500 switches only) (Optional) Format and repartition the media before installation.

satellite slot-id

(Junos Fusion only) (Optional) Install the satellite software package onto the specified satellite device using the satellite devices FPC slot identifier.

scc

(TX Matrix routers only) (Optional) Install a software package or bundle on a

Routing Engine on a TX Matrix router (or switch-card chassis).

sfc number

(TX Matrix Plus routers only) (Optional) Install a software package or bundle on a Routing Engine on a TX Matrix Plus router. Replace number with 0.

no-copy

(Optional) Install a software package or bundle, but do not save copies of the package or bundle files.

no-validate

(Optional) When loading a software package or bundle with a different release, suppress the default behavior of the validate option.

Software packages from unidentified providers cannot be loaded. To authorize providers, include the provider-id statement at the [edit system extensions provider] hierarchy level.

688

re0 | re1 reboot restart set [packagename1packagename2]
unlink

(Optional) On routers or switches that support dual or redundant Routing Engines, load a software package or bundle on the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).
(Optional) After adding the software package or bundle, reboot the system. On a QFabric switch, the software installation is not complete until you reboot the component for which you have installed the software.
The reboot command is not needed to install third-party applications on devices running Junos OS Evolved.
(Optional) (For Junos OS Evolved only) This option allows you to upgrade the system using an application-level restart without requiring a reboot when possible. First the system determines how many applications need to restart (start with a new version), and then, after sending output to the CLI session, it restarts those applications. Restarted applications resync their state from the system. You can use the request system software validate-restart command before using the request system software add restart command to determine if the upgrade to the new image can be done by application-restart or if it requires a reboot.
(Mixed EX4200 and EX4500 Virtual Chassis, M Series, MX Series, and T Series routers only) (Optional) Install multiple packages at same time:
· In the case of mixed EX4200 and EX4500 Virtual Chassis, install two software packages--a package for an EX4200 switch and the same release of the package for an EX4500 switch--to upgrade all member switches in a mixed EX4200 and EX4500 Virtual Chassis.
· In the case of M Series, MX Series, and T Series routers, install multiple (two or more) software packages and software add-on packages at the same time. The variable package-name can either be a list of installation packages, each separated by a blank space, or the full URL to the directory or tar file containing the list of installation packages.
In each case, installation-package can either be a list of installation packages, each separated by a blank space, or the full URL to the directory or tar file containing the list of installation packages.
Use the request system software add set command to retain any SDK configuration by installing the SDK add-on packages along with the core Junos OS installation package.
(Optional) On M Series, T Series, and MX Series routers, use the unlink option to remove the software package from this directory after a successful upgrade is completed.

689

upgrade-group [ all |upgrade-groupname]

(Junos Fusion only) (Required to configure a Junos Fusion using autoconversion or manual conversion) Associate a satellite software image with a satellite software upgrade group. The satellite software package is associated with the specified satellite software upgrade group using the upgrade-group-name, or for all satellite software upgrade groups in a Junos Fusion when the all keyword is specified.

A satellite software upgrade group is a group of satellite devices in a Junos Fusion that are designated to upgrade to the same satellite software version using the same satellite software package. See Understanding Software in a Junos Fusion Provider Edge, Understanding Software in a Junos Fusion Enterprise, and Managing Satellite Software Upgrade Groups in a Junos Fusion.

upgrade-withconfig

(Optional) Install one or more configuration files.
Configuration files specified with this option must have the extension .text or .xml and have the extension specified. Using the extension .txt will not work.

validate

(Optional) Validate the software package or bundle against the current configuration as a prerequisite to adding the software package or bundle. This is the default behavior when the software package or bundle being added is a different release.

The validate option only works on systems that do not have graceful-switchover (GRES) enabled. To use the validate option on a system with GRES, either disable GRES for the duration of the installation, or install using the command request system software in-service-upgrade, which requires nonstop active routing (NSR) to be enabled when using GRES.

validate-on-host hostname

(Optional) Validate the software package by comparing it to the running configuration on a remote Junos OS host. Specify a host, replacing hostname with the remote hostname. You can optionally provide the username that will be used to log in to the remote host by specifying the hostname in the format user@hostname.

validate-onrouting-engine routing-engine

(Optional) Validate the software bundle or package by comparing it to the running configuration on a Junos OS Routing Engine on the same chassis. Specify a Routing Engine, replacing routing-engine with the routing engine name.

Additional Information
Before upgrading the software on the router or switch, when you have a known stable system, issue the request system snapshot command to back up the software, including the configuration, to the /altroot

690
and /altconfig file systems. After you have upgraded the software on the router or switch and are satisfied that the new package or bundle is successfully installed and running, issue the request system snapshot command again to back up the new software to the /altroot and /altconfig file systems.
The request system snapshot command is currently not supported on the QFabric system. Also, you cannot add or install multiple packages on a QFabric system.
After you run the request system snapshot command, you cannot return to the previous version of the software because the running and backup copies of the software are identical.
If you are upgrading more than one package at the same time, delete the operating system package, jkernel, last. Add the operating system package, jkernel, first and the routing software package, jroute, last. If you are upgrading all packages at once, delete and add them in the following order:
user@host> request system software add /var/tmp/jbase user@host> request system software add /var/tmp/jkernel user@host> request system software add /var/tmp/jpfe user@host> request system software add /var/tmp/jdocs user@host> request system software add /var/tmp/jroute user@host> request system software add /var/tmp/jcrypto
By default, when you issue the request system software add package-name command on a TX Matrix primary Routing Engine, all the T640 primary Routing Engines that are connected to it are upgraded to the same version of software. If you issue the same command on the TX Matrix backup Routing Engine, all the T640 backup Routing Engines that are connected to it are upgraded to the same version of software.
Likewise, when you issue the request system software add package-name command on a TX Matrix Plus primary Routing Engine, all the T1600 or T4000 primary Routing Engines that are connected to it are upgraded to the same version of software. If you issue the same command on the TX Matrix Plus backup Routing Engine, all the T1600 or T4000 backup Routing Engines that are connected to it are upgraded to the same version of software.
Before installing software on a device that has one or more custom YANG data models added to it, back up and remove the configuration data corresponding to the custom YANG data models from the active configuration. For more information see Managing YANG Packages and Configurations During a Software Upgrade or Downgrade.
Required Privilege Level
maintenance

691
Output Fields
When you enter this command, you are provided feedback on the status of your request.

Sample Output
request system software add validate

user@host> request system software add validate /var/tmp/ jinstall-7.2R1.7-domestic-signed.tgz Checking compatibility with configuration Initializing... Using jbase-7.1R2.2 Using /var/tmp/jinstall-7.2R1.7-domestic-signed.tgz Verified jinstall-7.2R1.7-domestic.tgz signed by PackageProduction_7_2_0 Using /var/validate/tmp/jinstall-signed/jinstall-7.2R1.7-domestic.tgz Using /var/validate/tmp/jinstall/jbundle-7.2R1.7-domestic.tgz Checking jbundle requirements on / Using /var/validate/tmp/jbundle/jbase-7.2R1.7.tgz Using /var/validate/tmp/jbundle/jkernel-7.2R1.7.tgz Using /var/validate/tmp/jbundle/jcrypto-7.2R1.7.tgz Using /var/validate/tmp/jbundle/jpfe-7.2R1.7.tgz Using /var/validate/tmp/jbundle/jdocs-7.2R1.7.tgz Using /var/validate/tmp/jbundle/jroute-7.2R1.7.tgz Validating against /config/juniper.conf.gz mgd: commit complete Validation succeeded Validating against /config/rescue.conf.gz mgd: commit complete Validation succeeded Installing package '/var/tmp/jinstall-7.2R1.7-domestic-signed.tgz' ... Verified jinstall-7.2R1.7-domestic.tgz signed by PackageProduction_7_2_0 Adding jinstall...

WARNING: WARNING: WARNING: WARNING: WARNING: WARNING:

This package will load JUNOS 7.2R1.7 software. It will save JUNOS configuration files, and SSH keys (if configured), but erase all other files and information stored on this machine. It will attempt to preserve dumps and log files, but this can not be guaranteed. This is the pre-installation stage and all the software is loaded when

692

WARNING:

you reboot the system.

Saving the config files ... Installing the bootstrap installer ...

WARNING: WARNING: WARNING: WARNING: WARNING:

A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the 'request system reboot' command when software installation is complete. To abort the installation, do not reboot your system, instead use the 'request system software delete jinstall' command as soon as this operation completes.

Saving package file in /var/sw/pkg/jinstall-7.2R1.7-domestic-signed.tgz ... Saving state for rollback ...

request system software add /var/tmp/ no-validate
user@host> request system software add no-validate /var/tmp/junos-install-mx-x86-32-15.1R1.9.tgz Installing package '/var/tmp/junos-install-mx-x86-32-15.1R1.9.tgz' ... Verified manifest signed by PackageProductionEc_2015 Verified manifest signed by PackageProductionRSA_2015 Verified contents.iso Verified issu-indb.tgz Verified junos-x86-32.tgz Verified kernel Verified metatags Verified package.xml Verified pkgtools.tgz camcontrol: not found camcontrol: not found Verified manifest signed by PackageProductionEc_2015 Saving the config files ... NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.preinstall Saving package file in /var/sw/pkg/junos-install-x86-32domestic-20150618.043753_builder_junos_151_r1.tgz ... Saving state for rollback ...

693
request system software add no-copy no-validate reboot
user@host> request system software add no-copy no-validate junos-install-srx-x86-64-17.3R1.tgz reboot Verified junos-install-srx-x86-64-17.3R1 signed by PackageProductionEc_2017 method ECDSA256+SHA256 Verified manifest signed by PackageProductionEc_2017 method ECDSA256+SHA256 Checking PIC combinations Verified fips-mode signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding fips-mode-x86-32-20170728.153050_builder_junos_173_r1 ... Verified jail-runtime signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding jail-runtime-x86-32-20170725.352915_builder_stable_10 ... Verified jdocs signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding jdocs-x86-32-20170728.153050_builder_junos_173_r1 ... Verified jfirmware signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding jfirmware-x86-32-17.3R1 ... Verified jpfe-X signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding jpfe-X-x86-32-20170728.153050_builder_junos_173_r1 ... Verified jpfe-X960 signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding jpfe-X960-x86-32-20170728.153050_builder_junos_173_r1 ... Verified jpfe-common signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding jpfe-common-x86-32-20170728.153050_builder_junos_173_r1 ... Verified jpfe-fips signed by PackageProductionEc_2017 method ECDSA256+SHA256 Verified jpfe-wrlinux signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding jpfe-wrlinux-x86-32-20170728.153050_builder_junos_173_r1 ... Verified jsd-jet-1 signed by PackageProductionEc_2017 method ECDSA256+SHA256 Adding jsd-x86-32-17.3R1-jet-1 ...
request system software add validate-on-host
user@host> request system software add validate-on-host user@xyz :/var/tmp/ jinstall-15.1-20150516_ib_15_2_psd.0-domestic-signed.tgz user@host> request system software add validate-on-host user@xyz :/var/tmp/ jinstall-15.1-20150516_ib_15_2_psd.0-domestic-signed.tgz Extracting JUNOS version from package... Connecting to remote host xyz... Password: Sending configuration to xyz... Validating configuration on xyz... PACKAGETYPE: not found Checking compatibility with configuration

694

Initializing... Using jbase-15.1-20150516_ib_15_2_psd.0 Verified manifest signed by PackageDevelopmentEc_2015 Using jruntime-15.1-20150516_ib_15_2_psd.0 Verified manifest signed by PackageDevelopmentEc_2015 Using jkernel-15.1-20150516_ib_15_2_psd.0 Verified manifest signed by PackageDevelopmentEc_2015 Using jroute-15.1-20150516_ib_15_2_psd.0 Verified manifest signed by PackageDevelopmentEc_2015 Using jcrypto-15.1-20150516_ib_15_2_psd.0 Verified manifest signed by PackageDevelopmentEc_2015 Using jweb-15.1-20150516_ib_15_2_psd.0 Verified manifest signed by PackageDevelopmentEc_2015 Using /var/packages/jtools-15.1-20150516_ib_15_2_psd.0 Verified manifest signed by PackageDevelopmentEc_2015 Using /var/tmp/config.tgz Hardware Database regeneration succeeded Validating against /config/juniper.conf.gz mgd: warning: schema: init: 'logical-systems-vlans' contains-node 'juniperconfig vlans': not found mgd: commit complete Validation succeeded Installing package '/var/tmp/jinstall-15.1-20150516_ib_15_2_psd.0-domesticsigned.tgz' ... Verified jinstall-15.1-20150516_ib_15_2_psd.0-domestic.tgz signed by PackageDevelopmentEc_2015 Adding jinstall...

WARNING: WARNING:

The software that is being installed has limited support. Run 'file show /etc/notices/unsupported.txt' for details.

WARNING: WARNING: WARNING: WARNING: WARNING: WARNING: WARNING:

This package will load JUNOS 15.1-20150516_ib_15_2_psd.0 software. It will save JUNOS configuration files, and SSH keys (if configured), but erase all other files and information stored on this machine. It will attempt to preserve dumps and log files, but this can not be guaranteed. This is the pre-installation stage and all the software is loaded when you reboot the system.

Saving the config files ... NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.preinstall

695

Installing the bootstrap installer ...

WARNING: WARNING: WARNING: WARNING: WARNING:

A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the 'request system reboot' command when software installation is complete. To abort the installation, do not reboot your system, instead use the 'request system software delete jinstall' command as soon as this operation completes.

Saving package file in /var/sw/pkg/jinstall-15.1-20150516_ib_15_2_psd.0-domesticsigned.tgz ... Saving state for rollback ...

request system software add (Mixed EX4200 and EX4500 Virtual Chassis)
user@switch> request system software add set [/var/tmp/jinstall-ex-4200-11.1R1.1-domesticsigned.tgz /var/tmp/jinstall-ex-4500-11.1R1.1-domestic-signed.tgz] ...

request system software add component all (QFabric Systems)
user@switch> request system software add /pbdata/packages/jinstall-qfabric-12.2X50-D1.3.rpm component all ...

request system software add upgrade-group (Junos Fusion)
user@aggregation-device> request system software add /var/tmp/satellite-3.0R1.1-signed.tgz upgrade-group group1

request system software add restart (Junos OS Evolved for fixed form platforms)
user@device> request system software add restart /var/tmp/qfx-ms-fixed-1-target1-ifmanarpcos.iso Adding software images. This process can take several minutes. Please be patient... Download and Validate in Progress re0: Starting upgrade : /var/tmp/qfx-ms-fixed-1-target1-ifmanarpcos.iso

696
re0: Single RE upgrade detected. re0: Installing IMA keys of the incoming ISO image... re0: Validating existing configs. See /var/log/validation_config.log for config validation logs. re0: Validation Passed. Going ahead with Installation re0: Starting the installation... re0: Copying files to //soft/junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190523235333-1... re0: Running post install commands... re0: Post install sequence was successful. re0: Installation of image junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190523235333-1 done. re0: Boot version is now 'junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190523235333-1' Image validation and installation succeeded. Restarting Applications.
*** Restart Apps list *** arpd ifmand cosd Activating active instance of app arpd on node re0 Activating active instance of app ifmand on node re0 Activating active instance of app cosd on node re0 Image activation succeeded for arpd on node re0 Stopping active instance of app arpd on node re0 Image activation succeeded for ifmand on node re0 Stopping active instance of app ifmand on node re0 Image activation succeeded for cosd on node re0 Stopping active instance of app cosd on node re0 App arpd stopped on node re0 Starting active instance of app arpd on node re0 App ifmand stopped on node re0 Starting active instance of app ifmand on node re0 App cosd stopped on node re0 Starting active instance of app cosd on node re0 App cosd started/restarted on node re0 App ifmand started/restarted on node re0 App arpd started/restarted on node re0 *** Restart Summary ***
*** Restart Success *** arpd ifmand

697
cosd Please check the status of applications using 'show system alarms'
command-name
user@device> request system software add restart /var/tmp/qfx-ms-fixed-1-target2ifmanarpcossysman.iso Adding software images. This process can take several minutes. Please be patient... Download and Validate in Progress re0: Starting upgrade : /var/tmp/qfx-ms-fixed-1-target2-ifmanarpcossysman.iso re0: Single RE upgrade detected. re0: Installing IMA keys of the incoming ISO image... re0: Validating existing configs. See /var/log/validation_config.log for config validation logs. re0: Validation Passed. Going ahead with Installation re0: Starting the installation... re0: Copying files to //soft/junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190523235731-1... re0: Running post install commands... re0: Post install sequence was successful. re0: Installation of image junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190523235731-1 done. re0: Boot version is now 'junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190523235731-1' Image validation and installation succeeded. Restarting Applications.
*** Restart Apps list *** sysman arpd ifmand cosd Activating active instance of app sysman on node re0 Image activation succeeded for sysman on node re0 Restarting active instance of app sysman on node re0 App sysman started/restarted on node re0 Activating active instance of app arpd on node re0 Activating active instance of app ifmand on node re0 Activating active instance of app cosd on node re0 Image activation succeeded for arpd on node re0 Stopping active instance of app arpd on node re0

698
Image activation succeeded for ifmand on node re0 Stopping active instance of app ifmand on node re0 Image activation succeeded for cosd on node re0 Stopping active instance of app cosd on node re0 App cosd stopped on node re0 Starting active instance of app cosd on node re0 App ifmand stopped on node re0 Starting active instance of app ifmand on node re0 App arpd stopped on node re0 Starting active instance of app arpd on node re0 App cosd started/restarted on node re0 App ifmand started/restarted on node re0 App arpd started/restarted on node re0 *** Restart Summary ***
*** Restart Success *** sysman arpd ifmand cosd Please check the status of applications using 'show system alarms'
command-name
user@device> request system software add restart /var/tmp/qfx-ms-fixed-1-target3ifmanarpcossysmanimgdorchd.iso ifmanarpcossysmanimgdor Adding software images. This process can take several minutes. Please be patient... Download and Validate in Progress re0: Starting upgrade : /var/tmp/qfx-ms-fixed-1-target3ifmanarpcossysmanimgdorchd.iso re0: Single RE upgrade detected. re0: Installing IMA keys of the incoming ISO image... re0: Validating existing configs. See /var/log/validation_config.log for config validation logs. re0: Validation Passed. Going ahead with Installation re0: Starting the installation... re0: Copying files to //soft/junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190524000025... re0: Running post install commands... re0: Post install sequence was successful.

699
re0: Installation of image junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190524000025-gsanka-1 done. re0: Boot version is now 'junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190524000025' Image validation and installation succeeded. Restarting Applications.
*** Restart Apps list *** sysman arpd ifmand cosd imgd orchestratord Activating active instance of app sysman on node re0 Image activation succeeded for sysman on node re0 Restarting active instance of app sysman on node re0 App sysman started/restarted on node re0 Activating active instance of app arpd on node re0 Activating active instance of app ifmand on node re0 Activating active instance of app cosd on node re0 Image activation succeeded for arpd on node re0 Stopping active instance of app arpd on node re0 Image activation succeeded for ifmand on node re0 Stopping active instance of app ifmand on node re0 Image activation succeeded for cosd on node re0 Stopping active instance of app cosd on node re0 App arpd stopped on node re0 Starting active instance of app arpd on node re0 App ifmand stopped on node re0 Starting active instance of app ifmand on node re0 App cosd stopped on node re0 Starting active instance of app cosd on node re0 App cosd started/restarted on node re0 App arpd started/restarted on node re0 App ifmand started/restarted on node re0 Activating active instance of app imgd on node re0 Activating active instance of app orchestratord on node re0 Image activation succeeded for imgd on node re0 Image activation succeeded for orchestratord on node re0 Restarting active instance of app imgd on node re0 Restarting active instance of app orchestratord on node re0

700
request system software add restart (Junos OS Evolved for chassis-based platforms)
user@host> request system software add a.iso restart Adding software images. This process can take several minutes. Please be patient...
*** List of Offlined FPCs *** FPC0 FPC1 FPC2
Perform online for above FPCs (y/n) ? y
*** Incompatible FPCs ***
FPC0 FPC1
Warning: Perform offline for above incompatible FPCs
Perform offline for above incompatible FPCs (y/n) ? n
Aborting Software Upgrade
user@host>
command-name
user@host> request system software add a.iso restart Adding software images. This process can take several minutes. Please be patient...  *** Unsupported frus list *** fpc0  Perform offline for above unsupported FPCs  Offline the incompatible FRUs before proceeding for upgrade? Enter yes to proceed with offline for incompatible frus or no to abort the

701
upgrade.. Proceed? [yes,no] (no) yes   *** Restart Apps list *** sysman arpd mgd orchestratord  *** Offlining of Unsupported frus may take few mins *** fpc0 has been successfully offlined  *** Offlining of Unsupported frus are done *** Activating active instance of app sysman on node re0 Activating active instance of app sysman on node re1 Activating active instance of app sysman on node fpc0 Image activation succeeded for sysman on node re0 Restarting active instance of app sysman on node re0 Image activation succeeded for sysman on node re1 Restarting active instance of app sysman on node re1 Image activation failed on node fpc0 App does not exist sysman on node fpc0 App sysman started/restarted on node re0 App sysman started/restarted on node re1 Activating active instance of app arpd on node re0 Image activation succeeded for arpd on node re0 Stopping active instance of app arpd on node re0 App arpd stopped on node re0 Starting active instance of app arpd on node re0 App arpd started/restarted on node re0 Activating active instance of app mgd on node re0 Activating active instance of app mgd on node re1 Activating active instance of app orchestratord on node re0 Image activation succeeded for mgd on node re0 Image activation succeeded for mgd on node re1 Image activation succeeded for orchestratord on node re0 Activating new version of the software on node fpc0 Activating new version of the software on node re0 Activating new version of the software on node re1 Image activation failed on node fpc0 Image activation succeeded on node re0 Image activation succeeded on node re1 

702
*** Onlining of Unsupported frus may take few mins *** fpc0 could not to be onlined  *** Onlining of Unsupported frus are done *** Restarting active instance of app mgd on node re0 Restarting active instance of app mgd on node re1 Restarting active instance of app orchestratord on node re0 *** Restart Summary ***  *** Restart Success ***  sysman  sysman  arpd  *** Restart Failure ***  sysman Please restart the failed applications Please check the status of applications using 'show system alarms'  WARNING: cli has been replaced by an updated version: CLI release 20190916.173330_rbu-builder.r1055817 built by rbu-builder on 2019-09-16 18:02:02 UTC Restart cli using the new version ? [yes,no] (yes) yes  Restarting cli ... {master} user@host>
request system software add no-validate (SRX Series device)
user@host> request system software add /var/tmp/junossrxsme-20.4I-20200810_dev_common.0.0833.tgz no-copy no-validate Formatting alternate root (/dev/ad0s2a)... /dev/ad0s2a: 600.0MB (1228732 sectors) block size 16384, fragment size 2048
using 4 cylinder groups of 150.00MB, 9600 blks, 19200 inodes. super-block backups (for fsck -b #) at: 32, 307232, 614432, 921632 Installing package '/altroot/cf/packages/install-tmp/ junos-20.4I-20200810_dev_common.0.0833' ... Verified junos-boot-srxsme.tgz signed by PackageDevelopmentECP256_2020 method ECDSA256+SHA256 Verified junos-srxsme-domestic signed by PackageDevelopmentECP256_2020 method ECDSA256+SHA256

703

Verified manifest signed by PackageDevelopmentECP256_2020 method ECDSA256+SHA256

WARNING: WARNING:

The software that is being installed has limited support. Run 'file show /etc/notices/unsupported.txt' for details.

JUNOS 20.4I-20200810_dev_common.0.0833 will become active at next reboot

WARNING: A reboot is required to load this software correctly

WARNING:

Use the 'request system reboot' command

WARNING:

when software installation is complete

Saving state for rollback ...

user@host> request system software add /var/tmp/junos-srxsme-19.4R1.3.tgz no-copy no-validate WARNING: Package junos-19.4R1.3 version 19.4R1.3 is not compatible with current loader WARNING: Automatic recovering loader, please wait ... Upgrading Loader... ##################################### Verifying the loader image... OK WARNING: The new boot firmware will take effect when the system is rebooted. WARNING: Loader recover finish. Formatting alternate root (/dev/ad0s1a)... /dev/ad0s1a: 598.5MB (1225692 sectors) block size 16384, fragment size 2048
using 4 cylinder groups of 149.62MB, 9576 blks, 19200 inodes. super-block backups (for fsck -b #) at: 32, 306464, 612896, 919328 Installing package '/altroot/cf/packages/install-tmp/junos-19.4R1.3' ... Verified junos-boot-srxsme-19.4R1.3.tgz signed by PackageProductionEc_2019 method ECDSA256+SHA256 Verified junos-srxsme-19.4R1.3-domestic signed by PackageProductionEc_2019 method ECDSA256+SHA256 Verified junos-boot-srxsme-19.4R1.3.tgz signed by PackageProductionEc_2019 method ECDSA256+SHA256 V erified junos-srxsme-19.4R1.3-domestic signed by PackageProductionEc_2019 method ECDSA256+SHA256 JUNOS 19.4R1.3 will become active at next reboot WARNING: A reboot is required to load this software correctly WARNING: Use the 'request system reboot' command WARNING: when software installation is complete Saving state for rollback ...

704
request system software add (SRX Series device)
user@host> request system software add /var/tmp/junos-srxsme-19.4R2.3.tgz WARNING: Package junos-19.4R2.3 version 19.4R2.3 is not compatible with this system. WARNING: Please install a package with veloadr support, 20.3 or higher.
Release Information
Command introduced before Junos OS Release 7.4. best-effort-load and unlink options added in Junos OS Release 7.4. sfc option introduced in Junos OS Release 9.6 for the TX Matrix Plus router. set [package-name1package-name2] option added in Junos OS Release 11.1 for EX Series switches. Added in Junos OS Release 12.2 for M Series, MX Series, and T Series routers. On EX Series switches, the set [package-name1package-name2] option allows you to install only two software packages on a mixed EX4200 and EX4500 Virtual Chassis. Whereas, on M Series, MX Series, and T Series routers, the set [package-name1package-name2package-name3] option allows you to install multiple software packages and software add-on packages at the same time. upgrade-with-config and upgrade-with-config-format format options added in Junos OS Release 12.3 for M Series routers, MX Series routers, and T Series routers, EX Series Ethernet switches, and QFX Series devices. device-alias, satellite, upgrade-group, and version options introduced in Junos OS Release 14.2R3 for Junos Fusion. validate-on-host and validate-on-routing-engine options added in Junos OS Release 15.1F3 for PTX5000 routers and MX240, MX480, and MX960 routers. upgrade-with-config-format format option deleted in Junos OS Release 16.1 for M Series routers, MX Series routers, and T Series routers, EX Series Ethernet switches, and QFX Series devices. The following options are deprecated in Junos OS Evolved Release 18.3R1: best-effort-load, delayrestart, no-copy, on-primary, (re0 | re1), set, unlink, validate, validate-on-host, and validate-on-routingengine.

705
RELATED DOCUMENTATION Format for Specifying Filenames and URLs in Junos OS CLI Commands request system software delete | 711 request system software rollback | 726 request system storage cleanup | 754 Installing Software Packages on QFX Series Devices Upgrading Software on a QFabric System Managing Satellite Software Upgrade Groups in a Junos Fusion request system software add (Maintenance) Routing Matrix with a TX Matrix Plus Router Solutions Page
request system software add (Maintenance)
IN THIS SECTION Syntax | 705 Description | 706 Options | 706 Required Privilege Level | 706 Release Information | 706
Syntax
request system software add package-name

706
Description
Use this command to install new software package on the device, for example: request system software add junos-srxsme-10.0R2-domestic.tgz no-copy no-validate partition reboot.
Options
· delay­restart--Install the software package but does not restart the software process. · best-effort-load--Activate a partial load and treat parsing errors as warnings instead of errors. · no-copy--Install the software package but does not saves the copies of package files. · no-validate--Do not check the compatibility with current configuration before installation starts. · partition--Format and re-partition the media before installation. · reboot--Reboot the device after installation is completed. · unlink--Remove the software package after successful installation. · validate--Check the compatibility with current configuration before installation starts.
Required Privilege Level
maintenance
Release Information
Partition option introduced in the command in Junos OS Release 10.1.

707
request system software configuration-backup
IN THIS SECTION Syntax | 707 Description | 707 Options | 707 Required Privilege Level | 708 Output Fields | 708 Sample Output | 708 Release Information | 708
Syntax
request system software configuration-backup (path)
Description
Use this command to save the currently active configuration and any installation-specific parameters such as a configuration that you have entered outside of the CLI, director group IP addresses, and the default partition IP address.
Options
path--(QFabric System) Provide the path to the location of the backup configuration files. You can save the backup configuration files to either a URL, local directory, remote server, or removable drive.

708
Required Privilege Level
configure--To enter configuration mode, but other required privilege levels depend on where the statement is located in the configuration hierarchy.

Output Fields
When you enter this command, you are provided feedback on the status of your request.

Sample Output
request system software configuration-backup

user@switch request system software configuration-backup ftp://ftp.test.net/test

% Total % Received % Xferd Average Speed Time Time

Time Current

Dload Upload Total Spent Left

Speed

100

4035

0 0 100 4035 0

138k --:--:-- --:--:--

--:--:-- 0

Release Information
Command introduced in Junos OS Release 11.3.
RELATED DOCUMENTATION request system software configuration-restore | 709

709
request system software configuration-restore
IN THIS SECTION Syntax | 709 Description | 709 Options | 709 Required Privilege Level | 710 Output Fields | 710 Sample Output | 710 Release Information | 710
Syntax
request system software configuration-restore (path)
Description
Use this command to restore a previously saved configuration and any installation-specific parameters, such as a configuration that you have entered outside of the CLI, director group IP addresses, and the default partition IP address.
Options
path--(QFabric System) Provide the path to the location of the backup configuration files. The path can be to a local file, a file on an external flash drive, or an SCP or FTP destination.

710
Required Privilege Level
configure--To enter configuration mode, but other required privilege levels depend on where the statement is located in the configuration hierarchy.

Output Fields
When you enter this command, you are provided feedback on the status of your request.

Sample Output
request system software configuration-restore

user@switch request system software configuration-restore ftp://ftp.test.net/test

% Total % Received % Xferd Average Speed Time Time

Time Current

Dload Upload Total Spent Left Speed

100 4035 100 4035 0

0 153k

0 --:--:-- --:--:-- --:--:-- 3803k

Release Information
Command introduced in Junos OS Release 11.3.
RELATED DOCUMENTATION request system software configuration-backup | 707 Performing a QFabric System Recovery Installation on the Director Group

711
request system software delete
IN THIS SECTION Syntax | 711 Syntax (TX Matrix Router) | 711 Syntax (Junos OS Evolved ) | 712 Description | 712 Options | 712 Additional Information | 714 Required Privilege Level | 714 Output Fields | 715 Sample Output | 715 Release Information | 716
Syntax
request system software delete software-package <force> <reboot> <set [package-name package-name]> <upgrade-group [all |upgrade-group-name]> <version version-string>
Syntax (TX Matrix Router)
request system software delete software-package <force> <lcc number | scc>

712
<reboot> <set [package-name package-name]>

Syntax (Junos OS Evolved )
request system software delete <force> <package-name> <all-third-party-packages>

Description
Use this command to remove a software package or bundle from the router or switch.
CAUTION: Before removing a software package or bundle, make sure that you have already placed the new software package or bundle that you intend to load onto the router or switch.

Options

package-name

(Only for Junos OS Evolved) Name of the Junos OS Evolved package running on the device. You can see this package name by using the request system software list command. Type the package-name explicitly and do not use the tab key to autocomplete the command.

softwarepackage

(Not available on Junos OS Evolved) Software package or bundle name. You can see this software package name by using the show system software command. Type the software package name explicitly and do not use the tab key to auto-complete the command.

You can delete any or all of the following software bundles or packages:

· jbase--(Optional) Junos base software suite

713

· jcrypto--(Optional, in domestic version only) Junos security software

· jdocs--(Optional) Junos online documentation file

· jkernel--(Optional) Junos kernel software suite

· jpfe--(Optional) Junos Packet Forwarding Engine support

· jroute--(Optional) Junos routing software suite

· junos--(Optional) Junos base software

On EX Series switches, some of the package names are different than those listed. To see the list of packages that you can delete on an EX Series switch, enter the command show system software.

all-third-party- (Junos OS Evolved only) (Optional) Delete all third-party software on the device. packages

force

(Optional) Ignore warnings and force removal of the software.

lcc number

(TX Matrix routers and TX Matrix Plus routers only) (Optional) In a routing matrix, delete a software package or bundle on a T640 router indicated by lcc number that is connected to the TX Matrix router. In a routing matrix, delete a software package or bundle on a router indicated by lcc number that is connected to the TX Matrix Plus router.
Replace number with the following values depending on the LCC configuration:
· 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

· 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

· 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

· 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

re0 | re1

(Optional) On routers or switches that support dual or redundant Routing Engines, delete a software package or bundle on the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

reboot

As of Junos OS 12.3 and greater, automatically reboot upon completing the request system software delete command.

714

scc

(TX Matrix routers only) (Optional) Remove an extension or upgrade package from the

TX Matrix router (or switch-card chassis).

set [packagename packagename] sfc number

(M Series, MX Series, and T Series routers only) (Optional) Install multiple software packages or software add-on packages at the same time.
(TX Matrix Plus routers only) (Optional) Remove an extension or upgrade package from the TX Matrix Plus router. Replace number with 0.

upgradegroup [ all | upgradegroup-name]

(Junos Fusion only) Delete the satellite software image association with the specified satellite software upgrade group.
A satellite software upgrade group is a group of satellite devices in the same Junos Fusion that are designated to upgrade to the same satellite software version using the same satellite software package.

version

(Junos Fusion only) (Optional) Delete a satellite software package association with a

version-string satellite software upgrade group by selecting the satellite software package's version.

Additional Information
Before upgrading the software on the router or switch, when you have a known stable system, issue the request system snapshot command to back up the software, including the configuration, to the /altroot and /altconfig file systems (on routers) or the /, /altroot, /config, /var, and /var/tmp file systems (on switches). After you have upgraded the software on the router or switch and are satisfied that the new packages are successfully installed and running, issue the request system snapshot command again to back up the new software to the /altroot and /altconfig file systems (on routers) or the /, /altroot, / config, /var, and /var/tmp file systems (on switches). After you run the request system snapshot command, you cannot return to the previous version of the software, because the running and backup copies of the software are identical.
Required Privilege Level
maintenance

715
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system software delete jdocs The following example displays the system software packages before and after the jdocs package is deleted through the request system software delete command:
user@host> show system software Information for jbase: Comment: JUNOS Base OS Software Suite [7.2R1.7]
Information for jcrypto: Comment: JUNOS Crypto Software Suite [7.2R1.7]
Information for jdocs: Comment: JUNOS Online Documentation [7.2R1.7]
Information for jkernel: Comment: JUNOS Kernel Software Suite [7.2R1.7] ...
user@host> show system software

716
Information for jbase: Comment: JUNOS Base OS Software Suite [7.2R1.7]
Information for jcrypto: Comment: JUNOS Crypto Software Suite [7.2R1.7]
Information for jkernel: Comment: JUNOS Kernel Software Suite [7.2R1.7] ...
request system software delete (Junos OS Evolved)
user@host> request system software delete junos-evo-install-qfx-fixed-x86-64-18.3I20180911102422 Removing version 'junos-evo-install-qfx-fixed-x86-64-18.3I20180911102422'. Software ... done. Data ... done. Version 'junos-evo-evo-qfx-fixed-x86-64-18.3I20180911102422' removed successfully.
Release Information
Command introduced before Junos OS Release 7.4. sfc option introduced in Junos OS Release 9.6 for the TX Matrix Plus router. set [package-name package-name] option added in Junos OS Release 12.2 for M Series, MX Series, and T Series routers. reboot option introduced in Junos OS Release 12.3. upgrade-group, and version options introduced in Junos OS Release 14.2R3 for Junos Fusion.

717
all-third-party-packages option introduced in Junos OS Evolved Release 19.4R2.
RELATED DOCUMENTATION request system software add | 679 request system software rollback | 726 request system software validate Routing Matrix with a TX Matrix Plus Router Solutions Page
request system software delete-backup
IN THIS SECTION Syntax | 717 Description | 717 Required Privilege Level | 718 Output Fields | 718 Sample Output | 718 Release Information | 718
Syntax
request system software delete-backup
Description
Use this command to delete the backup image previously created. Junos OS keeps a backup image of the software that was previously installed so that you can downgrade to that version of the software if necessary. If you delete this image, you cannot downgrade to the particular version of the software.

718 Note that this command does not perform any function on SRX Series devices with the dual-root partitioning scheme (units that are shipped with Junos OS 10.0 version or later).
Required Privilege Level
maintenance
Output Fields
Sample Output
request system software system-backup
user@host> request system software delete-backup Delete backup system software package [yes,no]
Release Information
Command introduced in Junos OS Release 9.6R1.
RELATED DOCUMENTATION request system software delete | 711

719
request system software download
IN THIS SECTION Syntax (QFabric System) | 719 Description | 719 Options | 719 Additional Information | 720 Required Privilege Level | 720 Output Fields | 720 Sample Output | 720 Release Information | 721
Syntax (QFabric System)
request system software download path package-name
Description
Use this command to download a software package from a location on the director device, mounted external USB flash drive, remote FTP or SCP location, or other location.
Options
path Location where the software package is located. For example: · /pbdata/packages/package-name--For a software package that is being installed from a local directory on the switch.

720
· protocol://hostname/pathname/package-name--For a software package or bundle that is to be downloaded and installed from a remote location. Replace protocol with one of the following: · ftp--File Transfer Protocol. Use ftp://hostname/pathname/package-name. To specify authentication credentials, use ftp://<username>:<password>@hostname/pathname/package-name. To have the system prompt you for the password, specify prompt in place of the password. If a password is required, and you do not specify the password or prompt, an error message is displayed. · scp--Secure copy (available only for Canada and U.S. version). Use scp://hostname/pathname/package-name. To specify authentication credentials, use scp://<username>:<password>@hostname/pathname/package-name.
Additional Information
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system software download
user@switch> request system software download ftp://ftp.install-directory/jinstallqfabric-11.3X30.6.rpm

721

% Total 100 186M

% Received % Xferd

100 186M 0

0

Average Speed Time

Dload Upload Total

18.4M

0 0:00:10

Time

Time Current

Spent Left Speed

0:00:10 --:--:-- 18.6M

Release Information
Command introduced in Junos OS Release 11.3.
RELATED DOCUMENTATION request system software add | 679 request system software delete | 711 request system software rollback | 726 request system storage cleanup | 754 Installing Software Packages on QFX Series Devices | 151
request system software recover-from-restore-point

IN THIS SECTION
Syntax | 722 Description | 722 Required Privilege Level | 722 Sample Output | 722 Release Information | 723

722
Syntax
request system software recover-from-restore-point
Description
Use to command to rollback to a previously created restore-point. Rolling back to a previously created restore-point might disrupt traffic, as both Director devices reboot from the restore-point partition.
Required Privilege Level
configure
Sample Output
request system software recover-from-restore-point
root@qfabric> request system software recover-from-restore-point Start Restore Checking if the restore-point exists
LogVol00 has the root filesystem Found Restore-Point: Fri Aug 15 07:42:39 UTC 2014 /dev/VolGroup00/LogVol03 Mounting restore-volume LogVol03 Checking the sanity of restore-point Checking if the restore DB is present Checking if the restore grub is present Checking the current state of the system Checking the state of cluster services Checking the inventory Checking if the peer is reachable Checking if peer is reachable via Compute Node Monitor

723
Successfully communicated with peer over 169.254.0.2 Intimating the peer to do stage INITIATE_PEER_INITIAL_STAGE of downgrade Preparing the system to downgrade Prepping all Junos devices Checking status at Peer
Downgrade first stage at peer concluded successfully Initiating final stage of downgrade in peer Intimating the peer to do stage INITIATE_PEER_FINAL_STAGE of downgrade Modify loader to boot from restore-point Move mount points to new filesystem Force Reboot Rebooting....
Release Information
Command introduced in Junos OS Release 14.1X53-D15.
RELATED DOCUMENTATION request system software restore-point | 723
request system software restore-point
IN THIS SECTION Syntax | 724 Description | 724 Required Privilege Level | 724 Sample Output | 724 Release Information | 726

724
Syntax
request system software restore-point
Description
Use this command to create a restore-point. A restore-point is a snapshot of the software on the QFabric system as well as the configuration that can be rolled back to in cases where a software upgrade or configuration changes have made the QFabric system unstable or inoperable.
Required Privilege Level
configure
Sample Output
request system software restore-point
root@qfabric> request system software restore-point Checking if director-device upgrade is currently in progress. Checking VM status. Checking for communication between director devices. Checking inventory status of all components. Checking Server INE passwords. Checking FC passwords. Checking CCPC passwords. Checking FM-0 passwords. Checking DRE-0 passwords. Checking NW-NG-0 passwords. Checking chassis alarms. 0 sent command to peer to start operation sanity checks passed

725

Performing fdisk

restore partition created

creating restore partition on physical disk

device /dev/sda: start 0 size -388718592

gpt: 0 slices

dos: 4 slices

# 1:

63- 208844 ( 208782 sectors, 106 MB)

# 2: 208845-1048771394 (1048562550 sectors, 536864 MB)

# 3: 1048771395-1146446594 ( 97675200 sectors, 50009 MB)

# 4: 1146446595-2146460714 (1000014120 sectors, 512007 MB)

performing physical volume creation

Physical volume "/dev/sda4" successfully created

"/dev/sda4" is a new physical volume of "476.84 GB"

PV Name

/dev/sda4

extending volume group 00

Volume group "VolGroup00" successfully extended

Creating Logical Volume

Logical volume "LogVol03" created

LV Name

/dev/VolGroup00/LogVol03

Restore volume selected is /dev/VolGroup00/LogVol03

Formatting restore volume

mke2fs 1.39 (29-May-2006)

Filesystem label=

OS type: Linux

Block size=4096 (log=2)

Fragment size=4096 (log=2)

62504960 inodes, 124993536 blocks

6249676 blocks (5.00%) reserved for the super user

First data block=0

Maximum filesystem blocks=4294967296

3815 block groups

32768 blocks per group, 32768 fragments per group

16384 inodes per group

Superblock backups stored on blocks:

32768, 98304, 163840, 229376, 294912, 819200, 884736, 1605632, 2654208,

4096000, 7962624, 11239424, 20480000, 23887872, 71663616, 78675968,

102400000

Creating journal (32768 blocks): done Writing superblocks and filesystem accounting information: done

This filesystem will be automatically checked every 22 mounts or 180 days, whichever comes first. Use tune2fs -c or -i to override.

726
/dev/VolGroup00/LogVol03: UUID="a9fafbaf-da3c-417f-bd53-def01fbf3936" SEC_TYPE="ext2" TYPE="ext3" Restore Volume mounted backing up root filesystem..this will take a few minutes Copying files from tmp..this may take a few minutes Dumping databases...this may take a few minutes backing up shared filesystem..this may take a few minutes Restore point creation finished for dg0 on /dev/VolGroup00/LogVol03 waiting 10 mins for for peer dg to finish Restore point creation success on both DGs
Release Information
Command introduced in Junos OS Release 14.1X53-D15.
RELATED DOCUMENTATION request system software recover-from-restore-point | 721
request system software rollback
IN THIS SECTION Syntax | 727 Syntax (EX Series Switches) | 727 Syntax (TX Matrix Router) | 727 Syntax (TX Matrix Plus Router) | 728 Syntax (MX Series Router) | 728 Syntax (Junos OS Evolved) | 728 Description | 728 Options | 729 Required Privilege Level | 731

727
Output Fields | 731 Sample Output | 731 Release Information | 732
Syntax
request system software rollback
Syntax (EX Series Switches)
request system software rollback <all-members> <local> <member member-id> <reboot>
Syntax (TX Matrix Router)
request system software rollback <lcc number | scc> <reboot>

728
Syntax (TX Matrix Plus Router)
request system software rollback <lcc number | sfc number> <reboot>
Syntax (MX Series Router)
request system software rollback <all-members> <device-alias alias-name> <local> <member member-id <reboot> <satellite slot-id> <upgrade-group [all |upgrade-group-name]>
Syntax (Junos OS Evolved)
request system software rollback <no-validate> <package-name> <reboot> <validate> <with-old-snapshot-config>
Description
Use this command to revert to the last successfully installed package before the request system software (add | delete) command. It uses the copy stored in the /var/sw/pkg directory. Additional Information

729
· On Junos Fusion, the request system software rollback command can be used to roll back the version of satellite software associated with a satellite software upgrade group. Rolling back the version of satellite software associated with a satellite software upgrade group triggers a satellite software upgrade.
· On M Series and T Series routers, if request system software add <jinstall> reboot was used for the previous installation, then request system software rollback has no effect. In this case, use jinstall to reinstall the required package.
· On M Series and T Series routers, if request system software add <sdk1> was used for the previous installation, then request system software rollback removes the last installed SDK package (sdk1 in this example).
· On SRX Series devices with dual root systems, when request system software rollback is run, the system switches to the alternate root. Each root can have a different version of Junos OS. Roll back takes each root back to the previously installed image.
· On QFX3500 and QFX3600 devices in a mixed Virtual Chassis, when the request system software rollback command is issued, the system does not rollback to the image stored in the alternate partition.
· On QFX5100 switches, the reboot option has been removed. To reboot the switch after a software rollback, issue the request system reboot command as a separate, secondary command.
· On Junos OS Evolved, the reboot command is required in order to complete the rollback.

Options

all-members
device-alias alias-name lcc number

(EX4200 switches and MX Series routers only) (Optional) Attempt to roll back to the previous set of packages on all members of the Virtual Chassis configuration.
(Junos Fusion only) (Optional) Rollback the satellite software package onto the specified satellite device using the satellite devices FPC slot identifier.
(TX Matrix routers and TX Matrix Plus routers only) (Optional) On a TX Matrix router, attempt to roll back to the previous set of packages on a T640 router connected to the TX Matrix router. On a TX Matrix Plus router, attempt to roll back to the previous set of packages on a connected router connected to the TX Matrix Plus router.
Replace number with the following values depending on the LCC configuration:

730

· 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

· 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

· 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

· 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

local

(EX4200 switches and MX Series routers only) (Optional) Attempt to roll back to the previous set of packages on the local Virtual Chassis member.

member member-id

(EX4200 switches and MX Series routers only) (Optional) Attempt to roll back to the previous set of packages on the specified member of the Virtual Chassis configuration. For EX4200 switches, replace member-id with a value from 0 through 9. For an MX Series Virtual Chassis, replace member-id with a value of 0 or 1.

no-validate | validate none

(Only for Junos OS Evolved) Check compatibility with current configuration, yes or no.
For all versions of Junos OS up to and including Junos OS 11.4, revert to the set of software as of the last successful request system software add. As of Junos OS 12.1 and later, revert to the last known good state before the most recent request system software (add | delete) command.

package-name version

(Junos OS Evolved only) Select any installed version for the rollback. The request system software rollback command uses the version instead of the package-name. you can see the available versions by using the show system software list command. If a version is not specified, the system rolls back to the default rollback version (the one with the '<' before it on the show system software list command output). You can specify any previous Junos OS Evolved release as long as it is not the one that is currently running or the rollback version.

reboot

(Optional) For Junos OS 12.3 and later, the system reboots automatically to complete the rollback. However, for Junos OS Evolved, you must explicitly specify the reboot option to complete the rollback.

satellite slot-id (Junos Fusion only) (Optional) Roll back the satellite software package onto the specified satellite device using the satellite devices FPC slot identifier.

scc

(TX Matrix routers only) (Optional) Attempt to roll back to the previous set of packages

on the TX Matrix router (or switch-card chassis).

731

sfc number

(TX Matrix Plus routers only) (Optional) Attempt to roll back to the previous set of packages on the TX Matrix Plus router. Replace number with 0.

upgrade-group [ all |upgradegroup-name]

(Junos Fusion only) Roll back the satellite software image associated with the specified satellite software upgrade group, or for all satellite software upgrade groups in the Junos Fusion when all is entered.

validate | novalidate with-oldsnapshotconfig

(Junos OS Evolved only).
(Optional) (Junos OS Evolved only) Rolls back system to the specified version with the old snapshot of the configuration used in that version. Otherwise, the rollback, by default, takes the current configuration.

Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system software rollback
user@host> request system software rollback Verified SHA1 checksum of ./jbase-7.2R1.7.tgz Verified SHA1 checksum of ./jdocs-7.2R1.7.tgz Verified SHA1 checksum of ./jroute-7.2R1.7.tgz Installing package './jbase-7.2R1.7.tgz' ... Available space: 35495 require: 7335 Installing package './jdocs-7.2R1.7.tgz' ... Available space: 35339 require: 3497 Installing package './jroute-7.2R1.7.tgz' ... Available space: 35238 require: 6976

732
NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.preinstall Reloading /config/juniper.conf.gz ... Activating /config/juniper.conf.gz ... mgd: commit complete Restarting mgd ... Restarting aprobed ... Restarting apsd ... Restarting cosd ... Restarting fsad ... Restarting fud ... Restarting gcdrd ... Restarting ilmid ... Restarting irsd ... Restarting l2tpd ... Restarting mib2d ... Restarting nasd ... Restarting pppoed ... Restarting rdd ... Restarting rmopd ... Restarting rtspd ... Restarting sampled ... Restarting serviced ... Restarting snmpd ... Restarting spd ... Restarting vrrpd ...
WARNING: cli has been replaced by an updated version: CLI release 7.2R1.7 built by builder on 2005-04-22 02:03:44 UTC Restart cli using the new version ? [yes,no] (yes) yes
Restarting cli ... user@host
Release Information
Command introduced before Junos OS Release 7.4.
sfc option introduced in Junos OS Release 9.6 for the TX Matrix Plus router.
Command behavior changed in Junos OS Release 12.1.

733
reboot option introduced in Junos OS Release 12.3. device-alias, satellite, and upgrade-group options introduced in Junos OS Release 14.2R3 for Junos Fusion. force option deprecated in Junos OS Release 15.1 for Junos OS with Upgraded FreeBSD. To determine which platforms run Junos OS with Upgraded FreeBSD, see the table listing the platforms currently running Junos OS with upgraded FreeBSD in Release Information for Junos OS with Upgraded FreeBSD. validate and no-validate options introduced for Junos OS Evolved Release 18.3R1. package-name version option introduced for Junos OS Evolved Release 18.3R1. with-old-snapshot-config option introduced for Junos OS Evolved Release 18.3R1.
RELATED DOCUMENTATION request system software abort request system software add | 679 request system software delete | 711 request system software validate request system configuration rescue delete request system configuration rescue save Routing Matrix with a TX Matrix Plus Router Solutions Page
request system software rollback (SRX Series)
IN THIS SECTION Syntax | 734 Description | 734 Options | 734 Required Privilege Level | 734 Release Information | 734

734
Syntax
request system software rollback <node-id>
Description
Use this command to revert to the software that was loaded at the last successful request system software add command. The upgraded FreeBSD 11.x (supported in Junos OS Release 17.4R1) Junos OS image provides an option to save a recovery image in an Operation, Administration, and Maintenance (OAM) partition, but that option will save only the Junos OS image, not the Linux image. If a user saves the Junos OS image and recovers it later, it might not be compatible with the Linux software loaded on the system.
Options
node-id--Identification number of the chassis cluster node. It can be 0 or 1.
Required Privilege Level
maintenance
Release Information
Command introduced in Junos OS Release 10.1.
RELATED DOCUMENTATION Upgrading Junos OS with Upgraded FreeBSD | 265 Release Information for Junos OS with Upgraded FreeBSD

735
request system software sync
IN THIS SECTION Syntax | 735 Description | 735 Options | 735 Additional Information | 736 Required Privilege Level | 736 Sample Output | 737 Release Information | 741

Syntax
request system software sync (current | rollback | all-versions)

Description
Use this command on the primary Routing Engine of a cluster to synchronize the software and configurations from the primary node to the other nodes and reboot the other nodes. The configurations are synchronized even if the images are identical. If specified on the backup RE, the command fails.

Options

current | rollback | all-versions

Specify which software version (current or rollback) to sync to the other node:

736
· For the current option, system syncs the current version to the other node and reboots with that version. If the current version on the master RE of the cluster matches the version on RE1 of the system, the command fails.
· For the rollback option, the system syncs the rollback version to the other node. If the rollback version on the master RE of the cluster matches the rollback version on RE1 of the system, the commands fails.
· For the all-versions option, the system syncs all software versions to the other node and reboots if there's a mismatch between current versions.
Additional Information
For the all-versions option, the synchronization proceeds as follows: 1. All versions are deleted, except for the current version on RE1. 2. The current and rollback images and configuration are copied to RE1. Even if the software versions
match, the configuration is copied and the software proceeds to the next image. 3. Any other versions and configurations are copied from RE0 to RE1. 4. If the current version on RE1 is not the same as current on RE0, then RE1 is rebooted after warning
the user. The command is successful if the first two steps of the synchronization are successful. If step 3 fails, a warning message is displayed. To make the versions match, you can delete the extra versions using the request system software delete operational mode command. To see what the software versions on the device are, use the request system software list command.
Required Privilege Level
view

737
Sample Output
request system software sync current
user@host> request system software sync current Cleanup old software versions on re1
Removing version junos-evo-install-qfx-x86-64-16.2I20170625192110... Done. Transfer software version files for junos-evo-install-qfxx86-64-16.2I20170626030132 to node re1... Setting up software version files for junos-evo-install-qfxx86-64-16.2I20170626030132 on re1
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImagere-64b.bin linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_uImage-ptxpmbp2020.bin linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImagejnx_fpc_0bf9.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImagejnx_fpc_0bfa.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImagejnx_spmb_0c2b.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImage-ptx21krcb.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImage-ptx5kmtrcb.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImage-ptx5krcb.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_uImageptxpmb_p2020.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_uImageptxpmb_p2020_spmb.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_ccd-ptxfpc64_Yocto_1.8_x86_64_fpc.fs linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_ccd-ptxfpc_Yocto_1.8_p2020.fs linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_ccd-ptxre64_Yocto_1.8_x86_64.fs linked
/soft/junos-evo-install-qfxx86-64-16.2I20170626030132_dev_Yocto_1.8_p2020.fs linked
/soft/junos-evo-install-qfx-

738
x86-64-16.2I20170626030132_dev_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_dev_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_initramfs_Yocto_1.8_p2020.fs copied /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_initrd_Yocto_1.8_p2020.fs copied /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_initrd_Yocto_1.8_x86_64.fs copied /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_initrd_Yocto_1.8_x86_64_fpc.fs copied /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_java_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_jimbase_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_jimbase_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_jimbase_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_modules_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_modules_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_modules_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_osbase_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_osbase_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_osbase_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_perl-5.20.0_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_python-2.7_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_python-2.7_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_python-2.7_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_python-3.3_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_zookeeper_Yocto_1.8_x86_64.fs linked

739
Set version junos-evo-install-qfx-x86-64-16.2I20170626030132_tchittar as nextboot
Installing for i386-pc platform. Installation finished. No error reported. Boot version is now 'junos-evo-install-qfx-x86-64-16.2I20170626030132' Rebooting re1 Shutdown at Mon Jun 26 03:24:08 2017
request system software sync rollback
user@host> request system software sync rollback Cleanup old software versions on re1
Removing version junos-evo-install-qfx-x86-64-16.2I20170625192110... Done. Transfer software version files for junos-evo-install-qfxx86-64-16.2I20170626030132 to node re1... Setting up software version files for junos-evo-install-qfxx86-64-16.2I20170626030132 on re1
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImagere-64b.bin linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_uImage-ptxpmbp2020.bin linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImagejnx_fpc_0bf9.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImagejnx_fpc_0bfa.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImagejnx_spmb_0c2b.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImage-ptx21krcb.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImage-ptx5kmtrcb.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_bzImage-ptx5krcb.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_uImageptxpmb_p2020.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_uImageptxpmb_p2020_spmb.dtb linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_ccd-ptxfpc64_Yocto_1.8_x86_64_fpc.fs linked
/soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_ccd-ptx-

740
fpc_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-x86-64-16.2I20170626030132_ccd-ptx-
re64_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_dev_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_dev_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_dev_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_initramfs_Yocto_1.8_p2020.fs copied /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_initrd_Yocto_1.8_p2020.fs copied /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_initrd_Yocto_1.8_x86_64.fs copied /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_initrd_Yocto_1.8_x86_64_fpc.fs copied /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_java_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_jimbase_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_jimbase_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_jimbase_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_modules_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_modules_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_modules_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_osbase_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_osbase_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_osbase_Yocto_1.8_x86_64_fpc.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_perl-5.20.0_Yocto_1.8_x86_64.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_python-2.7_Yocto_1.8_p2020.fs linked /soft/junos-evo-install-qfx-
x86-64-16.2I20170626030132_python-2.7_Yocto_1.8_x86_64.fs linked

741
/soft/junos-evo-install-qfxx86-64-16.2I20170626030132_python-2.7_Yocto_1.8_x86_64_fpc.fs linked
/soft/junos-evo-install-qfxx86-64-16.2I20170626030132_python-3.3_Yocto_1.8_x86_64.fs linked
/soft/junos-evo-install-qfxx86-64-16.2I20170626030132_zookeeper_Yocto_1.8_x86_64.fs linked
Set version junos-evo-install-qfx-x86-64-16.2I20170626030132 as nextboot Installing for i386-pc platform. Installation finished. No error reported. Boot version is now 'junos-evo-install-qfx-x86-64-16.2I20170626030132' Rebooting re1 Shutdown at Mon Jun 26 03:24:08 2017
Release Information
Command introduced in Junos OS Evolved Release 18.3R1.
RELATED DOCUMENTATION show system software list | 845 request system software rollback (Junos OS Evolved) | 0
request system software validate
IN THIS SECTION Syntax | 742 Syntax (TX Matrix Router) | 742 Syntax (TX Matrix Plus Router) | 742 Syntax (MX Series Router) | 743 Syntax (Junos OS Evolved) | 743 Description | 743

742
Options | 743 Additional Information | 745 Required Privilege Level | 745 Output Fields | 745 Sample Output | 746 Release Information | 747
Syntax
request system software validate package-name <on (host host <username username> | routing-engine routing-engine)> <set [package-name package-name]> <upgrade-with-config> <upgrade-with-config-format format>
Syntax (TX Matrix Router)
request system software validate package-name <lcc number | scc> <on (host host <username username> | routing-engine routing-engine)> <set [package-name package-name]> <upgrade-with-config> <upgrade-with-config-format format>
Syntax (TX Matrix Plus Router)
request system software validate package-name <lcc number | sfc number> <on (host host <username username> | routing-engine routing-engine)>

743
<set [package-name package-name]> <upgrade-with-config> <upgrade-with-config-format format>

Syntax (MX Series Router)
request system software validate <package-name> <member member-id> <on (host host <username username> | routing-engine routing-engine)> <set [package-name package-name]> <upgrade-with-config> <upgrade-with-config-format format>

Syntax (Junos OS Evolved)
request system software validate package-name <restart>

Description
Use this command to validate candidate software against the current configuration of the router, the switch,or a remote host.

Options
lcc number

(TX Matrix routers and TX Matrix Plus routers only) (Optional) On a TX Matrix router, validate the software bundle or package on a specific T640 router (or linecard chassis) that is connected to the TX Matrix router. On a TX Matrix Plus router, validate the software bundle or package for a specific router that is connected to the TX Matrix Plus router.

744

Replace number with the following values depending on the LCC configuration:
· 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

· 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

· 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

· 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

on (host host<username username> | routing-engine routing-engine)

(Optional) Validate the software bundle or package by comparing it to the running configuration on a remote host or Routing Engine. Specify either a host, replacing host with the remote hostname, or a Routing Engine, replacing routing-engine with the Routing Engine name. If you specify a remote host, you can optionally provide the username to be used to log in to the remote host.

member member-id

(MX Series routers only) (Optional) Validate the software bundle or package on the specified member of the Virtual Chassis configuration. For an MX Series Virtual Chassis, replace member-id with a value of 0 or 1.

package-name

Name of the software bundle or package to test.

restart

(For Junos OS Evolved only) (Optional). Verify the new software configuration compatibility. It emits the list of services which may get restarted when user issues this command.

scc

(TX Matrix routers only) (Optional) Validate the software bundle or package for

the TX Matrix router (or switch-card chassis).

set [packagenamepackagename] sfc number

(M Series, MX Series, T Series routers) (Optional) Install multiple software packages or software add-on packages at the same time.
(TX Matrix Plus routers only) (Optional) Validate the software bundle or package for the TX Matrix Plus router.

upgrade-withconfig upgrade-withconfig-format format

(Optional) Install one or more configuration files.
(Optional) Specify the configuration file fomat, text or xml. The default format is text.

745
The upgrade-with-config and upgrade-with-config-format options are only available locally on the router or switch. In a routing matrix, the configuration is applied only to the local router and is not propagated to other routers. The options are validated during the validation process and applied to the router or switch during the upgrade process. If the upgrade process is successful, the options are removed from the configuration. If the upgrade process fails, the configuration file is renamed with the .failed suffix.
Additional Information
By default, when you issue the request system software validate command on a TX Matrix primary Routing Engine, all the T640 primary Routing Engines that are connected to it are validated. If you issue the same command on the TX Matrix backup Routing Engine, all the T640 backup Routing Engines that are connected to it are upgraded to the same version of software. Likewise, if you issue the request system software validate command on a TX Matrix Plus primary Routing Engine, all the T1600 or T4000 primary Routing Engines that are connected to it are validated. If you issue the same command on a TX Matrix Plus backup Routing Engine, all the T1600 or T4000 backup Routing Engines that are connected to it are upgraded to the same version of software.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.

746
Sample Output
request system software validate (Successful Case)
user@host> request system software validate /var/sw/pkg/ jbundle-5.3I20020124_0520_sjg.tgz Checking compatibility with configuration Initializing... Using /packages/jbase-5.3I20020122_1901_sjg Using /var/sw/pkg/jbundle-5.3I20020124_0520_sjg.tgz Using /var/chroot/var/tmp/jbundle/jbase-5.3I20020124_0520_sjg.tgz Using /var/chroot/var/tmp/jbundle/jkernel-5.3I20020124_0520_sjg.tgz Using /var/chroot/var/tmp/jbundle/jcrypto-5.3I20020124_0520_sjg.tgz Using /var/chroot/var/tmp/jbundle/jpfe-5.3I20020124_0520_sjg.tgz Using /var/chroot/var/tmp/jbundle/jdocs-5.3I20020124_0520_sjg.tgz Using /var/chroot/var/tmp/jbundle/jroute-5.3I20020124_0520_sjg.tgz Validating against /config/juniper.conf.gz mgd: commit complete
WARNING: cli has been replaced by an updated version: CLI release 5.3I0 built by sjg on 2002-01-24 05:23:53 UTC Restart cli using the new version ? [yes,no] (yes)
request system software validate (Failure Case)
user@host> request system software validate 6.3/ Pushing bundle to lcc0-re0 error: Failed to transfer package to lcc0-re0
user@host> request system software validate test Pushing bundle to lcc0-re0 Pushing bundle to lcc2-re0
lcc0-re0: gzip: stdin: not in gzip format tar: child returned status 1 ERROR: Not a valid package: /var/tmp/test

747
Release Information
Command introduced before Junos OS Release 7.4. sfc option introduced for the TX Matrix Plus router in Junos OS Release 9.6. set [package-namepackage-name] option added in Junos OS Release 12.2 for M Series, MX Series, T Series routers. upgrade-with-config and upgrade-with-config-format format options added in Junos OS Release 12.3 for M Series routers, MX Series routers, and T Series routers. on (host host<username username> | routing-engine routing-engine) option introduced in Junos OS Release 13.3, Junos OS Release 14.1, and Junos OS Release 15.1. set [package-namepackage-name] option deprecated in Junos OS Evolved 18.3R1. restart option added in Junos OS Evolved Release 18.3R1.
RELATED DOCUMENTATION request system software validate in-service-upgrade request system software abort request system software add | 679 request system software delete | 711 request system software rollback | 726 Routing Matrix with a TX Matrix Plus Router Solutions Page
request system software validate on (Junos OS with Upgraded FreeBSD)
IN THIS SECTION Syntax | 748 Description | 748

748
Options | 748 Additional Information | 749 Required Privilege Level | 749 Output Fields | 749 Sample Output | 749 Release Information | 751

Syntax
request system software validate on <host host-name [ username user-name ]> <routing-engine (re0 | re1)>

Description
Use this command to validate the current configuration on a Routing Engine that is not running Junos OS with upgraded FreeBSD or a remote host.
Direct validation of a running configuration is not possible on a device running Junos OS with upgraded FreeBSD. Nevertheless, validation is an important step in the installation of an upgraded operating system. This command allows validation on a device that is not running Junos OS with upgraded FreeBSD.

Options

The specific options available are:

host host-name [ username username ]

Validate the current configuration on a remote host. The host-name is resolved through DNS. Optionally, you can supply a username to employ on the remote host. If you omit the username option, the currently logged-in user-name is sent to the remote host.

749

routing-engine (re0 | re1)

Validate the current configuration on another Routing Engine on the same device. The other Routing Engine cannot be running Junos OS with upgraded FreeBSD or the validation does not succeed.

Additional Information
If the authenticity of the remote host cannot be established, you are prompted to continue the validation or not. If you choose not to continue, the validation process does not take place.
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request system software validate on host
user@host> request system software validate on host remote-validator The authenticity of host 'remote-validator (192.168.164.174)' can't be established. ECDSA key fingerprint is 73:d0:78:ce:8d:09:aa:92:4c:ce:45:52:1d:76:86:b5. Are you sure you want to continue connecting (yes/no)? yes Password: **********
Sending /var/tmp/config.tgz to remote-validator... Validating /var/tmp/config.tgz on remote-validator... Checking compatibility with configuration Initializing...

750
Using jbase-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jruntime-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jkernel-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jroute-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jcrypto-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jweb-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using /var/tmp/config.tgz Hardware Database regeneration succeeded Validating against /config/juniper.conf.gz mgd: warning: schema: init: 'logical-systems-vlans' contains-node 'juniperconfig vlans': not found mgd: commit complete Validation succeeded
request system software validate on routing-engine
user@host> request system software validate on routing-engine re1
Sending /var/tmp/config.tgz to re1... Validating /var/tmp/config.tgz on re1... Checking compatibility with configuration Initializing... Using jbase-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jruntime-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jkernel-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jroute-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jcrypto-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using jweb-15.1-20150416.2 Verified manifest signed by PackageDevelopmentEc_2015 Using /var/tmp/config.tgz

751
Hardware Database regeneration succeeded Validating against /config/juniper.conf.gz mgd: warning: schema: init: 'logical-systems-vlans' contains-node 'juniperconfig vlans': not found mgd: commit complete Validation succeeded
Release Information
Command introduced in Junos OS Release 15.1 for supported platforms. See Feature Explorer.
RELATED DOCUMENTATION request system reboot (Junos OS with Upgraded FreeBSD) | 643 show system snapshot (Junos OS with Upgraded FreeBSD) | 838 Release Information for Junos OS with Upgraded FreeBSD
request system software validate-restart
IN THIS SECTION Syntax | 752 Description | 752 Options | 752 Required Privilege Level | 752 Sample Output | 752 Release Information | 754

752
Syntax
request system software validate-restart package-name

Description
Use this command to verify new package with current configuration to get application restart and reboot compatibility. Use this command before you run request system software add restart.

Options
package-name

Path and filename of the software package to be installed.

Required Privilege Level
view
Sample Output
request system software validate-restart (fixed form platforms)
user@host> request system software validate-restart /var/tmp/qfx-ms-fixed-1-target1-ifmanarpcos.iso validate-restart Validating software image and getting ISSU services impact /var/tmp/qfx-msfixed-1-target1-ifmanarpcos.iso... Download and Validate in Progress re0: Starting software validation for /var/tmp/qfx-ms-fixed-1-target1ifmanarpcos.iso re0: This process can take several minutes. Please be patient... [ 2631.326645] ICMPv6: RA: ndisc_router_discovery failed to add default route [ 2648.292906] disk_mgmt_tool.py[7812]: 2019-05-24 18:31:29 INFO: /var is

753
running high on usage, 74% used of 15G re0: Installing IMA keys of the incoming ISO image... re0: Validating existing configs. See /var/log/validation_config.log for config validation logs. re0: Config validation Success. Getting ISSU impact report. Can take few more minutes... [ 2717.155661] ICMPv6: RA: ndisc_router_discovery failed to add default route re0: Removing version junos-evo-install-qfx-ms-fixed-x86-64-19.2R1-20190522.4EVOI20190523235333-gsanka-1... re0: Validation for version junos-evo-install-qfx-ms-fixedx86-64-19.2R1-20190522.4-EVOI20190523235333-gsanka-1 completed Image validation succeeded. ISSU impact report:
*** Restart Apps list *** arpd ifmand cosd Image validation succeeded.
request system software validate-restart (chassis-based platforms)
user@host> request system software validate-restart /var/tmp/a.iso validate-restart *** List of Offlined FPCs *** FPC0 FPC1 FPC2
Please perform online for above FPCs.
*** List of Incompatible FPCs ***
FPC0 FPC1
Warning: Please perform offline for above FPCs.
*** List of Incompatible configurations ***
"system services subscriber-management enable"

754
Warning: Please perform deactivation of the above configurations.
*** Restart Apps list *** sysman ifmand arpd Image validation succeeded. user@host>
Release Information
Command introduced in Junos OS Evolved Release 19.1R2.
RELATED DOCUMENTATION request system software add (Junos OS Evolved) | 0
request system storage cleanup
IN THIS SECTION Syntax | 755 Syntax (EX Series Switches) | 755 Syntax (MX Series Router) | 755 Syntax (QFX Series) | 756 Syntax (SRX Series) | 756 Syntax (Junos OS Evolved) | 756 Description | 757 Options | 757

755
Additional Information | 759 Required Privilege Level | 759 Output Fields | 759 Sample Output | 760 Release Information | 776
Syntax
request system storage cleanup <dry-run> <no-confirm> <re0 | re1 | routing-engine (backup | both | local | master | other)>
Syntax (EX Series Switches)
request system storage cleanup <all-members> <dry-run> <local> <member member-id> <no-confirm> <re0 | re1 | routing-engine (backup | both | local | master | other)> <satellite [slot-id slot-id |device-alias alias-name]>
Syntax (MX Series Router)
request system storage cleanup <all-members> <dry-run> <local>

756
<member member-id> <no-confirm> <re0 | re1 | routing-engine (backup | both | local | master | other)> <satellite [slot-id slot-id |device-alias alias-name]>
Syntax (QFX Series)
request system storage cleanup <component (serial number | UUID | all)> <director-group name> <dry-run> <infrastructure name> <interconnect-device name> <name-tag name-tag> <no-confirm> <node-group name> <prune> <qfabric (component name) | dry-run | name-tag | repository)> <repository (core | log)> <re0 | re1 | routing-engine (backup | both | local | master | other)>
Syntax (SRX Series)
request system storage cleanup <dry-run> <no-confirm> <re0 | re1 | routing-engine (backup | both | local | master | other)>
Syntax (Junos OS Evolved)
request system storage cleanup (dry-run | force-deep | no-confirm)

757
Description
Use this command to free storage space on the router or switch by rotating log files and proposing a list of files for deletion. On a QFabric system, you can delete debug files located on individual devices or on the entire QFabric system.
The Junos OS Evolved implementation of the request system storage cleanup command is slightly different from the implementation on Junos OS:
· You are prompted to specify the dry-run option:
Please check the list of files to be deleted using the dry-run option. Continue anyway without checking? [yes,no] (yes)
· When request system storage cleanup is executed, Junos OS Evolved displays the types of files that are being deleted. See the Sample Output section below for an example.
· Prior to Junos OS Evolved Release 20.1R1, the command cleans up any ISO files on the system, rotates syslogs, and clears trace files. It does not remove user-created files. Starting in Junos OS Evolved Release 20.1R1, this command does not remove ISO images from the system. It removes all core files, log files from /var/log/, and all /var/log/* files. To remove old images from the device, use the request system software delete command.
· In Junos OS Evolved, the system computes the available space and emits o/p on console for reference.
In Junos OS Evolved, the request system storage cleanup | display xml rpc command displays different XML tags for different file types. In Junos OS, only the file tag is displayed for all types of files. For more information about the differences between Junos OS and Junos OS Evolved, see How Junos OS Evolved Differs from Junos OS.

Options
all-members

(EX4200 switches and MX Series routers only) (Optional) Delete files on the Virtual Chassis primary Routing Engine only.
To delete files on the other members of the Virtual Chassis configuration, log in to each backup Routing Engine and delete the files using the request system storage cleanup local command.

758

component (UUID | serial number | all)

(QFabric systems only) (Optional) Delete files located on individual QFabric system devices or on the entire QFabric system.

director-group name (QFabric systems only) (Optional) Delete files on the director group.

dry-run

(Optional) List files proposed for deletion (without deleting them).

force-deep

(Junos OS Evolved only) Deep clean all temporary files and rotate logs. This option cleans up all the user-created files under /tmp and /var/tmp directories.

infrastructure name

(QFabric systems only) (Optional) Delete files on the fabric control Routing Engine and fabric manager Routing Engine.

interconnect-device name local

(QFabric systems only) Optional) Delete files on the Interconnect device.
(EX4200 switches and MX Series routers only) (Optional) Delete files on the local Virtual Chassis member.

member member-id

(EX4200 switches and MX Series routers only) (Optional) Delete files on the specified member of the Virtual Chassis configuration. For EX4200 switches, replace member-id with a value from 0 through 9. For an MX Series Virtual Chassis, replace member-id with a value of 0 or 1.

name-tag name-tag

(QFabric systems only) (Optional) Delete debug files that match a specific regular expression.

node-group name

(QFabric systems only) (Optional) Delete files on the Node group.

no-confirm

(Optional) Do not ask for confirmation before doing the cleanup.

prune

(QFabric systems only) (Optional) Delete debug files located in either the core or log debug repositories of a QFabric system device.

qfabric component name

(QFabric systems only) (Optional) Delete debug files located in the debug repositories of a QFabric system device.

(re0 | re1 | routingengine (backup | both | local | master | other))

(Optional) Request operation on system storage on RE0, RE1, or on specified Routing Engine by these classifications: backup, both, local, primary, or other.
When Routing Engine is specified, the below message is shown before listing the files and deleting them.

Please check the list of files to be deleted using the dryrun option. i.e.

759

request system storage cleanup dry-run Do you want to proceed ? [yes,no] (no)

repository (core | log)

(QFabric systems only) (Optional) Specify the repository on the QFabric system device for which you want to delete debug files.

satellite [slot-id slot-id | device-alias aliasname]

(Junos Fusion only) (Optional) Specify the satellite device in the Junos Fusion by FPC ID or device alias name for which you want to delete debug files.

Additional Information
If logging is configured and being used, the dry-run option rotates the log files. In that case, the output displays the message "Currently rotating log files, please wait." If no logging is currently under way, the output displays only a list of files to delete.

Required Privilege Level
maintenance

Output Fields

Table 28 on page 759 describes the output fields for the request system storage cleanup command. Output fields are listed in the approximate order in which they appear.
Table 28: request system storage cleanup Output Fields

Field Name

Field Description

List of files to delete:

Shows list of files available for deletion.

Size

Size of the core-dump file.

760

Table 28: request system storage cleanup Output Fields (Continued)

Field Name

Field Description

Date

Last core-dump file modification date and time.

Name

Name of the core-dump file.

Directory to delete:

Shows list of directories available for deletion.

Repository scope:

Repository where core-dump files and log files are stored. The coredump files are located in the core repository, and the log files are located in the log repository. The default Repository scope is shared since both the core and log repositories are shared by all of the QFabric system devices.

Repository head:

Name of the top-level repository location.

Repository name:

Name of the repository: core or log.

Creating list of debug artifacts to be removed under:

Shows location of files available for deletion.

List of debug artifacts to be Shows list of files available for deletion. removed under:

Sample Output
request system storage cleanup dry-run
user@host> request system storage cleanup dry-run Currently rotating log files, please wait. This operation can take up to a minute.

761

List of files to delete:

Size Date

Name

11.4K Mar 8 15:00 /var/log/messages.1.gz

7245B Feb 5 15:00 /var/log/messages.3.gz

11.8K Feb 22 13:00 /var/log/messages.2.gz

3926B Mar 16 13:57 /var/log/messages.0.gz

3962B Feb 22 12:47 /var/log/sampled.1.gz

4146B Mar 8 12:20 /var/log/sampled.0.gz

4708B Dec 21 11:39 /var/log/sampled.2.gz

7068B Jan 16 18:00 /var/log/messages.4.gz

13.7K Dec 27 22:00 /var/log/messages.5.gz

890B Feb 22 17:22 /var/tmp/sampled.pkts

65.8M Oct 26 09:10 /var/sw/pkg/jinstall-7.4R1.7-export-signed.tgz

63.1M Oct 26 09:13 /var/sw/pkg/jbundle-7.4R1.7.tgz

request system storage cleanup

user@host> request system storage cleanup Currently rotating log files, please wait. This operation can take up to a minute.

List of files to delete:

Size Date

Name

11.4K Mar 8 15:00 /var/log/messages.1.gz

7245B Feb 5 15:00 /var/log/messages.3.gz

11.8K Feb 22 13:00 /var/log/messages.2.gz

3926B Mar 16 13:57 /var/log/messages.0.gz

11.6K Mar 8 15:00 /var/log/messages.5.gz

7254B Feb 5 15:00 /var/log/messages.6.gz

12.9K Feb 22 13:00 /var/log/messages.8.gz

3726B Mar 16 13:57 /var/log/messages.7.gz

3962B Feb 22 12:47 /var/log/sampled.1.gz

4146B Mar 8 12:20 /var/log/sampled.0.gz

4708B Dec 21 11:39 /var/log/sampled.2.gz

7068B Jan 16 18:00 /var/log/messages.4.gz

13.7K Dec 27 22:00 /var/log/messages.5.gz

890B Feb 22 17:22 /var/tmp/sampled.pkts

65.8M Oct 26 09:10 /var/sw/pkg/jinstall-7.4R1.7-export-signed.tgz

762
63.1M Oct 26 09:13 /var/sw/pkg/jbundle-7.4R1.7.tgz
Delete these files ? [yes,no] (yes)
request system storage cleanup (Junos OS Evolved)
user@host> request system storage cleanup Please check the list of files to be deleted using the dry-run option. Continue anyway without checking? [yes,no] (no) yes
------------------------------node: re0 ------------------------------Clearing all core files

Clearing all local host core files and files from /var/log/watchdog

Clearing node specific core files

Clearing FPC log files

Clearing logical-systems log files

Clearing journal logs

Clearing all /var/log/* files

Size 4.0K 4.0K 8.0K 4.0K 4.0K 4.0K 4.0K

Date Thu Nov 21 11:25 Thu Nov 21 11:27 Thu Nov 21 11:27 Thu Nov 21 11:24 Thu Nov 21 11:25 Thu Nov 21 11:23 Thu Nov 21 11:29

Name /var/log/__policy_names_rpdc__ /var/log/__policy_names_rpdn__ /var/log/alarm-mgmtd /var/log/boot_init.log /var/log/charonctl_trace.log /var/log/check_restore_recovery_bios.log /var/log/clksynced.log

763

80K 4.0K
0 4.0K 4.0K 4.0K 960K 2.9M
12K 8.0K 4.0K 4.0K
16K 0
12K 0
84K 0
4.0K 44K
4.0K 84K
1.4M 4.0K 4.0K 4.0K 4.0K
92K 16K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 20K 24K 4.0K 8.0K 4.2M 4.0K 4.0K

Thu Nov 21 11:27 Thu Nov 21 11:25 Thu Nov 21 11:24 Thu Nov 21 11:29 Thu Nov 21 11:25 Thu Nov 21 11:29 Thu Nov 21 11:48 Thu Nov 21 15:27 Thu Nov 21 11:29 Thu Nov 21 15:24 Thu Nov 21 11:25 Thu Nov 21 11:28 Thu Nov 21 11:29 Thu Nov 21 11:27 Thu Nov 21 11:29 Thu Nov 21 11:26 Thu Nov 21 15:27 Thu Nov 21 11:26 Thu Nov 21 11:25 Thu Nov 21 11:28 Thu Nov 21 11:25 Thu Nov 21 11:28 Thu Nov 21 11:48 Thu Nov 21 11:29 Thu Nov 21 11:29 Thu Nov 21 15:27 Thu Nov 21 11:29 Thu Nov 21 15:25 Thu Nov 21 11:28 Thu Nov 21 11:29 Thu Nov 21 11:24 Thu Nov 21 11:28 Thu Nov 21 11:29 Thu Nov 21 11:29 Thu Nov 21 11:28 Thu Nov 21 11:24 Thu Nov 21 11:23 Thu Nov 21 11:26 Thu Nov 21 15:24 Thu Nov 21 11:48 Thu Nov 21 11:25 Thu Nov 21 11:27

/var/log/configd-streamer.log /var/log/core_mgr.log /var/log/cscript.log /var/log/ddosd.log /var/log/disk_mgmt /var/log/eth_linkmon.log /var/log/evo-cda-zx.log /var/log/evo_dns_relay.log /var/log/evoinit.log /var/log/fibd-proxy.log /var/log/imgd.log /var/log/interactive-commands /var/log/kfirewall-agent.log /var/log/mcelog.log /var/log/mem_mgmt.log /var/log/mem_monitor.dat /var/log/messages /var/log/mgd-api /var/log/mgmt-ethd-helper.log /var/log/mib2d /var/log/mstr.log /var/log/packetio-cout.log /var/log/picd.log /var/log/platform_mon.log /var/log/ptp_fpga.log /var/log/security /var/log/set_mgmt_mac.log /var/log/sinet.log /var/log/snmpd /var/log/ss.log /var/log/ssh-key-utils.log /var/log/sshd_lua.log /var/log/sysconfig.log /var/log/sysstart.log /var/log/system-events /var/log/uswitch.log /var/log/uswitch.log.prev /var/log/validator_debug.log /var/log/wtmp /var/log/zookeeper--server-re0.log /var/log/zookeeper--server-re0.out /var/log/ztp.log

764
Clearing all JSON files in /var/log/objmon
Cleared traces for application all node all pid all
Clearing SI traces
Removing any ISO files in /data Current list of software versions installed Active boot device is primary : /dev/vda List of installed version(s) :
'-' running version '>' next boot version after upgrade/downgrade '<' rollback boot version - junos-evo-install-ptx-fixed-x86-64-20.1-201911201458.0-EVO - [2019-11-21 11:23:21] Current space available in /soft: 14752420 K and /data: 2788736 K
request system storage cleanup dry-run (Junos OS Evolved)
user@host> request system storage cleanup dry-run ------------------------------node: re0 ------------------------------List of all core files to be cleared:
List of local_host core files to be cleared:
List of core sub directory files to be cleared:

765
List of log files from FPCs to be cleared:
List of log files from logical systems to be cleared:
Clears all App logs, App traces, App SI traces and App core files from /var/log/*, /var/log/traces/*, /var/log/si_traces/* and /var/core/*
Clears all JSON files in /var/log/objmon/ during cleanup
List of ISO files from /data partition to be cleared:
Current list of software versions installed Removes older software versions - Minimum two versions would be left around
Active boot device is primary : /dev/vda List of installed version(s) :
'-' running version '>' next boot version after upgrade/downgrade '<' rollback boot version
- junos-evo-install-ptx-fixed-x86-64-20.1-201911201458.0-EVO - [2019-11-21 11:23:21]
request system storage cleanup force-deep (Junos OS Evolved)
user@host> request system storage cleanup force-deep Please check the list of files to be deleted using the dry-run option.
Continue anyway without checking? [yes,no] (no) yes
------------------------------node: re0 ------------------------------........ ========= Start cleanup now ========== === Start removing other logs, traces, core files === Clearing core files

766
Clearing FPC logs Clearing logical-systems logs === Clearing journal logs === Clearing log: /var/log/RE_journal.log Clearing log: /var/log/RE_journal_boot.log Clearing log: /var/log/alarm-mgmtd Clearing log: /var/log/appDemo_stdout Clearing log: /var/log/charonctl_trace.log Clearing log: /var/log/configd-streamer.log Clearing log: /var/log/core_mgr.log Clearing log: /var/log/cscript.log Clearing log: /var/log/eth_linkmon.log Clearing log: /var/log/evo-cda-zx.log Clearing log: /var/log/evoinit.log Clearing log: /var/log/fibd-proxy.log Clearing log: /var/log/i2ctrace.log Clearing log: /var/log/i2ctrace_spmb0.log Clearing log: /var/log/i2ctrace_spmb1.log Clearing log: /var/log/icmpd.log Clearing log: /var/log/ifinfo.log Clearing log: /var/log/imgd_svr.log Clearing log: /var/log/install Clearing log: /var/log/interactive-commands Clearing log: /var/log/jsd Clearing log: /var/log/lastlog Clearing log: /var/log/mcelog.log Clearing log: /var/log/messages Clearing log: /var/log/mgd-api Clearing log: /var/log/mgmt-ethd-helper.log Clearing log: /var/log/mib2d Clearing log: /var/log/na-grpcd Clearing log: /var/log/objmon_sync.json Clearing log: /var/log/packetio-cout.log Clearing log: /var/log/picd.log Clearing log: /var/log/platform_mon.log Clearing log: /var/log/policerd.log Clearing log: /var/log/postinstall.log Clearing log: /var/log/ptp_fpga.log Clearing log: /var/log/reboot_node.log Clearing log: /var/log/rollback.log Clearing log: /var/log/security Clearing log: /var/log/semctl.log Clearing log: /var/log/set_mgmt_mac.log

767
Clearing log: /var/log/shutdown_complete.log Clearing log: /var/log/sinet.log Clearing log: /var/log/smartd-attrSFSA200GM3AA4TO_C_HC_636_JUN-000060139624B1000020.log Clearing log: /var/log/smartd-attrSFSA200GM3AA4TO_C_HC_636_JUN-000060139624B1000022.log Clearing log: /var/log/snmpd Clearing log: /var/log/ss.log Clearing log: /var/log/ssh-key-utils.log Clearing log: /var/log/sshd_lua.log Clearing log: /var/log/sysconfig.log Clearing log: /var/log/sysman.conf Clearing log: /var/log/system-events Clearing log: /var/log/upgrade_master.log Clearing log: /var/log/uswitch.log Clearing log: /var/log/uswitch.log.prev Clearing log: /var/log/validator_debug.log Clearing log: /var/log/wtmp Clearing log: /var/log/zookeeper--server-re.log Clearing log: /var/log/zookeeper--server-re.out Clearing log: /var/log/ztp.log === Clearing all traces === === Clearing SI traces === === Removing other logs, traces, core files completed === === Started removing any ISO files in /data === Removing any ISO files in /data completed === Start Software versions cleanup === Removing older software versions except current and rollback === Software versions cleanup completed === ========= Cleanup done ========== Current space available in /soft: 12372572 K Current space available in /data: 2638752 K Cannot delete junos-evo-install-qfx-fixed-x86-64-18.3I20180906130134_mkamil - It is the rollback version Cannot delete junos-evo-install-qfx-fixed-x86-64-18.3-20180906.3 - It is the current version Removing version junos-evo-install-qfx-x86-64-16.2I20180516093649... Done.

768

request system storage cleanup director-group (QFabric Systems)

user@switch> request system storage cleanup director-group List of files to delete:

4.0K 4.0K 4.0K 4.0K 0 1.3M 4.0K 4.0K 9.6M 4.0K 248K 4.0K 4.0K 8.0K 0 4.0K 0 4.0K 4.0K 160K 38M 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 8.0K 4.0K 0 4.0K 0 0 4.0K 4.0K 8.0K

Size Date

Name

2011-11-07 05:16:29 /tmp/2064.sfcauth

2011-11-07 05:07:34 /tmp/30804.sfcauth

2011-11-07 04:13:41 /tmp/26792.sfcauth

2011-11-07 04:13:39 /tmp/26432.sfcauth

2011-11-07 07:45:40 /tmp/cluster_cleanup.log

2011-11-07 07:39:11 /tmp/cn_monitor.20111107-052401.log

2011-11-07 07:36:29 /tmp/clustat.28019.log

2011-11-07 07:36:29 /tmp/clustat_x.28019.log

2011-11-07 05:30:24 /tmp/sfc.2.log

2011-11-07 05:28:11 /tmp/mgd-init.1320672491.log

2011-11-07 05:19:24 /tmp/cn_monitor.20111107-045111.log

2011-11-07 05:17:18 /tmp/clustat.3401.log

2011-11-07 05:17:18 /tmp/clustat_x.3401.log

2011-11-07 04:58:25 /tmp/mgd-init.1320670633.log

2011-11-07 04:54:01 /tmp/mysql_db_install_5.1.37.log

2011-11-07 04:52:08 /tmp/cn_send.log

2011-11-07 04:52:00 /tmp/init_eth0.log

2011-11-07 04:49:35 /tmp/install_interfaces.sh.log

2011-11-07 04:48:15 /tmp/bootstrap.sh.log

2011-11-07 04:47:43 /tmp/bootstrap_cleanup.log

2011-11-07 04:42:42 /tmp/cn_monitor.20111104-110308.log

2011-11-07 04:38:47 /tmp/clustat.30913.log

2011-11-07 04:38:47 /tmp/clustat_x.30913.log

2011-11-07 04:38:03 /tmp/dcf_upgrade.sh.remove.log

2011-11-07 04:38:03 /tmp/peer_update.log

2011-11-07 04:38:02 /tmp/dcf_upgrade.log

2011-11-07 04:38:02 /tmp/perl_mark_upgrade.log

2011-11-07 04:13:42 /tmp/install_dcf_rpm.log

2011-11-07 04:13:06 /tmp/00_cleanup.sh.1320667986.log

2011-11-07 04:13:06 /tmp/ccif_patch_4410_4450.sh.1320667986.log

2011-11-07 04:13:06 /tmp/dcf-tools.sh.1320667986.log

2011-11-07 04:13:06 /tmp/initial.sh.1320667986.log

2011-11-07 04:13:06 /tmp/inventory.sh.1320667986.log

2011-11-07 04:13:06 /tmp/qf-db.sh.1320667986.log

2011-11-07 04:13:06 /tmp/sfc.sh.1320667986.log

2011-11-07 04:13:05 /tmp/jinstall-qfabric.log

769

8.0K 4.0K 8.0K 8.0K 4.0K 8.0K 4.0K 4.0K 8.0K

2011-11-04 11:10:24 2011-11-04 11:07:03 2011-11-04 10:55:07 2011-11-04 10:55:07 2011-11-04 10:55:07 2011-11-04 10:55:07 2011-11-04 10:54:09 2011-11-07 04:13:06 2011-11-04 10:55:07

/tmp/mgd-init.1320430192.log /tmp/mysql_dcf_db_install.log /tmp/ccif_patch_4410_4450.sh.1320429307.log /tmp/initial.sh.1320429307.log /tmp/inventory.sh.1320429307.log /tmp/sfc.sh.1320429307.log /tmp/ks-script-Ax0tz5.log /tmp//sfc.sh.1320667986.log /tmp//sfc.sh.1320429307.log

Directory to delete: 45M 2011-11-08 10:57:43 /tmp/sfc-captures

List of files to delete:

4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 4.0K 824K 4.0K 4.0K 4.0K 4.0K 92K 4.0K 4.0K

Size Date

Name

2011-11-08 05:47:47 /tmp/5713.sfcauth

2011-11-08 05:14:32 /tmp/14494.sfcauth

2011-11-08 05:11:47 /tmp/9978.sfcauth

2011-11-08 05:09:37 /tmp/6128.sfcauth

2011-11-08 05:04:28 /tmp/29703.sfcauth

2011-11-07 11:59:10 /tmp/7811.sfcauth

2011-11-07 11:36:08 /tmp/32415.sfcauth

2011-11-07 11:30:30 /tmp/22406.sfcauth

2011-11-07 11:24:37 /tmp/12131.sfcauth

2011-11-07 10:48:42 /tmp/12687.sfcauth

2011-11-07 09:27:20 /tmp/31082.sfcauth

2011-11-07 07:33:58 /tmp/14633.sfcauth

2011-11-07 05:08:25 /tmp/15447.sfcauth

2011-11-07 04:12:29 /tmp/26874.sfcauth

2011-11-07 04:12:27 /tmp/26713.sfcauth

2011-11-07 03:49:17 /tmp/17691.sfcauth

2011-11-05 01:32:23 /tmp/5716.sfcauth

2011-11-07 08:00:17 /tmp/sfcsnmpd.log

2011-11-07 07:57:50 /tmp/cluster_cleanup.log

2011-11-07 07:38:37 /tmp/cn_monitor.20111107-053643.log

2011-11-07 07:36:30 /tmp/clustat.18399.log

2011-11-07 07:36:30 /tmp/clustat_x.18399.log

2011-11-07 07:35:47 /tmp/command_lock.log

2011-11-07 05:39:54 /tmp/mgd-init.1320673194.log

2011-11-07 05:19:25 /tmp/cn_monitor.20111107-050412.log

2011-11-07 05:17:20 /tmp/clustat.30115.log

2011-11-07 05:17:20 /tmp/clustat_x.30115.log

770

8.0K 4.0K 0 4.0K 4.0K 160K 28M 4.0K 4.0K 4.0K 4.0K 12K 4.0K 4.0K 4.0K 4.0K 0 0 4.0K 4.0K 4.0K 0 8.0K 4.0K 8.0K 8.0K 8.0K 4.0K 8.0K 4.0K 4.0K 8.0K

2011-11-07 05:08:07 2011-11-07 05:04:57 2011-11-07 05:04:52 2011-11-07 05:02:38 2011-11-07 05:01:19 2011-11-07 05:00:47 2011-11-07 04:42:27 2011-11-07 04:38:49 2011-11-07 04:38:49 2011-11-07 04:38:05 2011-11-07 04:38:05 2011-11-07 04:38:05 2011-11-07 04:38:04 2011-11-07 04:38:04 2011-11-07 04:13:42 2011-11-07 04:11:57 2011-11-07 04:11:57 2011-11-07 04:11:57 2011-11-07 04:11:57 2011-11-07 04:11:57 2011-11-07 04:11:56 2011-11-07 04:11:56 2011-11-07 04:11:56 2011-11-07 04:11:33 2011-11-04 11:53:12 2011-11-04 11:06:17 2011-11-04 11:06:17 2011-11-04 11:06:17 2011-11-04 11:06:17 2011-11-04 11:05:19 2011-11-07 04:11:57 2011-11-04 11:06:17

/tmp/mgd-init.1320671241.log /tmp/cn_send.log /tmp/init_eth0.log /tmp/install_interfaces.sh.log /tmp/bootstrap.sh.log /tmp/bootstrap_cleanup.log /tmp/cn_monitor.20111104-112954.log /tmp/clustat.6780.log /tmp/clustat_x.6780.log /tmp/issue_event.log /tmp/peer_upgrade_reboot.log /tmp/primary_update.log /tmp/dcf_upgrade.sh.remove.log /tmp/peer_rexec_upgrade.log /tmp/peer_install_dcf_rpm.log /tmp/dcf-tools.sh.1320667917.log /tmp/initial.sh.1320667917.log /tmp/inventory.sh.1320667917.log /tmp/qf-db.sh.1320667917.log /tmp/sfc.sh.1320667917.log /tmp/00_cleanup.sh.1320667916.log /tmp/ccif_patch_4410_4450.sh.1320667916.log /tmp/jinstall-qfabric.log /tmp/dcf_upgrade.log /tmp/mgd-init.1320432782.log /tmp/ccif_patch_4410_4450.sh.1320429977.log /tmp/initial.sh.1320429977.log /tmp/inventory.sh.1320429977.log /tmp/sfc.sh.1320429977.log /tmp/ks-script-_tnWeb.log /tmp//sfc.sh.1320667917.log /tmp//sfc.sh.1320429977.log

Directory to delete: 49M 2011-11-08 10:45:20 /tmp/sfc-captures

request system storage cleanup infrastructure device-name (QFabric Systems)
user@switch> request system storage cleanup infrastructure FC re0: --------------------------------------------------------------------------

771

List of files to delete:

Size Date

Name

139B Nov 8 19:03 /var/log/default-log-messages.0.gz

5602B Nov 8 19:03 /var/log/messages.0.gz

28.4K Nov 8 10:15 /var/log/messages.1.gz

35.2K Nov 7 13:45 /var/log/messages.2.gz

207B Nov 7 16:02 /var/log/wtmp.0.gz

27B Nov 7 12:14 /var/log/wtmp.1.gz

184.4M Nov 7 12:16 /var/sw/pkg/jinstall-dc-re-11.3I20111104_1216_dc-builder-

domestic-signed.tgz

124.0K Nov 7 15:59 /var/tmp/gres-tp/env.dat

0B Nov 7 12:57 /var/tmp/gres-tp/lock

155B Nov 7 16:02 /var/tmp/krt_gencfg_filter.txt

0B Nov 7 12:35 /var/tmp/last_ccif_update

1217B Nov 7 12:15 /var/tmp/loader.conf.preinstall

184.4M Nov 6 07:11 /var/tmp/mchassis-install.tgz

10.8M Nov 7 12:16 /var/tmp/preinstall/bootstrap-install-11.3I20111104_1216_dc-

builder.tar

57.4K Nov 7 12:16 /var/tmp/preinstall/configs-11.3I20111104_1216_dc-

builder.tgz

259B Nov 7 12:16 /var/tmp/preinstall/install.conf

734.3K Nov 4 13:46 /var/tmp/preinstall/jboot-dc-re-11.3I20111104_1216_dc-

builder.tgz

177.8M Nov 7 12:16 /var/tmp/preinstall/jbundle-dc-re-11.3I20111104_1216_dc-

builder-domestic.tgz

124B Nov 7 12:15 /var/tmp/preinstall/metatags

1217B Nov 7 12:16 /var/tmp/preinstall_boot_loader.conf

0B Nov 7 16:02 /var/tmp/rtsdb/if-rtsdb

request system storage cleanup interconnect-device device-name (QFabric Systems)

user@switch> request system storage cleanup interconnect IC re1: --------------------------------------------------------------------------

List of files to delete:

Size Date

Name

11B Nov 7 15:55 /var/jail/tmp/alarmd.ts

772

128B Nov 9965B Nov 15.8K Nov 15.8K Nov 15.7K Nov 15.8K Nov 15.7K Nov 18.7K Nov 17.6K Nov 58.3K Nov 20.3K Nov
90B Nov 57B Nov 124.0K Nov
0B Nov 0B Nov 12.0K Nov 132.0K Nov 2688.0K Nov 2048.0K Nov 730B Nov 155B Nov 0B Nov

8 19:06 /var/log/default-log-messages.0.gz 8 19:06 /var/log/messages.0.gz 8 12:30 /var/log/messages.1.gz 8 11:00 /var/log/messages.2.gz 8 07:30 /var/log/messages.3.gz 8 04:00 /var/log/messages.4.gz 8 00:30 /var/log/messages.5.gz 7 21:00 /var/log/messages.6.gz 7 19:00 /var/log/messages.7.gz 7 16:00 /var/log/messages.8.gz 7 15:15 /var/log/messages.9.gz 7 15:41 /var/log/wtmp.0.gz 7 12:41 /var/log/wtmp.1.gz 7 15:42 /var/tmp/gres-tp/env.dat 7 12:40 /var/tmp/gres-tp/lock 7 12:41 /var/tmp/if-rtsdb/env.lck 7 15:41 /var/tmp/if-rtsdb/env.mem 7 15:55 /var/tmp/if-rtsdb/shm_usr1.mem 7 15:41 /var/tmp/if-rtsdb/shm_usr2.mem 7 15:41 /var/tmp/if-rtsdb/trace.mem 7 19:57 /var/tmp/juniper.conf+.gz 7 15:53 /var/tmp/krt_gencfg_filter.txt 7 15:41 /var/tmp/rtsdb/if-rtsdb

re0: --------------------------------------------------------------------------

List of files to delete:

Size Date

Name

11B Nov 7 15:55 /var/jail/tmp/alarmd.ts

121B Nov 8 19:06 /var/log/default-log-messages.0.gz

16.7K Nov 8 19:06 /var/log/messages.0.gz

22.2K Nov 8 17:45 /var/log/messages.1.gz

K Nov 8 17:00 /var/log/messages.2.gz

21.6K Nov 8 16:00 /var/log/messages.3.gz

17.9K Nov 8 14:30 /var/log/messages.4.gz

19.4K Nov 8 13:30 /var/log/messages.5.gz

18.2K Nov 8 12:30 /var/log/messages.6.gz

20.4K Nov 8 11:30 /var/log/messages.7.gz

21.4K Nov 8 10:15 /var/log/messages.8.gz

21.0K Nov 8 09:00 /var/log/messages.9.gz

19.9K Nov 8 08:13 /var/log/snmp-traps.0.gz

773

203B Nov 57B Nov
124.0K Nov 0B Nov 0B Nov
12.0K Nov 132.0K Nov 2688.0K Nov 2048.0K Nov
727B Nov 155B Nov
0B Nov

8 15:36 /var/log/wtmp.0.gz 7 12:41 /var/log/wtmp.1.gz 7 15:42 /var/tmp/gres-tp/env.dat 7 12:40 /var/tmp/gres-tp/lock 7 12:41 /var/tmp/if-rtsdb/env.lck 7 15:41 /var/tmp/if-rtsdb/env.mem 7 15:55 /var/tmp/if-rtsdb/shm_usr1.mem 7 15:41 /var/tmp/if-rtsdb/shm_usr2.mem 7 15:41 /var/tmp/if-rtsdb/trace.mem 7 15:54 /var/tmp/juniper.conf+.gz 7 15:55 /var/tmp/krt_gencfg_filter.txt 7 15:41 /var/tmp/rtsdb/if-rtsdb

request system storage cleanup node-group group-name (QFabric Systems)

user@switch> request system storage cleanup node-group NW-NG BBAK0372: --------------------------------------------------------------------------

List of files to delete:

Size Date

Name

126B Nov 8 19:07 /var/log/default-log-messages.0.gz

179B Nov 7 13:32 /var/log/install.0.gz

22.9K Nov 8 19:07 /var/log/messages.0.gz

26.5K Nov 8 17:30 /var/log/messages.1.gz

20.5K Nov 8 13:15 /var/log/messages.2.gz

33.2K Nov 7 17:45 /var/log/messages.3.gz

35.5K Nov 7 15:45 /var/log/messages.4.gz

339B Nov 8 17:10 /var/log/wtmp.0.gz

58B Nov 7 12:40 /var/log/wtmp.1.gz

124.0K Nov 8 17:08 /var/tmp/gres-tp/env.dat

0B Nov 7 12:39 /var/tmp/gres-tp/lock

0B Nov 7 12:59 /var/tmp/if-rtsdb/env.lck

12.0K Nov 8 17:09 /var/tmp/if-rtsdb/env.mem

2688.0K Nov 8 17:09 /var/tmp/if-rtsdb/shm_usr1.mem

132.0K Nov 8 17:09 /var/tmp/if-rtsdb/shm_usr2.mem

2048.0K Nov 8 17:09 /var/tmp/if-rtsdb/trace.mem

1082B Nov 8 17:09 /var/tmp/juniper.conf+.gz

155B Nov 7 17:39 /var/tmp/krt_gencfg_filter.txt

0B Nov 8 17:09 /var/tmp/rtsdb/if-rtsdb

774

EE3093: --------------------------------------------------------------------------

List of files to delete:

Size Date

Name

11B Nov 8 17:33 /var/jail/tmp/alarmd.ts

119B Nov 8 19:08 /var/log/default-log-messages.0.gz

180B Nov 7 17:41 /var/log/install.0.gz

178B Nov 7 13:32 /var/log/install.1.gz

2739B Nov 8 19:08 /var/log/messages.0.gz

29.8K Nov 8 18:45 /var/log/messages.1.gz

31.8K Nov 8 17:15 /var/log/messages.2.gz

20.6K Nov 8 16:00 /var/log/messages.3.gz

15.4K Nov 8 10:15 /var/log/messages.4.gz

15.4K Nov 8 02:15 /var/log/messages.5.gz

25.5K Nov 7 20:45 /var/log/messages.6.gz

48.0K Nov 7 17:45 /var/log/messages.7.gz

32.8K Nov 7 13:45 /var/log/messages.8.gz

684B Nov 8 17:02 /var/log/wtmp.0.gz

58B Nov 7 12:40 /var/log/wtmp.1.gz

124.0K Nov 7 17:34 /var/tmp/gres-tp/env.dat

0B Nov 7 12:40 /var/tmp/gres-tp/lock

0B Nov 7 12:59 /var/tmp/if-rtsdb/env.lck

12.0K Nov 7 17:39 /var/tmp/if-rtsdb/env.mem

2688.0K Nov 7 17:39 /var/tmp/if-rtsdb/shm_usr1.mem

132.0K Nov 7 17:40 /var/tmp/if-rtsdb/shm_usr2.mem

2048.0K Nov 7 17:39 /var/tmp/if-rtsdb/trace.mem

155B Nov 7 17:40 /var/tmp/krt_gencfg_filter.txt

0B Nov 7 17:39 /var/tmp/rtsdb/if-rtsdb

request system storage cleanup qfabric component device-name (QFabric Systems)

user@switch> request system storage cleanup qfabric component Test Repository type: regular Repository head: /pbstorage Creating list of debug artifacts to be removed under: /pbstorage/rdumps/Test Removing debug artifacts ... (press control C to abort) Removing /pbstorage/rdumps/Test/cosd.core.0.0.05162011123308.gz ... done Removing /pbstorage/rdumps/Test/cosd.core.1.0.05162011123614.gz ... done

775
Removing /pbstorage/rdumps/Test/cosd.core.2.0.05162011123920.gz ... done Removing /pbstorage/rdumps/Test/livekcore.05132011163930.gz ... done Removing /pbstorage/rdumps/Test/tnetd.core.0.1057.05162011124500.gz ... done Removing /pbstorage/rdumps/Test/vmcore.05132011120528.gz ... done Removing /pbstorage/rdumps/Test/vmcore.kz ... done Creating list of debug artifacts to be removed under: /pbstorage/rlogs/Test Removing debug artifacts ... (press control C to abort) Removing /pbstorage/rlogs/Test/kdumpinfo.05132011120528 ... done Removing /pbstorage/rlogs/Test/kernel.tarball.0.1039.05122011234415.tgz ... done Removing /pbstorage/rlogs/Test/kernel.tarball.1.1039.05132011175544.tgz ... done Removing /pbstorage/rlogs/Test/tnetd.tarball.0.1057.05162011175453.tgz ... done
request system storage cleanup qfabric component device-name repository core (QFabric Systems)
user@switch> request system storage cleanup qfabric component Test repository core Repository scope: shared Repository head: /pbdata/export Repository name: core Creating list of debug artifacts to be removed under: /pbdata/export/rdumps/Test NOTE: core repository under /pbdata/export/rdumps/Test empty
request system storage cleanup qfabric component all (QFabric Systems)
user@switch> request system storage cleanup qfabric component all Repository scope: shared Repository head: /pbdata/export Creating list of debug artifacts to be removed under: /pbdata/export/rdumps NOTE: core repository under /pbdata/export/rdumps/all empty Creating list of debug artifacts to be removed under: /pbdata/export/rlogs List of debug artifacts to clean up ... (press control C to abort) /pbdata/export/rlogs/73747cd8-0710-11e1-b6a4-00e081c5297e/ install-11072011125819.log /pbdata/export/rlogs/77116f18-0710-11e1-a2a0-00e081c5297e/ install-11072011125819.log /pbdata/export/rlogs/BBAK0372/install-11072011121538.log /pbdata/export/rlogs/BBAK0394/install-11072011121532.log /pbdata/export/rlogs/EE3093/install-11072011121536.log /pbdata/export/rlogs/WS001/YN5999/install-11072011121644.log

776
/pbdata/export/rlogs/WS001/YW3803/install-11072011122429.log /pbdata/export/rlogs/cd78871a-0710-11e1-878e-00e081c5297e/ install-11072011125932.log /pbdata/export/rlogs/d0afda1e-0710-11e1-a1d0-00e081c5297e/ install-11072011125930.log /pbdata/export/rlogs/d0afda1e-0710-11e1-a1d0-00e081c5297e/ install-11072011133211.log /pbdata/export/rlogs/d0afda1e-0710-11e1-a1d0-00e081c5297e/ install-11072011155302.log /pbdata/export/rlogs/d31ab7a6-0710-11e1-ad1b-00e081c5297e/ install-11072011125931.log /pbdata/export/rlogs/d4d0f254-0710-11e1-90c3-00e081c5297e/ install-11072011125932.log
Release Information
Command introduced in Junos OS Release 7.4. dry-run option introduced in Junos OS Release 7.6. satellite option introduced in Junos OS Release 14.2R3. no-confirm and (re0 |re1 | routing-engine (backup | both | local | master | other)) options introduced in Junos OS 17.3R1.
request system storage cleanup (SRX Series)
IN THIS SECTION Syntax | 777 Description | 777 Options | 777 Additional Information | 777 Required Privilege Level | 777 Output Fields | 778

777
Sample Output | 778 Release Information | 781

Syntax
request system storage cleanup <dry-run>

Description
Use this command to free storage space on the device by rotating log files and proposing a list of files for deletion.

Options

dry-run

(Optional) List files proposed for deletion (without deleting them).

Additional Information
If logging is configured and being used, the dry-run option rotates the log files. In that case, the output displays the message "Currently rotating log files, please wait." If no logging is currently under way, the output displays only a list of files to delete.
Required Privilege Level
maintenance

778

Output Fields

Table 29 on page 778 describes the output fields for the request system storage cleanup command. Output fields are listed in the approximate order in which they appear.
Table 29: request system storage cleanup Output Fields

Field Name

Field Description

List of files to delete:

Shows list of files available for deletion.

Size

Size of the core-dump file.

Date

Last core-dump file modification date and time.

Name

Name of the core-dump file.

Sample Output
request system storage cleanup dry-run

user@host> request system storage cleanup dry-run List of files to delete:

Size Date

Name

11B Jul 14 22:51 /var/jail/tmp/alarmd.ts

84.3K Jul 20 22:09 /var/log/chassisd.0.gz

83.0K Jul 20 04:35 /var/log/chassisd.1.gz

84.0K Jul 19 10:52 /var/log/chassisd.2.gz

90.4K Jul 18 17:16 /var/log/chassisd.3.gz

91.8K Jul 20 04:30 /var/log/hostlogs/auth.log.1.gz

93.1K Jul 17 05:45 /var/log/hostlogs/auth.log.2.gz

97.6K Jun 7 01:30 /var/log/hostlogs/auth.log.3.gz

92.0K Apr 25 15:15 /var/log/hostlogs/auth.log.4.gz

78.0K Jul 21 05:44 /var/log/hostlogs/daemon.log.1.gz

78.6K Jul 21 02:59 /var/log/hostlogs/daemon.log.2.gz

779
78.5K Jul 21 00:14 /var/log/hostlogs/daemon.log.3.gz 78.8K Jul 20 21:30 /var/log/hostlogs/daemon.log.4.gz 58.7K Jul 21 05:14 /var/log/hostlogs/debug.1.gz 58.5K Jul 21 00:59 /var/log/hostlogs/debug.2.gz 58.7K Jul 20 20:44 /var/log/hostlogs/debug.3.gz 58.7K Jul 20 16:29 /var/log/hostlogs/debug.4.gz 166.9K Jul 13 00:33 /var/log/hostlogs/kern.log.1.gz 166.5K Jun 1 02:32 /var/log/hostlogs/kern.log.2.gz 163.5K May 5 00:03 /var/log/hostlogs/kern.log.3.gz 152.3K Mar 2 23:23 /var/log/hostlogs/kern.log.4.gz 260.0K Apr 13 10:28 /var/log/hostlogs/lcmd.log.1.gz 257.3K Mar 7 00:38 /var/log/hostlogs/lcmd.log.2.gz 240.8K Feb 7 19:45 /var/log/hostlogs/lcmd.log.3.gz 241.1K Feb 7 14:00 /var/log/hostlogs/lcmd.log.4.gz 370.6K Jul 21 00:45 /var/log/hostlogs/syslog.1.gz 370.9K Jul 20 12:30 /var/log/hostlogs/syslog.2.gz 370.4K Jul 20 00:15 /var/log/hostlogs/syslog.3.gz 370.2K Jul 19 12:00 /var/log/hostlogs/syslog.4.gz 55.0K Jul 14 22:50 /var/log/hostlogs/vjunos0.log.1.gz 1467B Oct 28 2015 /var/log/install.0.gz 119.9K Jul 21 07:37 /var/log/messages.0.gz 147.4K May 27 01:30 /var/log/messages.1.gz 71.4K Apr 14 11:19 /var/log/messages.2.gz 90.7K Feb 28 14:15 /var/log/messages.3.gz 10.1K Jan 12 2016 /var/log/messages.4.gz 55.1K Jan 6 2016 /var/log/messages.5.gz 81.5K Dec 1 2015 /var/log/messages.6.gz 43.3K Oct 28 2015 /var/log/messages.7.gz 54.8K Oct 20 2015 /var/log/messages.8.gz 35.8K Oct 19 2015 /var/log/messages.9.gz 12.4K Jul 21 07:37 /var/log/security.0.gz 59.4K Jul 19 01:30 /var/log/security.1.gz 51.8K Apr 25 10:00 /var/log/security.2.gz 43.6K Apr 14 11:19 /var/log/security.3.gz 52.7K Apr 5 02:15 /var/log/security.4.gz 54.4K Mar 25 17:15 /var/log/security.5.gz 51.9K Mar 16 05:15 /var/log/security.6.gz 52.0K Mar 5 02:15 /var/log/security.7.gz 53.4K Feb 22 22:15 /var/log/security.8.gz 55.6K Feb 13 13:00 /var/log/security.9.gz 4063B Jul 14 22:51 /var/tmp/cleanup-pkgs.log
0B Jul 14 22:51 /var/tmp/eedebug_bin_file 50.9K Feb 8 20:33 /var/tmp/event_tags.php

780

34B Jul 14 22:51 /var/tmp/gksdchk.log 124.0K Apr 26 06:12 /var/tmp/gres-tp/env.dat
0B Oct 9 2015 /var/tmp/gres-tp/lock 4B Jul 14 22:52 /var/tmp/idp_license_info 46B Jul 14 22:51 /var/tmp/kmdchk.log 57B Jul 14 22:51 /var/tmp/krt_rpf_filter.txt 30B Jul 14 22:53 /var/tmp/policy_status 0B Jul 14 22:51 /var/tmp/rtsdb/if-rtsdb 349B Jul 14 22:51 /var/tmp/sd-upgrade/debug_log 0B Oct 9 2015 /var/tmp/spu_kmd_init 53B Feb 7 23:11 /var/tmp/vjunos-install.log 0B Jul 14 22:51 /var/tmp/vpn_tunnel_orig.id

request system storage cleanup

user@host> request system storage cleanup List of files to delete:

Size Date

Name

11B Oct 28 23:40 /var/jail/tmp/alarmd.ts

92.4K Jan 11 17:12 /var/log/chassisd.0.gz

92.4K Jan 11 06:06 /var/log/chassisd.1.gz

92.5K Jan 10 19:00 /var/log/chassisd.2.gz

92.5K Jan 10 07:53 /var/log/chassisd.3.gz

92.2K Jan 10 15:00 /var/log/hostlogs/auth.log.1.gz

92.2K Jan 1 18:45 /var/log/hostlogs/auth.log.2.gz

92.1K Jan 4 17:30 /var/log/hostlogs/auth.log.3.gz

92.2K Jan 1 18:45 /var/log/hostlogs/auth.log.4.gz

79.0K Jan 12 01:59 /var/log/hostlogs/daemon.log.1.gz

78.8K Jan 11 23:15 /var/log/hostlogs/daemon.log.2.gz

78.7K Jan 11 20:30 /var/log/hostlogs/daemon.log.3.gz

79.1K Jan 11 17:44 /var/log/hostlogs/daemon.log.4.gz

59.1K Jan 11 21:59 /var/log/hostlogs/debug.1.gz

59.2K Jan 11 17:44 /var/log/hostlogs/debug.2.gz

59.2K Jan 11 13:29 /var/log/hostlogs/debug.3.gz

59.3K Jan 11 09:14 /var/log/hostlogs/debug.4.gz

186.6K Oct 20 16:31 /var/log/hostlogs/kern.log.1.gz

238.3K Jan 11 23:15 /var/log/hostlogs/lcmd.log.1.gz

238.4K Jan 11 17:30 /var/log/hostlogs/lcmd.log.2.gz

238.6K Jan 11 11:45 /var/log/hostlogs/lcmd.log.3.gz

238.5K Jan 11 06:00 /var/log/hostlogs/lcmd.log.4.gz

781
372.5K Jan 11 17:00 /var/log/hostlogs/syslog.1.gz 372.5K Jan 11 04:45 /var/log/hostlogs/syslog.2.gz 371.9K Jan 10 16:30 /var/log/hostlogs/syslog.3.gz 372.7K Jan 10 04:15 /var/log/hostlogs/syslog.4.gz
10.1K Jan 12 02:03 /var/log/messages.0.gz 55.1K Jan 6 21:25 /var/log/messages.1.gz 81.5K Dec 1 21:30 /var/log/messages.2.gz
Delete these files ? [yes,no] (no)
Release Information
Command introduced in Junos OS Release 9.2.
RELATED DOCUMENTATION Cleaning Up Files with the CLI
request system zeroize
IN THIS SECTION Syntax | 782 Syntax | 782 Description | 782 Options | 783 Required Privilege Level | 784 Sample Output | 784 Release Information | 785

782
Syntax
request system zeroize <media> <local>
Syntax
Description
Use this command to remove all configuration information on the Routing Engines and reset all key values on the device where you run the command. · If the device has dual Routing Engines, the command is broadcast to all Routing Engines on the
device. · In a Virtual Chassis or Virtual Chassis Fabric (VCF) composed of EX Series switches (except EX8200
Virtual Chassis) or QFX Series switches, this command operates only on the member switch where you run the command, even if that switch is in the primary Routing Engine role. The command is not forwarded to the backup Routing Engine member or to member switches in the line-card role. To apply this command to more than one member of an EX Series or QFX Series Virtual Chassis or VCF, we recommend you remove and disconnect each of those members from the Virtual Chassis or VCF, and then run the command on each isolated switch individually. This command removes all data files, including customized configuration and log files, by unlinking the files from their directories. The command removes all user-created files from the system, including all plain-text passwords, secrets, and private keys for SSH, local encryption, local authentication, IPsec, RADIUS, TACACS+, and SNMP. This command reboots the device and sets it to the factory default configuration. After the reboot, you cannot access the device through the management Ethernet interface. Log in through the console as root and start the Junos OS CLI by typing cli at the prompt. If the configuration contains the commit synchronize statement at the [edit system] hierarchy level, and you issue a commit in the primary Routing Engine, the primary configuration is automatically synchronized with the backup. If the backup Routing Engine is down when you issue the commit, the Junos OS displays a warning and commits the candidate configuration in the primary Routing Engine.

783
When the backup Routing Engine comes up, its configuration will automatically be synchronized with the primary. A newly inserted backup Routing Engine or a Routing Engine that comes up after running the request system zeroize command also automatically synchronizes its configuration with the primary Routing Engine configuration.
Starting with Junos OS Release 15.1F3, the request system zeroize command removes all configuration information on the guest OS for the PTX5000 router with RE-DUO-C2600-16G, and MX240, MX480, and MX960 with RE-S-1800X4-32G-S.
Starting with Junos OS Release 15.1F5, the request system zeroize command removes all configuration information on the guest OS for the MX2010 and MX2020 with REMX2K-1800-32G-S.
On these routers, in order to remove all configuration information on both guest OS and host OS, use the request vmhost zeroize command.
To completely erase user-created data so that it is unrecoverable, use the media option.

Options

media

(Optional) In addition to removing all configuration and log files, causes memory and the media to be scrubbed, removing all traces of any user-created files. Every storage device attached to the system is scrubbed, including disks, flash drives, removable USBs, and so on. The duration of the scrubbing process is dependent on the size of the media being erased. As a result, the request system zeroize media operation can take considerably more time than the request system zeroize operation. However, the critical security parameters are all removed at the beginning of the process.

On QFX Series platforms running Junos OS Release 14.1X53 or earlier, the media option is not available. On QFX Series platforms running releases later than Junos OS Release 14.1X53 that do not have the upgraded FreeBSD kernel (10+), the media option is available, but if you use it, the system will issue a warning that the media option is not supported and will continue with the zeroize operation. On platforms that are not QFX Series platforms, the media option is not available in Junos OS Release 17.2 or later with Junos with upgraded FreeBSD.

local (Optional) Remove all the configuration information and restore all the key values on the active Routing Engine.

Specifying this option has no effect on switches in a Virtual Chassis or VCF composed of EX Series switches (except EX8200 Virtual Chassis) or QFX switches, because in these configurations, the request system zeroize command only operates locally by default.

784
Required Privilege Level
maintenance
Sample Output
request system zeroize
user@host> request system zeroize warning: System will be rebooted and may not boot without configuration Erase all data, including configuration and log files? [yes,no] (no) yes
0 1 1 0 0 0 done
syncing disks... All buffers synced. Uptime: 5d19h20m26s recorded reboot as normal shutdown Rebooting...
U-Boot 1.1.6 (Mar 11 2011 - 04:39:06)
Board: EX4200-24T 2.11 EPLD: Version 6.0 (0x85) DRAM: Initializing (1024 MB) FLASH: 8 MB
Firmware Version: --- 01.00.00 --USB: scanning bus for devices... 2 USB Device(s) found
scanning bus for storage devices... 1 Storage Device(s) found
ELF file is 32 bit Consoles: U-Boot console
FreeBSD/PowerPC U-Boot bootstrap loader, Revision 2.4 (user@device.example.net, Fri Mar 11 03:03:36 UTC 2011) Memory: 1024MB bootsequencing is enabled bootsuccess is set

785
new boot device = disk0s1: Loading /boot/defaults/loader.conf /kernel data=0x915c84+0xa1260 syms=[0x4+0x7cbd0+0x4+0xb1c19]
Hit [Enter] to boot immediately, or space bar for command prompt. Booting [/kernel]... Kernel entry at 0x800000e0 ... GDB: no debug ports present KDB: debugger backends: ddb KDB: current backend: ddb Copyright (c) 1996-2011, Juniper Networks, Inc. All rights reserved. Copyright (c) 1992-2006 The FreeBSD Project. Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994
The Regents of the University of California. All rights reserved. JUNOS 11.1R1.8 #0: 2011-03-09 20:14:25 UTC
user@device.example.net:/volume/build/junos/11.1/release/11.1R1.8/objpowerpc/bsd/kernels/
JUNIPER-EX/kernel Timecounter "decrementer" frequency 50000000 Hz quality 0 cpu0: Freescale e500v2 core revision 2.2 cpu0: HID0 80004080 ...
Release Information
Command introduced before Junos OS Release 9.0. Option media added in Junos OS Release 11.4 for EX Series switches. Option local added in Junos OS Release 14.1.
RELATED DOCUMENTATION request system snapshot | 655 Reverting to the Default Factory Configuration for the EX Series Switch Reverting to the Rescue Configuration for the EX Series Switch Reverting to the Default Factory Configuration

786
Reverting to the Rescue Configuration Reverting to the Default Factory Configuration by Using the request system zeroize Command
rollback
IN THIS SECTION Syntax | 786 Description | 786 Options | 787 Required Privilege Level | 787 Release Information | 787
Syntax
rollback <number | rescue | revision revision-string>
Description
Return to a previously committed configuration. The software saves the last 50 committed configurations, including the rollback number, date, time, and name of the user who issued the commit configuration command. The currently operational configuration is stored in the file juniper.conf, and the last three committed configurations are stored in the files juniper.conf.1, juniper.conf.2, and juniper.conf.3. These four files are located in the directory /config, which is on the router's flash drive. The remaining 46 previous committed configurations, the files juniper.conf.4 through juniper.conf.49, are stored in the directory /var/db/config, which is on the router's hard disk.

787
During rollback, the configuration you specify is loaded from the associated file. Only objects in the rollback configuration that differ from the previously loaded configuration are marked as changed (equivalent to load update).

Options

none

(Optional) Return to the most recently saved configuration.

number

(Optional) Configuration to return to. The range of values is from 0 through 49. The most recently saved configuration is number 0, and the oldest saved configuration is number 49. The default is 0.

rescue

(Optional) Return to the rescue configuration.

revision revision-string

(Option) Use a configuration revision identifier to rollback to a specific configuration. Use the show system commit include-configuration-revision command to view the configuration revision identifier for each revision.

Required Privilege Level
rollback--To roll back to configurations other than the one most recently committed.
Release Information
Command introduced before Junos OS Release 7.4. Option revision introduced in Junos OS Release 20.4R1 and Junos OS Evolved Release 20.4R1.
RELATED DOCUMENTATION Returning to a Previously Committed Configuration Creating and Returning to a Rescue Configuration

788
show app-engine crash
IN THIS SECTION Syntax | 788 Description | 788 Options | 788 Additional Information | 789 Required Privilege Level | 789 Output Fields | 789 Sample Output | 790 Release Information | 790
Syntax
show app-engine crash <compute-cluster compute-cluster-name> <compute-cluster compute-cluster-name compute-node compute-node-name>
Description
Displays information regarding crashes on the Junos V App Engine or host OS. The command displays the list of files present in the /var/crash/ directory, as well as some core files located in the /var/tmp/ directory.
Options
· compute-cluster compute-cluster-name compute-node compute-node-name--Name of the compute cluster and compute node. On QFX switches with a host OS, the default compute cluster

789
and compute node names are default-cluster and default-node, and the command applies to the host OS by default.

Additional Information
In the operational mode of the CLI when you type ? for a name, for example a compute-node name, you would expect to get a list of available compute nodes plus the option to type in a name not listed. This is the auto-complete feature in the CLI. However, in JunosV App Engine, ,if you specify compute cluster and compute node in the operational command, the auto-complete works only if the compute cluster is put before the compute node.
For commands with an optional compute-cluster compute-cluster-name option, if that option is omitted, the command will be executed on all compute nodes of all compute clusters. For commands with an optional compute-node compute-node-name option, if that option is omitted, the command will be executed on all compute nodes of the specified compute cluster.

Required Privilege Level
view

Output Fields

For a description of the output fields, see Table 30 on page 789. Output fields are listed in the approximate order in which they appear.
Table 30: show app-engine crash Output Fields

Field Name

Field Description

Compute Cluster

Name of compute cluster.

Compute Node

Name of compute node.

Crash Info

List of core files.

790
Sample Output
show app-engine crash (QFX5100 Switches)
user@host> show app-engine crash Compute cluster: default-cluster
Compute node: default-node Crash Info ========== total 0
Release Information
Command introduced in Junos OS Release 13.2X51-D15.
RELATED DOCUMENTATION request app-engine file-copy (crash | log) from-jhost to-vjunos | 597
show app-engine logs
IN THIS SECTION Syntax | 791 Description | 791 Options | 791 Additional Information | 791 Required Privilege Level | 792

791
Output Fields | 792 Sample Output | 792 Release Information | 793
Syntax
show app-engine logs <compute-cluster compute-cluster-name> <compute-cluster compute-cluster-name compute-node compute-node-name>
Description
Displays log files regarding the state of the specified Guest VM or host OS, located in the /var/log/ directory.
Options
· compute-cluster compute-cluster-name compute-node compute-node-name--Name of the compute cluster and name of the compute node. On QFX switches with a host OS, the default compute cluster and compute node names are default-cluster and default-node, and the command applies to the host OS by default.
Additional Information
In the operational mode of the CLI when you type ? for a name, for example a compute-node name, you would expect to get a list of available compute nodes plus the option to type in a name not listed. This is the auto-complete feature in the CLI. However, in JunosV App Engine, if you specify compute cluster and compute node in the operational command, the auto-complete works only if the compute cluster is put before the compute node.

792
For commands with an optional compute-cluster compute-cluster-name option, if that option is omitted, the command will be executed on all compute nodes of all compute clusters. For commands with an optional compute-node compute-node-name option, if that option is omitted, the command will be executed on all compute nodes of the specified compute cluster.

Required Privilege Level
view

Output Fields

For a description of the output fields, see Table 31 on page 792. Output fields are listed in the approximate order in which they appear.
Table 31: show app-engine logs Output Fields

Field Name

Field Description

Compute Cluster

Name of compute cluster.

Compute Node

Name of compute node.

Logs Info

List of log files.

Sample Output
show app-engine logs (QFX5100 Switches)
user@host> show app-engine logs Compute cluster: default-cluster
Compute node: default-node

793

Logs Info

=========

total 1012

drwxr-xr-x 2 root root 4096 Feb 2 13:53 audit

-rw-r--r-- 1 root root

0 Feb 2 13:59 named.log

-rw-r--r-- 1 root root

0 Feb 2 15:30 btmp

drwxr-xr-x 2 root root 4096 Feb 2 17:11 ntpstats

-rw------- 1 root root

0 Feb 2 17:27 tallylog

drwxr-xr-x 2 root root 4096 Feb 7 10:10 stap-server

-rw------- 1 root root

0 Feb 7 10:16 spooler

-rw------- 1 root root

0 Feb 7 10:16 maillog

-rw------- 1 root root

0 Feb 7 10:16 boot.log

drwxr-xr-x 5 root root 4096 Feb 7 10:16 libvirt

drwxr-x--- 2 root root 4096 Feb 7 10:16 watchdog

-rw-r--r-- 1 root root 41693 Feb 10 04:27 dmesg.old

drwxr-xr-x 2 root root 4096 Feb 10 04:30 sa

-rw-r--r-- 1 root root 41693 Feb 10 09:35 dmesg

-rw-rw-r-- 1 root root 1193 Feb 10 09:47 vjunos_install_log

-rw-rw-r-- 1 root utmp 141312 Feb 10 10:08 wtmp

-rw------- 1 root root 25514 Feb 10 10:08 secure

-rw-r--r-- 1 root root 292 Feb 10 10:08 lastlog

-rw------- 1 root root 338593 Feb 10 10:17

cron

-rw-r--r-- 1 root root 383229 Feb 10 10:17 messages

Release Information
Command introduced in Junos OS Release 13.2X51-D15.
RELATED DOCUMENTATION request app-engine file-copy (crash | log) from-jhost to-vjunos | 597

794
show chassis usb storage
IN THIS SECTION Syntax | 794 Description | 794 Required Privilege Level | 794 Sample Output | 795 Release Information | 795
Syntax
show chassis usb storage
Description
This command displays the current status of any USB storage device and whether the USB ports are enabled or disabled.
Required Privilege Level
view

795

Sample Output
show chassis hardware detail

user@host> show chassis hardware detail

Hardware inventory:

Item

Version Part number Serial number

Description

Chassis

BV4911AA0005

SRX240H2-POE

Routing Engine REV 01 750-043613 AAEC1923

RE-SRX240H2-POE

usb0 (addr 1) DWC OTG root hub 0 vendor 0x0000

uhub0

usb0 (addr 2) product 0x005a 90

vendor 0x0409

uhub1

usb0 (addr 3) ST72682 High Speed Mode 64218 STMicroelectronics umass0

usb0 (addr 4) Mass Storage Device 4096 JetFlash

umass1

FPC 0

FPC

PIC 0

16x GE Base PIC

Power Supply 0

show chassis usb storage

user@host> show chassis usb storage USB Disabled

Release Information
Command introduced in Junos OS Release 11.4 R2.
RELATED DOCUMENTATION Installing Junos OS on SRX Series Devices Using a USB Flash Drive | 250

796
show system applications
IN THIS SECTION Syntax | 796 Description | 796 Options | 797 Required Privilege Level | 797 Output Fields | 797 Sample Output | 801 Release Information | 807
Syntax
show system applications <app app-name> <brief> <detail> <node node-name>
Description
This command displays applications summary information in one of the following forms: · Shows all applications summary information for all nodes. · Shows the applications summary information for a specific application. · Shows the applications summary information for a specific node.

797

Options

app app-name

(Optional) Specify application name for which you want to display applications summary information.

brief

(Optional) Display brief output. This is the default format of display.

detail

(Optional) Display detailed output.

node node-name (Optional) Specify node name for which you want to display applications summary information.

Required Privilege Level
view
Output Fields
For a description of the output fields, see Table 32 on page 798. Output fields are listed in the approximate order in which they appear.

798

Table 32: show system applications Output Fields

Field Name

Description

Level

Applications Information

Application Node App State
App Weight
App Zookeeper Session

Name of the application.

all levels

Name of the node the application is running on.

State of the application: online, offline, failed, or active.

A relative weight for multiple instances of the app across multiple nodes. The app instance with the higher wright is providing more functionality.

Zeekeeper session ID.

Object Producer details

Producer ID Epoch ID

Production Topic
Producer State

Identifies which production set the object is part of.

all levels

A number that identifies the current process that owns a production set. There can only be one owning process (active producer) that owns a production set at one time. The current owning process has an Epoch ID that is larger than any previous producer.

Hierarchical string that represents the production set.

active or standby:
· active indicates the application has production rights to modify the state in the production set.
· standy means that the application is waiting to get the production right for the production set.

Description

A short description of the application, it also lists the systemd service file used for the application.

detail

799

Table 32: show system applications Output Fields (Continued)

Field Name

Description

Level

Loaded

A systemd state that indicates if the application is loaded in the system detail or not.

Run State from OS

A systemd state that indicates if the application is active or not.

detail

Main PID

Process identifier (PID) of the application.

detail

Command

Command line to launch the application.

detail

ID

Name of the application.

detail

Meta

Meta data for the application includes the following fields:

detail

Bin path

Path to application execution.

Log file

Where logs go.

Working Dir Working directory.

Production Set Global or local production set. Values might be shared or local.

800

Table 32: show system applications Output Fields (Continued)

Field Name

Description

Level

Resource

Resource data for the application includes the following fields:

detail

all nodes

Is the application run on all nodes, true or false.

Max instances How many instances of the application are there.

Max instances per node

How many instances of the application per node are there.

Run on startup Is the appliction launched at bootup, true or false.

Node attributes

Typical node attributes are RE, FPC, MasterRE. You can see the node attributes by using the show system node-attributes command.

Node attribute match

What is the node attribute required to launch this application on a node? For example, if this field has the output re, Service file: lfmd, it indicates that the process lfmd will be launched on a node that has the attribute RE.

Failure

Failure data for the application includes the following fields:

Alarm color Which alarm to be raised on failure, or none.

Alarm ID

The alarm ID.

Restart

Whether to restart the application, true or false.

detail

Upgrade

Upgrade parallely Upgrade restart node Upgrade style

Options are true or false. Options are true or false. Option is stop-start.

detail

801

Table 32: show system applications Output Fields (Continued)

Field Name

Description

Level

App-Exit

App-Exit data for the application includes the following fields:

detail

Restart Supported True/false. When the apllication exits, should the application be restarted.

Restart Node

True/false. When the apllication exits, should the node be rebooted.

Mark node spare When an application exits, should the node be marked spare.

Sample Output
show system applications

user@host> show system applications

Applications Information:

Application

: bcmd_evo

Node

: fpc0

App State

: offline

Object Producer details

Producer ID

: 0

Epoch ID

: 0

Applications Information:

Application

: ccdpfe

Node

: fpc0

App State

: online

Object Producer details

Producer ID

: 576

Epoch ID

: 65

Production Topic

: /Root/fpc0/ccdpfe/100143551468101228

Producer State

: active

802

Applications Information:

Application

: cmdd

Node

: fpc0

App State

: online

Object Producer details

Producer ID

: 570

Epoch ID

: 66

Production Topic

: /Root/fpc0/cmdd/1099227235289688912

Producer State

: active

...

Applications Information:

Application

: alarm-mgmtd

Node

: re0

App State

: online

Object Producer details

Producer ID

: 26

Epoch ID

: 1

Production Topic

: /Root/alarm-mgmtd/2988563069668674039

Producer State

: active

Applications Information:

Application

: alarmd

Node

: re0

App State

: online

Object Producer details

Producer ID

: 377

Epoch ID

: 30

Production Topic

: /Root/alarmd/6512784671716237713

Producer State

: active

Applications Information:

Application

: arpd

Node

: re0

App State

: online

Object Producer details

Producer ID

: 396

Epoch ID

: 41

Production Topic

: /Root/arpd/14284058728950342139

Producer State

: active

...

803

Applications Information:

Application

: alarm-mgmtd

Node

: re1

App State

: online

Object Producer details

Producer ID

: 26

Epoch ID

: 0

Production Topic

: /Root/alarm-mgmtd/2988563069668674039

Producer State

: standby

Applications Information:

Application

: bcmd_evo

Node

: re1

App State

: offline

Object Producer details

Producer ID

: 0

Epoch ID

: 0

Applications Information:

Application

: charonctl

Node

: re1

App State

: online

Object Producer details

Producer ID

: 25

Epoch ID

: 4

Production Topic

: /Root/re1/charonctl/10854553120394604032

Producer State

: active

...

show system applications app application-name node node-name

user@host> show system applications app alarm-mgmtd node re1

Applications Information:

Application

: alarm-mgmtd

Node

: re1

App State

: online

Object Producer details

Producer ID

: 26

Epoch ID

: 0

804

Production Topic Producer State

: /Root/alarm-mgmtd/2988563069668674039 : standby

show system applications node node-name detail
user@host> show system applications app cmdd detail

Applications Information:

Application

:

cmdd

Node

:

re0

App State ready

: online

App Weight

:

1

App Zookeeper Session : 1000000934d000d

Object Producer details

Producer ID

:

50331736

Epoch ID

:

47

Production Topic 3158206796014561683

: /Root/re0/cmdd/

Producer State

:

active

805

Description Daemon"

: cmdd.service - "Command

Loaded

: loaded (/etc/systemd/system/cmdd.service;static;vendor

preset:enabled)

Run State from OS

: active (running) (Result: success) since Mon

2018-10-29 05:02:24 PDT

Main PID

:

5814

Command shared-objects-mode 3 App Config Info

: /usr/sbin/cmdd --app-name cmdd -I object_select --

ID

:

cmdd

Meta
Bin path cmdd
Log file Working Dir sbin
Production Set local
Sysman Managed true
Type Evo true

: /usr/sbin/ : /var/log : /usr/ : : :

Resource

All nodes

:

true

806

Max instances

:

1

Max instances per node: 1

App Suite

:

default,diags_default

Run on startup

Node

attributes

:

: true

(Node attribute match : *, Service file : cmdd)

Failure

Alarm color

:

red

Restart Node

:

false

Mark node spare

:

false

Upgrade
Upgrade parallely true
Upgrade restart node false
Upgrade style start
AppExit

: : : stop-

807

Restart Supported true
Restart Node Mark node spare false

:
: false :

[edit]

user@host#

Applications Information:

Upgrade

Prepare to upgrade notify : false

Unprepare to upgrade notify : false

Node upgrade done notify : false

System upgrade done notify : false

Upgrade abort capable

: false

Weight

: 1

App-Exit

Restart Supported

: false

Restart Node

: false

Mark node spare

: false

Release Information
Command introduced in Junos OS Evolved Release 18.3R1.
RELATED DOCUMENTATION request node halt (Junos OS Evolved) | 0 request node (offline | online) | 599 request node power-off (Junos OS Evolved) | 0 request node power-on (Junos OS Evolved) | 0 request node reboot (re0 | re1) | 601

808
show system autoinstallation status
IN THIS SECTION Syntax | 808 Description | 808 Options | 808 Required Privilege Level | 809 Output Fields | 809 Sample Output | 810 Release Information | 810
Syntax
show system autoinstallation status
Description
This command displays autoinstallation status information (ACX Series routers, and EX Series switches only).
Options
This command has no options.

809
Required Privilege Level
view

Output Fields

Table 33 on page 809 describes the output fields for the show system autoinstallation status command. Output fields are listed in the approximate order in which they appear.
Table 33: show system autoinstallation status Output Fields

Field Name

Field Description

Autoinstallation status

Display autoinstallation status information:
· Last committed file--File last committed for autoinstallation configuration.
· Configuration server of last committed file--IP address or URL of the server configured to retrieve configuration information for the last committed configuration file.
· Interface--Interface configured for autoinstallation.
· Name--Name of the interface.

· State--Interface state.
· Address acquisition--Display IP address acquired and protocol used for acquisition upon startup. · Protocol--Protocol used for acquisition: BOOTP/DHCP or RARP.
· Acquired address--IP address acquired from the DHCP server.

810
Sample Output
show system autoinstallation status
user@host> show system autoinstallation status Autoinstallation status: Master state: Active Last committed file: None Configuration server of last committed file: 10.0.0.0 Interface:
Name: ge-0/0/1 State: None Address acquisition:
Protocol: DHCP Client Acquired address: None Protocol: RARP Client Acquired address: None
Release Information
Command introduced before Junos OS Release 7.4. Command supported in Junos OS Release 12.2 for ACX Series Universal Metro Routers.
RELATED DOCUMENTATION ACX Series Autoinstallation Overview | 506 Before You Begin Autoinstallation on an ACX Series Universal Metro Router | 508 Autoinstallation Configuration of ACX Series Universal Metro Routers | 509 USB Autoinstallation on ACX Series Routers | 511 Verifying Autoinstallation on ACX Series Universal Metro Routers | 510 autoinstallation

811
show system autorecovery state
IN THIS SECTION Syntax | 811 Description | 811 Required Privilege Level | 811 Output Fields | 811 Sample Output | 812 Release Information | 813
Syntax
show system autorecovery state
Description
This command perform checks and show status of all autorecovered items.
Required Privilege Level
view
Output Fields
Table 34 on page 812 lists the output fields for the show system autorecovery state command. Output fields are listed in the approximate order in which they appear.

812

Table 34: show system autorecovery state Output Fields

Field Name

Field Description

File

The name of the file on which autorecovery checks are performed.

Slice

The disk partition on which autorecovery checks are performed.

Recovery Information

Indicates whether autorecovery information for the file or slice has been saved.

Integrity Check

Displays the status of the file's integrity check (passed or failed).

Action / Status

Displays the status of the item, or the action required to be taken for that item.

Sample Output
show system autorecovery state

user@host> show system autorecovery state

Configuration: File rescue.conf.gz Licenses: File JUNOS282736.lic JUNOS282737.lic BSD Labels: Slice s1 s2 s3 s4

Recovery Information Saved
Recovery Information Saved Not Saved
Recovery Information Saved Saved Saved Saved

Integrity Check Passed
Integrity Check Passed Not checked
Integrity Check Passed Passed Passed Passed

Action / Status None
Action / Status None Requires save
Action / Status None None None None

813
Release Information
Command introduced in Junos OS Release 15.1X49-D35.
RELATED DOCUMENTATION request system autorecovery state | 605
show system boot-messages
IN THIS SECTION Syntax | 813 Syntax (EX Series Switches) | 814 Syntax (TX Matrix Router) | 814 Syntax (TX Matrix Plus Router) | 814 Syntax (MX Series Router) | 814 Syntax (QFX Series) | 815 Description | 815 Options | 815 Additional Information | 816 Required Privilege Level | 816 Sample Output | 817 Release Information | 823
Syntax
show system boot-messages

814
Syntax (EX Series Switches)
show system boot-messages <all-members> <local> <member member-id>
Syntax (TX Matrix Router)
show system boot-messages <all-chassis | all-lcc | lcc number | scc>
Syntax (TX Matrix Plus Router)
show system boot-messages <all-chassis | all-lcc | lcc number | sfc number>
Syntax (MX Series Router)
show system boot-messages <all-members> <local> <member member-id>

815
Syntax (QFX Series)
show system boot-messages infrastructure name | interconnect-device name | node-group name

Description
This command displays initial messages generated by the system kernel upon startup. These messages are the contents of /var/run/dmesg.boot.

Options
none all-chassis all-lcc
all-members infrastructure name interconnectdevice name lcc number

Display all boot time messages.
(TX Matrix routers andTX Matrix Plus routers only) (Optional) Display boot time messages for all of the chassis.
(TX Matrix routers and TX Matrix Plus routers only) (Optional) On a TX Matrix router, display boot time messages for all T640 routers connected to a TX Matrix router. On a TX Matrix Plus router, display boot time messages for all connected T1600 or T4000 LCCs.
(EX4200 switches and MX Series routers only) (Optional) Display boot time messages on all members of the Virtual Chassis configuration.
(QFabric systems only) (Optional) Display boot time messages on the fabric control Routing Engine or fabric manager Routing engines.
(QFabric systems only) (Optional) Display boot time messages on the Interconnect device.
(TX Matrix routers and TX Matrix Plus routers only) (Optional) On a TX Matrix router, display boot time messages for a specific T640 router connected to a TX Matrix router. On a TX Matrix Plus router, display boot time messages for a specific router connected to a TX Matrix Plus router.
Replace number with the following values depending on the LCC configuration:

816

· 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

· 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

· 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

· 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

local

(EX4200 switches and MX Series routers only) (Optional) Display boot time messages on the local Virtual Chassis member.

member memberid

(EX4200 switches and MX Series routers only) (Optional) Display boot time messages on the specified member of the Virtual Chassis configuration. For EX4200 switches, replace member-id with a value from 0 through 9. For an MX Series Virtual Chassis, replace member-id with a value of 0 or 1.

node-group name (QFabric systems only) (Optional) Display boot time messages on the Node group.

scc

(TX Matrix routers only) (Optional) Display boot time messages for the TX Matrix

router (or switch-card chassis).

sfc number

(TX Matrix Plus routers only) (Optional) Display boot time messages for the TX Matrix Plus router. Replace number with 0.

Additional Information
By default, when you issue the show system boot-messages command on the primary Routing Engine of a TX Matrix router or a TX Matrix Plus router, the command is broadcast to all the primary Routing Engines of the LCCs connected to it in the routing matrix. Likewise, if you issue the same command on the backup Routing Engine of a TX Matrix or a TX Matrix Plus router, the command is broadcast to all backup Routing Engines of the LCCs that are connected to it in the routing matrix.
Required Privilege Level
view

817

Sample Output
show system boot-messages (TX Matrix Router)

user@host> show system boot-messages Copyright (c) 1992-1998 FreeBSD Inc. Copyright (c) 1996-2000 Juniper Networks, Inc. All rights reserved. Copyright (c) 1982, 1986, 1989, 1991, 1993
The Regents of the University of California.

All rights reserved.

JUNOS 4.1-20000216-Zf8469 #0: 2000-02-16 12:57:28 UTC tlim@device1.example.com:/p/build/20000216-0905/4.1/release_kernel/sys/compil
e/GENERIC CPU: Pentium Pro (332.55-MHz 686-class CPU)
Origin = "GenuineIntel" Id = 0x66a Stepping=10 Features=0x183f9ff<FPU,VME,DE,PSE,TSC,MSR,PAE,MCE,CX8,SEP,MTRR,PGE,MCA,CMOV,<b 16>,<b17>,MMX,<b24>> Teknor CPU Card Recognized real memory = 805306368 (786432K bytes) avail memory = 786280448 (767852K bytes) Probing for devices on PCI bus 0: chip0 <generic PCI bridge (vendor=8086 device=7192 subclass=0)> rev 3 class 6000 0 on pci0:0:0 chip1 <Intel 82371AB PCI-ISA bridge> rev 1 class 60100 on pci0:7:0 chip2 <Intel 82371AB IDE interface> rev 1 class 10180 on pci0:7:1 chip3 <Intel 82371AB USB interface> rev 1 class c0300 int d irq 11 on pci0:7:2 smb0 <Intel 82371AB SMB controller> rev 1 class 68000 on pci0:7:3 pcic0 <TI PCI-1131 PCI-CardBus Bridge> rev 1 class 60700 int a irq 15 on pci0:13 :0 TI1131 PCI Config Reg: [pci only][FUNC0 pci int] pcic1 <TI PCI-1131 PCI-CardBus Bridge> rev 1 class 60700 int b irq 12 on pci0:13 :1 TI1131 PCI Config Reg: [pci only][FUNC1 pci int] fxp0 <Intel EtherExpress Pro 10/100B Ethernet> rev 8 class 20000 int a irq 12 on pci0:16:0 chip4 <generic PCI bridge (vendor=1011 device=0022 subclass=4)> rev 4 class 6040 0 on pci0:17:0 fxp1 <Intel EtherExpress Pro 10/100B Ethernet> rev 8 class 20000 int a irq 10 on pci0:19:0 Probing for devices on PCI bus 1:

818
mcs0 <Miscellaneous Control Subsystem> rev 12 class ff0000 int a irq 12 on pci1: 13:0 fxp2 <Intel EtherExpress Pro 10/100B Ethernet> rev 8 class 20000 int a irq 10 on
pci1:14:0 Probing for devices on the ISA bus: sc0 at 0x60-0x6f irq 1 on motherboard sc0: EGA color <16 virtual consoles, flags=0x0> ed0 not found at 0x300 ed1 not found at 0x280 ed2 not found at 0x340 psm0 not found at 0x60 sio0 at 0x3f8-0x3ff irq 4 flags 0x20010 on isa sio0: type 16550A, console sio1 at 0x3e8-0x3ef irq 5 flags 0x20000 on isa sio1: type 16550A sio2 at 0x2f8-0x2ff irq 3 flags 0x20000 on isa sio2: type 16550A pcic0 at 0x3e0-0x3e1 on isa PC-Card ctlr(0) TI PCI-1131 [CardBus bridge mode] (5 mem & 2 I/O windows) pcic0: slot 0 controller I/O address 0x3e0 npx0 flags 0x1 on motherboard npx0: INT 16 interface fdc0: direction bit not set fdc0: cmd 3 failed at out byte 1 of 3 fdc0 not found at 0x3f0 wdc0 at 0x1f0-0x1f7 irq 14 on isa wdc0: unit 0 (wd0): <SunDisk SQFXB-80>, single-sector-i/o wd0: 76MB (156672 sectors), 612 cyls, 8 heads, 32 S/T, 512 B/S wdc0: unit 1 (wd1): <IBM-DCXA-210000> wd1: 8063MB (16514064 sectors), 16383 cyls, 16 heads, 63 S/T, 512 B/S wdc1 not found at 0x170 wdc2 not found at 0x180 ep0 not found at 0x300 fxp0: Ethernet address 00:a0:a5:12:05:5a fxp1: Ethernet address 00:a0:a5:12:05:59 fxp2: Ethernet address 02:00:00:00:00:01 swapon: adding /dev/wd1s1b as swap device Automatic reboot in progress... /dev/rwd0s1a: clean, 16599 free (95 frags, 2063 blocks, 0.1% fragmentation) /dev/rwd0s1e: clean, 9233 free (9 frags, 1153 blocks, 0.1% fragmentation) /dev/rwd0s1a: clean, 16599 free (95 frags, 2063 blocks, 0.1% fragmentation) /dev/rwd1s1f: clean, 4301055 free (335 frags, 537590 blocks, 0.0% fragmentation)

819
show system boot-messages lcc (TX Matrix Router)
user@host> show system boot-messages lcc 2 lcc2-re0: -------------------------------------------------------------------------Copyright (c) 1996-2001, Juniper Networks, Inc. All rights reserved. Copyright (c) 1992-2001 The FreeBSD Project. Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994
The Regents of the University of California. All rights reserved. JUNOS 7.0-20040912.0 #0: 2004-09-12 09:16:32 UTC
builder@device1.example.com:/build/benten-b/7.0/20040912.0/obj-i386/sys/compile/ JUNIPER Timecounter "i8254" frequency 1193182 Hz Timecounter "TSC" frequency 601368936 Hz CPU: Pentium III/Pentium III Xeon/Celeron (601.37-MHz 686-class CPU)
Origin = "GenuineIntel" Id = 0x68a Stepping = 10
Features=0x387f9ff<FPU,VME,DE,PSE,TSC,MSR,PAE,MCE,CX8,SEP,MTRR,PGE,MCA,CMOV,PAT,P SE36,PN,MMX,FXSR,SSE> real memory = 2147467264 (2097136K bytes) sio0: gdb debugging port avail memory = 2084040704 (2035196K bytes) Preloaded elf kernel "kernel" at 0xc06d9000. DEVFS: ready for devices Pentium Pro MTRR support enabled md0: Malloc disk DRAM Data Integrity Mode: ECC Mode with h/w scrubbing npx0: <math processor> on motherboard npx0: INT 16 interface pcib0: <ServerWorks NB6635 3.0LE host to PCI bridge> on motherboard pci0: <PCI bus> on pcib0 pcic-pci0: <TI PCI-1410 PCI-CardBus Bridge> irq 15 at device 1.0 on pci0 pcic-pci0: TI12XX PCI Config Reg: [pwr save][pci only] fxp0: <Intel Embedded 10/100 Ethernet> port 0x1000-0x103f mem 0xfb800000-0xfb81ffff,0xfb820000-0xfb820fff irq 9 at device 3.0 on pci0 fxp1: <Intel Embedded 10/100 Ethernet> port 0x1040-0x107f mem 0xfb840000-0xfb85ffff,0xfb821000-0xfb821fff irq 11 at device 4.0 on pci0 ...

820

show system boot-messages (TX Matrix Plus Router)

user@host> show system boot-messages

sfc0-re0:

--------------------------------------------------------------------------

Copyright (c) 1996-2009, Juniper Networks, Inc.

All rights reserved.

Copyright (c) 1992-2006 The FreeBSD Project.

Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994

The Regents of the University of California. All rights reserved.

JUNOS 9.6B3.3 #0: 2009-06-17 19:52:08 UTC

builder@device1.example.com:/volume/build/junos/9.6/release/9.6B3.3/obj-

i386/bsd/sys/compile/JUNIPER

MPTable: Timecounter "i8254" frequency 1193182 Hz quality 0 CPU: Intel(R)

Xeon(R) CPU

L5238 @ 2.66GHz (2660.01-MHz 686-class CPU) Origin =

"GenuineIntel" Id = 0x1067a Stepping = 10 Features=0xbfebfbff

...

lcc1-re0:

--------------------------------------------------------------------------

Copyright (c) 1996-2009, Juniper Networks, Inc.

All rights reserved.

Copyright (c) 1992-2006 The FreeBSD Project.

Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994

The Regents of the University of California. All rights reserved.

JUNOS 9.6-20090617.0 #0: 2009-06-17 04:15:14 UTC

builder@device1.example.com:/volume/build/junos/9.6/production/20090617.0/

obj-i386/bsd/sys/compile/JUNIPER

Timecounter "i8254" frequency 1193182 Hz quality 0

CPU: Intel(R) Xeon(R) CPU

@ 1.86GHz (1862.01-MHz 686-class CPU)

Origin = "GenuineIntel" Id = 0x1067a Stepping = 10

Features=0xbfebfbff

...

show system boot-messages (QFX3500 Switch)

user@switch> show sytem boot-messages getmemsize: msgbufp[size=32768] = 0x81d07fe4
System physical memory distribution: -------------------------------------------------------------------------------

821
Total physical memory: 4160749568 (3968 MB) Physical memory used: 3472883712 (3312 MB) Physical memory allocated to kernel: 2130706432 (2032 MB) Physical memory allocated to user BTLB: 1342177280 (1280 MB) -------------------------------------------------------------------------------
Copyright (c) 1996-2010, Juniper Networks, Inc. All rights reserved. Copyright (c) 1992-2006 The FreeBSD Project. Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994
The Regents of the University of California. All rights reserved. JUNOS 11.1I #0: 2010-09-17 19:18:07 UTC
ssiano@device1.example.com:/c/ssiano/DEV_QFX_SI_BRANCH/03/20100917.399988/ obj-xlr/bsd/sys/compile/JUNIPER-DCTOR WARNING: debug.mpsafenet forced to 0 as ipsec requires Giant JUNOS 11.1I #0: 2010-09-17 19:18:07 UTC
ssiano@device1.example.com:/c/ssiano/DEV_QFX_SI_BRANCH/03/20100917.399988/ obj-xlr/bsd/sys/compile/JUNIPER-DCTOR real memory = 3472883712 (3312MB) avail memory = 1708171264 (1629MB) cpuid: 0, btlb_cpumap:0xfffffff8 FreeBSD/SMP: Multiprocessor System Detected: 12 CPUs ETHERNET SOCKET BRIDGE initialising Initializing QFX platform properties .. cpu0 on motherboard : RMI's XLR CPU Rev. 0.3 with no FPU implemented
L1 Cache: I size 32kb(32 line), D size 32kb(32 line), eight way. L2 Cache: Size 1024kb, eight way pic_lbus0: <XLR Local Bus> pic_lbus0: <XLR Local Bus> on motherboard Enter qfx control ethernet probe addr:0xc5eeec00 gmac4: <XLR GMAC GE Ethernet> on pic_lbus0 me0: Ethernet address 00:1d:b5:f7:68:40 Enter qfx control ethernet probe addr:0xc5eeeb40 gmac5: <XLR GMAC GE Ethernet> on pic_lbus0 me1: Ethernet address 00:1d:b5:f7:68:41 Enter qfx control ethernet probe addr:0xc5eeea80 gmac6: <XLR GMAC GE Ethernet> on pic_lbus0 me1: Ethernet address 00:1d:b5:f7:68:42 sio0 on pic_lbus0 Entering sioattach sio0: type 16550A, console xls_setup_intr: skip irq 3, xlr regs are set up somewhere else.

822
gblmem0 on pic_lbus0 ehci0: <RMI XLS USB 2.0 controller> on pic_lbus0 ehci_bus_attach: allocated resource. tag=1, base=bef24000 xls_ehci_init: endian hardware swapping NOT enabled. usb0: EHCI version 1.0 usb0 on ehci0 usb0: USB revision 2.0 uhub0: vendor 0x0000 EHCI root hub, class 9/0, rev 2.00/1.00, addr 1 uhub0: 2 ports with 2 removable, self powered umass0: USB USBFlashDrive, rev 2.00/11.00, addr 2 pcib0: PCIe link 0 up pcib0: PCIe link 2 up pcib0: PCIe link 3 up pcib0: <XLS PCI Host Controller> on pic_lbus0 pci0: <PCI bus> on pcib0 pcib1: <PCI-PCI bridge> at device 0.0 on pci0 pci1: <PCI bus> on pcib1 pci1: <network, ethernet> at device 0.0 (no driver attached) pcib2: <PCI-PCI bridge> at device 1.0 on pci0 pcib3: <PCI-PCI bridge> at device 2.0 on pci0 pci2: <PCI bus> on pcib3 pci2: <network, ethernet> at device 0.0 (no driver attached) pcib4: <PCI-PCI bridge> at device 3.0 on pci0 pci3: <PCI bus> on pcib4 pci3: <network, ethernet> at device 0.0 (no driver attached) cfi device address space at 0xbc000000 cfi0: <AMD/Fujitsu - 8MB> on pic_lbus0 cfi device address space at 0xbc000000 i2c0: <I2C bus controller> on pic_lbus0 i2c1: <I2C bus controller> on pic_lbus0 qfx_fmn0 on pic_lbus0 pool offset 1503776768 xlr_lbus0: <XLR Local Bus Controller> on motherboard qfx_bcpld_probe[124] qfx_bcpld_probe[138]: dev_type=0x0 qfx_bcpld_probe[124] qfx_bcpld0: QFX BCPLD probe success qfx_bcpld0qfx_bcpld_attach[174] qfx_bcpld_attach[207] : bus_space_tag=0x0, bus_space_handle=0xbd900000 qfx_bcpld_probe[124] qfx_bcpld1: QFX BCPLD probe success qfx_bcpld1qfx_bcpld_attach[174] tor_bcpld_slave_attach[1245] : bus_space_tag=0x0, bus_space_handle=0xbda00000

823
Initializing product: 96 .. bmeb: bmeb_lib_init done 0xc60a5000, addr 0x809c99a0 bme0:Virtual BME driver initializing Timecounter "mips" frequency 1200000000 Hz quality 0 Timecounter "xlr_pic_timer" frequency 66666666 Hz quality 1 Timecounters tick every 1.000 msec Loading the NETPFE fc module IPsec: Initialized Security Association Processing. SMP: AP CPU #3 Launched! SMP: AP CPU #1 Launched! SMP: AP CPU #2 Launched! SMP: AP CPU #4 Launched! SMP: AP CPU #5 Launched! SMP: AP CPU #7 Launched! SMP: AP CPU #6 Launched! SMP: AP CPU #11 Launched! SMP: AP CPU #10 Launched! SMP: AP CPU #9 Launched! SMP: AP CPU #8 Launched! da0 at umass-sim0 bus 0 target 0 lun 0 da0: <USB USBFlashDrive 1100> Removable Direct Access SCSI-0 device da0: 40.000MB/s transfers da0: 3920MB (8028160 512 byte sectors: 255H 63S/T 499C) Trying to mount root from ufs:/dev/da0s1a
Release Information
Command introduced before Junos OS Release 7.4. sfc option introduced for the TX Matrix Plus router in Junos OS Release 9.6.
RELATED DOCUMENTATION Routing Matrix with a TX Matrix Plus Router Solutions Page

824
show system auto-snapshot
IN THIS SECTION Syntax | 824 Description | 824 Options | 824 Required Privilege Level | 824 Output Fields | 825 Sample Output | 825 Release Information | 826
Syntax
show system auto-snapshot
Description
This command displays automatic snapshot status information.
Options
This command has no options.
Required Privilege Level
view

825

Output Fields

Table 35 on page 825 describes the output fields for the show system auto-snapshot command. Output fields are listed in the approximate order in which they appear.
Table 35: show system auto-snapshot status Output Fields

Field Name

Field Description

Auto-snapshot configuration

Status of the configuration:
· Enabled--If the system reboots from the alternate partition, the automatic snapshot feature automatically takes a snapshot of the alternate partition and copies it onto the primary partition.
· Disabled--The system does not automatically take a snapshot of the alternate partition. You must use the manual snapshot command, request system snapshot, to take a snapshot of one partition and copy it onto the other.

Auto-snapshot state

Status of the automatic snapshot procedure:
· Completed--The automatic snapshot procedure has completed copying the alternate partition to the primary partition and the alarm has been cleared.
· Disabled--The automatic snapshot procedure is inactive.
· In progress--The automatic snapshot procedure is in progress. It takes about 10 to 15 minutes to complete, depending upon disk size.

Sample Output
show system auto-snapshot
user@switch> show system auto-snapshot Auto-snapshot Configuration: Enabled Auto-snapshot State: Disabled

826
Release Information
Command introduced in Junos OS Release 12.3.
RELATED DOCUMENTATION Configuring Dual-Root Partitions | 365
show system download
IN THIS SECTION Syntax | 826 Description | 826 Options | 827 Required Privilege Level | 827 Output Fields | 827 Sample Output | 828 Release Information | 828
Syntax
show system download <download-id>
Description
This command displays a brief summary of all the download instances along with their current state and extent of progress. If a download-id is provided, the command displays a detailed report of the particular download instance.

827
Options
· download-id--(Optional) The ID number of the download instance.

Required Privilege Level
view

Output Fields

Table 36 on page 827 lists the output fields for the show system download command. Output fields are listed in the approximate order in which they appear.
Table 36: show system download Output Fields

Field Name

Field Description

ID

Displays the download identification number.

Status

Displays the state of a particular download.

Start Time

Displays the start time of a particular download.

Progress

Displays the percentage of a download that has been completed.

URL

Displays the URL from which the file was downloaded.

828

Sample Output
show system download

user@host> show system download

Download Status Information:

ID Status

Start Time

1 Active

May 4 06:28:36

2 Active

May 4 06:29:07

3 Error

May 4 06:29:22

4 Completed May 4 06:29:40

Progress 5% 3% Unknown 100%

URL ftp://ftp-server//tftpboot/1m_file ftp://ftp-server//tftpboot/5m_file ftp://ftp-server//tftpboot/badfile ftp://ftp-server//tftpboot/smallfile

show system download 1

user@host> show system download 1

Download ID Status Progress URL Local Path Maximum Rate Creation Time Scheduled Time Start Time Error Count

: 1 : Active : 6% : ftp://ftp-server//tftpboot/1m_file : /var/tmp/1m_file : 1k : May 4 06:28:36 : May 4 06:28:36 : May 4 06:28:37 : 0

Release Information
Command introduced in Junos OS Release 15.1X49-D35.
RELATED DOCUMENTATION request system download start | 619

829
show system login lockout
IN THIS SECTION Syntax | 829 Description | 829 Required Privilege Level | 829 Output Fields | 829 Sample Output | 830 Release Information | 830
Syntax
show system login lockout
Description
This command displays the usernames locked after unsuccessful login attempts.
Required Privilege Level
view and system
Output Fields
Table 37 on page 830 lists the output fields for the show system login lockout command. Output fields are listed in the approximate order in which they appear.

Table 37: show system login lockout

Field Name

Field Description

User

Username

Lockout start Date and time the username was locked

Lockout end

Date and time the username was unlocked

830
Level of Output All levels All levels All levels

Sample Output
show system login lockout

user@host> show system login lockout

User root

Lockout start

Lockout end

2011-05-11 09:11:15 UTC 2011-05-11 09:13:15 UTC

Release Information
Command introduced in Junos OS Release 11.2.
RELATED DOCUMENTATION retry-options clear system login lockout | 593

831
show system rollback
IN THIS SECTION Syntax | 831 Description | 831 Options | 831 Required Privilege Level | 832 Sample Output | 832 Sample Output | 833 Release Information | 833

Syntax
show system rollback number <compare number | configuration-revision>

Description
This command displays the contents of a previously committed configuration, or the differences between two previously committed configurations. The show system rollback command is a operational mode command and cannot be issued with run from the configuration mode.

Options
number

Number of a configuration to view. The output displays the configuration. The range of values is 0 through 49.

832

compare number configurationrevision

(Optional) Number of another previously committed (rollback) configuration to compare to rollback number. The output displays the differences between the two configurations. The range of values is 0 through 49.
(Optional) Display corresponding configuration revision for this rollback number.

Required Privilege Level
view

Sample Output
show system rollback compare

user@host> show system rollback 3 compare 1

[edit]

+ interfaces {

+

ge-1/1/1 {

+

unit 0 {

+

family inet {

+

filter {

+

input mf_plp;

+

}

+

address 10.1.1.1/10;

+

}

+

}

+

}

+

ge-1/2/1 {

+

unit 0 {

+

family inet {

+

filter {

+

input mf_plp;

+

}

+

address 10.1.1.1/10;

+

}

+

}

+

}

833

+

ge-1/3/0 {

+

unit 0 {

+

family inet {

+

filter {

+

input mf_plp;

+

}

+

address 10.1.1.1/10;

+

}

+

}

+

}

+}

Sample Output
show system rollback configuration-revision
user@host> show system rollback 0 configuration-revision The corresponding configuration revision is: re0-1596379942-3

Release Information
Command introduced before Junos OS Release 7.4. Option configuration-revision introduced in Junos OS Release 20.4R1 and Junos OS Evolved Release 20.4R1.
show system snapshot

IN THIS SECTION Syntax | 834

834
Syntax (EX Series Switches) | 834 Description | 834 Options | 835 Required Privilege Level | 835 Output Fields | 835 Sample Output | 836 Release Information | 838
Syntax
show system snapshot
Syntax (EX Series Switches)
show system snapshot <all-members | local | member member-id> <media (external | internal)>
Description
This command displays information about the backup software: · On the routers, this command display information about the backup software, which is located in
the /altroot, and /altconfig file systems or on the alternate media. · On the switches, this command display information about the backup of the root file system (/) and
directories /altroot,/config, /var, and /var/tmp, which are located either on an external USB flash drive or in internal flash memory. To back up software, use the request system snapshot command.

835

Options

none

Display information about the backup software.

all-members | local | member member-id

(EX Series switch Virtual Chassis only) (Optional) Display the snapshot in a Virtual Chassis:
· all-members--Display the snapshot for all members of the Virtual Chassis.

· local--Display the snapshot on the member of the Virtual Chassis that you are currently logged into.

· member member-id--Display the snapshot for the specified member of the Virtual Chassis.

media (external | internal)

(EX Series switch only) (Optional) Display the destination media location for the snapshot. The external option specifies the snapshot on an external mass storage device, such as a USB flash drive. The internal option specifies the snapshot on an internal memory source, such as internal flash memory. If no additional options are specified, the command displays the snapshot stored in both slices.

Required Privilege Level
view

Output Fields

Table 38 on page 835 lists the output fields for the show system snapshot command. Output fields are listed in the approximate order in which they appear.
Table 38: show system snapshot Output Fields

Field Name

Field Description

Creation date

Date and time of the last snapshot.

836

Table 38: show system snapshot Output Fields (Continued)

Field Name

Field Description

JUNOS version on snapshot

Junos OS release number of individual software packages.

Sample Output
show system snapshot (Router)
user@host> show system snapshot Information for snapshot on hard-disk Creation date: Oct 5 13:53:29 2005 JUNOS version on snapshot:
jbase : 7.3R2.5 jcrypto: 7.3R2.5 jdocs : 7.3R2.5 jkernel: 7.3R2.5 jpfe : M40-7.3R2.5 jroute : 7.3R2.5
show system snapshot (Junos OS Evolved)
user@host> show system snapshot ------------------------------node: re0 ------------------------------Current snapshot device: /dev/sdb Snapshot boot device: sdb List of installed version(s) in Snapshot boot device sdb: [1] -> junos-linux-install-ptx-fixed-x86-64-18.4-20180819.2 -
[2018-08-21 07:26:13] '-' running version

837

'>' next boot version '<' rollback boot version

show system snapshot media external (Switch)

user@switch> show system snapshot media external

Information for snapshot on

external (/dev/da1s1a) (backup)

Creation date: Mar 19 03:37:18 2012

JUNOS version on snapshot:

jbase : ex-12.1I20120111_0048_user

jcrypto-ex: 12.1I20120111_0048_user

jdocs-ex: 12.1I20120111_0048_user

jroute-ex: 12.1I20120111_0048_user

jswitch-ex: 12.1I20120111_0048_user

jweb-ex: 12.1I20120111_0048_user

Information for snapshot on

external (/dev/da1s2a) (primary)

Creation date: Mar 19 03:38:25 2012

JUNOS version on snapshot:

jbase : ex-12.2I20120305_2240_user

jcrypto-ex: 12.2I20120305_2240_user

jdocs-ex: 12.2I20120305_2240_user

jroute-ex: 12.2I20120305_2240_user

jswitch-ex: 12.2I20120305_2240_user

jweb-ex: 12.2I20120305_2240_user

show system snapshot media internal (Switch)
user@switch> show system snapshot media internal Information for snapshot on internal (/dev/da0s1a) (backup) Creation date: Mar 14 05:01:02 2011 JUNOS version on snapshot:
jbase : 11.1R1.9 jcrypto-ex: 11.1R1.9 jdocs-ex: 11.1R1.9 jkernel-ex: 11.1R1.9 jroute-ex: 11.1R1.9 jswitch-ex: 11.1R1.9 jweb-ex: 11.1R1.9 jpfe-ex42x: 11.1R1.9

838
Information for snapshot on internal (/dev/da0s2a) (primary) Creation date: Mar 30 08:46:27 2011 JUNOS version on snapshot:
jbase : 11.2-20110330.0 jcrypto-ex: 11.2-20110330.0 jdocs-ex: 11.2-20110330.0 jkernel-ex: 11.2-20110330.0 jroute-ex: 11.2-20110330.0 jswitch-ex: 11.2-20110330.0 jweb-ex: 11.2-20110330.0 jpfe-ex42x: 11.2-20110330.0
Release Information
Command introduced in Junos OS Release 7.6. Option slice deprecated for Junos OS with Upgraded FreeBSD in Junos OS Release 15.1. You can find which platforms run Junos OS with Upgraded FreeBSD here: Release Information for Junos OS with Upgraded FreeBSD.
RELATED DOCUMENTATION request system snapshot | 655
show system snapshot (Junos OS with Upgraded FreeBSD)
IN THIS SECTION Syntax | 839 Description | 839 Required Privilege Level | 839

839
Output Fields | 839 Sample Output | 840 Sample Output | 840 Release Information | 841
Syntax
show system snapshot
Description
This command displays information about the non-recovery backup software, which is located in the junos file system on the hard disk drive or solid-state drive (SSD). This command displays information about recovery snapshot after the non-recovery information. To back up software, use the request system snapshot command.
Required Privilege Level
view
Output Fields
When you enter this command, you are provided feedback on the status of your request. If there are no snapshots available, the command returns null output.

840
Sample Output
show system snapshot
user@host> show system snapshot Snapshot snap.20141219.122106: Location: /packages/sets/snap.20141219.122106 Creation date: Dec 19 12:21:06 2014 Junos version: 15.1-20141216_ib_15_1_psd.0

Sample Output
show system snapshot (updated as of Junos OS Release 17.2)

user@host> show system snapshot Non-recovery snapshots:

Snapshot snap.20170112.105151: Location: /packages/sets/snap.20170112.105151 Creation date: Jan 12 10:51:51 2017 Junos version: 17.2I20170112_0239

Snapshot snap.20170112.112307: Location: /packages/sets/snap.20170112.112307 Creation date: Jan 12 11:23:07 2017 Junos version: 17.2I20170112_0239

Snapshot snap.20170112.112314: Location: /packages/sets/snap.20170112.112314 Creation date: Jan 12 11:23:14 2017 Junos version: 17.2I20170112_0239

Total non-recovery snapshots:

3

Recovery Snapshots: Snapshots available on the OAM volume: recovery.ufs Date created: Wed Jan 11 15:59:35 PST 2017

841
Junos version: 17.2I20170111_2242 Total recovery snapshots: 1
Release Information
Command introduced starting in Junos OS Release 15.1 for supported platforms. See Feature Explorer. Output for recovery snapshots provided in Junos Release 17.2 for all the devices using Junos OS with upgraded FreeBSD.
RELATED DOCUMENTATION request system snapshot (Junos OS with Upgraded FreeBSD) | 668 request system reboot (Junos OS with Upgraded FreeBSD) | 643 Release Information for Junos OS with Upgraded FreeBSD
show system snapshot media
IN THIS SECTION Syntax | 842 Description | 842 Options | 842 Required Privilege Level | 842 Output Fields | 843 Sample Output | 843 Release Information | 844

842
Syntax
show system snapshot < media (compact-flash | external | harddisk | internal | usb) >
Description
This command displays information about the partitioning scheme present on the media. Information for only one root is displayed for single-root partitioning, whereas information for both roots is displayed for dual-root partitioning.
Options
· compact-flash-- Show snapshot information from the CompactFlash card. (Supported on SRX5400, SRX5600, SRX5800)
· external-- Show snapshot information from the external CompactFlash card. (Not supported on SRX5000 Series devices)
· hard-disk-- Show snapshot information from the Hard Disk. (Supported on SRX5400, SRX5600, SRX5800)
· internal-- Show snapshot information from internal media. (Not supported on SRX5000 Series devices)
· usb-- Show snapshot information from device connected to USB port.
Required Privilege Level
View

843

Output Fields

Table 39 on page 843 lists the output fields for the show system snapshot media command. Output fields are listed in the approximate order in which they appear.
Table 39: show system snapshot media Output Fields

Field Name

Field Description

Creation date

Date and time of the last snapshot.

JUNOS version on snapshot

Junos OS release number of individual software packages.

Sample Output
show system snapshot media compact-flash

show system snapshot media compact-flash Information for snapshot on compact-flash (ad0s1) Creation date: Aug 21 11:58:14 2017 JUNOS version on snapshot:
junos : 12.3X48-D40.5-domestic

show system snapshot media external

show system snapshot media external

Information for snapshot on

external (/dev/da1s2a) (primary)

Creation date: Apr 9 09:41:16 2018

JUNOS version on snapshot:

junos : 12.3X48-D40.5-domestic

Information for snapshot on

external (/dev/da1s1a) (backup)

Creation date: Apr 9 09:41:16 2018

JUNOS version on snapshot:

junos : 12.3X48-D40.5-domestic

844

show system snapshot media internal

show system snapshot media internal

Information for snapshot on

internal (/dev/da0s1a) (primary)

Creation date: Jan 15 10:43:26 2010

JUNOS version on snapshot:

junos : 10.1B3-domestic

Information for snapshot on

internal (/dev/da0s2a) (backup)

Creation date: Jan 15 10:15:32 2010

JUNOS version on snapshot:

junos : 10.2-20100112.0-domestic

show system snapshot media usb

show system snapshot media usb Information for snapshot on usb (da0s1) Creation date: Apr 9 08:44:46 2018 JUNOS version on snapshot:
junos : 12.3X48-D40.5-domestic

show system snapshot media hard-disk

show system snapshot media hard-disk Information for snapshot on hard-disk (ad2s1) Creation date: Apr 9 16:40:18 2018 JUNOS version on snapshot:
junos : 12.3X48-D40.5-domestic

Release Information
Command introduced in Junos OS Release 10.2 .
RELATED DOCUMENTATION Creating a Snapshot and Using It to Boot an SRX Series device | 15

845
show system software list
IN THIS SECTION Syntax | 845 Description | 845 Required Privilege Level | 845 Output Fields | 846 Sample Output | 846 Release Information | 847
Syntax
show system software list
Description
This command displays all the software versions in the persistent storage on the Routing Engines in the system and displays the current software version running on the FPCs. FPCs cannot store more than one version, because they do not contain any persistent storage media.
Required Privilege Level
view

846

Output Fields

For a description of the output fields, see Table 40 on page 846. Output fields are listed in the approximate order in which they appear.
Table 40: show system software list Output Fields

Field Name

Description

node

Name of the node.

List of installed version(s)

Ordered list of software that is or has been installed on the node:
· - indicates the running software version.
· > indicates the next boot software version, which occurs only after an upgrade or a downgrade. If no upgrade or downgrade has been performed, the > symbol will not appear in the list of installed versions.
· < indicates the rollback boot software version if there is one.

Sample Output
show system software list
user@host> show system software list ------------------------------node: RE0 ------------------------------Active boot device is primary: /dev/sda List of installed version(s) :
'-' running version '>' next boot version after upgrade/downgrade '<' rollback boot version
- junos-evo-install-ptx-fixed-x86-64-18.4-20181211.1 - [2018-11-23 00:06:02]

847
< junos-evo-install-ptx-fixed-x86-64-18.4-20181122.2 - [2018-11-22 19:03:02]
junos-evo-install-ptx-fixed-x86-64-18.3-20181122.2 - [2018-11-22 16:34:59]
Release Information
Command introduced in Junos OS Evolved Release 18.3R1.
show system software restore-point-status
IN THIS SECTION Syntax | 847 Description | 848 Required Privilege Level | 848 Output Fields | 848 Sample Output | 849 Release Information | 849
Syntax
show system software restore-point-status

848
Description
This command displays the status of the restore-point for QFabric system. A restore-point contains both a snapshot of the software and a configuration file. You can create only one restore-point. When you create a new restore-point, the existing restore-point, if available, is erased.

Required Privilege Level
view

Output Fields

Table 41 on page 848 lists the output fields for the show system software restore-point status command. Output fields are listed in the approximate order in which they appear.
Table 41: show system software restore-point status Output Fields

Field Name

Field Description

Member

Name of the Director device.

Creation Time

Time when the restore-point was created.

Status

Status of restore-point creation.

Restore volume

Name and path to restore volume used to create the restore-point.

849

Sample Output
show system software restore-point status

user@qfabric> show system software restore-point status

Member

Creation Time

Status

------

-------------

-----

dg0

Aug 15 07:42:39 2014

success

dg1

Aug 15 07:42:27 2014

success

Restore volume ---------------
/dev/VolGroup00/LogVol03 /dev/VolGroup00/LogVol03

Release Information
Command introduced in Junos OS Release 14.1X53-D15.
RELATED DOCUMENTATION request system software restore-point | 723
show system software usb-software-version

IN THIS SECTION
Syntax | 850 Description | 850 Additional Information | 850 Required Privilege Level | 850 Output Fields | 850 Sample Output | 851 Release Information | 851

850
Syntax
show system software usb-software-version

Description
This comamnd displays the version of software present on a standard USB installer key attached to each Director Group (DG) device (QFabric systems only).
Additional Information
When issuing the show system software usb-software-version command, the USB installer key must be attached to the DGs. The format of the USB installer key (including partitions) must conform to the standard specifications of the Juniper-provided USB installer. A Juniper-provided or Juniper-recommended USB installer device must have the following partitions:

Device /dev/sdb1 /dev/sdb2

Boot *

Start 1 76

End 75
709

Blocks 295244
2496058

Id System 4 FAT16 <32M
83 Linux

Required Privilege Level
view
Output Fields
Table 42 on page 851 lists the output fields for the show system software usb-software-version command. Output fields are listed in the approximate order in which they appear.

851

Table 42: show system software usb-software-version Output Fields

Field Name

Field Description

Node

Node supporting the device.

Device

Device on which the software is present.

Version

Version of the software present.

Filename

Software filename.

Sample Output
show system software usb-software-version

user@host> show system software usb-software-version

NODE

DEVICE

VERSION

----

------

-------

dg0 /dev/sdb

14.1-20160516_x141X53_vjqfd.0

qfabric-14.1-20160516_x141X53_vjqfd.0.rpm

dg1 /dev/sdb

14.1-20160516_x141X53_vjqfd.0

qfabric-14.1-20160516_x141X53_vjqfd.0.rpm

FILENAME
-------jinstall-
jinstall-

Release Information
Command introduced in Junos OS Release 14.1X53-D40.

852
RELATED DOCUMENTATION Performing a Nonstop Software Upgrade on the QFabric System Verifying Nonstop Software Upgrade for QFabric Systems Upgrading Software on a QFabric System
show system storage partitions
IN THIS SECTION Syntax (EX Series) | 852 Syntax (SRX Series) | 852 Description | 853 Options | 853 Required Privilege Level | 853 Output Fields | 853 Sample Output | 854 Release Information | 856
Syntax (EX Series)
show system storage partitions <all-members> <local> <member member-id>
Syntax (SRX Series)
show system storage partitions

853
Description
This command displays information about the disk partitioning scheme.

Options

none

Display partition information.

all-members

(Virtual Chassis systems only) (Optional) Display partition information for all members of the Virtual Chassis.

local

(Virtual Chassis systems only) (Optional) Display partition information for the local Virtual Chassis member.

member member- (Virtual Chassis systems only) (Optional) Display partition information for the

id

specified member of the Virtual Chassis configuration.

Required Privilege Level
view

Output Fields

Table 43 on page 853 describes the output fields for the show system storage partitions command. Output fields are listed in the approximate order in which they appear.
Table 43: show system storage partitions Output Fields

Field Name

Field Description

Boot Media

Media (internal or external) from which the switch was booted.

Active Partition

Name of the active root partition.

854

Table 43: show system storage partitions Output Fields (Continued)

Field Name

Field Description

Backup Partition

Name of the backup (alternate) root partition.

Currently booted from

Partition from which the switch was last booted.

Partitions information

Information about partitions on the boot media: · Partition--Partition identifier. · Size--Size of partition. · Mountpoint--Directory on which the partition is mounted.

Sample Output
show system storage partitions (EX Series)

user@switch> show system storage partitions fpc0: -------------------------------------------------------------------------Boot Media: internal (da0) Active Partition: da0s1a Backup Partition: da0s2a Currently booted from: active (da0s1a)

Partitions information:

Partition Size Mountpoint

s1a

184M /

s2a

184M altroot

s3d

369M /var/tmp

s3e

123M /var

s4d

62M /config

s4e

unused (backup config)

855
show system storage partitions (SRX Series, Dual Root Partitioning)
show system storage partitions Boot Media: internal (da0) Active Partition: da0s2a Backup Partition: da0s1a Currently booted from: active (da0s2a)
Partitions Information: Partition Size Mountpoint s1a 293M altroot s2a 293M / s3e 24M /config s3f 342M /var s4a 30M recovery
show system storage partitions (SRX Series, Single Root Partitioning)
show system storage partitions Boot Media: internal (da0) Partitions Information:
Partition Size Mountpoint s1a 898M / s1e 24M /config s1f 61M /var
show system storage partitions (SRX Series, USB)
show system storage partitions Boot Media: usb (da1) Active Partition: da1s1a Backup Partition: da1s2a Currently booted from: active (da1s1a)
Partitions Information: Partition Size Mountpoint s1a 293M / s2a 293M altroot s3e 24M /config

856
s3f 342M /var s4a 30M recovery
Release Information
Command introduced in Junos OS Release 15.1X49-D35.
RELATED DOCUMENTATION Verifying Junos OS and Boot Loader Software Versions on an EX Series Switch | 101 Example: Installing Junos OS on SRX Series Devices Using the Partition Option | 240 [EX] Switch boots from backup root partition after file system corruption occurred on the primary root partition
show system ztp
IN THIS SECTION Syntax | 856 Description | 857 Required Privilege Level | 857 Output Fields | 857 Sample Output | 861 Release Information | 861
Syntax
show system ztp

857
Description
This command displays the Zero Touch Provisioning (ZTP) state information.

Required Privilege Level
view

Output Fields

For a description of the output fields, see Table 44 on page 857. Output fields are listed in the approximate order in which they appear. The state field can have multiple settings. The rest of the fields are self explanatory based on DHCP arguments provided by the server.
Table 44: show system ztp Output Fields

Field Name

Description

ZtpState

ZTP state field values for starting: · INITIALIZED--ZTP is initializing. · STARTED--ZTP started running.

ZTP state field values for image download:
· IMAGE_DOWNLOADING--ZTP is downloading the next software image.
· IMAGE_DOWNLOADED--ZTP is finished downloading the next software image.
· RETRY_IMAGE_DOWNLOAD--ZTP is retrying image download.
· IMAGE_NOT_FOUND--ZTP could not find the image at the specified location on the server.

858

Table 44: show system ztp Output Fields (Continued)

Field Name

Description

ZTP state field values for configuration download:
· CONFIG_DOWNLOADING--ZTP is downloading the configuration.
· CONFIG_DOWNLOADED--ZTP is finished downloading the configuration.
· RETRY_CONFIG_DOWNLOAD--ZTP is retrying configuration download.
· CONFIG_NOT_FOUND--ZTP could not find the configuration.

ZTP state field values for upgrading configuration:
· IMAGE_CONFIG_UPGRADING--ZTP got an image and a configuration from the server.
· CONFIG_UPGRADING--ZTP is upgrading the configuration.

ZTP state field values for upgrading image:
· RETRY_IMAGE_UPGRADE--ZTP is retrying image upgrade.
· IMAGE_CONFIG_UPGRADING--ZTP got an image and a configuration from the server.
· IMAGE_UPGRADING--ZTP is downloading the image.
· IMAGE_UPGRADED--ZTP is finished upgrading the image.

859

Table 44: show system ztp Output Fields (Continued)

Field Name

Description

ZTP state field values for scripts:
· SCRIPT_UPGRADING--ZTP is running the script provided by server.
· SCRIPT_UPGRADED--ZTP is finished upgrading the script.
· SCRIPT_UPGRADE_SUCCEEDED--ZTP script upgrade finished with success.
· SCRIPT_UPGRADE_FAILED--ZTP script upgrade finished with failure status.

ZTP state field values for reboot: · REBOOTING--ZTP is rebooting the system. · REBOOTED--ZTP is finished rebooting the system.

ZTP state field values for configuration commit:
· CONFIG_COMMIT_SUCCEEDED--ZTP succeeded in committing user configuration.
· CONFIG_COMMIT_FAILED--ZTP user configuration commit failed.

ZTP state field values for finishing: · FAILED--ZTP failed. · SUCCEEDED--ZTP succeeded.

ZtpInterface

Name of interface.

FtpIpAddr

IP address.

860

Table 44: show system ztp Output Fields (Continued)

Field Name

Description

DefaultRouter

When the log server, NTP server, or FTP server are on a remote subnet, the value of DefaultRouter is used to configure a route to reach the servers.

LogServers

ZTP allows specification of a remote log server address. ZTP logs are then streamed to the remote log server.

NtpServers

ZTP allows specification of a remote NTP server address.

TransferMode

Options for TransferMode are ftp, tftp, http, or https

ImageFileType

It can be a symbolic link.

ConfigFileName

Configuration filename.

ConfigUrl

Configuration URL.

ConfigStatus

This field specifies whether the config file is downloading, is downloaded, or the download is being retried.

ZtpRetryCount

If the ZTP state machine, which applies the image and configuration, fails, the number of retries attempted.

DhcpRetryCount

If the DHCP state machine, which fetches parameters for ZTP from the DHCP server, fails, the number of times it retries.

ZTP State History

Lists the last 10 state transitions by Time (date and time) and Description or which state it was in then.

861
Sample Output

show system ztp

user@host> show system ztp

Attribute

Value

--------------------------

ZtpState

IMAGE_CONFIG_UPGRADING

ZtpInterface

vmb0

FtpIpAddr

10.10.213.1

HostName

sw-123

LogServers

[u'10.10.213.1']

NtpServers

[u'10.10.255.62', u'10.10.255.63']

TransferMode

tftp

ImageFileName

/ZTP_IMAGES/test.iso

ImageFileType

None

ImageUrl

tftp://17.17.213.1//ZTP_IMAGES/junos-evo-scapa.iso

ImageStatus

IMAGE_DOWNLOADED

ConfigFileName

/ZTP_CONFIG/sw-123.cfg

ConfigUrl

tftp://10.10.213.1//ZTP_CONFIG/sw-123.cfg

ConfigStatus

CONFIG_DOWNLOADED

ZtpRetryCount

0

DhcpRetryCount

0

ZTP State History(last 10 transitions)

Time

Description

Fri Jun 5 22:35:40 2020 Started

Fri Jun 5 22:36:46 2020 Initialized

Fri Jun 5 22:37:08 2020 Discovering interfaces

Fri Jun 5 22:37:31 2020 Querying DHCP Server

Fri Jun 5 22:37:43 2020 DHCP query succeeded

Fri Jun 5 22:41:46 2020 Upgrading image and config

Release Information
Command introduced in Junos OS Evolved Release 19.1R1.

862
RELATED DOCUMENTATION Zero Touch Provisioning | 406
show version
IN THIS SECTION Syntax | 862 Syntax (EX Series Switches) | 863 Syntax (TX Matrix Router) | 863 Syntax (TX Matrix Plus Router) | 863 Syntax (MX Series Router) | 863 Syntax (QFX Series) | 864 Syntax (Junos OS Evolved) | 864 Description | 864 Options | 865 Additional Information | 866 Required Privilege Level | 867 Sample Output | 867 Release Information | 869
Syntax
show version <brief | detail>

863
Syntax (EX Series Switches)
show version <all-members> <brief | detail> <local> <member member-id>
Syntax (TX Matrix Router)
show version <brief | detail> <all-chassis | all-lcc | lcc number | scc>
Syntax (TX Matrix Plus Router)
show version <all-chassis | all-lcc | lcc number | sfc number> <brief | detail>
Syntax (MX Series Router)
show version <brief | detail> <all-members> <local> <member member-id>

864
Syntax (QFX Series)
show version <brief | detail> <component component-name | all>

Syntax (Junos OS Evolved)
show version <brief | detail> <node (all | node-name)>

Description
Display the hostname and version information about the software running on the router or switch.
Beginning in Junos OS Release 13.3, the show version command output includes the Junos field that displays the Junos OS version running on the device. This field provides a consistent means of identifying the Junos OS version, rather than extracting that information from the list of installed subpackages.
The output for the show version command for Junos OS Evolved includes a Junos Package field that indicates the installation package name. From the prefix of this package name, you can decode which Junos OS architecture the device is running. Table 45: Common Package Prefixes for Junos OS
Junos OS Package Prefix Junos OS Architecture

jinstall-*

Junos OS for M Series, MX Series, T Series, TX Matrix, and TX Matrix Plus routers

junos-install-*

Junos OS based on an upgraded FreeBSD kernel instead of older versions of FreeBSD

865

Table 45: Common Package Prefixes for Junos OS (Continued) Junos OS Package Prefix Junos OS Architecture

junos-vmhost-install-* Junos OS with upgraded FreeBSD on a VM Host

junos-evo-install-*

Junos OS Evolved

Options

none brief | detail all-members
component all component componentname
local
member member-id

Display standard information about the hostname and version of the software running on the router or switch.
(Optional) Display the specified level of output.
(EX4200 switches and MX Series routers only) (Optional) Display standard information about the hostname and version of the software running on all members of the Virtual Chassis configuration.
(QFabric systems only) (Optional) Display the host name and version information about the software running on all the components on the QFabric system.
(QFabric systems only) (Optional) Display the host name and version information about the software running on a specific QFabric system component. Replace component-name with the name of the QFabric system component. The componentname can be the name of a diagnostics Routing Engine, Director group, fabric control Routing Engine, fabric manager Routing Engine, Interconnect device, or Node group.
(EX4200 switches and MX Series routers only) (Optional) Display standard information about the hostname and version of the software running on the local Virtual Chassis member.
(EX4200 switches and MX Series routers only) (Optional) Display standard information about the hostname and version of the software running on the specified member of the Virtual Chassis configuration. For EX4200 switches, replace memberid with a value from 0 through 9. For an MX Series Virtual Chassis, replace memberid with a value of 0 or 1.

866

node (all | nodename) scc

(Optional) Display version information for the specified node or all nodes.
(TX Matrix routers only) (Optional) Display the hostname and version information about the software running on the TX Matrix router (or switch-card chassis).

lcc number

(TX Matrix routers and TX Matrix Plus routers only) (Optional) On a TX Matrix router, display the host name and version information about the software running on for a specified T640 router (line-card chassis or LCC) that is connected to the TX Matrix router. On a TX Matrix Plus router, display the host name and version information about the software running for a specified T1600 or T4000 router (LCC) that is connected to the TX Matrix Plus router.
Replace number with the following values depending on the LCC configuration:

· 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

· 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

· 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

· 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

sfc number

(TX Matrix Plus routers only) (Optional) Display the hostname and version information about the software running on the TX Matrix Plus router (or switchfabric chassis). Replace number with 0.

Additional Information
By default, when you issue the show version command on a TX Matrix or TX Matrix Plus primary Routing Engine, the command is broadcast to all the T640 (in a routing matrix based on a TX Matrix router) or T1600 or T4000 (in a routing matrix based on a TX Matrix Plus router) primary Routing Engines connected to it. Likewise, if you issue the same command on the TX Matrix or TX Matrix Plus backup Routing Engine, the command is broadcast to all the T640 (in a routing matrix based on a TX Matrix router) or T1600 or T4000 (in a routing matrix based on a TX Matrix Plus router) backup Routing Engines that are connected to it.

867
Required Privilege Level
view
Sample Output
show version (Devices Running Junos OS Release 13.3 and Later)
The following output is from the MX240 Router and shows the Junos field introduced in Junos OS 13.3. Depending on the platform running Junos OS 13.3, you might see different installed sub-packages, but the Junos field is common across all platforms that run Junos OS 13.3 and later.
user@host > show version Hostname: lab Model: mx240 Junos: 13.3R1.4 JUNOS Base OS boot [13.3R1.4] JUNOS Base OS Software Suite [13.3R1.4] JUNOS Kernel Software Suite [13.3R1.4] JUNOS Crypto Software Suite [13.3R1.4] JUNOS Packet Forwarding Engine Support (M/T/EX Common) [13.3R1.4] JUNOS Packet Forwarding Engine Support (MX Common) [13.3R1.4] JUNOS Online Documentation [113.3R1.4] JUNOS Services AACL Container package [13.3R1.4] JUNOS Services Application Level Gateways [13.3R1.4] JUNOS AppId Services [13.3R1.4] JUNOS Border Gateway Function package [13.3R1.4] JUNOS Services Captive Portal and Content Delivery Container package [13.3R1.4] JUNOS Services HTTP Content Management package [13.3R1.4] JUNOS IDP Services [13.3R1.4] JUNOS Services Jflow Container package [13.3R1.4] JUNOS Services LL-PDF Container package [13.3R1.4] JUNOS Services MobileNext Software package [13.3R1.4] JUNOS Services Mobile Subscriber Service Container package [13.3R1.4] JUNOS Services NAT [13.3R1.4] JUNOS Services PTSP Container package [13.3R1.4] JUNOS Services RPM [13.3R1.4] JUNOS Services Stateful Firewall [13.3R1.4] JUNOS Voice Services Container package [13.3R1.4]

868
JUNOS Services Crypto [13.3R1.4] JUNOS Services SSL [13.3R1.4] JUNOS Services IPSec [13.3R1.4] JUNOS platform Software Suite [13.3R1.4] JUNOS Runtime Software Suite [13.3R1.4] JUNOS Routing Software Suite [13.3R1.4] JUNOS py-base-i386 [13.3R1.4]
show version
user@host> show version Hostname: router1 Model: m20 JUNOS Base OS boot [7.2-20050312.0] JUNOS Base OS Software Suite [7.2-20050312.0] JUNOS Kernel Software Suite [7.2R1.7] JUNOS Packet Forwarding Engine Support (M20/M40) [7.2R1.7] JUNOS Routing Software Suite [7.2R1.7] JUNOS Online Documentation [7.2R1.7] JUNOS Crypto Software Suite [7.2R1.7]
command-name
{master} user@host> show version psd 1 psd1-re0: -------------------------------------------------------------------------Hostname: china Model: t640 JUNOS Base OS boot [9.1I20080311_1959_builder] JUNOS Base OS Software Suite [9.1-20080321.0] JUNOS Kernel Software Suite [9.1-20080321.0] JUNOS Crypto Software Suite [9.1-20080321.0] JUNOS Packet Forwarding Engine Support (M/T Common) [9.1-20080321.0] JUNOS Packet Forwarding Engine Support (T-series) [9.1-20080321.0] JUNOS Online Documentation [9.1-20080321.0] JUNOS Routing Software Suite [9.1-20080321.0] labpkg [7.0]

869
show version (Junos OS Evolved with third-party application installed)
user@host> show version Model: ptx10003-160c Junos: 20.1-201910240713.0-EVO Junos Package: junos-evo-install-ptx-fixed-x86-64-20.1-201910240713.0-EVO.iso Yocto: 2.2.1 Linux Kernel: 4.8.28-WR2.2.1_standard-g21fb4b9 SDK version: 5.6.7 External Software:
acmeMonitor-1.2.3 [sdk 5.6.7] acmeLoadShare-3.4.5 [sdk 5.6.8]
Release Information
Command introduced before Junos OS Release 7.4. sfc option introduced for the TX Matrix Plus router in Junos OS Release 9.6. node option introduced in Junos OS Evolved Release 18.3R1.

14 CHAPTER
VM Host Administration Commands
request vmhost cleanup | 871 request vmhost copy jnode-to-vjunos | 873 request vmhost copy vjunos-to-jnode | 874 request vmhost file-copy | 876 request vmhost halt | 878 request vmhost hard-disk-test | 880 request vmhost power-off | 883 request vmhost power-on | 885 request vmhost reboot | 887 request vmhost snapshot | 889 request vmhost software abort in-service-upgrade | 893 request vmhost software add | 894 request vmhost software in-service-upgrade | 899 request vmhost software rollback | 905 request vmhost software validate | 909 request vmhost zeroize | 910

871
request vmhost cleanup
IN THIS SECTION Syntax | 871 Description | 871 Options | 871 Required Privilege Level | 872 Output Fields | 872 Release Information | 873
Syntax
request vmhost cleanup <invoke-on> <re0 | re1> <routing engine>
Description
Clean up temporary files, crash generated files, and log files located in the /var/tmp, /var/crash, and /var/log directories respectively on the host OS.
Options
none--Clean up temporary files, crash generated files, and log files located in the /var/tmp, /var/crash, and /var/log directories on the host OS running on the Routing Engine on the local Virtual Chassis member.

872

invokeon

(Optional) Clean up temporary files, crash generated files, and log files on all the Routing Engines or the other Routing Engine.

Clean up files in /var/tmp, /var/crash, and /var/log on the host OS running on a router that has dual Routing Engines. You can use the all-routing-engine option to clean up the files in these directories on the host OS running on all the Routing Engines or the other-routingengine option to clean up the files in these directories on the host OS running on the other Routing Engine. If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, clean up files in /var/ tmp, /var/crash, and /var/log on the host OS running on the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

routingengine

(Optional) Specify the Routing Engine for which the files in /var/tmp, /var/crash, and /var/log on the host OS are to be cleaned up. The following options are available:

· backup--Backup Routing Engine.

· both--Primary and backup Routing Engines.

· local--Routing Engine on the local Virtual Chassis member.

· master--Primary Routing Engine.

· other--If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.

873
Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION request system storage cleanup | 754
request vmhost copy jnode-to-vjunos
IN THIS SECTION Syntax | 873 Description | 874 Options | 874 Required Privilege Level | 874 Release Information | 874
Syntax
request vmhost copy jnode-to-vjunos from-jnode host-filename to-vjunos junosfilename

874
Description
Copy files from Linux host to Junos OS.

Options
from-jnode host-filename to-vjunos junos-filename

Name of the host file to be copied. Name of the Junos OS file to which the host file is copied.

Required Privilege Level
maintenance
Release Information
Command introduced in Junos OS Release 18.4R1 on Enhanced Automation variants of Junos OS. For more information, see Overview of Junos Automation Enhancements on Devices Running Junos OS with Enhanced Automation.
RELATED DOCUMENTATION request vmhost copy vjunos-to-jnode | 874
request vmhost copy vjunos-to-jnode

IN THIS SECTION Syntax | 875

875
Description | 875 Options | 875 Required Privilege Level | 875 Release Information | 876

Syntax
request vmhost copy vjunos-to-jnode from-vjunos junos-filename to-jnode hostfilename

Description
Copy files from Junos OS to Linux host.

Options
from-vjunos junos-filename to-jnode host-filename

Name of the Junos OS file to be copied. Name of the host file to which to copy the file.

Required Privilege Level
maintenance

876
Release Information
Command introduced in Junos OS Release 18.4R1 on Enhanced Automation variants of Junos OS. For more information, see Overview of Junos Automation Enhancements on Devices Running Junos OS with Enhanced Automation.
RELATED DOCUMENTATION request vmhost copy jnode-to-vjunos | 873
request vmhost file-copy
IN THIS SECTION Syntax | 876 Description | 877 Options | 877 Additional Information | 877 Required Privilege Level | 877 Sample Output | 877 Release Information | 878
Syntax
request vmhost file-copy (crash|log) j-node host file-name v-junos host file-name

877
Description
Copy crash files or log files from the host OS to Junos OS. You can use these files for analysis and debugging purposes.

Options
crash from j-node filename log to v-junos filename

Files in /var/crash on the host. Name of the host file to be copied. Files in /var/log on the host. Name of the Junos OS file to which the host file is copied.

Additional Information
You can use the show vmhost crash and show vmhost logs commands to list or identify the files in the host OS to be copied to Junos OS.
Required Privilege Level
maintenance
Sample Output
request vmhost file-copy
user@host> request vmhost file-copy log from-jnode debug-20160214 to-vjunos /var/tmp/ /var/home/<user> # cd /var/tmp :/var/tmp # ls -lrt debug-20160214

878
.... root@host:/var/tmp #
Release Information
Command introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
Command introduced in Junos OS Release 18.1R1 for NFX150 devices. Command introduced in Junos OS Release 18.4R1 for NFX250 (NG) devices. Command introduced in Junos OS Release 19.1R1 for NFX350 devices.
request vmhost halt
IN THIS SECTION Syntax | 879 Description | 879 Options | 879 Required Privilege Level | 880 Sample Output | 880 Release Information | 880

879
Syntax
request vmhost halt <re0 | re1> <routing-engine>

Description
Stop the host OS and Junos OS running on the device.

Options

none--Stop the host OS and Junos OS on the device.

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, stop the host OS and Junos OS running on the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine on which the host OS and Junos OS needs to be stopped. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

880
Required Privilege Level
maintenance
Sample Output
request vmhost halt
request vmhost halt
Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION request system halt vmhost | 578
request vmhost hard-disk-test
IN THIS SECTION Syntax | 881 Description | 881 Options | 881

881
Required Privilege Level | 881 Sample Output | 882 Release Information | 883

Syntax
request vmhost hard-disk-test {disk disk-name|long|short|show-status}

Description
Run memory and diagnostics monitoring test on the solid-state drive (SSD). The test output provides information about the various attributes of the SSD that is help monitor the status of the hard disk memory.

Options

disk disk-name Name of the SSD.

long

Run extended Self-Monitoring, Analysis and Reporting Technology (SMART) tests of

the SSD.

short

Run short SMART tests of the SSD.

show-status Display the status of the test.

Required Privilege Level
maintenance

882

Sample Output
request vmhost hard-disk-test

user@host> request vmhost hard-disk-test show-status disk /dev/sda smartctl 5.42 2014-07-28 r3460 [x86_64-linux-3.10.79-ovp-rt74-WR6.0.0.20_preemptrt] (local build)Copyright (C) 2002-11 by Bruce Allen, http:// smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===

Model Family:

StorFly Slim Sata SSD

Device Model:

StorFly VSF202CC050G-JUN

Serial Number: P1T13003443810130041

Firmware Version: 0729-000

User Capacity: 50,020,540,416 bytes [50.0 GB]

Sector Size:

512 bytes logical/physical

Device is:

In smartctl database [for details use: -P show]

ATA Version is: 8

ATA Standard is: ACS-2 (revision not indicated)

Local Time is: Fri Jun 17 17:30:57 2016 IST

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

=== START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED

General SMART Values: Offline data collection status:
Self-test execution status:

(0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled.
( 0) The previous self-test routine completed without error or no self-test has ever been run.

... ... ...

883
Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION vmhost | 578
request vmhost power-off
IN THIS SECTION Syntax | 883 Description | 884 Options | 884 Required Privilege Level | 884 Sample Output | 884 Release Information | 884
Syntax
request vmhost power-off <other routing-engine>

884
Description
Power off the Routing Engine on which Junos OS and the host OS are running. In a PTX3000, the Routing and Control Board is powered off.
NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

Options

none--Power off the Routing Engine immediately.

otherroutingengine

(Optional) Power off the other Routing Engine on which the Junos OS and the host OS are running. For example, if you issue the command from the primary Routing Engine, the backup Routing Engine is powered off. Similarly, if you issue the command from the backup Routing Engine, the primary Routing Engine is powered off.

Required Privilege Level
maintenance
Sample Output
request vmhost power-off
request vmhost power-off

Release Information
Command introduced in Junos OS Release 15.1F3.

885
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION request system power-off vmhost | 578
request vmhost power-on
IN THIS SECTION Syntax | 885 Description | 885 Options | 886 Required Privilege Level | 886 Sample Output | 886 Release Information | 886
Syntax
request vmhost power-on other-routing-engine
Description
Power on the Routing Engine on which Junos OS and the host OS are running. In a PTX3000, the Routing and Control Board is powered on.

886

Options

otherroutingengine

Power on the other Routing Engine on which the Junos OS and the host OS are running. For example, if you issue the command from the primary Routing Engine, the backup Routing Engine is powered on. Similarly, if you issue the command from the backup Routing Engine, the primary Routing Engine is powered on.

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

Required Privilege Level
maintenance
Sample Output
request vmhost power-on
user@host> request vmhost power-on other-routing-engine Routing Engine 1 power-on initiated, use "show chassis routing-engine" to verify
Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

887
RELATED DOCUMENTATION request vmhost power-off | 883 request vmhost reboot | 887
request vmhost reboot
IN THIS SECTION Syntax | 887 Description | 887 Options | 888 Required Privilege Level | 888 Sample Output | 889 Release Information | 889
Syntax
request vmhost reboot <disk1> <disk2> <network> <re0 | re1> <routing engine> <usb>
Description
Reboot both the Junos OS and the host OS running on the device.

888

Options

none--Reboot the device software immediately.

disk1

(Optional) Reboot both Junos OS and the host OS on the Routing Engine and boot the Routing Engine from the primary disk.

disk2

(Optional) Reboot both Junos OS and the host OS on the Routing Engine and boot the Routing Engine from backup disk.

network

(Optional) Reboot both Junos OS and the host OS on the Routing Engine and boot the Routing Engine from network by using the PXE boot method.

re0 | re1

(Optional) On routers that support dual or redundant Routing Engines, reboot both Junos OS and the host OS on the Routing Engine in slot 0 (re0) or on the the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine on which Junos OS and the host OS are to be rebooted. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine.

· both--Both Routing Engines.

· local--Routing Engine on the local Virtual Chassis member.

· master--Primary Routing Engine.

· other--If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

usb

(Optional) Reboot both Junos OS and the host OS on the Routing Engine using the USB

installation media.

Required Privilege Level
maintenance

889
Sample Output
request vmhost reboot
request vmhost reboot <disk1> <disk2> <in> <network> <usb>
Release Information
Command introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION request system reboot | 632 request vmhost power-on | 885
request vmhost snapshot
IN THIS SECTION Syntax | 890 Description | 890 Options | 890

890
Required Privilege Level | 891 Sample Output | 891 Release Information | 892

Syntax
request vmhost snapshot <partition> <re0 | re1> <recovery> <routing-engine>

Description
Create a recovery snapshot of the currently running and active file system partitions on the backup disk to recover the primary disk in case of failure.
On the device, back up the snapshot of the host OS image along with the Junos OS image. In case of failure of the primary disk, you can boot from the image available in the backup disk and then recover the primary disk with the snapshot created using the recovery option.

Options

none--Create a snapshot from the current disk to the target disk without partitioning the target disk. Contents on target disk is lost.

partition

(Optional) Create a snapshot from the current disk to target disk and partition the target disk. Contents on the target disk are lost

re0 | re1

(Optional) Create a snapshot from the current disk to target disk and partition the target disk on Routing Engine in slot 0 (re0) or on the Routing Engine in slot 1 (re1). The snapshot is taken without partitioning the target disk on corresponding Routing Engines. Contents on the target disk on the Routing Engines are lost.

891

For PTX1000 routers, since there is only one RE, re0|re1 is not supported.
NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

recovery routingengine

(Optional) Recover the primary disk from the snapshot content stored in the backup disk. This option is applicable only when the Routing engine is booted from backup disk. Contents in the primary disk are lost.
(Optional) Specify the Routing Engine on which the snapshot is to be created. The following options are available: · backup--Backup Routing Engine.
· both--Both Routing Engines.
· local--Routing Engine on the local Virtual Chassis member.
· master--Primary Routing Engine.
· other--Other Routing Engine.

Required Privilege Level
maintenance

Sample Output
request vmhost snapshot

user@host> request vmhost snapshot warning: Existing data on the target may be lost Proceed ? [yes,no] (no) yes

warning: Proceeding with vmhost snapshot

Current root details,

Device sda, Label: jrootb_P, Partition: sda4

Snapshot admin context from current boot disk to target disk ...

892

Proceeding with snapshot on secondary disk Mounting device in preparation for snapshot... Cleaning up target disk for snapshot ... Creating snapshot on target disk from current boot disk ... Snapshot created on secondary disk. Software snapshot done

request vmhost snapshot recovery

user@host> request vmhost snapshot recovery warning: Existing data on the target may be lost Proceed ? [yes,no] (no) yes

warning: Proceeding with vmhost snapshot

Current root details,

Device sdb, Label: jrootb_S, Partition: sdb4

Snapshot admin context from current boot disk to target disk ...

Proceeding with snapshot on primary disk

Mounting device in preparation for snapshot...

Cleaning up target disk for snapshot ...

Creating snapshot on target disk from current boot disk ...

Primary disk is recovered now. Please issue "request vmhost reboot" to boot from

the primary disk.

Software snapshot done

Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

RELATED DOCUMENTATION show vmhost snapshot | 941

893
request vmhost software abort in-service-upgrade
IN THIS SECTION Syntax | 893 Description | 893 Options | 893 Required Privilege Level | 894 Release Information | 894
Syntax
request vmhost software abort in-service-upgrade

Description
Terminate unified in-service software upgrade (unified ISSU). The unified ISSU must be in progress and you must issue this command from a router session other than the one on which you issued the request vmhost software in-service-upgrade command to launch the unified ISSU.

Options
in-service-upgrade

Terminate unified ISSU.

894
Required Privilege Level
maintenance
Release Information
Command introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION request system software abort request vmhost software in-service-upgrade | 899
request vmhost software add
IN THIS SECTION MX Series | 895 PTX Series | 895 Description | 895 Options | 896 Additional Information | 897 Required Privilege Level | 898 Sample Output | 898 Release Information | 898

895
MX Series
request vmhost software add package-name <no-validate> <re0 | re1> <reboot> <set [package-names]>
PTX Series
request vmhost software add package-name <in> <log_collector.sh> <no-validate> <reboot> <set [package-names]> <unlink> <upgrade-to-model>
Description
Install Junos OS and host software packages on the device. For installing the host software as well as Junos OS, specify the package name junos-vmhost-installx.tgz in the request vmhost software add command. Junos OS installation alone can be achieved by specifying the regular package name junos-install-x.tgz in the request system software add command. However, installation using the vmhost package is recommended as it upgrades both the host software and Junos OS.
NOTE: You must load the PTX1000, PTX10008, PTX10016, PTX10002-60C, and QFX10002-60C devices only with junos-vmhost-install-x.tgz package using the request vmhost software add command. The junos-vmhost-install-x.tgz package upgrades both the host software and Junos OS. The PTX1000, PTX10008, PTX10016, PTX10002-60C, and QFX10002-60C devices do not support Junos only upgrade. If you try to load Junos only image,

896
then these devices go down or vmhost commands do not work or the device state is unpredictable.

Options

none--Install Junos OS and host software packages on the Routing Engine on the local Virtual Chassis member.

packagename

Location from which the software package or bundle is to be installed. For example:
· /var/tmp/package-name--For a software package or bundle that is being installed from a local directory on the device.

· protocol://hostname/pathname/package-name--For a software package or bundle that is to be downloaded and installed from a remote location. Replace protocol with one of the following:

· ftp--File Transfer Protocol (FTP).

Use ftp://hostname/pathname/package-name. To specify authentication credentials, use ftp://<username>:<password>@hostname/pathname/packagename. To have the system prompt you for the password, specify prompt in place of the password. If a password is required, and you do not specify the password or prompt, an error message is displayed.
· http--Hypertext Transfer Protocol (HTTP).

Use http://hostname/pathname/package-name. To specify authentication credentials, use http://<username>:<password>@hostname/pathname/ package-name. If a password is required and you omit it, you are prompted for it.
· scp--Secure Copy Protcol (SCP)(not available for limited editions).

Use scp://hostname/pathname/package-name. To specify authentication credentials, use scp://<username>:<password>@hostname/pathname/packagename.

NOTE:

897

· The pathname in the protocol is the relative path to the user's home directory on the remote system and not the root directory.
· Do not use the scp protocol in the request vmhost software add command to download and install a software package or bundle from a remote location. The software upgrade is handled by the mgd process that does not support SCP.
To install a software package or bundle from a remote location: 1. Use the file copy command to copy the software package or bundle from
the remote location to the /var/tmp directory on the hard disk:
file copy scp://source/package-name /var/tmp
2. Install the software package or bundle by using the request vmhost software add command:
request vmhost software add /var/tmp/package-name

no-validate re0 | re1

(Optional) When loading a software package or bundle with a different release, suppress the default behavior of the validate option.
(Optional) Load a software package or bundle on the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

NOTE: The option re1 is not supported on the PTX1000 Packet Transport Router.

reboot

(Optional) After adding the software package or bundle, reboot the system.

set [package- (Optional) names]

Additional Information
Before upgrading the software on the device, when you have a known stable system, issue the request vmhost snapshot command to back up the software. After you have upgraded the software on the

898
device and are satisfied that the new package or bundle is successfully installed and running, issue the request vmhost snapshot command again to back up the new software to the backup disk.
After you run the request vmhost snapshot command, you cannot return to the previous version of the snapshot, because the previous snapshot is replaced by the new snapshot.
Before installing software on a device that has one or more custom YANG data models added to it, back up and remove the configuration data corresponding to the custom YANG data models from the active configuration. For more information see "Managing YANG Packages and Configurations During a Software Upgrade or Downgrade" on page 118.

Required Privilege Level
maintenance

Sample Output
request vmhost software add (Multiple Packages)

request vmhost <no-validate> <re0 | re1> <reboot>

software add package-name

Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

RELATED DOCUMENTATION request system software add | 679

899
request vmhost software rollback | 905
request vmhost software in-service-upgrade
IN THIS SECTION Syntax | 899 Description | 899 Options | 900 Additional Information | 901 Required Privilege Level | 901 Sample Output | 901 Sample Output | 902 Release Information | 904
Syntax
request vmhost software in-service-upgrade package-name < no-old-master-upgrade> < reboot> < verbose>
Description
Perform a unified in-service software upgrade (ISSU). A unified ISSU enables you to upgrade from one Junos OS release and host OS release to another with no disruption on the control plane and with minimal disruption of traffic. For an unified ISSU, graceful Routing Engine switchover (GRES) and nonstop active routing (NSR) must be enabled.

900
Starting inJunos OS Release 18.2R1, MX10003 routers support unified in-service software upgrade (ISSU) using request vmhost software in-service-upgrade command. MX10003 does not support upgrading Junos OS only image using request system software in-service-upgrade command.
NOTE: On MX10003 routers: · ISSU is not supported on MACsec MIC (JNP-MIC1-MACSEC).
· ISSU is not supported for the interfaces that are configured with 1-Gigabit Ethernet mode. If ISSU upgrade is carried out in 1-Gigabit Ethernet mode, then the behavior is unexpected and traffic loss can be expected.
· ISSU is not supported on timing protocols (like, Precision Time Protocol and Synchronous Ethernet), MACsec protocols, and BBE protocols. If these protocols are already enabled, then it will not work after ISSU is enabled.
· The MAC statistics (retrieved using show interfaces extensive command) are reset during ISSU which means that the MAC statistics does not provide the correct statistics after ISSU.

Options

packagename no-oldmasterupgrade

Location from which the software package or bundle is to be installed. For example:
· /var/tmp/package-name-- For a software package or bundle that is being installed from a local directory on the router.
· protocol://hostname/pathname/package-name--For a software package or bundle that is to be downloaded and installed from a remote location. Replace protocol with one of the following:
· ftp--File Transfer Protocol (FTP).
· http--Hypertext Transfer Protocol (HTTP).
· scp--Secure Copy Protocol (SCP) (not available for limited editions).
(Optional) When the no-old-master-upgrade option is included, after the backup Routing Engine is rebooted with the new software package and a switchover occurs to make it the new primary Routing Engine, the former primary (new backup) Routing Engine is not upgraded to the new software. In this case, you must manually upgrade the former primary (new backup) Routing Engine. If you do not include the no-old-master-upgrade option, the system automatically upgrades the former primary Routing Engine.

901

reboot verbose

(Optional) Automatically reboot the former primary (new backup) Routing Engine after the ISSU. If you don not include the reboot option in the command, you must manually reboot the former primary (new backup) Routing Engine by using the request vmhost reboot command.
(Optional) (MX Series) Use this option to display the daemon related information during the upgrade.

Additional Information
The following conditions apply to unified ISSU: · Unified ISSU is not supported on every platform. For a list of supported platforms, see Unified ISSU
System Requirements. · Unsupported PICs are restarted during a unified ISSU on certain routing devices. · During a unified ISSU, any unsupported protocols running on the device causes packet loss. · During a unified ISSU, you cannot bring any PICs online or take them offline on certain routing
devices.
Required Privilege Level
maintenance
Sample Output
request vmhost software in-service-upgrade
user@host> request vmhost software in-service-upgrade /var/tmp/junos-vmhost-install-ptx-x86-64-15.1F5.6.tgz reboot Chassis ISSU Check Done [Feb 24 01:12:09]: Starting VMHOST ISSU [Feb 24 01:12:09]:ISSU: Validating Image FPC 2 will be offlined (In-Service-Upgrade not supported)

902
FPC 11 will be offlined (In-Service-Upgrade not supported) MIC 11/0 will be offlined (In-Service-Upgrade not supported) Do you want to continue with these actions being taken ? [yes,no] (no) yes Junos Validation begin. Procedure will take few minutes.
... ...
Sample Output
request vmhost software in-service-upgrade verbose
user@host> request vmhost software in-service-upgrade verbose
... ... Oct 26 15:20:02 [INFO ] Verified py-extensions signed by PackageDevelopmentEc_2017 method ECDSA256+SHA256 Oct 26 15:20:02 [INFO ] Adding py-extensionsx86-32-20171024.002108_builder_release_174_throttle ... Oct 26 15:20:02 [INFO ] Verified vrr-mx signed by PackageDevelopmentEc_2017 method ECDSA256+SHA256 Oct 26 15:20:02 [INFO ] NOTICE: 'pending' set will be activated at next reboot... Oct 26 15:20:02 [INFO ] [Oct 26 02:36:10]:ISSU: Installing package /var/tmp/ junos-install-mx-x86-64-17.4-20171024.0.tgz on re1 done Oct 26 15:20:02 [INFO ] [Oct 26 02:36:10]:ISSU: Rebooting Backup RE Oct 26 15:20:02 [INFO ] Oct 26 15:20:02 [INFO ] Rebooting re1 Oct 26 15:20:02 [INFO ] [Oct 26 02:36:11]:ISSU: Backup RE Prepare Done Oct 26 15:20:02 [INFO ] [Oct 26 02:36:11]:ISSU: Waiting for Backup RE reboot Oct 26 15:20:02 [INFO ] [Oct 26 02:39:26]:ISSU: Backup RE reboot done. Backup RE is up Oct 26 15:20:02 [INFO ] [Oct 26 02:39:26]:ISSU: Waiting for Backup RE state synchronization Oct 26 15:20:02 [INFO ] [Oct 26 02:39:51]:ISSU: Backup RE state synchronization done Oct 26 15:20:02 [INFO ] [Oct 26 02:39:51]:ISSU: GRES operational Oct 26 15:20:02 [INFO ] [Oct 26 02:40:52]: "Initiating Chassis In-ServiceUpgrade"

903
Oct 26 15:20:02 [INFO ] Chassis ISSU Started Oct 26 15:20:02 [INFO ] [Oct 26 02:40:57]:ISSU: Preparing Daemons Oct 26 15:20:02 [INFO ] [Oct 26 02:40:57]: Daemon [rpd] transitioned to READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:40:57]: Daemon [lfmd] transitioned to READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:40:57]: Daemon [l2cpd] transitioned to READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:40:57]: Daemon [smid] transitioned to READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:40:57]: Daemon [bfdd] transitioned to READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:41:17]:ISSU: Daemons Ready for ISSU Oct 26 15:20:02 [INFO ] [Oct 26 02:41:17]: Daemon [apsd] transitioned to READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:41:22]:ISSU: Offline Incompatible FRUs Oct 26 15:20:02 [INFO ] [Oct 26 02:41:27]:ISSU: Starting Upgrade for FRUs Oct 26 15:20:02 [INFO ] [Oct 26 02:41:27]: [FPC 1] None -> Prepare Oct 26 15:20:02 [INFO ] [Oct 26 02:41:48]: [FPC 1] Prepare -> Ready for Reboot Oct 26 15:20:02 [INFO ] [Oct 26 02:41:52]: [FPC 1] Ready for Reboot -> Reboot Oct 26 15:20:02 [INFO ] [Oct 26 02:42:01]: [FPC 1] Reboot -> Blob Resync Oct 26 15:20:02 [INFO ] [Oct 26 02:42:28]: [FPC 1] Blob Resync -> Ready Software State Sync Oct 26 15:20:02 [INFO ] [Oct 26 02:42:32]: [FPC 1] Ready Software State Sync -> Software State Sync Oct 26 15:20:02 [INFO ] [Oct 26 02:44:02]: [FPC 1] Software State Sync -> Ready Hardware State Sync Oct 26 15:20:02 [INFO ] [Oct 26 02:44:02]: [FPC 1] Ready Hardware State Sync -> Hardware State Sync Oct 26 15:20:02 [INFO ] [Oct 26 02:47:07]: [FPC 1] Hardware State Sync -> Reconnected Oct 26 15:20:02 [INFO ] [Oct 26 02:47:07]:ISSU: FRU Upgrade Done Oct 26 15:20:02 [INFO ] [Oct 26 02:47:07]:ISSU: Preparing for Switchover Oct 26 15:20:02 [INFO ] [Oct 26 02:47:07]: Daemon [lfmd] transitioned to SWITCHOVER_READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:47:07]: Daemon [rpd] transitioned to SWITCHOVER_READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:47:07]: Daemon [l2cpd] transitioned to SWITCHOVER_READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:47:07]: Daemon [smid] transitioned to SWITCHOVER_READY state Oct 26 15:20:02 [INFO ] [Oct 26 02:47:07]: Daemon [bfdd] transitioned to SWITCHOVER_READY state

904

Oct 26 15:20:02 [INFO ] [Oct 26 02:47:27]: Daemon [apsd] transitioned to

SWITCHOVER_READY state

Oct 26 15:20:02 [INFO ] [Oct 26 02:47:29]: Checking In-Service-Upgrade status

Oct 26 15:20:02 [INFO ] Item

Status

Reason

Oct 26 15:20:02 [INFO ] FPC 1

Online (ISSU)

Oct 26 15:20:02 [INFO ] Resolving mastership...

Oct 26 15:20:02 [INFO ] Complete. The other routing engine becomes the master.

Oct 26 15:20:02 [INFO ] [Oct 26 02:47:30]:ISSU: RE switchover Done

Oct 26 15:20:02 [INFO ] [Oct 26 02:47:30]:ISSU: Upgrading Old Master RE

Oct 26 15:20:02 [INFO ] Verified junos-install-mx-x86-64-17.4-20171024.0 signed

by PackageDevelopmentEc_2017 method ECDSA256+SHA256

Oct 26 15:20:02 [INFO ] Verified manifest signed by PackageDevelopmentEc_2017

method ECDSA256+SHA256

...

...

Release Information
Command introduced in Junos OS Release 15.1F3. Option introduced in Junos OS Release 18.2R1 for the MX Series routers.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION request system software in-service-upgrade

905
request vmhost software rollback
IN THIS SECTION Syntax | 905 Description | 905 Options | 905 Required Privilege Level | 906 Output Fields | 906 Sample Output | 906 Release Information | 908
Syntax
request vmhost software rollback <re0 | re1> <routing-engine>
Description
Roll back the Junos OS and the host OS software packages to the previous versions. You can revert to the previous versions of software packages that were loaded at the last successful request vmhost software add command.
Options
none--Roll back the software packages of the Routing Engine on the local Virtual Chassis member.

906

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, roll back the software packages in Routing Engine in slot 0 (re0) or software packages in the Routing Engine in slot 1 (re1).

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

routingengine

(Optional) Specify the Routing Engine on which the software packages needs to be rolled back to the previous set of software packages. The following options are available: · backup--Backup Routing Engine. · both--Both Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--Other Routing Engine.

Required Privilege Level
maintenance
Output Fields

Sample Output
request vmhost software rollback
request vmhost software rollback <reboot>

907

command-name

user@host> request vmhost software rollback

Current root details,

Device sda, Label: jrootp_P, Partition: sda3

Finding alternate root for rollback

Rollback to software on jrootb_P ...

sh /etc/install/mk-mtre-rollback.sh jrootb_P b

Mounting device in preparation for rollback...

Updating boot partition for rollback...

Rollback complete, please reboot the node for it to take effect.

Cmos Write successfull

Cmos Write successfull for Boot_retry

Cmos Write successfull for Boot_retry

command-name

user@host> show vmhost version

Current root details,

Device sda, Label: jrootp_P, Partition: sda3

Current boot disk: Primary

Current root set: p

UEFI

Version: NGRE_v00.53.00.01

Primary Disk, Upgrade Time: Wed Feb 24 17:51:53 UTC 2016 Pending reboot.

Version: set p VMHost Version: 2.951 VMHost Root: vmhost-x86_64-15.1I20160210_2212_builder VMHost Core: vmhost-core-x86_64-15.1I20160210_2212_builder kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt Junos Disk: junos-install-x86-64-15.1F5.5

Version: set b VMHost Version: 2.953 VMHost Root: vmhost-x86_64-15.1F520160222_1052_builder VMHost Core: vmhost-core-x86_64-15.1F520160222_1052_builder kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt Junos Disk: junos-install-x86-64-15.1F5.6

908
command-name
user@host> request vmhost reboot Reboot the vmhost ? [yes,no] (no) yes warning: Rebooting re1 Initiating vmhost reboot... ok Initiating Junos shutdown... shutdown: [pid 9733] Shutdown NOW! ok Junos shutdown is in progress... *** FINAL System shutdown message from root@nikon1 *** System going down IMMEDIATELY
Release Information
Command introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION request vmhost software add | 894 request vmhost software abort in-service-upgrade | 893

909
request vmhost software validate
IN THIS SECTION Syntax | 909 Description | 909 Required Privilege Level | 909 Sample Output | 910 Release Information | 910
Syntax
request vmhost software validate package-name
Description
Verify and validate the software package compatibility with the current configuration of the router.
Required Privilege Level
maintenance

910
Sample Output
request vmhost software validate
request vmhost software validate <package-name> <log_collector.sh>
Release Information
Statement introduced in Junos OS Release 18.4R1
NOTE: The command is supported on the routers with RE-MX-X6, RE-MX-X8, and RE-PTX-X8 Routing Engines with VM host support only.
RELATED DOCUMENTATION request system software abort request vmhost software in-service-upgrade | 899
request vmhost zeroize
IN THIS SECTION Syntax | 911 Description | 911 Options | 911 Required Privilege Level | 912 Sample Output | 912

911 Release Information | 913

Syntax
request vmhost zeroize <re0 | re1> <routing-engine>

Description
Remove all configuration information on the Routing Engines and reset all key values. If the device has dual Routing Engines, the command is broadcast to both Routing Engines on the device. The command removes all data files, including customized configuration and log files, by unlinking the files from their directories. The command removes all user-created files from the system including all plain-text passwords, secrets, and private keys for SSH, local encryption, local authentication, IPsec, RADIUS, TACACS+, and SNMP.
This command reboots the device and sets it to the factory-default configuration. After the reboot, you cannot access the device through the management Ethernet interface. Log in through the console as the root user and start the Junos OS CLI by typing cli at the prompt.

Options

none--Remove all configuration information on all the Routing Engines and reset all key values.

re0 | re1

(Optional) Remove all configuration information on the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

912

routingengine

(Optional) Remove all configuration information on the specified Routing Engine. The following options are available: · backup--Backup Routing Engine. · both--Both Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Master Routing Engine. · other--Other Routing Engine.

Required Privilege Level
maintenance
Sample Output
request vmhost zeroize
user@host> request vmhost zeroize VMHost Zeroization : Erase all data, including configuration and log files ? [yes,no] (no) yes
re0: -------------------------------------------------------------------------warning: Vmhost will reboot and may not boot without configuration warning: Proceeding with vmhost zeroize Zeroise secondary internal disk ... Proceeding with zeroize on secondary disk Mounting device in preparation for zeroize... Cleaning up target disk for zeroize ... Zeroize done on target disk. Zeroize of secondary disk completed Zeroize primary internal disk ... Proceeding with zeroize on primary disk Mounting device in preparation for zeroize...

913
Cleaning up target disk for zeroize ... Zeroize done on target disk. Zeroize of primary disk completed Zeroize done mv: cannot stat '/tmp/zero-UytUWY/tgt_jlvmrootfs/etc/fstab': No such file or directory mv: cannot stat '/tmp/zero-UytUWY/fstab': No such file or directory mv: cannot stat '/tmp/zero-6gvrWj/tgt_jlvmrootfs/etc/fstab': No such file or directory mv: cannot stat '/tmp/zero-6gvrWj/fstab': No such file or directory warning: Proceeding with vmhost reboot
*** FINAL System shutdown message from root@user ***
System going down IMMEDIATELY
Initiating vmhost reboot... ok Initiating Junos shutdown... shutdown: [pid 8565] Shutdown NOW! ok Junos shutdown is in progress... Shutdown NOW!
System shutdown time has arrived\x07\x07
re1: -------------------------------------------------------------------------warning: Vmhost will reboot and may not boot without configuration warning: Proceeding with vmhost zeroize Zeroise secondary internal disk ... Proceeding with zeroize on secondary disk
Release Information
Command introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

914
RELATED DOCUMENTATION request vmhost snapshot | 889

15 CHAPTER
VM Host Monitoring Commands
show vmhost bridge | 916 show vmhost crash | 918 show vmhost hard-disk-test | 920 show vmhost hardware | 922 show vmhost information | 925 show vmhost logs | 927 show vmhost management-if | 929 show vmhost netstat | 931 show vmhost processes | 934 show vmhost resource-usage | 937 show vmhost snapshot | 941 show vmhost status | 943 show vmhost uptime | 946 show vmhost version | 948

916
show vmhost bridge
IN THIS SECTION Syntax | 916 Syntax | 916 Description | 916 Options | 917 Required Privilege Level | 917 Sample Output | 917 Release Information | 918
Syntax
show vmhost bridge <invoke-on> <re0 | re1> <routing engine>
Syntax
Description
Display bridge table information. The bridge table provides information about the interfaces used for communication between host and guest operating systems.

917

Options

invoke-on

(Optional) Display the bridge table information of Routing Engines on a device that has dual or redundant Routing Engines. You can use the all-routing-engine option to display the bridge table information of all the Routing Engines or the other-routing-engine option to display the bridge table information of the other Routing Engine. For example, If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display bridge table information about the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

routingengine

(Optional) Specify the Routing Engine for which the bridge information is to be displayed. The following options are available: · backup--Backup Routing Engine.
· both--Primary and the backup Routing Engines.
· local-- Routing Engine on the local Virtual Chassis member.
· master--Primary Routing Engine.
· other--If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

Required Privilege Level
view
Sample Output

918

show vmhost bridge

user@host> show vmhost bridge

Compute cluster: rainier-re-cc

Compute node: rainier-re-cn

Bridge Table

============

bridge name

bridge id

jnpr-int-br

8000.bee5a8cfdb9a

virbr0

8000.52540051f94b

STP enabled no yes

interfaces tap1 virbr0-nic

Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

show vmhost crash

IN THIS SECTION
Syntax | 919 Description | 919 Required Privilege Level | 919 Sample Output | 919 Release Information | 919

919
Syntax
show vmhost crash
Description
Display the number of times the host OS crashed. The crash dumps are available at /var/crash.
Required Privilege Level
view
Sample Output
show vmhost crash
user@host> show vmhost crash Compute cluster: rainier-re-cc
Compute node: rainier-re-cn Crash Info ========== total 0
Release Information
Command introduced in Junos OS Release 15.1F3.

920
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION show system core-dumps
show vmhost hard-disk-test
IN THIS SECTION Syntax | 920 Description | 920 Options | 921 Required Privilege Level | 921 Sample Output | 921 Release Information | 922
Syntax
show vmhost hard-disk -test { disk disk-name | status}
Description
Display memory and diagnostics monitoring test status on the solid-state drive (SSD). The test output provides information about the various attributes of the SSD that help to monitor the status of the hard disk memory. This command should be used only after initiating the disk test with the request vmhost hard-disk-test command.

921

Options
disk disk-name status

Display the name of the SSD. Display the status of the test.

Required Privilege Level
maintenance

Sample Output
show vmhost hard-disk-test

user@host> show vmhost hard-disk-test status disk /dev/sda smartctl 5.42 2014-07-28 r3460 [x86_64-linux-3.10.79-ovp-rt74-WR6.0.0.20_preemptrt] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===

Model Family:

UNIGEN SATA SSD

Device Model:

SATA SSD

Serial Number: 3AF607410C3800117282

Firmware Version: S9FM01.3

User Capacity: 64,023,257,088 bytes [64.0 GB]

Sector Size:

512 bytes logical/physical

Device is:

In smartctl database [for details use: -P show]

ATA Version is: 8

ATA Standard is: ACS-3 (revision not indicated)

Local Time is: Sun Jan 8 08:02:22 2017 UTC

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

=== START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED

922

General SMART Values:

Offline data collection status: (0x00) Offline data collection activity

was never started.

Auto Offline Data Collection: Disabled.

Self-test execution status:

( 0) The previous self-test routine completed

without error or no self-test has ever

been run.

Total time to complete Offline

data collection:

( 30) seconds.

Offline data collection

capabilities:

(0x1b) SMART execute Offline immediate.

Auto Offline data collection on/off

support.

Suspend Offline collection upon new

...

...

...

Release Information
Command introduced in Junos OS Release 17.2R1.
RELATED DOCUMENTATION request vmhost hard-disk-test | 880
show vmhost hardware

IN THIS SECTION
Syntax | 923 Description | 923 Options | 923

923
Required Privilege Level | 924 Sample Output | 924 Release Information | 925

Syntax
show vmhost hardware <invoke-on> <re0 | re1> <routing engine>

Description
Display details of RAM and solid-state drives (SSDs) installed in the Routing Engine.

Options

none

(Optional) Display information about hardware.

invoke-on

(Optional) Display the details of RAM and solid-state drives (SSDs) installed on a device that has dual Routing Engines. You can use the all-routing-engine option to display the hardware information of all the Routing Engines or the other-routing-engine option to display the hardware information of the other Routing Engine. For example, if you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display hardware information about the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine for which the details of the installed RAM and solidstate drives (SSDs) is to be displayed. The following options are available:

924

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.
· backup--Backup Routing Engine. · both--Primary and backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other-- If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

Required Privilege Level
view

Sample Output

show vmhost hardware

user@host> show vmhost hardware Compute cluster: rainier-re-cc

Compute node: rainier-re-cn Hardware inventory:

Item DIMM 0 DIMM 1 DIMM 2 DIMM 3

Capacity 16384 MB 16384 MB 16384 MB 16384 MB

Part number 36ADS2G72PZ-2G1A1 36ADS2G72PZ-2G1A1 36ADS2G72PZ-2G1A1 36ADS2G72PZ-2G1A1

Serial number 0x0CF49320 0x0CF4934C 0x0CF49329 0x0CF49352

Description DDR4 2133 MHz DDR4 2133 MHz DDR4 2133 MHz DDR4 2133 MHz

925

Disk1 Disk2

50.0 GB StorFly-VSF202CC050G P1T13003443810130041 SLIM SATA SSD 50.0 GB StorFly-VSF202CC050G P1T13003443810130012 SLIM SATA SSD

Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

RELATED DOCUMENTATION show chassis hardware
show vmhost information

IN THIS SECTION
Syntax | 925 Description | 926 Options | 926 Required Privilege Level | 927 Sample Output | 927 Release Information | 927

Syntax
show vmhost information <invoke-on>

926
<re0 | re1> <routing engine>

Description
Display information about the host--such as IP address of the host Routing Engine, host OS version, model number or name of the Routing Engine, and so on.

Options

invoke-on

(Optional) Display information about the host on a device that has dual Routing Engines. You can use the all-routing-engine option to display information about the host of all the Routing Engines or the other-routing-engine option to display the information about the host of the other Routing Engine. If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine .

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display information about the host of Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine for which the information about the host is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and the backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

927
Required Privilege Level
view

Sample Output
show vmhost information

user@host> show vmhost information

Compute cluster: rainier-re-cc

Compute node

Model

Management IP

rainier-re-cn

RAINIER

x86_64 192.168.1.2/24

Kernel release

Machine

3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt

Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

show vmhost logs

IN THIS SECTION
Syntax | 928 Description | 928 Options | 928 Required Privilege Level | 929

928
Sample Output | 929 Release Information | 929

Syntax
show vmhost logs <re0 | re1> <routing engine>

Description
Display trace logs information of the host OS.

Options

re0 | re1 routingengine

(Optional) On devices that support dual or redundant Routing Engines, display trace logs information of the host os running on the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).
(Optional) Specify the Routing Engine for which the trace logs information of the host OS is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and the backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member.

929 · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.
Required Privilege Level
view
Sample Output
show vmhost logs
show vmhost logs
Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
show vmhost management-if
IN THIS SECTION Syntax | 930

930
Description | 930 Required Privilege Level | 930 Sample Output | 930 Release Information | 931
Syntax
show vmhost management-if
Description
Display the administrative status, speed and operational mode of the host interface eth0, which serves as a management interface.
Required Privilege Level
view
Sample Output
show vmhost management-if
user@host> show vmhost management-if Administrative status: Up Link status: Up Link speed: 1000Mb/s Link operational mode: Full

931
Release Information
Command introduced in Junos OS Release 15.1F6.
NOTE: The command is supported on the routers with RE-MX-X6, RE-MX-X8, and RE-PTX-X8 Routing Engines only.
show vmhost netstat
IN THIS SECTION Syntax | 931 Description | 932 Options | 932 Required Privilege Level | 933 Sample Output | 933 Release Information | 933
Syntax
show vmhost netstat <invoke-on> <re0 | re1> <routing engine>

932
Description
Display network statistics information for the host OS. The statistics contains information related to the interfaces used for the communication between the host and the guest, such as the IP address of the destination, IP address of the gateway, mask, flags, and so on.

Options

invoke-on

(Optional) Display the network statistics for the host OS on a device that has dual Routing Engines. You can use the all-routing-engine option to display the network statistics information for the host OS running on all the Routing Engines or the other-routing-engine option to display the network statistics information for the host OS running on the other Routing Engine. For example, If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine .

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display the network statistics information for the host OS running on the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine for which the network statistics information for the host OS is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and the backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

933
Required Privilege Level
view

Sample Output

show vmhost netstat

user@host> show vmhost netstat Compute cluster: rainier-re-cc

Compute node: rainier-re-cn

Netstat

=======

Kernel IP routing table

Destination

Gateway

0.0.0.0

10.216.63.254

10.216.48.0

0.0.0.0

192.168.1.0

0.0.0.0

int-br

192.168.122.0 0.0.0.0

virbr0

Genmask 0.0.0.0 255.255.240.0 255.255.255.0
255.255.255.0

Flags UG U U
U

MSS Window 0 0 0 0 0 0

irtt Iface 0 eth0 0 eth0 0 jnpr-

0 0

0

Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

934
show vmhost processes
IN THIS SECTION Syntax | 934 Description | 934 Options | 934 Required Privilege Level | 935 Sample Output | 935 Release Information | 937

Syntax
show vmhost processes <invoke-on> <re0 | re1> <routing engine>

Description
Display information about the host processes that are running on the device.

Options

invoke-on

(Optional) Display information about the host processes that are running on a device with dual Routing Engines. You can use the all-routing-engine option to display information about the host processes running on all the Routing Engines or the other-routing-engine option to display information about the host processes running on the other Routing

935

Engine. For example, If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine .

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display information about the host processes running on the Routing Engine in slot 0 (re0) or on the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine for which the information about the host processes is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and the backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

Required Privilege Level
view

Sample Output
show vmhost processes

user@host> show vmhost processes Compute cluster: rainier-re-cc

Compute node: rainier-re-cn

UID

PID PPID C STIME TTY

TIME CMD

936

root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root root

1

0 0 21:56 ?

2

0 0 21:56 ?

3

2 0 21:56 ?

5

2 0 21:56 ?

7

2 0 21:56 ?

8

2 0 21:56 ?

9

2 0 21:56 ?

10

2 0 21:56 ?

11

2 0 21:56 ?

12

2 0 21:56 ?

13

2 0 21:56 ?

14

2 0 21:56 ?

15

2 0 21:56 ?

16

2 0 21:56 ?

17

2 0 21:56 ?

18

2 0 21:56 ?

19

2 0 21:56 ?

20

2 0 21:56 ?

21

2 0 21:56 ?

22

2 0 21:56 ?

23

2 0 21:56 ?

24

2 0 21:56 ?

25

2 0 21:56 ?

26

2 0 21:56 ?

27

2 0 21:56 ?

28

2 0 21:56 ?

29

2 0 21:56 ?

30

2 0 21:56 ?

31

2 0 21:56 ?

32

2 0 21:56 ?

33

2 0 21:56 ?

34

2 0 21:56 ?

35

2 0 21:56 ?

36

2 0 21:56 ?

37

2 0 21:56 ?

38

2 0 21:56 ?

39

2 0 21:56 ?

40

2 0 21:56 ?

41

2 0 21:56 ?

00:00:02 init [3] 00:00:00 [kthreadd] 00:00:04 [ksoftirqd/0] 00:00:00 [kworker/0:0H] 00:00:00 [posixcputmr/0] 00:00:00 [kclksetdelayd] 00:00:00 [rcub/0] 00:00:04 [rcu_preempt] 00:00:00 [rcu_sched] 00:00:00 [rcu_bh] 00:00:03 [rcuc/0] 00:00:00 [kcmosdelayd] 00:00:00 [migration/0] 00:00:00 [migration/1] 00:00:03 [rcuc/1] 00:00:04 [ksoftirqd/1] 00:00:00 [posixcputmr/1] 00:00:00 [kworker/1:0] 00:00:00 [kworker/1:0H] 00:00:00 [migration/2] 00:00:10 [rcuc/2] 00:00:02 [ksoftirqd/2] 00:00:00 [posixcputmr/2] 00:00:00 [kworker/2:0] 00:00:00 [kworker/2:0H] 00:00:00 [migration/3] 00:00:01 [rcuc/3] 00:00:01 [ksoftirqd/3] 00:00:00 [posixcputmr/3] 00:00:00 [kworker/3:0] 00:00:00 [kworker/3:0H] 00:00:00 [migration/4] 00:00:01 [rcuc/4] 00:00:01 [ksoftirqd/4] 00:00:00 [posixcputmr/4] 00:00:00 [kworker/4:0] 00:00:00 [kworker/4:0H] 00:00:00 [migration/5] 00:00:01 [rcuc/5]

937
Release Information
Command introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION show system processes
show vmhost resource-usage
IN THIS SECTION Syntax | 937 Description | 938 Options | 938 Required Privilege Level | 938 Sample Output | 939 Release Information | 940
Syntax
show vmhost resource-usage <invoke-on> <re0 | re1> <routing engine>

938
Description
Display the current usage of solid-state drive (SSD), RAM, and CPU resources of the host OS.

Options

invoke-on

(Optional) Display information about resources used by the host OS running on a device that has dual Routing Engines. You can use the all-routing-engine option to display information about resources used by the host OS on all the Routing Engines or the otherrouting-engine option to display information about resources used by the host OS on the other Routing Engine. For example, If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display information about resources used by the host OS on the Routing Engine in slot 0 (re0) or on the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine for which the information about resources used by the host OS is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and the backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

Required Privilege Level
view

939

Sample Output
show vmhost resource-usage

user@host> show vmhost resource-usage Compute cluster: rainier-re-cc

Compute node: rainier-re-cn CPU Usage ========= 23:15:09 CPU %usr %nice
%idle 23:15:09 all 0.36 0.00
24.34 23:15:09 0 1.42 0.00
93.81 23:15:09 1 1.43 0.00
94.38 23:15:09 2 0.02 0.00
1.22 23:15:09 3 0.00 0.00
1.21 23:15:09 4 0.00 0.00
1.19 23:15:09 5 0.00 0.00
1.19 23:15:09 6 0.00 0.00
1.19 23:15:09 7 0.00 0.00
1.19

%sys %iowait %irq %soft %steal %guest 1.16 0.07 0.00 0.01 0.00 74.07 4.46 0.28 0.00 0.03 0.00 0.00 3.87 0.30 0.00 0.03 0.00 0.00 0.42 0.00 0.00 0.01 0.00 98.33 0.14 0.00 0.00 0.00 0.00 98.65 0.09 0.00 0.00 0.00 0.00 98.71 0.10 0.00 0.00 0.00 0.00 98.71 0.11 0.00 0.00 0.00 0.00 98.70 0.12 0.00 0.00 0.00 0.00 98.68

Memory Usage

============

total

Mem:

63851

Swap:

0

used 51388
0

free 12462
0

shared 0

buffers 35

cached 123

Disk Usage ========== Filesystem rootfs

Size Used Avail Use% Mounted on 3.3G 127M 3.0G 5% /

940

/dev/sda4 tmpfs none tmpfs tmpfs /dev/mapper/jvg_P-jlvmrootrw unionfs none tmpfs tmpfs /dev/mapper/jvg_P-jlvmjunos /dev/mapper/jvg_P-jlvmvm /dev/mapper/jvg_P-jlvmspare cgroup unionfs tmpfs named tmpfs bind unionfs cache/bind unionfs localtime none random none none

2.0G 32G 32G 32G 32G
3.3G 3.3G
32G 32G 32G 32G 6.1G 287M 32G 3.3G 32G
32G
3.3G
3.3G
32G
32G 32G

1.7G 1.2M 4.0K
0 0 127M 127M 4.0K 180K 8.0K 13G 2.7G 2.1M 0 127M 180K
180K
127M
127M
4.0K
4.0K 4.0K

166M 32G 32G 32G 32G
3.0G 3.0G
32G 32G 32G 18G 3.1G 266M 32G 3.0G 32G
32G
3.0G
3.0G
32G
32G 32G

91% /.old 1% /.old/run 1% /.old/dev 0% /.old/tmp 0% /.old/tdev 5% /.old/tdev/.union/.s 5% / 1% /dev 1% /run 1% /var/volatile
43% /junos 47% /vm
1% /spare 0% /sys/fs/cgroup 5% /run/named-chroot/etc/bind 1% /run/named-chroot/var/run/
1% /run/named-chroot/var/run/
5% /run/named-chroot/var/
5% /run/named-chroot/etc/
1% /run/named-chroot/dev/
1% /run/named-chroot/dev/zero 1% /run/named-chroot/dev/null

It is normal to see 100 percentage or close to 100 percentage of CPU usage in the %guest column in the CPU Usage section.

Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

941
show vmhost snapshot
IN THIS SECTION Syntax | 941 Description | 941 Options | 941 Required Privilege Level | 942 Sample Output | 942 Release Information | 943

Syntax
show vmhost snapshot <invoke-on> <re0 | re1> <routing engine>

Description
Display snapshot details including Linux host kernel version, software version, and other package version details for both the sets of software in the backup disk.

Options

invoke-on

(Optional) Display the host snapshot information of Routing Engines on a device that has dual Routing Engines. You can use the all-routing-engine option to display the host snapshot information of all the Routing Engines or the other-routing-engine option to display the host snapshot information of the other Routing Engine. For example, If you

942

re0 | re1 routingengine

issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.
(Optional) On devices that support dual or redundant Routing Engines, display host snapshot information about the Routing Engine in slot 0 (re0) or the Routing Engine in slot 1 (re1).
(Optional) Specify the Routing Engine for which the host snapshot details is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

Required Privilege Level
view
Sample Output
show vmhost snapshot
user@host> show vmhost snapshot UEFI Version: NGRE_v00.53.00.01 Secondary Disk, Snapshot Time: Tue Dec 8 19:49:09 UTC 2015

943
Version: set p VMHost Version: 2.897 VMHost Root: vmhost-x86_64-15.1I20151203_0011_rbu-builder VMHost Core: vmhost-core-x86_64-15.1I20151203_0011_rbu-builder kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt Junos Disk: junos-install-x86-64-15.1F-20151204.0 Version: set b VMHost Version: 2.897 VMHost Root: vmhost-x86_64-15.1I20151203_0011_rbu-builder VMHost Core: vmhost-core-x86_64-15.1I20151203_0011_rbu-builder kernel: 3.10.79-ovp-rt74-WR6.0.0.20_preempt-rt Junos Disk: junos-install-x86-64-15.1F-20151204.0
Release Information
Command introduced in Junos OS Release 15.1F3.
NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION request vmhost software rollback | 905 request vmhost snapshot | 889
show vmhost status
IN THIS SECTION Syntax | 944 Description | 944

944
Options | 944 Required Privilege Level | 945 Sample Output | 945 Release Information | 946

Syntax
show vmhost status <invoke-on> <re0 | re1> <routing engine>

Description
Display information about the status of communication between the host OS and the guest OS. The following status outputs are displayed: · Online--Communication between the host OS and the guest OS is good. · Offline--Communication with the host is lost. Any state other than Online is considered as Offline.

Options

invoke-on

(Optional) Display the status of communication between the host OS and the guest OS running on a router with dual Routing Engines. You can use the all-routing-engine option to display the status of host-to-guest communication on all the Routing Engines or the otherrouting-engine option to display the status of host-to-guest communication on the other Routing Engine. For example, If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

945

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display the status of communication between the host OS and the guest OS on the Routing Engine in slot 0 (re0) or on the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine for which the status of communication between the host OS and the guest OS is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

Required Privilege Level
view
Sample Output
show vmhost status
user@host> show vmhost status Compute cluster: rainier-re-cc
Compute Node: rainier-re-cn, Online

946
Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
show vmhost uptime
IN THIS SECTION Syntax | 946 Description | 946 Options | 947 Required Privilege Level | 947 Sample Output | 947 Release Information | 948
Syntax
show vmhost uptime <invoke-on> <re0 | re1> <routing engine>
Description
Display the current time and information such as how long the host OS has been running, number of users, average load, and reason for the last reboot that occurred.

947

Options

invoke-on

(Optional) Display the uptime information about the host on a device with dual Routing Engines. You can use the all-routing-engine option to display the uptime information about the host on all the Routing Engines or the other-routing-engine option to display the uptime information about the host on the other Routing Engine. For example, If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display the uptime information about the hoston the Routing Engine in slot 0 (re0) or on the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine for which the uptime information about the host is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and backup Routing Engines. · local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.

Required Privilege Level
view
Sample Output

948 show vmhost uptime
show vmhost uptime
Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.
RELATED DOCUMENTATION show chassis routing-engine
show vmhost version
IN THIS SECTION Syntax | 949 Description | 949 Options | 949 Required Privilege Level | 950 Sample Output | 950 Release Information | 950

949
Syntax
show vmhost version <invoke-on> <re0 | re1> <routing engine>

Description
Display host version information including Linux host kernel version, host software version, and other package version details for both the sets of software in the primary disk.

Options

invoke-on

(Optional) Display the version information of the host running on a device with dual Routing Engines. You can use the all-routing-engine option to display the version information of the host software running on all the Routing Engines or the other-routing-engine option to display the version information of the host software running on other Routing Engine. For example, If you issue the command from the primary Routing Engine, the backup Routing Engine is referred to as the other Routing Engine.

re0 | re1

(Optional) On devices that support dual or redundant Routing Engines, display version information of the host software on the Routing Engine in slot 0 (re0) or on the Routing Engine in slot 1 (re1).

routingengine

(Optional) Specify the Routing Engine for which the version information of the host software is to be displayed. The following options are available:

NOTE: The QFX10002-60C and PTX10002-60C devices do not have primary and backup routing engines.

· backup--Backup Routing Engine. · both--Primary and backup Routing Engines.

950
· local--Routing Engine on the local Virtual Chassis member. · master--Primary Routing Engine. · other--If you issue the command from the primary Routing Engine, the backup Routing
Engine is referred to as the other Routing Engine.
Required Privilege Level
view
Sample Output
show vmhost version
show vmhost version
Release Information
Command introduced in Junos OS Release 15.1F3. NOTE: PTX3000 router supports the Routing and Control Board, RCBPTX.

16 CHAPTER
Configuration Statements from Junos SDK Guide
control-cores | 953 data-cores | 954 data-flow-affinity | 956 destination (Chassis) | 957 extension-provider | 959 forwarding-db-size | 961 hash-key (Chassis) | 963 ip-address-owner | 964 jdaf | 966 object-cache-size | 968 package (Loading on PIC) | 970 policy-db-size | 971 process | 973 process-monitor | 975 resource-cleanup | 977 routing-instances | 978 service-order | 980 syslog (Chassis) | 982

traceoptions (Process Monitor) | 984 traceoptions (Resource Cleanup) | 987 wired-max-processes | 990 wired-process-mem-size | 991

953
control-cores
IN THIS SECTION Syntax | 953 Hierarchy Level | 953 Description | 953 Options | 954 Required Privilege Level | 954 Release Information | 954
Syntax
control-cores control-number;
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]
Description
Configure control cores. Any cores not configured as either control or data cores are treated as user cores. When the number of control cores is changed, the PIC reboots.

954
Options
control-number--Number of control cores. At least one core must be a control core. · Range: 1 through 8
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.0.
RELATED DOCUMENTATION data-cores | 954
data-cores
IN THIS SECTION Syntax | 955 Hierarchy Level | 955 Description | 955 Options | 955 Required Privilege Level | 955 Release Information | 956

955
Syntax
data-cores data-number;
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]
Description
Configure data cores. Any cores not configured as either data or control cores are treated as user cores. When the number of data cores is changed, the PIC reboots.
Options
data-number--Number of data cores. Although it is not mandatory to dedicate any cores as data cores, it is advisable, depending on the nature of the application, to dedicate a minimum of five as data cores to achieve good performance. · Range: 0 through 7
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.

956
Release Information
Statement introduced in Junos OS Release 9.0.
RELATED DOCUMENTATION control-cores | 953
data-flow-affinity
IN THIS SECTION Syntax | 956 Hierarchy Level | 956 Description | 957 Required Privilege Level | 957 Release Information | 957
Syntax
data-flow-affinity { hash-key (layer-3 | layer-4);
}
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]

957
Description
Enable flow affinity distribution for packets over data CPUs on the PIC. Once enabled, the default behavior distributing data packets changes from a round-robin distribution to a flow affinity distribution based on a hash distribution. Adding or deleting this statement causes the PIC to reboot. The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.5.
destination (Chassis)
IN THIS SECTION Syntax | 958 Hierarchy Level | 958 Description | 958 Options | 958 Required Privilege Level | 958 Release Information | 959

958
Syntax
destination destination;
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider syslog facility]
Description
Configure where log messages go. By default, all messages go to the /var/log directory on the Routing Engine. Enhancements to the existing infrastructure make debugging on the Multiservices PIC easier by giving the user the option of redirecting log messages. When the syslog destination statement is configured to redirect the log messages, you can use the set system syslog command, a command available in the native Junos OS CLI, to override the syslog settings made on the Multiservices PIC.
Options
destination--Choose one of the following options: · routing-engine--Forward log messages to the Routing Engine. · pic-console--Forward log messages to the console of the PIC.
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.

959
Release Information
Statement introduced in Junos OS Release 10.1.
RELATED DOCUMENTATION extension-provider | 959
extension-provider
IN THIS SECTION Syntax | 959 Hierarchy Level | 960 Description | 960 Required Privilege Level | 960 Release Information | 961
Syntax
extension-provider { control-cores control-number; data-cores data-number; data-flow-affinity { hash-key (layer-3 | layer-4); } forwarding-db-size size; object-cache-size size; package package-name; policy-db-size size; syslog { facility {

960
severity; destination destination; } } wired-max-processes num-procs; wired-process-mem-size mem-size; }
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package]
Description
Configure an application on a PIC.
CAUTION: Do not configure these settings unless it is specified you should do so. The default settings work under most normal scenarios. Unneeded settings can cause negative effects.
NOTE: The PICs of MS-MPC and MS-MIC support only extension-provider service-package.
When the extension-provider statement is first configured, the PIC reboots. The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.

961
Release Information
Statement introduced in Junos OS Release 9.0.
forwarding-db-size
IN THIS SECTION Syntax | 961 Hierarchy Level | 961 Description | 962 Options | 962 Required Privilege Level | 962 Release Information | 962
Syntax
forwarding-db-size size;
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]

962
Description
Configure the size of the forwarding database (FDB). When this setting is changed, the PIC reboots. NOTE: You need to enable the forwarding-options sampling statement for the FDB to be created.
Options
size--Size of the FDB, in megabytes (MB). The size of the FDB and the size of the policy database together must be smaller than the size of the object cache. · Range: 0 through 12879 MB
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.2.
RELATED DOCUMENTATION policy-db-size | 971 wired-process-mem-size | 991 object-cache-size | 968

963
hash-key (Chassis)
IN THIS SECTION Syntax | 963 Hierarchy Level | 963 Description | 963 Default | 964 Options | 964 Required Privilege Level | 964 Release Information | 964
Syntax
hash-key (layer-3 | layer-4);
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider data-flow-affinity]
Description
Set the hashing distribution of flow affinity. This is an optional setting. Once the data-flow-affinity statement is enabled, you may need to choose the hashing distribution. Modifying this statement causes the PIC to reboot.

964
Default
If you do not configure the hash-key statement, the hashing distribution is 5-tuple hashing, or layer-4.
Options
layer-3--3-tuple hashing (source IP address, destination IP address, and IP protocol). layer-4--5-tuple hashing (3-tuple plus source and destination TCP or UDP ports).
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 10.2.
RELATED DOCUMENTATION extension-provider | 959
ip-address-owner
IN THIS SECTION Syntax | 965 Hierarchy Level | 965

965
Description | 965 Options | 965 Required Privilege Level | 966 Release Information | 966

Syntax
ip-address-owner owner;

Hierarchy Level
[edit interfaces interface-name unit logical-unit-number]

Description
Define the owner for IP addresses hosted on an ms- interface. This statement is used to specify that the steering of control plane packets to the Multiservices PIC be preserved. The provider of your application or its user documentation will tell you when you need to set this configuration.

Options

owner Owner of the IP address for the interface. There are two options: · Values:

routingengine

IP address defined on the interface is hosted by the Routing Engine. This option is not used.

966

serviceplane

IP address defined on the interface is hosted by the service plane. This option is used to preserve the packet steering behavior built into your application. The provider of your application or its user documentation will tell you when you need to set this configuration.

Required Privilege Level
view
Release Information
Statement introduced in Junos OS Release 13.2R1.
jdaf
IN THIS SECTION Syntax | 967 Hierarchy Level | 967 Description | 967 Required Privilege Level | 967 Release Information | 967

967
Syntax
jdaf { routing-instances [ routing-instance-names ];
}
Hierarchy Level
[edit services]
Description
Configure Juniper distributed application framework (JDAF). The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 14.1.

968
object-cache-size
IN THIS SECTION Syntax | 968 Hierarchy Level | 968 Description | 968 Options | 969 Required Privilege Level | 969 Release Information | 969
Syntax
object-cache-size value;
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]
Description
Configure the size of the object cache. When this setting is changed, the PIC reboots.

969
Options
value--Amount of object cache, in MB. Only values in increments of 128 MB are allowed. · Range: For Multiservices 100 PIC, range is 128 MB through 512 MB. If the wired-process-mem-size
statement at the same hierarchy level has a value of 512 MB, the maximum value for this statement is 128 MB. · Range: For Multiservices 400 PIC, range is 128 MB through 1280 MB. If the wired-process-memsize statement at the same hierarchy level has a value of 512 MB, the maximum value for this statement is 512 MB.
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.0.
RELATED DOCUMENTATION forwarding-db-size | 961 policy-db-size | 971 wired-process-mem-size | 991

970
package (Loading on PIC)
IN THIS SECTION Syntax | 970 Hierarchy Level | 970 Description | 970 Options | 971 Required Privilege Level | 971 Release Information | 971
Syntax
package package-name;
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]
Description
Identify a package to be loaded on the PIC. When a package is added or removed, the PIC reboots.

971
Options
package-name--Name of the package to be loaded on the PIC. There can be up to eight packages loaded on a PIC; however, only one data package is allowed per PIC. An error message is displayed if more than eight packages are specified.
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.1.
policy-db-size
IN THIS SECTION Syntax | 972 Hierarchy Level | 972 Description | 972 Options | 972 Required Privilege Level | 972 Release Information | 973

972
Syntax
policy-db-size size;
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]
Description
Configure the size of the policy database. When this setting is changed, the PIC reboots. NOTE: At least one data core must be configured to configure the size of the policy database.
Options
size--Size of the policy database, in megabytes (MB). The size of the forwarding database and the size of the policy database together must be smaller than the size of the object cache. · Range: 0 through 1279 MB
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.

973
Release Information
Statement introduced in Junos OS Release 9.3.
RELATED DOCUMENTATION forwarding-db-size | 961 object-cache-size | 968 wired-process-mem-size | 991
process
IN THIS SECTION Syntax | 973 Description | 974 Options | 974 Required Privilege Level | 974 Release Information | 974
Syntax
process process-ui-name { resources { cpu { priority number; time seconds; } file { core-size bytes; open number;

974
size bytes; } memory {
data-size bytes; locked-in bytes; resident-set-size bytes; socket-buffers bytes; stack-size bytes; } } }
Description
Set resource limits for a process in an application package. Limits defined for individual processes override the limits defined for an entire package.
Options
process-ui-name--Name of the process. The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
admin--To view this statement in the configuration. admin-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.6.

975
RELATED DOCUMENTATION extensions
process-monitor
IN THIS SECTION Syntax | 975 Hierarchy Level | 976 Description | 976 Options | 976 Required Privilege Level | 976 Release Information | 976
Syntax
process-monitor { disable; traceoptions { file filename files number match regex size size (world-readable | no-
world-readable); flag flag; level level; no-remote-trace;
} }

976
Hierarchy Level
[edit system processes]
Description
Configure tracing options for the process health monitor process (pmond). NOTE: Starting with Junos OS Release 15.1R2, the pmond process is enabled by default on the Routing Engines of MX Series routers, even when no service interfaces are configured.
Options
disable--Disable the process health monitor process. The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
admin--To view this statement in the configuration. admin-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.0.
RELATED DOCUMENTATION traceoptions (Process Monitor) | 984

977
resource-cleanup
IN THIS SECTION Syntax | 977 Hierarchy Level | 977 Description | 978 Options | 978 Required Privilege Level | 978 Release Information | 978
Syntax
resource-cleanup { disable; traceoptions { file filename files number match regex size size (world-readable | no-
world-readable); flag flag; level level; no-remote-trace;
} }
Hierarchy Level
[edit system processes]

978
Description
Selectively turn on or off the debugging of trace messages for the resource cleanup process.
Options
disable--Disable the resource cleanup process. The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
trace--To view this statement in the configuration. trace-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.3.
RELATED DOCUMENTATION traceoptions (Resource Cleanup) | 987
routing-instances
IN THIS SECTION Syntax | 979 Hierarchy Level | 979

979
Description | 979 Options | 979 Required Privilege Level | 979 Release Information | 980

Syntax
routing-instances [ routing-instance-names ];

Hierarchy Level
[edit services jdaf]

Description
Configure the routing instances on which Juniper Distributed Application Framework (JDAF) is enabled. If the jdaf statement is not configured, then JDAF is disabled.

Options
routing-instances [ routing-instancenames ]

Name or names of routing instances for JDAF clients. If multiple names are being configured, these can be set as an open set of values.

Required Privilege Level
system--To view this statement in the configuration.

980
system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 14.1.
RELATED DOCUMENTATION jdaf | 966
service-order
IN THIS SECTION Syntax | 980 Hierarchy Level | 981 Description | 981 Options | 981 Required Privilege Level | 981 Release Information | 981
Syntax
service-order { forward-flow [ service-name1 service-name2 ]; reverse-flow [ service-name1 service-name2 ];
}

981
Hierarchy Level
[edit services service-set service-set-name]
Description
Define the order of services in service set to be applied to traffic coming to the PIC. NOTE: If the extension-service statement is specified, the service-order statement is mandatory.
Options
forward-flow--Order of services in service set to be applied in forward flow. reverse-flow--Order of services in service set to be applied in reverse flow. If you want the order to be the reverse of that specified for forward flow, this is optional. However, if, for example, you want the order to be the same regardless of direction of flow, you must include this statement. (The exception to this is for the sampling service set type. If a service set is a sampling service set and the reverse-flow service order is not configured, all sampled traffic is considered to be forward traffic.)
Required Privilege Level
system--To view this statement in the configuration. system-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.3.

982
RELATED DOCUMENTATION extension-service
syslog (Chassis)
IN THIS SECTION Syntax | 982 Hierarchy Level | 982 Description | 983 Options | 983 Required Privilege Level | 983 Release Information | 984
Syntax
syslog { facility { severity; destination destination; }
}
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]

983
Description
Enable PIC system logging to record or view system log messages on a specific PIC. The system log information is passed to the kernel for logging in the /var/log directory.
Options
facility--Group of messages that are either generated by the same software process or concern a similar condition or activity. Possible values include the following: daemon, external, kernel, and pfe. severity--Classification of effect on functioning. Possible values are the following options: · any--Include all severity levels. · none--Disable logging of the associated facility to a destination. · emergency--System panic or other condition that causes the routing platform to stop functioning. · alert--Conditions that require immediate correction, such as a corrupted system database. · critical--Critical conditions, such as hard errors. · error--Error conditions that generally have less serious consequences than errors in the emergency,
alert, and critical levels. · warning--Conditions that warrant monitoring. · notice--Conditions that are not errors but might warrant special handling. · info--Events or nonerror conditions of interest. The remaining statement is explained separately. See CLI Explorer.
Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.

984
Release Information
Statement introduced in Junos OS Release 9.2. Options daemon and kernel (for facility) introduced in Junos OS Release 9.5.
traceoptions (Process Monitor)
IN THIS SECTION Syntax | 984 Hierarchy Level | 985 Description | 985 Options | 985 Required Privilege Level | 986 Release Information | 987
Syntax
traceoptions { file filename files number match regex size size (world-readable | no-world-
readable); flag flag; level level; no-remote-trace;
}

985
Hierarchy Level
[edit system processes process-monitor]
Description
Enable tracing options for the process health monitor process (pmond). NOTE: Starting with Junos OS Release 15.1R2, the pmond process is enabled by default on the Routing Engines of MX Series routers, even when no service interfaces are configured.

Options

file filename Name of the file to receive the output of the tracing operation. Enclose the name within quotation marks. To include the file statement, you must specify a filename.

files number

(Optional) Maximum number of trace files. When a trace file named trace-file reaches its maximum size, it is renamed trace-file.0, then trace-file.1, and so on, until the maximum number of trace files is reached. Then the oldest trace file is overwritten.

If you specify a maximum number of files, you also must specify a maximum file size with the size option.

flag flag

Specify which tracing operation to perform. To specify more than one tracing operation, include multiple flag statements. You can include the following flags:

· all--Enable all trace options flags.

· events--Trace process state change and cleanup events.

· gencfg--Trace GENCFG blobs recorded for cleanup.

· module--Trace module code.

· sysvsem--Trace SYSV semaphores recorded for cleanup.

986

· sysvshm--Trace SYSV shared memory segments recorded for cleanup.

· tracking--Trace tracking code.

· ui--Trace user interface operations.

level level

Specify the level of debugging output: · all--Match all levels.

· error--Match error conditions.

· info--Match informational messages.

· notice--Match conditions that warrant special handling (but are not errors).

· verbose--Match verbose messages.

· warning--Match warning messages.

match regex no-remotetrace size size

(Optional) Refine the output to include lines that contain the regular expression.
Disable remote tracing.
(Optional) Maximum size of each trace file, in kilobytes (KB), megabytes (MB), or gigabytes (GB). If you specify a maximum file size, you also must specify a maximum number of trace files with the files number option.

· Syntax: xk to specify KB, xm to specify MB, or xg to specify GB

· Range: 10 KB through 1 GB

· Default: 128 KB

world-readable | no- (Optional). Grant all users permission to read log files, or restrict the permission

world-readable

only to the root user and users who have the Junos maintenance permission.

Required Privilege Level
trace--To view this statement in the configuration. trace-control--To add this statement to the configuration.

987
Release Information
Statement introduced in Junos OS Release 9.0.
traceoptions (Resource Cleanup)
IN THIS SECTION Syntax | 987 Hierarchy Level | 987 Description | 988 Options | 988 Required Privilege Level | 989 Release Information | 989
Syntax
traceoptions { file filename files number match regex size size (world-readable | no-world-
readable); flag flag; level level; no-remote-trace;
}
Hierarchy Level
[edit system processes resource-cleanup]

988
Description
Enable debugging tracing for resource cleanup process.

Options

file filename Name of the file to receive the output of the tracing operation. Enclose the name within quotation marks. To include the file statement, you must specify a filename.

files number

(Optional) Maximum number of trace files. When a trace file named trace-file reaches its maximum size, it is renamed trace-file.0, then trace-file.1, and so on, until the maximum number of trace files is reached. Then the oldest trace file is overwritten.

If you specify a maximum number of files, you also must specify a maximum file size with the size option.

flag flag

Specify which tracing operation to perform. To specify more than one tracing operation, include multiple flag statements. You can include the following flags:

· all--Enable all trace options flags.

· events--Trace process state change and cleanup events.

· gencfg----Trace GENCFG blobs recorded for cleanup.

· module--Trace module code.

· sysvsem--Trace SYSV semaphores recorded for cleanup.

· sysvshm--Trace SYSV shared memory segments recorded for cleanup.

· tracking--Trace tracking code.

· ui--Trace user interface operations.

level level Specify the level of debugging output:

· all--Match all levels.

· error--Match error conditions.

· info--Match informational messages.

989

· notice--Match conditions that warrant special handling (but are not errors).

· verbose--Match verbose messages.

· warning--Match warning messages.

match regex no-remotetrace size size

(Optional) Refine the output to include lines that contain the regular expression.
Disable remote tracing.
(Optional) Maximum size of each trace file, in kilobytes (KB), megabytes (MB), or gigabytes (GB). If you specify a maximum file size, you also must specify a maximum number of trace files with the files number option.

· Syntax: xk to specify KB, xm to specify MB, or xg to specify GB

· Range: 10 KB through 1 GB

· Default: 128 KB

world-readable | no- (Optional). Grant all users permission to read log files, or restrict the permission

world-readable

only to the root user and users who have the Junos maintenance permission.

Required Privilege Level
trace--To view this statement in the configuration. trace-control--To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.3.

990
wired-max-processes
IN THIS SECTION Syntax | 990 Hierarchy Level | 990 Description | 990 Options | 991 Required Privilege Level | 991 Release Information | 991
Syntax
wired-max-processes num-procs;
Hierarchy Level
[edit chassis fpc slot-number pic slot-number adaptive-services service-package extension-provider]
Description
Configure the number of processes that use wired process memory. Performance can degrade if a process uses memory beyond its Big TLB memory. If this setting is changed, the PIC will reboot.

991

Options

num-procs

Number of processes that use the reserved wired process memory.

· Range: 1 through 8

Required Privilege Level
interface--To view this statement in the configuration. interface-control--To add this statement to the configuration.

Release Information
Statement introduced in Junos OS Release 11.4.

RELATED DOCUMENTATION
wired-process-mem-size | 991 forwarding-db-size | 961 object-cache-size | 968 policy-db-size | 971

wired-process-mem-size

IN THIS SECTION
Syntax | 992 Hierarchy Level | 992 Description | 992

992
Options | 992 Required Privilege Level | 993 Release Information | 993
Syntax
wired-process-mem-size mem-size;
Hierarchy Level
[edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-provider]
Description
Configure the size of the reserved wired process memory. You can also configure object cache. If this setting is changed, the PIC reboots.
Options
megabytes--Size of the reserved wired process memory, in MB. The only size you can set for this statement is 512 MB. · Default: 512 MB · Range: 0 through 512 MB

993
Required Privilege Level