8000/8100 Series Swing Door Operator
Installation Instructions
Open Stop
The unit is provided with an adjustable full open
stop. Rotate the door to the full open position;
mount the Shaft Stop onto the upper output shaft
and against the Fixed Stop. The spline of the output shaft allows indexing in 6° increments.
For finer adjustment, the Fixed Stop is slightly eccentric; loosen and rotate until the desired stop
location is achieved and re-tighten.

Shaft Stop
Fixed Stop

For installations where severe physical abuse may occur (such as extreme wind conditions), it
is suggested a floor mounted stop be installed at full open. Additionally, the operator full open
stop can be set at 100 degrees or more of opening, and program the operator to electronically
stop at the 90 degree full open position. This can be accomplished by manually stopping the
door at 90 degrees during a calibration run, or by reducing the opening angle under the parameter “Drive / Opening angle” (using an FPC902 Hand Terminal or a Display Control Panel).
Power Supply Connection
Connect 115VAC, 60 Hz, 10A, to Power Supply terminal strip
115VAC "Hot" (Line) to "L" terminal;
115VAC "Neutral" to "N" terminal
The second "L" and "N" terminals provide a convenient
junction for dual operator systems.
Proper grounding must be provided for the unit. A grounding
tab and screw are located adjacent to the Power Supply terminal strip.
The power supply cover must be installed after connecting
115VAC primary service.
The multifunction pushbutton can be used for
the following functions:
1 flash of the red LED will actuate a standard
open cycle (if the rocker switch is on).
3 flashes of the red LED will initiate a
calibration run.
4 flashes of the red LED will initiate the parameter adjust mode of a Display Control Panel.
8 flashes of the red LED will reset the unit’s
parameters to factory defaults.
15-17 flashes will cause the unit to reset without
affecting any of the field set parameters.
After completion of the mechanical installation and prior to adjusting the parameters,
always initiate a calibration run by pressing and holding the pushbutton for 3 flashes of
the red LED. This will insure proper door operation by calibrating the unit to the installation conditions.

-USA

6
9/06
Updated

02/07



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:856e36dd-9e52-11e4-0000-25289f94bfef
Producer                        : Bullzip PDF Printer / www.bullzip.com / Freeware Edition
Modify Date                     : 2015:01:14 09:09:58-05:00
Create Date                     : 2015:01:14 09:09:58-05:00
Creator Tool                    : UnknownApplication
Document ID                     : uuid:856e36dd-9e52-11e4-0000-25289f94bfef
Format                          : application/pdf
Title                           : A-S8000InstallationSep11.pdf
Creator                         : 102-STT
Author                          : 102-STT
EXIF Metadata provided by EXIF.tools

Navigation menu