testo Instruments 05601557 Digital manifold User Manual
testo Instruments (Shenzhen) Co., Ltd Digital manifold
user manual
testo 557 · Digital manifold Instruction manual 2 1 Contents Pos : 1 /TD /Übersc hriften/1. Inhalt @ 0\mod_1177587817070_79.doc x @ 1243 @ 1 @ 1 Contents Contents .................................................................................. 3 Safety and the environment ..................................................... 4 2.1. About this document ............................................................ 4 2.2. Ensure safety ......................................................................... 4 2.3. Protecting the environment .................................................. 5 Product description .................................................................. 5 3.1. Use......................................................................................... 5 3.2. Overview ............................................................................... 6 First steps ................................................................................ 8 Using the manifold ................................................................. 10 5.1. Preparing for measurement ................................................ 10 5.1.1. Switching the instrument on...................................................................................... 10 5.1.2. Connecting the temperature sensor .......................................................................... 11 5.1.3. Connecting the vacuum probe ................................................................................... 12 5.1.4. Switching Bluetooth® on and off ............................................................................... 12 5.1.5. Measuring mode........................................................................................................ 12 5.2. Performing the measurement............................................. 13 Technical data ........................................................................ 17 6.1.1. Bluetooth Modul ....................................................................................................... 17 6.1.2. General technical data ............................................................................................... 18 Maintaining the product......................................................... 20 Tips and assistance ................................................................. 22 8.1. Questions and answers ....................................................... 22 8.2. Measurement parameters .................................................. 22 8.3. Error reports........................................................................ 23 8.4. Accessories and spare parts ................................................ 23 Pos : 2 /TD /--- Seitenwechsel --- @ 0\mod_1173774430601_0.doc x @ 283 @ @ 1 2 Safety and the environment Pos : 3 /TD /Übersc hriften/2. Sic herheit und U mwelt @ 0\mod_1173774719351_79.doc x @ 292 @ 1 @ 1 Safety and the environment Pos : 4 /TD /Übersc hriften/2.1 Zu di esem Dokument @ 0\mod_1173775252351_79.doc x @ 346 @ 2 @ 1 2.1. About this document Pos : 5 /TD /Sic herheit und U mwelt/Z u di esem Dokument/Ver wendung/Ver wendung (Standar d) @ 0 \mod_1173775068554_79.doc x @ 337 @ 5 @ 1 Use > Please read this documentation carefully and familiarize yourself with the product before putting it to use. Pay particular attention to the safety instructions and warning advice in order to prevent injuries and damage to the product. Pos : 6 /TD /Sic herheit und U mwelt/Z u di esem Dokument/Symbole und Schr eibkonventi onen/Symbole und Schr eibkonv. [Standar d_groß ] @ 0\mod_1174982140622_79.doc x @ 515 @ 5 @ 1 Symbols and writing standards Representation Explanation Warning advice, risk level according to the signal word: Warning! Serious physical injury may occur. Caution! Slight physical injury or damage to the equipment may occur. > Implement the specified precautionary measures. Menu Elements of the instrument, the instrument display or the program interface. [OK] Control keys of the instrument or buttons of the program interface. Pos : 7 /TD /Übersc hriften/2.2 Sic her hei t gewährl eisten @ 0\mod_1173780783960_79.doc x @ 366 @ 2 @ 1 2.2. Ensure safety Pos : 8 /TD /Sic herheit und U mwelt/Sic her heit gewährl eisten/Gerät bei Bes chädigung en nic ht i n Betrieb nehmen @ 0\mod_1186985945375_79.doc x @ 2252 @ @ 1 > Do not operate the instrument if there are signs of damage at the housing, mains unit or hoses. Pos : 9 /TD /Sic herheit und U mwelt/Sic her heit gewährl eisten/Keine M ess ung an s pannungsführ enden Teil en @ 0\mod_1175692564164_79.doc x @ 592 @ @ 1 Pos : 10 /TD/Sic her heit und U mwelt/Sicherheit g ewährleis ten/Nic ht mi t Lös ungsmittel n l agern @ 0\mod_1175692375179_79.doc x @ 583 @ @ 1 > Do not store the product together with solvents. Do not use any desiccants. Pos : 11 /TD/Sic her heit und U mwelt/Sicherheit g ewährleis ten/N ur besc hriebene Wartungs arbeiten durchführen @ 0\mod_1175692705195_79.doc x @ 601 @ @ 1 > Carry out only the maintenance and repair work on this instrument that is described in the documentation. Pos : 12 /TD/Sic her heit und U mwelt/Sicherheit g ewährleis ten/vor Or t gültige Sic herheits bes ti mmungen beac hten @ 0\mod_1186997107328_79.doc x @ 2298 @ @ 1 > Dangers may also arise from the refrigeration systems being measured or the measuring environment: Note the safety regulations valid in your area when performing the measurements. 3 Product description Pos : 13 /TD/Sic her heit und U mwelt/Sicherheit g ewährleis ten/tes to 550/Mec hanis che Bel astung testo 550 @ 4\mod_1252656121693_79.doc x @ 49837 @ @ 1 > If the manifold falls or another comparable mechanical load occurs, the pipe sections of the refrigerant hoses may break. The valve stem shutoff may also be damaged, whereby further damage to the interior of the manifold may occur that cannot be identified from the outside. The refrigerant hoses must therefore be replaced with new, undamaged refrigerant hoses every time the manifold falls or following any other comparable mechanical load. Send the manifold to Testo Customer Service for a technical check for your own safety. Pos : 14 /TD/Sic her heit und U mwelt/Sicherheit g ewährleis ten/tes to 550/El ektr ostatisc he Aufl adung testo 550 @ 6\mod_1276764428065_79.doc x @ 62673 @ @ 1 > To prevent damage from ESD (electro-static discharge) or transient voltage spikes make sure that your refrigeration system is properly grounded, as otherwise the manifold might get damaged. Pos : 15 /TD/Ü berschriften/2.3 U mwelt s chütz en @ 0 \mod_1173780843645_79.doc x @ 375 @ 2 @ 1 2.3. Protecting the environment Pos : 16.1 /TD/Sicher heit und U mwel t/U mwelt sc hütz en/Akkus /Bat terien ents orgen @ 0\mod_1175693637007_79.doc x @ 619 @ @ 1 > Dispose of spent batteries in accordance with the valid legal specifications. Pos : 16.2 /TD/Sicher heit und U mwel t/U mwelt sc hütz en/Pr odukt entsorgen @ 0\mod_1173780307072_79.doc x @ 357 @ @ 1 > At the end of its useful life, send the product to the separate collection for electric and electronic devices (observe local regulations) or return the product to Testo for disposal. Pos : 17 /TD/Sic her heit und U mwelt/U mwelt sc hütz en/testo 550/Kältemittel können s chaden tes to 550 @ 4\mod_1252656710421_79.doc x @ 49869 @ @ 1 > Refrigerant gases can harm the environment. Please note the applicable environmental regulations. Pos : 18 /TD/Ü berschriften/3. Leistungs beschr eibung @ 0\mod_1173774791554_79.doc x @ 301 @ 1 @ 1 Product description Pos : 19 /TD/Ü berschriften/3.1 Ver wendung @ 0\mod_1176211016437_79.doc x @ 695 @ 2 @ 1 3.1. Use Pos : 20 /TD/Leistungs bes chr eibung/Verwendung/testo 5xxtesto 557 @ 7\mod_1289392871218_79.doc x @ 72935 @ @ 1 Testo 549 and testo 550 are digital manifolds for maintenance and service work on refrigeration systems and heat pumps. They are intended for use by qualified personnel only. The functions of the testo 549 and testo 550 are designed to replace analog manifolds, thermometers and pressure/temperature charts. Pressures and temperatures can be applied, adapted, tested and monitored. Testo 549 and testo 550 are compatible with most non-corrosive refrigerants, water and glycol. Testo 549 and testo 550 are not compatible with refrigerants containing ammonia. The instruments must not be used in explosive environments! 3 Product description Pos : 21 /TD/Ü berschriften/3.2 T ec hnisc he D aten @ 0\mod_1176211088437_79.doc x @ 704 @ 2 @ 1 Pos : 23 /TD/Ü berschriften/4. Produktbeschr eibung @ 0\mod_1173774846679_79.doc x @ 310 @ 1 @ 1 Pos : 24 /TD/Ü berschriften/4.1 Ü bersic ht @ 0\mod_1176379946003_79.doc x @ 733 @ 2 @ 1 3.2. Overview Pos : 25 /TD/Produktbes chr eibung/Ü bersicht/testo 5571 @ 17\mod_1426500685437_79.doc x @ 211786 @ 5 @ 1 Display and control elements 13 10 10 12 11 1 Front connection for external vacuum probe 2 Mini-DIN probe socket for NTC temperature probe, with socket cover 3 Foldable hanging hook (on rear) 3 Product description 4 Display. Instrument status icons: Icon Meaning Battery status Bluetooth® Select measuring mode 5 Battery compartment. The rechargeable batteries cannot be charged inside the instrument! 6 Control keys: Key Function [Set] Set units [R, ►, ■] Select refrigerant / Start-Stop leak test [Mode] Switch between measuring modes [Min/Max/Mean] Display min, max, mean values [▲] Up-key: Scroll through menu. [P=0] Pressure zeroing Esc Switches to the measurement/home view. [▼] Down-key: Scroll through menu. Switching the instrument on/off Switching display ilumination on/off. 7 Sight glass for refrigerant flow. 8 4 x valve stem shutoff 9 4 x hose holders for refrigerant hoses 10 2 x Connection 1/4" SAE, brass. High pressure, for refrigerant hoses with quick release screw fitting, passage for valve actuator lockable. 11 Connection 3/8" SAE, brass, for vacuum pump 12 Connection 1/4" SAE, brass, for e.g. refrigerant cylinders 13 Mini-USB connection for firmware update, inside the battery compartment. 4 First steps : 24 /TD/--- Seitenwec hsel --- @ 0\mod_1173774430601_0.doc @ 281 Pos : 26 /TD/Ü berschriften/5. Erste Sc hritte @ 0\mod_1173774895039_79.doc x @ 319 @ 1 @ 1 First steps Pos : 27 /TD/Erste Schritte/testo 5571 @ 17\mod_1426501068054_79.doc x @ 211821 @ 5555 @ 1 Inserting batteries/rechargeable batteries 1. Fold out the hanging hook and open the battery compartment by squeezing the clip lock. 2. Insert batteries (included in delivery) or rechargeable batteries (4x 1.5 V, type AA/Mignon/LR6) in the battery compartment. Observe the polarity! 3. Close the battery compartment. - After inserting the batteries, the instrument switches on automatically and goes into the settings menu. When not in use for long period: Remove batteries / rechargeable batteries. Units / Parameter selection 1. Press [Set] to confirm or change unit parameter settings 2. Press [▲] or [▼] to change the units / parameters. - The settings will be accepted once the last selection has been made. Key Functions Description [▲] or [▼] Change parameters and select units [Set] Confirm units / parameters Selectable parameters Description °C, °F Temperature unit bar, kPa, MPa, psi Unit for pressure. Pabs, Prel or psig Switch between absolute and relative pressure display micron, inHg, Pa, hPa, mTorr,Torr, inH2O, mbar Unit for vacuum pressure. Select measuring mode: heat pump / cooling / or Auto 0 Selectable parameters Description AUTO OFF Activate or deactivate Automatic power-off. Instrument switches off after 30 minutes if no temperature probe is connected and there is no pressure apart from ambient pressure Tfac Activate or deactivate surface temperature compensation factor, icon is shown on the display if the function is deactivated Settings will be applied following the final selection. Operating the valve stem shutoffs The digital manifold acts like a conventional two-way manifold with regard to the refrigerant path: The passages are opened by opening the valves. The adjacent pressure is measured with valves closed as well as with them open. > Open valve: Turn valve positioner counterclockwise. > Close valve: Turn valve positioner clockwise. WARNING Over tightening the valve stem shutoffs may cause: • Damage to the PTFE seal. • Mechanical deformation of the valve piston leading to the PTFE seal falling out. • Damage to the thread of the threaded spindle and the valve screw. • valve knobs to brake. Lightly tighten the valve knob. Do not use tools to tighten the valve stem shutoffs. Pos : 28 /TD/Ü berschriften/6. Produkt ver wenden @ 0\mod_1173774928554_79.doc x @ 328 @ 1 @ 1 5 Using the manifold Using the manifold Pos : 29 /TD/Produkt ver wenden/testo 557/Ans chli eßen, nullen, ei nstellen @ 7 \mod_1289402475839_79.doc x @ 73068 @ 23553555555 @ 1 5.1. Preparing for measurement 5.1.1. Switching the instrument on > Press [ ]. Zero the pressure sensors before every measurement. ✓ All connections must be at ambient pressure. > Press [P=0] key for 3 seconds to execute zeroing. Connecting the refrigerant hoses Before each measurement check whether the refrigerant hoses are in flawless condition. ✓ Make sure the valve stem shutoffs are closed. 1. Connect the refrigerant hoses to the low-pressure side (blue) and high-pressure side (red). 2. Connect the refrigerant hoses to the AC/R system. WARNING Dropping this instrument or any other comparable mechanical shock can damage the refrigerant pipes and hoses. The valve actuators may also suffer damage, which in turn could result in further damage inside the instrument and may not be detectable from outside. > For your own safety you should return the manifold to the Testo Service Department for technical inspection. > You should therefore always replace the refrigerant hoses with new ones after an accidental drop has occurred or after any visible wear and tear. Choosing the refrigerant 1. Press [R, ►, ■]. - It activates the refrigerant menu and the currently selected refrigerant flashes. 2. Setting the refrigerant: 10 5 Using the manifold Key functions Description [▲] or [▼] Selectng another refrigerant [R, ►, ■] Confirm the selection and exit the refrigerant menu Available refrigerants Representation Description R... Refrigerant number of refrigerant acc. to ISO 817 --- no refrigerant selected. Example: Setting refrigerant R401B 1. Press [R, ►, ■] to activate refrigerant menu. 2. Press [▲] or [▼] several times, until R401B flashes. 3. Press [R, ►, ■] to confirm the setting. Exiting the refrigerant selection > Press [R, ►, ■] or automatically after 30 s, if no other key has been pressed. 5.1.2. Connecting the temperature sensor Surface temperature sensor At least one NTC temperature probe must be connected to measure the pipe temperature, for automatic calculation of superheating and subcooling. Deactivating the surface compensation factor for insertion and air temperature sensor A surface compensation factor has been set in the measuring instrument to improve the measuring accuracy of surface temperature readings. If the manifold is used in combination with insertion or air temperature probe (optional), this factor must be deactivated: 1. Press [Set] repeatedly until Tfac is displayed. 2. Press [▲] or [▼] to set Tfac to Off. 3. Press [Set] to continue through the settings menu until the measurement/home view is displayed. - Tfac is shown on the display if Tfac is disabled. 11 5 Using the manifold Pos : 30 /TD/Produkt ver wenden/testo 557/Vakuumsonde ansc hließ en @ 16\mod_1421057560179_79.doc x @ 206127 @ 3 @ 1 5.1.3. Connecting the vacuum probe > Open the front cover of the connector and connect up the vacuum probe. Pos : 31 /TD/Produkt ver wenden/testo 557/Bluetooth Übersc hrift 557 @ 16 \mod_1421058427681_79.doc x @ 206167 @ 3 @ 1 5.1.4. Switching Bluetooth® on and off Pos : 32 /TD/Produkt ver wenden/testo 557/Bluetooth ei n-aussc halten @ 16\mod_1418732441244_79.doc x @ 205497 @ @ 1 In order to to establish a connection via Bluetooth, on an Android or iOS device, the Testo App Refrigeration must be already installed. You can get the App for iOS instruments in the App Store or for Android instruments in the Play Store. Information about compatibility can be found in the relevant app store. 1. To turn on the Bluetooth press [▲] and [▼] simultaneously and hold down for 3 seconds. - Once the Bluetooth icon is shown on the display, Bluetooth is switched on. Display Description There is no Bluetooth connection, or a potential connection is being searched for. flashes There is a Bluetooth connection. is permanently displayed Bluetooth is disabled. is not displayed 2. To turn off the Bluetooth press [▲] and [▼] simultaneously and hold down for 3 seconds. - Once the Bluetooth icon is no longer shown on the display, Bluetooth is switched off. Pos : 33 /TD/Produkt ver wenden/testo 557/M ess modus tes to 557 @ 7\mod_1289403350250_79.doc x @ 73134 @ 3 @ 1 5.1.5. Measuring mode Display 12 Mode Function Refrigeration system Normal function of the digital manifold Heat pump Normal function of the digital manifold 5 Using the manifold Display Mode Function Automatic mode If the automatic mode is activated, the testo 557 digital manifold automatically changes the display of the high and low pressure. This automatic change occurs when the pressure on the low-pressure side is 1 bar (15 psi) higher than the pressure on the high-pressure side. During the change, Load (2 s) is shown in the display. This mode is especially suited to air conditioning systems which cool and heat (heat pumps). Pos : 34 /TD/Produkt ver wenden/testo 557/M ess ung durc hführen testo 5571 @ 17\mod_1426501166387_79.doc x @ 211856 @ 255555 @ 1 5.2. Performing the measurement WARNING Risk of injury caused by refrigerant that is at high pressure, hot, cold, or poisonous! > Wear safety goggles and protective gloves.. > Before pressurizing the measuring instrument: Always fasten the measuring instrument at the hanging hook in order to prevent it from falling (risk of breakage) > Check if the refrigerant hoses are intact and connected correctly before each measurement. Do not use a tool to connect the hoses. Only tighten the hoses by hand (max. torque 5.0 Nm/3.7 ft*lb). > Do not exceed the permissible measuring range (0 to 870 psi / 0 to 60 bar). Pay particular attention with systems with refrigerant R744, as these are often operated with higher pressures. Measuring 1. Connect and apply pressure to the manifold. 2. See readings. Note: With refrigerants that have a temperature glide, “Zeotropes” the evaporation temperature Ev/to and 13 5 Using the manifold condensation temperature Co/tc are displayed after evaporation and condensation are complete. Zeotropes (refrigerants blends mix together) can separate from each other, unlike azeotropes which mix together to become one. Zeoptropes often blend refrigerants with different boiling points (saturation temps), where one will change from liquid to vapor before the other as they go through the evaporator. The glide is the difference between the lowest boiling point and the highest boiling point. If they are 3 degrees apart, for example, the blend has a 3 degree glide.. The display illumination will flash if: • The critical pressure of the refrigerant is within 15 psi (1 bar) of the highest pressure (and temperature) where the refrigerant can still condense. • The maximum. permissible pressure of 870 psi (60 bar) is exceeded. Key functions > Press [▲] or [▼] to change the reading in the display. Possible display combinations: Refrigerant evaporation Refrigerant condensation temperature Ev/to (°F/°C) temperature Co/tc (°F/°C) Evaporation pressure Condensation pressure (psi/bar) (psi/bar) 14 Measured temperature T1/toh (°F/°C) Evaporation pressure (psi/bar) Measured temperature T2/tcu (°F/°C) Condensation pressure (psi/bar) Superheating SH/Δtoh (°F/°C) Evaporation pressure (psi/bar) Subcooling SC/Δtcu (°F/°C) Condensation pressure (psi/bar) 5 Using the manifold Changeable - Evaporation Temperature (Ev) - Measured Temperature (T1) - Superheating (SH) Evaporation pressure Changeable - Condensation Temperature (Co) - Measured Temperature (T2) - Subcooling (SC) Condensation pressure With both NTC temperature probes connected, Δt is also shown. > Press [Mean/Min/Max]: to display min. / max. readings and mean values. Leak test / pressure drop test Systems can be tested for tightness with the temperaturecompensated leak test. The system pressure and the ambient temperature are measured over a defined period of time, typically with an inert gas such as Nitrogen. A temperature probe can be connected that measures the ambient temperature. : Optional air temperature probe, part. no. 0613 1712) is recommended. Measurement data of the temperature-compensated differential pressure and temperature, from start to the end of the test, is displayed. It is possible to perform a leak test without connecting a temperature probe. 1. Press [Mode] ΔP is displayed. 2. Start the leak test: Press [R, ►, ■]. ΔP is now flashing and hh:mm timer is on. 3. End the leak test: Press [R, ►, ■]. ΔP stops flashing and hh:mm timer stops. - Result is displayed. Note: Leak test time duration and ΔP value 4. Confirm the message: Press [Mode] to exit leak mode. 15 5 Using the manifold Duration of test Measured pressure beginning of test Differential pressure start compared to actual Actual measured pressure Vacuum measurement ✓ The vacuum probe is plugged into the front connection of the manifold and connected to the system. 1. Press [Mode] the vacuum mode is displayed. If ambient pressure is applied to the vacuum probe, then oooo is shown on the display. 2. Start the vacuum pump. - Once the measuring range 0 to 20,000 microns is reached, the current vacuum value is shown on the instrument display. The instrument also displays the current ambient temperature, the water evaporation temperature, which corresponds to the vacuum reading, and the delta between these two temperatures. 3. To leave vacuum mode, remove the vacuum probe from the testo 557 or switch to the standard measurement view using the [Mode] button. 16 6 Technical data Technical data Pos : 22 /TD/Leistungs bes chr eibung/T ec hnische D aten/testo 5571 @ 17\mod_1426500292878_79.doc x @ 211611 @ 33 @ 1 6.1.1. Bluetooth Modul The Bluetooth® option may only be operated in countries in which it is type approved. Feature Values Bluetooth Range >20 m (free field) Bluetooth type LSD Science & Technology Co., Ltd L Series BLE Module (08 Mai 2013) based on TI CC254X chip Qualified Design ID B016552 Bluetooth radio class Class 3 Bluetooth company 10274 European Union Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, United Kingdom. EFTA countries Island, Suisse, Norway, Lichtenstein. Other countries USA, Canada, Turkey, Hong Kong, Australia, New Zealand. Information from the FCC (Federal Communications Commission) This device complies with part 15 of the FCC Rules. Its commissioning is subject to the two following conditions: (1) This instrument must not cause any harmful interference and (2) this instrument must be able to cope with interference, even if this has undesirable effects on operation. Changes The FCC demands that the user be informed that any changes or modifications to the instrument that are not explicitly approved by Testo AG may void the user's right to use this instrument. 17 6 Technical data 6.1.2. General technical data Feature Values Parameters Pressure: psi / kPa / MPa / bar Temperature: °F / °C / K Vacuum: micron / inHg / inH2O / hPa / mbar / mTorr /Torr / Pa Sensors 2 Pressure: sensors, 2 Temperature (NTC Thermistors) Measuring cycle 0.5 s Interfaces Pressure connections: 3 x 1/4" SAE, 1x 3/8" SAE NTC measurement External vacuum probe Measuring ranges Pressure measurement range HP/LP: -14.7…870 psi / -100…6000 kPa / -0.1…6 MPa / -1…60 bar (rel) Temperature measurement range: -58…302 °F / -50…+150 °C Measurement range vacuum (abs): 0 … 20.000 micron Overload 940 psi, 65 bar, 6500 kPa, 6.5 MPa Resolution Resolution pressure: 0.1 psi / 0.01 bar / 1 kPa / 0.001 MPa Resolution temperature: 0.1 °F / 0.1 °C / 0.1 K Vacuum resolution: 1 micron (from 0 to 1000 micron) 10 micron (from 1000 to 2000 micron) 100 micron (from 2000 to 5000 micron) 500 micron (from 5000 to 10000 micron) 5000 micron (from 10000 to 20.000 micron) Pressure: ±0.5% FS (±1 digit) Accuracy (nominal Temperature: -58 to 302°F (0.9°F ± 1 digit) / temperature 71.6 °F 50 to 150°C (±0.5 °C ±1 digit) / 22 °C) Vacuum: ±10% +10 micron No. of refrigerants 18 60 6 Technical data Feature Selectable refrigerants Measurable media Values No refrigerant, R11, R12, R22, R123, R1234ze, R125, R13B1, R134a, R14, R142B, R152a, R161, R23, R227, R290, R32, R401A, R401B, R401C, R402A, R402B, R404A, R406A, R407A, R407B, R407C, R407D, R407F, R408A, R409A, R410A, R411A, R412A, R413A, R414B, R416A, R417A, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R424A, R426A, R427A, R434A, R437A, R438A, R502, R503, R507, R508A, R508B, R600, R600a, R718 (H2O), R744 (CO2) (only in permissible measurement range up to 60 bar), R1234yf All refrigerants that are stored in the testo 557 Ammonia (R717) and other refrigerants which contain ammonia will damage the manifold Ambient conditions Operating temperature: -4…122°F / -20…50°C Storage temperature: -4…140°F / -20…60°C Humidity in area of use: 10… 90%rF Bluetooth Range >20 m / 65 ft (unobstructed field) Housing Material: ABS / PA / TPE Dimensions approx. 280 x 135 x 75 mm Weight: approx. 1200 g (without batteries) IP-class 42 Power supply 4 x 1.5 V, type AA/mignon/LR6 rechargeable or standard batteries Battery life: approx. 250h (display light off, Bluetooth off, vacuum probe not connected) Display Type: Illuminated LCD Response time: 0.5 s Directives, EC Directive: 2014/30/EC standards and tests 19 7 Maintaining the product Feature Values Warranty Duration: 2 years Terms of warranty: see website www.testo.com/warranty Pos : 35 /TD/Ü berschriften/7. Produkt i nstand halten @ 0\mod_1173789831362_79.doc x @ 397 @ 1 @ 1 Maintaining the product Pos : 36 /TD/Produkt i nstand halten/Gerät rei nigen 5571 @ 17\mod_1426501226500_79.doc x @ 211891 @ 2 @ 1 Cleaning the instrument Do not use harsh cleaning agents or solvents! Mild soap and water may be used. > Clean instrument using a damp cloth. Pos : 37 /TD/Produkt i nstand halten/testo 550/Ins tandhalten testo 550 @ 4\mod_1253262226679_79.doc x @ 50494 @ 55555 @ 1 Keeping connections clean > Keep screw connections clean and free of grease and other deposits, clean with a moist cloth as required. Removing oil residues > Carefully blow out oil residues in valve block using compressed air. To ensure measuring accuracy > Check instrument regularly for leaks (recommended: annually). Keep to the permissible pressure range! > Calibrate instrument regularly (recommended: annually). Changing batteries/rechargeable batteries ✓ Instrument is switched off. 1. Fold out the hook, loosen the clip and remove the cover of the battery compartment. 20 7 Maintaining the product 2. Remove discharged batteries/rechargeable batteries and insert new batteries/rechargeable batteries (4x 1.5 V, type AA, Mignon, LR6) in the battery compartment. Observe the polarity! 3. Set on and close cover of the battery compartment (clip must engage). 4. Switch the instrument on. Changing the valve or valve stem shutoff DO NOT ATTEMPT to change the valve stems. Changing the valve stem shutoff or valves themselves will void the warranty. Send the measuring instrument to Testo Customer Service. Cleaning the vacuum probe Contaminants such as oil may impair the accuracy of the vacuum sensor. CAUTION Carrying out cleaning with the probe connected may result in damage to the probe! > Remove the vacuum probe from the testo 557! CAUTION Damage to the sensor due to sharp objects! > Do not insert any sharp objects into the probe! 1. Remove the vacuum probe from the testo 557. 2. Put a few drops of rubbing alcohol into the sensor opening. 3. Seal the opening by placing your finger on it and shake the vacuum probe briefly. 4. Remove all the alcohol from the probe. 5. Repeat this process at least twice. 6. Leave the probe to dry for at least 1 hour. To dry the sensor faster, you can connect the probe directly to a vacuum pump and draw vacuum. 21 8 Tips and assistance Pos : 38 /TD/Ü berschriften/8. Tipps und Hilfe @ 0\mod_1173789887985_79.doc x @ 406 @ 1 @ 1 Tips and assistance Pos : 39 /TD/Ü berschriften/8.1 Fr agen und Antworten @ 0\mod_1177402017078_79.doc x @ 1093 @ 2 @ 1 8.1. Questions and answers Pos : 40 /TD/Ti pps und Hilfe/Fr agen und Antworten/testo 550/FAQ testo 550 @ 5\mod_1265185945986_79.doc x @ 56964 @ @ 1 Question Possible causes/solution flashes Batteries are almost empty. > Change batteries. The instrument switches off automatically. Residual capacity of the batteries is too low. > Change batteries. uuuu lights up instead of the parameter display The permissible measuring range has been undershot. > Keep to the permitted measuring range. oooo lights up instead of the parameter display The permissible measuring range has been exceeded. > Keep to the permitted measuring range. Pos : 41 /TD/Ti pps und Hilfe/Fr agen und Antworten/testo 550/Mes sgrößen tes to 550 @ 5\mod_1265186104485_79.doc x @ 56996 @ 2 @ 1 8.2. Measurement parameters Name Description bar, °C psi, °F Δtoh SH Superheating, evaporation pressure Δtcu SC Subcooling, condensation pressure to Ev Refrigerant evaporation temperature tc Co Refrigerant condensation temperature toh T1 Measured temperature, evaporation tcu T2 Measured temperature, condensation Pos : 42 /TD/Ti pps und Hilfe/F ehler mel dungen/F ehler meldung en testo 550 @ 5\mod_1264166753739_79.doc x @ 56778 @ 2 @ 1 22 8 Tips and assistance 8.3. Error reports Question Possible causes/solution ---- is lit up instead of measurement parameter display Sensor or cable defective > Please contact your dealer or Testo Customer Service Display EEP FAIL Eeprom defective > Please contact your dealer or Testo Customer Service Display BT ERR No BT module connected or BT module defective. > Please contact your dealer or Testo Customer Service Display ERR 1-5 Vac-Probe defect > Please contact your dealer or Testo Customer Service Pos : 43 /TD/Ti pps und Hilfe/Ser vic e-Informati onen (für PoD)/Kontaktdaten allgemein @ 3\mod_1222264220446_79.doc x @ 23423 @ @ 1 Pos : 44 /TD/Ü berschriften/8.3 Z ubehör und Ers atz teil e @ 0 \mod_1177402058734_79.doc x @ 1102 @ 2 @ 1 8.4. Accessories and spare parts Pos : 45 /TD/Ti pps und Hilfe/Z ubehör und Ers atz teil e/Z ubehör tes to 5571 @ 17\mod_1426501312455_79.doc x @ 211926 @ @ 1 Description Article no. Clamp probe for temperature measurement at pipes (1,5m) 0613 5505 Clamp probe for temperature measurement at pipes (5m) 0613 5506 Pipe wrap probe with Velcro tape for pipe diameters of up to max. 75 mm, Tmax. +75 °C, NTC 0613 4611 Watertight NTC surface probe 0613 1912 Precise, robust NTC air probe 0613 1712 External vacuum probe Please contact Testo Service. For a complete list of all accessories and spare parts, please refer to the product catalogues and brochures or look up our website at: www.testo.com If you have any questions, please contact your dealer or Testo Customer Service. The contact details can be found on the back of this document or on the Internet at www.testo.com/servicecontact. Click onto your country’s flag for local support. 23 8 Tips and assistance === Ende der Liste für T extmar ke Inhalt === 24 Testo Inc. 40 White Lake Road Sparta, N. J. 07871 Phone: +1 862 354 5001 Fax: +1 862 354 5020 Email: info@testo.com www.testo.com Headquarter testo AG Testo-Straße 1 79853 Lenzkirch Germany Tel.: +49 7653 681-0 Fax: +49 7653 681-7699 Email: info@testo.de Internet: www.testo.de 0970 5571 en-US 01 V01.11 FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐ Reorient or relocate the receiving antenna. ‐ Increase the separation between the equipment and receiver. ‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐Consult the dealer or an experienced radio/TV technician for help. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada RSS exemptes de licence standard(s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne peut pas provoquer d'interférences, et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. RF exposure information: The Maximum Permissible Exposure (MPE) level has been calculated based on a distance of d=5mm between the device and the human body. To maintain compliance with RF exposure requirement, use product that maintain a 5mm distance between the device and human body.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Becker, Katharina (TNE, ZE) Create Date : 2015:05:29 15:02:02+08:00 Modify Date : 2015:05:29 15:02:02+08:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2015:05:29 15:02:02+08:00 Creator Tool : Adobe Acrobat Pro 9.3.2 Format : application/pdf Creator : Becker, Katharina (TNE, ZE) Document ID : uuid:a9ae7204-b6da-486e-bf48-954e80987258 Instance ID : uuid:06bec434-73e3-4241-bc7d-9ccec7148abc Producer : Adobe Acrobat Pro 9.3.2 Page Count : 27EXIF Metadata provided by EXIF.tools