u blox 2AGQN4NNN Cellular Module User Manual SARA R4 series System Integration Manual
u-blox AG Cellular Module SARA R4 series System Integration Manual
u blox >
Contents
User Manual
SARA-R4 series Size-optimized LTE Cat M1 modules System Integration Manual Abstract This document describes the features and the system integration of SARA-R4 series cellular modules. These modules are a complete, cost efficient and performance optimized LTE Cat M1 solution in the compact SARA form factor. www.u-blox.com UBX-16029218 - R03 SARA-R4 series - System Integration Manual Document Information Title SARA-R4 series Subtitle Size-optimized LTE Cat M1 modules Document type System Integration Manual Document number UBX-16029218 Revision and date R03 24-May-2017 Disclosure restriction Product Status Corresponding content status Functional Sample Draft For functional testing. Revised and supplementary data will be published later. In Development / Prototype Objective Specification Target values. Revised and supplementary data will be published later. Engineering Sample Advance Information Data based on early testing. Revised and supplementary data will be published later. Initial Production Early Prod. Information Data from product verification. Revised and supplementary data may be published later. Mass Production / End of Life Production Information Final product specification. This document applies to the following products: Name Type number Firmware version PCN reference Product Status SARA-R404M SARA-R404M-00B-00 K0.0.00.00.07.03 UBX-17016454 Engineering Sample SARA-R410M SARA-R410M-01B-00 L0.0.00.00.01 UBX-17013995 Prototype u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of u-blox is strictly prohibited. The information contained herein is provided “as is” and u-blox assumes no liability for the use of the information. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time. For most recent documents, please visit www.u-blox.com. Copyright © 2017, u-blox AG u-blox® is a registered trademark of u-blox Holding AG in the EU and other countries. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. UBX-16029218 - R03 Page 2 of 94 SARA-R4 series - System Integration Manual Preface u-blox Technical Documentation As part of our commitment to customer support, u-blox maintains an extensive volume of technical documentation for our products. In addition to our product-specific technical data sheets, the following manuals are available to assist u-blox customers in product design and development. AT Commands Manual: This document provides the description of the AT commands supported by the u-blox cellular modules. System Integration Manual: This document provides the description of u-blox cellular modules’ system from the hardware and the software point of view, it provides hardware design guidelines for the optimal integration of the cellular modules in the application device and it provides information on how to set up production and final product tests on application devices integrating the cellular modules. Application Note: These documents provide guidelines and information on specific hardware and/or software topics on u-blox cellular modules. See Related documents for a list of Application Notes related to your Cellular Module. How to use this Manual The SARA-R4 series System Integration Manual provides the necessary information to successfully design and configure the u-blox cellular modules. This manual has a modular structure. It is not necessary to read it from the beginning to the end. The following symbols are used to highlight important information within the manual: An index finger points out key information pertaining to module integration and performance. A warning symbol indicates actions that could negatively impact or damage the module. Questions If you have any questions about u-blox Cellular Integration: Read this manual carefully. Contact our information service on the homepage http://www.u-blox.com/ Technical Support Worldwide Web Our website (http://www.u-blox.com/) is a rich pool of information. Product information, technical documents can be accessed 24h a day. By E-mail Contact the closest Technical Support office by email. Use our service pool email addresses rather than any personal email address of our staff. This makes sure that your request is processed as soon as possible. You will find the contact details at the end of the document. Helpful Information when Contacting Technical Support When contacting Technical Support, have the following information ready: Module type (SARA-R404M) and firmware version Module configuration Clear description of your question or the problem A short description of the application Your complete contact details UBX-16029218 - R03 Preface Page 3 of 94 SARA-R4 series - System Integration Manual Contents Preface ................................................................................................................................ 3 Contents.............................................................................................................................. 4 System description ....................................................................................................... 7 1.1 1.2 Overview .............................................................................................................................................. 7 Architecture .......................................................................................................................................... 8 1.3 Pin-out ................................................................................................................................................. 9 1.4 1.5 Operating modes ................................................................................................................................ 12 Supply interfaces ................................................................................................................................ 14 1.5.1 Module supply input (VCC) ......................................................................................................... 14 1.5.2 Generic digital interfaces supply output (V_INT) ........................................................................... 16 1.6 System function interfaces .................................................................................................................. 17 1.6.1 Module power-on ....................................................................................................................... 17 1.6.2 1.6.3 Module power-off ....................................................................................................................... 18 Module reset ............................................................................................................................... 20 1.7 Antenna interface ............................................................................................................................... 21 1.7.1 1.7.2 1.8 SIM interface ...................................................................................................................................... 22 1.8.1 1.8.2 1.9 Antenna RF interface (ANT) ......................................................................................................... 21 Antenna detection interface (ANT_DET) ...................................................................................... 22 SIM interface ............................................................................................................................... 22 SIM detection interface ............................................................................................................... 22 Data communication interfaces .......................................................................................................... 23 1.9.1 1.9.2 UART interface ............................................................................................................................ 23 USB interface............................................................................................................................... 25 1.9.3 DDC (I C) interface ...................................................................................................................... 26 1.10 1.11 General Purpose Input/Output ........................................................................................................ 26 Reserved pins (RSVD) ...................................................................................................................... 26 1.12 System features............................................................................................................................... 27 1.12.1 1.12.2 Network indication ...................................................................................................................... 27 Antenna supervisor ..................................................................................................................... 27 1.12.3 Dual stack IPv4/IPv6 ..................................................................................................................... 27 1.12.4 1.12.5 TCP/IP and UDP/IP ....................................................................................................................... 27 FTP .............................................................................................................................................. 27 1.12.6 HTTP ........................................................................................................................................... 28 1.12.7 1.12.8 Firmware update Over AT (FOAT) ................................................................................................ 28 Firmware update Over The Air (FOTA) ......................................................................................... 28 1.12.9 Power saving ............................................................................................................................... 28 Design-in ..................................................................................................................... 30 2.1 Overview ............................................................................................................................................ 30 2.2 Supply interfaces ................................................................................................................................ 31 UBX-16029218 - R03 Contents Page 4 of 94 SARA-R4 series - System Integration Manual 2.2.1 2.2.2 2.3 System functions interfaces ................................................................................................................ 42 2.3.1 2.3.2 2.4 Antenna RF interface (ANT) ......................................................................................................... 44 Antenna detection interface (ANT_DET) ...................................................................................... 51 SIM interface ...................................................................................................................................... 53 2.5.1 2.5.2 2.6 Module power-on (PWR_ON) ...................................................................................................... 42 Module reset (RESET_N) .............................................................................................................. 43 Antenna interface ............................................................................................................................... 44 2.4.1 2.4.2 2.5 Module supply (VCC) .................................................................................................................. 31 Generic digital interfaces supply output (V_INT) ........................................................................... 41 Guidelines for SIM circuit design.................................................................................................. 53 Guidelines for SIM layout design ................................................................................................. 57 Data communication interfaces .......................................................................................................... 58 2.6.1 2.6.2 UART interface ............................................................................................................................ 58 USB interface............................................................................................................................... 63 2.6.3 DDC (I C) interface ...................................................................................................................... 65 2.7 2.8 General Purpose Input/Output ............................................................................................................ 65 Reserved pins (RSVD) .......................................................................................................................... 66 2.9 Module placement.............................................................................................................................. 66 2.10 2.11 Module footprint and paste mask ................................................................................................... 67 Thermal guidelines .......................................................................................................................... 68 2.12 Schematic for SARA-R4 series module integration ........................................................................... 69 2.12.1 Schematic for SARA-R4 series modules ........................................................................................ 69 2.13 Design-in checklist .......................................................................................................................... 70 2.13.1 Schematic checklist ..................................................................................................................... 70 2.13.2 2.13.3 Layout checklist ........................................................................................................................... 71 Antenna checklist ........................................................................................................................ 71 Handling and soldering ............................................................................................. 72 3.1 3.2 Packaging, shipping, storage and moisture preconditioning ............................................................... 72 Handling ............................................................................................................................................. 72 3.3 Soldering ............................................................................................................................................ 73 3.3.1 3.3.2 Soldering paste............................................................................................................................ 73 Reflow soldering ......................................................................................................................... 73 3.3.3 Optical inspection ........................................................................................................................ 74 3.3.4 3.3.5 Cleaning...................................................................................................................................... 74 Repeated reflow soldering ........................................................................................................... 75 3.3.6 Wave soldering............................................................................................................................ 75 3.3.7 3.3.8 Hand soldering ............................................................................................................................ 75 Rework........................................................................................................................................ 75 3.3.9 Conformal coating ...................................................................................................................... 75 3.3.10 3.3.11 Casting........................................................................................................................................ 75 Grounding metal covers .............................................................................................................. 75 3.3.12 Use of ultrasonic processes .......................................................................................................... 75 Approvals.................................................................................................................... 76 UBX-16029218 - R03 Contents Page 5 of 94 SARA-R4 series - System Integration Manual 4.1 4.2 Product certification approval overview ............................................................................................... 76 US Federal Communications Commission notice ................................................................................. 77 4.2.1 Safety warnings review the structure ........................................................................................... 77 4.2.2 4.2.3 Declaration of Conformity ........................................................................................................... 77 Modifications .............................................................................................................................. 78 Product testing ........................................................................................................... 82 5.1 5.2 u-blox in-series production test ........................................................................................................... 82 Test parameters for OEM manufacturer .............................................................................................. 83 5.2.1 “Go/No go” tests for integrated devices ...................................................................................... 83 5.2.2 RF functional tests ....................................................................................................................... 83 Appendix .......................................................................................................................... 85 A Migration between SARA-R4 and SARA-G3 ............................................................. 85 A.1 Overview ............................................................................................................................................ 85 A.2 Pin-out comparison between SARA-R4 and SARA-G3 ......................................................................... 87 A.3 Schematic for SARA-R4 and SARA-G3 integration .............................................................................. 89 Glossary ...................................................................................................................... 90 Related documents........................................................................................................... 92 Revision history ................................................................................................................ 93 Contact .............................................................................................................................. 94 UBX-16029218 - R03 Contents Page 6 of 94 SARA-R4 series - System Integration Manual 1 System description 1.1 Overview The SARA-R4 series comprises LTE Cat M1 modules supporting data transmission in the miniature SARA LGA form-factor (26.0 x 16.0 mm, 96-pin), that allows an easy integration in compact designs and a seamless drop-in migration from u-blox cellular module families. SARA-R4 series modules are form-factor compatible with u-blox LISA, LARA and TOBY cellular module families and are pin-to-pin compatible with u-blox SARA-N, SARA-G and SARA-U cellular module families. This facilitates migration from the u-blox NB-IoT, GSM/GPRS, CDMA, UMTS/HSPA and other LTE modules, maximizes customers investments, simplifies logistics, and enables very short time-to-market. The modules are ideal for LPWA applications with low to medium data throughput rates, as well as devices that require long battery lifetimes, such as connected health, smart metering, smart cities and wearables. SARA-R4 series includes the following modules: SARA-R404M single-band modules designed primarily to operate in North America on Verizon network SARA-R410M-01B quad-band modules designed primarily to operate in North America on AT&T network LTE Cat M1 supports vehicular handover capability and delivers the technology necessary to enable the use of the modules in applications such as vehicle, asset and people tracking where mobility is a pre-requisite. Other applications where the module is well suited include and are not limited to: smart home, security systems, industrial monitoring and control. SARA-R4 series modules support data communication with a throughput of 375 kb/s. Table 1 summarizes the main features and interfaces of SARA-R4 series modules. eDRX Antenna supervisor Jamming detection Embedded TCP/UDP stack Embedded HTTP, FTP Dual stack IPv4/IPv6 FW update over the air (FOTA) ● ○ ○ ● ○ ● ○ ● ○ ● ● ● ● 2,4 5,12 ● ● ○ ○ ● ○ ● ○ ● ○ ● ● ● ● SARA-R410M-01B N. America 13 M1 ● = supported by all product versions Automotive Power Saving Mode ● Professional Digital audio 13 Standard GPIOs 13 M1 Analog audio DDC (I2C) Grade SDIO Features USB 2.0 Audio UART USA Interfaces LTE FDD Bands SARA-R404M Bands 3GPP LTE category Region 3GPP Release Baseline Module ○ = supported by future product versions Table 1: SARA-R4 series main features summary UBX-16029218 - R03 System description Page 7 of 94 SARA-R4 series - System Integration Manual Table 2 reports a summary of cellular radio access technologies characteristics and features of the modules. Item SARA-R4 Series Protocol stack release 3GPP Release 13 Frequency Division Duplex (FDD) Half-Duplex Operating band SARA-R404M modules: Band 13 (750 MHz) SARA-R410M-01B modules: Band 12 (700 MHz) Band 5 (850 MHz) Band 4 (1700 MHz) Band 2 (1900 MHz) Power class Power Class 3 (23 dBm) Data rate LTE category M1, up to 375 kb/s DL/UL Table 2: SARA-R4 series characteristics summary 1.2 Architecture Figure 1 summarizes the internal architecture of SARA-R4 series modules. PA Filter ANT SIM Switch RF transceiver SIM card detection UART USB Cellular BaseBand Processor Memory 19.2 MHz VCC (Supply) V_INT (I/O) Reset DDC (I2C) GPIO Power Management Antenna detection Power-On Figure 1: SARA-R4 series modules simplified block diagram UBX-16029218 - R03 System description Page 8 of 94 SARA-R4 series - System Integration Manual 1.3 Pin-out Table 3 lists the pin-out of the SARA-R4 series modules, with pins grouped by function. Function Pin Name Pin No I/O Description Remarks Power VCC 51, 52, 53 Module supply input VCC supply circuit affects the RF performance and compliance of the device integrating the module with applicable required certification schemes. See section 1.5.1 for functional description / requirements. See section 2.2.1 for external circuit design-in. GND 1, 3, 5, 14, N/A 20-22, 30, 32, 43, 50, 54, 55, 57-61, 63-96 Ground GND pins are internally connected each other. External ground connection affects the RF and thermal performance of the device. See section 1.5.1 for functional description. See section 2.2.1 for external circuit design-in. V_INT Generic digital interfaces supply output V_INT = 1.8 V (typical) generated by internal regulator when the module is switched on, outside the low power PSM deep sleep mode. Test-Point for diagnostic access is recommended. See section 1.5.2 for functional description. See section 2.2.2 for external circuit design-in. PWR_ON 15 Power-on input Internal 200 k pull-up resistor. See section 1.6.1 for functional description. See section 2.3.1 for external circuit design-in. RESET_N 18 External reset input Internal pull-up resistor to V_INT. Test-Point for diagnostic access is recommended. See section 1.6.3 for functional description. See section 2.3.2 for external circuit design-in. ANT 56 I/O Primary antenna Main Tx / Rx antenna interface. 50 nominal characteristic impedance. Antenna circuit affects the RF performance and application device compliance with required certification schemes. See section 1.7 for functional description / requirements. See section 2.4 for external circuit design-in. ANT_DET 62 Antenna detection ADC for antenna presence detection function See section 1.7.2 for functional description. See section 2.4.2 for external circuit design-in. VSIM 41 SIM supply output VSIM = 1.8 V / 3 V output as per the connected SIM type. See section 1.8 for functional description. See section 2.5 for external circuit design-in. SIM_IO 39 I/O SIM data Data input/output for 1.8 V / 3 V SIM Internal 4.7 k pull-up to VSIM. See section 1.8 for functional description. See section 2.5 for external circuit design-in. SIM_CLK 38 SIM clock 3.25 MHz clock output for 1.8 V / 3 V SIM See section 1.8 for functional description. See section 2.5 for external circuit design-in. SIM_RST 40 SIM reset Reset output for 1.8 V / 3 V SIM See section 1.8 for functional description. See section 2.5 for external circuit design-in. System Antenna SIM UBX-16029218 - R03 System description Page 9 of 94 SARA-R4 series - System Integration Manual Function Pin Name Pin No I/O Description Remarks UART RXD 13 UART data output 1.8 V output, Circuit 104 (RXD) in ITU-T V.24, for AT commands, data communication, FOAT. See section 1.9.1 for functional description. See section 2.6.1 for external circuit design-in. TXD 12 UART data input 1.8 V input, Circuit 103 (TXD) in ITU-T V.24, for AT commands, data communication, FOAT. Internal active pull-up to V_INT. See section 1.9.1 for functional description. See section 2.6.1 for external circuit design-in. CTS 11 UART clear to send output 1.8 V output, Circuit 106 (CTS) in ITU-T V.24. See section 1.9.1 for functional description. See section 2.6.1 for external circuit design-in. RTS 10 UART ready to send input 1.8 V input, Circuit 105 (RTS) in ITU-T V.24. Internal active pull-up to V_INT. See section 1.9.1 for functional description. See section 2.6.1 for external circuit design-in. DSR UART data set ready output 1.8 V, Circuit 107 in ITU-T V.24. See section 1.9.1 for functional description. See section 2.6.1 for external circuit design-in. RI UART ring indicator output 1.8 V, Circuit 125 in ITU-T V.24. See section 1.9.1 for functional description. See section 2.6.1 for external circuit design-in. DTR UART data terminal ready input 1.8 V, Circuit 108/2 in ITU-T V.24. Internal active pull-up to V_INT. See section 1.9.1 for functional description. See section 2.6.1 for external circuit design-in. DCD UART data carrier detect output 1.8 V, Circuit 109 in ITU-T V.24. See section 1.9.1 for functional description. See section 2.6.1 for external circuit design-in. VUSB_DET 17 USB detect input VBUS (5 V typical) USB supply generated by the host must be connected to this input pin to enable the USB interface. Test-Point for diagnostic / FW update access is recommended See section 1.9.2 for functional description. See section 2.6.2 for external circuit design-in. USB_D- 28 I/O USB Data Line D- USB interface for AT commands, data communication, FOAT, FW update by u-blox dedicated tool and diagnostic. 90 nominal differential impedance (Z0) 30 nominal common mode impedance (ZCM) Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 specifications [4] are part of the USB pin driver and need not be provided externally. Test-Point for diagnostic / FW update access is recommended. See section 1.9.2 for functional description. See section 2.6.2 for external circuit design-in. USB_D+ 29 I/O USB Data Line D+ USB interface for AT commands, data communication, FOAT, FW update by u-blox dedicated tool and diagnostic. 90 nominal differential impedance (Z0) 30 nominal common mode impedance (ZCM) Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 specifications [4] are part of the USB pin driver and need not be provided externally. Test-Point for diagnostic / FW update access is recommended. See section 1.9.2 for functional description. See section 2.6.2 for external circuit design-in. USB UBX-16029218 - R03 System description Page 10 of 94 SARA-R4 series - System Integration Manual Function DDC GPIO Reserved Pin Name Pin No I/O Description Remarks SCL 27 I C bus clock line 1.8 V open drain, for communication with I2C-slave devices. Internal pull-up to V_INT: external pull-up is not required. See section 1.9.3 for functional description. See section 2.6.3 for external circuit design-in. SDA 26 I/O I2C bus data line 1.8 V open drain, for communication with I2C-slave devices. Internal pull-up to V_INT: external pull-up is not required. See section 1.9.3 for functional description. See section 2.6.3 for external circuit design-in. GPIO1 16 I/O GPIO 1.8 V GPIO with alternatively configurable functions. See section 1.10 for functional description. See section 2.7 for external circuit design-in. GPIO2 23 I/O GPIO 1.8 V GPIO with alternatively configurable functions. See section 1.10 for functional description. See section 2.7 for external circuit design-in. GPIO3 24 I/O GPIO 1.8 V GPIO with alternatively configurable functions. See section 1.10 for functional description. See section 2.7 for external circuit design-in. GPIO4 25 I/O GPIO 1.8 V GPIO with alternatively configurable functions. See section 1.10 for functional description. See section 2.7 for external circuit design-in. GPIO5 42 I/O GPIO 1.8 V GPIO with alternatively configurable functions. See section 1.10 for functional description. See section 2.7 for external circuit design-in. GPIO6 19 I/O GPIO 1.8 V GPIO with alternatively configurable functions. See section 1.10 for functional description. See section 2.7 for external circuit design-in. RSVD 33 N/A Reserved pin This pin can be connected to GND. See sections 1.11 and 2.8 RSVD 2, 31, 34-37, 44-49 N/A Reserved pin Leave unconnected. See sections 1.11 and 2.8 Table 3: SARA-R4 series module pin definition, grouped by function UBX-16029218 - R03 System description Page 11 of 94 SARA-R4 series - System Integration Manual 1.4 Operating modes SARA-R4 series modules have several operating modes. The operating modes are defined in Table 4 and described in detail in Table 5, providing general guidelines for operation. General Status Operating Mode Definition Power-down Not-Powered Mode Power-Off Mode VCC supply not present or below operating range: module is switched off. VCC supply within operating range and module is switched off. Normal Operation Deep-Sleep Mode Active Mode RTC runs with 32 kHz reference internally generated. Module processor core runs with 19.2 MHz reference generated by the internal oscillator Connected Mode RF Tx/Rx data connection enabled and processor core runs with 19.2 MHz reference. Table 4: SARA-R4 series modules operating modes definition Mode Description Transition between operating modes Not-Powered Module is switched off. Application interfaces are not accessible. Power-Off Module is switched off: normal shutdown by an appropriate power-off event (see 1.6.2). Application interfaces are not accessible. When VCC supply is removed, the modules enter not-powered mode. When in not-powered mode, the module can enter power-off mode applying VCC supply (see 1.6.1). The modules enter power-off mode from active mode when the host processor implements a proper switch-off procedure, by sending the AT+CPWROFF command or by using the PWR_ON pin (see 1.6.2). When in power-off mode, the modules can be switched on by the host processor using the PWR_ON input pin (see 1.6.1). When in power-off mode, the modules enter not-powered mode by removing VCC supply. Deep-Sleep Only the internal 32 kHz reference is active. The RF section and the application interfaces are temporarily disabled and switched off: the module is temporarily not ready to communicate with an external device by means of the application interfaces as configured to reduce the current consumption. The module enters the low power deep sleep mode (entering the Power Saving Mode defined in 3GPP Rel.13) whenever possible, if power saving configuration is enabled by AT+CPSMS command (see SARA-R4 series AT Commands Manual [2]), reducing current consumption (see 1.12.9). Power saving configuration is not enabled by default; it can be enabled by AT+CPSMS (see the SARA-R4 series AT Commands Manual [2]). The modules automatically switch from the active mode to low power deep sleep mode whenever possible, upon expiration of “Active Timer”, entering in the Power Saving Mode defined in 3GPP Rel.13, if power saving configuration is enabled (see 1.12.9 and the SARA-R4 series AT Commands Manual [2], AT+CPSMS command). When in low power deep sleep mode, the module switches on to the active mode upon expiration of “Periodic Update Timer” according to the Power Saving Mode defined in 3GPP Rel.13 (see 1.12.9 and the SARA-R4 series AT Commands Manual [2], AT+CPSMS command), or it can be switched on to the active mode by the host processor using the PWR_ON input pin (see section 1.6.1). Active Module is switched on with application interfaces enabled or not suspended: the module is ready to communicate with an external device by means of the application interfaces unless power saving configuration is enabled by AT+CPSMS (see SARA-R4 series AT Commands Manual [2]). The modules enter active mode from power-off mode when the host processor implements a proper switch-on procedure by using the PWR_ON pin (see 1.6.1). The modules enter active mode from low power deep sleep mode upon expiration of “Periodic Update Timer” (see 1.12.9), or when the host processor implements a proper switch-on procedure by using the PWR_ON pin (see 1.6.1). The modules enter power-off mode from active mode when the host processor implements a proper switch-off procedure (see 1.6.2). The modules automatically switch from active to low power deep sleep mode whenever possible, if power saving is enabled (see 1.12.9). The module switches from active to connected-mode when a RF Tx/Rx data connection is initiated or when RF Tx/Rx activity is required due to a connection previously initiated. The module switches from connected to active mode when a RF Tx/Rx data connection is terminated or suspended. UBX-16029218 - R03 System description Page 12 of 94 SARA-R4 series - System Integration Manual Mode Description Transition between operating modes Connected RF Tx/Rx data connection is in progress. The module is prepared to accept data signals from an external device. When a data connection is initiated, the module enters connected mode from active mode. Connected-mode is suspended if Tx/Rx data is not in progress. In such cases the module automatically switches from connected to active mode and then, if power saving configuration is enabled by the AT+CPSMS command, the module automatically switches to low power deep sleep mode whenever possible. Vice-versa, the module wakes up from low power deep sleep mode to active mode and then connected mode if RF Tx/Rx activity is necessary. When a data connection is terminated, the module returns to the active-mode. Table 5: SARA-R4 series modules operating modes description Figure 2 describes the transition between the different operating modes. Not powered Apply VCC Remove VCC Power off Switch ON: • PWR_ON Switch OFF: • AT+CPWROFF • PWR_ON Incoming/outgoing data or other dedicated device network communication Connected If power saving is enabled, and Active Timer is expired Active No RF Tx/Rx in progress, Communication dropped Deep Sleep • Upon expiration of the Periodic Update Timer • Using PWR_ON pin Figure 2: SARA-R4 series modules operating modes transitions UBX-16029218 - R03 System description Page 13 of 94 SARA-R4 series - System Integration Manual 1.5 Supply interfaces 1.5.1 Module supply input (VCC) The modules must be supplied via the three VCC pins that represent the module power supply input. During operation, the current drawn by the SARA-R4 series modules through the VCC pins can vary by several orders of magnitude, depending on the operating mode and state (as described in sections 1.5.1.2, 1.5.1.3 and 1.5.1.4). It is important that the supply source is able to support the average current consumption occurring during a LTE transmission at maximum RF power level. 1.5.1.1 VCC supply requirements Table 6 summarizes the requirements for the VCC modules supply. See section 2.2.1 for suggestions to properly design a VCC supply circuit compliant with the requirements listed in Table 6. The supply circuit affects the RF compliance of the device integrating SARA-R4 series modules with applicable required certification schemes as well as antenna circuit design. Compliance is guaranteed if the requirements summarized in the Table 6 are fulfilled. Item Requirement Remark VCC nominal voltage Within VCC normal operating range: 3.20 V min. / 4.20 V max RF performance is guaranteed when VCC voltage is inside the normal operating range limits. RF performance may be affected when VCC voltage is outside the normal operating range limits, though the module is still fully functional until the VCC voltage is inside the extended operating range limits. VCC voltage during normal operation Within VCC extended operating range: 3.00 V min. / 4.30 V max VCC voltage must be above the extended operating range minimum limit to switch-on the module. The module may switch-off when the VCC voltage drops below the extended operating range minimum limit. Operation above VCC extended operating range is not recommended and may affect device reliability. VCC average current Support with adequate margin the highest averaged VCC current consumption value in connected-mode conditions specified in SARA-R4 Data Sheet [1] The maximum average current consumption can be greater than the specified value according to the actual antenna mismatching, temperature and supply voltage. Section 1.5.1.2 describes current consumption profiles in connected-mode. VCC peak current Support with adequate margin the highest peak VCC current consumption value in Tx connected-mode conditions specified in SARA-R4 Data Sheet [1] The maximum peak Tx current consumption can be greater than the specified value according to the actual antenna mismatching, temperature and supply voltage. Section 1.5.1.2 describes current consumption profiles in connected-mode. VCC voltage ripple during LTE Tx Noise in the supply pins has to be minimized High supply voltage ripple values during RF transmissions in connected-mode directly affect the RF compliance with the applicable certification schemes. Table 6: Summary of VCC modules supply requirements UBX-16029218 - R03 System description Page 14 of 94 SARA-R4 series - System Integration Manual 1.5.1.2 VCC current consumption in connected-mode During an LTE Category M1 connection, the SARA-R4 series modules transmit and receive in half duplex mode. The current consumption depends on output RF power, which is always regulated by the network (the current base station) sending power control commands to the module. These power control commands are logically divided into a slot of 0.5 ms (time length of one Resource Block), thus the rate of power change can reach a maximum rate of 2 kHz. Figure 3 shows an example of SARA-R4 modules’ current consumption profile versus time in connected-mode: transmission is enabled for one sub-frame (1 ms) according to LTE Category M1 half duplex connected-mode. Detailed current consumption values can be found in SARA-R4 series Data Sheet [1]. Current [mA] 500 400 300 Current consumption value depends on TX power and actual antenna load 200 100 1 Slot 1 Resource Block (0.5 ms) 1 LTE Radio Frame (10 ms) Time [ms] Figure 3: VCC current consumption profile versus time during LTE Cat M1 half duplex connection 1.5.1.3 VCC current consumption in low power deep sleep mode (power saving enabled) The power saving configuration is by default disabled, but it can be enabled using the AT+CPSMS command (see SARA-R4 series AT Commands Manual [2] and section 1.12.9). When power saving is enabled, the module automatically enters the PSM low power deep sleep mode whenever possible, reducing current consumption down to a steady value in the µA range: only the RTC runs with internal 32 kHz reference clock frequency. Detailed current consumption values can be found in SARA-R4 series Data Sheet [1]. UBX-16029218 - R03 System description Page 15 of 94 SARA-R4 series - System Integration Manual 1.5.1.4 VCC current consumption in active mode (power saving disabled) The active mode is the state where the module is switched on and ready to communicate with an external device by means of the application interfaces (as the USB or the UART serial interface). The module processor core is active, and the 19.2 MHz reference clock frequency is used. If power saving configuration is disabled, as it is by default (see SARA-R4 series AT Commands Manual [2], +CPSMS AT command for details), the module does not automatically enter the PSM low power deep sleep mode whenever possible: the module remains in active mode. Otherwise, if the power saving configuration is enabled, the module enters PSM low power deep sleep mode whenever possible (see section 1.12.9). Figure 4 illustrates a typical example of the module current consumption profile when the module is in active mode. In such case, the module is registered with the network and, while active-mode is maintained, the receiver is periodically activated to monitor the paging channel for paging block reception. Detailed current consumption values can be found in SARA-R4 series Data Sheet [1]. Current [mA] 100 Time [s] Current [mA] Paging period 100 RX Enabled Time [ms] ACTIVE MODE Figure 4: VCC current consumption profile with power saving disabled and module registered with the network: active-mode is always held and the receiver is periodically activated to monitor the paging channel for paging block reception 1.5.2 Generic digital interfaces supply output (V_INT) The V_INT output pin of the SARA-R4 series modules is generated by the module internal power management circuitry when the module is switched on and it is not in the low power deep sleep mode. The typical operating voltage is 1.8 V, whereas the current capability is specified in the SARA-R4 series Data Sheet [1]. The V_INT voltage domain can be used in place of an external discrete regulator as a reference voltage rail for external components. UBX-16029218 - R03 System description Page 16 of 94 SARA-R4 series - System Integration Manual 1.6 System function interfaces 1.6.1 Module power-on When the SARA-R4 series modules are in the not-powered mode (i.e. the VCC module supply is not applied), they can be switched on as follows: Rising edge on the VCC input pins to a valid voltage level, and then a low logic level has to be held at the PWR_ON input pin for a valid time. When the SARA-R4 series modules are in the power-off mode (i.e. switched off) or in the PSM low power mode, with a valid VCC supply applied, they can be switched on as follows: Low pulse on the PWR_ON pin for a valid time period The PWR_ON input pin is equipped with an internal active pull-up resistor. Detailed electrical characteristics with voltages and timings are described in SARA-R4 series Data Sheet [1]. Figure 5 shows the module switch-on sequence from the not-powered mode, describing the following phases: The external power supply is applied to the VCC module pins The PWR_ON pin is held low for a valid time All the generic digital pins of the module are tri-stated until the switch-on of their supply source (V_INT). The internal reset signal is held low: the baseband core and all the digital pins are held in the reset state. When the internal reset signal is released, any digital pin is set in a proper sequence from the reset state to the default operational configured state. The duration of this pins’ configuration phase differs within generic digital interfaces and the USB interface due to host / device enumeration timings (see section 1.9.2). The module is fully ready to operate after all interfaces are configured. Start-up event Start of interface configuration Module interfaces are configured VCC PWR_ON RESET_N V_INT Internal Reset System State BB Pads State OFF Tristate / Floating ON Internal Reset Internal Reset → Operational Operational Figure 5: SARA-R4 series switch-on sequence description The Internal Reset signal is not available on a module pin, but the host application can monitor the V_INT pin to sense the start of the SARA-R4 series module switch-on sequence. Before the switch-on of the generic digital interface supply source (V_INT) of the module, no voltage driven by an external application should be applied to any generic digital interface of the module. Before the SARA-R4 series module is fully ready to operate, the host application processor should not send any AT command over the AT communication interfaces (USB, UART) of the module. UBX-16029218 - R03 System description Page 17 of 94 SARA-R4 series - System Integration Manual 1.6.2 Module power-off SARA-R4 series can be properly switched off by: AT+CPWROFF command (see SARA-R4 series AT Commands Manual [2]). The current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed. Low pulse on the PWR_ON pin for a valid time period (see SARA-R4 series Data Sheet [1]). An abrupt under-voltage shutdown occurs on SARA-R4 series modules when the VCC module supply is removed. If this occurs, it is not possible to perform the storing of the current parameter settings in the module’s non-volatile memory or to perform the proper network detach. It is highly recommended to avoid an abrupt removal of the VCC supply during SARA-R4 series modules normal operations. An abrupt hardware shutdown occurs on SARA-R4 series modules when a low level is applied on RESET_N pin. In this case, the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach is not performed. It is highly recommended to avoid an abrupt hardware shutdown of the module by forcing a low level on the RESET_N input pin during module normal operation: the RESET_N line should be set low only if reset or shutdown via AT commands fails or if the module does not reply to a specific AT command after a time period longer than the one defined in the SARA-R4 series AT Commands Manual [2]. Figure 6 describes the SARA-R4 series modules switch-off sequence started by means of the AT+CPWROFF command, allowing storage of current parameter settings in the module’s non-volatile memory and a proper network detach, with the following phases: When the +CPWROFF AT command is sent, the module starts the switch-off routine. The module replies OK on the AT interface: the switch-off routine is in progress. At the end of the switch-off routine, all the digital pins are tri-stated and all the internal voltage regulators are turned off, including the generic digital interfaces supply (V_INT). Then, the module remains in switch-off mode as long as a switch on event does not occur (e.g. applying a proper low level to PWR_ON), and enters not-powered mode if the supply is removed from the VCC pins. AT+CPWROFF sent to the module OK replied by the module VCC can be removed VCC PWR_ON RESET_N V_INT Internal Reset ON System State BB Pads State Operational Operational → Tristate OFF Tristate / Floating Figure 6: SARA-R4 series switch-off sequence by means of AT+CPWROFF command The Internal Reset signal is not available on a module pin, but the application can monitor the V_INT pin to sense the end of the switch-off sequence. The duration of each phase in the SARA-R4 series modules’ switch-off routines can largely vary depending on the application / network settings and the concurrent module activities. UBX-16029218 - R03 System description Page 18 of 94 SARA-R4 series - System Integration Manual Figure 7 describes the SARA-R4 series modules switch-off sequence started by means of the PWR_ON input pin, allowing storage of current parameter settings in the module’s non-volatile memory and a proper network detach, with the following phases: A low pulse with appropriate time duration (see SARA-R4 series Data Sheet [1]) is applied at the PWR_ON input pin. At the end of the switch-off routine, all the digital pins are tri-stated and all the internal voltage regulators are turned off, including the generic digital interfaces supply (V_INT). Then, the module remains in power-off mode as long as a switch on event does not occur (e.g. applying a proper low level to the PWR_ON input ), and enters not-powered mode if the supply is removed from the VCC pins. The module starts the switch-off routine VCC can be removed VCC PWR_ON RESET_N V_INT Internal Reset ON System State BB Pads State Operational 0s OFF Operational -> Tristate ~2.5 s Tristate / Floating ~5 s Figure 7: SARA-R4 series switch-off sequence by means of PWR_ON pin The Internal Reset signal is not available on a module pin, but the application can monitor the V_INT pin to sense the end of the switch-off sequence. The duration of each phase in the SARA-R4 series modules’ switch-off routines can largely vary depending on the application / network settings and the concurrent module activities. UBX-16029218 - R03 System description Page 19 of 94 SARA-R4 series - System Integration Manual 1.6.3 Module reset SARA-R4 series modules can be properly reset (rebooted) by: AT+CFUN command (see SARA-R4 series AT Commands Manual [2]). In the case listed above an “internal” or “software” reset of the module is executed: the current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed. An abrupt hardware shutdown occurs on SARA-R4 series modules when a low level is applied on RESET_N input pin for a valid time period. In this case, the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach is not performed. Then, the module remains in power-off mode as long as a switch on event does not occur applying a proper low level to the PWR_ON input. It is highly recommended to avoid an abrupt hardware shutdown of the module by forcing a low level on the RESET_N input during modules normal operation: the RESET_N line should be set low only if reset or shutdown via AT commands fails or if the module does not provide a reply to a specific AT command after a time period longer than the one defined in the SARA-R4 series AT Commands Manual [2]. The RESET_N input pin is equipped with an internal pull-up to the V_INT supply. Detailed electrical characteristics with voltages and timings are described in SARA-R4 series Data Sheet [1]. UBX-16029218 - R03 System description Page 20 of 94 SARA-R4 series - System Integration Manual 1.7 Antenna interface 1.7.1 Antenna RF interface (ANT) SARA-R4 series modules provide an RF interface for connecting the external antenna. The ANT pin represents the primary RF input/output for transmission and reception of LTE RF signals. The ANT pin has a nominal characteristic impedance of 50 and must be connected to the primary Tx / Rx antenna through a 50 transmission line to allow proper RF transmission and reception. 1.7.1.1 Antenna RF interfaces requirements Table 7 summarizes the requirements for the antenna RF interface. See section 2.4.1 for suggestions to properly design antennas circuits compliant with these requirements. The antenna circuits affect the RF compliance of the device integrating SARA-R4 series modules with applicable required certification schemes (for more details see section 4). Compliance is guaranteed if the antenna RF interface requirements summarized in Table 7 are fulfilled. Item Requirements Remarks Impedance 50 nominal characteristic impedance Frequency Range See the SARA-R4 series Data Sheet [1] Return Loss S11 < -10 dB (VSWR < 2:1) recommended S11 < -6 dB (VSWR < 3:1) acceptable Efficiency > -1.5 dB ( > 70% ) recommended > -3.0 dB ( > 50% ) acceptable Maximum Gain According to radiation exposure limits Input Power > 24 dBm ( > 0.25 W ) The impedance of the antenna RF connection must match the 50 impedance of the ANT port. The required frequency range of the antenna connected to ANT port depends on the operating bands of the used cellular module and the used mobile network. The Return loss or the S11, as the VSWR, refers to the amount of reflected power, measuring how well the antenna RF connection matches the 50 characteristic impedance of the ANT port. The impedance of the antenna termination must match as much as possible the 50 nominal impedance of the ANT port over the operating frequency range, reducing as much as possible the amount of reflected power. The radiation efficiency is the ratio of the radiated power to the power delivered to antenna input: the efficiency is a measure of how well an antenna receives or transmits. The radiation efficiency of the antenna connected to the ANT port needs to be enough high over the operating frequency range to comply with the Over-The-Air (OTA) radiated performance requirements, as Total Radiated Power (TRP) and the Total Isotropic Sensitivity (TIS), specified by applicable related certification schemes. The power gain of an antenna is the radiation efficiency multiplied by the directivity: the gain describes how much power is transmitted in the direction of peak radiation to that of an isotropic source. The maximum gain of the antenna connected to ANT port must not exceed the herein stated value to comply with regulatory agencies radiation exposure limits. For additional info see sections 4.2.2. The antenna connected to the ANT port must support with adequate margin the maximum power transmitted by the modules. Table 7: Summary of Tx/Rx antenna RF interface requirements UBX-16029218 - R03 System description Page 21 of 94 SARA-R4 series - System Integration Manual 1.7.2 Antenna detection interface (ANT_DET) The antenna detection is based on ADC measurement. The ANT_DET pin is an Analog to Digital Converter (ADC) provided to sense the antenna presence. The antenna detection function provided by ANT_DET pin is an optional feature that can be implemented if the application requires it. The antenna detection is forced by the +UANTR AT command. See the SARA-R4 series AT Commands Manual [2] for more details on this feature. The ANT_DET pin generates a DC current (for detailed characteristics see the SARA-R4 series Data Sheet [1]) and measures the resulting DC voltage, thus determining the resistance from the antenna connector provided on the application board to GND. So, the requirements to achieve antenna detection functionality are the following: an RF antenna assembly with a built-in resistor (diagnostic circuit) must be used an antenna detection circuit must be implemented on the application board See section 2.4.2 for antenna detection circuit on application board and diagnostic circuit on antenna assembly design-in guidelines. 1.8 SIM interface 1.8.1 SIM interface SARA-R4 series modules provide high-speed SIM/ME interface including automatic detection and configuration of the voltage required by the connected SIM card or chip. Both 1.8 V and 3 V SIM types are supported. Activation and deactivation with automatic voltage switch from 1.8 V to 3 V are implemented, according to ISO-IEC 7816-3 specifications. The VSIM supply output provides internal short circuit protection to limit start-up current and protect the SIM to short circuits. The SIM driver supports the PPS (Protocol and Parameter Selection) procedure for baud-rate selection, according to the values determined by the SIM card or chip. 1.8.2 SIM detection interface The GPIO5 pin is configured as an external interrupt to detect the SIM card mechanical / physical presence. The pin is configured as input with an internal active pull-down enabled, and it can sense SIM card presence only if properly connected to the mechanical switch of a SIM card holder as described in section 2.5: Low logic level at GPIO5 input pin is recognized as SIM card not present High logic level at GPIO5 input pin is recognized as SIM card present For more details see SARA-R4 series AT Commands Manual [2], +UGPIOC, +CIND and +CMER AT commands. UBX-16029218 - R03 System description Page 22 of 94 SARA-R4 series - System Integration Manual 1.9 Data communication interfaces SARA-R4 series modules provide the following serial communication interface: UART interface: Universal Asynchronous Receiver/Transmitter serial interface available for the communication with a host application processor (AT commands, data communication, FW update by means of FOAT). See section 1.9.1. USB interface: Universal Serial Bus 2.0 compliant interface available for the communication with a host application processor (AT commands, data communication, FW update by means of the FOAT feature), for FW update by means of the u-blox dedicated tool and for diagnostic. See section 1.9.2. DDC interface: I C bus compatible interface available for the communication with u-blox GNSS positioning chips or modules and with external I C devices. See section 1.9.3. 1.9.1 UART interface 1.9.1.1 UART features The UART interface is a 9-wire 1.8 V unbalanced asynchronous serial interface available on all the SARA-R4 series modules, supporting: AT command mode Data mode and Online command mode Multiplexer protocol functionality FW upgrades by means of the FOAT feature (see 1.12.7) The UART is available only if the USB is not enabled as AT command / data communication interface: UART and USB cannot be concurrently used for this purpose. UART interface provides RS-232 functionality conforming to the ITU-T V.24 Recommendation [5], with CMOS compatible signal levels: 0 V for low data bit or ON state, and 1.8 V for high data bit or OFF state (for detailed electrical characteristics see SARA-R4 series Data Sheet [1]), providing: data lines (RXD as output, TXD as input), hardware flow control lines (CTS as output, RTS as input), modem status and control lines (DTR as input, DSR as output, DCD as output, RI as output). SARA-R4 series modules are designed to operate as cellular modems, i.e. as the data circuit-terminating equipment (DCE) according to the ITU-T V.24 Recommendation [5]. A host application processor connected to the module through the UART interface represents the data terminal equipment (DTE). UART signal names of the cellular modules conform to the ITU-T V.24 Recommendation [5]: e.g. TXD line represents data transmitted by the DTE (host processor output) and received by the DCE (module input). SARA-R4 series modules’ UART interface is by default configured in AT command mode: the module waits for AT command instructions and interprets all the characters received as commands to execute. All the functionalities supported by SARA-R4 series modules can be in general set and configured by AT commands: AT commands according to 3GPP TS 27.007 [6], 3GPP TS 27.005 [7], 3GPP TS 27.010 [8] u-blox AT commands (for the complete list and syntax see the SARA-R4 series AT Commands Manual [2]) For the definition of the interface data mode, command mode and online command mode see SARA-R4 series AT Commands Manual [1] UBX-16029218 - R03 System description Page 23 of 94 SARA-R4 series - System Integration Manual Flow control handshakes are supported by the UART interface and can be set by appropriate AT commands (see SARA-R4 series AT Commands Manual [2], &K, \Q AT commands): hardware flow control (over the RTS / CTS lines), software flow control (XON/XOFF), or none flow control. Hardware flow control is enabled by default. The default baud rate is 115200 b/s, while the default frame format is 8N1 (8 data bits, No parity, 1 stop bit: see Figure 8). Baud rates can be configured by AT command (see SARA-R4 series AT Commands Manual [2]). The automatic baud rate detection and the automatic frame format recognition are not supported. Normal Transfer, 8N1 Start of 1-Byte transfer D0 D1 Possible Start of next transfer D2 D3 D4 D5 D6 Start Bit (Always 0) D7 Stop Bit (Always 1) tbit = 1/(Baudrate) Figure 8: Description of UART 8N1 frame format (8 data bits, no parity, 1 stop bit) 1.9.1.2 UART signals behavior At the module switch-on, before the UART interface initialization (as described in the power-on sequence reported in Figure 5), each pin is first tri-stated and then is set to its relative internal reset state. At the end of the boot sequence, the UART interface is initialized, the module is by default in active-mode, and the UART interface is enabled as AT commands interface. The configuration and the behavior of the UART signals after the boot sequence are described below. See section 1.4 for definition and description of module operating modes referred to in this section. RXD signal behavior The module data output line (RXD) is set by default to the OFF state (high level) at UART initialization. The module holds RXD in the OFF state until the module transmits some data. TXD signal behavior The module data input line (TXD) is set by default to the OFF state (high level) at UART initialization. The TXD line is then held by the module in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the TXD input. CTS signal behavior The module hardware flow control output (CTS line) is set to the ON state (low level) at UART initialization. If the hardware flow control is enabled, as it is by default, the CTS line indicates when the UART interface is enabled (data can be received): the module drives the CTS line to the ON state or to the OFF state when it is either able or not able to accept data from the DTE over the UART. The CTS hardware flow control setting can be changed by AT commands (for more details, see SARA-R4 series AT Commands Manual [2], AT&K, AT\Q AT commands). UBX-16029218 - R03 System description Page 24 of 94 SARA-R4 series - System Integration Manual RTS signal behavior The hardware flow control input (RTS line) is set by default to the OFF state (high level) at UART initialization. The module then holds the RTS line in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the RTS input. If the HW flow control is enabled, as it is by default, the module monitors the RTS line to detect permission from the DTE to send data to the DTE itself. If the RTS line is set to the OFF state, any on-going data transmission from the module is interrupted until the RTS line changes to the ON state. The module behavior according to the RTS hardware flow control status can be configured by AT commands (for more details, see the SARA-R4 series AT Commands Manual [2], AT&K, AT\Q, AT+IFC AT commands). 1.9.1.3 UART multiplexer protocol SARA-R4 series modules include multiplexer functionality as per 3GPP TS 27.010 [8], on the UART physical link. This is a data link protocol which uses HDLC-like framing and operates between the module (DCE) and the application processor (DTE) and allows a number of simultaneous sessions over the used physical link (UART): the user can concurrently use AT interface on one MUX channel and data communication on another MUX channel. The following virtual channels are defined: Channel 0: Multiplexer control Channel 1 – 5: AT commands / data connection 1.9.2 USB interface 1.9.2.1 USB features SARA-R4 series modules include a High-Speed USB 2.0 compliant interface with 480 Mb/s maximum data rate, representing the main interface for transferring high speed data with a host application processor, supporting: AT command mode Data mode and Online command mode2 FW upgrades by means of the FOAT feature (see 1.12.7) FW upgrades by means of the u-blox dedicated tool Trace log capture (diagnostic purpose) The module itself acts as a USB device and can be connected to a USB host such as a Personal Computer or an embedded application microprocessor equipped with compatible drivers. The USB_D+/USB_D- lines carry USB serial bus data and signaling according to the Universal Serial Bus Revision 2.0 specification [4], while the VUSB_DET input pin senses the VBUS USB supply presence (nominally 5 V at the source) to detect the host connection and enable the interface. Neither the USB interface, nor the whole module is supplied by the VUSB_DET input, which senses the USB supply voltage and absorbs few microamperes. The USB interface is available as AT command / data communication interface only if an external valid USB VBUS supply voltage (5.0 V typical) is applied at the VUSB_DET input of the module since the switch-on of the module, and then held during normal operations. In this case, the UART will be not available. The USB interface is controlled and operated with: AT commands according to 3GPP TS 27.007 [6], 3GPP TS 27.005 [7] u-blox AT commands (for the complete list and syntax see SARA-R4 series AT Commands Manual [2]) For the definition of the interface data mode, command mode and online command mode see SARA-R4 series AT Commands Manual [2] UBX-16029218 - R03 System description Page 25 of 94 SARA-R4 series - System Integration Manual The USB interface of SARA-R4 series modules can provide the following USB functions: AT commands and data communication Diagnostic log The USB profile of SARA-R4 series modules identifies itself by the following VID (Vendor ID) and PID (Product ID) combination, included in the USB device descriptor according to the USB 2.0 specifications [4]. VID = 0x05C6 PID = 0x90B2 1.9.3 DDC (I2C) interface The I C interface is not supported by “00” and “01” product versions. 1.10 General Purpose Input/Output SARA-R4 series modules include six pins (GPIO1-GPIO6) which can be configured as General Purpose Input/Output or to provide custom functions via u-blox AT commands (for more details see the SARA-R4 series AT Commands Manual [2], +UGPIOC, +UGPIOR, +UGPIOW AT commands), as summarized in Table 8. Function Description Default GPIO Network status indication Network status: registered / data transmission, no service -- SIM card detection SIM card physical presence detection GPIO5 Module status indication Module switched off or in PSM low power deep sleep mode, versus active or connected mode -- General purpose input Input to sense high or low digital level -- General purpose output Output to set the high or the low digital level GPIO4 Pin disabled Tri-state with an internal active pull-down enabled GPIO1, GPIO2, GPIO3, GPIO6 Table 8: SARA-R4 series GPIO custom functions configuration 1.11 Reserved pins (RSVD) SARA-R4 series modules have pins reserved for future use, marked as RSVD: they can all be left unconnected on the application board. UBX-16029218 - R03 System description Page 26 of 94 SARA-R4 series - System Integration Manual 1.12 System features 1.12.1 Network indication GPIOs can be configured by the AT command to indicate network status (for further details see section 1.10 and the SARA-R4 series AT Commands Manual [2]): No service (no network coverage or not registered) Registered / Data call enabled (RF data transmission / reception) 1.12.2 Antenna supervisor The antenna detection function provided by the ANT_DET pin is based on an ADC measurement as optional feature that can be implemented if the application requires it. The antenna supervisor is forced by the +UANTR AT command (see the SARA-R4 series AT Commands Manual [2] for more details). The requirements to achieve antenna detection functionality are the following: an RF antenna assembly with a built-in resistor (diagnostic circuit) must be used an antenna detection circuit must be implemented on the application board See section 1.7.2 for detailed antenna detection interface functional description and see section 2.4.2 for detection circuit on application board and diagnostic circuit on antenna assembly design-in guidelines. 1.12.3 Dual stack IPv4/IPv6 SARA-R4 series support both Internet Protocol version 4 and Internet Protocol version 6 in parallel. For more details about dual stack IPv4/IPv6 see the SARA-R4 series AT Commands Manual [2]. 1.12.4 TCP/IP and UDP/IP SARA-R4 series modules provide embedded TCP/IP and UDP/IP protocol stack: a PDP context can be configured established and handled via the data connection management packet switched data commands. SARA-R4 series modules provide Direct Link mode to establish a transparent end-to-end communication with an already connected TCP or UDP socket via serial interfaces (USB, UART). In Direct Link mode, data sent to the serial interface from an external application processor is forwarded to the network and vice-versa. For more details on embedded TCP/IP and UDP/IP functionalities see SARA-R4 series AT Commands Manual [2]. 1.12.5 FTP SARA-R4 series provide embedded File Transfer Protocol (FTP) services. Files are read and stored in the local file system of the module. FTP files can also be transferred using FTP Direct Link: FTP download: data coming from the FTP server is forwarded to the host processor via USB / UART serial interfaces (for FTP without Direct Link mode the data is always stored in the module’s Flash File System) FTP upload: data coming from the host processor via USB / UART serial interface is forwarded to the FTP server (for FTP without Direct Link mode the data is read from the module’s Flash File System) When Direct Link is used for a FTP file transfer, only the file content pass through USB / UART serial interface, whereas all the FTP commands handling is managed internally by the FTP application. For more details about embedded FTP functionalities see SARA-R4 series AT Commands Manual [2]. UBX-16029218 - R03 System description Page 27 of 94 SARA-R4 series - System Integration Manual 1.12.6 HTTP SARA-R4 series modules provide the embedded Hyper-Text Transfer Protocol (HTTP) services via AT commands for sending requests to a remote HTTP server, receiving the server response and transparently storing it in the module’s Flash File System (FFS). For more details about embedded HTTP functionalities see the SARA-R4 series AT Commands Manual [2]. 1.12.7 Firmware update Over AT (FOAT) This feature allows upgrading of the module firmware over the AT interface, using AT commands. The +UFWUPD AT command enables a code download to the device from the host via the Xmodem protocol. The +UFWINSTALL AT command then triggers a reboot, and upon reboot initiates a firmware installation on the device via a special boot loader on the module. The bootloader first authenticates the downloaded image, then installs it, and then reboots the module. Firmware authenticity verification is performed via a security signature. The firmware is then installed, overwriting the current version. In case of power loss during this phase, the boot loader detects a fault at the next wake-up, and restarts the firmware installation. After completing the upgrade, the module is reset again and wakes-up in normal boot. For more details about Firmware update Over AT procedure, see the SARA-R4 series AT Commands Manual [2], +UFWUPD AT command. 1.12.8 Firmware update Over The Air (FOTA) This feature allows upgrading the module firmware over the air interface. For more details about Firmware update Over The Air procedure see SARA-R4 series AT Commands Manual [2], +UFWINSTALL AT command. 1.12.9 Power saving The power saving configuration is by default disabled, but it can be enabled using the AT+CPSMS command (for the complete description of the AT+CPSMS command, see the SARA-R4 series AT Commands Manual [2]). When power saving is enabled, the module automatically enters the low power deep sleep mode whenever possible, reducing current consumption (see section 1.5.1.3 and SARA-R4 series Data Sheet [1]). For the definition and the description of SARA-R4 series modules operating modes, including the events forcing transitions between the different operating modes, see the section 1.4. 1.12.9.1 Functionality The SARA-R4 series modules achieve the low power deep sleep mode by powering down all the Hardware components with the exception of the 32 kHz reference internally generated. From the host application point of view, the USB/UART ports will not be available during low power deep sleep mode, as the SARA-R4 module will act as if the SARA-R4 module is in Power-Off mode. 1.12.9.2 Timers and Network Interaction The SARA-R4 series modules goes in low power deep sleep mode entering in the Power Saving Mode (PSM) defined in 3GPP Release 13. Two timers have been specified on the PSM Signaling: the “Periodic Update Timer” and “Active Timer”. The “Active Timer” is the time defined by the network where the SARA-R4 series module will keep listening for any active operation, during this time the SARA-R4 series module is in Active mode. UBX-16029218 - R03 System description Page 28 of 94 SARA-R4 series - System Integration Manual The “Periodic Update Timer” is the Extended Tracking Area Update (TAU) used by the SARA-R4 series module to periodically notify the network of its availability. The SARA-R4 series module requests the PSM by including the “Active Timer” with the desired value in the Attach, TAU or Routing Area Update (RAU) messages. The “Active Timer” is the time the module listens to the Paging Channel after having transitioned from connected to active mode. When the “Active Timer” expires, the module enters PSM low power deep sleep mode. SARA-R4 series module can also request an extended “Periodic Update Timer” value to remain in PSM low power deep sleep mode for longer than the original “Periodic Update Timer” broadcasted by the network. The grant of PSM is a negotiation between SARA-R4 series module and the attached network: the network accepts PSM by providing the actual value of the “Active Timer” (and “Periodic Update Timer”) to be used in the Attach/TAU/RAU accept procedure. The maximum duration, including “Periodic Update Timer”, is about 413 days. The SARA-R4 series module enters PSM low power deep sleep mode only after “Active Timer” expires. Current Connected mode: Data Tx / Rx PSM low power deep sleep mode Active mode (periodic update timer) (active timer) Time Figure 9: Description of the PSM timing 1.12.9.3 AT Commands The module uses the +CPSMS AT command with its defined parameters to request PSM timers to the network. See the SARA-R4 series AT Commands Manual [2] for details of the +CPSMS operation and features. 1.12.9.4 Host Application The PSM low power deep sleep mode implementation allows the SARA-R4 series module to help extend the battery life of the application. The Host Application should be aware the SARA-R4 series module is PSM capable. The host application needs to configure any available GPIO by means of AT commands (refer to GPIO section of SARA-R4 series AT Commands Manual [2]) to get the notification when the module has entered into PSM low power deep sleep mode. If the host application receives an event that needs to be reported by the SARA-R4 series module interrupting the PSM low power deep sleep mode, it can be done so by setting the module into Active mode using the appropriate power-on event (see 1.6.1). From the host application point of view, the SARA-R4 module will look as it is in Power-Off mode. 1.12.9.5 Normal Operation The Host Application can force the SARA-R4 series module to transition from PSM low power deep sleep mode to Active mode by using the Power Up procedure specified in section 1.6.1. Host application should be aware that transitioning from low power deep sleep mode to active mode will make the SARA-R4 series module to consume same amount of power as in Active-Mode shortening the battery life of the host application. UBX-16029218 - R03 System description Page 29 of 94 SARA-R4 series - System Integration Manual 2 Design-in 2.1 Overview For an optimal integration of SARA-R4 series modules in the final application board follow the design guidelines stated in this section. Every application circuit must be properly designed to guarantee the correct functionality of the relative interface, however a number of points require high attention during the design of the application device. The following list provides a rank of importance in the application design, starting from the highest relevance: 1. Module antenna connection: ANT and ANT_DET pins. Antenna circuit directly affects the RF compliance of the device integrating a SARA-R4 series module with applicable certification schemes. Follow the suggestions provided in the relative section 2.4 for schematic and layout design. 2. Module supply: VCC and GND pins. The supply circuit affects the RF compliance of the device integrating a SARA-R4 series module with applicable required certification schemes as well as antenna circuit design. Very carefully follow the suggestions provided in the relative section 2.2.1 for schematic and layout design. 3. USB interface: USB_D+, USB_D- and VUSB_DET pins. Accurate design is required to guarantee USB 2.0 high-speed interface functionality. Carefully follow the suggestions provided in the relative section 2.6.2 for schematic and layout design. 4. SIM interface: VSIM, SIM_CLK, SIM_IO, SIM_RST pins. Accurate design is required to guarantee SIM card functionality reducing the risk of RF coupling. Carefully follow the suggestions provided in the relative section 2.5 for schematic and layout design. 5. System functions: RESET_N , PWR_ON pins. Accurate design is required to guarantee that the voltage level is well defined during operation. Carefully follow the suggestions provided in the relative section 2.3 for schematic and layout design. 6. Other digital interfaces: UART, I C, GPIOs and Reserved pins. Accurate design is required to guarantee proper functionality and reduce the risk of digital data frequency harmonics coupling. Follow the suggestions provided in sections 2.6.1, 2.6.2, 2.6.3, 2.7 and 2.8 for schematic and layout design. 7. Other supplies: V_INT generic digital interfaces supply. Accurate design is required to guarantee proper functionality. Follow the suggestions provided in the corresponding section 2.2.2 for schematic and layout design. It is recommended to follow the specific design guidelines provided by each manufacturer of any external part selected for the application board integrating the u-blox cellular modules. UBX-16029218 - R03 Design-in Page 30 of 94 SARA-R4 series - System Integration Manual 2.2 Supply interfaces 2.2.1 Module supply (VCC) 2.2.1.1 General guidelines for VCC supply circuit selection and design All the available VCC pins have to be connected to the external supply minimizing the power loss due to series resistance. GND pins are internally connected. Application design shall connect all the available pads to solid ground on the application board, since a good (low impedance) connection to external ground can minimize power loss and improve RF and thermal performance. SARA-R4 series modules must be sourced through the VCC pins with a proper DC power supply that should meet the following prerequisites to comply with the modules’ VCC requirements summarized in Table 6. The proper DC power supply can be selected according to the application requirements (see Figure 10) between the different possible supply sources types, which most common ones are the following: Switching regulator Low Drop-Out (LDO) linear regulator Rechargeable Lithium-ion (Li-Ion) or Lithium-ion polymer (Li-Pol) battery Primary (disposable) battery Main Supply Available? No, portable device Battery Li-Ion 3.7 V Yes, always available Main Supply Voltage > 5V? No, less than 5 V Yes, greater than 5 V Linear LDO Regulator Switching Step-Down Regulator Figure 10: VCC supply concept selection The switching step-down regulator is the typical choice when the available primary supply source has a nominal voltage much higher (e.g. greater than 5 V) than the operating supply voltage of SARA-R4 series. The use of switching step-down provides the best power efficiency for the overall application and minimizes current drawn from the main supply source. See section 2.2.1.2 for specific design-in. The use of an LDO linear regulator becomes convenient for a primary supply with a relatively low voltage (e.g. less or equal than 5 V). In this case the typical 90% efficiency of the switching regulator diminishes the benefit of voltage step-down and no true advantage is gained in input current savings. On the opposite side, linear regulators are not recommended for high voltage step-down as they dissipate a considerable amount of energy in thermal power. See section 2.2.1.3 for specific design-in. If SARA-R4 series modules are deployed in a mobile unit where no permanent primary supply source is available, then a battery will be required to provide VCC. A standard 3-cell Li-Ion or Li-Pol battery pack directly connected to VCC is the usual choice for battery-powered devices. During charging, batteries with Ni-MH chemistry typically reach a maximum voltage that is above the maximum rating for VCC, and should therefore be avoided. See sections 2.2.1.4, 2.2.1.5, 2.2.1.7 and 2.2.1.8 for specific design-in. Keep in mind that the use of rechargeable batteries requires the implementation of a suitable charger circuit which is not included in the modules. The charger circuit has to be designed to prevent over-voltage on VCC pins, and it should be selected according to the application requirements: a DC/DC switching charger is the typical choice when the charging source has an high nominal voltage (e.g. ~12 V), whereas a linear charger is UBX-16029218 - R03 Design-in Page 31 of 94 SARA-R4 series - System Integration Manual the typical choice when the charging source has a relatively low nominal voltage (~5 V). If both a permanent primary supply / charging source (e.g. ~12 V) and a rechargeable back-up battery (e.g. 3.7 V Li-Pol) are available at the same time as possible supply source, then a proper charger / regulator with integrated power path management function can be selected to supply the module while simultaneously and independently charging the battery. See sections 2.2.1.7 and 2.2.1.8 for specific design-in. An appropriate primary (not rechargeable) battery can be selected taking into account the maximum current specified in SARA-R4 series Data Sheet [1] during connected-mode, considering that primary cells might have weak power capability. See section 2.2.1.5 for specific design-in. The usage of more than one DC supply at the same time should be carefully evaluated: depending on the supply source characteristics, different DC supply systems can result as mutually exclusive. The selected regulator or battery must be able to support with adequate margin the highest averaged current consumption value specified in the SARA-R4 series Data Sheet [1]. The following sections highlight some design aspects for each of the supplies listed above providing application circuit design-in compliant with the module VCC requirements summarized in Table 6. 2.2.1.2 Guidelines for VCC supply circuit design using a switching regulator The use of a switching regulator is suggested when the difference from the available supply rail source to the VCC value is high, since switching regulators provide good efficiency transforming a 12 V or greater voltage supply to the typical 3.8 V value of the VCC supply. The characteristics of the switching regulator connected to VCC pins should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6: Power capability: the switching regulator with its output circuit must be capable of providing a voltage value to the VCC pins within the specified operating range and must be capable of delivering to VCC pins the maximum current consumption occurring during transmissions at the maximum power, as specified in the SARA-R4 series Data Sheet [1]. Low output ripple: the switching regulator together with its output circuit must be capable of providing a clean (low noise) VCC voltage profile. High switching frequency: for best performance and for smaller applications it is recommended to select a switching frequency ≥ 600 kHz (since L-C output filter is typically smaller for high switching frequency). The use of a switching regulator with a variable switching frequency or with a switching frequency lower than 600 kHz must be carefully evaluated since this can produce noise in the VCC voltage profile and therefore negatively impact the LTE modulation spectrum performance. PWM mode operation: it is preferable to select regulators with Pulse Width Modulation (PWM) mode. While in connected-mode, the Pulse Frequency Modulation (PFM) mode and PFM/PWM modes transitions must be avoided to reduce noise on VCC voltage profile. Switching regulators can be used that are able to switch between low ripple PWM mode and high ripple PFM mode, provided that the mode transition occurs when the module changes status from the active-mode to connected-mode. It is permissible to use a regulator that switches from the PWM mode to the burst or PFM mode at an appropriate current threshold. UBX-16029218 - R03 Design-in Page 32 of 94 SARA-R4 series - System Integration Manual Figure 11 and Table 9 show an example of a high reliability power supply circuit, where the module VCC input is supplied by a step-down switching regulator capable of delivering maximum current with low output ripple and with fixed switching frequency in PWM mode operation greater than 1 MHz. 12V VCC 9 EN C1 C2 VSW 8 PG BST U1 SARA-R4 3V8 VCC VCC 53 VCC 51 52 L1 10 C3 D1 R1 C4 C6 C5 C7 C8 C9 FB 5 PGND 11 GND R2 GND Figure 11: Example of high reliability VCC supply application circuit using a step-down regulator Reference Description Part Number - Manufacturer C1 C2 10 µF Capacitor Ceramic X7R 50 V 10 nF Capacitor Ceramic X7R 16 V Generic manufacturer Generic manufacturer C3 C4 22 nF Capacitor Ceramic X7R 16 V 22 µF Capacitor Ceramic X5R 25 V Generic manufacturer Generic manufacturer C5 22 µF Capacitor Ceramic X5R 25 V Generic manufacturer C6 C7 15 pF Capacitor Ceramic C0G 0402 5% 50 V 68 pF Capacitor Ceramic C0G 0402 5% 50 V Generic manufacturer Generic manufacturer C8 C9 10 nF Capacitor Ceramic X7R 16 V 100 nF Capacitor Ceramic X7R 16 V Generic manufacturer Generic manufacturer D1 L1 Schottky Diode 30 V 2 A 4.7 µH Inductor 20% 2 A MBR230LSFT1G - ON Semiconductor SLF7045T-4R7M2R0-PF - TDK R1 470 k Resistor 0.1 W Generic manufacturer R2 150 k Resistor 0.1 W Step-Down Regulator 1 A 1 MHz Generic manufacturer U1 TS30041 - Semtech Table 9: Components for high reliability VCC supply application circuit using a step-down regulator UBX-16029218 - R03 Design-in Page 33 of 94 SARA-R4 series - System Integration Manual 2.2.1.3 Guidelines for VCC supply circuit design using a Low Drop-Out linear regulator The use of a linear regulator is suggested when the difference from the available supply rail source and the VCC value is low. The linear regulators provide high efficiency when transforming a 5 VDC supply to a voltage value within the module VCC normal operating range. The characteristics of the Low Drop-Out (LDO) linear regulator connected to VCC pins should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6: Power capabilities: the LDO linear regulator with its output circuit must be capable of providing a voltage value to the VCC pins within the specified operating range and must be capable of delivering to VCC pins the maximum current consumption occurring during a transmission at the maximum Tx power, as specified in SARA-R4 series Data Sheet [1]. Power dissipation: the power handling capability of the LDO linear regulator must be checked to limit its junction temperature to the maximum rated operating range (i.e. check the voltage drop from the max input voltage to the minimum output voltage to evaluate the power dissipation of the regulator). Figure 12 and the components listed in Table 10 show an example of a power supply circuit, where the VCC module supply is provided by an LDO linear regulator capable of delivering the required current, with proper power handling capability. It is recommended to configure the LDO linear regulator to generate a voltage supply value slightly below the maximum limit of the module VCC normal operating range (e.g. ~4.1 V for the VCC, as in the circuits described in Figure 12 and Table 10). This reduces the power on the linear regulator and improves the thermal design of the circuit. SARA-R4 series 5V IN OUT 51 52 53 U1 C1 R1 ADJ EN GND R2 C2 C3 R3 C4 C5 VCC VCC VCC C6 GND Figure 12: Example of high reliability VCC supply application circuit using an LDO linear regulator Reference Description Part Number - Manufacturer C1 C2 1 µF Capacitor Ceramic X5R 6.3 V 22 µF Capacitor Ceramic X5R 25 V Generic manufacturer Generic manufacturer C3 C4 15 pF Capacitor Ceramic C0G 50 V 68 pF Capacitor Ceramic C0G 50 V Generic manufacturer Generic manufacturer C5 C6 10 nF Capacitor Ceramic X7R 16 V 100 nF Capacitor Ceramic X7R 16 V Generic manufacturer Generic manufacturer R1 47 k Resistor 0.1 W Generic manufacturer R2 41 k Resistor 0.1 W Generic manufacturer R3 10 k Resistor 0.1 W Generic manufacturer U1 LDO Linear Regulator 1.0 A AP7361 – Diodes Incorporated Table 10: Components for high reliability VCC supply application circuit using an LDO linear regulator UBX-16029218 - R03 Design-in Page 34 of 94 SARA-R4 series - System Integration Manual 2.2.1.4 Guidelines for VCC supply circuit design using a rechargeable Li-Ion or Li-Pol battery Rechargeable Li-Ion or Li-Pol batteries connected to the VCC pins should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6: Maximum pulse and DC discharge current: the rechargeable Li-Ion battery with its related output circuit connected to the VCC pins must be capable of delivering the maximum current occurring during a transmission at maximum Tx power, as specified in SARA-R4 series Data Sheet [1]. The maximum discharge current is not always reported in the data sheets of batteries, but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour. DC series resistance: the rechargeable Li-Ion battery with its output circuit must be capable of avoiding a VCC voltage drop below the operating range summarized in Table 6 during transmit bursts. 2.2.1.5 Guidelines for VCC supply circuit design using a primary (disposable) battery The characteristics of a primary (non-rechargeable) battery connected to VCC pins should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6: Maximum pulse and DC discharge current: the non-rechargeable battery with its related output circuit connected to the VCC pins must be capable of delivering the maximum current consumption occurring during a transmission at maximum Tx power, as specified in SARA-R4 series Data Sheet [1]. The maximum discharge current is not always reported in the data sheets of batteries, but the max DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour. DC series resistance: the non-rechargeable battery with its output circuit must be capable of avoiding a VCC voltage drop below the operating range summarized in Table 6 during transmit bursts. 2.2.1.6 Additional guidelines for VCC supply circuit design To reduce voltage drops, use a low impedance power source. The series resistance of the power supply lines (connected to the modules’ VCC and GND pins) on the application board and battery pack should also be considered and minimized: cabling and routing must be as short as possible to minimize power losses. Three pins are allocated to VCC supply. Several pins are designated for GND connection. It is recommended to properly connect all of them to supply the module to minimize series resistance losses. To reduce voltage ripple and noise, improving RF performance especially if the application device integrates an internal antenna, place the following bypass capacitors near the VCC pins: 68 pF capacitor with Self-Resonant Frequency in the 800/900 MHz range (e.g. Murata GRM1555C1H680J), to filter EMI in the low cellular frequency bands 15 pF capacitor with Self-Resonant Frequency in the 1800/1900 MHz range (as Murata GRM1555C1H150J), to filter EMI in the high cellular frequency bands 10 nF capacitor (e.g. Murata GRM155R71C103K), to filter digital logic noise from clocks and data sources 100 nF capacitor (e.g. Murata GRM155R61C104K), to filter digital logic noise from clocks and data sources 10 µF capacitor (or greater), to avoid undershoot and overshoot at the start and end of RF Tx A suitable series ferrite bead can be properly placed on the VCC line for additional noise filtering if required by the specific application according to the whole application board design. UBX-16029218 - R03 Design-in Page 35 of 94 SARA-R4 series - System Integration Manual SARA-R4 series 3V8 VCC 51 VCC 52 VCC 53 C1 C2 C3 C4 C5 GND Figure 13: Suggested schematic for the VCC bypass capacitors to reduce ripple / noise on supply voltage profile Reference Description Part Number - Manufacturer C1 C2 68 pF Capacitor Ceramic C0G 0402 5% 50 V 15 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H680JA01 - Murata GRM1555C1H150JA01 - Murata C3 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C103KA01 - Murata C4 C5 100 nF Capacitor Ceramic X7R 0402 10% 16 V 10 µF Capacitor Ceramic X5R 0603 20% 6.3 V GRM155R71C104KA01 - Murata GRM188R60J106ME47 - Murata Table 11: Suggested components to reduce ripple / noise on VCC The necessity of each part depends on the specific design, but it is recommended to provide all the bypass capacitors described in Figure 13 / Table 11 if the application device integrates an internal antenna. ESD sensitivity rating of the VCC supply pins is 1 kV (HBM according to JESD22-A114). Higher protection level can be required if the line is externally accessible on the application board, e.g. if accessible battery connector is directly connected to the supply pins. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor) close to accessible point. 2.2.1.7 Guidelines for external battery charging circuit SARA-R4 series modules do not have an on-board charging circuit. Figure 14 provides an example of a battery charger design, suitable for applications that are battery powered with a Li-Ion (or Li-Polymer) cell. In the application circuit, a rechargeable Li-Ion (or Li-Polymer) battery cell, that features proper pulse and DC discharge current capabilities and proper DC series resistance, is directly connected to the VCC supply input of the module. Battery charging is completely managed by the Battery Charger IC that, from a USB power source (5.0 V typ.), charges as a linear charger the battery, in three phases: Pre-charge constant current (active when the battery is deeply discharged): the battery is charged with a low current Fast-charge constant current: the battery is charged with the maximum current, configured by the value of an external resistor Constant voltage: when the battery voltage reaches the regulated output voltage, the Battery Charger IC starts to reduce the current until the charge termination is done. The charging process ends when the charging current reaches the value configured by an external resistor or when the charging timer reaches the factory set value Using a battery pack with an internal NTC resistor, the Battery Charger IC can monitor the battery temperature to protect the battery from operating under unsafe thermal conditions. The Battery Charger IC, as linear charger, is more suitable for applications where the charging source has a relatively low nominal voltage (~5 V), so that a switching charger is suggested for applications where the charging source has a relatively high nominal voltage (e.g. ~12 V, see the following section 2.2.1.8 for specific design-in). UBX-16029218 - R03 Design-in Page 36 of 94 SARA-R4 series - System Integration Manual Li-Ion/Li-Polymer Battery Charger IC SARA-R4 series 5V0 USB Supply VDD Vbat C2 PG 51 VCC 52 VCC 53 VCC Li-Ion/Li-Pol Battery Pack THERM C1 θ STAT2 PROG C3 C4 C5 C6 R1 STA1 Vss B1 D1 GND D2 U1 Figure 14: Li-Ion (or Li-Polymer) battery charging application circuit Reference Description Part Number - Manufacturer B1 Li-Ion (or Li-Polymer) battery pack with 470 NTC Generic manufacturer C1, C2 C3 1 µF Capacitor Ceramic X7R 16 V 15 pF Capacitor Ceramic C0G 0402 5% 50 V Generic manufacturer GRM1555C1H150JA01 - Murata C4 68 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H680JA01 - Murata C5 C6 10 nF Capacitor Ceramic X7R 0402 10% 16 V 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C103KA01 - Murata GRM155R71C104KA01 - Murata D1, D2 R1 Low Capacitance ESD Protection 10 k Resistor 0.1 W CG0402MLE-18G - Bourns Generic manufacturer U1 Single Cell Li-Ion (or Li-Polymer) Battery Charger IC MCP73833 - Microchip Table 12: Suggested components for Li-Ion (or Li-Polymer) battery charging application circuit 2.2.1.8 Guidelines for external battery charging and power path management circuit Application devices where both a permanent primary supply / charging source (e.g. ~12 V) and a rechargeable back-up battery (e.g. 3.7 V Li-Pol) are available at the same time as possible supply source should implement a suitable charger / regulator with integrated power path management function to supply the module and the whole device while simultaneously and independently charging the battery. Figure 15 reports a simplified block diagram circuit showing the working principle of a charger / regulator with integrated power path management function. This component allows the system to be powered by a permanent primary supply source (e.g. ~12 V) using the integrated regulator which simultaneously and independently recharges the battery (e.g. 3.7 V Li-Pol) that represents the back-up supply source of the system: the power path management feature permits the battery to supplement the system current requirements when the primary supply source is not available or cannot deliver the peak system currents. A power management IC should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6: High efficiency internal step down converter, compliant with the performances specified in section 2.2.1.2 Low internal resistance in the active path Vout – Vbat, typically lower than 50 m High efficiency switch mode charger with separate power path control UBX-16029218 - R03 Design-in Page 37 of 94 SARA-R4 series - System Integration Manual Power path management IC 12 V Primary Source Vin System Vout DC/DC converter and battery FET control logic Vbat Li-Ion/Li-Pol Battery Pack Charge controller GND GND θ Figure 15: Charger / regulator with integrated power path management circuit block diagram Figure 16 and the components listed in Table 13 provide an application circuit example where the MPS MP2617 switching charger / regulator with integrated power path management function provides the supply to the cellular module while concurrently and autonomously charging a suitable Li-Ion (or Li-Polymer) battery with proper pulse and DC discharge current capabilities and proper DC series resistance according to the rechargeable battery recommendations described in section 2.2.1.4. The MP2617 IC constantly monitors the battery voltage and selects whether to use the external main primary supply / charging source or the battery as supply source for the module, and starts a charging phase accordingly. The MP2617 IC normally provides a supply voltage to the module regulated from the external main primary source allowing immediate system operation even under missing or deeply discharged battery: the integrated switching step-down regulator is capable to provide up to 3 A output current with low output ripple and fixed 1.6 MHz switching frequency in PWM mode operation. The module load is satisfied in priority, then the integrated switching charger will take the remaining current to charge the battery. Additionally, the power path control allows an internal connection from battery to the module with a low series internal ON resistance (40 m typical), in order to supplement additional power to the module when the current demand increases over the external main primary source or when this external source is removed. Battery charging is managed in three phases: Pre-charge constant current (active when the battery is deeply discharged): the battery is charged with a low current, set to 10% of the fast-charge current Fast-charge constant current: the battery is charged with the maximum current, configured by the value of an external resistor to a value suitable for the application Constant voltage: when the battery voltage reaches the regulated output voltage (4.2 V), the current is progressively reduced until the charge termination is done. The charging process ends when the charging current reaches the 10% of the fast-charge current or when the charging timer reaches the value configured by an external capacitor Using a battery pack with an internal NTC resistor, the MP2617 can monitor the battery temperature to protect the battery from operating under unsafe thermal conditions. Several parameters as the charging current, the charging timings, the input current limit, the input voltage limit, the system output voltage can be easily set according to the specific application requirements, as the actual electrical characteristics of the battery and the external supply / charging source: proper resistors or capacitors have to be accordingly connected to the related pins of the IC. UBX-16029218 - R03 Design-in Page 38 of 94 SARA-R4 series - System Integration Manual Li-Ion/Li-Polymer Battery Charger / Regulator with Power Path Managment BST 12V L1 SW Primary Source VIN SARA-R4 series C4 53 VCC R4 C5 VLIM R5 Li-Ion/Li-Pol Battery Pack BAT R1 R2 EN ILIM NTC ISET VCC TMR C1 51 VCC 52 VCC SYS C2 AGND PGND C10 C11 C12 C13 C14 θ R3 C3 C6 C7 C8 GND D1 D2 B1 U1 Figure 16: Li-Ion (or Li-Polymer) battery charging and power path management application circuit Reference Description Part Number - Manufacturer B1 Li-Ion (or Li-Polymer) battery pack with 10 k NTC 22 µF Capacitor Ceramic X5R 1210 10% 25 V Various manufacturer C1, C5, C6 C2, C4, C11 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata C3 C7, C13 1 µF Capacitor Ceramic X7R 0603 10% 25 V 68 pF Capacitor Ceramic C0G 0402 5% 50 V GRM188R71E105KA12 - Murata GRM1555C1H680JA01 - Murata C8, C14 C10 15 pF Capacitor Ceramic C0G 0402 5% 25 V 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 m GRM1555C1E150JA01 - Murata T520D337M006ATE045 - KEMET C12 D1, D2 10 nF Capacitor Ceramic X7R 0402 10% 16 V Low Capacitance ESD Protection GRM155R71C103KA01 - Murata CG0402MLE-18G - Bourns R1, R3, R5 10 k Resistor 0402 5% 1/16 W RC0402JR-0710KL - Yageo Phycomp R2 1.0 k Resistor 0402 5% 0.1 W RC0402JR-071K0L - Yageo Phycomp R4 22 k Resistor 0402 5% 1/16 W RC0402JR-0722KL - Yageo Phycomp L1 1.2 µH Inductor 6 A 21 m 20% Li-Ion/Li-Polymer Battery DC/DC Charger / Regulator with integrated Power Path Management function 7447745012 - Wurth U1 GRM32ER61E226KE15 - Murata MP2617 - Monolithic Power Systems (MPS) Table 13: Suggested components for Li-Ion (or Li-Polymer) battery charging and power path management application circuit 2.2.1.9 Guidelines for VCC supply layout design Good connection of the module VCC pins with DC supply source is required for correct RF performance. Guidelines are summarized in the following list: All the available VCC pins must be connected to the DC source VCC connection must be as wide as possible and as short as possible Any series component with Equivalent Series Resistance (ESR) greater than few milliohms must be avoided VCC connection must be routed through a PCB area separated from RF lines / parts, sensitive analog signals and sensitive functional units: it is good practice to interpose at least one layer of PCB ground between the VCC track and other signal routing Coupling between VCC and digital lines, especially USB, must be avoided. The tank bypass capacitor with low ESR for current spikes smoothing described in section 2.2.1.6 should be placed close to the VCC pins. If the main DC source is a switching DC-DC converter, place the large capacitor close to the DC-DC output and minimize VCC track length. Otherwise consider using separate capacitors for DC-DC converter and module tank capacitor UBX-16029218 - R03 Design-in Page 39 of 94 SARA-R4 series - System Integration Manual The bypass capacitors in the pF range described in Figure 13 and Table 11 should be placed as close as possible to the VCC pins, where the VCC line narrows close to the module input pins, improving the RF noise rejection in the band centered on the Self-Resonant Frequency of the pF capacitors. This is highly recommended if the application device integrates an internal antenna Since VCC input provide the supply to RF Power Amplifiers, voltage ripple at high frequency may result in unwanted spurious modulation of transmitter RF signal. This is more likely to happen with switching DC-DC converters, in which case it is better to select the highest operating frequency for the switcher and add a large L-C filter before connecting to the SARA-R4 series modules in the worst case Shielding of switching DC-DC converter circuit, or at least the use of shielded inductors for the switching DC-DC converter, may be considered since all switching power supplies may potentially generate interfering signals as a result of high-frequency high-power switching. If VCC is protected by transient voltage suppressor to ensure that the voltage maximum ratings are not exceeded, place the protecting device along the path from the DC source toward the module, preferably closer to the DC source (otherwise protection functionality may be compromised) 2.2.1.10 Guidelines for grounding layout design Good connection of the module GND pins with application board solid ground layer is required for correct RF performance. It significantly reduces EMC issues and provides a thermal heat sink for the module. Connect each GND pin with application board solid GND layer. It is strongly recommended that each GND pad surrounding VCC pins have one or more dedicated via down to the application board solid ground layer The VCC supply current flows back to main DC source through GND as ground current: provide adequate return path with suitable uninterrupted ground plane to main DC source It is recommended to implement one layer of the application board as ground plane as wide as possible If the application board is a multilayer PCB, then all the board layers should be filled with GND plane as much as possible and each GND area should be connected together with complete via stack down to the main ground layer of the board. Use as many vias as possible to connect the ground planes Provide a dense line of vias at the edges of each ground area, in particular along RF and high speed lines If the whole application device is composed by more than one PCB, then it is required to provide a good and solid ground connection between the GND areas of all the different PCBs Good grounding of GND pads also ensures thermal heat sink. This is critical during connection, when the real network commands the module to transmit at maximum power: proper grounding helps prevent module overheating. UBX-16029218 - R03 Design-in Page 40 of 94 SARA-R4 series - System Integration Manual 2.2.2 Generic digital interfaces supply output (V_INT) 2.2.2.1 Guidelines for V_INT circuit design SARA-R4 series provide the V_INT generic digital interfaces 1.8 V supply output, which can be mainly used to: Indicate when the module is switched on (as described in sections 1.6.1, 1.6.2) Pull-up SIM detection signal (see section 2.5 for more details) Supply voltage translators to connect 1.8 V module generic digital interfaces to 3.0 V devices (e.g. see 2.6.1) Enable external voltage regulators providing supply for external devices, Do not apply loads which might exceed the limit for maximum available current from V_INT supply (see the SARA-R4 series Data Sheet [1]) as this can cause malfunctions in internal circuitry. V_INT can only be used as an output: do not connect any external supply source on V_INT. ESD sensitivity rating of the V_INT supply pin is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the line is externally accessible and it can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to the accessible point. It is recommended to provide direct access to the V_INT pin on the application board by means of an accessible test point directly connected to the V_INT pin. UBX-16029218 - R03 Design-in Page 41 of 94 SARA-R4 series - System Integration Manual 2.3 System functions interfaces 2.3.1 Module power-on (PWR_ON) 2.3.1.1 Guidelines for PWR_ON circuit design SARA-R4 series PWR_ON input is equipped with an internal active pull-up resistor; an external pull-up resistor is not required and should not be provided. If connecting the PWR_ON input to a push button, the pin will be externally accessible on the application device. According to EMC/ESD requirements of the application, an additional ESD protection should be provided close to the accessible point, as described in Figure 17 and Table 14. ESD sensitivity rating of the PWR_ON pin is 1 kV (Human Body Model according to JESD22-A114). Higher protection level can be required if the line is externally accessible on the application board, e.g. if an accessible push button is directly connected to PWR_ON pin, and it can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor) close to the accessible point. An open drain or open collector output is suitable to drive the PWR_ON input from an application processor, as described in Figure 17.A compatible push-pull output of an application processor can also be used. In any case, take care to set the proper level in all the possible scenarios to avoid an inappropriate module switch on or switch off. SARA-R4 series Power-on push button TP Application Processor SARA-R4 series Open Drain Output 15 PWR_ON TP 15 PWR_ON ESD Figure 17: PWR_ON application circuits using a push button and an open drain output of an application processor Reference Description Remarks ESD CT0402S14AHSG - EPCOS Varistor array for ESD protection Table 14: Example ESD protection component for the PWR_ON application circuit It is recommended to provide direct access to the PWR_ON pin on the application board by means of an accessible test point directly connected to the PWR_ON pin. 2.3.1.2 Guidelines for PWR_ON layout design The power-on circuit (PWR_ON) requires careful layout since it is the sensitive input available to switch on and switch off the SARA-R4 series modules. It is required to ensure that the voltage level is well defined during operation and no transient noise is coupled on this line, otherwise the module might detect a spurious power-on request. UBX-16029218 - R03 Design-in Page 42 of 94 SARA-R4 series - System Integration Manual 2.3.2 Module reset (RESET_N) 2.3.2.1 Guidelines for RESET_N circuit design SARA-R4 series RESET_N is equipped with an internal pull-up; an external pull-up resistor is not required. If connecting the RESET_N input to a push button, the pin will be externally accessible on the application device. According to EMC/ESD requirements of the application, an additional ESD protection device (e.g. the EPCOS CA05P4S14THSG varistor) should be provided close to accessible point on the line connected to this pin, as described in Figure 18 and Table 15. ESD sensitivity rating of the RESET_N pin is 1 kV (HBM according to JESD22-A114). Higher protection level can be required if the line is externally accessible on the application board, e.g. if an accessible push button is directly connected to the RESET_N pin, and it can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor) close to accessible point. An open drain output is suitable to drive the RESET_N input from an application processor, as described in Figure 18. A compatible push-pull output of an application processor can also be used. In any case, take care to set the proper level in all the possible scenarios to avoid an inappropriate module switch off. SARA-R4 series Power-on push button TP Application Processor Open Drain Output 18 RESET_N SARA-R4 series TP 18 RESET_N ESD Figure 18: RESET_N application circuits using a push button and an open drain output of an application processor Reference Description Remarks ESD Varistor for ESD protection CT0402S14AHSG - EPCOS Table 15: Example of ESD protection component for the RESET_N application circuits If the external reset function is not required by the customer application, the RESET_N input pin can be left unconnected to external components, but it is recommended providing direct access on the application board by means of an accessible test point directly connected to the RESET_N pin. 2.3.2.2 Guidelines for RESET_N layout design The RESET_N circuit require careful layout due to the pin function: ensure that the voltage level is well defined during operation and no transient noise is coupled on this line, otherwise the module might detect a spurious reset request. It is recommended to keep the connection line to RESET_N pin as short as possible. UBX-16029218 - R03 Design-in Page 43 of 94 SARA-R4 series - System Integration Manual 2.4 Antenna interface SARA-R4 series modules provide an RF interface for connecting the external antenna: the ANT pin represents the RF input/output for RF signals transmission and reception. The ANT pin has a nominal characteristic impedance of 50 and must be connected to the physical antenna through a 50 transmission line to allow proper transmission / reception of RF signals. 2.4.1 Antenna RF interface (ANT) 2.4.1.1 General guidelines for antenna selection and design The antenna is the most critical component to be evaluated. Designers must take care of the antenna from all perspective at the very start of the design phase when the physical dimensions of the application board are under analysis/decision, since the RF compliance of the device integrating SARA-R4 series modules with all the applicable required certification schemes depends on antenna’s radiating performance. LTE antennas are typically available in the types of linear monopole or PCB antennas such as patches or ceramic SMT elements. External antennas (e.g. linear monopole) External antennas basically do not imply physical restriction to the design of the PCB where the SARA-R4 series module is mounted. The radiation performance mainly depends on the antennas. It is required to select antennas with optimal radiating performance in the operating bands. RF cables should be carefully selected to have minimum insertion losses. Additional insertion loss will be introduced by low quality or long cable. Large insertion loss reduces both transmit and receive radiation performance. A high quality 50 RF connector provides proper PCB-to-RF-cable transition. It is recommended to strictly follow the layout and cable termination guidelines provided by the connector manufacturer. Integrated antennas (e.g. patch-like antennas): o Internal integrated antennas imply physical restriction to the design of the PCB: Integrated antenna excites RF currents on its counterpoise, typically the PCB ground plane of the device that becomes part of the antenna: its dimension defines the minimum frequency that can be radiated. Therefore, the ground plane can be reduced down to a minimum size that should be similar to the quarter of the wavelength of the minimum frequency that has to be radiated, given that the orientation of the ground plane relative to the antenna element must be considered. As numerical example, the physical restriction to the PCB design can be considered as following: Frequency = 750 MHz Wavelength = 40 cm Minimum GND plane size = 10 cm Radiation performance depends on the whole PCB and antenna system design, including product mechanical design and usage. Antennas should be selected with optimal radiating performance in the operating bands according to the mechanical specifications of the PCB and the whole product. It is recommended to select a custom antenna designed by an antennas’ manufacturer if the required ground plane dimensions are very small (e.g. less than 6.5 cm long and 4 cm wide). The antenna design process should begin at the start of the whole product design process It is highly recommended to strictly follow the detailed and specific guidelines provided by the antenna manufacturer regarding correct installation and deployment of the antenna system, including PCB layout and matching circuitry Further to the custom PCB and product restrictions, antennas may require tuning to obtain the required performance for compliance with all the applicable required certification schemes. It is recommended to UBX-16029218 - R03 Design-in Page 44 of 94 SARA-R4 series - System Integration Manual consult the antenna manufacturer for the design-in guidelines for antenna matching relative to the custom application In both of cases, selecting external or internal antennas, these recommendations should be observed: Select an antenna providing optimal return loss (or V.S.W.R.) figure over all the operating frequencies. Select an antenna providing optimal efficiency figure over all the operating frequencies. Select an antenna providing appropriate gain figure (i.e. combined antenna directivity and efficiency figure) so that the electromagnetic field radiation intensity do not exceed the regulatory limits specified in some countries (e.g. by FCC in the United States, as reported in the section 4.2.2). 2.4.1.2 Guidelines for antenna RF interface design Guidelines for ANT pin RF connection design Proper transition between ANT pad and the application board PCB must be provided, implementing the following design-in guidelines for the layout of the application PCB close to the ANT pad: On a multilayer board, the whole layer stack below the RF connection should be free of digital lines Increase GND keep-out (i.e. clearance, a void area) around the ANT pad, on the top layer of the application PCB, to at least 250 µm up to adjacent pads metal definition and up to 400 µm on the area below the module, to reduce parasitic capacitance to ground, as described in the left picture in Figure 19 Add GND keep-out (i.e. clearance, a void area) on the buried metal layer below the ANT pad if the top-layer to buried layer dielectric thickness is below 200 µm, to reduce parasitic capacitance to ground, as described in the right picture in Figure 19 GND clearance on top layer around ANT pad GND clearance on very close buried layer below ANT pad Min. 250 µm ANT Min. 400 µm GND Figure 19: GND keep-out area on top layer around ANT pad and on very close buried layer below ANT pad Guidelines for RF transmission line design Any RF transmission line, such as the ones from the ANT pad up to the related antenna connector or up to the related internal antenna pad, must be designed so that the characteristic impedance is as close as possible to 50 . RF transmission lines can be designed as a micro strip (consists of a conducting strip separated from a ground plane by a dielectric material) or a strip line (consists of a flat strip of metal which is sandwiched between two parallel ground planes within a dielectric material). The micro strip, implemented as a coplanar waveguide, is the most common configuration for printed circuit board. UBX-16029218 - R03 Design-in Page 45 of 94 SARA-R4 series - System Integration Manual Figure 20 and Figure 21 provide two examples of proper 50 coplanar waveguide designs. The first example of RF transmission line can be implemented in case of 4-layer PCB stack-up herein described, and the second example of RF transmission line can be implemented in case of 2-layer PCB stack-up herein described. 500 µm 380 µm 500 µm L1 Copper 35 µm FR-4 dielectric 270 µm L2 Copper 35 µm FR-4 dielectric 760 µm L3 Copper 35 µm FR-4 dielectric 270 µm L4 Copper 35 µm Figure 20: Example of 50 coplanar waveguide transmission line design for the described 4-layer board layup 400 µm 1200 µm 400 µm L1 Copper 35 µm FR-4 dielectric 1510 µm L2 Copper 35 µm Figure 21: Example of 50 coplanar waveguide transmission line design for the described 2-layer board layup If the two examples do not match the application PCB stack-up the 50 characteristic impedance calculation can be made using the HFSS commercial finite element method solver for electromagnetic structures from Ansys Corporation, or using freeware tools like AppCAD from Agilent (www.agilent.com) or TXLine from Applied Wave Research (www.mwoffice.com), taking care of the approximation formulas used by the tools for the impedance computation. To achieve a 50 characteristic impedance, the width of the transmission line must be chosen depending on: the thickness of the transmission line itself (e.g. 35 µm in the example of Figure 20 and Figure 21) the thickness of the dielectric material between the top layer (where the transmission line is routed) and the inner closer layer implementing the ground plane (e.g. 270 µm in Figure 20, 1510 µm in Figure 21) the dielectric constant of the dielectric material (e.g. dielectric constant of the FR-4 dielectric material in Figure 20 and Figure 21) the gap from the transmission line to the adjacent ground plane on the same layer of the transmission line (e.g. 500 µm in Figure 20, 400 µm in Figure 21) If the distance between the transmission line and the adjacent GND area (on the same layer) does not exceed 5 times the track width of the micro strip, use the “Coplanar Waveguide” model for the 50 calculation. UBX-16029218 - R03 Design-in Page 46 of 94 SARA-R4 series - System Integration Manual Additionally to the 50 impedance, the following guidelines are recommended for transmission lines design: Minimize the transmission line length: the insertion loss should be minimized as much as possible, in the order of a few tenths of a dB, Add GND keep-out (i.e. clearance, a void area) on buried metal layers below any pad of component present on the RF transmission lines, if top-layer to buried layer dielectric thickness is below 200 µm, to reduce parasitic capacitance to ground, The transmission lines width and spacing to GND must be uniform and routed as smoothly as possible: avoid abrupt changes of width and spacing to GND, Add GND stitching vias around transmission lines, as described in Figure 22, Ensure solid metal connection of the adjacent metal layer on the PCB stack-up to main ground layer, providing enough vias on the adjacent metal layer, as described in Figure 22, Route RF transmission lines far from any noise source (as switching supplies and digital lines) and from any sensitive circuit (as USB), Avoid stubs on the transmission lines, Avoid signal routing in parallel to transmission lines or crossing the transmission lines on buried metal layer, Do not route microstrip lines below discrete component or other mechanics placed on top layer An example of proper RF circuit design is reported in Figure 22. In this case, the ANT pin is directly connected to SMA connectors by means of proper 50 transmission lines, designed with proper layout. SARA module SMA connector Figure 22: Example of circuit and layout for antenna RF circuits on application board Guidelines for RF termination design The RF termination must provide a characteristic impedance of 50 as well as the RF transmission line up to the RF termination, to match the characteristic impedance of the ANT port. However, real antennas do not have perfect 50 load on all the supported frequency bands. Therefore, to reduce as much as possible performance degradation due to antennas mismatch, the RF termination must provide optimal return loss (or V.S.W.R.) figure over all the operating frequencies, as summarized in Table 7. UBX-16029218 - R03 Design-in Page 47 of 94 SARA-R4 series - System Integration Manual If an external antenna is used, the antenna connector represents the RF termination on the PCB: Use suitable a 50 connector providing proper PCB-to-RF-cable transition. Strictly follow the connector manufacturer’s recommended layout, for example: o SMA Pin-Through-Hole connectors require GND keep-out (i.e. clearance, a void area) on all the layers around the central pin up to annular pads of the four GND posts, as shown in Figure 22 U.FL surface mounted connectors require no conductive traces (i.e. clearance, a void area) in the area below the connector between the GND land pads. Cut out the GND layer under the RF connector and close to buried vias, to remove stray capacitance and thus keep the RF line 50 , e.g. the active pad of UFL connector needs to have a GND keep-out (i.e. clearance, a void area) at least on first inner layer to reduce parasitic capacitance to ground. If an integrated antenna is used, the RF terminations are represented by the integrated antenna. The following guidelines should be followed: Use an antenna designed by an antenna manufacturer, providing the best possible return loss (or V.S.W.R.). Provide a ground plane large enough according to the relative integrated antenna requirements. The ground plane of the application PCB can be reduced down to a minimum size that must be similar to one quarter of wavelength of the minimum frequency that has to be radiated. As numerical example, Frequency = 750 MHz Wavelength = 40 cm Minimum GND plane size = 10 cm It is highly recommended to strictly follow the detailed and specific guidelines provided by the antenna manufacturer regarding correct installation and deployment of the antenna system, including PCB layout and matching circuitry. Further to the custom PCB and product restrictions, the antenna may require a tuning to comply with all the applicable required certification schemes. It is recommended to consult the antenna manufacturer for the design-in guidelines for the antenna matching relative to the custom application. Additionally, these recommendations regarding the antenna system placement must be followed: Do not place the antenna within closed metal case. Do not place the antenna in close vicinity to end user since the emitted radiation in human tissue is limited by regulatory requirements. Place the antenna far from sensitive analog systems or employ countermeasures to reduce EMC issues. Take care of interaction between co-located RF systems since the LTE transmitted power may interact or disturb the performance of companion systems. UBX-16029218 - R03 Design-in Page 48 of 94 SARA-R4 series - System Integration Manual Examples of antennas Table 16 lists some examples of possible internal on-board surface-mount antennas. Manufacturer Part Number Product Name Description Taoglas PA.710.A Warrior Taoglas PA.711.A Warrior II Taoglas PCS.06.A Havok Antenova SR4L002 Lucida GSM / WCDMA / LTE SMD Antenna 698..960 MHz, 1710..2170 MHz, 2300..2400 MHz, 2490..2690 MHz 40.0 x 6.0 x 5.0 mm GSM / WCDMA / LTE SMD Antenna Pairs with the Taoglas PA.710.A Warrior for LTE MIMO applications 698..960 MHz, 1710..2170 MHz, 2300..2400 MHz, 2490..2690 MHz 40.0 x 6.0 x 5.0 mm GSM / WCDMA / LTE SMD Antenna 698..960 MHz, 1710..2170 MHz, 2500..2690 MHz 42.0 x 10.0 x 3.0 mm GSM / WCDMA / LTE SMD Antenna 698..960 MHz, 1710..2170 MHz, 2300..2400 MHz, 2490..2690 MHz 35.0 x 8.5 x 3.2 mm Table 16: Examples of internal surface-mount antennas Table 17 lists some examples of possible internal off-board PCB-type antennas with cable and connector. Manufacturer Part Number Taoglas FXUB63.07.0150C Product Name Taoglas FXUB66.07.0150C Taoglas FXUB70.A.07.C.001 Ethertronics 5001537 Prestta EAD FSQS35241-UF-10 SQ7 Maximus Description GSM / WCDMA / LTE PCB Antenna with cable and U.FL 698..960 MHz, 1575.42 MHz, 1710..2170 MHz, 2400..2690 MHz 96.0 x 21.0 mm GSM / WCDMA / LTE PCB Antenna with cable and U.FL 698..960 MHz, 1390..1435 MHz, 1575.42 MHz, 1710..2170 MHz, 2400..2700 MHz, 3400..3600 MHz, 4800..6000 MHz 120.2 x 50.4 mm GSM / WCDMA / LTE PCB MIMO Antenna with cables and U.FL 698..960 MHz, 1575.42 MHz, 1710..2170 MHz, 2400..2690 MHz 182.2 x 21.2 mm GSM / WCDMA / LTE PCB Antenna with cable 698..960 MHz, 1710..2170 MHz, 2300..2400 MHz, 2500..2690 MHz 80.0 x 18.0 mm GSM / WCDMA / LTE PCB Antenna with cable and U.FL 690..960 MHz, 1710..2170 MHz, 2500..2700 MHz 110.0 x 21.0 mm Table 17: Examples of internal antennas with cable and connector UBX-16029218 - R03 Design-in Page 49 of 94 SARA-R4 series - System Integration Manual Table 18 lists some examples of possible external antennas. Manufacturer Part Number Product Name Description Taoglas GSA.8827.A.101111 Phoenix Taoglas TG.30.8112 Taoglas MA241.BI.001 GSM / WCDMA / LTE adhesive-mount antenna with cable and SMA(M) 698..960 MHz, 1575.42 MHz, 1710..2170 MHz, 2490..2690 MHz 105 x 30 x 7.7 mm GSM / WCDMA / LTE swivel dipole antenna with SMA(M) 698..960 MHz, 1575.42 MHz, 1710..2170 MHz, 2400..2700 MHz 148.6 x 49 x 10 mm GSM / WCDMA / LTE MIMO 2in1 adhesive-mount combination antenna waterproof IP67 rated with cable and SMA(M) 698..960 MHz, 1710..2170 MHz, 2400..2700 MHz 205.8 x 58 x 12.4 mm Laird Tech. TRA6927M3PW-001 Laird Tech. CMS69273 Laird Tech. OC69271-FNM Laird Tech. CMD69273-30NM Pulse Electronics WA700/2700SMA Genesis GSM / WCDMA / LTE screw-mount antenna with N-type(F) 698..960 MHz, 1710..2170 MHz, 2300..2700 MHz 83.8 x Ø 36.5 mm GSM / WCDMA / LTE ceiling-mount antenna with cable and N-type(F) 698..960 MHz, 1575.42 MHz, 1710..2700 MHz 86 x Ø 199 mm GSM / WCDMA / LTE pole-mount antenna with N-type(M) 698..960 MHz, 1710..2690 MHz 248 x Ø 24.5 mm GSM / WCDMA / LTE ceiling-mount MIMO antenna with cables & N-type(M) 698..960 MHz, 1710..2700 MHz 43.5 x Ø 218.7 mm GSM / WCDMA / LTE clip-mount MIMO antenna with cables and SMA(M) 698..960 MHz,1710..2700 MHz 149 x 127 x 5.1 mm Table 18: Examples of external antennas UBX-16029218 - R03 Design-in Page 50 of 94 SARA-R4 series - System Integration Manual 2.4.2 Antenna detection interface (ANT_DET) 2.4.2.1 Guidelines for ANT_DET circuit design Figure 23 and Table 19 describe the recommended schematic / components for the antenna detection circuit that must be provided on the application board and for the diagnostic circuit that must be provided on the antenna’s assembly to achieve primary and secondary antenna detection functionality. Diagnostic Circuit SARA-R4 series ANT 56 Z0 = 50 Ω C3 C2 L2 ANT_DET 62 R1 Z0 = 50 ohm Z0 = 50 Ω J1 Antenna Cable Radiating Element C4 L3 L1 R2 C1 D1 GND Application Board Antenna Assembly Figure 23: Suggested schematic for antenna detection circuit on application board and diagnostic circuit on antenna assembly Reference Description Part Number - Manufacturer C1 C2, 27 pF Capacitor Ceramic C0G 0402 5% 50 V 33 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H270J - Murata GRM1555C1H330J - Murata D1 L1 Very Low Capacitance ESD Protection 68 nH Multilayer Inductor 0402 (SRF ~1 GHz) PESD0402-140 - Tyco Electronics LQG15HS68NJ02 - Murata R1 10 k Resistor 0402 1% 0.063 W RK73H1ETTP1002F - KOA Speer J1, SMA Connector 50 Through Hole Jack SMA6251A1-3GT50G-50 - Amphenol C4 L3 22 pF Capacitor Ceramic C0G 0402 5% 25 V 68 nH Multilayer Inductor 0402 (SRF ~1 GHz) GRM1555C1H220J - Murata LQG15HS68NJ02 - Murata R2 15 k Resistor for Diagnostic Various Manufacturers Table 19: Suggested components for antenna detection circuit on application board and diagnostic circuit on antennas assembly The antenna detection circuit and diagnostic circuit suggested in Figure 23 and Table 19 are here explained: When antenna detection is forced by the +UANTR AT command, the ANT_DET pin generates a DC current measuring the resistance (R2) from the antenna connector (J1) provided on the application board to GND. DC blocking capacitors are needed at the ANT pin (C2) and at the antenna radiating element (C4) to decouple the DC current generated by the ANT_DET pin. Choke inductors with a Self Resonance Frequency (SRF) in the range of 1 GHz are needed in series at the ANT_DET pin (L1) and in series at the diagnostic resistor (L3), to avoid a reduction of the RF performance of the system, improving the RF isolation of the load resistor. Resistor on the ANT_DET path (R1) is needed for accurate measurements through the +UANTR AT command. It also acts as an ESD protection. Additional components (C1 and D1 in Figure 23) are needed at the ANT_DET pin as ESD protection. Additional high pass filter (C3 and L2 in Figure 23) is provided at the ANT pin as ESD immunity improvement The ANT pin must be connected to the antenna connector by means of a transmission line with nominal characteristics impedance as close as possible to 50 . UBX-16029218 - R03 Design-in Page 51 of 94 SARA-R4 series - System Integration Manual The DC impedance at RF port for some antennas may be a DC open (e.g. linear monopole) or a DC short to reference GND (e.g. PIFA antenna). For those antennas, without the diagnostic circuit of Figure 23, the measured DC resistance is always at the limits of the measurement range (respectively open or short), and there is no mean to distinguish between a defect on antenna path with similar characteristics (respectively: removal of linear antenna or RF cable shorted to GND for PIFA antenna). Furthermore, any other DC signal injected to the RF connection from ANT connector to radiating element will alter the measurement and produce invalid results for antenna detection. It is recommended to use an antenna with a built-in diagnostic resistor in the range from 5 k to 30 k to assure good antenna detection functionality and avoid a reduction of module RF performance. The choke inductor should exhibit a parallel Self Resonance Frequency (SRF) in the range of 1 GHz to improve the RF isolation of load resistor. For example: Consider an antenna with built-in DC load resistor of 15 k. Using the +UANTR AT command, the module reports the resistance value evaluated from the antenna connector provided on the application board to GND: Reported values close to the used diagnostic resistor nominal value (i.e. values from 13 k to 17 k if a 15 k diagnostic resistor is used) indicate that the antenna is properly connected. Values close to the measurement range maximum limit (approximately 50 k) or an open-circuit “over range” report (see SARA-R4 series AT Commands Manual [2]) means that that the antenna is not connected or the RF cable is broken. Reported values below the measurement range minimum limit (1 k) highlights a short to GND at antenna or along the RF cable. Measurement inside the valid measurement range and outside the expected range may indicate an improper connection, damaged antenna or wrong value of antenna load resistor for diagnostic. Reported value could differ from the real resistance value of the diagnostic resistor mounted inside the antenna assembly due to antenna cable length, antenna cable capacity and the used measurement method. If the antenna detection function is not required by the customer application, the ANT_DET pin can be left not connected and the ANT pin can be directly connected to the antenna connector by means of a 50 transmission line as described in Figure 22. 2.4.2.2 Guidelines for ANT_DET layout design The recommended layout for the antenna detection circuit to be provided on the application board to achieve the antenna detection functionality, implementing the recommended schematic described in Figure 23 and Table 19, is explained here: The ANT pin have to be connected to the antenna connector by means of a 50 transmission line, implementing the design guidelines described in section 2.4.1 and the recommendations of the SMA connector manufacturer. DC blocking capacitor at ANT pins (C2, C3) has to be placed in series to the 50 RF line. The ANT_DET pin has to be connected to the 50 transmission line by means of a sense line. Choke inductor in series at the ANT_DET pin (L1) has to be placed so that one pad is on the 50 transmission line and the other pad represents the start of the sense line to the ANT_DET pin. The additional components (R1, C1 and D1) on the ANT_DET line have to be placed as ESD protection. UBX-16029218 - R03 Design-in Page 52 of 94 SARA-R4 series - System Integration Manual 2.5 SIM interface 2.5.1 Guidelines for SIM circuit design Guidelines for SIM cards, SIM connectors and SIM chips selection The ISO/IEC 7816, the ETSI TS 102 221 and the ETSI TS 102 671 specifications define the physical, electrical and functional characteristics of Universal Integrated Circuit Cards (UICC), which contains the Subscriber Identification Module (SIM) integrated circuit that securely stores all the information needed to identify and authenticate subscribers over the LTE network. Removable UICC / SIM card contacts mapping is defined by ISO/IEC 7816 and ETSI TS 102 221 as follows: Contact C1 = VCC (Supply) It must be connected to VSIM Contact C2 = RST (Reset) It must be connected to SIM_RST Contact C3 = CLK (Clock) It must be connected to SIM_CLK Contact C4 = AUX1 (Auxiliary contact) It must be left not connected Contact C5 = GND (Ground) It must be connected to GND Contact C6 = VPP (Programming supply) It can be left not connected Contact C7 = I/O (Data input/output) It must be connected to SIM_IO Contact C8 = AUX2 (Auxiliary contact) It must be left not connected A removable SIM card can have 6 contacts (C1, C2, C3, C5, C6, C7) or 8 contacts, also including the auxiliary contacts C4 and C8. Only 6 contacts are required and must be connected to the module SIM interface. Removable SIM cards are suitable for applications requiring a change of SIM card during the product lifetime. A SIM card holder can have 6 or 8 positions if a mechanical card presence detector is not provided, or it can have 6+2 or 8+2 positions if two additional pins relative to the normally-open mechanical switch integrated in the SIM connector for the mechanical card presence detection are provided. Select a SIM connector providing 6+2 or 8+2 positions if the optional SIM detection feature is required by the custom application, otherwise a connector without integrated mechanical presence switch can be selected. Solderable UICC / SIM chip contact mapping (M2M UICC Form Factor) is defined by ETSI TS 102 671 as: Case Pin 8 = UICC Contact C1 = VCC (Supply) It must be connected to VSIM Case Pin 7 = UICC Contact C2 = RST (Reset) It must be connected to SIM_RST Case Pin 6 = UICC Contact C3 = CLK (Clock) It must be connected to SIM_CLK Case Pin 5 = UICC Contact C4 = AUX1 (Aux.contact) It must be left not connected Case Pin 1 = UICC Contact C5 = GND (Ground) It must be connected to GND Case Pin 2 = UICC Contact C6 = VPP (Progr. supply) It can be left not connected Case Pin 3 = UICC Contact C7 = I/O (Data I/O) It must be connected to SIM_IO Case Pin 4 = UICC Contact C8 = AUX2 (Aux. contact) It must be left not connected A solderable SIM chip has 8 contacts and can also include the auxiliary contacts C4 and C8 for other uses, but only 6 contacts are required and must be connected to the module SIM card interface as described above. Solderable SIM chips are suitable for M2M applications where it is not required to change the SIM once installed. UBX-16029218 - R03 Design-in Page 53 of 94 SARA-R4 series - System Integration Manual Guidelines for single SIM card connection without detection A removable SIM card placed in a SIM card holder has to be connected to the SIM card interface of SARA-R4 series modules as described in Figure 24, where the optional SIM detection feature is not implemented. Follow these guidelines to connect the module to a SIM connector without SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) to the VSIM pin of the module. Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module. Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module. Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module. Connect the UICC / SIM contact C5 (GND) to ground. Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) on SIM supply line, close to the relative pad of the SIM connector, to prevent digital noise. Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) on each SIM line, very close to each related pad of the SIM connector, to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holder. Provide a very low capacitance (i.e. less than 10 pF) ESD protection (e.g. Tyco PESD0402-140) on each externally accessible SIM line, close to each relative pad of the SIM connector. ESD sensitivity rating of the SIM interface pins is 1 kV (HBM). So that, according to EMC/ESD requirements of the custom application, higher protection level can be required if the lines are externally accessible on the application device. Limit capacitance and series resistance on each SIM signal to match the SIM requirements (27.7 ns is the maximum allowed rise time on clock line, 1.0 µs is the maximum allowed rise time on data and reset lines). SIM CARD HOLDER SARA-R4 series VPP (C6) VSIM 41 VCC (C1) SIM_IO 39 C C C C 5 6 7 8 IO (C7) SIM_CLK 38 CLK (C3) SIM_RST 40 RST (C2) C1 C2 C3 C4 GND (C5) C5 D1 D2 D3 D4 C C C C 1 2 3 4 SIM Card Bottom View (contacts side) J1 Figure 24: Application circuits for the connection to a single removable SIM card, with SIM detection not implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 47 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H470JA01 - Murata C5 D1, D2, D3, D4 100 nF Capacitor Ceramic X7R 0402 10% 16 V Very Low Capacitance ESD Protection GRM155R71C104KA01 - Murata PESD0402-140 - Tyco Electronics J1 SIM Card Holder, 6 p, without card presence switch Various manufacturers, as C707 10M006 136 2 - Amphenol Table 20: Example of components for the connection to a single removable SIM card, with SIM detection not implemented UBX-16029218 - R03 Design-in Page 54 of 94 SARA-R4 series - System Integration Manual Guidelines for single SIM chip connection A solderable SIM chip (M2M UICC Form Factor) has to be connected the SIM card interface of SARA-R4 series modules as described in Figure 25. Follow these guidelines to connect the module to a solderable SIM chip without SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) to the VSIM pin of the module. Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module. Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module. Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module. Connect the UICC / SIM contact C5 (GND) to ground. Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line close to the relative pad of the SIM chip, to prevent digital noise. Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) on each SIM line, to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM lines. Limit capacitance and series resistance on each SIM signal to match the SIM requirements (27.7 ns is the maximum allowed rise time on clock line, 1.0 µs is the maximum allowed rise time on data and reset lines). SARA-R4 series SIM CHIP VSIM 41 SIM_IO 39 SIM_CLK 38 SIM_RST 40 C1 C2 C3 C4 VPP (C6) VCC (C1) IO (C7) CLK (C3) RST (C2) GND (C5) C5 8 C1 C5 1 7 C2 C6 2 6 C3 C7 3 5 C4 C8 4 SIM Chip Bottom View (contacts side) U1 Figure 25: Application circuits for the connection to a single solderable SIM chip, with SIM detection not implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 47 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H470JA01 - Murata C5 U1 100 nF Capacitor Ceramic X7R 0402 10% 16 V SIM chip (M2M UICC Form Factor) GRM155R71C104KA01 - Murata Various Manufacturers Table 21: Example of components for the connection to a single solderable SIM chip, with SIM detection not implemented UBX-16029218 - R03 Design-in Page 55 of 94 SARA-R4 series - System Integration Manual Guidelines for single SIM card connection with detection An application circuit for the connection to a single removable SIM card placed in a SIM card holder is described in Figure 26, where the optional SIM card detection feature is implemented. Follow these guidelines connecting the module to a SIM connector implementing SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) to the VSIM pin of the module. Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module. Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module. Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module. Connect the UICC / SIM contact C5 (GND) to ground. Connect one pin of the normally-open mechanical switch integrated in the SIM connector (as the SW2 pin in Figure 26) to the GPIO5 input pin, providing a weak pull-down resistor (e.g. 470 k, as R2 in Figure 26). Connect the other pin of the normally-open mechanical switch integrated in the SIM connector (SW1 pin in Figure 26) to V_INT 1.8 V supply output by means of a strong pull-up resistor (e.g. 1 k, as R1 in Figure 26) Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM), close to the related pad of the SIM connector, to prevent digital noise. Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), very close to each related pad of the SIM connector, to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holder. Provide a low capacitance (i.e. less than 10 pF) ESD protection (e.g. Tyco Electronics PESD0402-140) on each externally accessible SIM line, close to each related pad of the SIM connector: ESD sensitivity rating of SIM interface pins is 1 kV (HBM according to JESD22-A114), so that, according to the EMC/ESD requirements of the custom application, higher protection level can be required if the lines are externally accessible. Limit capacitance and series resistance on each SIM signal to match the requirements for the SIM interface (27.7 ns = max allowed rise time on SIM_CLK, 1.0 µs = max allowed rise time on SIM_IO and SIM_RST). SIM CARD HOLDER SARA-R4 series V_INT TP R1 GPIO5 42 R2 VSIM 41 SW1 SW2 VPP (C6) VCC (C1) SIM_IO 39 IO (C7) SIM_CLK 38 CLK (C3) SIM_RST 40 RST (C2) C1 C2 C3 C4 C5 GND (C5) D1 D2 D3 D4 D5 D6 C C C C 5 6 7 8 C C C C 1 2 3 4 SIM Card Bottom View (contacts side) J1 Figure 26: Application circuit for the connection to a single removable SIM card, with SIM detection implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 C5 47 pF Capacitor Ceramic C0G 0402 5% 50 V 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM1555C1H470JA01 - Murata GRM155R71C104KA01 - Murata D1 – D6 R1 Very Low Capacitance ESD Protection PESD0402-140 - Tyco Electronics RC0402JR-071KL - Yageo Phycomp R2 470 k Resistor 0402 5% 0.1 W SIM Card Holder 6 + 2 positions, with card presence switch J1 1 k Resistor 0402 5% 0.1 W RC0402JR-07470KL- Yageo Phycomp Various Manufacturers, CCM03-3013LFT R102 - C&K Components Table 22: Example of components for the connection to a single removable SIM card, with SIM detection implemented UBX-16029218 - R03 Design-in Page 56 of 94 SARA-R4 series - System Integration Manual 2.5.2 Guidelines for SIM layout design The layout of the SIM card interface lines (VSIM, SIM_CLK, SIM_IO, SIM_RST may be critical if the SIM card is placed far away from the SARA-R4 series modules or in close proximity to the RF antenna: these two cases should be avoided or at least mitigated as described below. In the first case, the long connection can cause the radiation of some harmonics of the digital data frequency as any other digital interface. It is recommended to keep the traces short and avoid coupling with RF line or sensitive analog inputs. In the second case, the same harmonics can be picked up and create self-interference that can reduce the sensitivity of LTE receiver channels whose carrier frequency is coincidental with harmonic frequencies. It is strongly recommended to place the RF bypass capacitors suggested in Figure 24 near the SIM connector. In addition, since the SIM card is typically accessed by the end user, it can be subjected to ESD discharges. Add adequate ESD protection as suggested to protect module SIM pins near the SIM connector. Limit capacitance and series resistance on each SIM signal to match the SIM specifications. The connections should always be kept as short as possible. Avoid coupling with any sensitive analog circuit, since the SIM signals can cause the radiation of some harmonics of the digital data frequency. UBX-16029218 - R03 Design-in Page 57 of 94 SARA-R4 series - System Integration Manual 2.6 Data communication interfaces 2.6.1 UART interface 2.6.1.1 Guidelines for UART circuit design Providing the full RS-232 functionality (using the complete V.24 link) If RS-232 compatible signal levels are needed, two different external voltage translators can be used to provide full RS-232 (9 lines) functionality: e.g. using the Texas Instruments SN74AVC8T245PW for the translation from 1.8 V to 3.3 V, and the Maxim MAX3237E for the translation from 3.3 V to RS-232 compatible signal level. If a 1.8 V Application Processor (DTE) is used and complete RS-232 functionality is required, then the complete 1.8 V UART interface of the module (DCE) should be connected to a 1.8 V DTE, as described in Figure 27. Application Processor (1.8V DTE) SARA-R4 (1.8V DCE) TxD 0Ω TP 0Ω TP 0Ω TP 0Ω TP 12 TXD 13 RXD 10 RTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD RxD RTS CTS GND GND Figure 27: UART interface application circuit with complete V.24 link in DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor (DTE) is used, then it is recommended to connect the 1.8 V UART interface of the module (DCE) by means of appropriate unidirectional voltage translators using the module V_INT output as 1.8 V supply for the voltage translators on the module side, as described in Figure 28. Application Processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC C1 VCCA DIR1 DIR3 TxD A1 B1 A2 B2 RTS A3 B3 CTS A4 B4 DIR2 DIR4 C3 VCCA C2 0Ω TP 0Ω TP 0Ω TP 0Ω TP V_INT 12 TXD 13 RXD 10 RTS 11 CTS OE GND U1 Unidirectional Voltage Translator 3V0 TP VCCB RxD SARA-R4 (1.8V DCE) 1V8 VCCB DIR1 1V8 C4 DTR A1 B1 DTR DSR A2 B2 DSR RI A3 B3 RI DCD A4 B4 DCD GND DIR2 DIR3 DIR4 OE GND GND U2 Figure 28: UART interface application circuit with complete V.24 link in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2, C3, C4 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1, U2 Unidirectional Voltage Translator SN74AVC4T7743 - Texas Instruments Table 23: Component for UART application circuit with complete V.24 link in DTE/DCE serial communication (3.0 V DTE) Voltage translator providing partial power down feature so that the DTE 3.0 V supply can be also ramped up before V_INT 1.8 V supply UBX-16029218 - R03 Design-in Page 58 of 94 SARA-R4 series - System Integration Manual Providing the TXD, RXD, RTS, CTS and DTR lines only (not using the complete V.24 link) If the functionality of the DSR, DCD and RI lines is not required, or the lines are not available: Leave DSR, DCD and RI lines of the module floating, with a test-point on DCD If RS-232 compatible signal levels are needed, two different external voltage translators (e.g. Maxim MAX3237E and Texas Instruments SN74AVC4T774) can be used. The Texas Instruments chips provide the translation from 1.8 V to 3.3 V, while the Maxim chip provides the translation from 3.3 V to RS-232 compatible signal level. Figure 29 describes the circuit that should be implemented as if a 1.8 V Application Processor (DTE) is used, given that the DTE will behave properly regardless DSR input setting. Application Processor (1.8V DTE) SARA-R4 (1.8V DCE) TxD RxD RTS CTS 0Ω TP 0Ω TP 0Ω TP 0Ω TP 12 TXD 13 RXD 10 RTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD GND GND Figure 29: UART interface application circuit with partial V.24 link (6-wire) in the DTE/DCE serial communication (1.8 V DTE) If a 3.0 V Application Processor (DTE) is used, then it is recommended to connect the 1.8 V UART interface of the module (DCE) by means of appropriate unidirectional voltage translators using the module V_INT output as 1.8 V supply for the voltage translators on the module side, as described in Figure 30, given that the DTE will behave properly regardless DSR input setting. Application Processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC VCCA DIR1 DIR3 C1 V_INT 12 TXD 13 RXD 10 RTS 11 CTS B1 B2 DTR DSR OE GND RI DCD VCCB TxD A1 B1 RxD A2 B2 RTS A3 B3 CTS A4 B4 DIR2 DIR4 SARA-R4 (1.8V DCE) 1V8 C2 0Ω TP 0Ω 0Ω TP TP 0Ω TP OE GND U1 Unidirectional Voltage Translator 3V0 C3 DTR DSR VCCA VCCB DIR1 DIR2 A1 A2 RI DCD 1V8 C4 U2 GND GND Figure 30: UART interface application circuit with partial V.24 link (6-wire) in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2, C3, C4 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1 U2 Unidirectional Voltage Translator Unidirectional Voltage Translator SN74AVC4T7744 - Texas Instruments SN74AVC2T2454 - Texas Instruments Table 24: Component for UART application circuit with partial V.24 link (6-wire) in DTE/DCE serial communication (3.0 V DTE) Voltage translator providing partial power down feature so that the DTE 3.0 V supply can be also ramped up before V_INT 1.8 V supply UBX-16029218 - R03 Design-in Page 59 of 94 SARA-R4 series - System Integration Manual Providing the TXD, RXD, RTS and CTS lines only (not using the complete V.24 link) If the functionality of the DSR, DCD, RI and DTR lines is not required in, or the lines are not available: Connect the module DTR input to GND using a 0 series resistor, since it may be useful to set DTR active if not specifically handled (see SARA-R4 series AT Commands Manual [1], &D, S0, +CSGT, +CNMI AT commands) Leave DSR, DCD and RI lines of the module floating, with a test-point on DCD If RS-232 compatible signal levels are needed, the Maxim MAX13234E voltage level translator can be used. This chip translates voltage levels from 1.8 V (module side) to the RS-232 standard. If a 1.8 V Application Processor is used, the circuit should be implemented as described in Figure 31. Application Processor (1.8V DTE) SARA-R4 (1.8V DCE) TxD RxD RTS CTS 0Ω TP 0Ω TP 0Ω TP 0Ω TP 12 TXD 13 RXD 10 RTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD GND GND Figure 31: UART interface application circuit with partial V.24 link (5-wire) in the DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor (DTE) is used, then it is recommended to connect the 1.8 V UART interface of the module (DCE) by means of appropriate unidirectional voltage translators using the module V_INT output as 1.8 V supply for the voltage translators on the module side, as described in Figure 32. Application Processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC C1 VCCA DIR1 DIR3 VCCB SARA-R4 series (1.8V DCE) 1V8 TP C2 0Ω TP 0Ω TP V_INT TxD A1 B1 RxD A2 B2 RTS A3 B3 10 RTS CTS A4 B4 11 CTS DIR2 DIR4 U1 DTR 12 TXD 13 RXD OE GND 0Ω TP DTR DSR DSR RI RI DCD DCD GND TP GND Figure 32: UART interface application circuit with partial V.24 link (5-wire) in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1 Unidirectional Voltage Translator SN74AVC4T7745 - Texas Instruments Table 25: Component for UART application circuit with partial V.24 link (5-wire) in DTE/DCE serial communication (3.0 V DTE) Voltage translator providing partial power down feature so that the DTE 3.0 V supply can be also ramped up before V_INT 1.8 V supply UBX-16029218 - R03 Design-in Page 60 of 94 SARA-R4 series - System Integration Manual Providing the TXD and RXD lines only (not using the complete V24 link) If the functionality of the CTS, RTS, DSR, DCD, RI and DTR lines is not required in the application, or the lines are not available, then: Connect the module RTS input line to GND or to the CTS output line of the module: since the module requires RTS active (low electrical level) if HW flow-control is enabled (AT&K3, which is the default setting) Connect the module DTR input line to GND using a 0 series resistor, because it is useful to set DTR active if not specifically handled (see SARA-R4 series AT Commands Manual [2], &D, S0, +CSGT, +CNMI AT commands) Leave DSR, DCD and RI lines of the module floating, with a test-point on DCD If RS-232 compatible signal levels are needed, the Maxim MAX13234E voltage level translator can be used. This chip translates voltage levels from 1.8 V (module side) to the RS-232 standard. If a 1.8 V Application Processor (DTE) is used, the circuit that should be implemented as described in Figure 33 Application Processor (1.8V DTE) SARA-R4 (1.8V DCE) TxD 0Ω TP 0Ω TP 0Ω TP 12 TXD 13 RXD 10 RTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD RxD RTS TP CTS GND GND Figure 33: UART interface application circuit with partial V.24 link (3-wire) in the DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor (DTE) is used, then it is recommended to connect the 1.8 V UART interface of the module (DCE) by means of appropriate unidirectional voltage translators using the module V_INT output as 1.8 V supply for the voltage translators on the module side, as described in Figure 34. Application Processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC C1 VCCA TP VCCB C2 DIR1 TxD A1 B1 RxD A2 B2 SARA-R4 (1.8V DCE) 1V8 0Ω TP 0Ω TP 0Ω TP V_INT 12 TXD 13 RXD 10 RTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD DIR2 U1 RTS OE GND CTS GND TP GND Figure 34: UART interface application circuit with partial V.24 link (3-wire) in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1 Unidirectional Voltage Translator SN74AVC2T2456 - Texas Instruments Table 26: Component for UART application circuit with partial V.24 link (3-wire) in DTE/DCE serial communication (3.0 V DTE) Voltage translator providing partial power down feature so that the DTE 3.0 V supply can be also ramped up before V_INT 1.8 V supply UBX-16029218 - R03 Design-in Page 61 of 94 SARA-R4 series - System Integration Manual Additional considerations If a 3.0 V Application Processor (DTE) is used, the voltage scaling from any 3.0 V output of the DTE to the corresponding 1.8 V input of the module (DCE) can be implemented as an alternative low-cost solution, by means of an appropriate voltage divider. Consider the value of the pull-up integrated at the input of the module (DCE) for the correct selection of the voltage divider resistance values. Make sure that any DTE signal connected to the module is tri-stated or set low when the module is in power-down mode and during the module poweron sequence (at least until the activation of the V_INT supply output of the module), to avoid latch-up of circuits and allow a proper boot of the module (see the remark below). Moreover, the voltage scaling from any 1.8 V output of the cellular module (DCE) to the corresponding 3.0 V input of the Application Processor (DTE) can be implemented by means of an appropriate low-cost non-inverting buffer with open drain output. The non-inverting buffer should be supplied by the V_INT supply output of the cellular module. Consider the value of the pull-up integrated at each input of the DTE (if any) and the baud rate required by the application for the appropriate selection of the resistance value for the external pull-up biased by the application processor supply rail. Do not apply voltage to any UART interface pin before the switch-on of the UART supply source (V_INT), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the cellular module cannot be tri-stated or set low, insert a multi channel digital switch (e.g. TI SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance before V_INT switch-on. ESD sensitivity rating of UART interface pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the lines are externally accessible and it can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible points. 2.6.1.2 Guidelines for UART layout design The UART serial interface requires the same consideration regarding electro-magnetic interference as any other digital interface. Keep the traces short and avoid coupling with RF line or sensitive analog inputs, since the signals can cause the radiation of some harmonics of the digital data frequency. UBX-16029218 - R03 Design-in Page 62 of 94 SARA-R4 series - System Integration Manual 2.6.2 USB interface 2.6.2.1 Guidelines for USB circuit design The USB_D+ and USB_D- lines carry the USB serial data and signaling. The lines are used in single ended mode for full speed signaling handshake, as well as in differential mode for high speed signaling and data transfer. USB pull-up or pull-down resistors and external series resistors on USB_D+ and USB_D- lines as required by the USB 2.0 specification [4] are part of the module USB pins driver and do not need to be externally provided. The USB interface of the module is enabled only if a valid voltage is detected by the VUSB_DET input (see the SARA-R4 series Data Sheet [1]). Neither the USB interface, nor the whole module is supplied by the VUSB_DET input: the VUSB_DET senses the USB supply voltage and absorbs few microamperes. Routing the USB pins to a connector, they will be externally accessible on the application device. According to EMC/ESD requirements of the application, an additional ESD protection device with very low capacitance should be provided close to accessible point on the line connected to this pin, as described in Figure 35 and Table 27. The USB interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible and it can be achieved by mounting a very low capacitance (i.e. less or equal to 1 pF) ESD protection (e.g. Tyco Electronics PESD0402-140 ESD protection device) on the lines connected to these pins, close to accessible points. The USB pins of the modules can be directly connected to the USB host application processor without additional ESD protections if they are not externally accessible or according to EMC/ESD requirements. USB DEVICE CONNECTOR SARA-R4 series VBUS 17 VUSB_DET USB HOST PROCESSOR SARA-R4 series VBUS 17 VUSB_DET D+ 29 USB_D+ D+ 29 USB_D+ D- 28 USB_D- D- 28 USB_D- GND D1 D2 D3 C1 GND GND C1 GND Figure 35: USB Interface application circuits Reference Description Part Number - Manufacturer C1 D1, D2, D3 100 nF Capacitor Ceramic X7R 0402 10% 16 V Very Low Capacitance ESD Protection GRM155R61A104KA01 - Murata PESD0402-140 - Tyco Electronics Table 27: Component for USB application circuits If the USB interface pins are not used, they can be left unconnected on the application board, but it is recommended providing accessible test points directly connected to VUSB_DET, USB_D+, USB_D- pins. UBX-16029218 - R03 Design-in Page 63 of 94 SARA-R4 series - System Integration Manual 2.6.2.2 Guidelines for USB layout design The USB_D+ / USB_D- lines require accurate layout design to achieve reliable signaling at the high speed data rate (up to 480 Mb/s) supported by the USB serial interface. The characteristic impedance of the USB_D+ / USB_D- lines is specified by the Universal Serial Bus Revision 2.0 specification [4]. The most important parameter is the differential characteristic impedance applicable for the odd-mode electromagnetic field, which should be as close as possible to 90 differential. Signal integrity may be degraded if PCB layout is not optimal, especially when the USB signaling lines are very long. Use the following general routing guidelines to minimize signal quality problems: Route USB_D+ / USB_D- lines as a differential pair Route USB_D+ / USB_D- lines as short as possible Ensure the differential characteristic impedance (Z 0) is as close as possible to 90 Ensure the common mode characteristic impedance (ZCM) is as close as possible to 30 Consider design rules for USB_D+ / USB_D- similar to RF transmission lines, being them coupled differential micro-strip or buried stripline: avoid any stubs, abrupt change of layout, and route on clear PCB area Figure 36 and Figure 37 provide two examples of coplanar waveguide designs with differential characteristic impedance close to 90 and common mode characteristic impedance close to 30 . The first transmission line can be implemented in case of 4-layer PCB stack-up herein described, the second transmission line can be implemented in case of 2-layer PCB stack-up herein described. 400 µm 350 µm 400 µm 350 µm 400 µm L1 Copper 35 µm FR-4 dielectric 270 µm L2 Copper 35 µm FR-4 dielectric 760 µm L3 Copper 35 µm FR-4 dielectric 270 µm L4 Copper 35 µm Figure 36: Example of USB line design, with Z0 close to 90 and ZCM close to 30 , for the described 4-layer board layup 410 µm 740 µm 410 µm 740 µm 410 µm L1 Copper 35 µm FR-4 dielectric 1510 µm L2 Copper 35 µm Figure 37: Example of USB line design, with Z0 close to 90 and ZCM close to 30 , for the described 2-layer board layup UBX-16029218 - R03 Design-in Page 64 of 94 SARA-R4 series - System Integration Manual 2.6.3 DDC (I2C) interface 2.6.3.1 Guidelines for DDC (I C) circuit design DDC (I C) interface is not supported by “00” and “01” product versions. 2.7 General Purpose Input/Output 2.7.1.1 Guidelines for GPIO circuit design A typical usage of SARA-R4 series modules’ GPIOs can be the following: Network indication provided over GPIO1 pin (see Figure 38 / Table 28 below) SIM card detection provided over GPIO5 pin (see Figure 26 / Table 22 in section 2.5) 3V8 SARA-R4 series R3 GPIO1 16 Network Indicator DL1 R1 T1 R2 Figure 38: Application circuit for network indication provided over GPIO1 Reference Description Part Number - Manufacturer R1 10 k Resistor 0402 5% 0.1 W Various manufacturers R2 47 k Resistor 0402 5% 0.1 W Various manufacturers R3 820 Resistor 0402 5% 0.1 W LED Red SMT 0603 Various manufacturers DL1 T1 NPN BJT Transistor BC847 - Infineon LTST-C190KRKT - Lite-on Technology Corporation Table 28: Components for network indication application circuit Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 k resistor on the board in series to the GPIO of SARA-R4 series modules. Do not apply voltage to any GPIO of the module before the switch-on of the GPIOs supply (V_INT), to avoid latch-up of circuits and allow a proper module boot. If the external signals connected to the module cannot be tri-stated or set low, insert a multi channel digital switch (e.g. TI SN74CB3Q16244, TS5A3159, TS5A63157) between the two-circuit connections and set to high impedance before V_INT switch-on. ESD sensitivity rating of the GPIO pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the lines are externally accessible and it can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible points. If the GPIO pins are not used, they can be left unconnected on the application board. 2.7.1.2 Guidelines for general purpose input/output layout design The general purpose inputs / outputs pins are generally not critical for layout. UBX-16029218 - R03 Design-in Page 65 of 94 SARA-R4 series - System Integration Manual 2.8 Reserved pins (RSVD) SARA-R4 series modules have pins reserved for future use, marked as RSVD. All the RSVD pins are to be left unconnected. 2.9 Module placement An optimized placement allows a minimum RF line’s length and closer path from DC source for VCC. Make sure that the module, analog parts and RF circuits are clearly separated from any possible source of radiated energy. In particular, digital circuits can radiate digital frequency harmonics, which can produce ElectroMagnetic Interference that affects the module, analog parts and RF circuits’ performance. Implement proper countermeasures to avoid any possible Electro-Magnetic Compatibility issue. Make sure that the module, RF and analog parts / circuits, and high speed digital circuits are clearly separated from any sensitive part / circuit which may be affected by Electro-Magnetic Interference, or employ countermeasures to avoid any possible Electro-Magnetic Compatibility issue. Provide enough clearance between the module and any external part: clearance of at least 0.4 mm per side is recommended to let suitable mounting of the parts. The heat dissipation during continuous transmission at maximum power can significantly raise the temperature of the application base-board below the SARA-R4 series modules: avoid placing temperature sensitive devices close to the module. UBX-16029218 - R03 Design-in Page 66 of 94 SARA-R4 series - System Integration Manual 2.10 Module footprint and paste mask Figure 39 and Table 29 describe the suggested footprint (i.e. copper mask) and paste mask layout for SARA modules: the proposed land pattern layout reflects the modules’ pins layout, while the proposed stencil apertures layout is slightly different (see the F’’, H’’, I’’, J’’, O’’ parameters compared to the F’, H’, I’, J’, O’ ones). The Non Solder Mask Defined (NSMD) pad type is recommended over the Solder Mask Defined (SMD) pad type, implementing the solder mask opening 50 µm larger per side than the corresponding copper pad. The recommended solder paste thickness is 150 µm, according to application production process requirements. Pin 1 H’ ANT pin J’ Pin 1 I’ H’’ J’’ ANT pin I’’ M1 M1 M1 M1 M2 M2 O’ O’’ O’ O’’ Stencil: 150 µm H’ A H’’ A J’ J’’ F’ F’’ F’ F’’ Figure 39: SARA-R4 series modules suggested footprint and paste mask (application board top view) Parameter Value Parameter Value Parameter Value 26.0 mm 1.10 mm 2.75 mm 16.0 mm H’ 0.80 mm 2.75 mm 3.00 mm H’’ 0.75 mm M1 1.80 mm 2.00 mm I’ 1.50 mm M2 3.60 mm 2.50 mm I’’ 1.55 mm 2.10 mm F’ 1.05 mm J’ 0.30 mm O’ 1.10 mm F’’ 1.00 mm J’’ 0.35 mm O’’ 1.05 mm Table 29: SARA-R4 series modules suggested footprint and paste mask dimensions These are recommendations only and not specifications. The exact copper, solder and paste mask geometries, distances, stencil thicknesses and solder paste volumes must be adapted to the specific production processes (e.g. soldering etc.) of the customer. UBX-16029218 - R03 Design-in Page 67 of 94 SARA-R4 series - System Integration Manual 2.11 Thermal guidelines The module operating temperature range is specified in SARA-R4 series Data Sheet [1]. The most critical condition concerning module thermal performance is the uplink transmission at maximum power (data upload in connected-mode), when the baseband processor runs at full speed, radio circuits are all active and the RF power amplifier is driven to higher output RF power. This scenario is not often encountered in real networks (for example, see the Terminal Tx Power distribution for WCDMA, taken from operation on a live network, described in the GSMA TS.09 Battery Life Measurement and Current Consumption Technique [10]); however the application should be correctly designed to cope with it. During transmission at maximum RF power the SARA-R4 series modules generate thermal power that may exceed 0.5 W: this is an indicative value since the exact generated power strictly depends on operating condition such as the actual antenna return loss, the transmitting frequency band, etc. The generated thermal power must be adequately dissipated through the thermal and mechanical design of the application. The spreading of the Module-to-Ambient thermal resistance (Rth,M-A) depends on the module operating condition. The overall temperature distribution is influenced by the configuration of the active components during the specific mode of operation and their different thermal resistance toward the case interface. The Module-to-Ambient thermal resistance value and the relative increase of module temperature will differ according to the specific mechanical deployments of the module, e.g. application PCB with different dimensions and characteristics, mechanical shells enclosure, or forced air flow. The increase of the thermal dissipation, i.e. the reduction of the Module-to-Ambient thermal resistance, will decrease the temperature of the modules’ internal circuitry for a given operating ambient temperature. This improves the device long-term reliability in particular for applications operating at high ambient temperature. Recommended hardware techniques to be used to improve heat dissipation in the application: Connect each GND pin with solid ground layer of the application board and connect each ground area of the multilayer application board with complete thermal via stacked down to main ground layer. Provide a ground plane as wide as possible on the application board. Optimize antenna return loss, to optimize overall electrical performance of the module including a decrease of module thermal power. Optimize the thermal design of any high-power components included in the application, such as linear regulators and amplifiers, to optimize overall temperature distribution in the application device. Select the material, the thickness and the surface of the box (i.e. the mechanical enclosure) of the application device that integrates the module so that it provides good thermal dissipation. Beside the reduction of the Module-to-Ambient thermal resistance implemented by proper application hardware design, the increase of module temperature can be moderated by proper application software implementation: Enable power saving configuration using the AT+CPSMS command Enable module connected-mode for a given time period and then disable it for a time period enough long to properly mitigate temperature increase. UBX-16029218 - R03 Design-in Page 68 of 94 SARA-R4 series - System Integration Manual 2.12 Schematic for SARA-R4 series module integration 2.12.1 Schematic for SARA-R4 series modules Figure 40 is an example of a schematic diagram where a SARA-R4 series module “00” or “01” product version is integrated into an application board, using all the available interfaces and functions of the module. SARA-R4 series 15pF 3V8 10uF 100nF 10nF 68pF 51 VCC 52 VCC 53 VCC 15pF ANT Connector 33pF 56 39nH GND ANT_DET 82nH 10k 62 27pF Application Processor ESD V_INT TP Open drain output TP Open drain output 15 18 PWR_ON D- 0Ω TP 0Ω TP 0Ω TP 1k GPIO5 42 SW2 VSIM 41 CCVCC (C1) SIM_IO 39 CCIO (C7) SIM_CLK 38 CCCLK (C3) SIM_RST 40 CCRST (C2) SW1 CCVPP (C6) RESET_N 470k 47pF 47pF 47pF 47pF 100nF 17 VUSB_DET 28 USB_D- 29 USB_D+ SDA 26 GND SCL 27 12 TXD GPIO6 19 13 RXD GPIO4 25 RTS 10 RTS GPIO3 24 D+ SIM Card Holder TP V_INT USB 2.0 host VBUS GND External antenna GND (C5) ESD ESD ESD ESD ESD ESD 1.8 V DTE TXD RXD 0Ω TP 0Ω TP CTS 11 CTS GPIO2 23 DTR DTR GPIO1 16 DSR DSR RI RI DCD DCD GND 3V8 Network Indicator GND RSVD GND Figure 40: Example of schematic diagram to integrate a SARA-R4 module using all available interfaces UBX-16029218 - R03 Design-in Page 69 of 94 SARA-R4 series - System Integration Manual 2.13 Design-in checklist This section provides a design-in checklist. 2.13.1 Schematic checklist The following are the most important points for a simple schematic check: DC supply must provide a nominal voltage at VCC pin within the operating range limits. VCC voltage supply should be clean, with very low ripple/noise: provide the suggested bypass capacitors, in particular if the application device integrates an internal antenna. Do not apply loads which might exceed the limit for maximum available current from V_INT supply. Capacitance and series resistance must be limited on each SIM signal to match the SIM specifications. Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 k resistor on the board in series to the GPIO when those are used to drive LEDs. Provide proper precautions for EMC / ESD immunity as required on the application board. All unused pins can be left unconnected. DC supply must be capable of supporting the highest averaged current consumption values in connected-mode, as specified in the SARA-R4 series Data Sheet [1]. Check that voltage level of any connected pin does not exceed the relative operating range. Provide accessible test points directly connected to the following pins of the SARA-R4 series modules: V_INT, PWR_ON and RESET_N for diagnostic purpose. Insert the suggested pF capacitors on each SIM signal and low capacitance ESD protections if accessible. Check UART signals direction, as the modules’ signal names follow the ITU-T V.24 Recommendation [5]. Capacitance and series resistance must be limited on each high speed line of the USB interface. If the USB is not used, provide accessible test points directly connected to the USB interface (VUSB_DET, USB_D+ and USB_D- pins). Do not apply voltage to any generic digital interface pin of SARA-R4 series modules before the switchon of the generic digital interface supply source (V_INT). UBX-16029218 - R03 Design-in Page 70 of 94 SARA-R4 series - System Integration Manual 2.13.2 Layout checklist The following are the most important points for a simple layout check: Check 50 nominal characteristic impedance of the RF transmission line connected to the ANT port (antenna RF interface). Ensure no coupling occurs between the RF interface and noisy or sensitive signals (SIM signals, high-speed digital lines such as USB, and other data lines). Optimize placement for minimum length of RF line. Ensure an optimal grounding connecting each GND pin with application board solid ground layer. Keep routing short and minimize parasitic capacitance on the SIM lines to preserve signal integrity. Check the footprint and paste mask designed for SARA-R4 series module as illustrated in section 2.10. VCC line should be wide and as short as possible. Route VCC supply line away from RF line / part and other sensitive analog lines / parts. The VCC bypass capacitors in the picoFarad range should be placed as close as possible to the VCC pins, in particular if the application device integrates an internal antenna. Use as many vias as possible to connect the ground planes on multilayer application board, providing a dense line of vias at the edges of each ground area, in particular along RF and high speed lines. USB_D+ / USB_D- traces should meet the characteristic impedance requirement (90 differential and 30 common mode) and should not be routed close to any RF line / part. 2.13.3 Antenna checklist Antenna termination should provide 50 characteristic impedance with V.S.W.R at least less than 3:1 (recommended 2:1) on operating bands in deployment geographical area. Follow the recommendations of the antenna producer for correct antenna installation and deployment (PCB layout and matching circuitry). Ensure compliance with any regulatory agency RF radiation requirement, as reported in section 4.2.2 for products marked with the FCC. Ensure high isolation between the cellular antenna and any other antennas or transmitters present on the end device. UBX-16029218 - R03 Design-in Page 71 of 94 SARA-R4 series - System Integration Manual 3 Handling and soldering No natural rubbers, no hygroscopic materials or materials containing asbestos are employed. 3.1 Packaging, shipping, storage and moisture preconditioning For information pertaining to SARA-R4 series reels / tapes, Moisture Sensitivity levels (MSD), shipment and storage information, as well as drying for preconditioning, see the SARA-R4 series Data Sheet [1] and the u-blox Package Information Guide [15]. 3.2 Handling The SARA-R4 series modules are Electro-Static Discharge (ESD) sensitive devices. Ensure ESD precautions are implemented during handling of the module. Electrostatic discharge (ESD) is the sudden and momentary electric current that flows between two objects at different electrical potentials caused by direct contact or induced by an electrostatic field. The term is usually used in the electronics and other industries to describe momentary unwanted currents that may cause damage to electronic equipment. The ESD sensitivity for each pin of SARA-R4 series modules (as Human Body Model according to JESD22-A114F) is specified in the SARA-R4 series Data Sheet [1]. ESD prevention is based on establishing an Electrostatic Protective Area (EPA). The EPA can be a small working station or a large manufacturing area. The main principle of an EPA is that there are no highly charging materials near ESD sensitive electronics, all conductive materials are grounded, workers are grounded, and charge build-up on ESD sensitive electronics is prevented. International standards are used to define typical EPA and can be obtained for example from International Electrotechnical Commission (IEC) or American National Standards Institute (ANSI). In addition to standard ESD safety practices, the following measures should be taken into account whenever handling the SARA-R4 series modules: Unless there is a galvanic coupling between the local GND (i.e. the work table) and the PCB GND, then the first point of contact when handling the PCB must always be between the local GND and PCB GND. Before mounting an antenna patch, connect ground of the device. When handling the module, do not come into contact with any charged capacitors and be careful when contacting materials that can develop charges (e.g. patch antenna, coax cable, soldering iron,…). To prevent electrostatic discharge through the RF pin, do not touch any exposed antenna area. If there is any risk that such exposed antenna area is touched in non ESD protected work area, implement proper ESD protection measures in the design. When soldering the module and patch antennas to the RF pin, make sure to use an ESD safe soldering iron. UBX-16029218 - R03 Handling and soldering Page 72 of 94 SARA-R4 series - System Integration Manual 3.3 Soldering 3.3.1 Soldering paste "No Clean" soldering paste is strongly recommended for SARA-R4 series modules, as it does not require cleaning after the soldering process has taken place. The paste listed in the example below meets these criteria. Soldering Paste: OM338 SAC405 / Nr.143714 (Cookson Electronics) Alloy specification: 95.5% Sn / 3.9% Ag / 0.6% Cu (95.5% Tin / 3.9% Silver / 0.6% Copper) 95.5% Sn / 4.0% Ag / 0.5% Cu (95.5% Tin / 4.0% Silver / 0.5% Copper) Melting Temperature: 217 °C Stencil Thickness: 150 µm for base boards The final choice of the soldering paste depends on the approved manufacturing procedures. The paste-mask geometry for applying soldering paste should meet the recommendations in section 2.10. The quality of the solder joints on the connectors (“half vias”) should meet the appropriate IPC specification. 3.3.2 Reflow soldering A convection type-soldering oven is strongly recommended for SARA-R4 series modules over the infrared type radiation oven. Convection heated ovens allow precise control of the temperature and all parts will be heated up evenly, regardless of material properties, thickness of components and surface color. Consider the ”IPC-7530 Guidelines for temperature profiling for mass soldering (reflow and wave) processes”, published 2001. Reflow profiles are to be selected according to the following recommendations. Failure to observe these recommendations can result in severe damage to the device! Preheat phase Initial heating of component leads and balls. Residual humidity will be dried out. Note that this preheat phase will not replace prior baking procedures. Temperature rise rate: max 3 °C/s If the temperature rise is too rapid in the preheat phase it may cause excessive slumping. Time: 60 – 120 s If the preheat is insufficient, rather large solder balls tend to be generated. Conversely, if performed excessively, fine balls and large balls will be generated in clusters. End Temperature: 150 - 200 °C If the temperature is too low, non-melting tends to be caused in areas containing large heat capacity. Heating/ reflow phase The temperature rises above the liquidus temperature of 217 °C. Avoid a sudden rise in temperature as the slump of the paste could become worse. Limit time above 217 °C liquidus temperature: 40 - 60 s Peak reflow temperature: 245 °C Cooling phase A controlled cooling avoids negative metallurgical effects (solder becomes more brittle) of the solder and possible mechanical tensions in the products. Controlled cooling helps to achieve bright solder fillets with a good shape and low contact angle. Temperature fall rate: max 4 °C/s UBX-16029218 - R03 Handling and soldering Page 73 of 94 SARA-R4 series - System Integration Manual To avoid falling off, modules should be placed on the topside of the motherboard during soldering. The soldering temperature profile chosen at the factory depends on additional external factors like choice of soldering paste, size, thickness and properties of the base board, etc. Exceeding the maximum soldering temperature and the maximum liquidus time limit in the recommended soldering profile may permanently damage the module. Preheat [°C] 250 Heating Peak Temp. 245°C Cooling [°C] 250 Liquidus Temperature 217 200 217 200 40 - 60 s End Temp. 150 - 200°C max 4°C/s 150 150 max 3°C/s 60 - 120 s Typical Leadfree Soldering Profile 100 50 100 50 Elapsed time [s] Figure 41: Recommended soldering profile The modules must not be soldered with a damp heat process. 3.3.3 Optical inspection After soldering the SARA-R4 series modules, inspect the modules optically to verify that the module is properly aligned and centered. 3.3.4 Cleaning Cleaning the modules is not recommended. Residues underneath the modules cannot be easily removed with a washing process. Cleaning with water will lead to capillary effects where water is absorbed in the gap between the baseboard and the module. The combination of residues of soldering flux and encapsulated water leads to short circuits or resistor-like interconnections between neighboring pads. Water will also damage the sticker and the inkjet printed text. Cleaning with alcohol or other organic solvents can result in soldering flux residues flooding into the two housings, areas that are not accessible for post-wash inspections. The solvent will also damage the sticker and the ink-jet printed text. Ultrasonic cleaning will permanently damage the module, in particular the quartz oscillators. For best results use a "no clean" soldering paste and eliminate the cleaning step after the soldering. UBX-16029218 - R03 Handling and soldering Page 74 of 94 SARA-R4 series - System Integration Manual 3.3.5 Repeated reflow soldering Only a single reflow soldering process is encouraged for boards with a module populated on it. 3.3.6 Wave soldering Boards with combined through-hole technology (THT) components and surface-mount technology (SMT) devices require wave soldering to solder the THT components. Only a single wave soldering process is encouraged for boards populated with the modules. 3.3.7 Hand soldering Hand soldering is not recommended. 3.3.8 Rework Rework is not recommended. Never attempt a rework on the module itself, e.g. replacing individual components. Such actions immediately terminate the warranty. 3.3.9 Conformal coating ® Certain applications employ a conformal coating of the PCB using HumiSeal or other related coating products. These materials affect the HF properties of the cellular modules and it is important to prevent them from flowing into the module. The RF shields do not provide 100% protection for the module from coating liquids with low viscosity, therefore care is required in applying the coating. Conformal Coating of the module will void the warranty. 3.3.10 Casting If casting is required, use viscose or another type of silicon pottant. The OEM is strongly advised to qualify such processes in combination with the cellular modules before implementing this in the production. Casting will void the warranty. 3.3.11 Grounding metal covers Attempts to improve grounding by soldering ground cables, wick or other forms of metal strips directly onto the EMI covers is done at the customer's own risk. The numerous ground pins should be sufficient to provide optimum immunity to interferences and noise. u-blox gives no warranty for damages to the cellular modules caused by soldering metal cables or any other forms of metal strips directly onto the EMI covers. 3.3.12 Use of ultrasonic processes The cellular modules contain components which are sensitive to Ultrasonic Waves. Use of any Ultrasonic Processes (cleaning, welding etc.) may cause damage to the module. u-blox gives no warranty against damages to the cellular modules caused by any Ultrasonic Processes. UBX-16029218 - R03 Handling and soldering Page 75 of 94 SARA-R4 series - System Integration Manual 4 Approvals For the complete list and specific details regarding the certification schemes approvals, see SARA-R4 series Data Sheet [1], or please contact the u-blox office or sales representative nearest you. 4.1 Product certification approval overview Product certification approval is the process of certifying that a product has passed all tests and criteria required by specifications, typically called “certification schemes” that can be divided into three distinct categories: Regulatory certification o Country specific approval required by local government in most regions and countries, such as: CE (Conformité Européenne) marking for European Union FCC (Federal Communications Commission) approval for United States Industry certification Telecom industry specific approval verifying the interoperability between devices and networks: GCF (Global Certification Forum), partnership between European device manufacturers and network operators to ensure and verify global interoperability between devices and networks PTCRB (PCS Type Certification Review Board), created by United States network operators to ensure and verify interoperability between devices and North America networks Operator certification Operator specific approval required by some mobile network operator, such as: AT&T network operator in United States Verizon Wireless network operator in United States Even if SARA-R4 series modules are approved under all major certification schemes, the application device that integrates SARA-R4 series modules must be approved under all the certification schemes required by the specific application device to be deployed in the market. The required certification scheme approvals and relative testing specifications differ depending on the country or the region where the device that integrates SARA-R4 series modules must be deployed, on the relative vertical market of the device, on type, features and functionalities of the whole application device, and on the network operators where the device must operate. Check the appropriate applicability of the SARA-R4 series module’s approvals while starting the certification process of the device integrating the module: the re-use of the u-blox cellular module’s approval can significantly reduce the cost and time to market of the application device certification. The certification of the application device that integrates a SARA-R4 series module and the compliance of the application device with all the applicable certification schemes, directives and standards are the sole responsibility of the application device manufacturer. SARA-R4 series modules are certified according to all capabilities and options stated in the Protocol Implementation Conformance Statement document (PICS) of the module. The PICS, according to the 3GPP TS 36.521-2 [12] and 3GPP TS 36.523-2 [13], is a statement of the implemented and supported capabilities and options of a device. The PICS document of the application device integrating SARA-R4 series modules must be updated from the module PICS statement if any feature stated as supported by the module in its PICS document is not implemented or disabled in the application device. For more details regarding the AT commands settings that affect the PICS, see the SARA-R4 series AT Commands Manual [1]. Check the specific settings required for mobile network operators approvals as they may differ from the AT commands settings defined in the module as integrated in the application device. UBX-16029218 - R03 Approvals Page 76 of 94 SARA-R4 series - System Integration Manual 4.2 US Federal Communications Commission notice United States Federal Communications Commission (FCC) IDs: u-blox SARA-R404M cellular modules: XPY2AGQN1NNN u-blox SARA-R410M cellular modules: XPY2AGQN4NNN 4.2.1 Safety warnings review the structure Equipment for building-in. The requirements for fire enclosure must be evaluated in the end product The clearance and creepage current distances required by the end product must be withheld when the module is installed The cooling of the end product shall not negatively be influenced by the installation of the module Excessive sound pressure from earphones and headphones can cause hearing loss No natural rubbers, hygroscopic materials, or materials containing asbestos are employed 4.2.2 Declaration of Conformity This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: this device may not cause harmful interference this device must accept any interference received, including interference that may cause undesired operation Radiofrequency radiation exposure Information: this equipment complies with radiation exposure limits prescribed for an uncontrolled environment for fixed and mobile use conditions. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the body of the user or nearby persons. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as authorized in the certification of the product. The gain of the system antenna(s) used for the SARA-R4 series modules (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed the value specified in the FCC Grant for mobile and fixed or mobile operating configurations: o SARA-R404M modules: 13 dBi in 750 MHz, i.e. LTE FDD-13 band SARA-R410M modules: o 3.67 dBi in 700 MHz, i.e. LTE FDD-12 band 4.10 dBi in 850 MHz, i.e. LTE FDD-5 band 6.74 dBi in 1700 MHz, i.e. LTE FDD-4 band 7.12 dBi in 1900 MHz, i.e. LTE FDD-2 band UBX-16029218 - R03 Approvals Page 77 of 94 SARA-R4 series - System Integration Manual 4.2.3 Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by u-blox could void the user's authority to operate the equipment. Manufacturers of mobile or fixed devices incorporating the SARA-R4 series modules are authorized to use the FCC Grants of the SARA-R4 series modules for their own final products according to the conditions referenced in the certificates. The FCC Label shall in the above case be visible from the outside, or the host device shall bear a second label stating: "Contains FCC ID: XPY2AGQN1NNN" resp. "Contains FCC ID: XPY2AGQN4NNN" resp. IMPORTANT: Manufacturers of portable applications incorporating the SARA-R4 series modules are required to have their final product certified and apply for their own FCC Grant related to the specific portable device. This is mandatory to meet the SAR requirements for portable devices. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Additional Note: as per 47CFR15.105 this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consultant the dealer or an experienced radio/TV technician for help UBX-16029218 - R03 Approvals Page 78 of 94 SARA-R4 series - System Integration Manual 4.3 Innovation, Science and Economic Development Canada notice ISED Canada (formerly known as IC - Industry Canada) Certification Numbers: u-blox SARA-R410M cellular modules: 4.3.1 8595A-2AGQN4NNN Declaration of Conformity This device complies with Part 15 of the FCC rules and with the ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: this device may not cause harmful interference this device must accept any interference received, including interference that may cause undesired operation Radiofrequency radiation exposure Information: this equipment complies with radiation exposure limits prescribed for an uncontrolled environment for fixed and mobile use conditions. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the body of the user or nearby persons. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except as authorized in the certification of the product. The gain of the system antenna(s) used for the SARA-R4 series modules (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed the value stated in the IC Grant for mobile and fixed or mobile operating configurations: o SARA-R410M modules: 4.3.2 3.67 dBi in 700 MHz, i.e. LTE FDD-12 band 4.10 dBi in 850 MHz, i.e. LTE FDD-5 band 6.74 dBi in 1700 MHz, i.e. LTE FDD-4 band 7.12 dBi in 1900 MHz, i.e. LTE FDD-2 band Modifications The ISED Canada requires the user to be notified that any changes or modifications made to this device that are not expressly approved by u-blox could void the user's authority to operate the equipment. Manufacturers of mobile or fixed devices incorporating the SARA-R4 series modules are authorized to use the ISED Canada Certificates of the SARA-R4 series modules for their own final products according to the conditions referenced in the certificates. The ISED Canada Label shall in the above case be visible from the outside, or the host device shall bear a second label stating: "Contains IC: 8595A-2AGQN4NNN" resp. Innovation, Science and Economic Development Canada (ISED) Notices This Class B digital apparatus complies with Canadian CAN ICES-3(B) / NMB-3(B). Operation is subject to the following two conditions: o this device may not cause interference this device must accept any interference, including interference that may cause undesired operation of the device UBX-16029218 - R03 Approvals Page 79 of 94 SARA-R4 series - System Integration Manual Radio Frequency (RF) Exposure Information The radiated output power of the u-blox Cellular Module is below the Innovation, Science and Economic Development Canada (ISED) radio frequency exposure limits. The u-blox Cellular Module should be used in such a manner such that the potential for human contact during normal operation is minimized. This device has been evaluated and shown compliant with the ISED RF Exposure limits under mobile exposure conditions (antennas are greater than 20 cm from a person's body). This device has been certified for use in Canada. Status of the listing in the ISED’s REL (Radio Equipment List) can be found at the following web address: http://www.ic.gc.ca/app/sitt/reltel/srch/nwRdSrch.do?lang=eng Additional Canadian information on RF exposure also can be found at the following web address: http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf08792.html IMPORTANT: Manufacturers of portable applications incorporating the SARA-R410M modules are required to have their final product certified and apply for their own Industry Canada Certificate related to the specific portable device. This is mandatory to meet the SAR requirements for portable devices. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Avis d'Innovation, Sciences et Développement économique Canada (ISDE) Cet appareil numérique de classe B est conforme aux normes canadiennes CAN ICES-3(B) / NMB-3(B). Son fonctionnement est soumis aux deux conditions suivantes: o cet appareil ne doit pas causer d'interférence cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement Informations concernant l'exposition aux fréquences radio (RF) La puissance de sortie émise par l’appareil de sans fil u-blox Cellular Module est inférieure à la limite d'exposition aux fréquences radio d'Innovation, Sciences et Développement économique Canada (ISDE). Utilisez l’appareil de sans fil u-blox Cellular Module de façon à minimiser les contacts humains lors du fonctionnement normal. Ce périphérique a été évalué et démontré conforme aux limites d'exposition aux fréquences radio (RF) d'ISDE lorsqu'il est installé dans des produits hôtes particuliers qui fonctionnent dans des conditions d'exposition à des appareils mobiles (les antennes se situent à plus de 20 centimètres du corps d'une personne). Ce périphérique est homologué pour l'utilisation au Canada. Pour consulter l'entrée correspondant à l’appareil dans la liste d'équipement radio (REL - Radio Equipment List) d'ISDE rendez-vous sur: http://www.ic.gc.ca/app/sitt/reltel/srch/nwRdSrch.do?lang=fra Pour des informations supplémentaires concernant l'exposition aux RF au Canada rendez-vous sur: http://www.ic.gc.ca/eic/site/smt-gst.nsf/fra/sf08792.html IMPORTANT: les fabricants d'applications portables contenant les modules SARA-R4 series doivent faire certifier leur produit final et déposer directement leur candidature pour une certification FCC ainsi que pour un certificat ISDE Canada délivré par l'organisme chargé de ce type d'appareil portable. Ceci est obligatoire afin d'être en accord avec les exigences SAR pour les appareils portables. Tout changement ou modification non expressément approuvé par la partie responsable de la certification peut annuler le droit d'utiliser l'équipement. UBX-16029218 - R03 Approvals Page 80 of 94 SARA-R4 series - System Integration Manual UBX-16029218 - R03 Approvals Page 81 of 94 SARA-R4 series - System Integration Manual 5 Product testing 5.1 u-blox in-series production test u-blox focuses on high quality for its products. All units produced are fully tested automatically in production line. Stringent quality control process has been implemented in the production line. Defective units are analyzed in detail to improve the production quality. This is achieved with automatic test equipment (ATE) in production line, which logs all production and measurement data. A detailed test report for each unit can be generated from the system. Figure 42 illustrates typical automatic test equipment (ATE) in a production line. The following typical tests are among the production tests. Digital self-test (firmware download, Flash firmware verification, IMEI programming) Measurement of voltages and currents Adjustment of ADC measurement interfaces Functional tests (serial interface communication, SIM card communication) Digital tests (GPIOs and other interfaces) Measurement and calibration of RF characteristics in all supported bands (such as receiver S/N verification, frequency tuning of reference clock, calibration of transmitter and receiver power levels, etc.) Verification of RF characteristics after calibration (i.e. modulation accuracy, power levels, spectrum, etc. are checked to ensure they are all within tolerances when calibration parameters are applied) Figure 42: Automatic test equipment for module tests UBX-16029218 - R03 Product testing Page 82 of 94 SARA-R4 series - System Integration Manual 5.2 Test parameters for OEM manufacturer Because of the testing done by u-blox (with 100% coverage), an OEM manufacturer does not need to repeat firmware tests or measurements of the module RF performance or tests over analog and digital interfaces in their production test. However, an OEM manufacturer should focus on: Module assembly on the device; it should be verified that: o Soldering and handling process did not damage the module components All module pins are well soldered on device board There are no short circuits between pins Component assembly on the device; it should be verified that: Communication with host controller can be established The interfaces between module and device are working Overall RF performance test of the device including antenna Dedicated tests can be implemented to check the device. For example, the measurement of module current consumption when set in a specified status can detect a short circuit if compared with a “Golden Device” result. In addition, module AT commands can be used to perform functional tests on digital interfaces (communication with host controller, check SIM interface, GPIOs, etc.) or to perform RF performance tests (see the following section 5.2.2 for details). 5.2.1 “Go/No go” tests for integrated devices A “Go/No go” test is typically to compare the signal quality with a “Golden Device” in a location with excellent network coverage and known signal quality. This test should be performed after data connection has been established. These kinds of test may be useful as a “go/no go” test but not for RF performance measurements. This test is suitable to check the functionality of communication with host controller, SIM card as well as power supply. It is also a means to verify if components at antenna interface are well soldered. 5.2.2 RF functional tests The overall RF functional test of the device including the antenna can be performed with basic instruments such as a spectrum analyzer (or an RF power meter) and a signal generator with the assistance of AT+UTEST command over AT command user interface. The AT+UTEST command provides a simple interface to set the module to Rx or Tx test modes ignoring the LTE signaling protocol. The command can set the module into: transmitting mode in a specified channel and power level in all supported modulation schemes and bands receiving mode in a specified channel to returns the measured power level in all supported bands See the SARA-R4 series AT Commands Manual [2] and the End user test Application Note [14], for the AT+UTEST command syntax description and detail guide of usage. UBX-16029218 - R03 Product testing Page 83 of 94 SARA-R4 series - System Integration Manual This feature allows the measurement of the transmitter and receiver power levels to check component assembly related to the module antenna interface and to check other device interfaces from which depends the RF performance. To avoid module damage during transmitter test, a proper antenna according to module specifications or a 50 termination must be connected to the ANT port. To avoid module damage during receiver test, the maximum power level received at the ANT port must meet module specifications. The AT+UTEST command sets the module to emit RF power ignoring LTE signaling protocol. This emission can generate interference that can be prohibited by law in some countries. The use of this feature is intended for testing purpose in controlled environments by qualified user and must not be used during the normal module operation. Follow instructions suggested in u-blox documentation. u-blox assumes no responsibilities for the inappropriate use of this feature. Figure 43 illustrates a typical test setup for such RF functional test. Application Processor SARA-R4 series Cellular antenna Wideband antenna IN Spectrum Analyzer or Power Meter OUT Signal Generator AT commands ANT TX Application Board Application Processor SARA-R4 series AT commands ANT Cellular antenna Wideband antenna RX Application Board Figure 43: Setup with spectrum analyzer or power meter and signal generator for radiated measurements UBX-16029218 - R03 Product testing Page 84 of 94 SARA-R4 series - System Integration Manual Appendix A Migration between SARA-R4 and SARA-G3 A.1 Overview 64 63 62 61 60 59 58 57 56 55 54 50 GND V_INT 49 MIC_P GND DSR 47 RSVD MIC_BIAS DCD 46 RSVD 45 SPK_N DTR 45 RSVD 44 SPK_P RTS 10 44 RSVD 43 GND CTS 11 43 GND 42 SIM_DET TXD 12 42 GPIO5 41 VSIM RXD 13 41 VSIM 40 SIM_RST GND 14 40 SIM_RST 15 39 SIM_IO PWR_ON 15 39 SIM_IO GPIO1 16 38 SIM_CLK GPIO1 16 38 SIM_CLK 37 I2S_RXD VUSB_DET 17 37 RSVD 36 I2S_CLK RESET_N 18 36 RSVD 35 I2S_TXD GPIO6 19 35 RSVD 34 I2S_WA GND 20 34 RSVD 33 RSVD GND 21 33 RSVD GND V_INT 49 RSVD GND 48 RSVD DSR 48 MIC_N RI 47 RSVD RI 47 MIC_GND DCD 46 RSVD DCD 46 45 RSVD DTR 44 RSVD RTS 10 43 GND CTS 11 42 SIM_DET TXD 12 41 VSIM RXD 13 40 SIM_RST GND 14 PWR_ON 80 SARA-G300 SARA-G310 DTR RTS 10 CTS 11 TXD 12 RXD 13 GND 14 PWR_ON 15 39 SIM_IO RSVD 16 38 SIM_CLK RSVD 17 37 RSVD RSVD 17 RESET_N 18 36 RSVD RESET_N 18 RSVD 19 35 RSVD RSVD 19 GND 20 34 RSVD GND 20 GND 21 33 RSVD GND 21 81 82 83 84 Pin 65-96: GND 85 86 91 87 92 88 93 89 94 90 95 96 GND GND EXT32K TXD_AUX RSVD RXD_AUX RSVD RSVD 32K_OUT GND RSVD 22 23 24 25 26 27 28 29 30 31 32 73 74 75 76 77 78 79 80 SARA-G340 SARA-G350 Top View 81 82 83 84 Pin 65-96: GND 85 86 91 87 92 88 93 89 94 90 95 96 22 23 24 25 26 27 28 29 30 31 32 GND Top View 72 GND 79 71 GND 78 GND GND RSVD RI 50 65 66 71 67 72 68 73 69 74 70 75 76 77 78 79 80 SARA-R4 Top View 81 82 83 84 Pin 65-96: GND 85 86 91 87 92 88 93 89 94 90 95 96 22 23 24 25 26 27 28 29 30 31 32 GND GND GND RSVD RSVD VCC USB_D+ VCC 51 SCL 52 USB_D- SDA GND GPIO4 VCC GPIO3 53 77 ANT 48 70 GND 76 GND GND RSVD 69 V_BCKP 75 GND GND 49 68 VCC 74 GND VCC 50 67 VCC 73 GND VCC 51 66 51 72 ANT_DET VCC 52 65 52 71 GND GND ANT GND GND GND GND GND ANT_DET GND GND 64 63 62 61 60 59 58 57 56 55 54 53 GND GND RSVD DSR VCC TXD_AUX 70 RXD_AUX GND 69 SCL 68 SDA V_INT 67 GPIO4 66 GPIO3 GND 65 GPIO2 V_BCKP 64 63 62 61 60 59 58 57 56 55 54 53 GPIO2 GND GND GND GND GND ANT GND GND GND GND GND RSVD GND GND SARA-G3 and SARA-R4 series cellular modules have exactly the same SARA form factor (26.0 x 16.0 mm LGA) with exactly the same 96-pin layout as described in Figure 44, so that the modules can be alternatively mounted on a single application board using exactly the same copper mask, solder mask and paste mask. Figure 44: SARA-G3 series and SARA-R4 series and modules pad layout and pin assignment SARA modules are also form-factor compatible with the u-blox LISA, LARA and TOBY cellular module families: although each has a different form factor, the footprints for the TOBY, LISA, SARA and LARA modules have been developed to ensure layout compatibility. With the u-blox “nested design” solution, any TOBY, LISA, SARA or LARA module can be alternatively mounted on the same space of a single “nested” application board as described in Figure 45. Guidelines in order to implement a nested application board, description of the u-blox reference nested design and comparison between TOBY, LISA, SARA and LARA modules are provided in the Nested Design Application Note [18]. TOBY cellular module LISA cellular module LARA cellular module SARA cellular module Nested application board Figure 45: TOBY, LISA, SARA, LARA modules’ layout compatibility: all modules are accommodated on the same nested footprint UBX-16029218 - R03 Appendix Page 85 of 94 SARA-R4 series - System Integration Manual Figure 31 summarizes the interfaces provided by SARA-G3 and SARA-R4 series modules. • • • • • • • • GNSS RTC sharing • GNSS Tx data ready • GNSS supply enable • • Network indication • • • • • • • • • • • • Other 1.8 V GPIOs • 13/26 MHz output • • 1.8 V digital audio • • • Analog audio I/O • • • 1.8 V DDC SARA-R4 series • • Audio 1.8 V SPI USB 2.0 • 1.8 V UART AUX • 1.8 V UART • SIM detection • Serial 1.8 V / 3.0 V SIM SARA-G340/G350 series SIM 32 kHz output • 32 kHz input • Reset input • System Power-on input • Antenna detection Antenna RF I/O SARA-G300/G310 series Rx diversity input 1.8 V supply Output Antenna RTC supply I/O Power Module supply input Modules F = supported by future product versions Table 30: Summary of SARA-R4 and SARA-G3 series modules interfaces UBX-16029218 - R03 Appendix Page 86 of 94 SARA-R4 series - System Integration Manual A.2 Pin-out comparison between SARA-R4 and SARA-G3 SARA-G3 SARA-R4 Pin No Pin Name Description Pin Name Description GND Ground GND Ground V_BCKP RTC Supply I/O RSVD Reserved GND Ground GND Ground V_INT Interfaces Supply Out Output characteristics: 1.8 V typ, 70 mA max V_INT Interfaces Supply Out Output characteristics: 1.8 V typ, 70 mA max GND Ground GND Ground DSR UART DSR Output 1.8 V, Driver strength: 6 mA DSR UART DSR Output 1.8 V, Driver strength: 2 mA No functional difference RI UART RI Output 1.8 V, Driver strength: 6 mA RI UART RI Output 1.8 V, Driver strength: 2 mA No functional difference DCD UART DCD Output 1.8 V, Driver strength: 6 mA DCD UART DCD Output 1.8 V, Driver strength: 2 mA No functional difference DTR UART DTR Input 1.8 V, Internal pull-up: ~33 k DTR UART DTR Input 1.8 V, Internal pull-up: ~100 k No functional difference 10 RTS UART RTS Input 1.8 V, Internal pull-up:~58 k RTS UART RTS Input 1.8 V, Internal pull-up: ~100 k No functional difference 11 CTS UART CTS Output 1.8 V, Driver strength: 6 mA CTS UART CTS Output 1.8 V, Driver strength: 2 mA No functional difference 12 TXD UART Data Input 1.8 V, Internal pull-up:~18 k TXD UART Data Input 1.8 V, Internal pull-up: ~100 k No functional difference 13 RXD UART Data Output 1.8 V, Driver strength: 6 mA RXD UART Data Output 1.8 V, Driver strength: 2 mA No functional difference 14 GND Ground GND Ground 15 PWR_ON Power-on Input No internal pull-up L-level: -0.10 V – 0.65 V H-level: 2.00 V – 4.50 V ON L-level time: 5 ms min OFF L-level pulse time: Not Available PWR_ON Power-on Input 200 k internal pull-up L-level: -0.30 V – 0.35 V H-level: 1.17 V – 2.10 V ON L-level pulse time: 0.15 s min – 3.2 s max OFF L-level pulse time: 1.5 s min On SARA-R4 series, the module is powered on applying a low pulse on the PWR_ON pin. PWR_ON pin can be used to power off SARA-R4 series modules 16 GPIO1 / RSVD 1.8 V GPIO / Reserved Default: Pin disabled Driver strength: 6 mA GPIO1 1.8 V GPIO Default: Pin disabled Driver strength: 2 mA No functional difference 17 RSVD Reserved VUSB_DET USB Detect Input 5 V, Supply detection USB detection instead of Reserved available on SARA-R4 series 18 RESET_N Reset signal Internal diode & pull-up L-level: -0.30 V – 0.30 V H-level: 2.00 V – 4.70 V Reset L-level pulse time: 50 ms min (SARA-G350/G340) 3 s min (SARA-G300/G310) RESET_N Reset signal 37 k internal pull-up L-level: -0.30 V – 0.35 V H-level: 1.17 V – 2.10 V Reset L-level pulse time: 10 s min On SARA-R4 series, a low level on the RESET_N line triggers an abrupt hardware shutdown of the module 19 RSVD Reserved GPIO6 1.8 V GPIO GPIO available instead of Reserved on SARA-G3 series 20-22 GND Ground GND Ground 23 GPIO2 / RSVD 1.8 V GPIO / Reserved Default: GNSS supply enable Driver strength: 6 mA GPIO2 1.8 V GPIO Default: Pin disabled Driver strength: 2 mA No functional difference 24 GPIO3 / 32K_OUT 1.8 V GPIO / 32 kHz Output Default: GNSS data ready Driver strength: 5 mA GPIO3 1.8 V GPIO Default: Pin disabled Driver strength: 2 mA No functional difference 25 GPIO4 / RSVD 1.8 V GPIO / Reserved Default: GNSS RTC sharing Driver strength: 6 mA GPIO4 1.8 V GPIO Default: Output/Low Driver strength: 2 mA No functional difference 26 SDA / RSVD I2C Data I/O / Reserved 1.8 V, open drain, no internal pull-up SDA I2S Data I/O 1.8 V, open drain, internal pull-up No functional difference 27 SCL / RSVD I2C Clock Output / Reserved 1.8 V, open drain, no internal pull-up SCL I2C Clock Output 1.8 V, open drain, internal pull-up No functional difference UBX-16029218 - R03 Remarks for migration RTC supply not available on SARA-R4 series modules No functional difference Appendix Page 87 of 94 SARA-R4 series - System Integration Manual SARA-G3 SARA-R4 Pin No Pin Name Description Pin Name Description Remarks for migration 28 RXD_AUX Aux UART Data Out 1.8 V USB_D- USB Data I/O (D-) High-Speed USB 2.0 USB instead of Auxiliary UART on SARA-R4 series 29 TXD_AUX Aux UART Data In 1.8 V USB_D+ USB Data I/O (D+) High-Speed USB 2.0 USB instead of Auxiliary UART on SARA-R4 series 30 GND Ground GND Ground 31 RSVD / EXT32K Reserved / 32 kHz Input RSVD Reserved 32 GND Ground GND Ground 33 RSVD Reserved, to be connected to GND 34 I2S_WA / RSVD I S Word Alignment / Reserved 1.8 V 35 I2S_TXD / RSVD I S Data Output / Reserved 1.8 V 36 I2S_CLK / RSVD 37 No functional difference RSVD Reserved, can be connected to GND No functional difference RSVD Reserved Reserved on SARA-R4 series modules RSVD Reserved Reserved on SARA-R4 series modules I S Clock / Reserved 1.8 V RSVD Reserved Reserved on SARA-R4 series modules I2S_RXD / RSVD I2S Data Input / Reserved 1.8 V RSVD Reserved Reserved on SARA-R4 series modules 38 SIM_CLK SIM Clock Output SIM_CLK SIM Clock Output No functional difference 39 SIM_IO SIM Data I/O SIM_IO SIM Data I/O No functional difference 40 SIM_RST SIM Reset Output SIM_RST SIM Reset Output No functional difference 41 VSIM SIM Supply Output VSIM SIM Supply Output No functional difference 42 SIM_DET SIM Detection Input 1.8 V GPIO5 SIM Detection Input 1.8 V No functional difference 43 GND Ground GND Ground 44 SPK_P / RSVD Analog Audio Out (+) / Reserved RSVD Reserved Reserved on SARA-R4 series modules 45 SPK_N / RSVD Analog Audio Out (-) / Reserved RSVD Reserved Reserved on SARA-R4 series modules 46 MIC_BIAS / RSVD Microphone Supply Out / Reserved RSVD Reserved Reserved on SARA-R4 series modules 47 MIC_GND / RSVD Microphone Ground / Reserved RSVD Reserved Reserved on SARA-R4 series modules 48 MIC_N / RSVD Analog Audio In (-) / Reserved RSVD Reserved Reserved on SARA-R4 series modules 49 MIC_P / RSVD Analog Audio In (+) / Reserved RSVD Reserved Reserved on SARA-R4 series modules 50 GND Ground GND Ground 51-53 VCC Module Supply Input Normal op. range: 3.35 V – 4.5 V Extended op. range: 3.00 V – 4.5 V VCC Module Supply Input Normal op. range: 3.2 V – 4.2 V Extended op. range: 3.0 V – 4.3 V 54-55 GND Ground GND Ground 56 ANT RF Antenna I/O ANT RF Antenna I/O 57-61 GND Ground GND Ground 62 ANT_DET / RSVD Antenna Detection Input / Reserved ANT_DET Antenna Detection Input 63-96 GND Ground GND Ground No functional difference No functional difference No functional difference Table 31: SARA-R4 and SARA-G4 series modules pin assignment with remarks for migration For further details regarding the characteristics, capabilities, usage or settings applicable for each interface of the cellular modules, see the SARA-R4 series Data Sheet [1], the SARA-G3 series Data Sheet [16], the SARA-G3 / SARA-U2 series System Integration Manual [17], the SARA-R4 series AT Commands Manual [2] and the Nested Design Application Note [18]. UBX-16029218 - R03 Appendix Page 88 of 94 SARA-R4 series - System Integration Manual A.3 Schematic for SARA-R4 and SARA-G3 integration Figure 46 shows an example of schematic diagram where a SARA-R3 or a SARA-G3 series module can be integrated into the same application board, using all the available interfaces and functions of the modules. The different mounting options for the external parts are highlighted in different colors as described in the legend, according to the interfaces supported by the relative modules. SARA-R4 / SARA-G3 0Ω for SARA-G3 modules 15pF 3V8 51 VCC ANT 56 ANT_DET 62 52 VCC 39nH 53 VCC 330µF 100nF 10nF 56pF 15pF V_BCKP GND 10k 82nH 27pF V_INT 0Ω RTC + back-up 100µF V_BCKP GND External Antenna Connector 33pF ESD 0Ω for SARA-G300 / SARA-G310 SIM Card Connector 1k TP V_INT SIM_DET / GPIO5 42 SW1 SW2 VSIM 41 CCVCC (C1) SIM_IO 39 CCIO (C7) SIM_CLK 38 CCCLK (C3) SIM_RST 40 CCVPP (C6) Application Processor 100k TP Open Drain Output 15 PWR_ON CCRST (C2) 47pF 470k TP Open Drain Output 47pF 47pF 47pF 100nF 18 RESET_N IN 1.8V UART DTE TXD 0Ω TP 0Ω TP 12 TXD 13 RXD 10 RTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD RTS CTS 0Ω TP 0Ω TP GND GND RSVD / GPIO2 23 RSVD / SDA 26 RSVD / SCL 27 32K_OUT / GPIO3 24 RSVD / GPIO4 25 D+ D- 0Ω TP 0Ω GND GND 35 37 RSVD / I2S_CLK 36 RSVD / I2S_WA 34 RSVD / GPIO6 19 RSVD / MIC_BIAS 46 RSVD / MIC_P 49 RSVD / MIC_N 48 RSVD / MIC_GND 47 RSVD / SPK_P 44 RSVD / SPK_N 45 SDA SDA SCL SCL TP 0Ω TP 0Ω TP 0Ω TP 0Ω RXD 0Ω TP 0Ω TP 29 TXD_AUX / USB_D+ 28 RXD_AUX / USB_D- GND GND MICBIAS MICLP SDIN MICLN SDOUT Network Indicator 16 33 RSVD / GPIO1 RSVD 100nF 1µF 1µF 10µF 2.2k Microphone EMI 1µF EMI 1µF 2.2k MICGND 27pF 27pF ESD ESD Speaker BCLK MCLK LRCLK OUTP MCLK OUTN EMI EMI 27pF 27pF 2.2k 10uF 3V8 V_INT VDD IRQn 1.8V UART DTE TXD TxD1 Audio Codec 10k 31 RSVD / I2S_TXD 0Ω EXTINT0 V_INT 0Ω RSVD / I2S_RXD 4.7k SCL2 TP 17 RSVD / VUSB_DET 0Ω 4.7k GND SDA2 USB 2.0 Host VBUS VCC OUT SHDN 47k EXT32K / RSVD u-blox 1.8V GNSS Receiver LDO Regulator 1V8_GPS 3V8 RXD GND (C5) ESD ESD ESD ESD ESD ESD 2.2k ESD ESD 2.2k 100nF LEGEND 100nF 2.2k Mount for SARA-G3 and SARA-R4 modules Mount for SARA-G3 modules Mount for SARA-R4 modules Mount for SARA-G300 / SARA-G310 modules Mount for SARA-G340 / SARA-G350 modules Mount for SARA-G340 / SARA-G350 / SARA-R4 modules Figure 46: Example of complete schematic diagram to integrate SARA-R4 modules and SARA-G3 modules on the same application board, using all the available interfaces / functions of the modules UBX-16029218 - R03 Appendix Page 89 of 94 SARA-R4 series - System Integration Manual B Glossary 3GPP 3rd Generation Partnership Project 8-PSK 8 Phase-Shift Keying modulation 16QAM 16-state Quadrature Amplitude Modulation 64QAM 64-state Quadrature Amplitude Modulation ACM Abstract Control Model ADC Analog to Digital Converter AP Application Processor ASIC Application-Specific Integrated Circuit AT AT Command Interpreter Software Subsystem, or attention BAW Bulk Acoustic Wave CSFB Circuit Switched Fall-Back DC Direct Current DCE Data Communication Equipment DDC Display Data Channel interface DL Down-Link (Reception) DRX Discontinuous Reception DSP Digital Signal Processing DTE Data Terminal Equipment ECM Ethernet networking Control Model EDGE Enhanced Data rates for GSM Evolution EMC Electro-Magnetic Compatibility EMI Electro-Magnetic Interference ESD Electro-Static Discharge ESR Equivalent Series Resistance E-UTRA Evolved Universal Terrestrial Radio Access FDD Frequency Division Duplex FEM Front End Module FOAT Firmware Over AT commands FOTA Firmware Over The Air FTP File Transfer Protocol FW Firmware GND Ground GNSS Global Navigation Satellite System GPIO General Purpose Input Output GPRS General Packet Radio Service GPS Global Positioning System HBM Human Body Model HSIC High Speed Inter Chip HSDPA High Speed Downlink Packet Access HSUPA High Speed Uplink Packet Access HTTP HyperText Transfer Protocol HW Hardware I/Q In phase and Quadrature I2C Inter-Integrated Circuit interface I2S Inter IC Sound interface IP Internet Protocol LDO Low-Dropout LGA Land Grid Array UBX-16029218 - R03 Appendix Page 90 of 94 SARA-R4 series - System Integration Manual LNA Low Noise Amplifier LPDDR Low Power Double Data Rate synchronous dynamic RAM memory LTE Long Term Evolution M2M Machine-to-Machine MBIM Mobile Broadband Interface Model MIMO Multi-Input Multi-Output N/A Not Applicable N.A. Not Available NCM Network Control Model OEM Original Equipment Manufacturer device: an application device integrating a u-blox cellular module OTA Over The Air PA Power Amplifier PCM Pulse Code Modulation PCN / IN Product Change Notification / Information Note PCS Personal Communications Service PFM Pulse Frequency Modulation PMU Power Management Unit PWM Pulse Width Modulation QPSK Quadrature Phase Shift Keying RF Radio Frequency RMII Reduced Media Independent Interface RNDIS Remote Network Driver Interface Specification RSE Radiated Spurious Emission RTC Real Time Clock SAW Surface Acoustic Wave SDIO Secure Digital Input Output SIM Subscriber Identification Module SMS Short Message Service SRF Self Resonant Frequency SSL Secure Socket Layer TBD To Be Defined TCP Transmission Control Protocol TDD Time Division Duplex TDMA Time Division Multiple Access TIS Total Isotropic Sensitivity TP Test-Point TRP Total Radiated Power UART Universal Asynchronous Receiver-Transmitter UDP User Datagram Protocol UICC Universal Integrated Circuit Card UL Up-Link (Transmission) UMTS Universal Mobile Telecommunications System USB Universal Serial Bus VCO Voltage Controlled Oscillator VoLTE Voice over LTE VSWR Voltage Standing Wave Ratio Wi-Fi Wireless Local Area Network (IEEE 802.11 short range radio technology) WLAN Wireless Local Area Network (IEEE 802.11 short range radio technology) WWAN Wireless Wide Area Network (GSM / UMTS / LTE cellular radio technology) UBX-16029218 - R03 Appendix Page 91 of 94 SARA-R4 series - System Integration Manual Related documents [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] u-blox SARA-R4 series Data Sheet, u-blox Document UBX-16024152 u-blox SARA-R4 series AT Commands Manual, Docu No UBX-17003787 u-blox EVK-R4xx User Guide Universal Serial Bus Revision 2.0 specification, http://www.usb.org/developers/docs/usb20_docs/ ITU-T Recommendation V.24 - 02-2000 - List of definitions for interchange circuits between Data Terminal Equipment (DTE) and Data Circuit-terminating Equipment (DCE), http://www.itu.int/rec/T-REC-V.24-200002-I/en 3GPP TS 27.007 - AT command set for User Equipment (UE) 3GPP TS 27.005 - Use of Data Terminal Equipment - Data Circuit terminating; Equipment (DTE - DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) 3GPP TS 27.010 - Terminal Equipment to User Equipment (TE-UE) multiplexer protocol I C-bus specification and user manual - Rev. 5 - 9 October 2012 - NXP Semiconductors, http://www.nxp.com/documents/user_manual/UM10204.pdf GSM Association TS.09 - Battery Life Measurement and Current Consumption Technique, http://www.gsma.com/newsroom/wp-content/uploads/TS.09_v9.0.pdf 3GPP TS 36.521-1 - Evolved Universal Terrestrial Radio Access; User Equipment conformance specification; Radio transmission and reception; Part 1: Conformance Testing 3GPP TS 36.521-2 - Evolved Universal Terrestrial Radio Access (E-UTRA); User Equipment conformance specification; Radio transmission and reception; Part 2: Implementation Conformance Statement (ICS) 3GPP TS 36.523-2 - Evolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC); User Equipment conformance specification; Part 2: Implementation Conformance Statement (ICS) u-blox End user test Application Note, Docu No UBX-13001922 u-blox Package Information Guide, Docu No UBX-14001652 u-blox SARA-G3 series Data Sheet, Docu No UBX-13000993 u-blox SARA-G3 / SARA-U2 series System Integration Manual, Docu No UBX- 13000995 u-blox Nested Design Application Note, Docu No UBX-16007243 Some of the above documents can be downloaded from u-blox web-site (http://www.u-blox.com/). UBX-16029218 - R03 Related documents Page 92 of 94 SARA-R4 series - System Integration Manual Revision history Revision Date Name Status / Comments R01 31-Jan-2017 sfal Initial release for SARA-R4 series modules R02 05-May-2017 sfal / sses Updated supported features and characteristics Extended document applicability to SARA-R410M-01B product version R03 24-May-2017 sses Updated supported features and electrical characteristics UBX-16029218 - R03 Revision history Page 93 of 94 SARA-R4 series - System Integration Manual Contact For complete contact information visit us at http://www.u-blox.com/ u-blox Offices North, Central and South America u-blox America, Inc. Phone: +1 703 483 3180 E-mail: info_us@u-blox.com Regional Office West Coast: Phone: +1 408 573 3640 E-mail: info_us@u-blox.com Technical Support: Phone: +1 703 483 3185 E-mail: support_us@u-blox.com Headquarters Europe, Middle East, Africa u-blox AG Phone: E-mail: Support: +41 44 722 74 44 info@u-blox.com support@u-blox.com Asia, Australia, Pacific u-blox Singapore Pte. Ltd. Phone: +65 6734 3811 E-mail: info_ap@u-blox.com Support: support_ap@u-blox.com Regional Office Australia: Phone: +61 2 8448 2016 E-mail: info_anz@u-blox.com Support: support_ap@u-blox.com Regional Office China (Beijing): Phone: +86 10 68 133 545 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Chongqing): Phone: +86 23 6815 1588 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shanghai): Phone: +86 21 6090 4832 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shenzhen): Phone: +86 755 8627 1083 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office India: Phone: +91 80 4050 9200 E-mail: info_in@u-blox.com Support: support_in@u-blox.com Regional Office Japan (Osaka): Phone: +81 6 6941 3660 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Japan (Tokyo): Phone: +81 3 5775 3850 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Korea: Phone: +82 2 542 0861 E-mail: info_kr@u-blox.com Support: support_kr@u-blox.com Regional Office Taiwan: Phone: +886 2 2657 1090 E-mail: info_tw@u-blox.com Support: support_tw@u-blox.com UBX-16029218 - R03 Contact Page 94 of 94
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 94 Language : en-US Tagged PDF : Yes Title : SARA-R4 series System Integration Manual Author : u-blox AG Subject : System Integration Manual Creator : Microsoft® Word 2010 Create Date : 2017:06:16 15:34:25-07:00 Modify Date : 2017:06:16 15:34:25-07:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools