locate, communicate, accelerate SARA-G3 series GSM/GPRS modules System Integration Manual Abstract This document describes the features and the system integration of SARA-G3 series GSM/GPRS wireless modules. These modules are complete and cost efficient solutions offering up to quad-band GSM/GPRS voice and/or data transmission technology in a compact form factor. www.u-blox.com 26.0 x 16.0 x 3.0 mm SARA-G3 series - System Integration Manual Document Information Title SARA-G3 series Subtitle GSM/GPRS modules Document type System Integration Manual Document number UBX-13000995 Document revision A1 Document status Advanced InformationPreliminary Document status information Objective This document contains target values. Revised and supplementary data will be published Specification later. Advance This document contains data based on early testing. Revised and supplementary data will Information be published later. This document contains data from product verification. Revised and supplementary data Preliminary may be published later. Released This document contains the final product specification. This document applies to the following products: Name Type number Firmware version PCN / IN SARA-G300 SARA-G310 SARA-G350 SARA-G350 ATEX SARA-G300-00S-00 SARA-G310-00S-00 SARA-G350-00S-00 SARA-G350-00X-00 08.58 08.58 08.49 08.49 GSM.G2-TN-13007 GSM.G2-TN-13007 GSM.G2-TN-13002 GSM.G2-TN-13002 This document and the use of any information contained therein, is subject to the acceptance of the u-blox terms and conditions. They can be downloaded from www.u-blox.com. u-blox makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. u-blox reserves all rights to this document and the information contained herein. Reproduction, use or disclosure to third parties without express permission is strictly prohibited. Copyright © 2013, u-blox AG. u-blox® is a registered trademark of u-blox Holding AG in the EU and other countries. Trademark Notice Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or oth er countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. UBX-13000995 - A1 Page 2 of 161 Formatted: English (U.S.) SARA-G3 series - System Integration Manual Preface u-blox Technical Documentation As part of our commitment to customer support, u-blox maintains an extensive volume of technical documentation for our products. In addition to our product-specific technical data sheets, the following manuals are available to assist u-blox customers in product design and development. AT Commands Manual: This document provides the description of the supported AT commands by the SARA-G3 series modules to verify all implemented functionalities. System Integration Manual: This manual provides hardware design instructions and information on how to set up production and final product tests. Application Note: document provides general design instructions and information that applies to all u-blox Wireless modules. See Related documents section for a list of Application Notes related to your Wireless Module. How to use this Manual The SARA-G3 series System Integration Manual provides the necessary information to successfully design in and configure these u-blox wireless modules. This manual has a modular structure. It is not necessary to read it from the beginning to the end. The following symbols are used to highlight important information within the manual: An index finger points out key information pertaining to module integration and performance. A warning symbol indicates actions that could negatively impact or damage the module. Questions If you have any questions about u-blox Wireless Integration: Read this manual carefully. Contact our information service on the homepage http://www.u-blox.com Read the questions and answers on our FAQ database on the homepage http://www.u-blox.com Technical Support Worldwide Web Our website (www.u-blox.com) is a rich pool of information. Product information, technical documents and helpful FAQ can be accessed 24h a day. By E-mail Contact the nearest of the Technical Support offices by email. Use our service pool email addresses rather than any personal email address of our staff. This makes sure that your request is processed as soon as possible. You will find the contact details at the end of the document. Helpful Information when Contacting Technical Support When contacting Technical Support, have the following information ready: Module type (e.g. SARA-G350) and firmware version Module configuration Clear description of your question or the problem A short description of the application Your complete contact details UBX-13000995 - A1 Advanced InformationPreliminary Preface Page 3 of 161 SARA-G3 series - System Integration Manual Contents Preface ................................................................................................................................3 Contents..............................................................................................................................4 System description ....................................................................................................... 8 1.1 Overview .............................................................................................................................................. 8 1.2 Architecture ........................................................................................................................................ 10 1.2.1 Internal blocks ............................................................................................................................. 11 1.3 1.4 Pin-out ............................................................................................................................................... 12 Operating modes ................................................................................................................................ 16 1.5 Supply interfaces ................................................................................................................................ 18 1.5.1 1.5.2 Module supply input (VCC) ......................................................................................................... 18 RTC supply input/output (V_BCKP) .............................................................................................. 25 1.5.3 Interfaces supply output (V_INT) .................................................................................................. 26 1.6 System function interfaces .................................................................................................................. 27 1.6.1 Module power-on ....................................................................................................................... 27 1.6.2 Module power-off ....................................................................................................................... 28 1.6.3 1.6.4 Module reset ............................................................................................................................... 29 External 32 kHz signal input (EXT32K) ......................................................................................... 30 1.6.5 Internal 32 kHz signal output (32K_OUT) .................................................................................... 30 1.7 Antenna interface ............................................................................................................................... 31 1.7.1 Antenna RF interface (ANT) ......................................................................................................... 31 1.7.2 Antenna detection interface (ANT_DET) ...................................................................................... 32 1.8 SIM interface ...................................................................................................................................... 32 1.8.1 (U)SIM card interface ................................................................................................................... 32 1.8.2 SIM card detection interface (SIM_DET) ....................................................................................... 32 1.9 Serial interfaces .................................................................................................................................. 33 1.9.1 Asynchronous serial interface (UART)........................................................................................... 33 1.9.2 Auxiliary asynchronous serial interface (UART AUX) ..................................................................... 43 1.9.3 DDC (I C) interface ...................................................................................................................... 43 1.10 Audio interface ............................................................................................................................... 45 1.10.1 Analog audio interface ................................................................................................................ 45 1.10.2 1.10.3 Digital audio interface ................................................................................................................. 47 Voice-band processing system ..................................................................................................... 48 1.11 General Purpose Input/Output (GPIO) ............................................................................................. 50 1.12 1.13 Reserved pins (RSVD) ...................................................................................................................... 52 System features............................................................................................................................... 53 1.13.1 Network indication ...................................................................................................................... 53 1.13.2 1.13.3 Antenna detection ...................................................................................................................... 53 Jamming detection ...................................................................................................................... 53 1.13.4 TCP/IP and UDP/IP ....................................................................................................................... 54 UBX-13000995 - A1 Advanced InformationPreliminary Contents Page 4 of 161 SARA-G3 series - System Integration Manual 1.13.5 1.13.6 FTP .............................................................................................................................................. 54 HTTP ........................................................................................................................................... 54 1.13.7 SMTP........................................................................................................................................... 54 1.13.8 1.13.9 Smart temperature management ................................................................................................. 55 AssistNow clients and GPS/GNSS integration ............................................................................... 57 TM 1.13.10 Hybrid positioning and CellLocate ......................................................................................... 58 1.13.11 1.13.12 Firmware upgrade Over AT (FOAT) .......................................................................................... 60 Firmware upgrade Over The Air (FOTA) .................................................................................... 60 1.13.13 In-Band modem (eCall / ERA-GLONASS) .................................................................................. 61 1.13.14 Power saving ........................................................................................................................... 61 Design-in ..................................................................................................................... 62 2.1 Supply interfaces ................................................................................................................................ 63 2.1.1 2.1.2 Module supply (VCC) .................................................................................................................. 63 RTC supply (V_BCKP) ................................................................................................................... 71 2.1.3 Interface supply (V_INT) ............................................................................................................... 73 2.2 System functions interfaces ................................................................................................................ 74 2.2.1 Module power-on (PWR_ON) ...................................................................................................... 74 2.2.2 Module reset (RESET_N) .............................................................................................................. 75 2.2.3 32 kHz signal (EXT32K and 32K_OUT) ......................................................................................... 76 2.3 Antenna interface ............................................................................................................................... 78 2.3.1 Antenna RF interface (ANT) ......................................................................................................... 78 2.3.2 Antenna detection interface (ANT_DET) ...................................................................................... 83 2.4 SIM interface ...................................................................................................................................... 86 2.5 Serial interfaces .............................................................................................................................. 9493 2.5.1 2.5.2 Asynchronous serial interface (UART)....................................................................................... 9493 Auxiliary asynchronous serial interface (UART AUX) ................................................................. 9796 2.5.3 DDC (I C) interface .................................................................................................................. 9998 2.6 Audio Interface ........................................................................................................................... 102101 2.6.1 Analog Audio interface ....................................................................................................... 102101 2.6.2 Digital Audio interface ......................................................................................................... 108107 2.7 2.8 General Purpose Input/Output (GPIO) ......................................................................................... 109108 Reserved pins (RSVD) .................................................................................................................. 111110 2.9 Module placement...................................................................................................................... 111110 2.10 2.11 Module footprint and paste mask ........................................................................................... 112111 Thermal guidelines .................................................................................................................. 113112 2.12 ESD guidelines ........................................................................................................................ 115114 2.12.1 2.12.2 ESD immunity test overview ................................................................................................ 115114 ESD immunity test of u-blox SARA-G3 series reference designs ........................................... 115114 2.12.3 ESD application circuits ........................................................................................................ 116115 2.13 SARA-G350 ATEX integration in explosive atmospheres applications ...................................... 118117 2.13.1 General guidelines ............................................................................................................... 118117 2.13.2 Guidelines for VCC supply circuit design ............................................................................. 119118 2.13.3 Guidelines for antenna RF interface design .......................................................................... 120119 UBX-13000995 - A1 Advanced InformationPreliminary Contents Page 5 of 161 SARA-G3 series - System Integration Manual 2.14 2.15 2.15.1 Schematic checklist ............................................................................................................. 123122 2.15.2 2.15.3 Layout checklist ................................................................................................................... 124123 Antenna checklist ................................................................................................................ 124123 Handling and soldering ..................................................................................... 125124 3.1 3.2 Packaging, shipping, storage and moisture preconditioning ....................................................... 125124 Soldering .................................................................................................................................... 125124 3.2.1 Soldering paste.................................................................................................................... 125124 3.2.2 3.2.3 Reflow soldering ................................................................................................................. 125124 Optical inspection ................................................................................................................ 127126 3.2.4 Cleaning .............................................................................................................................. 127126 3.2.5 3.2.6 Repeated reflow soldering ................................................................................................... 127126 Wave soldering.................................................................................................................... 127126 3.2.7 Hand soldering .................................................................................................................... 127126 3.2.8 3.2.9 Rework................................................................................................................................ 127126 Conformal coating .............................................................................................................. 127126 3.2.10 Casting................................................................................................................................ 128127 3.2.11 3.2.12 Grounding metal covers ...................................................................................................... 128127 Use of ultrasonic processes .................................................................................................. 128127 Approvals ............................................................................................................ 129128 4.1 Product certification approval overview....................................................................................... 129128 4.2 Federal Communications Commission and Industry Canada notice ............................................. 130129 4.2.1 4.2.2 Safety Warnings review the structure .................................................................................. 130129 Declaration of Conformity – United States only ................................................................... 130129 4.2.3 Modifications ...................................................................................................................... 130129 4.3 4.4 Schematic for SARA-G3 series module integration .................................................................. 121120 Design-in checklist .................................................................................................................. 123122 R&TTED and European Conformance CE mark ........................................................................... 133131 SARA-G350 ATEX conformance for use in explosive atmospheres .............................................. 133131 Product Testing................................................................................................... 135133 5.1 5.2 u-blox in-series production test ................................................................................................... 135133 Test parameters for OEM manufacturer ...................................................................................... 135133 5.2.1 “Go/No go” tests for integrated devices .............................................................................. 136134 5.2.2 Functional tests providing RF operation ............................................................................... 136134 Appendix .................................................................................................................. 139137 A Migration between LISA and SARA modules ................................................... 139137 A.1 A.2 Overview .................................................................................................................................... 139137 Checklist for migration ............................................................................................................... 140138 A.3 Software migration ..................................................................................................................... 142139 A.4 Hardware migration.................................................................................................................... 142139 A.4.1 Supply interfaces ................................................................................................................. 142139 UBX-13000995 - A1 Advanced InformationPreliminary Contents Page 6 of 161 SARA-G3 series - System Integration Manual A.4.2 A.4.3 System functions interfaces ................................................................................................. 143140 Antenna interface ............................................................................................................... 144141 A.4.4 SIM interface ....................................................................................................................... 145142 A.4.5 A.4.6 Serial interfaces ................................................................................................................... 145142 Audio interfaces .................................................................................................................. 146143 A.4.7 GPIO pins ............................................................................................................................ 146143 A.4.8 A.4.9 Reserved pins ...................................................................................................................... 147143 Pin-out comparison between LISA and SARA ....................................................................... 148144 Glossary .............................................................................................................. 153149 Related documents................................................................................................... 155151 Revision history ........................................................................................................ 156152 Contact ...................................................................................................................... 157153 UBX-13000995 - A1 Advanced InformationPreliminary Contents Page 7 of 161 SARA-G3 series - System Integration Manual 1 System description 1.1 Overview SARA-G3 series are versatile 2.5G GSM/GPRS wireless modules in a miniature LGA (Land Grid Array) form factor. SARA-G350 is a full feature quad-band GSM/GPRS wireless module with a comprehensive feature set including an extensive set of internet protocols. SARA-G350 also provides fully integrated access to u-blox GPS/GNSS positioning chips and modules, with embedded A-GPS (AssistNow Online and AssistNow Offline) functionality. SARA-G310 and SARA-G300 are respectively quad-band and dual-band GSM/GPRS wireless modules targeted for high volume cost sensitive applications, providing GSM/GPRS functionalities with a reduced set of additional features to minimize the customer’s total cost of ownership. SARA-G3 wireless modules are certified and approved by the main regulatory bodies and operators, and RIL software for Android and Embedded Windows are available free of charge. SARA-G3 modules are manufactured in ISO/TS 16949 certified sites. Each module is tested and inspected during production. The modules are qualified according to ISO 16750 – Environmental conditions and electrical testing for electrical and electronic equipment for road vehicles. Table 1Table 1 describes a summary of interfaces and features provided by SARA-G3 modules. SARA-G300 • SARA-G310 • • SARA-G350 • • • • • • • • • • • • • • • • SARA-G350 ATEX • • • • • • • • • • • • • • • • • ATEX certification Low power idle-mode TM CellLocate In-band modem FW update over the air (FOTA) FW update over AT (FOAT) AssistNow software GPS/GNSS via Modem SSL FTP, HTTP, SMTP Embedded TCP/UDP Jamming detection Antenna detection Functions Network indication Digital Audio Analog Audio Audio GPIO DDC for u-blox GPS/GNSS receivers USB • SPI UART Interfaces GSM/GPRS dual-band (900/1800) Bands GSM/GPRS quad-band Data Rate GPRS multi-slot class 10 Module • • A = available upon request E = 32 kHz signal at EXT32K input pin is required for low power idle-mode Table 1: SARA-G3 series features summary1 SARA-G350 ATEX modules provide the same feature set of the SARA-G350 modules plus the certification for use in potentially explosive atmospheres. Unless otherwise specified, SARA-G350 refers to all SARA-G350 ATEX modules and SARA-G350 modules. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 8 of 161 SARA-G3 series - System Integration Manual Table 2Table 2 reports a summary of GSM/GPRS characteristics of SARA-G3 series modules. Item SARA-G300 SARA-G310 SARA-G350 GSM/GPRS Protocol Stack 3GPP Release 99 3GPP Release 99 3GPP Release 99 Mobile Station Class Class B2 Class B22 Class B22 Formatted: Superscript GSM/GPRS Bands E-GSM 900 MHz DCS 1800 MHz GSM 850 MHz E-GSM 900 MHz DCS 1800 MHz PCS 1900 MHz GSM 850 MHz E-GSM 900 MHz DCS 1800 MHz PCS 1900 MHz Formatted: Superscript GSM/GPRS Power Class Class 4 (33 dBm) for 900 Class 1 (30 dBm) for 1800 Class 4 (33 dBm) for 850/900 Class 1 (30 dBm) for 1800/1900 Class 4 (33 dBm) for 850/900 Class 1 (30 dBm) for 1800/1900 Packet Switched Data Rate GPRS multi-slot class 103 Coding scheme CS1-CS4 Up to 85.6 kb/s DL4 Up to 42.8 kb/s UL44 GPRS multi-slot class 1033 Coding scheme CS1-CS4 Up to 85.6 kb/s DL44 Up to 42.8 kb/s UL44 GPRS multi-slot class 1033 Coding scheme CS1-CS4 Up to 85.6 kb/s DL44 Up to 42.8 kb/s UL44 Formatted: Superscript Up to 9.6 kb/s DL/UL44 Transparent mode Non transparent mode I to III Up to 9.6 kb/s DL/UL44 Transparent mode Non transparent mode I to III Up to 9.6 kb/s DL/UL44 Transparent mode Non transparent mode I to III Formatted: Superscript Circuit Switched Data Rate Network Operation Modes Formatted: Superscript Formatted: Superscript Formatted: Superscript Formatted: Superscript Formatted: Superscript Table 2: SARA-G3 series GSM/GPRS characteristics summary Formatted: Superscript Formatted: Superscript Formatted: Superscript Device can be attached to both GPRS and GSM services (i.e. Packet Switch and Circuit Switch mode) using one service at a time. GPRS multi-slot class 10 implies a maximum of 4 slots in DL (reception) and 2 slots in UL (transmission) with 5 slots in total. The maximum bit rate of the module depends on the current network settings. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 9 of 161 SARA-G3 series - System Integration Manual 1.2 Architecture 26 MHz 32 kHz 32 kHz PA ANT Power-On SAW Filter Switch RF Transceiver Reset SIM Card SIM Card Detection UART Memory Auxiliary UART Baseband VCC (Supply) V_BCKP (RTC) Power Management V_INT (I/O) Figure 1: SARA-G300 and SARA-G310 modules block diagram 32.768 kHz 26 MHz PA ANT Power-On SAW Filter Switch RF Transceiver Reset SIM Card SIM Card Detection UART Memory Auxiliary UART Baseband VCC (Supply) V_BCKP (RTC) DDC (for GPS/GNSS) Analog Audio Power Management V_INT (I/O) Digital Audio GPIO Antenna Detection Figure 2: SARA-G350 modules block diagram UBX-13000995 - A1 Advanced InformationPreliminary System description Page 10 of 161 SARA-G3 series - System Integration Manual 1.2.1 Internal blocks SARA-G3 modules consist of the following internal sections: RF, Baseband and Power Management. RF section The RF section is composed of the following main elements: RF transceiver performing modulation, up-conversion of the baseband I/Q signals, down-conversion and demodulation of the RF received signals. The RF transceiver includes: Constant gain direct conversion receiver with integrated LNAs Highly linear RF quadrature GMSK demodulator Digital Sigma-Delta transmitter GMSK modulator Fractional-N Sigma-Delta RF synthesizer 3.8 GHz VCO Digital controlled crystal oscillator Transmit module, which amplifies the signals modulated by the RF transceiver and connects the single antenna input/output pin (ANT) of the module to the suitable RX/TX path, via its integrated parts: Power amplifier Antenna switch RX diplexer SAW (band pass) filters 26 MHz crystal, connected to the digital controlled crystal oscillator to perform the clock reference in active-mode or connected-mode Baseband and Power Management section The Baseband and Power Management section is composed of the following main elements: Baseband processor, a mixed signal ASIC which integrates: Microprocessor for controller functions DSP core for GSM/GPRS Layer 1 and audio processing Dedicated peripheral blocks for parallel control of the digital interfaces Audio analog front-end Memory system in a multi-chip package integrating two devices: NOR flash non-volatile memory PSRAM volatile memory Voltage regulators to derive all the system supply voltages from the module supply VCC SARA-G350 modules are provided withhave an internal 32.768 kHz crystal connected to the oscillator of the RTC (Real Time Clock) block that gives the RTC clock reference needed to provide the RTC functions as well as to reach the very low power idle-mode (with power saving configuration enabled by the AT+UPSV command). SARA-G300 and SARA-G310 modules are not provided withdo not have an internal 32.768 kHz crystal: a proper 32 kHz signal must be provided at the EXT32K input pin of the modules to give the RTC clock reference and to provide the RTC functions as well as to reach the very low power idle-mode (with power saving configuration enabled by the AT+UPSV command). The 32K_OUT output pin of SARA-G300 and SARA-G310 modules provides a 32 kHz reference signal suitable only to feed the EXT32K input pin, furnishing the reference clock for the RTC, and allowing low power idle-mode and RTC functions support with modules switched on. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 11 of 161 SARA-G3 series - System Integration Manual 1.3 Pin-out Table 3Table 3 lists the pin-out of the SARA-G3 modules, with pins grouped by function. Function Pin Name Module Pin No I/O Description Remarks Power VCC All 51, 52, 53 Module supply input VCC pins are internally connected each other. VCC supply circuit affects the RF performance and compliance of the device integrating the module with applicable required certification schemes. See section 1.5.11.5.1 for functional description and requirements for the VCC module supply. See section 2.1.12.1.1 for external circuit design-in. GND All 1, 3, 5, 14, N/A 20-22, 30, 32, 43, 50, 54, 55, 57-61, 63-96 Ground GND pins are internally connected each other. External ground connection affects the RF and thermal performance of the device. See section 1.5.11.5.1 for functional description. See section 2.1.12.1.1 for external circuit design-in. V_BCKP All I/O Real Time Clock supply input/output V_BCKP = 2.3 V (typical) generated by internal regulator when valid VCC supply is present. See section 1.5.21.5.2 for functional description. See section 2.1.22.1.2 for external circuit design-in. V_INT All Digital Interfaces supply output V_INT = 1.8 V (typical) generated by internal regulator when the module is switched on. See section 1.5.31.5.3 for functional description. See section 2.1.32.1.3 for external circuit design-in. PWR_ON All 15 Power-on input High input impedance: input voltage level has to be properly fixed, e.g. adding external pull-up. See section 1.6.11.6.1 for functional description. See section 2.2.12.2.1 for external circuit design-in. RESET_N All 18 External reset input A series Schottky diode is integrated in the module as protection, and then an internal 10 k pull-up resistor to V_INT is provided. See section 1.6.31.6.3 for functional description. See section 2.2.22.2.2 for external circuit design-in. EXT32K SARA-G300 SARA-G310 31 32 kHz input Input for RTC reference clock, needed to enter the low power idle-mode and provide RTC functions. See section 1.6.41.6.4 for functional description. See section 2.2.32.2.3 for external circuit design-in. 32K_OUT SARA-G300 SARA-G310 24 32 kHz output 32 kHz output suitable only to feed the EXT32K input giving the RTC reference clock, allowing low power idle-mode and RTC functions support. See section 1.6.51.6.5 for functional description. See section 2.2.32.2.3 for external circuit design-in. ANT All 56 I/O RF input/output for antenna 50 nominal characteristic impedance. Antenna circuit affects the RF performance and compliance of the device integrating the module with applicable required certification schemes. See section 1.7 for functional description and requirements for the antenna RF interface. See section 2.32.3 for external circuit design-in. ANT_DET SARA-G350 62 Input for antenna detection ADC input for antenna detection function. See section 1.7.2 for functional description. See section 2.3.2 for external circuit design-in. System Antenna UBX-13000995 - A1 Advanced InformationPreliminary System description Page 12 of 161 SARA-G3 series - System Integration Manual Function Pin Name Module Pin No I/O Description Remarks SIM VSIM All 41 SIM supply output VSIM = 1.80 V typ. or 2.85 V typ. automatically generated according to the connected SIM type. See section 1.81.8 for functional description. See section 2.42.4 for external circuit design-in. SIM_IO All 39 I/O SIM data Data input/output for 1.8 V / 3 V SIM Internal 4.7 k pull-up to VSIM. See section 1.81.8 for functional description. See section 2.42.4 for external circuit design-in. SIM_CLK All 38 SIM clock 3.25 MHz clock output for 1.8 V / 3 V SIM See section 1.81.8 for functional description. See section 2.42.4 for external circuit design-in. SIM_RST All 40 SIM reset Reset output for 1.8 V / 3 V SIM See section 1.81.8 for functional description. See section 2.42.4 for external circuit design-in. SIM_DET All 42 SIM detection 1.8 V input for SIM presence detection function. See section 1.8.2 for functional description. See section 2.4 for external circuit design-in. RXD All 13 UART data output 1.8 V output, Circuit 104 (RXD) in ITU-T V.24, for AT command, data communication, FOAT. See section 1.9.11.9.1 for functional description. See section 2.5.12.5.1 for external circuit design-in. TXD All 12 UART data input 1.8 V input, Circuit 103 (TXD) in ITU-T V.24, for AT command, data communication, FOAT. Internal active pull-up to V_INT. See section 1.9.11.9.1 for functional description. See section 2.5.12.5.1 for external circuit design-in. CTS All 11 UART clear to send output 1.8 V output, Circuit 106 (CTS) in ITU-T V.24, for AT command, Data communication, FOAT. See section 1.9.11.9.1 for functional description. See section 2.5.12.5.1 for external circuit design-in. RTS All 10 UART ready to send input 1.8 V input, Circuit 105 (RTS) in ITU-T V.24, for AT command, data communication, FOAT. Internal active pull-up to V_INT. See section 1.9.11.9.1 for functional description. See section 2.5.12.5.1 for external circuit design-in. DSR All UART data set ready output 1.8 V output, Circuit 107 (DSR) in ITU-T V.24, for AT command, data communication, FOAT. See section 1.9.11.9.1 for functional description. See section 2.5.12.5.1 for external circuit design-in. RI All UART ring indicator output 1.8 V output, Circuit 125 (RI) in ITU-T V.24, for AT command, data communication, FOAT. See section 1.9.11.9.1 for functional description. See section 2.5.12.5.1 for external circuit design-in. DTR All UART data terminal ready input 1.8 V input, Circuit 108/2 (DTR) in ITU-T V.24, for AT command, data communication, FOAT. Internal active pull-up to V_INT. See section 1.9.11.9.1 for functional description. See section 2.5.12.5.1 for external circuit design-in. DCD All UART data carrier detect output 1.8 V input, Circuit 109 (DCD) in ITU-T V.24, for AT command, data communication, FOAT. See section 1.9.11.9.1 for functional description. See section 2.5.12.5.1 for external circuit design-in. UART UBX-13000995 - A1 Advanced InformationPreliminary System description Page 13 of 161 SARA-G3 series - System Integration Manual Function Pin Name Module Pin No I/O Description Remarks Auxiliary UART RXD_AUX All 28 Auxiliary UART data output 1.8 V output, Circuit 104 (RXD) in ITU-T V.24, for FW upgrade and trace log capture. Access by external test-point is recommended. See section 1.9.21.9.2 for functional description. See section 2.5.22.5.2 for external circuit design-in. TXD_AUX All 29 Auxiliary UART data input 1.8 V input, Circuit 103 (TXD) in ITU-T V.24, for FW upgrade and trace log capture. Access by external test-point is recommended. Internal active pull-up to V_INT. See section 1.9.21.9.2 for functional description. See section 2.5.22.5.2 for external circuit design-in. SCL SARA-G350 27 I2C bus clock line 1.8 V open drain, for the communication with u-blox positioning modules and chips. External pull-up required. See section 1.9.31.9.3 for functional description. See section 2.5.32.5.3 for external circuit design-in. SDA SARA-G350 26 I/O I2C bus data line 1.8 V open drain, for the communication with u-blox positioning modules and chips. External pull-up required. See section 1.9.31.9.3 for functional description. See section 2.5.32.5.3 for external circuit design-in. MIC_BIAS SARA-G350 46 Microphone supply output Supply output (2.2 V typ) for external microphone. See section 1.10.11.10.1 for functional description. See section 2.6.12.6.1 for external circuit design-in. MIC_GND SARA-G350 47 Microphone analog reference Local ground for the external microphone (reference for the analog audio uplink path). See section 1.10.11.10.1 for functional description. See section 2.6.12.6.1 for external circuit design-in. MIC_N SARA-G350 48 Differential analog audio input (negative) Differential analog audio signal input (negative) shared for all the analog uplink path modes: handset, headset, hands-free mode. No internal DC blocking capacitor. See section 1.10.11.10.1 for functional description. See section 2.6.12.6.1 for external circuit design-in. MIC_P SARA-G350 49 Differential analog audio input (positive) Differential analog audio signal input (positive) shared for all the analog uplink path modes: handset, headset, hands-free mode. No internal DC blocking capacitor. See section 1.10.11.10.1 for functional description. See section 2.6.12.6.1 for external circuit design-in. SPK_P SARA-G350 44 Differential analog audio output (positive) Differential analog audio signal output (positive) shared for all the analog downlink path modes: earpiece, headset and loudspeaker mode. See section 1.10.11.10.1 for functional description. See section 2.6.12.6.1 for external circuit design-in. SPK_N SARA-G350 45 Differential analog audio output (negative) Differential analog audio signal output (negative) shared for all the analog downlink path modes: earpiece, headset and loudspeaker mode. See section 1.10.11.10.1 for functional description. See section 2.6.12.6.1 for external circuit design-in. DDC Analog Audio UBX-13000995 - A1 Advanced InformationPreliminary System description Page 14 of 161 SARA-G3 series - System Integration Manual Function Digital Audio GPIO Reserved Pin Name Module Pin No I/O Description Remarks I2S_CLK SARA-G350 36 I S clock 1.8 V clock output for PCM / normal I2S modes. See section 1.10.21.10.2 for functional description. See section 2.6.22.6.2 for external circuit design-in. I2S_RXD SARA-G350 37 I2S receive data 1.8 V data input for PCM / normal I2S modes. Internal active pull-down to GND. See section 1.10.21.10.2 for functional description. See section 2.6.22.6.2 for external circuit design-in. I2S_TXD SARA-G350 35 I2S transmit data 1.8 V data output for PCM / normal I2S modes. See section 1.10.21.10.2 for functional description. See section 2.6.22.6.2 for external circuit design-in. I2S_WA SARA-G350 34 I2S word alignment 1.8 V word al. output for PCM / normal I2S modes See section 1.10.21.10.2 for functional description. See section 2.6.22.6.2 for external circuit design-in. GPIO1 SARA-G350 16 I/O GPIO 1.8 V GPIO by default configured as pad disabled. See section 1.111.11 for functional description. See section 2.72.7 for external circuit design-in. GPIO2 SARA-G350 23 I/O GPIO 1.8 V GPIO by default configured to provide the custom GPS supply enable function. See section 1.111.11 for functional description. See section 2.72.7 for external circuit design-in. GPIO3 SARA-G350 24 I/O GPIO 1.8 V GPIO by default configured to provide the custom GPS data ready function. See section 1.111.11 for functional description. See section 2.72.7 for external circuit design-in. GPIO4 SARA-G350 25 I/O GPIO 1.8 V GPIO by default configured to provide the custom GPS RTC sharing function. See section 1.111.11 for functional description. See section 2.72.7 for external circuit design-in. RSVD All 33 N/A RESERVED pin This pin must be connected to ground. See section 2.82.8 RSVD All 17, 19 N/A RESERVED pin Leave unconnected. See section 2.82.8 RSVD SARA-G350 31 N/A RESERVED pin Internally not connected. Leave unconnected. See section 2.82.8 RSVD SARA-G300 SARA-G310 16, 23, 25-27, 34-37 N/A RESERVED pin Pad disabled. Leave unconnected. See section 2.82.8 RSVD SARA-G300 SARA-G310 44-49, 62 N/A RESERVED pin Leave unconnected. See section 2.82.8 Table 3: SARA-G3 series modules pin definition, grouped by function UBX-13000995 - A1 Advanced InformationPreliminary System description Page 15 of 161 SARA-G3 series - System Integration Manual 1.4 Operating modes SARA-G3 modules have several operating modes. The operating modes defined in Table 4Table 4 and described in detail in Table 5Table 5 provide general guidelines for operation. General Status Operating Mode Definition Power-down Not-Powered Mode Power-Off Mode VCC supply not present or below operating range: module is switched off. VCC supply within operating range and module is switched off. Normal Operation Idle-Mode Module processor core runs with 32 kHz reference, that is generated by: The internal 32 kHz oscillator (SARA-G350) The 32 kHz signal provided at the EXT32K pin (SARA-G300 and SARA-G310) Active-Mode Connected-Mode Module processor core runs with 26 MHz reference generated by the internal oscillator. Voice or data call enabled and processor core runs with 26 MHz reference. Table 4: Module operating modes definition Operating Mode Description Transition between operating modes Not-Powered Mode Module is switched off. Application interfaces are not accessible. Internal RTC timer operates on SARA-G350 modules only if a valid voltage is applied to V_BCKP pin. Additionally, a proper external 32 kHz signal must be fed to EXT32K pin on SARA-G300 / SARA-G310 to let RTC timer running that otherwise is not in operation. When VCC supply is removed, the module enters not-powered mode. When in not-powered mode, the module cannot be switched on by a low level on PWR_ON input or by a preset RTC alarm. When in not-powered mode, the module can be switched on applying VCC supply (refer to 2.2.1) so that the module switches from not-powered to active-mode. Power-Off Mode Module is switched off: normal shutdown by an appropriate power-off event (refer to 1.6.2). Application interfaces are not accessible. Internal RTC timer operates on SARA-G350 modules. A proper external 32 kHz signal must be fed to the EXT32K pin on SARA-G300 / SARA-G310 to let RTC timer running that otherwise is not in operation. When the module is switched off by an appropriate power-off event (refer to 1.6.2), the module enters power-off mode from active-mode. When in power-off mode, the module can be switched on by a low level on PWR_ON input or by a preset RTC alarm (refer to 2.2.1): module switches from power-off to active-mode. When VCC supply is removed, the module switches from power-off mode to not-powered mode. Idle-Mode The module is not ready to communicate with an external device by means of the application interfaces since configured to reduce power consumption. The module automatically enters idle-mode whenever possible if power saving is enabled by the AT+UPSV command (refer to u-blox AT Commands Manual [2]), reducing power consumption (refer to 1.5.1.3). The CTS output line indicates when the UART interface is disabled/enabled due to the module idle/active-mode according to power saving and hardware flow control settings (refer to 1.9.1.3, 1.9.1.4). Power saving configuration is not enabled by default: it can be enabled by the AT+UPSV command (see u-blox AT Commands Manual [2]). A proper 32 kHz signal must be fed to the EXT32K pin of SARA-G300 and SARA-G310 modules to let idle-mode that otherwise cannot be reached (this is not needed for the other SARA-G3 series modules). The module automatically switches from active-mode to idle-mode whenever possible if power saving is enabled (refer to sections 1.5.1.3, 1.9.1.4 and to the u-blox AT Commands Manual [2], AT+UPSV). The module wakes up from idle-mode to active-mode in the following events: Automatic periodic monitoring of the paging channel for the paging block reception according to network conditions (refer to 1.5.1.3, 1.9.1.4) Automatic periodic enable of the UART interface to receive and send data, if the power saving AT command is set to 1 (refer to 1.9.1.4) RTC alarm occurs (refer to u-blox AT Commands Manual [2], AT+CALA command) Data received on UART interface (refer to 1.9.1.4) RTS input line set to the ON state by the DTE if hardware flow control has been disabled by AT&K3 and the power saving AT command is set to 2 (refer to 1.9.1.4) GPS data ready: when the GPIO3 pin is informed by the connected u-blox GPS/GNSS receiver that it is ready to send data via the DDC (I 2C) interface (refer to 1.11, 1.9.3) UBX-13000995 - A1 Advanced InformationPreliminary System description Page 16 of 161 SARA-G3 series - System Integration Manual Operating Mode Description Transition between operating modes Active-Mode The module is ready to communicate with an external device by means of the application interfaces unless power saving configuration is enabled by the AT+UPSV command (refer to sections 1.5.1.3, 1.9.1.4 and to the u-blox AT Commands Manual [2]). When the module is switched on by an appropriate power-on event (refer to 2.2.1), the module enters active-mode from not-powered or power-off mode. If power saving configuration is enabled by the AT+UPSV command, the module automatically switches from active to idle-mode whenever possible and the module wakes up from idle to active-mode in the events listed above (refer to idle to active transition description). When a voice call or a data call is initiated, the module switches from active-mode to connected-mode. Connected-Mode A voice call or a data call is in progress. The module is ready to communicate with an external device by means of the application interfaces unless power saving configuration is enabled by the AT+UPSV command (see sections 1.5.1.3, 1.9.1.4 and the u-blox AT Commands Manual [2][2]). When a voice call or a data call is initiated, the module enters connected-mode from active-mode. When a voice call or a data call is terminated, the module returns to the active-mode. Table 5: Module operating modes description Figure 3Figure 3 describes the transition between the different operating modes. Not powered Remove VCC Switch ON: • Apply VCC Power off Switch ON: • PWR_ON • RTC Alarm Switch OFF: • AT+CPWROFF Incoming/outgoing call or other dedicated device network communication Connected If power saving is enabled and there is no activity for a defined time interval Active Call terminated, communication dropped Idle Any wake up event described in the module operating modes summary table above Figure 3: Operating modes transition UBX-13000995 - A1 Advanced InformationPreliminary System description Page 17 of 161 SARA-G3 series - System Integration Manual 1.5 Supply interfaces 1.5.1 Module supply input (VCC) SARA-G3 modules must be supplied via the three VCC pins that represent the module power supply input. The VCC pins are internally connected to the RF power amplifier and to the integrated Power Management Unit: all supply voltages needed by the module are generated from the VCC supply by integrated voltage regulators, including V_BCKP Real Time Clock supply, V_INT digital interfaces supply and VSIM SIM card supply. During operation, the current drawn by the SARA-G3 series modules through the VCC pins can vary by several orders of magnitude. This ranges from the high peak of current consumption during GSM transmitting bursts at maximum power level in connected-mode (as described in section 1.5.1.2), to the low current consumption during low power idle-mode with power saving enabled (as described in section 1.5.1.3). 1.5.1.1 VCC supply requirements Table 6Table 6 summarizes the requirements for the VCC module supply. Refer to section 2.1.1 for all the suggestions to properly design a VCC supply circuit compliant to the requirements listed in Table 6Table 6. The VCC supply circuit affects the RF compliance of the device integrating SARA-G3 series module with applicable required certification schemes as well as antenna circuit design. Compliance is guaranteed if the VCC requirements summarized in the Table 6Table 6 are fulfilled. Item Requirement Remark VCC nominal voltage Within VCC normal operating range: 3.35 V min. / 4.50 V max. The module cannot be switched on if VCC voltage value is below the normal operating range minimum limit. Ensure that the input voltage at VCC pins is above the minimum limit of the normal operating range for at least more than 3 s after the module switch-on. VCC voltage during normal operation Within VCC extended operating range: 3.00 V min. / 4.50 V max. The module may switch off when VCC voltage drops below the extended operating range minimum limit. Operation above extended operating range maximum limit is not recommended and exposure beyond it may affect device reliability. VCC average current Considerably withstand maximum average current consumption value in connected-mode conditions specified in SARA-G3 series Data Sheet [1][1]. The maximum average current consumption can be greater than the specified value according to the actual antenna mismatching, temperature and VCC voltage. Section 1.5.1.21.5.1.2 describes connected-mode current. Withstand the maximum peak current consumption specified in the SARA-G3 series Data Sheet [1][1]. The specified maximum peak of current consumption occurs during GSM single transmit slot in 850/900 MHz connected-mode, in case of mismatched antenna. Section 1.5.1.21.5.1.2 describes connected-mode current. VCC peak current VCC voltage drop during Tx slots VCC voltage ripple during Tx slots UBX-13000995 - A1 VCC voltage drop values greater than recommended during 2G TDMA transmission slots directly affect the RF compliance with applicable certification schemes. Figure 5Figure 5 describes VCC voltage drop during Tx slots. Lower than 400 mV Lower than 30 mVpp if fripple ≤ 200 kHz Lower than 10 mVpp if 200 kHz < f ripple ≤ 400 kHz Lower than 2 mVpp if fripple > 400 kHz VCC voltage ripple values higher than recommended during 2G transmission directly affect the RF compliance with applicable certification schemes. Figure 5Figure 5 describes VCC voltage ripple during Tx slots. Advanced InformationPreliminary System description Page 18 of 161 Formatted: Font: 8 pt Formatted: Font: 8 pt, French (Canada) Field Code Changed Formatted: Font: 8 pt Field Code Changed Formatted: Font: 8 pt, French (Canada) Formatted: Font: 8 pt Formatted: Font: 8 pt SARA-G3 series - System Integration Manual Item Requirement Remark VCC under/over-shoot at start/end of Tx slots Absent or at least minimized VCC under/over-shoot higher than recommended at the start/end of 2G TDMA transmission slots directly affect the RF compliance with applicable certification schemes. Figure 5Figure 5 describes VCC voltage under/over-shoot at the start/end of Tx slots Table 6: Summary of VCC supply requirements For the additional specific requirement for SARA-G350 ATEX modules integration in potentially explosive atmospheres applications, refer to section 2.13. 1.5.1.2 VCC current consumption in connected-mode When a GSM call is established, the VCC consumption is determined by the current consumption profile typical of the GSM transmitting and receiving bursts. The current consumption peak during a transmission slot is strictly dependent on the transmitted power, which is regulated by the network. If the module is transmitting in GSM talk mode in the 850 or 900 MHz bands, at the maximum RF power control level (approximately 2 W or 33 dBm in the allocated transmit slot/burst) the current consumption can reach up to 1900 mA (with a highly unmatched antenna) for 576.9 µs (width of the transmit slot/burst) with a periodicity of 4.615 ms (width of 1 frame = 8 slots/burst), so with a 1/8 duty cycle according to GSM TDMA (Time Division Multiple Access). If the module is in GSM connected-mode in the 1800 or 1900 MHz bands, the current consumption figures are lower than the one in the 850 or 900 MHz bands, due to 3GPP transmitter output power specifications (refer to SARA-G3 series Data Sheet [1]). During a GSM call, current consumption is in the order of 60-120 mA in receiving or in monitor bursts and is about 10-40 mA in the inactive unused bursts (low current period). The more relevant contribution to determinefactor for determining the average current consumption, is set by the transmitted power in the transmit slot. Figure 4Figure 4 shows an example of the module current consumption profile versus time in GSM talk mode. Current [A] 2.0 1900 mA 1.5 Peak current depends on TX power 1.0 0.5 200 mA 60-120 mA 0.0 RX slot 60-120 mA 10-40 mA unused unused slot slot TX slot unused unused slot slot GSM frame 4.615 ms (1 frame = 8 slots) MON slot unused slot RX slot unused unused slot slot TX slot unused unused slot slot MON slot unused slot Time [ms] GSM frame 4.615 ms (1 frame = 8 slots) Figure 4: VCC current consumption profile versus time during a GSM call (1 TX slot, 1 RX slot) UBX-13000995 - A1 Advanced InformationPreliminary System description Page 19 of 161 Formatted: Font: 8 pt SARA-G3 series - System Integration Manual Figure 5Figure 5 illustrates VCC voltage profile versus time during a GSM call, according to the relative VCC current consumption profile described in Figure 4Figure 4. Voltage overshoot 3.8 V (typ) drop ripple RX slot unused unused slot slot TX slot undershoot unused unused slot slot MON slot unused slot RX slot unused unused slot slot GSM frame 4.615 ms (1 frame = 8 slots) TX slot unused unused slot slot MON slot unused slot Time GSM frame 4.615 ms (1 frame = 8 slots) Figure 5: Description of the VCC voltage profile versus time during a GSM call When a GPRS connection is established, more than one slot can be used to transmit and/or more than one slot can be used to receive. The transmitted power depends on network conditions, which set the peak current consumption, but following the GPRS specifications the maximum transmitted RF power is reduced if more than one slot is used to transmit, so the maximum peak of current is not as high as can be in case of a GSM call. If the module transmits in GPRS multi-slot class 10, in the 850 or 900 MHz bands, at the maximum power control level, the consumption can reach up to 1600 mA (with highly unmatched antenna). This happens for 1.154 ms (width of the 2 Tx slots/bursts) with a periodicity of 4.615 ms (width of 1 frame = 8 slots/bursts), so with a 1/4 duty cycle, according to GSM TDMA. If the module is in GPRS connected-mode in 1800 or 1900 MHz bands, consumption figures are lower than in the 850 or 900 MHz band, due to 3GPP Tx power specifications. Figure 6Figure 6 reports the current consumption profiles in GPRS connected-mode, in the 850 or 900 MHz bands, with 2 slots used to transmit and 1 slot used to receive. Current [A] 2.0 1600 mA 1.5 Peak current depends on TX power 1.0 0.5 200mA 60-120mA 0.0 RX slot 60-120mA 10-40mA unused unused slot slot TX slot TX slot unused slot GSM frame 4.615 ms (1 frame = 8 slots) MON slot unused slot RX slot unused unused slot slot TX slot TX slot unused slot MON slot unused slot Time [ms] GSM frame 4.615 ms (1 frame = 8 slots) Figure 6: VCC current consumption profile versus time during a GPRS connection (2 TX slots, 1 RX slot) UBX-13000995 - A1 Advanced InformationPreliminary System description Page 20 of 161 SARA-G3 series - System Integration Manual 1.5.1.3 VCC current consumption in cyclic idle/active-mode (power saving enabled) The power saving configuration is by default disabled, but it can be enabled using the appropriate AT command (refer to u-blox AT Commands Manual [2], AT+UPSV command). When power saving is enabled, the module automatically enters idle-mode whenever possible, reducing current consumption. During idle-mode, the module processor runs with 32 kHz reference clock frequency. For SARA-G350 modules, the internal oscillator automatically generates the 32 kHz clock. For SARA-G300 and SARA-G310 modules, a valid 32 kHz signal must be properly provided to the EXT32K input pin of the module to let idle-mode, that otherwise cannot be reached (this is not needed for the other SARA-G3 series modules). When power saving is enabled, the module is registered or attached to a network and a voice or data call is not enabled, the module automatically enters idle-mode whenever possible, but it must periodically monitor the paging channel of the current base station (paging block reception), in accordance to GSM system requirements. When the module monitors the paging channel, it wakes up to active-mode, to enable the reception of paging block. In between, the module switches to idle-mode. This is known as GSM discontinuous reception (DRX). The module processor core is activated during the paging block reception, and automatically switches its reference clock frequency from 32 kHz to the 26 MHz used in active-mode. The time period between two paging block receptions is defined by the network. This is the paging period parameter, fixed by the base station through broadcast channel sent to all users on the same serving cell. The time interval between two paging block receptions can be from 470.76 ms (DRX = 2, i.e. width of 2 GSM multiframes = 2 x 51 GSM frames = 2 x 51 x 4.615 ms) up to 2118.42 ms (DRX = 9, i.e. width of 9 GSM multiframes = 9 x 51 frames = 9 x 51 x 4.615 ms). Figure 7Figure 7 roughly describes the current consumption profile of SARA-G350 modules, or specifically of SARA-G300 / SARA-G310 modules when their EXT32K input pin is fed by an external 32 kHz signal with characteristics compliant to the one specified in SARA-G3 series Data Sheet [1], when power saving is enabled. The module is registered with the network, automatically enters the very low power idle-mode, and periodically wakes up to active-mode to monitor the paging channel for paging block reception. Current [mA] 60-120 mA 100 50 300-600 µA Time [s] Current [mA] IDLE MODE ACTIVE MODE 0.44-2.09 s 20-30 ms 100 60-120 mA 50 20-40 mA 4-5 mA 300-600 µA Active Mode Enabled IDLE MODE RX Enabled DSP Enabled 20-30 ms ACTIVE MODE Idle Mode Enabled Time [ms] IDLE MODE Figure 7: VCC current consumption profile versus time of the SARA-G350 modules or the SARA-G300 / SARA-G310 modules (with the EXT32K input fed by a proper external 32 kHz signal), when registered with the network, with power saving enabled: the very low power idle-mode is reached and periodical wake up to active-mode are performed to monitor the paging channel UBX-13000995 - A1 Advanced InformationPreliminary System description Page 21 of 161 SARA-G3 series - System Integration Manual Figure 8Figure 8 roughly describes the current consumption profile of SARA-G300 / SARA-G310 modules when the EXT32K input pin is fed by the 32K_OUT output pin provided by these modules, when power saving is enabled. The module is registered with the network, automatically enters the low power idle-mode and periodically wakes up to active-mode to monitor the paging channel for paging block reception. Current [mA] 60-120 mA 100 50 3-4 mA Time [s] Current [mA] IDLE MODE ACTIVE MODE 0.44-2.09 s 20-30 ms 100 60-120 mA 50 20-40 mA 4-5 mA 3-4 mA Active Mode Enabled IDLE MODE RX Enabled DSP Enabled 20-30 ms ACTIVE MODE Idle Mode Enabled Time [ms] IDLE MODE Figure 8: VCC current consumption profile versus time of the SARA-G300 / SARA-G310 modules (with the EXT32K input pin fed by the 32K_OUT output pin provided by these modules), when registered with the network, with power saving enabled: the low power idle-mode is reached and periodical wake up to active-mode are performed to monitor the paging channel UBX-13000995 - A1 Advanced InformationPreliminary System description Page 22 of 161 SARA-G3 series - System Integration Manual 1.5.1.4 VCC current consumption in fixed active-mode (power saving disabled) Power saving configuration is by default disabled, or it can be disabled using the appropriate AT command (refer to u-blox AT Commands Manual [2], AT+UPSV command). When power saving is disabled, the module does not automatically enter idle-mode whenever possible: the module remains in active-mode. The module processor core is activated during active-mode, and the 26 MHz reference clock frequency is used. Figure 9Figure 9 roughly describes the current consumption profile of SARA-G300 / SARA-G310 modules when the EXT32K input pin is fed by external 32 kHz signal with characteristics compliant to the one specified in SARA-G3 series Data Sheet [1], or by the 32K_OUT output pin provided by these modules, when power saving is disabled. The module is registered with the network, active-mode is maintained, and the receiver and the DSP are periodically activated to monitor the paging channel for paging block reception. Current [mA] 60-120 mA 100 50 3-5 mA Time [s] Current [mA] Paging period 0.47-2.12 s 100 60-120 mA 50 20-40 mA 3-5 mA 3-5 mA RX Enabled DSP Enabled Time [ms] ACTIVE MODE Figure 9: VCC current consumption profile versus time of the SARA-G300 / SARA-G310 modules (with the EXT32K input pin fed by proper external 32 kHz signal or by 32K_OUT output pin), when registered with the network, with power saving disabled: the active-mode is always held, and the receiver and the DSP are periodically activated to monitor the paging channel UBX-13000995 - A1 Advanced InformationPreliminary System description Page 23 of 161 SARA-G3 series - System Integration Manual Figure 10Figure 10 roughly describes the current consumption profile of SARA-G350 modules or the current consumption profile of SARA-G300 / SARA-G310 modules when their EXT32K input is not fed by a signal (left unconnected), when power saving is disabled: the module is registered with the network, active-mode is maintained, and the receiver and the DSP are periodically activated to monitor the paging channel for paging block reception. Current [mA] 60-120 mA 100 50 15-18 mA Time [s] Current [mA] Paging period 0.47-2.12 s 100 60-120 mA 50 20-40 mA 15-18 mA 15-18 mA RX Enabled DSP Enabled Time [ms] ACTIVE MODE Figure 10: VCC current consumption profile versus time of the SARA-G350 modules or the SARA-G300 / SARA-G310 modules (with the EXT32K input pin not fed by any 32 kHz signal), when registered with the network, with power saving disabled: the active-mode is always held, and the receiver and the DSP are periodically activated to monitor the paging channel UBX-13000995 - A1 Advanced InformationPreliminary System description Page 24 of 161 SARA-G3 series - System Integration Manual 1.5.2 RTC supply input/output (V_BCKP) The V_BCKP pin of SARA-G3 modules connects the supply for the Real Time Clock (RTC) and Power-On internal logic. This supply domain is internally generated by a linear LDO regulator integrated in the Power Management Unit, as described in Figure 11Figure 11. The output of this linear regulator is always enabled when the main voltage supply provided to the module through the VCC pins is within the valid operating range, with the module switched off or switched on. SARA-G350 VCC 51 SARA-G300 / SARA-G310 Power Management Baseband Processor Linear LDO RTC VCC 52 VCC 51 Power Management Baseband Processor Linear LDO RTC VCC 52 VCC 53 VCC 53 V_BCKP 2 V_BCKP 2 32 kHz 32 kHz EXT32K 31 Figure 11: SARA-G3 series RTC supply input/output (V_BCKP) and 32 kHz RTC timing reference clock simplified block diagram The RTC provides the module time reference (date and time) that is used to set the wake-up interval during the idle-mode periods between network paging, and is able to make available the programmable alarm functions. The RTC functions are available also in power-down mode when the V_BCKP voltage is within its valid range (specified in the “Input characteristics of Supply/Power pins” table in SARA-G3 series Data Sheet [1]) and, for SARA-G300 / SARA-G310 modules only, when their EXT32K input pin is fed by an external 32.768 kHz signal with proper characteristics (specified in the “EXT32K pin characteristics” table in SARA-G3 series Data Sheet [1]). The RTC can be supplied from an external back-up battery through the V_BCKP, when the main voltage supply is not provided to the module through VCC. This lets the time reference (date and time) run until the V_BCKP voltage is within its valid range, even when the main supply is not provided to the module. The RTC oscillator does not necessarily stop operation (i.e. the RTC counting does not necessarily stop) when V_BCKP voltage value drops below the specified operating range minimum limit (1.00 V): the RTC value read after a system restart could be not reliable, as explained in Table 7Table 7. V_BCKP voltage value RTC value reliability Notes 1.00 V < V_BCKP < 2.40 V RTC oscillator does not stop operation RTC value read after a restart of the system is reliable V_BCKP within operating range 0.05 V < V_BCKP < 1.00 V RTC oscillator does not necessarily stop operation RTC value read after a restart of the system is not reliable V_BCKP below operating range 0.00 V < V_BCKP < 0.05 V RTC oscillator stops operation RTC value read after a restart of the system is reliable V_BCKP below operating range Table 7: RTC value reliability as function of V_BCKP voltage value Consider that the module cannot switch on if a valid voltage is not present on VCC even when the RTC is supplied through V_BCKP (meaning that VCC is mandatory to switch on the module). The RTC has very low power consumption, but is highly temperature dependent. For example at 25 °C, with the V_BCKP voltage equal to the typical output value, the power consumption is approximately 2 µA (refer to the UBX-13000995 - A1 Advanced InformationPreliminary System description Page 25 of 161 SARA-G3 series - System Integration Manual “Input characteristics of Supply/Power pins” table in the SARA-G3 series Data Sheet [1] for the detailed specification), whereas at 70 °C and an equal voltage the power consumption increases to 5-10 µA. If V_BCKP is left unconnected and the module main voltage supply is removed from VCC, the RTC is supplied from the bypass capacitor mounted inside the module. However, this capacitor is not able to provide a long buffering time: within few milliseconds the voltage on V_BCKP will go below the valid range (1 V min). This has no impact on wireless connectivity, as all the module functionalities do not rely on date and time setting. 1.5.3 Interfaces supply output (V_INT) The same 1.8 V voltage domain used internally to supply the digital interfaces of SARA-G3 modules is also available on the V_INT supply output pin, as described in Figure 12Figure 12. SARA-G3 series VCC 51 VCC 52 Power Management Baseband Processor Switching Step-Down Digital I/O Interfaces VCC 53 V_INT 4 Figure 12: SARA-G3 series interfaces supply output (V_INT) simplified block diagram The internal regulator that generates the V_INT supply is a switching step-down converter that is directly supplied from VCC. The voltage regulator output is set to 1.8 V (typical) when the module is switched on and it is disabled when the module is switched off. The switching regulator operates in Pulse Width Modulation (PWM) for greater efficiency at high output loads when the module is in active-mode or in connected-mode. When the module is in low power idle-mode between paging periods and with power saving configuration enabled by the appropriate AT command, it automatically switches to Pulse Frequency Modulation (PFM) for greater efficiency at low output loads. Refer to the u-blox AT Commands Manual [2], +UPSV command. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 26 of 161 SARA-G3 series - System Integration Manual 1.6 System function interfaces 1.6.1 Module power-on The power-on sequence of SARA-G3 series modules is initiated in one of these ways: Rising edge on the VCC pin to a valid voltage as module supply (i.e. applying module supply) Low level on the PWR_ON pin (normally high with external pull-up) for an appropriate time period RTC alarm (i.e. pre-programmed scheduled time by AT+CALA command) 1.6.1.1 Rising edge on VCC When a SARA-G3 module is in the not-powered mode, it can be switched on by applying the VCC supply. The module is switched on when the voltage rises up to the VCC normal operating range minimum limit (3.35 V) starting from a voltage value lower than 2.25 V, and with a proper voltage slope: the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 4 ms to switch on the module. When the VCC voltage is stabilized at its nominal value within the normal operating range, the module can be switched on by a low level on PWR_ON pin (see section 1.6.1.2) or by RTC alarm (see section 1.6.1.3). If the PWR_ON input pin is held low during the VCC apply phase, the SARA-G3 module switches on when voltage rises up to the VCC normal operating range minimum limit (3.35 V). 1.6.1.2 Low level on PWR_ON When a SARA-G3 module is in the power-off mode (i.e. switched off with valid VCC supply maintained), the module can be switched on by forcing a low level on the PWR_ON input pin at least for 5 ms. The electrical characteristics of the PWR_ON input pin are different from the other digital I/O interfaces. The input voltage thresholds are slightly different since the PWR_ON input pin is tolerant of voltages up to the module supply level. The detailed electrical characteristics are described in SARA-G3 series Data Sheet [1]. There is no internal pull-up resistor on the PWR_ON pin: the pin has high input impedance and is weakly pulled to the high level by the internal circuit. Therefore the external circuit must be able to hold the high logic level stable, e.g. providing an external pull-up resistor (for further design-in guidelines refer to section 2.2.1). 1.6.1.3 RTC alarm When a SARA-G3 module is in the power-off mode (i.e. switched off with valid VCC supply maintained) and the RTC timing (32 kHz reference clock) is available, the module can be switched on by an RTC alarm previously programmed by AT command at a scheduled time (refer to the u-blox AT Commands Manual [2], AT+CALA command). The internal RTC block system will then initiate the module boot sequence by instructing the Power Management Unit to turn on power. Also included in this setup is an interrupt signal from the RTC block to indicate to the baseband processor that an RTC event has occurred. The RTC timing is automatically generated by the 32.768 kHz reference clock provided by the internal oscillator on SARA-G350 modules. A valid external 32.768 kHz signal must be provided at the EXT32K input pin of the SARA-G300 / SARA-G310 modules to enable RTC timing, otherwise the switch-on of SARA-G300 / SARA-G310 modules by means of a pre-programmed RTC alarm is not possible (refer to section 1.6.4). 1.6.1.4 Additional considerations The module is switched on when the VCC voltage rises to the normal operating range (i.e. applying module supply): the first time that the module is used, it is switched on in this way. SARA-G3 modules can be switched off by means of the AT+CPWROFF command, entering power-off mode. In this state, the digital input-output pads of the baseband chipset (i.e. all the digital pins of the module) are locked in tri-state (i.e. floating). The power down tri-state function isolates the module pins from the environment, when no proper operation of the outputs can be guaranteed. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 27 of 161 SARA-G3 series - System Integration Manual The module can be switched on from power-off mode by forcing a proper start-up event (e.g. PWR_ON low). After the detection of a start-up event, all the module digital pins are held in tri-state until all the internal LDO voltage regulators are turned on in a defined power-on sequence. Then, as described in Figure 13Figure 13, the baseband core is still held in reset state for a time interval: the internal reset signal (which is not available on a module pin) is still low and all the digital pins of the module are held in reset state. The reset state of all the digital pins is reported in the pin description table of SARA-G3 Series Data Sheet [1]. When the internal signal is released, the configuration of the module interfaces starts: during this phase any digital pin is set in a proper sequence from the reset state to the default operational configuration. Finally, the module is fully ready to operate when all interfaces are configured. Start-up PWR_ON event can be set high Start of interface configuration All interfaces are configured VCC V_BCKP PWR_ON V_INT Internal Reset OFF System State BB Pads State Tristate / Floating 0 ms ON Internal Reset Internal Reset → Operational Operational 5 ms 8 ms ~35 ms ~3 s Figure 13: SARA-G3 series power-on sequence description The Internal Reset signal is not available on a module pin, but the application can monitor the V_INT pin to sense the start of the SARA-G3 series power-on sequence. 1.6.2 Module power-off The correct way to switch off SARA-G3 modules is by means of +CPWROFF AT command (more details in u-blox AT Commands Manual [2]): in this way the current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed. An under-voltage shutdown occurs on SARA-G3 modules when the VCC supply is removed, but in this case the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach cannot be performed. An over-temperature or an under-temperature shutdown occurs when the temperature measured within the wireless module reaches the dangerous area, if the optional Smart Temperature Supervisor feature is activated and configured by the dedicated AT+USTS command. Refer to section 1.13.8 and to the u-blox AT Commands Manual [2] for more details. Figure 14Figure 14 describes the power-off sequence by means of +CPWROFF AT command. When the +CPWROFF AT command is sent, the module starts the switch-off routine replying OK on the AT interface. At the end of the switch-off routine, all digital pins are locked in tri-state by the module and all the internal LDO voltage regulators except the RTC supply (V_BCKP) are turned off in a defined power-off sequence. The module remains in power-off mode as long as a switch on event does not occur (i.e. applying a low level on the PWR_ON pin, or by a pre-programmed RTC alarm), and enters not-powered mode if the supply is removed from the VCC pin. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 28 of 161 SARA-G3 series - System Integration Manual Current parameter settings are stored to the module’s non-volatile memory and a network detach is performed before the OK reply from AT+CPWROFF command. The duration of the switch-off routine phases can largely differ from the values reported in Figure 14Figure 14, depending on the network settings and the concurrent activities of the module performing a network detach. AT+CPWROFF sent to the module OK replied by the module VCC V_BCKP PWR_ON V_INT Internal Reset ON System State BB Pads State Operational 0s OFF Tristate / Floating Operational → Tristate / Floating ~2.5 s ~5 s Figure 14: SARA-G3 series power-off sequence description The Internal Reset signal is not available on a module pin, but the application can monitor the V_INT pin to sense the end of the SARA-G3 series power-off sequence. 1.6.3 Module reset A SARA-G3 module reset can be performed in one of two ways. RESET_N input pin: Forces a low level on the RESET_N input pin, causing an “external” or “hardware” reset. This must be for at least 50 ms on SARA-G350 modules or 3000 ms on SARA-G300 and SARA-G310 modules. This causes an asynchronous reset of the module baseband processor, excluding the integrated Power Management Unit and the RTC internal block: the V_INT interfaces supply is enabled and each digital pin is set in its reset state, the V_BCKP supply and the RTC block are enabled. Forcing an “external” or “hardware” reset, the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach is not performed. AT+CFUN command (refer to the u-blox AT Commands Manual [2] for more details): This command causes an “internal” or “software” reset, which is an asynchronous reset of the module baseband processor. The electrical behavior is the same as that of the “external” or “hardware” reset, but in an “internal” or “software” reset the current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed. After either reset, when RESET_N is released from the low level, the module automatically starts its power-on sequence from the reset state. The reset state of all digital pins is reported in the pin description table in SARA-G3 series Data Sheet [1]. The electrical characteristics of RESET_N are different from the other digital I/O interfaces: the RESET_N input pin is tolerant of voltages up to the module supply level due to the series Schottky diode mounted inside the UBX-13000995 - A1 Advanced InformationPreliminary System description Page 29 of 161 SARA-G3 series - System Integration Manual module on the RESET_N pin. As described in Figure 15Figure 15, the module has an internal pull-up resistor which pulls the line to the high logic level when the RESET_N pin is not forced low from the external. Detailed electrical characteristics are described in SARA-G3 series Data Sheet [1]. SARA-G3 series 1.8 V Baseband Processor 10k RESET_N 18 Reset Input Figure 15: SARA-G3 series reset input (RESET_N) description 1.6.4 External 32 kHz signal input (EXT32K) The EXT32K pin of SARA-G300 / SARA-G310 modules is an input pin that must be fed by a proper 32 kHz signal to make available the reference clock for the Real Time Clock (RTC) timing, used by the module processor when in the low power idle-mode. SARA-G300 / SARA-G310 modules can enter the low power idle-mode only if a proper 32 kHz signal is provided at the EXT32K input pin, with power saving configuration enabled by the AT+UPSV command. In this way the different current consumption figures can be reached with the EXT32K input fed by the 32K_OUT output or by a proper external 32 kHz signal (for more details refer to section 1.5.1.3 and to “Current consumption” section in SARA-G3 series Data Sheet [1]). SARA-G300 / SARA-G310 modules can provide the RTC functions (as RTC timing by AT+CCLK command and RTC alarm by AT+CALA command) only if a proper 32 kHz signal is provided at the EXT32K input pin. The RTC functions will be available only when the module is switched on if the EXT32K input is fed by the 32K_OUT output, or they will be available also when the module is not powered or switched off if the EXT32K input is fed by a proper external 32 kHz signal. SARA-G3 series Data Sheet [1] describes the detailed electrical characteristics of the EXT32K input pin. The 32 kHz reference clock for the RTC timing is automatically generated by the internal oscillator provided on the SARA-G350 modules: the same pin (31) is a reserved (RSVD) pin internally not connected, since an external 32 kHz signal is not needed to enter the low power idle-mode and to provide the RTC functions. 1.6.5 Internal 32 kHz signal output (32K_OUT) The 32K_OUT pin of SARA-G300 / SARA-G310 modules is an output pin that provides a 32 kHz reference signal generated by the module, suitable only to feed the EXT32K input pin of SARA-G300 / SARA-G310 modules, to make available the reference clock for the Real Time Clock (RTC) timing, so that the modules can enter the low power idle-mode and can provide the RTC functions with modules switched on. The 32K_OUT pin does not provide the 32 kHz output signal when the SARA-G300 / SARA-G310 modules are in power down mode: the EXT32K input pin must be fed by an external proper 32 kHz signal to make available the RTC functions when the modules are not powered or switched off. SARA-G350 modules do not provide the 32K_OUT output, as there is no EXT32K input to feed on the modules: the pin 24 constitute the GPIO3 on these modules. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 30 of 161 SARA-G3 series - System Integration Manual 1.7 Antenna interface 1.7.1 Antenna RF interface (ANT) The ANT pin of SARA-G3 modules represents the RF input/output for transmission and reception of the GSM/GPRS RF signal. The ANT pin has a nominal characteristic impedance of 50 and must be connected to the antenna through a 50 transmission line to allow proper RF transmission and reception in operating bands. 1.7.1.1 Antenna RF interface requirements Table 8Table 8 summarizes the requirements for the antenna RF interface (ANT). Refer to section 2.3.1 for suggestions to properly design an antenna circuit compliant to these requirements. The antenna circuit affects the RF compliance of the device integrating SARA-G3 series module with applicable required certification schemes. Compliance is guaranteed if the antenna RF interface (ANT) requirements summarized in Table 8Table 8 are fulfilled. Item Requirements Remarks Impedance 50 Frequency Range SARA-G350, SARA-G310: 824..960 MHz (GSM 850, GSM 900) 1710..1990 MHz (GSM 1800, GSM 1900) SARA-G300: 880..960 MHz (GSM 900) 1710..1880 MHz (GSM 1800) The impedance of the antenna RF connection must match the 50 impedance of the ANT pin. The required frequency range of the antenna depends on the operating bands of the used SARA-G3 module and the used Mobile Network. V.S.W.R Return Loss < 2:1 recommended, < 3:1 acceptable S11 < -10 dB recommended, S11 < -6 dB acceptable The impedance of the antenna termination must match as much as possible the 50 impedance of the ANT pin over the operating frequency range. Input Power > 2 W peak The antenna termination must withstand the maximum peak of power transmitted by SARA-G3 modules during a GSM single-slot call. Gain See section 4.2.2 for gain limits Detection Application board with antenna detection circuit The antenna gain must not exceed the herein specified value to comply with FCC radiation exposure limits. If antenna detection is required by the custom application, proper antenna detection circuit must be implemented on the application board as described in section 2.3.2. If antenna detection is required by the custom application, the external antenna assembly must be provided with proper diagnostic circuit as described in section 2.3.2. nominal characteristic impedance Antenna assembly with built-in diagnostic circuit Table 8: Summary of antenna RF interface (ANT) requirements For the additional specific requirement for SARA-G350 ATEX modules integration in potentially explosive atmospheres applications, refer to section 2.13. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 31 of 161 SARA-G3 series - System Integration Manual 1.7.2 Antenna detection interface (ANT_DET) SARA-G300 and SARA-G310 modules do not support antenna detection interface (ANT_DET). The antenna detection is based on ADC measurement. The ANT_DET pin is an Analog to Digital Converter (ADC) provided to sense the antenna presence. The antenna detection function provided by ANT_DET pin is an optional feature that can be implemented if the application requires it. The antenna detection is forced by the +UANTR AT command. Refer to the u-blox AT Commands Manual [2] for more details on this feature. The ANT_DET pin generates a DC current (20 µA for 5.4 ms) and measures the resulting DC voltage, thus determining the resistance from the antenna connector provided on the application board to GND. So, the requirements to achieve antenna detection functionality are the following: an RF antenna assembly with a built-in resistor (diagnostic circuit) must be used an antenna detection circuit must be implemented on the application board Refer to section 2.3.2 for antenna detection circuit on application board and diagnostic circuit on antenna assembly design-in guidelines. 1.8 SIM interface 1.8.1 (U)SIM card interface SARA-G3 modules provide a high-speed SIM/ME interface, including automatic detection and configuration of the voltage required by the connected (U)SIM card or chip. Both 1.8 V and 3 V SIM types are supported: activation and deactivation with automatic voltage switch from 1.8 V to 3 V is implemented, according to ISO-IEC 7816-3 specifications. The VSIM supply output pin provides internal short circuit protection to limit start-up current and protect the device in short circuit situations. The SIM driver supports the PPS (Protocol and Parameter Selection) procedure for baud-rate selection, according to the values determined by the SIM Card. SIM Application Toolkit (R99) is supported only by SARA-G350 modules. 1.8.2 SIM card detection interface (SIM_DET) The SIM_DET pin is configured as an external interrupt to detect the SIM card mechanical / physical presence. The pin is configured as input with an internal active pull-down enabled, and it can sense SIM card presence only if properly connected to the mechanical switch of a SIM card holder as described in section 2.4: Low logic level at SIM_DET input pin is recognized as SIM card not present High logic level at SIM_DET input pin is recognized as SIM card present The SIM card detection function provided by SIM_DET pin is an optional feature that can be implemented / used or not according to the application requirements. For more details on SIM detection function refer to the u-blox AT Commands Manual [2], “simind” value of theparameter of the +CIND and +CMER commands. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 32 of 161 SARA-G3 series - System Integration Manual 1.9 Serial interfaces SARA-G3 series modules provide the following serial communication interfaces: UART interface: 9-wire unbalanced 1.8 V asynchronous serial interface available for AT commands interface, Packet-Switched / Circuit-Switched Data communication, FW upgrades by means of the FOAT feature Auxiliary UART interface: 3-wire unbalanced 1.8 V asynchronous serial interface available only for the FW upgrade by means of the u-blox EasyFlash tool and for the Trace log capture (debug purpose) DDC interface: I C compatible 1.8 V interface available only for the communication with u-blox positioning chips and modules 1.9.1 Asynchronous serial interface (UART) 1.9.1.1 UART features The UART interface is a 9-wire 1.8 V unbalanced asynchronous serial interface, and it is the only serial interface of the SARA-G3 modules available for an AT command interface and for Packet-Switched / Circuit-Switched Data communication. The module firmware can be upgraded over the UART interface by means of the Firmware upgrade over AT (FOAT) feature only: for more details refer to section 1.13 and Firmware update application note [22]. UART interface provides RS-232 functionality conforming to the ITU-T V.24 Recommendation (more details available in ITU Recommendation [9]), with CMOS compatible signal levels: 0 V for low data bit or ON state, and 1.8 V for high data bit or OFF state. For detailed electrical characteristics refer to SARA-G3 series Data Sheet [1]. SARA-G3 modules are designed to operate as a GSM/GPRS wireless modem, which represents the data circuit-terminating equipment (DCE) as described by the ITU-T V.24 Recommendation [9]. A customer application processor connected to the module through the UART interface represents the data terminal equipment (DTE). The signal names of the UART interface of the SARA-G3 modules conform to the ITU-T V.24 Recommendation [9]: e.g. TXD line represents the data transmitted by the DTE (application processor data output) and received by the DCE (module input). The UART interface is controlled and operated with: AT commands according to 3GPP TS 27.007 [10] AT commands according to 3GPP TS 27.005 [11] AT commands according to 3GPP TS 27.010 [12] u-blox AT commands For the complete list of supported AT commands and their syntax refer to the u-blox AT Commands Manual [2]. All flow control handshakes are supported by the UART interface and can be set by appropriate AT commands (see u-blox AT Commands Manual [2], &K, +IFC, \Q AT commands): hardware flow control (RTS/CTS), software flow control (XON/XOFF), or none flow control. Hardware flow control is enabled by default. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 33 of 161 SARA-G3 series - System Integration Manual The following baud rates can be configured by AT command: 2400 b/s 4800 b/s 9600 b/s 19200 b/s 38400 b/s 57600 b/s 115200 b/s, default value when the autobauding is disabled The following baud rates are available with autobauding only: 1200 b/s 230400 b/s Autobauding is enabled by default. The following frame formats can be configured by AT command: 8N1 (8 data bits, No parity, 1 stop bit), default frame configuration with fixed baud rate 8E1 (8 data bits, even parity, 1 stop bit) 8O1 (8 data bits, odd parity, 1 stop bit) 8N2 (8 data bits, No parity, 2 stop bits) 7E1 (7 data bits, even parity, 1 stop bit) 7O1 (7 data bits, odd parity, 1 stop bit) Automatic frame recognition is supported and enabled by default in conjunction with the auto-bauding. When auto-bauding is active, the auto-framing is enabled overruling the frame format setting. Figure 16Figure 16 describes the 8N1 frame format, which is the default configuration with fixed baud rate. Normal Transfer, 8N1 Start of 1-Byte transfer D0 D1 Possible Start of next transfer D2 D3 D4 D5 Start Bit (Always 0) D6 D7 Stop Bit (Always 1) tbit = 1/(Baudrate) Figure 16: Description of UART default frame format (8N1) with fixed baud rate UBX-13000995 - A1 Advanced InformationPreliminary System description Page 34 of 161 SARA-G3 series - System Integration Manual 1.9.1.2 UART AT interface configuration The UART interface is the only AT command interface on SARA-G3 series modules. UART is configured as described in Table 9Table 9 (for information about further settings, refer to the u-blox AT Commands Manual [2]). Interface AT Settings Comments UART interface AT interface: enabled AT+IPR=0 AT command interface is enabled by default on the UART physical interface Automatic baud rate detection enabled by default AT+ICF=0 AT&K3 Automatic frame format recognition enabled by default HW flow control enabled AT&S1 DSR line set ON in data mode55 and set OFF in command mode5 AT&D1 Upon an ON-to-OFF transition of DTR, the DCE enters online command mode55 and issues an OK result code Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise Multiplexing mode is disabled by default and it can be enabled by AT+CMUX command. The following virtual channels are defined for SARA-G350 modules: Channel 0: control channel Channel 1 – 5: AT commands / data connection Channel 6: GPS tunneling The following virtual channels are defined for SARA-G300 and SARA-G310 modules: Channel 0: control channel Channel 1 – 2: AT commands / data connection AT&C1 MUX protocol: disabled Table 9: Default UART AT interface configuration 1.9.1.3 UART signal behavior (AT commands interface case) At the module switch-on, before the UART interface initialization (as described in the power-on sequence reported in Figure 13Figure 13), each pin is first tri-stated and then is set to its relative internal reset state. At the end of the boot sequence, the UART interface is initialized, the module is by default in active-mode, and the UART interface is enabled. The configuration and the behavior of the UART signals after the boot sequence are described below. See section 1.4 for definition and description of module operating modes referred to in this section. RXD signal behavior The module data output line (RXD) is set by default to the OFF state (high level) at UART initialization. The module holds RXD in the OFF state until the module does not transmit some data. TXD signal behavior The module data input line (TXD) is set by default to the OFF state (high level) at UART initialization. The TXD line is then held by the module in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the TXD input. Refer to the u-blox AT Commands Manual [2] for the definition of the interface data mode, command mode and online command mode. See the pin description table in the SARA-G3 series Data Sheet [1]. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 35 of 161 Formatted: Font: (Asian) Chinese (PRC), Superscript Formatted: Font: (Asian) Chinese (PRC), Superscript SARA-G3 series - System Integration Manual CTS signal behavior The module hardware flow control output (CTS line) is set to the ON state (low level) at UART initialization. If the hardware flow control is enabled, the CTS line indicates when the UART interface is enabled (data can be sent and received). The module drives the CTS line to the ON state or to the OFF state when it is either able or not able to accept data from the DTE. Refer to section 1.9.1.4 for the complete description. For more details, refer to u-blox AT Commands Manual [2], AT&K, AT\Q, AT+IFC AT command. If the hardware flow control is not enabled, the CTS line is always held in the ON state after UART initialization. If hardware flow control is enabled, then when the CTS line is ON the UART is enabled and the module is in active-mode. If the CTS line is OFF it does not necessarily mean that the module is in idle-mode, but only that the UART is not enabled (the module could be forced to stay in active-mode for other activities, e.g. network related). When the power saving configuration is enabled and the hardware flow-control is not implemented in the DTE/DCE connection, data sent by the DTE can be lost: the first character sent when the module is in idlemode will not be a valid communication character (see section 1.9.1.4 for complete description). When the multiplexer protocol is active, the CTS line state is mapped to FCon / FCoff MUX command for flow control issues outside the power saving configuration while the physical CTS line is still used as a power state indicator. For more details, refer to Mux Implementation Application Note [20]. RTS signal behavior The hardware flow control input (RTS line) is set by default to the OFF state (high level) at UART initialization. The module then holds the RTS line in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the RTS input. If the HW flow control is enabled (for more details, refer to u-blox AT Commands Manual [2] AT&K, AT\Q, AT+IFC command descriptions) the module monitors the RTS line to detect permission from the DTE to send data to the DTE itself. If the RTS line is set to the OFF state, any on-going data transmission from the module is immediately interrupted or any subsequent transmission forbidden until the RTS line changes to the ON state. The DTE must still be able to accept a certain number of characters after the RTS line is set to the OFF state: the module guarantees the transmission interruption within two characters from RTS state change. If AT+UPSV=2 is set and HW flow control is disabled, the module monitors the RTS line to manage the power saving configuration: When an OFF-to-ON transition occurs on the RTS input line, the UART is enabled and the module is forced to active-mode; after ~20 ms from the transition the switch is completed and data can be received without loss. The module cannot enter idle-mode and the UART is keep enabled as long as the RTS input line is held in the ON state If the RTS input line is set to the OFF state by the DTE, the UART is disabled (held in low power mode) and the module automatically enters idle-mode whenever possible For more details, refer to section 1.9.1.4 and u-blox AT Commands Manual [2], AT+UPSV command. DSR signal behavior If AT&S0 is set, the DSR module output line is set by default to the ON state (low level) at UART initialization and is then always held in the ON state. If AT&S1 is set, the DSR module output line is set by default to the OFF state (high level) at UART initialization. The DSR line is then set to the OFF state when the module is in command mode or in online command mode and is set to the ON state when the module is in data mode (refer to the u-blox AT Commands Manual [2] for the definition of the interface data mode, command mode and online command mode). UBX-13000995 - A1 Advanced InformationPreliminary System description Page 36 of 161 SARA-G3 series - System Integration Manual DTR signal behavior The DTR module input line is set by default to the OFF state (high level) at UART initialization. The module then holds the DTR line in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the DTR input. Module behavior according to DTR status depends on the AT command configuration (see u-blox AT Commands Manual [2], &D AT command). DCD signal behavior If AT&C0 is set, the DCD module output line is set by default to the ON state (low level) at UART initialization and is then always held in the ON state. If AT&C1 is set, the DCD module output line is set by default to the OFF state (high level) at UART initialization. The module then sets the DCD line according to the carrier detect status: ON if the carrier is detected, OFF otherwise. For voice calls, DCD is set to the ON state when the call is established. For a data call there are the following scenarios (refer to the u-blox AT Commands Manual [2] for the definition of the interface data mode, command mode and online command mode): Packet Switched Data call: Before activating the PPP protocol (data mode) a dial-up application must provide the ATD*99*** # to the module: with this command the module switches from command mode to data mode and can accept PPP packets. The module sets the DCD line to the ON state, then answers with a CONNECT to confirm the ATD*99 command. The DCD ON is not related to the context activation but with the data mode Circuit Switched Data call: To establish a data call, the DTE can send the ATD command to the module which sets an outgoing data call to a remote modem (or another data module). Data can be transparent (non reliable) or non transparent (with the reliable RLP protocol). When the remote DCE accepts the data call, the module DCD line is set to ON and the CONNECT string is returned by the module. At this stage the DTE can send characters through the serial line to the data module which sends them through the network to the remote DCE attached to a remote DTE The DCD is set to ON during the execution of the +CMGS, +CMGW, +USOWR, +USODL AT commands requiring input data from the DTE: the DCD line is set to the ON state as soon as the switch to binary/text input mode is completed and the prompt is issued; DCD line is set to OFF as soon as the input mode is interrupted or completed (for more details refer to the u-blox AT Commands Manual [2]). The DCD line is kept in the ON state, even during the online command mode, to indicate that the data call is still established even if suspended, while if the module enters command mode, the DSR line is set to the OFF state. For more details refer to DSR signal behaviorDSR signal behavior description. For scenarios when the DCD line setting is requested for different reasons (e.g. SMS texting during online command mode), the DCD line changes to guarantee the correct behavior for all the scenarios. For instance, in case of SMS texting in online command mode, if the data call is released, the DCD line is kept to ON till the SMS command execution is completed (even if the data call release would request the DCD setting to OFF). UBX-13000995 - A1 Advanced InformationPreliminary System description Page 37 of 161 Formatted: Font: Bold SARA-G3 series - System Integration Manual RI signal behavior The RI module output line is set by default to the OFF state (high level) at UART initialization. Then, during an incoming call, the RI line is switched from the OFF state to the ON state with a 4:1 duty cycle and a 5 s period (ON for 1 s, OFF for 4 s, see Figure 17Figure 17), until the DTE attached to the module sends the ATA string and the module accepts the incoming data call. The RING string sent by the module (DCE) to the serial port at constant time intervals is not correlated with the switch of the RI line to the ON state. 1s RI OFF RI ON 10 15 time [s] Call incomes Figure 17: RI behavior during an incoming call The RI line can notify an SMS arrival. When the SMS arrives, the RI line switches from OFF to ON for 1 s (see Figure 18Figure 18), if the feature is enabled by the proper AT command (refer to the u-blox AT Commands Manual [2], AT+CNMI command). 1s RI OFF RI ON time [s] SMS arrives Figure 18: RI behavior at SMS arrival This behavior allows the DTE to stay in power saving mode until the DCE related event requests service. For SMS arrival, if several events coincidently occur or in quick succession each event independently triggers the RI line, although the line will not be deactivated between each event. As a result, the RI line may stay to ON for more than 1 s. If an incoming call is answered within less than 1 s (with ATA or if auto-answering is set to ATS0=1) than the RI line is set to OFF earlier. As a result: RI line monitoring cannot be used by the DTE to determine the number of received SMSes. For multiple events (incoming call plus SMS received), the RI line cannot be used to discriminate the two events, but the DTE must rely on the subsequent URCs and interrogate the DCE with the proper commands. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 38 of 161 SARA-G3 series - System Integration Manual 1.9.1.4 UART and power-saving The power saving configuration is controlled by the AT+UPSV command (for the complete description, refer to u-blox AT Commands Manual [2]). When power saving is enabled, the module automatically enters low power idle-mode whenever possible, and otherwise the active-mode is maintained by the module (see section 1.4 for definition and description of module operating modes referred to in this section). The AT+UPSV command configures both the module power saving and also the UART behavior in relation to the power saving. The conditions for the module entering idle-mode also depend on the UART power saving configuration. Three different power saving configurations can be set by the AT+UPSV command: AT+UPSV=0, power saving disabled: module forced on active-mode and UART interface enabled (default) AT+UPSV=1, power saving enabled: module cyclic active / idle-mode and UART enabled / disabled AT+UPSV=2, power saving enabled and controlled by the UART RTS input line The different power saving configurations that can be set by the +UPSV AT command are described in details in the following subsections. Table 10Table 10 summarizes the UART interface communication process in the different power saving configurations, in relation with HW flow control settings and RTS input line status. For more details on the +UPSV AT command description, refer to u-blox AT commands Manual [2]. AT+UPSV HW flow control RTS line Communication during idle-mode and wake up Enabled (AT&K3) Enabled (AT&K3) ON OFF Disabled (AT&K0) Disabled (AT&K0) ON OFF Data sent by the DTE is correctly received by the module. Data sent by the module is buffered by the module and will be correctly received by the DTE when it is ready to receive data (i.e. RTS line is ON). Data sent by the DTE is correctly received by the module. Data sent by the module is correctly received by the DTE if it is ready to receive data, otherwise data is lost. Enabled (AT&K3) ON Enabled (AT&K3) OFF Disabled (AT&K0) ON Disabled (AT&K0) OFF Enabled (AT&K3) Enabled (AT&K3) ON OFF Not Applicable: HW flow control cannot be enabled with AT+UPSV=2. Not Applicable: HW flow control cannot be enabled with AT+UPSV=2. Disabled (AT&K0) Disabled (AT&K0) ON OFF Data sent by the DTE is correctly received by the module. The first character sent by the DTE is lost, but it wakes up the UART (if disabled) and the module (if in idle-mode) after ~20 ms. Recognition of subsequent characters is guaranteed only after the complete wake-up of the UART and the module (i.e. after ~20 ms). Data sent by the DTE is buffered by the DTE and will be correctly received by the module when active-mode is entered. Data sent by the module is buffered by the module and will be correctly received by the DTE when it is ready to receive data (i.e. RTS line will be ON). The first character sent by the DTE is lost, but it wakes up the UART (if disabled) and the module (if in idle-mode) after ~20 ms. Recognition of subsequent characters is guaranteed only after the complete wake-up of the UART and the module (i.e. after ~20 ms). Data sent by the module is correctly received by the DTE if it is ready to receive data, otherwise data is lost. Table 10: UART and power-saving summary AT+UPSV=0: power saving disabled, fixed active-mode The module does not enter idle-mode and the UART interface is enabled (data can be sent and received): the CTS line is always held in the ON state after UART initialization. This is the default configuration. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 39 of 161 SARA-G3 series - System Integration Manual AT+UPSV=1: power saving enabled, cyclic idle/active-mode The module automatically enters idle-mode whenever possible and, if the module is registered with network, it periodically wakes up from idle-mode to active-mode for at least ~11 ms to monitor the paging channel of the current base station (paging block reception), according to the GSM discontinuous reception (DRX) specification. The idle-mode period depends on the time period between two paging receptions defined by the current base station (i.e. by the network): the paging reception period can vary from ~0.47 s (DRX = 2, i.e. 2 x 51 GSM frames) up to ~2.12 s (DRX = 9, i.e. 9 x 51 GSM frames) When the module wakes up to active-mode for the paging block receptions, the UART interface is enabled for at least ~11 ms concurrently to each paging reception and then, as data has not been received or sent over the UART, the interface is disabled until the next paging reception. During a call, the UART interface is kept enabled, regardless of the AT+UPSV setting. If the module is not registered with a network, the cyclic idle/active-mode configuration is present as well: the module automatically enters idle-mode whenever possible and periodically wakes up to active-mode to enable the UART for at least ~11 ms and then, as data has not been received or sent over the UART, the interface is disabled for a defined period (according to the latest DRX setting) and afterwards the UART is enabled again. When UART interface is disabled, data transmitted by the DTE is lost if hardware flow control is disabled. If hardware flow control is enabled, data is buffered by the DTE and will be correctly received by the module when UART interface is enabled again. When UART interface is enabled, data can be received. When a character is received, it forces the UART interface to stay enabled for a longer time and it forces the module to stay in the active-mode for a longer time. The module active-mode duration depends on: The time period for the paging block reception, which is set by the current base station: ~11 ms minimum The time period where the UART interface is enabled, when the module is not registered with a network: ~11 ms minimum of in absence of data reception by serial interface The time period from the last data received at the serial port during the active-mode: the module does not enter idle-mode until a timeout expires. The second parameter of the +UPSV AT command configures this timeout, from 40 GSM TDMA frames (i.e. 40 x 4.615 ms = ~184 ms) up to 65000 GSM TDMA frames (i.e. 65000 x 4.615 ms = 300 s). Default value is 2000 GSM frames (i.e. 2000 x 4.615 ms = ~9.2 s) The active-mode duration can be extended indefinitely since every subsequent character received during the active-mode, resets and restarts the timer. If HW flow control is enabled, the hardware flow-control output (CTS line) indicates when the UART interface is enabled (data can be sent and received) as illustrated in Figure 19Figure 19. Data input CTS OFF CTS ON time [s] 0.47- 2.10 s ~10 ms (min) ~9.2 s (default) UART disabled UART enabled UART enabled Figure 19: CTS behavior with power saving enabled (AT+UPSV=1) and HW flow control enabled: the CTS output line indicates when the UART interface of the module is enabled (CTS = ON = low level) or disabled (CTS = OFF = high level) UBX-13000995 - A1 Advanced InformationPreliminary System description Page 40 of 161 SARA-G3 series - System Integration Manual AT+UPSV=2: power saving enabled and controlled by the RTS line This configuration can only be enabled with the module HW flow control disabled (AT&K0). The UART interface is immediately disabled after the DTE sets the RTS line to OFF. Then, if a voice or data call is not enabled, the module automatically enters idle-mode whenever possible according to any other activity, and periodically wakes up from idle-mode to active-mode to monitor the paging channel of the current base station (paging block reception). Instead, the UART is disabled as long as the RTS line is set to OFF, also when the module is in active-mode, to reduce power consumption. The UART is enabled in the following cases: During a call, the UART interface is kept enabled, regardless of the RTS line setting If the module must transmit some data over the UART (e.g. URC), the interface is temporarily enabled even if the RTS line is set to OFF by the DTE If the module receives a data over the UART, it causes the system wake-up: this is the “wake up via data reception” feature described in the following subsection When the DTE sets the RTS line to OFF, the timeout to enter idle-mode from the last data received at the serial port during the active-mode is the one previously set with the AT+UPSV=1 configuration or it is the default value. If the RTS line is set to ON by the DTE the module is not allowed to enter idle-mode and the UART is kept enabled until the RTS line is set to OFF. When an OFF-to-ON transition occurs on the RTS input line, the UART is re-enabled and the module, if it was in idle-mode, switches from idle to active-mode after ~20 ms: this is the UART and module “wake up time”. Even if HW flow control is disabled, if the DTE sets the RTS line to OFF, the module sets the CTS line accordingly to its power saving configuration as illustrated in Figure 19Figure 19, like for the AT+UPSV=1 case with HW flow control enabled. Wake up via data reception If the DTE transmits data when the UART is disabled (when power saving is configured), it is lost (not correctly received by the module) in the following cases: +UPSV=1 with hardware flow control disabled +UPSV=2 with hardware flow control disabled and RTS line set to OFF When the module is in idle-mode, the TXD input line of the module is always configured to wake up the UART and the module via data reception: when a low-to-high transition occurs on the TXD input line, it causes the system wake-up. The UART is enabled and the module switches from idle-mode to active-mode within ~20 ms from the first data reception: this is the system “wake up time”. As a consequence, the first character sent by the DTE when UART is disabled (i.e. the wake up character) is not a valid communication character because it cannot be recognized, and the recognition of the subsequent characters is guaranteed only after the complete system wake-up (i.e. after ~20 ms). Figure 20Figure 20 and Figure 21Figure 21 show examples of common scenarios and timing constraints: AT+UPSV=2 power saving configuration is active and the timeout from last data received to idle-mode start is set to 2000 frames due to the timeout previously set by AT+UPSV=1,2000 as the default case Hardware flow control disabled on the DCE (as required to enable the AT+UPSV=2 configuration) and RTS line set to OFF by the DTE: in this case the CTS line is set by the module accordingly to its power saving configuration as illustrated in Figure 19Figure 19, like for the AT+UPSV=1 case with HW flow control enabled Figure 20Figure 20 shows the case where the DCE UART is disabled and only a wake-up is forced. In this scenario the only character sent by the DTE is the wake-up character; as a consequence, the DCE UART is UBX-13000995 - A1 Advanced InformationPreliminary System description Page 41 of 161 SARA-G3 series - System Integration Manual disabled when the timeout from last data received expires (2000 frames without data reception, as the default case). DCE UART is enabled for 2000 GSM frames (~9.2 s) CTS OFF CTS ON time TxD module input Wake up time: ~20 ms Wake up character Not recognized by DCE time Figure 20: Wake-up via data reception without further communication Figure 21Figure 21 shows the case where in addition to the wake-up character further (valid) characters are sent. The wake up character wakes-up the DCE UART. The other characters must be sent after the “wake up time” of ~20 ms. If this condition is satisfied, the DCE recognizes characters. The DCE is allowed to disable the UART and re-enters idle-mode after 2000 GSM frames from the latest data reception. DCE UART is enabled for 2000 GSM frames (~9.2s) after the last data received CTS OFF CTS ON time TxD module input Wake up time: ~20 ms Wake up character Not recognized by DCE Valid characters Recognized by DCE time Figure 21: Wake-up via data reception with further communication The “wake-up via data reception” feature cannot be disabled. In command mode , if autobauding is enabled and the DTE does not implement HW flow control, the DTE must always send a character to the module before the “AT” prefix set at the beginning of each command line: the first character is ignored if the module is in active-mode, or it represents the wake-up character if the module is in idle-mode. Refer to the u-blox AT Commands Manual [2] for the definition of the interface data mode, command mode and online command mode. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 42 of 161 SARA-G3 series - System Integration Manual 77 In command mode , if autobauding is disabled, the DTE must always send a dummy “AT” before each command line: the first character is not ignored if the module is in active-mode (i.e. the module replies “OK”), or it represents the wake up character if the module is in idle-mode (i.e. the module does not reply). No wake-up character or dummy “AT” is required from the DTE during a voice or data call since the module UART interface continues to be enabled and does not need to be woken-up. Furthermore in data 77 mode a dummy “AT” would affect the data communication. 1.9.1.5 Multiplexer protocol (3GPP 27.010) SARA-G3 modules have a software layer with MUX functionality, 3GPP TS 27.010 Multiplexer Protocol [12], available on the UART physical link. The auxiliary UART and the DDC (I C) serial interfaces do not support the multiplexer protocol. This is a data link protocol (layer 2 of OSI model) which uses HDLC-like framing and operates between the module (DCE) and the application processor (DTE) and allows a number of simultaneous sessions over the used physical link (UART or SPI): the user can concurrently use AT command interface on one MUX channel and Packet-Switched / Circuit-Switched Data communication on another multiplexer channel. Each session consists of a stream of bytes transferring various kinds of data such as SMS, CBS, PSD, GPS, AT commands in general. This permits, for example, SMS to be transferred to the DTE when a data connection is in progress. The following virtual channels are defined for SARA-G350 modules: Channel 0: control channel Channel 1 – 5: AT commands / data connection Channel 6: GPS tunneling The following virtual channels are defined for SARA-G300 and SARA-G310 modules: Channel 0: control channel Channel 1 – 2: AT commands / data connection For more details, refer to Mux implementation Application Note [20]. 1.9.2 Auxiliary asynchronous serial interface (UART AUX) The auxiliary UART interface is a 3-wire unbalanced 1.8 V asynchronous serial interface (only the RXD_AUX data output and TXD_AUX data input are provided), available for SARA-G3 modules FW upgrade by means of the u-blox EasyFlash tool and for Trace log capture (debug purpose). The AT commands interface is not available on the auxiliary UART interface. 1.9.3 DDC (I C) interface SARA-G300 and SARA-G310 modules do not support DDC (I C) interface. An I C bus compatible Display Data Channel (DDC) interface for communication with u-blox GPS/GNSS receivers is available on SDA and SCL pins of SARA-G350 modules. Only this interface provides the communication between the u-blox wireless module and u-blox positioning chips and modules. The AT commands interface is not available on the DDC (I C) interface. DDC (I C) slave-mode operation is not supported: the SARA-G350 wireless module can act as master only, and the connected u-blox GPS/GNSS receiver automatically acts as slave in the DDC (I C) communication. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 43 of 161 Formatted: Superscript Formatted: Superscript SARA-G3 series - System Integration Manual Two lines, serial data (SDA) and serial clock (SCL), carry information on the bus. SCL is used to synchronize data transfers, and SDA is the data line. To be compliant to the I C bus specifications, the module bus interface pads are open drain output and pull up resistors must be used conforming to the I C bus specifications [13]. u-blox has implemented special features in SARA-G350 wireless modules to ease the design effort required for the integration of a u-blox wireless module with a u blox GPS/GNSS receiver. Combining a u-blox wireless module with a u-blox GPS/GNSS receiver allows designers to have full access to the positioning receiver directly via the wireless module: it relays control messages to the GPS/GNSS receiver via a nd dedicated DDC (I C) interface. A 2 interface connected to the positioning receiver is not necessary: AT commands via the UART serial interface of the wireless module allows a fully control of the GPS/GNSS receiver from any host processor. SARA-G350 modules feature embedded GPS aiding that is a set of specific features developed by u-blox to enhance GPS/GNSS performance, decreasing Time To First Fix (TTFF), thus allowing to calculate the position in a shorter time with higher accuracy. SARA-G350 modules support these GPS aiding types: Local aiding AssistNow Online AssistNow Offline AssistNow Autonomous The embedded GPS aiding features can be used only if the DDC (I C) interface of the wireless module is connected to the u-blox GPS/GNSS receivers. SARA-G350 wireless modules provide additional custom functions over GPIO pins to improve the integration with u-blox positioning chips and modules. GPIO pins can handle: GPS/GNSS receiver power-on/off: “GPS supply enable” function provided by GPIO2 improves the positioning receiver power consumption. When the GPS/GNSS functionality is not required, the positioning receiver can be completely switched off by the wireless module that is controlled by the application processor with AT commands The wake up from idle-mode when the GPS/GNSS receiver is ready to send data: “GPS data ready” function provided by GPIO3 improves the wireless module power consumption. When power saving is enabled in the wireless module by the AT+UPSV command and the GPS/GNSS receiver does not send data by the DDC (I C) interface, the module automatically enters idle-mode whenever possible. With the “GPS data ready” function the GPS/GNSS receiver can indicate to the wireless module that it is ready to send data by the DDC (I C) interface: the positioning receiver can wake up the wireless module if it is in idle-mode, so the wireless module does not lose the data sent by the GPS/GNSS receiver even if power saving is enabled The RTC synchronization signal to the GPS/GNSS receiver: “GPS RTC sharing” function provided by GPIO4 improves GPS/GNSS receiver performance, decreasing the Time To First Fix (TTFF), and thus allowing to calculate the position in a shorter time with higher accuracy. When GPS local aiding is enabled, the wireless module automatically uploads data such as position, time, ephemeris, almanac, health and ionospheric parameter from the positioning receiver into its local memory, and restores this to the GPS/GNSS receiver at the next power up of the positioning receiver For more details regarding the handling of the DDC (I C) interface, the GPS aiding features and the GPS related functions over GPIOs, refer to section 1.11, to the u-blox AT Commands Manual [2] (AT+UGPS, AT+UGPRF, AT+UGPIOC AT commands) and the GPS Implementation Application Note [21]. “GPS data ready” and “GPS RTC sharing” functions are not supported by all u-blox GPS/GNSS receivers HW or ROM/FW versions. Refer to the GPS Implementation Application Note [21] or to the Hardware Integration Manual of the u-blox GPS/GNSS receivers for the supported features. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 44 of 161 SARA-G3 series - System Integration Manual As additional improvement for the GPS/GNSS receiver performance, the V_BCKP supply output of SARA-G350 modules can be connected to the V_BCKP backup supply input pin of u-blox positioning chips and modules to provide the supply for the GPS/GNSS real time clock and backup RAM when the VCC supply of the wireless module is within its operating range and the VCC supply of the GPS/GNSS receiver is disabled. This enables the u-blox positioning receiver to recover from a power breakdown with either a hot start or a warm start (depending on the duration of the GPS/GNSS receiver VCC outage) and to maintain the configuration settings saved in the backup RAM. 1.10 Audio interface SARA-G300 and SARA-G310 modules do not support audio interface. SARA-G350 modules provide one analog audio interface and one digital audio interface that can be selected and set by the dedicated AT command +USPM (refer to u-blox AT Commands Manual [2]): this command allows setting the audio path mode, composed by the uplink audio path and the downlink audio path. Each uplink path mode defines the physical input (i.e. the analog or the digital audio input) and the set of parameters to process the uplink audio signal (uplink gains, uplink digital filters, echo canceller parameters). For example the “Headset microphone” uplink path uses the differential analog audio input with the default parameters for the headset profile. Each downlink path mode defines the physical output (i.e. the analog or the digital audio output) and the set of parameters to process the downlink audio signal (downlink gains, downlink digital filters and sidetone). For example the “Mono headset” downlink path uses the differential analog audio output with the default parameters for the headset profile. The set of parameters to process the uplink or the downlink audio signal can be changed with dedicated AT commands for each uplink or downlink path and then stored in two profiles in the non volatile memory (refer to u-blox AT Commands Manual [2] for Audio parameters tuning commands). 1.10.1 Analog audio interface 1.10.1.1 Uplink path SARA-G350 pins related to the analog audio uplink path are: MIC_P / MIC_N: Differential analog audio signal inputs (positive/negative). These two pins are internally directly connected to the differential input of an integrated Low Noise Amplifier, without any internal series capacitor for DC blocking. The LNA output is internally connected to the digital processing system by an integrated sigma-delta analog-to-digital converter MIC_BIAS: Supply output for an external microphone. The pin is internally connected to the output of a low noise LDO linear regulator provided with proper internal bypass capacitor to guarantee stable operation of the linear regulator MIC_GND: Local ground for the external microphone. The pin is internally connected to ground as a sense line as the reference for the analog audio input The analog audio input is selected when the parameter in AT+USPM command is set to “Headset microphone”, “Handset microphone” or “Hands-free microphone”: the uplink analog path profiles use the same physical input but have different sets of audio parameters (for more details, refer to u-blox AT Commands Manual [2], AT+USPM, AT+UMGC, AT+UUBF, AT+UHFP commands). SARA-G3 series Data Sheet [1] provides the detailed electrical characteristics of the analog audio uplink path. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 45 of 161 SARA-G3 series - System Integration Manual 1.10.1.2 Downlink path SARA-G350 pins related to the analog audio downlink path are: SPK_P / SPK_N: Differential analog audio signal output (positive/negative). These two pins are directly connected internally to the differential output of a low power audio amplifier, for which the input is connected internally to the digital processing system by to an integrated digital-to-analog converter. The analog audio output is selected when the parameter in AT+USPM command is set to “Normal earpiece”, “Mono headset” or “Loudspeaker”: the downlink analog path profiles use the same physical output but have different sets of audio parameters (for more details, refer to the u-blox AT Commands Manual [2], AT+USPM, AT+USGC, AT+UDBF, AT+USTN commands). The differential analog audio output of SARA-G350 modules (SPK_P / SPK_N) is able to directly drive loads with resistance rating greater than 14 : it can be directly connected to a headset earpiece or handset earpiece but cannot directly drive a 8 or 4 loudspeaker for the hands-free mode. SARA-G3 series Data Sheet [1] provides the detailed electrical characteristics of the analog audio downlink path. Warning: excessive sound pressure from headphones can cause hearing loss. 1.10.1.3 Headset mode Headset mode is the default audio operating mode of the modules. The headset profile is configured when the uplink audio path is set to “Headset microphone” and the downlink audio path is set to “Mono headset” (refer to u-blox AT Commands Manual [2]: AT+USPM command: , parameters). 1.10.1.4 Handset mode The handset profile is configured when the uplink audio path is set to “Handset microphone” and the downlink audio path is set to “Normal earpiece” (refer to u-blox AT commands manual [2]: AT+USPM command: , parameters). 1.10.1.5 Hands-free mode The hands-free profile is configured when the uplink audio path is set to “Hands-free microphone” and the downlink audio path is set to “Loudspeaker” (refer to u-blox AT commands manual [2]: AT+USPM command: , parameters). Hands-free functionality is implemented using appropriate digital signal processing algorithms for voice-band handling (echo canceller and automatic gain control), managed via software (refer to u-blox AT commands manual [2], AT+UHFP command). UBX-13000995 - A1 Advanced InformationPreliminary System description Page 46 of 161 SARA-G3 series - System Integration Manual 1.10.2 Digital audio interface SARA-G350 modules provide one 4-wire I S digital audio interface (1.8 V) that acts as an I S master and can be used for digital audio communication with external digital audio devices that acts as I S slave. Related pins are: I2S_TXD data output I2S_RXD data input I2S_CLK clock output I2S_WA world alignment output The I S interface can be set to two modes, by the parameter of the AT+UI2S command: PCM mode Normal I S mode SARA-G350 modules do not support I S slave mode: module acts as master only. The sample rate is fixed at 8 kHz only: it is not possible to configure the sample rate of transmitted and received words of SARA-G350 modules. The and parameters of the AT+USPM command must be properly configured to select the I S digital audio interfaces paths (for more details, refer to u-blox AT Commands Manual [2]): must be properly set to select: the I S interface (using I2S_RXD module input) must be properly set to select: the I S interface (using I2S_TXD module output) Parameters of digital path can be configured and saved as the normal analog paths, using appropriate path parameter as described in the u-blox AT Commands Manual [2], +USGC, +UMGC, +USTN AT command. Analog gain parameters of microphone and speakers are not used when digital path is selected. The I S receive data input and the I S transmit data output signals are respectively connected in parallel to the analog microphone input and speaker output signals, so resources available for analog path can be shared: Digital filters and digital gains are available in both uplink and downlink direction. The AT commands allow to properly configure them Ringer tone and service tone are mixed on the TX path when active (downlink) The HF algorithm acts on I S path Refer to the u-blox AT Commands Manual [2]: AT+UI2S command for possible settings of I S interface. 1.10.2.1 I S interface – PCM mode Main features of the I S interface in PCM mode: I S runs in PCM – short alignment mode (configurable by AT commands) I S word alignment signal is configured to 8 kHz: this is the parameter I S word alignment toggles high for 1 or 2 CLK cycles of synchronization (configurable), then toggles low for 16 CLK cycles of sample width. Frame length can be 1 + 16 = 17 bits or 2 + 16 = 18 bits I S clock frequency depends on frame length and the 8 kHz sample rate. Can be 17 x 8 kHz or 18 x 8 kHz I S transmit and I S receive data are 16 bit words long with the same sampling rate as I S word alignment, mono. Data is in 2’s complement notation. MSB is transmitted first UBX-13000995 - A1 Advanced InformationPreliminary System description Page 47 of 161 SARA-G3 series - System Integration Manual When I S word alignment toggles high, the first synchronization bit is always low. Second synchronization bit (present only in case of 2 bit long I S word alignment configuration) is MSB of the transmitted word (MSB is transmitted twice in this case) I S transmit data changes on I S clock rising edge, I S receive data changes on I S clock falling edge 1.10.2.2 I S interface – Normal I S mode Normal I S supports: 16 bits word Mono interface Sample rate: 8 kHz Main features of I S interface in normal I S mode: I S runs in normal I S – long alignment mode (configurable by AT commands) I S word alignment signal always runs at 8 kHz sample rate and synchronizes 2 channels (timeslots on word alignment high, word alignment low) I S transmit data is composed of 16 bit words, dual mono (the words are written on both channels). Data are in 2’s complement notation. MSB is transmitted first. The bits are written on I S clock rising or falling edge (configurable) I S receive data is read as 16 bit words, mono (words are read only on the timeslot with WA high). Data is read in 2’s complement notation. MSB is read first. The bits are read on the I S clock edge opposite to I S transmit data writing edge (configurable) I S clock frequency is 16 bits x 2 channels x 8 kHz The modes are configurable through a specific AT command (refer to the related section in the u-blox AT Commands Manual [2], +UI2S AT command) and the following parameters can be set: MSB can be 1 bit delayed or non-delayed on I S word alignment edge I S transmit data can change on rising or falling edge of I S clock signal I S receive data are read on the opposite front of I S clock signal 1.10.3 Voice-band processing system 1.10.3.1 Audio processing system overview The voice-band processing on the SARA-G350 modules is implemented in the DSP core inside the baseband chipset. The analog audio front-end of the chipset is connected to the digital system through 16 bit ADC converters in the uplink path, and through 16 bit DAC converters in the downlink path. External digital audio devices can directly be interfaced to the DSP digital processing part via the I S digital interface. The analog amplifiers are skipped in this case. The voice-band processing system can be split up into three different blocks: Sample-based Voice-band Processing (single sample processed at 8 kHz, every 125 µs) Frame-based Voice-band Processing (frames of 160 samples are processed every 20 ms) MIDI synthesizer running at 47.6 kHz These three blocks are connected by buffers and sample rate converters (for 8 to 47.6 kHz conversion) UBX-13000995 - A1 Advanced InformationPreliminary System description Page 48 of 161 SARA-G3 series - System Integration Manual Sample Based Processing Frame Based Processing I2S_RXD I2Sx RX ADC Uplink Filter 1 Switch Uplink Analog Gain Uplink Filter 2 Uplink Digital Gain Sidetone Digital Gain Downlink Filter 2 Switch SPK Analog Gain I2Sx TX Tone Generator Downlink Filter 1 Scal_Rec Digital Gain Circular Buffer DAC SPK To Radio TX Hands-Free Gain_Out Digital Gain Voiceband Sample Buffer MIC AMR Player From Radio RX Speech Level MIDI Player I2S_TXD Figure 22: SARA-G350 modules voice-band processing system block diagram The sample-based voice-band processing main task is to transfer the voice-band samples from either analog audio front-end uplink path or I2Sx RX path to the Voice-band Sample Buffer and from the Voice-band Sample Buffer to the analog audio front-end downlink path and/or I2Sx TX path. While doing this the samples are scaled by digital gains and processed by digital filters both in the uplink and downlink direction and the sidetone is generated mixing scaled uplink samples to the downlink samples (refer to the u-blox AT Commands Manual [2], +UUBF, +UDBF, +UMGC, +USGC, +USTN commands). The frame-based voice-band processing implements the Hands-Free algorithm. This consists of the Echo Canceller, the Automatic Gain Control and the Noise Suppressor. Hands-Free algorithm acts on the uplink signal only. Algorithms are configurable with AT commands (refer to the u-blox AT Commands Manual [2], +UHFP command). The frame-based voice-band processing also implements an AMR player. The speech uplink path final block before radio transmission is the speech encoder. Symmetrically, on downlink path, the starting block is the speech decoder which extracts speech signal from the radio receiver. The circular buffer is a 3000 word buffer to store and mix the voice-band samples from Midi synthesizer. The buffer has a circular structure, so that when the write pointer reaches the end of the buffer, it is wrapped to the begin address of the buffer. Two different sample-based sample rate converters are used: an interpolator, required to convert the sample-based voice-band processing sampling rate of 8 kHz to the analog audio front-end output rate of 47.6 kHz; a decimator, required to convert the circular buffer sampling rate of 47.6 kHz to the I2Sx TX or the uplink path sample rate of 8 kHz. 1.10.3.2 Audio codecs The following speech codecs are supported by firmware on the DSP : GSM Half Rate (TCH/HS) GSM Full Rate (TCH/FS) GSM Enhanced Full Rate (TCH/EFR) 3GPP Adaptive Multi Rate (AMR) (TCH/AFS+TCH/AHS) In AMR Full Rate (AFS) the Active CODEC Set is selected from an overall set of 8 data rates: 12.2 – 10.2 – 7.95 – 7.40 – 6.70 – 5.90 – 5.15 – 4.75 kb/s In AMR Half Rate (AHS) the overall set comprises 6 different data rates: 7.95 – 7.40 – 6.70 – 5.90 – 5.15 – 4.75 kb/s UBX-13000995 - A1 Advanced InformationPreliminary System description Page 49 of 161 SARA-G3 series - System Integration Manual 1.11 General Purpose Input/Output (GPIO) SARA-G300 and SARA-G310 modules do not support GPIOs. SARA-G350 modules provide 4 pins (GPIO1-GPIO4) which can be configured as general purpose input or output, or can be configured to provide special functions via u-blox AT commands (for further details refer to the u-blox AT Commands Manual [2], +UGPIOC, +UGPIOR, +UGPIOW, +UGPS, +UGPRF). The following functions are available in the SARA-G350 modules: Network status indication: The GPIO1, or the GPIO2, GPIO3 and GPIO4 alternatively from their default settings, can be configured to indicate network status (i.e. no service, registered home network, registered visitor network, voice or data call enabled), setting the parameter of AT+UGPIOC command to 2. No GPIO pin is by default configured to provide the “Network status indication” function. The “Network status indication” mode can be provided only on one pin per time: it is not possible to simultaneously set the same mode on another pin. The pin configured to provide the “Network status indication” function is set as Continuous Output / Low, if no service (no network coverage or not registered) Cyclic Output / High for 100 ms, Output / Low for 2 s, if registered with the home network Cyclic Output / High for 100 ms, Output / Low for 100 ms, Output / High for 100 ms, Output / Low for 2 s, if registered with the visitor network (roaming) Continuous Output / High, if voice or data call enabled GSM Tx burst indication: GPIO1 pin can be configured by AT+UGPIOC to indicate when a GSM Tx burst/slot occurs, setting the parameter of AT+UGPIOC command to 9. No GPIO pin is by default configured to provide the “GSM Tx burst indication” function. The pin configured to provide the “GSM Tx burst indication” function is set as Output / High, since ~10 µs before the start of first Tx slot, until ~5 µs after the end of last Tx slot Output / Low, otherwise GPS supply enable: The GPIO2 is by default configured by AT+UGPIOC command to enable or disable the supply of the u-blox GPS/GNSS receiver connected to the wireless module. The GPIO1, GPIO3 or GPIO4 pins can be configured to provide the “GPS supply enable” function, alternatively to the default GPIO2 pin, setting the parameter of AT+UGPIOC command to 3. The “GPS supply enable” mode can be provided only on one pin per time: it is not possible to simultaneously set the same mode on another pin. The pin configured to provide the “GPS supply enable” function is set as Output / High, to switch on the u-blox GPS/GNSS receiver, if the parameter of AT+UGPS command is set to 1 Output / Low, to switch off the u-blox GPS/GNSS receiver, if the parameter of AT+UGPS command is set to 0 (default setting) UBX-13000995 - A1 Advanced InformationPreliminary System description Page 50 of 161 SARA-G3 series - System Integration Manual GPS data ready: Only the GPIO3 pin provides the “GPS data ready” function, to sense when a u-blox GPS/GNSS receiver connected to the wireless module is ready to send data via the DDC (I C) interface, setting the parameter of AT+UGPIOC command to 4. The pin configured to provide the “GPS data ready” function is set as Input, to sense the line status, waking up the wireless module from idle-mode when the u-blox GPS/GNSS receiver is ready to send data via the DDC (I C) interface; the parameter of AT+UGPS command must be set to 1 and the parameter of AT+UGPRF command to 16 Tri-state with an internal active pull-down enabled, otherwise (default setting) GPS RTC sharing: Only the GPIO4 pin provides the “GPS RTC sharing” function, to provide an RTC (Real Time Clock) synchronization signal to the u-blox GPS/GNSS receiver connected to the wireless module, setting the parameter of AT+UGPIOC command to 5. The pin configured to provide the “GPS RTC sharing” function is set as Output, to provide an RTC (Real Time Clock) synchronization signal to the u-blox GPS/GNSS receiver if the parameter of AT+UGPS command is set to 1 and parameter of AT+UGPRF command is set to 32 Output / Low, otherwise (default setting) General purpose input: All the GPIOs can be configured as input to sense high or low digital level through AT+UGPIOR command, setting the parameter of AT+UGPIOC command to 1. The “General purpose input” mode can be provided on more than one pin at a time: it is possible to simultaneously set the same mode on another pin (also on all the GPIOs). No GPIO pin is by default configured as “General purpose input”. The pin configured to provide the “General purpose input” function is set as Input, to sense high or low digital level by AT+UGPIOR command. General purpose output: All the GPIOs can be configured as output to set the high or the low digital level through AT+UGPIOW command, setting the parameter of +UGPIOC AT command to 0. The “General purpose output” mode can be provided on more than one pin per time: it is possible to simultaneously set the same mode on another pin (also on all the GPIOs). No GPIO pin is by default configured as “General purpose output”. The pin configured to provide the “General purpose output” function is set as Output / Low, if the parameter of AT+UGPIOW command is set to 0 Output / High, if the parameter of AT+UGPIOW command is set to 1 Pad disabled: All the GPIOs can be configured in tri-state with an internal active pull-down enabled, as a not used pin, setting the parameter of +UGPIOC AT command to 255. The “Pad disabled” mode can be provided on more than one pin per time: it is possible to simultaneously set the same mode on another pin (also on all the GPIOs). The pin configured to provide the “Pad disabled” function is set as Tri-state with an internal active pull-down enabled UBX-13000995 - A1 Advanced InformationPreliminary System description Page 51 of 161 SARA-G3 series - System Integration Manual Table 11Table 11 describes the configurations of all SARA-G350 GPIO pins. Pin Module Name Description Remarks 16 SARA-G350 GPIO1 GPIO By default, the pin is configured as Pad disabled. Can be alternatively configured by the AT+UGPIOC command as Output Input Network Status Indication GPS Supply Enable GSM Tx Burst Indication 23 SARA-G350 GPIO2 GPIO By default, the pin is configured to provide GPS Supply Enable function. Can be alternatively configured by the +UGPIOC command as Output Input Network Status Indication Pad disabled 24 SARA-G350 GPIO3 GPIO By default, the pin is configured to provide GPS Data Ready function. Can be alternatively configured by the +UGPIOC command as Output Input Network Status Indication GPS Supply Enable Pad disabled 25 SARA-G350 GPIO4 GPIO By default, the pin is configured to provide GPS RTC sharing function. Can be alternatively configured by the +UGPIOC command as Output Input Network Status Indication GPS Supply Enable Pad disabled Table 11: GPIO pins configurations 1.12 Reserved pins (RSVD) SARA-G3 modules have pins reserved for future use: they can all be left unconnected on the application board, except the RSVD pin number 33 that must be externally connected to ground. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 52 of 161 SARA-G3 series - System Integration Manual 1.13 System features 1.13.1 Network indication Not supported by SARA-G300 and SARA-G310 modules. The GPIO1, or the GPIO2, GPIO3 and GPIO4 alternatively from their default settings, can be configured to indicate network status (i.e. no service, registered home network, registered visitor network, voice or data call enabled), by means of the AT+UGPIOC command. For the detailed description, refer to section 1.11 and to u-blox AT Commands Manual [2], GPIO commands. 1.13.2 Antenna detection Not supported by SARA-G300 and SARA-G310 modules. ANT_DET pin of SARA-G350 modules is an Analog to Digital Converter (ADC) provided to sense the presence of an external antenna when optionally set by the +UANTR AT command. The external antenna assembly must be provided with a built-in resistor (diagnostic circuit) to be detected, and an antenna detection circuit must be implemented on the application board properly connecting the antenna detection input (ANT_DET) to the antenna RF interface (ANT). For more details regarding feature description and detection / diagnostic circuit design-in refer to sections 1.7.2 and 2.3.2, and to the u-blox AT Commands Manual [2]. 1.13.3 Jamming detection Not supported by SARA-G300 and SARA-G310 modules. In real network situations modules can experience various kind of out-of-coverage conditions: limited service conditions when roaming to networks not supporting the specific SIM, limited service in cells which are not suitable or barred due to operators’ choices, no cell condition when moving to poorly served or highly interfered areas. In the latter case, interference can be artificially injected in the environment by a noise generator covering a given spectrum, thus obscuring the operator’s carriers entitled to give access to the GSM service. The Jamming Detection Feature detects such “artificial” interference and reports the start and stop of such conditions to the client, which can react appropriately by e.g. switching off the radio transceiver to reduce power consumption and monitoring the environment at constant periods. The feature detects, at radio resource level, an anomalous source of interference and signals it to the client with an unsolicited indication when the detection is entered or released. The jamming condition occurs when: The module has lost synchronization with the serving cell and cannot select any other cell The band scan reveals at least n carriers with power level equal or higher than threshold On all such carriers, no synchronization is possible The client can configure the number of minimum disturbing carriers and the power level threshold by using the AT+UCD command [2]. The jamming condition is cleared when any of the above mentioned statements does not hold. The congestion (i.e. jamming) detection feature can be enabled and configured by the +UCD AT command (for more details refer to the u-blox AT Commands Manual [2]). UBX-13000995 - A1 Advanced InformationPreliminary System description Page 53 of 161 SARA-G3 series - System Integration Manual 1.13.4 TCP/IP and UDP/IP Not supported by SARA-G300 and SARA-G310 modules. Via the AT commands it is possible to access the TCP/IP and UDP/IP functionalities over the Packet Switched data connection. For more details about AT commands see the u-blox AT Commands Manual [2]. Using the embedded TCP/IP or UDP/IP stack, only 1 IP instance (address) is supported. The IP instance supports up to 7 sockets. Using an external TCP/IP stack (on the application processor), it is possible to have 3 IP instances (addresses). Direct Link mode for TCP and UDP sockets is supported. Sockets can be set in Direct Link mode to establish a transparent end-to-end communication with an already connected TCP or UDP socket via serial interface. In Direct Link mode, data sent to the serial interface from an external application processor is forwarded to the network and vice-versa. To avoid data loss while using Direct Link, enable HW flow control on the serial interface. 1.13.5 FTP Not supported by SARA-G300 and SARA-G310 modules. SARA-G350 modules support the File Transfer Protocol functionalities via AT commands. Files are read and stored in the local file system of the module. For more details about AT commands see the u-blox AT Commands Manual [2]. 1.13.6 HTTP Not supported by SARA-G300 and SARA-G310 modules. HTTP client is implemented in SARA-G350 modules: HEAD, GET, POST, DELETE and PUT operations are available. The file size to be uploaded / downloaded depends on the free space available in the local file system (FFS) at the moment of the operation. Up to 4 HTTP client contexts can simultaneously be used. For more details about AT commands see the u-blox AT Commands Manual [2]. 1.13.7 SMTP Not supported by SARA-G300 and SARA-G310 modules. SARA-G350 modules support SMTP client functionalities. It is possible to specify the common parameters (e.g. server data, authentication method, etc. can be specified), to send an email to a SMTP server. Emails ca n be sent with or without attachment. Attachments are store in the local file system of SARA-G350 modules. For more details about AT commands see the u-blox AT Commands Manual [2]. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 54 of 161 SARA-G3 series - System Integration Manual 1.13.8 Smart temperature management Wireless modules – independent of the specific model – always have a well-defined operating temperature range. This range should be respected to guarantee full device functionality and long life span. Nevertheless there are environmental conditions that can affect operating temperature, e.g. if the device is located near a heating/cooling source, if there is/is not air circulating, etc. The module itself can also influence the environmental conditions; such as when it is transmitting at full power. In this case its temperature increases very quickly and can raise the temperature nearby. The best solution is always to properly design the system where the module is integrated. Nevertheless an extra check/security mechanism embedded into the module is a good solution to prevent operation of the device outside of the specified range. 1.13.8.1 Smart Temperature Supervisor (STS) The Smart Temperature Supervisor is activated and configured by a dedicated AT+USTS command. Refer to u-blox AT Commands Manual [2] for more details. The wireless module measures the internal temperature (Ti) and its value is compared with predefined thresholds to identify the actual working temperature range. Temperature measurement is done inside the module: the measured value could be different from the environmental temperature (Ta). Valid temperature range Dangerous area Warning area t-2 Safe area t-1 Warning area t+1 Dangerous area t+2 Figure 23: Temperature range and limits The entire temperature range is divided into sub-regions by limits (see Figure 23Figure 23) named t-2, t-1, t+1 and t+2. Within the first limit, (t-1 < Ti < t+1), the wireless module is in the normal working range, the Safe Area In the Warning Area, (t-2 < Ti < t.1) or (t+1 < Ti < t+2), the wireless module is still inside the valid temperature range, but the measured temperature approaches the limit (upper or lower). The module sends a warning to the user (through the active AT communication interface), which can take, if possible, the necessary actions to return to a safer temperature range or simply ignore the indication. The module is still in a valid and good working condition Outside the valid temperature range, (Ti < t-2) or (Ti > t+2), the device is working outside the specified range and represents a dangerous working condition. This condition is indicated and the device shuts down to avoid damage For security reasons the shutdown is suspended in case an emergency call in progress. In this case the device switches off at call termination. The user can decide at anytime to enable/disable the Smart Temperature Supervisor feature. If the feature is disabled there is no embedded protection against disallowed temperature conditions. UBX-13000995 - A1 Advanced InformationPreliminary System description Page 55 of 161 SARA-G3 series - System Integration Manual Figure 24Figure 24 shows the flow diagram implemented in SARA-G3 series modules for the Smart Temperature Supervisor. No IF STS enabled Feature disabled: no action Yes Feature enabled (full logic or indication only) Read temperature Yes Temperature is within normal operating range No No further actions IF (t-1 5V? Linear LDO Regulator No, less than 5 V Yes, greater than 5 V Switching Step-Down Regulator Figure 26: VCC supply concept selection The switching step-down regulator is the typical choice when the available primary supply source has a nominal voltage much higher (e.g. greater than 5 V) than the SARA-G3 modules operating supply voltage. The use of switching step-down provides the best power efficiency for the overall application and minimizes current drawn from the main supply source. The use of an LDO linear regulator becomes convenient for a primary supply with a relatively low voltage (e.g. less than 5 V). In this case the typical 90% efficiency of the switching regulator diminishes the benefit of voltage step-down and no true advantage is gained in input current savings. On the opposite side, linear regulators are not recommended for high voltage step-down as they dissipate a considerable amount of energy in thermal power. If SARA-G3 modules are deployed in a mobile unit where no permanent primary supply source is available, then a battery will be required to provide VCC. A standard 3-cell Li-Ion or Li-Pol battery pack directly connected to VCC is the usual choice for battery-powered devices. During charging, batteries with Ni-MH chemistry typically reach a maximum voltage that is above the maximum rating for VCC, and should therefore be avoided. The use of a primary (not rechargeable) battery is uncommon, since the most cells available are seldom capable of delivering the burst peak current for a GSM call due to high internal resistance. Keep in mind that the use of batteries requires the implementation of a suitable charger circuit (not included in SARA-G3 modules). The charger circuit should be designed in order to prevent over-voltage on VCC beyond the upper limit of the absolute maximum rating. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 64 of 161 SARA-G3 series - System Integration Manual The usage of more than one DC supply at the same time should be carefully evaluated: depending on the supply source characteristics, different DC supply systems can result as mutually exclusive. The usage of a regulator or a battery not able to withstand the maximum peak current consumption specified in the SARA-G3 series Data Sheet [1] is generally not recommended. However, if the selected regulator or battery is not able to withstand the maximum peak current of the module, it must be able to withstand at least the maximum average current consumption value specified in the SARA-G3 series Data Sheet [1]. The additional energy required by the module during a GSM/GPRS Tx slot (when in the worst case the current consumption can rise up to 1.9 A, as described in section 1.5.1.2) can be provided by an appropriate bypass tank capacitor or supercapacitor with very large capacitance and very low ESR placed close to the module VCC pins. Depending on the actual capability of the selected regulator or battery, the required capacitance can be considerably larger than 1 mF and the required ESR can be in the range of few tens of mΩ. Carefully evaluate the implementation of this solution since aging and temperature conditions significantly affect the actual capacitor characteristics. The following sections highlight some design aspects for each of the supplies listed above providing application circuit design-in compliant with the module VCC requirements summarized in Table 6Table 6. For the additional specific guidelines for SARA-G350 ATEX modules integration in potentially explosive atmospheres applications, refer to section 2.13. 2.1.1.2 Guidelines for VCC supply circuit design using a switching regulator The use of a switching regulator is suggested when the difference from the available supply rail to the VCC value is high: switching regulators provide good efficiency transforming a 12 V or greater voltage supply to the typical 3.8 V value of the VCC supply. The characteristics of the switching regulator connected to VCC pins should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6Table 6: Power capability: the switching regulator with its output circuit must be capable of providing a voltage value to the VCC pins within the specified operating range and must be capable of delivering 1.9 A current pulses with 1/8 duty cycle to the VCC pins Low output ripple: the switching regulator together with its output circuit must be capable of providing a clean (low noise) VCC voltage profile High switching frequency: for best performance and for smaller applications select a switching frequency ≥ 600 kHz (since L-C output filter is typically smaller for high switching frequency). The use of a switching regulator with a variable switching frequency or with a switching frequency lower than 600 kHz must be carefully evaluated since this can produce noise in the VCC voltage profile and therefore negatively impact GSM modulation spectrum performance. An additional L-C low-pass filter between the switching regulator output to VCC supply pins can mitigate the ripple on VCC, but adds extra voltage drop due to resistive losses on series inductors PWM mode operation: it is preferable to select regulators with Pulse Width Modulation (PWM) mode. While in connected-mode Pulse Frequency Modulation (PFM) mode and PFM/PWM mode, transitions must be avoided to reduce the noise on the VCC voltage profile. Switching regulators that are able to switch between low ripple PWM mode and high efficiency burst or PFM mode can be used, provided the mode transition occurs when the module changes status from idle/active-mode to connected-mode (where current consumption increases to a value greater than 100 mA): it is permissible to use a regulator that switches from the PWM mode to the burst or PFM mode at an appropriate current threshold (e.g. 60 mA) Output voltage slope: the use of the soft start function provided by some voltage regulators should be carefully evaluated, since the VCC pins voltage must ramp from 2.5 V to 3.2 V within 4 ms to switch on the module that otherwise can be switched on by a low level on PWR_ON pin UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 65 of 161 SARA-G3 series - System Integration Manual Figure 27Figure 27 and the components listed in Table 13Table 13 show an example of a high reliability power supply circuit, where the module VCC is supplied by a step-down switching regulator capable of delivering 1.9 A current pulses with low output ripple and with fixed switching frequency in PWM mode operation greater than 1 MHz. 12V SARA-G3 series VIN 5 RUN R1 BOOST 2 9 VC 10 RT R2 C1 C2 C3 C4 7 PG R3 C5 VCC VCC 53 VCC 51 BD SW 52 C6 L1 D1 U1 R4 C7 C8 FB 8 SYNC GND R5 11 GND Figure 27: Suggested schematic design for the VCC voltage supply application circuit using a step-down regulator Reference Description Part Number - Manufacturer C1 C2 10 µF Capacitor Ceramic X7R 5750 15% 50 V 10 nF Capacitor Ceramic X7R 0402 10% 16 V C5750X7R1H106MB - TDK GRM155R71C103KA01 - Murata C3 680 pF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71H681KA01 - Murata C4 C5 22 pF Capacitor Ceramic C0G 0402 5% 25 V 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM1555C1H220JZ01 - Murata GRM155R71C103KA01 - Murata C6 C7 470 nF Capacitor Ceramic X7R 0603 10% 25 V 22 µF Capacitor Ceramic X5R 1210 10% 25 V GRM188R71E474KA12 - Murata GRM32ER61E226KE15 - Murata C8 D1 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 mΩ Schottky Diode 40 V 3 A T520D337M006ATE045 - KEMET MBRA340T3G - ON Semiconductor L1 10 µH Inductor 744066100 30% 3.6 A 744066100 - Wurth Electronics R1 R2 470 kΩ Resistor 0402 5% 0.1 W 15 kΩ Resistor 0402 5% 0.1 W 2322-705-87474-L - Yageo 2322-705-87153-L - Yageo R3 R4 22 kΩ Resistor 0402 5% 0.1 W 390 kΩ Resistor 0402 1% 0.063 W 2322-705-87223-L - Yageo RC0402FR-07390KL - Yageo R5 U1 100 kΩ Resistor 0402 5% 0.1 W Step-Down Regulator MSOP10 3.5 A 2.4 MHz 2322-705-70104-L - Yageo LT3972IMSE#PBF - Linear Technology Table 13: Suggested components for the VCC voltage supply application circuit using a step-down regulator UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 66 of 161 SARA-G3 series - System Integration Manual Figure 28Figure 28 and the components listed in Table 14Table 14 show an example of a low cost power supply circuit, where the VCC module supply is provided by a step-down switching regulator capable of delivering 1.9 A current pulses, transforming a 12 V supply input. 12V SARA-G3 series VCC 6 FSW C6 R5 U1 2 SYNC R1 R3 C3 FB 5 COMP 4 52 L1 D1 C1 VCC VCC 53 VCC 51 OUT 1 3 INH C4 R4 C2 R2 GND GND C5 Figure 28: Suggested low cost solution for the VCC voltage supply application circuit using step-down regulator Reference Description Part Number - Manufacturer C1 22 µF Capacitor Ceramic X5R 1210 10% 25 V GRM32ER61E226KE15 – Murata C2 100 µF Capacitor Tantalum B_SIZE 20% 6.3V 15m T520B107M006ATE015 – Kemet C3 5.6 nF Capacitor Ceramic X7R 0402 10% 50 V GRM155R71H562KA88 – Murata C4 C5 6.8 nF Capacitor Ceramic X7R 0402 10% 50 V 56 pF Capacitor Ceramic C0G 0402 5% 50 V GRM155R71H682KA88 – Murata GRM1555C1H560JA01 – Murata C6 D1 220 nF Capacitor Ceramic X7R 0603 10% 25 V Schottky Diode 25V 2 A GRM188R71E224KA88 – Murata STPS2L25 – STMicroelectronics L1 5.2 µH Inductor 30% 5.28A 22 m MSS1038-522NL – Coilcraft R1 4.7 k Resistor 0402 1% 0.063 W RC0402FR-074K7L – Yageo R2 910 Resistor 0402 1% 0.063 W RC0402FR-07910RL – Yageo R3 82 R4 8.2 k Resistor 0402 5% 0.063 W RC0402JR-078K2L – Yageo R5 39 k Resistor 0402 5% 0.063 W RC0402JR-0739KL – Yageo U1 Step-Down Regulator 8-VFQFPN 3 A 1 MHz Resistor 0402 5% 0.063 W RC0402JR-0782RL – Yageo L5987TR – ST Microelectronics Table 14: Suggested components for low cost solution VCC voltage supply application circuit using a step-down regulator 2.1.1.3 Guidelines for VCC supply circuit design using a Low Drop-Out (LDO) linear regulator The use of a linear regulator is suggested when the difference from the available supply rail and the VCC value is low: linear regulators provide high efficiency when transforming a 5 V supply to a voltage value within the module VCC normal operating range. The characteristics of the LDO linear regulator connected to the VCC pins should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6Table 6: Power capabilities: the LDO linear regulator with its output circuit must be capable of providing a proper voltage value to the VCC pins and of delivering 1.9 A current pulses with 1/8 duty cycle Power dissipation: the power handling capability of the LDO linear regulator must be checked to limit its junction temperature to the maximum rated operating range (i.e. check the voltage drop from the max input voltage to the min output voltage to evaluate the power dissipation of the regulator) Output voltage slope: the use of the soft start function provided by some voltage regulator should be carefully evaluated, since the VCC pins voltage must ramp from 2.5 V to 3.2 V within 4 ms to switch-on the module that otherwise can be switched on by a low level on PWR_ON pin UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 67 of 161 SARA-G3 series - System Integration Manual Figure 29Figure 29 and the components listed in Table 15Table 15 show an example of a power supply circuit, where the VCC module supply is provided by an LDO linear regulator capable of delivering 1.9 A current pulses, with proper power handling capability. It is recommended to configure the LDO linear regulator to generate a voltage supply value slightly below the maximum limit of the module VCC normal operating range (e.g. ~4.1 V as in the circuit described in Figure 29Figure 29 and Table 15Table 15). This reduces the power on the linear regulator and improves the thermal design of the supply circuit. SARA-G3 series 5V IN OUT 51 VCC 52 VCC 53 VCC U1 C1 R1 R2 SHDN ADJ GND C2 GND R3 Figure 29: Suggested schematic design for the VCC voltage supply application circuit using an LDO linear regulator Reference Description Part Number - Manufacturer C1, C2 10 µF Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 - Murata R1 R2 47 kΩ Resistor 0402 5% 0.1 W 9.1 kΩ Resistor 0402 5% 0.1 W RC0402JR-0747KL - Yageo Phycomp RC0402JR-079K1L - Yageo Phycomp R3 3.9 kΩ Resistor 0402 5% 0.1 W RC0402JR-073K9L - Yageo Phycomp U1 LDO Linear Regulator ADJ 3.0 A LT1764AEQ#PBF - Linear Technology Table 15: Suggested components for VCC voltage supply application circuit using an LDO linear regulator 2.1.1.4 Guidelines for VCC supply circuit design using a rechargeable Li-Ion or Li-Pol battery Rechargeable Li-Ion or Li-Pol batteries connected to the VCC pins should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6Table 6: Maximum pulse and DC discharge current: the rechargeable Li-Ion battery with its output circuit must be capable of delivering 1.9 A current pulses with 1/8 duty-cycle to the VCC pins and must be capable of delivering a DC current greater than the module maximum average current consumption to VCC pins. The maximum pulse discharge current and the maximum DC discharge current are not always reported in battery data sheets, but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour DC series resistance: the rechargeable Li-Ion battery with its output circuit must be capable of avoiding a VCC voltage drop greater than 400 mV during transmit bursts 2.1.1.5 Guidelines for VCC supply circuit design using a primary (disposable) battery The characteristics of a primary (non-rechargeable) battery connected to VCC pins should meet the following prerequisites to comply with the module VCC requirements summarized in Table 6Table 6: Maximum pulse and DC discharge current: the non-rechargeable battery with its output circuit must be capable of delivering 1.9 A current pulses with 1/8 duty-cycle to the VCC pins and must be capable of delivering a DC current greater than the module maximum average current consumption at the VCC pins. The maximum pulse and the maximum DC discharge current is not always reported in battery data sheets, UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 68 of 161 SARA-G3 series - System Integration Manual but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour DC series resistance: the non-rechargeable battery with its output circuit must be capable of avoiding a VCC voltage drop greater than 400 mV during transmit bursts 2.1.1.6 Additional guidelines for VCC supply circuit design To reduce voltage drops, use a low impedance power source. The resistance of the power supply lines (connected to the VCC and GND pins of the module) on the application board and battery pack should also be considered and minimized: cabling and routing must be as short as possible to minimize power losses. Three pins are allocated for VCC supply. Another twenty pins are designated for GND connection. Even if all the VCC pins and all the GND pins are internally connected within the module, it is recommended to properly connect all of them to supply the module to minimize series resistance losses. To avoid voltage drop undershoot and overshoot at the start and end of a transmit burst during a GSM call (when current consumption on the VCC supply can rise up to 1.9 A in the worst case), place a bypass capacitor with large capacitance (more than 100 µF) and low ESR near the VCC pins, for example: 330 µF capacitance, 45 m ESR (e.g. KEMET T520D337M006ATE045, Tantalum Capacitor) The use of very large capacitors (i.e. greater then 1000 µF) on the VCC line should be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 4 ms to switch on the module that otherwise can be switched on by a low level on PWR_ON pin. To reduce voltage ripple and noise, especially if the application device integrates an internal antenna, place the following bypass capacitors near the VCC pins: 100 nF capacitor (e.g Murata GRM155R61C104K) to filter digital logic noise from clocks and data sources 10 nF capacitor (e.g. Murata GRM155R71C103K) to filter digital logic noise from clocks and data sources 56 pF capacitor with Self-Resonant Frequency in 800/900 MHz range (e.g. Murata GRM1555C1E560J) to filter transmission EMI in the GSM/EGSM bands 15 pF capacitor with Self-Resonant Frequency in 1800/1900 MHz range (e.g. Murata GRM1555C1E150J) to filter transmission EMI in the DCS/PCS bands Figure 30Figure 30 shows the complete configuration but the mounting of each single component depends on the application design: it is recommended to provide all the VCC bypass capacitors as described in Figure 30Figure 30 and Table 16Table 16 if the application device integrates an internal antenna. SARA-G3 series 3V8 VCC 51 VCC 52 VCC 53 C5 C4 C3 C2 C1 GND Figure 30: Suggested schematic and layout design for the VCC bypass capacitors to reduce ripple / noise on VCC voltage profile and to avoid undershoot / overshoot on VCC voltage drops UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 69 of 161 SARA-G3 series - System Integration Manual Reference Description Part Number - Manufacturer C1 C2 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 mΩ 100 nF Capacitor Ceramic X7R 0402 10% 16 V T520D337M006ATE045 - KEMET GRM155R71C104KA01 - Murata C3 C4 10 nF Capacitor Ceramic X7R 0402 10% 16 V 56 pF Capacitor Ceramic C0G 0402 5% 25 V GRM155R71C103KA01 - Murata GRM1555C1E560JA01 - Murata C5 15 pF Capacitor Ceramic C0G 0402 5% 25 V GRM1555C1E150JA01 - Murata Table 16: Suggested components to reduce ripple / noise on VCC and to avoid undershoot/ overshoot on VCC voltage drops ESD sensitivity rating of the VCC supply pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level can be required if the line is externally accessible on the application board, e.g. if accessible battery connector is directly connected to VCC pins. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible point. 2.1.1.7 Guidelines for external battery charging circuit SARA-G3 modules do not have an on-board charging circuit. Figure 31Figure 31 provides an example of a battery charger design, suitable for applications that are battery powered with a Li-Ion (or Li-Polymer) cell. In the application circuit, a rechargeable Li-Ion (or Li-Polymer) battery cell, that features proper pulse and DC discharge current capabilities and proper DC series resistance, is directly connected to the VCC supply input of SARA-G3 module. Battery charging is completely managed by the STMicroelectronics L6924U Battery Charger IC that, from a USB power source (5.0 V typ.), charges as a linear charger the battery, in three phases: Pre-charge constant current (active when the battery is deeply discharged): the battery is charged with a low current, set to 10% of the fast-charge current Fast-charge constant current: the battery is charged with the maximum current, configured by the value of an external resistor to a value suitable for USB power source (~500 mA) Constant voltage: when the battery voltage reaches the regulated output voltage (4.2 V), the L6924U starts to reduce the current until the charge termination is done. The charging process ends when the charging current reaches the value configured by an external resistor to ~15 mA or when the charging timer reaches the value configured by an external capacitor to ~9800 s Using a battery pack with an internal NTC resistor, the L6924U can monitor the battery temperature to protect the battery from operating under unsafe thermal conditions. Alternatively the L6924U, providing input voltage range up to 12 V, can charge from an AC wall adapter. When a current-limited adapter is used, it can operate in quasi-pulse mode, reducing power dissipation. Li-Ion/Li-Polymer Battery Charger IC SARA-G3 series 5V0 USB Supply VIN R1 R2 R3 VOUT VINSNS VOSNS MODE VREF ISEL Li-Ion/Li-Pol Battery Pack C3 IUSB IAC 51 VCC 52 VCC R4 53 VCC C4 TH θ IEND C5 C6 C7 C8 C9 TPRG SD C1 B1 GND GND C2 U1 D1 Figure 31: Li-Ion (or Li-Polymer) battery charging application circuit UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 70 of 161 SARA-G3 series - System Integration Manual Reference Description Part Number - Manufacturer B1 Various manufacturer C1, C4 Li-Ion (or Li-Polymer) battery pack with 470 NTC 1 µF Capacitor Ceramic X7R 0603 10% 16 V C2, C6 C3 10 nF Capacitor Ceramic X7R 0402 10% 16 V 1 nF Capacitor Ceramic X7R 0402 10% 50 V GRM155R71C103KA01 - Murata GRM155R71H102KA01 - Murata C5 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 m 100 nF Capacitor Ceramic X7R 0402 10% 16 V T520D337M006ATE045 - KEMET C7 C8 C9 56 pF Capacitor Ceramic C0G 0402 5% 25 V 15 pF Capacitor Ceramic C0G 0402 5% 25 V GRM1555C1E560JA01 - Murata GRM1555C1E150JA01 - Murata D1 Low Capacitance ESD Protection USB0002RP or USB0002DP - AVX R1, R2 24 k Resistor 0402 5% 0.1 W RC0402JR-0724KL - Yageo Phycomp R3 3.3 k Resistor 0402 5% 0.1 W RC0402JR-073K3L - Yageo Phycomp R4 1.0 k Resistor 0402 5% 0.1 W Single Cell Li-Ion (or Li-Polymer) Battery Charger IC for USB port and AC Adapter U1 GRM188R71C105KA12 - Murata GRM155R61A104KA01 - Murata RC0402JR-071K0L - Yageo Phycomp L6924U - STMicroelectronics Table 17: Suggested components for Li-Ion (or Li-Polymer) battery charging application circuit 2.1.1.8 Guidelines for VCC supply layout design Good connection of the module VCC pins with DC supply source is required for correct RF performance. Guidelines are summarized in the following list: All the available VCC pins must be connected to the DC source. VCC connection must be as wide as possible and as short as possible. Any series component with Equivalent Series Resistance (ESR) greater than few milliohms must be avoided. VCC connection must be routed through a PCB area separated from sensitive analog signals and sensitive functional units: it is good practice to interpose at least one layer of PCB ground between VCC track and other signal routing. Coupling between VCC and audio lines (especially microphone inputs) must be avoided, because the typical GSM burst has a periodic nature of approx. 217 Hz, which lies in the audible audio range. The tank bypass capacitor with low ESR for current spikes smoothing described in Figure 30Figure 30 and Table 16Table 16 should be placed close to the VCC pins. If the main DC source is a switching DC-DC converter, place the large capacitor close to the DC-DC output and minimize the VCC track length. Otherwise consider using separate capacitors for DC-DC converter and SARA-G3 module tank capacitor. The bypass capacitors in the pF range described in Figure 30Figure 30 and Table 16Table 16 should be placed as close as possible to the VCC pins. This is highly recommended if the application device integrates an internal antenna. Since VCC is directly connected to RF Power Amplifiers, voltage ripple at high frequency may result in unwanted spurious modulation of transmitter RF signal. This is more likely to happen with switching DC-DC converters, in which case it is better to select the highest operating frequency for the switcher and add a large L-C filter before connecting to the SARA-G3 series modules in the worst case. If VCC is protected by transient voltage suppressor to ensure that the voltage maximum ratings are not exceeded, place the protecting device along the path from the DC source toward the SARA-G3 module, preferably closer to the DC source (otherwise protection functionality may be compromised). 2.1.1.9 Guidelines for grounding layout design Good connection of the module GND pins with application board solid ground layer is required for correct RF performance. It significantly reduces EMC issues and provides a thermal heat sink for the module. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 71 of 161 SARA-G3 series - System Integration Manual Connect each GND pin with application board solid GND layer. It is strongly recommended that each GND pad surrounding VCC pins have one or more dedicated via down to the application board solid ground layer. The VCC supply current flows back to main DC source through GND as ground current: provide adequate return path with suitable uninterrupted ground plane to main DC source. If the application board is a multilayer PCB, then it is required to connect together each GND area with complete via stack down to main board ground layer. It is recommended to implement one layer of the application board as ground plane as wide as possible. Good grounding of GND pads also ensures thermal heat sink. This is critical during call connection, when the real network commands the module to transmit at maximum power: proper grounding helps prevent module overheating. 2.1.2 RTC supply (V_BCKP) 2.1.2.1 Guidelines for V_BCKP circuit design If RTC timing is required to run for a time interval of T [s] at 25 °C when VCC supply is removed, place a capacitor with a nominal capacitance of C [µF] at the V_BCKP pin. Choose the capacitor using the following formula: C [µF] = (Current_Consumption [µA] x T [s]) / Voltage_Drop [V] = 1.5 x T [s] For example, a 100 µF capacitor (such as the Murata GRM43SR60J107M) can be placed at V_BCKP to provide a long buffering time. This capacitor holds V_BCKP voltage within its valid range for around 50 s at 25 °C, after the VCC supply is removed. If a very long buffering time is required, a 70 mF super-capacitor (e.g. Seiko Instruments XH414H-IV01E) can be placed at V_BCKP, with a 4.7 k series resistor to hold the V_BCKP voltage within its valid range for approximately 10 hours at 25 °C, after the VCC supply is removed. The purpose of the series resistor is to limit the capacitor charging current due to the large capacitor specifications, and also to let a fast rise time of the voltage value at the V_BCKP pin after VCC supply has been provided. These capacitors allow the time reference to run during battery disconnection. (a) SARA-G3 series (b) V_BCKP C1 SARA-G3 series R2 (c) SARA-G3 series V_BCKP V_BCKP D3 B3 C2 (superCap) Figure 32: Real time clock supply (V_BCKP) application circuits: (a) using a 100 µF capacitor to let the RTC run for ~50 s after VCC removal; (b) using a 70 mF capacitor to let RTC run for ~10 hours after VCC removal; (c) using a non-rechargeable battery Reference Description Part Number - Manufacturer C1 100 µF Tantalum Capacitor GRM43SR60J107M - Murata R2 C2 4.7 kΩ Resistor 0402 5% 0.1 W 70 mF Capacitor RC0402JR-074K7L - Yageo Phycomp XH414H-IV01E - Seiko Instruments Table 18: Example of components for V_BCKP buffering UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 72 of 161 SARA-G3 series - System Integration Manual If longer buffering time is required to allow the RTC time reference to run during a disconnection of the VCC supply, then an external battery can be connected to V_BCKP pin. The battery should be able to provide a proper nominal voltage and must never exceed the maximum operating voltage for V_BCKP (specified in the Input characteristics of Supply/Power pins table in SARA-G3 series Data Sheet [1]). The connection of the battery to V_BCKP should be done with a suitable series resistor for a rechargeable battery, or with an appropriate series diode for a non-rechargeable battery. The purpose of the series resistor is to limit the battery charging current due to the battery specifications, and also to allow a fast rise time of the voltage value at the V_BCKP pin after the VCC supply has been provided. The purpose of the series diode is to avoid a current flow from the module V_BCKP pin to the non-rechargeable battery. If the RTC timing is not required when the VCC supply is removed, it is not needed to connect the V_BCKP pin to an external capacitor or battery. In this case the date and time are not updated when VCC is disconnected. If VCC is always supplied, then the internal regulator is supplied from the main supply and there is no need for an external component on V_BCKP. Combining a SARA-G3 wireless module with a u-blox GPS/GNSS positioning receiver, the positioning receiver VCC supply is controlled by the wireless module by means of the “GPS supply enable” function provided by the GPIO2 of the wireless module. In this case the V_BCKP supply output of the SARA-G3 wireless module can be connected to the V_BCKP backup supply input pin of the GPS/GNSS receiver to provide the supply for the positioning real time clock and backup RAM when the VCC supply of the wireless module is within its operating range and the VCC supply of the GPS/GNSS receiver is disabled. This enables the u-blox GPS/GNSS receiver to recover from a power breakdown with either a hot start or a warm start (depending on the duration of the positioning VCC outage) and to maintain the configuration settings saved in the backup RAM. Refer to section 2.5.32.5.3 for more details regarding the application circuit with a u-blox GPS/GNSS receiver. On SARA-G300 and SARA-G310 modules, the V_BCKP supply output can be used to supply an external 32 kHz oscillator which provides a 32 kHz signal to the EXT32K input pin as reference clock for the RTC timing, so that the modules can enter the low power idle-mode and can make available the RTC functions. The internal regulator for V_BCKP is optimized for low leakage current and very light loads. Do not apply loads which might exceed the limit for maximum available current from V_BCKP supply, as this can cause malfunctions in the module. SARA-G3 series Data Sheet [1] describes the detailed electrical characteristics. V_BCKP supply output pin provides internal short circuit protection to limit start-up current and protect the device in short circuit situations. No additional external short circuit protection is required. ESD sensitivity rating of the V_BCKP supply pin is 1 kV (Human Body Model according to JESD22-A114). Higher protection level can be required if the line is externally accessible on the application board, e.g. if an accessible back-up battery connector is directly connected to V_BCKP pin. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to the accessible point. 2.1.2.2 Guidelines for V_BCKP layout design RTC supply (V_BCKP) requires careful layout: avoid injecting noise on this voltage domain as it may affect the stability of the 32 kHz oscillator. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 73 of 161 SARA-G3 series - System Integration Manual 2.1.3 Interface supply (V_INT) 2.1.3.1 Guidelines for V_INT circuit design The V_INT digital interfaces 1.8 V supply output can be mainly used to: Pull-up DDC (I C) interface signals (see section 2.5.3 for more details) Formatted: English (U.S.) Pull-up SIM detection signal (see section 2.42.4 for more details) Supply voltage translators to connect digital interfaces of the module to a 3.0 V device (see section 2.5.1) Supply a 1.8 V u-blox 6 or subsequent GPS/GNSS receiver (see section 2.5.3 for more details) Indicate when the module is switched on Do not apply loads which might exceed the limit for maximum available current from V_INT supply, as this can cause malfunctions in internal circuitry supplies to the same domain. SARA-G3 series Data Sheet [1] describes the detailed electrical characteristics. V_INT can only be used as an output; do not connect any external regulator on V_INT. Since the V_INT supply is generated by an internal switching step-down regulator, the V_INT voltage ripple can range from 15 mVpp during active-mode or connected-mode (when the switching regulator operates in PWM mode), to 90 mVpp in idle-mode (when the switching regulator operates in PFM mode). It is not recommended to supply sensitive analog circuitry without adequate filtering for digital noise. V_INT supply output pin provides internal short circuit protection to limit start-up current and protect the device in short circuit situations. No additional external short circuit protection is required. ESD sensitivity rating of the V_INT supply pin is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the line is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible point. If the V_INT supply output is not required by the customer application, since DDC (I C) interface and SIM detection functions are not used and voltage translation of digital interfaces are not needed, the V_INT pin can be left unconnected to external components, but it is recommended providing direct access on the application board by means of accessible testpoint directly connected to the V_INT pin. 2.1.3.2 Guidelines for V_INT layout design V_INT digital interfaces supply output is generated by an integrated switching step-down converter, used internally to supply the digital interfaces. Because of this, it can be a source of noise: avoid coupling with sensitive signals. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 74 of 161 SARA-G3 series - System Integration Manual 2.2 System functions interfaces 2.2.1 Module power-on (PWR_ON) 2.2.1.1 Guidelines for PWR_ON circuit design Connecting the PWR_ON input to a push button that shorts the PWR_ON pin to ground, provide an external pull-up resistor (e.g. 100 kΩ) biased by the V_BCKP supply pin of the module, as described in Figure 33Figure 33 and Table 19Table 19. Connecting the PWR_ON input to a push button, the pin will be externally accessible on the application device: according to EMC/ESD requirements of the application, provide an additional ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin, close to accessible point. The PWR_ON pin has high input impedance and is weakly pulled to the high level on the module. Avoid keeping it floating in a noisy environment. To hold the high logic level stable, the PWR_ON pin must be connected to a pull-up resistor (e.g. 100 kΩ) biased by the V_BCKP supply pin of the module. ESD sensitivity rating of the PWR_ON pin is 1 kV (Human Body Model according to JESD22-A114). Higher protection level can be required if the line is externally accessible on the application board, e.g. if an accessible push button is directly connected to PWR_ON pin. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible point. When connecting the PWR_ON input to an external device (e.g. application processor), use an open drain output on the external device with an external pull-up resistor (e.g. 100 kΩ) biased by the V_BCKP supply pin of the module, as described in Figure 33Figure 33 and Table 19Table 19. A compatible push-pull output of an application processor can also be used: in this case the pull-up can be provided to pull the PWR_ON level high when the application processor is switched off. If the high-level voltage of the push-pull output pin of the application processor is greater than the maximum input voltage operating range of the V_BCKP pin (refer to SARA-G3 series Data Sheet [1]), the V_BCKP supply cannot be used to bias the pull-up resistor: the supply rail of the application processor or the module VCC supply could be used, but this increases the V_BCKP (RTC supply) current consumption when the module is in not-powered mode (VCC supply not present). Using a push-pull output of the external device, take care to fix the proper level in all the possible scenarios to avoid an inappropriate module switch-on. SARA-G3 series Application Processor V_BCKP Open Drain Output Rext Power-on push button TP 15 SARA-G3 series PWR_ON V_BCKP Rext TP 15 PWR_ON ESD Figure 33: PWR_ON application circuits using a push button and an open drain output of an application processor Reference Description Remarks Rext ESD 100 kΩ Resistor 0402 5% 0.1 W CT0402S14AHSG - EPCOS External pull-up resistor Varistor array for ESD protection Table 19: Example of pull-up resistor and ESD protection for the PWR_ON application circuit UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 75 of 161 SARA-G3 series - System Integration Manual It is recommended to provide direct access to the PWR_ON pin on the application board by means of accessible testpoint directly connected to the PWR_ON pin. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 76 of 161 SARA-G3 series - System Integration Manual 2.2.1.2 Guidelines for PWR_ON layout design The power-on circuit (PWR_ON) requires careful layout since it is the sensitive input available to switch on the SARA-G3 modules until a valid VCC supply is provided after that the module has been switched off by means of the AT+CPWROFF command: ensure that the voltage level is well defined during operation and no transient noise is coupled on this line, otherwise the module might detect a spurious power-on request. 2.2.2 Module reset (RESET_N) 2.2.2.1 Guidelines for RESET_N circuit design As described in Figure 15Figure 15, the module has an internal pull-up resistor on the reset input line: an external pull-up is not required on the application board. Connecting the RESET_N input to a push button that shorts the RESET_N pin to ground, the pin will be externally accessible on the application device: according to EMC/ESD requirements of the application, provide an additional ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin, close to accessible point, as described in Figure 34Figure 34 and Table 20Table 20. ESD sensitivity rating of the RESET_N pin is 1 kV (Human Body Model according to JESD22-A114). Higher protection level can be required if the line is externally accessible on the application board, e.g. if an accessible push button is directly connected to RESET_N pin. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible point. Connecting the RESET_N input to an external device (e.g. application processor), an open drain output can be directly connected without any external pull-up, as described in Figure 34Figure 34 and Table 20Table 20: the internal pull-up resistor provided by the module pulls the line to the high logic level when the RESET_N pin is not forced low by the application processor. A compatible push-pull output of an application processor can be used too. SARA-G3 series Reset push button TP Application Processor Open Drain Output 18 RESET_N SARA-G3 series TP 18 RESET_N ESD Figure 34: RESET_N application circuits using a push button and an open drain output of an application processor Reference Description Remarks ESD Varistor for ESD protection CT0402S14AHSG - EPCOS Table 20: Example of ESD protection component for the RESET_N application circuit If the external reset function is not required by the customer application, the RESET_N input pin can be left unconnected to external components, but it is recommended providing direct access on the application board by means of accessible testpoint directly connected to the RESET_N pin. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 77 of 161 SARA-G3 series - System Integration Manual 2.2.2.2 Guidelines for RESET_N layout design The reset circuit (RESET_N) requires careful layout due to the pin function: ensure that the voltage level is well defined during operation and no transient noise is coupled on this line, otherwise the module might detect a spurious reset request. It is recommended to keep the connection line to RESET_N as short as possible. 2.2.3 32 kHz signal (EXT32K and 32K_OUT) 2.2.3.1 Guidelines for EXT32K and 32K_OUT circuit design The application circuit of Figure 35Figure 35 describes how the 32K_OUT output pin of SARA-G300 / SARAG310 modules can be connected to the EXT32K input pin, providing the 32 kHz signal which constitutes the Real Time Clock (RTC) reference clock, so that the modules can enter the low power idle-mode, reaching low current consumption figures (refer to the section 1.5.1.3 and to the SARA-G3 series Data Sheet [1]), and can provide the RTC functions when the module is switched on. SARA-G300 SARA-G310 24 32K_OUT 31 EXT32K Figure 35: EXT32K application circuit using the 32 kHz signal provided by the 32K_OUT output The application circuit of Figure 36Figure 36 and Table 21Table 21 describe how an external oscillator can be connected to the EXT32K input pin of SARA-G300 / SARA-G310 modules, providing the external 32 kHz signal which constitutes the RTC reference clock, so that the modules can enter the very low power idle-mode, reaching very low current consumption figures (refer to the section 1.5.1.3 and to the SARA-G3 series Data Sheet [1]), and can provide the RTC functions when the RTC block is switched on since the V_BCKP voltage is within the valid range. SARA-G300 SARA-G310 V_BCKP 32 kHz Oscillator VCC C1 OE CLKOUT GND 31 EXT32K GND U1 Figure 36: EXT32K application circuit using an external 32 kHz oscillator Reference Description Remarks C1 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1 Low Power Clock Oscillator 32.768 kHz OV-7604-C7 - Micro Crystal or SG-3040LC - EPSON TOYOCOM Table 21: Example of components for the EXT32K application circuit UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 78 of 161 SARA-G3 series - System Integration Manual The two different solutions described in Figure 35Figure 35 and Figure 36Figure 36 are alternative and mutually exclusive: only one of the two proposed solutions must be implemented according to the required current consumption figures for the idle-mode (for the detailed characteristics refer to the SARA-G3 series Data Sheet [1]). As additional solution, alternative and mutually exclusive to the two described in Figure 35Figure 35 and Figure 36Figure 36, a proper 32 kHz signal can be provided to the EXT32K input by the used application processor, if capable. The EXT32K input and the 32K_OUT output are not available on SARA-G350 modules since the internal oscillator generates the 32 kHz RTC reference clock. ESD sensitivity rating of the EXT32K input pin and the 32K_OUT output pin is 1 kV (Human Body Model according to JESD22-A114). Higher protection level can be required if the line is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible point. If the customer application does not require the low power idle-mode and the RTC functions, the EXT32K input pin and the 32K_OUT output pin can be left not connected. 2.2.3.2 Guidelines for EXT32K and 32K_OUT layout design The EXT32K input pin and the 32K_OUT output pin require accurate layout design: avoid injecting noise on these pins as it may affect the stability of the RTC timing reference. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 79 of 161 SARA-G3 series - System Integration Manual 2.3 Antenna interface The ANT pin, provided by all SARA-G3 modules, represents the main RF input/output used to transmit and receive the GSM/GPRS RF signal: the main antenna must be connected to this pad. The ANT pin has a nominal characteristic impedance of 50 and must be connected to the antenna through a 50 transmission line to allow transmission and reception of radio frequency (RF) signals in the 2G and 3G operating bands. 2.3.1 Antenna RF interface (ANT) 2.3.1.1 General guidelines for antenna selection and design The GSM antenna is the most critical component to be evaluated: care must be taken about it at the start of the design development, when the physical dimensions of the application board are under analysis/decision, since the RF compliance of the device integrating SARA-G3 module with all the applicable required certification schemes depends from antenna radiating performance. GSM antennas are typically available as: Linear monopole / External antenna: External antenna usage basically does not imply physical restriction to the design of the PCB where the SARA-G3 series module is mounted The radiation performance mainly depends on the antenna: select the antenna with optimal radiating performance in the operating bands If antenna detection functionality is required, select an antenna assembly provided with a proper built-in diagnostic circuit with a resistor connected to ground: refer to guidelines in section 2.3.22.3.2 Select an RF cable with minimum insertion loss: additional insertion loss due to low quality or long cable reduces radiation performance Select a suitable 50 connector providing proper PCB-to-RF-cable transition: it is recommended to strictly follow the layout guidelines provided by the connector manufacturer Patch-like antenna / Integrated antenna: Internal integrated antenna implies physical restriction to the design of the PCB: the ground plane can be reduced down to a minimum size that must be similar to the quarter of the wavelength of the minimum frequency that has to be radiated. As numerical example: Frequency = 1 GHz Wavelength = 30 cm Minimum GND plane size = 7.5 cm The radiation performance depends on the whole PCB and antenna system design, including product mechanical design and usage: select the antenna with optimal radiating performance in the operating bands according to the mechanical specifications of the PCB and the whole product Select a complete custom antenna designed by an antenna manufacturer if the required ground plane dimensions are very small (e.g. less than 6.5 cm long and 4 cm wide): the antenna design process should begin at the start of the whole product design process Select an integrated antenna solution provided by an antenna manufacturer if the required ground plane dimensions are enough large enough according to the relativerelated integrated antenna solution specifications: the antenna selection and the definition of its placement in the product layout should begin at the start of the product design process It is highly recommended to strictly follow the detailed and specific guidelines provided by the antenna manufacturer regarding correct installation and deployment of the antenna system, including PCB layout and matching circuitry Further to the custom PCB and product restrictions, the antenna may require a tuning to comply with all the applicable required certification schemes.: iIt is recommended to consult ask the UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 80 of 161 Formatted: English (U.S.) SARA-G3 series - System Integration Manual antenna manufacturer for the design-in guidelines for the antenna matching relativerelated to the custom application In both cases, selecting an external or an internal antenna, observe these recommendations: Select an antenna providing optimal return loss (or V.S.W.R.) figure over all the operating frequencies Select an antenna providing optimal efficiency figure over all the operating frequencies Select an antenna providing appropriate gain figure (i.e. combined antenna directivity and efficiency figure) so that the electromagnetic field radiation intensity do not exceed the regulatory limits specified in some countries (e.g. by FCC in the United States, as reported in section 4.2.2) For the additional specific guidelines for SARA-G350 ATEX modules integration in potentially explosive atmospheres applications, refer to section 2.13. 2.3.1.2 Guidelines for antenna RF interface design Guidelines for ANT pin RF connection design Proper transition between the ANT pad and the application board PCB must be provided, implementing the following design-in guidelines for the layout of the application PCB close to the ANT pad: On a multi layer board, the whole layer stack below the RF connection should be free of digital lines Increase GND keep-out (i.e. clearance, a void area) around the ANT pad, on the top layer of the application PCB, to at least 250 µm up to adjacent pads metal definition and up to 400 µm on the area below the module, to reduce parasitic capacitance to ground, as described in the left picture in Figure 37Figure 37 Add GND keep-out (i.e. clearance, a void area) on the buried metal layer below the ANT pad if the top-layer to buried layer dielectric thickness is below 200 µm, to reduce parasitic capacitance to ground, as described in the right picture in Figure 37Figure 37 GND clearance on top layer around ANT pad GND clearance on buried layer below ANT pad Min. 250 µm GND Min. 400 µm Figure 37: GND keep-out area on the top layer around ANT pad and on the very close buried layer below ANT pad Guidelines for RF transmission line design The transmission line from the ANT pad up to antenna connector or up to the internal antenna pad must be designed so that the characteristic impedance is as close as possible to 50 . The transmission line can be designed as a micro strip (consists of a conducting strip separated from a ground plane by a dielectric material) or a strip line (consists of a flat strip of metal which is sandwiched between two UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 81 of 161 SARA-G3 series - System Integration Manual parallel ground planes within a dielectric material). The micro strip, implemented as a coplanar waveguide, is the most common configuration for printed circuit board. Figure 38Figure 38 and Figure 39Figure 39 provide two examples of proper 50 coplanar waveguide designs. The first transmission line can be implemented in case of 4-layer PCB stack-up herein described, the second transmission line can be implemented in case of 2-layer PCB stack-up herein described. 500 um 380 um 500 um L1 Copper 35 um FR-4 dielectric 270 um L2 Copper 35 um FR-4 dielectric 760 um L3 Copper 35 um FR-4 dielectric 270 um L4 Copper 35 um Figure 38: Example of 50 coplanar waveguide transmission line design for the described 4-layer board layup 400 um 1200 um 400 um L1 Copper 35 um FR-4 dielectric 1510 um L2 Copper 35 um Figure 39: Example of 50 coplanar waveguide transmission line design for the described 2-layer board layup If the two examples do not match the application PCB layup, the 50 characteristic impedance calculation can be made using the HFSS commercial finite element method solver for electromagnetic structures from Ansys Corporation, or using freeware tools like AppCAD from Agilent or TXLine from Applied Wave Research, taking care of the approximation formulas used by the tools for the impedance computation. To achieve a 50 characteristic impedance, the width of the transmission line must be chosen depending on: the thickness of the transmission line itself (e.g. 35 µm in the example of Figure 38Figure 38 and Figure 39Figure 39) the thickness of the dielectric material between the top layer (where the transmission line is routed) and the inner closer layer implementing the ground plane (e.g. 270 µm in Figure 38Figure 38, 1510 µm in Figure 39Figure 39) the dielectric constant of the dielectric material (e.g. dielectric constant of the FR-4 dielectric material in Figure 38Figure 38 and Figure 39Figure 39) the gap from the transmission line to the adjacent ground plane on the same layer of the transmission line (e.g. 500 µm in Figure 38Figure 38, 400 µm in Figure 39Figure 39) Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 82 of 161 SARA-G3 series - System Integration Manual If the distance between the transmission line and the adjacent GND area (on the same layer) does not exceed 5 times the track width of the micro strip, use the “Coplanar Waveguide” model for the 50 calculation. Additionally to the 50 impedance, the following guidelines are recommended for the transmission line design: Minimize the transmission line length: the insertion loss should be minimized as much as possible, in the order of a few tenths of a dB Add GND keep-out (i.e. clearance, a void area) on buried metal layers below any pad of component present on the RF transmission line, if top-layer to buried layer dielectric thickness is below 200 µm, to reduce parasitic capacitance to ground The transmission line width and spacing to GND must be uniform and routed as smoothly as possible: avoid abrupt changes of width and spacing to GND Add GND vias around transmission line, as described in Figure 40Figure 40 Ensure solid metal connection of the adjacent metal layer on the PCB stack-up to main ground layer, providing enough on the adjacent metal layer, as described in Figure 40Figure 40 Route RF transmission line far from any noise source (as switching supplies and digital lines) and from any sensitive circuit (as analog audio lines) Avoid stubs on the transmission line Avoid signal routing in parallel to transmission line or crossing the transmission line on buried metal layer Do not route microstrip line below discrete component or other mechanics placed on top layer An example of proper RF circuit design is reported in the Figure 40Figure 40. In this case, the antenna detection circuit is not implemented: the ANT pin is directly connected to an SMA connector by means of a proper 50 transmission line, designed with proper layout. If the antenna detection function is required by the application, follow the guidelines for circuit and layout implementation reported in section 2.3.2. SARA-G3 series SMA connector Figure 40: Suggested circuit and layout for antenna RF circuit on application board, if antenna detection is not required UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 83 of 161 SARA-G3 series - System Integration Manual Guidelines for RF termination design The RF termination must provide a characteristic impedance of 50 as well as the RF transmission line up to the RF termination itself, to match the characteristic impedance of the ANT pin of SARA-G3 modules. However, real antennas have no perfect 50 load on all the supported frequency bands. Therefore, to reduce as much as possible performance degradation due to antenna mismatch, the RF termination must provide optimal return loss (or V.S.W.R.) figure over all the operating frequency bands, as summarized in Table 8Table 8. If an external antenna is used, the antenna connector represents the RF termination on the PCB: Use a suitable 50 connector providing proper PCB-to-RF-cable transition Strictly follow the connector manufacturer’s recommended layout, for example: SMA Pin-Through-Hole connectors require GND keep-out (i.e. clearance, a void area) on all the layers around the central pin up to annular pads of the four GND posts, as shown in Figure 40Figure 40 Formatted: English (U.S.) U.FL surface mounted connectors require no conductive traces (i.e. clearance, a void area) in the area below the connector between the GND land pads Cut out the GND layer under RF connectors and close to buried vias, to remove stray capacitance and thus keep the RF line 50 : e.g. the active pad of U.FL connectors needs to have a GND keep-out (i.e. clearance, a void area) at least on first inner layer to reduce parasitic capacitance to ground If an integrated antenna is used, the RF termination is represented by the integrated antenna itself: Use an antenna designed by an antenna manufacturer, providing the best possible return loss (or V.S.W.R.) Provide a ground plane enough large enough according to the relativerelated integrated antenna requirements: the ground plane of the application PCB can be reduced down to a minimum size that must be similar to one quarter of wavelength of the minimum frequency that has to be radiated. As numerical example Frequency = 1 GHz Wavelength = 30 cm Minimum GND plane size = 7.5 cm It is highly recommended to strictly follow the detailed and specific guidelines provided by the antenna manufacturer regarding correct installation and deployment of the antenna system, including PCB layout and matching circuitry Further to the custom PCB and product restrictions, the antenna may require a tuning to comply with all the applicable required certification schemes. I: it is recommended to consult the antenna manufacturer for the design-in guidelines for the antenna matching relativerelated to the custom application Additionally, these recommendations regarding the antenna system must be followed: Do not include antenna within closed metal case Do not place the antenna in close vicinity to end users, since the emitted radiation in human tissue is limited by regulatory requirements Place the antenna far from sensitive analog systems or employ countermeasures to reduce electromagnetic compatibility issues Take care of interaction between co-located RF systems since the GSM transmitted power may interact or disturb the performance of companion systems The antenna shall provide optimal efficiency figure over all the operating frequencies The antenna shall provide appropriate gain figure (i.e. combined antenna directivity and efficiency figure) so that the electromagnetic field radiation intensity do does not exceed the regulatory limits specified in some countries (e.g. by FCC in the United States, as reported in section 4.2.2) Formatted: Hidden UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 84 of 161 SARA-G3 series - System Integration Manual 2.3.2 Antenna detection interface (ANT_DET) 2.3.2.1 Guidelines for ANT_DET circuit design Figure 41Figure 41 and Table 22Table 22 describe the recommended schematic and components for the antenna detection circuit to be provided on the application board for the diagnostic circuit that must be provided on the antenna assembly to achieve antenna detection functionality. Diagnostic Circuit SARA-G350 ANT 56 Z0 = 50 ohm Z0 = 50 ohm Z0 = 50 ohm C2 Radiating Element J1 C3 Antenna Cable L2 ANT_DET 62 R1 L1 C1 R2 D1 Application Board Antenna Assembly Figure 41: Suggested schematic for antenna detection circuit on application board and diagnostic circuit on antenna assembly Reference Description Part Number - Manufacturer C1 C2 27 pF Capacitor Ceramic C0G 0402 5% 50 V 33 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H270J - Murata GRM1555C1H330J - Murata D1 L1 Very Low Capacitance ESD Protection 68 nH Multilayer Inductor 0402 (SRF ~1 GHz) PESD0402-140 - Tyco Electronics LQG15HS68NJ02 - Murata R1 10 k RK73H1ETTP1002F - KOA Speer J1 SMA Connector 50 C3 22 pF Capacitor Ceramic C0G 0402 5% 25 V GRM1555C1H220J - Murata L2 R2 68 nH Multilayer Inductor 0402 (SRF ~1 GHz) LQG15HS68NJ02 - Murata Various Manufacturers 15 k Resistor 0402 1% 0.063 W Through Hole Jack Resistor for Diagnostic SMA6251A1-3GT50G-50 - Amphenol Table 22: Suggested components for antenna detection circuit on application board and diagnostic circuit on antenna assembly The antenna detection circuit and diagnostic circuit suggested in Figure 41Figure 41 and Table 22Table 22 are here explained: When antenna detection is forced by the +UANTR AT command, the ANT_DET pin generates a DC current measuring the resistance (R2) from the antenna connector (J1) provided on the application board to GND DC blocking capacitors are needed at the ANT pin (C2) and at the antenna radiating element (C3) to decouple the DC current generated by the ANT_DET pin Choke inductors with a Self Resonance Frequency (SRF) in the range of 1 GHz are needed in series at the ANT_DET pin (L1) and in series at the diagnostic resistor (L2), to avoid a reduction of the RF performance of the system, improving the RF isolation of the load resistor. Additional components (R1, C1 and D1 in Figure 41Figure 41) are needed at the ANT_DET pin as ESD protection The ANT pin must be connected to the antenna connector by means of a transmission line with nominal characteristics impedance as close as possible to 50 UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 85 of 161 Formatted: English (U.S.) SARA-G3 series - System Integration Manual The DC impedance at RF port for some antennas may be a DC open (e.g. linear monopole) or a DC short to reference GND (e.g. PIFA antenna). For those antennas, without the diagnostic circuit of Figure 41Figure 41, the measured DC resistance is always at the limits of the measurement range (respectively open or short), and there is no mean to distinguish between a defect on antenna path with similar characteristics (respectively: removal of linear antenna or RF cable shorted to GND for PIFA antenna). Furthermore, any other DC signal injected to the RF connection from ANT connector to radiating element will alter the measurement and produce invalid results for antenna detection. It is recommended to use an antenna with a built-in diagnostic resistor in the range from 5 k to 30 k to assure good antenna detection functionality and avoid a reduction of module RF performance. The choke inductor should exhibit a parallel Self Resonance Frequency (SRF) in the range of 1 GHz to improve the RF isolation of load resistor. For example: Consider a GSM antenna with built-in DC load resistor of 15 k . Using the +UANTR AT command, the module reports the resistance value evaluated from the antenna connector provided on the application board to GND: Reported values close to the used diagnostic resistor nominal value (i.e. values from 13 k 15 k diagnostic resistor is used) indicate that the antenna is properly connected to 17 k if a Values close to the measurement range maximum limit (approximately 50 k ) or an open-circuit “over range” report (see u-blox AT Commands Manual [2]) means that that the antenna is not connected or the RF cable is broken Reported values below the measurement range minimum limit (1 k ) highlights a short to GND at antenna or along the RF cable Measurement inside the valid measurement range and outside the expected range may indicate an improper connection, damaged antenna or wrong value of antenna load resistor for diagnostic Reported value could differ from the real resistance value of the diagnostic resistor mounted inside the antenna assembly due to antenna cable length, antenna cable capacity and the used measurement method If the antenna detection function is not required by the customer application, the ANT_DET pin can be left not connected and the ANT pin can be directly connected to the antenna connector by means of a 50 transmission line as described in Figure 40Figure 40. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 86 of 161 SARA-G3 series - System Integration Manual 2.3.2.1 Guidelines for ANT_DET layout design Figure 42Figure 42 describes the recommended layout for the antenna detection circuit to be provided on the application board to achieve antenna detection functionality, implementing the recommended schematic described in Figure 41Figure 41 and Table 22Table 22. SARA-G350 R1 D1 C1 C2 L1 J1 Figure 42: Suggested layout for antenna detection circuit on application board The antenna detection circuit layout suggested in Figure 42Figure 42 is here explained: The ANT pin is connected to the antenna connector by means of a 50 transmission line, implementing the design guidelines described in section 2.3.1 and the recommendations of the SMA connector manufacturer DC blocking capacitor at the ANT pin (C2) is placed in series to the 50 The ANT_DET pin is connected to the 50 transmission line transmission line by means of a sense line Choke inductor in series at the ANT_DET pin (L1) is placed so that one pad is on the 50 and the other pad represents the start of the sense line to the ANT_DET pin transmission line The additional components (R1, C1 and D1) on the ANT_DET line are placed as ESD protection UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 87 of 161 SARA-G3 series - System Integration Manual 2.4 2.4.1.1 SIM interface Guidelines for SIM circuit design Guidelines for SIM cards, SIM connectors and SIM chips selection The ISO/IEC 7816, the ETSI TS 102 221 and the ETSI TS 102 671 specifications define the physical, electrical and functional characteristics of Universal Integrated Circuit Cards (UICC) which contains the Subscriber Identification Module (SIM) integrated circuit that securely stores all the information needed to identify and authenticate subscribers over the GSM network. Removable UICC / SIM card contacts mapping is defined by ISO/IEC 7816 and ETSI TS 102 221as follows: Contact C1 = VCC (Supply) It must be connected to VSIM Contact C2 = RST (Reset) It must be connected to SIM_RST Contact C3 = CLK (Clock) It must be connected to SIM_CLK Contact C4 = AUX1 (Auxiliary contact) It must be left not connected Contact C5 = GND (Ground) It must be connected to GND Contact C6 = VPP (Programming supply) It must be connected to VSIM Contact C7 = I/O (Data input/output) It must be connected to SIM_IO Contact C8 = AUX2 (Auxiliary contact) It must be left not connected A removable SIM card can have 6 contacts (C1 = VCC, C2 = RST, C3 = CLK, C5 = GND, C6 = VPP, C7 = I/O) or 8 contacts, providing also the auxiliary contacts C4 = AUX1 and C8 = AUX2 for USB interfaces and other uses. Only 6 contacts are required and must be connected to the module SIM card interface as described above, since SARA-G3 modules do not support the additional auxiliary features (contacts C4 = AUX1 and C8 = AUX2). Removable SIM card are suitable for applications where the SIM changing is required during the product lifetime. A SIM card holder can have 6 or 8 positions if a mechanical card presence detector is not provided, or it can have 6+2 or 8+2 positions if two additional pins relativerelated to the normally-open mechanical switch integrated in the SIM connector for the mechanical card presence detection are provided: select a SIM connector providing 6+2 or 8+2 positions if the optional SIM detection feature is required by the custom application, otherwise a connector without integrated mechanical presence switch can be selected. Solderable UICC / SIM chip contacts mapping (M2M UICC Form Factor) is defined by ETSI TS 102 671 as follows: Package Pin 8 = UICC Contact C1 = VCC (Supply) It must be connected to VSIM Package Pin 7 = UICC Contact C2 = RST (Reset) It must be connected to SIM_RST Package Pin 6 = UICC Contact C3 = CLK (Clock) It must be connected to SIM_CLK Package Pin 5 = UICC Contact C4 = AUX1 (Auxiliary contact) It must be left not connected Package Pin 1 = UICC Contact C5 = GND (Ground) It must be connected to GND Package Pin 2 = UICC Contact C6 = VPP (Programming supply) It must be connected to VSIM Package Pin 3 = UICC Contact C7 = I/O (Data input/output) It must be connected to SIM_IO Package Pin 4 = UICC Contact C8 = AUX2 (Auxiliary contact) It must be left not connected A solderable SIM chip has 8 contacts and can provide also the auxiliary contacts C4 = AUX1 and C8 = AUX2 for USB interfaces and other uses, but only 6 contacts are required and must be connected to the module SIM card interface as described above, since SARA-G3 modules do not support the additional auxiliary features (contacts C4 = AUX1 and C8 = AUX2). Solderable SIM chips are suitable for M2M applications where it is not required to change the SIM once installed. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 88 of 161 SARA-G3 series - System Integration Manual Guidelines for single SIM card connection without detection A removable SIM card placed in a SIM card holder must be connected the SIM card interface of SARA-G3 modules as described in Figure 43Figure 43, where the optional SIM detection feature is not implemented (refer to the circuit described in Figure 45Figure 45 if the SIM detection feature is not required). Follow these guidelines connecting the module to a SIM connector without SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) and C6 (VPP) to the VSIM pin of the module Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module Connect the UICC / SIM contact C5 (GND) to ground Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM), close to the relative relevant pad of the SIM connector, to prevent digital noise Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), very close to each relative relevant pad of the SIM connector, to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holder Provide a very low capacitance (i.e. less than 10 pF) ESD protection (e.g. Tyco Electronics PESD0402-140) on each externally accessible SIM line, close to each relative relevant pad of the SIM connector: ESD sensitivity rating of the SIM interface pins is 1 kV (Human Body Model according to JESD22-A114), so that, according to the EMC/ESD requirements of the custom application, higher protection level can be required if the lines are externally accessible on the application device Limit capacitance and series resistance on each SIM signal (SIM_CLK, SIM_IO, SIM_RST) to match the requirements for the SIM interface (27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 µs is the maximum allowed rise time on the SIM_IO and SIM_RST lines) SARA-G3 series V_INT TP SIM CARD HOLDER SIM_DET 42 VPP (C6) VSIM 41 VCC (C1) SIM_IO 39 IO (C7) SIM_CLK 38 CLK (C3) SIM_RST 40 RST (C2) C1 C2 C3 C4 C5 GND (C5) D1 D2 D3 D4 C C C C 5 6 7 8 C C C C 1 2 3 4 SIM Card Bottom View (contacts side) J1 Figure 43: Application circuit for the connection to a single removable SIM card, with SIM detection not implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 47 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H470JA01 - Murata C5 D1, D2, D3, D4 100 nF Capacitor Ceramic X7R 0402 10% 16 V Very Low Capacitance ESD Protection GRM155R71C104KA01 - Murata PESD0402-140 - Tyco Electronics J1 SIM Card Holder 6 positions, without card presence switch Various Manufacturers, C707 10M006 136 2 - Amphenol Table 23: Example of components for the connection to a single removable SIM card, with SIM detection not implemented UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 89 of 161 SARA-G3 series - System Integration Manual Guidelines for single SIM chip connection A solderable SIM chip (M2M UICC Form Factor) must be connected the SIM card interface of SARA-G3 modules as described in Figure 44Figure 44, where the optional SIM detection feature is not implemented (refer to the circuit described in Figure 45Figure 45 if the SIM detection feature is not required). Follow these guidelines connecting the module to a solderable SIM chip without SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) and C6 (VPP) to the VSIM pin of the module Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module Connect the UICC / SIM contact C5 (GND) to ground Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM) close to the relativerelevant pad of the SIM chip, to prevent digital noise Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holder Limit capacitance and series resistance on each SIM signal (SIM_CLK, SIM_IO, SIM_RST) to match the requirements for the SIM interface (27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 µs is the maximum allowed rise time on the SIM_IO and SIM_RST lines) SARA-G3 series V_INT SIM_DET 42 TP SIM CHIP VSIM 41 SIM_IO 39 SIM_CLK 38 SIM_RST 40 C1 C2 C3 C4 C5 VPP (C6) VCC (C1) IO (C7) CLK (C3) RST (C2) GND (C5) 8 C1 C5 1 7 C2 C6 2 6 C3 C7 3 5 C4 C8 4 SIM Chip Bottom View (contacts side) U1 Figure 44: Application circuit for the connection to a single solderable SIM chip, with SIM detection not implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 47 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H470JA01 - Murata C5 U1 100 nF Capacitor Ceramic X7R 0402 10% 16 V SIM chip (M2M UICC Form Factor) GRM155R71C104KA01 - Murata Various Manufacturers Table 24: Example of components for the connection to a single solderable SIM chip, with SIM detection not implemented Guidelines for single SIM card connection with detection A removable SIM card placed in a SIM card holder must be connected to the SIM card interface of SARA-G3 modules as described in Figure 45Figure 45, where the optional SIM card detection feature is implemented. Follow these guidelines connecting the module to a SIM connector implementing SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) and C6 (VPP) to the VSIM pin of the module Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 90 of 161 SARA-G3 series - System Integration Manual Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module Connect the UICC / SIM contact C5 (GND) to ground Connect one pin of the mechanical switch integrated in the SIM connector (e.g. the SW2 pin as described in Figure 45Figure 45) to the SIM_DET input pin of the module Connect the other pin of the mechanical switch integrated in the SIM connector (e.g. the SW1 pin as described in Figure 45Figure 45) to the V_INT 1.8 V supply output of the module by means of a strong (e.g. 1 k ) pull-up resistor, as the R1 resistor in Figure 45Figure 45 Provide a weak (e.g. 470 k ) pull-down resistor at the SIM detection line, as the R2 resistor in Figure 45Figure 45 Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM), close to the relativerelevant pad of the SIM connector, to prevent digital noise Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), very close to each relativerelevant pad of the SIM connector, to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holder Provide a very low capacitance (i.e. less than 10 pF) ESD protection (e.g. Tyco Electronics PESD0402-140) on each externally accessible SIM line, close to each relativerelevant pad of the SIM connector: ESD sensitivity rating of the SIM interface pins is 1 kV (Human Body Model according to JESD22-A114), so that, according to the EMC/ESD requirements of the custom application, higher protection level can be required if the lines are externally accessible on the application device Limit capacitance and series resistance on each SIM signal (SIM_CLK, SIM_IO, SIM_RST) to match the requirements for the SIM interface (27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 µs is the maximum allowed rise time on the SIM_IO and SIM_RST lines) SIM CARD HOLDER SARA-G3 series V_INT TP R1 SIM_DET 42 R2 VSIM 41 SW1 SW2 VPP (C6) VCC (C1) SIM_IO 39 C C C C 5 6 7 8 IO (C7) SIM_CLK 38 CLK (C3) SIM_RST 40 RST (C2) C1 C2 C3 C4 C5 GND (C5) D1 D2 D3 D4 D5 D6 C C C C 1 2 3 4 SIM Card Bottom View (contacts side) J1 Figure 45: Application circuit for the connection to a single removable SIM card, with SIM detection implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 C5 47 pF Capacitor Ceramic C0G 0402 5% 50 V 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM1555C1H470JA01 - Murata GRM155R71C104KA01 - Murata D1, D2, D3, D4, D5, D6 Very Low Capacitance ESD Protection PESD0402-140 - Tyco Electronics R1 1k RC0402JR-071KL - Yageo Phycomp R2 470 k J1 SIM Card Holder 6 + 2 positions, with card presence switch Resistor 0402 5% 0.1 W Resistor 0402 5% 0.1 W RC0402JR-07470KL- Yageo Phycomp Various Manufacturers, CCM03-3013LFT R102 - C&K Components Table 25: Example of components for the connection to a single removable SIM card, with SIM detection implemented UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 91 of 161 SARA-G3 series - System Integration Manual Guidelines for dual SIM card connection with detection Two removable SIM card placed in two different SIM card holders must be connected to the SIM card interface of SARA-G3 modules as described in Figure 46Figure 46, providing also the SIM card detection feature. SARA-G3 modules do not support the usage of two SIM at the same time, but two SIM can be populated on the application board providing a proper switch to connect only the first or only the second SIM per time to the SIM card interface of the SARA-G3 modules as described in Figure 46Figure 46. SARA-G3 modules do not support SIM hot insertion / removal: the module is able to properly use a SIM only if the SIM / module physical connection is provided before the module boot and then held for normal operation. Switching from one SIM to another one can only be properly done within one of these two time periods: after module switch-off by the AT+CPWROFF and before module switch-on by PWR_ON after network deregistration by AT+COPS=2 and before module reset by AT+CFUN=16 or RESET_N In the application circuit represented in Figure 46Figure 46, the application processor must drive the SIM switch using its own GPIO before the module boot, to properly select the SIM that is used after the module boot. If the SIM detection feature is not required by the custom application, the relativerelated detection circuit described in Figure 46Figure 46 can be not implemented in the dual SIM connection circuit, leaving SIM_DET pin not connected. The dual SIM connection circuit described in Figure 46Figure 46 can be implemented for SIM chips as well, providing proper connection between SIM switch and SIM chip as described in Figure 44Figure 44. If it is required to switch between more than two SIM, a circuit similar to the one described in Figure 46Figure 46 can be implemented: for example, in case of four SIM circuit, using proper four-throw switches instead of the suggested double-throw switches. Follow these guidelines connecting the module to two SIM connectors implementing SIM presence detection: Connect the contacts C1 (VCC) and C6 (VPP) of the two UICC / SIM to the VSIM pin of the module by means of a proper low on resistance (i.e. few ohms) and low on capacitance (i.e. few pF) double-throw analog switch (e.g. Fairchild FSA2567) to ensure high-speed data transfer according to SIM requirements Connect the contact C7 (I/O) of the two UICC / SIM to the SIM_IO pin of the module by means of a proper low on resistance (i.e. few ohms) and low on capacitance (i.e. few pF) double-throw analog switch (e.g. Fairchild FSA2567) to ensure high-speed data transfer according to SIM requirements Connect the contact C3 (CLK) of the two UICC / SIM to the SIM_CLK pin of the module by means of a proper low on resistance (i.e. few ohms) and low on capacitance (i.e. few pF) double-throw analog switch (e.g. Fairchild FSA2567) to ensure high-speed data transfer according to SIM requirements Connect the contact C2 (RST) of the two UICC / SIM to the SIM_RST pin of the module by means of a proper low on resistance (i.e. few ohms) and low on capacitance (i.e. few pF) double-throw analog switch (e.g. Fairchild FSA2567) to ensure high-speed data transfer according to SIM requirements Connect the contact C5 (GND) of the two UICC / SIM to ground Connect one pin of the mechanical switch integrated in the two SIM connectors (e.g. the SW2 pins as described in Figure 46Figure 46) to the SIM_DET input pin of the module by means of a proper doublethrow digital switch (e.g. NXP 74LVC1G157) Connect the other pin of the mechanical switch integrated in the two SIM connectors (e.g. the SW1 pins as described in Figure 46Figure 46) to the V_INT 1.8 V supply output of the module by means of a strong (e.g. 1 k ) pull-up resistor, as the R1 and R3 resistors in Figure 46Figure 46 Provide a weak (e.g. 470 k ) pull-down resistor at the SIM detection line, between the double-throw digital switch and the relativerelated SIM connector as the R2 and R4 resistors in Figure 46Figure 46 Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM), close to the relativerelevant pad of the two SIM connectors, to prevent digital noise Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), very close to each relativerelevant pad of the two SIM connectors, to UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 92 of 161 SARA-G3 series - System Integration Manual prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holders Provide a very low capacitance (i.e. less than 10 pF) ESD protection (e.g. Tyco Electronics PESD0402-140) on each externally accessible SIM line, close to each relativerelevant pad of the two SIM connectors, according to the EMC/ESD requirements of the custom application Limit capacitance and series resistance on each SIM signal (SIM_CLK, SIM_IO, SIM_RST) to match the requirements for the SIM interface (27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 µs is the maximum allowed rise time on the SIM_IO and SIM_RST lines) FIRST SIM CARD HOLDER SARA-G3 series V_INT TP SPDT Digital Switch R1 C12 R2 VCC SIM_DET 42 I0 I1 VPP (C6) IO (C7) GND CLK (C3) U2 RST (C2) 3V8 4PDT Analog Switch VCC C1 C11 VSIM 1VSIM 2VSIM SIM_IO 39 DAT 1DAT 2DAT SIM_CLK 38 CLK 1CLK 2CLK RST 1RST 2RST SIM_RST 40 SW2 VCC (C1) VSIM 41 SW1 C2 C3 C4 GND (C5) C5 D1 D2 D3 D4 D5 D6 J1 SECOND SIM CARD HOLDER SEL R3 GND U1 R4 SW1 SW2 VPP (C6) VCC (C1) Application Processor IO (C7) CLK (C3) GPIO RST (C2) R5 C6 C7 C8 C9 C10 GND (C5) D7 D8 D9 D10 D11 D12 J2 Figure 46: Application circuit for the connection to two removable SIM cards, with SIM detection implemented Reference Description Part Number - Manufacturer C1 – C4, C6 – C9 33 pF Capacitor Ceramic C0G 0402 5% 25 V GRM1555C1H330JZ01 - Murata C5, C10 – C12 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C104KA01 - Murata D1 – D12 R1, R3 Very Low Capacitance ESD Protection 1 kΩ Resistor 0402 5% 0.1 W PESD0402-140 - Tyco Electronics RC0402JR-071KL - Yageo Phycomp R2, R4 R5 470 kΩ Resistor 0402 5% 0.1 W 47 kΩ Resistor 0402 5% 0.1 W RC0402JR-07470KL- Yageo Phycomp RC0402JR-0747KL- Yageo Phycomp J1, J2 SIM Card Holder, 6 + 2 p., with card presence switch CCM03-3013LFT R102 - C&K Components UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 93 of 161 SARA-G3 series - System Integration Manual Reference Description Part Number - Manufacturer U1 4PDT Analog Switch, with Low On-Capacitance and Low On-Resistance Single 2-Input Digital Multiplexer FSA2567 - Fairchild Semiconductor U2 74LVC1G157 - NXP Semiconductors Table 26: Example of components for the connection to two removable SIM cards, with SIM detection implemented UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 94 of 161 SARA-G3 series - System Integration Manual 2.4.1.2 Guidelines for SIM layout design The layout of the SIM card interface lines (VSIM, SIM_CLK, SIM_IO, SIM_RST) may be critical if the SIM card is placed far away from the SARA-G3 series modules or in close proximity to the RF antenna: these two cases should be avoided or at least mitigated as described below. In the first case, the long connection can cause the radiation of some harmonics of the digital data frequency as any other digital interface: keep the traces short and avoid coupling with RF line or sensitive analog inputs. In the second case, the same harmonics can be picked up and create self-interference that can reduce the sensitivity of GSM receiver channels whose carrier frequency is coincidental with harmonic frequencies: placing the RF bypass capacitors suggested in Figure 45Figure 45 near the SIM connector will mitigate the problem. In addition, since the SIM card is typically accessed by the end user, it can be subjected to ESD discharges: add adequate ESD protection as suggested in Figure 45Figure 45 to protect module SIM pins near the SIM connector. Limit capacitance and series resistance on each SIM signal to match the SIM specifications: the connections should always be kept as short as possible. Avoid coupling with any sensitive analog circuit, since the SIM signals can cause the radiation of some harmonics of the digital data frequency UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 95 of 161 SARA-G3 series - System Integration Manual 2.5 Serial interfaces 2.5.1 Asynchronous serial interface (UART) 2.5.1.1 Guidelines for UART circuit design Providing the full RS-232 functionality (using the complete V.24 link) If RS-232 compatible signal levels are needed, two different external voltage translators (e.g. Maxim MAX3237E and Texas Instruments SN74AVC8T245PW) can be used to provide full RS-232 (9 lines) functionality. The Texas Instruments chip provides the translation from 1.8 V to 3.3 V, while the Maxim chip provides the translation from 3.3 V to RS-232 compatible signal level. If a 1.8V application processor is used, for complete RS-232 functionality conforming to ITU Recommendation [9] in DTE/DCE serial communication, the complete UART interface of the module (DCE) must be connected to a 1.8 V application processor (DTE) as described in Figure 47Figure 47. Application Processor (1.8V DTE) SARA-G3 series (1.8V DCE) TxD 12 TXD RxD 13 RXD RTS 10 RTS CTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD GND GND Figure 47: UART interface application circuit with complete V.24 link in DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor is used, appropriate unidirectional voltage translators must be provided using the module V_INT output as 1.8 V supply, as described in Figure 48Figure 48. Application Processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC C1 VCCA DIR1 DIR3 SARA-G3 series (1.8V DCE) 1V8 TP VCCB V_INT C2 TxD A1 B1 12 TXD RxD A2 B2 13 RXD RTS RTS A3 B3 10 CTS A4 B4 11 CTS DIR2 DIR4 OE GND U1 Unidirectional Voltage Translator 3V0 C3 VCCA 1V8 VCCB C4 DIR1 DTR A1 B1 DTR DSR A2 B2 DSR RI A3 B3 RI DCD A4 B4 DCD GND DIR2 DIR3 DIR4 OE GND GND U2 Figure 48: UART interface application circuit with complete V.24 link in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2, C3, C4 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1, U2 Unidirectional Voltage Translator SN74AVC4T774 - Texas Instruments Table 27: Component for UART application circuit with complete V.24 link in DTE/DCE serial communication (3.0 V DTE) UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 96 of 161 SARA-G3 series - System Integration Manual Providing the TXD, RXD, RTS and CTS lines only (not using the complete V.24 link) If the functionality of the DSR, DCD, RI and DTR lines is not required in, or the lines are not available: Connect the module DTR input line to GND, since the module requires DTR active (low electrical level) Leave DSR, DCD and RI lines of the module unconnected and floating If RS-232 compatible signal levels are needed, the Maxim 13234E voltage level translator can be used. This chip translates voltage levels from 1.8 V (module side) to the RS-232 standard. If a 1.8 V Application Processor is used, the circuit should be implemented as described in Figure 49Figure 49. Application Processor (1.8V DTE) SARA-G3 series (1.8V DCE) TxD 12 TXD RxD 13 RXD RTS 10 RTS CTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD GND GND Figure 49: UART interface application circuit with partial V.24 link (5-wire) in the DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor is used, appropriate unidirectional voltage translators must be provided using the module V_INT output as 1.8 V supply, as described in Figure 50Figure 50. Application Processor (3.0V DTE) VCC Unidirectional Voltage Translator 3V0 C1 VCCA DIR1 DIR3 SARA-G3 series (1.8V DCE) 1V8 TP VCCB C2 V_INT TxD A1 B1 12 RxD A2 B2 13 RXD RTS A3 B3 10 RTS CTS A4 B4 11 CTS DTR DTR DSR DSR RI RI DCD DCD DIR2 DIR4 TXD OE GND U1 GND GND Figure 50: UART interface application circuit with partial V.24 link (5-wire) in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1 Unidirectional Voltage Translator SN74AVC4T774 - Texas Instruments Table 28: Component for UART application circuit with partial V.24 link (5-wire) in DTE/DCE serial communication (3.0 V DTE) If only TXD, RXD, RTS and CTS lines are provided, as implemented in Figure 49Figure 49 and in Figure 50Figure 50, the procedure to enable power saving depends on the HW flow-control status. If HW flow-control is enabled (AT&K3, that is the default setting) power saving will be activated by AT+UPSV=1. Through this configuration, when the module is in idle-mode, data transmitted by the DTE is buffered by the DTE and is correctly received by the module when active-mode is entered. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 97 of 161 SARA-G3 series - System Integration Manual If the HW flow-control is disabled (AT&K0), AT+UPSV=2 can enable the power saving. The module is in idlemode until a high-to-low (i.e. OFF-to-ON) transition on the RTS input line switches the module from idle-mode to active-mode in 20 ms. The module is forced into active-mode if the RTS input line is held in the ON state. Providing the TXD and RXD lines only (not using the complete V24 link) If the functionality of the CTS, RTS, DSR, DCD, RI and DTR lines is not required in the application, or the lines are not available, the circuit with a 1.8 V Application Processor should be implemented as described in Figure 51Figure 51: Connect the module RTS input line to GND or to the CTS output line of the module: since the module requires RTS active (low electrical level) if HW flow-control is enabled (AT&K3, that is the default setting), the pin can be connected using a 0 series resistor to GND or to the active-module CTS (low electrical level) when the module is in active-mode, the UART interface is enabled and the HW flow-control is enabled Connect the module DTR input line to GND, since the module requires DTR active (low electrical level) Leave DSR, DCD and RI lines of the module unconnected and floating Application Processor (1.8V DTE) SARA-G3 series (1.8V DCE) TxD 12 TXD RxD 13 RXD RTS 10 RTS CTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD GND GND Figure 51: UART interface application circuit with partial V.24 link (3-wire) in the DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor is used, appropriate unidirectional voltage translators must be provided using the module V_INT output as 1.8 V supply, as described in Figure 52Figure 52. Application Processor (3.0V DTE) VCC Unidirectional Voltage Translator 3V0 C1 VCCA SARA-G3 series (1.8V DCE) 1V8 TP VCCB C2 DIR1 V_INT TxD A1 B1 12 TXD RxD A2 B2 13 RXD DIR2 OE GND U1 RTS 11 RTS CTS 12 CTS DTR DTR DSR DSR RI RI DCD DCD GND GND Figure 52: UART interface application circuit with partial V.24 link (3-wire) in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1 Unidirectional Voltage Translator SN74AVC2T245 - Texas Instruments Table 29: Component for UART application circuit with partial V.24 link (3-wire) in DTE/DCE serial communication (3.0 V DTE) UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 98 of 161 SARA-G3 series - System Integration Manual If only TXD and RXD lines are provided, as described in Figure 51Figure 51 or in Figure 52Figure 52, and HW flow-control is disabled (AT&K0), the power saving must be enabled by AT+UPSV=1. In this way, the UART of the module is re-enabled 20 ms after a low-to-high transition on the TXD input line, and the recognition of the subsequent characters is guaranteed until the module is in active-mode. Data delivered by the DTE can be lost using this configuration and the following settings: HW flow-control enabled in the module (AT&K3, that is the default setting) Module power saving enabled by AT+UPSV=1 HW flow-control disabled in the DTE In this case the first character sent when the module is in idle-mode will be a wake-up character and will not be a valid communication character (refer to section 1.9.1.4 for the complete description). If power saving is enabled the application circuit with the TXD and RXD lines only is not recommended. During command mode the DTE must send to the module a wake-up character or a dummy “AT” before each command line (refer to section 1.9.1.4 for the complete description), but during data mode the wake-up character or the dummy “AT” would affect the data communication. Additional considerations Any external signal connected to the UART interface must be tri-stated or set low when the module is in power-down mode and during the module power-on sequence (at least until the activation of the V_INT supply output of the module), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the wireless module cannot be tri-stated or set low, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the twocircuit connections and set to high impedance during module power down mode and during the module power-on sequence. ESD sensitivity rating of UART interface pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible points. 2.5.1.2 Guidelines for UART layout design The UART serial interface requires the same consideration regarding electro-magnetic interference as any other digital interface. Keep the traces short and avoid coupling with RF line or sensitive analog inputs, since the signals can cause the radiation of some harmonics of the digital data frequency. 2.5.2 Auxiliary asynchronous serial interface (UART AUX) 2.5.2.1 Guidelines for UART AUX circuit design The auxiliary UART interface can be connected to an application processor if it can be set in pass-through mode so that the auxiliary UART interface can be accessed for SARA-G3 modules’ firmware upgrade by means of the u-blox EasyFlash tool and for Trace log capture (debug purpose). To directly enable PC (or similar) connection to the module for firmware upgrade using the u-blox EasyFlash tool and for debugging purposes, it is highly recommended to provide direct access on the application board to the TXD_AUX and RXD_AUX pins, by means of accessible testpoints directly connected to the pins of the module. Also provide access to the V_INT pin to make possible the voltage translation to the auxiliary UART interface voltage level, and to the PWR_ON or RESET_N pins, or enable the DC supply connected to the VCC pin to start the firmware upgrade using the u-blox EasyFlash tool. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 99 of 161 SARA-G3 series - System Integration Manual The circuit with a 1.8 V Application Processor should be implemented as described in Figure 51Figure 51. Application Processor (1.8V DTE) SARA-G3 series (1.8V DCE) TxD RxD 0 ohm TestPoint 0 ohm TestPoint 29 TXD_AUX 28 RXD_AUX GND GND Figure 53: UART AUX interface application circuit connecting a 1.8 V application processor If a 3.0 V Application Processor is used, appropriate unidirectional voltage translators must be provided using the module V_INT output as 1.8 V supply, as described in Figure 52Figure 52. Application Processor (3.0V DTE) VCC Unidirectional Voltage Translator 3V0 C1 VCCA TxD A1 B1 A2 B2 GND TP VCCB DIR2 C2 DIR1 RxD SARA-G3 series (1.8V DCE) 1V8 0 ohm TP 0 ohm TP V_INT 29 TXD_AUX 28 RXD_AUX OE GND GND U1 Figure 54: UART AUX interface application circuit connecting a 3.0 V application processor Reference Description Part Number - Manufacturer C1, C2 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1 Unidirectional Voltage Translator SN74AVC2T245 - Texas Instruments Table 30: Component for UART AUX interface application circuit connecting a 3.0 V application processor Refer to Firmware Update Application Note [22] for additional guidelines regarding the procedure for SARA-G3 modules’ firmware upgrade over the auxiliary UART interface using the u-blox EasyFlash tool. Any external signal connected to the auxiliary UART interface must be tri-stated or set low when the module is in power-down mode and during the module power-on sequence (at least until the activation of the V_INT supply output of the module), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the wireless module cannot be tri-stated or set low, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode and during the module power-on sequence. ESD sensitivity rating of auxiliary UART pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible points. 2.5.2.2 Guidelines for UART AUX layout design The auxiliary UART serial interface is not critical for the layout design since it is not used during normal operation of SARA-G3 modules. Ensure accessibility to the TXD_AUX and RXD_AUX pins providing test points on the application board. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 100 of 161 SARA-G3 series - System Integration Manual 2.5.3 DDC (I2C) interface 2.5.3.1 Guidelines for DDC (I C) circuit design The SDA and SCL lines must be connected to the DDC (I C) interface pins of the u-blox GPS/GNSS receiver (i.e. the SDA2 and SCL2 pins of the u-blox positioning receiver) on the application board to allow the communication between the wireless module and the u-blox GPS/GNSS receiver, enabled by the AT+UGPS command (for more details refer to u-blox AT Commands Manual [2]). To be compliant to the I C bus specifications, the module bus interface pads are open drain output and pull up resistors must be used conforming to the I C bus specifications [13]. Since the pull-up resistors are not mounted on the module, they must be mounted externally. Provide external pull-ups resistors (e.g. 4.7 k ) on SDA and SCL lines and connect them to the V_INT 1.8 V supply source, or another 1.8 V supply source enabled after V_INT (e.g., as the 1.8 V supply present in the application circuit of Figure 55Figure 55, controlled by the wireless module). The signal shape is defined by the values of the pull-up resistors and the bus capacitance. Long wires on the bus increase the capacitance. If the bus capacitance is increased, use pull-up resistors with nominal resistance value lower than 4.7 k , to match the I C bus specifications [13] regarding rise and fall times of the signals. Capacitance and series resistance must be limited on the bus to match the I C specifications (1.0 µs is the maximum allowed rise time on the SCL and SDA lines): route connections as short as possible. If the pins are not used as DDC bus interface, they can be left unconnected. The following special features over GPIOs can be optionally implemented on the application board to improve the integration of SARA-G350 wireless modules with a u blox GPS/GNSS receiver: The GPIO2, by default configured to provide the “GPS supply enable” function, must be connected to the active-high enable pin (or the active-low shutdown pin) of the voltage regulator that supplies the u-blox positioning receiver on the application board to enable or disable the supply of the u-blox GPS/GNSS receiver connected to the wireless module by the AT+UGPS command The GPIO3, by default configured to provide the “GPS data ready” function, must be connected to the data ready output of the u-blox positioning receiver (i.e. the pin TXD1 of the u-blox GPS/GNSS receiver) on the application board, to sense when the u-blox positioning receiver connected to the wireless module is ready to send data by the DDC (I C) interface The GPIO4, by default configured to provide the “GPS RTC sharing” function, must be connected to the RTC synchronization signal of the u-blox positioning receiver (i.e. the pin EXTINT0 of the u-blox GPS/GNSS receiver) on the application board, to provide an RTC (Real Time Clock) synchronization signal at the power up of the u-blox positioning receiver connected to the wireless module “GPS data ready” and “GPS RTC sharing” functions are not supported by all u-blox GPS/GNSS receivers HW or ROM/FW versions. Refer to the GPS Implementation Application Note [21] or to the Hardware Integration Manual of the u-blox GPS/GNSS receivers for the supported features. Figure 55Figure 55 illustrates an application circuit for SARA-G350 connection to a u-blox 1.8 V GPS/GNSS receiver: The SDA and SCL pins of the SARA-G350 module are directly connected to the relativerelated pins of the ublox 1.8 V GPS/GNSS receiver, with appropriate pull-up resistors. The GPIO3 and GPIO4 pins are directly connected respectively to TXD1 and EXTINT0 pins of the u-blox 1.8 V GPS/GNSS receiver providing “GPS data ready” and “GPS RTC sharing” functions. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 101 of 161 SARA-G3 series - System Integration Manual The GPIO2 pin is connected to the active-high enable pin of the voltage regulator that supplies the u-blox 1.8 V GPS/GNSS receiver providing the “GPS supply enable” function. A pull-down resistor is provided to avoid a switch on of the positioning receiver when the SARA-G350 module is switched off or in the reset state. The V_BCKP supply output of the SARA-G350 wireless module is connected to the V_BCKP backup supply input pin of the GPS/GNSS receiver to provide the supply for the GPS/GNSS real time clock and backup RAM when the VCC supply of the wireless module is within its operating range and the VCC supply of the GPS/GNSS receiver is disabled. This enables the u-blox GPS/GNSS receiver to recover from a power breakdown with either a Hot-start or a Warm-start (depending on the actual duration of the GPS/GNSS VCC outage) and to maintain the configuration settings saved in the backup RAM. SARA-G350 u-blox GPS/GNSS 1.8 V receiver V_BCKP V_BCKP GPS LDO Regulator 1V8 VCC OUT VMAIN IN 23 GPIO2 SDA2 26 SDA SCL2 27 SCL TxD1 24 GPIO3 EXTINT0 25 GPIO4 1V8 1V8 SHDN C1 GND R3 U1 R1 R2 Figure 55: DDC (I2C) application circuit for u-blox 1.8 V GPS/GNSS receiver Reference Description Part Number - Manufacturer R1, R2 R3 4.7 kΩ Resistor 0402 5% 0.1 W 47 kΩ Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp RC0402JR-0747KL - Yageo Phycomp U1 Voltage Regulator for GPS/GNSS Receiver See GPS/GNSS Receiver Hardware Integration Manual Table 31: Components for DDC (I2C) application circuit for u-blox 1.8 V GPS/GNSS receiver As an alternative to using an external voltage regulator, the V_INT supply output of SARA-G350 wireless modules can be used to supply a u-blox 1.8 V GPS/GNSS receiver of the u-blox 6 family (or later u-blox family). The V_INT supply is able to withstand the maximum current consumption of these positioning receivers. The V_INT supply output provides low voltage ripple (up to 15 mVpp) when the module is in active-mode or in connected-mode, but it provides higher voltage ripple (up to 90 mVpp) when the module is in the low power idle-mode with power saving configuration enabled by AT+UPSV (refer to u-blox AT Commands Manual [2]). According to the voltage ripple characteristic of the V_INT supply output: The power saving configuration cannot be enabled to properly supply by V_INT output any 1.8 V GPS/GNSS receiver of the u-blox 6 family and any 1.8 V GPS/GNSS receiver of the u-blox 7 family with TCXO The power saving configuration can be enabled to properly supply by V_INT output any 1.8 V GPS/GNSS receiver of the u-blox 7 family without TCXO Additional filtering may be needed to properly supply an external LNA, depending on the characteristics of the used LNA, adding a series ferrite bead and a bypass capacitor (e.g. the Murata BLM15HD182SN1 ferrite bead and the Murata GRM1555C1H220J 22 pF capacitor) at the input of the external LNA supply line. Refer to the GPS Implementation Application Note [21] for additional guidelines using the V_INT supply output of SARA-G350 wireless modules to supply a u-blox 1.8 V GPS/GNSS receiver. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 102 of 161 SARA-G3 series - System Integration Manual Figure 56Figure 56 illustrates the application circuit for SARA-G350 connection to a u-blox 3.0 V GPS/GNSS receiver: SDA and SCL pins of SARA-G350 are directly connected to the relativerelated pins of the u-blox 3.0 V GPS/GNSS receiver, with appropriate pull-up resistors: an I2C-bus Voltage Translator is not needed because SARA-G350 DDC (I C) pins are capable up to 3.3 V. GPIO3 and GPIO4 pins of SARA-G350 are connected to the u-blox 3.0 V GPS/GNSS receiver by means of a general purpose Voltage Translator, needed for SARA-G350 generic digital pins because only 1.8 V capable. GPIO2 is connected to the active-high enable pin of the external voltage regulator that supplies the u-blox 3.0 V GPS/GNSS receiver to enable or disable the 3.0 V GPS/GNSS supply. The V_BCKP supply output of SARA-G350 is directly connected to the V_BCKP backup supply input pin of the u-blox 3.0 V GPS/GNSS receiver as in the application circuit for a u-blox 1.8 V GPS/GNSS receiver. SARA-G350 u-blox GPS/GNSS 3.0 V receiver V_BCKP GPS LDO Regulator 3V0 VCC OUT V_BCKP VMAIN IN 23 GPIO2 SDA2 26 SDA SCL2 27 SCL 3V0 SHDN C1 3V0 GND R3 U1 R1 R2 Unidirectional Voltage Translator 3V0 VCCA C2 TP V_INT 24 GPIO3 25 GPIO4 C3 DIR1 TxD1 A1 B1 EXTINT0 A2 B2 DIR2 1V8 VCCB GND GPS data ready GPS RTC sharing OE U2 Figure 56: DDC (I2C) application circuit for u-blox 3.0 V GPS/GNSS receiver Reference Description Part Number – Manufacturer R1, R2 4.7 kΩ Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp R3 C2, C3 47 kΩ Resistor 0402 5% 0.1 W 100 nF Capacitor Ceramic X5R 0402 10% 10V RC0402JR-0747KL - Yageo Phycomp GRM155R71C104KA01 - Murata U1 Voltage Regulator for GPS/GNSS Receiver See GPS/GNSS Receiver Hardware Integration Manual U2 Generic Unidirectional Voltage Translator SN74AVC2T245 - Texas Instruments Table 32: Components for DDC (I C) application circuit for u-blox 3.0 V GPS/GNSS receiver ESD sensitivity rating of the DDC (I C) pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible points. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 103 of 161 SARA-G3 series - System Integration Manual 2.5.3.2 Guidelines for DDC (I C) layout design The DDC (I C) serial interface requires the same consideration regarding electro-magnetic interference as any other digital interface. Keep the traces short and avoid coupling with RF line or sensitive analog inputs, since the signals can cause the radiation of some harmonics of the digital data frequency. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 104 of 161 SARA-G3 series - System Integration Manual 2.6 Audio Interface 2.6.1 Analog Audio interface 2.6.1.1 Guidelines for microphone and speaker connection circuit design (headset / handset modes) SARA-G350 modules provide one analog audio input path and one analog audio output path: the same paths are used for both headset and handset modes, so that basically the same application circuit can be implemented for both headset and handset modes. Figure 57Figure 57 shows an application circuit for the analog audio interface in headset and handset modes, connecting a 2.2 k electret microphone and a 16 receiver / speaker: External microphone can be connected to the uplink path of the module, since the module provides supply and reference as well as differential signal input for the external microphone A 16 receiver / speaker can be directly connected to the balanced output of the module, since the differential analog audio output of the module is able to directly drive loads with resistance rating greater than 14 As in the example circuit in Figure 57Figure 57, follow the general guidelines for the design of an analog audio circuit for both headset and handset modes: Provide proper supply to the used electret microphone, providing a proper connection from the MIC_BIAS supply output to the microphone. It is suggested to implement a bridge structure: The electret microphone, with its nominal intrinsic resistance value, represents one resistor of the bridge. To achieve good supply noise rejection, the ratio of the two resistance in one leg (R2/R3) should be equal to the ratio of the two resistance in the other leg (R4/MIC), i.e. R2 has to be equal to R4 (e.g. 2.2 k ) and R3 has to be equal to the microphone nominal intrinsic resistance value (e.g. 2.2 k ). Provide a proper series resistor at the MIC_BIAS supply output and then mount a proper large bypass capacitor to provide additional supply noise filtering. See the R1 series resistor (2.2 k ) and the C1 bypass capacitor (10 µF). Do not place a bypass capacitor directly at the MIC_BIAS supply output, since proper internal bypass capacitor is already provided to guarantee stable operation of the internal regulator. Connect the reference of the microphone circuit to the MIC_GND pin of the module as a sense line. Provide a proper series capacitor at both MIC_P and MIC_N analog uplink inputs for DC blocking (as the C2 an C3 100 nF Murata GRM155R71C104K capacitors in Figure 57Figure 57). This provides a high-pass filter for the microphone DC bias with proper cut-off frequency according to the value of the resistors of the microphone supply circuit. Then connect the signal lines to the microphone. Formatted: English (U.S.) Provide proper parts on each line connected to the external microphone as noise and EMI improvements, to minimize RF coupling and TDMA noise, according to the custom application requirements. Mount an 82 nH series inductor with self resonance frequency ~1 GHz (e.g. Murata LQG15HS82NJ02) on each microphone line (L1 and L2 inductors in Figure 57Figure 57). Formatted: English (U.S.) Mount a 27 pF bypass capacitor (e.g. Murata GRM1555C1H270J) from each microphone line to solid ground plane (C4 and C5 capacitors in Figure 57Figure 57). Formatted: English (U.S.) Use a microphone designed for GSM applications, which typically has an internal built-in bypass capacitor. Connect the SPK_P and SPK_N analog downlink outputs directly to the receiver / speaker (which resistance rating must be greater than 14 ). Provide proper parts on each line connected to the receiver / speaker as noise and EMI improvments, to minimize RF coupling, according to EMC requirements of the custom application. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 105 of 161 SARA-G3 series - System Integration Manual Mount a 27 pF bypass capacitor (e.g. Murata GRM1555C1H270J) from each speaker line to solid ground plane (C6 and C7 capacitors in Figure 57Figure 57). Provide additional ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) if the analog audio lines will be externally accessible on the application device, according to EMC/ESD requirements of the custom application. Mount the protection close to an accessible point of the line (D1 and D2 in Figure 57Figure 57). SARA-G350 MIC_BIAS 46 R1 C1 MIC_P 49 MIC_N 48 R2 R4 C2 C3 Microphone Connector L1 R3 MIC L2 MIC_GND 47 J1 C4 C5 D1 Speaker Connector SPK SPK_P 44 SPK_N 45 J2 C6 C7 D2 Figure 57: Analog audio interface headset and handset mode application circuit Reference Description Part Number – Manufacturer C1 10 µF Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 – Murata C2, C3 C4, C5, C6, C7 100 nF Capacitor Ceramic X7R 0402 10% 16 V 27 pF Capacitor Ceramic C0G 0402 5% 25 V GRM155R71C104KA88 – Murata GRM1555C1H270JA01 – Murata D1, D2 J1 Low Capacitance ESD Protection Microphone Connector USB0002RP or USB0002DP – AVX Various Manufacturers J2 Speaker Connector Various Manufacturers L1, L2 LQG15HS82NJ02 – Murata MIC 82 nH Multilayer inductor 0402 (self resonance frequency ~1 GHz) 2.2 kΩ Electret Microphone R1, R2, R3, R4 SPK 2.2 kΩ Resistor 0402 5% 0.1 W 16 Ω Speaker RC0402JR-072K2L – Yageo Phycomp Various Manufacturers Various Manufacturers Table 33: Example of components for analog audio interface headset and handset mode application circuit If the analog audio interface is not used, the analog audio pins (MIC_BIAS, MIC_GND, MIC_P, MIC_N, SPK_P, SPK_N) can be left unconnected on the application board. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 106 of 161 Formatted: English (U.S.) SARA-G3 series - System Integration Manual 2.6.1.2 Guidelines for microphone and loudspeaker connection circuit design (hands-free mode) Figure 58Figure 58 shows an application circuit for the analog audio interface in hands-free mode, connecting a 2.2 k electret microphone and an 8 or 4 loudspeaker: External microphone can be connected to the uplink path of the module, since the module provides supply and reference as well as differential signal input for the external microphone Using a 8 or 4 loudspeaker for the hands-free mode, an external audio amplifier must be provided on the application board to amplify the low power audio signal provided by the downlink path of the module, so that the external audio amplifier will drive the 8 or 4 loudspeaker, since differential analog audio output of the module is able to directly drive loads with resistance rating greater than 14 As in the example circuit in Figure 58Figure 58, follow the general guidelines for the design of an analog audio circuit for hands-free mode: Provide proper supply to the used electret microphone, providing a proper connection from the MIC_BIAS supply output to the microphone. It is suggested to implement a bridge: The electret microphone, with its nominal intrinsic resistance value, represents one resistor of the bridge. To achieve good supply noise rejection, the ratio of the two resistance in one leg (R2/R3) should be equal to the ratio of the two resistance in the other leg (R4/MIC), i.e. R2 has to be equal to R4 (e.g. 2.2 k ) and R3 must be equal to the microphone nominal intrinsic resistance value (e.g. 2.2 k ). Provide a series resistor at the MIC_BIAS supply output and then mount a good bypass capacitor to provide additional supply noise filtering, as the R1 series resistor (2.2 k ) and the C1 bypass capacitor (10 µF). Do not place a bypass capacitor directly at the MIC_BIAS supply output, since proper internal bypass capacitor is already provided to guarantee stable operation of the internal regulator. Connect the reference of the microphone circuit to the MIC_GND pin of the module as a sense line. Provide a proper series capacitor at both MIC_P and MIC_N analog uplink inputs for DC blocking (C2 and C3 100 nF Murata GRM155R71C104K capacitors in Figure 58Figure 58). This provides a high-pass filter for the microphone DC bias with proper cut-off frequency according to the value of the resistors of the microphone supply circuit. Then connect the signal lines to the microphone. Provide proper parts on each line connected to the external microphone as noise and EMI improvements, to minimize RF coupling and TDMA noise, according to the custom application requirements. Mount an 82 nH series inductor with self resonance frequency ~1 GHz (e.g. Murata LQG15HS82NJ02) on each microphone line (L1 and L2 inductors in Figure 58Figure 58). Mount a 27 pF bypass capacitor (e.g. Murata GRM1555C1H270J) from each microphone line to solid ground plane (C4 and C5 capacitors in Figure 58Figure 58). Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) Use a microphone designed for GSM applications, which typically have internal built-in bypass capacitor. Provide a 47 nF series capacitor at both SPK_P and SPK_N analog downlink outputs for DC blocking (C8 and C9 Murata GRM155R71C473K capacitors in Figure 58Figure 58). Then connect the lines to the differential input of a proper external audio amplifier, differential output which must be connected to the or 4 loudspeaker. (See the Analog Devices SSM2305CPZ filter-less mono 2.8 W class-D Audio Amplifier in the circuit described in Figure 58Figure 58.) Provide proper parts on each line connected to the external loudspeaker as noise and EMI improvments, to minimize RF coupling, according to EMC requirements of the custom application. Mount a 27 pF bypass capacitor (e.g. Murata GRM1555C1H270J) from each loudspeaker line to solid ground plane (C6 and C7 capacitors in Figure 58Figure 58). Provide additional ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) if the analog audio lines will be externally accessible on the application device, according to EMC/ESD requirements of the custom application. The protection should be mounted close to an accessible point of the line (D1 and D2 parts in the circuit described in Figure 58Figure 58). UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 107 of 161 Formatted: English (U.S.) SARA-G3 series - System Integration Manual SARA-G350 MIC_BIAS 46 R1 C1 R2 R4 C2 MIC_P 49 C3 MIC_N 48 Microphone Connector L1 R3 L2 MIC_GND 47 J1 VCC C4 Audio Amplifier VDD SPK_P 44 SPK_N 45 C8 C9 R5 R6 MIC C10 C5 D1 C11 Loud-Speaker LSPK Connector OUT+ IN+ OUT- IN- J2 GND C6 U1 C7 D2 Figure 58: Analog audio interface hands-free mode application circuit Reference Description Part Number – Manufacturer C1, C10 C2, C3, C11 10 µF Capacitor Ceramic X5R 0603 20% 6.3 V 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM188R60J106ME47 – Murata GRM155R71C104KA88 – Murata C4, C5, C6, C7 27 pF Capacitor Ceramic C0G 0402 5% 25 V GRM1555C1H270JA01 – Murata C8, C9 D1, D2 47 nF Capacitor Ceramic X7R 0402 10% 16V Low Capacitance ESD Protection GRM155R71C473KA01 – Murata USB0002RP or USB0002DP – AVX J1 J2 Microphone Connector Speaker Connector Various Manufacturers Various Manufacturers L1, L2 82 nH Multilayer inductor 0402 (self resonance frequency ~1 GHz) LQG15HS82NJ02 – Murata LSPK 8 Loud-Speaker 2.2 kΩ Electret Microphone Various Manufacturers MIC R1, R2, R3, R4 R5, R6 2.2 kΩ Resistor 0402 5% 0.1 W 0 Ω Resistor 0402 5% 0.1 W RC0402JR-072K2L – Yageo Phycomp RC0402JR-070RL – Yageo Phycomp U1 Filter-less Mono 2.8 W Class-D Audio Amplifier SSM2305CPZ – Analog Devices Various Manufacturers Table 34: Example of components for analog audio interface hands-free mode application circuit If the analog audio interface is not used, the analog audio pins (MIC_BIAS, MIC_GND, MIC_P, MIC_N, SPK_P, SPK_N) can be left unconnected on the application board. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 108 of 161 SARA-G3 series - System Integration Manual 2.6.1.3 Guidelines for external analog audio device connection circuit design The differential analog audio input / output can be used to connect the module to an external analog audio device. Audio devices with a differential analog input / output are preferable, as they are more immune to external disturbances. Figure 59Figure 59 and Table 35Table 35 describe the application circuits, following the suggested circuit designin. Guidelines for the connection to a differential analog audio input: The SPK_P / SPK_N balanced output of the module must be connected to the differential input of the external audio device by means of series capacitors for DC blocking (e.g. 10 µF Murata GRM188R60J106M) to decouple the bias present at the module output, as described in the left side of Figure 59Figure 59 Formatted: English (U.S.) Guidelines for the connection to a single ended analog audio input: A proper differential to single ended circuit must be inserted from the SPK_P / SPK_N balanced output of the module to the single ended input of the external audio device, as described in the right side of Figure 59Figure 59: 10 µF series capacitors (e.g. Murata GRM188R60J106M) are provided to decouple the bias present at the module output, and a voltage divider is provided to properly adapt the signal level from the module output to the external audio device input Formatted: English (U.S.) Guidelines for the connection to a differential analog audio output: The MIC_P / MIC_N balanced input of the module must be connected to the differential output of the external audio device by means of series capacitors for DC blocking (e.g. 10 µF Murata GRM188R60J106M) to decouple the bias present at the module input, as described in the left side of Figure 59Figure 59 Formatted: English (U.S.) Guidelines for the connection to a single ended analog audio output: A proper single ended to differential circuit has to be inserted from the single ended output of the external audio device to the MIC_P / MIC_N balanced input of the module, as described in the right side of Figure 59Figure 59: 10 µF series capacitors (e.g. Murata GRM188R60J106M) are provided to decouple the bias present at the module input, and a voltage divider is provided to properly adapt the signal level from the external audio device output to the module input Formatted: English (U.S.) Additional guidelines for any connection: The DC-block series capacitor acts as high-pass filter for audio signals, with cut-off frequency depending on both the values of capacitor and on the input impedance of the device. For example: in case of differential input impedance of 600 , the two 10 µF capacitors will set the -3 dB cut-off frequency to 53 Hz, while for single ended connection to 600 external device, the cut-off frequency with just the single 10 µF capacitor will be 103 Hz. In both cases the high-pass filter has a low enough cut-off to not impact the audio signal frequency response Use a suitable power-on sequence to avoid audio bump due to charging of the capacitor: the final audio stage should be always enabled as last one The signal levels can be adapted by setting gain using AT commands (refer to the u-blox AT Commands Manual [2][2], +USGC, +UMGC), but additional circuitry must be inserted if the SPK_P / SPK_N output level of the module is too high for the input of the audio device or if the output level of the audio device is too high for MIC_P / MIC_N, as the voltage dividers present in the circuits described in the right side of Figure 59Figure 59 to properly adapt the signal level UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 109 of 161 Formatted: English (U.S.) Formatted: English (U.S.), Do not check spelling or grammar SARA-G3 series - System Integration Manual SARA-G350 SPK_P 44 SPK_N 45 Audio Device C1 C2 GND Analog IN (+) SPK_N 45 GND Audio Device C5 R1 C6 Analog IN R2 GND Reference MIC_BIAS 46 MIC_GND 47 MIC_N 48 SPK_P 44 Analog IN (-) MIC_BIAS 46 MIC_P 49 SARA-G350 MIC_GND 47 C3 C4 GND Analog OUT (+) MIC_P 49 Analog OUT (-) MIC_N 48 GND R3 C7 C8 Analog OUT R4 GND GND Figure 59: Application circuits to connect the module to audio devices with proper differential or single-ended input/output Reference Description Part Number – Manufacturer C1, C2, C3, C4, C5, C6, C7, C8 10 µF Capacitor X5R 0603 5% 6.3 V GRM188R60J106M – Murata R1, R3 R2, R4 0 Ω Resistor 0402 5% 0.1 W Not populated RC0402JR-070RL – Yageo Phycomp Table 35: Connection to an analog audio device 2.6.1.4 Guidelines for analog audio layout design Accurate analog audio design is very important to obtain clear and high quality audio. The GSM signal burst has a repetition rate of 217 Hz that lies in the audible range. A careful layout is required to reduce the risk of noise from audio lines due to both VCC burst noise coupling and RF detection. Guidelines for the uplink path, which is the most sensitive since the analog input signals are in the microVolts range, are the following: Avoid coupling of any noisy signal to microphone lines: it is strongly recommended to route microphone lines away from module VCC supply line, any switching regulator line, RF antenna lines, digital lines and any other possible noise source Keep ground separation from microphone lines to other noisy signals. Use an intermediate ground layer or vias wall for coplanar signals Route microphone signal lines as a differential pair embedded in ground to reduce differential noise pick-up. The balanced configuration will help reject the common mode noise Route microphone reference as a signal line since the MIC_GND pin is internally connected to ground as a sense line as the reference for the analog audio input Cross other signals lines on adjacent layers with 90° crossing Place bypass capacitor for RF very close to active microphone. The preferred microphone should be designed for GSM applications which typically have internal built-in bypass capacitor for RF very close to active device. If the integrated FET detects the RF burst, the resulting DC level will be in the pass-band of the audio circuitry and cannot be filtered by any other device Guidelines for the downlink path are the following: The physical width of the audio output lines on the application board must be wide enough to minimize series resistance since the lines are connected to low impedance speaker transducer Avoid coupling of any noisy signal to speaker lines: it is recommended to route speaker lines away from module VCC supply line, any switching regulator line, RF antenna lines, digital lines and any other possible noise source UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 110 of 161 SARA-G3 series - System Integration Manual Route speaker signal lines as a differential pair embedded in ground up to reduce differential noise pick-up. The balanced configuration will help reject the common mode noise Cross other signals lines on adjacent layers with 90° crossing Place bypass capacitor for RF close to the speaker 2.6.2 Digital Audio interface 2.6.2.1 Guidelines for digital audio circuit design SARA-G3 series I S digital audio interface can be connected to an external digital audio device for voice applications. The external digital audio device must act as an I S slave (since the SARA-G3 modules act as an I S master only), with compatible I S mode (i.e. PCM mode or Normal I S mode), I S sample rate and I S clock frequency. The external device must provide compatible voltage levels (1.80 V typ.), otherwise the lines must be connected by means of a proper unidirectional voltage translator (e.g. Texas Instruments SN74AVC4T774 or SN74AVC2T245). Figure 60Figure 60 shows an application circuit with a generic digital audio device. 1.8 V Digital Audio Device SARA-G350 I2S_TXD 35 I2S Data Input I2S_RXD 37 I2S Data Output I2S_CLK 36 I2S Clock I2S_WA 34 I2S Word Alignment GND GND Figure 60: I2S interface application circuit with a generic digital audio device Any external signal connected to the digital audio interface must be tri-stated or set low when the module is in power-down mode and during the module power-on sequence (at least until the activation of the V_INT supply output of the module), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the wireless module cannot be tri-stated or set low, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode and during the module power-on sequence. ESD sensitivity rating of I S interface pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting a general purpose ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible points. If the I S digital audio pins are not used, they can be left unconnected on the application board. 2.6.2.2 Guidelines for digital audio layout design The I S interfaces lines (I2S_CLK, I2S_RX, I2S_TX, I2S_WA) require the same consideration regarding electro-magnetic interference as the SIM card. Keep the traces short and avoid coupling with RF line or sensitive analog inputs. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 111 of 161 SARA-G3 series - System Integration Manual 2.7 General Purpose Input/Output (GPIO) 2.7.1.1 Guidelines for GPIO circuit design The following application circuits are suggested as a general guideline for the usage of the GPIO pins available with the SARA-G350 modules, according to the relative custom function. Network status indication: The pin configured to provide the “Network status indication” function, e.g. the GPIO1, can be connected on the application board to an input pin of an application processor or can drive a LED by a transistor with integrated resistors to indicate network status. GSM Tx burst indication: The GPIO1 pin, as configured to provide the “GSM Tx burst indication” function, can be connected on the application board to an input pin of an application processor to indicate when a GSM Tx burst/slot occurs. GPS supply enable: The pin configured to provide the “GPS supply enable” function (GPIO2 by default) has to be connected to the active-high enable pin (or the active-low shutdown pin) of the voltage regulator that supplies the u-blox GPS/GNSS receiver. GPS data ready: The GPIO3 pin, by default configured to provide the “GPS data ready” function, has to be connected to the data ready output of the u-blox GPS/GNSS receiver (i.e. the pin TXD1). GPS RTC sharing: The GPIO4 pin, by default configured to provide the “GPS RTC sharing” function, has to be connected to the RTC synchronization input of the u-blox GPS/GNSS receiver (i.e. the pin EXTINT0). Figure 61Figure 61 describes an application circuit for a typical usage of the GPIOs of SARA-G350 modules: Network indication function provided by the GPIO1 pin GPS supply enable function provided by the GPIO2 pin GPS data ready function provided by the GPIO3 pin GPS RTC sharing function provided by the GPIO4 pin Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 kΩ resistor on the board in series to the GPIO. ESD sensitivity rating of the GPIO pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) close to accessible points. Any external signal connected to the GPIOs must be tri-stated or set low when the module is in powerdown mode and during the module power-on sequence (at least until the activation of the V_INT supply output of the module), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the wireless module cannot be tri-stated or set low, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode and during the module poweron sequence. If the GPIO pins are not used, they can be left unconnected on the application board. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 112 of 161 SARA-G3 series - System Integration Manual u-blox GPS/GNSS 1.8 V receiver SARA-G350 LDO Regulator 3V8 IN GPIO2 23 GPS Supply Enable GPIO4 24 25 VCC SHDN R1 GPIO3 1V8 OUT GND C1 U1 GPS Data Ready TxD1 GPS RTC Sharing EXTINT0 3V8 R4 DL1 GPIO1 16 R2 Network Indicator T1 R3 Figure 61: GPIO application circuit Reference Description Part Number - Manufacturer R1 U1 47 kΩ Resistor 0402 5% 0.1 W Voltage Regulator for GPS/GNSS Receiver Various manufacturers See GPS/GNSS Module Hardware Integration Manual R2 R3 10 kΩ Resistor 0402 5% 0.1 W 47 kΩ Resistor 0402 5% 0.1 W Various manufacturers Various manufacturers R4 DL1 820 Ω Resistor 0402 5% 0.1 W LED Red SMT 0603 Various manufacturers LTST-C190KRKT - Lite-on Technology Corporation T1 NPN BJT Transistor BC847 - Infineon Table 36: Components for GPIO application circuit 2.7.1.1 Guidelines for GPIO layout design The general purpose input/output pins are generally not critical for layout. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 113 of 161 SARA-G3 series - System Integration Manual 2.8 Reserved pins (RSVD) SARA-G3 series modules have pins reserved for future use. All the RSVD pins, except pin number 33, can be left unconnected on the application board. Figure 62Figure 62 illustrates the application circuit. Pin 33 (RSVD) must be connected to GND. SARA-G3 series RSVD 33 RSVD Figure 62: Application circuit for the reserved pins (RSVD) 2.9 Module placement Optimize placement for minimum length of RF line and closer path from DC source for VCC. Make sure that RF and analog circuits are clearly separated from any other digital circuits on the system board. Provide enough clearance between the module and any external part. The heat dissipation during continuous transmission at maximum power can significantly raise the temperature of the application base-board below the SARA-G3 modules: avoid placing temperature sensitive devices close to the module. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 114 of 161 SARA-G3 series - System Integration Manual 2.10 Module footprint and paste mask Figure 63Figure 63 and Table 37Table 37 describe the suggested footprint (i.e. copper mask) and paste mask layout for SARA-G3 modules: the proposed land pattern layout reflects the modules’ pads layout, while the proposed stencil apertures layout is slightly different (see the F’’, H’’, I’’, J’’, O’’ parameters compared to the F’, H’, I’, J’, O’ ones). The Non Solder Mask Defined (NSMD) pad type is recommended over the Solder Mask Defined (SMD) pad type, implementing the solder mask opening 50 µm larger per side than the corresponding copper pad. The recommended solder paste thickness is 150 µm, according to application production process requirements. Pin 1 H’ ANT pin J’ Pin 1 I’ H’’ J’’ ANT pin I’’ M1 M1 M1 M1 M2 M2 O’ O’’ O’ O’’ Stencil: 150 µm H’ A H’’ A J’ F’ J’’ F’’ F’ F’’ Figure 63: SARA-G3 series modules suggested footprint and paste mask (application board top view) Parameter Value Parameter Value Parameter Value F’ F’’ 26.0 mm 16.0 mm 3.00 mm 2.00 mm 2.50 mm 1.05 mm 1.00 mm H’ H’’ I’ I’’ J’ J’’ 1.10 mm 0.80 mm 0.75 mm 1.50 mm 1.55 mm 0.30 mm 0.35 mm M1 M2 O’ O’’ 2.75 mm 2.75 mm 1.80 mm 3.60 mm 2.10 mm 1.10 mm 1.05 mm Table 37: SARA-G3 series modules suggested footprint and paste mask dimensions These are recommendations only and not specifications. The exact copper, solder and paste mask geometries, distances, stencil thicknesses and solder paste volumes must be adapted to the specific production processes (e.g. soldering etc.) of the customer. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 115 of 161 SARA-G3 series - System Integration Manual UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 116 of 161 SARA-G3 series - System Integration Manual 2.11 Thermal guidelines SARA-G3 series module operating temperature range and module thermal resistance are specified in the SARA-G3 series Data Sheet [1]. The most critical condition concerning module thermal performance is the uplink transmission at maximum power (data upload or voice call in connected-mode), when the baseband processor runs at full speed, radio circuits are all active and the RF power amplifier is driven to higher output RF power. This scenario is not often encountered in real networks; however the application should be correctly designed to cope with it. During transmission at maximum RF power the SARA-G3 series modules generate thermal power that can exceed 1 W: this is an indicative value since the exact generated power strictly depends on operating condition such as the number of allocated TX slot, transmitting frequency band, etc. The generated thermal power must be adequately dissipated through the thermal and mechanical design of the application. The spreading of the Module-to-Ambient thermal resistance (Rth,M-A) depends on the module operating condition (e.g. GSM or GPRS mode, transmit band): the overall temperature distribution is influenced by the configuration of the active components during the specific mode of operation and their different thermal resistance toward the case interface. Mounting a SARA-G3 series module on a 79 mm x 62 mm x 1.41 mm 4-Layers PCB with a high coverage of copper in still air conditions , the increase of the module temperature in different modes of operation, referred 10 to idle state initial condition , can be summarized as following: ~8 °C during a GSM voice call (1 TX slot, 1 RX slot) at max TX power ~12 °C during a GPRS data transfer (2 TX slots, 3 RX slots) at max TX power The Module-to-Ambient thermal resistance value and the relative increase of module temperature will be different for other mechanical deployments of the module, e.g. PCB with different dimensions and characteristics, mechanical shells enclosure, or forced air flow. The increase of thermal dissipation, i.e. the Module-to-Ambient thermal resistance reduction, will decrease the temperature for internal circuitry of SARA-G3 series modules for a given operating ambient temperature. This improves the device long-term reliability for applications operating at high ambient temperature. A few hardware techniques may be used to reduce the Module-to-Ambient thermal resistance in the application: Connect each GND pin with solid ground layer of the application board and connect each ground area of the multilayer application board with complete via stack down to main ground layer Provide a ground plane as wide as possible on the application board Optimize antenna return loss, to optimize overall electrical performance of the module including a decrease of module thermal power Optimize the thermal design of any high-power component included in the application, as linear regulators and amplifiers, to optimize overall temperature distribution in the application device Select the material, the thickness and the surface of the box (i.e. the mechanical enclosure of the application device that integrates the module) so that it provides good thermal dissipation Force ventilation air-flow within mechanical enclosure Refer to SARA-G3 series Data Sheet [1] for the Rth,M-A value in this application condition Temperature is measured by internal sensor of wireless module Steady state thermal equilibrium is assumed. The module’s temperature in idle state can be considered equal to ambient temperature 10 UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 117 of 161 SARA-G3 series - System Integration Manual Provide a heat sink component attached to the module top side, with electrically insulated / high thermal conductivity adhesive, or on the backside of the application board, below the wireless module For example, after the installation of a robust aluminum heat-sink with forced air ventilation on the back of the same application board described above, the Module-to-Ambient thermal resistance (Rth,M-A) is reduced up to the Module-to-Case thermal resistance (Rth,M-C) defined in the SARA-G3 series Data Sheet [1]. The effect of lower Rth,M-A can be seen from the module temperature increase, which now can be summarized as following: ~1 °C during a GSM voice call (1 TX slot, 1 RX slot) at the maximum TX power ~2 °C during a GPRS data transfer (2 TX slots, 3 RX slots) at the maximum TX power Beside the reduction of the Module-to-Ambient thermal resistance implemented by the hardware design of the application device integrating a SARA-G3 series module, the increase of module temperature can be moderated by the software implementation of the application. Since the most critical condition concerning module thermal power occurs when module connected-mode is enabled, the actual module thermal power depends, as module current consumption, on the radio access mode (GSM / GPRS), the operating band and the average TX power. A few software techniques may be implemented to reduce the module temperature increase in the application: Select by means of AT command (refer to the u-blox AT Commands Manual [2][2], +UCLASS command) the module’s GPRS multi-slot class which provides lower current consumption (refer to current consumption values reported in the SARA-G3 series Data Sheet [1][1]) Select by means of AT command (refer to the u-blox AT Commands Manual [2][2], +UBANDSEL command) the operating band which provides lower current consumption (refer to current consumption values reported in the SARA-G3 series Data Sheet [1][1]) Enable module connected-mode for a given time period and then disable it for a time period enough long to properly mitigate temperature increase UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 118 of 161 Formatted: English (U.S.), Hidden Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) Formatted: English (U.S.) SARA-G3 series - System Integration Manual 2.12 ESD guidelines 2.12.1 ESD immunity test overview The immunity of devices integrating SARA-G3 series modules to Electro-Static Discharge (ESD) is part of the Electro-Magnetic Compatibility (EMC) conformity, which is required for products bearing the CE marking, compliant with the R&TTE Directive (99/5/EC), the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms for device ESD immunity: ESD testing standard CENELEC EN 61000-4-2 [15] and the radio equipment standards ETSI EN 301 489-1 [16], ETSI EN 301 489-7 [17], ETSI EN 301 489-24 [18], which requirements are summarized in Table 38Table 38. The ESD immunity test is performed at the enclosure port, defined by ETSI EN 301 489-1 [16] as the physical boundary through which the electromagnetic field radiates. If the device implements an integral antenna, the enclosure port is seen defined as all insulating and conductive surfaces housing the device. If the device implements a removable antenna, the antenna port can be separated from the enclosure port. The antenna port includes the antenna element and its interconnecting cable surfaces. The applicability of the ESD immunity test to the whole device depends on the device classification as defined by ETSI EN 301 489-1 [16]. Applicability of the ESD immunity test to the relative device ports or the relative interconnecting cables to auxiliary equipments, depends on device accessible interfaces and manufacturer requirements, as defined by ETSI EN 301 489-1 [16]. Contact discharges are performed at conductive surfaces, while air discharges are performed at insulating surfaces. Indirect contact discharges are performed on the measurement setup horizontal and vertical coupling planes as defined in CENELEC EN 61000-4-2 [15]. For the definition of integral antenna, removable antenna, antenna port, device classification refer to ETSI EN 301 489-1 [16]. CENELEC EN 61000-4-2 [15] defines the contact and air discharges. Application Category Immunity Level All exposed surfaces of the radio equipment and ancillary equipment in a representative configuration Contact Discharge 4 kV Air Discharge 8 kV Table 38: Electro-Magnetic Compatibility ESD immunity requirements as defined by CENELEC EN 61000-4-2, ETSI EN 301 489-1, ETSI EN 301 489-7, ETSI EN 301 489-24 2.12.2 ESD immunity test of u-blox SARA-G3 series reference designs Although Electro-Magnetic Compatibility (EMC) certification is required for customized devices integrating SARA-G3 series modules for R&TTED and European Conformance CE mark, EMC certification (including ESD immunity) has been successfully performed on SARA-G3 series modules reference design according to CENELEC EN 61000-4-2 [15], ETSI EN 301 489-1 [16], ETSI EN 301 489-7 [17], ETSI EN 301 489-24 [18] European Norms. The EMC / ESD approved u-blox reference designs consist of a SARA-G3 series module soldered onto a motherboard which provides supply interface, SIM card, headset and communication port. An external antenna is connected to an SMA connector provided on the motherboard for the GSM antenna. Since an external antenna is used, the antenna port can be separated from the enclosure port. The reference design is not enclosed in a box so that the enclosure port is not indentified with physical surfaces. Therefore, some test cases cannot be applied. Only the antenna port is identified as accessible for direct ESD exposure. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 119 of 161 SARA-G3 series - System Integration Manual u-blox SARA-G3 series reference design implement all the ESD precautions described in section 2.12.3. Table 39Table 39 reports the u-blox SARA-G3 series reference designs ESD immunity test results, according to test requirements stated in the CENELEC EN 61000-4-2 [15], ETSI EN 301 489-1 [16], ETSI EN 301 489-7 [17] and ETSI EN 301 489-24 [18]. Category Application Immunity Level Contact Discharge to coupling planes (indirect contact discharge) Enclosure +4 kV / -4 kV Contact Discharges to conducted surfaces (direct contact discharge) Enclosure port Not Applicable Remarks Test not applicable to u-blox reference design because it does not provide enclosure surface. The test is applicable only to equipments providing conductive enclosure surface. Antenna port +4 kV / -4 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with conductive surface. Air Discharge at insulating surfaces Enclosure port Not Applicable Test not applicable to the u-blox reference design because it does not provide an enclosure surface. The test is applicable only to equipments providing insulating enclosure surface. Antenna port +8 kV / -8 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with insulating surface. Table 39: Enclosure ESD immunity level of u-blox SARA-G3 series modules reference designs 2.12.3 ESD application circuits The application circuits described in this section are recommended and should be implemented in the any device that integratinges a SARA-G3 series modules, according to the application board classification (see ETSI EN 301 489-1 [16]), to satisfy the requirements for ESD immunity test summarized in Table 38Table 38. Antenna interface The ANT pin of SARA-G3 series modules provides ESD immunity up to ±4 kV for direct Contact Discharge and up to ±8 kV for Air Discharge: no further precaution to ESD immunity test is needed, as implemented in the EMC / ESD approved reference design of SARA-G3 series modules. The antenna interface application circuit implemented in the EMC / ESD approved reference designs of SARA-G3 series modules is described in Figure 40Figure 40 in case of antenna detection circuit not implemented, and is described in Figure 41Figure 41 and Table 22Table 22 in case of antenna detection circuit implemented (section 2.3). RESET_N pin The following precautions are suggested for the RESET_N line of SARA-G3 series modules, depending on the application board handling, to satisfy ESD immunity test requirements: It is recommended to keep the connection line to RESET_N as short as possible UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 120 of 161 SARA-G3 series - System Integration Manual Maximum ESD sensitivity rating of the RESET_N pin is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the RESET_N pin is externally accessible on the application board. The following precautions are suggested to achieve higher protection level: A general purpose ESD protection device (e.g. EPCOS CA05P4S14THSG varistor array or EPCOS CT0402S14AHSG varistor) should be mounted on the RESET_N line, close to accessible point The RESET_N application circuit implemented in the EMC / ESD approved reference designs of SARA-G3 series modules is described in Figure 34Figure 34 and Table 20Table 20 (section 2.2.2). SIM interface The following precautions are suggested for SARA-G3 series modules SIM interface (VSIM, SIM_RST, SIM_IO, SIM_CLK pins), depending on the application board handling, to satisfy ESD immunity test requirements: A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470J) must be mounted on the lines connected to VSIM, SIM_RST, SIM_IO and SIM_CLK pins to assure SIM interface functionality when an electrostatic discharge is applied to the application board enclosure It is suggested to use as short as possible connection lines at SIM pins Maximum ESD sensitivity rating of SIM interface pins is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if SIM interface pins are externally accessible on the application board. The following precautions are suggested to achieve higher protection level: A low capacitance (i.e. less than 10 pF) ESD protection device (e.g. Tyco Electronics PESD0402-140) should be mounted on each SIM interface line, close to accessible points (i.e. close to the SIM card holder) The SIM interface application circuit implemented in the EMC / ESD approved reference designs of SARA-G3 series modules is described in Figure 45Figure 45 and Table 25Table 25 (section 2.4). Other pins and interfaces All the module pins that are externally accessible on the device integrating SARA-G3 series module should be included in the ESD immunity test since they are considered to be a port as defined in ETSI EN 301 489-1 [16]. Depending on applicability, to satisfy ESD immunity test requirements according to ESD category level, all the module pins that are externally accessible should be protected up to ±4 kV for direct Contact Discharge and up to ±8 kV for Air Discharge applied to the enclosure surface. The maximum ESD sensitivity rating of all the other pins of the module is 1 kV (Human Body Model according to JESD22-A114). Higher protection level could be required if the relativerelated pin is externally accessible on the application board. The following precautions are suggested to achieve higher protection level: A general purpose ESD protection device (e.g. EPCOS CA05P4S14THSG or EPCOS CT0402S14AHSG varistor) should be mounted on the relativerelated line, close to accessible point UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 121 of 161 SARA-G3 series - System Integration Manual 2.13 SARA-G350 ATEX integration in explosive atmospheres applications 2.13.1 General guidelines SARA-G350 ATEX modules are certified as components intended for use in potentially explosive atmospheres (refer to section 4.4 and refer to the ‘Approvals‘ section of the SARA-G3 series Data Sheet [1] for further details), with the following marking: Ex II 1G, Ex ia IIC/IIB According to the marking stated above, the SARA-G350 ATEX modules are certified as electrical equipment of: group ‘II’: intended for use in areas with explosive gas atmosphere other than mines susceptible to firedamp category ‘1G’: intended for use in zone 0 hazardous areas, in which explosive atmospheres caused by mixtures of air and gases, vapours or mists are continuously present, for long periods or frequently, so that the modules are also suitable for applications intended for use in zone 1 and zone 2 hazardous areas level of protection ‘ia’: intrinsically safe apparatus with very high level of protection, not capable of causing ignition in normal operation and with the application of one countable fault or a combination of any two countable fault plus those non-countable faults which give the most onerous condition subdivision ‘IIC/IIB’: intended for use in areas where the nature of the explosive gas atmosphere is considered very dangerous based on the Maximum Experimental Safe Gap or the Minimum Ignition Current ratio of the explosive gas atmosphere in which the equipment may be installed (typical gases are hydrogen, acetylene, carbon disulphide), so that the modules are also suitable for applications intended for use in subdivision IIB (typical gases are ethylene, coke oven gas and other industrial gases) and subdivision IIA (typical gases are industrial methane, propane, petrol and the majority of industrial gases) The temperature range of use of SARA-G350 ATEX modules is defined in the ‘Operating temperature range’ section of the SARA-G3 series Data Sheet [1]. Even if the SARA-G350 ATEX modules are certified as components intended for use in potentially explosive atmospheres as described above, the application device that integrates the module must be approved under all the certification schemes required by the specific application device to be deployed in the market as apparatus intended for use in potentially explosive atmospheres. The certification scheme approvals required for the application device integrating SARA-G350 ATEX modules, intended for use in potentially explosive atmospheres, may differ depending on the following topics: the country or the region where the application device must be deployed the classification of the application device in relation to the use in potentially explosive atmospheres the classification of the hazardous areas in which the application device is intended for use Any specific applicable requirement for the implementation of the appratus integrating SARA-G350 ATEX modules, intended for use in potentially explosive atmospheres, must be fulfilled according to the exact applicable standards: check the detailed requisites on the pertinent normatives for the application, as for example the IEC 60079-0 [27], IEC 60079-11 [28], IEC 60079-26 [29] standards. The certification of the application device that integrates a SARA-G350 ATEX module and the compliance of the application device with all the applicable certification schemes, directives and standards required for use in potentially explosive atmospheres are the sole responsibility of the application device manufacturer. The application device integrating a SARA-G350 ATEX module for use in potentially explosive atmospheres must be designed so that any circuit/part of the apparatus shall not invalidate the specific characteristics of the type of protection of the SARA-G350 ATEX module electrical equipment. The intrinsic safety ‘i’ type of protection of SARA-G350 ATEX modules is based on the restriction of electrical energy within equipment and of interconnecting wiring exposed to the explosive atmosphere to a level below that which can cause ignition by either sparking or heating effects. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 122 of 161 SARA-G3 series - System Integration Manual The following input and equivalent parameters must be considered integrating a SARA-G350 ATEX module in an application device intended for use in potentially explosive atmospheres: Total internal capacitance, Ci = 103 µF Total internal inductance, Li = 4.1 µH The module does not contain blocks which increase the voltage (e.g. like step-up, duplicators, boosters, etc.) The nameplate of SARA-G350 ATEX modules is described in the ‘Product labeling’ section of the SARA-G3 series Data Sheet [1]. Additional information can be found on the SARA-G350 ATEX modules’ certificate of compliancy for use in potentially explosive atmospheres available on our website (www.u-blox.com). The final enclosure of the application device integrating SARA-G350 ATEX modules, intended for use in potentially explosive atmospheres, must guarantee a minimum degree of ingress protection of IP20. 2.13.2 Guidelines for VCC supply circuit design The power supply ratings, average and pulse, must be considered in the design of the VCC supply circuit on the application device integrating SARA-G350 ATEX module, implementing proper circuits providing adequate maximum voltage and current to the VCC supply input of SARA-G350 ATEX modules, according to the specific potentially explosive gas atmosphere category subdivision where the apparatus is intended for use. The following maximum input and equivalent parameters must be considered in gas sub-division IIC: Ui = 3.8 V Ii = 1.6 A (burst) Pi = 2.5 W Ci = 103 µF Li = 4.1 µH The following maximum input and equivalent parameters must be considered in gas sub-divisions IIB, IIA: Ui = 4.2 V Ii = 2.5 A (burst) Pi = 2.5 W Ci = 103 µF Li = 4.1 µH Primary and secondary cells and batteries Cells and batteries incorporated into equipment with intrinsic safety 'i' protection to potentially explosive gas atmosphere shall conform to the requirements of the IEC 60079-0 [27] and IEC 60079-11 ATEX standards [28]. Shunt voltage limiters For Level of Protection ‘ia’, the application of controllable semiconductor components as shunt voltage limiting devices, for example transistors, thyristors, voltage/current regulators, etc., may be permitted if both the input and output circuits are intrinsically safe circuits or where it can be shown that they cannot be subjected to transients from the power supply network. In circuits complying with the above, two devices are considered to be an infallible assembly. For Level of Protection ‘ia’, three independent active voltage limitation semiconductor circuits may be used in associated apparatus provided the transient conditions of the clause 7.5.1 of IEC 60079-11 standard are met. These circuits shall also be tested in accordance with the clause 10.1.5.3 of the IEC 60079-11 standard [28]. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 123 of 161 SARA-G3 series - System Integration Manual Series current limiters The use of three series blocking diodes in circuits of Level of Protection ‘ia’ is permitted, however, other semiconductors and controllable semiconductor devices shall be used as series current-limiting devices only in Level of Protection ‘ib’ or ‘ic’ apparatus. However, for power limitation purposes, Level of Protection ‘ia’ apparatus may use series current limiters consisting of controllable and non-controllable semiconductor devices. The use of semiconductors and controllable semiconductor devices as current-limiting devices for spark ignition limitation is not permitted for Level of Protection ‘ia’ apparatus because of their possible use in areas in which a continuous or frequent presence of an explosive atmosphere may coincide with the possibility of a brief transient which could cause ignition. The maximum current that may be delivered may have a brief transient but will not be taken as Io, because the compliance with the spark ignition test of the clause 10.1 of IEC 60079-11 standard [28] would have established the successful limitation of the energy in this transient. Protection against polarity reversal Protection against polarity reversal shall be provided within intrinsically safe apparatus to prevent invalidation of the type of protection as a result of reversal of the polarity of supplies to that intrinsically safe apparatus or at connections between cells of a battery where this could occur. For this purpose, single diode shall be acceptable. Other considerations All the recommendations reported in the section 2.13.1 must be considered for the implementation of the VCC supply circuit on application integrating SARA-G350 ATEX modules intended for use in potentially explosive atmospheres. Any specific applicable requirement for the VCC supply circuit design must be fulfilled according to all the exact applicable standards for the apparatus. Check the detailed requisites on the pertinent normatives for the application apparatus, as for example the IEC 60079-0 [27], IEC 60079-11 [28], IEC 60079-26 [29] standards. 2.13.3 Guidelines for antenna RF interface design The RF output power of the SARA-G350 ATEX modules transmitter is compliant to all the applicable 3GPP / ETSI standards, with a maximum output of 2 W RF pulse power and 1.15 mJ RF pulse energy in 850/900 MHz bands and with a maximum output of 1 W RF pulse power and 0.58 mJ RF pulse energy in the 1800/1900 MHz bands according to the GSM/GPRS power classes stated in Table 2Table 2. The RF threshold power of the application device integrating a SARA-G350 ATEX module is defined, according to the IEC 60079-0 ATEX standard [27], as the product of the effective output power of the transmitter (the SARA-G350 ATEX module) multiplied by the antenna gain (implemented/used on the application device). The RF threshold power of the application device integrating a SARA-G350 ATEX module transmitter, according to the IEC 60079-0 ATEX standard [27], must not exceed the limits shown in Table 40Table 40. Gas group II subdivision RF threshold power limits according to the IEC 60079-0 ATEX standard IIA (a typical gas is propane) IIB (a typical gas is ethylene) 6.0 W 3.5 W IIC (a typical gas is hydrogen) 2.0 W Table 40: RF threshold power limits for the different gas group II subdivisions according to the IEC 60079-0 ATEX standard [27] The system antenna(s) implemented/used on the application device for SARA-G350 ATEX modules must be designed/selected so that the antenna gain (i.e. the combined transmission line, connector, cable losses and radiating element gain) multiplied by the output power of the transmitter (SARA-G350 ATEX module) does not exceed the limits shown in Table 40Table 40. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 124 of 161 SARA-G3 series - System Integration Manual 2.14 Schematic for SARA-G3 series module integration Figure 64Figure 64 is an example of a schematic diagram where a SARA-G350 module is integrated into an application board, using all the available interfaces and functions of the module. SARA-G350 330µF 100nF 10nF 51 VCC 52 VCC 53 VCC 56pF 15pF ANT 56 ANT_DET 62 10k GND External Antenna Connector 33pF 3V8 82nH 27pF ESD SIM Card Holder V_BCKP RTC back-up 100µF V_BCKP GND Application Processor Open Drain Output TP Open Drain Output SIM_DET 42 SW2 VSIM 41 CCVCC (C1) SIM_IO 39 CCIO (C7) SIM_CLK 38 CCCLK (C3) SIM_RST 40 CCRST (C2) 15 18 PWR_ON RESET_N 470k 47pF 47pF 47pF 47pF 100nF 3V8 1.8V DTE TXD 12 TXD RXD 13 RXD RTS 10 RTS CTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD GND GND 1.8V DTE TXD RXD 0Ω TP 0Ω TP SW1 CCVPP (C6) 100kΩ TP 1k TP V_INT IN GPIO2 23 SDA2 27 SCL2 GPIO3 24 TxD1 GPIO4 25 EXTINT0 MIC_BIAS 46 MIC_P 49 GND MIC_N 48 MIC_GND 47 2.2k 10uF 2.2k RSVD 31 RSVD SPK_P 44 SPK_N 45 2.2k 100nF Microphone 82nH 100nF 2.2k Network Indicator 33 4.7k 26 RXD_AUX GPIO1 4.7k GND SCL TXD_AUX 16 VCC OUT SDA 28 3V8 u-blox 1.8 V GPS/GNSS Receiver 1V8_GPS SHDN 47k 29 GND LDO Regulator GND (C5) ESD ESD ESD ESD ESD ESD 82nH Connector 27pF 27pF ESD ESD 27pF 27pF ESD ESD Speaker Connector 1.8V Digital Audio Device I2S_RXD 37 I2S Data Output I2S_CLK 36 I2S Clock 17 RSVD I2S_TXD 35 I2S Data Input 19 RSVD I2S_WA 34 I2S Word Alligment Figure 64: Example of schematic diagram to integrate SARA-G350 module in an application board, using all the interfaces UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 125 of 161 SARA-G3 series - System Integration Manual Figure 65Figure 65 is an example of a schematic diagram where a SARA-G300 / SARA-G310 module is integrated into an application board, using all the available interfaces and functions of the module. SARA-G300/G310 Connector 3V8 51 VCC 52 VCC 53 330µF 100nF 10nF 56pF 15pF VCC 56 RSVD 62 V_INT SIM_DET 42 SW2 VSIM 41 CCVCC (C1) SIM_IO 39 CCIO (C7) SIM_CLK 38 CCCLK (C3) SIM_RST 40 CCRST (C2) GND SIM Card Holder V_BCKP RTC back-up External Antenna ANT 100µF V_BCKP GND TP 1k SW1 CCVPP (C6) Application Processor 100kΩ TP Open Drain Output 15 PWR_ON 470k 47pF 47pF 47pF 47pF 100nF TP 18 RESET_N TXD 12 TXD RXD 13 RXD RTS 10 RTS CTS 11 CTS DTR DTR DSR DSR RI RI DCD DCD Open Drain Output 1.8V DTE RSVD 23 RSVD 26 RSVD 27 32K_OUT 24 RSVD 25 EXT32K 31 RSVD 46 RSVD 49 RSVD 48 RSVD 47 RSVD 44 RSVD 45 RSVD 37 RSVD 36 GND (C5) ESD ESD ESD ESD ESD ESD GND GND 1.8V DTE TXD RXD 0Ω TP 0Ω TP 29 TXD_AUX 28 RXD_AUX GND GND 16 RSVD 33 RSVD 17 RSVD RSVD 35 19 RSVD RSVD 34 Figure 65: Example of schematic diagram to integrate SARA-G300/G310 modules in an application board, using all the interfaces UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 126 of 161 SARA-G3 series - System Integration Manual 2.15 Design-in checklist This section provides a design-in checklist. 2.15.1 Schematic checklist The following are the most important points for a simple schematic check: DC supply must provide a nominal voltage at VCC pin above the minimum operating range limit. VCC supply should be clean, with very low ripple/noise: provide the suggested bypass capacitors, in particular if the application device integrates an internal antenna. VCC voltage must ramp from 2.5 V to 3.2 V within 4 ms to allow a proper switch-on of the module. Add a proper pull-up resistor (e.g. 4.7 k ) to V_INT or another proper 1.8 V supply on each DDC (I C) interface line, if the interface is used. Capacitance and series resistance must be limited on each line of the DDC (I C) interface. Connect the pin number 33 (RSVD) to ground. All unused pins can be left unconnected except the PWR_ON pin (its level must be properly fixed, e.g. adding a 100 k pull-up to V_BCKP) and the RSVD pin number 33 (it must be connected to GND). DC supply must be capable of providing 1.9 A current pulses, providing a voltage at VCC pin above the minimum operating range limit and with a maximum 400 mV voltage drop from the nominal value. Do not leave PWR_ON floating: fix properly the level, e.g. adding a proper pull-up resistor to V_BCKP. Do not apply loads which might exceed the limit for maximum available current from V_INT supply. Check that voltage level of any connected pin does not exceed the relative operating range. Capacitance and series resistance must be limited on each SIM signal to match the SIM specifications. Insert the suggested capacitors on each SIM signal and low capacitance ESD protections if accessible. Check UART signals direction, since the signal names follow the ITU-T V.24 Recommendation [9]. Provide accessible testpoints directly connected to the following pins: TXD_AUX and RXD_AUX pins, V_INT pin, PWR_ON and/or RESET_N pins, to allow the module firmware upgrade using the u-blox EasyFlash tool and to allow the trace log capture (debug purpose). Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 k the board in series to the GPIO when those are used to drive LEDs. resistor on Insert the suggested passive filtering parts on each used analog audio line. Check the digital audio interface specifications to connect a proper device. Provide proper precautions for ESD immunity as required on the application board. Any external signal connected to the UART interface, auxiliary UART interface, I S interfaces and GPIOs must be tri-stated or set low when the module is in power-down mode and during the module poweron sequence (at least until the activation of the V_INT supply output of the module), to avoid latch-up of circuits and let a proper boot of the module. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 127 of 161 SARA-G3 series - System Integration Manual 2.15.2 Layout checklist The following are the most important points for a simple layout check: Check 50 nominal characteristic impedance of the RF transmission line connected to the ANT pad (antenna RF input/output interface). Follow the recommendations of the antenna producer for correct antenna installation and deployment (PCB layout and matching circuitry). Ensure no coupling occurs between the RF interface and noisy or sensitive signals (primarily analog audio input/output signals, SIM signals, high-speed digital lines). VCC line should be wide and short. Route VCC supply line away from sensitive analog signals. Ensure proper grounding. Optimize placement for minimum length of RF line and closer path from DC source for VCC. Route analog audio signals away from noisy sources (primarily RF interface, VCC, switching supplies). The audio outputs lines on the application board must be wide enough to minimize series resistance. Keep routing short and minimize parasitic capacitance on the SIM lines to preserve signal integrity. 2.15.3 Antenna checklist Antenna termination should provide 50 characteristic impedance with V.S.W.R at least less than 3:1 (recommended 2:1) on operating bands in deployment geographical area. Follow the recommendations of the antenna producer for correct antenna installation and deployment (PCB layout and matching circuitry). Follow the additional guidelines for products marked with the FCC logo (United States only) reported in section 4.2.2 Follow the guidelines in section 2.3.2 to get proper antenna detection functionality, if required. UBX-13000995 - A1 Advanced InformationPreliminary Design-in Page 128 of 161 Formatted: Hidden SARA-G3 series - System Integration Manual 3 Handling and soldering No natural rubbers, no hygroscopic materials or materials containing asbestos are employed. 3.1 Packaging, shipping, storage and moisture preconditioning For information pertaining to reels and tapes, Moisture Sensitivity levels (MSD), shipment and storage information, as well as drying for preconditioning see the SARA-G3 series Data Sheet [1] and the u-blox Package Information Guide [24]. The SARA-G3 series modules are Electro-Static Discharge (ESD) sensitive devices. Ensure ESD precautions are implemented during handling of the module. 3.2 Soldering 3.2.1 Soldering paste Use of "No Clean" soldering paste is strongly recommended, as it does not require cleaning after the soldering process has taken place. The paste listed in the example below meets these criteria. Soldering Paste: OM338 SAC405 / Nr.143714 (Cookson Electronics) Alloy specification: 95.5% Sn / 3.9% Ag / 0.6% Cu (95.5% Tin / 3.9% Silver / 0.6% Copper) 95.5% Sn / 4.0% Ag / 0.5% Cu (95.5% Tin / 4.0% Silver / 0.5% Copper) Melting Temperature: 217 °C Stencil Thickness: 150 µm for base boards The final choice of the soldering paste depends on the approved manufacturing procedures. The paste-mask geometry for applying soldering paste should meet the recommendations in section 2.10 The quality of the solder joints on the connectors (’half vias’) should meet the appropriate IPC specification. 3.2.2 Reflow soldering A convection type-soldering oven is strongly recommended over the infrared type radiation oven. Convection heated ovens allow precise control of the temperature and all parts will be heated up evenly, regardless of material properties, thickness of components and surface color. Consider the "IPC-7530 Guidelines for temperature profiling for mass soldering (reflow and wave) processes, published 2001". Reflow profiles are to be selected according to the following recommendations. Failure to observe these recommendations can result in severe damage to the device! UBX-13000995 - A1 Advanced InformationPreliminary Handling and soldering Page 129 of 161 SARA-G3 series - System Integration Manual Preheat phase Initial heating of component leads and balls. Residual humidity will be dried out. Note that this preheat phase will not replace prior baking procedures. Temperature rise rate: max 3 °C/s If the temperature rise is too rapid in the preheat phase it may cause excessive slumping. Time: 60 – 120 s If the preheat is insufficient, rather large solder balls tend to be generated. Conversely, if performed excessively, fine balls and large balls will be generated in clusters. End Temperature: 150 - 200 °C If the temperature is too low, non-melting tends to be caused in areas containing large heat capacity. Heating/ reflow phase The temperature rises above the liquidus temperature of 217 °C. Avoid a sudden rise in temperature as the slump of the paste could become worse. Limit time above 217 °C liquidus temperature: 40 - 60 s Peak reflow temperature: 245 °C Cooling phase A controlled cooling avoids negative metallurgical effects (solder becomes more brittle) of the solder and possible mechanical tensions in the products. Controlled cooling helps to achieve bright solder fillets with a good shape and low contact angle. Temperature fall rate: max 4 °C/s To avoid falling off, modules should be placed on the topside of the motherboard during soldering. The soldering temperature profile chosen at the factory depends on additional external factors like choice of soldering paste, size, thickness and properties of the base board, etc. Exceeding the maximum soldering temperature and the maximum liquidus time limit in the recommended soldering profile may permanently damage the module. Preheat [°C] 250 Heating Peak Temp. 245°C Cooling [°C] 250 Liquidus Temperature 217 200 217 200 40 - 60 s End Temp. 150 - 200°C max 4°C/s 150 150 max 3°C/s 60 - 120 s Typical Leadfree Soldering Profile 100 50 100 50 Elapsed time [s] Figure 66: Recommended soldering profile SARA-G3 series modules must not be soldered with a damp heat process. UBX-13000995 - A1 Advanced InformationPreliminary Handling and soldering Page 130 of 161 SARA-G3 series - System Integration Manual 3.2.3 Optical inspection After soldering the SARA-G3 series modules, inspect the modules optically to verify that the module is properly aligned and centered. 3.2.4 Cleaning Cleaning the soldered modules is not recommended. Residues underneath the modules cannot be easily removed with a washing process. Cleaning with water will lead to capillary effects where water is absorbed in the gap between the baseboard and the module. The combination of residues of soldering flux and encapsulated water leads to short circuits or resistor-like interconnections between neighboring pads. Water will also damage the sticker and the inkjet printed text. Cleaning with alcohol or other organic solvents can result in soldering flux residues flooding into the two housings, areas that are not accessible for post-wash inspections. The solvent will also damage the sticker and the ink-jet printed text. Ultrasonic cleaning will permanently damage the module, in particular the quartz oscillators. For best results use a "no clean" soldering paste and eliminate the cleaning step after the soldering. 3.2.5 Repeated reflow soldering Only a single reflow soldering process is encouraged for boards with a SARA-G3 series module populated on it. The reason for this is the risk of the module falling off due to high weight in relation to the adhesive properties of the solder. 3.2.6 Wave soldering Boards with combined through-hole technology (THT) components and surface-mount technology (SMT) devices require wave soldering to solder the THT components. Only a single wave soldering process is encouraged for boards populated with SARA-G3 series modules. 3.2.7 Hand soldering Hand soldering is not recommended. 3.2.8 Rework Rework is not recommended. Never attempt a rework on the module itself, e.g. replacing individual components. Such actions immediately terminate the warranty. 3.2.9 Conformal coating ® Certain applications employ a conformal coating of the PCB using HumiSeal or other related coating products. These materials affect the HF properties of the SARA-G3 series modules and it is important to prevent them from flowing into the module. The RF shields do not provide 100% protection for the module from coating liquids with low viscosity, therefore care is required in applying the coating. Conformal Coating of the module will void the warranty. UBX-13000995 - A1 Advanced InformationPreliminary Handling and soldering Page 131 of 161 SARA-G3 series - System Integration Manual 3.2.10 Casting If casting is required, use viscose or another type of silicon pottant. The OEM is strongly advised to qualify such processes in combination with the SARA-G3 series modules before implementing this in the production. Casting will void the warranty. 3.2.11 Grounding metal covers Attempts to improve grounding by soldering ground cables, wick or other forms of metal strips directly onto the EMI covers is done at the customer's own risk. The numerous ground pins should be sufficient to provide optimum immunity to interferences and noise. u-blox gives no warranty for damages to the SARA-G3 series modules caused by soldering metal cables or any other forms of metal strips directly onto the EMI covers. 3.2.12 Use of ultrasonic processes SARA-G3 series modules contain components which are sensitive to Ultrasonic Waves. Use of any Ultrasonic Processes (cleaning, welding etc.) may cause damage to the module. u-blox gives no warranty against damages to the SARA-G3 series modules caused by any Ultrasonic Processes. UBX-13000995 - A1 Advanced InformationPreliminary Handling and soldering Page 132 of 161 SARA-G3 series - System Integration Manual 4 Approvals For the complete list of all the certification schemes approvals of SARA-G3 series modules and the corresponding declarations of conformity, refer to the u-blox web-site (http://www.u-blox.com). 4.1 Product certification approval overview Product certification approval is the process of certifying that a product has passed all tests and criteria required by specifications, typically called “certification schemes” that can be divided into three distinct categories: Regulatory certification Country specific approval required by local government in most regions and countries, as: CE (Conformité Européenne) marking for European Union FCC (Federal Communications Commission) approval for United States Industry certification Telecom industry specific approval verifying the interoperability between devices and networks: GCF (Global Certification Forum), partnership between European device manufacturers and network operators to ensure and verify global interoperability between devices and networks PTCRB (PCS Type Certification Review Board), created by United States network operators to ensure and verify interoperability between devices and North America networks Operator certification Operator specific approval required by some mobile network operator, as: AT&T network operator in United States Even if SARA-G3 modules are approved under all major certification schemes, the application device that integrates SARA-G3 modules must be approved under all the certification schemes required by the specific application device to be deployed in the market. The required certification scheme approvals and relative testing specifications differ depending on the country or the region where the device that integrates SARA-G3 series modules must be deployed, on the relative vertical market of the device, on type, features and functionalities of the whole application device, and on the network operators where the device must operate. The certification of the application device that integrates a SARA-G3 module and the compliance of the application device with all the applicable certification schemes, directives and standards are the sole responsibility of the application device manufacturer. SARA-G3 modules are certified according to all capabilities and options stated in the Protocol Implementation Conformance Statement document (PICS) of the module. The PICS, according to 3GPP TS 51.010-2 [14], is a statement of the implemented and supported capabilities and options of a device. The PICS document of the application device integrating a SARA-G3 module must be updated from the module PICS statement if any feature stated as supported by the module in its PICS document is not implemented or disabled in the application device, as for the following cases: if any RF band is disabled by AT+UBANDSEL command if the automatic network attach is disabled by AT+COPS command if the module’s GPRS multi-slot class is changed by AT+UCLASS command UBX-13000995 - A1 Advanced InformationPreliminary Approvals Page 133 of 161 SARA-G3 series - System Integration Manual 4.2 Federal Communications Commission and Industry Canada notice Federal Communications Commission (FCC) ID for the SARA-G3 series modules are: For SARA-G310 modules: XPYSARAG350 For SARA-G350 modules: XPYSARAG350 Industry Canada (IC) Certification Numbers for the SARA-G3 series modules are: For SARA-G310 modules: 8595A-SARAG350 For SARA-G350 modules: 8595A-SARAG350 4.2.1 Safety Warnings review the structure Equipment for building-in. The requirements for fire enclosure must be evaluated in the end product The clearance and creepage current distances required by the end product must be withheld when the module is installed The cooling of the end product shall not negatively be influenced by the installation of the module Excessive sound pressure from earphones and headphones can cause hearing loss No natural rubbers, no hygroscopic materials nor materials containing asbestos are employed 4.2.2 Declaration of Conformity – United States only This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: this device may not cause harmful interference this device must accept any interference received, including interference that may cause undesired operation Radiofrequency radiation exposure Information: this equipment complies with FCC radiation exposure limits prescribed for an uncontrolled environment for fixed and mobile use conditions. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the body of the user or nearby persons. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter except as authorized in the certification of the product. The gain of the system antenna(s) used for the SARA-G350 modules (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 8.39 dBi (850 MHz) and 3.11 dBi (1900 MHz) for mobile and fixed or mobile operating configurations. 4.2.3 Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by u-blox could void the user's authority to operate the equipment. Manufacturers of mobile or fixed devices incorporating the SARA-G350 modules are authorized to use the FCC Grants and Industry Canada Certificates of the SARA-G350 modules for their own final products according to the conditions referenced in the certificates. The FCC Label shall in the above case be visible from the outside, or the host device shall bear a second label stating: For SARA-G310 modules: "Contains FCC ID: XPYSARAG310XPYSARAG350" resp. [TBD] For SARA-G350 modules: "Contains FCC ID: XPYSARAG350" resp. The IC Label shall in the above case be visible from the outside, or the host device shall bear a second label stating: For SARA-G310 modules: "Contains IC: 8595A-SARAG310SARAG350" resp. [TBD] UBX-13000995 - A1 Advanced InformationPreliminary Approvals Page 134 of 161 Comment [smos1]: Can we change this to one line: For SARA-G310 and SARA-G350 modules: "Contains FCC ID: XPYSARAG350". SARA-G3 series - System Integration Manual For SARA-G350 modules: "Contains IC: 8595A-SARAG350" resp. Canada, Industry Canada (IC) Notices This Class B digital apparatus complies with Canadian CAN ICES-3 (B)/NMB-3(B)ICES-003 and RSS-210. Operation is subject to the following two conditions: Comment [smos2]: Can we change this to one line: For SARA-G310 and SARA-G350 modules: "Contains IC: 8595ASARAG350". this device may not cause interference this device must accept any interference, including interference that may cause undesired operation of the device Radio Frequency (RF) Exposure Information The radiated output power of the u-blox Wireless Module is below the Industry Canada (IC) radio frequency exposure limits. The u-blox Wireless Module should be used in such a manner such that the potential for human contact during normal operation is minimized. This device has been evaluated and shown compliant with the IC RF Exposure limits under mobile exposure conditions (antennas are greater than 20cm from a person's body). This device has been certified for use in Canada. Status of the listing in the Industry Canada’s REL (Radio Equipment List) can be found at the following web address: http://www.ic.gc.ca/app/sitt/reltel/srch/nwRdSrch.do?lang=eng Additional Canadian information on RF exposure also can be found at the following web address: http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf08792.html IMPORTANT: Manufacturers of portable applications incorporating the SARA-G310 / SARA-G350 modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable device. This is mandatory to meet the SAR requirements for portable devices. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Canada, avis d'Industrie Canada (IC) Cet appareil numérique de classe B est conforme aux normes canadiennes ICES-003CAN ICES-3 (B)/NMB-3(B) et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes: cet appareil ne doit pas causer d'interférence cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement Informations concernant l'exposition aux fréquences radio (RF) La puissance de sortie émise par l’appareil de sans fil u-blox Wireless Module est inférieure à la limite d'exposition aux fréquences radio d'Industrie Canada (IC). Utilisez l’appareil de sans fil ublox Wireless Module de façon à minimiser les contacts humains lors du fonctionnement normal. Ce périphérique a été évalué et démontré conforme aux limites d'exposition aux fréquences radio (RF) d'IC lorsqu'il est installé dans des produits hôtes particuliers qui fonctionnent dans des conditions d'exposition à des appareils mobiles (les antennes se situent à plus de 20 centimètres du corps d'une personne). Ce périphérique est homologué pour l'utilisation au Canada. Pour consulter l'entrée correspondant à l’appareil dans la liste d'équipement radio (REL - Radio Equipment List) d'Industrie Canada rendez-vous sur: http://www.ic.gc.ca/app/sitt/reltel/srch/nwRdSrch.do?lang=fra Field Code Changed Pour des informations supplémentaires concernant l'exposition aux RF au Canada rendez-vous sur: http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf08792.html Field Code Changed IMPORTANT: les fabricants d'applications portables contenant les modules SARA-G310 / SARA-G350 doivent faire certifier leur produit final et déposer directement leur candidature pour une UBX-13000995 - A1 Advanced InformationPreliminary Approvals Page 135 of 161 SARA-G3 series - System Integration Manual certification FCC ainsi que pour un certificat Industrie Canada délivré par l'organisme chargé de ce type d'appareil portable. Ceci est obligatoire afin d'être en accord avec les exigences SAR pour les appareils portables. Tout changement ou modification non expressément approuvé par la partie responsable de la certification peut annuler le droit d'utiliser l'équipement. UBX-13000995 - A1 Advanced InformationPreliminary Approvals Page 136 of 161 SARA-G3 series - System Integration Manual 4.3 R&TTED and European Conformance CE mark SARA-G3 series modules have been evaluated against the essential requirements of the 1999/5/EC Directive. In order to satisfy the essential requirements of the 1999/5/EC Directive, the modules are compliant with the following standards: Radio Frequency spectrum use (R&TTE art. 3.2): EN 301 511 V9.0.2 Electromagnetic Compatibility (R&TTE art. 3.1b): EN 301 489-1 V1.9.2 EN 301 489-7 V1.4.1 Health and Safety (R&TTE art. 3.1a) EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + AC:2011 EN 62311:2008 The conformity assessment procedure for all the SARA-G3 series modules except SARA-G350 ATEX modules, referred to in Article 10 and detailed in Annex IV of Directive 1999/5/EC, has been followed with the involvement of the following Notified Body number: 1909 Thus, the following marking is included in the product: 1909 The conformity assessment procedure for SARA-G350 ATEX modules, referred to in Article 10 and detailed in Annex IV of Directive 1999/5/EC, has been followed with the involvement of the following Notified Body number: 1304 Thus, the following marking is included in the product: 1304 There is no restriction for the commercialization of the SARA-G3 series modules in all the countries of the European Union. 4.4 SARA-G350 ATEX conformance for use in explosive atmospheres SARA-G350 ATEX modules are certified as components intended for use in potentially explosive atmospheres compliant to the following standards: IEC 60079-0: 2011 IEC 60079-11: 2011 IEC 60079-26: 2006 The certification number of SARA-G350 ATEX modules according to the ATEX directive 94/9/EC is: SIQ 13 ATEX 032 U The certification number of SARA-G350 ATEX modules according to the IECEx conformity assessment system is: IECEx SIQ 13.0004U According to the standards listed above, the SARA-G350 ATEX modules are certified with the following marking: Ex II 1G, Ex ia IIC/IIB UBX-13000995 - A1 Advanced InformationPreliminary Approvals Page 137 of 161 SARA-G3 series - System Integration Manual The temperature range for using SARA-G350 ATEX modules is defined in the ‘Operating temperature range’ section of the SARA-G3 series Data Sheet [1]. The RF radiating profile of SARA-G350 ATEX modules is compliant to all the applicable 3GPP / ETSI standards, with a maximum of 2 W RF pulse power and 1.15 mJ RF pulse energy according to the GSM/GPRS power class stated in Table 2Table 2. The nameplate of SARA-G350 ATEX modules is described in the ‘Product labeling’ section of the SARA-G3 series Data Sheet [1]. The following maximum input and equivalent parameters must be considered in sub-division IIC: Ui = 3.8 V Ii = 1.6 A (burst) Pi = 2.5 W Ci = 103 µF Li = 4.1 µH The following maximum input and equivalent parameters must be considered in sub-divisions IIB, IIA: Ui = 4.2 V Ii = 2.5 A (burst) Pi = 2.5 W Ci = 103 µF Li = 4.1 µH UBX-13000995 - A1 Advanced InformationPreliminary Approvals Page 138 of 161 SARA-G3 series - System Integration Manual 5 Product Testing 5.1 u-blox in-series production test u-blox focuses on high quality for its products. All units produced are fully tested. Defective units are analyzed in detail to improve the production quality. This is achieved with automatic test equipment, which delivers a detailed test report for each unit. The following measurements are done: Digital self-test (firmware download, Flash firmware verification, IMEI programming) Measurement of voltages and currents Adjustment of ADC measurement interfaces Functional tests (Serial interface communication, analog audio interface, real time clock, temperature sensor, antenna detection, SIM card communication) Digital tests (GPIOs, digital interfaces) Measurement and calibration of RF characteristics in all supported bands (Receiver S/N verification, frequency tuning of reference clock, calibration of transmitter and receiver power levels) Verification of RF characteristics after calibration (modulation accuracy, power levels and spectrum performance are checked to be within tolerances when calibration parameters are applied) Figure 67: Automatic test equipment for module tests 5.2 Test parameters for OEM manufacturer Because of the testing done by u-blox (with 100% coverage), an OEM manufacturer does not need to repeat firmware tests or measurements of the module RF performance or tests over analog and digital interfaces in their production test. An OEM manufacturer should focus on: Module assembly on the device; it should be verified that: Soldering and handling process did not damaged the module components All module pins are well soldered on device board There are no short circuits between pins UBX-13000995 - A1 Advanced InformationPreliminary Product Testing Page 139 of 161 SARA-G3 series - System Integration Manual Component assembly on the device; it should be verified that: Communication with host controller can be established The interfaces between module and device are working Overall RF performance test of the device including antenna Dedicated tests can be implemented to check the device. For example, the measurement of module current consumption when set in a specified status can detect a short circuit if compared with a “Golden Device” result. Module AT commands are used to perform functional tests (communication with host controller, check SIM card interface, check communication between module and GPS/GNSS, GPIOs, etc.) and to perform RF performance tests. 5.2.1 “Go/No go” tests for integrated devices A ‘Go/No go’ test is to compare the signal quality with a “Golden Device” in a position with excellent network coverage and after having dialed a call (refer to u-blox AT Commands Manual [2], AT+CSQ command: , parameters). These kinds of test may be useful as a ‘go/no go’ test but not for RF performance measurements. This test is suitable to check the communication with host controller and SIM card, the audio and power supply functionality and verify if components at antenna interface are well soldered. 5.2.2 Functional tests providing RF operation Overall RF performance test of the device including antenna can be performed with basic instruments such as a spectrum analyzer (or an RF power meter) and a signal generator using AT+UTEST command over AT interface. The AT+UTEST command gives a simple interface to set the module to Rx and Tx test modes ignoring GSM/GPRS signaling protocol. The command can set the module: In transmitting mode in a specified channel and power level in all supported modulation schemes (single slot GMSK) and bands In receiving mode in a specified channel to returns the measured power level in all supported bands Refer to the u-blox AT Commands Manual [2], for AT+UTEST command syntax description. Refer to the End user test Application Note [23], for AT+UTEST command user guide, limitations and examples of use. UBX-13000995 - A1 Advanced InformationPreliminary Product Testing Page 140 of 161 SARA-G3 series - System Integration Manual Wireless Antenna Application Processor AT Commands Wideband Antenna SARA-G3 series ANT TX IN Spectrum Analyzer OUT Signal Generetor Application Board Wireless Antenna Application Processor AT Commands Wideband Antenna SARA-G3 series ANT RX Application Board Figure 68: Setup with spectrum analyzer and signal generator for radiated measurement This feature allows the measurement of the transmitter and receiver power levels to check component assembly related to the module antenna interface and to check other device interfaces from which depends the RF performance. To avoid module damage during transmitter test, a proper antenna according to module specifications or a 50 termination must be connected to ANT pin. To avoid module damage during receiver test the maximum power level received at ANT pin must meet module specifications. The AT+UTEST command sets the module to emit RF power ignoring GSM/GPRS signalling protocol. This emission can generate interference that can be prohibited by law in some countries. The use of this feature is intended for testing purpose in controlled environments by qualified user and must not be used during the normal module operation. Follow instructions suggested in u-blox documentation. u-blox assumes no responsibilities for the inappropriate use of this feature. UBX-13000995 - A1 Advanced InformationPreliminary Product Testing Page 141 of 161 SARA-G3 series - System Integration Manual Example of production tests for OEM manufacturer: 1. Trigger TX GMSK burst at low Power Control Level (lower than 15) or a RX measure reporting to check: If ANT pin is soldered If ANT pin is in short circuit If the module was damaged during soldering process or during handling (ESD, mechanical shock…) If antenna matching components on application board are soldered If integrated antenna is correctly connected To avoid module damage during transmitter test when good antenna termination is not guaranteed, use a low Power Control Level (i.e. PCL lower or equal to 15). u-blox assumes no responsibilities for module damaging caused by an inappropriate use of this feature. 2. Trigger TX GMSK burst at maximum PCL: To check if the power supply is correctly assembled and is able to deliver the required current 3. Trigger TX GMSK burst: To measure current consumption To check if module components were damaged during soldering process or during handling (ESD, mechanical shock…) 4. Trigger RX measurement: To test receiver signal level. Assuming that there are no losses between ANT pin and input power source, be aware that the power level estimated by the module can vary approximately within 3GPP tolerances for the average value To check if module was damaged during soldering process or during handling (ESD, mechanical shock…) 5. Trigger TX GMSK burst and RX measurement to check: Overall RF performance of the device including antenna measuring TX and RX power levels UBX-13000995 - A1 Advanced InformationPreliminary Product Testing Page 142 of 161 SARA-G3 series - System Integration Manual Appendix A Migration between LISA and SARA modules A.1 Overview Migrating between LISA-U1, LISA-U2, LISA-C2 series and SARA-G3 series wireless modules designs is a fairly straight-forward procedure that allows customers to take maximum advantage of their hardware and software investments. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 LISA-C2 series Top View 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 10 55 11 54 12 53 13 52 14 51 15 50 16 49 17 48 18 47 19 46 20 45 21 44 22 43 23 42 24 41 25 40 26 39 27 GND V_BCKP GND V_INT RSVD GND GND GND DSR RI DCD DTR RTS CTS TXD RXD GND VUSB_DET PWR_ON GPIO1 GPIO2 RESET_N GPIO3 GPIO4 GND USB_DUSB_D+ GND GND VCC VCC VCC GND SPI_MRDY SPI_SRDY SPI_MISO SPI_MOSI SPI_SCLK RSVD / SPK_N RSVD / SPK_P RSVD GPIO5 VSIM SIM_RST SIM_IO SIM_CLK SDA SCL RSVD / I2S_RXD RSVD / I2S_CLK RSVD / I2S_TXD RSVD / I2S_WA RSVD / MIC_P RSVD / MIC_N LISA-U1 series Top View GND GND RSVD/ ANT_DET GND GND GND GND GND ANT GND GND 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 10 55 11 54 12 53 13 52 14 51 15 50 16 49 17 48 18 47 19 46 20 45 21 44 22 43 23 42 24 41 25 40 26 39 27 GND V_BCKP GND V_INT RSVD GND GND GND DSR RI DCD DTR RTS CTS TXD RXD GND VUSB_DET PWR_ON GPIO1 GPIO2 RESET_N GPIO3 GPIO4 GND USB_DUSB_D+ GND GND VCC VCC View VCC GND SPI_MRDY / GPIO14 SPI_SRDY / GPIO13 SPI_MISO / GPIO12 SPI_MOSI / GPIO11 SPI_SCLK / GPIO10 GPIO9 / I2S1_WA GPIO8 / I2S1_CLK RSVD / CODEC_CLK GPIO5 VSIM SIM_RST SIM_IO SIM_CLK SDA SCL RSVD / I2S_RXD RSVD / I2S_CLK RSVD / I2S_TXD RSVD / I2S_WA GPIO7 / I2S1_TXD GPIO6 / I2S1_RXD LISA-U2 series Top 28 29 30 31 32 33 34 35 36 37 38 28 29 30 31 32 33 34 35 36 37 38 28 29 30 31 32 33 34 35 36 37 38 GND GND GND GND GND GND GND GND GND GND GND GND GND VCC VCC VCC GND RSVD RSVD RSVD RSVD RSVD SPK_N SPK_P RSVD GPIO5 VSIM SIM_RST SIM_IO SIM_CLK RSVD RSVD PCM_DI PCM_CLK PCM_DO PCM_SYNC MIC_P MIC_N GND GND GND GND GND GND GND GND GND GND GND GND RSVD GND V_INT RSVD GND GND GND RSVD RI RSVD RSVD RTS CTS TXD RXD GND VUSB_DET PWR_ON GPIO1 GPIO2 RESET_N GPIO3 GPIO4 GND USB_DUSB_D+ GND GND GND GND GND GND GND GND GND GND GND 64 63 62 61 60 59 58 57 56 55 54 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 GND V_BCKP GND V_INT GND DSR RI DCD DTR RTS CTS TXD RXD GND PWR_ON RSVD/ GPIO1 RSVD RESET_N RSVD GND GND 53 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 47 11 45 44 Top View 42 13 82 83 84 38 18 20 40 39 16 19 43 41 81 15 17 46 SARA-G3 series 12 14 49 48 10 51 50 52 Pin 65-96: GND 37 36 85 86 87 88 89 90 91 92 93 94 95 96 21 35 34 33 VCC VCC VCC GND RSVD/ MIC_P RSVD/ MIC_N RSVD/ MIC_GND RSVD/ MIC_BIAS RSVD/ SPK_N RSVD/ SPK_P GND SIM_DET VSIM SIM_RST SIM_IO SIM_CLK RSVD/ I2S_RXD RSVD/ I2S_CLK RSVD/ I2S_TXD RSVD/ I2S_WA RSVD 22 23 24 25 26 27 28 29 30 31 32 44 43 42 41 40 39 GND RSVD/ GPIO2 32K_OUT/GPIO3 RSVD/ GPIO4 RSVD/ SDA RSVD/ SCL RXD_AUX TXD_AUX GND EXT32/ RSVD GND 76 75 74 73 72 71 70 69 68 67 66 GND GND RSVD/ ANT_DIV GND GND GND GND GND ANT GND GND GND GND RSVD GND GND GND GND GND ANT GND GND GND GND RSVD GND GND GND GND GND ANT GND GND SARA-G3 wireless modules (26.0 x 16.0 mm LGA) have a different form factor than LISA wireless modules (33.2 x 22.4 mm LCC), but the footprint for each SARA and LISA module has been developed so that all the pads on the same lateral edge of the antenna pin can be shared on the application board, due to the same pitch and nearly the same functions provided, as described in Figure 69Figure 69. Figure 69: LISA series vs. SARA-G3 series modules pin assignment: highlighted pads that can be shared on the application board This is the basis of the Nested Design concept: any SARA-G3, any LISA-U1, any LISA-U2, any or LISA-C2 module can be alternatively mounted on the same nested board as shown in Figure 70Figure 70, enabling straightforward development of products supporting either GSM/GPRS, W-CDMA or CDMA wireless technology with the same application board. UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 143 of 161 SARA-G3 series - System Integration Manual LISA SARA ANT pad NESTED APPLICATION BOARD Top Layer and Solder Mask LISA mounting option with LISA Paste Mask SARA mounting option with SARA Paste Mask Figure 70: Nested Design concept description: LISA and SARA modules alternatively mounted on the same application board The voltage level of all the digital interfaces of SARA-G3 and LISA modules is 1.8 V: this allows the direct connection from a 1.8 V external device (e.g. application processor) to all the modules. The following sections explains in details all the points to consider during the migration between LISA and SARA designs, implementing or not a nested design For further details regarding SARA-G3 and LISA modules characteristics, usage, or settings, refer to the relative relevant module datasheet [1], [3], [4], [5], System Integration Manual [6], [7], and AT commands manual [2], [8]. A.2 Checklist for migration Have you chosen the optimal SARA-G3 series module? For quad-band GSM/GPRS, full feature set, select the SARA-G350 module. For quad-band GSM/GPRS, reduced feature set, select the SARA-G310 module. For dual-band GSM/GPRS, reduced feature set, select the SARA-G300 module. Check SARA-G3 series modules hardware requirements Check power capabilities of the external supply circuit: SARA-G3 modules require large current pulses in connected-mode as well as LISA-U series modules when a 2G call is enabled. LISA-C2 series modules do not require large current pulses due to the CDMA channel access technology. Check supported bands for proper antenna circuit development: SARA-G3 modules frequency ranges are within LISA-U modules ranges, but LISA-C2 modules range is quite different. Check antenna detection requirements: SARA-G350 modules provide the antenna detection function implementing an external application circuit between ANT_DET and ANT pins. Check the module power-on requirements: Table 41Table 41 and relative section summarize differences between SARA-G3 series and LISA modules. Check the module requirements to enter low power idle-mode: SARA-G300 and SARA-G310 modules require a 32 kHz signal at EXT32K input, which for example can be provided by the 32K_OUT output. Check serial interfaces requirements: SARA-G3 modules provide UART interface for AT command, data communication, multiplexer functionality, FW upgrade over AT and provide auxiliary UART interface for FW upgrade using the u-blox EasyFlash tool and for Trace log capture (debug purpose). Check analog audio requirements: SARA-G350 modules do not provide DC blocking capacitors at the MIC_P / MIC_N input pins and provide supply output and local ground for an external microphone at the MIC_BIAS / MIC_GND pins. UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 144 of 161 SARA-G3 series - System Integration Manual Check digital audio requirements: SARA-G350 modules provide a 4-wire 1.8 V interface supporting PCM and Normal I2S modes, master role and fixed sample rate. Check internal active pull-up / down values at digital interface input pins and the current capability of digital interface output pins, since they are slightly different between SARA-G3 and LISA modules. Check SARA-G3 series modules software requirements Not all of the functionalities available with LISA modules are supported by all the SARA-G3 modules versions. SARA-G300 and SARA-G310 modules do not support: Audio interfaces, DDC (I C) interface, Antenna detection interface, GPIOs Low power idle-mode, if a 32 kHz signal at EXT32K input pin is not provided TCP/IP, UDP/IP, FTP, HTTP GPS/GNSS via Modem, AssistNow clients, Hybrid positioning and CellLocate functionalities Jamming detection TM UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 145 of 161 SARA-G3 series - System Integration Manual A.3 Software migration Software migration between SARA-G3 and LISA wireless modules is a straightforward procedure. Nevertheless there are some differences to be considered with firmware version. Each wireless module supports AT commands according to 3GPP standards: TS 27.007 [10], TS 27.005 [11], TS 27.010 [12] and the u-blox AT command extension. Backward compatibility has been maintained as far as possible. For the complete list of supported AT commands and their syntax refer to the relativerefer to the relevant AT commands manual of the module [2], [8]. A.4 Hardware migration SARA-G3 series modules have been designed with backward compatibility to LISA series modules in mind but some minor differences were unavoidable. These minor differences are however not relevant for the majority of the designs. The following subsections describe the hardware differences between the interfaces of SARA-G3 series modules and LISA series modules while Table 42Table 42 summarizes the detailed differences between the pins. A.4.1 Supply interfaces Module supply input (VCC) The same compatible external circuit can be implemented for SARA-G3 and LISA even if there are minor differences in the VCC input voltage ranges and some differences in the current consumption figures. The voltage provided must be within the normal operating range limits to allow module switch-on and must be above the minimum limit of the extended operating range to avoid module switch-off. For the detailed VCC input voltage ranges values refer to Table 42Table 42 or to the relative datasheet of the module [1], [3], [4], [5]. The SARA-G3 maximum average current consumption is lower than the LISA one due to the lower data rate or the different channel access technology. SARA-G3 modules require large current pulses in connected-mode as well as LISA-U series when a 2G call is enabled. LISA-C2 series do not require large current pulses due to the CDMA channel access technology. For the detailed current consumption values refer to the relativerefer to the relevant module datasheet of the module [1], [3], [4], [5]. Detailed supply circuit design-in guidelines are reported in section 2.1.1 and in the relative System Integration Manual of the module [6], [7]. RTC supply input/output (V_BCKP) The same compatible external circuit can be implemented for SARA-G3 series and LISA-U series even if there are minor differences in the V_BCKP typical output voltage and input voltage range as reported in Table 42Table 42 or in the relative datasheet of the module [1], [3], [4], [5]. LISA-C2 series do not provide V_BCKP RTC supply input/output as well as the whole RTC functionality. Interfaces supply output (V_INT) The same compatible external circuit can be implemented for SARA-G3 series and LISA series: there are no differences in the V_INT output characteristics. UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 146 of 161 SARA-G3 series - System Integration Manual A.4.2 System functions interfaces Module power-on SARA-G3 and LISA series power-on sequence is initiated in one of the ways summarized in Table 41Table 41. For more details, refer to section 1.6.1 or to the relative System Integration Manual of the module [6], [7]. SARA-G3 series LISA-C2 series LISA-U1 series LISA-U2 series Rising edge on the VCC pins to a valid voltage as module supply Rising edge on the VCC pins to a valid voltage as module supply with PWR_ON pin permanently low when VCC is applied Rising edge on the VCC pins to a valid voltage as module supply Rising edge on the VCC pins to a valid voltage as module supply Low level on the PWR_ON pin for appropriate time period Pre-programmed RTC alarm (external 32 kHz at EXT32K needed for SARA-G300/G310) Low pulse on the PWR_ON pin for appropriate time period Low pulse on the PWR_ON pin for appropriate time period Pre-programmed RTC alarm Low pulse on the PWR_ON pin for appropriate time period Pre-programmed RTC alarm RESET_N input pin released from the low level RESET_N input pin released from the low level Table 41: Summary of power on events among modules The same compatible external power-on circuit can be implemented for SARA-G3 series and LISA series even if there are minor differences in the PWR_ON input voltage levels ranges and in the low level time or low pulse time to switch-on the module, as reported in Table 42Table 42 or in the relative datasheet of the module [1], [3], [4], [5]. PWR_ON falling edge (i.e. low pulse) is required for LISA series, but it is not required for SARA-G3 series. External pull-up is not needed for LISA-C2 series since internal pull-up is provided. Module power-off SARA-G3 and LISA modules can all be all properly switched off by means of the AT+CPWROFF command. Additionally, Aall LISA-U2 modules, except LISA-U200-00S, modules can be additionally properly switched off by low pulse on the PWR_ON pin, as reported in Table 42Table 42 or in the relative datasheet of the module [5]. Module reset SARA-G3 series and LISA series modules reset can be performed in one of the following ways: Forcing a low level on the RESET_N pin, causing an “external” or “hardware” reset By means of the AT+CFUN command, causing an “internal” or “software” reset The same compatible external reset circuit can be implemented for SARA-G3 series and LISA series even if there are minor differences in the RESET_N input voltage levels ranges and in the low level time, as reported in Table 42Table 42 or in the relative datasheet of the module [1], [3], [4], [5]. Additional precautions are suggested for the RESET_N line of LISA-U series modules, depending on the application board handling, to satisfy ESD immunity test requirements as described in the LISA-U Series System Integration Manual [7]. External 32 kHz input and internal 32 kHz output The EXT32K input and the 32K_OUT output are available only on the SARA-G300 and SARA-G310 modules to provide the 32 kHz reference clock for the Real Time Clock (RTC) timing, used by the module processor to reach the low power idle-mode and provide the RTC functions. SARA-G350 and LISA-U modules are equipped with internal 32 kHz oscillator to provide the same functions. LISA-C2 series do not provide RTC and the relative functions. UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 147 of 161 SARA-G3 series - System Integration Manual A.4.3 Antenna interface RF interface for Tx/Rx antenna The same compatible external circuit can be implemented for SARA-G3 series and LISA series ANT pin even if there are some differences in the operating bands frequency ranges, as summarized in Figure 71Figure 71. 900 SARA-G300 800 850 900 900 950 880 850 SARA-G310 SARA-G350 960 850 900 950 950 1950 1700 1750 1800 1850 1900 1950 1700 1750 1800 1850 1900 II II 1900 1900 950 960 VIII 850 800 850 1850 VIII VI VI 850 850 1900 2050 2100 2150 2200 2050 2100 2150 2200 2050 2100 2150 2200 2000 1950 2000 1990 1900 900 2000 1800 1800 VIII 950 960 1800 1700 1750 1900 1800 1800 1850 1900 1950 2000 2050 2100 VIII 900 950 960 IV 1800 1700 2200 2170 IV 900 824 2150 1710 900 850 1750 1710 900 824 800 1800 1700 850 900 2200 1990 850 900 2150 1900 1950 1850 900 2100 1990 900 2050 1900 1710 894 850 2000 1800 850 800 LISA-U200 LISA-U230 1800 1900 900 824 LISA-U110 LISA-U130 LISA-U270 1900 1880 800 850 824 LISA-U100 LISA-U120 LISA-U260 1850 1900 960 800 800 1800 1800 1710 900 824 LISA-C200 1750 850 900 800 1800 1700 1750 II II 1900 1900 1800 1800 1850 1900 1950 2000 2050 1710 2100 2150 2200 2170 Figure 71: Summary of operating bands frequency ranges among modules An external application circuit can be implemented on the application device integrating LISA-U2 series modules to satisfy ESD immunity test requirements at the antenna port, as described in the LISA-U Series System Integration Manual [7]. The same application circuit is not applicable for SARA-G3 series, LISA-U1 series and LISA-C2 series. RF interface for Rx diversity antenna Only the LISA-U230 modules provide the RF input for Rx diversity antenna (ANT_DIV). SARA-G3, LISA-C2, LISA-U1 and the other LISA-U2 series modules do not support Rx diversity. Antenna detection interface An external application circuit can be implemented on the application device integrating SARA-G350 modules to provide antenna detection functionality, with a proper connection between the ANT_DET pin and the ANT pin, as described in section 2.3.2. LISA-U modules are equipped with internal circuit for antenna detection support. SARA-G300, SARA-G310 and LISA-C2 series modules do not support antenna detection. UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 148 of 161 SARA-G3 series - System Integration Manual A.4.4 SIM interface SIM interface The same compatible external circuit can be implemented for SARA-G3 and LISA modules: 1.8 V and 3.0 V SIM card / IC are supported. LISA-C2 modules do not need an external SIM for Sprint and Verizon mobile operators. LISA-C2 series SIM interface is hardware ready but the support of external SIM card / IC will be provided by the upcoming firmware releases. SIM detection interface The same compatible external circuit can be implemented for SARA-G3 and LISA modules: SIM detection function is provided by the SIM_DET pin on SARA-G3 modules and by the GPIO5 pin on LISA-U modules. SIM card hot insertion/removal is additionally supported by all LISA-U2 series except LISA-U200-00S. LISA-C2 modules do not support SIM detection. A.4.5 Serial interfaces UART interface The same compatible external circuit can be implemented for SARA-G3 and LISA modules: A 1.8 V unbalanced asynchronous serial port with RS-232 functionality is provided on SARA-G3 modules (for AT command, data communication, MUX functionality, FW upgrade over AT), LISA-C2 modules (for AT command, data communication, MUX functionality), LISA-U modules (for AT command, data communication, MUX functionality, FW upgrade over AT or using the u-blox EasyFlash tool). LISA-C2 modules do not support DSR, DCD and DTR functions. Table 42Table 42 and in relativethe module’s datasheet of the module [1], [3], [4], [5] report minor differences in the internal pull-ups and drivers strengths. These are the default settings of the UART interfaces: SARA-G3 modules: automatic baud rate and frame format detection LISA-U2 except LISA-U200-00S modules: one-shot automatic baud rate and frame format detection LISA-C2, LISA-U1 and LISA-U200-00S modules: 115200 b/s baud rate and 8N1 frame format For further details regarding UART interface settings refer to the relativemodule’s datasheet of the module [1], [3], [4], [5] and to the relative relevant AT commands manual of the module [2], [8]. UART AUX interface Only the SARA-G3 modules provide an auxiliary UART interface for FW upgrade using the u-blox EasyFlash tool and for Trace log capture (debug purpose). LISA modules do not provide an auxiliary UART interface. USB interface SARA-G3 modules do not provide a USB interface such asthat is available on LISA-U modules (High-Speed USB 2.0 for AT command, data communication, FW upgrade over AT or using the u-blox EasyFlash tool, and for Trace log capture) and on LISA-C2 modules (Full-Speed USB 2.0 for AT command, Data communication, FW upgrade). SPI interface SARA-G3 and LISA-C2 modules do not provide an SPI interface such asthat is available on LISA-U modules (5wire IPC interface for AT command, data communication, MUX functionality, FW upgrade over AT). DDC (I C) interface The same compatible external circuit can be implemented for SARA-G350 and LISA series: A 1.8 V DDC (I C bus compatible) interface is provided to communicate with u-blox GPS/GNSS receivers. UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 149 of 161 SARA-G3 series - System Integration Manual SARA-G300, SARA-G310 and LISA-U200-00S modules do not support the DDC (I C) interface. LISA-C2 modules will support the DDC (I C) interface byin the upcoming firmware releases. All LISA-U2 modules, except LISA-U200-00S, modules additionally support the communication with I C slaves by means of dedicated AT commands, other then than u-blox positioning receivers over the same DDC (I C) interface, by means of dedicated AT commands. A.4.6 Audio interfaces Analog audio interfaces Differential analog audio input is provided on the MIC_P / MIC_N pins of SARA-G350 modules (without internal DC blocking capacitor) and LISA-C2 series, LISA-U120, and LISA-U130 modules (with an internal DC blocking capacitor). Supply output and local ground for an external microphone is provided on the MIC_BIAS / MIC_GND pins of SARA-G350 modules only: the supply for an external microphone has to be provided by an external LDO linear regulator with the other modules. Differential analog audio output is provided on the SPK_P / SPK_N pins of SARA-G350, LISA-U120, LISA-U130 modules (16 ohm load capable) and LISA-C2 series modules (32 ohm load capable). SARA-G300/G310, LISA-U100/U110, LISA-U200-00S modules do not provide analog audio interfaces. LISA-U2 series modules do not provide analog audio interfaces, but analog audio can be provided with external audio codec connected to a digital audio interface of all LISA-U2 series modules except LISA-U200-00S modules (e.g. the 4-wire I S digital audio interface provided instead of the 4 analog audio pins). The modules provide control of the external codec by means of the I C interface and clock reference by means of the CODEC_CLK pin. For further details regarding analog audio interfaces characteristics, usage, and settings, refer to the relativerefer to the relevant module datasheet [1], [3], [4], [5], System Integration Manual 1.10.1, 2.6.1, [6], [7], and AT commands manual [2], [8]. Digital audio interfaces The dDigital audio interface is provided on the I2S_TXD, I2S_RXD, I2S_CLK, I2S_WA pins of SARA-G350 modules (1.8 V, PCM & Normal I2S modes, master, fixed sample rate) and LISA-U120/U130 and all LISA-U2 series modules except LISA-U200-00S modules (1.8 V, PCM & Normal I2S modes, master & slave, configurable sample rate)., and iIt is provided on the PCM_DO, PCM_DI, PCM_CLK, PCM_SYNC pins of LISA-C2 series modules (1.8 V, PCM): t. The same compatible external circuit can be implemented according to external digital audio device capabilities. An additional digital audio interface is provided on I2S1_TXD, I2S1_RXD, I2S1_CLK, I2S1_WA pins of all LISA-U2 series except LISA-U200-00S (1.8 V, PCM & Normal I2S modes, master & slave, configurable sample rate). SARA-G300/G310, LISA-U100/U110, LISA-U200-00S modules do not provide digital audio interfaces. For further details regarding digital audio interfaces characteristics, usage, and settings, refer to the relativerefer to the relevant module datasheet [1], [3], [4], [5], System Integration Manual 1.10.2, 2.6.2, [6], [7], and AT commands manual [2], [8]. A.4.7 GPIO pins The same compatible external circuit can be implemented for SARA-G350 and LISA series: four 1.8 V GPIOs are provided by SARA-G350 modules, providing the same functionalities as LISA series modules except Module Status and Operating Mode Indications. SIM detection function is provided by tThe SIM_DET pin provides the SIM detection function on SARA-G3 series modules instead ofrather than the GPIO5 pin as on LISA-U series modules. SARA-G300 and SARA-G310 modules do not provide GPIOs. UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 150 of 161 SARA-G3 series - System Integration Manual A.4.8 Reserved pins SARA-G3 series modules RSVD pin 33 must be connected to ground, as does the RSVD pin 5 on LISA series modules RSVD pin 5. Formatted: Don't adjust space between Latin and Asian text, Don't adjust space between Asian text and numbers UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 151 of 161 SARA-G3 series - System Integration Manual A.4.9 Pin-out comparison between LISA and SARA Table 42Table 42 summarizes the pin electrical differences between LISA and SARA wireless modules. Pin Name N° SARA-G3 series N° LISA-C2 series LISA-U1 series LISA-U2 series Power VCC 51-53 61-63 V_BCKP Normal op. range: 3.3 V – 4.4 V Extended op. range: Not applicable No high pulse current due to CDMA Not Available V_INT Normal op. range: 3.35 V – 4.5 V Extended op. range: 3.00 V – 4.5 V High pulse current due to GSM TDMA Output characteristics: 2.3 V typ, 2 mA max Input op. range: 1.0 V – 2.4 V Output characteristics: 1.8 V typ, 50 mA max Output characteristics: 1.8 V typ, 50 mA max Normal op. range: 3.4 V – 4.2 V Extended op. range: 3.1 V – 4.2 V High pulse current due to GSM TDMA Output characteristics: 2.3 V typ, 3 mA max Input op. range: 1.0 V – 2.5 V Output characteristics: 1.8 V typ, 50 mA max Normal op. range: 3.3 V – 4.4 V Extended op. range: 3.1 V – 4.5 V High pulse current due to GSM TDMA Output characteristics: 1.8 V typ, 3 mA max Input op. range: 1.0 V – 1.9 V Output characteristics: 1.8 V typ, 50 mA max RF input/output for Tx/Rx antenna Not Available 68 RF input/output for Tx/Rx antenna Not Available RF input/output for Tx/Rx antenna Not Available RF input/output for main Tx/Rx antenna LISA-U230 only: RF input for Rx diversity antenna Not Available Internal antenna detection circuit Internal antenna detection circuit Antenna ANT 56 ANT_DIV ANT_DET 74 62 SARA-G350 only: Input for antenna detection circuit PWR_ON 15 No internal pull-up L-level: -0.10 V – 0.65 V H-level: 2.00 V – 4.50 V ON L-level time: 5 ms min OFF L-level pulse time: Not Available 19 180 k internal pull-up L-level: -0.30 V – 0.30 V H-level: 2.00 V – 4.70 V ON L-level pulse time: 150 ms min OFF L-level pulse time: Not Available No internal pull-up L-level: -0.30 V –0.65 V H-level: 2.00 V – 4.50 V ON L-level pulse time: 5 ms min OFF L-level pulse time: Not Available No internal pull-up L-level: -0.30 V – 0.65 V H-level: 1.50 V – 4.40 V ON L-level pulse time: 50 µs min / 80 µs max OFF L-level pulse time: Not Available RESET_N 18 22 550 internal pull-up L-level: -0.30 V – 0.63 V H-level: 1.32 V – 2.10 V Reset L-level pulse time: 300 ms min 10 k internal pull-up L-level: -0.30 V – 0.65 V H-level: 1.69 V – 2.48 V Reset L-level pulse time: 50 ms min 10 k internal pull-up L-level: -0.30 V – 0.51 V H-level: 1.32 V – 2.01 V Reset L-level pulse time: 50 ms min EXT32K 31 Not Available: Internal reference for low power idle mode Not Available: Internal 32 kHz for RTC & low power idle mode Not Available: Internal 32 kHz for RTC & low power idle mode 32K_OUT 24 Internal diode & pull-up L-level: -0.30 V – 0.30 V H-level: 2.00 V – 4.70 V Reset L-level pulse time: 50 ms min (SARA-G350) 3 s min (SARA-G300/G310) SARA-G300/G310: 32 kHz input for RTC & low power idle mode SARA-G350: Not Available: Internal 32 kHz for RTC & low power idle mode SARA-G300/G310: 32 kHz output, only to feed the EXT32K input SARA-G350: Not Available Not Available Not Available Not Available System UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 152 of 161 SARA-G3 series - System Integration Manual Pin Name N° SARA-G3 series N° LISA-C2 series LISA-U1 series LISA-U2 series SIM SIM_CLK 38 1.8V / 3V SIM clock 47 1.8V / 3V SIM clock 1.8V / 3V SIM clock SIM_IO 39 1.8V / 3V SIM data Internal 4.7k pull-up 48 1.8V / 3V SIM data Internal 4.7k pull-up 1.8V / 3V SIM data Internal 4.7k pull-up SIM_RST 40 1.8V / 3V SIM reset 49 1.8V / 3V SIM reset 1.8V / 3V SIM reset VSIM 41 1.8V / 3V SIM supply 50 1.8V / 3V SIM supply 1.8V / 3V SIM supply SIM_DET 42 1.8 V, SIM detect input Inner pull-down: 103 µA 1.8V / 3V SIM clock (upcoming FW releases) 1.8V / 3V SIM data (upcoming FW releases) Internal 10k pull-up 1.8V / 3V SIM reset (upcoming FW releases) 1.8V / 3V SIM supply (upcoming FW releases) Not Available Provided by GPIO5: 1.8 V, SIM detect input Inner pull-down: 55 µA Provided by GPIO5: 1.8 V, SIM detect input Inner pull-down: 200 µA DSR Not Available RI 10 DCD 1.8 V, DSR output Driver strength: 6 mA 1.8 V, RI output Driver strength: 6 mA 1.8 V, DCD output Driver strength: 6 mA 11 1.8 V, RI output Driver strength: 6 mA Not Available 1.8 V, DSR output Driver strength: 4 mA 1.8 V, RI output Driver strength: 4 mA 1.8 V, DCD output Driver strength: 4 mA 1.8 V, DSR output Driver strength: 1 mA 1.8 V, RI output Driver strength: 2 mA 1.8 V, DCD output Driver strength: 2 mA DTR 12 Not Available RTS 10 13 CTS 11 1.8 V, DTR input Internal pull-up: -55 µA 1.8 V, Flow ctrl input Internal pull-up: -31 µA 1.8 V, Flow ctrl output Driver strength: 6 mA 1.8 V, Flow ctrl input Internal pull-up: -30 µA 1.8 V, Flow ctrl output Driver strength: 4 mA 1.8 V, DTR input Internal pull-up: -110 µA 1.8 V, Flow ctrl input Internal pull-up: -60 µA 1.8 V, Flow ctrl output Driver strength: 4 mA 1.8 V, DTR input Internal pull-up: -125 µA 1.8 V, Flow ctrl input Internal pull-up: -240 µA 1.8 V, Flow ctrl output Driver strength: 6 mA TXD 12 15 RXD 13 1.8 V, Data input Internal pull-up: -102 µA 1.8 V, Data output Driver strength: 5 mA 1.8 V, Data input Internal pull-up: -30 µA 1.8 V, Data output Driver strength: 4 mA 1.8 V, Data input Internal pull-up: -60 µA 1.8 V, Data output Driver strength: 4 mA 1.8 V, Data input Internal pull-up: -240 µA 1.8 V, Data output Driver strength: 6 mA UART AUX TXD_AUX 29 Not Available Not Available Not Available RXD_AUX 28 Not Available Not Available Not Available UART 14 16 1.8 V, Data input Internal pull-up: -102 µA 1.8 V, Data output Driver strength: 5 mA USB VUSB_DET Not Available 18 5 V, Supply detection 5 V, Supply detection 5 V, Supply detection USB_DUSB_D+ Not Available Not Available 26 27 Full-Speed USB 2.0 Full-Speed USB 2.0 High-Speed USB 2.0 High-Speed USB 2.0 High-Speed USB 2.0 High-Speed USB 2.0 SPI SPI_SCLK Not Available 55 Not Available SPI_MOSI Not Available 56 Not Available 1.8 V, Clock input Inner pull-down: 100 µA 1.8 V, Data input Internal pull-up: -220 µA 1.8 V, Clock input Inner pull-down: 200 µA 1.8 V, Data input Internal pull-up: -240 µA SPI_MISO Not Available 57 Not Available SPI_SRDY Not Available 58 Not Available SPI_MRDY Not Available 59 Not Available 1.8 V, Data output Driver strength: 2.5 mA 1.8 V, Flow ctrl output Driver strength: 4 mA 1.8 V, Flow ctrl input Inner pull-down: 55 µA 1.8 V, Data output Driver strength: 6 mA 1.8 V, Flow ctrl output Driver strength: 6 mA 1.8 V, Flow ctrl input Inner pull-down: 200 µA SARA-G350 only: 1.8 V, open drain Driver strength: 3 mA SARA-G350 only: 1.8 V, open drain Driver strength: 3 mA 45 1.8 V, open drain (upcoming FW releases) 1.8 V, open drain Driver strength: 1 mA 46 1.8 V, open drain (upcoming FW releases) 1.8 V, open drain Driver strength: 1 mA 1.8 V, open drain Driver strength: 1 mA LISA-U200-00S: N.A. 1.8 V, open drain Driver strength: 1 mA LISA-U200-00S: N.A. DDC (I2C) SCL 27 SDA 26 UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 153 of 161 SARA-G3 series - System Integration Manual Pin Name N° SARA-G3 series MIC_BIAS 46 MIC_GND 47 MIC_P 49 MIC_N 48 SPK_P 44 SARA-G350 only: 2.2 V supply output for external microphone SARA-G350 only: Local ground sense for external microphone SARA-G350 only: Differential input (+) No internal capacitor for DC blocking SARA-G350 only: Differential input (-) No internal capacitor for DC blocking SARA-G350 only: Differential output (+) 16 ohm load capable SPK_N 45 I2S_TXD 35 I2S_RXD 37 I2S_WA I2S_CLK N° LISA-C2 series LISA-U1 series LISA-U2 series Not Available Not Available Not Available Not Available Not Available Not Available 40 Differential input (+) 100 nF internal capacitor for DC blocking 39 Differential input (-) 100 nF internal capacitor for DC blocking 53 Differential output (+) 32 ohm load capable LISA-U120/U130 only: Not Available Differential input (+) 100 nF internal capacitor for DC blocking LISA-U120/U130 only: Not Available Differential input (-) 100 nF internal capacitor for DC blocking LISA-U120/U130 only: Not Available Differential output (+) 16 ohm load capable SARA-G350 only: Differential output (-) 16 ohm load capable 54 Differential output (-) 32 ohm load capable LISA-U120/U130 only: Differential output (-) 16 ohm load capable Not Available SARA-G350 only: 1.8 V, Data Out PCM / Normal I2S mode Driver strength: 5 mA SARA-G350 only: 1.8 V, Data In PCM / Normal I2S mode Inner pull-down: 103 µA 42 PCM_DO: 1.8 V, PCM Data Out 44 PCM_DI: 1.8 V, PCM Data In LISA-U120/U130 only: 1.8 V, Data Out PCM / Normal I2S mode Driver strength: 2.5 mA LISA-U120/U130 only: 1.8 V, Data In PCM / Normal I2S mode Inner pull-down: 100 µA 1.8 V, Data Out PCM / Normal I2S mode Driver strength: 2 mA LISA-U200-00S: N.A. 1.8 V, Data In PCM / Normal I2S mode Inner pull-down: 200 µA LISA-U200-00S: N.A. 34 SARA-G350 only: 1.8 V, Word align. Out Fixed frequency Driver strength: 6 mA 41 PCM_SYNC: 1.8 V, PCM Sync Out 36 SARA-G350 only: 1.8 V, Clock Out Fixed frequency Driver strength: 5 mA 43 PCM_CLK: 1.8 V, PCM Clock Out I2S1_WA Not Available 54 Not Available LISA-U120/U130 only: 1.8 V, Word align. In/Out Configurable frequency Inner pull-down: 100 µA Driver strength: 2.5 mA LISA-U120/U130 only: 1.8 V, Clock In/Out Configurable frequency Inner pull-down: 100 µA Driver strength: 2.5 mA Not Available I2S1_TXD Not Available 40 Not Available Not Available 1.8 V, Word align. In/Out Configurable frequency Inner pull-down: 200 µA Driver strength: 2 mA LISA-U200-00S: N.A. 1.8 V, Clock In/Out Configurable frequency Inner pull-down: 200 µA Driver strength: 2 mA LISA-U200-00S: N.A. 1.8 V, Data Out PCM / Normal I2S mode Driver strength: 1 mA LISA-U200-00S: N.A. 1.8 V, Data In PCM / Normal I2S mode Inner pull-down: 150 µA LISA-U200-00S: N.A. I2S1_CLK Not Available 53 Not Available Not Available 1.8 V, Word align. In/Out Configurable frequency Inner pull-down: 150 µA Driver strength: 1 mA LISA-U200-00S: N.A. I2S1_RXD Not Available 39 Not Available Not Available 1.8 V, Clock In/Out Configurable frequency Inner pull-down: 150 µA Driver strength: 1 mA LISA-U200-00S: N.A. Audio Analog Digital UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 154 of 161 SARA-G3 series - System Integration Manual Pin Name N° SARA-G3 series N° LISA-C2 series LISA-U1 series LISA-U2 series Not Available 52 Not Available Not Available 1.8 V, 13/26 MHz Out Driver strength: 4 mA LISA-U200-00S: N.A. SARA-G350 only: 1.8 V, configurable GPIO Default: Pad disabled Driver strength: 6 mA Inner pull-down: 51 µA SARA-G350 only: 1.8 V, configurable GPIO Default: GPS supply ena. Driver strength: 6 mA Inner pull-down: 51 µA SARA-G350 only: 1.8 V, configurable GPIO Default: GPS data ready Driver strength: 5 mA Inner pull-down: 27 µA SARA-G350 only: 1.8 V, configurable GPIO Default: GPS RTC shar. Driver strength: 6 mA Inner pull-down: 51 µA 20 1.8 V, configurable GPIO Default: Pad disabled Driver strength: 4 mA Inner pull-down: 30 µA 1.8 V, configurable GPIO Default: Pad disabled Driver strength: 1 mA Inner pull-down: 100 µA 1.8 V, configurable GPIO Default: Pad disabled Driver strength: 6 mA Inner pull-down: 200 µA 21 1.8 V, configurable GPIO Default: Pad disabled Driver strength: 4 mA Inner pull-down: 30 µA 1.8 V, configurable GPIO Default: GPS supply en. Driver strength: 1 mA Inner pull-down: 85 µA 1.8 V, configurable GPIO Default: GPS supply en. Driver strength: 1 mA Inner pull-down: 150 µA 23 1.8 V, configurable GPIO Default: Pad disabled Driver strength: 4 mA Inner pull-down: 30 µA 1.8 V, configurable GPIO Default: GPS data ready Driver strength: 4 mA Inner pull-down: 55 µA 1.8 V, configurable GPIO Default: GPS data ready Driver strength: 6 mA Inner pull-down: 200 µA 24 1.8 V, configurable GPIO Default: Pad disabled Driver strength: 4 mA Inner pull-down: 30 µA 1.8 V, configurable GPIO Default: GPS RTC sharing Driver strength: 6 mA Inner pull-down: 200 µA GPIO5 Not Available 51 GPIO6 Not Available 39 1.8 V, configurable GPIO Default: Pad disabled Driver strength: 4 mA Inner pull-down: 30 µA Not Available 1.8 V, configurable GPIO Default: GPS RTC sharing (4.7 k external pull-down required for RTC sharing) Driver strength: 4 mA Inner pull-down: 55 µA 1.8 V, configurable GPIO Default: SIM detection Driver strength: 2.5 mA Inner pull-down: 55 µA Not Available GPIO7 Not Available 40 Not Available Not Available GPIO8 Not Available 53 Not Available Not Available GPIO9 Not Available 54 Not Available Not Available GPIO10 Not Available 55 Not Available Not Available GPIO11 Not Available 56 Not Available Not Available 1.8 V, configurable GPIO Default: I2S1_TXD Driver strength: 1 mA Inner pull-down: 150 µA 1.8 V, configurable GPIO Default: I2S1_CLK Driver strength: 1 mA Inner pull-down: 150 µA 1.8 V, configurable GPIO Default: I2S1_WA Driver strength: 1 mA Inner pull-down: 150 µA 1.8 V, configurable GPIO Default: SPI_SCLK Driver strength: 6 mA Inner pull-down: 200 µA 1.8 V, configurable GPIO Default: SPI_MOSI Driver strength: 6 mA Inner pull-down: 200 µA GPIO12 Not Available 57 Not Available Not Available Other CODEC_CLK GPIO GPIO1 16 GPIO2 23 GPIO3 24 GPIO4 25 UBX-13000995 - A1 Advanced InformationPreliminary 1.8 V, configurable GPIO Default: SIM detection Driver strength: 6 mA Inner pull-down: 200 µA 1.8 V, configurable GPIO Default: I2S1_RXD Driver strength: 1 mA Inner pull-down: 150 µA 1.8 V, configurable GPIO Default: SPI_MISO Driver strength: 6 mA Inner pull-down: 200 µA Appendix Page 155 of 161 SARA-G3 series - System Integration Manual Pin Name SARA-G3 series N° LISA-C2 series LISA-U1 series LISA-U2 series GPIO13 N° Not Available 58 Not Available Not Available GPIO14 Not Available 59 Not Available Not Available 1.8 V, configurable GPIO Default: SPI_SRDY Driver strength: 6 mA Inner pull-down: 200 µA 1.8 V, configurable GPIO Default: SPI_MRDY Driver strength: 6 mA Inner pull-down: 200 µA Table 42: Summary of pin differences and compatibility level among modules UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 156 of 161 Formatted: English (U.S.) SARA-G3 series - System Integration Manual B Glossary 3GPP 3rd Generation Partnership Project ADC Analog to Digital Converter AP Application Processor AT AT Command Interpreter Software Subsystem, or attention CS Coding Scheme CSD Circuit Switched Data CTS Clear To Send DC Direct Current DCD Data Carrier Detect DCE Data Communication Equipment DCS Digital Cellular System DDC Display Data Channel interface DL Down-link (Reception) DRX Discontinuous Reception DSP Digital Signal Processing DSR Data Set Ready DTE Data Terminal Equipment DTM Dual Transfer Mode DTR Data Terminal Ready EMC Electro-magnetic Compatibility EMI Electro-magnetic Interference ESD Electro-static Discharge ESR Equivalent Series Resistance FEM Front End Module FOAT Firmware Over AT commands FTP File Transfer Protocol FTPS FTP Secure FW Firmware GMSK Gaussian Minimum Shift Keying modulation GND Ground GNSS Global Navigation Satellite System GPIO General Purpose Input Output GPRS General Packet Radio Service GPS Global Positioning System GSM Global System for Mobile Communication HF Hands-free HTTP HyperText Transfer Protocol HTTPS Hypertext Transfer Protocol over Secure Socket Layer HW Hardware I/Q In phase and Quadrature UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 157 of 161 SARA-G3 series - System Integration Manual Inter-Integrated Circuit interface IS Inter IC Sound interface IP Internet Protocol LCC Leadless Chip Carrier LDO Low-Dropout LGA Land Grid Array LNA Low Noise Amplifier M2M Machine-to-Machine MCS Modulation Coding Scheme N/A Not Applicable N.A. Not Available PA Power Amplifier PCM Pulse Code Modulation PCN / IN Product Change Notification / Information Note PCS Personal Communications Service PFM Pulse Frequency Modulation PMU Power Management Unit PSRAM Pseudo-Static RAM PWM Pulse Width Modulation RF Radio Frequency RI Ring Indicator RTC Real Time Clock RTS Request To Send SAW Surface Acoustic Wave SIM Subscriber Identification Module SMS Short Message Service SMTP Simple Mail Transfer Protocol SPI Serial Peripheral Interface SRF Self Resonant Frequency TBD To Be Defined TCP Transmission Control Protocol TDMA Time Division Multiple Access TP Test-Point UART Universal Asynchronous Receiver-Transmitter UDP User Datagram Protocol UICC Universal Integrated Circuit Card UL Up-link (Transmission) UMTS Universal Mobile Telecommunications System USB Universal Serial Bus UTRA UMTS Terrestrial Radio Access VCO Voltage Controlled Oscillator VSWR Voltage Standing Wave Ratio IC UBX-13000995 - A1 Advanced InformationPreliminary Appendix Page 158 of 161 SARA-G3 series - System Integration Manual Related documents [1] u-blox SARA-G3 series Data Sheet, Docu No GSM.G2-HW-12001 [2] [3] u-blox AT Commands Manual, Docu No WLS-SW-11000 u-blox LISA-C200 series Data Sheet, Docu No CDMA-2X-11001 [4] u-blox LISA-U1 series Data Sheet, Docu No 3G.G2-HW-10001 [5] [6] u-blox LISA-U2 series Data Sheet, Docu No 3G.G3-HW-11004 u-blox LISA-C200 & FW75-C200 System Integration Manual, Docu No CDMA-2X-11004 [7] u-blox LISA-U series System Integration Manual, Docu No 3G.G2-HW-10002 [8] [9] u-blox C200 AT Commands Manual, Docu No CDMA-2X-11002 ITU-T Recommendation V.24 - 02-2000 - List of definitions for interchange circuits between the Data Terminal Equipment (DTE) and the Data Circuit-terminating Equipment (DCE). http://www.itu.int/rec/T-REC-V.24-200002-I/en 3GPP TS 27.007 – AT command set for User Equipment (UE) (Release 1999) [10] [11] [12] 3GPP TS 27.005 – Use of Data Terminal Equipment – Data Circuit terminating; Equipment (DTE – DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) (Release 1999) 3GPP TS 27.010 – Terminal Equipment to User Equipment (TE-UE) multiplexer protocol (Release 1999) [13] I2C-Bus Specification Version 2.1 Philips Semiconductors (January 2000), http://www.nxp.com/acrobat_download/literature/9398/39340011_21.pdf [14] 3GPP TS 51.010-2 – Technical Specification Group GSM/EDGE Radio Access Network; Mobile Station (MS) conformance specification; Part 2: Protocol Implementation Conformance Statement (PICS) [15] CENELEC EN 61000-4-2 (2001): "Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test". [16] [19] ETSI EN 301 489-1 V1.8.1: “Electromagnetic compatibility and Radio spectrum Matters; EMC standard for radio equipment and services; Part 1: Common technical requirements” ETSI EN 301 489-7 V1.3.1 “Electromagnetic compatibility and Radio spectrum Matters; EMC standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)“ ETSI EN 301 489-24 V1.4.1 "Electromagnetic compatibility and Radio spectrum Matters; EMC standard for radio equipment and services; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for Mobile and portable (UE) radio and ancillary equipment" 3GPP TS 26.267 V10.0.0 – eCall Data Transfer; In-band modem solution; General description (Rel. 10) [20] Multiplexer Implementation Application Note, Docu No WLS-CS-11002 [21] [22] GPS Implementation Application Note, Docu No GSM.G1-CS-09007 Firmware Update Application Note, Docu No WLS-CS-11001 [23] End user test Application Note, Docu No WLS-CS-12002 [24] [25] u-blox Package Information Guide, Docu No GPS-X-11004 BS EN 16062:2011 – Intelligent transport systems – eSafety – eCall high level application requirements [26] ETSI TS 122 101 V8.7.0 – Service aspects; Service principles (3GPP TS 22.101 v.8.7.0 Rel. 8) [27] [28] IEC 60079-0 - Explosive atmospheres, Part 0: Equipment general requirements - 2011-06 IEC 60079-11 - Explosive atmospheres, Part 11: Equipment protection by intrinsic safety 'i' - 2011-06 [29] IEC 60079-26 - Explosive atmospheres, Part 26: Equipment with EPL Ga - 2006-08 [17] [18] Some of the above documents can be downloaded from u-blox web-site (http://www.u-blox.com). UBX-13000995 - A1 Advanced InformationPreliminary Related documents Page 159 of 161 Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Updated current consumption description Formatted ... Updated voice-band processing system block diagram Formatted ... Updated DDC (I2C) application circuit for 3V u-blox GPS/GNSS receivers Formatted ... Updated status to Preliminary Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... Formatted ... SARA-G3 series - System Integration Manual Revision history Revision Date Name Status / Comments Oct. 30, 2012 sses Initial Release Mar. 28, 2013 sses Updated status to Advance Information Updated suggested paste mask Apr. 12, 2013 lpah (Last revision with old doc number, GSM.G2-HW-12003) Jul. 03, 2013 sses Updated status to Advance Information Added integration description for SARA-G350 ATEX modules Updated SARA-G300 / SARA-G310 supported features: Circuit Switched Data, GPRS multi-slot class 10, 32K_OUT pin, Current consumption A1 Aug. 08, 2013 UBX-13000995 - A1 lpah Updated status to Preliminary. FW version for SARA-G300-00S and SARA-G310-00S is 08.58. Advanced InformationPreliminary Revision history Page 160 of 161 SARA-G3 series - System Integration Manual Contact For complete contact information visit us at www.u-blox.com. u-blox Offices North, Central and South America u-blox America, Inc. Phone: E-mail: +1 703 483 3180 info_us@u-blox.com Regional Office West Coast: Phone: +1 408 573 3640 E-mail: info_us@u-blox.com Headquarters Europe, Middle East, Africa Asia, Australia, Pacific u-blox AG Phone: E-mail: Support: Phone: E-mail: Support: +41 44 722 74 44 info@u-blox.com support@u-blox.com Technical Support: Phone: E-mail: +1 703 483 3185 support_us@u-blox.com u-blox Singapore Pte. Ltd. +65 6734 3811 info_ap@u-blox.com support_ap@u-blox.com Regional Office Australia: Phone: +61 2 8448 2016 E-mail: info_anz@u-blox.com Support: support_ap@u-blox.com Formatted: Space Before: 6 pt, After: 0 pt Regional Office China (Beijing): Phone: +86 10 68 133 545 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Formatted: Space Before: 2 pt, After: 2 pt Formatted: Font: Not Bold Formatted: Font: Not Bold Regional Office China (Shenzhen): Phone: +86 755 8627 1083 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office India: Phone: +91 959 1302 450 E-mail: info_in@u-blox.com Support: support_in@u-blox.com Regional Office Japan: Phone: +81 3 5775 3850 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Korea: Phone: E-mail: Support: +82 2 542 0861 info_kr@u-blox.com support_kr@u-blox.com Regional Office Taiwan: Phone: +886 2 2657 1090 E-mail: info_tw@u-blox.com Support: support_tw@u-blox.com UBX-13000995 - A1 Advanced InformationPreliminary Contact Page 161 of 161
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 161 Language : it-IT Tagged PDF : Yes Title : SARA-G3 series Subject : System Integration Manual Creator : Microsoft® Office Word 2007 Create Date : 2013:08:22 14:56:59+02:00 Modify Date : 2013:08:22 14:56:59+02:00 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools