HWASUNG SYSTEM HP-500 Thermal Mobile Printer User Manual
HWASUNG SYSTEM CO., LTD Thermal Mobile Printer
User Manual
Technical Manual (Model : HP-500) CAUTION • Please do not disassemble / reorganize the product. • Please do not the remove the paper jam during power on. • Pleased do not exceed the standard power voltage. • Please do not wash off the product. • Please do not press / shock the product. • Please do not put the product at the moist (humid) condition. • Please contact us if there is any problem. • Please power off once remove the paper jam. • Please clear the air / open the disclosed place. • Please set the product without damage enviornment. • Please set the product at the stable place. • Pleaes keep the requires as necessary as general electrics. Title HP-500 Ver 1 Rev. Page Ver1.0 P.1 목 차 1. Printer features & External dimension 1-1) Name of each parts 1-2) Operation Part 2. Operation 2-1) Replacing the roll of paper 2-2) Self test 2-3) Communicatino Setting up 2-4) HEX Dump 2-5) Update 2-6) Memory switch 2-7) Way of connecting WiFi or Bluetoorh (RF Interface) 10 13 3. Genearl Specification 3-1) Specification 3-2) Font 3-3) Inner Buffer 3-4) Electronical Spec 3-5) Operation condition 3-6) MCBF 13 13 13 13 13 13 13 4. Interface Specification 4-1)RS-232C 4-2)USB 4-3)WiFi 4-4)BlueTooth 14 14 14 14 14 5. Command 15 6.Windows Driver 6-1) Set up the function 6-2) Set up the paper 6-3) Set up the new paper 40 40 41 42 7. USB User Interface 7-1) functions 7-2) Caution for using USB Interface 44 44 46 Title HP-500 Ver 1 Rev. Page Ver1.0 P.2 1. Printer features & External Dimension 1-1) Name of each parts 1. Button and LED 2. Open Lever 3. Maual Cutter 4. Battery 5. DC Connect 6. USB/RS232C Interface Title HP-500 Ver 1 Rev. Page Ver1.0 P.3 1-2) Operation Parts Battery Power BlueTooth WiFi FEED Error * Battary State 3 light is “ Full “ charged. 2 light is “ Middle “ Charged 1 light is “ Low “ it needed to be charged. If the light in Error LED is “ Very Low “ in a battary * Power Power on : Please press the button for 1 sec more. Power off : Please press the button for 1 sec more. * FEED Paper feeding . * Error If there is something worng, it will be light as Red when there is no paper or out of bettary * WiFi and Bluetooth When operating WiFi or BlueTooth, the LED indicator will be lighting. * Setting the Lable. You can use the label paper after setting label option. ① Power on the printer ② Open the paper cover and Press the FEED button for 2 seconds. ③ When Melody is alaming, Put the paper of label in the printer and close the paper cover. When it comes back to Receipt Option, Please follow this step again. Title HP-500 Ver 1 Rev. Page Ver1.0 P.4 2. Operation 2-1) Replacing the roll of paper. The paper setting up is as below. ① Open the cover in Mobile Printer by Lever ② Please insert the paper, till the paper comes out from the cover. Lever ③ Close the cover and cut the extra paper. Title HP-500 Ver 1 Rev. Page Ver1.0 P.5 2-2 ) Selftest Please turn off and on the power, while you press down the feed button. And you can see the Error Led light kept then the following informations are being feeded. ****************************** HP-500 Control Board Firmware :: Ver0 .45 Create : 20XX/XX/XX ****************************** Model. Firmware version / creare date. Printer information. Serial I/F information WiFi information Printer Information Battery Volt : 7.7(V) Hex Dump Mode : OFF Print Density : Normal Melody Sound : ON Paper Type : Receipt Wireless Type : WiFi / BlueTooth Power off time : 10 Minute Tear Bar : 5 Pitch Serial I/F Information Baud Rate : 9600 Date Bit : 8 bit Partiy : None Stop Bit : 1 or 2 Flow Control : RTS-CTS(DTR-DSR) WiFi Information WiFi Mode : AP Mode IP Address : 192.168.012.101 Gateway : 192.168.012.001 SSID : HWASUNG_4E:8E:EE SECURITY KEY : 12345678 Title HP-500 Ver 1 Rev. Page Ver1.0 P.6 2-3 ) Communication setting Set the printer function and communication condition between host by memory switch utility program. ※ Note : Setting ereases all contents in memory switch, so code page and print optionshall be set again. 1 ) Manual setting Turn on the printer at initial setting mode. ※ Method to go initial setting mode [ Press and hold FEED button and then turn on power pressing 2 or more seconds, then PE LED and ERROR LED blinks by turns and it is switched to initial setting mode (9600 BPS, PARITY NONE, HARDWARE HANDSHAKE).] In manual setting, considering of communication condition is not required. 2 ) After switched to initial setting mode, followings will be printed. [Menu] 1.Print Density 2.Melody Sound 3.Paper Type 4.Hex Dump Mode 5.Wireless Type 6.WiFi Mode 7.IP Mode Select and then Enter... Enter : Press the feed button once for more than 1second. Select: Press the feed button many times less than 1second as menu number. Exit : Turn power off then on. Pressing FEED button for more than 1second, it is fixed(press enter), and less than 1 second, item is selected. For example, if you want to change the Wifi Mode of #6 menu, press #6 less than 1 second, and press more than 1 second. To exit, turn off the power and turn on again. 3) Successively, select from printed items and confirm. Ex) [Wireless Type] 1.WiFi -> 2.Bluetooth -> : Indicate current set status Select and then Enter... Ex) In here, arrow((->) indicates current settings. To change, select item and enter. TO move to Title HP-500 Ver 1 Rev. Page Ver1.0 P.7 next menu with no change, just enter without selecting item. 4) Successively, you will know the change result from the printed items. “ It was changed successfully!” This message means change was successful. “ The value is invalid, try again!” This message is shown when selected item is invalid or when you move to other menu without item change. 5) Setting result can be confirmed by printing test page or by the location of arrow(->) after selecting menu item in initial setting mode. 2-4) HEX Dump Setting up “Hex Dump Mode in Setting Mode. Then it prints all data in hex character (16 antilogarithm). You can see the status of receipt. . It will be useful for the appilcation you do. It prints the data, once it receives the data 12 digit. You can print the data less than 12 digit, when you press down the button of feed The control code ( 1F16 below) prints “.”. The 8016 above prints “^”. [Printing sample] 16 antilogarithm [HEX DUMP MODE] 41 42 43 44 45 46 47 47 49 30 31 32 33 34 35 36 37 38 FF 1B 69 ASCII A B C D E F G H I 0 1 2 3 4 5 6 7 8 ^ . i Title HP-500 Ver 1 Rev. Page Ver1.0 P.8 2-5) Onboard update Please conduct the updates, after refering the following steps. 1) Please switch off and on 2) Please check the connection between the printer and the data cable. * Please make sure about if it is the right cable. * If use USB cable, save the time to update the firmware 3) Please conduct the provided program , then set up the model and Interface port If the error LED is turned off and is lighted on slightly after 4 seconds, then the updated is being started. * Please do not switch off the printer power, till the update is complete. 4) The update will be complete, once the update indicates complete. * If the error LED keeps the light goes in and out, it’s error. Please stop the update program and make sure the cable and other connections. Please return the process “1.” and follow the step again. 5) Atfer update, automatically the printer will be reset for using and use the printer. Title HP-500 Ver 1 Rev. Page Ver1.0 P.9 2-6) Memory switch Please set the function of internal memory. ※ Please use the provided program - ‘memory swtich setting utility program’. ※ The value is not deleted until the next value is changed, even though power off. Memory SW Setting Value SW1 SW2 Reservation 0~1200 or 0~136 SW3 248-4000 SW4 SW5 Base Code Page Base Font SW6 Reservation SW7 Reservation SW8 Reservation Descreption Setting one default value for each country Setting one of 1) 2byte codes : korean(24 x 24), korean(16 x 16), Japenes(24x24), Chinese(24x24). 2).1byte codes : ASCII(12x24), ASCII(8x16,9x16) Setting paper Code Page Manu Font Manu After setting, Press the button Title HP-500 Ver 1 Rev. Page Ver1.0 P.10 [Memory Switch information] ================================ Code Page = PC437(U.S) 2Byte Font = Korean(24x24) 1Byte Font = ASCII(12x24) Mem1:FFh Mem2:FFh,FFh Mem3:FFh,FFh Mem4:00h Mem5:00h Mem6:FFh Mem7:FFh Mem8:FFh Mem9:FFh Mem10:FFh Mem11:40h Mem12:F9h (Ex) Sample of printing by selftest Title HP-500 Ver 1 Rev. Page Ver1.0 P.11 2-7) The way to connect the RF interface. 1) BlueTooth BlueTooth inteferface can be set up by simple control ① Please refer to 2-3P and set up from Wireless moder to Bluetooth ② When the Error LED is not lighting, Pressing power button and FEED button togather for 1second then take off. ③ And searching for Bluetooth device in Mobile Phone or PC ④ When finding “HWASUNG_XX:XX:XX” pairing automatically. on PC or Smart Phone and choosing it and it will be ⑤ the pairing is complete ordinarily, the light in LED bluetooth will be stopped. 2) WiFi There are two of modes Station Mode : Printer will be connected with Wireless directely.(SSID and others Setting necessary) AP Mode : Printer will be connected with other devices(Not setting necessary) ① Please refer to 2-3 and Set up “ Wireless Mode “ ② Please refer to 2-3 and Set up “ Station Mode “ or When choose “ AP Mode “ according to where you use. the mode is “AP Mode “ ③ Turn on the printer and atfer 3 second automatically IP Address and SSID and Password will be printed. ④ And please connect with PC or Smart Phone then put in the SSID and Password. ⑤ When the connection is complete, using IP address printed. Title HP-500 Ver 1 Rev. Page Ver1.0 P.12 3. General Specification 3-1) Specification 1) Printing : Direct thermal printer 2) Resolution and Dot : 203dpi, 1dot=0.125mm, 8dot/mm, Total 384 dot 3) Printing speed (Max) : 90mm/sec(Max) 4) Printing Width : 48mm 5) Paper Width : 58mm 6) Paper Diameter : 40 Diameter (Max) 7) Character (MAX) a line : 32fonts (ASCII 12 x 24),16fonts (Korean 24 x 24) 3-2) Font 1) English / Number 2) Graphic 3) International FONT A(8 x 24) 95, FONT B(8 x 16) 95 FONT A(8 x 24) 128, FONT B(8 x 20) 95 14types 37fonts (Korean,English,France,Germany,England,Denmark1,Swden,Italy, Spain1,Japan,Norway,Denmark2,Spain2,Latin America) 4) Korean FONT A Gothic (24 x 24), FONT B Gothic (16 x 16,option) 3-3) Internal Buffer Receiver buffer : 4KByte 3-4) Electrical Spec 1) Operating Voltage Insert Voltage Operation voltage Logic voltage 7.4V Li-ion Battery 5V 5V±5% Motor,Thermal print head Logic circuit 2) Consumption current Average : 1.5A(Printing percentage 12.5%)) Peak : 3.7A 3-5) Operation condition (temperature / Humid) 1) Temperature : 0∼40℃ 2) Humidity : 40∼90%RH(in not dew condensation) Notice : The printing is subjet to the operation condition. 3-6) MCBF 1) Mechanism : 15,000,000 Lines. 2) Thermal Print Head 50Km, 1 pulse. Title HP-500 Ver 1 Rev. Page Ver1.0 P.13 4. Interface specification 4-1) RS-232C 1) Data Transmission : Serial 2) Hand shake : Hardware (RTS/CTS or DTR/DSR ) 3) Baud Rate : 9600, 19200, 38400, 57600 BPS 4) Data Bit : 8bit 5) Parity : None, Odd, Even 6) Stop Bit : 1 or 1.5 or 2 bit 7) Connector : 10 pin Mini-B(Dedicated Cable) Pin Printer Signal TxD RxD DTR/RTS GND Pin In/Out Out In In Host Signal RxD TxD CTS GND DSR In/Out In Out In In (Dotted line) : Connect to host. 4-2) USB 1) Standard : USB 2.0 Compatibility, Full Speed(12Mb) 2) Connector : Type MINI-B 3) Cable : USB2.0 Standard Cable 4) Data : Bulk IN, Bulk OUT Bulk IN : End point 6 Bulk OUT : End point 2 Full Speed : Max Packet Size 64 Byte(Bulk OUT),64 Byte(Bulk IN) 4-3) WiFi 1) Standard : IEEE 802.11b/g/n, 2) Frequency : 2.400 GHz ~ 2.484 GHz 3) Channel : CH1 ~ CH11 4) Security : WEP, WPA/WPA2PSK 4-4) BlueTooth 1) Standard : Bluetooth 3.0 Class2 Title HP-500 Ver 1 Rev. Page Ver1.0 P.14 5.Commend Command CR LF CAN HT FF SUB x SUB p SUB R SUB B SUB 1 SUB 2 SUB W SUB C SUB O SUB F SUB P ESC D ESC SP ESC ! ESC $ ESC * ESC ESC 2 ESC 3 ESC @ ESC E ESC G ESC J ESC j ESC M ESC R ESC a ESC d ESC { ESC t ESC S ESC L ESC FF Function Print and carriage return Print and line feed Cancel the print data Horizontal tab Print the page mode / return to the standard mode Extended graphic mode Print the off line a paper detection Outline Character (Tetragon) 2D barcode Line 1 (Vertical, Horizontal) Line 2 (Vertical, Horiztontal) Write (line data) Clear (line data) Line ON Line OFF Print line 1 dot line (Vertical, Horizontal) Horizontal tab position Spacing the character of ASCII Font decoration Absolute position of printing Bit image (vertical) Underline the character of ASCII Initial row pitch Row pitch Printer reset Emphasize Double FEED BACK FEED Font (ASCII) International character Align the printing Printing and row FEED 180° rotation Code page (International) Standard mode / Clear the area of page Page mode Printing of page area Title HP-500 Ver 1 PAGE 17 17 17 17 17 18 18 18 18 19 19 19 19 20 20 20 20 20 21 21 21 23 23 24 24 24 24 24 24 25 25 26 26 26 26 27 27 27 Rev. Page Ver1.0 P.15 Command ESC T ESC W FS ! FS & FS . FS FS S FS W FS q FS p GS ! GS (K (fn=49) GS (K (fn=97) GS B GS H GS L GS W GS h GS k GS w GS r GS a GS v DLE ENQ DLE EOT Function Page mode (Direction of printing) Page mode (Area of printing) Korean font decoration Korean extended graphic mode (set up) Korean extended graphic mode (cancel) Underline Korean Space Korean Size Korean Register Non Volatile logo (bit image) Non Volatile logo print Extension of character Density of printing Operating Thermal Head Partially Reverse printing in black / white Barcode Left space Area of printing Barcode (Height) Barcode (Printing) Barcode (Extension / Reduction) Status check Status check (Auto reply) Laster bit image (Horizontal) Buffer clear (real time) Status transmission (real time) Title HP-500 Ver 1 PAGE 28 29 30 30 30 31 31 31 32 32 33 33 34 34 34 35 35 35 35 36 37 37 38 38 39 Rev. Page Ver1.0 P.16 CR [Name] [Format] [Range] [Descript] LF [Name] [Format] [Range] [Descript] [Caution] CAN [Name] [Format] [Range] [Dsecirpt] HT [Name] [Format] [Range] [Descript] [Caution] FF [Name] [Format] [Range] [Descript] [Caution] Print and carriage return ASCII CR Hex 0Dh Decimal 13 equal LF Print and line feed ASCII LF Hex 0Ah Decimal 10 ① STANDARD MODE: After printing the data and go to return according as the fixed data. ② PAGE MODE: The fixed data can be only conduted, according as the fixed data. The LF is ignored behind of CR Cancel print data in page mode ASCII CAN Hex 18h Decimal 24 The data is deleted within the area of printing. Horizontal tab ASCII HT Hex 09h Decimal Moves the print position to the next tab poisition Horizontal tab position are to set in ESC+’D’+n. Print and return to standard mode in page mode ASCII FF Hex 0Ch Decimal 12 Print the data in the print buffer and returns to standard mode Use the command ESC+FF , in order not to return the standard mode. The data is not deleted in the area of page. Title HP-500 Ver 1 Rev. Page Ver1.0 P.17 SUB+’x’+n [Name] [Format] Hex Decimal [Range] [Initial Value] [Descript] SUB+’p’+n [Name] [Format] [Range] [Initial Value] [Descript] SUB+’R’+n [Name] [Format] [Range] [Descript] [Caution] Extension Graphic Mode, Korean Mode ASCII SUB 1A 78h 26 120 0≤n≤1 n=0 n=0 : Korean Mode, First code is A1h more, automatically transfer Korean in 2 bytes n=1 : Extension Graphic Mode, Every code is setting in 1 byte Extension Graphic font will be printed Off line printing in paper detection ASCII SUB Hex 1A 70h Decimal 26 112 0≤n≤1 n=1 n=0 : Not transition to offline once paper empty (data communication available) n=1 : Transition to offline once paper empty (data communication not avaiable) Set the character outline ASCII SUB Hex 1A 52h Decimal 26 82 0≤n≤1 n=0 : cancel character outline (tetragon) n=1 : Set character outline (tetragon). The horizontal extension is valid as eight times. The vertical extension is valid as two times SUB+’B’+n1+n2+n3+d1……dk [Name] [Format] [Range] [Descript] 2D Barcode. ASCII SUB n1 n2 n3 Hex 1A 42h n1 n2 n3 Decimal 26 66 n1 n2 n3 Please refer the table below. Please choose the barcode by the data of barcode. d1…………dk d1…………dk d1…………dk n1 : two dimension of barcode n2 : the number of data of barcode n3 : size of barcode d1… dk : the data of barccode n1 Barcode PDF417 QR code Title HP-500 Ver 1 Rev. Page Ver1.0 P.18 1) PDF417 n2 n3 2) QR code n2 n3=1 n3=3 n3=5 n3=9 Number of data 1 < n2 ≤ 255 Size of data Horizontal 3 Horizontal 4 Horizontal 5 Horizontal 6 Horizontal 7 Horizontal 8 Horizontal 9 n3 Number of data 1 < n2 ≤ 17 1 < n2 ≤ 53 1 < n2 ≤ 106 1 < n2 ≤ 230 Size of data Version 1 Version 3 Version 5 Version 9 ※ Vertical is set autom atically. SUB+’1’ [Name] [Format] [Description] SUB+’2’ [Name] [Format] [Description] Line 1 (Vertical, Horizontal) ASCII SUB Hex 1A 31h Decimal 26 49 Line of Vertical Horizontal. Line 2 (Vertical,Horizontal) ASCII SUB Hex 1A 32h Decimal 26 50 Line of Vertical Horizontal SUB+’W’+nL+nH+kL+kH [Name] Write (line data) [Format] ASCII SUB nL nH kL Hex 1A 57h nL nH kL Decimal 26 87 nL nH kL [Range] 0≤nL+(nH×256)≤512、(0≤nL≤255, 0≤nH≤3) 0≤kL+(kH×256)≤512、(0≤kL≤255, 0≤kH≤3) [Description] It writes 1 from nL+nH×256 to kL+kH×256. [Caution] It is not deleted, till you power off, or you clear the command. SUB+’C’ [Name] [Format] [Description] [Caution] kH kH kH Clear (line data) ASCII SUB Hex 1A 43h Decimal 26 67 It clears all of line zero (0). Please use this command to write the line again. Please use the command line ON/ line OFF to write line 1 to speed up the progress. Title HP-500 Ver 1 Rev. Page Ver1.0 P.19 SUB+’O’ [Name] [Format] [Description] SUB+’F’ [Name] [Format] [Description] SUB+’P’ [Name] [Format] [Description] [Caution] Line ON ASCII SUB Hex 1A 4Fh Decimal 26 79 The line data is valid ON. The line prints together, when you print the character. Line OFF ASCII SUB Hex 1A 46h Decimal 26 70 The line is valid OFF. The line data is preserved. Print line 1 dot line (Vertical,Horizontal) ASCII SUB Hex 1A 50h Decimal 26 80 It prints line 1 dot line. Please do not use this command, when you print any character,or any graphic. Please use the command Line ON. Please use this command, when you print the line at the space. ESC+’D’+n1…nk+NUL [Name] Set the horizontal position [Format] ASCII ESC n1…nk NUL Hex 1B 44h n1…nk 00 Decimal 27 68 n1…nk 0 [Range] 1≤n≤255, 0≤k≤32 [Descript] Set the horizontal tab position [Caution] n : Indicating the figures from the start poistion of line to set position K : indicating the total tabs a line ESC+SP+n [Name] [Format] [Range] [Initial Value] [Descript] [Caution] Set the space amount on the right of ASCII character ASCII ESC SP Hex 1B 20h Decimal 27 32 0≤n≤255 n=0 Set in n x 0.125mm the space amount on the right of ASCII character Set the Korean space in FS+’S+n Title HP-500 Ver 1 Rev. Page Ver1.0 P.20 ESC+’!’+n [Name] [Format] Font decoration ASCII ESC Hex 1B 21h Decimal 27 33 0≤n≤255 n=0 It sets the font decoration in the same time. [Range] [Initial] [Description] Bit Function 0: Font 12x24, 24x24 1: Font 8x16, 16x16 0: Cancel the highlight 1: Set the highlight 0: Cancel the extension in Vertical 1: Set the extension in Vertical 0: Cancel the extension in Horizontal 1: Set the extension in Horizontal 0: Cancel the underline 1: Set the underline ESC+’$’+nL+nH [Name] [Format] [Range] [Initial Value] [Descript] Hex 00h 01h 00h 08h 00h 10h 00h 20h 00h 80h Decimal 16 32 128 Set absolute poisition ASCII ESC nL nH Hex 1B 24h nL nH Decimal 27 36 nL nH 0≤nL+nH×256≤65535, 0≤nL≤255, 0≤nH≤255 nL=0, nH=0 Move the printing position from left ending space to (nL+nH×256)×0.125mm Move the printing position in left ending once printing position is over. ESC+’*’+m+nL+nH+d1+…+dk [Name] Set the bitmap image [Format] ASCII ESC nL Hex 1B 2Ah nL Decimal 27 42 nL [Range] m=0,1,32,33 1≤nL+nH×256≤1023, 0≤nL≤255, 0≤nH≤3, 0≤d≤255 [Descirpt] nH nH nH d1…dk d1…dk d1…dk Due to fixing nL+nHx256, Printing from bit data to graphic data in Mode m Title HP-500 Ver 1 Rev. Page Ver1.0 P.21 m Mode 8dots Single Density Dots in Dots in vertical horizontal 224 Data (k) nL+nH×256 8dots Double Density 448 nL+nH×256 32 24dots Single Density 24 224 (nL+nH×256)×3 33 24dots Double Density 24 448 (nL+nH×256)×3 •8 dots Mode D1 D2 Twice D3 once MSB LSB D1 D2 D3 Single Title HP-500 Ver 1 Double Rev. Page Ver1.0 P.22 •24 dots Mode Twice D1 D2 D3 D4 D5 D6 D7 D8 D9 Once MSB Once Once LSB D1 D4 D7 D2 D5 D8 D3 D6 D9 Single Density ESC+’-’+n [Name] [Format] Set / Cancel underline ASCII ESC Hex 1B Decimal 27 [Range] 0≤n≤255, [Invitial Value] n=0, [Descript] Set / Cancel underline Function Cancel underline Set underline in thick 0.125mm Set underline in thick 0.25mm Set underline in thick 0.375mm Set underline in thick 0.5mm Set underline in thick 0.625mm Set underline in thick 0.75mm Set underline in thick 0.875mm ESC+’2’ [Name] [Format] [Range] [Initial Value] [Descirpt] 2Dh 45 Double Density Set the interval of initial line ASCII ESC Hex 1B 32h Decimal 27 50 0≤n≤255, n=0 Set the interval of initial value in 4mm Title HP-500 Ver 1 Rev. Page Ver1.0 P.23 ESC+’3’+n [Name] [Format] [Range] [Initial Value] [Descript] ESC+’@’ [Name] [Format] [Range] [Descript] ESC+’E’+n [Name] [Format] [Range] [Initial Value] [Descript] ESC+’G’+n Name] [Format] [Range] [Initial Value] [Descript] ESC+’J’+n [Name] [Format] [Range] [Descript] ESC+’j’+n [Name] [Format] [Range] [Descript] Set the interval of line ASCII ESC Hex 1B 33h Decimal 27 51 0≤n≤255, n=0 Set the interval of line in n x 0.125mm Rest printer ASCII ESC Hex 1B 40h Decimal 27 64 0≤n≤255, Clear buffer & Initialize all parameter Set the font in thick ASCII ESC Hex 1B 45h Decimal 27 69 0≤n≤255, n=0 n=0, cancel the font in thick n=1, set the font in thick Set the printing double for font thickness ASCII ESC Hex 1B 47h Decimal 27 71 0≤n≤255, n=0. n=0. cancel the printing twice for font thickness. n=1. set the printing twice for font thickeness. Feeding ASCII ESC Hex 1B 4Ah Decimal 27 74 0≤n≤255 Printing the data inner buffer, feeding in n x 0.125mm Back Feeding ASCII ESC Hex 1B 6Ah Decimal 27 106 0≤n≤255 Printing the data inner buffer and back feeding in n x 0.125mm Title HP-500 Ver 1 Rev. Page Ver1.0 P.24 ESC+’M’+n [Name] [Format] [Range] [Initial Value] [Descript] Select font ASCII ESC Hex 1B Decimal 27 0≤n≤2 n=0 Select printer font 4Dh 77 Precedence 4bits(Korean fonts) 0000 Korean 24x24 Gothic 0001 Korean 16 x 16 General 0010 Japanese 24 x 24 Bodoni 0011 Chinese 24 x 24 Gothic 0000 0001 0010 0011 Subordinate 4bits (ASCII) Korean 24x24 Gothic Korean 16 x 16 General Japanese 24 x 24 Bodoni Chinese 24 x 24 Gothic Notice : When you set up one of fonts, you can use “Memory Switch Setting program “ without commend. If you need any more information, please refer to How to use Memory Switch Setting Program. * Caution : In case of Big Font as 56x88, it would be possible to extend font size as much as Double(Width and Length) and other fonts would be possible to extend the font size as Octuple ESC+’R’+n [Name] [Format] Select the International character ASCII ESC Hex 1B 52h Decimal 27 82 0≤n≤13 n=13 Select the international character as follows:- [Range] [Initial Value] [Descirpt] 10 11 12 13 Country Name USA France Germany England Denmark1 Sweden Italian Spain1 Japanese Norway Denmark2 Spain2 Latin America Korea Title HP-500 Ver 1 Rev. Page Ver1.0 P.25 ESC+’a’+n [Name] [Format] [Range] [Initial Value] [Descript] Align the printing ASCII ESC Hex 1B 61h Decimal 27 97 0≤n≤2 n=0 Align the printing position ESC+’d’+n [Name] [Format] [Range] [Descript] ESC+’{’+n [Name] [Format] [Range] [Initial Value] [Descript] [Caution] [Range] [Initial Value] [Descript] [Caution] Printing Position Left Middle Right Printing and feeding ‘n’ line ASCII ESC Hex 1B 64h Decimal 27 100 0≤n≤255 Printing the date & feeding ‘n’ line Turning 180° ASCII ESC Hex 1B 7Bh Decimal 27 123 0≤n≤255 n=0 Set the reverse image Move the standard from the left to the right ESC+’t’+n [Name] [Format] Function Cancel 180° Set 180° International code page ASCII ESC t Hex 1B 74h Decimal 27 116 0≤n≤5 14≤n≤17 n=0 You can see the following table of the international code page. It is valid, if you direct the command SUB+”x” for 1 byte. It is not valid, if you direct the command SUB+”x” for 2 bytes. Title HP-500 Ver 1 Rev. Page Ver1.0 P.26 n ESC+’S’ [Name] [Format] [Descript] 10 code page PC850((Multilingual) PC860(Portugal) Windows1252 Iran System Encoding Standard PC857(Turkish) Set the Standard mode ASCII ESC Hex 1B 53h Decimal 27 83 Swtiches from page mode to standard mode and the data is deleted at the page. ESC+’L’ [Name] [Format] [Range] [Initial Value] [Descript] ESC+FF [Name] [Format] ASCII [Descript] code page PC437(US) KANA(JAPAN) GREEK Windows1251 PC866(Cyrllic #2) Windows1250 (Poland) Select page mode ASCII ESC Hex 1B 4Ch Decimal 27 76 0≤n≤255 n=0 Switches from standard mode to page mode Printing as the page mode ESC FF Hex 1B 0Ch Decimal 27 12 It prints the data at the page mode. (The data is NOT deleted at the page.) Title HP-500 Ver 1 Rev. Page Ver1.0 P.27 ESC+’T’+n [Name] [Format] [Range] [Initial Value] [Descript] Select print direction in page mode ASCII ESC Hex 1B 54h Decimal 27 84 0≤n≤3 n=0 Select the print direction & start position in page mode •n=0(Left→Right), •n=1(Bottom→Top), ABCD Feeding ABCD Feeding •n=2(Right→Left), •n=3(Top→Bottom), ABCD Feeding Feeding ABCD Title HP-500 Ver 1 Rev. Page Ver1.0 P.28 ESC+’W’+xL+xH+yL+yH+dxL+dxH+dyL+dyH [Name] Set printing area in page mode [Format ] ASCII ESC W xL xH yL yH dxL dxH dyL dyH Hex 1B 57h xL xH yL yH dxL dxH dyL dyH Decimal 27 87 xL xH yL yH dxL dxH dyL dyH [Range] [Initial Value] [Descript] [Caution] 0≤xL+xH×256≤65535 (0≤xL≤255, 0≤xL≤255) 0≤yL+yH×256≤65535 (0≤yL≤255, 0≤yL≤255) 1≤dxL+dxH×256≤65535 (0≤dxL≤255, 0≤dxL≤255) 1≤dyL+dyH×256≤65535 (0≤dyL≤255, 0≤dyL≤255) (xL+xH×256)=0 (0mm, xL=0, xH=0) (yL+yH×256)=0 (0mm, yL=0, yH=0) (dxL+dxH×256)=448 (56mm, dxL=C0h, dxH=01h) (dyL+dyH×256)=1200 (150mm, dyL=B0h, dyH=04h) Set printing area & starting point Horizontal starting point : (xL+xH×256) × 0.125mm Vertical starting point : (yL+yH×256) × 0.125mm Horizontal size : (dxL+dxH×256) × 0.125mm Vertical size : (dyL+dyH×256) × 0.125mm The maximum page width is available 56mm The maximum page length is available 150mm Barcode & graphic data is executed as per standard line, If the size exceed the standard line, move the standardline by CR or LF. : Barcode or Graphic Paper (x,y) ABCD dx Paper EFGH Standard Move the standard line by CR or LF Printing Area dy Printing before moving the standard line EFGH (x+dx,y+dy) Printing after ABCD moving the standard line Title HP-500 Ver 1 Rev. Page Ver1.0 P.29 FS+’!’+n [Name] [Format] [Range] [Initial Value] [Descript] [Caution] Bit Set the printing mode in Korean ASCII FS Hex 1C 21h Decimal 28 33 0≤n≤255 n=0 Set the printing mode in Korean Only valid in Koean Function Cancel the horizontal extension Hex 00h 00h 00h Decimal Set the horizontal extension Cancel the vertical extension 04h 00h Set the vertical extension Cancel the underline Set the underline 08h 00h 00h 00h 00h 80h 128 FS+’&’ [Name] [Format] [Descript] [Caution] FS+’.’ [Name] [Format] [Descript] [Caution] Set to print Korean mode (2bytes Mode) ASCII FS Hex 1C 26h Decimal 28 38 Set to print Korean mode (2bytes Mode) Set to print Korean mode in extended graphic mode Appointment is not required in Korean mode, due to auto detection. (Ref.SUB+’x’+n command) Cancel Korean mode (2Bytes mode) ASCII FS Hex 1C 2Eh Decimal 28 46 Cancel Korean mode (2Bytes mode) In case of cancel 2 bytes mode in extended graphic mode Appointment is not required due to auto detection in Korean mode (Ref.SUB+’x’+n command) Title HP-500 Ver 1 Rev. Page Ver1.0 P.30 FS+’-’+n [Name] [Format] Set the underline of Korean ASCII FS Hex 1C 2Dh Decimal 28 45 0≤n≤2 n=0 Set the underline of Korea [Range] [Initial Value] [Descript] Function Cancel the underline of Korean Set the thickness of underline in 0.125mm Set the thickness of underline in 0.25mm FS+’S’+n1+n2 [Name] [Format] [Range] [Initial Value] [Descript] FS+’W’+n [Name] [Format] [Range] [Initial Value] [Descript] Set the space between Korean characters ASCII FS n1 Hex 1C 53h n1 Decimal 28 83 n1 0≤n1≤255, 0≤n2≤255 n=0 Set the space between Korean characters Set the left space in n1×0.125mm Set the right space in n2×0.125mm n2 n2 n2 Set the font size in Korean ASCII FS Hex 1C 57h Decimal 28 87 0≤n1≤255 n=0 Set the Korean font size twice (HorizontalxVertical) in Korean n=0, Cancel the font size two times n=1, Set the font size two times Title HP-500 Ver 1 Rev. Page Ver1.0 P.31 FS+’q’+n+(xL+xH+yL+yH+d1…dk)1……+(xL+xH+yL+yH+d1…dk)n [Name] Register logo (bitmap image) non volatilization [Format] ASCII FS n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n Hex 1C 71h n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n Decimal 28 113 n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n [Range] 1≤n≤255 0≤xL+xH×256≤65535 (0≤xL≤255, 0≤xH≤255) 0≤yL+yH×256≤65535 (0≤yL≤255, 0≤yH≤255) 0≤d≤255 k=(xL+xH×256)×(yL+yH×256)×8, Capable register : 64kbytes [Descript.] [Caution] Register the logo non-volatilization n : Total unit of N/V logo xL,xH : Set the horizontal dot in (xL+xH×256)×8 yL,yH : Set the vertical dot in (xL+xH×256)×8 k : Bitmap image of a N/V logo Register various as much as NV’s capa. Required to delete all if (it is) registered again. Renewable registeration / deletion at 100000 cycles, It’s not recommended frequent registeration / deletion, due to memory damageD1 D(x×8-1)×y+1 . . . . . . . . . Dy D(x×8)×y FS+’p’+n+m [Name] [Format] Printing N/ V logo ASCII FS Hex 1C 70h Decimal 28 112 1≤n≤255, 0≤m≤3 n=0 m : printing the registered N/V in ‘m’ mode n : indicating the regsitered logo in the ‘n’. [Range] [Initial Value] [Descript.] MSB LSB Printing mode Standard Horizontal extension Vertical extension Horizontal,vertical extension in the same time Title HP-500 Ver 1 Rev. Page Ver1.0 P.32 GS+’!’+n [Name] [Format] [Range] [Initial Value] [Descript.] [Caution] Set the proportion of character extention ASCII GS Hex 1D 21h Decimal 29 33 0≤n1≤255 (horizontal / vertical portions is restricted maxim value 8) n=0 Set the proportion of character extention Caculate the numberic value, if vertical & horizontal is extended in the same time ex.) x3 (Horizontal Rate), x3(Vertical Rate) : n=32+2=34 Bit 0-3 Set the extension proportion in vertical Function 4-7 Set the extension proportion in horizontal Extension in Horizontal n(Hex) n(Decimal) 00h 10h 16 20h 32 30h 48 40h 64 50h 80 60h 96 70h 112 Rate x1 x2 x3 x4 x5 x6 x7 X8 Extension in Vertica n(Hex) n(DecimaL) Rate 00h x1 01h x2 02h x3 03h x4 04h x5 05h x6 06h x7 07h X8 GS+’(’+’K’+pL+pH+fn+m (fn=49) [Name] Set the printing density [Format] ASCII GS pL pH fn Hex 1D 28h 4Bh pL pH Decimal 29 40 75 pL pH [Range] pL=2, pH=0, fn=49 1≤m≤30 [Initial Value] It set up automatically as per the voltage. (Ref.Table below) [Descript] Set the printing density Drive Voltage (Vp) 5 ~ 5.4V 5.5 ~ 5.9V 6 ~ 6.4V 6.5 ~ 6.9V 7.0 ~ 7.4V 7.5 ~ 7.9V 8.0 ~ 8.3V 8.4V ~ 8.5V fn fn 26 16 10 ※ Once it is a power on reset, the density is set up automatically, You can choose the density as per the conditions, such as power,printing quality. Title HP-500 Ver 1 Rev. Page Ver1.0 P.33 GS+’(’+’K’+pL+pH+fn+m (fn=97) [Name] Operating thermal head partially [Format] ASCII GS pL pH fn Hex 1D 28h 4Bh pL pH fn Decimal 29 40 75 pL pH fn [Range] pL=2, pH=0, fn=97 0≤m≤4 [Initial Value] m=2 (3 partiation) [Descript] Set the operation of partial thermal head [Caution] This function is effective in case of power capa is short. The current electric will be reduced as big as the partition. GS+’B’+n [Name] [Format] [Range] [Initial Value] [Descript] GS+’H’+n [Name] [Format] [Range] [Initial Value] [Descript] Thermal Head Partition operation First Partition Second Partition Third Partition Fourth Partition Fifth Partition Reverse printing in black ASCII GS Hex 1D 42h Decimal 29 66 0≤n≤255 n=0 Reverse printing in black n=0, standard printing n=1, reverse printing in black Select the printing position of HRI characters (Barcode) ASCII GS Hex 1D 48h Decimal 29 72 0≤n≤3 n=0 Select the printing positions of numerical value & characters Printing Position Non printing Above the barcode Below the barcode Both above & below barcode Title HP-500 Ver 1 Rev. Page Ver1.0 P.34 GS+’L’+nL+nH [Name] [Format] [Range] [Initial Value] [Descript] GS+’W’+nL+nH [Name] [Format] [Range] [Initial Value] [Descript] Select the left margin ASCII GS nL nH Hex 1D 4Ch nL nH Decimal 29 76 nL nH 0≤nL≤255, 0≤nH≤255 nL+nH×256=0 (nL=0, nH=0) The left margin is set in (nL+nH×256)×0.125mm. Set printing area width ASCII GS nL nH Hex 1D 57h nL nH Decimal 29 87 nL nH 0≤nL≤255, 0≤nH≤255 nL+nH×256=448 (56mm, nL=0, nH=0) Set printing area width from the left margin in (nL+nH×256)×0.125mm Printing area Left Margin GS+’h’+n [Name] [Format] [Range] [Initial Value] [Descript] Printing area width Select barcode height ASCII GS Hex 1D 68h Decimal 29 104 1≤n≤255 n=162 (20.25mm) Select barcode height by n×0.125mm GS+’k’+m+d1…dn+NUL [Name] [Format] [Range] [Descript] Print barcode ASCII GS d1…dn NUL Hex 1D 6Bh d1…dn 00h Decimal 29 107 d1…dn 0 1≤m≤7, n & d depend on barcode system used Refer the table as below Title HP-500 Ver 1 Rev. Page Ver1.0 P.35 m Barcode system (Barcode data numbers) d (barcode data ) UPC-E n=7 (check digit is automatically added ) 48≤d≤57 EAN13 n=12 (check digit is automatically added) 48≤d≤57 EAN8 n=7 (check digit is automatically added) 48≤d≤57 CODE39 1≤n (Start & Stop characteres is automatically 48≤d≤57, 65≤d≤90 added d=32,36,37,43,45,46,47 48≤d≤57 ITF(I of 2/5) 1≤n CODABAR 1≤n (Only even number) 48≤d≤57, 65≤d≤68 d=36,43,45,46,47,58 2≤n≤255 (Check digit , Stop character CODE128 0≤d≤127 Is automatically added) [Caution] In CODE128, set additional “{“ in 2bytes when the special character as below Special character SHIFT CODE A CODE B CODE C FNC1 FNC2 FNC3 FNC4 “{“ ASCII {S {A {B {C {1 {2 {3 {4 {{ Barcode data Hex 7Bh, 53h 7Bh, 41h 7Bh, 42h 7Bh, 43h 7Bh, 31h 7Bh, 32h 7Bh, 33h 7Bh, 34h 7Bh, 7Bh Decimal 123, 83 123, 65 123, 66 123, 67 123, 49 123, 50 123, 51 123, 52 123, 123 GS+’w’+n [Name] [Format] [Range] [Initial Value] [Descript.] Set the vertical size of barcode ASCII GS Hex 1D 77h Decimal 29 119 1≤n≤4 n=2 Set the horizontal size of barcode Module barcode width 0.25mm 0.375mm 0.5mm 0.625mm Two level barcode Narrow Wide 0.125mm 0.375mm 0.25mm 0.625mm 0.375mm 1mm 0.5mm 1.25mm * Multi Level barcode : UPC-E, EAN13, EAN8 * 2 level barcode : CODE39, ITF, CODABAR Title HP-500 Ver 1 Rev. Page Ver1.0 P.36 GS+’r’+n [Name] [Format] Transmit status ASCII GS Hex 1D 72h Decimal 29 114 n=1 Transmit current status of printer The status is not ready till the printer is offline, The command is executed when the data in receive buffer is devloped Therefore automatic status function (GS+’a’+n) is to use better, It is used for re-confirm in on-line after automatic status is received [Range] [Descript] [Caution] GS+’a’+n [Name] [Format] Enable / Disable automatic status back (ASB) ASCII GS Hex 1D 61h Decimal 29 97 0≤n≤1 n=1 Enable / Disable ASB If the status is changed after checking the printer status, the status is automatically executed. This command is executed to enable or disable. [Range] [Initial Value] [Descript] Function Disable automatic status back Enable automatic status back Bit 0 : Paper 1 : No paper 0 : Printer head down 1 : Printer head up 0 : Paper w/o jamm 1 : Paper with jamm 0 : Paper enough 1 : Paper Near End 0 : Print complete 1 : Print or Feeding Hex 00h 01h 00h 02h 00h 04h 00h 08h 00h 10h 00h Decimal 16 00h 00h Satus ※ the status of bit 4 is effective when the realtim e conducts the command DLE + EOT + n, The others are fixed ‘0’. Title HP-500 Ver 1 Rev. Page Ver1.0 P.37 GS+’v’+’0’+m+xL+xH+yL+yH+d1+…+dk [Name] [Format] Laster bit image ASCII GS xL xH yL yH d1..dk Hex 1D 76h 30h xL xH yL yH d1..dk Decimal 28 118 48 xL xH yL yH d1..dk 0≤m≤3 or 48≤m≤51, 1≤(xL+xH×256)≤150 (0≤xL≤150, xH=0) 1≤(yL+yH×256)≤436 (0≤yL≤255, 0≤yH≤1) 0≤d≤255 (yL+yH×256) K (All data) = (xL+xH×256) × (yL+yH×256) The laster bit image will be recognized in mode ‘m’. xL,xH appoint the data (byte) of horizontal at image data. yL,yH appoint the dta (dot line) of vertical at image data. [Range] [Descript] * d is a data for laster bit. 0, 48 1, 49 2, 50 3, 51 Mode Normal Horizontal expansion Vertical expansion Horizontal,Vertical expansion Expansion x1 x2 x2 x2 (Horizontal & Vertical) Ex) Expansion image xL+xH×256 = 32 byte, 32 × 8 = 256 dot 33 34 35 …… …… k-31 k-30 30 31 32 …… 62 63 64 …… …… …… …… …… k-29 …… k-2 k-1 7 6 MSB …… yL+yH×256 dot line 1 0 LSB DLE+ENQ+n [Name] Realtime request the printer to be clear each buffer [Format] ASCII DLE ENQ Hex 10h 05h Decimal 16 [Range] n=2 [Descript] The realtime clear each buffer as soon as this command receive. [Caution] It’s only valid as you switch up ‘1’ as ‘ON’. This command is only effective if the printer is off. This command is only effective if it receives the data as same command. This command is not effective if it’s online. Title HP-500 Ver 1 Rev. Page Ver1.0 P.38 DLE+EOT+n [Name] [Format] [Range] [Descript] [Caution] Realtime status transmission ASCII DLE EOT Hex 10h 04h Decimal 16 n=2 The real time transmits a byte as soon as this command receives. It’s only valid as you switch up ‘1’as ‘ON’. Please refer status table at the page 29. If the command is received same data, it could be same operation (Bit image data,etc) Title HP-500 Ver 1 Rev. Page Ver1.0 P.39 6. Widows Driver 6-1) Set up the function. 1) Please open the screen of printer / fax, and click the basic setting (I) of the general tap. 2) Please click (V). 3) Please refer to the following images, and set up each details. 6-2) Set up the paper. Please set the form feeding after printing. 1) Please click the basic setting (I) of the general tap. 2) Please click the tap of paper /quality, and drop down paper providing. 3) Auto & Role Feeder : After printing, the form feeding is not conducted any more. Please set up if the printing length is not regular. You can’t conduct the feeding, even you set up the space at the program Visual Basic. We recommend you make the font size smaller, such as “.”, and make the position the cutting. Example) '----- Example Dummy form feeding to cutting position --------Printer.Print " " & vbLf Printer.Print " " & vbLf Printer.Print " " & vbLf Printer.FontSize = 2 Printer.Print "." Printer.EndDoc ' dummy print for form feeding 4) Page length Feeder : After printing, The form feeding will be conducted as long as the length is fixed. It is mostly used when the regular legnth is printed. 6-3) Set up the new paper. You can make the size of paper you need. Please refer the example of 60mm x 150mm as below. 1) Please open the screen of printer & fax,and click the server on file / menu. 2) Please choose the STANDARD(Size 80 x 400mm) as image. 3) Please tick ‘new documentation (C)’ as image. 4) Please type the width 6.0 cm / the height 15.0 cm as image. 5) Please click the ‘form install’ Ticket (Size 60 x 150mm) as image. 6) Please click the tap ‘advanced’ and set the paper Ticket(Size 60 x 150mm). Title HP-500 Ver 1 Rev. Page Ver1.0 P.40 . USB (User Interface) Without using the Windows driver, you are able to check the printer status, and transmit / receive the data, by using USB Interface DLL (HwaUSB.DLL) and OCX driver (HwaUSB.OCX). 7-1) DLL Interface Please add the file HwaUSB.DLL at the folder System 32, or the folder SysWow64. 7-1-1) DLL function. 1) long UsbOpen(LPCTSTR SelPrinter); Please open the port USB by the printer Model “HP-500” Parameters: SelPrinter : Printer Model Name Return : Open normal : 0 Open error : -3(minus) 2) long PrintStr(LPCTSTR data); It prints the string. Parameters: data : String datas Return : Print normal : 1 Print error : 0 Notice : To prevent the loss of data for the print timeout , Please use the function ‘NewRealRead’ to check the status,and go to the next step, when it’s normal. 3) long PrintCmd(unsigned char data); It prints the data one (1) byte. Please use the ‘PrintPackage function’ as below, if there are a lot of datas to print. Then you are able to increase the speed of the transmission. Parameters: data : one (1) byte data (0~255) Return : Print normal : 1 Print error : 0 Title HP-500 Ver 1 Rev. Page Ver1.0 P.41 4)long NewRealRead(void); It reads the printer status data as one (1) byte by the port USB. Parameters: None Return : Read normal : Printer status value. Read error : -1( minus ) 5)long PrintPacket(unsigned char *PacketBuf,unsigned long PacketLength); It prints the data by the port USB, as much as the data at the transmission data buffer . Parameters: PacketBuf : Transmission data buffer pointer. PacketLength : Transmissiong data length Notice : Please do not exceed more than 64 bytes max. Return : Print normal : 1 Print error :0 Notice Please do not use any function we don’t provide, due to the debug usage. Notice Please ask the sample program for more details. Title HP-500 Ver 1 Rev. Page Ver1.0 P.42 7-2) Caution for using USB Interface If you use the USB interface and windows drivers together, the data will not be printed in regular sequence. So please release the spool, when you wan to use the USB interface and window driver together. If you release the spool, the data receipt is only made by USB Interface. ※ The Data diafram of window application. Window Application Window Driver (Graphic) USB Port Printer DLL Interface OCX Driver (Command, Character) Send Receive (Printer State Date) Title HP-500 Ver 1 Rev. Page Ver1.0 P.43 No. Date 2017.05.02 Descripction Page Release HP-500 V1.0 Title HP-500 Ver 1 Ver. V1.0 Rev. Page Ver1.0 P.44 FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. Title HP-500 Ver 1 Rev. Page Ver1.0 P.45
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : KCS Create Date : 2017:08:08 16:18:17+09:00 Modify Date : 2017:08:08 16:18:32+09:00 Subject : Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2017:08:08 16:18:32+09:00 Creator Tool : Word용 Acrobat PDFMaker 11 Document ID : uuid:93c48738-8e61-4e23-8c70-a53f6fee15d8 Instance ID : uuid:13e590fc-ef22-4291-bd61-4df8eac95efc Format : application/pdf Title : 라인 써멀 프린터 Description : Creator : KCS Producer : Adobe PDF Library 11.0 Keywords : Source Modified : D:20170808045858 Company : HWASUNG SYSTEM Page Layout : OneColumn Page Count : 46EXIF Metadata provided by EXIF.tools