Technical Manual
(Model : HP-500)
CAUTION
• Please do not disassemble / reorganize the product.
• Please do not the remove the paper jam during power on.
• Pleased do not exceed the standard power voltage.
• Please do not wash off the product.
• Please do not press / shock the product.
• Please do not put the product at the moist (humid) condition.
• Please contact us if there is any problem.
• Please power off once remove the paper jam.
• Please clear the air / open the disclosed place.
• Please set the product without damage enviornment.
• Please set the product at the stable place.
• Pleaes keep the requires as necessary as general electrics.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.1
목
차
1. Printer features & External dimension
1-1) Name of each parts
1-2) Operation Part
2. Operation
2-1) Replacing the roll of paper
2-2) Self test
2-3) Communicatino Setting up
2-4) HEX Dump
2-5) Update
2-6) Memory switch
2-7) Way of connecting WiFi or Bluetoorh
(RF Interface)
10
13
3. Genearl Specification
3-1) Specification
3-2) Font
3-3) Inner Buffer
3-4) Electronical Spec
3-5) Operation condition
3-6) MCBF
13
13
13
13
13
13
13
4. Interface Specification
4-1)RS-232C
4-2)USB
4-3)WiFi
4-4)BlueTooth
14
14
14
14
14
5. Command
15
6.Windows Driver
6-1) Set up the function
6-2) Set up the paper
6-3) Set up the new paper
40
40
41
42
7. USB User Interface
7-1) functions
7-2) Caution for using USB Interface
44
44
46
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.2
1. Printer features & External Dimension
1-1) Name of each parts
1. Button and LED
2. Open Lever
3. Maual Cutter
4. Battery
5. DC Connect
6. USB/RS232C Interface
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.3
1-2) Operation Parts
Battery
Power
BlueTooth
WiFi
FEED
Error
* Battary State
3 light is “ Full “ charged.
2 light is “ Middle “ Charged
1 light is “ Low “ it needed to be charged.
If the light in Error LED is “ Very Low “ in a battary
* Power
Power on : Please press the button for 1 sec more.
Power off : Please press the button for 1 sec more.
* FEED
Paper feeding .
* Error
If there is something worng, it will be light as Red when there is no paper or out of bettary
* WiFi and Bluetooth
When operating WiFi or BlueTooth, the LED indicator will be lighting.
* Setting the Lable.
You can use the label paper after setting label option.
① Power on the printer
② Open the paper cover and Press the FEED button for 2 seconds.
③ When Melody is alaming, Put the paper of label in the printer and close the paper cover.
When it comes back to Receipt Option, Please follow this step again.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.4
2. Operation
2-1) Replacing the roll of paper.
The paper setting up is as below.
① Open the cover in Mobile Printer by Lever
②
Please insert the paper, till the paper comes out from
the cover.
Lever
③ Close the cover and cut the extra paper.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.5
2-2 ) Selftest
Please turn off and on the power, while you press down the feed button.
And you can see the Error Led light kept then the following informations are being feeded.
******************************





HP-500 Control Board
Firmware :: Ver0 .45
Create
: 20XX/XX/XX
******************************
Model.
Firmware version / creare date.
Printer information.
Serial I/F information
WiFi information
Printer Information
Battery Volt : 7.7(V)
Hex Dump Mode : OFF
Print Density : Normal
Melody Sound : ON
Paper Type : Receipt
Wireless Type : WiFi / BlueTooth
Power off time : 10 Minute
Tear Bar : 5 Pitch
Serial I/F Information
Baud Rate : 9600
Date Bit : 8 bit
Partiy : None
Stop Bit : 1 or 2
Flow Control : RTS-CTS(DTR-DSR)
WiFi Information
WiFi Mode : AP Mode
IP Address : 192.168.012.101
Gateway : 192.168.012.001
SSID : HWASUNG_4E:8E:EE
SECURITY KEY : 12345678
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.6
2-3 ) Communication setting
Set the printer function and communication condition between host by memory switch utility
program.
※ Note : Setting ereases all contents in memory switch, so code page and print optionshall be set
again.
1 ) Manual setting
Turn on the printer at initial setting mode.
※ Method to go initial setting mode
[ Press and hold FEED button and then turn on power pressing 2 or more seconds, then PE LED and
ERROR LED blinks by turns and it is switched to initial setting mode (9600 BPS, PARITY NONE,
HARDWARE HANDSHAKE).]
In manual setting, considering of communication condition is not required.
2 ) After switched to initial setting mode, followings will be printed.
[Menu]
1.Print Density
2.Melody Sound
3.Paper Type
4.Hex Dump Mode
5.Wireless Type
6.WiFi Mode
7.IP Mode
Select and then Enter...
Enter : Press the feed button once for
more than 1second.
Select: Press the feed button many times
less than 1second as menu number.
Exit : Turn power off then on.
Pressing FEED button for more than 1second, it is fixed(press enter), and less than 1 second, item
is selected.
For example, if you want to change the Wifi Mode of #6 menu, press #6 less than 1 second, and
press more than 1 second. To exit, turn off the power and turn on again.
3) Successively, select from printed items and confirm.
Ex) [Wireless Type]
1.WiFi
-> 2.Bluetooth
-> : Indicate current set status
Select and then Enter...
Ex)
In here, arrow((->) indicates current settings. To change, select item and enter. TO move to
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.7
next menu with no change, just enter without selecting item.
4) Successively, you will know the change result from the printed items.
“ It was changed successfully!”
This message means change was successful.
“ The value is invalid, try again!”
This message is shown when selected item is invalid or when you move to other menu without item
change.
5) Setting result can be confirmed by printing test page or by the location of arrow(->) after selecting
menu item in initial setting mode.
2-4) HEX Dump
Setting up “Hex Dump Mode in Setting Mode. Then it prints all data in hex character
(16 antilogarithm).
You can see the status of receipt. . It will be useful for the appilcation you do.




It prints the data, once it receives the data 12 digit.
You can print the data less than 12 digit, when you press down the button of feed
The control code ( 1F16 below) prints “.”.
The 8016 above prints “^”.
[Printing sample]
16 antilogarithm
[HEX DUMP MODE]
41 42 43 44 45 46 47 47 49
30 31 32 33 34 35 36 37 38
FF 1B 69
ASCII
A B C D E F G H I
0 1 2 3 4 5 6 7 8
^ . i
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.8
2-5) Onboard update
Please conduct the updates, after refering the following steps.
1) Please switch off and on
2) Please check the connection between the printer and the data cable.
* Please make sure about if it is the right cable.
* If use USB cable, save the time to update the firmware
3) Please conduct the provided program , then set up the model and Interface port
If the error LED is turned off and is lighted on slightly after 4 seconds,
then the updated is being started.
* Please do not switch off the printer power, till the update is complete.
4) The update will be complete, once the update indicates complete.
* If the error LED keeps the light goes in and out, it’s error.
Please stop the update program and make sure the cable and other connections.
Please return the process “1.” and follow the step again.
5) Atfer update, automatically the printer will be reset for using and use the printer.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.9
2-6) Memory switch
Please set the function of internal memory.
※ Please use the provided program - ‘memory swtich setting utility program’.
※ The value is not deleted until the next value is changed, even though power off.
Memory SW
Setting Value
SW1
SW2
Reservation
0~1200 or 0~136
SW3
248-4000
SW4
SW5
Base Code Page
Base Font
SW6
Reservation
SW7
Reservation
SW8
Reservation
Descreption
Setting one default value for each country
Setting one of
1) 2byte codes : korean(24 x 24), korean(16 x 16),
Japenes(24x24), Chinese(24x24).
2).1byte codes : ASCII(12x24),
ASCII(8x16,9x16)
Setting
paper
Code Page Manu
Font Manu
After setting, Press the button
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.10
[Memory Switch information]
================================
Code Page = PC437(U.S)
2Byte Font = Korean(24x24)
1Byte Font = ASCII(12x24)
Mem1:FFh
Mem2:FFh,FFh
Mem3:FFh,FFh
Mem4:00h
Mem5:00h
Mem6:FFh
Mem7:FFh
Mem8:FFh
Mem9:FFh
Mem10:FFh
Mem11:40h
Mem12:F9h
(Ex) Sample of printing by selftest
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.11
2-7) The way to connect the RF interface.
1) BlueTooth
BlueTooth inteferface can be set up by simple control
① Please refer to 2-3P and set up from Wireless moder to Bluetooth
② When the Error LED is not lighting, Pressing power button and FEED button togather for
1second then take off.
③ And searching for Bluetooth device in Mobile Phone or PC
④ When finding “HWASUNG_XX:XX:XX”
pairing automatically.
on PC or Smart Phone and choosing it and it will be
⑤ the pairing is complete ordinarily, the light in LED bluetooth will be stopped.
2) WiFi
There are two of modes
Station Mode : Printer will be connected with Wireless directely.(SSID and others Setting necessary)
AP Mode : Printer will be connected with other devices(Not setting necessary)
① Please refer to 2-3 and Set up “ Wireless Mode “
② Please refer to 2-3 and Set up “ Station Mode “ or
When choose
“
AP Mode “ according to where you use.
the mode is “AP Mode “
③ Turn on the printer and atfer 3 second automatically IP Address and SSID and Password will be
printed.
④ And please connect with PC or Smart Phone then put in the SSID and Password.
⑤ When the connection is complete, using IP address printed.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.12
3. General Specification
3-1) Specification
1) Printing
: Direct thermal printer
2) Resolution and Dot : 203dpi, 1dot=0.125mm, 8dot/mm, Total 384 dot
3) Printing speed (Max) : 90mm/sec(Max)
4) Printing Width
: 48mm
5) Paper Width
: 58mm
6) Paper Diameter
: 40 Diameter (Max)
7) Character (MAX) a line : 32fonts (ASCII 12 x 24),16fonts (Korean 24 x 24)
3-2) Font
1) English / Number
2) Graphic
3) International
FONT A(8 x 24) 95, FONT B(8 x 16) 95
FONT A(8 x 24) 128, FONT B(8 x 20) 95
14types 37fonts
(Korean,English,France,Germany,England,Denmark1,Swden,Italy,
Spain1,Japan,Norway,Denmark2,Spain2,Latin America)
4) Korean
FONT A Gothic (24 x 24), FONT B Gothic (16 x 16,option)
3-3) Internal Buffer
Receiver buffer : 4KByte
3-4) Electrical Spec
1) Operating Voltage
Insert Voltage
Operation voltage
Logic voltage
7.4V Li-ion Battery
5V
5V±5%
Motor,Thermal print head
Logic circuit
2) Consumption current
Average : 1.5A(Printing percentage 12.5%))
Peak : 3.7A
3-5) Operation condition (temperature / Humid)
1) Temperature : 0∼40℃
2) Humidity : 40∼90%RH(in not dew condensation)
Notice : The printing is subjet to the operation condition.
3-6) MCBF
1) Mechanism : 15,000,000 Lines.
2) Thermal Print Head 50Km, 1 pulse.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.13
4. Interface specification
4-1) RS-232C
1) Data Transmission : Serial
2) Hand shake
: Hardware (RTS/CTS or DTR/DSR )
3) Baud Rate
: 9600, 19200, 38400, 57600 BPS
4) Data Bit
: 8bit
5) Parity
: None, Odd, Even
6) Stop Bit : 1 or 1.5 or 2 bit
7) Connector
: 10 pin Mini-B(Dedicated Cable)
Pin
Printer
Signal
TxD
RxD
DTR/RTS
GND
Pin
In/Out
Out
In
In
Host
Signal
RxD
TxD
CTS
GND
DSR
In/Out
In
Out
In
In
(Dotted line) : Connect to host.
4-2) USB
1) Standard
: USB 2.0 Compatibility, Full Speed(12Mb)
2) Connector
: Type MINI-B
3) Cable
: USB2.0 Standard Cable
4) Data
: Bulk IN, Bulk OUT
 Bulk IN
: End point 6
 Bulk OUT
: End point 2
 Full Speed : Max Packet Size 64 Byte(Bulk OUT),64 Byte(Bulk IN)
4-3) WiFi
1) Standard
: IEEE 802.11b/g/n,
2) Frequency : 2.400 GHz ~ 2.484 GHz
3) Channel
: CH1 ~ CH11
4) Security
: WEP, WPA/WPA2PSK
4-4) BlueTooth
1) Standard : Bluetooth 3.0 Class2
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.14
5.Commend
Command
CR
LF
CAN
HT
FF
SUB x
SUB p
SUB R
SUB B
SUB 1
SUB 2
SUB W
SUB C
SUB O
SUB F
SUB P
ESC D
ESC SP
ESC !
ESC $
ESC *
ESC ESC 2
ESC 3
ESC @
ESC E
ESC G
ESC J
ESC j
ESC M
ESC R
ESC a
ESC d
ESC {
ESC t
ESC S
ESC L
ESC FF
Function
Print and carriage return
Print and line feed
Cancel the print data
Horizontal tab
Print the page mode / return to the standard mode
Extended graphic mode
Print the off line a paper detection
Outline Character (Tetragon)
2D barcode
Line 1 (Vertical, Horizontal)
Line 2 (Vertical, Horiztontal)
Write (line data)
Clear (line data)
Line ON
Line OFF
Print line 1 dot line (Vertical, Horizontal)
Horizontal tab position
Spacing the character of ASCII
Font decoration
Absolute position of printing
Bit image (vertical)
Underline the character of ASCII
Initial row pitch
Row pitch
Printer reset
Emphasize
Double
FEED
BACK FEED
Font (ASCII)
International character
Align the printing
Printing and row FEED
180° rotation
Code page (International)
Standard mode / Clear the area of page
Page mode
Printing of page area
Title
HP-500 Ver 1
PAGE
17
17
17
17
17
18
18
18
18
19
19
19
19
20
20
20
20
20
21
21
21
23
23
24
24
24
24
24
24
25
25
26
26
26
26
27
27
27
Rev.
Page
Ver1.0
P.15
Command
ESC T
ESC W
FS !
FS &
FS .
FS FS S
FS W
FS q
FS p
GS !
GS (K (fn=49)
GS (K (fn=97)
GS B
GS H
GS L
GS W
GS h
GS k
GS w
GS r
GS a
GS v
DLE ENQ
DLE EOT
Function
Page mode (Direction of printing)
Page mode (Area of printing)
Korean font decoration
Korean extended graphic mode (set up)
Korean extended graphic mode (cancel)
Underline Korean
Space Korean
Size Korean
Register Non Volatile logo (bit image)
Non Volatile logo print
Extension of character
Density of printing
Operating Thermal Head Partially
Reverse printing in black / white
Barcode
Left space
Area of printing
Barcode (Height)
Barcode (Printing)
Barcode (Extension / Reduction)
Status check
Status check (Auto reply)
Laster bit image (Horizontal)
Buffer clear (real time)
Status transmission (real time)
Title
HP-500 Ver 1
PAGE
28
29
30
30
30
31
31
31
32
32
33
33
34
34
34
35
35
35
35
36
37
37
38
38
39
Rev.
Page
Ver1.0
P.16
CR
[Name]
[Format]
[Range]
[Descript]
LF
[Name]
[Format]
[Range]
[Descript]
[Caution]
CAN
[Name]
[Format]
[Range]
[Dsecirpt]
HT
[Name]
[Format]
[Range]
[Descript]
[Caution]
FF
[Name]
[Format]
[Range]
[Descript]
[Caution]
Print and carriage return
ASCII
CR
Hex
0Dh
Decimal
13
equal LF
Print and line feed
ASCII
LF
Hex
0Ah
Decimal
10
① STANDARD MODE:
After printing the data and go to return according as the fixed data.
② PAGE MODE:
The fixed data can be only conduted, according as the fixed data.
The LF is ignored behind of CR
Cancel print data in page mode
ASCII
CAN
Hex
18h
Decimal
24
The data is deleted within the area of printing.
Horizontal tab
ASCII
HT
Hex
09h
Decimal
Moves the print position to the next tab poisition
Horizontal tab position are to set in ESC+’D’+n.
Print and return to standard mode in page mode
ASCII
FF
Hex
0Ch
Decimal
12
Print the data in the print buffer and returns to standard mode
Use the command ESC+FF , in order not to return the standard mode.
The data is not deleted in the area of page.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.17
SUB+’x’+n
[Name]
[Format]
Hex
Decimal
[Range]
[Initial Value]
[Descript]
SUB+’p’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
SUB+’R’+n
[Name]
[Format]
[Range]
[Descript]
[Caution]
Extension Graphic Mode, Korean Mode
ASCII
SUB
1A
78h
26
120
0≤n≤1
n=0
n=0 : Korean Mode, First code is A1h more, automatically transfer Korean
in 2 bytes
n=1 : Extension Graphic Mode, Every code is setting in 1 byte
Extension Graphic font will be printed
Off line printing in paper detection
ASCII
SUB
Hex
1A
70h
Decimal 26
112
0≤n≤1
n=1
n=0 : Not transition to offline once paper empty (data communication available)
n=1 : Transition to offline once paper empty (data communication not avaiable)
Set the character outline
ASCII
SUB
Hex
1A
52h
Decimal 26
82
0≤n≤1
n=0 : cancel character outline (tetragon)
n=1 : Set character outline (tetragon).
The horizontal extension is valid as eight times.
The vertical extension is valid as two times
SUB+’B’+n1+n2+n3+d1……dk
[Name]
[Format]
[Range]
[Descript]
2D Barcode.
ASCII
SUB
n1
n2
n3
Hex
1A
42h
n1
n2
n3
Decimal
26
66
n1
n2
n3
Please refer the table below.
Please choose the barcode by the data of barcode.
d1…………dk
d1…………dk
d1…………dk
n1 : two dimension of barcode
n2 : the number of data of barcode
n3 : size of barcode
d1… dk : the data of barccode
n1
Barcode
PDF417
QR code
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.18
1) PDF417
n2
n3
2) QR code
n2
n3=1
n3=3
n3=5
n3=9
Number of data
1 < n2 ≤ 255
Size of data
Horizontal 3
Horizontal 4
Horizontal 5
Horizontal 6
Horizontal 7
Horizontal 8
Horizontal 9
n3
Number of data
1 < n2 ≤ 17
1 < n2 ≤ 53
1 < n2 ≤ 106
1 < n2 ≤ 230
Size of data
Version 1
Version 3
Version 5
Version 9
※ Vertical is set autom atically.
SUB+’1’
[Name]
[Format]
[Description]
SUB+’2’
[Name]
[Format]
[Description]
Line 1 (Vertical, Horizontal)
ASCII
SUB
Hex
1A
31h
Decimal
26
49
Line of Vertical Horizontal.
Line 2 (Vertical,Horizontal)
ASCII
SUB
Hex
1A
32h
Decimal
26
50
Line of Vertical Horizontal
SUB+’W’+nL+nH+kL+kH
[Name]
Write (line data)
[Format]
ASCII
SUB
nL
nH
kL
Hex
1A
57h
nL
nH
kL
Decimal
26
87
nL
nH
kL
[Range]
0≤nL+(nH×256)≤512、(0≤nL≤255, 0≤nH≤3)
0≤kL+(kH×256)≤512、(0≤kL≤255, 0≤kH≤3)
[Description]
It writes 1 from nL+nH×256 to kL+kH×256.
[Caution]
It is not deleted, till you power off, or you clear the command.
SUB+’C’
[Name]
[Format]
[Description]
[Caution]
kH
kH
kH
Clear (line data)
ASCII
SUB
Hex
1A
43h
Decimal
26
67
It clears all of line zero (0).
Please use this command to write the line again.
Please use the command line ON/ line OFF to write line 1 to speed up the progress.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.19
SUB+’O’
[Name]
[Format]
[Description]
SUB+’F’
[Name]
[Format]
[Description]
SUB+’P’
[Name]
[Format]
[Description]
[Caution]
Line ON
ASCII
SUB
Hex
1A
4Fh
Decimal
26
79
The line data is valid ON. The line prints together, when you print the character.
Line OFF
ASCII
SUB
Hex
1A
46h
Decimal
26
70
The line is valid OFF. The line data is preserved.
Print line 1 dot line (Vertical,Horizontal)
ASCII
SUB
Hex
1A
50h
Decimal
26
80
It prints line 1 dot line.
Please do not use this command, when you print any character,or any graphic.
Please use the command Line ON.
Please use this command, when you print the line at the space.
ESC+’D’+n1…nk+NUL
[Name]
Set the horizontal position
[Format]
ASCII
ESC
n1…nk NUL
Hex
1B
44h
n1…nk 00
Decimal 27
68
n1…nk 0
[Range]
1≤n≤255, 0≤k≤32
[Descript]
Set the horizontal tab position
[Caution]
n : Indicating the figures from the start poistion of line to set position
K : indicating the total tabs a line
ESC+SP+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
[Caution]
Set the space amount on the right of ASCII character
ASCII
ESC
SP
Hex
1B
20h
Decimal
27
32
0≤n≤255
n=0
Set in n x 0.125mm the space amount on the right of ASCII character
Set the Korean space in FS+’S+n
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.20
ESC+’!’+n
[Name]
[Format]
Font decoration
ASCII
ESC
Hex
1B
21h
Decimal
27
33
0≤n≤255
n=0
It sets the font decoration in the same time.
[Range]
[Initial]
[Description]
Bit
Function
0: Font 12x24, 24x24
1: Font 8x16, 16x16
0: Cancel the highlight
1: Set the highlight
0: Cancel the extension in Vertical
1: Set the extension in Vertical
0: Cancel the extension in Horizontal
1: Set the extension in Horizontal
0: Cancel the underline
1: Set the underline
ESC+’$’+nL+nH
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
Hex
00h
01h
00h
08h
00h
10h
00h
20h
00h
80h
Decimal
16
32
128
Set absolute poisition
ASCII
ESC
nL
nH
Hex
1B
24h
nL
nH
Decimal
27
36
nL
nH
0≤nL+nH×256≤65535, 0≤nL≤255, 0≤nH≤255
nL=0, nH=0
Move the printing position from left ending space to (nL+nH×256)×0.125mm
Move the printing position in left ending once printing position is over.
ESC+’*’+m+nL+nH+d1+…+dk
[Name]
Set the bitmap image
[Format]
ASCII
ESC
nL
Hex
1B
2Ah
nL
Decimal
27
42
nL
[Range]
m=0,1,32,33
1≤nL+nH×256≤1023, 0≤nL≤255, 0≤nH≤3, 0≤d≤255
[Descirpt]
nH
nH
nH
d1…dk
d1…dk
d1…dk
Due to fixing nL+nHx256, Printing from bit data to graphic data in Mode m
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.21
m
Mode
8dots
Single Density
Dots in
Dots in
vertical
horizontal
224
Data (k)
nL+nH×256
8dots
Double Density
448
nL+nH×256
32
24dots Single Density
24
224
(nL+nH×256)×3
33
24dots Double Density
24
448
(nL+nH×256)×3
•8 dots Mode
D1
D2
Twice
D3
once
MSB
LSB
D1
D2
D3
Single
Title
HP-500 Ver 1
Double
Rev.
Page
Ver1.0
P.22
•24 dots Mode
Twice
D1 D2 D3 D4 D5 D6 D7 D8 D9
Once
MSB
Once
Once
LSB
D1
D4
D7
D2
D5
D8
D3
D6
D9
Single
Density
ESC+’-’+n
[Name]
[Format]
Set / Cancel underline
ASCII
ESC
Hex
1B
Decimal
27
[Range]
0≤n≤255,
[Invitial Value]
n=0,
[Descript]
Set / Cancel underline
Function
Cancel underline
Set underline in thick 0.125mm
Set underline in thick 0.25mm
Set underline in thick 0.375mm
Set underline in thick 0.5mm
Set underline in thick 0.625mm
Set underline in thick 0.75mm
Set underline in thick 0.875mm
ESC+’2’
[Name]
[Format]
[Range]
[Initial Value]
[Descirpt]
2Dh
45
Double
Density
Set the interval of initial line
ASCII
ESC
Hex
1B
32h
Decimal
27
50
0≤n≤255,
n=0
Set the interval of initial value in 4mm
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.23
ESC+’3’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
ESC+’@’
[Name]
[Format]
[Range]
[Descript]
ESC+’E’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
ESC+’G’+n
Name]
[Format]
[Range]
[Initial Value]
[Descript]
ESC+’J’+n
[Name]
[Format]
[Range]
[Descript]
ESC+’j’+n
[Name]
[Format]
[Range]
[Descript]
Set the interval of line
ASCII
ESC
Hex
1B
33h
Decimal
27
51
0≤n≤255,
n=0
Set the interval of line in n x 0.125mm
Rest printer
ASCII
ESC
Hex
1B
40h
Decimal
27
64
0≤n≤255,
Clear buffer & Initialize all parameter
Set the font in thick
ASCII
ESC
Hex
1B
45h
Decimal
27
69
0≤n≤255,
n=0
n=0, cancel the font in thick
n=1, set the font in thick
Set the printing double for font thickness
ASCII
ESC
Hex
1B
47h
Decimal
27
71
0≤n≤255,
n=0.
n=0. cancel the printing twice for font thickness.
n=1. set the printing twice for font thickeness.
Feeding
ASCII
ESC
Hex
1B
4Ah
Decimal
27
74
0≤n≤255
Printing the data inner buffer, feeding in n x 0.125mm
Back Feeding
ASCII
ESC
Hex
1B
6Ah
Decimal
27
106
0≤n≤255
Printing the data inner buffer and back feeding in n x 0.125mm
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.24
ESC+’M’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
Select font
ASCII
ESC
Hex
1B
Decimal
27
0≤n≤2
n=0
Select printer font
4Dh
77
Precedence 4bits(Korean fonts)
0000
Korean 24x24 Gothic
0001
Korean 16 x 16 General
0010
Japanese 24 x 24 Bodoni
0011
Chinese 24 x 24 Gothic
0000
0001
0010
0011
Subordinate 4bits (ASCII)
Korean 24x24 Gothic
Korean 16 x 16 General
Japanese 24 x 24 Bodoni
Chinese 24 x 24 Gothic
Notice : When you set up one of fonts, you can use “Memory Switch Setting program “ without
commend. If you need any more information, please refer to How to use Memory Switch Setting
Program.
* Caution : In case of Big Font as 56x88, it would be possible to extend font size as much as
Double(Width and Length) and other fonts would be possible to extend the font size as
Octuple
ESC+’R’+n
[Name]
[Format]
Select the International character
ASCII
ESC
Hex
1B
52h
Decimal
27
82
0≤n≤13
n=13
Select the international character as follows:-
[Range]
[Initial Value]
[Descirpt]
10
11
12
13
Country Name
USA
France
Germany
England
Denmark1
Sweden
Italian
Spain1
Japanese
Norway
Denmark2
Spain2
Latin America
Korea
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.25
ESC+’a’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
Align the printing
ASCII
ESC
Hex
1B
61h
Decimal
27
97
0≤n≤2
n=0
Align the printing position
ESC+’d’+n
[Name]
[Format]
[Range]
[Descript]
ESC+’{’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
[Caution]
[Range]
[Initial Value]
[Descript]
[Caution]
Printing Position
Left
Middle
Right
Printing and feeding ‘n’ line
ASCII
ESC
Hex
1B
64h
Decimal
27
100
0≤n≤255
Printing the date & feeding ‘n’ line
Turning 180°
ASCII
ESC
Hex
1B
7Bh
Decimal
27
123
0≤n≤255
n=0
Set the reverse image
Move the standard from the left to the right
ESC+’t’+n
[Name]
[Format]
Function
Cancel 180°
Set 180°
International code page
ASCII
ESC t
Hex
1B
74h
Decimal 27
116
0≤n≤5 14≤n≤17
n=0
You can see the following table of the international code page.
It is valid, if you direct the command SUB+”x” for 1 byte.
It is not valid, if you direct the command SUB+”x” for 2 bytes.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.26
n
ESC+’S’
[Name]
[Format]
[Descript]
10
code page
PC850((Multilingual)
PC860(Portugal)
Windows1252
Iran System Encoding Standard
PC857(Turkish)
Set the Standard mode
ASCII
ESC
Hex
1B
53h
Decimal
27
83
Swtiches from page mode to standard mode and the data is deleted at the page.
ESC+’L’
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
ESC+FF
[Name]
[Format] ASCII
[Descript]
code page
PC437(US)
KANA(JAPAN)
GREEK
Windows1251
PC866(Cyrllic #2)
Windows1250 (Poland)
Select page mode
ASCII
ESC
Hex
1B
4Ch
Decimal
27
76
0≤n≤255
n=0
Switches from standard mode to page mode
Printing as the page mode
ESC
FF
Hex
1B
0Ch
Decimal
27
12
It prints the data at the page mode.
(The data is NOT deleted at the page.)
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.27
ESC+’T’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
Select print direction in page mode
ASCII
ESC
Hex
1B
54h
Decimal
27
84
0≤n≤3
n=0
Select the print direction & start position in page mode
•n=0(Left→Right),
•n=1(Bottom→Top),
ABCD
Feeding
ABCD
Feeding
•n=2(Right→Left),
•n=3(Top→Bottom),
ABCD
Feeding
Feeding
ABCD
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.28
ESC+’W’+xL+xH+yL+yH+dxL+dxH+dyL+dyH
[Name] Set printing area in page mode
[Format ] ASCII ESC W xL xH yL yH dxL dxH dyL dyH
Hex
1B 57h xL xH yL yH dxL dxH dyL dyH
Decimal 27 87 xL xH yL yH dxL dxH dyL dyH
[Range]
[Initial Value]
[Descript]
[Caution]
0≤xL+xH×256≤65535 (0≤xL≤255, 0≤xL≤255)
0≤yL+yH×256≤65535 (0≤yL≤255, 0≤yL≤255)
1≤dxL+dxH×256≤65535 (0≤dxL≤255, 0≤dxL≤255)
1≤dyL+dyH×256≤65535 (0≤dyL≤255, 0≤dyL≤255)
(xL+xH×256)=0 (0mm, xL=0, xH=0)
(yL+yH×256)=0 (0mm, yL=0, yH=0)
(dxL+dxH×256)=448 (56mm, dxL=C0h, dxH=01h)
(dyL+dyH×256)=1200 (150mm, dyL=B0h, dyH=04h)
Set printing area & starting point
Horizontal starting point : (xL+xH×256) × 0.125mm
Vertical starting point : (yL+yH×256) × 0.125mm
Horizontal size : (dxL+dxH×256) × 0.125mm
Vertical size
: (dyL+dyH×256) × 0.125mm
The maximum page width is available 56mm
The maximum page length is available 150mm
Barcode & graphic data is executed as per standard line,
If the size exceed the standard line, move the standardline by CR or LF.
: Barcode or Graphic
Paper
(x,y)
ABCD
dx
Paper
EFGH
Standard
Move the standard line
by CR or LF
Printing Area
dy
Printing before
moving
the standard line
EFGH
(x+dx,y+dy)
Printing after
ABCD
moving
the standard line
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.29
FS+’!’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
[Caution]
Bit
Set the printing mode in Korean
ASCII
FS
Hex
1C
21h
Decimal
28
33
0≤n≤255
n=0
Set the printing mode in Korean
Only valid in Koean
Function
Cancel the horizontal extension
Hex
00h
00h
00h
Decimal
Set the horizontal extension
Cancel the vertical extension
04h
00h
Set the vertical extension
Cancel the underline
Set the underline
08h
00h
00h
00h
00h
80h
128
FS+’&’
[Name]
[Format]
[Descript]
[Caution]
FS+’.’
[Name]
[Format]
[Descript]
[Caution]
Set to print Korean mode (2bytes Mode)
ASCII
FS
Hex
1C
26h
Decimal
28
38
Set to print Korean mode (2bytes Mode)
Set to print Korean mode in extended graphic mode
Appointment is not required in Korean mode, due to auto detection.
(Ref.SUB+’x’+n command)
Cancel Korean mode (2Bytes mode)
ASCII
FS
Hex
1C
2Eh
Decimal
28
46
Cancel Korean mode (2Bytes mode)
In case of cancel 2 bytes mode in extended graphic mode
Appointment is not required due to auto detection in Korean mode
(Ref.SUB+’x’+n command)
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.30
FS+’-’+n
[Name]
[Format]
Set the underline of Korean
ASCII
FS
Hex
1C
2Dh
Decimal
28
45
0≤n≤2
n=0
Set the underline of Korea
[Range]
[Initial Value]
[Descript]
Function
Cancel the underline of Korean
Set the thickness of underline in 0.125mm
Set the thickness of underline in 0.25mm
FS+’S’+n1+n2
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
FS+’W’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
Set the space between Korean characters
ASCII
FS
n1
Hex
1C
53h
n1
Decimal
28
83
n1
0≤n1≤255, 0≤n2≤255
n=0
Set the space between Korean characters
Set the left space in n1×0.125mm
Set the right space in n2×0.125mm
n2
n2
n2
Set the font size in Korean
ASCII
FS
Hex
1C
57h
Decimal
28
87
0≤n1≤255
n=0
Set the Korean font size twice (HorizontalxVertical) in Korean
n=0, Cancel the font size two times
n=1, Set the font size two times
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.31
FS+’q’+n+(xL+xH+yL+yH+d1…dk)1……+(xL+xH+yL+yH+d1…dk)n
[Name]
Register logo (bitmap image) non volatilization
[Format]
ASCII
FS
n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n
Hex
1C 71h n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n
Decimal 28 113 n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n
[Range]
1≤n≤255
0≤xL+xH×256≤65535 (0≤xL≤255, 0≤xH≤255)
0≤yL+yH×256≤65535 (0≤yL≤255, 0≤yH≤255)
0≤d≤255
k=(xL+xH×256)×(yL+yH×256)×8, Capable register : 64kbytes
[Descript.]
[Caution]
Register the logo non-volatilization
n : Total unit of N/V logo
xL,xH : Set the horizontal dot in (xL+xH×256)×8
yL,yH : Set the vertical dot in (xL+xH×256)×8
k : Bitmap image of a N/V logo
Register various as much as NV’s capa.
Required to delete all if (it is) registered again.
Renewable registeration / deletion at 100000 cycles,
It’s not recommended frequent registeration / deletion,
due to memory damage

D1
D(x×8-1)×y+1
. . .
. . .
. . .
Dy
D(x×8)×y
FS+’p’+n+m
[Name]
[Format]
Printing N/ V logo
ASCII
FS
Hex
1C
70h
Decimal
28
112
1≤n≤255, 0≤m≤3
n=0
m : printing the registered N/V in ‘m’ mode
n : indicating the regsitered logo in the ‘n’.
[Range]
[Initial Value]
[Descript.]
MSB
LSB
Printing mode
Standard
Horizontal extension
Vertical extension
Horizontal,vertical extension in the same time
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.32
GS+’!’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript.]
[Caution]
Set the proportion of character extention
ASCII
GS
Hex
1D
21h
Decimal
29
33
0≤n1≤255 (horizontal / vertical portions is restricted maxim value 8)
n=0
Set the proportion of character extention
Caculate the numberic value,
if vertical & horizontal is extended in the same time
ex.) x3 (Horizontal Rate), x3(Vertical Rate) : n=32+2=34
Bit
0-3
Set the extension proportion in vertical
Function
4-7
Set the extension proportion in horizontal
Extension in Horizontal
n(Hex)
n(Decimal)
00h
10h
16
20h
32
30h
48
40h
64
50h
80
60h
96
70h
112
Rate
x1
x2
x3
x4
x5
x6
x7
X8
Extension in Vertica
n(Hex) n(DecimaL)
Rate
00h
x1
01h
x2
02h
x3
03h
x4
04h
x5
05h
x6
06h
x7
07h
X8
GS+’(’+’K’+pL+pH+fn+m (fn=49)
[Name]
Set the printing density
[Format]
ASCII GS
pL
pH
fn
Hex
1D
28h
4Bh
pL
pH
Decimal
29
40
75
pL
pH
[Range]
pL=2, pH=0, fn=49
1≤m≤30
[Initial Value]
It set up automatically as per the voltage. (Ref.Table below)
[Descript]
Set the printing density
Drive Voltage (Vp)
5 ~ 5.4V
5.5 ~ 5.9V
6 ~ 6.4V
6.5 ~ 6.9V
7.0 ~ 7.4V
7.5 ~ 7.9V
8.0 ~ 8.3V
8.4V ~ 8.5V
fn
fn
26
16
10
※ Once it is a power on reset, the density is set up automatically,
You can choose the density as per the conditions, such as power,printing quality.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.33
GS+’(’+’K’+pL+pH+fn+m (fn=97)
[Name]
Operating thermal head partially
[Format]
ASCII
GS
pL
pH
fn
Hex
1D
28h
4Bh
pL
pH
fn
Decimal
29
40
75
pL
pH
fn
[Range]
pL=2, pH=0, fn=97
0≤m≤4
[Initial Value]
m=2 (3 partiation)
[Descript]
Set the operation of partial thermal head
[Caution]
This function is effective in case of power capa is short.
The current electric will be reduced as big as the partition.
GS+’B’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
GS+’H’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
Thermal Head Partition operation
First Partition
Second Partition
Third Partition
Fourth Partition
Fifth Partition
Reverse printing in black
ASCII
GS
Hex
1D
42h
Decimal
29
66
0≤n≤255
n=0
Reverse printing in black
n=0, standard printing
n=1, reverse printing in black
Select the printing position of HRI characters (Barcode)
ASCII
GS
Hex
1D
48h
Decimal
29
72
0≤n≤3
n=0
Select the printing positions of numerical value & characters
Printing Position
Non printing
Above the barcode
Below the barcode
Both above & below barcode
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.34
GS+’L’+nL+nH
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
GS+’W’+nL+nH
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
Select the left margin
ASCII
GS
nL
nH
Hex
1D
4Ch
nL
nH
Decimal
29
76
nL
nH
0≤nL≤255, 0≤nH≤255
nL+nH×256=0 (nL=0, nH=0)
The left margin is set in (nL+nH×256)×0.125mm.
Set printing area width
ASCII
GS
nL
nH
Hex
1D
57h
nL
nH
Decimal
29
87
nL
nH
0≤nL≤255, 0≤nH≤255
nL+nH×256=448 (56mm, nL=0, nH=0)
Set printing area width from the left margin in (nL+nH×256)×0.125mm
Printing area
Left Margin
GS+’h’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript]
Printing area width
Select barcode height
ASCII GS
Hex
1D
68h
Decimal
29
104
1≤n≤255
n=162 (20.25mm)
Select barcode height by n×0.125mm
GS+’k’+m+d1…dn+NUL
[Name]
[Format]
[Range]
[Descript]
Print barcode
ASCII
GS
d1…dn NUL
Hex
1D
6Bh
d1…dn 00h
Decimal
29
107
d1…dn 0
1≤m≤7, n & d depend on barcode system used
Refer the table as below
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.35
m
Barcode system
(Barcode data numbers)
d (barcode data )
UPC-E
n=7 (check digit is automatically added )
48≤d≤57
EAN13
n=12 (check digit is automatically added)
48≤d≤57
EAN8
n=7 (check digit is automatically added)
48≤d≤57
CODE39
1≤n (Start & Stop characteres is automatically
48≤d≤57, 65≤d≤90
added
d=32,36,37,43,45,46,47
48≤d≤57
ITF(I of 2/5)
1≤n
CODABAR
1≤n
(Only even number)
48≤d≤57, 65≤d≤68
d=36,43,45,46,47,58
2≤n≤255 (Check digit , Stop character
CODE128
0≤d≤127
Is automatically added)
[Caution] In CODE128, set additional “{“ in 2bytes when the special character as below
Special
character
SHIFT
CODE A
CODE B
CODE C
FNC1
FNC2
FNC3
FNC4
“{“
ASCII
{S
{A
{B
{C
{1
{2
{3
{4
{{
Barcode data
Hex
7Bh, 53h
7Bh, 41h
7Bh, 42h
7Bh, 43h
7Bh, 31h
7Bh, 32h
7Bh, 33h
7Bh, 34h
7Bh, 7Bh
Decimal
123, 83
123, 65
123, 66
123, 67
123, 49
123, 50
123, 51
123, 52
123, 123
GS+’w’+n
[Name]
[Format]
[Range]
[Initial Value]
[Descript.]
Set the vertical size of barcode
ASCII
GS
Hex
1D
77h
Decimal
29
119
1≤n≤4
n=2
Set the horizontal size of barcode
Module barcode width
0.25mm
0.375mm
0.5mm
0.625mm
Two level barcode
Narrow
Wide
0.125mm
0.375mm
0.25mm
0.625mm
0.375mm
1mm
0.5mm
1.25mm
* Multi Level barcode : UPC-E, EAN13, EAN8
* 2 level barcode
: CODE39, ITF, CODABAR
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.36
GS+’r’+n
[Name]
[Format]
Transmit status
ASCII
GS
Hex
1D
72h
Decimal 29
114
n=1
Transmit current status of printer
The status is not ready till the printer is offline,
The command is executed when the data in receive buffer is devloped
Therefore automatic status function (GS+’a’+n) is to use better,
It is used for re-confirm in on-line after automatic status is received
[Range]
[Descript]
[Caution]
GS+’a’+n
[Name]
[Format]
Enable / Disable automatic status back (ASB)
ASCII
GS
Hex
1D
61h
Decimal
29
97
0≤n≤1
n=1
Enable / Disable ASB
If the status is changed after checking the printer status,
the status is automatically executed.
This command is executed to enable or disable.
[Range]
[Initial Value]
[Descript]
Function
Disable automatic status back
Enable automatic status back

Bit
0 : Paper
1 : No paper
0 : Printer head down
1 : Printer head up
0 : Paper w/o jamm
1 : Paper with jamm
0 : Paper enough
1 : Paper Near End
0 : Print complete
1 : Print or Feeding
Hex
00h
01h
00h
02h
00h
04h
00h
08h
00h
10h
00h
Decimal
16
00h
00h
Satus
※ the status of bit 4 is effective when the realtim e conducts
the command DLE + EOT + n, The others are fixed ‘0’.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.37
GS+’v’+’0’+m+xL+xH+yL+yH+d1+…+dk
[Name]
[Format]
Laster bit image
ASCII
GS
xL xH yL yH d1..dk
Hex
1D 76h
30h
xL xH yL yH d1..dk
Decimal 28 118
48
xL xH yL yH d1..dk
0≤m≤3 or 48≤m≤51,
1≤(xL+xH×256)≤150
(0≤xL≤150, xH=0)
1≤(yL+yH×256)≤436
(0≤yL≤255, 0≤yH≤1)
0≤d≤255 (yL+yH×256)
K (All data) = (xL+xH×256) × (yL+yH×256)
The laster bit image will be recognized in mode ‘m’.
xL,xH appoint the data (byte) of horizontal at image data.
yL,yH appoint the dta (dot line) of vertical at image data.
[Range]
[Descript]
* d is a data for laster bit.
0, 48
1, 49
2, 50
3, 51
Mode
Normal
Horizontal expansion
Vertical expansion
Horizontal,Vertical expansion
Expansion
x1
x2
x2
x2 (Horizontal & Vertical)
Ex) Expansion image
xL+xH×256 = 32 byte,
32 × 8 = 256 dot
33
34
35
……
……
k-31
k-30
30
31
32
……
62
63
64
……
……
……
……
……
k-29
……
k-2
k-1
7 6
MSB
……
yL+yH×256 dot line
1 0
LSB
DLE+ENQ+n
[Name]
Realtime request the printer to be clear each buffer
[Format]
ASCII
DLE
ENQ
Hex
10h
05h
Decimal
16
[Range]
n=2
[Descript]
The realtime clear each buffer as soon as this command receive.
[Caution]
It’s only valid as you switch up ‘1’ as ‘ON’.
This command is only effective if the printer is off.
This command is only effective if it receives the data as same command.
This command is not effective if it’s online.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.38
DLE+EOT+n
[Name]
[Format]
[Range]
[Descript]
[Caution]
Realtime status transmission
ASCII
DLE
EOT
Hex
10h
04h
Decimal 16
n=2
The real time transmits a byte as soon as this command receives.
It’s only valid as you switch up ‘1’as ‘ON’.
Please refer status table at the page 29.
If the command is received same data, it could be same operation
(Bit image data,etc)
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.39
6. Widows Driver
6-1) Set up the function.
1) Please open the screen of printer / fax, and click the basic setting (I) of the general tap.
2) Please click (V).
3) Please refer to the following images, and set up each details.
6-2) Set up the paper.
Please set the form feeding after printing.
1) Please click the basic setting (I) of the general tap.
2) Please click the tap of paper /quality, and drop down paper providing.
3) Auto & Role Feeder : After printing, the form feeding is not conducted any more.
Please set up if the printing length is not regular.
You can’t conduct the feeding, even you set up the space at the program Visual Basic.
We recommend you make the font size smaller, such as “.”, and make the position
the cutting.
Example)
'----- Example Dummy form feeding to cutting position --------Printer.Print " " & vbLf
Printer.Print " " & vbLf
Printer.Print " " & vbLf
Printer.FontSize = 2
Printer.Print "."
Printer.EndDoc
' dummy print for form feeding
4) Page length Feeder : After printing, The form feeding will be conducted
as long as the length is fixed. It is mostly used when the regular legnth is printed.
6-3) Set up the new paper.
You can make the size of paper you need.
Please refer the example of 60mm x 150mm as below.
1) Please open the screen of printer & fax,and click the server on file / menu.
2) Please choose the STANDARD(Size 80 x 400mm) as image.
3) Please tick ‘new documentation (C)’ as image.
4) Please type the width 6.0 cm / the height 15.0 cm as image.
5) Please click the ‘form install’ Ticket (Size 60 x 150mm) as image.
6) Please click the tap ‘advanced’ and set the paper Ticket(Size 60 x 150mm).
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.40
. USB (User Interface)
Without using the Windows driver, you are able to check the printer status, and transmit / receive the
data,
by using USB Interface DLL (HwaUSB.DLL) and OCX driver (HwaUSB.OCX).
7-1) DLL Interface
Please add the file HwaUSB.DLL at the folder System 32, or the folder SysWow64.
7-1-1) DLL function.
1) long UsbOpen(LPCTSTR SelPrinter);
Please open the port USB by the printer Model “HP-500”


Parameters:
SelPrinter : Printer Model Name
Return :
Open normal : 0
Open error : -3(minus)
2) long PrintStr(LPCTSTR data);
It prints the string.


Parameters:
data : String datas
Return :
Print normal : 1
Print error : 0
Notice : To prevent the loss of data for the print timeout ,
Please use the function ‘NewRealRead’ to check the status,and go to the next step,
when it’s normal.
3) long PrintCmd(unsigned char data);
It prints the data one (1) byte.
Please use the ‘PrintPackage function’ as below, if there are a lot of datas to print.
Then you are able to increase the speed of the transmission.


Parameters:
data : one (1) byte data (0~255)
Return :
Print normal : 1
Print error : 0
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.41
4)long NewRealRead(void);
It reads the printer status data as one (1) byte by the port USB.


Parameters:
None
Return :
Read normal : Printer status value.
Read error : -1( minus )
5)long PrintPacket(unsigned char *PacketBuf,unsigned long PacketLength);
It prints the data by the port USB, as much as the data at the transmission data buffer .

Parameters:
PacketBuf : Transmission data buffer pointer.
PacketLength : Transmissiong data length
Notice : Please do not exceed more than 64 bytes max.

Return :
Print normal : 1
Print error
:0
Notice Please do not use any function we don’t provide, due to the debug usage.
Notice Please ask the sample program for more details.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.42
7-2) Caution for using USB Interface
If you use the USB interface and windows drivers together, the data will not be printed in regular
sequence. So please release the spool, when you wan to use the USB interface and window
driver together. If you release the spool, the data receipt is only made by USB Interface.
※ The Data diafram of window application.
Window Application
Window Driver
(Graphic)
USB Port
Printer
DLL Interface
OCX Driver
(Command,
Character)
Send
Receive (Printer State Date)
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.43
No.
Date
2017.05.02
Descripction
Page
Release HP-500 V1.0
Title
HP-500 Ver 1
Ver.
V1.0
Rev.
Page
Ver1.0
P.44
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to correct the interference by one of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from which the receiver is
connected. • Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter.
Title
HP-500 Ver 1
Rev.
Page
Ver1.0
P.45

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : KCS
Create Date                     : 2017:08:08 16:18:17+09:00
Modify Date                     : 2017:08:08 16:18:32+09:00
Subject                         : 
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2017:08:08 16:18:32+09:00
Creator Tool                    :  Word용 Acrobat PDFMaker 11
Document ID                     : uuid:93c48738-8e61-4e23-8c70-a53f6fee15d8
Instance ID                     : uuid:13e590fc-ef22-4291-bd61-4df8eac95efc
Format                          : application/pdf
Title                           : 라인 써멀 프린터
Description                     : 
Creator                         : KCS
Producer                        : Adobe PDF Library 11.0
Keywords                        : 
Source Modified                 : D:20170808045858
Company                         : HWASUNG SYSTEM
Page Layout                     : OneColumn
Page Count                      : 46
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ALRM-HP-500

Navigation menu