ADC Telecommunications FSN-809019-2 InterReach Fusion FSN-809019-2 User Manual fusionBOOK
ADC Telecommunications Inc. InterReach Fusion FSN-809019-2 fusionBOOK
Contents
- 1. User Manual Part One
- 2. User Manual Part Two
User Manual Part Two
Installing Fusion SECTION 7 This section contains the following subsections: • Section 7.1 Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 • Section 7.2 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 • Section 7.3 Preparing for System Installation . . . . . . . . . . . . . . . . . . . . . . . . . 7-6 • Section 7.4 Fusion Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10 • Section 7.5 Splicing Fiber Optic Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-37 • Section 7.6 Interfacing the Fusion Main Hub to an RF Source . . . . . . . . . . 7-39 • Section 7.7 Connecting Contact Alarms to a Fusion System . . . . . . . . . . . . 7-49 • Section 7.8 Alarm Monitoring Connectivity Options . . . . . . . . . . . . . . . . . . 7-57 7.1 Installation Requirements Before and during installation, keep in mind these sources of potential problems: • Faulty cabling/connector • Dirty connectors and ports • Malfunction of one or more Fusion components • Antenna, base station, or repeater problem • External RF interface • Tripped circuit breaker • Equipment is not grounded • Using a crossover Ethernet cable that does not support full hardware handshaking when using AdminBrowser InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A 7-1 CONFIDENTIAL Installation Requirements NOTE: Faulty cabling is the cause of a vast majority of problems. All CATV cable should be tested to TIA-570-B specifications. 7.1.1 Component Location Requirements Fusion components are intended to be installed in indoor locations only. If outdoor installation is desired, such as a parking garage, the Fusion components must be installed in the appropriate environmental enclosures. 7.1.2 Cable and Connector Requirements Fusion equipment operates over the following: • CATV 75 Ohm cable with F connectors • Single-mode fiber (SMF) or multi-mode (MMF) cable with SC/APC fiber connectors throughout the fiber network, including fiber distribution panels These cables are widely-used, industry standards for the cable TV industry. The regulations and guidelines for Fusion cable installation are identical to those specified by the TIA/EIA 568-B standard and the TIA/EIA/570-A standards. LGC Wireless recommends solid copper center conductor, plenum-rated CATV cable and connectors for conformity to building codes, standards, and to ensure stated performance of maximum distance and RF specifications. CommScope 2065V cable or equivalent is required for RG-59. CommScope 2279V cable or equivalent is required for RG-6. CommScope 2293K cable may also be used for RG-11. NOTE: Refer to Appendix A for more information related to 75 Ohm CATV. LGC Wireless recommends connectors with fixed centerpins to ensure proper seating and to eliminate oxidation, which occurs with bare center conductors. Recommended connectors are as follows: CANARE Connectors • FP-C4F for commScope 2065V cable • FP-C55A for CommScope 2279V cable • FP-C71A for CommScope 2293K cable 7-2 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Safety Precautions NOTE: The proper crimp tool and die must be matched by the connector type. 7.1.3 Distance Requirements Table 7-1 shows the distances between Fusion components and related equipment. Table 7-1 Distance Requirements Equipment Combination Cable Type Cable Length Additional Information Repeater/BTS to Fusion Main Hub Coaxial; N male connectors 3–6 m (10–20 ft) typical Limited by loss and noise. Refer to your link budget calculation. 10 m (33 ft) maximum Limited by CE Mark requirements. Fusion Expansion Hub to RAU CATV 75 Ohm; shielded F male connectors • Minimum: 10 meters (33 ft) • Maximum: 150 meters (492 ft) for RG-59; 170 meters (558 ft) for RG-6; 275 meters (902 ft) for RG-11 Refer to Table 5-1 and Table 5-2. Refer to “System Gain” on page 6-11. Main Hub to Expansion Hub Multi-mode fiber: Single-mode fiber: SC/APC male connectors 500 m (1640 ft.) maximum 6 km (19,685 ft.) maximum Limited by 3 dB optical attenuation RAU to passive antenna Coaxial; N male connectors 1–3.5 m (3–12 ft) typical Limited by loss and noise. 7.2 7.2.1 Refer to your link budget calculation. Safety Precautions Installation Guidelines Use the following guidelines when installing LGC Wireless equipment: 1. Provide sufficient airflow and cooling to the equipment to prevent heat build-up from exceeding the maximum ambient air temperature specification. Do not compromise the amount of airflow required for safe operation of the equipment. 2. If you are removing the system, turn it off and remove the power cord first. There are no user-serviceable parts inside the components. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-3 CONFIDENTIAL Safety Precautions 3. The internal power supplies have internal fuses that are not user replaceable. Consider the worst-case power consumption shown on the product labels when provisioning the equipment’s AC power source and distribution. 4. Verify that the Hub is grounded properly using the AC power cord third wire ground. NOTE: Be careful with the mechanical loading of the rack mounted hub. Mount the equipment in the rack in such a way that a hazardous condition, due to uneven mechanical loading, does not result,. 7.2.2 General Safety Precautions The following precautions apply to LGC Wireless products: • The units have no user-serviceable parts. Faulty or failed units are fully replaceable through LGC Wireless. Please contact us at: 1-800-530-9960 (U.S. only) +1-408-952-2400 (International) • Although modeled after an Ethernet/LAN architecture and connectivity, the units are not intended to connect to Ethernet data hubs, routers, cards, or other similar data equipment. • When you connect the fiber optic cable, take the same precaution as if installing Ethernet network equipment. All optical fiber SC/APC connectors should be cleaned according to the cable manufacturer’s instructions. • When you connect a radiating antenna to an RAU, firmly hand-tighten the N connector – DO NOT over-tighten the connector. WARNING: To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture. The components are intended for indoor use only. Do not install the RAU outdoors. Do not connect an RAU to an antenna that is located outdoors where it could be subject to lightning strikes, power crosses, or wind. • The Expansion Hub and RAU units are designed for intra-building cabling only. Outdoor routing of any cabling to these units shall not exceed 140 feet. NOTE: Outdoor cables farther than 140 feet must be installed with proper lightning protection. 7-4 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Safety Precautions 7.2.3 Fiber Port Safety Precautions The following are suggested safety precautions for working with fiber ports. For information about system compliance with safety standards, refer to Appendix B. WARNING: Observe the following warning about viewing fiber ends in ports. Do not stare with unprotected eyes at the connector ends of the fibers or the ports of the hubs. Invisible infrared radiation is present at the front panel of the Main Hub and the Expansion Hub. Do not remove the fiber port dust caps unless the port is going to be used. Do not stare directly into a fiber port. • Test fiber cables: When you test fiber optic cables, connect the optical power source last and disconnect it first. Use Class 1 test equipment. • Fiber ends: Cover any unconnected fiber ends with an approved cap. Do not use tape. • Broken fiber cables: Do not stare with unprotected eyes at any broken ends of the fibers. Laser light emitted from fiber sources can cause eye injury. Avoid contact with broken fibers; they are sharp and can pierce the skin. Report any broken fiber cables and have them replaced. • Cleaning: Be sure the connectors are clean and free of dust or oils. Use only approved methods for cleaning optical fiber connectors. • Modifications: Do not make any unauthorized modifications to this fiber optic system or associated equipment. • Live work: Live work is permitted because LGC Wireless equipment is a Class 1 hazard. • Signs: No warning signs are required. • Class 1 laser product: The system meets the criteria for a Class 1 laser product per IEC 60825-1: 1993+A1:+A2:2001 and IEC106825-2. CLASS CLASS11 LASER PRODUCT This mark appears on the front panel of the Main Hub and the Expansion Hub. LASER PRODUCT Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001. The hazard level at all locations within the equipment is Hazard Level 1. • CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-5 CONFIDENTIAL Preparing for System Installation 7.3 7.3.1 Preparing for System Installation Pre-Installation Inspection Follow this procedure before installing Fusion equipment: 7.3.2 1. Verify the number of packages received against the packing list. 2. Check all packages for external damage; report any external damage to the shipping carrier. If there is damage, a shipping agent should be present before you unpack and inspect the contents because damage caused during transit is the responsibility of the shipping agent. 3. Open and check each package against the packing list. If any items are missing, contact LGC Wireless customer service (refer to Section 7.2.2 on page 7-4). 4. If damage is discovered at the time of installation, contact the shipping agent. Installation Checklist Table 7-2 Installation Checklist Installation Requirement Consideration Floor Plans Installation location of equipment clearly marked System Design Used to verify frequency bands after installation Power available: Fusion Main Hub (AC) Fusion Expansion Hub (AC) To RAU (DC) Hub’s power cord is 2 m (6.5 ft) long. 115/230V, 2/1A, 50–60 Hz 115/230V, 6/3A, 50-60 Hz 54V (from the Hub) Rack space available (Main and Expansion Hub) 89 mm (3.5 in.) high (2U) Wallmount Fusion Main Hub Hub must be mounted on 3/4” plywood backboard. Clearance for air circulation: Fusion Main or Expansion Hub RAU 76 mm (3 in.) front and rear, 51 mm (2 in.) sides 76 mm (3 in.) all around Suitable operating environment: Fusion Main or Expansion Hub RAUs Indoor location only 0° to +45°C (+32° to +113°F) 5% to 95% non-condensing humidity –25° to +45°C (–13° to +113°F) 5% to 95% non-condensing humidity Donor Antenna-to-Fusion Configuration (for each Fusion Band) Donor Antenna Installed, inspected; N-male to N-male coaxial cable to lightning arrestor/surge suppressor Lightning Arrestor or Surge Suppressor Installed between roof-top antenna and repeater; N-male to N-male 50 Ohm coaxial cable and outdoor cables longer than 140 feet. Repeater Installed between lightning arrestor/surge suppressor and Hub; N-male to N-male coaxial cable. The Repeater must be a UL listed product. 7-6 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Preparing for System Installation Table 7-2 Installation Checklist (continued) Installation Requirement Consideration Attenuator Installed between the circulator and the Hub downlink port to prevent overload. Optionally, it may be installed between the uplink port and the circulator. Circulator or Duplexer Installed between the repeater and the Hub uplink and downlink ports Base Station-to-Fusion Configuration (for each Fusion Band) Base Station Installed, inspected; verify RF power (see tables in Section 6.3 on page 6-4); N-male to N-male coaxial cable Attenuator Attenuation may be required to achieve the desired RF output at the RAU, and the desired uplink noise floor level Circulator or Duplexer When using a duplex BTS: Installed between the BTS and the Hub uplink and downlink ports. Not used with a simplex BTS Connecting Multiple Fusion Main Hubs Together 5-port Alarm Daisy-Chain Cable (PN 4024-3) For contact alarm monitoring of fault and warning alarms. Used to feed the alarms from multiple Fusion Main Hubs into a BTS or MetroReach Focus. N.C. Operation. Cabling Coaxial: repeater, base station, Smart Source to Fusion Main Hub Coax approved; N-type male connectors. Coaxial: RAU to passive antennas Use low-loss cable; N male connector; typical 1 m (3.3 ft) using RG142 coaxial cable. Fiber: Main Hub to Expansion Hubs SC/APC (angle-polished) male connectors for entire fiber run (can use SC/APC pigtails, PN 4012SCAPC-10 for MMF or 4013SCAPC-10 for SMF); Use jumper fiber cables for collocated Main and Expansion Hubs (3 m/10 ft.): Multi-mode: PN 401SCAPC-10 Single-mode: PN 4018SCAPC-10 Distance limited by optical loss of 3 dB Multi-mode up to 500 m (1640 ft.) Single-mode up to 6 km (19,685 ft.) CATV TIA-570-B approved; centerpin F male connectors. CATV cable must be screened and it must be grounded at both connector ends. The RAU will be damaged if it is mis-wired. Tie-off cables to avoid damaging the connectors because of cable strain. Fusion Expansion Hub to RAUs • Minimum: 0 meters (0 ft) • Maximum: RG-59: 150 meters (472 ft) * RG-8: 170 meters (558 ft) RG-11: 275 meters (902 ft) * Refer to Appendix A for CATV cable requirements. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-7 CONFIDENTIAL Preparing for System Installation Table 7-2 Installation Requirement Installation Checklist (continued) Consideration Configuring the System PC/laptop running standard browser software Refer to the AdminBrowser User Manual (PN D-620607-0020) Miscellaneous Cross-over Ethernet cable Male connectors; Fusion Main Hub to a PC/laptop running a standard browser to the Fusion AdminBrowser software; local connection or LAN switch connector for remote connections. Straight-through cable Female/male connectors; Fusion Main Hub to a modem for a remote connection. Distances Fusion Main Hub is within 3–6m (10–20 ft) of connecting repeater/BTS/MetroReach 7.3.3 If longer distance, determine the loss of the cable used for this connection and adjust the RF signal for each Band into the Fusion Main Hub accordingly. This can be done by readjusting the power from the base station, or by changing the attenuation value between the base station/repeater and the Hub Bands (1 and 2). Tools and Materials Required Table 7-3 Tools and Materials Required for Component Installation Description Cable ties Screwdriver Mounting screws and spring nuts Screws, anchors (for mounting RAUs) Drill Fiber connector cleaning kit Fusion splicer Splicing tool kit (including snips, cladding strippers, fiber cleaver, isopropyl alcohol, lint-free wipes) Fusion splicing sleeves 7-8 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Preparing for System Installation 7.3.4 Optional Accessories Table 7-4 Optional Accessories for Component Installation Description Wall-mount bracket (PN 4712) When using this bracket with an Fusion Main Hub, the Hub’s mounting bracket must be moved to the alternate mounting position (refer to the procedure on page page 7-11). Cable management (Cable manager: PN 4759; Tie wrap bar: PN 4757) Splice trays Pigtails with SC/APC connectors, 3 m (10 ft.) Multi-mode fiber SC/APC pigtail: PN 402SCAPC-10 Single-mode fiber SC/APC pigtail: PN 4013SCAPC-10 Jumper cable when Main and Expansion Hubs are collocated, 3 m (10 ft.) Multi-mode fiber SC/APC: PN 4018SCAPC-10 Teltone Line Sharing Switch (M-394-B-01) When using a single POTS line with multiple Fusion Main Hub/Modems: Connect up to four modems to a line sharing switch; switches can be cascaded to accommodate up to 16 modems per POTS line Alarm Cables: 5-port Alarm Daisy-Chain Cable (PN 4024-3) Alarm Sense Adapter Cable (PN 4025-1) Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-9 CONFIDENTIAL Fusion Installation Procedures 7.4 Fusion Installation Procedures The following procedures assume that the system is new from the factory and that it has not been programmed with bands. If you are replacing components in a pre-installed system with either new units or units that may already be programmed (for example, re-using units from another system), refer to Section 8. • Installing a Fusion Main Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 • Installing a Fusion Main Hub in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 • Using the Wall Rack-Mounting Option . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13 • Installing an Optional Cable Manager in the Rack . . . . . . . . . . . . . . . . . . 7-12 • Installing a Main Hub Using the 12” Wall-Mounted Rack (PN 4712) . . . 7-12 • Installing a Fusion Main Hub Directly to the Wall . . . . . . . . . . . . . . . . . . 7-14 • Connecting the Fiber Cables to the Main Hub . . . . . . . . . . . . . . . . . . . . . . 7-15 • Powering On the Main Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-18 • Installing Expansion Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-20 • Installing an Expansion Hub in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-20 • Installing an Expansion Hub Using the 12” Wall-Mounted Rack . . . . . . . 7-21 • Installing a Fusion Expansion Hub Directly to the Wall . . . . . . . . . . . . . . 7-22 • Installing an Optional Cable Manager in the Rack . . . . . . . . . . . . . . . . . . 7-23 • Powering On the Expansion Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23 • Connecting the Fiber Cables to the Expansion Hub . . . . . . . . . . . . . . . . . . 7-24 • Connecting the 75 Ohm CATV Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25 • Troubleshooting Expansion Hub LEDs During Installation . . . . . . . . . . . 7-26 • Installing RAUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27 • Installing RAUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27 • Installing Passive Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27 • Connecting the Antenna to the RAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-29 • Connecting the CATV Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-29 • Troubleshooting Using RAU LEDs During Installation . . . . . . . . . . . . . . 7-30 • Installing RAUs in a Multiple Operator System . . . . . . . . . . . . . . . . . . . . 7-31 • Configuring the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31 • Connecting the PC to the Fusion Main Hub to Run AdminBrowser . . . . . 7-31 • Programming the Fusion Main Hub Using AdminBrowser . . . . . . . . . . . . 7-32 • Fusion Splicing of Fiber and Pigtail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-37 7-10 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures The following procedures assume that the system is installed and programmed. • Interfacing the Fusion Main Hub to an RF Source . . . . . . . . . . . . . . . . . . . . . 7-39 • Connecting a Single Fusion Main Hub to an RF Source . . . . . . . . . . . . . . 7-39 • Connecting a Fusion Main Hub to a Roof-top Antenna . . . . . . . . . . . . . . . 7-43 • Connecting Multiple Fusion Main Hubs to an RF Source . . . . . . . . . . . . . 7-44 • Connecting Multiple Fusion Main Hubs to a Duplex Repeater or BTS . . 7-47 • Connecting Contact Alarms to a Fusion System . . . . . . . . . . . . . . . . . . . . . . . 7-49 • Alarm Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-50 • Alarm Sense . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-53 • Alarm Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-55 • Alarm Monitoring Connectivity Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-57 • Direct Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-57 • Modem Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-58 • 100 BASE-T Port Expander Connection . . . . . . . . . . . . . . . . . . . . . . . . . . 7-67 • POTS Line Sharing Switch Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-68 • Ethernet LAN Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-70 • SNMP Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-71 7.4.1 Installing a Fusion Main Hub CAUTION: Install Fusion Main Hubs in indoor locations only. Installing a Fusion Main Hub in a Rack The Fusion Main Hub (2U high) mounts in a standard 19 in. (483 mm) equipment rack. Allow clearance of 76 mm (3 in.) front and rear, and 51 mm (2 in.) on both sides for air circulation. No top or bottom clearance is required. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-11 CONFIDENTIAL Fusion Installation Procedures Figure 7-1 Flush Mounting Bracket Detail Consideration: • The Fusion Main Hub is shipped with #10-32 mounting screws. Another common rack thread is #12-24. Confirm that the mounting screws match the rack’s threads. To install the Hub in a rack: 1. Insert spring nuts into rack where needed or use existing threaded holes. 2. Place the Hub into the rack from the front. 3. Align the flange holes with the spring nuts installed in Step 1. 4. Insert the mounting screws in the appropriate positions in the rack. 5. Tighten the mounting screws. Installing an Optional Cable Manager in the Rack • Using the screws provided, fasten the cable manager to the rack, immediately above or below the Main Hub. Installing a Main Hub Using the 12” Wall-Mounted Rack (PN 4712) Considerations: • The rack-mounting brackets on the Fusion Main Hub must be moved to the recessed mounting position (shown in Figure 7-2) to allow for the required 76 mm (3 in.) rear clearance. 7-12 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures • The maximum weight the bracket can hold is 22.5 kg (50 lbs). • The bracket is designed to accommodate a Fusion Main Hub (12 lbs.) or an Expansion Hub (14.5 lbs.). • The wall mount bracket should be securely mounted to wall, using the four key slot mounting holes on the bracket. Using the Wall Rack-Mounting Option You can flip the rack mounting brackets, as shown in Figure 7-2, so the hub can be mounted 76 mm (3 in.) forward in the rack. Figure 7-2 Bracket Detail For Wall Mount Rack (PN 4712) To install the Hub to the wall-mounted rack: 1. Attach the wall bracket (PN 4712) to wall the using #10 Pan Head wood screws, 1-1/2” minimum length for mounting in wood studs or 3/4“thick plywood. The bracket must be positioned so that the Hub will be in a horizontal position when it is installed. (Refer to Figure 7-2.) NOTE: If wall stud spacing of 16” is not available, LGC recommends that 3/4” plywood be pre-installed to the wall. You can then attach the bracket to the plywood using the wood screws. 2. Remove both of the rack mounting brackets from the Hub. 3. Reattach each of the rack mounting brackets to the recessed wall mount position. 4. Install the Hub in the rack using the rack mounting screws. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-13 CONFIDENTIAL Fusion Installation Procedures Installing a Fusion Main Hub Directly to the Wall To install the Hub directly to the wall: 1. Pre-install 3/4” plywood to the wall. 2. Mount both of the rack mounting brackets using #10-32 machine screws (refer to illustration Figure 7-4). 3. Attach the Hub to the wall so the mounting brackets are orientated at the top and bottom of the wall mounted hub. (Refer to Figure 7-3.) Figure 7-3 Installing Directly to the Wall Use two #10 Pan Head wood screws, 1-1/2” length, to secure each bracket to the plywood. In this orientation the enclosure fans shall face to the left. 7-14 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures Figure 7-4 Using Hub Rack-Mounting Brackets for Direct Wall Installation Connecting the Fiber Cables to the Main Hub Considerations: • Before connecting the fiber cables, confirm that their optical loss does not exceed the 3 dB optical budget. • If you are using fiber distribution panels, confirm that the total optical loss of fiber cable, from the Main Hub through distribution panels and patch cords to the Expansion Hub, does not exceed the optical budget. • Make sure the fiber cable’s connectors are SC/APC (angle-polished). Using any other connector type will result in degraded system performance and may damage the equipment. (You can use an SC/APC pigtail if the fiber cable’s connectors are not SC/APC. Refer to“Fusion Splicing of Fiber and Pigtail” on page 7-37. Or, you can change the fiber’s connector to SC/APC.) NOTE: Observe all Fiber Port Safety Precautions listed in Section 7.2.3 on page 7-5. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-15 CONFIDENTIAL Fusion Installation Procedures To clean the fiber ports: You can clean the Hub’s fiber ports using canned compressed air or isopropyl alcohol and foam tipped swabs. Considerations: • If using compressed air: • The air must be free of dust, water, and oil. • Hold the can level during use. • If using isopropyl alcohol and foam tipped swabs: • Use only 98% pure or more alcohol Procedure using compressed air: 1. Remove the port’s dust cap. 2. Spray the compressed air away from the unit for a few seconds to clean out the nozzle and then blow dust particles out of each fiber port. Procedure using isopropyl alcohol: 1. Remove the connector’s dust cap. 2. Dip a 2.5mm lint-free, foam-tipped swab in isopropyl alcohol and slowly insert the tip into the connector. 3. Gently twist the swab to clean the port. 4. Insert a dry swab into the port to dry it. Additionally, you can use compressed air after the alcohol has completely evaporated. To clean the fiber ends: Be sure that the fiber cable’s SC/APC connectors are clean and free of dust and oils. You need lint-free cloths, isopropyl alcohol, and compressed air 1. Moisten a lint-free cloth with isopropyl alcohol. 2. Gently wipe the fiber end with the moistened cloth. 3. Using a dry lint-free cloth, gently wipe the fiber end. 4. Spray the compressed air away from the connector for a few seconds to clean out the nozzle and then use it to completely dry the connector. To test the fiber cables: Perform cable testing and record the results. Test results are required for the final As-Built Document. To connect the fiber cables: The fiber cable is labeled with either 1 or 2, or is color-coded. In addition to these labels, you should add a code that identifies which port on the Main Hub is being 7-16 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures used and which Expansion Hub the cables are intended for. This differentiates the connectors for proper connection between the Main Hub and Expansion Hubs. For example: First pair to Main Hub port 1: 11 (uplink), 12 (downlink); Second pair to Main Hub port 2: 21 (uplink), 22 (downlink); Third pair to Main Hub port 3: 31 (uplink), 32 (downlink); and so on. If the fiber jumper is labeled with 1 or 2: 1. Connect 1s to UPLINK ports on the Main Hub. 2. Connect 2s to DOWNLINK ports on the Main Hub. 3. Record which cable number and port number you connected to UPLINK and DOWNLINK. This information is needed when connecting the other end of the fiber cable to the Expansion Hub’s fiber ports. The fiber port LEDs should be off, indicating that the Expansion Hub(s) are not connected. If the fiber jumper is color-coded (for example, “blue” or “red”): 1. Connect “blue” to UPLINK ports on the Main Hub. 2. Connect “red” to DOWNLINK ports on the Main Hub. 3. Record which color and port number you connected to UPLINK and DOWNLINK. This information is needed when connecting the other end of the fiber cable to the Expansion Hub’s fiber ports. The fiber port LEDs should be off, indicating that the Expansion Hub(s) are not connected. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-17 CONFIDENTIAL Fusion Installation Procedures Powering On the Main Hub 1. Connect the AC power cord to the Main Hub. 2. Plug the power cord into an AC power outlet. 3. Turn on the power to the Main Hub and check that all the LED lamps are functioning properly. Upon power-up, the LEDs blinks for five seconds as a visual check that they are functioning. After the five-second test: LED states during power on will vary, depending on whether Expansion Hubs are connected. Refer to Table 7-5 for possible combinations. Table 7-5 During Installation Power On 1. Main Hub power is On with no Expansion Hubs connected. LED State Action Impact POWER Off Check AC power; check that the Main Hub power-on switch is on; replace the Main Hub The Main Hub is not powering on. POWER Red Replace the Main Hub The power supply is out-of-specification. PORT LEDs are on but they didn’t blink through all states Replace the Main Hub. The micro controller is not resetting properly; flash memory corrupted. PORT Red The port is unusable; replace the Main Hub when possible. Fiber sensor fault, do not use the port. Off 7-18 CONFIDENTIAL Troubleshooting Main Hub LEDs During Installation InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures Table 7-5 During Installation Power On 2. Main Hub power is On with Expansion Hubs connected and powered on. Troubleshooting Main Hub LEDs During Installation (continued) LED State Action Impact PORT Off • If the port LEDs do not illuminate, check the fiber uplink for excessive optical loss. • If Expansion Hub’s DL STATUS LED is red: • Verify that the fiber is connected to the correct port (that is, uplink/downlink) • Swap the uplink and downlink cables. • Connect the fiber pair to another port. If the second port’s LEDs do not illuminate Green/Red, replace the Main Hub. • If the second port works, flag the first port as unusable; replace the Main Hub when possible. No uplink optical power, the Expansion Hub is not recognized as being present. PORT Red (60 ppm) • If the Expansion Hub DL STATUS LED is red, check the downlink fiber cable for excessive optical loss. • Connect the fiber pair to another port. If the second port’s LEDs do not illuminate Green/Red, replace the Main Hub. • If the second port works, flag the first port as unusable; replace the Main Hub when possible. No communication with the Expansion Hub. PORT Red The Expansion Hub or connected RAU reports a fault The Expansion Hub or one or more RAUs are off-line. Use AdminManager to determine the problem. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A No communication with the Expansion Hub. 7-19 CONFIDENTIAL Fusion Installation Procedures 7.4.2 Installing Expansion Hubs The Expansion Hub (2U high) can be installed in a standard 19 in. (483 mm) equipment rack or in a wall-mountable equipment rack that is available from LGC Wireless. Allow a clearance of 76 mm (3 in.) front and rear and 51 mm (2 in.) sides for air circulation. No top and bottom clearance is required. CAUTION: Install Expansion Hubs in indoor locations only. Installing an Expansion Hub in a Rack Consideration: • The Expansion Hub is shipped with #10-32 mounting screws. Another common rack thread is #12-24. Confirm that the mounting screws match the rack’s threads. Figure 7-5 Flush Mounting Bracket Detail To install the hub in a rack: 7-20 CONFIDENTIAL 1. Insert spring nuts into the rack where needed or use existing threaded holes. 2. Place the Expansion Hub into the rack from the front. 3. Align the flange holes with the spring nuts installed in Step 1. 4. Insert the mounting screws in the appropriate positions in the rack. 5. Tighten the mounting screws. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures Installing an Expansion Hub Using the 12” Wall-Mounted Rack Considerations: • The rack (PN4712) is 305 mm (12 in.) deep. The Expansion Hub is 381 mm (15 in.) deep. You must move the rack mounting brackets on the Expansion Hub, as shown in Figure 7-6) to the center mounting position to allow for the 76 mm (3 in.) rear clearance that is required. • The maximum weight the rack can hold is 22.5 kg (50 lbs). Figure 7-6 Bracket Detail For Wall Mount Rack (PN 4712) To install the hub in a wall-mounted rack: 1. Attach the equipment rack to the wall using the screws that are provided. The rack must be positioned so that the Expansion Hub will be in a horizontal position when it is installed. NOTE: If wall stud spacing of 16” is not available, LGC recommends that 3/4” plywood be pre-installed to the wall. You can then attach the bracket to the plywood using the wood screws. 2. Remove both of the rack mounting brackets from the Hub. 3. Reattach each of the rack mounting brackets to the recessed wall mount position (Figure 7-6). 4. Install the Hub in the rack using the rack mounting screws. 5. Tighten the mounting screws. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-21 CONFIDENTIAL Fusion Installation Procedures Installing a Fusion Expansion Hub Directly to the Wall To install the Hub directly to the wall: 1. Pre-install 3/4” plywood to the wall. 2. Mount both of the rack mounting brackets using #10-32 machine screws (refer to illustration Figure 7-7). 3. Attach the Hub to the wall so the mounting brackets are orientated at the top and bottom of the wall mounted hub. (Refer to Figure 7-8.) Figure 7-7 7-22 CONFIDENTIAL Using Hub Rack-Mounting Brackets for Direct Wall Installation InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures Figure 7-8 Installing Directly to the Wall NOTE: Leave the dust caps on the fiber ports until you are ready to connect the fiber optic cables. Installing an Optional Cable Manager in the Rack • Using the screws provided, fasten the cable manager to the rack, immediately above or below the Expansion Hub. Powering On the Expansion Hub 1. Connect the AC power cord to the Expansion Hub. 2. Plug the power cord into an AC power outlet. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-23 CONFIDENTIAL Fusion Installation Procedures 3. Turn on the power to the Expansion Hub and check that all the LED lamps are functioning properly. Upon power-up, the LEDs blinks for five seconds as a visual check that they are functioning. After the five-second test: • The POWER and UL STATUS LEDs should be green. – If the uplink fiber is not connected, the UL STATUS LED turns red indicating that there is no communication with the Main Hub. • The E-HUB STATUS and DL STATUS LEDs should be red. • All port LEDs should be off because no RAUs are connected yet. Connecting the Fiber Cables to the Expansion Hub Considerations: • Before connecting the fiber cables, confirm that their optical loss does not exceed 3 dB optical budget. RL is less than -60dB. • If fiber distribution panels are used, confirm that the total optical loss of fiber cable, from the Main Hub through distribution panels and patch cords to the Expansion Hub, does not exceed the optical budget. • Make sure the fiber cable’s connectors are SC/APC (angle-polished).Using any other connector type will result in degraded system performance and may damage the equipment. (You can use an SC/APC pigtail if the fiber cable’s connectors are not SC/APC, refer to “Fusion Splicing of Fiber and Pigtail” on page 7-37, or replace the connectors.) NOTE: Observe all Fiber Port Safety Precautions listed in Section 7.2.3 on page 7-5. To connect the fiber cables: The fiber cable is labeled with either 1 or 2, or is color-coded. For proper connection between the Main Hub ports and the Expansion Hub ports, refer to the numbering or color-coded connections you recorded when installing the Main Hub(s). If the fiber jumper is labeled with 1 or 2: 1. Connect 2 to DOWNLINK on Expansion Hub. The DL STATUS LED should turn green as soon as you connect the fiber. If it does not, there is a downlink problem. Make sure you are connecting the correct cable to the port. 2. Connect 1 to UPLINK on Expansion Hub. The UL STATUS LED turns green on the first Main Hub communication. It may take up to 20 seconds to establish communication. The Expansion Hub’s E-HUB STATUS LED turns green when the Main Hub sends it the frequency band command. 7-24 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures If the UL STATUS and E-HUB STATUS LEDs do not turn green/green, check the Main Hub LEDs. Refer to page 7-18, item 2 in Table 7-5. If the fiber jumper is color-coded (for example, “blue” or “red”): 1. Connect “red” to DOWNLINK on Expansion Hub. The DL STATUS LED should turn green as soon as you connect the fiber. If it does not, there is a downlink problem. Make sure you are connecting the correct cable to the port. 2. Connect “blue” to UPLINK on Expansion Hub. The UL STATUS LED turns green on the first Main Hub communication. It may take up to 20 seconds to establish communication. The Expansion Hub’s E-HUB STATUS LED turns green when the Main Hub sends it the frequency band command. If the UL STATUS and E-HUB STATUS LEDs do not turn green/green, check the Main Hub LEDs. See page 7-18, item 2 in Table 7-5. Connecting the 75 Ohm CATV Cables Considerations: • Verify that the cable has been tested and the test results are recorded. This information is required for the As-Built Document. • Verify that only captive centerpin F connectors are used on the solid copper center conductor CATV cable from CommScope (or equivalent). • Verify that the CATV cable is labeled with: • Fusion Expansion Hub port number being used • RAU identifier • Carrier (for multiple operator systems) To connect the CATV cables: 1. Connect the CATV cables to the F ports according to the labels on the cables. The STATUS LEDs should be off because the RAUs are not connected at the other end of the CATV cable. 2. Record which cable you are connecting to which port (that is, from the label on the cable). This information is required for the As-Built Document. 3. Tie-off the cables or use the optional cable manager to avoid damaging the connectors because of cable strain. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-25 CONFIDENTIAL Fusion Installation Procedures Troubleshooting Expansion Hub LEDs During Installation • All Expansion Hub PORT LEDs with RAUs connected should indicate Green/Red. This indicates that the RAU is powered on and communication has been established. • The Expansion Hub UL STATUS LED should be Green. Table 7-6 Troubleshooting Expansion Hub LEDs During Installation During Installation LED State Action Impact 1. Expansion POWER Off Check AC power; make sure the Expansion Hub power-on switch is on; replace the Expansion Hub. The Expansion Hub is not powering on. PORT LEDs are on but didn’t blink through all states. Replace the Expansion Hub. The Microcontroller is not resetting properly; flash memory corrupted. PORT Flashing Red (6 PPM) Port unusable; replace the Expansion Hub when possible. Current sensor fault; do not use the port. UL STATUS Red, after power-up blink Replace the Expansion Hub. The Expansion Hub laser is not operational; no uplink between the Expansion Hub and Main Hub. UL STATUS Red Check the Main Hub LEDs Refer to page 7-18, item 2 in Table 7-5. No communication with Main Hub. Hub power is On and no RAUs are connected Use AdminBrowser to determine the problem. DL STATUS Red Check the downlink fiber for optical power; verify that the cables are connected to correct ports (that is, uplink/downlink) No downlink between the Expansion Hub and Main Hub. Check the Main Hub LEDs. Refer to page 7-18, item 2 in Table 7-5. 2. Expansion PORT Off Check the CATV cable. Hub power is On and RAUs are connected Power is not getting to the RAU. PORT Flashing Red (60 PPM) Test the CATV cable. If the cable tests OK, try another port. If the second port’s LEDs are Red/Off, replace the RAU. If the second RAU doesn’t work; replace the Expansion Hub. Power levels to RAU are not correct; communications are not established. Use AdminBrowser to determine the problem. RAU is off-line. PORT 7-26 CONFIDENTIAL Red If the second port works, flag the first port as unusable; replace EH when possible. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures 7.4.3 Installing RAUs CAUTION: Install RAUs in indoor locations only. Do not connect an antenna that is installed in an outdoor location to an RAU. For outdoor installations, a protective enclosure is required. Installing RAUs Mount all RAUs in the locations marked on the floor plans. Considerations: • Install 800 iDEN and 850/1900 MHz RAUs so that their antennas will be separated by enough space to reduce signal interference between the 800 and 850 bands. Refer to Section , “800/850 MHz Isolation Requirements,” on page 7-27 for recommended distance between antennas. • You can place the unit, without its fastening hardware, on a flat surface, such as a shelf, desk, cabinet, or any other horizontal surface that allows stable placement with the mounting base facing down to the mounting surface. For mounting to other locations (that is, walls, ceilings, poles) the RAU must be securely mounted using the 4 slotted mounting holes provided with #6 diameter fasteners. This method of mounting must securely hold a minimum of 7 lbs. load. • Attach the RAU securely to a stationary object (that is, a wall, pole, or ceiling tile). • For proper ventilation: • Keep at least 76 mm (3 in.) clearance around the RAU to ensure proper venting. • Do not stack RAUs on top of each other. • Always mount the RAU with the solid face (containing the mounting holes) against the mounting surface. Installing Passive Antennas Refer to the manufacturer’s installation instructions to install passive antennas. Location Passive antennas are usually installed below the ceiling. If they are installed above the ceiling, you must consider the additional loss due to the ceiling material when estimating the antenna coverage area. 800/850 MHz Isolation Requirements When deploying any RF system, give special attention to preventing receiver blocking or desensitization by out-of-band transmitters. Typically, sharp filters in the receiver front-end will reduce the interfering transmitters to tolerable levels. In select cases, the interferers may occupy a frequency band that is directly adjacent to the receiving band and cannot be adequately rejected by filtering. The only recourse in Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-27 CONFIDENTIAL Fusion Installation Procedures these situations is to provide sufficient isolation by physically separating the interfering transmitters and receivers. iDEN occupies spectrum at both 800 MHz and 900 MHz (Tx:806–825/Rx:851–870 and Tx:896–901/Rx:935–940), while the Cellular A and B carriers share a single 850 MHz block (Tx:869–894/Rx:824–849). The combination of these frequency bands, 800/900 MHz iDEN and 850 MHz Cellular, result in uplink (BTS receive) bands that are adjacent to downlink (BTS transmit) bands. Figure 7-9 depicts these nearly contiguous bands, with arrows indicating the interfering downlink and receiving uplink bands. Figure 7-9 800/850 MHz Spectrum 850 850 Installation of an in-building distributed antenna system (DAS) to provide coverage for both 800/900 MHz iDEN and 850 MHz Cellular must account for these downlink-to-uplink interference issues and provide adequate isolation. LGC offers the following guidelines toward achieving the proper amount of isolation when deploying LGC Wireless Unison DAS products. Figure 7-10 Guideline for Unison RAU Antenna Placement FSN-809019-1 RAU 850 Cellular MHub 850 Cellular EHub 850 Cellular RAU FSN-8519-1 RAU 800 MHz iDEN Downlink and 850 MHz Cellular Uplink A 2 MHz frequency gap (851 – 849 MHz) separates the 800 iDEN downlink and 850 Cellular uplink frequency bands. Because of this narrow spacing, 800 iDEN downlink intermodulation products may fall within the 850 Cellular uplink band. In addition, 800 iDEN downlink signals near the lower edge of the band at 851 MHz may 7-28 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures cause the 850 Cellular uplink automatic level control (ALC) circuitry in the RAU to engage and thereby reduce uplink gain. To prevent either of these conditions, use the following guidelines: • In-band 800 iDEN intermodulation products < -90dBm • Lower frequency 800 iDEN signals < –30dBm for Fusion Given a typical DAS configuration (4 iDEN carriers, omni-directional antennas, line of sight), these guidelines translate to an antenna spacing (d1) of 6 – 9 meters. 850 MHz Cellular Downlink and 900 MHz iDEN Uplink A 2 MHz frequency gap (896 – 894 MHz) separates the 850 Cellular downlink and 900 iDEN uplink frequency bands. Because of this narrow spacing, 850 Cellular downlink intermodulation products may fall within the 900 iDEN uplink band. In addition, 850 Cellular downlink signals near the upper edge of the band at 894 MHz may cause the 900 iDEN uplink ALC to engage and thereby reduce uplink gain. To prevent either of these conditions, use the following guidelines: • In-band 850 Cellular intermodulation products < -90dBm • Upper frequency 850 Cellular signals < –30dBm for Fusion Given a typical DAS configuration (6 CDMA carriers for Fusion, omni-directional antennas, line of sight), these guidelines translate to an antenna spacing (d2) of 8-14 meters. Spacing between RAUs FSN-8519-1 and FSN-809019-1 should be in a range of from 8 to 14 meters. Connecting the Antenna to the RAU Connect a passive multi-band antenna to the N connector on the RAU using coaxial cable with the least amount of loss possible. CAUTION: Firmly hand-tighten the N connector – DO NOT over-tighten the connector. Connecting the CATV Cable Considerations: • Verify that the cable has been tested and the test results are recorded. This information is required for the As-Built Document. • Verify that only captive centerpin 75 Ohm Type-F connectors are used on the solid copper center conductor CATV 75 Ohm cable. • Verify that the CATV cable is labeled with: Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-29 CONFIDENTIAL Fusion Installation Procedures • Fusion Main Hub port number being used • RAU identifier • Carrier (for multiple operator systems) To connect the CATV cable: 1. Connect the CATV cables to the F female port on the RAU according to the label on the cable. Power is supplied by the Fusion Main Hub over the CATV cable conductors. Upon power up, the LEDs will blink for two seconds as a visual check that they are functioning. After the two-second test: • The LINK LED should be green indicating it is receiving power and communications from the Fusion Main Hub. • The ALARM LED should be red until the Fusion Main Hub issues the band command, within about 20 seconds, then it should be green. 2. Record which cable you are connecting to the RAU (from the label on the cable). This information is required for the As-Built Document. 3. 7.4.3.1 Tie-off cables or use the optional cable manager to avoid damaging the connectors because of cable strain. Troubleshooting Using RAU LEDs During Installation • The LINK LED should be green and remain green for longer than 90 seconds. The ALARM LEDs are red when the system band has not been programmed. Table 7-7 During Installation The RAU is connected to the Fusion Expansion Hub, which is powered on 7-30 CONFIDENTIAL Troubleshooting RAU LEDs During Installation LED State Action Impact LINK Off Check CATV cable. No power to the RAU. ALARM Off LINK Green Red • Check CATV cable • Check Hub LEDs Refer to page 7-26, item 2 in Table 7-6. • Use AdminBrowser to determine the problem. The RAU is off-line. ALARM LINK Red from green, after cables are connected for 60 seconds • Check CATV cable. • Check the Hub LEDs. • Use AdminBrowser to determine the problem. No communications between the RAU and the Hub. ALARM Red InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures 7.4.3.2 Installing RAUs in a Multiple Operator System When installing both iDEN and Cellular systems in parallel, either as dual-band or multiple operator systems, you must take special provision to assure that the individual RAUs do not interfere with each other. The 850/1900 MHz and 800/900/1900 MHz RAU’s antennas must be separated by at least 8 meters (26 feet) to assure that the iDEN downlink signals do not interfere with the Cellular uplink signals. 7.4.4 Configuring the System Before the system can operate properly, use AdminBrowser to program the Fusion Main Hub with the frequency bands that are to be distributed. The Hub must be programmed with the same frequencies as the RAU used. NOTE: The frequency bands should automatically be set on power up and this step should not be required. Considerations: • The AdminBrowser software, described in the AdminBrowser User Manual (PN D-620607-0-20), must be running on a PC/laptop. • Crossover Ethernet cable with male connectors required. Connecting the PC to the Fusion Main Hub to Run AdminBrowser 1. Connect the AC power cord to the Hub. Make sure the Hub is grounded through the ground lug on the AC power and the frame ground lug as required. The warranty does not cover damage caused when an ungrounded Hub is powered on. 2. Plug the power cord into an AC power outlet. 3. Verify that all cables are properly connected on the Hub. 4. Turn on the power to the Hub. All LEDs blink through the power up sequence. At each port where an RAU is detected (drawing current), the port LEDs lights green. The Fusion STATUS LED is orange during system boot and should turn green after about 90 seconds if it finds no faults. This state indicates the band’s are not programmed and provides feedback on the status of the RAU connections. The LEDs blink for 20 seconds as a visual check that they are functioning. 5. Connect the cross-over Ethernet cable to the PC/laptop and then to the RJ-45 on the Hub’s front panel. 100-BASE-T port Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-31 CONFIDENTIAL Fusion Installation Procedures Programming the Fusion Main Hub Using AdminBrowser • Connect the provided TCP/IP crossover cable to the laptop and then to the Admin/LAN RJ-45 port on the Fusion Main Hub’s front panel. • Turn on the laptop and start the Fusion Main Hub. Windows 2000 1. Right-click My Network Places and select Properties. 2. Highlight Internet Protocol (TCP/IP) and click Properties. A screen similar to the Figure 7-11 appears. Figure 7-11 7-32 CONFIDENTIAL Internet Protocol (TCP/IP) Properties Window 3. Make note of the current IP address, Subnet mask, and Default gateway, if they are configured. You will need to re-enter them after you have configured the Fusion Main Hub. 4. Select Use the following IP address. 5. Change the IP address to 192.168.0.101 6. Change the Subnet mask to 255.255.255.0 7. Change the Default gateway to 192.168.0.1 8. Click OK twice. You may be asked if you want to reboot your computer. If so, click Yes. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures Windows XP 1. Click Start>Settings>Network Connections>Local Area Connection. The window shown in Figure 7-12 appears. Figure 7-12 Local Area Connection Properties Window 2. In the This connection uses the following items, scroll down to and select Internet Protocol (TCP/IP) and click Properties. 3. Perform steps 3 through 8 in the preceding section. Using AdminBrowser 1. Launch your web browser, type Https://192.168.0.100 in the URL line, and click Go. 2. When AdminBrowser appears, log in using the default password: password. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-33 CONFIDENTIAL Fusion Installation Procedures 3. Click System Configuration and then click Set Date/Time. A page similar to Figure 7-13 appears. Figure 7-13 4. Enter the desired time and date in the format indicated on the page and click Set Date/Time. A page appears requiring you to reboot the system for the new date and time to take effect. 5. Select the Fusion Main Hub and click Install/Configure System. A screen similar to the Figure 7-14 appears. Figure 7-14 6. 7-34 CONFIDENTIAL Set Time and Date Window AdminBrowser Configuration Window If desired, type in a label. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Fusion Installation Procedures The label is the system name displayed next to the icons and used in messages.It can be up to 32 characters long depending upon the firmware version. The default system label is “Fusion” and will be used if you enter nothing. 7. Type in a Date and Time or leave the current system date and time unchanged. Enter time is a 24-hour format. 8. Use the next section to schedule a System Test. This section allows you to do the following: • Click the check box to enable this feature. • Click the check box to cause system test on power up. • Enter values to schedule the date and time of the next system test. • Enter values to specify the recurrence of the test by day or by week. Schedule System Test allows periodic, automatic execution of the system end-to-end test. Just like Perform System Test, a Schedule System Test suspends normal service for the duration of the test; calls are dropped, and no new calls can be established during the test. Test duration depends on the configuration (number of RAUs) and requires one or two minutes to complete. After completion of the system test, the scheduled system test time is updated to the next test time, and an event log entry is made. 9. Use the scroll bar on the left side of the page to scroll down to view the rest of the page as shown in Figure 7-15. Figure 7-15 10. AdminBrowser Configuration Window (continued) In the Band area, do the following: Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-35 CONFIDENTIAL Fusion Installation Procedures • You should not have to select the bands. The system self configures the band by validating that all the RAUs connected are the same type. • Use the pull-down to specify the Uplink and Downlink gain for each band. You can set system gain within the specified range in 1 dB increments. • Use the pull-down to set the Uplink Automatic Level Control to either “Single” or “Multiple” for each band in the system. (The default is “Multiple.” 11. In the Input/Output Alarms area, do the following for each Alarm Sense: • Enable each Alarm Sense by using the check box. • Use the pull-down to set the Normal State to Closed or Opened. (The default is “Closed.” • Assign a label to each alarm sense. 12. When you have completed inputting the desired information, click Install System to configure the system. During configuration all disconnect statuses are cleared for attached RAUs; the frequency band, gain, and system label are set; logs are cleared; the system test is performed; and finally the system tree is refreshed. The icons should be: Indicating that the band is correctly set. Indicating that communications are OK. If there are problems, the icons will be different and a message is displayed in the Messages pane. 13. Connect the Main Hub to the RF source (for example, BTS or BDA). Do not exceed the maximum input RF power (1 Watt) to the Fusion Main Hub. Exceeding the limit could cause permanent damage to the Hub. CAUTION:Only carriers and their approved installers or LGC-authorized installers are allowed to connect to the RF source. Serious damage to the equipment can occur if it is over-driven. The Fusion system should now be operational. Using a mobile phone, walk your site and test the signal strength. 14. Make sure to change the TCP/IP setting in your laptop back to their original values. NOTE: NOTE: LGC Wireless’ equipment is designed to operate in the licensed frequency bands of mobile, cellular, and PCS operators. In the USA, the EU, and most countries this equipment may only be used by the licensee, his authorized agents or those with written authorization to do so. Similarly, unauthorized use is illegal, and subjects the owner to the corre- 7-36 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Splicing Fiber Optic Cable sponding legal sanctions of the national jurisdiction involved. Ownership of LGC Wireless equipment carries no automatic right of use. 7.5 Splicing Fiber Optic Cable The fiber cable must have SC/APC connectors for the entire run. If it does not, you can splice a pigtail, which has SC/APC connectors, to the fiber cable. LGC offers two pigtails: one for single-mode fiber (PN 4013SCAPC-3) and one for multi-mode fiber (PN 4012SCAPC-3). LGC Wireless recommends fusion splices because they have the lowest splice loss and return loss. Mechanical splices have higher losses and higher back reflection than fusion splices and are not recommended. Using a fusion splicer involves fusing together two butted and cleaved ends of fiber. The fusion splicer aligns the fibers and maintains alignment during the fusion process. Fusion splices have very low loss (typically less than 0.05 dB) and very low back reflection (return loss). Fusion splices should be organized in a splice tray designed to store and protect the splices. Fusion Splicing of Fiber and Pigtail Before you begin, make sure the fusion splicer is set to the proper mode (that is, single- or multi-mode). To fusion splice the fiber optic cable to the SC/APC pigtail: Option A 1. Secure both the fiber cable and the SC/APC pigtail in a splice tray that is installed immediately adjacent to the Hub. 2. Prepare the fiber end by cutting back the polyethylene jacket, the kevlar or fiberglass strength members, the extruded coating, and the buffer coating in order to expose the “bare fiber” – cladding plus core. Ensure that sufficient slack is maintained in order to be able to reach the fusion splicer. 3. Clean the unclad fiber core using isopropyl alcohol and lint-free wipes. 4. Cleave the unclad fiber to the length prescribed by the fusion splicer’s specification sheets. 5. Repeat steps 2 through 4 for the SC/APC pigtail. 6. Pass the splice sleeve onto the fiber strand. 7. Position both fiber ends in the fusion splicer and complete splice in accordance with the fusion splicer’s operation instructions. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-37 CONFIDENTIAL Splicing Fiber Optic Cable 8. Ensure that the estimated loss for the splice as measured by the fusion splicer is 0.10 dB or better. 9. Slide the fusion splicing sleeve over the point of the fusion splice. 10. Place the sleeve and fused fiber into the fusion splicer’s heater. 11. Allow time for the splice sleeve to cure. 12. Return fiber splice to the splice tray, store the sleeve in a splice holder within the tray, and store excess cable length in accordance with the tray manufacture’s directions. After successfully testing the fiber, plug the SC/APC pigtail into the proper optical port on the Hub. To fusion splice the fiber optic cable to the SC/APC pigtail: Option B 1. Secure both the fiber cable and the SC/APC pigtail in a splice tray portion of a fiber distribution panel. 2. Prepare the fiber end by cutting back the polyethylene jacket, the kevlar or fiberglass strength members, the extruded coating, and the buffer coating in order to expose the “bare fiber” – cladding plus core. Ensure that sufficient slack is maintained in order to be able to reach the fusion splicer. 3. Clean the unclad fiber core using isopropyl alcohol and lint-free wipes. 4. Cleave the unclad fiber to the length prescribed by the fusion splicer’s specification sheets. 5. Repeat steps 2 through 4 for the SC/APC pigtail. 6. Pass the splice sleeve onto the fiber strand. 7. Position both fiber ends in the fusion splicer and complete splice in accordance with the fusion splicer’s operation instructions. 8. Ensure that the estimated loss for the splice as measured by the fusion splicer is 0.10 dB or better. 9. Slide the fusion splicing sleeve over the point of the fusion splice. 10. Place the sleeve and fused fiber into the fusion splicer’s heater. 11. Allow time for the splice sleeve to cure. 12. Return fiber splice to the splice tray, store the sleeve in a splice holder within the tray, and store excess cable length in accordance with the tray manufacture’s directions. 13. After successfully testing the fiber cable, plug the SC/APC pigtail into the back side of the SC/APC bulkhead in the Fiber Distribution Panel. Install a SC/APC patch cord between the front side of the SC/APC bulkhead and the proper optical port on the Hub. NOTE: Refer to Section 9 for troubleshooting. 7-38 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Interfacing the Fusion Main Hub to an RF Source 7.6 Interfacing the Fusion Main Hub to an RF Source WARNING: Only LGC personnel or LGC-authorized installation personnel should connect the Fusion Main Hub to its Band associated base station or repeater. Exceeding the maximum input power could cause failure of the Fusion Main Hub (refer to Section 5.2 on page 5-4 for maximum power specifications). If the maximum composite power is too high, attenuation is required. 7.6.1 Connecting a Single Fusion Main Hub to an RF Source The Fusion system supports three RF sources, one for Band 1, Band 2, and Band 3. This section explains how each Band can be connected to its associated RF source. Connecting a Fusion Main Hub to an In-Building BTS WARNING: Only LGC personnel or LGC-authorized installation personnel should connect the Fusion Main Hub to a base station or repeater. Exceeding the maximum input power could cause failure of the Fusion Main Hub (refer to Section 5.2 on page 5-4 for maximum power specifications). If the maximum composite power is too high, attenuation is required. CAUTION:The UPLINK and DOWNLINK ports cannot handle a DC power feed from the base station. If DC power is present, a DC block must be used or the hub may be damaged. Connecting a Simplex Base Station to a Fusion Main Hub RF Band: 1. Connect an N-male to N-male coaxial cable to the transmit simplex connector on the base station. 2. Connect the other end of the N-male to N-male coaxial cable to the DOWNLINK connector on the Hub for the corresponding Band 1, Band 2, or Band 3. 3. Connect an N-male to N-male coaxial cable to the receive simplex connector on the base station. 4. Connect the other end of the N-male to N-male coaxial cable to the UPLINK connector on the Hub for the corresponding Band 1, Band 2, or Band 3. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-39 CONFIDENTIAL Interfacing the Fusion Main Hub to an RF Source Figure 7-16 Simplex Base Station to a Fusion Main Hub Band 1 UL1 Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 N-male to N-male Coaxial Cable Insert attenuator, if needed Note: This applies to either Band 1, Band 2, and Band 3. Simplex Base Station Band 3 T1/E1 to Mobile Switching Center Connecting a Duplex Base Station to a Fusion Main Hub: When connecting to a duplex base station, use a circulator or duplexer between it and the Fusion Main Hub. You can insert attenuators between the circulator or duplexer and Hub as needed. 7-40 CONFIDENTIAL 1. Connect an N-male to N-male coaxial cable to the duplex connector on the base station. 2. Connect the other N-male connector or duplexer to a circulator. 3. Connect an N-male to N-male coaxial cable to the DOWNLINK connector on the Hub for Band 1, Band 2, and Band 3. 4. Connect the other end of the N-male coaxial cable to the transmit connector on the circulator. 5. Connect an N-male to N-male coaxial cable to the UPLINK connector on the Hub for Band 1, Band 2, and Band 3. 6. Connect the other end of the N-male coaxial cable to the receive connector on the circulator. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Interfacing the Fusion Main Hub to an RF Source Figure 7-17 Duplex Base Station to a Fusion Main Hub Band 1 UL1 Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 N-male to N-male Coaxial Cable Circulator Insert attenuator, if needed N-male to N-male Coaxial Cable Duplex Base Station Note: This applies to either Band 1, Band 2, Band 3. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A T1/E1 to Mobile Switching Center 7-41 CONFIDENTIAL Interfacing the Fusion Main Hub to an RF Source Connecting a Fusion Main Hub RF Band to Multiple BTSs WARNING: Only LGC personnel or LGC-authorized installation personnel should connect the Fusion Main Hub to a base station or repeater. Exceeding the maximum input power could cause failure of the Fusion Main Hub (refer to Section 5.2 on page 5-4 for maximum power specifications). If the maximum composite power is too high, attenuation is required. You can use power combiner/splitters to connect a Fusion Main Hub RF Band to multiple base stations, as shown in Figure 7-18. Figure 7-18 Connecting a Fusion Main Hub to Multiple Base Stations Band 1 Band 3 Band 2 UL1 UL3 UL2 AC Power Alarms DL2 DL1 N-male to N-male Coaxial Jumper Cables between Combiner/Splitter and Fusion Main Hub’s Uplink Port for each on Band 1, Band 2, or Band 3 2 x 1 Power Combiner/Splitter DL3 N-male to N-male Coaxial Jumper Cables between Combiner/Splitter and Fusion Main Hub’s Downlink Port for either Band 1, Band 2, or Band 3 2 x 1 Power Combiner/Splitter Insert attenuators, if needed N-male to N-male Coaxial Jumper Cable to Repeater or Base Station UL DL BTS 1 7-42 CONFIDENTIAL UL DL BTS 2 InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Interfacing the Fusion Main Hub to an RF Source Connecting a Fusion Main Hub to a Roof-top Antenna LGC Wireless recommends that you use a lightning arrestor or surge protector in a roof-top antenna configuration. Insert the lightning arrestor or surge protector between the roof-top antenna and the repeater connected to the Fusion Main Hub RF Band. 1. Connect an N-male to N-male coaxial cable to the roof-top antenna. 2. Connect the other end of the N-male to N-male coaxial cable to the grounded surge suppressor. 3. Connect an N-male to N-male coaxial cable to the grounded surge suppressor. 4. Connect the other end of the N-male to N-male coaxial cable to the repeater. 5. Connect an N-male to N-male coaxial cable to the repeater. 6. Connect the other end of the N-male to N-male coaxial cable to the circulator 1 connector. 7. Connect an N-male to N-male coaxial cable to the circulator 2 connector. 8. Connect the other end of the N-male to N-male coaxial cable to the DOWNLINK connector on the Hub for either Band 1, Band 2, or Band 3. Attenuation may be required to achieve the desired RF output at the RAU. 9. Connect an N-male to N-male coaxial cable to the circulator 3 connector. 10. Connect the other end of the N-male to N-male coaxial cable to the UPLINK connector on the Hub for either Band 1, Band 2, or Band 3. Figure 7-19 Connecting a Fusion Main Hub to a Roof-top Antenna Band 1 UL1 Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 Roof-top Antenna N-male to N-male Coaxial Cable Circulator Grounded Surge Suppressor N-male to N-male Coaxial Cables Repeater N-male to N-male Coaxial Cable Note: This applies to either Band 1, Band 2, or Band 3. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A Attenuator (optional) 7-43 CONFIDENTIAL Interfacing the Fusion Main Hub to an RF Source Connecting a Fusion Main Hub to MetroReach Focus Refer to the MetroReach Focus manual for information. 7.6.2 Connecting Multiple Fusion Main Hubs to an RF Source You can use power combiner/splitters as splitters to connect multiple Fusion Main Hubs in order to increase the total number of RAUs in a system. You can also use power combiner/splitters to combine base station channels in order to increase the number of RF carriers the system transports. Connecting Multiple Fusion Main Hubs to a Simplex Repeater or BTS WARNING: Only LGC personnel or LGC-authorized installation personnel should connect the Fusion Main Hub to a base station or repeater. Exceeding the maximum input power could cause failure of the Fusion Main Hub (refer to Section 5.2 on page 5-4 for maximum power specifications). If the maximum composite power is too high, attenuation is required. Considerations: • 2 hybrid power combiner/splitters; one for uplink and one for downlink (2x1 for two Fusion Main Hubs, 3x1 for three, 4x1 for four, and so on.) • 1 N-male to N-male coaxial jumper cable between each power combiner/splitter and the base station • 2 N-male to N-male coaxial jumper cables between each power combiner/splitter and each Fusion Main Hub RF Band (either Band 1 or Band 2) Procedure: 1. Connect the power combiner/splitters to the repeater or base station using N-male to N-male coaxial jumper cables: a. From the first power combiner/splitter to the repeater or base station UPLINK b. From the second power combiner/splitter to the repeater or base station DOWNLINK 2. 7-44 CONFIDENTIAL Connect the power combiner/splitters to the Hubs: a. From the first Hub’s UPLINK port (Band 1, Band 2, or Band 3) to the first power combiner/splitter b. From the first Hub’s DOWNLINK port (Band 1, Band 2, or Band 3) to the second power combiner/splitter c. From the second Hub’s UPLINK port (Band 1, Band 2, or Band 3) to the first power combiner/splitter d. From the second Hub’s DOWNLINK port (Band 1, Band 2, or Band 3) to the second power combiner/splitter InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Interfacing the Fusion Main Hub to an RF Source NOTE: Connections should not cross Bands. For example, all Band 1 connections should be made to the same hybrid power combiner/splitter connected to the repeater BTS that matches the Band 1 frequency. 3. Check Hub LEDs. After connecting and powering on the Hub, check all LEDs to ensure that the system is operating properly. Make sure the Hub is grounded. The warranty does not cover damage caused when an ungrounded Hub is powered on. NOTE: Use a 50 ohm terminator on any unused power combiner/splitter ports. Figure 7-20 shows how to connect two Main Hubs to a simplex repeater or base station. Connecting two Hubs increases the total number of supportable RAUs from 8 to 16. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-45 CONFIDENTIAL Interfacing the Fusion Main Hub to an RF Source Connecting Two Fusion Main Hub’s RF Band Ports to a Simplex Repeater or Base Station Figure 7-20 Band 1 UL1 Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 Band 1 UL1 Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 N-male to N-male Coaxial Jumper Cables between Combiner/Splitter and Fusion Main Hub’s Downlink Port for either Band 1, Band 2, Band 3 N-male to N-male Coaxial Jumper Cables between Combiner/Splitter and Fusion Main Hub’s Uplink Port for either Band, Band 2, Band 3 2 x 1 Power Combiner/Splitter N-male to N-male Coaxial Jumper Cable to Repeater or Base Station 7-46 CONFIDENTIAL 2 x 1 Power Combiner/Splitter N-male to N-male Coaxial Jumper Cable to Repeater or Base Station InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Interfacing the Fusion Main Hub to an RF Source Connecting Multiple Fusion Main Hubs to a Duplex Repeater or BTS WARNING: Only LGC personnel or LGC-authorized installation personnel should connect the Fusion Main Hub to a base station or repeater. Exceeding the maximum input power could cause failure of the Fusion Main Hub (refer to Section 5.2 on page 5-4 for maximum power specifications). If the maximum composite power is too high, attenuation is required. Considerations: • 2 hybrid power combiner/splitters; one for uplink and one for downlink (2x1 for two Fusion Main Hubs, 3x1 for three, 4x1 for four, and so.) • 2 N-male to N-male coaxial jumper cables to connect each Fusion Main Hub’s RF Band to the power combiner/splitters • 1 circulator • 1 N-male to N-male coaxial jumper cable between each circulator and the repeater or base station • 1 N-male to N-male coaxial jumper cable between each circulator and power combiner/splitter Procedure: 1. Connect the circulator to the repeater or base station using one N-male to N-male coaxial jumper cable. 2. Connect each power combiner/splitter to the circulator using one N-male to N-male coaxial jumper cable per combiner/splitter. 3. Connect the power combiner/splitter to the Hubs using N-male to N-male coaxial jumper cable: a. From the first Hub’s UPLINK (Band 1, Band 2, or Band 3) port to the first power combiner/splitter b. From the first Hub’s DOWNLINK (Band 1, Band 2, or Band 3) port to the second power combiner/splitter c. From the second Hub’s UPLINK (Band 1, Band 2, or Band 3) port to the first power combiner/splitter d. From the second Hub’s DOWNLINK (Band 1, Band 2, or Band 3) port to the second power combiner/splitter NOTE: Connections should not cross Bands. For example, all Band 1 connections should be made to the same hybrid power combiner/splitter connected to the repeater BTS that matches the Band 1 frequency. 4. Check Hub LEDs. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-47 CONFIDENTIAL Interfacing the Fusion Main Hub to an RF Source After connecting and powering on the Hub, check all LEDs to ensure that the system is operating properly. Make sure the Main Hub is grounded. The warranty does not cover damage caused when an ungrounded Hub is powered on. NOTE: Use a 50 ohm terminator on any unused power combiner/splitter ports. Figure 7-21 shows how to connect two Hubs to a duplex repeater or base station. You need to use one circulator and one more coaxial jumper cable, as shown. Connecting Two Fusion Main Hub’s RF Band Ports to a Duplex Repeater or Base Station Figure 7-21 Band 1 UL1 Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 Band 1 UL1 Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 N-male to N-male Coaxial Jumper Cables between Combiner/Splitter and Fusion Main Hub’s Downlink Port for either Band 1, Band 2, or Band 3 N-male to N-male Coaxial Jumper Cables between Combiner/Splitter and Fusion Main Hub’s Uplink Port for either Band 1, Band 2, or Band 3 2 x 1 Power Combiner/Splitter 2 x 1 Power Combiner/Splitter Coaxial Jumper Cable N-male to N-male Coaxial Jumper Cable N-male to N-male Circulator Insert attenuator, if needed 7-48 CONFIDENTIAL Base Station to Repeater or Coaxial Jumper Cable N-male to N-male InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Connecting Contact Alarms to a Fusion System 7.7 Connecting Contact Alarms to a Fusion System The Fusion Main Hub can generate (source) two contact alarms as well as sense three external contact alarm. • Alarm Source (refer to Section 7.7.1 on page 7-50) The Fusion Main Hub has two alarm contacts, fault (major) and warning (minor). These contacts are normally-closed (NC) and will open when an internal alarm is detected. NOTE: The contact can be changed to normally-open (NO) with AdminBrowser. This is not recommended since no alarm would be sent if power to the Fusion Main Hub fails. • Fault is activated when any faults or disconnects are detected. • Warning is activated when any warning conditions are detected except lockout or when the end-to-end system test is not valid. • Alarm Sense (refer to Section 7.7.2 on page 7-53) The Fusion Main Hub can monitor 3 external alarm contacts. Each port can be configured for normally-open (NO) or normally-closed (NC) contacts. The interface expects a set of floating contacts, and an external voltage source is not required for this interface. Use AdminBrowser to monitor the port status. Table 7-8 lists the alarm types, equipment to which the Fusion Main Hub is connected, cable(s) used, and the faults and warnings that are detected. Table 7-8 Alarm Types Alarm Type Fusion Connected to Cable(s) Used Errors Detected Source MetroReach 5-port Alarm Daisy-Chain Cable Faults Source BTS 5-port Alarm Daisy-Chain Cable Faults and Warnings In addition, a custom daisy-chain cable-to-BTS interface cable is required. Make this interface cable to the desired length and with the appropriate pin placement. Sense Unison 5-port Alarm Daisy-Chain Cable and the Alarm Sense Adapter Cable Faults Note that Unison and MetroReach Focus support only faults (major errors). Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-49 CONFIDENTIAL Connecting Contact Alarms to a Fusion System Do not mix Unison and Fusion Main Hubs in the same daisy-chain. You can daisy-chain multiple Unison Hubs together and use the Alarm Sense Adapter Cable to connect the chain to a Fusion Main Hub, which will act as an alarm sensor. 7.7.1 Alarm Source Fusion always acts as an alarm source, no matter what type of equipment you are connecting to. Refer to Section 7.7.2 on page 7-53 if you want Fusion to sense Unison contact closures or other external alarms. Using MetroReach Focus to Monitor Fusion When you connect MetroReach Focus to the Fusion, the Fusion Main Hub is the output of the alarms (alarm source) and Focus is the input (alarm sense), as shown in Figure 7-22. Focus supports only faults (major errors). Figure 7-22 Connecting MetroReach to Fusion MetroReach Focus RFM Fusion Main Hub Band 1 UL1 RF OUT DOWNLINK Band 3 Band 2 UL3 UL2 AC Power Alarms DL2 DL1 DL3 May need 9-pin Adapter, which ships with the cable RF IN UPLINK FIBER 5-port Alarm Daisy-Chain Cable Alarm Source UPLINK DOWNLINK Alarm Sense ALARM RS-232C Band 1 UL1 Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 Alarm Source 7-50 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Connecting Contact Alarms to a Fusion System Using a Base Station to Monitor Fusion NOTE: The BTS must be configured, by the carrier, for contact closure monitoring prior to connecting a Fusion Main Hub to it. When you connect a BTS to Fusion, the Fusion Main Hub is the output of the alarms (alarm source) and the BTS is the input (alarm sense), as shown in Figure 7-23. An interface cable is required between the daisy-chain cable and the BTS. Because BTS alarm interface pinouts and Fusion-to-BTS distances vary, this cable is often custom and wired on-site. Refer to Section 3.2.1 for Alarm Contact details (Normally Closed). Figure 7-23 Using a BTS to Monitor Fusion Fusion Main Hub Band 1 Band 3 Band 2 UL1 UL3 UL2 AC Power Alarms DL3 DL2 DL1 5-port Alarm Daisy-Chain Cable Alarm Source BTS Interface Cable (custom made, on-site) Band 1 UL1 Alarm Sense Band 3 Band 2 UL2 UL3 AC Power Alarms DL1 DL2 DL3 Alarm Source NOTE: For normally open contacts, the fault and warning contacts need to be wired in parallel with other Main Hubs. NOTE: LGC Wireless does not recommend using normally open contacts. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-51 CONFIDENTIAL Connecting Contact Alarms to a Fusion System Using a Base Station and AdminBrowser to Monitor Fusion NOTE: The BTS must be configured, by the carrier, for contact closure monitoring prior to connecting a Fusion Main Hub to it. In order to take full advantage of Fusion’s OA&M capabilities you can use LGC Wireless’ AdminBrowser software in addition to a BTS to monitor the system, as shown in Figure 7-24. Refer to Section 7.8.6 for SNMP optional feature capabilities. Figure 7-24 Using a BTS and AdminBrowser to Monitor Fusion Fusion Main Hub Band 1 UL1 Band 3 Band 2 UL3 UL2 Modem AC Power Alarms DL3 DL2 DL1 Alarm Sense 5-port Alarm Daisy-Chain Cable Alarm Source Band 1 Modem UL1 Band 3 Band 2 UL2 BTS Interface Cable UL3 AC Power Alarms DL1 DL2 DL3 Alarm Source Straight-through modem cable connected to Fusion Main Hub’s front panel serial port Line Switch PC running Standard Browser Software PSTN 7-52 CONFIDENTIAL Modem InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Connecting Contact Alarms to a Fusion System 7.7.2 Alarm Sense Use AdminBrowser to enable the Fusion system for “alarm sense” when connecting to the contact closure of Unison Main Hubs or other external alarms (refer to Set Contact Sense Properties in the AdminBrowser User Manual). Using Fusion to Monitor Unison When you connect Unison to Fusion, the Fusion Main Hub is the input of the alarms (alarm sense) and the Unison is the output (alarm source), as shown in Figure 7-25. The input alarm sense needs to be set to normally closed (NC). Figure 7-25 Band 1 UL1 Band 3 Band 2 UL2 Using Fusion to Monitor Unison UL3 AC Power Alarms DL1 DL2 Up to 5 Unison Main Hubs DL3 Fusion Main Hub 5-port Alarm Daisy-Chain Cable Alarm Sense Adapter Cable Alarm Sense Alarm Source Alarm Source Unison supports only faults. You must use the Alarm Sense Adapter Cable (refer to page 7-56) to interface the daisy-chain cable to Fusion. The adapter cable is required because it translates the Unison fault pinout to the sense input pins on the Fusion Main Hub. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-53 CONFIDENTIAL Connecting Contact Alarms to a Fusion System Figure 7-26 Alarm Sense Contacts +5V External Equipment Contacts Diagnostic I 7-54 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Connecting Contact Alarms to a Fusion System 7.7.3 Alarm Cables 5-port Alarm Daisy-Chain Cable Figure 7-27 shows the 5-port Alarm Daisy-Chain Cable (PN 4024-3), which supports fault and warning conditions. Figure 7-27 5-port Alarm Daisy-Chain Cable 1.2 meters (4 feet) DB-9 female to Base Station, MetroReach Focus, or the Alarm Sense Adapter Cable when connecting Unison DB-9 male to Fusion, Unison, MetroReach Focus, Alarm Port Splice J1 Female J2 Male Splice Connector Hood DB-9 male to Fusion, Unison, MetroReach Focus Alarm Port .5 meter (1.5 feet) Splice J3 Male Splice DB-9 male to Fusion, Unison, MetroReach Focus Alarm Port .5 meter (1.5 feet) Splice J4 Male Splice NOTE: Do not daisy-chain Fusion Main Hubs with Unison or MetroReach Focus if you want both faults and warnings from Fusion. Only faults are reported if you combine Fusion with Unison or MetroReach in the same daisy chain. DB-9 male to Fusion, Unison, MetroReach Focus Alarm Port .5 meter (1.5 feet) Splice J5 Male Splice .5 meter (1.5 feet) J6 Male Option 2: Use J2-J5 for alarm ports. J6 is used to connect to an additional Alarm Daisy-Chain Cable. J7 is not used. .25 meter (.75 feet) Option 1: DB-9 to Fusion, Unison, MetroReach Focus Alarm Port. J7 not used J7 Female Option 3: Connect fewer than 5 ports and terminate the daisy chain by connecting J7 to the lowest unused port. Terminator Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-55 CONFIDENTIAL Connecting Contact Alarms to a Fusion System Alarm Sense Adapter Cable The alarm sense adapter cable (PN 4025-1) translates the Unison fault pinout to the sense input pins on the Fusion Main Hub. You must use this adapter cable, illustrated in Figure 7-28, with the 5-port Alarm Daisy-Chain Cable when connecting Unison to Fusion. Figure 7-28 Alarm Sense Adapter Cable To Fusion J9 J8 To Daisy-Chain Cable 3 feet 7-56 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Alarm Monitoring Connectivity Options 7.8 Alarm Monitoring Connectivity Options The following connectivity options are described: • Section 7.8.1 Direct Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-57 • Section 7.8.2 Modem Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-58 • Section 7.8.3 100 BASE-T Port Expander Connection . . . . . . . . . . . . . . . . . 7-67 • Section 7.8.4 POTS Line Sharing Switch Connection . . . . . . . . . . . . . . . . . . 7-68 • Section 7.8.5 Ethernet LAN Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-70 • Section 7.8.6 SNMP Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-71 Note that the only accessory available through LGC Wireless is the Ethernet cross-over 100 BASE-T cable, which is provided with AdminBrowser. 7.8.1 Direct Connection In this configuration, the PC connects directly to the RJ-45 100 BASE-T port on the Fusion Main Hub’s front panel using a cross-over cable. Figure 7-29 OA&M Direct Connection AdminBrower is resident in Fusion. PC running Standard Browser Software Cross-over 100 BASE-T Cable NOTE: The cross-over cable provided with the Fusion Main Hub supports full hardware handshaking, which is required. Refer to Appendix A.4 on page A-8 for cable wiring information. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-57 CONFIDENTIAL Alarm Monitoring Connectivity Options 7.8.2 Modem Connection In this configuration, the PC and the Fusion Main Hub connect to modems and communicate using a standard dial-up telephone connection. Figure 7-30 OA&M Modem Connection Straight-through modem cable Modem PSTN Modem Straight-through modem cable PC running Standard Browser Software NOTE: Refer to Appendix A.3 on page A-7 for the modem cable wiring information. Modem switch settings are as follows for US Robotics modem: • PC-side: 3, 4 and 8 Down (“ON” position) • Fusion Hub-side: 1, 4 , 5 and 8 Down (“ON” position) 7.8.2.1 Setting Up Fusion Modem Using AdminBrowser Use the following steps to set up a PPP Dial-In on Fusion: 7-58 CONFIDENTIAL 1. Start AdminBrowser as explained in the AdminBrowser manual. 2. Select System Configuration. 3. Select Setup Modem Connection. The window shown in Figure 7-31 appears. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Alarm Monitoring Connectivity Options Figure 7-31 7.8.2.2 Default Dial-in Settings (Fusion Hub) 4. Make the desired changes. 5. Click Setup Connection. Setting Up a PC Modem Using Windows Use the following sets to set up a dial-up connection on your PC: 1. Click Start, Settings, Network Connections. The window shown in Figure 7-32 appears. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-59 CONFIDENTIAL Alarm Monitoring Connectivity Options Figure 7-32 2. Click Create a new connection. The window shown in Figure 7-33 appears. Figure 7-33 3. 7-60 CONFIDENTIAL Network Connections Window New Connection Wizard - Welcome Window Click Next. The window shown in Figure 7-34 appears. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Alarm Monitoring Connectivity Options Figure 7-34 4. Select Connect to the network at my workplace and click Next. The window shown in Figure 7-35 appears. Figure 7-35 5. New Connection Wizard - Network Connection Type Window New Connection Wizard - Network Connection Window Select Dial-up connection and click Next. The window shown in Figure 7-36 appears. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-61 CONFIDENTIAL Alarm Monitoring Connectivity Options Figure 7-36 6. Type a name for this connection and click Next. The window shown in Figure 7-37 appears. Figure 7-37 7. 7-62 CONFIDENTIAL New Connection Wizard - Connection Name Window New Connection Wizard - Phone Number to Dial Window Type the desired dial in phone number and click Next. The window shown in Figure 7-38 appears. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Alarm Monitoring Connectivity Options Figure 7-38 8. Select Anyone’s use and click Next. The window shown in Figure 7-39 appears. Figure 7-39 9. New Connection Wizard - Connection Availability Window New Connection Wizard - Completing New Connection Window Click Finish. The window shown in Figure 7-40 appears. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-63 CONFIDENTIAL Alarm Monitoring Connectivity Options Figure 7-40 10. Connect Fusion Hub Window Type a password as indicated and click Properties. The window shown in Figure 7-41 appears. The default parameters are as follows: • User name: pppuser • Password (one word, all lower case): password Figure 7-41 11. 7-64 CONFIDENTIAL Fusion Hub Properties Window Click Configure... The window shown in Figure 7-42 appears. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Alarm Monitoring Connectivity Options Figure 7-42 Modem Configuration Window 12. Select the modem speed and other parameters for your modem as desired and click OK. 13. Select the Security tab. The window shown in Figure 7-43 appears. Figure 7-43 14. Fusion Hub Properties - Security Tab Window Select Typical and then click the Networking tab. The window shown in Figure 7-44 appears. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-65 CONFIDENTIAL Alarm Monitoring Connectivity Options Figure 7-44 15. Select Internet Protocol (TCP/IP) as shown and click Properties. The window shown in Figure 7-45 appears. Figure 7-45 7-66 CONFIDENTIAL Fusion Hub Properties - Networking Tab Window Internet Protocol Properties Window 16. Select Obtain an IP address automatically and Obtain DNS server address automatically and click OK. 17. To connect to the Fusion Hub over the Dial-up connection, start you web browser and type the server IP address configured in Section 7.8.2.1 in the address bar. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Alarm Monitoring Connectivity Options 7.8.3 100 BASE-T Port Expander Connection In this configuration a LAN switch is used to allow the connection of multiple devices to a single PC with a 100 BASE-T port. Testing was performed with a Linksys 4-port switch. A standard RJ-45 Ethernet cable must be made to connect the LAN switch to the Fusion Main Hub. Figure 7-46 OA&M Connection using a 232 Port Expander AdminBrowser software is resident in Fusion. 100 BASE-T Cable RJ-45 male to RJ-45 male PC running Standard Browser Software LAN switch 100 BASE-T Ethernet connection Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-67 CONFIDENTIAL Alarm Monitoring Connectivity Options 7.8.4 POTS Line Sharing Switch Connection Using a line sharing switch, you can connect up to four modems to a single telephone line. Testing was performed with a Teltone Line Sharing Switch, model number M-394-B-01. Figure 7-47 PC running Standard Browser Software Straight-through modem cable OA&M Connection Using a POTS Line Sharing Switch Modem PSTN Line Sharing Switch Modem Standard phone cable Up to 4 modems per Switch Modem Straight-through modem cable Up to 16 modems can be monitored using a single telephone line by cascading line sharing switches, as shown in Figure 7-48. 7-68 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Alarm Monitoring Connectivity Options Figure 7-48 Straight-through modem cable PC running Standard Browser Software Cascading Line Sharing Switches PSTN Modem Line Sharing Switch Standard phone cable Line Sharing Switch Line Sharing Switch Straightthrough modem cables Line Sharing Switch Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A Line Sharing Switch 7-69 CONFIDENTIAL Alarm Monitoring Connectivity Options 7.8.5 Ethernet LAN Connection An Ethernet LAN connection can be used to communicate between the PC and Fusion. Testing was performed with an Linksys 4-port LAN switch. Figure 7-49 OA&M Connection Using Ethernet and ENET/232 Serial Hub 100 BASE-T Cable RJ-45 to RJ-45 male LAN Switch Ethernet TCP/IP PC running Standard Browser Software Ethernet 7-70 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Alarm Monitoring Connectivity Options 7.8.6 SNMP Interface Faults and warnings can also be diagnosed with SNMP using a standard (NMS) network management system (optional). SNMP resident software in Fusion provides SNMP interactions for Traps and Notification. The Fusion SNMP includes a MIB for integrating into the Network Management System (NMS) and supports SNMPv1 and SNMPv2c. Figure 7-50 Fusion SNMP Configuration Options Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 7-71 CONFIDENTIAL Alarm Monitoring Connectivity Options 7-72 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Replacing Fusion Components SECTION 8 This section contains the following subsections: • Section 8.1 Replacing an RAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 • Section 8.2 Replacing a Fusion Expansion Hub . . . . . . . . . . . . . . . . . . . . . . . 8-3 • Section 8.3 Replacing a Fusion Main Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4 8.1 Replacing an RAU Be aware that the new RAU must support the same bands as the one you are replacing. If the RAU is of the wrong band combination, it will not operate properly in the system. Replacing an RAU 1. Using AdminBrowser, log in and click SYSTEM INFORMATION. 2. Click SHOW SYSTEM TREE, select Fusion Main Hub, and click GET SYSTEM INFORMATION. All system settings for Hubs and RAUs will be displayed. Write down or save the Uplink and Downlink Attenuation setting so you can set the new RAU with the same settings. 3. Click CANCEL to close the window. 4. Verify that the new RAU is of the same frequency bands as the one replaced. 5. Disconnect the CATV cable and antenna cable from the unit to be replaced. 6. Install the new RAU. 7. Connect the antenna cable and then the CATV cable to the new RAU. 8. Click SYSTEM CONFIGURATION. 9. Click SHOW SYSTEM TREE. 10. Select the Fusion RAU replaced and click EDIT UNIT PROPERTIES. InterReach Fusion Installation, Operation, and Reference Manual D-x620610-0-20 Rev A 8-1 CONFIDENTIAL Replacing an RAU 11. Set the attenuation of each band as the old RAU was programmed and click SAVE PROPERTIES. Perform System Test When convenient, perform System Test to optimize performance. During System Test, the entire system is temporarily off-line and no RF is being transmitted. Checking the RAU’s LEDs 1. The RAU’s LINK and ALARM LEDs should blink (green/red) on power up. • If the LEDs do not blink on power up, replace the RAU. 2. After several seconds both LEDs should change to green, which indicates that the unit has been successfully replaced, there is communication with the Hub, and the RAU band is correct. a. If the LINK LED remains green and the ALARM LED remains red, verify that the RAU model is correct for the intended frequency band. – Disconnect the cable and then reconnect it once; doing this more than once will not change the result. 8-2 CONFIDENTIAL b. If both LEDs still don’t change to green, use AdminBrowser to determine the exact nature of the fault and see a recommendation of how to correct it. c. If both LEDs turn red (after 90 seconds), the Hub has terminated communications. InterReach Fusion Installation, Operation, and Reference Manual D-x620610-0-20 Rev A Replacing a Fusion Expansion Hub 8.2 Replacing a Fusion Expansion Hub Replacing a Fusion Expansion Hub 1. Turn off the power to the Expansion Hub. 2. Disconnect all CATV cables, both fiber cables, and the AC power cord. 3. Replace the Expansion Hub with a new one. 4. Connect the AC power cord, all CATV cables, and both fiber cables – remembering to clean and correctly connect the uplink and downlink fiber. 5. Turn on the power to the Expansion Hub. AdminBrowser Tasks • The Main Hub automatically issues the band setting. • When convenient, use AdminBrowser to perform System Test in order to optimize performance. During System Test, the entire system is temporarily off-line and no RF is being transmitted. For a fully loaded system (one Main Hub, four Expansion Hubs, and 32 RAUs), it can take up to 1.5 minutes to complete the test. Checking the Expansion Hub’s LEDs • The LEDs should blink through all states on power up. • If the LEDs do not blink on power up, replace the Expansion Hub. • If the LEDs do not illuminate at all, make sure the AC power cable is connected. • The UL STATUS and DL STATUS LEDs should be green. • The E-HUB STATUS and POWER LEDs should be green. • For each CATV port that has an RAU connected the LEDs should be green. It can take several seconds for each CATV connection for the LEDs to display properly. NOTE: Refer to Section 9 for troubleshooting using the LEDs. Help Hot Line (U.S. only): 1-800-530-9960 D-x620610-0-20 Rev A 8-3 CONFIDENTIAL Replacing a Fusion Main Hub 8.3 Replacing a Fusion Main Hub You must record the system configuration settings from the old Fusion Main Hub’s memory before replacing the unit. You will program the new Main Hub with this information. If the Main Hub is programmed incorrectly, the system will not work. If the Hub to be replaced is not functioning and you cannot use AdminBrowser, get the configuration settings from the As-Built Document that was created as part of the original installation. Replacing a Fusion Main Hub 1. Using AdminBrowser, log in, click SYSTEM INFORMATION, click SHOW SYSTEM TREE, select Fusion Hub, click GET SYSTEM INFORMATION. 2. Turn off the power to the Fusion Main Hub. 3. Disconnect all cables and the AC power cord. 4. Replace the Main Hub with a new one. 5. Connect the AC power cord and all cables. 6. Connect the crossover Ethernet cable to the PC and then to the Main Hub’s front panel 100Base-T connector. ADMIN/LAN port) 7. Start the standard browser on the PC to communicate with AdminBrowser software. 8. Turn on the power to the Main Hub. 9. Observe the LEDs after turning on the power. All the LEDs blink during the initial power up sequence. All LEDs should turn green after the power on sequence is complete. Power up sequence takes between 1 and 2 minutes depending on the number of RAUs. Configure the New Fusion Main Hub 8-4 CONFIDENTIAL 1. Using AdminBrowser and log in to the Main Hub. 2. Click SYSTEM CONFIGURATION. 3. Click SET DATE/TIME and enter the current date and time. 4. Click SET DATE/TIME. 5. Follow the instructions to eventually reboot the system to set the date and time. 6. Using AdminBrowser, log in and click SYSTEM CONFIGURATION. 7. Click INSTALL SYSTEM. 8. Set the new Main Hub parameters from the old Main Hub and click INSTALL SYSTEM (that is, uplink and downlink gain, system labels, and so on). 9. Follow the instructions to perform a System Test. InterReach Fusion Installation, Operation, and Reference Manual D-x620610-0-20 Rev A Replacing a Fusion Main Hub 10. Click SYSTEM CONFIGURATION and click on SETUP NETWORK CONNECTION OR MODEM CONNECTION if the Main Hub has Network or Modem equipment connected to it. During System Test, the entire system is temporarily off-line and no RF is being transmitted. Checking the Main Hub’s LEDs • The LEDs should blink through a 5-second test on power up. • If the LEDs do not blink on power up, replace the Main Hub. • If the LEDs do not illuminate at all, make sure the AC power cable is connected. • For each fiber optic port that has a connected Expansion Hub, which has been programmed with a band, the PORT LED should be green. • Refer to Section 9.3, “Troubleshooting,” on page 9-3 for more LED states. NOTE: If there is no communication between the Main Hub and the Expansion Hubs, use the AdminBrowser to isolate system problems. Help Hot Line (U.S. only): 1-800-530-9960 D-x620610-0-20 Rev A 8-5 CONFIDENTIAL Replacing a Fusion Main Hub 8-6 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-x620610-0-20 Rev A Maintenance, Troubleshooting, and Technical Assistance SECTION 9 This section contains the following subsections: • Section 9.1 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 • Section 9.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 • Section 9.3 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3 • Section 9.4 Troubleshooting CATV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 • Section 9.5 Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 9.1 Service There are no user-serviceable parts in any of the Fusion components. Faulty or failed components are fully replaceable through LGC Wireless. All units should be replaced and returned to the factory for service if needed. Address 2540 Junction Avenue San Jose, California 95134-1902 USA Phone 1-408-952-2400 Fax 1-408-952-2410 Help Hot Line 1-800-530-9960 (U.S. only) +1-408-952-2400 (International) Web Address http://www.lgcwireless.com e-mail lgccustomersupport@lgcwireless.com InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A 9-1 CONFIDENTIAL Maintenance 9.2 Maintenance Keep the fiber ports clean and free of dust. No other periodic maintenance of the Fusion equipment is required. To clean the fiber ports: You can clean the Hub’s fiber ports using canned compressed air or isopropyl alcohol and cotton swabs. Considerations: • If you use compressed air: • The air must be free of dust, water, and oil. • Hold the can level during use. • If using isopropyl alcohol and foam-tipped swab: • Use only 98% pure or more alcohol. Procedure using compressed air: 1. Remove the connector’s dust cap. 2. Spray the compressed air away from the unit for a few seconds to clean out the nozzle and then blow dust particles out of each fiber port. Procedure using isopropyl alcohol: 1. Remove the connector’s dust cap. 2. Dip a 2.5mm lint-free, foam-tipped swab in isopropyl alcohol and slowly insert the tip into the connector. 3. Gently twist the swab to clean the connector. 4. Insert a dry swab to dry the connector. Additionally, you can use compressed air after the alcohol has completely evaporated. 9-2 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Troubleshooting 9.3 Troubleshooting NOTE: Fusion has no user-serviceable parts. Faulty or failed units are fully replaceable through LGC Wireless. Sources of potential problems include: • Faulty cabling/connector • Malfunction of one or more Fusion components • Antenna, base station, or repeater problem • External RF interface • Tripped circuit breaker • Equipment is not grounded • Using an Ethernet crossover cable that does not support full hardware handshaking when using AdminBrowser NOTE: Faulty cabling is the cause of a vast majority of problems. All CATV 75 Ohm cable should be tested to TIA-570-B specifications. The RAU will be damaged if the cable connector is not installed properly. You must use AdminBrowser for troubleshooting the system, use the LEDs only as backup or for confirmation. If you cannot determine the cause of a problem after following the recommended procedures, call LGC Wireless customer help hot line: 1-800-530-9960 (U.S. only) +1-408-952-2400 (International) Or, email us at lgccustomersupport@lgcwireless.com. Please provide the following information: • Serial number of the unit • Description of the problem • Using AdminBrowser 1.00, access Special Features, then the Get Service Information window. Save and email this file to LGC Wireless. • What is the length of the CATV cable? What type is it (for example RG-6)? • Status of the LEDs on the unit • Was the unit power cycled? Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 9-3 CONFIDENTIAL Troubleshooting 9.3.1 Troubleshooting Using AdminBrowser Use AdminBrowser software to determine the current faults and warnings for all of the units in the system. To troubleshoot, start with the Fusion Main Hub’s faults AND warnings, then proceed to each of the Expansion Hubs, finishing with each of the RAUs. NOTE: AdminBrowser v1.00 displays events (faults, warnings, or status messages) depending on your view preference. To change your view preference, refer to Section 3.3.2, “View Preference,” on page 3-10. System Troubleshooting Using AdminBrowser, click SYSTEM INFORMATION, then click GET FAULTS, WARNINGS AND STATUSES. This gives the present status of the system, depending upon View Preferences for all components. Faults usually impact service; warnings may impact service; status messages contain information that should not be ignored, but indicate conditions that do not generally impact service. NOTE: System commands can take longer to execute compared to component commands. NOTE: This RAU icon indicates there is fault on the RAU. This icon indicates a disconnected device. You cannot request status on a disconnected device. 9.3.1.1 Troubleshooting Recommendations Some actions that you can take, depending on the device fault or warning include, are as follows: a. Hardware faults on Expansion Hub. – Try swapping fiber with another Expansion Hub at the Main Hub. – Try cleaning the fiber and the fiber ports with alcohol foam tip swab and compressed air. See Section , “To clean the fiber ports:,” on page -2. – Power cycle the Expansion Hub. b. 9-4 CONFIDENTIAL Under Alarms, click CLEAR ALL DISCONNECTS at the Fusion Main Hub. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Troubleshooting c. Power cycle the Fusion Main Hub. d. RAU hardware faults. Try moving a working CATV to the suspect port and verifying that the RAU comes up OK. e. Try isolating the system components: – Check to see if the whole system is effected or a portion of the system. – If the whole system is effected, disconnect the DAS system from the RF source and see if the RF source is working. – Continue to isolate by disabling portions of the system. Under System Configuration, click SHOW SYSTEM TREE and select a component. Then click SET OUT OF SERVICE/SET IN SERVICE. 9.3.1.2 Fault/Warning/Status Indications Once all of the units are powered on and the cable connections are made, the faults from each unit can be requested using AdminBrowser. Start with the Fusion Main Hub and work downstream. Resolve all faults first and then check the warnings. Take appropriate action to resolve the faults, as indicated in the following tables. In cases where there is more than one possible cause, they are listed from the “most likely” to the “least likely” cause. Actions are listed in the order that they should be performed; not all actions may need to be done. NOTE: If you have a red STATUS LED without a fault message, it probably indicates that the unit is locked out. Refer to Appendix C for tables containing Fault, Warning, and Status messages and their meanings. 9.3.2 Troubleshooting Using LEDs The following troubleshooting guide is from the perspective that all Fusion equipment is installed, their cables are connected, and they are powered on; it is assumed that the system was operating normally before the problem to be diagnosed occurred. Always use AdminBrowser, if possible, to troubleshoot the system. The Fusion Main Hub and Expansion Hub LEDs are for backup troubleshooting. The RAU LEDs probably will not provide additional information for troubleshooting. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 9-5 CONFIDENTIAL Troubleshooting 9.3.2.1 Troubleshooting Main Hub LEDs During Normal Operation All of the Main Hub’s LEDs should be green during normal operation. If any LEDs are red, get status using AdminBrowser to determine the exact cause and recommendations. Table 9-1 During Normal Operation Expansion Hub Not Connected Troubleshooting Main Hub Port LEDs During Normal Operation Main Hub Port LEDs State Action Impact PORT Red If the Expansion Hub was disconnected accidentally, re-connect the cables. The LEDs should change to Green/Red (then Green/Green, after 20 seconds, if the Main Hub band has been programmed). The Expansion Hub was previously connected, but it is not currently connected; the Expansion Hub uplink cable disconnected. When the Expansion Hub is to be removed from service permanently, use AdminBrowser’s ‘Clear All Disconnect Status’ command to clear all disconnect states to no connect states. Expansion Hub Connected PORT Red 60 ppm) Use AdminBrowser to determine the exact cause of the Main Hub’s faults. AdminBrowser clears all disconnects caused by installation as part of the clean-up process. After installation, power cycle the Main Hub or use AdminBrowser’s “Clear All Disconnect Status” command. Changes the Main Hub’s port LEDs to Off/Off. Lost communication with Expansion Hub; could be Expansion Hub problem or fiber cable problem. The Expansion Hub communication problems delay MH responses to AdminBrowser commands, resulting in command time-outs. You can disconnect the offending Expansion Hub initially to obtain status from the rest of the system, then connect the Expansion Hub and resolve the communication problem. PORT 9-6 CONFIDENTIAL Red The Expansion Hub or connected RAU reports a fault condition; use AdminBrowser to determine the exact cause of the Expansion Hub and RAU’s faults. Degraded performance or unit may be off-line. Depends on fault condition. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Troubleshooting Table 9-2 During Normal Operation Main Hub Status LEDs At Any Time MAIN HUB STATUS Troubleshooting Main Hub Status LEDs During Normal Operation State Action Impact Red Use AdminBrowser to determine the exact cause of the fault. Internal Main Hub fault. Power cycle one time. If the fault remains, replace the Main Hub. Use AdminBrowser to check if the Main Hub is commanded Out-of-Service (every Expansion Hub port status LED will be red as well). The Main Hub and all downstream units are off-line. A power cycle will not clear a commanded Out-of-Service, you must use AdminBrowser to clear this state. At Any Time MAIN HUB STATUS Flashing Red (60ppm( Reduce input signal power. Signal compression. POWER Red Replace the Main Hub. One or more power supplies are out of specification. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A 9-7 CONFIDENTIAL Troubleshooting 9.3.2.2 Troubleshooting Expansion Hub LEDs During Normal Operation • All of the Expansion Hub LINK and E-HUB/RAU LEDs that have RAUs connected should be Green/Green, indicating that the RAU is powered on, communication is established, and operation is normal. • The POWER, EHUB STATUS, DL STATUS, and UL STATUS LEDs should all be Green. Troubleshooting Expansion Hub Port LEDs During Normal Operation Table 9-3 During Normal Operation Expansion Hub Port LEDs State Action Impact RAU is not connected PORT Off If the RAU was disconnected accidentally, re-connect the CATV cable. The Expansion Hub’s port LEDs should change to Green/Red (then Green/Green, after 20 seconds, if the Main Hub is connected, powered on, and has band programmed). The RAU was previously connected, but it is not currently connected; the RAU cable is disconnected. Use AdminBrowser’s “Clear All Disconnect Status” command if you are permanently removing the RAU from service. The Expansion Hub’s port LEDs should change to Off/Off. RAU is connected 9-8 CONFIDENTIAL PORT Red Disconnect/reconnect the CATV cable to force power-on reset to the RAU. If the port LEDs remain Red check for the exact cause of Expansion Hub faults using AdminBrowser. Lost communications with the RAU. The RAU could have powered down due to over current; cable could have been damaged. PORT Flashing Red (60 ppm) The RAU reports a fault condition; check for the exact cause of Expansion Hub and RAU faults using AdminBrowser. Depends on the fault condition. PORT Flashing Red (60 ppm) The Expansion Hub reports no connection, cable shorts, or a current port trap condition. Expansion Hub communications with the RAU. The Expansion Hub is at fault. The cable could have been damaged. The cable leads may be shorted. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Troubleshooting Table 9-4 Troubleshooting Expansion Hub Status LEDs During Normal Operation During Normal Operation Expansion Hub Status LEDs State Action Impact At Any Time UL STATUS Red Check uplink fiber for optical loss. No communications between the Main Hub and the Expansion Hub. Power cycle Expansion Hub one time to check uplink laser. Red Check the downlink fiber for optical loss No communications with the Main Hub. E-H STATUS Red If either the UL STATUS or the DL STATUS are also red, see above. Internal Expansion Hub fault (including either of the above UL STATUS or DL STATUS states). Cycle power on the Expansion Hub. If fault remains, replace the Expansion Hub. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A Uplink laser failure. DL STATUS 9-9 CONFIDENTIAL Troubleshooting CATV 9.4 Troubleshooting CATV The following table summarizes CATV problems, as reported by AdminBrowser if a cable is cut or miswired. NOTE: Recommended minimum and maximum CATV cable lengths vary depending upon the type of CATV cable used. Refer to Section 6.1.2, “Cable and Connector Requirements,” on page 6-2. Table 9-5 Summary of CATV Cable Wiring Problems Problem Type Message Loose connector, shorted conductor or improper connection to the shield. None High phase noise, degraded signal on both Downlink and Uplink (high bit error rate) • No communication with RAUn RAU unable to communicate with Hub, degraded performance or RAU off-line • Portn UL RF path loss is too high Increased ripple in the uplink path, decreased UL gain, or no UL gain • The DL RF path loss is too high Increased ripple in the downlink path, RAU off-line • RAUn over current or port short RAU will not power on. 9.5 Icon Impact Technical Assistance Call our help hot line for technical assistance: 1-800-530-9960 (U.S. only) +1-408-952-2400 (International) lgccustomersupport@lgcwireless.com Leave your name and phone number and an LGC Wireless customer service representative will return your call within an hour. Be prepared to provide the following information when you receive the return call: • Company name • End user name • Type of system, model number, frequency • Approximate time in service (warranty), sales order number • Description of problem • LED status • AdminBrowser faults, warnings, and status messages 9-10 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Cables and Connectors APPENDIX A A.1 75 Ohm CATV Cable • Connects the Expansion Hub to the RAU(s) • Transmits multiband (downlink) and receives (uplink) IF signals • Delivers DC electrical power to the RAUs. The Fusion Hub’s DC voltage output is 54V DC nominal. A current limiting circuit is used to protect the Hub if it reaches its current limit • Carries configuration and status information • Use 75 Ohm type-F connectors with captive centerpins • Lengths: RG-59: • Minimum: 0 meters (0 ft.) • Maximum: 150 meters (492 ft.) RG-6: • Minimum: 0 meters (0 ft.) • Maximum: 170 meters (558 ft.) RG-11: • Minimum: 0 meters (0 ft.) • Maximum: 275 meters (902 ft.) Recommended minimum and maximum CATV cable lengths vary depending upon which CATV cable you use. Be sure to test cable termination before installing the cable. CommScope CATV cable or equivalent is required: CommScope 20655V for RG-59. This cable is illustrated in Figure A-1. CommScope 2279V for RG-6. This cable is illustrated in Figure A-2. CommScope 2293K for RG-11.This cable is illustrated in Figure A-3. InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A A-1 CONFIDENTIAL Figure A-1 A-2 CONFIDENTIAL CommScope 2065V for RG-59 InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Figure A-2 CommScope 2279V for RG-6 Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A A-3 CONFIDENTIAL Figure A-3 CommScope 2293K for RG-11 NOTE: LGC Wireless requires solid copper center conductor CATV cable for proper DC voltage to the RAU and maximum distances. A-4 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Use the following connectors and tools to prepare the cable ends: CommScope cable part number: 2065V Canare part number: F connector FP-C4F Crimp Tool TC-1, Crimp Die TCD-4C, Cable Strip preparation tool TS100E CommScope cable part number: 2279V Canare part number: F connector FP-C55A Crimp Tool TC-1, Crimp Die TCD-35CA, Cable Strip preparation tool TS100E CommScope cable part number: 2293V Canare part number: F connector FP-C71A Crimp Tool TC-1, Crimp Die TCD-7CA, Cable Strip preparation tool TS100E If the maximum distance is not required, then copper-clad over steel-center conductor cable may be used to reduce cable costs. Table A-2 shows CommScope cable choices of plenum, non-plenum, solid copper conductor, and copper-clad over-steel conductor cable with their part numbers and maximum distances. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A A-5 CONFIDENTIAL System Gain (Loss) Relative to CATV Cable Length (All RAUs except 800/900/1900) Table A-1 Cable Type CommScope Part Number Plenum Rated Solid Copper Conductor 2065V Yes Copper Clad Conductor Zero-loss RF Maximum Length (meters) Distance Where RF is 10dB Below Input RF (meters) 150 210 RG-59 2022V Yes 120 120* 5572R No 110 110* 5565 No 150 210 2279V Yes 170 230 2275V Yes 170 175* 5726 No 170 170* 5765 No 170 230 2293K Yes 275 375 2285K Yes 275 370* 5913 No 275 370* RG-6 RG-11 * Exceeding the distance of copper-clad cable will result in the attached RAU becoming non-functional. If the distance of a cable run is at its maximum and is of concern, LGC recommends the use of solid copper cable to ensure successful operation. A-6 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Table A-2 System Gain (Loss) Relative to CATV Cable Length for 800/900/1900 RAUs Cable Type Zero-loss RF Maximum Length (meters) Distance Where RF is 10dB Below Input RF (meters) 150 210 80 80* 70 70* 150 210 CommScope Part Number Plenum Rated Solid Copper Conductor 2065V Yes 2022V Yes 5572R No 5565 No 2279V Yes 170 230 2275V Yes 115 115* 5726 No 110 110* 5765 No 170 230 2293K Yes 275 375 Copper Clad Conductor RG-59 RG-6 RG-11 2285K Yes 240 240* 5913 No 240 240* * Exceeding the distance of copper-clad cable will result in the attached RAU becoming non-functional. If the distance of a cable run is at its maximum and is of concern, LGC recommends the use of solid copper cable to ensure successful operation. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A A-7 CONFIDENTIAL A.2Fiber Optical Cables • Connects the Main Hub to Expansion Hub(s) • Transmits (downlink) and receives (uplink) optical signals • Carries configuration and status information • Use industry-standard 62.5µm/125µm MMF or Corning SMF-28 fiber, or equivalent. • SC/APC (angle-polished) connectors are required throughout the fiber network (port-to-port), including fiber distribution panels • Distances: • Multi-mode Fiber: up to 500 m (1,640 ft) – 3 dB optical loss maximum • Single-mode Fiber: up to 6 km (19,685 ft) – 3 dB optical loss maximum A.3 Coaxial Cable • Connects a Fusion Hub to a repeater or base station (N-type connectors) • Connects an RAU to a passive antenna (N-type connectors) A-8 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A A.4 Standard Modem Cable This cable (PN 4028-10) connects a modem to the Fusion Hub’s front panel serial port. Figure A-1 Standard Modem Cable Pinout DB-9 Connector Pin DB-25 Connector Pin 20 22 Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A A-9 CONFIDENTIAL A.5 TCP/IP Cross-over Cable A TCP/IP cross-over cable (PN 4069-ADB) is used to connect a standard browser PC A cable is included with the Fusion Hub. The pinouts for this cable are illustrated in Figure A-2. Straight Connect Top View of to the the Wiring Map for Categorywith 5 (CAT UTP Cable AdminBrowser a 5)Fusion Hub. (TIA/EIA 568-A Standard) Figure A-2 1 2 4 5 7 8 1 2 3 4 5 6 7 8 W-G W-O BL W-BL W-BR BR Connector 1 (586A) Wiring Map for TCP/IP Cable RJ-45 Port Green/ Green Orange/ Blue Blue/ Orange Brown/ Brown White White White White Connector 2 (586B) A-10 CONFIDENTIAL 3 6 7 8 W-O W-G BL W-BL W-BR BR 1 2 3 4 5 6 7 8 RJ-45 Port InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A A.6 DB-25 to DB-9 Null Modem Cable Use a DB-9 female to DB-9 female null modem cable to connect the craft person’s PC/Laptop to the RS-232 port on the front of the Fusion Hub for IP address configuration. Table A-3 lists the cable pinout and Figure A-3 shows a diagram of its wiring. Table A-3 DB-9 Female to DB-9 Female Null Modem Cable Pinout From Signal To Signal P1-4 DTR P2-6, P2-1 DSR, DCD P1-6 DSR P1-1, P2-4 DCD, DTR P1-3 TXD P2-2 RXD P1-2 RXD P2-3 TXD P1-5 GND P2-5 GND P1-7 RTS P2-8 CTS P1-8 CTS P2-7 RTS P1-9 N/C N/C N/C Figure A-3 DB-9 Female to DB-9 Female Null Modem Cable Diagram DB-9 Connector Pin DB-9 Connector Pin Note that for each DB-9 connector, pins 1 and 6 are tied together and sent to pin 4 of the opposite connector, providing the required handshake signals. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A A-11 CONFIDENTIAL A-12 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Compliance APPENDIX B B.1 Fusion System Approval Status InterReach Fusion has been approved as shown below. 800 SMR/iDEN Products • Safety: UL 60950, 3rd Edition • EMC: FCC part 15 class A • Radio: FCC Part90 850 Cellular Products • Safety: CB scheme evaluation to IEC 60950, 3rd Edition with all national deviations. • EMC: FCC part 15 class A • Radio: FCC Part 22 900 Paging/SMR/iDEN Products • Safety: UL 60950, 3rd Edition • EMC: FCC part 15 class A • Radio: FCC Part 90 1800 DCS Products-Pending • Safety: CB scheme evaluation to IEC 60950, 3rd Edition with all national deviations. • EMC: EN 301 489-8 V.1.2.1 (2002-08) • Radio: EN 502 V.8.1.2 (2001-07) InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A B-1 CONFIDENTIAL 900 GSM/EGSM Products-Pending • Safety: CB scheme evaluation to IEC 60950, 3rd Edition with all national deviations. • Radio: EN 301 502 V.8.1.2 (2001-07) • EMC: EN 301 489-8 V.1.2.1 (2002-08) 1900 PCS Products • Safety: CB scheme evaluation to IEC 60950, 3rd Edition with all national deviations. • EMC: FCC part 15 class A • Radio: FCC part 24 2100 UMTS Products-Pending • Safety: CB scheme evaluation to IEC 60950, 3rd Edition with all national deviations. • EMC: ETSI TS 125 113 125 113 (2005-12) • Radio: EN 301 908-11 V2.3.1 (2004-10) InterReach Fusion Main Hub and Expansion Hub • Safety: CB scheme evaluation to IEC 60950-1, First Edition with all national deviations. • EMC: FCC part 15 class A • Radio: EN 301 502 V.8.1.2 (2001-07) • EMC: EN 301 489-8 V.1.2. • EMC: ETSI TS 125 113 125 113 (2005-12) • Radio: FCC Part 22H • Radio: FCC part 24 • Radio: EN 301 908-11 V2.3.1 (2004-10) • EMC: CISPR 22A • EMC: CISPR 24 NOTE: for Canadian customers, the Manufacturer’s rated output power1 of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference B-2 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. NOTE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. B.2 Human Exposure to RF The U.S. Federal Communications Commission (FCC) has developed guidelines for evaluation of human exposure to RF emissions. The guidelines incorporate limits for Maximum Permissible Exposure (MPE) for power density of transmitters operating at frequencies between 300 kHz and 100 GHz. Limits have been set for portable, mobile, and fixed equipment. LGC products fall in the category of fixed equipment; products intended to be permanently secured and exposures are evaluated for distances greater than 20cm (7 7/8”). Portable devices fall into exposures of less than 20cm, are SAR evaluations are used. Antenna gain is restricted to 1.5 W ERP (2.49 W EIRP) in order to satisfy RF exposure compliance requirements. If higher than 1.5 W ERP, routine MPE evaluation is needed. The antennas should be installed to provide at least 20 cm from all persons to satisfy MPE requirements of FCC Part 2, 2.1091. Basic MPE evaluation is performed by taking the maximum power output of the equipment, the gain of the antenna to be used, and distance from the antenna, referenced in FCC OET Bulletin 65 “Evaluation Compliance with FCC Guidelines for Human Exposure to Radio Frequency for Electric Fields”. LGC products transmit well below the FCC power density limits. FCC defines power output limits at 20cm distance for various frequency ranges: • Over 300 mHz to 1.5 GHz the limit is determined by frequency/1500 • Above 1.5 GHz the limit is 1mW/cm2 The basic equation for determining power density is: S = PG / 4πR2 1. “Manufacturer’s rated output power” refers to Fusion’s downlink P1dB. The power per carrier tables take into account this power reduction for multiple carriers. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A B-3 CONFIDENTIAL Where S is power density in mW/cm2 PG, the transmitted power from the antenna identified as EIRP (Equivalent Isotropically Radiated Power), is the product of power output of device and antenna gain, in mW. R is the distance of interest from the antenna. Typical Installation Example: Assuming an antenna is placed on a 10 foot ceiling, for a person 6 feet tall, the distance from antenna to body is 4 feet (112 cm.). For a PCS 1900 or Cell 850 remote unit, the maximum power output, according to the power table in Section 6.3 Maximum Output Power per Carrier on page 6-4, is 16.5 dB. Assuming a 7 dBi antenna is used, PG in the equation is equal to 23.5 dB (224 mW) EIRP. Using S = PG/4πR2 S = 224/(4x3.14) x (122)2 = 0.001 mW/cm2 Also, assuming a minimum distance of 20 cm according to FCC regulations” S = 224/(4 x 3.14) x (20)2 = 0.04 mW/cm2 B-4 CONFIDENTIAL InterReach Fusion Installation, Operation, and Reference Manual D-620610-0-20 Rev A Faults, Warnings, Status Tables APPENDIX C This appendix contains the following sections: • Section C.1 Faults Reported by Fusion Main/SingleStar Hubs . . . . . . . . . . . A-1 • Section C.2 Faults Reported for System CPU . . . . . . . . . . . . . . . . . . . . . . . . A-5 • Section C.3 Faults for Fusion Expansion Hubs . . . . . . . . . . . . . . . . . . . . . . . A-6 • Section C.4 Faults for RAUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9 • Section C.5 Warning/Status Messages for Fusion Main/SingleStar Hubs . . A-10 • Section C.6 Warning/Status Messages for System CPUs . . . . . . . . . . . . . . A-15 • Section C.7 Warning/Status Messages for Fusion Expansion Hubs . . . . . . A-16 • Section C.8 Warning /Status Messages for RAUs . . . . . . . . . . . . . . . . . . . . A-19 The following tables contain messages for all versions of firmware, but all messages are not displayed by a given firmware version. C.1 Faults Reported by Fusion Main/SingleStar Hubs Faults indicate service-impacting conditions and should be given immediate attention. Once all of the units are powered on and the cable connections are made, the faults from each unit can be requested using AdminBrowser. Start with the Fusion Main Hub and work downstream. Resolve all faults first and then check the warnings. Take appropriate action to resolve the faults, as indicated in the following tables. In cases where there is more than one possible cause, they are listed from the “most likely” to the “least likely” cause. Actions are listed in the order that they should be performed; not all actions may need to be done. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A C-1 CONFIDENTIAL NOTE: If you have a red STATUS LED without a fault message, it probably indicates that the unit is locked out. Table C-1 C-2 CONFIDENTIAL Fault Messages for Fusion Main/SingleStar Hubs Message Number Description Reason/Action {MF01} Software error occurred and recovered. If this happens repeatedly, replace the Hub. {MF02} Software error occurred and recovered. If this happens repeatedly, replace the Hub. {MF03} Software error occurred and recovered. If this happens repeatedly, replace the Hub. {MF04} Software reset occurred and recovered, or firmware download. If this happens repeatedly, replace the Hub. {MF05} Software error occurred and recovered. If this happens repeatedly, replace the Hub. {MF06} Problem detected in the Hub. Internal communication reset. Contact LGC Wireless Support for more information. {MF07} Hub power cycle. Hub power cycle. {MF08} Internal communications failure. No internal communications in preceding 15 minutes. {MF09} Hardware Reset. Commanded hardware power on reset {MF10} Band not programmed. Use AdminBrowser to program the band. {MF11} Hardware failure (DL Pilot PLL). Cycle power once. If fault persists, replace the Hub {MF12} Hardware failure (DL Pilot Too High). Cycle power once. If fault persists, replace the Hub. {MF13} Hardware failure (DL Pilot Too Low). Cycle power once. If fault persists, replace the Hub. {MF14} Hardware failure (54 VDC). 54 VDC power supply is out of range, replace the Hub {MF15} Hardware failure (RF VDC Power). Loss of DC power to RF circuits, replace the Hub. {MF16} Self Lockout (All Bands). Hub has shutdown the system due to an internal fault. System is offline. {MF17} Hardware failure (DL PLL Band 1). Cycle power once. If fault persists, replace the Hub. {MF18} Hardware failure (UL PLL Band 1). Cycle power once. If fault persists, replace the Hub {MF19} Commanded Out-of-service (Band 1). Band 1 commanded out-of-service by User. {MF20} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF21} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF22} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF23} Problem detected in the Hub Contact LGC Wireless Support for more information. {MF24} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF25} Hardware failure (DL PLL Band 2). Cycle power once. If fault persists, replace the Hub. {MF26} Hardware failure (UL PLL Band 2). Cycle power once. If fault persists, replace the Hub. {MF27} Commanded Out-of-service (Band 2). Band 2 commanded out-of-service by User. {MF28} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF29} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF30} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF31} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF32} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF33} Hardware failure (DL PLL Band 3). Cycle power once. If fault persists, replace the Hub. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A Table C-1 Fault Messages for Fusion Main/SingleStar Hubs (continued) Message Number Description Reason/Action {MF34} Hardware failure (UL PLL Band 3). Cycle power once. If fault persists, replace the Hub. {MF35} Commanded Out-of-service (Band 3). Band 3 commanded out-of-service by User. {MF36} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF37} Problem detected in the Hub Contact LGC Wireless Support for more information. {MF38} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF39} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF40} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF41} Hardware failure (Optical Power Out). Cycle power once. If the fault persists, replace the Hub. {MF42} Problem detected in the Hub Contact LGC Wireless Support for more information. {MF43} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF44} Problem detected in the Hub. Contact LGC Wireless Support for more information {MF45} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF46} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF47} Problem detected in the Hub Contact LGC Wireless Support for more information. {MF48} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MD129} Port 1 Disconnected. Unit is disconnected. {MD130} Port 2 Disconnected. Unit is disconnected. {MD131} Port 3 Disconnected. Unit is disconnected. {MD132} Port 4 Disconnected. Unit is disconnected. {MD133} Port 5 Disconnected. Unit is disconnected. {MD134} Port 6 Disconnected. Unit is disconnected. {MD135} Port 7 Disconnected. Unit is disconnected. {MD136} Port 8 Disconnected. Unit is disconnected. {MC137} Port 1 No Communications. No communications with remote unit. {MC138} Port 2 No Communications. No communications with remote unit. {MC139} Port 3 No Communications. No communications with remote unit. {MC140} Port 4 No Communications. No communications with remote unit. {MC141} Port 5 No Communications. No communications with remote unit. {MC142} Port 6 No Communications. No communications with remote unit. {MC143} Port 7 No Communications. No communications with remote unit. {MC144} Port 8 No Communications. No communications with remote unit. {MT145} Port 1 Cable Fault. Possible electrical short in the coax cable, or RAU problem. {MT146} Port 2 Cable Fault. Possible electrical short in the coax cable, or RAU problem. {MT147} Port 3 Cable Fault. Possible electrical short in the coax cable, or RAU problem. {MT148} Port 4 Cable Fault. Possible electrical short in the coax cable, or RAU problem. {MT149} Port 5 Cable Fault. Possible electrical short in the coax cable, or RAU problem. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-3 CONFIDENTIAL Table C-1 C-4 CONFIDENTIAL Fault Messages for Fusion Main/SingleStar Hubs (continued) Message Number Description Reason/Action {MT150} Port 6 Cable Fault. Possible electrical short in the coax cable, or RAU problem. {MT151} Port 7 Cable Fault. Possible electrical short in the coax cable, or RAU problem. {MT152} Port 8 Cable Fault. Possible electrical short in the coax cable, or RAU problem. {MT153} Port 1 Trip. Remote Unit is drawing too much current. {MT154} Port 2 Trip. Remote Unit is drawing too much current. {MT155} Port 3 Trip. Remote Unit is drawing too much current. {MT156} Port 4 Trip. Remote Unit is drawing too much current. {MT157} Port 5 Trip. Remote Unit is drawing too much current. {MT158} Port 6 Trip. Remote Unit is drawing too much current. {MT159} Port 7 Trip. Remote Unit is drawing too much current. {MT160} Port 8 Trip. Remote Unit is drawing too much current. {MF161} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF162} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF163} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF164} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF165} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF166} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF167} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF168} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF169} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF170} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF171} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF172} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF173} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF174} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF175} Problem detected in the Hub. Contact LGC Wireless Support for more information. {MF176} Problem detected in the Hub. Contact LGC Wireless Support for more information. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A C.2 Faults Reported for System CPU Table C-2 Faults for System CPU Message Number Description Reason/Action {SF01} No internal communications. No internal communications in preceding 2 minutes. Power cycle to clear. {SF02} Problem detected in the system CPU. System CPU performed self reboot to clear. {SF03} Problem detected in the system CPU. System CPU performed self reboot to clear. {SF04} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF05} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF06} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF07} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF08} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF09} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF10} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF11} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF12} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF13} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF14} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF15} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF16} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF17} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF18} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF19} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF20} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF21} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF22} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF23} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF24} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF25} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF26} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF27} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF28} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF29} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF30} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF31} Problem detected in the system CPU. Contact LGC Wireless Support for more information. {SF32} Problem detected in the system CPU. Contact LGC Wireless Support for more information. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-5 CONFIDENTIAL C.3 Faults for Fusion Expansion Hubs Table C-3 Fault Messages for Fusion Expansion Hubs Message Number C-6 CONFIDENTIAL Description Reason/Action {EF01} Software error occurred and recovered. If this happens repeatedly, replace the Hub. {EF02} Software reset occurred and recovered, or firmware download. If this happens repeatedly, replace the Hub. {EF03} Software reset occurred and recovered. If this happens repeatedly, replace the Hub. {EF04} Software reset occurred and recovered. If this happens repeatedly, replace the Hub. {EF05} Software error occurred and recovered. If this happens repeatedly, replace the Hub. {EF06} Firmware download. Firmware download. {EF07} Hub power cycle. Hub power cycle. {EF08} MH communications failure. No communications from MH in THE preceding 90 seconds. {EF09} MH communications failure. EH uplink messages not getting to the MH. {EF10} Hardware failure (PLL). Cycle power once. If the fault persists, replace the Hub. {EF11} Hardware failure (54 VDC). 54 VDC power supply is out of range, replace the Hub. {EF12} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF13} Band not programmed. Cycle power once. If the fault persists, replace the Hub. {EF14} Low optical input power. Check downlink fiber connections. {EF15} Hardware failure (Optical Output Power). Cycle power once. If the fault persists, replace the Hub. {EF16} Self Lockout (All Bands). The Hub has shutdown the system due to an internal fault. The system is offline. {EF17} Commanded Out-of-service (Band 1). Band 1 commanded out-of-service by the user. {EF18} Fault lockout (Band 1). Band 1 out-of-service due to an MH fault. {EF19} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF20} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF21} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF22} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF23} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF24} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF25} Commanded Out-of-service (Band 2). Band 2 commanded out-of-service by the user. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A Table C-3 Fault Messages for Fusion Expansion Hubs (continued) Message Number Description {EF26} Fault lockout (Band 2). Band 2 out-of-service due to MH fault. {EF27} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF28} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF29} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF30} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF31} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF32} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF33} Commanded Out-of-service (Band 3). Band 3 commanded out-of-service by the user. {EF34} Fault lockout (Band 3). Band 3 out-of-service due to an MH fault. {EF35} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF36} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF37} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF38} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF39} Problem detected in the EH. Contact LGC Wireless Support for more information. {EF40} Problem detected in the EH. Contact LGC Wireless Support for more information. {ED129} Port 1 Disconnected. Unit is disconnected. {ED130} Port 2 Disconnected. Unit is disconnected. {ED131} Port 3 Disconnected. Unit is disconnected. {ED132} Port 4 Disconnected. Unit is disconnected. {ED133} Port 5 Disconnected. Unit is disconnected. {ED134} Port 6 Disconnected. Unit is disconnected. {ED135} Port 7 Disconnected. Unit is disconnected. {ED136} Port 8 Disconnected. Unit is disconnected. {EC137} Port 1 No Communications. No communications with remote unit. {EC138} Port 2 No Communications. No communications with remote unit. {EC139} Port 3 No Communications. No communications with remote unit. {EC140} Port 4 No Communications. No communications with remote unit. {EC141} Port 5 No Communications. No communications with remote unit. {EC142} Port 6 No Communications. No communications with remote unit. Reason/Action Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-7 CONFIDENTIAL Table C-3 Fault Messages for Fusion Expansion Hubs (continued) Message Number C-8 CONFIDENTIAL Description Reason/Action {EC143} Port 7 No Communications. No communications with remote unit. {EC144} Port 8 No Communications. No communications with remote unit. {ET145} Port 1 Cable Fault. Possible electrical short in the coaxial cable, or an RAU problem. {ET146} Port 2 Cable Fault. Possible electrical short in the coaxial cable, or an RAU problem. {ET147} Port 3 Cable Fault. Possible electrical short in the coaxial cable, or an RAU problem. {ET148} Port 4 Cable Fault. Possible electrical short in the coaxial cable, or an RAU problem. {ET149} Port 5 Cable Fault. Possible electrical short in the coaxial cable, or an RAU problem. {ET150} Port 6 Cable Fault. Possible electrical short in the coaxial cable, or an RAU problem. {ET151} Port 7 Cable Fault. Possible electrical short in the coaxial cable, or an RAU problem. {ET152} Port 8 Cable Fault. Possible electrical short in the coaxial cable, or an RAU problem. {ET153} Port 1 Trip. The Remote Unit is drawing too much current. {ET154} Port 2 Trip. The Remote Unit is drawing too much current. {ET155} Port 3 Trip. The Remote Unit is drawing too much current. {ET156} Port 4 Trip. The Remote Unit is drawing too much current. {ET157} Port 5 Trip. The Remote Unit is drawing too much current. {ET158} Port 6 Trip. The Remote Unit is drawing too much current. {ET159} Port 7 Trip. The Remote Unit is drawing too much current. {ET160} Port 8 Trip. The Remote Unit is drawing too much current. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A C.4 Faults for RAUs Table C-4 Faults for RAUs Message Number Description Reason/Action {RF01} Software error occurred and recovered. If this happens repeatedly, replace the RAU. {RF02} Software error occurred and recovered. If this happens repeatedly, replace the RAU. {RF03} Software error occurred and recovered. If this happens repeatedly, replace the RAU. {RF04} Software reset occurred and recovered, or firmware download. If this happens repeatedly, replace the RAU. {RF05} Software error occurred and recovered. If this happens repeatedly, replace the RAU. {RF06} Problem detected in the RAU. Contact LGC Wireless Support for more information. {RF07} RAU power cycle. RAU power cycle. {RF08} Problem detected in the RAU. Contact LGC Wireless Support for more information. {RF09} Invalid band. The RAU doesn't support programmed band. Check the RAU type against the band programmed in the hub. {RF10} Low input DC voltage. Check the coaxial cable for high RF loss. Try another Hub port. If the fault persists, replace the RAU. If the fault clears, mark the Hub port as unusable and replace the Hub when possible. {RF11} Hardware Failure (DL PLL Band 1). Cycle power once. If the fault persists, replace the RAU. {RF12} Hardware Failure (DL PLL Band 2). Cycle power once. If the fault persists, replace the RAU. {RF13} Hardware Failure (DL PLL Band 3). Cycle power once. If the fault persists, replace the RAU. {RF14} Hardware Failure (UL PLL Band 1). Cycle power once. If the fault persists, replace the RAU. {RF15} Hardware Failure (UL PLL Band 2). Cycle power once. If the fault persists, replace the RAU. {RF16} Hardware Failure (UL PLL Band 3). Cycle power once. If the fault persists, replace the RAU. {RF17} Hardware Failure (PA Band 1). Cycle power once. If the fault persists, replace the RAU. {RF18} Hardware Failure (PA Band 2). Cycle power once. If the fault persists, replace the RAU. {RF19} Hardware Failure (PA Band 3). Cycle power once. If the fault persists, replace the RAU. {RF20} Hardware Failure (UL Pilot). Cycle power once. If the fault persists, replace the RAU. {RL21} Commanded Out-of-service (Band 1). Band 1 commanded out-of-service by User. Command In-Service on Band 1 to restore service. {RL22} Commanded Out-of-service (Band 2). Band 2 commanded out-of-service by User. Command In-Service on Band 2 to restore service. {RL23} Commanded Out-of-service (Band 3). Band 3 commanded out-of-service by User. Command In-Service on Band 3 to restore service. {RF24} Problem detected in the RAU. Contact LGC Wireless Support for more information. {RX25} Commanded shutdown (Band 1). Check the status of hub to which the RAU is connected. {RX26} Commanded shutdown (Band 2). Check the status of hub to which the RAU is connected. {RX27} Commanded shutdown (Band 3). Check the status of the hub to which the RAU is connected. {RF28} Internal shutdown (Band 1). RAU Fault condition in band 1 path (or common path). {RF29} Internal shutdown (Band 2). RAU Fault condition in band 2 path (or common path). {RF30} Internal shutdown (Band 3). RAU Fault condition in band 3 path (or common path). {RF31} Problem detected in the system. Contact LGC Wireless Support for more information. {RF32} Problem detected in the RAU. Contact LGC Wireless Support for more information. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-9 CONFIDENTIAL C.5 Warning/Status Messages for Fusion Main/SingleStar Hubs Warning Messages Warnings alert you to conditions that indicate possible service impact. Warnings are displayed in the Messages pane in red lettering. Before addressing warnings, ensure that all faults are resolved. Take appropriate action to resolve the warnings, as indicated in the following tables. NOTE: AdminBrowser v0000007 or higher displays events (faults, warnings, or status messages) depending on your view preference. To change your view preference, refer to Section 3.3.2, “View Preference,” on page 3-10. Status Messages Status messages alert you to conditions that are important, but generally do not impact service. Status messages alert you to conditions that are important, but generally do not impact service. Status messages are displayed in the Messages pane in blue lettering. NOTE: AdminBrowser v0000007 or higher displays events (faults, warnings, or status messages) depending on your view preference. To change your view preference, refer to Section 3.3.2, “View Preference,” on page 3-10. NOTE: The icons displayed in the system status tree assume that there are no other faults, warnings, or status present. In Table C-5, the message number is in the following form: [Mnn]/X where nn equals the message number, and X equals the default of either Status (S) or Warning (W). C-10 CONFIDENTIAL InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A Table C-5 Warnings/Status Messages for Fusion Main/SingleStar Hubs Message Number/ Default Description Reason/Action [M01]/S Fan 1 failure. Check the fan for rotation, air flow blockage, and dust. Replace the Hub on high temperature warning. [M02]/S Fan 2 failure. Check the fan for rotation, air flow blockage, and dust. Replace the Hub on high temperature warning. [M03]/S 54 VDC Pwr Supply Fan failure. Check the fan for rotation, air flow blockage, and dust. Replace the Hub on high temperature warning. [M04]/W 5 VDC Monitor. DC power out of range, replace the Hub. [M05]/W 9 VDC Monitor. DC power out of range, replace the Hub. [M06]/W 54 VDC Monitor. DC power out of range, replace the Hub. [M07]/W 3 VDC Monitor. DC power out of range, replace the Hub. [M08]/W 12 VDC Monitor. DC power out of range, replace the Hub. [M09]/W Temperature High. Reduce ambient temperature, check for air flow blockage, fan rotation. [M10]/W -5 VDC Monitor. DC power is out of range, replace the Hub. [M11]/W High laser current. Output laser failure possible, replace the Hub when possible. [M12]/W DL path loss is too high Replace the Hub. [M13]/S Low input optical (Port 1). Check the uplink fiber. [M14]/S Low input optical (Port 2). Check the uplink fiber. [M15]/S Low input optical (Port 3). Check the uplink fiber. [M16]/S Low input optical (Port 4). Check the uplink fiber. [M17]/S Hardware failure (Test Tone PLL Band 1). Unable to perform DL system test. [M18]/S Hardware failure (Test Tone Too High Band 1). Unable to perform DL system test. [M19]/S Hardware failure (Test Tone Too Low Band 1). Unable to perform DL system test. [M20]/W Overdrive limiter active (Band 1). Reduce input signal power to avoid potential component damage. [M21]/W CEMark limiter at maximum (Band 1). Reduce input signal power to avoid drop in system gain. [M22]/W No DL test tone (Band 1). Hub DL gain is low. [M23]/S No UL test tone (Band 1). Hub UL path gain is low. [M24]/S Problem detected in the system. Contact LGC Wireless Support for more information. [M25]/S Hardware failure (Test Tone PLL Band 2). Unable to perform DL system test. Replace the hub when possible. [M26]/S Hardware failure (Test Tone Too High Band 2). Unable to perform DL system test. Replace the hub when possible. [M27]/S Hardware failure (Test Tone Too Low Band 2). Unable to perform DL system test. Replace the hub when possible. [M28]/W Overdrive limiter active (Band 2). Reduce input signal power to avoid potential component damage. [M29]/W CEMark limiter at maximum (Band 2). Reduce input signal power to avoid drop in system gain. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-11 CONFIDENTIAL Table C-5 C-12 CONFIDENTIAL Warnings/Status Messages for Fusion Main/SingleStar Hubs Message Number/ Default Description [M30]/W No DL test tone (Band 2). Hub DL path gain is low. [M31]/S No UL test tone (Band 2). Hub UL path gain is low. [M32]/S Problem detected in the system. Contact LGC Wireless Support for more information. [M33]/S Hardware failure (Test Tone PLL Band 3). Unable to perform DL system test. [M34]/S Hardware failure (Test Tone Too High Band 3). Unable to perform DL system test. [M35]/S Hardware failure (Test Tone Too Low Band 3). Unable to perform DL system test. [M36]/W Overdrive limiter active (Band 3). Reduce input signal power to avoid potential component damage. [M37]/W CEMark limiter at maximum (Band 3). Reduce input signal power to avoid drop in system gain. Reason/Action [M38]/W No DL test tone (Band 3). Hub DL path gain is low. [M39]/S No UL test tone (Band 3). Hub UL path gain is low. [M40]/S Problem detected in the Hub. Contact LGC Wireless Support for more information. [M41]/W Port 1 No DL test tone (Band 1). Hub/Port DL path gain is low. [M42]/W Port 2 No DL test tone (Band 1). Hub/Port DL path gain is low. [M43]/W Port 3 No DL test tone (Band 1). Hub/Port DL path gain is low. [M44]/W Port 4 No DL test tone (Band 1). Hub/Port DL path gain is low. [M45]/W Port 5 No DL test tone (Band 1). Hub/Port DL path gain is low. [M46]/W Port 6 No DL test tone (Band 1). Hub/Port DL path gain is low. [M47]/W Port 7 No DL test tone (Band 1). Hub/Port DL path gain is low. [M48]/W Port 8 No DL test tone (Band 1). Hub/Port DL path gain is low. [M49]/W Port 1 No DL test tone (Band 2). Hub/Port DL path gain is low. [M50]/W Port 2 No DL test tone (Band 2). Hub/Port DL path gain is low. [M51]/W Port 3 No DL test tone (Band 2). Hub/Port DL path gain is low. [M52]/W Port 4 No DL test tone (Band 2). Hub/Port DL path gain is low. [M53]/W Port 5 No DL test tone (Band 2). Hub/Port DL path gain is low. [M54]/W Port 6 No DL test tone (Band 2). Hub/Port DL path gain is low. [M55]/W Port 7 No DL test tone (Band 2). Hub/Port DL path gain is low. [M56]/W Port 8 No DL test tone (Band 2). Hub/Port DL path gain is low. [M57]/W Port 1 No DL test tone (Band 3). Hub/Port DL path gain is low. [M58]/W Port 2 No DL test tone (Band 3). Hub/Port DL path gain is low. [M59]/W Port 3 No DL test tone (Band 3). Hub/Port DL path gain is low. [M60]/W Port 4 No DL test tone (Band 3). Hub/Port DL path gain is low. [M61]/W Port 5 No DL test tone (Band 3). Hub/Port DL path gain is low. [M62]/W Port 6 No DL test tone (Band 3). Hub/Port DL path gain is low. [M63]/W Port 7 No DL test tone (Band 3). Hub/Port DL path gain is low. [M64]/W Port 8 No DL test tone (Band 3). Hub/Port DL path gain is low. [M65]/S No UL test tone (Band 1). Hub/Port UL path gain is low. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A Table C-5 Warnings/Status Messages for Fusion Main/SingleStar Hubs Message Number/ Default Description Reason/Action [M66]/S Problem detected in the Hub. Contact LGC Wireless Support for more information. [M67]/S Problem detected in the Hub. Contact LGC Wireless Support for more information. [M68]/S No UL test tone (Port 4/Band 1). Hub/Port UL path gain is low. [M69]/S No UL test tone (Band 2). Hub/Port UL path gain is low. [M70]/S No UL test tone (Port 2/Band 2). Hub/Port UL path gain is low. [M71]/S No UL test tone (Port 3/Band 2). Hub/Port UL path gain is low. [M72]/S No UL test tone (Port 4/Band 2). Hub/Port UL path gain is low. [M73]/S No UL test tone (Band 3). Hub/Port UL path gain is low. [M74]/S No UL test tone (Port 2/Band 3). Hub/Port UL path gain is low. [M75]/S No UL test tone (Port 3/Band 3). Hub/Port UL path gain is low. [M76]/S No UL test tone (Port 4/Band 3). Hub/Port UL path gain is low. [M77]/S Problem detected in the Hub. Contact LGC Wireless Support for more information. [M78]/S Problem detected in the Hub. Contact LGC Wireless Support for more information. [M79]/S Problem detected in the Hub. Contact LGC Wireless Support for more information. [M80]/S Problem detected in the Hub. Contact LGC Wireless Support for more information. [M81]/W Port 1 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [M82]/W Port 2 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [M83]/W Port 3 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [M84]/W Port 4 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [M85]/W Port 5 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [M86]/W Port 6 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [M87]/W Port 7 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [M88]/W Port 8 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [M89]/W Port 1 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem on more than one port, replace the Hub, otherwise replace the RAU. [M90]/W Port 2 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [M91]/W Port 3 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-13 CONFIDENTIAL Table C-5 C-14 CONFIDENTIAL Warnings/Status Messages for Fusion Main/SingleStar Hubs Message Number/ Default Description Reason/Action [M92]/W Port 4 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [M93]/W Port 5 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [M94]/W Port 6 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [M95]/W Port 7 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [M96]/W Port 8 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [M97]/W Port 1 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check the RAU. [M98]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check the RAU. [M99]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check the RAU. [M100]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check the RAU. [M101]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check the RAU. [M102]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check the RAU. [M103]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check the RAU. [M104]/W Port 8 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check the RAU. [M105]/W Port 1 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [M106]/W Port 2 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [M107]/W Port 3 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [M108]/W Port 4 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [M109]/W Port 5 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [M110]/W Port 6 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [M111]/W Port 7 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [M112]/W Port 8 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A C.6 Warning/Status Messages for System CPUs In Table C-6, the message number is in the following form: [Snn]/X where nn equals the message number, and X equals the default of either Status (S) or Warning (W). Table C-6 Warning/Status Messages for System CPUs Message Number/ Default Description Reason/Action [S01]/W Alarm Input 1. Check equipment connected to alarm input 1. [S02]/W Alarm Input 2. Check equipment connected to alarm input 2. [S03]/W Alarm Input 3. Check equipment connected to alarm input 3. [S04]/S Problem detected in the system CPU. Retrieve the TTL and erase. [S05]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S06]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S07]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S08]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S09]/S Time-tagged Log is full. Retrieve the TTL and erase. [S10]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S11]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S12]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S13]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S14]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S15]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. [S16]/S Problem detected in the system CPU. Contact LGC Wireless Support for more information. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-15 CONFIDENTIAL C.7 Warning/Status Messages for Fusion Expansion Hubs Table C-7 C-16 CONFIDENTIAL Warning/Status Message for Fusion Expansion Hubs Message Number /Default Description Reason/Action [E01]/W Alarm Input 1. Check the equipment connected to alarm input 1. [E02]/W Alarm Input 2. Check the equipment connected to alarm input 2. [E03]/W Alarm Input 3. Check the equipment connected to alarm input 3. [E04]/S Problem detected in the EH. Contact LGC Wireless Support for more information. [E05]/W SNMP Trap #1. TBD. [E06]/W SNMP Trap #2. TBD. [E07]/W SNMP Trap #3. TBD. [E08]/S Problem detected in the EH. Contact LGC Wireless Support for more information. [E09]/S Fan 1 failure. Check the fan for proper rotation, air flow blockage, and dust accumulation. Replace the Hub on high temperature warning. [E10]/S Fan 2 failure. Check the fan for proper rotation, air flow blockage, and dust accumulation. Replace the Hub on high temperature warning. [E11]/W -5 VDC Monitor. DC power out of range, replace the Hub. [E12]/W 5 VDC Monitor. DC power out of range, replace the Hub. [E13]/W 9 VDC Monitor. DC power out of range, replace the Hub. [E14]/W 54 VDC Pwr Supply failure. DC port power supply out of range, replace the Hub. [E15]/W 3 VDC Monitor. DC power out of range, replace the Hub. [E16]/W 12 VDC Monitor. DC power out of range, replace the Hub. [E17]/W Temperature High. Reduce the ambient temperature, check for air flow blockage, fan rotation. [E18]/W DL path exceeds maximum gain. If the problem is common to more than one port, replace the MH, otherwise check the EH. [E19]/W DL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different MH port. If the problem is on more than one port, replace the EH, otherwise replace the RAU. [E20]/W Hardware Failure (High UL Pilot). Cycle power once. If the fault persists, replace the EH. [E21]/W Hardware Failure (Low UL Pilot). Cycle power once. If the fault persists, replace the EH. [E22]/W Low optical input power. Check the downlink fiber connection. [E23]/W High laser current. Contact LGC Wireless Support for more information. [E24]/S Problem detected in the EH. Contact LGC Wireless Support for more information. [E25]/W Port 1 No DL test tone (Band 1). Hub/Port DL path gain is low. [E26]/W Port 2 No DL test tone (Band 1). Hub/Port DL path gain is low. [E27]/W Port 3 No DL test tone (Band 1). Hub/Port DL path gain is low. [E28]/W Port 4 No DL test tone (Band 1). Hub/Port DL path gain is low. [E29]/W Port 5 No DL test tone (Band 1). Hub/Port DL path gain is low. [E30]/W Port 6 No DL test tone (Band 1). Hub/Port DL path gain is low. [E31]/W Port 7 No DL test tone (Band 1). Hub/Port DL path gain is low. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A Table C-7 Warning/Status Message for Fusion Expansion Hubs (continued) Message Number /Default Description Reason/Action [E32]/W Port 8 No DL test tone (Band 1). Hub/Port DL path gain is low. [E33]/W Port 1 No DL test tone (Band 2). Hub/Port DL path gain is low. [E34]/W Port 2 No DL test tone (Band 2). Hub/Port DL path gain is low. [E35]/W Port 3 No DL test tone (Band 2). Hub/Port DL path gain is low. [E36]/W Port 4 No DL test tone (Band 2). Hub/Port DL path gain is low. [E37]/W Port 5 No DL test tone (Band 2). Hub/Port DL path gain is low. [E38]/W Port 6 No DL test tone (Band 2). Hub/Port DL path gain is low. [E39]/W Port 7 No DL test tone (Band 2). Hub/Port DL path gain is low. [E40]/W Port 8 No DL test tone (Band 2). Hub/Port DL path gain is low. [E41]/W Port 1 No DL test tone (Band 3). Hub/Port DL path gain is low. [E42]/W Port 2 No DL test tone (Band 3). Hub/Port DL path gain is low. [E43]/W Port 3 No DL test tone (Band 3). Hub/Port DL path gain is low. [E44]/W Port 4 No DL test tone (Band 3). Hub/Port DL path gain is low. [E45]/W Port 5 No DL test tone (Band 3). Hub/Port DL path gain is low. [E46]/W Port 6 No DL test tone (Band 3). Hub/Port DL path gain is low. [E47]/W Port 7 No DL test tone (Band 3). Hub/Port DL path gain is low. [E48]/W Port 8 No DL test tone (Band 3). Hub/Port DL path gain is low. [E49]/W Port 1 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [E50]/W Port 2 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [E51]/W Port 3 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [E52]/W Port 4 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [E53]/W Port 5 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [E54]/W Port 6 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [E55]/W Port 7 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [E56]/W Port 8 DL path loss is high. If the problem is on more than one port, replace the Hub. Switch the cable connection to a different hub port until the Hub can be replaced. [E57]/W Port 1 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [E58]/W Port 2 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-17 CONFIDENTIAL Table C-7 C-18 CONFIDENTIAL Warning/Status Message for Fusion Expansion Hubs (continued) Message Number /Default Description Reason/Action [E59]/W Port 3 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [E60]/W Port 4 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [E61]/W Port 5 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [E62]/W Port 6 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [E63]/W Port 7 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [E64]/W Port 8 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem is on more than one port, replace the Hub, otherwise replace the RAU. [E65]/W Port 1 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check RAU. [E66]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check RAU. [E67]/W Port 3 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check RAU. [E68]/W Port 4 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check RAU. [E69]/W Port 5 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check RAU. [E70]/W Port 6 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check RAU. [E71]/W Port 7 UL path exceeds maximum gain. If problem is common to more than one port, replace the Hub, otherwise check RAU. [E72]/W Port 8 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub, otherwise check RAU. [E73]/W Port 1 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [E74]/W Port 2 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [E75]/W Port 3 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [E76]/W Port 4 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [E77]/W Port 5 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [E78]/W Port 6 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [E79]/W Port 7 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. [E80]/W Port 8 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output. InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A C.8 Warning /Status Messages for RAUs In Table C-8, the message number is in the following form: [Rnn]/X where nn equals the message number, and X equals the default of either Status (S) or Warning (W). Table C-8 Warning/Status Messages for RAUs Message Number Default Description Reason/Action [R01]/W Temperature High. Check RAU location for excessive temperature; check for air flow blockage and/or incorrect installation. Move the RAU to a cooler environment. [R02]/W No communications from Hub. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem persists, replace the RAU. [R03]/W DL RF path loss is too high. Check the cable for high RF loss. Switch the cable connection to a different hub port. If the problem persists, replace the RAU. [R04]/W DL RF path exceeds maximum gain. Check the Hub for proper operation; switch the cable connection to a different hub port. If the problem persists, replace the RAU. [R05]/S DL RF path problem (Band 1). Unable to complete the DL system end-to-end test, replace the RAU when possible. [R06]/S DL RF path problem (Band 2). Unable to complete the DL system end-to-end test, replace the RAU when possible. [R07]/S DL RF path problem (Band 3). Unable to complete the DL system end-to-end test, replace the RAU when possible. [R08]/S System test required. Run system test. [R09]/W Antenna Disconnected. Check RAU antenna connection; re-run system test. [R10]/S UL RF path problem (Band 1). Unable to complete the UL system end-to-end test, replace the RAU when possible. [R11]/S UL RF path problem (Band 2). Unable to complete the UL system end-to-end test, replace the RAU when possible. [R12]/S UL RF path problem (Band 3). Unable to complete the UL system end-to-end test, replace the RAU when possible. [R13]/S Problem detected in the RAU. Contact LGC Wireless Support for more information. [R14]/S Problem detected in the RAU. Contact LGC Wireless Support for more information. [R15]/S Problem detected in the RAU. Contact LGC Wireless Support for more information. [R16]/S Problem detected in the RAU. Contact LGC Wireless Support for more information. Help Hot Line (U.S. only): 1-800-530-9960 D-620610-0-20 Rev A C-19 CONFIDENTIAL C-20 CONFIDENTIAL InterReach Fusion Installation, Operation, and Referencer Manual D-620610-0-20 Rev A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 124 Page Mode : UseOutlines Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:3e5d17f3-2975-45b8-94e0-000c996799ba Producer : AFPL Ghostscript 8.54 Modify Date : 2007:11:07 10:16:40-08:00 Create Date : 2006:10:16 23:27:12Z Creator Tool : PrimoPDF http://www.primopdf.com Metadata Date : 2007:11:07 10:16:40-08:00 Document ID : 389ca82d-6005-11db-0000-2c192fc0c76c Format : application/pdf Title : fusionBOOK.book Creator : Steve Hailes Author : Steve HailesEXIF Metadata provided by EXIF.tools