ADC Telecommunications PSM0804A FlexWave™ Prism - Cellular 40 Watt User Manual 2
ADC Telecommunications Inc FlexWave Prism - Cellular 40 Watt Users Manual 2
Contents
- 1. Users Manual 1
- 2. Users Manual 2
- 3. Users Manual 3
- 4. Users Manual 4
Users Manual 2
Using t he Prism EMS Viewing Alarm Details I n m any inst ances, a page will have an Alarm Status colum n, which indicat es whet her an alarm is act ive. I f an alarm is act ive, t here will be a Minor or Major link ( as shown in Figure 19) t hat you click t o open a dialog t hat defines t he act ive alarm . The background color of t he Alarm Status cell also indicat es t he alarm level. Figure 19. Alarm Link For inform at ion on t he Alarm indicat or in t he Syst em Tree, see “ Syst em Tree” on page 41. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 45 © 2011 ADC Telecom m unicat ions, I nc. How t o Use t he EMS Graphical User I nt erface Sorting Tables You can change t he order of a t able’s cont ent s by applying an alphanum eric sort on a colum n ( see Figure 20) . To t oggle a colum n by ascending or descending order, click in t he colum n heading. Figure 20. Sorting Tables in the GUI Page 46 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using t he Prism EMS F OLLOWING THE P ROCEDURES IN THIS D OCUMENT This sect ion t ells you how t o use t his docum ent t o use t he FlexWave Prism EMS t o configure and m anage Prism devices. Starting a Procedure All procedures in t his docum ent assum e t hat you have already logged in t o t he EMS as described in “ Access t he EMS” on page 57. Modifying Parameters I n general, t he procedures in t his docum ent end by having you click OK or Apply t o accept changes or input . When an operat ion com plet es, an Operation completed m essage displays, such as t he one shown in Figure 21. I f an error m essage displays, follow t he screen prom pt s. You can click Refresh t o updat e t he dat a being shown. Figure 21. Operation Completed Message FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 47 © 2011 ADC Telecom m unicat ions, I nc. Following t he Procedures in t his Docum ent Selecting Menu Items I n t he Prism user docum ent at ion, when a procedure requires t hat you select a sequence of m enu it em s, a right - angle sym bol separat e t he it em s. For exam ple, in t he following graphic, “ click Users > Manage Users” indicat es t hat in t he Syst em Menu bar you select Users, and t hen in t he Users list , select Manage Users. Page 48 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using t he Prism EMS U SING THE H ELP E MBEDDED IN THE GUI The following sect ions t ell you how t op access and use t he em bedded Prism Help m odule. Accessing Help I n t he Orient at ion Links, click Help > Contents. Prism Help is cont ext sensit ive, which m eans t hat t he Help t opic t hat opens will pert ain t o t he current view in t he EMS View Fram e. I n t he following exam ple, t he Help Topic for t he Get Information page has opened. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 49 © 2011 ADC Telecom m unicat ions, I nc. Using t he Help Em bedded in t he GUI Navigating Help The Help Module is designed like a book t o m ake it easy t o navigat e. Using the Contents Tab The default view opens wit h t he Contents navigat ion t ool open. I n t he following exam ple, you can see where t he Get Information t opic falls wit hin t he order of cont ent s. • Click on any of t he Contents links t o go t o t he specified t opic. • Click on t he book icons t o open/ close t he chapt ers. Page 50 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using t he Prism EMS You can also use t he Show in Contents but t on t o show where a t opic falls wit hin t he book hierarchy: Using the Orientation Links and Buttons You can use t he int eract ive orient at ion links in t he t opic header. These links show where t he t opic falls wit hin a chapt er. Click on t he links in t he t opic header t o m ove back one st ep in t he book hierarchy. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 51 © 2011 ADC Telecom m unicat ions, I nc. Using t he Help Em bedded in t he GUI You can also use t he Page Up but t on, Page Down but t on, Print but t on, and Bookm ark but t on t o bookm ark a t opic. Using the Index Tab Click Index t o open t he Index panel. At t he t op of t he Index panel is t he alpha- num eric orient at ion t ool. I n t his exam ple, t he let t er D is select ed, which result s in only t hose indexed words t hat st art wit h Page 52 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using t he Prism EMS “ D” t o display, in alphabet ic order. Click on any of t he links t o go t o t he t opic t hat has t he indexed t erm in it . To m ove up/ down or left / right t o change t he orient at ion of t he t ext in t he I ndex panel, use t he navigat ion arrows. Using the Search Tab Click Search t o open t he Search panel. At t he t op of t he Search panel is a t ext box in which you ent er t he t erm for which you want t o search. I n t his exam ple t he user is searching for t he word “ passband.” To act ivat e t he search, click t he Go but t on. The Search panel is populat ed wit h links t o t he t opics t hat cont ain t he word “ passband” and are ordered from t op down in order of probabilit y of which t opic will cont ain t he t opic for which you are searching. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 53 © 2011 ADC Telecom m unicat ions, I nc. Using t he Help Em bedded in t he GUI I nt ent ionally Blank Page Page 54 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 INITIAL FLEXWAVE PRISM SYSTEM SETUP Topics Page Minim um EMS Syst em Requirem ent s ........................................................................................ 56 Access t he EMS ..................................................................................................................... 57 Set Session Tim eout ............................................................................................................... 59 Set Dat e and Tim e ................................................................................................................. 60 Set Net work Connect ions ........................................................................................................63 Configure Basic Host Unit Propert ies ......................................................................................... 64 Label t he PRU/ URU................................................................................................................. 66 Label t he Host Opt ical Port s..................................................................................................... 67 Label PRU/ URU Opt ical Port s ................................................................................................... 70 Configure DART Links ............................................................................................................. 71 Classic DART Models ......................................................................................................... 75 800 APAC iDEN Classic DART ........................................................................................ 75 800 SMR Classic DART ................................................................................................. 75 900 SMR Classic ......................................................................................................... 76 2100 AWS Classic DART............................................................................................... 76 Cellular Classic DART................................................................................................... 77 PCS Classic DART........................................................................................................ 77 SuperDART Models ........................................................................................................... 79 700 Lower ABC SuperDART .......................................................................................... 79 700 UpperC SuperDART ............................................................................................... 79 2100 AWS SuperDART ................................................................................................. 79 EGSM 900 SuperDART ................................................................................................. 79 GSM 1800 SuperDART ................................................................................................. 80 PCS SuperDART .......................................................................................................... 80 UMTS SuperDART ....................................................................................................... 80 DART St art and St op Frequencies ....................................................................................... 81 Set t he Forward and Reverse Delays......................................................................................... 82 Using t he Linked DARTs Delay Table ................................................................................... 83 Filt ering t he Linked DARTs Delay Table ................................................................................ 84 Configure Host Forward Gain ................................................................................................... 85 Configure Host Reverse Gain ................................................................................................... 88 Configure Rem ot e Forward Gain ............................................................................................... 91 Configure Reverse I nput Power Levels ...................................................................................... 94 The st eps provided in t his chapt er configure a basic Prism syst em t hat includes: • one Host Unit ( Host ) • at least one Prism Rem ot e Unit ( PRU) . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 55 © 2011 ADC Telecommunications, Inc. Minim um EMS Syst em Requirem ent s MINIMUM EMS SYSTEM REQUIREMENTS The com put er t hat you use t o rem ot ely access t he EMS m ust m eet t he following m inim um requirem ent s: • Windows 2000 or Windows XP operat ing syst em • I nt ernet Explorer version 7.x or FireFox 3.6 • Net work I nt erface Card ( NI C) • Et hernet cable wit h RJ- 45 connect ors. The EMS dat abase can also be accessed rem ot ely using an SNMP m anager. I n t his case, t he user int erface varies depending on t he SNMP m anager, but t he underlying param et ers, param et er values, and alarm s are t he sam e as in t he st andard EMS int erface. Page 56 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up ACCESS THE EMS NOTE: In the default configuration, the Craft port has a DHCP server that assigns an IP address to the computer that is connected. You should therefore have your network interface configured for DHCP, or configured with a static IP address in the same subnet, where the default is 192.168.0.1/24. To allow t he EMS popup and alarm screens t o funct ion correct ly, do one of t he following: • • Disable t he popup blocker for your web browser. Ent er t he syst em I P address in t he web browser’s t rust ed sit es list . Use an Et hernet CAT 5 cable ( st raight or crossover) wit h RJ- 45 connect ors t o connect a lapt op t o t he Craft port of t he Host . Connect your com put er and st art a web browser. I n t he web browser URL box, ent er t he following IP address: 192.168.0.1 RJ-45 Connector Detail 77073-075 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 57 © 2011 ADC Telecom m unicat ions, I nc. Access t he EMS When t he Welcome to ADC FlexWave Prism & URH and ADC InterReach Spectrum window opens: I n t he User Name box, t ype t he user nam e provided by ADC or by t he Net work Adm inist rat or. The default user nam e is admin. I n t he Password box, t ype t he password provided by ADC or by t he Net work Adm inist rat or. The default password is adc123. Once inst allat ion is com plet e, users can be added and passwords can be changed. For furt her inform at ion, see “ Users” on page 203. Click Log in t o open t he default page, which com prises t he elem ent s list ed below. • The Syst em Tree will be populat ed wit h inst alled devices, but no device will be select ed. • I n t he EMS View Fram e, t he default page displays when t he Host is select ed in t he Syst em Tree. Page 58 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up SET SESSION TIMEOUT NOTE: This feature is accessible only by a user logged in to the EMS as the admin user. To access t he Set Session Timeout page, in t he Syst em Menu bar, click Special Features > Set Session Timeout. I n t he Session Idle Time box, ent er in m inut es how long t he EMS session can be idle before a forced log out occurs; t he value m ust be bet ween 10 and 60 m inut es. The default is 30 m inut es. Click Apply. Once t he syst em execut es t he com m and, m essage displays. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 an Operation completed Page 59 © 2011 ADC Telecom m unicat ions, I nc. Set Dat e and Tim e SET DATE AND TIME The following rules apply t o t he syst em t im e and dat e: • The support ed dat e and t im e range is from 1 January 2005 00: 00: 00 ( 12 AM) t o 31 Decem ber 2037 23: 59: 59 ( 11: 59: 59 PM) , where January is 1 and Decem ber is 12. • Tim e zone and day light savings are not support ed. • All PRUs synchronize t im e wit h t he m anaging Host at t he t im e t he connect ed PRU is discovered. The dat e and t im e on t he PRUs t hen synchronize t o t he Host and do not drift . • I f t he syst em dat e or t im e is changed while a PRU is out of com m unicat ion wit h t he Host ( for exam ple, loss of power or scheduled m aint enance) , once com m unicat ion is reest ablished it will t ake up t o 10 m inut es for t he PRU t o display t he updat ed dat e or t im e. • I f t he difference bet ween t he set t im e and t he present t im e is great er t han t he session t im e out set t ing, t he user will be logged out . For exam ple, if t he Session Idle Time is set t o 10 m inut es, and t he t im e set in t his procedure is 11: 10 AM but it is act ually 11: 30 AM, t here is a 20 m inut e difference, which t riggers t he Session Idle Time and t he user will be logged out . NOTE: It can take up to 17 minutes before the updated time or date to take effect in connected Remote Units. NOTE: You can set the date and time at any time independent from one another. For example, to change the time for daylight savings, open the System Date and Time page, click on the hour shown in the System Time box, increase or decrease the hour by one, and then click Apply. Page 60 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up D o t he follow in g t o se t t h e da t e a n d t im e : To access t he Set Date and Time page, in t he Syst em Menu bar, click System Configuration > Set Date and Time. To change t he dat e, click t he … icon aft er t he Date (YYYY/MM/DD) box. I n t he Calendar t hat opens, do t he following: I n t he Mont h list , select t he m ont h. I f necessary, use t he right arrow t o adj ust t he year higher. I n t he calendar, select t he dat e. Click Close. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 61 © 2011 ADC Telecom m unicat ions, I nc. Set Dat e and Tim e I n t he Time (HH:MM:SS) box, ent er t he syst em t im e in t he 24- hour clock HH: MM: SS form at ( for exam ple, t o set t he syst em t im e t o 5: 19: 56 PM, you would ent er 17:19:56) . I n t he Set Date and Time page, verify t he dat e and t im e showing in t he System Date and System Time fields. Click Apply. Once t he syst em execut es t he com m and, m essage displays. Page 62 © 2011 ADC Telecommunications, Inc an Operation completed FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up SET NETWORK CONNECTIONS To access t he Set Network Connections page, in t he Syst em Menu bar, click System Configuration > Set Network Connections. Use t he Networking Mode list t o specify t he m ode under which I P addresses are assigned t o t he Host Craft and Net work port s. A single I P address defines t he syst em . This I P address is assigned t o t he Host eit her st at ically or by t he DHCP server on t he NOC. No user set t ing/ I P configurat ion is required for t he PRUs—I P addresses for connect ed PRUs are aut o assigned. • DHCP—t his m ode indicat es t hat t he Host is a DHCP client and expect s an I P address t o be assigned by an ext ernal DHCP server t hrough a net work Et hernet connect or. The Host Craft port has a DHCP server t hat can be used t o com m unicat e wit h t he Host direct ly, and from which you can access t he EMS. • Static—t he default m ode for t he Craft Port, wit h a default I P address of 192.168.0.1. The Static Networking Mode allows you t o set an I P address for t he Host and connect ed Rem ot e Unit s t hat do not change unless you m anually change t hem . I f you change a port t o Static Networking Mode, t he address fields are enabled. Ot herwise you cannot change t he net work addresses. I f you set a port t o Static Networking Mode, t hen do t he following: I n t he IP Address box, ent er a new I P address for t he syst em , in t he form at of xxx.xxx.xxx.xxx. I n t he Subnet Mask box, ent er a new Subnet Mask address for t he syst em , in t he form at of xxx.xxx.xxx.xxx. I n t he Gateway box, ent er a new Gat eway address for t he syst em , in t he form at of xxx.xxx.xxx.xxx. Click Apply. Once t he syst em execut es t he com m and, m essage displays. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 an Operation completed Page 63 © 2011 ADC Telecom m unicat ions, I nc. Configure Basic Host Unit Propert ies CONFIGURE BASIC HOST UNIT PROPERTIES I n t he Syst em Tree, click on t he Host icon. I n t he Unit Menu bar, click Unit Configuration > Edit Properties, t o open t he Unit Configuration > Edit Properties page. I n t he Name box, ent er an ident ifying nam e for t he Host . The Name m ust st art wit h an alphabet ical charact er, cont ain bet ween 5 and 40 charact ers ( alphanum eric or underscore only) , and cont ain no spaces. ( Opt ional) The SeRF board on each Host and Rem ot e cont ains t he clock for t hat unit . At t he Rem ot e, t he reference is a clock derived from t he Host clock. The 10 MHz Reference Clock default is Internal. You can change t he 10 MHz Reference Clock set t ing t o External, which allows you t o frequency lock t he clock t o an ext ernal 10 MHz reference. CAUTION! When using the 10 MHz external reference clock, the signal must be connected to the Host before enabling the clock in the software. If an external 10MHz reference clock is selected for operation, but is not present or outside of the frequency range of 10MHz +/- 5ppm, communication between the Host and Remote over the optical fiber will fail. I n t he System Card Output Clock list , select one of t he following: • 10 MHz t o set t he Host as t he Syst em Card Out put Clock. • Off t o disable t he Syst em Card Out put Clock. Unless your syst em requires t he 10 MHz out put , it is best t o leave t he System Card Output Clock disabled, as t his set t ing saves power and lowers em issions. • 30.72 MHz is not applicable t o a Prism syst em and should not be select ed. Page 64 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up ( Opt ional) Use t he Notes box t o ent er not es specific t o t his Host . You can ent er up t o 256 charact ers; all keyboard charact ers can be used. Click Apply. Once t he syst em execut es t he com m and, m essage displays. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 an Operation completed Page 65 © 2011 ADC Telecom m unicat ions, I nc. Label t he PRU/ URU LABEL THE PRU/URU I n t he Syst em Tree, click t he icon of t he PRU/ URU whose propert ies you want t o change. I n t he Unit Menu bar, click Unit Configuration > Edit Properties, t o open t he Unit Configuration > Edit Properties page for t he select ed PRU/ URU. I n t he Name box, ent er an ident ifying nam e for t he PRU/ URU. The Name m ust st art wit h an alphabet ical charact er, cont ain bet ween 5 and 40 charact ers ( alphanum eric or underscore only) , and cont ain no spaces. Leave t he Capacity set t ing as is. CAUTION! The Capacity setting pertains to the PRU/URU Remote SeRF Interface (RSI) board and the number of RF groups available to the Remote Unit. This parameter is set during manufacturing and should be changed only when the RSI board has been replaced. See “Set the Capacity for a New Remote Unit RSI Board” on page 162. ( Opt ional) Use t he Notes box t o ent er not es specific t o t he select ed PRU/ URU. You can ent er up t o 256 charact ers; all keyboard charact ers can be used. Click Apply. Once t he syst em execut es t he com m and, m essage displays. Repeat t his process for each PRU/ URU in t he syst em . Page 66 © 2011 ADC Telecommunications, Inc an Operation completed FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up LABEL THE HOST OPTICAL PORTS CAUTION! If fibers must be moved or reconfigured at any time during installation or setup, follow the steps in “Moving or Reconfiguring Fibers” on page 122. There can be up t o eight Host SeRF opt ical port s t hat correspond t o t he eight physical port s on t he Host . I n t his sect ion, you should label t he Host SeRF Opt ical port s t o provide for easier off- sit e m anagem ent . 77152-009 I n t he Syst em Tree, click on a Host icon. I n t he Unit Menu bar, click Unit Configuration > Configure Optical Ports, t o open t he Unit Configuration > Configure Optical Ports page. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 67 © 2011 ADC Telecom m unicat ions, I nc. Label t he Host Opt ical Port s I n t he SFP Name box, ent er a label for t he select ed Opt ics port . The SFP Name m ust st art wit h an alphabet ical charact er, cont ain 5 t o 32 charact ers ( alphanum eric or underscore only) , and cont ain no spaces. The default SFP Name is UNKNOWN_SFPNAME. Click Apply. Once t he syst em execut es t he com m and, m essage displays. an Operation completed The Configure Optical Ports t able provides t he following inform at ion. • SFP Number—syst em assigned num ber ( from 1 t o 8) for t he Opt ical port s • SFP Name—see St ep 3 on page 68. • In/Out—used for cascading, which is not support ed in t his release. The Host will t herefore always be set as Out ( indicat es t hat t he forward link for t he connect ed SFP is going away from t he Host ) and t he SFPs for all Rem ot e Unit s will always be set as In. • Optics Type – LongRange—26 dB – IntermediateRange—18 dB) • Wavelength (nm)—num ber displayed is t he wavelengt h t ransm it t ed t hrough t his port : – Non- duplex and WDM configurat ions 1550 nm fwd 1310 nm rev – CWDM configurat ions can be one of eight wavelengt hs: 1470 nm 1550 nm 1490 nm 1570 nm 1510 nm 1590 nm 1530 nm 1610 nm Page 68 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up • Tx Power (dBm)—launch power level in dBm of forward pat h signal. – LongRange ( LR) m inim um is - 2 dBm m axim um is 3 dBm . – I nt erm ediat eRange ( I R) m inim um is - 5 dBm m axim um is 0 dBm . • Rx Power (dBm)—receive power level in dBm of reverse pat h signal, which incorporat es t he launch power of t he Rem ot e Unit SFP plus all opt ical losses ( insert ion losses, fiber cable loss, and so fort h) . – LongRange ( LR) m inim um is - 27 dBm m axim um is - 9 dBm . – I nt erm ediat eRange ( I R) m inim um is - 18 dBm m axim um is 0 dBm . • Remote Name or Host Name—when a Host Unit is select ed in t he Syst em Tree, t he Configure Optical Ports t able provides a colum n for Remote Name, which is nam e of t he Rem ot e Unit connect ed t o t his Opt ics port . When a Rem ot e Unit is select ed in t he Syst em Tree, t he Configure Optical Ports t able provides a colum n for t he Host Name, which is t he nam e of t he Host connect ed t o t his Opt ics port . • Alarm Status—whet her an alarm is act ive. I f an alarm is act ive, t here will be a Minor or Major link t hat you click t o open a dialog t hat defines t he act ive alarm , as described in “ Viewing Alarm Det ails” on page 45. The background color of t he Alarm Status cell also indicat es t he alarm level ( see “ Alarm Color Codes” on page 44) . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 69 © 2011 ADC Telecom m unicat ions, I nc. Label PRU/ URU Opt ical Port s LABEL PRU/URU OPTICAL PORTS I n t he Syst em Tree, click on a PRU/ URU icon. I n t he Unit Menu bar, click Unit Configuration > Configure Optical Ports, t o open t he Unit Configuration > Configure Optical Ports page. I n t he SFP Name box, ent er a label for t he select ed Opt ics port . The SFP Name m ust st art wit h an alphabet ical charact er, cont ain bet ween 5 and 32 charact ers ( alphanum eric or underscore only) , and cont ain no spaces. The default SFP Name is UNKNOWN_SFPNAME. Click Apply. Once t he syst em execut es t he com m and, m essage displays. Repeat t his process for each PRU/ URU in t he syst em . an Operation completed The Configure Optical Ports t able provides t he sam e inform at ion as what is shown for a Host Unit —see “ Label t he Host Opt ical Port s” on page 67. Page 70 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up CONFIGURE DART LINKS “ Linking” est ablishes an associat ion in soft ware bet ween a part icular Host DART and a part icular Rem ot e DART, enabling t he t wo DARTs t o act as an operat ional unit in providing one RF band. There are four pre- requisit es t o t his procedure: • The Host DART and Rem ot e DART m ust be connect ed t hrough t he opt ical fiber and be com m unicat ing wit h each ot her. • To link t he Rem ot e Unit DARTs t o t he DARTs in a Host Unit , t he DARTs m ust be t he sam e t ype e ( such as, Cellular t o Cellular) . • SuperDARTs and Classic DARTS do not operat e wit h each ot her. Link a SuperDART t o a SuperDART and a Classic DART t o a Classic DART. • There m ust be a sufficient num ber of fiber t im eslot s available in order t o accom m odat e t he request ed passband ( for exam ple, PCS A band requires 3 t im eslot s) . I n t he Configure DART Links page, all Rem ot e DARTs are list ed t hat have t he sam e band as t he select ed Host DART. A link is est ablished by select ing a Rem ot e DART t o be paired wit h t he Host DART, and t hen clicking t he Linked box. To provide for an RF Sim ulcast , a Single Host DART can be linked t o up t o eight Rem ot e DARTs. Do t he following t o est ablish DART links: To access t he Configure DART Links page, in t he Syst em Menu bar, click System Configuration > Configure DART Links. NOTE: For information on the Linked DARTs table at the bottom of the Configure DART Links page, see “Viewing the Linked DARTs Report” on page 105. You use t he Configure Bands panel t o configure t he Host for DART linking, and t he Remote Parameters panel t o configure t he Rem ot e Unit . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 71 © 2011 ADC Telecom m unicat ions, I nc. Configure DART Links I n t he Host Parameters panel, set t he following param et ers: I n t he DART list , select t he Host DART t hat you want t o link t o t he Rem ot e Unit DART. I n t he DART Name box, ent er a nam e for t he DART, which m ust st art wit h an alphabet ical charact er, cont ain bet ween 5 and 32 charact ers ( alphanum eric or underscore only) , and cont ain no spaces. Use t he Passband colum n t o set t he passband for t he select ed DART. • I f you are configuring a Classic DART, t hen refer t o t he passband select ion t able in t he corresponding sect ion: “ 800 APAC iDEN Classic DART” on page 75 “ 800 SMR Classic DART” on page 75 “ 900 SMR Classic” on page 76 “ 2100 AWS Classic DART” on page 76 “ Cellular Classic DART” on page 77 “ PCS Classic DART” on page 77 The following figure shows t he passband select ions for t he 2100 AWS Classic DART, which are described in “ 2100 AWS Classic DART” on page 76. Page 72 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up • I f you are configuring a SuperDART, in t he Passband colum n, click on t he Configure link, and t hen in t he passband select ion window t hat opens, set t he passband according t o t he rules specified for each SuperDART t ype: “ 700 Lower ABC SuperDART” on page 79 “ 700 UpperC SuperDART” on page 79 “ 2100 AWS SuperDART” on page 79 “ EGSM 900 SuperDART” on page 79 “ GSM 1800 SuperDART” on page 80 “ PCS SuperDART” on page 80 “ UMTS SuperDART” on page 80 The following figure shows t he passband select ions for a PCS SuperDART, which are described in “ PCS SuperDART” on page 80. The Frequency t able provides a read- only t abular view of forward and reverse pat hs. • I n t he Diversity list , select whet her t he DART is t o be configured as Diversity or Non Diversity. For a diversit y applicat ion, one DART will be configured Non Diversity for t he prim ary FWD/ REV pat h signal and t he ot her DART will be configured Diversity. This select ion t herefore det erm ines whet her t he DART Module being configured will carry t he prim ary or secondary REV ( uplink) RF pat h. • For dual DART configurat ions, such as dual- pcs, sm r800/ sm r900 and dual- aws, bot h DARTs m ust have DART Diversity Status set t o Non Diversity. • I n t he Input Source list , select whet her t he Wireless Operat or input will be from t he BDA or BTS. Input Source det erm ines whet her Syst em Test uses ext ernal RF ( BTS) or int ernal RF ( BDA) t o t est t he forward pat h. However, t his release does not support int ernal t one generat ion. Consequent ly, set t ing t he Input Source as eit her BDA or BTS assum es an ext ernal RF signal. Default is BTS. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 73 © 2011 ADC Telecom m unicat ions, I nc. Configure DART Links I n t he Remote Parameters t able, set t he following param et ers: I n t he Remote Id list , select t he Rem ot e Unit whose DART you are linking t o t he Host DART. I n t he DART list , select t he Rem ot e Unit DART t hat you are linking. I n t he DART Name box, ent er a nam e for t he DART, which m ust st art wit h an alphabet ical charact er, cont ain bet ween 5 and 32 charact ers ( alphanum eric or underscore only) , and cont ain no spaces. Select t he Linked box. Click Apply. The Linked DARTS t able at t he bot t om of t he page updat es wit h t he new link. Repeat St ep t hrough St ep 4 for each Host and PRU/ URU DART pairing. NOTE: Each link takes approximately 1 minute to establish. Page 74 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up Classic DART Models The following sect ions describe t he Prism Classic DART opt ions. 800 APAC iDEN Classic DART Table 13 list s t he passband select ions for 800 APAC iDEN Classic DARTs. Table 13. 800 APAC iDEN Classic DART Passband Selection Name Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) 800 APAC iDEN 851 - 870 806 - 825 The 800 APAC iDEN DART also support s t he SMR Low and SMR Low Wide passbands. The 800 APAC iDEN Classic DART can be linked t o a DART of t he sam e t ype and t o an 800 SMR Classic DART ( as long as t he passband is eit her SMR Low or SMR Low Wide) . Table 14 specifies support ed linking bet ween 800 SMR Classic DARTs and 800 APAC iDEN Classic DARTs. Table 14. Linking 800 SMR Classic DARTs and 800 APAC iDEN Classic DARTs Host DART PRU/URU DART Passbands 800APAC 800APAC low, wide, apac 800APAC 800SMR low, wide 800SMR 800APAC low, wide 800SMR 800smr low, wide 800 SMR Classic DART Table 15 list s t he passband select ions for 800 SMR Classic DARTs. Table 15. 800 SMR Classic DART Passband Selections Name Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) SMR Low 862 - 869 817 - 824 SMR Low Wide 851 - 869 806 - 824 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 75 © 2011 ADC Telecom m unicat ions, I nc. Configure DART Links 900 SMR Classic Table 16 list s t he passband select ions for 900 SMR Classic DARTs. Table 16. NOTE: 900 SMR Classic DART Passband Selections Name Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) SMR High 935 - 940 896 - 901 SMR High/Paging 935 - 941 896 - 902 When installed in a PRU, the 900 SMR Remote Classic DART supports only the SMR High passband. 2100 AWS Classic DART Table 17 list s t he passband select ions for 2100 AWS Classic DARTs. Table 17. Page 76 © 2011 ADC Telecommunications, Inc 2100 AWS Classic DART Passband Selection Name Downlink Frequency Range (MHz) Uplink Frequency Range (MHz) 2110 - 2120 1710 - 1720 A+B 2110 - 2130 1710 - 1730 A+B+C 2110 - 2135 1710 - 1735 A+B+C+D 2110 - 2140 1710 - 1740 A+B+C+D+E 2110 - 2145 1710 - 1745 2120 - 2130 1720 - 1730 B+C 2120 - 2135 1720 - 1735 B+C+D 2120 - 2140 1720 - 1740 B+C+D+E 2120 - 2145 1720 - 1745 B+C+D+E+F 2120 - 2155 1720 - 1755 2130 - 2135 1730 - 1735 C+D 2130 - 2140 1730 - 1740 C+D+E 2130 - 2145 1730 - 1745 C+D+E+F 2130 - 2155 1730 - 1755 2135 - 2140 1735 - 1740 D+E 2135 - 2145 1735 - 1745 D+E+F 2135 - 2155 1735 - 1755 2140 - 2145 1740 - 1745 E+F 2140 - 2155 1740 - 1755 2145 - 2155 1745 - 1755 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up Cellular Classic DART Table 18 list s t he passband select ions for Cellular Classic DARTs. Table 18. NOTE: Cellular Classic DART Passband Selections Name Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) A'' + A 869 - 880 824 - 835 870 - 880 825 - 835 A'' + A + A’ 869 - 891.5 824 - 846.5 A’ 890 - 891.5 845 - 846.5 880 - 890 835 - 845 B’ 891.5 - 894 846.5 - 849 B + B’ 880 - 894 835 - 849 A'' + A + B + A' + B’ 869 - 894 824 - 849 A+B 825 - 845 870 - 890 The Cellular Classic Remote DART supports the same passbands as the Cellular Classic Host DART. However, the LNA or Duplexer installed in the Remote Unit can restrain which passbands are supported. PCS Classic DART Table 19 list s t he passband select ions for PCS Classic DARTs. Table 19. PCS Classic DART Passband Selections Passband Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) Passband Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) A1 1930 - 1935 1850 - 1855 E+F+C2 1965 - 1982.5 A2 1935 - 1940 1855 - 1860 C1+G + H 1982.5 - 2000 1902.5 - 1920 A3 1940 - 1945 1860 - 1865 A+D 1930 - 1950 1850 - 1870 B1 1950 - 1955 1870 - 1875 A2+A3+D+B1 1935 - 1955 1855 - 1875 B2 1955 - 1960 1875 - 1880 A3+D+B1+B2 1940 - 1960 1860 - 1880 B3 1960 - 1965 1880 - 1885 D+B 1945 - 1965 1865 - 1885 C3 1975 - 1980 1895 - 1900 B+E 1950 - 1970 1870 - 1890 C4 1980 - 1985 1900 - 1905 B2+B3+E+F 1955 - 1975 1875 - 1895 C5 1985 - 1990 1905 - 1910 B3+E+F+C3 1960 - 1980 1880 - 1900 1945 - 1950 1865 - 1870 E+F+C3+C4 1965 - 1985 1885 - 1905 1965 - 1970 1885 - 1890 F+C 1970 - 1990 1890 - 1910 1970 - 1975 1890 - 1895 C+G 1975 - 1995 1895 - 1915 1990 - 1995 1910 - 1915 C4+C5+G + H 1980 - 2000 1900 - 1920 1995 - 2000 1915 - 1920 B3+E+F+C2 1960 - 1982.5 1880 - 1902.5 1885 - 1902.5 C2 1975 - 1982.5 1895 - 1902.5 A+D+B1 1930 - 1955 1850 - 1875 C1 1982.5 - 1990 1902.5 - 1910 A2+A3+D+B1+B2 1935 - 1960 1855 - 1880 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 77 © 2011 ADC Telecom m unicat ions, I nc. Configure DART Links Table 19. PCS Classic DART Passband Selections Passband Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) Passband Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) A1+A2 1930 - 1940 1850 - 1860 A3+D+B 1940 - 1965 1860 - 1885 A2+A3 1935 - 1945 1855 - 1865 D+B+E 1945 - 1970 1865 - 1890 A3+D 1940 - 1950 1860 - 1870 B+E+F 1950 - 1975 1870 - 1895 D+B1 1945 - 1955 1865 - 1875 B2+B3+E+F+C3 1955 - 1980 1875 - 1900 B1+B2 1950 - 1960 1870 - 1880 B3+E+F+C3+C4 1960 - 1985 1880 - 1905 B2+B3 1955 - 1965 1875 - 1885 E+F+C 1965 - 1990 1885 - 1910 B3+E 1960 - 1970 1880 - 1890 F+C+G 1970 - 1995 1890 - 1915 E+F 1965 - 1975 1885 - 1895 C+G + H 1975 - 2000 1895 - 1920 F+C3 1970 - 1980 1890 - 1900 B2+B3+E+F+C2 1955 - 1982.5 1875 - 1902.5 C3+C4 1975 - 1985 1895 - 1905 A+D+B1+B2 1930 - 1960 1850 - 1880 C4+C5 1980 - 1990 1900 - 1910 A2+A3+D+B 1935 - 1965 1855 - 1885 C5+G 1985 - 1995 1905 - 1915 A3+D+B+E 1940 - 1970 1860 - 1890 G+H 1990 - 2000 1910 - 1920 D+B+E+F 1945 - 1975 1865 - 1895 F+C2 1970 - 1982.5 1890 - 1902.5 B+E+F+C3 1950 - 1980 1870 - 1900 C1+G 1982.5 - 1995 1902.5 - 1915 B2+B3+E+F+C3+C4 1955 - 1985 1875 - 1905 1930 - 1945 1850 - 1865 B3+E+F+C 1960 - 1990 1880 - 1910 A2+A3+D 1935 - 1950 1855 - 1870 E+F+C+G 1965 - 1995 1885 - 1915 A3+D+B1 1940 - 1955 1860 - 1875 F+C+G + H 1970 - 2000 1890 - 1920 D+B1+B2 1945 - 1960 1865 - 1880 A+D+B 1930 - 1965 1850 - 1885 1950 - 1965 1870 - 1885 A2+A3+D+B+E 1935 - 1970 1855 - 1890 B2+B3+E 1955 - 1970 1875 - 1890 A3+D+B+E+F 1940 - 1975 1860 - 1895 B3+E+F 1960 - 1975 1880 - 1895 D+B+E+F+C3 1945 - 1980 1865 - 1900 E+F+C3 1965 - 1980 1885 - 1900 B+E+F+C3+C4 1950 - 1985 1870 - 1905 F+C3+C4 1970 - 1985 1890 - 1905 B2+B3+E+F+C 1955 - 1990 1875 - 1910 1975 - 1990 1895 - 1910 B3+E+F+C+G 1960 - 1995 1880 - 1915 C4+C5 +G 1980 - 1995 1900 - 1915 E+F+C+G + H 1965 - 2000 1885 - 1920 C5+G + H 1905 - 1920 1985 - 2000 Page 78 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up SuperDART Models The following sect ions describe t he Prism SuperDART opt ions. 700 Lower ABC SuperDART The 700 Lower ABC SuperDART support s t he following subbands: A, B, C. Table 20 list s t he passband select ions for 700 Lower ABC SuperDARTs. 700 Lower ABC SuperDART Passband Selection Table 20. Name Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) 728 - 734 698 - 704 734 - 740 704 - 710 740 - 746 710 - 716 700 UpperC SuperDART The 700 UpperC SuperDART support s t he following passband: Upper C. Table 21 list s t he passband select ions for 700 ABC SuperDARTs. Table 21. 700 UpperC SuperDART Passband Selection Name Downlink Frequency Uplink Frequency Range (MHz) Range (MHz) UpperC 746 - 756 776 - 786 2100 AWS SuperDART You can select any num ber of t he subbands based on t he lim it at ions specified below. • The 2100 AWS SuperDART support s t he following passbands: A, B, C, D, E, F. • You can select up t o t wo non- cont iguous set s of subbands, but t here m ust be at least a 5 MHz gap bet ween t he bands. • The St art and St op frequencies are in t he range of 2110MHz - 2155MHz. EGSM 900 SuperDART The EGSM 900 SuperDART support s t he select ion of a St art and St op frequency for t he passband in t he range of 925MHz - 960MHz. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 79 © 2011 ADC Telecom m unicat ions, I nc. Configure DART Links GSM 1800 SuperDART You can select a St art and St op frequency for t he passband in t he frequency range of 1805 MHz - 1880 Mhz. PCS SuperDART PCS SuperDARTs support t he following subbands: A, B, C, D, E, F, G, H, A1, A2, A3, B1, B2, B3, C1, C2, C3, C4, C5. You can select any num ber of t he subbands based on t he lim it at ions specified below: • The subband A cannot be chosen in conj unct ion wit h A1, A2, or A3. • The subband B cannot be chosen in conj unct ion wit h B1, B2, or B3. • The subband C cannot be chosen in conj unct ion wit h C1, C2, C3, C4, or C5. • The subbands C1 and C2 cannot be chosen in conj unct ion wit h t he subbands C, C3, C4, or C5. • The subbands C3, C4, and C5 cannot be chosen in conj unct ion wit h t he subbands C, C1, or C2. • Up t o t wo non- cont iguous set s of subbands can be select ed, and t here m ust be m ore t han a 5 MHz gap bet ween t he bands. The PCS SuperDART support s t he following St art and St op frequencies: • The PCS RF SuperDART support s t he select ion of a St art and St op frequency for t he passband as list ed in Table 19. • The PCS RF SuperDART St art and St op frequencies are in t he range of 1930MHz - 2000MHz. UMTS SuperDART You can select a St art and St op frequency for t he passband in t he frequency range of 2110 MHz - 2170 MHz. Page 80 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up DART Start and Stop Frequencies Host SuperDARTs support t he select ion of a St art and St op frequency for t he passband or for t he select ion of subbands ( up t o t wo st art - st op frequency pairs m ay be select ed as long as t he t wo pairs are at least 5 MHz apart and one is lim it ed t o 39 MHz and t he ot her is lim it ed t o 25 MHz) . NOTE: Start/Stop frequencies and subbands may not be used at the same time. Table 22 list s t he support ed st art - st op frequency ranges for SuperDARTs. Table 22. Supported SuperDART Stop/Start Frequency Ranges Frequency Range (MHz) Timeslots 12 18 25 39 45 75 12 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 81 © 2011 ADC Telecom m unicat ions, I nc. Set t he Forward and Reverse Delays SET THE FORWARD AND REVERSE DELAYS NOTE: The system comes up with a default delay. Once linking is complete, the system will calculate the actual delay. The initial parameters that are set may therefore be out of range. If necessary, correct the delay within the available range. NOTE: If part of a simulcast, ensure that all links in the simulcast are set to the same delay value. NOTE: For information on the Linked DARTs Delay table at the bottom of the page, see “Using the Linked DARTs Delay Table” on page 83. To access t he Configure Delay page, in t he Syst em Menu bar, click System Configuration > Configure Delay. I n t he Remote Parameters t able, do t he following: I n t he Remote Id list , select t he Rem ot e Unit for which you want t o configure t he delay set t ings. I n t he DART list , select t he DART for which you want t o configure t he delay set t ings. Only t hose DARTS t hat have been linked will be available in t he DART list . The following inform at ion is populat ed in t he Remote Parameters t able, which corresponds t o t he Rem ot e Unit and DART t hat you have select ed. • Forward Delay ( s) —t he Forward Range in m icroseconds available for t he select ed DART • Forward Delay Range ( s) —t he Forward Delay Range in m icroseconds for t he select ed DART • Reverse Delay ( s) —t he Reverse Delay in m icroseconds available for t he select ed DART • Reverse Delay Range ( s) —t he Reverse Delay Range in m icroseconds for t he select ed DART • Passband—t ype of passband provided by t he DART I f necessary, change t he Forward Delay and t he Reverse Delay: • Forward Delay ( s) box—ent er t he act ual delay in m icroseconds t hat will be applied t o t he RF forward pat h signal. The Forward Delay Range ( s) field displays valid set t ings for t he Forward Delay. • Reverse Delay ( s) box—ent er t he act ual delay in m icroseconds t hat will be applied t o t he RF reverse pat h signal. The Reverse Delay Range ( s) field displays valid set t ings for t he Reverse Delay. Page 82 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up Click Apply. The Operation complete m essage displays, and t he Remote Parameters t able clears so you can set t he delay for anot her DART. Repeat St ep 2 t hrough St ep 3 for each DART. Using the Linked DARTs Delay Table The Linked DARTs Delay t able provides t he following inform at ion: • Host colum ns—ident ifies t he Host in t he link – DART Id—num ber of t he Host slot in which t he DART is inst alled – DART Name—user- defined nam e for t he Host DART • Remote colum ns—ident ifies t he Rem ot e and it s elem ent s – Id—Unit I D of PRU/ URU based upon layered address; see “ Unit I dent ificat ion” on page 43 – Name—user- defined label for t he PRU/ URU – DART Id—PRU/ URU slot num ber in which t he DART is inst alled – DART Name—user- defined nam e for t he Rem ot e DART – Forward Delay ( s) —user request ed FWD RF pat h delay in m icroseconds – Reverse Delay ( s) —user request ed REV RF pat h delay in m icroseconds • Common colum ns—configurat ion set t ings com m on t o t he Host and Rem ot e( s) – Passband—t ype of passband provided by t he DART. – Frequency (MHz)—passband frequency of t he DART FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 83 © 2011 ADC Telecom m unicat ions, I nc. Set t he Forward and Reverse Delays Filtering the Linked DARTs Delay Table I n t he Filter panel View list , select a filt er t o be applied t o t he t able. In the contains box, ent er filt er crit eria. Click Filter t o apply t he filt er. I n t he following exam ple, t he Linked DARTs Delay t able has been filt ered t o show only t hose Host Unit s wit h a DART Id t hat cont ains “ 2” . Page 84 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up CONFIGURE HOST FORWARD GAIN NOTE: Digital power measurements are inaccurate when ALC is active. Follow t hese st eps t o set t he Forward Gain value for t he Host DART. Det erm ine what t he Host DART Forward Gain should be. Use a signal generat or and spect rum analyzer t o m easure t he uplink at t enuat ion from t he Host t o t he BTS, and t he FWD power at t he Host from t he BTS t o det erm ine unloaded power level. The Host DART expect s signal levels from -25 t o +5 dBm. I f t he fully loaded signal is + 5 dBm , t hen t he DART forward gain should be set t o 0 dB, if t he fully loaded signal is - 25 dBm , t hen t he DART Forward Gain should be set t o 31 dB. The equat ion is: DART Forward Gain = 5 - fully Loaded Base St at ion Signal CAUTION! If you are setting up the system when no calls are going through, you must allow headroom for a fully loaded forward path. For CDMA protocols, the difference from unloaded to fully loaded is typically 8dB, so if the unloaded signal is -15dBm, then the fully loaded input would be -7 dBm and the Host Forward Gain should be set to 5-(-7) = 12 dB. The same rules applies for GSM carriers, except that the unloaded to loaded is determined by the equation 10*log10(# RF Channels). So if there are 4 GSM RF Channels, then the loaded forward path is 6 dB above unloaded. If sufficient headroom is not present, then the LPA can be over-powered causing a Loss Of Service. CAUTION! When configured correctly, the Host DART Forward input can handle peaks of 14dB above the BTS signal level. For example, if the fully loaded CDMA carrier is -25dBm, then peaks up to -11 dBm can be handled (CDMA peak to average is typically 10-12 dB). If the peaks exceed the 14 dB of headroom, then Automatic Level Control (ALC) will occur to prevent over-driving the A/D Converter. NOTE: In the EMS GUI, the reverse path gain range for Classic DARTs is 5 to 36 dB, which indicates actual reverse path system gain. If you set this gain through the SNMP SET commands, then the gain range is 0 to 31 dB, which maps to the actual GUI/system reverse path gain range of 5 to 36 dB. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 85 © 2011 ADC Telecom m unicat ions, I nc. Configure Host Forward Gain I n t he EMS, do t he following t o set t he Host Forward Gain param et ers: To access t he Configure Host Forward Gain page, in t he Syst em Menu bar, click System Configuration > Configure Host Forward Gain. I n t he Host Parameters t able DART list , select t he Host DART t hat you want t o configure. Ot her inform at ion in t he Host Parameters t able is updat ed t o show set t ings for t he select ed DART. I n t he DART Mode list , select one of t he following: • Standby—forces t he RF funct ion t o be m ut ed in t he Host and it s linked Rem ot e Unit . • Normal—allows t he syst em t o operat e norm ally ( RF funct ion not forced t o be m ut ed) , assum ing all ot her syst em com ponent s are in proper working order. ( Default set t ing.) I n t he Fwd Gain (dB) list , select t he Forward Gain value of 0 t o 31 dB, based upon t he fully loaded forward pat h signal level from t he Base St at ion. I n t he Power Level Mode list , select one of t he following: NOTE: • Snapshot—provides a “ snap- shot ” or current RF m easurem ent for t he select ed Rem ot e Unit DART ( default set t ing) . • Max Hold—ret ains t he m axim um values for peak and peak average, and t he m inim um values for m inim um average since t he last Max Hold Reset. The Power Level Mode is disabled if the: • • • DART Operating mode is set to Standby DART Pass Band (Timeslots) parameter is set to Undefined (default) DART Diversity Status is set to Diversity. Page 86 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up I f you set t he Power Level Mode t o Max Hold, you can click Reset Max Hold t o reset t he Max Hold values. The Host Forward Gain Settings t able updat es wit h t he new set t ings. The Host Parameters t able provides t he following inform at ion: • Peak Power (dBm)—shows t he highest ( peak) power level reached by t he Host DART • Average Power (dBm)—shows t he average power level reached by t he Host DART • Minimum Power (dBm)—shows t he m inim um power level reached by t he Host DART Click Apply. • Once t he syst em execut es t he com m and, an Operation completed m essage displays. • The Host Forward Gain Settings t able at t he bot t om of t he page is updat ed wit h t he new set t ings. Repeat St ep b on page 86 t hrough St ep g for each Host DART. For inform at ion on t he Host Forward Gain Settings t able, see “ Viewing t he Host RF Report ” on page 108. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 87 © 2011 ADC Telecom m unicat ions, I nc. Configure Host Reverse Gain CONFIGURE HOST REVERSE GAIN When set t ing t he Reverse Gain value for t he Host DART, t he following rules m ust be observed: • The Reverse Gain set t ing can be used t o overcom e RF int erfacing losses from t he Host DART t o t he BTS/ BDA. I f you want unit y reverse pat h gain and t he losses t o t he BTS/ BDA are 20 dB, t hen t he Reverse Gain should be set t o 20 dB. • Sim ulcast changes t he act ual REV gain level by 10log( n) where n = t he num ber of sim ulcast links. For exam ple, if REV gain is set t o 10dB in a 2: 1 sim ulcast configurat ion, t he act ual REV gain is only 7dB ( 10dB - 3dB) . I f REV gain is set t o 20dB in a 4: 1 sim ulcast , t he act ual gain is 14dB ( 20dB - 6dB) . Follow t hese st eps t o set t he Reverse Gain value for t he Host DART. To access t he Configure Host Reverse Gain page, in t he Syst em Menu bar, click System Configuration > Configure Host Reverse Gain. I n t he Host Parameters t able DART list , select t he Host DART t hat you want t o configure. The DART Name colum n is populat ed wit h t he user- defined nam e for t he select ed DART. I n t he Reverse Gain Mode list , select t he algorit hm t hat should be used t o add at t enuat ion for a sim ulcast group t o prevent clipping because of t oo st rong a signal. • Mode 1 (Noise Floor Matching)—opt im izes t he reverse pat h dynam ic range bet ween sim ulcast nodes. For Prism / URU, t he gains are reduced by 10* log10( N) . This is t he default for syst em s running Prism EMS 7.1. • Mode 2 (Legacy Prism/URH)—reduces t he gain by 20* log10( N) . This is t he default set t ing for syst em s upgraded from 6.0. Set t he Additive Gain (dB) value t o achieve t he required gain from t he input t o t he Rem ot e Unit t o t he out put of t he Host DART. The range is 0 t o 31 dB. Page 88 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up I n t he Gain Mode list , select one of t he following: • Normal—no increase t o t he gain set t ing. • High—t he gain set t ings for Classic DARTs increase 2dB wit h a 1dB im provem ent in t he Noise Figure and t he gain set t ing for SuperDart s increase by 6 dB wit h a 2dB im provem ent in t he Noise Floor. Click Apply. The Host Parameters and Host Reverse Gain Settings t ables are updat ed wit h t he new configurat ion. Repeat St ep 2 t hrough St ep 6 for each Host DART. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 89 © 2011 ADC Telecom m unicat ions, I nc. Configure Host Reverse Gain The Host Reverse Gain Settings t able has t he following colum ns. • DART Id—ident ifies t he Host DART by t he slot in which it is inst alled, which can be from 1 t hrough 8. • DART Name—ident ifies t he DART by it s user- defined nam e. • Reverse Gain Mode—whet her t he Reverse Gain Mode is Mode 1 (Noise Floor Matching) or Mode 2 (Legacy Prism/URH). • Additive Gain (dB)—gain from t he input t o t he Rem ot e Unit t o t he out put of t he Host DART. The range is 0 t o 31 dB • Calculated Reverse System Gain (dB)—shows t he end- t o- end gain based on t he addit ive gain, gain m ode, and num ber of Rem ot e Unit s in t he sim ulcast group. • Noise Floor (dBm/30kHz rbw)—shows t he noise level for t he configurat ion. The noise floor is t he m easure of t he signal creat ed from t he sum of all t he noise sources. • Gain Mode—whet her t he Gain Mode is Normal or High. • Passband—t ype of passband provided by t he DART. • Frequency (MHz)—passband frequency of t he DART. Page 90 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up CONFIGURE REMOTE FORWARD GAIN To access t he Configure Remote Forward Gain page, in t he Syst em Menu bar, click System Configuration > Configure Remote Forward Gain. I n t he Remote Parameters t able, do t he following: Use t he Host DART colum n t o ident ify t he connect ed Host . I n t he Remote Id list , select t he Rem ot e Unit for which you want t o set t he Forward Gain. I n t he Remote DART Mode list , set t he DART m ode: • Standby—forces t he RF funct ion t o be m ut ed in t he Host and it s linked Rem ot e Unit . • Normal—allows t he syst em t o operat e norm ally ( RF funct ion not forced t o be m ut ed) , assum ing all ot her syst em com ponent s are in proper working order. ( Default set t ing.) I n t he LPA Mode list , select Normal. A Prism Linear Power Am plifier ( LPA) is a high qualit y broadband RF am plifier used for achieving Prism product - rat ed power for t he Rem ot e Tx forward pat h spect rum RF. I n a dual- LPA syst em , bot h LPAs will have t he sam e LPA Mode set t ing. • Standby—forces t he RF funct ion t o be m ut ed in t he Host and it s linked Rem ot e Unit . ( Default set t ing.) • Normal—allows t he syst em t o operat e norm ally ( RF funct ion not forced t o be m ut ed) , assum ing all ot her syst em com ponent s are in proper working order. CAUTION! As soon as you set the LPA Operating Mode to Normal, RF transmission will start. Before you set the LPA Operating Mode to Normal, make sure that the antenna has been connected and the system is ready to transmit RF. For information on connecting the antenna, refer to the ADC® FlexWave Prism Remote Unit Installation Guide (ADCP-77-072). FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 91 © 2011 ADC Telecom m unicat ions, I nc. Configure Rem ot e Forward Gain I n t he Forward Gain list , select t he dB ( 0 t o 31) . The Forward Gain is t he act ual gain, not at t enuat ion, t hat will be applied t o t he RF forward pat h signal ( where 0 = 0 dB gain, 1 = 1 dB gain, and so fort h) . The Forward Gain is based on t he EI RP desired at t he ant enna. You t herefore need t o know how m uch cable, insert ion, and any ot her loss ( such as split t ers) exist bet ween t he Rem ot e Unit and t he ant enna. Set t he Forward Gain t o achieve t he required out put power level t o m eet t he EI RP of your RF link budget . Configure t he Host DART gain t o achieve + 5dB so t hat full scale out put can be achieved at t he Rem ot e. For furt her inform at ion, refer t o t he FlexWave Prism com m issioning guide. Refer t o t he following read- only fields for furt her inform at ion on t he select ed PRU/ URU: • NOTE: RF Power (dBm) colum n displays t he m easurem ent of t he RF power for t he LPA ident ified in t he LPA Num ber field. After a change in the DART Forward Gain, the EMS reflects the change in the RF Power column within 25 seconds, or if the Refresh button is used, within 12 seconds. • Max Power (dBm) colum n displays t he m axim um LPA power values. • VSWR colum n displays t he Volt age St anding Wave Rat io ( VSWR) for t he LPA. An LPA VSWR Fault occurs if t he VSWR m easurem ent exceeds t he t hreshold, which is 3: 1. Page 92 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up Click Apply. • Once t he syst em execut es t he com m and, an Operation completed m essage displays. • The Remote Forward Gain t able at t he bot t om of t he page is updat ed wit h t he new set t ings. Repeat for each PRU/ URU DART. For addit ional inform at ion, refer t o t he following: • For inform at ion on t he Remote Forward Gain Settings t able, see “ Viewing t he Rem ot e RF Report ” on page 109. • For inform at ion on t he LPA Reset but t on, see “ Reset t ing an LPA” on page 165. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 93 © 2011 ADC Telecom m unicat ions, I nc. Configure Reverse I nput Power Levels CONFIGURE REVERSE INPUT POWER LEVELS NOTE: Digital power measurements are inaccurate when ALC is active. To access t he Configure Reverse Input Power Levels page, in t he Syst em Menu bar, click System Configuration > Configure Reverse Input Power Levels. The read- Only colum ns in t he t able provide t he following inform at ion: • Peak Power (dBm)—shows t he highest ( peak) power level reached by t he DART • Average Power (dBm)—shows t he average power level reached by t he DART • Minimum Power (dBm)—shows t he m inim um power level reached by t he DART • Last Max Hold Reset Time—shows t he last t im e MAX Hold was reset . • Passband—t ype of passband provided by t he DART • Frequency (MHz)—passband frequency of t he DART I n t he Select Remote list , select t he PRU/ URU t hat you are configuring. The t able at t he bot t om of t he page displays power level values for t he select ed Rem ot e Unit and it s DARTs. I n t he Select DART list , do one of t he following: • Select a specific DART t o configure. I f you select a specific DART, t he t able at t he bot t om of t he page displays power level values for t he select ed DART. • Select All t o configure all t he DARTs t he sam e at t he sam e t im e. I f you select All, t he t able at t he bot t om of t he page displays power level values for t he select ed Rem ot e Unit and all it s DARTs. I n t he Gain Mode list , set t he High Gain m ode t o one of t he following: • Normal—effect s t he at t enuat ion of t he t em perat ure com pensat ion algorit hm ( default ) . • High—does not effect t he at t enuat ion of t he t em perat ure com pensat ion algorit hm . NOTE: When a Classic DART is in High Gain mode, the noise floor increases by 1 dBm. When a Super DART is in High Gain mode, the noise floor increases by 4 dBm. Page 94 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 I nit ial FlexWave Prism Syst em Set up I n t he Power Level Mode list , select one of t he following: • Snapshot—provides a “ snap- shot ” or current RF m easurem ent for t he select ed Rem ot e Unit DART ( default set t ing) . • Max Hold—ret ains t he m axim um values for peak and peak average, and t he m inim um values for m inim um average since t he last Max Hold Reset. Power Level Mode is disabled under any of t he following condit ions: • if t he DART Operating m ode is set t o Standby • if t he DART Pass Band (Timeslots) param et er is set t o Undefined ( default ) Click Apply. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 95 © 2011 ADC Telecom m unicat ions, I nc. Configure Reverse I nput Power Levels ( Opt ional) I f you set t he Power Level Mode t o Max Hold, you can click Reset Max Hold t o reset t he Max Hold values. Page 96 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 P ART I I I SYSTEM MANAGEMENT FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 97 © 2011 ADC Telecom m unicat ions, I nc. I nt ent ionally Blank Page Page 98 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 SYSTEM INFORMATION Topics Page Get I nform at ion ................................................................................................................... 100 Accessing Syst em Report s ............................................................................................... 101 Viewing t he Soft ware/ Firm ware Report ........................................................................ 101 Viewing t he Hardware I nvent ory Report ....................................................................... 102 Viewing t he Net work Report ....................................................................................... 104 Viewing t he Linked DARTs Report ................................................................................ 105 Viewing t he Delay Report ........................................................................................... 106 Viewing t he Fiber Report ............................................................................................ 107 Viewing t he Host RF Report ........................................................................................ 108 Viewing t he Rem ot e RF Report .................................................................................... 109 Viewing t he Alarm s Report ......................................................................................... 110 I FEU + RAU Report ................................................................................................... 111 Viewing t he All Report ............................................................................................... 112 Downloading a Report ..................................................................................................... 113 Get Opt ics I nform at ion ......................................................................................................... 116 Get Logs ............................................................................................................................. 118 This sect ion t ells you how t o get and m anage syst em inform at ion. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 99 © 2011 ADC Telecommunications, Inc. Get I nform at ion G ET I NFORMATION The Get Information page allows you t o view syst em inform at ion on one page. You can also view and download nine individual report s. To access t he Get Information page, in t he Syst em Menu bar, click System Information > Get Information. The following graphic shows t he default page in which Type is set t o System Inventory. The Get Information page has t he following elem ent s: • Type list —allows you t o select which report you want t o view. • Download but t on—downloads select ed “ Downloading a Report ” on page 113. NOTE: report to an at t ached PC. See The gray and white status bar at the top of the page indicates that the EMS is accessing the requested report. You do not need to select Download to see the report in the GUI. Page 100 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion Accessing System Reports You use t he Type list in t he Reports panel t o select t he t ype of report t hat you want t o download. The following sect ions describe t he report s t hat you can view and download. Viewing the Software/Firmware Report To access t he Software/Firmware report , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Software/Firmware. ( This is t he default set t ing.) The Software/Firmware t able provides t he following inform at ion: • Module Type—t ype of unit ( Host , PRU, or URU) . • Name—user- assigned nam e for t he unit . • Unit Id—ident ifies t he unit wit hin t he syst em ; see “ Unit I dent ificat ion” on page 43. • Version—version of inst alled soft ware/ firm ware. • Upgrade Status—t he following st at es can be seen. However, wit h t he except ion of Normal operation and Upgraded, t he st at es occur very quickly during t he corresponding act ion and are rarely viewed. – Normal operation – Upgrading – Upgrading reboot – Committing – Aborting – Recovering – Upgraded. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 101 © 2011 ADC Telecom m unicat ions, I nc. Get I nform at ion Viewing the Hardware Inventory Report To access t he Hardware Inventory report for t he Host and Rem ot e Unit ( s) , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Hardware Inventory. Page 102 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion The Hardware Inventory page has separat e t ables for each Host and Rem ot e Unit in t he syst em . For each Rem ot e Unit list ed, t here is also a corresponding LPA t able. Each unit is ident ified by nam e and I P address in a t it le bar at t he t op of t he t able. Each t able provides t he following inform at ion: • Module Type—ident ifies t he m odule by t ype, such as Syst em Card, DART, SeRF ( not used in t he LPA t able) . • Module Number ( LPA t able only) —ident ifies t he LPA. • Id—applicable t o t he DARTs and LPAs only; for furt her inform at ion see “ RF Module Capabilit ies and GUI Represent at ion” on page 21. • Date Code—dat e code for t he m odule. • Hardware Version—release version num ber for t he m odule. • Serial Number—serial num ber for t he m odule assigned during m anufact uring. • Part Number—Part Num ber for t he m odule assigned during m anufact uring ( not applicable t o t he LPA) . • Description ( LPA only) —band t ype of LPA/ LPA power in Wat t s. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 103 © 2011 ADC Telecom m unicat ions, I nc. Get I nform at ion Viewing the Network Report To access t he Network report , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Network. The Network Statistics t able provides t he following inform at ion: • Unit Id—ident ifies t he unit wit hin t he syst em ; see “ Unit I dent ificat ion” on page 43. • Port—ident ifies t he port – Host port s can be any of t he following: Net work Port Craft Port Swit ch Port – Rem ot e Unit port is indicat ed only as a Swit ch Port NOTE: A Switch Port is the CPU’s connection to the Ethernet switch that in turn communicates to the fibers. This shows how much traffic the unit is generating and consuming. • Rx Bytes—count of Receive Byt es. • Rx Packets—count of Receive Packet s. • RX FCS Errors—count of Receive FCS Errors. • Tx Bytes—count of Transm it Byt es. • Tx Packets—count of Transm it Packet s. Page 104 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion Viewing the Linked DARTs Report To access t he Linked DARTs report , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Link. The Linked DARTs t able provides t he following inform at ion: • Host colum ns—ident ifies t he Host and it s elem ent s – DART Id—num ber of t he Host slot in which t he DART is inst alled – DART Name—user- defined nam e for t he Host DART – SFP Id—port num ber of physical opt ical port where Host - Rem ot e opt ical fiber is connect ed on t he Host . – SFP Name—user- defined nam e for t he Opt ics port . • Remote colum ns—ident ifies t he Rem ot e and it s elem ent s – Id—Unit I D of PRU/ URU based upon layered address; see “ Unit I dent ificat ion” on page 43 – Name—user- defined label for t he PRU/ URU – SFP Id—ident ificat ion ( I d) of Rem ot e side SFP connect ed t oward t he Host DART ( can be from 1 t hrough 8) – SFP Name—user- defined nam e for t he Opt ics port – DART Id—PRU/ URU slot num ber in which t he DART is inst alled – DART Name—user- defined nam e for t he Rem ot e DART – Timeslots—num ber of t im eslot s assigned t o t he link. • Common colum ns—ident ify configurat ion set t ings t hat are com m on t o t he Host and connect ed Rem ot e( s) – Passband—t ype of passband provided by t he DART – Frequency—passband frequency of t he DART – Diversity—whet her DART is configured as Diversity or Non Diversity. For t his release, t his will always be Non Diversity. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 105 © 2011 ADC Telecom m unicat ions, I nc. Get I nform at ion Viewing the Delay Report To access t he Linked DARTs Delay report , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Delay. The Linked DARTs Delay t able provides t he following inform at ion: • Host colum ns—ident ifies t he Host in t he link – DART Id—num ber of t he Host slot in which t he DART is inst alled – DART Name—user- defined nam e for t he Host DART. • Remote colum ns—ident ifies t he Rem ot e and it s elem ent s – Id—Unit I D of PRU/ URU based upon layered address; see “ Unit I dent ificat ion” on page 43 – Name—user- defined label for t he PRU/ URU – DART Id—PRU/ URU slot num ber in which t he DART is inst alled – DART Name—user- defined nam e for t he Rem ot e DART – Forward Delay ( s) —user request ed FWD RF pat h delay in m icroseconds – Reverse Delay ( s) —user request ed REV RF pat h delay in m icroseconds. • Common colum ns—ident ify configurat ion set t ings t hat are com m on t o t he Host and connect ed Rem ot e( s) – Passband—t ype of passband provided by t he DART – Frequency (MHz)—passband frequency of t he DART. Page 106 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion Viewing the Fiber Report To access t he Fiber Optics report , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Fiber. The Fiber Optics t able provides t he following inform at ion: • Unit Type—what t he unit is, such as Host or Rem ot e. • Unit Name—Unit I D of t he unit based upon layered address; see “ Unit I dent ificat ion” on page 43. • SFP Number—Opt ical port num ber, from 1 t o 8. • SFP Name—nam e assigned UNKNOWN_SFPNAME. • Optics Type – LongRange—26 dB – IntermediateRange—18 dB) . • Wavelength (nm)—wave lengt h t ransm it t ed t hrough t his port : – Non- duplex and WDM configurat ions: 1550 nm fwd, 1310 nm rev – CWDM configurat ions can be one of eight wavelengt hs: 1470 nm , 1490 nm , 1510 nm , 1530 nm , 1550 nm , 1570 nm , 1590 nm , and 1610 nm . • Tx Power (dBm)—launch power level in dBm of forward pat h signal. The m inim um FWD launch power is - 2 dBm , and t he m axim um is 3 dBm . • Rx Power (dBm)—receive power level in dBm of reverse pat h signal, which incorporat es t he launch power of t he Rem ot e Unit SFP plus all opt ical losses ( insert ion losses, fiber cable loss, and so fort h) . • Remote Name—nam e of t he Rem ot e connect ed t o t his Opt ical port . • Alarm Status—whet her an alarm is act ive. I f an alarm is act ive, t here will be a Minor or Major link t hat you click t o open a dialog t hat defines t he act ive alarm , as described in “ Viewing Alarm Det ails” on page 45. The background color of t he Alarm Status cell also indicat es t he alarm level ( see “ Alarm Color Codes” on page 44) . to t he FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Opt ical port ; default SFP Name is Page 107 © 2011 ADC Telecom m unicat ions, I nc. Get I nform at ion Viewing the Host RF Report To access t he Host Forward Gain Settings report , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Host RF. The Host Forward Gain Settings t able provides t he following inform at ion. • DART Id—num ber of t he Host slot in which t he DART is inst alled • DART Name—user- defined nam e for t he Host DART • DART Mode—ident ifies t he RF funct ion – Standby—RF funct ion is m ut ed in t he Host and it s linked Rem ot e Unit . – Normal—RF funct ion not forced t o be m ut ed, allows t he syst em t o operat e norm ally • Fwd Gain (db)—Forward Gain in decibels assigned t o t he DART • Power Level Mode—Host DART I nput Power Level Mode: – Snapshot—provides a “ snap- shot ” or current RF m easurem ent for t he select ed Rem ot e DART ( default set t ing) . – Max Hold—ret ains t he m axim um values for peak and peak average, and t he m inim um values for m inim um average since t he last Max Hold Reset. NOTE: The Power Level Mode is disabled if the: • DART Operating mode is set to Standby • DART Pass Band (Timeslots) parameter is set to Undefined (default) • DART Diversity Status is set to Diversity. • Peak Power (dBm)—highest level of power experienced on t he DART Forward link. • Average Power (dBm)—average power experienced on t he DART Forward link. • Minimum Power (dBm)—average m inim um power experienced on t he DART Forward link. • Last Max Hold Reset Time—t im e t hat Max Hold was last reset . • Passband—t ype of passband provided by t he DART. • Frequency (MHz)—passband frequency of t he DART Page 108 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion Viewing the Remote RF Report To access t he Remote Forward Gain Settings report , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Remote RF. The Remote Forward Gain Settings t able provides t he following inform at ion: • Host colum ns—ident ifies t he Host in t he link – DART Id—num ber assigned by t he EMS t o t he Host DART for ident ificat ion purposes – DART Name—user- defined nam e for t he DART. • Remote colum ns—ident ifies t he Rem ot e and it s elem ent s – DART Id—Unit I D of PRU/ URU based upon layered address; see “ Unit I dent ificat ion” on page 43 – DART Name—user- defined label for t he PRU/ URU – DART Mode—how RF funct ions on t hat DART • Standby—forces t he RF funct ion t o be m ut ed in t he Host and it s linked Rem ot e. Normal—allows t he syst em t o operat e norm ally ( RF funct ion not forced t o be m ut ed) , assum ing all ot her syst em com ponent s are in proper working order. ( Default set t ing.) Forward Gain (db)—act ual gain, not at t enuat ion, applied t o t he RF forward pat h signal ( where 0 = 0 dB gain, 1 = 1 dB gain, and so fort h) RF Power (dBm)—est im at ed power level based upon input level and gain. Max Power (dBm)—t he m axim um LPA power values VSWR—t he Volt age St anding Wave Rat io ( VSWR) for t he LPA. An LPA VSWR Fault occurs if t he VSWR m easurem ent exceeds t he t hreshold, which is 3: 1. LPA Mode—t he LPA Mode, which can be Normal or Standby LPA Status—t he LPA st at us. I n case of dual LPA, it will indicat e t he value for bot h LPAs as eit her 1-Offline or 2-Operating. • – – – – – – • Passband—t ype of passband provided by t he DART • Frequency (MHz)—passband frequency of t he DART FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 109 © 2011 ADC Telecom m unicat ions, I nc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : TE106558 Create Date : 2011:12:06 13:34:28-08:00 Modify Date : 2011:12:06 13:37:12-08:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2011:12:06 13:37:12-08:00 Creator Tool : FrameMaker 7.1 Format : application/pdf Title : ADC FlexWave Prism Element Management System 7.1 User Manual Creator : TE106558 Document ID : uuid:c5a66eaa-6632-46e6-8f7a-0a43299fc342 Instance ID : uuid:95ad8d69-bb4c-40bc-8439-325f6167349a Producer : Acrobat Distiller 9.4.5 (Windows) Page Count : 65EXIF Metadata provided by EXIF.tools