ADC Telecommunications PSM0804A FlexWave™ Prism - Cellular 40 Watt User Manual 3
ADC Telecommunications Inc FlexWave Prism - Cellular 40 Watt Users Manual 3
Contents
- 1. Users Manual 1
- 2. Users Manual 2
- 3. Users Manual 3
- 4. Users Manual 4
Users Manual 3
Get I nform at ion Viewing the Alarms Report To access t he Current Alarms report , in t he Syst em Menu bar, click System Information > Get Information, and t hen in t he Reports panel Type list , select Alarms. The Current Alarms t able provides t he following inform at ion: • Severity—whet her alarm is classified as Maj or or Minor. • Ack’d—whet her checkm ark. • Alarm Code—syst em - assigned alarm code. See “ Troubleshoot ing Alarm s” on page 185 or use t he “ I ndex of Alarm s” on page 313 t o find t he page num ber for a specific alarm descript ion, which includes t he alarm code. • Alarm Name—descript ive nam e of alarm . • Timestamp—dat e and t im e when t he alarm occurred ( YYYY:MM:DD:HH:MM:SS) • Unit Id—ident ifies t he unit wit hin t he syst em ; see “ Unit I dent ificat ion” on page 43. • Unit Type—what t he unit is, such as Host or Rem ot e • Unit Name—nam e assigned t o t he unit • Module—t ype of m odule wit hin t he specified unit t hat is experiencing t he alarm ( SeRF, DART, Power Det ect or, SFP) • Module Name—user- assigned nam e for t he m odule t hat assist s in ident ifying m odules when t roubleshoot ing • RF Band—t ype of passband provided by t he DART ( if applicable) Page 110 © 2011 ADC Telecommunications, Inc t he alarm has been acknowledged, as indicat ed by FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion • Extended Info—link t hat provides furt her inform at ion on t he alarm , including t roubleshoot ing inform at ion. IFEU + RAU Report The IFEU + RAU report pert ains t o an I nt erReach Spect rum syst em and is not applicable t o t his release. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 111 © 2011 ADC Telecom m unicat ions, I nc. Get I nform at ion Viewing the All Report The All Report consolidat es all available report s int o a single web page. Page 112 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion Downloading a Report CAUTION! The All Report or Analog Units Report can take several minutes to download. You can download t he report s t o your lapt op in Windows Excel form at . Do t he following t o download a report t o your com put er: I n t he Syst em Menu bar, click System Information > Get Information. On t he Get Information page, in t he Reports panel Type list , select t he nam e of t he report t hat you want t o download. Click Download. I n t he File Download window, click Save. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 113 © 2011 ADC Telecom m unicat ions, I nc. Get I nform at ion I n t he Save As window, navigat e t o where you want t he report file saved, and t hen click Save. The file is saved as specified. Page 114 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion Go t o t he direct ory where t he file was saved t o open t he file. NOTE: While Excel is often used to view this file, Excel uses characters such as hyphens and slashes to create formulas. If discrepancies are seen in this report, use a text editor to verify the report’s content. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 115 © 2011 ADC Telecom m unicat ions, I nc. Get Opt ics I nform at ion GET OPTICS INFORMATION The Get Optics Information page allows you t o view inform at ion on t he fiber. To access t he Get Optics Information page, in t he Syst em Menu bar, click System Information > Get Optics Information. The Filter panel has t he following elem ent s: • View list —allows you t o select a filt er t o be applied t o t he page • contains box—allows you t o ent er filt er crit eria • Filter but t on—click t o apply t he filt er The Get Optics Information t able has t he following elem ent s: • Unit Type—whet her t he unit is a Host or Rem ot e • Unit Name—user defined nam e of t he unit • SFP Number—syst em assigned num ber ( from 1 t o 8) for t he Opt ical port s • SFP Name—user ent ered port nam e or UNKNOWN_SFPNAME, which indicat es t hat a nam e has not been ent ered. • Optics Type – LongRange—26 dB – IntermediateRange—18 dB) . Page 116 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion • Wavelength (nm)—num ber displayed is t he wavelengt h t ransm it t ed t hrough t his port : – Non- duplex and WDM configurat ions 1550 nm fwd 1310 nm rev – CWDM configurat ions can be one of eight wavelengt hs: 1470 nm 1550 nm 1490 nm 1570 nm 1510 nm 1590 nm 1530 nm 1610 nm • Tx Power (dBm)—launch power level in dBm of forward pat h signal. The m inim um FWD launch power is - 2 dBm , and t he m axim um is 3 dBm . • Rx Power (dBm)—Receive power level in dBm of reverse pat h signal, which incorporat es t he launch power of t he Rem ot e Unit SFP plus all opt ical losses ( insert ion losses, fiber cable loss, and so fort h) . • Remote Name—nam e of t he Rem ot e connect ed t o t his Opt ics port . • Alarm Status—whet her an alarm is act ive. I f an alarm is act ive, t here will be a Minor or Major link t hat you click t o open a dialog t hat defines t he act ive alarm , as described in “ Viewing Alarm Det ails” on page 45. The background color of t he Alarm Status cell also indicat es t he alarm level ( see “ Alarm Color Codes” on page 44) . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 117 © 2011 ADC Telecom m unicat ions, I nc. Get Logs G ET L OGS The Get Logs page allows you t o save com pressed t ar archive files of Prism logs.This feat ure is prim arily used by ADC personnel when t roubleshoot ing a syst em . However, you should know how t o creat e a log so you can em ail t he log t o ADC if request ed t o do so. To access t he Get Logs page, in t he Syst em Menu bar, click System Information > Get Logs. Click Get Logs. I n t he File Download dialog, click Save. Page 118 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em I nform at ion I n t he Save As dialog, navigat e t o where you want t o save t he log file. Aft er a log has been creat ed, it is list ed as an Available Log in t he Get Logs page. I n Windows, navigat e t o where you saved t he log zip file on your hard drive. Double- click on t he t ar file t o access t he logs. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 119 © 2011 ADC Telecom m unicat ions, I nc. Get Logs I nt ent ionally Blank Page Page 120 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 SYSTEM MANAGEMENT Topics Page Moving or Reconfiguring Fibers .............................................................................................. 122 Edit t he Propert ies of All Unit s in t he Syst em ........................................................................... 123 Reset All Unit s t o Fact ory Default ........................................................................................... 124 Backing Up a Syst em Configurat ion ........................................................................................ 126 Rest oring a Backed Up Syst em Configurat ion ........................................................................... 128 Perform Syst em Test ............................................................................................................ 131 Schedule Syst em Test .......................................................................................................... 135 Schedule Syst em Test s by Dat e and Tim e .......................................................................... 135 Disable a Scheduled Syst em Test ...................................................................................... 137 Set SNMP Trap Managers ...................................................................................................... 138 Adding an SNMP Trap Manager ......................................................................................... 139 Modifying an SNMP Trap Manager ..................................................................................... 141 Delet ing an SNMP Trap Manager ....................................................................................... 142 Set up SNMP ....................................................................................................................... 144 Act ivat e Opt ional Feat ures .................................................................................................... 145 The EMS views and param et ers discussed in t his sect ion affect t he ent ire Prism syst em , as opposed t o affect ing an individual unit or m odule. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 121 © 2011 ADC Telecommunications, Inc. Moving or Reconfiguring Fibers MOVING OR RECONFIGURING FIBERS I f you need t o m ove or reconfigure fibers during t roubleshoot ing, follow t he st eps below. Move Host SFPs and fibers t o t heir new locat ions. Do t he following if a previously filled SFP posit ion is now em pt y: There will st ill be a GUI represent at ion of a Rem ot e on t hat SFP. To rem ove t his ghost represent at ion, follow t he st eps in “ Clear All Disconnect Alarm s” on page 184. To delet e fiber and SFP alarm s at t ribut ed t o t he abandoned SFP posit ions, follow t he st eps in “ Clear Current Alarm s” on page 170. Com ple t e t h is st e p on ly for m ove d D ARTs n ow in a n a la r m e d st a t e . I f t he configurat ion of a Rem ot e Unit DART originally connect ed t o an SFP does not m at ch t he configurat ion of t he DART m oved t o t he SFP, t he new DART will have an alarm st at e such as Module Missing Fault or DART Hardware Mismatch. I n t his inst ance, follow t he st eps in “ Clearing DART Configurat ions” on page 161 t o clear t he configurat ion of t he DART in t he alarm ed st at e. Page 122 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent E DIT THE P ROPERTIES OF A LL U NITS IN THE S YSTEM The Edit Unit Properties page t hat is accessible t hrough t he Syst em Menu bar allows you t o edit basic inform at ion and opt ionally provide not es for all t he unit s in t he syst em at one t im e. To access t he Edit Unit Properties page, in t he Syst em Menu bar, click System Configuration > Edit Unit Properties. The Edit Unit Properties page has t he following elem ent s, where each row in t he Edit Unit Properties t able correspond t o t he unit ident ified in t he Unit Id colum n. • Unit Id colum n—ident ifies t he unit wit hin t he syst em ; see “ Unit I dent ificat ion” on page 43. • Unit Name colum n—provides a t ext box t hat allows you t o ent er a unique nam e for t he Host and each connect ed Rem ot e. Each Unit Name m ust st art wit h an alphabet ical charact er, be bet ween 5 and 40 charact ers ( alphanum eric or underscore only) , and cont ain no spaces. • IP Address colum n—t he I P address of t he unit NOTE: • Contact Alarms colum n—ident ifies act ive cont act alarm s, if any. For inform at ion on cont act alarm s, see any of t he following: – “ Cont act Alarm s—Host Syst em Card” on page 201 – • An IP address of the type 169.254.x.y will only be communicable if the connected laptop also has a 169.254.x.y address. “ Cont act Alarm s—Rem ot e Unit ” on page 201 Notes colum n—provides a t ext box t hat allows you t o ent er not es specific t o t he unit . You can ent er up t o 256 charact ers; all keyboard charact ers can be used. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 123 © 2011 ADC Telecom m unicat ions, I nc. Reset All Unit s t o Fact ory Default R ESET A LL U NITS TO F ACTORY D EFAULT This procedure reset s t he Host and all connect ed Rem ot e Unit s ( PRU or URU) t o t heir fact ory default set t ings. This procedure does not clear com m anded Out of Service and Band Lockout set t ings ( see Table on page 42) . Docum ent all configurat ion dat a, as everyt hing except user I Ds and I P configurat ion will have t o be re- ent ered. To record t he current configurat ion: Follow t he procedures in “ Viewing t he All Report ” on page 112 t o access t he syst em configurat ion report s. Follow t he procedures in “ Downloading a Report ” on page 113 t o download t he syst em configurat ion report s t o a hard drive. I n t he Syst em Tree, click on t he Host icon. I n t he Unit Menu bar, click Unit Configuration > Edit Properties, t o open t he Unit Configuration > Edit Properties page. Click Reset all units to factory defaults. I n t he confirm at ion dialog, click OK. The syst em configurat ion is cleared, and you are logged out of your current EMS session. Page 124 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent Log back int o t he EMS t o reconfigure t he syst em . NOTE: It may take a few minutes for the EMS to recognize the Host and connected remotes. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 125 © 2011 ADC Telecom m unicat ions, I nc. Backing Up a Syst em Configurat ion B ACKING U P A S YSTEM C ONFIGURATION The Backup page allows you t o backup t he syst em configurat ion. A backup file size is t ypically less t han 1 MB, and a new backup overwrit es t he pre- exist ing backup. You use t he backup file t o rest ore t he configurat ion as described in “ Rest oring a Backed Up Syst em Configurat ion” on page 128. Do t he following t o backup a syst em configurat ion: I n t he Syst em Menu bar, click System Configuration > Backup. Click Backup. I f t he back up procedure fails, t he following error m essage displays: Failed to create Back Up. At t he end of a successful backup, a link t o t he downloaded file appears. To download t he back- up file, click t he link t hat appears, t he nam e for which is in t he form at of HOSTNAME_.tgz. Only one file will be available. Page 126 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent I n t he File Download window, click Save. I n t he Save As window, navigat e t o where you want t he backup file saved, and t hen click Save. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 127 © 2011 ADC Telecom m unicat ions, I nc. Rest oring a Backed Up Syst em Configurat ion R ESTORING A B ACKED U P S YSTEM C ONFIGURATION CAUTION! A System Restore can only occur if a previous system configuration has been backed up as described in “Backing Up a System Configuration” on page 126. CAUTION! A system restore requires that you log back into the system. Once you click the Restore button, the system will be unavailable for approximately two minutes. Perform this procedure during a maintenance window. NOTE: A System Restore can only be performed by a user logged in as admin user or by a user with Network Manager rights. A user assigned only Network User rights will not see the System Restore node in the Function System Tree. The System Restore page allows for a rest orat ion of a backed up syst em configurat ion, as follows: • The Rest ore funct ion assum es t hat t he sam e or com parable replacem ent hardware com ponent s are in place as when t he Backup funct ion occurred. I f hardware com ponent changes have occurred, alarm s t hat point t o t he differences will arise. • I f a Rem ot e has been added ( t hat is, was not part of t he original syst em hardware set up) , t hen t he newly added Rem ot e will not be rest ored since it was not present during t he syst em configurat ion backup. D o t he follow in g t o r e st or e a syst e m ba ck up: Make sure t here is sufficient disk space for t he backed up syst em configurat ion t hat you want t o rest ore. I n t he Syst em Menu bar, click System Configuration > Restore. Click t he Browse but t on next t o t he File box t o browse t o t he locat ion of t he backup file. Page 128 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent I n t he Choose File window, click on t he back- up file t o select it ( t he backup filenam e is in t he form at of HOSTNAME_ .tgz, and t hen click Open. I n t he Restore page, wait for t he file nam e and pat h t o display in t he File box and for t he ennoblem ent of t he Upload but t on, and t hen click Upload. I n t he Restore page, wait for t he file upload m essage t o display and for t he ennoblem ent of t he Upload and Restore but t ons, and t hen click Restore. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 129 © 2011 ADC Telecom m unicat ions, I nc. Rest oring a Backed Up Syst em Configurat ion I n t he confirm at ion dialog, click OK. St at us m essages display t o not ify you if t he rest orat ion failed or com plet ed successfully. Aft er a successful rest orat ion, you are logged out of t he syst em . Log back in t o t he EMS t o cont inue m anagem ent act ivit ies. Page 130 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent PERFORM SYSTEM TEST Syst em Test perform s an RF int egrit y check of t he syst em . Cert ain alarm s ( such as t he RAU Antenna Disconnect alarm ) can only be set or cleared by running Syst em Test . CAUTION! Running System Test (System Configuration > Perform System Test) with un-terminated Host DARTs may cause a false RLM Upconvert Fault. Ensure that all Host DARTs are terminated before running System Test. CAUTION! System Test interrupts RF transmission; System Test should therefore only be run during a normal maintenance window. CAUTION! Do not make any software or hardware configuration changes during System Test, as changes made during the test will make the test results unreliable. I n t he Syst em Menu bar, click System Configuration > Perform System Test. NOTE: The table at the bottom of the Perform System Test page presents the results of the last System Test, if any, as shown above. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 131 © 2011 ADC Telecom m unicat ions, I nc. Perform Syst em Test I n t he Bands list , select t he passbands for which you want t o perform Syst em Test . Only configured passbands will be list ed in t he Bands list . I n t he DART list , select t he DART you want t o perform Syst em Test . Only t hose DARTS t hat are available will be list ed in t he DART list . CAUTION! Regardless if only 1 DART or all DARTs are selected for System Test, System Test temporarily shuts down the RF to all DARTs in the system. Page 132 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent Click Perform System Test. A System Test has started m essage displays. This m essage should be followed by one of t hese m essages. You m ay need t o click Refresh t o see t hese m essages. • System Test passed. • System Test failed. • System Test not available. • System Test passed – exceptions noted in log file. Aft er a few seconds, t he Last Test Results panel updat es wit h a list of m aj or and m inor alarm s wit h a corresponding t im est am p for when Syst em Test was run. ( Opt ional) Do t he following t o download t he result s of Syst em Test ( t o m ake t he file available for lat er use, such as t roubleshoot ing) . Click t he Click Here to Download link. I n t he File Download dialog, click Save. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 133 © 2011 ADC Telecom m unicat ions, I nc. Perform Syst em Test I n t he Save As dialog, navigat e t o where you want t o save t he file, and t hen click Save. The file is saved in Excel form at . Page 134 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent SCHEDULE SYSTEM TEST You can schedule a Syst em Test t o run on a specific dat e and t im e, as described in: • “ Schedule Syst em Test s by Dat e and Tim e” on page 135 • “ Disable a Scheduled Syst em Test ” on page 137 Schedule System Tests by Date and Time CAUTION! Running System Test (System Configuration > Perform System Test) with un-terminated Host DARTs may cause a false RLM Upconvert Fault. Ensure that all Host DARTs are terminated before running System Test. CAUTION! System Test interrupts RF transmission; System Test should therefore only be run during a normal maintenance window. CAUTION! Do not make any software or hardware configuration changes during System Test, as changes made during the test will make the test results unreliable. Do t he following t o schedule a single or recurring Syst em Test : I n t he Syst em Menu bar, click System Configuration > Schedule System Test. Select Enable t o enable t he scheduled Syst em Test ( see also “ Disable a Scheduled Syst em Test ” on page 137) . I n t he Bands list , select t he band( s) t hat you want t o t est . I n t he DART list , select t he DART( s) t hat you want t o t est . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 135 © 2011 ADC Telecom m unicat ions, I nc. Schedule Syst em Test Click t he icon t o t he right of t he DATE box t o schedule on which dat e t he Syst em Test will run. I f you ent er t he dat e m anually, use t he YYYY/MM/DD form at . For exam ple, t o run a Syst em Test on 14 June 2011, ent er: 2011/06/14. I n t he Time box, ent er t he t im e t hat t he Syst em Test is t o run. Use t he 24- hour t im eclock form at of HH:MM:SS. ( Opt ional) Use t he Recurrence radio but t ons t o set up a recurring Syst em Test . • To have t he Syst em Test recurrence int erval be count ed by days, select t he Day(s) (1-30) radio but t on, and t hen in t he corresponding box, ent er how m any days should pass bet ween each occurrence of t his Syst em Test . • To have t he Syst em Test recurrence int erval be count ed by weeks, select t he Week(s) (1-4) radio but t on, and t hen in t he corresponding box, ent er how m any weeks should pass bet ween each occurrence of t his Syst em Test . Click Apply. NOTE: If you leave either the DATE or TIME parameter empty and then click Apply, Schedule System Test will not run. However, if you leave both the DATE and TIME parameters empty and then click Apply, the System Test starts immediately. The following exam ple has scheduled a Syst em Test for 850 Classic passbands on 850 Classic DARTs inst alled in Host 1 t o occur on 2 April 2011 at 1: 00 AM. This Syst em Test will occur in one- week int ervals. Page 136 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent Disable a Scheduled System Test When you disable a scheduled Syst em Test , t he Bands, DART, Date, and Time set t ing rem ain, but t he t est will not be run again unt il enabled. I n t he Syst em Menu bar, click System Configuration > Schedule System Test. Deselect Enable. Click Apply. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 137 © 2011 ADC Telecom m unicat ions, I nc. Set SNMP Trap Managers SET SNMP TRAP MANAGERS The Set SNMP Trap Managers page allows you t o add, delet e, and m odify SNMP Trap Managers. The Registered Trap Manager t able, at t he t op of t he page, det ails any exist ing SNMP Trap Managers, where: • Select radio but t on—allows you t o select an exist ing SNMP Trap Manager t o m odify or delet e it . • IP Address—shows t he I P address of regist ered t rap m anagers • Port—shows t he port num ber for regist ered t rap m anagers • Community—shows t he Com m unit y password for regist ered t rap m anagers • Version—shows t he t rap version for regist ered t rap m anagers I f a Trap Manager has not been creat ed, t he t able is em pt y: Page 138 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent Adding an SNMP Trap Manager I n t he Syst em Menu bar, click System Configuration > Set SNMP Trap Managers. I n t he Add New Trap Manager panel, do t he following: I n t he IP Address box ent er t he I P address of t he device t hat you want t o add as a t rap receiver. The address m ust be in t he xxx.xxx.xxx.xxx form at . I n t he Port box, ent er t he port on t he device t hat will receive t he t raps. The norm al and recom m ended SNMP Trap port is 162. I n t he Community box, ent er a password t hat will allow access t o t he device. The Community password m ust be bet ween 6 and 20 alphanum eric charact ers ( usually public or private) . I n t he Version list , select t he t rap version for t he SNMP Trap Manager t hat you are regist ering ( V1 or V2c) . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 139 © 2011 ADC Telecom m unicat ions, I nc. Set SNMP Trap Managers Click Add. The Registered Trap Managers t able updat es wit h t he new SNMP Trap Manager. Page 140 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent Modifying an SNMP Trap Manager I n t he Syst em Menu bar, click System Configuration > Set SNMP Trap Managers. The Registered Trap Managers t able list s exist ing SNMP Trap Managers. I n t he Registered Trap Managers t able, select t he t rap m anager t hat you want t o m odify. I n t he Add New Trap Manager panel, do any of t he following: • I n t he IP Address box ent er a new I P address. The address m ust be in t he xxx.xxx.xxx.xxx form at . • I n t he Port box, ent er t he port on t he device t hat will receive t he t raps. The norm al and recom m ended SNMP t rap port is 162. • I n t he Community box, ent er a password t hat allows access to t he device ( usually public or privat e) . The Com m unit y password is lim it ed t o 20 charact ers. • I n t he Version list , select t he t rap version for t he SNMP Trap Manager t hat you are regist ering. Click Modify. The Registered Trap Managers t able updat es wit h t he m odified SNMP Trap Manager. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 141 © 2011 ADC Telecom m unicat ions, I nc. Set SNMP Trap Managers Deleting an SNMP Trap Manager I n t he Syst em Menu bar, click System Configuration > Set SNMP Trap Managers. The Registered Trap Managers t able list s exist ing SNMP Trap Managers. I n t he Registered Trap Managers t able, select t he t rap m anager t hat you want t o delet e. Click Delete. I n t he confirm at ion window, click OK. Page 142 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent The delet ed SNMP Trap Manager is rem oved from t he Registered Trap Managers t able and will no longer receive t raps. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 143 © 2011 ADC Telecom m unicat ions, I nc. Set up SNMP SETUP SNMP To access t he Setup SNMP page, in t he Syst em Menu bar, click System Configuration > Setup SNMP. I n t he SNMP V1 Agent Override panel, do t he following. I n t he Mode list , select t he SNMP V1 Agent Override m ode: • Enabled • Disabled I n t he Address box, ent er t he SNMP V1 Agent Override address. I f t he SNMP Agent Override Mode is not Disabled, t he syst em uses t his address as t he source address in t he t raps. I n t he SNMP Port Number box, ent er t he SNMP port num ber for sets and gets. Click Apply t o m odify t he SNMP set t ings. Page 144 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Syst em Managem ent A CTIVATE O PTIONAL F EATURES The Activate Optional Features page allows you t o act ivat e opt ional feat ures available in t he syst em t hat are purchased aft er t he Host Unit has been shipped. NOTE: Activation Codes are supplied by ADC Technical Assistance (see “Appendix C: Contacting ADC/TE Connectivity” on page 297). To access t he Activate Optional Features page, in t he Syst em Menu bar, click System Configuration > Activate Optional Features. I n t he Activation Code box t hat corresponds t o t he feat ure t hat you want t o act ivat e, ent er t he act ivat ion code provided by ADC. Click Activate. The following Information m essage displays. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 145 © 2011 ADC Telecom m unicat ions, I nc. Act ivat e Opt ional Feat ures I nt ent ionally Blank Page Page 146 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 MANAGING UNITS Topics Page Basic Unit Views .................................................................................................................. 148 View Opt ical Port s ................................................................................................................ 149 Viewing DARTs .................................................................................................................... 151 Viewing Net work St at ist ics .................................................................................................... 152 Edit ing Unit Propert ies .......................................................................................................... 153 Configuring Opt ical Port s....................................................................................................... 153 Viewing t he St at us of t he Host Unit ........................................................................................ 154 Viewing t he St at us of a Rem ot e Unit ....................................................................................... 156 Module St at us Table ....................................................................................................... 156 DART St at us Table .................................................................................................... 157 LNA St at us Table ...................................................................................................... 158 LPA St at us Table....................................................................................................... 158 PD St at us Table ........................................................................................................ 159 Opt ical St at us Table ........................................................................................................ 159 Rem ot e St at us Table....................................................................................................... 160 Rem ot e Unit Capacit y and Tem perat ure ............................................................................. 160 Clearing DART Configurat ions ................................................................................................ 161 Set t he Capacit y for a New Rem ot e Unit RSI Board ................................................................... 162 Using t he EMS GUI t o Change t he Rem ot e Unit Capacit y ...................................................... 162 Using Telnet or ssh t o Change t he Rem ot e Unit Capacit y ...................................................... 163 Reboot ing a Unit .................................................................................................................. 164 Reset t ing an LPA.................................................................................................................. 165 This sect ion describes t he Prism EMS param et ers whose set t ings affect t he individual unit s wit hin a Prism syst em . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 147 © 2011 ADC Telecommunications, Inc. Basic Unit Views BASIC UNIT VIEWS When you click on a device icon in t he Syst em Tree, t he following view opens in t he EMS View Fram e, in which t here are t hree places where t he select ed device is ident ified. Not ice also t he indicat ors for act ive alarm s. I n t his inst ance t he alarm overlays on t he Host and Rem ot e Unit icons indicat e t hat an alarm is act ive on each device, and t he Alarm Count er shows t he count of act ive alarm s. The following graphic ident ifies t he com ponent s in a basic unit view. Unit identifiers in System Tree (by Unit Name and Unit ID) Alarm Counter (system wide) Unit identifier (by Unit Name) Host icon with Minor alarm overlay Remote Unit icon with Major alarm overlay Unit identifier (by Unit Name) Figure 22. Overview of Components in a Basic Unit View The Unit view provides t he following inform at ion: • Name—user- defined or syst em nam e of t he select ed unit . • Unit Type—t he t ype of device t hat t he select ed unit is: – Host – PRU—Prism Rem ot e Unit – URU—URH Rem ot e Unit • Alarm—highest level of alarm occurring on t he select ed unit . Not ice t hat in t his exam ple, t he Alarm indicat ors show t hat t here are four Minor alarm s act ive on t his syst em . The Unit view let s you know t hat at least one of t he alarm s is act ive on t he Host . • Temperature—int ernal t em perat ure of t he select ed unit . • Notes—t ext box t hat allows you t o ent er not es specific t o t he select ed unit . You can ent er up t o 256 charact ers; all keyboard charact ers can be used. Page 148 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s VIEW OPTICAL PORTS The View Optical Ports page shows t he current usage and alarm st at us of t he opt ical port s on a Host or a PRU/ URU plus t he current values of key operat ing param et ers. The Host and PRU/ URU chassis have eight opt ical port s, but t he View Optical Ports page only shows act ive port s ( t hose physically connect ed t o a Host or PRU/ URU) . Each port in t he page represent s one set of forward and reverse pat hs bet ween a Host and Rem ot e. I n t he Syst em Tree, click on an icon for a Host or Rem ot e Unit . I n t he Unit Menu bar, click Unit Information > View Optical Ports. The View Optical Ports t able has t he following com ponent s: • SFP Number—Syst em assigned port num ber. • SFP Name—user ent ered port nam e or UNKNOWN_SFPNAME, which indicat es t hat no nam e has been ent ered. • In/Out—used for cascading, which is not support ed in t his release. The Host will t herefore always be set as Out ( indicat es t hat t he forward link for t he connect ed SFP is going away from t he Host ) and t he SFPs for all Rem ot e Unit s will always be set as In. • Optics Type – LongRange—26 dB – IntermediateRange—18 dB. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 149 © 2011 ADC Telecom m unicat ions, I nc. View Opt ical Port s • Wavelength (nm)—wave lengt h t ransm it t ed t hrough t his port : – Non- duplex and WDM configurat ions: 1550 nm fwd or 1310 nm rev – CWDM configurat ions can be one of eight wavelengt hs: 1470 nm 1510 nm 1550 nm 1590 nm 1490 nm 1530 nm 1570 nm 1610 nm • Tx Power (dBm)—launch power level in dBm of forward pat h signal. The m inim um FWD launch power is - 2 dBm , and t he m axim um is 3 dBm . • Rx Power (dBm)—receive power level in dBm of reverse pat h signal, which incorporat es t he launch power of t he Rem ot e Unit SFP plus all opt ical losses ( insert ion losses, fiber cable loss, and so fort h) . • Host Name/Remote Name—dependent on t he unit select ed in St ep 1 on page 149: – I f a Host Unit was select ed, t hen t he colum n is labeled Remote Name and t he dat a in t he colum n pert ains t o t he Rem ot e connect ed t o t his Opt ical port ident ified in SFP Number and SFP Name. – I f a Rem ot e Unit was select ed, t hen t he colum n is labeled Host Name and t he dat a in t he colum n pert ains t o t he Host ( for select ed PRU/ URU) connect ed t o t his Opt ical port ident ified in SFP Number and SFP Name. • Alarm Status—whet her an alarm is act ive. I f an alarm is act ive, t here will be a Minor or Major link t hat you click t o open a dialog t hat defines t he act ive alarm , as described in “ Viewing Alarm Det ails” on page 45. The background color of t he Alarm Status cell also indicat es t he alarm level ( see “ Alarm Color Codes” on page 44) . Page 150 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s VIEWING DARTS I n t he Syst em Tree, click on t he icon of t he Host or PRU/ URU for which you want t o view inform at ion on it s DARTs. I n t he Unit Menu bar, click Unit Information > View DARTs t o open t he View DARTs page. The t able in t he View DARTs page provides t he following inform at ion: • DART Number—ident ifies any inst alled DARTs by t he slot num ber in which it is inst alled in t he Host or PRU/ URU chassis • DART Name—syst em or user- assigned nam e; default is UNKNOWN_DARTNAME. • Band Type—which DART m odel is inst alled, and t he band t ype t hat it is providing • Passband—t ype of passband • Alarm Status—whet her an alarm is act ive. I f an alarm is act ive, t here will be a Minor or Major link t hat you click t o open a dialog t hat defines t he act ive alarm , as described in “ Viewing Alarm Det ails” on page 45. The background color of t he Alarm Status cell also indicat es t he alarm level ( see “ Alarm Color Codes” on page 44) . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 151 © 2011 ADC Telecom m unicat ions, I nc. Viewing Net work St at ist ics VIEWING NETWORK STATISTICS I n t he Syst em Tree, click on an icon for a Host or Rem ot e Unit . I n t he Unit Menu bar, click Unit Information > View Network Statistics t o open t he View Network Statistics page. The View Network Statistics t able has t he following com ponent s: • Port—I dent ifies t he port s in t he net work. • Rx Bytes—Receive byt e count er t hat increm ent s by t he byt e count of fram es received, including t hose in bad packet s, excluding pream ble and SFD but including FCS byt es. • Rx Packets—Receive packet count er t hat increm ent s for each fram e received packet ( including bad packet s, all unicast , broadcast , and m ult icast packet s) . • RX FCS Errors—Receive FCS error count er t hat increm ent s for each fram e received t hat has an int egral 64 t o 1518 lengt h and cont ains a fram e check sequence error. • Rx Broadcast Pkts—Receive broadcast packet count er t hat increm ent s for each broadcast good fram e of lengt hs 64 t o 1518 ( non VLAN) or 1522 ( VLAN) , excluding m ult icast fram es. Does not include range/ lengt h errors. • Rx Multicast Pkts—Receive m ult icast packet count er t hat increm ent s for each m ult icast good fram e of lengt hs 64 t o 1518 ( non VLAN) or 1522 ( VLAN) , excluding broadcast fram es. This count does not include range/ lengt h errors. • Rx Fragmented Frames—Receive fragm ent s count er t hat increm ent s for each fram e received t hat cont ains an invalid FCS and is less t han 64 byt es. This includes int egral and non- int egral lengt hs. • Rx Jabber Frames—Receive j abber count er t hat increm ent s for fram es received t hat exceed 1518 ( non VLAN) or 1522 ( VLAN) byt es and cont ain an invalid FCS. This includes alignm ent errors. Page 152 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s • Tx Byte Counter—Transm it byt e count er t hat increm ent s by t he num ber of byt es t hat were put on t he wire including fragm ent s of fram es t hat were involved wit h collisions. This count does not include pream ble/ SFD or j am byt es. This count er does not count if t he fram e is t runcat ed. • Tx Pkt Counter—Transm it packet count er t hat increm ent s for each t ransm it t ed packet ( including bad packet s, excessive deferred packet s, excessive collision packet s, lat e collision packet s, all unicast , broadcast , and m ult icast packet s) . • Tx Broadcast Pkts—Transm it broadcast packet count er t hat increm ent s for each broadcast fram e t ransm it t ed ( excluding m ult icast fram es) . • Tx Multicast Pkts—Transm it m ult icast packet count er t hat increm ent s for each m ult icast valid fram e t ransm it t ed ( excluding broadcast fram es) . • Reset Counter but t on—click t o clear t he st at ist ics in t he Network Statistics page. EDITING UNIT PROPERTIES Unit propert ies are set during init ial set up, but can be changed at any t im e. See one of t he following: • “ Configure Basic Host Unit Propert ies” on page 64 • “ Label t he PRU/ URU” on page 66. CONFIGURING OPTICAL PORTS Opt ical port configurat ions are set during init ial set up, but can be changed at any t im e. See one of t he following: • See “ Label t he Host Opt ical Port s” on page 67. • See “ Label PRU/ URU Opt ical Port s” on page 70. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 153 © 2011 ADC Telecom m unicat ions, I nc. View ing t he St at us of t he Host Unit VIEWING THE STATUS OF THE HOST UNIT I n t he Syst em Tree, click on t he Host icon. I n t he Unit Menu bar, click Unit Information > View Status. The Unit Information > View Status page provides t he following inform at ion for t he select ed Host . The background of each t able cell is color coded t o t he level of t he alarm ; see “ Viewing Param et ers and Alarm s” on page 44. For furt her inform at ion on t hese fault s and alarm s, see “ Troubleshoot ing Alarm s” on page 185. • Module Status t able—provides st at us inform at ion for inst alled DARTs, where colum ns 1 t hrough 8 correspond t o t he slot in which t he DART resides ( Colum n 1 = Slot 1, and so fort h) . I f a DART colum n has no background color, a DART is not inst alled in t hat slot . – DART Fault—Sum m ary of DART Downconvert er 1 Synt hesizer Unlocked, Downconvert er 2 Synt hesizer Unlocked, Upconvert er Synt hesizer Unlocked, DC Supply Fault alarm s, and DART FPGA st at us. – DART Over Drive Fault—Red indicat es t hat t he RF signal received from t he BTS/ BDA is t oo st rong. Fault t hreshold is + 19 dBm . – DART Under Drive Fault—DART forward RF input signal below t he norm al operat ing lim it . Fault t hreshold is + 5 - Fwd Gain - 20 – Module Missing Fault—One of t he Host pluggable m odules is m issing ( DART/ SFP) . – DART Hardware Mismatch—Host DART does not support t he select ed passband. Fault occurs when a Host DART is replaced wit h anot her DART of t he incorrect t ype. • Optical Status t able—shows t he current usage and alarm st at us of t he opt ical port s on t he Host plus t he current values of som e key operat ing param et ers. Page 154 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s The Host has eight opt ical port s, but t he Optical Status t able only shows act ive port s ( physically connect ed t o a Rem ot e) . Each port in t he t able ( where SFP 1 is colum n 1, SFP 2 is colum n 2, and so fort h) represent s one set of forward and reverse pat hs bet ween a Host and Rem ot e. Physically, t his m ay have been accom plished wit h a dual- connect or t hrough t hat port . Each physical port cont ains an SFP t ransceiver wit h t wo connect ors. The Optical Status t able only shows t he Receive power level from t he Rem ot e Unit ( REV pat h) . To see t he Receive power level in t he FWD pat h ( from t he Host t o t he Rem ot e) , you m ust open t he Unit Information > View Status page for t he desired Rem ot e as described in “ Viewing t he St at us of a Rem ot e Unit ” on page 156. – Optical RX High BER—High bit error rat e ( BER) det ect ed by fiber opt ic receiver. Fault t hreshold is 0.00001. Threshold cannot be changed. – Optical RX No Light—No signal det ect ed by opt ical receiver. – Optical Transmitter Fault—SFP opt ical t ransm it t er failed. – Optical Over Drive—SFP opt ical receive input power above specificat ion. The fault t hreshold cannot be changed, and is 1 dBm for I R -9 dBm for LR. – Optical Under Drive—SFP opt ical receive input power below specificat ion. The fault t hreshold cannot be changed, and is -18 dBm for I R -27 dBm for LR. – Module Missing Fault—One of t he Host SFPs is m issing. • Host Status t able—shows t he current overall st at us of t he Host . – Host Major Contact Alarm Output Active—Maj or Cont act Alarm Out put act ive. – Host Minor Contact Alarm Output Active—Minor Cont act Alarm Out put act ive. – Remote Major Contact Alarm Output Active—Red indicat es NO/ NC m aj or alarm cont act s are in an alarm posit ion. These connect ions are t ypically wired t o a local alarm alert syst em . This st at us indicat or is red when a m aj or alarm is present on any Rem ot e connect ed t o t he Host . – Remote Minor Contact Alarm Output Active—Yellow indicat es t hat NO/ NC m inor alarm cont act s are in an alarm posit ion. These connect ions are t ypically wired t o a local alarm alert syst em . This st at us indicat or is yellow when a m inor alarm is present on any Rem ot e connect ed t o Host . – SeRF Fault—st at e of t he SeRF. Red indicat es t hat eit her t he SeRF clock source is unaccept able or t he SeRF card FPGA is not program m ed. – Fan Fault—st at e of t he Host chassis fan. Red indicat es t hat t he Host chassis fan is spinning t oo slowly. – Temperature High—Red indicat es t hat t he current t em perat ure of t he Host int erior is above it s operat ing lim it s. Fault t hreshold is 62° C. – Temperature Low—Yellow indicat es t hat t he current t em perat ure of t he Host int erior is below it s operat ing lim it s. Fault t hreshold is 0° C. • Temperature—Gives t he current t em perat ure of t he Host chassis int erior in degrees Cent igrade, as det ect ed by t he Host . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 155 © 2011 ADC Telecom m unicat ions, I nc. Viewing t he St at us of a Rem ot e Unit VIEWING THE STATUS OF A REMOTE UNIT For furt her inform at ion on t he fault s list ed in t he View St at us page for Rem ot e Unit s, see “ Troubleshoot ing Alarm s” on page 185. I n t he Syst em Tree, click on t he icon of t he PRU/ URU for which you want t o view it s st at us. I n t he Unit Menu bar, click Unit Information > View Status. The Unit Information > View Status page provides t he following inform at ion for t he select ed Rem ot e Unit . The background of each t able cell is color coded t o t he level of t he alarm ; see “ Viewing Param et ers and Alarm s” on page 44. For m ore inform at ion on t he fault s and alarm s, see “ Troubleshoot ing Alarm s” on page 185. Module Status Table The Module Status t able provides st at us inform at ion for PRU/ URU m odules where colum ns 1 t hrough 8 correspond t o t he slot in which a DART resides ( see “ RF Module Capabilit ies and GUI Represent at ion” on page 21) . The following sect ions describe t he different sect ions wit hin t he Module Status t able. Page 156 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s DART Status Table The DART Status t able present s st at us of t he DARTs in a Rem ot e Unit . There can be bet ween 1 and 8 DARTs inst alled in a Rem ot e Unit . I f a DART colum n has no background color, a DART is not inst alled in t hat slot , as shown below. The DART Status t able has t he following elem ent s. • DART Fault—Sum m ary of DART Downconvert er 1 Synt hesizer Unlocked, Downconvert er 2 Synt hesizer Unlocked, Upconvert er Synt hesizer Unlocked, DC Supply Fault alarm s, and DART FPGA st at us. • DART DC Supply Fault—DART Module DC supply volt ages out side specificat ion. • DART Hardware Mismatch—Host DART does not support t he select ed passband. Fault occurs when a Host DART is replaced wit h anot her DART of t he incorrect t ype. • DART Temperature High—DART t em perat ure above operat ing lim it . Threshold is 85° C. • Delay Out Of Range—PRU/ URU delay set t ings out side t he valid range. • DART Temperature Low—DART t em perat ure below operat ing lim it . Threshold is - 40° C. • Module Missing Fault—DART m odule is m issing. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 157 © 2011 ADC Telecom m unicat ions, I nc. Viewing t he St at us of a Rem ot e Unit LNA Status Table The LNA Status t able present s st at us inform at ion for t he Low Noise Am plifiers in a Rem ot e Unit . There can be bet ween 1 and 8 LNAs inst alled in a Prism Rem ot e Unit . • LNA Power Fault—PRU/ URU Low Noise Am plifier Power fault . • Module Missing Fault—LNA m odule is m issing. LPA Status Table The LPA Status t able present s st at us inform at ion for t he Linear Power Am plifiers in a Rem ot e Unit . There can be bet ween 1 and 4 LPAs inst alled in a Prism Rem ot e Unit . • LPA Disabled—PRU/ URU Linear Power Am plifier ( LPA) disabled due t o an int ernally det ect ed problem . ( VSWR, DC, Loop Fault , Low Power, or Tem perat ure High alarm ) . • LPA VSWR Fault—PRU/ URU Linear Power Am plifier ( LPA) VSWR fault . • LPA DC Fault—PRU/ URU Linear Power Am plifier ( LPA) DC fault . • LPA Loop Fault—PRU/ URU Linear Power Am plifier ( LPA) Loop fault . • LPA Over Power—PRU/ URU Linear Power Am plifier ( LPA) out put power level above operat ing lim it . • LPA Low Power Fault—I nt ernal Linear Power Am plifier ( LPA) Low Power fault . Gain of one or m ore int ernal am plifiers out side of specificat ion) . • LPA Missing—LPA m odule is m issing. • LPA Over Temperature—PRU/ URU LPA above operat ing lim it . Page 158 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s PD Status Table The PD Status t able present s st at us inform at ion for t he Power Det ect or in a Rem ot e Unit . There can be bet ween 1 and 4 PDs inst alled in a Prism Rem ot e Unit . • System VSWR Fault—PRU/ URU VSWR m easurem ent above specificat ion. • RF Power Low—PRU/ URU RF Out put Power below m inim um t hreshold. • Module Missing Fault—Power Det ect or m odule is m issing. • Duplexer Mismatch—Configured frequency range not support ed by Duplexer. Optical Status Table The Optical Status t able provides st at us inform at ion for SFPs inst alled in a Rem ot e Unit ( PRU/ URU) .There can be bet ween 1 and 8 SFPs inst alled in a Rem ot e Unit . I f a colum n has no background color, an SFP is not inst alled in t hat slot . • Optical RX High BER—High bit error rat e ( BER) det ect ed by fiber opt ic receiver. Threshold is 0.00001. • Optical RX No Light—No signal det ect ed by opt ical receiver. • Optical Transmitter Fault—SFP opt ical t ransm it t er failed. • Optical Over Drive—SFP opt ical Thresholds are as follows: – 1 dBm for I R – -9 dBm for LR. input power above specificat ion. • Optical Under Drive—SFP opt ical receive input Thresholds are as follows: – -18 dBm for I R – -27 dBm for LR. power below specificat ion. • Module Missing Fault—SFP m odule is m issing. receive FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 159 © 2011 ADC Telecom m unicat ions, I nc. Viewing t he St at us of a Rem ot e Unit Remote Status Table The Remote Status t able provides general st at us inform at ion for a Rem ot e Unit ( PRU/ URU) . • Host Lost—Host is not com m unicat ing wit h PRU/ URU. • AC Power Supply Fault—Power supply is in a failed st at e, or t he AC power is below t he m inim um required volt age. • Temperature High—Tem perat ure above operat ing lim it . Threshold is 95° C. • Temperature Low—Tem perat ure below operat ing lim it . Threshold is Minus 40° C. • Contact Alarm Input 1 Active—Host Cont act Alarm I nput # 1 act ive. • Fan Under Speed—Fans operat ing below expect ed RPM. • Contact Alarm Input 2 Active—Host Cont act Alarm I nput # 2 act ive. • Fan Over Speed—Fans operat ing above expect ed RPM. • Door Open—Door open on PRU. • SeRF Fault—Sum m ary of SeRF Synt hesizer Unlocked alarm and SeRF FPGA st at us. • Software Version Mismatch Fault—Soft ware version on t he Host and Rem ot e Unit s do not m at ch. Remote Unit Capacity and Temperature The Unit Information > View Status page for Rem ot e Unit s also provides unit capacit y and t em perat ure inform at ion for t he select ed Rem ot e Unit ( PRU/ URU) . • Capacity—t he num ber of RF groups available t o t he Rem ot e Unit . • Temperature—The int ernal Tem perat ure of t he select ed unit . Page 160 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s CLEARING DART CONFIGURATIONS This procedure does t he following: • reset s t he gain • reset s t he DART nam e • clears all links • clears t he passband • clears all associat ed alarm s I n t he Syst em Tree, click on an icon for a Host or Rem ot e Unit . I n t he Unit Menu bar, click Unit Configuration > Clear DART Configuration, t o open t he Clear DART Configuration page. I n t he Select colum n, select t he DART( s) for which you want t o clear configurat ion. Click Clear Configuration. I n t he confirm at ion window, click OK. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 161 © 2011 ADC Telecom m unicat ions, I nc. Set t he Capacit y for a New Rem ot e Unit RSI Board I f t he DART has been rem oved from t he Host or PRU/ URU chassis, t hen t he ent ire DART ent ry disappears. I f t he DART is st ill present in t he Host or PRU/ URU chassis, t hen t he DART Name and Passband is reset t o default . SET THE CAPACITY FOR A NEW REMOTE UNIT RSI BOARD The Capacity set t ing in t he Edit Properties page pert ains t o t he PRU/ URU Rem ot e SeRF I nt erface ( RSI ) board and t he num ber of RF groups available t o t he Rem ot e Unit . This param et er is set during m anufact uring and should be changed only when t he RSI board has been replaced. Using the EMS GUI to Change the Remote Unit Capacity The Capacity set t ing can be changed by logging ont o t he EMS t hrough t he Rem ot e Craft port . Open t he unit and connect your lapt op t o t he Craft port on t he SeRF. Login t o t he EMS, using t he following param et ers: • I P address is 192.168.0.1 • User Nam e is operator • Password is operator Page 162 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s I n t he Syst em Tree, click t he icon of t he PRU/ URU whose propert ies you want t o change. I n t he Unit Menu bar, click Unit Configuration > Edit Properties, t o open t he Unit Configuration > Edit Properties page for t he select ed PRU. I n t he Capacity list , set t he Capacity of t he new RSI board: • For all RSI boards inst alled in a URH, Capacity should always be set t o 3. • For an RSI board inst alled in a PRU, Capacity can be 1, 2, 3, or 4 and indicat es t he num ber of RF Modules inst alled in t he PRU. Click Apply. Using Telnet or ssh to Change the Remote Unit Capacity Alt ernat ely, t he capacit y can be changed using Telnet or ssh. Access t he Edit Unit Propert ies page t o det erm ine t he I P address for t he Host and Rem ot e Unit ( s) . I n t he Syst em Menu bar, click System Configuration > Edit Unit Properties. Each row in t he Edit Unit Properties t able correspond t o t he unit ident ified in t he Unit Id colum n. Use t he IP Address colum n t o det erm ine t he I P address for each unit . Login t o t he Host using telnet or ssh. From t he Host , login t o t he Rem ot e Unit using t he following com m and,where N is t he Rem ot e Unit I D ( 1 - 8) : sshremote N Once logged int o t he Rem ot e Unit , execut e t he following com m and, where X is t he capacit y ( 1- 4) : /usr/local/fwu/bin/EEPROMWriteForCapacity.sh X FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 163 © 2011 ADC Telecom m unicat ions, I nc. Reboot ing a Unit REBOOTING A UNIT CAUTION! The system configuration is stored on the Host. Rebooting the Host therefore results in a loss of RF for the Host and connected Remote Units until the Host comes back up. Depending on the system configuration, it can take 5 to 20 minutes before management communication is restored. CAUTION! Host configuration persists across a Reboot. However, the current EMS session will close and you will need to log back in to the EMS after the Host reboot has completed. CAUTION! Rebooting a Remote Unit causes Loss of Service and should not be used unless other troubleshooting processes have been followed and did not fix the issue being experienced at the PRU/URU. I n t he Syst em Tree, click on t he icon of t he unit t hat you want t o reboot . I n t he Unit Menu bar, click Unit Configuration > Reboot, t o open t he Unit Configuration > Reboot page. Click Reboot. • Once t he reboot st art s, a process m essage displays. • Aft er t he reboot has com plet ed, a Unit has been rebooted m essage displays. • Aft er t he Host reboot s, t he EMS login window opens. Page 164 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Managing Unit s RESETTING AN LPA CAUTION! Once an LPA Reset is started, Loss of Service occurs. It takes approximately 10 to 20 seconds before the LPA signal recovers. The GUI RF power reading will take longer depending on the number of Remotes equipped—for a fully loaded Prism system with 8 Remotes the power reading could take several minutes to update. NOTE: Only a user logged in under the admin or a Network Manager account can change Prism system settings through the EMS. You use t he LPA Reset but t on t o bring an LPA back int o service ( rest art ) t hat st opped because of a m aj or LPA alarm . I n a dual- LPA syst em , reset t ing t he LPA applies t o bot h LPAs at t he sam e t im e. To access t he Configure Remote Forward Gain page, in t he Syst em Menu bar, click System Configuration > Configure Remote Forward Gain. I n t he Remote Id list , select t he Rem ot e Unit whose LPA you need t o reset . I n t he Remote DART list , select t he DART whose LPA you need t o reset . Click t he LPA Reset but t on. I n t he LPA Reset caut ion dialog, click OK. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 165 © 2011 ADC Telecom m unicat ions, I nc. Reset t ing an LPA I nt ent ionally Blank Page Page 166 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 ALARMS Topics Page View Current Alarm s............................................................................................................. 168 Clear Current Alarm s ............................................................................................................ 170 View Alarm Hist ory ............................................................................................................... 170 Clearing Alarm Hist ory .......................................................................................................... 172 Filt ering t he Alarm Hist ory..................................................................................................... 172 Manage Alarm s .................................................................................................................... 174 Enable and Disable Host and Rem ot e Unit Alarm s ............................................................... 178 Set RF Power Low Threshold ............................................................................................ 180 Ant enna Disconnect Alarm ............................................................................................... 181 Manage Cont act Alarm s ........................................................................................................ 182 Acknowledge All Alarm s ........................................................................................................ 183 Clear All Disconnect Alarm s ................................................................................................... 184 Troubleshoot ing Alarm s ........................................................................................................ 185 Maj or Alarm s—Host Unit .................................................................................................. 185 Maj or Alarm s—Host Unit DARTs........................................................................................ 185 Maj or Alarm s—Host SeRF Modules .................................................................................... 187 Maj or Alarm s—Host Unit SFPs .......................................................................................... 188 Maj or Alarm s—Rem ot e Unit s ............................................................................................ 189 Maj or Alarm s—PRU/ URU DARTs........................................................................................ 189 Maj or Alarm s—PRU/ URU SeRF Modules.............................................................................. 191 Maj or Alarm s—PRU/ URU SFPs .......................................................................................... 193 Maj or Alarm s—PRU or URU Duplexer ................................................................................. 194 Maj or Alarm s—PRU or URU LNA ........................................................................................ 194 Maj or Alarm s—PRU or URU LPA ........................................................................................ 195 Maj or Alarm s—PRU or URU Power Det ect or ........................................................................ 196 Minor Alarm s—Host Unit DARTs ........................................................................................ 197 Minor Alarm s—Host Unit SeRF Module ............................................................................... 197 Minor Alarm s—Host Unit SFPs .......................................................................................... 198 Minor Alarm s—PRU/ URU DARTs ........................................................................................ 198 Minor Alarm s—PRU/ URU SeRF Modules.............................................................................. 199 Minor Alarm s—PRU/ URU SFPs .......................................................................................... 200 Minor Alarm s—PRU or URU LPAs ....................................................................................... 200 Cont act Alarm s—Host Syst em Card ................................................................................... 201 Cont act Alarm s—Rem ot e Unit .......................................................................................... 201 This sect ion describes how t o m anage and underst and t he alarm s t hat are report ed by t he EMS. This sect ion also provides corresponding Trap nam es. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 167 © 2011 ADC Telecommunications, Inc. View Current Alarm s VIEW CURRENT ALARMS To access t he View Current Alarms page, in t he Syst em Menu bar, click Alarms > View Current Alarms. ( For inform at ion on t he alarm color codes, see “ Alarm Color Codes” on page 44.) The View Current Alarms t able provides t he following inform at ion: • Severity—whet her t he alarm is classified as Maj or or Minor. • Ack’d—whet her checkm ark. • Alarm Code—syst em - assigned alarm code. • Alarm Name—descript ive nam e of alarm . • Timestamp—dat e and t im e when t he alarm occurred ( YYYY:MM:DD:HH:MM:SS) • Unit Id—ident ifies t he unit wit hin t he syst em t hat raised t he alarm ; see “ Unit I dent ificat ion” on page 43. • Unit Type—what t he unit is, such as Host or Rem ot e • Unit Name—nam e assigned t o t he unit • Module—t ype of m odule t hat is experiencing t he alarm ( SeRF, DART, LPA, LNA, Power Det ect or, SFP) • Module Name—user- assigned nam e for t he m odule. • RF Band—t ype of passband provided by t he DART. Page 168 © 2011 ADC Telecommunications, Inc t he alarm has been acknowledged, as indicat ed by FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s • Extended Info—link t hat once clicked opens anot her web page, which provides furt her inform at ion on t he alarm , including t roubleshoot ing inform at ion, as shown in t he following graphic. – Description—t ext descript ion of alarm – Remedy—what you can do t o correct t he alarm st at e – Threshold—value t hat once surpassed generat es an alarm – Notes—user- defined not es, if any, for t he unit . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 169 © 2011 ADC Telecom m unicat ions, I nc. Clear Current Alarm s CLEAR CURRENT ALARMS To access t he View Current Alarms page, in t he Syst em Menu bar, click Alarms > View Current Alarms. I n t he View Current Alarms page, click Clear Alarms. I n t he confirm at ion window, click OK. All current alarm s, wit h t he except ion of persist ent alarm s, are cleared from t he View Current Alarms t able. VIEW ALARM HISTORY To access t he View Alarm History page, in t he Syst em Menu bar, click Alarms > View Alarm History. ( For inform at ion on t he alarm color codes, see “ Alarm Color Codes” on page 44.) Page 170 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s The View Alarm History t able provides t he following inform at ion: • Severity—whet her t he alarm is classified as Maj or or Minor. • Ack’d—whet her checkm ark. • Alarm Code—syst em - assigned alarm code. • Alarm Name—descript ive nam e of alarm . • Timestamp—dat e and t im e when t he alarm occurred ( YYYY:MM:DD:HH:MM:SS) • Unit Id—ident ifies t he unit wit hin t he syst em t hat raised t he alarm ; see “ Unit I dent ificat ion” on page 43. • Unit Type—what t he unit is, such as Host or Rem ot e • Unit Name—nam e assigned t o t he unit • Module—t ype of m odule t hat is experiencing t he alarm ( SeRF, DART, LPA, LNA, Power Det ect or, SFP) • Module Name—user- assigned nam e for t he m odule. • RF Band—t ype of passband provided by t he DART. • First, Previous, Last but t ons—if t he View Alarm History t able is longer t han what can fit on a single web page, First, Previous, Last but t ons are included: – First—j um ps t he display t o t he first page of alarm s – Previous—j um ps t he display t o t he page of alarm s t hat you viewed im m ediat ely prior t o t he current page – Last—j um ps t he display t o t he last page of alarm s • Clear History but t on—see “ Clearing Alarm Hist ory” on page 172. t he alarm has been FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 acknowledged, as indicat ed by Page 171 © 2011 ADC Telecom m unicat ions, I nc. Clearing Alarm Hist ory CLEARING ALARM HISTORY To access t he View Alarm History page, in t he Syst em Menu bar, click Alarms > View Alarm History. Click Clear History. I n t he confirm at ion window, click OK. The View Alarm History page is cleared. FILTERING THE ALARM HISTORY The View Alarm History page allows you t o filt er, or select , which alarm hist ories you want t o page. To access t he View Alarm History page, in t he Syst em Menu bar, click Alarms > View Alarm History. Do t he following in t he Filter panel: I n t he View list , select how you want t o filt er t he alarm s: • None—all alarm s display • Unit Name—filt er by t he user- assigned nam e of a unit • Host Number—filt er by t he syst em - assigned num ber for t he Host • Remote Number—filt er by t he syst em - assigned num ber for a Rem ot e • Event Name—filt er by an event ( alarm or incident ) nam e. Page 172 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s I n t he contains box, ent er t he crit eria by which you want t o filt er t he alarm hist ory list . Click Filter. The View Alarm History page refreshes, and now list s only t hose alarm s t hat m eet t he specified filt er crit eria. I n t his exam ple, only t hose event s wit h t he word “ DART” in t hem display. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 173 © 2011 ADC Telecom m unicat ions, I nc. Manage Alarm s To rem ove t he filt er: I n t he View list , select None. Delet e any t ext from t he contains box. Click Filter. MANAGE ALARMS To access t he Manage Alarms page, in t he Syst em Menu bar, click Alarms > Manage Alarms. • For an exam ple of a Manage Alarms page for a Host Unit , see Figure 23 on page 175 and Figure 24 on page 176. • For an exam ple of a Manage Alarms page for a Rem ot e Unit , see Figure 25 on page 177 and Figure 26 on page 178. The Manage Alarms page has t he following elem ent s: • Select m enu—has t he following im plem ent at ions: – Global—displays alarm s for t he Host and all connect ed Rem ot e Unit s. Please not e, however, t hat t his view does not reflect t he current st at us of alarm enable/ disable condit ions—it is designed t o show you at a glance t hose alarm s t hat can be m anaged. To effect a change in t he m anagem ent of an alarm and t o see t he current st at e of an alarm , select a specific unit . – Unit name—each unit in t he syst em is list ed by nam e, which allows you t o select for which unit you want t o m anage alarm s. • Antenna Disconnect Severity m enu—see “ Ant enna Disconnect Alarm ” on page 181. • Unit field—what t ype of unit t he alarm pert ains t o: – Host – Remote • Module field—which m odule t he alarm pert ains t o: – DART—can be up t o eight DARTs list ed – LNA—can be up t o t wo LNAs list ed – Power Detector – SFP—can be up t o eight SFPs list ed – SeRF • Alarm Name field—ident ifies t he alarm by nam e; see Table 23 on page 178. NOTE: For definitions of the alarms listed above, see “Troubleshooting Alarms” on page 185. • Enabled select ion box—select t o enable alarm report ing for t he corresponding alarm . • Threshold Value field—value t hat once surpassed generat es t he specified alarm ; see Table 23 on page 178. Page 174 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Figure 23. Example of Manage Alarms Page—Host Unit Part 1 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 175 © 2011 ADC Telecom m unicat ions, I nc. Manage Alarm s Figure 24. Example of Manage Alarms Page—Host Unit Part 2 Page 176 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Figure 25. Example of Manage Alarms Page—Remote Unit Part 1 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 177 © 2011 ADC Telecom m unicat ions, I nc. Manage Alarm s Figure 26. Example of Manage Alarms Page—Remote Unit Part 2 Enable and Disable Host and Remote Unit Alarms The Manage Alarms page allows you t o enable and disable alarm report ing for t he alarm s list ed in Table 23 on page 178. Table 23. Alarms That Can Be Enabled/Disabled Unit Module Alarm Remote RDI AC Power Supply 1 Fault Remote RDI AC Power Supply 2 Fault Remote RDI AC Power Supply 3 Fault Remote RDI AC Power Supply 4 Fault Remote PRU/URU AC Power Supply Fault Page 178 © 2011 ADC Telecommunications, Inc Alarm Threshold FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Table 23. Alarms That Can Be Enabled/Disabled (Cont.) Unit Module Alarm Alarm Threshold Host DART DART ALC Limiting +19 - Fwd Gain dBm Host DART DART DC Supply Fault Remote DART DART DC Supply Fault Host DART DART Over Drive +19 dBm Remote DART DART Temperature High 85 Deg C Remote DART DART Temperature Low minus 40 deg C Host DART DART Under Drive +5 - Fwd Gain - 20 dBm Remote SeRF Door Open Remote DART Downconvert Fault Remote DART DART DC Supply Fault Remote SFP Excess Connections Host DART FLM Downconvert Fault Remote DART FWD Cal Tone Fault Remote SFP Invalid Device Connection Remote LNA LNA Power Fault Host SFP Optical Over Drive 1 dBm(IR)/-9dBm(LR) Remote SFP Optical Over Drive 1 dBm(IR)/-9dBm(LR) Host SFP Optical RX High BER 0.00001 Remote SFP Optical RX High BER 0.00001 Host SFP Optical RX No Light Remote SFP Optical RX No Light Host SFP Optical Under Drive -18 (IR) dBm/-27 dBm (LR) Remote SFP Optical Under Drive -18 dBm (IR)/ -27 dBm (LR) Remote DART REV Test Tone Low Remote PD RF Power Low Host DART RLM Upconvert Fault Host DART RLM Upconvert Indeterminate Remote SeRF Software Version Mismatch Fault Remote PD System VSWR Fault 3:1 Host SeRF Temperature High 62 Deg C Remote SeRF Temperature High 95 Deg C PRU/URU SeRF Temperature High 62 Deg C Host SeRF Temperature Low 0 Deg C Remote SeRF Temperature Low Minus 40 Deg C PRU/URU SeRF Temperature Low 0 Deg C Remote LPA Under Power Remote DART Upconvert Fault Remote DART Upconvert Indeterminate Remote DART Uplink Inactivity Fault 0 dBm* 10 dB above the noise floor. * You can manually set the threshold for RF Power Low; see “Set RF Power Low Threshold” on page 180 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 179 © 2011 ADC Telecom m unicat ions, I nc. Manage Alarm s Do t he following t o enable/ disable alarm report ing: To access t he Manage Alarms page, in t he Syst em Menu bar, click Alarms > Manage Alarms. I n t he Select list , select t he Rem ot e Unit for which you want t o change t he t hreshold of t he RF Power Low alarm . I n t he Threshold Value box for t he RF Power Low alarm , ent er t he new t hreshold, which m ust be bet ween 0 dB - 40 dB. Click Apply. Set RF Power Low Threshold The following rules apply t o set t ing alarm t hresholds: • Only t he t hreshold for t he RF Power Low alarm can be changed. • Only users wit h Net work Manager or Adm in privileges can perform t his procedure. • Alarm t hresholds cannot be set t hrough SNMP MI Bs. • I f you perform a Reset to Factory Defaults, t he alarm t hreshold values are reset ; you will need t o be reconfigure t he alarm t hreshold values, as necessary. • Alarm t hreshold values are configured by unit —t hey cannot be set globally for all unit s in t he syst em . Do t he following t o set t he RF Power Low alarm t hreshold: To access t he Manage Alarms page, in t he Syst em Menu bar, click Alarms > Manage Alarms. I n t he Select list , select t he Rem ot e Unit for which you want t o change t he t hreshold of t he RF Power Low alarm . I n t he Threshold Value box for t he RF Power Low alarm , ent er t he new t hreshold, which m ust be bet ween 0 dB - 40 dB. Click Apply. Page 180 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Antenna Disconnect Alarm I n t he Manage Alarms page, t here is an Antenna Disconnect Severity m enu, which pert ains only t o Rem ot e Access Unit s ( RAUs) in an I nt erReach Spect rum syst em . This feat ure is t herefore not applicable t o a FlexWave Prism syst em and should not be changed from it s default set t ing. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 181 © 2011 ADC Telecom m unicat ions, I nc. Manage Cont act Alarm s MANAGE CONTACT ALARMS To access t he Manage Contact Alarms page, in t he Syst em Menu bar, click Alarms > Manage Contact Alarms. I n t he Select m enu, select for which unit cont act alarm s are t o be configured. The Manage Contact Alarms page has t he following Read- Only elem ent s: • Unit Name—nam e assigned t o t he unit • Contact Alarm—nam e assigned t o t he cont act alarm I n t he Severity list , set t he severit y level of t he cont act alarm : • Minor ( default ) • Major I n t he Mode list , set t he m ode for t he cont act alarm : • Normally Open ( default ) • Normally Closed I n t he Name box, ent er a nam e for t his alarm . • Ent er bet ween 1 and 255 alphanum eric charact ers. Spaces and Underscores are allowed, except t hey cannot be used as t he first charact er. • I f you do not want t o nam e t he alarm , leave t he Name box em pt y. I n t he Enabled select ion box for t he alarm t hat you want t o m anage, do one of t he following: • Select t he Enabled checkbox t o enable alarm report ing for t his alarm t ype. • Rem ove ( deselect ) t he checkm ark from t he Enabled checkbox t o disable alarm report ing for t his alarm t ype. Click Apply. Page 182 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s ACKNOWLEDGE ALL ALARMS To access t he Acknowledge All Alarms page, in t he Syst em Menu bar, click Alarms > Acknowledge All Alarms. Click Acknowledge All. I n t he confirm at ion window, click OK. An All alarms have been acknowledged m essage displays. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 183 © 2011 ADC Telecom m unicat ions, I nc. Clear All Disconnect Alarm s CLEAR ALL DISCONNECT ALARMS NOTE: Clear All Disconnects is not applicable to the Host—it is applicable only to PRUs. CAUTION! This procedure removes all information related to the disconnected units from the configuration database. To access t he Clear All Disconnects page, in t he Syst em Menu bar, click Alarms > Clear All Disconnects. Click Clear All Disconnects. Aft er approxim at ely one m inut e, t he Syst em Tree updat es by rem oving t he disconnect overlay from t he unit icon( s) . ( For an exam ple of t he disconnect overlay, see Table 11 on page 42.) Page 184 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s TROUBLESHOOTING ALARMS This sect ion list s and defines alarm s t hat t he FlexWave Prism EMS report s, and provides rem edies for t hose alarm s. The MI B Trap nam e for each alarm is also list ed. Major Alarms—Host Unit Ala r m : Re m ot e Lost Trap: fwuHstSERFRmtLostFault Alarm Code: Definition: Remedy: AC1 Rem ot e Unit ( PRU/ URU) not com m unicat ing wit h Host . Check t hat t he PRU/ URU has power and t hat t he power swit ch is on. Check t hat at least one Host SFP is connect ed t o t his PRU/ URU and has accept able RX power. Major Alarms—Host Unit DARTs Ala r m : D ART D C Su pply Fa u lt Trap: fwuHstDARTDCSupplyFault Alarm Code: Definition: Remedy: AC28 DART card DC supply volt ages out side specificat ion. Check whet her t he Host supply volt age is in t he range of 21- 60 VDC. I f t he volt age is correct and t he alarm persist s for 5 m inut es ( m ay be t ransient on st art up) , replace t he DART. Ala r m : D ART D ow n con ve r t e r 1 Syn t h e size r Unlock e d Trap: fwuHstDARTDwnCon1SynLockFault Alarm Code: Definition: Remedy: AC25 DART downconvert er 1 synt hesizer unlocked. The Downconvert er 1 Synt hesizer Unlocked alarm can occur during Host reboot s and DART hot swaps. I f t he alarm persist s aft er 5 m inut es, replace t he DART. Ala r m : D ART D ow n con ve r t e r 2 Syn t h e size r Unlock e d Trap: fwuHstDARTDwnCon2SynLockFault Alarm Code: Definition: Remedy: AC26 DART downconvert er 2 synt hesizer unlocked. The Downconvert er 2 Synt hesizer Unlocked alarm can occur during Host reboot s and DART hot swaps. I f t he alarm persist s aft er 5 m inut es, replace t he DART. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 185 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Ala r m : D ART Fa u lt Trap: fwuHstDARTFault Alarm Code: Definition: Remedy: AC29 Sum m ary of DART Downconvert er 1 Synt hesizer Unlocked, Downconvert er 2 Synt hesizer Unlocked, Upconvert er Synt hesizer Unlocked, DC Supply Fault alarm s, and DART FPGA st at us. I nspect alarm s ( Alarms View Current Alarms) for upconvert er/ downconvert er/ DC supply alarm s on t he sam e Host DART and follow t he rem edies for t hose alarm s. I f none of t hese alarm s are found, unplug and replug t he DART in t he Host . I f t he alarm persist s, replace t he DART. Ala r m : D ART H a r dw a r e M ism a t ch Trap: fwuHstDARTHardwareMismatchFault Alarm Code: Definition: Remedy: AC32 Host DART does not support t he select ed passband. Fault occurs when a Host DART is replaced wit h anot her DART of t he incorrect t ype. I nst all a DART t hat support s t he select ed passband. I f t he Host DART posit ion is t o be changed t o a different frequency band, rem ove and clear t he DART configurat ion ( Unit Configuration > Clear DART Configuration) , inst all t he new DART, set t he passband, and est ablish t he new link ( System Configuration > Configure DART Links) . Ala r m : D ART Ove r D r ive Trap: fwuHstDARTOverDriveFault Alarm Code: Definition: Threshold: Remedy: AC30 DART forward RF input t oo high. + 19 dBm Reduce t he Host DART forward RF input level. Ala r m : D ART Upcon ve r t e r Syn t h e size r Un lock e d Trap: fwuHstDARTUpConSynLockFault Alarm Code: Definition: Remedy: AC27 DART upconvert er synt hesizer unlocked. The DART Upconvert er Synt hesizer Unlocked alarm can occur during Host reboot s and DART hot swaps. I f t he alarm persist s aft er 5 m inut es, replace t he DART. Ala r m : FLM D ow n con ve r t e r Fa u lt Trap: fwuHstBTSFLMFailFault Alarm Code: Definition: Remedy: AC47 Forward Link Monit or ( FLM) fault act ive. I f alarm persist s, t hen replace t he DART. Page 186 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Ala r m : M odu le M issin g Fa ult Trap: fwuHstModuleMissingFault Alarm Code: Definition: Remedy: AC2 One of t he Host pluggable m odules is m issing ( DART/ SFP) . Eit her replace Host m odule or clear DART configurat ion ( Unit Configuration > Clear DART Configuration) . Ala r m : RLM Upcon ve r t Fa u lt Trap: fwuHstRLMUpconvertFailureFault Alarm Code: Definition: Remedy: AC48 Reverse Link Monit or ( RLM) fault act ive. Running Syst em Test ( System Configuration > Perform System Test) wit h un- t erm inat ed Host DARTs m ay cause a false RLM Upconvert Fault. Ensure t hat all Host DARTs are t erm inat ed before running Syst em Test . I f alarm persist s, t hen replace t he DART. Major Alarms—Host SeRF Modules Ala r m : Fa n Fa u lt Trap: fwuHstSysCardFanFault Alarm Code: Definition: Remedy: AC6 Fan not funct ioning. Verify int ake and exhaust vent s are clear of obst ruct ions and/ or debris. I f alarm persist s, replace Fan Module. Ala r m : Se RF Fa u lt Trap: fwuHstSERFFault Alarm Code: Definition: AC10 Sum m ary of SeRF Synt hesizer Unlocked alarm and SeRF FPGA st at us. Check for relat ed Host SeRF alarm s ( Alarms > View Current Alarms) . I f no SeRF alarm s exist , FPGA is fault y; replace Host SeRF Module. Remedy: Ala r m : Se RF Syn t h e size r Un lock e d Trap: fwuHstSERFSynthAlarmFault Alarm Code: Definition: Remedy: AC9 SeRF synt hesizer unlocked. Check Host reference clock set t ings ( Unit Configuration > Edit Properties) . Reseat t he Syst em Module. I f reference clock source is ext ernal, verify 10 MHz clock source and connect ion. I f reference clock source is int ernal and t he alarm s persist s, replace t he Host Syst em Module. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 187 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Ala r m : Te m pe r a t u r e H igh Trap: fwuHstOverTempFault Alarm Code: Definition: Threshold: Remedy: AC4 Tem perat ure above operat ing lim it . 62° C Check for Host Fan Fault alarm ( Alarms > View Current Alarms) . Verify t hat am bient t em perat ure is less t han 50° C. Verify Host air int ake and exhaust vent s are clear of debris. Major Alarms—Host Unit SFPs Ala r m : Opt ica l Ove r D r ive Trap: fwuHstSERFOptOverDriveFault Alarm Code: Definition: Threshold: Remedy: AC16 SFP opt ical receive input power above specificat ion. Threshold for I R is 1 dBm , and for LR is - 9 dBm Reduce t he opt ical receive level by adding opt ical at t enuat ion. Replace opt ical at t enuat or if fault y. Ala r m : Opt ica l RX N o Ligh t Trap: fwuHstSERFOptRxNoLightFault Alarm Code: Definition: Remedy: AC14 No signal det ect ed by opt ical receiver. Check for broken fiber opt ic cable; replace if found. Check for disconnect ed fiber opt ic cable; reconnect cable if necessary. Check t hat t he PRU/ URU has power. Ala r m : Opt ica l Tr a n sm it t e r Fa u lt Trap: fwuHstSERFOptLaserFault Alarm Code: Definition: Remedy: AC15 SFP opt ical t ransm it t er failed. Replace Host SFP. Page 188 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Major Alarms—Remote Units The following alarm s apply t o bot h t he Prism Rem ot e Unit ( PRU) and t he URH Rem ot e Unit ( URU) . Ala r m : M odu le M issin g Fa ult Trap: fwuRmtModuleMissingFault Alarm Code: Definition: AC68 A pluggable m odule is m issing from a Rem ot e Unit , and can be any of t he following: DART, SFP, LNA, LPA, or PD. Eit her replace t he PRU/ URU m odule or clear DART configurat ion ( Unit Configuration > Clear DART Configuration) . Remedy: Major Alarms—PRU/URU DARTs The following alarm s apply t o DARTs inst alled in a Prism Rem ot e Unit ( PRU) or a URH Rem ot e Unit ( URU) . Ala r m : D ART D C Su pply Fa u lt Trap: fwuRmtDARTDCSupplyFault Alarm Code: Definition: Remedy: AC97 DART card DC supply volt ages out side specificat ion. I f t he alarm persist s for 5 m inut es ( m ay be t ransient on st art up) , replace t he DART. Ala r m : D ART Fa u lt Trap: fwuRmtDARTFault Alarm Code: Definition: AC101 Sum m ary of DART Downconvert er 1 Synt hesizer Unlocked, Downconvert er 2 Synt hesizer Unlocked, Upconvert er Synt hesizer Unlocked, DC Supply Fault alarm s, and DART FPGA st at us. I nspect alarm s ( Alarms View Current Alarms) for upconvert er/ downconvert er/ DC supply alarm s on t he PRU/ URU DART and follow t he rem edies for t hose alarm s. For PRU DART only—if none of t hese alarm s are present , power cycle t he RF Module. I f t he alarm persist s, replace t he RF Module. Remedy: FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 189 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Ala r m : D ART H a r dw a r e M ism a t ch Trap: fwuRmtDARTHardwareMismatchFault Alarm Code: Definition: Remedy: AC98 Host DART does not support t he select ed passband. Fault occurs when a Host DART is replaced wit h anot her DART of t he incorrect t ype. I nst all a DART t hat support s t he select ed passband. I f t he posit ion of t he PRU/ URU DART is t o be changed t o a different frequency band, rem ove and clear t he DART configurat ion ( Unit Configuration > Clear DART Configuration) , inst all t he new DART, set t he passband, and est ablish t he new link ( System Configuration > Configure DART Links) . Ala r m : D ow n con ve r t Fa u lt Trap: fwuRmtDownconvertfailureFault Alarm Code: Definition: AC128 Band specific alarm raised during Reverse Link Monit oring on PRU/ URU. Ret ry Syst em Test ( System Configuration > Perform System Test) . I f alarm persist s, replace t he DART. Remedy: Ala r m : D ow n con ve r t e r 1 Syn t h e size r Un lock e d Trap: fwuRmtDARTDwnCon1SynLockFault Alarm Code: Definition: Remedy: AC93 DART downconvert er 1 synt hesizer unlocked. The Downconvert er 1 Synt hesizer Unlocked alarm can occur during Host reboot s and DART hot swaps. I f t he alarm persist s aft er 5 m inut es, replace t he DART. Ala r m : D ow n con ve r t e r 2 Syn t h e size r Un lock e d Trap: fwuRmtDARTDwnCon2SynLockFault Alarm Code: Definition: Remedy: AC94 DART downconvert er 2 synt hesizer unlocked. The Downconvert er 2 Synt hesizer Unlocked alarm can occur during Host reboot s and DART hot swaps. I f t he alarm persist s aft er 5 m inut es, replace t he DART. Ala r m : FW D Ca l Ton e Fa u lt Trap: fwuRmtDownlinkCalToneFailureFault Alarm Code: Definition: Remedy: AC124 Forward calibrat ion t one not at expect ed level. Ret ry Syst em Test ( System Configuration > Perform System Test) . I f alarm persist s, replace t he DART. Page 190 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Ala r m : REV Te st Ton e Low Trap: fwuRmtUplinkFailureDetectLowFault Alarm Code: Definition: Remedy: AC125 Reverse t est t one not at expect ed level. Ret ry Syst em Test ( System Configuration > Perform System Test) . I f alarm persist s, replace t he DART. Ala r m : Upcon ve r t Fa u lt Trap: fwuRmtUpconvertfailureFault Alarm Code: Definition: AC126 Band specific alarm raised during Forward Link Monit oring on PRU/ URU. Ret ry Syst em Test ( System Configuration > Perform System Test) . I f alarm persist s, replace t he DART. Remedy: Ala r m : Upconve r t I nde t e r m ina t e Trap: fwuRmtUpconIndetFault Alarm Code: Definition: AC129 Band specific alarm raised during Forward Link Monit oring on PRU/ URU. Ret ry Syst em Test ( System Configuration > Perform System Test) . I f alarm persist s, replace t he DART. Remedy: Ala r m : Upcon ve r t e r Syn t h e size r Un lock e d Trap: fwuRmtDARTUpConSynLockFault Alarm Code: Definition: Remedy: AC95 DART upconvert er synt hesizer unlocked. The DART Upconvert er Synt hesizer Unlocked alarm can occur during Host reboot s and DART hot swaps. I f t he alarm persist s aft er 5 m inut es, replace t he DART. Major Alarms—PRU/URU SeRF Modules The following alarm s apply t o a SeRF m odule inst alled in a Prism Rem ot e Unit ( PRU) or in a URH Rem ot e Unit ( URU) . Ala r m : Fa n Un de r Spe e d Trap: fwuRmtFanUnderSpeedFault Alarm Code: Definition: Remedy: AC77 Fans operat ing below expect ed RPM. Verify int ake and exhaust vent s are clear of obst ruct ions and/ or debris. I f alarm persist s, replace Fan Module. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 191 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Ala r m : H ost Lost Trap: fwuRmtSeRFHstLostFault Alarm Code: Definition: Remedy: AC88 Host not com m unicat ing wit h PRU/ URU. Check t hat t he Host has power and t hat t he power swit ch is on. Check t hat at least one of t he PRU/ URU SFPs is connect ed t o t his Host and has accept able RX power. Ala r m : Se RF Fa u lt Trap: fwuRmtSERFFault Alarm Code: Definition: AC87 Sum m ary of SeRF Synt hesizer Unlocked alarm and SeRF FPGA st at us. Check for relat ed Host SeRF alarm s ( Alarms > View Current Alarms) . I f no SeRF alarm s exist , FPGA is fault y; replace PRU SeRF Module. Remedy: Ala r m : Se RF Syn t h e size r Un lock e d Trap: fwuRmtSERFSynthAlarmFault Alarm Code: Definition: Remedy: AC86 SeRF synt hesizer unlocked. Ensure t hat t he PRU/ URU has an opt ical input signal. Check t hat t he Host reference clock is properly configured and is not in alarm ; ot herwise replace t he PRU/ URU SeRF m odule. Ala r m : Te m pe r a t u r e H igh Trap: fwuRmtOverTempFault Alarm Code: Definition: Threshold: Remedy: AC73 Tem perat ure above operat ing lim it . 95° C Check for PRU/ URU Fan Fault alarm ( Alarms > View Current Alarms) . Verify t hat am bient t em perat ure is less t han 50° C. Verify t hat t he air int ake and exhaust vent s for t he PRU/ URU are clear of debris. Page 192 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Major Alarms—PRU/URU SFPs The following alarm s apply t o SFPs inst alled in a Prism Rem ot e Unit ( PRU) or in a URH Rem ot e Unit ( URU) . NOTE: Cascading Remote Units is not supported in this release. Alarms that pertain to cascaded Remote Units are included as reference only. Ala r m : Ex ce ss Con n e ct ion s Trap: fwuRmtExcessConnFault Alarm Code: Definition: AC134 Two or m ore PRU/ URU connect ed t o a single cascaded PRU/ URU, or a nint h PRU/ URU connect ed in cascade, or t here are m ore out going fibers t han incom ing fibers on a PRU/ URU in a cascade. Connect fiber opt ic cables per cascade connect ion rules. Refer t o appropriat e inst allat ion guide for det ails. Remedy: Ala r m : Fibe r Con n e ct ion M ism a t ch Trap: fwuRmtFiberConnMismatchFault Alarm Code: Definition: AC133 Fiber opt ic cable connect ions bet ween cascaded PRU/ URUs not following SFP connect ion rules. Connect fiber opt ic cables per cascade connect ion rules. Refer t o appropriat e inst allat ion guide for det ails. Remedy: Ala r m : I n va lid D e vice Con n e ct ion Trap: fwuRmtInvalidDevConnFault Alarm Code: Definition: Remedy: AC135 PRU/ URU is connect ed t o a DRU or vice versa. Ensure t hat cascaded Rem ot es are all t he sam e t ype ( t hat is, a PRU t o a PRU and a DRU t o a DRU) . Refer t o appropriat e inst allat ion guide for det ails. Ala r m : Opt ica l Ove r D r ive Trap: fwuRmtSERFOptOverDriveFault Alarm Code: Definition: Threshold: Remedy: AC84 SFP opt ical receive input power above specificat ion. Threshold for I R is 1 dBm , and for LR is - 9 dBm Reduce t he opt ical receive level by adding opt ical at t enuat ion. Replace opt ical at t enuat or if fault y. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 193 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Ala r m : Opt ica l RX N o Ligh t Trap: fwuRmtSERFOptRxNoLightFault Alarm Code: Definition: Remedy: AC82 No signal det ect ed by opt ical receiver. Check/ repair opt ical overdrive condit ions ( Unit Information > View Optical Ports) . Ensure t hat fiber opt ic connect ions are clean. Check for kinks or sharp bends in t he fiber opt ic cable; replace fiber opt ic cable if unable t o correct any problem s found. Ala r m : Opt ica l Tr a n sm it t e r Fa u lt Trap: fwuRmtSERFOptLaserFault Alarm Code: Definition: Remedy: AC83 SFP opt ical t ransm it t er failed. Replace Host SFP. Major Alarms—PRU or URU Duplexer The following alarm s apply t o Duplexers, which are inst alled in t he Prism Rem ot e Unit ( PRU) or t he URH Rem ot e Unit ( URU) . Ala r m : D u ple x e r M ism a t ch Trap: fwuRmtDuplexerFreqMismatchFault Alarm Code: Definition: Remedy: AC116 Configured frequency range not support ed by Duplexer. Change DART passband t o fit wit hin duplexer frequency range ( System Configuration > Configure DART Links). I f alarm persist s, cont act ADC. Major Alarms—PRU or URU LNA The following alarm s apply t o LNAs inst alled in a Prism Rem ot e Unit ( PRU) or URH Rem ot e Unit ( URU) . Ala r m : LN A Pow e r Fa u lt Trap: fwuRmtLNAPowerFault Alarm Code: Definition: Remedy: AC115 PRU/ URU Low Noise Am plifier ( LNA) Power fault . The low noise am plifier has an int ernal error. I f alarm persist s, replace t he RF Module. Page 194 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Major Alarms—PRU or URU LPA The following alarm s apply t o LPAs inst alled in a Prism Rem ot e Unit ( PRU) or URH Rem ot e Unit ( URU) . Ala r m : LPA D C Fa u lt Trap: fwuRmtLPADcFault Alarm Code: Definition: Remedy: AC109 PRU/ URU Linear Power Am plifier ( LPA) DC fault . Caused by int ernally det ect ed problem wit h t he LPA. I m pact is loss of RF service. Reset LPA. I f alarm persist s, replace t he RF Module. Ala r m : LPA D isa ble d Trap: fwuRmtLPADisableFault Alarm Code: Definition: AC105 PRU/ URU Linear Power Am plifier ( LPA) disabled due t o an int ernally det ect ed problem . ( VSWR, DC, Loop Fault , Low Power, or Tem perat ure High alarm ) . The LPA is disabled because of an int ernally det ect ed problem . Perform an LPA Reset . I f t he fault persist s replace t he RF Module. Remedy: Ala r m : LPA Loop Fa u lt Trap: fwuRmtLPALoopFault Alarm Code: Definition: Remedy: AC110 PRU/ URU Linear Power Am plifier ( LPA) Loop fault . Caused by int ernally det ect ed problem wit h t he LPA. I m pact is loss of RF service. Lower DART( s) gain by 10 dB, reset t he LPA, and ret urn gain t o previous value. I f alarm persist s, replace RF Module. Ala r m : LPA Low Pow e r Fa u lt Trap: fwuRmtLPALowPowerFault Alarm Code: Definition: AC111 I nt ernal Linear Power Am plifier ( LPA) Low Power fault . Gain of one or m ore int ernal am plifiers out side of specificat ion) . Caused by int ernally det ect ed problem wit h t he LPA. I m pact is loss of RF service. Reset LPA. I f alarm persist s, replace t he RF Module. Remedy: Ala r m : LPA M issin g Trap: fwuRmtLPADetectFault Alarm Code: Definition: Remedy: AC112 Linear Power Am plifier ( LPA) det ect ion fault . LPA m issing from PRU. Cause is fault y RF Module. I m pact is loss of RF service. I f alarm persist s, replace t he RF Module. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 195 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Ala r m : LPA Ove r Pow e r Trap: fwuRmtLPAOverPowerFault Alarm Code: Definition: Threshold: Remedy: AC107 PRU/ URU Linear Power Am plifier ( LPA) out put power level above operat ing lim it . Variable by LPA band. Causes include, forward pat h gains are set t oo high or Host RF input levels are t oo high. I m pact is loss of RF service. Reduce PRU forward gain ( " Syst em Configurat ion - > Configure Rem ot e Forward Gain" ) . Reset t he LPA, and t hen m onit or RF out put power levels. Adj ust gain t o accept able values. I f t he alarm persist s, replace t he RF Module. Ala r m : LPA VSW R Fa u lt Trap: fwuRmtLPAVswrFault Alarm Code: Definition: Threshold: Remedy: AC108 PRU/ URU Linear Power Am plifier ( LPA) VSWR fault . 3: 1 Causes include, fault y RF Module, fault y/ loose RF Module t o bulkhead cable, fault y/ loose ext ernal light ning arrest or, cable or ant enna. I m pact is loss of RF service. Reset LPA. I f alarm persist s, replace t he RF Module. Major Alarms—PRU or URU Power Detector Ala r m : RF Pow e r Low Trap: fwuRmtRFPowerFault Alarm Code: Definition: Threshold: AC114 PRU/ URU RF Out put Power below m inim um t hreshold. 0 dBm ; can be configured by user, see “ Set RF Power Low Threshold” on page 180. Check for Host DART underdrive alarm or low RF input from BTS. Check t he Host and Rem ot e forward gains are set correct ly. Remedy: Ala r m : Syst e m VSW R Fa u lt Trap: fwuRmtSystemVswrFault Alarm Code: Definition: Threshold: Remedy: AC113 PRU/ URU VSWR m easurem ent above specificat ion. 3: 1 Perform cable sweeps on ext ernal ant enna cable syst em . Put a load on t he PRU/ URU by disconnect ing t he ext ernal ant enna cable t o det erm ine if t he source of t he VSWR condit ion is int ernal or ext ernal. I f int ernal, replace t he RF Module. I f ext ernal, t roubleshoot and det erm ine source of high VSWR reading. Page 196 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Minor Alarms—Host Unit DARTs Ala r m : D ART ALC Lim it in g Trap: fwuHstDARTALCLimitingFault Alarm Code: Definition: Threshold: Remedy: AC33 Host DART forward pat h Aut om at ic Level Cont rol act ive. + 19 - Fwd Gain Decrease t he Host DART forward pat h gain ( System Configuration > Configure Host Forward Gain) , or reduce t he RF signal level from t he BTS/ BDA. Ala r m : D ART Un de r D r ive Trap: fwuHstDARTUnderDriveFault Alarm Code: Definition: Threshold: Remedy: AC31 DART forward RF input signal below t he norm al operat ing lim it . + 5 - Fwd Gain - 20 Check t hat an RF signal is present at t he Host DART forward input . I f an RF signal is present , t hen increase t he forward gain of t he Host DART. I f t he alarm does not clear when gain is at m axim um , increase t he power of t he BTS/ BDA RF signal. Ala r m : RLM Upconve r t I n de t e r m ina t e Trap: fwuHstRLMUpConIndetFault Alarm Code: Definition: Remedy: AC49 Unable t o run RLM due t o Host Reverse Gain being set t oo low. I ncrease Host Reverse Gain ( System Configuration > Configure Host Forward Gain). Minor Alarms—Host Unit SeRF Module Ala r m : Te m pe r a t u r e Low Trap: fwuHstUnderTempFault Alarm Code: Definition: Threshold: Remedy: AC5 Tem perat ure below operat ing lim it . 0° C Verify t hat am bient t em perat ure is great er t han 0° C; fix low t em perat ure condit ion in t he Host 's locat ion. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 197 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Minor Alarms—Host Unit SFPs Ala r m : Opt ica l RX H igh BER Trap: fwuHstSERFOptRxBERFault Alarm Code: Definition: Threshold: Remedy: AC13 High bit error rat e ( BER) det ect ed by fiber opt ic receiver. 0.00001 Check/ repair opt ical overdrive condit ions ( Unit Information > View Optical Ports) . Ensure t hat fiber opt ic connect ions are clean. Check for kinks or sharp bends in t he fiber opt ic cable; replace fiber opt ic cable if unable t o correct any problem s found. Ala r m : Opt ica l Un de r D r ive Trap: fwuHstSERFOptUnderDriveFault Alarm Code: Definition: Threshold: Remedy: AC17 SFP opt ical receive input power below specificat ion. Threshold for I R is - 1 dBm , and for LR is - 27 dBm Check fiber opt ic cable for t oo m uch at t enuat ion and/ or dirt y connect ions. Check SFP t ype ( wavelengt h or I R/ LR) being used; replace t he SFP if it is t he wrong t ype. Minor Alarms—PRU/URU DARTs The following alarm s apply t o DARTs inst alled in a Prism Rem ot e Unit ( PRU) or in a URH Rem ot e Unit ( URU) . Ala r m : D ART Te m pe r a t u r e H igh Trap: fwuRmtDARTOverTempFault Alarm Code: Definition: Threshold: Remedy: AC99 DART t em perat ure above operat ing lim it . 85° C Check t he PRU/ URU fans. Check t he air flow around t he PRU/ URU. Ensure t hat t he PRU/ URU door is closed and t hat t he am bient t em perat ure is less t han 50° C. Check t hat t he heat sink m at erial on t he PRU/ URU DARTs has not been dam aged. I f t he alarm persist s, replace RF Module. Page 198 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Ala r m : D ART Te m pe r a t u r e Low Trap: fwuRmtDARTLowTempFault Alarm Code: Definition: Threshold: Remedy: AC100 DART t em perat ure below operat ing lim it . - 40° C Check am bient condit ions; fix low t em perat ure condit ions in t he DART's locat ion. Ala r m : D e la y Ou t Of Ra n ge Trap: fwuRmtRangingFault Alarm Code: Definition: Remedy: AC96 PRU/ URU delay set t ings out side t he valid range. Ent er forward and reverse delay values ( System Configuration > Configure Delay) wit hin t he displayed range. Minor Alarms—PRU/URU SeRF Modules The following alarm s apply t o SeRF m odules inst alled in a Prism Rem ot e Unit ( PRU) or in a URH Rem ot e Unit ( URU) . Ala r m : Fa n Ove r Spe e d Trap: fwuRmtFanOverSpeedFault Alarm Code: Definition: Remedy: AC76 Fans operat ing above expect ed RPM. I f alarm persist s, t hen replace t he Fan Module. Ala r m : Te m pe r a t u r e Low Trap: fwuRmtUnderTempFault Alarm Code: Definition: Threshold: Remedy: AC74 Tem perat ure below operat ing lim it . Minus 40° C Verify t hat am bient t em perat ure is great er t han - 40° C; fix low t em perat ure condit ion at t he locat ion of t he PRU/ URU. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 199 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Minor Alarms—PRU/URU SFPs The following alarm s apply t o SFPs inst alled in a Prism Rem ot e Unit ( PRU) or in a URH Rem ot e Unit ( URU) . Ala r m : Opt ica l RX H igh BER Trap: fwuRmtSERFOptRxBERFault Alarm Code: Definition: Threshold: Remedy: AC81 High bit error rat e ( BER) det ect ed by fiber opt ic receiver. 0.00001 Check/ repair opt ical overdrive condit ions ( Unit Information > View Optical Ports) . Ensure t hat fiber opt ic connect ions are clean. Check for kinks or sharp bends in t he fiber opt ic cable; replace fiber opt ic cable if unable t o correct any problem s found. Ala r m : Opt ica l Un de r D r ive Trap: fwuRmtSERFOptUnderDriveFault Alarm Code: Definition: Threshold: Remedy: AC85 SFP opt ical receive input power below specificat ion. Threshold for I R is - 1 dBm , and for LR is - 27 dBm Check fiber opt ic cable for t oo m uch at t enuat ion and/ or dirt y connect ions. Check SFP t ype ( wavelengt h or I R/ LR) being used; replace t he SFP if it is t he wrong t ype. Check for any m aj or alarm s ( Alarms > View Current Alarms) . Follow t he rem edies for t hose alarm s. Remedy: Minor Alarms—PRU or URU LPAs The following alarm s apply t o LPAs inst alled in a Prism Rem ot e Unit ( PRU) or URH Rem ot e Unit ( URU) . Ala r m : LPA Ove r Te m pe r a t u r e Trap: fwuRmtLPAHighTempFault Alarm Code: Definition: Threshold: Remedy: AC106 PRU/ URU LPA above operat ing lim it . 89° C Check am bient t em perat ure. Fix any t em perat ure problem s in t he area of t he PRU/ URU. Check t he PRU/ URU t em perat ure. Replace fan if it is fault y and correct any air flow problem s around t he PRU/ URU. Reset LPA. I f t he alarm persist s, replace t he RF Module. Page 200 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Alarm s Contact Alarms—Host System Card Ala r m : H ost M a j or Con t a ct Ala r m Ou t pu t Act ive Trap: fwuHstContactAlarmOutput1 Alarm Code: Definition: Remedy: AC41 User configurable Maj or Cont act Alarm Out put act ive. Check for any m aj or alarm s ( Alarms > View Current Alarms) . Follow t he rem edies for t hose alarm s. Ala r m : H ost M in or Con t a ct Ala r m Ou t pu t Act ive Trap: fwuHstContactAlarmOutput2 Alarm Code: Definition: Remedy: AC42 User configurable Minor Cont act Alarm Out put act ive. Check for any m inor alarm s ( Alarms > View Current Alarms) . Follow t he rem edies for t hose alarm s. Ala r m : H ost Con t a ct Ala r m I n pu t 1 Trap: fwuHstContactAlarmInput1 Alarm Code: Definition: Remedy: AC43 Host Cont act Alarm I nput # 1 act ive. Alarm level is user configurable. Check equipm ent connect ed t o Host Cont act Alarm I nput 1, or check cont act polarit y ( t hat is, Norm ally Open or Norm ally Closed) . Ala r m : H ost Con t a ct Ala r m I n pu t 2 Trap: fwuHstContactAlarmInput2 Alarm Code: Definition: Remedy: AC44 Host Cont act Alarm I nput # 2 act ive. Alarm level is user configurable. Check equipm ent connect ed t o Host Cont act Alarm I nput 2, or check cont act polarit y ( t hat is, Norm ally Open or Norm ally Closed) . Contact Alarms—Remote Unit The following alarm s can apply t o t he Prism Rem ot e Unit ( PRU) or t he URH Rem ot e Unit ( URU) . Ala r m : Con t a ct Ala r m I n pu t 1 Act ive Trap: fwuRemoteContactAlarmInput1 Alarm Code: Definition: Remedy: AC65 Rem ot e Unit ( PRU/ URU) Cont act Alarm I nput # 1 act ive. Check equipm ent connect ed t o Rem ot e Unit ( PRU/ URU) Cont act Alarm I nput 1, or check cont act polarit y ( i.e., Norm ally Open or Norm ally Closed) . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 201 © 2011 ADC Telecom m unicat ions, I nc. Troubleshoot ing Alarm s Ala r m : Con t a ct Ala r m I n pu t 2 Act ive Trap: fwuRemoteContactAlarmInput2 Alarm Code: Definition: Remedy: AC66 Rem ot e Unit ( PRU/ URU) Cont act Alarm I nput # 2 act ive. Check equipm ent connect ed t o Rem ot e Unit ( PRU/ URU) Cont act Alarm I nput 2, or check cont act polarit y ( i.e., Norm ally Open or Norm ally Closed) . Page 202 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 USERS Topics Page Underst anding FlexWave EMS User Account s ........................................................................... 204 Manage Users Page .............................................................................................................. 205 Add a New User ............................................................................................................. 205 Change a User’s Access Level ........................................................................................... 207 Change a User Password ................................................................................................. 208 Change Your Personal Password ............................................................................................. 210 Recovering a Password ......................................................................................................... 211 Delet e a User ...................................................................................................................... 212 This sect ion t ells you how t o m anage users, passwords, and user access t o a Prism syst em . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 203 © 2011 ADC Telecommunications, Inc. Underst anding FlexWave EMS User Account s UNDERSTANDING FLEXWAVE EMS USER ACCOUNTS The EMS provides securit y, which can be broadly classified as: • User Authentication, which defines t he way a user is ident ified prior t o being allowed t o log on t o t he EMS. User Aut hent icat ion ensures t hat only known users have access by providing a m et hod of ident ifying each user t hrough a user I D and password. • User Authorization, which involves m anaging t he user’s privileges in t he Prism net work m anagem ent infrast ruct ure. Aut horizat ion is based on t he concept of user access syst em configurat ion rest rict ions. There are t hree user- access account s t hat can be assigned by t he adm in: • adm in—t he default user account t hat has unrest rict ed access t o all EMS user account s and m anagem ent capabilit ies. To prot ect against unaut horized access t o t he Prism net work, t he user assigned t he adm in role should follow t he process described in “ Change Your Personal Password” on page 210 t o change t he password for t he adm in user account . • Net work Manager—has read and writ e access t o all syst em funct ions except user account m anagem ent . • Net work User—has read only perm issions int o t he syst em . There are also t wo default user- access account s for t he Rem ot e t hat cannot be delet ed or changed: • operat or—is only support ed on t he Craft int erface of a Rem ot e, and provides Read Only access t o m ost of t he Prism Rem ot e funct ions. However, t he operator login can be only t o change t he Rem ot e Capacit y set t ing ( see “ Set t he Capacit y for a New Rem ot e Unit RSI Board” on page 162) . • viewer—has Read Only right s for Prism and URH Rem ot es. FlexWave EMS prevent s a login in which t he user ent ers an invalid User I D or password. Table 24 list s t he default user account s and passwords. Table 24. Default User Account Device Access Port Access User Name Default Password Host Page 204 © 2011 ADC Telecommunications, Inc Remote admin adc123 Network and N/A Craft ports viewer viewer N/A Craft port operator operator N/A Craft port FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Users MANAGE USERS PAGE The Manage Users page allows you t o: • “ Add a New User” on page 205 • “ Change a User’s Access Level” on page 207 • “ Change a User Password” on page 208. Add a New User CAUTION! If Auto Complete (that is, remember username/password) is turned on in your web browser, when you add a new user, the browser automatically fills in Prism user names and passwords with the saved information. To avoid this, disable Auto Complete in your browser. To access t he Manage Users page, in t he Syst em Menu bar, click Users > Manage Users. I n t he Manage Users page, click Add New User. Do t he following in t he Add New User page: I n t he Name box, ent er a user nam e, which m ust st art wit h an alphabet ical charact er, cont ain at least 5 charact ers ( alphanum eric or underscore only) , and cont ain no spaces. I n t he Password box, ent er a password specific t o t his user. The Password m ust cont ain at least 6 alphanum eric or special charact ers, and cannot be em pt y or cont ain spaces. I n t he Confirm Password box, ent er t he exact sam e password as you ent ered in t he Password box. I n t he Access Level m enu, select t he access level for t his user. See “ Underst anding FlexWave EMS User Account s” on page 204. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 205 © 2011 ADC Telecom m unicat ions, I nc. Manage Users Page Click Add. The following m essage displays, list ing t he new user by Name. Addit ionally, t he Add New User fields are cleared so you can add ot her users as needed. I n t he Syst em Menu bar, click Users > Manage Users t o see an updat ed list of users. Page 206 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Users Change a User’s Access Level I n t he Syst em Menu bar, click Users > Manage Users t o see a list of users. To change a user’s access, select t he user in t he Select colum n, which act ivat es t he operat ional but t ons. Click Change Access. Verify t hat t he nam e list ed for Selected User is t he user whose access level you want t o change. I n t he Change Access Level page, use t he Access Level m enu t o change t he access level for t his user. For furt her inform at ion on access levels, see “ Underst anding FlexWave EMS User Account s” on page 204. Click Change Access. The Access Level for is changed successfully m essage displays. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 207 © 2011 ADC Telecom m unicat ions, I nc. Manage Users Page I n t he Syst em Menu bar, click Users > Manage Users t o see an updat ed list of users. At t his t im e t he operat ional but t ons, wit h t he except ion of Add New User and Refresh, will be disabled, as no user is select ed. Change a User Password NOTE: Only the admin user or a user with the Network Manager access level can change the password of another user. I n t he Syst em Menu bar, click Users > Manage Users t o see a list of users. To change a user’s password, select t he user in t he Select colum n, which act ivat es t he operat ional but t ons. Page 208 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Users Click Change Password. I n t he Change Password page, do t he following: Verify t hat t he nam e list ed for Selected User is for t he user whose password you want t o change. I n t he New Password box, ent er a new password for t his user. The Password m ust cont ain at least 6 alphanum eric or special charact ers, and cannot be em pt y or cont ain spaces. I n t he Confirm Password box, ent er t he exact sam e password as you ent ered in t he New Password box. Click Change Password. The Password changed successfully m essage displays. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 209 © 2011 ADC Telecom m unicat ions, I nc. Change Your Personal Password CHANGE YOUR PERSONAL PASSWORD I n t he Syst em Menu bar, click Users > Change Password. I n t he Change Password page, do t he following: I n t he Old Password box, ent er your exist ing password. I n t he New Password box, ent er a new password for t his user. The Password m ust cont ain at least 6 alphanum eric or special charact ers, and cannot be em pt y or cont ain spaces. I n t he Confirm Password box, ent er t he exact sam e password as you ent ered in t he New Password box. Click Change Password. The Password for has been changed m essage displays. Page 210 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Users RECOVERING A PASSWORD I f a user changes his or her password and t hen forget s t he new password, t he adm in user needs t o recreat e an account for t he user. I f t he password is changed and t hen forgot t en for t he adm in user, t he adm in should cont act ADC for assist ance. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 211 © 2011 ADC Telecom m unicat ions, I nc. Delet e a User DELETE A USER I n t he Syst em Menu bar, click Users > Manage Users t o see a list of users. Select t he user whose account is t o be delet ed in t he Select colum n, which act ivat es t he operat ional but t ons. Click Delete. I n t he confirm at ion dialog, which ident ifies t he user being delet ed, click OK. The User deleted successfully m essage displays and t he Users t able is updat ed in t he Manage Users page. Page 212 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 UPGRADING THE SYSTEM AND UNITS Topics Page Upload t he Upgrade Files ...................................................................................................... 214 Updat ing a Prism Syst em ...................................................................................................... 216 Com m it t he Upgrade ............................................................................................................ 219 Abort an Updat e .................................................................................................................. 220 Updat ing I ndividual Unit s ...................................................................................................... 221 Upgrading a Prism syst em or a unit wit hin a Prism syst em is a t hree- st ep process, in which you do t he following: Upload t he upgrade file. Use t he upgrade file t o updat e t he syst em or unit . Com m it t he updat e. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 213 © 2011 ADC Telecommunications, Inc. Upload t he Upgrade Files U PLOAD THE U PGRADE F ILES Use t he Upload page t o t ransfer t he required upgrade files from a com put er or lapt op t o your Prism syst em or unit . Each soft ware upgrade requires t he following files t o go from one version t o t he next : • upgrade.x-y.tar.gz.md5 • upgrade.x-y.tar.gz where • x ident ifies t he version from which t he unit / syst em is being upgraded • y ident ifies t he version t o which t he unit / syst em is being upgraded. NOTE: Each upgrade file set is designed to upgrade a specific EMS release, which may be updating the EMS GUI or unit firmware, or both. If you try to apply upgrade files to a system/unit that is not running the EMS release for which the upgrade files are designed, the update will abort when it runs its version check. Do t he following t o upload t he required upgrade files: Cont act ADC t o obt ain t he appropriat e upgrade files ( see “ Appendix C: Cont act ing ADC/ TE Connect ivit y” on page 297) . Verify t hat t here is sufficient space on t he disk drive t o accom m odat e t he upgrade files t hat you need t o upload. Save t he upgrade files t o your com put er. To access t he Upload page, in t he Syst em Menu bar, click Upgrades > Upload. Click Browse. I n t he Choose File dialog, navigat e t o where t he upgrade *.tar.gz and *.tar.gz.md5 files are st ored. Page 214 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Upgrading t he Syst em and Unit s Select t he *.tar.gz file, and t hen click Open. The Choose File dialog closes and t he nam e of t he select ed file displays in t he Upgrades > Upload page File box. Click Upload. Wait for t he File has been uploaded m essage t o display. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 215 © 2011 ADC Telecom m unicat ions, I nc. Updat ing a Prism Syst em I n t he Upload page, Click Browse. 1 0 I n t he Choose File dialog, navigat e t o where t he upgrade *.tar.gz and *.tar.gz.md5 files are st ored. 1 1 Select t he *.tar.gz.md5 upgrade file, and t hen click Open. 1 2 The Choose File dialog closes and t he nam e of t he select ed file displays in t he Upgrades > Upload page File box. 1 3 Click Upload. Wait for t he File has been uploaded m essage t o display. UPDATING A PRISM SYSTEM Follow t his procedure t o updat e a FlexWave Prism syst em , or an individual unit wit hin a FlexWave Prism syst em . CAUTION! Do not make any configuration changes during an update. CAUTION! This procedure takes the system selected for update temporarily offline (see estimates in Table 25). Perform this procedure during normal maintenance window. Table 25. Estimated Time a System is Offline During an Upgrade System Configuration NOTE: Approximate Time Offline (Minutes) 1 Host + 1 Remote Unit 7 - 11 1 Host + 2 Remote Units 10 - 18 1 Host + 3 Remote Units 15 - 27 1 Host + 4 Remote Units 21 - 37 1 Host + 5 Remote Units 28 - 48 1 Host + 6 Remote Units 37 - 61 1 Host + 7 Remote Units 48 - 76 1 Host + 8 Remote Units 60 - 92 To update an individual unit, see “Updating Individual Units” on page 221. Do t he following t o updat e an FlexWave Prism syst em : Access t he Soft ware/ Firm ware report t o verify current syst em soft ware. I n t he Syst em Menu bar, click System Information > Get Information. The System Information > Get Information page opens. I n t he Type list , select Software/Firmware. ( This is t he default set t ing.) Page 216 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Upgrading t he Syst em and Unit s The Software/Firmware t able provides t he following inform at ion: • Module Type—t ype of unit ( Host , PRU, or URU) . • Name—user- assigned nam e for t he unit . • Unit Id—ident ifies t he unit wit hin t he syst em ( see “ Unit I dent ificat ion” on page 43) . • Version—version of inst alled soft ware/ firm ware. • Upgrade Status—t he following st at es can be seen. However, wit h t he except ion of Normal operation and Upgraded, t he st at es occur very quickly during t he corresponding act ion and are rarely viewed. – Normal operation – Upgrading – Upgrading reboot – Committing – Aborting – Recovering – Upgraded – NA ( analog unit s only) . Follow t he st eps in “ Upload t he Upgrade Files” on page 214 t o upload t he required upgrade files. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 217 © 2011 ADC Telecom m unicat ions, I nc. Updat ing a Prism Syst em Updat e t he Host and t he Rem ot e Unit ( s) : I n t he Syst em Menu bar, click Upgrades > Update Units. I n t he Update Units page, you are not ified t hat t he file t hat you uploaded in “ Upload t he Upgrade Files” on page 214 is ready for use. I f an upgrade file is not list ed, repeat t he st eps in “ Upload t he Upgrade Files” on page 214. NOTE: I n t he Select Unit Type list , select Host+DRU+PRU+URU. The IFEU + RAU option pertains to an InterReach Spectrum system only and is not applicable to a Prism system. As such, do not select the IFEU + RAU option. Click Update Now. An inform at ion m essage t hat t he updat e has st art ed appears. Wit hin four m inut es, t he EMS logs you off and t erm inat es t he EMS session. Page 218 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Upgrading t he Syst em and Unit s CAUTION! At this point, the system goes offline for the approximate time listed in Table 25 on page 216. Wait approxim at ely four m inut es, and t hen log back in t o t he EMS t o com plet e t his procedure. Com plet e St ep 1 on page 216 t o verify t he st at us of t he Host / Rem ot e Unit ( s) updat es. COMMIT THE UPGRADE NOTE: If you need to abort an update, go to“Abort an Update” on page 220. Com plet e t he st eps in “ Updat ing a Prism Syst em ” on page 216. I n t he Syst em Menu bar, click Upgrades > Commit. I n t he Upgrades > Commit page, click Commit. I n t he confirm at ion window, click OK. The syst em inform s you when t he com m it operat ion has com plet ed. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 219 © 2011 ADC Telecom m unicat ions, I nc. Abort an Updat e ABORT AN UPDATE An upgrade can be abort ed, if necessary. NOTE: If you want to commit an update, go to “Commit the Upgrade” on page 219. To access t he Upgrades Abort page, in t he Syst em Menu bar, click Upgrades > Abort. Click Abort. I n t he confirm at ion window, click OK. The syst em inform s you when t he abort operat ion has com plet ed. Page 220 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Upgrading t he Syst em and Unit s UPDATING INDIVIDUAL UNITS Only perform a unit updat e on a unit when t he unit is being added t o t he syst em as a new or replacem ent unit , and t he new unit requires a firm ware updat e t o m at ch t he firm ware version of t he ot her unit s wit hin t he syst em . CAUTION! If this procedure is performed on a Host Unit, the Host is taken offline (see estimates in Table 25 on page 216). Perform this procedure during normal maintenance time. CAUTION! Do not make any configuration changes during an update. NOTE: To update a Prism system, follow the steps in “Updating a Prism System” on page 216. Com plet e t he following st eps t o updat e an individual Host , PRU, or URU: Access t he Soft ware/ Firm ware report t o verify current syst em soft ware. I n t he Syst em Menu bar, click System Information > Get Information. The System Information > Get Information page opens. I n t he Type list , select Software/Firmware. ( This is t he default set t ing.) For inform at ion on t he Software/Firmware t able, see “ Updat ing a Prism Syst em ” . Follow t he st eps in “ Upload t he Upgrade Files” on page 214 t o upload t he required updat e files. I n t he Syst em Tree, click on t he icon of t he unit t hat you want t o updat e. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 221 © 2011 ADC Telecom m unicat ions, I nc. Updat ing I ndividual Unit s I n t he Unit Menu bar, click Unit Upgrades, Upgrade. NOTE: If you have not uploaded the required update files, the following page opens, and the Update button is disabled. You cannot continue until the correct update files have been loaded. Click Update. Wit hin four m inut es, t he EMS logs you off and t erm inat es t he EMS session. CAUTION! At this point, the system goes offline for the approximate time listed in Table 25 on page 216. Wait approxim at ely four m inut es, and t hen log back in t o t he EMS t o com plet e t his procedure. Com plet e St ep 1 on page 216 t o verify t he st at us of t he updat e. Do not m ove forward t o t he next st ep unt il t he UpGrade Status in t he Soft ware/ Firm ware t able is list ed as Upgraded. Page 222 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Upgrading t he Syst em and Unit s Com m it t he updat e t o t he unit . ( I f you need t o abort an updat e, go t o “ Abort an Updat e” on page 220.) I n t he Syst em Menu bar, click Upgrades > Commit. I n t he Upgrades > Commit page, click Commit. I n t he confirm at ion window, click OK. The syst em inform s you when t he com m it operat ion has com plet ed. Com plet e St ep 1 on page 216 t o verify t he st at us of t he updat e. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 223 © 2011 ADC Telecom m unicat ions, I nc. Updat ing I ndividual Unit s I nt ent ionally Blank Page Page 224 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 SPECIAL FEATURES Topics Page Run Script ........................................................................................................................... 226 Run Com m and ..................................................................................................................... 226 Configure Feat ure ................................................................................................................ 227 This sect ion describes special feat ures of t he Prism EMS. NOTE: Some of the features in this section are for use by ADC only. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 225 © 2011 ADC Telecommunications, Inc. Run Script R UN S CRIPT The Run Script page, accessed via Special Features > Run Script, is not applicable t o a Prism syst em and should not be used. R UN C OMMAND The Run Command page, accessed via Special Features > Run Command, is not applicable t o a Prism syst em and should not be used. Page 226 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Special Feat ures C ONFIGURE F EATURE CAUTION! This procedure requires a system reboot. The system configuration is stored on the Host. Rebooting the Host therefore results in a loss of RF for the Host and connected Remote Units until the Host comes back up. Depending on the system configuration, it can take 5 to 20 minutes before management communication is restored. CAUTION! Host configuration will not persist across a Configure Feature Reboot—all settings will revert to factory default. You will need to reconfigure the Prism system after the system reboots. CAUTION! The current EMS session will close and you will need to log back in to the EMS after the Host reboot has completed. Docum ent all configurat ion dat a, as set t ings will have t o be re- ent ered. To record t he current configurat ion: Follow t he procedures in “ Viewing t he All Report ” on page 112 t o access t he syst em configurat ion report s. Follow t he procedures in “ Downloading a Report ” on page 113 t o download t he syst em configurat ion report s t o a hard drive. To access t he Configure Feature page, in t he Syst em Menu bar, click Special Features > Configure Feature. I n t he Feature box, ent er t he code for t he feat ure. I n t he Password box, ent er t he password t hat enables t he feat ure. Click Apply. I n t he confirm at ion dialog, click OK. Log back in t o t he EMS once t he login window displays. Follow t he st eps in “ I nit ial FlexWave Prism Syst em Set up” on page 55 t o reconfigure t he Prism syst em , using t he set t ings recorded in St ep 1 on page 227. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 227 © 2011 ADC Telecom m unicat ions, I nc. Configure Feat ure I nt ent ionally Blank Page Page 228 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 USING AN SNMP INTERFACE Topics Page SNMP Overview ................................................................................................................... 230 Working wit h Prism MI B Files................................................................................................. 231 Accessing Prism MI Bs...................................................................................................... 233 Syst em Dat e and Tim e MI B Form at ................................................................................... 234 Band Types ................................................................................................................... 235 Prism MI B Obj ect s................................................................................................................ 236 Param et ers in ADC- FLEXWAVE- URH- MI B ........................................................................... 237 Syst em - Level Param et ers .......................................................................................... 237 Host Unit Param et ers ................................................................................................ 239 Host Param et ers.................................................................................................. 239 Host SeRF Card Param et ers .................................................................................. 240 Host SeRF Opt ics Param et ers ................................................................................ 243 Host SeRF ENET Swit ch Param et ers ....................................................................... 245 Host SeRF FPGA Param et ers ................................................................................. 247 Host List of Rem ot es Param et ers ........................................................................... 247 Host DART Module Param et ers .............................................................................. 248 Host Syst em Card Param et ers ............................................................................... 252 Rem ot e Unit Param et ers ............................................................................................ 254 Rem ot e Param et ers ............................................................................................. 254 Prism Rem ot e Syst em Card................................................................................... 256 Prism Rem ot e SeRF General.................................................................................. 257 Prism Rem ot e SeRF Opt ics.................................................................................... 260 Prism Rem ot e SeRF ENET Swit ch ........................................................................... 262 Prism Rem ot e SeRF FPGA ..................................................................................... 264 Prism Rem ot e DART............................................................................................. 264 Prism Rem ot e LPA ............................................................................................... 270 Prism Rem ot e Power Det ect or ............................................................................... 272 Prism Rem ot e LNA/ Duplexer ................................................................................. 273 Prism Rem ot e RDI Card ........................................................................................ 274 Prism Rem ot e RSI Card ........................................................................................ 275 Com m on Managed Obj ect s ......................................................................................... 276 Prism DART Mapping ............................................................................................ 276 Schedule Syst em Link Test ................................................................................... 278 SNMP Set t ings .................................................................................................... 279 Regist er SNMP Trap Manager ................................................................................ 280 Geographic Locat ions ................................................................................................ 281 GEO Obj ect s ....................................................................................................... 281 GEO Table Obj ect s............................................................................................... 282 Managed Obj ect s for Traps ......................................................................................... 283 Prism I nput Cont act Alarm Managem ent Table......................................................... 283 Syst em Act ive Alarm Table ................................................................................... 284 Alarm Managem ent Table ..................................................................................... 287 Alarm Enable Table .............................................................................................. 288 St at ic Alarm s Table.............................................................................................. 288 Working wit h SNMP Traps ..................................................................................................... 290 View t he Traps ............................................................................................................... 290 Managing Traps.............................................................................................................. 291 Dat e and Tim e St am ps in Traps ........................................................................................ 292 Variable Bindings............................................................................................................ 293 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 229 © 2011 ADC Telecommunications, Inc. SNMP Overview SNMP OVERVIEW SNMP ( Sim ple Net work Managem ent Prot ocol) is an int ernat ional st andard for rem ot e cont rol of online devices. A t ypical scenario involves t he devices being cont rolled, rem ot e com put ers ( called m anagers) t hat can cont rol t hem , a net work connect ion, and SNMP soft ware. The SNMP soft ware includes SNMP m anager soft ware on cont rolling com put ers, SNMP agent soft ware on m anaged devices, and one or m ore MI Bs used by t he SNMP m anagers for each cont rolled device. I n som e cases, SNMP proxy agent soft ware is run on an int erm ediat e device t o access a m anaged device t hat would not ot herwise be direct ly accessible. The Prism syst em SNMP int erface, shown schem at ically in Figure 27 allows a rem ot e user using an SNMP m anager t o access t he sam e dat abase as accessed by t he st andard EMS int erface. IP Web Windows 2000 or Windows XP computer running Internet Explorer or Mozilla and/or SNMP Manager IP TRAP GET/SET Network port EMS INTERNAL Database Host Unit Figure 27. SNMP and a Prism System Page 230 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface WORKING WITH PRISM MIB FILES NOTE: Examples shown in this chapter use a browser from AdventNet or iReasoning. Procedural details may vary with another browser, but the basic steps are the same. NOTE: In the Prism system, the database accessed through the SNMP interface is the same database as used by the EMS graphical user interface. There is therefore a similarity between MIB objects and the parameters displayed in the EMS Web pages. Figure 28 shows t he feat ures of a t ypical MI B browser. Figure 28. Typical MIB Browser As m ent ioned earlier, a MI B is a dat abase specificat ion cont aining definit ions and organizat ion of inform at ion. The dat abase consist s of t ables of obj ect s used t o exchange inform at ion bet ween a m anager and agent . Dat abase inform at ion is exchanged using t he following basic operat ions: • GET—obt ains an obj ect value from t he dat abase. • SET—set s t he value of an obj ect in t he dat abase. • GET-NEXT—get s t he next it em in t he dat abase, be it t he next t ype of obj ect or t he next obj ect of t he specified t ype. This is especially useful for discovering t he presence of ent ries in dynam ic t ables. • GET-BULK—request s m ult iple it em s in one m essage. • TRAP/NOTIFICATION—sends an alarm in which a response can be sent by a m anager t o an agent confirm ing receipt of t he alarm . FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 231 © 2011 ADC Telecom m unicat ions, I nc. Working wit h Prism MI B Files I n a m anager browser, a MI B looks like t he EMS Syst em Tree’s hierarchy of folders and files, as shown in Figure 29. Figure 29. Prism MIB Tree MI B it em s are arranged in a hierarchy of groups, like a hierarchy of folders. Known OI Ds specify scalars ( obj ect s) . MI B obj ect s are arranged in groups and t ables. To be specified com plet ely, t able ent ries require one or m ore row indices. Each set of obj ect s ( wit hin a single folder) represent s one such group or t able. An obj ect m arked wit h a key sym bol indicat es t hat view is t he key value for t hat t able. The Prism MI B is defined by t hree files: • ADC-FWU-URH-TC-MIB.mib • ADC-FWU-IRS-TC-MIB.mib • ADC-FLEXWAVE-URH.mib The MI B can be found on t he SeRF I I card in t he Host in /usr/local/fwu/mibs. “ Prism MI B Obj ect s” on page 236 list s obj ect s t hat m ay be accessed for GET/ SET operat ions and t raps/ not ificat ions t hat are sent t o SNMP m anagers regist ered t o receive t hem whenever t he respect ive fault condit ion occurs. NOTE: TRAPS/NOTIFICATIONS are listed with the corresponding EMS alarm in “Troubleshooting Alarms” on page 185. Page 232 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Accessing Prism MIBs The Prism Agent MI B can be accessed using any SNMP m anager wit h an act ive net work connect ion. The I P address of t he Host m ust be known and ent ered in t he MI B browser. On t he m anager com put er, open t he MI B Browser. Load t he MI B files in t he following order: ADC-FWU-URH-TC-MIB.mib ADC-FWU-IRS-TC-MIB.mib ADC-FLEXWAVE-URH.mib Ent er t he I P address of t he Host of t he Prism syst em in t he t ext box provided next t o Host. Ent er t he Port number as 161. NOTE: If you are upgrading from a previous release, note the change in the SNMP Port number. In previous releases, the SNMP Port number was 8001. It is now 161. Ent er t he Read Community as public and Write Community as private. Set Timeout t o 15 seconds. For SNMP version v2c and v3, set Maximum Repetitions t o 10 or less. To see an overview t he MI B cont ent , expand t he MI B t ree, as shown below. FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 233 © 2011 ADC Telecom m unicat ions, I nc. Working wit h Prism MI B Files System Date and Time MIB Format fwuHstSystemDateandTime allows you t o set t he syst em dat e and t im e, where t he input is as follows: YYYY-MM-DD,HH:MM:SS.D (24-Hour Time Format) where fields are required ( none are opt ional) and indicat e t he following in 24- Hour t im e form at . • YYYY—Year • MM—Mont h • DD—dat e • HH—Hour • MM—Min ut e • SS—Seconds You can input t he m ont h, dat e, hour, m inut es, seconds, and deci seconds as a single digit or as a double digit ( t hat is, prefixed wit h 0) . The support ed dat e and 2037-12-31,23:59:59. t im e range is from 1970-01-01,00:00:00 to The out put for m ont h, dat e, hour, m inut es, and seconds will always be in double digit form at ( prefixed wit h 0) . The out put for deci seconds will always be single digit . For exam ple, t he out put of 2009-01-02,03:04:05 can be result ant from eit her of t he following input s: • I nput 1—2009-01-02,03:04:05 • I nput 2—2009-1-2,3:4:5 Page 234 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Band Types Table 26 list s t he band t ypes for Host RF DARTs, and Table 27 on page 236 list s t he band t ypes for Rem ot e I F DARTs. Table 26. MIB Band Types—Host RF DARTS MID Value Band Type -1 undefined Classic850 Classic1900 ClassicSMR800 ClassicSMR900 ClassicAws2100 Classic1800 200 SingleSuperPcs1900 201 SingleSuper1800 202 SingleSuperUmts2100 203 SingleSuperAws2100 SuperPcs1900 10 SuperUmts2100 11 SuperAws2100 12 SuperEgsm900 13 SuperLowerAbc700 14 SuperUpperC700 205 SingleSuperLowerAbc700 206 SingleSuperUpperC700 FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 235 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Table 27. MIB Band Types—Remote IF DARTS MID Value Band Type 15 SuperIf850 16 SuperIfPcs1900 17 SuperIfSmr800 18 SuperIfSmr900 19 SuperIf1800 21 SuperIfAws2100 23 SuperIfPath1LowerAbc700 24 SuperIfPath1UpperC700 25 SuperIfPath2LowerAbc700 26 SuperIfPath2UpperC700 207 SingleSuperIf850 208 SingleSuperIfPcs1900 209 SingleSuperIfSmr800 210 SingleSuperIfSmr900 211 SingleSuperIf1800 213 SingleSuperIfAws2100 215 SingleSuperIfPath1LowerAbc700 216 SingleSuperIfPath1UpperC700 217 SingleSuperIfPath2LowerAbc700 218 SingleSuperIfPath2UpperC700 PRISM MIB OBJECTS Obj ect s in t he Prism Agent MI B divide int o t wo t ypes: GET/ SET obj ect s and Trap/ Not ificat ion obj ect s. For each GET and SET obj ect , t here is an SNMP synt ax, which is a range of values defined in t he MI B file. These values are what can be ent ered in a SET com m and and ret urned in a GET com m and. The following sect ions list all MI B obj ect s wit hin t he Prism Agent MI B. Obj ect s t hat are available for SET com m ands are also available for GET com m ands. Page 236 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Parameters in ADC-FLEXWAVE-URH-MIB System-Level Parameters Syst e m D a t e a n d Tim e SNMP MIB: Description: Values: fwuHstSystemDateAndTime The dat e and t im e set t ings on t he syst em 1970- 01- 01,00: 00: 00 t o 2037- 12- 31,23: 59: 59; see “ Syst em Dat e and Tim e MI B Form at ” on page 234 Default: Syst em t im e Syntax: Dat eAndTim e Access Level: Oct et St ring Syst e m Ala r m Ack n ow le dge SNMP MIB: Description: Values: fwuSystemAlarmAck Acknowledges all or individual alarm s 0 = Acknowledge all alarm s Great er t hen 0, I d of t he alarm t o be acknowledged Syntax: I nt eger32 Access Level: Read- Writ e Syst e m Ala r m Le ve l SNMP MIB: Description: Syntax: Access Level: fwuAlarmLevel Alarm level of syst em Alarm Type Read- Writ e Syst e m Te st On Pow e r Up SNMP MIB: Description: Values: fwuPwrUpLinkTest Syst em / Link Test on Power Up ( Link Test ) 1 = Enable 0 = Disable Default: Syntax: Unsigned32 Access Level: Read- Writ e FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 237 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s D ART Ba n d Type for Syst e m Te st Use r Com m a nde d SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuUserCommLinkTestDartBandType Band t ype ( t he RF DART t ype) of select ed unit s See “ Band Types” on page 235. BandType Read- Writ e D ART I D for Syst e m Te st Use r Com m a n de d SNMP MIB: Description: Values: Syntax: Access Level: fwuUserCommLinkTestDartId I d of a part icular DART 1 - 8 I nt eger32 Read- Writ e Syst e m Ala r m St a t u s Su m m a r y SNMP MIB: Description: Syntax: Access Level: fwuSystemAlarmStatusSummary Alarm St at us Sum m ary for ent ire syst em Alarm Type Read Only Cle a r Syst e m Con figu r a t ion SNMP MIB: Description: fwuClearSysConfig Changing t he value from 0 t o 1 clears t he set t ing for t he ent ire set t ings on t he syst em Values: 0 = Disable 1= Enable Default: Syntax: I nt eger32 Access Level: Read- Writ e La st Run Tim e of Syst e m / Lin k Te st SNMP MIB: Description: Syntax: Access Level: fwuLinkTestLastRunTime Tim e when t he Syst em / Link t est was last run Dat eAndTim e Read Only Page 238 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Host Unit Parameters Host Parameters H ost N u m be r SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuHstNumber Num ber enum erat ing a Host A num ber great er t han 0 I nt eger32 Read Only H ost N a m e SNMP MIB: Description: Values: fwuHstName User defined nam e of t he Host Alphanum eric Charact ers. Except as first charact er, t he underscore ( _) charact er is allowed. Must be 5 t o 40 charact ers in lengt h, wit h no spaces. Default: Unknown_Host Nam e Syntax: Display St ring Access Level: Read- Writ e H ost Un it Re se t SNMP MIB: Description: Values: fwuHstUnitReset Reset s t he Host SeRF card when t he value is changed from 0 t o 1 0= norm al 1 = reset Default: Syntax: I nt eger Access Level: Read- Writ e H ost Ba ck Pla ne Re vision SNMP MIB: Description: fwuHstBackPlaneRev Provides t he back plane revision of t he Host ( Three pin Version Num ber of t he Chassis back plane) Values: SI ZE ( 1…40) Syntax: Oct al St ring Access Level: Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 239 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s H ost Ala r m St a t u s Sum m a r y SNMP MIB: Description: Syntax: Access Level: fwuHstAlarmStatusSummary Alarm St at us Sum m ary for Host ALARM- TYPE Read Only Te m pe r a t u r e M e a su r e m e n t SNMP MIB: Description: Values: Syntax: Access Level: fwuHstTempMeas Host syst em t em perat ure value in Celsius SI ZE ( 1…8) Oct al St ring Read Only Lin k in g M ode SNMP MIB: Access Level: Values: Default: Syntax: Access Level: fwuHstLinkingMode The DART Linking m ode on t he Syst em 2 = Manual I nt eger Read- Writ e Host SeRF Card Parameters Lin u x Ke r n e l Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstSERFLinuxKernelVer Linux Kernel Version of t he Host syst em Display St ring Read Only Lin u x Boot Loa de r Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstSERFLinuxBootLoaderVer Version Num ber of t he second st age boot loader Display St ring Read Only Com pa ct Fla sh SW Ve r sion SNMP MIB: Description: Values: fwuHstSERFCompactFlashSWVer Com pact Flash Version of t he Host syst em Form at of: aa.bb.cc.dd where each of aa, bb, cc, dd m ust be bet ween 00 and 99 Syntax: Display St ring Access Level: Read Only Page 240 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface PPC H W M on it or SW Ve r sion SNMP MIB: Description: fwuHstSERFPPCHWMonSWVer Soft ware Version of t he hardware Monit or process running on t he Host Syntax: Display St ring Access Level: Read Only PPC Applica t ion M on it or SW Ve r sion SNMP MIB: Description: fwuHstSERFPPCAPPMonSWVer Soft ware Version of t he Applicat ion Monit or process running on t he Host Syntax: Display St ring Access Level: Read Only SN M P Age n t SW Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstSERFPPCSNMPAgentSWVer Soft ware Version of t he HTTP/ SNMP agent running on Host Display St ring Read Only PPC M a t e M on it or SW Ve r sion SNMP MIB: Description: fwuHstSERFPPCMATEMonSWVer Soft ware Version of t he Mat e Monit or process running on t he Host Unit Syntax: Display St ring Access Level: Read Only PPC EN ET M on it or SW Ve r sion SNMP MIB: Description: fwuHstSERFPPCENETMonSWVer Soft ware Version of t he Et hernet Monit or process running on t he Host Unit Syntax: Display St ring Access Level: Read Only PPC FPGA M on it or SW Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstSERFPPCFPGAMonSWVer Version of FPGA Loaded on SeRF Display St ring Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 241 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Lin u x Fir st St a ge Boot Loa de r Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstSERFLinuxBootLoaderVer Boot Loader1 Version of t he Host syst em Display St ring Read Only Se RF FPGA Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstSERFFPGAVer Version of FPGA Loaded on SeRF Display St ring Read Only RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuHstSERFRIADCPartNumber Host SeRF I nvent ory - ADC Part Num ber Display St ring Read Only RI Se r ia l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuHstSERFRISerialNumber Host SeRF I nvent ory - Serial Num ber Display St ring Read Only RI D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuHstSERFRIDateCode Host SeRF I nvent ory - Dat e Code Display St ring Read Only Se RF RI H a r dw a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstSERFRIHWVer Host SeRF I nvent ory - Hardware Version Oct al St ring Read Only Se RF RI H a r dw a r e Ge n e r a t ion SNMP MIB: Description: Values: fwuHstSERFRIHWGen Host SeRF Hardware Generat ion 0 = First Generat ion 1 = Second Generat ion Syntax: I nt eger Access Level: Read Only Page 242 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface pTh r e a d Soft w a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwupThreadSoftwareVersion The version num ber of pThread process DisplaySt ring Read Only Su ba ge n t Soft w a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuSubagentSwVersion The version num ber of t he subagent DisplaySt ring Read Only W e b Se r ve r Soft w a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuWebServerSwVersion The version num ber of web server DisplaySt ring Read Only Host SeRF Optics Parameters SFP N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuHstSERFOptSFPNumber SFP Num bers used as I ndex for Opt ical Port s 1 - 8 I nt eger32 Read Only SFP N a m e SNMP MIB: Description: Values: fwuHstSERFOptSFPName User defined SFP nam e - Opt ical Port Nam e Alphanum eric Charact ers. Except as first charact er, t he underscore ( _) charact er is allowed. Must be bet ween 5 and 32 charact ers in lengt h, wit h no spaces. Default: UnknownSFPNam e Syntax: Display St ring Access Level: Read- Writ e SFP Type SNMP MIB: Description: Syntax: Access Level: fwuHstSERFOptSFPType SFP Type - Opt ical Port Type Opt icsType Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 243 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s SFP Tr a n sm ission Color SNMP MIB: Description: Syntax: Access Level: fwuHstSERFOptSFPTxColor SFP wavelengt h in nanom et er ( nm ) I nt eger32 Read Only FW D La u n ch Pow e r SNMP MIB: Description: Syntax: Access Level: fwuHstSERFOptFwdLaunchPowerMeas Value of Host Transm it m easured opt ical power in dBm DisplaySt ring Read Only REV Re ce ive Pow e r SNMP MIB: Description: Syntax: Access Level: fwuHstSERFOptRevLaunchPowerMeas Value of Host Receive m easured opt ical power in dBm DisplaySt ring Read Only Mate Nam e SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuHstSERFOptMateName Nam e of Host Mat es I nherit s t he valid values from Host Nam e NA DisplaySt ring Read Only Mate I D SNMP MIB: Description: Values: Syntax: Access Level: fwuHstSERFOptMateId I D ( num erical) of com panion Rem ot e Unit See “ Unit I dent ificat ion” on page 43 NodeAddr1 Read Only M a t e SFP I D SNMP MIB: Description: Values: Syntax: Access Level: fwuHstSERFOptMateSfpId Slot I D of t he SFP used at rem ot e end 1 - 8 I nt eger32 Read Only Page 244 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Host SeRF ENET Switch Parameters Et h e r n e t Por t N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuHstSERFEthPortNumber An ident ifier for each Et hernet port 1…12 Unsigned32 Read Only Et h e r n e t Por t Type SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortType An ident ifier for t he t ype of Et hernet port Enet Type Read Only H ost SFP I D SNMP MIB: Description: Values: Syntax: Access Level: fwuHstSERFEthPortSFPId I dent ifier of SFP t o which t he Et hernet port connect s 1…8 I nt eger32 Read Only Rx - byt e s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortRxBytes Receive byt e count er Count er64 Read Only Rx - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortRxPkts Receive packet count er Count er64 Read Only Rx - fsc- e r r or s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortRxFcsErrors Receive FCS error count er Count er64 Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 245 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Re ce ive - m u lt ica st - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortRxMulticastPkts Receive m ult icast packet count er Count er64 Read Only Re ce ive - br oa dca st - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortRxBroadcastPkts Receive broadcast packet count er Count er64 Read Only Rx - fr a gm e n t e d- fr a m e s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortRxFragmtdFrames Receive fragm ent s count er Count er64 Read Only Rx - j a bbe r - fr a m e s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortRxJabbersFrames Receive j abber count er Count er64 Read Only Tx - byt e - cou n t e r SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortTxByteCounter Transm it byt e count er Count er64 Read Only Tx - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortTxPkts Transm it packet count er Count er64 Read Only Tx - m u lt ica st - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortTxMulticastPkts Transm it m ult icast packet count er Count er64 Read Only Page 246 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Tx - br oa dca st - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuHstSERFEthPortTxBroadcastPkts Transm it broadcast packet count er Count er64 Read Only Host SeRF FPGA Parameters St a t u s SNMP MIB: Description: Values: fwuHstSERFFPGAStatus Gives t he st at us if FPGA on SeRF Card 0 = PPC can t alk t o FPGA 1 = PPC cannot t alk t o FPGA Default: Syntax: I nt eger Access Level: Read Only Host List of Remotes Parameters M on it or I n de x SNMP MIB: Description: Syntax: Access Level: fwuHMmonIndex I ndex of t he Host m at e m onit or t able I nt eger32 Read Only Re m ot e I D SNMP MIB: Description: Values: Syntax: Access Level: fwuHMmonRmtID I D ( num erical) of com panion Rem ot e Unit See “ Unit I dent ificat ion” on page 43 NodeAddr1 Read Only Re m ot e I P Addr e ss SNMP MIB: Description: Syntax: Access Level: fwuHMmonRmtIPAddress List of I P addresses of connect ed Rem ot e Unit ( s) I pAddress Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 247 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Host DART Module Parameters Ca r d N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuHstDARTNumber A unique ident ifier for each DART Module Obj ect Range 1 - 8 I nt eger Read Only Ca r d N a m e SNMP MIB: Description: Values: fwuHstDARTName A user defined nam e for each DART Module Alphanum eric Charact ers. Except as first charact er, t he underscore ( _) charact er is allowed. Must be bet ween 5 and 32 charact ers in lengt h, wit h no spaces. Description: Unknown_DART Syntax: Display St ring Access Level: Read- Writ e Ba n d Type SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuHstDARTBandType Band t ype of Host DART Module See “ Band Types” on page 235. -1 BAND- TYPE Read Only Pa ssba n d SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuHstDARTPassBand Passband for t he select ed DART SI ZE ( 0…40) -1 OCTET STRI NG Read- Writ e Ope r a t in g M ode SNMP MIB: Description: Syntax: Access Level: fwuHstDARTOperatingMode Operat ing m ode of t he DART Module ModeType Read- Writ e Page 248 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface D ive r sit y St a t u s SNMP MIB: Description: Values: fwuHstDARTDiversityStatus Diversit y St at us of Host DART Module 0 = Non- diversit y 1 = Diversit y Default: Syntax: I nt eger Access Level: Read Only For w a r d Ga in SNMP MIB: Description: Default: Syntax: Access Level: fwuHstDARTForwardGain Prim ary Gain of Host DART Module GainType Read- Writ e Re ve r se Ga in SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuHstDARTReverseGain Prim ary Gain of Host DART Module 5…36, Unit s = dB, increm ent s 1dB GainType Read- Writ e FPGA St a t u s SNMP MIB: Description: fwuHstDARTFPGAStatus Host DART FPGA St at us; indicat es whet her t he SeRF FPGA can t alk t o t he DART FPGA Values: 0 = SeRF FPGA can t alk t o DART FPGA 1 = SeRF FPGA cannot t alk t o DART FPGA Default: Syntax: I nt eger Access Level: Read Only FPGA Pr ogr a m Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstDARTFPGAProgramVer FPGA version on t he DART Module Display St ring Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 249 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuHstDARTRIADCPartNumber Host DART I nvent ory Dat a - ADC Part Num ber Display St ring Read Only RI Se r ia l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuHstDARTRISerialNumber Host DART I nvent ory Dat a - Serial Num ber Display St ring Read Only RI D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuHstDARTRIDateCode Host DART I nvent ory Dat a Code Display St ring Read Only D ART RI H W Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstDARTRIHWVer Host DART I nvent ory Dat a - HW Version Display St ring Read Only Row St a t us SNMP MIB: Description: Syntax: Access Level: fwuHstDARTRowStatus The st at us of t his concept ual row RowSt at us Read- Creat e Pe a k Ave r a ge I n pu t Pow e r Le ve l 1 SNMP MIB: Description: fwuHstDARTPeakInputPwrLvl1 Peak Average input Power Level1. For Diversit y syst em s, t his will be NA. Default: NA Syntax: DisplaySt ring Access Level: Read Only Page 250 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Pe a k Ave r a ge I n pu t Pow e r Le ve l 2 SNMP MIB: Description: fwuHstDARTPeakInputPwrLvl2 Peak Average input Power level2. For Diversit y syst em s, t his will be NA. Default: NA Syntax: DisplaySt ring Access Level: Read Only M in Ave r a ge I n pu t Pow e r Le ve l 1 SNMP MIB: Description: fwuHstDARTPeakAvgInputPwrLvl1 Minim um Average I nput Power Level1. For Diversit y syst em s, t his will be NA. Default: NA Syntax: DisplaySt ring Access Level: Read Only M in Ave r a ge I n pu t Pow e r Le ve l 2 SNMP MIB: Description: fwuHstDARTPeakAvgInputPwrLvl2 Minim um Average I nput Power Level2. For Diversit y syst em s, t his will be NA. Default: NA Syntax: DisplaySt ring Access Level: Read Only Pe a k I n pu t Pow e r Le ve l 1 SNMP MIB: Description: Default: Syntax: Access Level: fwuHstDARTMinAvgInputPwrLvl1 Peak I nput Power Level2. For Diversit y syst em s, t his will be NA. NA DisplaySt ring Read Only Pe a k I n pu t Pow e r Le ve l 2 SNMP MIB: Description: Default: Syntax: Access Level: fwuHstDARTMinAvgInputPwrLvl2 Peak I nput Power Level2. For Diversit y syst em s, t his will be NA. NA DisplaySt ring Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 251 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Pow e r Le ve l M ode SNMP MIB: Description: Values: fwuHstDARTInputPowerMode DART power level Mode 0 = snapshot 1 = m axHold Default: Syntax: I nt eger Access Level: Read- Writ e Pow e r Le ve l M a x H old Re se t SNMP MIB: Description: Values: fwuHstDARTPwrLevelMaxHoldReset Host DART I nput Power Level Max Hold Reset - 1 = Not Applicable 0 = Norm al 1 = Reset Default: -1 Syntax: I nt eger Access Level: Read- Writ e La st M a x H old Re se t Tim e SNMP MIB: Description: Syntax: Access Level: fwuHstDARTLastMaxHoldResetTime Dat e and Tim e of t he last m axHold reset t im e of t he Host DART Dat eAndTim e Read Only I de n t ify RF Sou r ce SNMP MIB: Description: Values: fwuHstDARTInputSrc I dent ifies whet her t he connect ion is t o BTS/ BDA 1 = BTS 2 = BDA Default: Syntax: I nt eger Access Level: Read- Writ e Host System Card Parameters RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuHstSysCardRIADCPartNumber Rm t I nvent ory Dat a - ADC Part Num ber Display St ring Read Only Page 252 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface RI Se r ia l N um be r SNMP MIB: Description: Syntax: Access Level: fwuHstSysCardRISerialNumber Rm t I nvent ory Dat a - Serial Num ber Display St ring Read Only RI D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuHstSysCardRIDateCode Rm t I nvent ory Dat a - Dat e Code Display St ring Read Only RI H W Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuHstSysCardRIHWVer Rm t I nvent ory Dat a - Hardware Version Display St ring Read Only 1 0 M H z Re fe r e n ce Clock SNMP MIB: Description: Values: fwuHstSysCard10MhzRefClock Syst em Card Reference clock 0- I nt ernal 1- ext ernal ref clock Default: Syntax: I nt eger Access Level: Read- Writ e Clock Pr ior it y Le ve l SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuHstSysCardCPLevel Syst em card m ast er clock priorit y level 1…14 14 I nt eger32 Read- Writ e FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 253 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Ou t pu t Re fe r e n ce Clock SNMP MIB: Description: fwuHstSysCardOutputRefClock Syst em Card Reference clock. Syst em Module support s only 10 MHz and Syst em Board I I support s bot h 10 MHz and 30 MHz Clock out put . Values: 0 = Off 1 = 10 MHz clock 2 = 30 MHz clock Default: 1 for Host 2 for I F Rem ot e Syntax: I nt eger Access Level: Read- Writ e RI H a r dw a r e Ge n e r a t ion SNMP MIB: Description: Values: fwuHstSysCardRIHWGen Host Syst em Card Hardware Generat ion 0 = First Generat ion 1 = Second Generat ion Default: Syntax: I nt eger Access Level: Read Only Remote Unit Parameters Remote Parameters N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtNumber Num ber of t he connect ed Rem ot e Unit . See “ Unit I dent ificat ion” on page 43 Unit I d2 Read Only Nam e SNMP MIB: Description: Values: fwuRmtName User defined nam e of t he Rem ot e Unit . Alphanum eric Charact ers. Except as first charact er, t he underscore ( _) charact er is allowed. Must be bet ween 5 and 40 charact ers in lengt h, wit h no spaces. Syntax: Display St ring Access Level: Read- Writ e Page 254 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Ala r m St a t u s Su m m a r y SNMP MIB: Description: Syntax: Access Level: fwuRmtAlarmStatusSummary Sum m ary of alarm st at us of t he ( connect ed) Rem ot e Unit . Alarm Type Read Only Type SNMP MIB: Description: Syntax: Access Level: fwuRmtType Type of Rem ot e. unit Type Read Only Te m pe r a t u r e M e a su r e m e n t SNMP MIB: Description: Syntax: Access Level: fwuRmtTempMeasurement Tem perat ure of each Rem ot e Unit in celsius. Oct al St ring Read Only Pr ism Un it Re se t SNMP MIB: Description: fwuPrismUnitReset Boolean. Way t o reset t he Rem ot e Unit rem ot ely. Only applicable t o URH Rem ot e Unit s ( URUs) . Values: 0 = Norm al 1 = Reset Default: Default : 0 Syntax: I nt eger Access Level: Read- Writ e Ca t a log St a t e SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtCatalogState Cat alog st at e of Rem ot e Unit . This is used in t he Recovery of t he Rem ot e Unit Cat alogType Read Only Ta ble Row St a t u s SNMP MIB: Description: Syntax: Access Level: fwuRmtGeneralTableRowStatus The st at us of t his concept ual row. RowSt at us Read- Creat e FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 255 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s D ART I d SNMP MIB: Description: Values: Syntax: Access Level: fwuUsrCommLinkTestDartId To ident ify t he DART 1 - 8 Unsigned32 Read- Writ e Prism Remote System Card RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtSysCardRIADCPartNumber Rem ot e Unit I nvent ory Dat a: ADC Part Num ber. Display St ring Read Only RI Se r ia l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtSysCardRISerialNumber Rem ot e Unit I nvent ory Dat a: Serial Num ber Display St ring Read Only RI D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuRmtSysCardRIDateCode Rem ot e Unit I nvent ory Dat a: Dat eCode Num ber Display St ring Read Only RI H a r dw a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSysCardRIHWVersion Rm t I nvent ory Dat a - Hardware Num ber Display St ring Read Only 1 0 M h z Re fe r e n ce Clock SNMP MIB: Description: Values: fwuRmtSysCard10MhzRefClock Rem ot e Syst em Card Reference clock. I t can be int ernal or ext ernal. 0- I nt ernal 1- ext ernal ref clock Description: Syntax: I nt eger Access Level: Read Only Page 256 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Ou t pu t Re fe r e n ce Clock SNMP MIB: Description: fwuRmtSysCardOutputRefClock Rem ot e Syst em Card Reference clock. Syst em Board support s only 10 MHz and Syst em Board I I support s bot h 10 MHz and 30 MHz Clock out put Values: 0 - off 1 - clock10m hz 2 - clock30m hz Default: Syntax: I nt eger Access Level: Read- Writ e RI H a r dw a r e Ge n SNMP MIB: Description: Values: fwuRmtSysCardRIHWGen Rem ot e Syst em Card Hardware Generat ion First Generat ion = 0 Second Generat ion = 1 Syntax: I nt eger Access Level: Read Only Prism Remote SeRF General Lin u x Ke r n e l Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFLinuxKernelVer Linux Kernel Version of t he rem ot e syst em . Display St ring Read Only Linu x Boot Loa de r Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFLinuxBootLoaderVer Linux Boot loader Version of t he rem ot e syst em . Display St ring Read Only Lin u x Fir st St a ge Boot Loa de r Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFLinuxBootLoaderVer Boot Loader1 Version of t he host syst em . Display St ring Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 257 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Com pa ct Fla sh SW Ve r sion SNMP MIB: Description: Values: fwuRmtSERFCompactFlashSWVer Com pact Flash Soft ware Version of t he rem ot e syst em . Form at of: aa.bb.cc.dd where each of aa, bb, cc, dd m ust be bet ween 00 and 99 Syntax: Display St ring Access Level: Read Only PPC H W M on it or SW Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFPPCHWMonSWVer Hardware m onit or process Soft ware Version of t he rem ot e syst em . Display St ring Read Only PPC Applica t ion M on it or SW Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFPPCAPPMonSWVer Applicat ion m onit or process Soft ware Version of t he rem ot e syst em . Display St ring Read Only PPC Age n t SW Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFPPCSNMPAgentSWVer SNMP agent Soft ware Version of t he rem ot e syst em . Display St ring Read Only PPC M a t e M on it or SW Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFPPCMATEMonSWVer Mat e m onit or process Soft ware Version of t he rem ot e syst em . Display St ring Read Only PPC EN ET M on it or SW Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFPPCENETMonSWVer ENET m onit or process Soft ware Version of t he rem ot e syst em . Display St ring Read Only PPC FPGA M on it or SW Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFPPCFPGAMonSWVer FPGA m onit or process Soft ware Version of t he rem ot e syst em . Display St ring Read Only Page 258 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Se RF FPGA Ve r sion SNMP MIB: fwuRmtSERFFPGAVer Syntax: Display St ring Access Level: Read Only RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFRIADCPartNumber Rem ot e SeRF I nvent ory - ADC Part Num ber. Display St ring Read Only pTh r e a d Soft w a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtpThreadSoftwareVer The version num ber of pThread process. DisplaySt ring Read Only W e b Se r ve r Soft w a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtWebServerSwVer The version num ber of web server. DisplaySt ring Read Only RI H a r dw a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFPPCHWMonSWVer Hardware m onit or process Soft ware Version of t he rem ot e syst em . DisplaySt ring Read Only RI H a r dw a r e SNMP MIB: Description: Values: fwuRmtSERFRIHWGen Rem ot e SeRF Hardware Generat ion. First Generat ion = 0 Second Generat ion = 1 Syntax: I nt eger Access Level: Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 259 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Prism Remote SeRF Optics Opt ics N um be r SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtSERFOptSFPNumber A unique ident ifier of each SFP 1 - 8 I nt eger Read Only Opt ics N a m e SNMP MIB: Description: Values: fwuRmtSERFOptSFPName User defined nam e of each Rem ot e SFP. Alphanum eric Charact ers. Except as first charact er, t he underscore ( _) charact er is allowed. Must be bet ween 5 and 32 charact ers wit h no spaces. Syntax: Display St ring Access Level: Read- Writ e Opt ics Type SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFOptSFPType SFP Type - Opt ical Port Type. Opt icsType Read Only Opt ics Color SNMP MIB: Description: Values: Syntax: fwuRmtSERFOptSFPColor SFP wavelengt h in nanom et er. I nt eger32 Read Only REV La u n ch Pow e r SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFOptRevLaunchPowerMeas Value of Rem ot e Receive m easured opt ical power in dbm . Display St ring Read Only For w a r d Re ce ive Pow e r SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFOptFwdLaunchPowerMeas Value of Rem ot e Transm it m easured opt ical power in dbm . Display St ring Read Only Page 260 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Mate Nam e SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtSERFOptMateName Nam e of Rem ot e m at e. I nherit s valid values from Rem ot e nam e DisplaySt ring Read Only M a t e Un it I D SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtSERFOptMateId Num erical I D of com panion Rem ot e Unit . See “ Unit I dent ificat ion” on page 43 NodeAddr1 Read Only M a t e Un it SFP I D SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtSERFOptMateSfpId I dent ifier of SFP t o which t he m at e connect s . 1 - 8 I nt eger32 Read Only M ode SNMP MIB: Description: Values: fwuRmtSERFIPEnable Mode of I P enable RF carrier. 1= I PEnable 2 = I P Disable Default: Syntax: I nt eger Access Level: Read- Writ e SFP D ir e ct ion SNMP MIB: Description: Values: fwuRmtSERFOptMateSfpDir I ndicat es whet her t he fiber is incom ing or out going on t his SFP port . - 1 = Unknown 0 = I n 1 = Out Syntax: I nt eger Access Level: Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 261 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Prism Remote SeRF ENET Switch Et h e r n e t Por t N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtSERFEthPortNumber A unique ident ifier for each Et hernet port . Port num ber, which can be bet ween 1 and 12 Unsigned32 Read Only Et h e r n e t Por t Type SNMP MIB: Description: Values: fwuRmtSERFEthPortType An ident ifier for t he t ype of Et hernet port . Port t ype: Net work port Craft port Managem ent port Swit ch port Syntax: ENET- TYPE Access Level: Read Only Et h e r n e t SFP I d SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthSFPID I dent ifier of SFP t o which t his et hernet port connect s t o. I nt eger32 Read Only Rx - byt e s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortRxBytes Receive byt e count er. Count er64 Read Only Rx - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortRxPkts Receive packet count er. Count er64 Read Only Rx - fsc- e r r or s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortRxFscErrors Receive FCS error count er. Count er64 Read Only Page 262 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Re ce ive - m u lt ica st - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortRxMulticastPkts Receive m ult icast packet count er. Count er64 Read Only Re ce ive - br oa dca st - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortRxBroadcastPkts Receive broadcast packet count er. Count er64 Read Only Rx - fr a gm e n t e d- fr a m e s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortRxFragmtdFrames Receive fragm ent s count er. Count er64 Read Only Rx - j a bbe r - fr a m e s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortRxJabbersFrames Receive j abber count er. Count er64 Read Only Tx - byt e - cou n t e r SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortTxByteCounter Transm it byt e count er Count er64 Read Only Tx - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortTxPkts Transm it packet count er Count er64 Read Only Tx - m u lt ica st - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortTxMulticastPkt Transm it m ult icast packet count er Count er64 Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 263 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Tx - br oa dca st - pa ck e t s SNMP MIB: Description: Syntax: Access Level: fwuRmtSERFEthPortTxBroadcastPkts Transm it broadcast packet count er Count er64 Read Only Prism Remote SeRF FPGA FPGA St a t u s SNMP MIB: Description: Values: fwuRmtSERFFPGAStatus Rem ot e SeRF Card FPGA st at us. 0 = PPC can t alk t o FPGA 1= PPC cannot t alk t o FPGA Default: Syntax: I nt eger Access Level: Read Only Prism Remote DART Ca r d N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtDARTNumber A unique ident ifier for each DART Module Obj ect . 1 - 8 Unsigned32 Read Only Nam e SNMP MIB: Description: Values: fwuRmtDARTName A user defined nam e for each DART Module. Alphanum eric Charact ers. Except as first charact er, t he underscore ( _) charact er is allowed. Must be bet ween 5 and 32 charact ers in lengt h, wit h no spaces. Default: Unknown_DART Syntax: DisplaySt ring Access Level: Read- Writ e Ba n d Type SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuRmtDARTBandType Band t ype of t he Host DART See “ Band Types” on page 235. -1 BandType Read Only Page 264 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Pa ssba n d SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuRmtDARTPassBand Passband for t he select ed DART Size of t he passband, which can be bet ween 0 and 40 -1 Oct et St ring Read- Writ e Ope r a t in g M ode SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTOperatingMode Operat ing m ode of t he DART Module. ModeType Read- Writ e D ive r sit y St a t u s SNMP MIB: Description: Values: fwuRmtDARTDiversityStatus Diversit y St at us of Host DART Module. 1 = Diversit y 0 = Non- diversit y Default: Syntax: I nt eger Access Level: Read- Writ e For w a r d Ga in SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTForwardGain Prim ary Gain in forward pat h of Rem ot e Unit DART Module. GainType Read- Writ e Re ve r se Ga in SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTReverseGain Prim ary Gain in reverse pat h of Rem ot e Unit DART Module. GainType Read Only For w a r d D e la y SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTForwardDelay Rem ot e DART Module forward delay in Micro Seconds. DelayType Read- Writ e FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 265 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Re ve r se D e la y SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTReverseDelay Rem ot e DART Module reverse delay in Micro Seconds DelayType Read- Writ e FPGA Pr ogr a m Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTFPGAProgramVer FPGA Version on t he Rem ot e Unit DART Module. DisplaySt ring Read Only FPGA St a t u s SNMP MIB: Description: fwuRmtDARTFPGAStatus Rem ot e DART FPGA St at us. I t indicat es if t he SeRF FPGA can t alk t o DART FPGA or not . Values: 0 = SeRF FPGA can t alk t o DART FPGA 1 = SeRF FPGA cannot t alk t o DART FPGA Default: Syntax: I nt eger Access Level: Read Only Te m pe r a t u r e M e a su r e m e n t SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTTempMeas Tem perat ure of Rem ot e DART Module. DisplaySt ring Read Only AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTRIADCPartNumber Rem ot e DART I nvent ory Dat a - ADC Part Num ber. Display St ring Read Only Se r ia l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTRISerialNumber Rem ot e DART I nvent ory Dat a - Serial Num ber. Display St ring Read Only Page 266 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTRIDateCode Rem ot e DART I nvent ory Dat a - Dat eCode. Display St ring Read Only RI H a r dw a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTRIHWVer Rem ot e DART I nvent ory Dat a - HW Version. Display St ring Read Only Ta ble Row St a t u s SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTGeneralTableRowStatus The st at us of t his concept ual row. RowSt at us Read- Creat e Act u a l For w a r d D e la y SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTActualForwardDelay Act ual value of Forward delay for Rem ot e DART. I nt eger32 Read Only For w a r d D e la y - Low e r Bou n d SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTForwardLowerboundDelay Lower bound of Forward delay for Rem ot e DART I nt eger32 Read Only For w a r d D e la y - Uppe r Bou n d SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTForwardUpperboundDelay Upper bound of Forward delay for Rem ot e DART. I nt eger32 Read Only Re m ot e D ART Act u a l Re ve r se D e la y SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTActualReverseDelay Reverse delay for Rem ot e DART. I nt eger32 Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 267 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Re ve r se D e la y - Low e r Bou n d SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTReverseLowerboundDelay Lower bound of Reverse delay for Rem ot e DART I nt eger32 Read Only Re ve r se D e la y - Uppe r Bou n d SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTReverseUpperboundDelay Upper bound of Reverse delay for Rem ot e DART I nt eger32 Read Only Pe a k I n pu t Pow e r Le ve l1 SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTPeakInputPwrLvl1 Peak I nput Power Level1 t o a Rem ot e DART. NA DisplaySt ring Read Only Pe a k I n pu t Pow e r Le ve l2 SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTPeakInputPwrLvl2 Peak I nput Power Level2 t o a Rem ot e DART. NA DisplaySt ring Read Only Pe a k Ave r a ge I n pu t Pow e r Le ve l 1 SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTPeakAvgInputPwrLvl1 Peak Average I nput Power Level1 t o a Rem ot e DART. NA DisplaySt ring Read Only Pe a k Ave r a ge I n pu t Pow e r Le ve l 2 SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTPeakAvgInputPwrLvl2 Peak Average I nput Power Level2 t o a Rem ot e DART. NA DisplaySt ring Read Only Page 268 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface M in im u m Ave r a ge I n pu t Pow e r Le ve l 1 SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTMinAvgInputPwrLvl1 Minim um Average I nput Power Level1 t o a Rem ot e DART. NA DisplaySt ring Read Only M in im u m Ave r a ge I n pu t Pow e r Le ve l 2 SNMP MIB: Description: Default: Syntax: Access Level: fwuRmtDARTMinAvgInputPwrLvl2 Minim um Average I nput Power Level2 t o a Rem ot e DART. NA DisplaySt ring Read Only Pow e r Le ve l M ode SNMP MIB: Description: Values: fwuRmtDARTInputPowerMode Rem ot e DART I nput Power Level Mode. 0 = Snap Shot 1 = Max Hold Default: Syntax: I nt eger Access Level: Read- Writ e Pow e r Le ve l M a x H old Re se t SNMP MIB: Description: Values: fwuRmtDARTPwrLevelMaxHoldReset Reset s t he Power Level Max Hold - 1 = Not Applicable 0 = norm al 1 = reset Default: -1 Syntax: I nt eger Access Level: Read- Writ e La st M a x H old Re se t Tim e SNMP MIB: Description: Syntax: Access Level: fwuRmtDARTLastMaxHoldResetTime Dat e and Tim e of t he last m axHold reset t im e of Rem ot e. DisplaySt ring Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 269 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Re ve r se Pa t h Ga in M ode SNMP MIB: Description: fwuRmtDARTReverseGainMode To cont rol gain m ode on t he Reverse Pat h. Applicable t o bot h Classic and Super DARTs. Values: 0 - Norm al 1 - High Default: Syntax: I nt eger Access Level: Read- Writ e Prism Remote LPA LPA N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtLPANumber A unique ident ifier for an LPA. 1 - 4 Unsigned32 Read Only LPA Re se t SNMP MIB: Description: Values: fwuRmtLPAReset Set t his obj ect t o a value of 1 t o cause LPA t o reset it self. 0 = norm al 1 = reset Default: Syntax: I nt eger Access Level: Read- Writ e Ope r a t in g M ode SNMP MIB: Description: Values: fwuRmtLPAOpState The operat ing m odes of Rem ot e Unit LPA 0 = Operat ing 1 = Offline Default: Syntax: I nt eger Access Level: Read Only Page 270 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface LPA Cont r ol SNMP MIB: Description: Values: fwuRmtLPAControl To cont rol t he operat ing m ode of Rem ot e Unit LPA. 0 = Norm al 1 = St andby Default: Syntax: I nt eger Access Level: Read- Writ e M ode l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtLPAPartNum Rem ot e LPA Part Num ber. DisplaySt ring Read Only Se r ia l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtLPASerialNum Rem ot e LPA Serial Num ber. DisplaySt ring Read Only H a r dw a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtLPAHWVer Rem ot e LPA Hardware Version. DisplaySt ring Read Only Soft w a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtLPASWVer Rem ot e LPA Soft ware Version. DisplaySt ring Read Only D e scr ipt ion SNMP MIB: Description: Syntax: Access Level: fwuRmtLPADescr Band t ype of Rem ot e LPA DisplaySt ring Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 271 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Prism Remote Power Detector Pow e r D e t e ct or N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtPowerDetectorNumber I ndex and a unique ident ifier for each power det ect or. 1 - 4 I nt eger32 Read Only RF Pow e r Out put M e a su r e m e nt SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtRFPowerOutputMeas The value of Rem ot e RF Power Out put in dBm Up t o 5 charact ers Oct et St ring Read Only D u ple x e r RI Se r ia l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtPwrDetectorBoardRISerialNum Power Det ect or I nvent ory - Serial Num ber. DisplaySt ring Read Only D u ple x e r RI D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuRmtPwrDetectorBoardRIDateCode Power Det ect or I nvent ory - Dat e Code. DisplaySt ring Read Only D u ple x e r RI H a r dw a r e Ve r sion SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtPwrDetectorBoardRIHWVer Power Det ect or I nvent ory - HW Version. Up t o 8 Charact ers Oct et St ring Read Only D u ple x e r RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtPwrDetectorBoardRIADCPartNum Power Det ect or I nvent ory - ADC Part Num ber. DisplaySt ring Read Only Page 272 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Syst e m VSW R M e a su r e m e n t SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtSystemVswrMeas Measured VSWR value Up t o 8 Charact ers Oct et St ring Read Only Prism Remote LNA/Duplexer LN A N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtLNANumber I ndex and an unique ident ifier for LNA Obj ect s. Num ber t hat ident ifies an LNA and t hat can be from 1 t o 8 I nt eger32 Read Only LN A Type SNMP MIB: Description: Syntax: Access Level: fwuRmtLNAType Rem ot e LNA card t ype. LnaType Read Only RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtLNARIADCPartNumber LNA I nvent ory Dat a - ADC Part Num ber. Display St ring Read Only RI Se r ia l N um be r SNMP MIB: Description: Syntax: Access Level: fwuRmtLNARISerialNumber LNA I nvent ory Dat a - Serial Num ber. Display St ring Read Only RI D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuRmtLNARIDateCode LNA I nvent ory Dat a - Dat e Code. Display St ring Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 273 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s RI H a r dw a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtLNARIHWVer LNA I nvent ory Dat a - HW Version. DisplaySt ring Read Only D uple x e r t ype SNMP MIB: Description: Syntax: Access Level: fwuRmtDuplexerType Duplexer hardware t ype. DuplexerType Read Only Prism Remote RDI Card RD I N u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuRmtRDINumber I ndex and an ident ifier for each RDI . Num ber t hat ident ifies an RDI and t hat can be from 1 t o 4 Unsigned32 Read Only RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtRDIRIADCPartNumber RDI I nvent ory Dat a - ADC Part Num ber. Display St ring Read Only RI Se r ia l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtRDIRISerialNumber RDI I nvent ory Dat a - Serial Num ber. Display St ring Read Only RI D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuRmtRDIRIDateCode RDI I nvent ory Dat a - Dat e Code. DisplaySt ring Read Only Page 274 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface RI H a r dw a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtRDIRIHWVer RDI I nvent ory Dat a - HW Version. Display St ring Read Only Prism Remote RSI Card RI AD C Pa r t N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtRSIRIADCPartNumber Rem ot e I nvent ory Dat a - ADC Part Num ber. Display St ring Read Only Se r ia l N u m be r SNMP MIB: Description: Syntax: Access Level: fwuRmtRSIRISerialNumber Rem ot e I nvent ory Dat a - Serial Num ber. Display St ring Read Only D a t e Code SNMP MIB: Description: Syntax: Access Level: fwuRmtRSIRIDateCode Rem ot e I nvent ory Dat a - Dat e Code. DisplaySt ring Read Only RI H a r dw a r e Ve r sion SNMP MIB: Description: Syntax: Access Level: fwuRmtRSIRIHWVer Rem ot e I nvent ory Dat a - Hardware Version. Display St ring Read Only Re m ot e Ca pa cit y SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuRmtCapacity The num ber of RF m odules t hat m ay be inst alled in t he Rem ot e Unit . Num ber bet ween 1 and 4 Unsigned32 Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 275 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Common Managed Objects Prism DART Mapping I n de x SNMP MIB: Description: Values: Syntax: Access Level: fwuDARTMappingIndex I ndex of DART Mapping Table. Num ber bet ween 0 and 100 Unsigned32 Not Accessible Un it I d SNMP MIB: Description: Syntax: Access Level: fwuUnitID I dent ifier for t he unit HOSTNBR- TYPE Read Only Un it D ART I d SNMP MIB: Description: Values: Syntax: Access Level: fwuUnitDARTID I dent ifier of DART on t he unit Num erical value t hat can be from 1 t o 8 I nt eger32 Read Only Un it SFP I d SNMP MIB: Description: Values: Syntax: Access Level: fwuUnitSFPID I dent ifier of unit SFP connect ed t oward t he m at e DART ( out going) . Num erical value t hat can be from 1 t o 8 I nt eger32 Read Only Un it D ART Pa ssba n d SNMP MIB: Description: Values: Syntax: Access Level: fwuUnitDartPassBand Band- Passband inform at ion of t he linked DART on t he Host side. Num erical value t hat indicat es size, and t hat can be from 0 t o 40 OCTET STRI NG Read Only Page 276 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Mate I d SNMP MIB: Description: Values: Syntax: Access Level: fwuMateID I dent ifier of ( com panion) m at e unit See “ Unit I dent ificat ion” on page 43 REMOTENBR- TYPE Read Only M a t e D ART I d SNMP MIB: Description: Syntax: Access Level: fwuMateDARTId I dent ifier of ( com panion) DART on m at e unit . I nt eger32 Read Only M a t e SFP I d SNMP MIB: Description: fwuMateSFPId I dent ifier of rem ot e side SFP connect ed t oward t he unit DART ( incom ing) Syntax: I nt eger32 Access Level: Read Only M a t e D ART Pa ssba n d SNMP MIB: Description: Syntax: Access Level: fwuMateDartPassbnd Band- Passband inform at ion of t he linked DART on t he Mat e side. OCTET STRI NG Read Only St a r t Tim e Slot on SFP SNMP MIB: Description: fwuSfpStartTimeSlot St art ing t im e slot on t he fiber t hat is carrying t he RF t raffic from unit t o m at e DART Module. Values: 1- 12 Syntax: I nt eger32 Access Level: Read Only En d Tim e Slot on SFP SNMP MIB: Description: fwuSfpEndTimeSlot Ending t im eslot on t he fiber t hat is carrying t he RF t raffic from unit t o m at e DART Module. Values: 1- 12 Syntax: I nt eger32 Access Level: Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 277 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s M a ppin g St a t u s SNMP MIB: Description: Syntax: Access Level: fwuMappingStatus St at us of DART m apping t able RowSt at us Set Schedule System Link Test Syst e m Lin k Te st M ode SNMP MIB: Description: Values: sysLinkTestMode RLM Test for Syst em . 0 = Disable 1 = Enable Syntax: I NTEGER Access Level: Read- Writ e St a r t D a t e a n d Tim e SNMP MIB: Description: Syntax: Access Level: sysLinkStartTime The St art dat e and t im e of linking t est execut ion. Dat eAndTim e Read- Writ e Re cu r r e n ce Tim e SNMP MIB: Description: Values: sysLinkRecurrenceTime Recurrence of syst em link t est , in t erm s of days. 1 - 365 0 = don't recur Syntax: Unsigned32 Access Level: Read- Writ e D ART Ba n d Type SNMP MIB: Description: Values: sysLinkDARTBandType Band t ype ( t he RF DART t ype) of select ed unit s See “ Band Types” on page 235. Ent er 0 t o select all unit s. Syntax: BandType Access Level: Read- Writ e Page 278 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface D ART I d SNMP MIB: Description: Values: Syntax: Access Level: fwuSchLinkTestDartId I n which slot t he DART resides. 1 - 8 I nt eger Read- Writ e SNMP Settings V1 Tr a p Age n t Addr e ss Ove r r ide M ode SNMP MIB: Description: Values: fwuV1TrapAgentAddrOverrideMode V1 t rap agent address override m ode. 0 = Disable 1 = Enable Default: Syntax: I NTEGER Access Level: Read- Writ e V1 Tr a p Age n t Addr e ss Ove r r ide I P Addr e ss SNMP MIB: Description: Syntax: Access Level: fwuV1TrapAgentAddrOverrideIPAddr V1 t rap agent address overriding address DisplaySt ring Read- Writ e SN M P Tr a p Re se n d I n t e r va l SNMP MIB: Description: Values: Syntax: Access Level: fwuSnmpTrapResendInterval I nt erval in m inut es t hat m ust pass before t he t rap is resent 0 t o 1440, where 0 = Disable I nt eger32 Read- Writ e M a x im u m for SN M P Tr a p Re se n d SNMP MIB: Description: Values: Syntax: Access Level: fwuSnmpTrapResendMaximum Maxim um num ber of t im es t rap will be resent wit h 0 t o 360 I nt eger32 Read- Writ e FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Disable = 0 Page 279 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Et h e r n e t M ode m W a k e Up SNMP MIB: Description: Values: fwuEthernetModemWakeUp I f an ext ernal m odem is used, sends a “ wake up” m essage 0 = False 1 = True Syntax: I nt eger32 Access Level: Read- Writ e Register SNMP Trap Manager Row I n de x SNMP MIB: Description: Syntax: Access Level: fwuTrapMgrRowId I ndex for t his t able I nt eger Read- Writ e Tr a p M a n ge r I P Addr e ss SNMP MIB: Description: Values: Syntax: Access Level: fwuTrapMgrIpAddress I P Address of t he regist ered Trap m anager Default = 127.0.0.1 I pAddress Read- Writ e List e n in g Por t SNMP MIB: Description: fwuTrapMgrListeningPort Port at which t he m anager list ens for t he t rap. This value m ust be set by t he user before t he row st at us is m ade act ive. Ot herwise, an error will be indicat ed. Values: 162, or any ot her unreserved port Default: 162 Syntax: I nt eger Access Level: Read- Writ e Com m u n it y SNMP MIB: Description: Values: fwuTrapCommunity Trap Com m unit y for t he m anager Public Privat e Default: Public Syntax: DisplaySt ring Access Level: Read- Writ e Page 280 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Tr a p Ve r sion SNMP MIB: Description: Values: fwuTrapVersion Version of SNMP used for t his t rap dest inat ion. 0 = V1 1 = V2c 2 = I nform Default: Syntax: I nt eger Access Level: Read- Writ e Row St a t us SNMP MIB: Description: Syntax: Access Level: fwuTrapMgrRowStatus The st at us of t his concept ual row. RowSt at us Read- Creat e Geographic Locations GEO Objects Ge o H e a r t be a t Tim e r SNMP MIB: Description: Values: Default: Syntax: Access Level: fwuGeoHeartbeatTimer Heart beat can be sent at t he t im er specified here in m inut es Num ber t hat represent s m inut es, t hat can be from 1 t o 30 20 I nt eger32 Read Only GEO Table Objects I n de x SNMP MIB: Description: Values: Syntax: Access Level: fwuGeoIndex I ndex of Geo t able. Num ber t hat can be from 0 t o 64 Display St ring Read- Writ e Ge o La t it ude SNMP MIB: Description: Syntax: Access Level: fwuGeoLatitude I dent ifies t he Lat it ude of a Rem ot e Unit . Lat AndLong Read- Writ e FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 281 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Ge o Lon git u de SNMP MIB: Description: Syntax: Access Level: fwuGeoLongitude I dent ifies t he Longit ude of a Rem ot e Unit . Lat AndLong Read- Writ e Ge o Re m ot e N a m e SNMP MIB: Description: Syntax: Access Level: fwuGeoRmtName Derived from fwuRmtName. Display St ring Read Only Ge o St a t u s SNMP MIB: Description: Values: fwuGeoStatus St andard SNMP row st at us for t his t able. 0 = not Present 1 = act ive 2 = inact ive Syntax: I nt eger Access Level: Read Only Managed Objects for Traps Prism Input Contact Alarm Management Table Un it I nde x SNMP MIB: Description: Values: Syntax: Access Level: fwuUnitIndex The num ber of unit connect ed. See “ Unit I dent ificat ion” on page 43 NodeAddr1 Read Only Ala r m Code SNMP MIB: Description: Values: fwuSYstemAlarmCode An alphanum eric code t hat uniquely ident ifies an alarm / fault . Each alarm / fault has a unique alphanum eric code. See “ Troubleshoot ing Alarm s” on page 185 or use t he “ I ndex of Alarm s” on page 313 t o find t he page num ber for a specific alarm descript ion, which includes t he alarm code. Syntax: Unsigned32 Access Level: Read Only Page 282 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Con t a ct Ala r m SNMP MIB: Description: Syntax: Access Level: fwuContactAlarm Hardware Assigned Nam e Display St ring Read Only Se ve r it y SNMP MIB: Description: Values: fwuContactAlarmSeverity Severit y of t he alarm 2= Minor 3 = Maj or Default: Minor Syntax: Unsigned I nt eger Access Level: Read- Writ e M ode SNMP MIB: Description: Values: fwuContactAlarmMode Mode of t he Alarm 1= Norm ally Closed 2 = Norm ally Open Default: Syntax: Unsigned I nt eger Access Level: Read- Writ e Ala r m N a m e SNMP MIB: Description: Values: fwuContactAlarmName User Assigned Nam e Alphanum eric Charact ers. Except as first charact er, t he underscore ( _) charact er and spaces are allowed. Must be 5 t o 40 charact ers in lengt h. Default: Blank ( em pt y st ring) Syntax: Display St ring Access Level: Read- Writ e Con t a ct Ala r m En a ble SNMP MIB: Description: Values: fwuContactAlarmEnable Enable/ Disable t he cont act alarm 1 = Enabled 0 = Disabled Default: Enabled Syntax: Unsigned I nt eger Access Level: Unsigned I nt eger FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 283 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s System Active Alarm Table Ala r m Se qu e n ce n u m be r SNMP MIB: Description: Values: Syntax: Access Level: fwuSystemAlarmSequenceNumber I ndex and unique I D for each t rap in Alarm Table. I ndex of t he Alarm Table Unsigned32 Not Accessible Un it N ode Addr e ss SNMP MIB: fwuSystemAlarmTrapNodeAddress Syntax: Unit I d2 Access Level: Read- Writ e Syst e m La be l SNMP MIB: Description: Syntax: Access Level: fwuSystemlabel Syst em Nam e or Host nam e DisplaySt ring Read Only Re m ot e N a m e for Ala r m SNMP MIB: Description: Syntax: Access Level: fwuSystemAlarmRmtName Rem ot e nam e, where t he alarm originat ed. DisplaySt ring Read Only Re m ot e Type for Ala r m SNMP MIB: Description: Syntax: Access Level: fwuSystemAlarmRmtType I dent ifies t he t ype of t he Rem ot e ( PRU or URU) Unit Type Read Only M odu le Type for Ala r m SNMP MIB: Description: fwuSystemAlarmModuleType Hardware m odule t ype, where t he alarm has originat ed like . SeRF, DART, SFP, LPA, LNA. Syntax: ModuleType Access Level: Read Only Page 284 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface M odu le N um be r for Ala r m SNMP MIB: Description: Values: Syntax: Access Level: fwuSystemAlarmModuleNumber Hardware m odule num ber, where t he alarm has originat ed. Bet ween 1 and 8 Unsigned32 Read Only M odu le N a m e for Ala r m SNMP MIB: Description: Syntax: Access Level: fwuSystemAlarmModuleName Nam e of hardware m odule where t rap originat ed. DisplaySt ring Read Only Ala r m Se ve r it y SNMP MIB: Description: Syntax: Access Level: fwuSystemAlarmSeverity Severit y of t he alarm Alarm Type Read Only Ala r m Pa ss Ba n d SNMP MIB: Description: fwuSystemAlarmRFBand Describes t he Band t hat m ay be affect ed due t he raised alarm PCS, GSM, AWS. Syntax: DisplaySt ring Access Level: Read Only Ala r m Tim e SNMP MIB: Description: Syntax: Access Level: fwuSystemAlarmTimeStamp Tim e at t rap in raised. Syst em Dat eand Tim e Read Only Ala r m Code SNMP MIB: Description: Values: fwuSystemAlarmCode An alphanum eric code t hat uniquely ident ifies an alarm / fault . Each alarm / fault has a unique alphanum eric code. See “ Troubleshoot ing Alarm s” on page 185 or use t he “ I ndex of Alarm s” on page 313 t o find t he page num ber for a specific alarm descript ion, which includes t he alarm code. Syntax: Unsigned32 Access Level: Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 285 © 2011 ADC Telecom m unicat ions, I nc. Prism MI B Obj ect s Ala r m H ost N u m be r SNMP MIB: Description: Syntax: Access Level: SystemAlarmHstNbr Num ber ident ifying t he host in t he syst em Unsigned32 Read Only An a log N ode Addr e ss SNMP MIB: Description: Syntax: Access Level: fwuSystemAlarmAnalogAddress Analog Port ion of t he node address Unit I D3 Read Writ e Alarm Management Table Ala r m Code SNMP MIB: Description: Values: fwuSystemAlarmCode An alphanum eric code t hat uniquely ident ifies an alarm / fault . See “ Troubleshoot ing Alarm s” on page 185 or use t he “ I ndex of Alarm s” on page 313 t o find t he page num ber for a specific alarm descript ion, which includes t he alarm code. Syntax: Unsigned32 Access Level: Read Only Ala r m Con t r ol SNMP MIB: Description: Values: fwuSystemAlarmManageable I ndicat es t he abilit y t o Enable or Disable alarm Enable = 1 Disable = 0 Syntax: Updat ed Access Level: Read Only Ala r m Th r e sh old SNMP MIB: Description: Values: fwuSystemAlarmThreshold The t hreshold at which t he alarm is raised ( Whenever applicable) See “ Troubleshoot ing Alarm s” on page 185 or use t he “ I ndex of Alarm s” on page 313 t o find t he page num ber for a specific alarm descript ion, which includes t he alarm t hreshold, if any. Syntax: DisplaySt ring Access Level: Read Only Page 286 © 2011 ADC Telecommunications, Inc FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Using an SNMP I nt erface Ala r m e d M odu le SNMP MIB: Description: Values: fwuSystemAlarmModType I dent ifies t he m odule t ype t hat raised t he alarm . SeRF DART LPA LNA Power Det ect or SFP Syntax: I nt eger32 Access Level: Read Only Alarm Enable Table Ala r m Code SNMP MIB: Description: Values: fwuSystemModuleAlarmcode An alphanum eric code t hat uniquely ident ifies an alarm / fault . See “ Troubleshoot ing Alarm s” on page 185 or use t he “ I ndex of Alarm s” on page 313 t o find t he page num ber for a specific alarm descript ion, which includes t he alarm code. Syntax: Unsigned32 Access Level: Read Only N ode Addr e ss SNMP MIB: fwuSystemTrapNodeAddress Syntax: Unit I d2 Access Level: Read Only Ala r m e d M odu le N um be r SNMP MIB: Description: Values: fwuSystemAlarmModuleNo I dent ifies t he specific m odule t ype t hat raised t he alarm . SeRF DART LPA LNA Power Det ect or SFP Syntax: Unsigned32 Access Level: Read Only FlexWave Prism Elem ent Managem ent Syst em 7.1 User Manual ADCP- 77- 177 • I ssue 1 • July 2011 Page 287 © 2011 ADC Telecom m unicat ions, I nc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : TE106558 Create Date : 2011:12:06 13:34:35-08:00 Modify Date : 2011:12:06 13:37:58-08:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2011:12:06 13:37:58-08:00 Creator Tool : FrameMaker 7.1 Format : application/pdf Title : ADC FlexWave Prism Element Management System 7.1 User Manual Creator : TE106558 Document ID : uuid:318179ef-dc61-48d7-876b-d832bb15e73e Instance ID : uuid:64b0ea74-42f3-4740-816b-05149292ecac Producer : Acrobat Distiller 9.4.5 (Windows) Page Count : 178EXIF Metadata provided by EXIF.tools