ASSALOY SCYICLS2 Microprocessor Controlled Networked Locks User Manual XX XXXX Exhibit Cover

ASSA ABLOY Inc. Microprocessor Controlled Networked Locks XX XXXX Exhibit Cover

Contents

TCP Manual

     5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-SCYICLS2 IC: 6982A-SCYICLS2  FCC Rule Part: 15.225 IC Radio Standards Specification: RSS-210  ACS Report Number:  11-0071.W06.11.A   Manufacturer: Assa Abloy, Inc. Model: TCPIP-M819/M820,TCPWI-M819/M820     Manual
      700™Installation InstructionsML20700 TCPWI1 & TCPIP1SeriesMortise Lockset FM324 04/11Please read these instructions carefully to prevent missing important steps.Please Note: Improper installations may result in damage to the lock and void the factory warranty.Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.                  Misalignment can cause premature wear and a lessening of security.For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Attention Installer       TCPWI1/TCPIP1PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock2Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.1) WarningTable of Contents1) Warning ................................................................................22) General Description .............................................................33) Specifications / Features ....................................................34) Product Illustration .............................................................45) Installation Instructions ......................................................56) TCPIP (PoE) Wiring Instructions........................................197) Operational Check .............................................................22Warning: Changes or modifications to this unit not expressly approved by the party  responsible for compliance could void the user’s authority to operate the equipment.!TCPWI1 FCC NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruc-tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a par-ticular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio/TV technician for help.Statement: The term “IC:” before the radio certification number only signifies that Industry Canada  technical specifications were met.This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne  causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce  dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle  interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.TCPIP1 FCC NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.Industry Canada: The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met.This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Cet appareillage numérique de la classe A répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock3Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Designed specifically for the campus market, the Corbin Russwin Access 700 series mortise Locks are available in WiFi (PWI) and PoE (PIP) configurations. Coupled with third party software the PWI and PIP offers a complete, integrated access control system. The Access 700 may be used for both indoor and outdoor applications (weath-er-protective gasket supplied). HID and iCLASS are registered trademarks of HID Global Corporation.2) General Description3) Specifications / FeaturesHardware Specifications• Latch – Stainless Steel (Easily field reversible without disassembling lockbody)• Deadbolt – Stainless Steel• Door Thickness – 1-3/4” Standard; can be furnished for other door thicknesses upon request. Consult factory.• Case – 12 gauge heavy duty wrought steel• Outside lever controlled by any combination of keypad, magnetic swipe, iCLASS reader, or mechanical key.• Inside lever retracts latch• BHMA Grade 1; UL Fire Listed• Outside lever for iCLASS controlled by HID iCLASS crendtial or other 13.56 MHz credential (such as CSN, Chip Serial Number, read only supported, including MiFare, DesFire, and FeliCa.Electrical Specifications:• 2400 users per lock; 10,000 event audit trail• Multiple time zone and holiday access scheduling• First-In unlock configuration, either by time or by valid time or by user (selectable)• Use existing magstripe ID cards (high or low coercivity)• Card Coercivity: HiCo (400 Oersted) or LoCo (300 Oersted)• Supports 13.56 MHz iCLASS credentials (26-39 bit); supports CSN reads for other common 13.56 MHZ including MiFare, DesFire, and FeliCa.TCPWI - WirelessWiFi 802.11 b/gDC9V, 1.5A (6 AA Alkaline Batteries or Electrical Power)TCPIP - PoEClass 1 Device, as defined by IEEE 802.3af, requires up to 4 watts over structured cabling To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.Observe precautions for handling electrostatic sensitive devices.!PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock4Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.4) Product Illustration-  PoE Lock with Magnetic Card Swipe, 125 kHz Prox and Keypad91112131412467355101158InsideOutsideITEM No. PART No. DESCRIPTION QTY1 795F069 Light Pipe Lens 12 795F145  FIN Escutcheon, O/S, PWI With Keypad 12 795F135  FIN Escutcheon, O/S, PWI Without Keypad 13 795F059 Light Pipe 14 795F039 Keypad Assy 15 795F318 Screw #4-40x1/4 116 795F849 Swipe Reader 17 795F859 Onine Interface PCB 18 795F079 Online Harness 19 795F088 Mounting Plate 110 323F818 Screw, #8-32 x 2 411 743F768 Screw, #8 x 3/8 212 795F839 Electronics, Access 700PWI 1795F829 Electronics, Access 700PIP 113 795F105  FIN Escutcheon, I/S 114 795F197 Screw, #8-32 x 1/2” Torx-Pin 2PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock5Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.4) Product Illustration-  Magnetic Card Swipe With 13.56 MHz iCLASS and Keypad (M820)ITEM No. PART No. DESCRIPTION1 741F579 Outside Mask Assembly 2 741F555 x FIN Outside Escutcheon - iCLASS3 795F039 Slim Style Keypad Assembly4 795F318 #4-40 x 3/16” Machine Screw5 741F599 Swipe Reader Assembly6 741F549 iCLASS Module Assembly 7 795F079 Harness Assembly8 741F589 iCLASS Harness9 741F568 Back Plate10 795F328  #4-32 x 5/16” Plastite Screw123451044498764PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock6Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.1.   Verify Hand and Bevel of door:Illustrations shown are as viewed from the outside or secure side of opening.5) Installation Instructions2.   Prep door according to door template T31167 : visit www.corbinrusswin.com.Left HandHinges Left.Open Inward.“LH”Left HandReverse BevelHinges Left.Open Outward“LHRB”Right HandHinges Right.Open Inward.“RH”Right HandReverse BevelHinges Right.Open Outward“RHRB”Outside of DoorBackplate Mount HolesLock Harness Hole Mortise PocketKeypad Cable Holes     Thumb Turn Hole         Lever Handle HolesInside of DoorLever  Handle HolesThrough Bolt HolesThrough Bolt HolesCylinder HoleRemote Power and POE RacewayPRELIMINARY
ML20700 PWI/PIP Series Mortise Lock7Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.5) Installation Instructions (Continued)3.   Handing of Lock Body:If necessary re-hand latch and move RED locking screw to side of lockbody to side of lock  body to be locked:a. Push in latch while gently pushing on catch plate with screwdriver (Fig. 3a).b. Release latch and remove from lock body.c. Turn over latch and re-install in lock body; Be sure anti-friction latch tail hooks into front (Fig. 3c).d. Hold screwdriver behind tail socket while pushing in latch. Push latch until ‘click’ is heard (Fig. 3b).Note: Pull on latch to make sure it is secure.e. Rotate lock front to match bevel of door by inserting screwdriver into lock mounting holes  and twisting (Fig. 3d).Fig.  3a Fig.  3bMove the RED-HEADED screw tothe Locking Side of the doorFig.  3cAnti-friction Latch 0TailFig.  3dLock FrontPRELIMINARY
ML20700 PWI/PIP Series Mortise Lock8Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Fig.  4a5) Installation Instructions (Continued)4.   Install Lock Body into Door:a. Feed wires through hole on INSIDE of door while installing lock body (Fig. 4a).b. Pull wires through hole while inserting lockbody (Fig. 4b).DO NOT push wires back into cylinder hole. IMPORTANT: Door must remain open during installation. Use door stop. c. Install, but do not tighten two #12 x 1” combination screws through lock body (Fig. 4b). (2) #12 Comination ScrewsInside Face of DoorFig.  4bPRELIMINARY
ML20700 PWI/PIP Series Mortise Lock9Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.5) Installation Instructions (Continued)5.   Install Standard Lever Trim Instructions: Step 2  Step 3 Step 1a  Step 1b Inside Face of Door Outside Face of Door Outsode Face of DoorOutsdide Adapter PlateInside Face of DoorPRELIMINARY
ML20700 PWI/PIP Series Mortise Lock10Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.5) Installation Instructions (Continued)Inside Face of DoorStep 4AStep 5 - Align adjustment bolt with threaded hole in leverAdjustment bolt needs to be threaded in farther.Adjustment bolt needs to be unthreaded.Adjustment bolt fully aligned. Notes:•  Unthread Adjustment Bolt approximately four turns  for a good starting point (After being fully tightened)•  Make sure O/S lever is fully inserted into adapterplate before aligning adjustment bolt.Step 6STANDARD MUSÉOUse Correct Spindle OrientationGood                        Bad                           Lever          5.   Install Standard Lever Trim Instructions (continued):Step 4BInside Face of DoorPRELIMINARY
ML20700 PWI/PIP Series Mortise Lock11Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Step 1Step 2 Inside Face of DoorOutside Face of Door Thread hub intolever using spindleuntil snug Unthread hub 1/2turn then pushspindle into lever6.   Install   Lever Trim: 5) Installation Instructions (Continued)PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock12Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Outside Face of Door14b.   Install  Trim: 5) Installation Instructions (Continued)STANDARD MUSÉOLeverUse the Correct Spindle OrientationBad                         GoodLeverStep 36.   Install   Trim (continued): Inside Face of DoorSet screw in hub faces away from door edgeStep 4PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock13Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Outside Face of Door7/64" Allen WrenchKey and cylinder must be rotated.Incorrect Correct   Step 114b.   Install  Trim: 5) Installation Instructions (Continued)Step 2Step 37.   Install Cylinder and Scalp:PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock14Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Step 18.   Install Turn Piece:5) Installation Instructions (Continued)Step 2Step 3PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock15Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.9.   Install (optional) Weatherseal Gasket: For non-fire rated door applications, an optional gasket may be  used as a weatherseal between the escutcheon and the  outside door surface.  Peel off the adhesive backing on the gasket and  install the gasket along the edge of the outside  escutcheon assembly (Fig. 9a).    10.   Install Inside Mounting Plate:Install face plate using four  #8-32 machine screws.  IMPORTANT: For fire rated doors, also use two #8 surface  mount screws. Correctly position the lock body harness and ground wire.(2) #8 Surface Mount ScrewsRequired for Fire Rated Doors(4) #8-32Machine ScewsOutside Face of DoorFig.  10aSurface Mount ScrewsGround Wire  With Ring TerminalTCPWI OnlyWeatherseal GasketOutside EscutcheonFig. 9aReader Cable M820- iCLASS onlySurface Mount ScrewsLock CablePRELIMINARY
ML20700 PWI/PIP Series Mortise Lock16Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.5) Installation Instructions (Continued)13.  Attach PWI Connectors (For PIP skip to Step 15):  Secure the following connectors to the circuit board as shown (Fig. 13a and 13b Detail).a. Secure the mortise lock body assembly connector (10-pin).b. Secure the mortise keypad/card reader connector (24-pin).Note: Connectors go on only one way. Do not force and do not offset connector.  Be sure they are seated (completely flush). c.  Secure the 9-pin reader cable (M820- iCLASS only). IMPORTANT: Door must remain open duing installation. Use door stop.Fig.  13b DetailFromOutsideTrimFromLockbodyDetail 13bFig. 13aFig. 12a12.  Install Electronics Module:a. Insert the single tab on the electronics module into the single tab at the bottom of the mounting plate.  b. Tilt the module upward and secure the top two tabs into the mounting plate (Fig. 12a). 9-pin  Reader  Cable (iCLASS Only)PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock17Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.5) Installation Instructions (Continued)14.   PWI Battery/ Battery Pack Installation (For PIP skip to Step 15):a.  Place (6) “AA” batteries into the compartment being careful to align polarity (- & +) according to case markings (Fig. 13a).b. Insert battery pack and click into place, making sure polarity terminals on the battery pack are oriented upward (Fig. 13b).Fig.  14a Fig.  14b15.   Attach PIP Connectors:Secure the following connectors onto the circuit board (Fig. 15A and 15B):1. Secure the 10-pin lock body assembly connector (e).2. Secure the 24-pin keypad/card reader connector (d).3. Secure two 4-pin PoE connectors (b and c).  4. Secure 9-pin reader cable (M820- iCLASS only). Route wires from behind backplate through battery compartment. Notes: •  Connectors go on only one way.•  Do not force and do not offset connectors.•  Be sure they are completely seated (flush).Detail 15BFig.  15b DetailFig.  15a(2) 4-Pin PoE connectorsedbc24-pin from reader10-pin from lock bodyedcbf9-pin reader cable (iCLASS only)fPRELIMINARY
ML20700 PWI/PIP Series Mortise Lock18Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Fig.  16a16.   Install Inside Escutcheon:   Install escutcheon using two #8-32 T20 Security Torx Screws.  Be careful not to pinch wires under escutcheon.5) Installation Instructions (Continued)PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock19Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Important Note:  Wiring InstallationIf you are installing PIP (PoE) please go to Page 19 PIP Installation Wiring If you are installing PWI please go to Page 21 Operational CheckContinue With Installation...PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock20Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Cable: CAT 5e or higher24 AWG shielded with drain wireJST4-PinMolex-F Molex-F Molex-MCable: CAT 5e,26 AWG stranded,shielded, 100ohmTIA/EIB-568-B Standard WiringRJ45-M Molex-MRJ45-F Jack Cable: CAT 5e or higher24 AWG shielded, 100ohmApproved Software B-Splice Crimp ConnectorCertified Integrator (CI) supplies and terminates the B-Splice connector and the Male RJ45 connector from harness to  end user provided facility cableSupplied by End UserPoE SwitchPoE LockCeilingSupplied by CICBAPoE Patch PanelDrain Wire Terminated on RackDGroundRing Terminal Secured to Lock  Mounting PlateDrain Wire PoE SwitchRack isTerminated toEarth GroundPatch Cable: PoE Panel toPoE Switch4-Pin MolexA. PoE Frame harness assembly       (From McKinney)B. PoE data hinge (Patent Pending)       (From McKinney)C. PoE Door harness*      (From McKinney)D. Access 700 PIP (PoE Lock)     * Order of installation may vary.          Refer to appropriate sections for instructions.Frame-SideHarnessAssembly(15' length)24AWG Stranded Drain Wire for Earth Ground in 15' Frame HarnessCable drain wire con-cealed in  shrink tubing6) PIP (PoE) Installation Wiring17.   PIP (PoE) Installation Wiring:ABCDPRELIMINARY
ML20700 PWI/PIP Series Mortise Lock21Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.A  Frame Harness InstallationComponents and wire harness supplied by McKinney: Suggested installation. RJ45-M Molex-MCable: CAT 5e or higher24 AWG shielded, 100ohmB-Splice Crimp ConnectorCeilingSupplied by CIEach of the hinge-side harness connectors should end up threaded through a different access hole and matched to the  same size pin con-nector from the door harness:•  4-pin male Molex connector.•  6-pin male Molex connector with ground wire.Notes:•  Connectors only go on one way. They cannot be plugged to incorrect position. •  Do not force and do not offset connectors.•  Be sure they are completely seated (flush).Cut end / ceiling-side PoE harness: TIA/EIB-568-B Standard Wiring1  2  3  4  5  6  7 8Pair Number Wire PIN1 White/Blue White/Blue 5Blue 42 White/Orange White/Orange 1Orange 23 White/Green White/Green 3Green 64 White/Brown White/Brown 7Brown 8Do not confuse pair numbers with pin numbers. A pair number is used for reference only (eg: 10BaseT Ethernet uses pairs 2 & 3). The pin numbers indicate actual physical locations on the plug and jack.1.  Feed cut end of harness into hole on hinge-side through single access hole. 2.  Push one of the connectors back through hole and feed into separate access hole.Hinge side of PoE harness:B6-pin F4-pin M6-pin M4-pin FBDrain WireFrame PoE Hinge (Patent Pending)Frame-SideHarnessAssembly(15' length)24AWG Stranded Drain Wire for Earth Ground in 15' Frame HarnessCable drain wire  concealed in  shrink tubing6) PIP (PoE) Installation Wiring (Continued)Hinge-side harness connectors:•  4-pin male molex connector•  6-pin male molex connector with ground wireLock-side harness connectors:•  Ring terminal•  (2) 4-pin connectors PRELIMINARY
ML20700 PWI/PIP Series Mortise Lock22Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.Hinge InstallationOrder of installation may vary. Refer to appropriate sections for instructions. Hinge-side harness connectors:•  4-pin male Molex connector•  6-pin male Molex connector with ground wireLock-side harness connectors:•  Ring terminal•  (2) 4-pin connectors:•  4-pin Molex connector•  4-pin connectorNotes:•  Connectors go on only one way. They cannot be plugged to incorrect position. •  Do not force and do not offset connectors.•  Be sure they are completely seated (flush).CDoor Harness InstallationOrder of installation may vary. Refer to appropriate sections for in-structions. 1.  Prop door open.2.  Tape the two lock-side 4-pin connectors to the ring terminal.3.  Using the ring terminal, carefully fish the assembly through the door channel to the lock. 4.  Remove tape from ring terminal and door harness connectors. Hinge-side harness connectors:•  4-pin male Molex connector•  6-pin male Molex connector with ground wire        Lock-side harness connectors:•  Ring terminal•  (2) 4-pin connectors:•  4-pin Molex connector•  4-pin connectorNotes:•  Connectors go on only one way. They cannot be plugged to incorrect position. •  Do not force and do not offset connectors.•  Be sure they are completely seated (flush).DJST4-Pin6-pin F 6-pin F 6-pin MCable: CAT 5e,26 AWG stranded,shielded, 100ohm4-pin M 4-pin F4-pin FDrain WirePoE Hinge (Patent Pending)Ring Terminal Secured to Lock Mounting PlateGround4-Pin Molex6) PIP (PoE) Installation Wiring (Continued)PRELIMINARY
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 700™TCPWI1/TPIP7) Operational CheckIMPORTANT: Be sure to test functions prior to closing door.In all cases, perform the following checks:1.  Ensure that inside lever retracts latch (and deadbolt for deadbolt functions).•  For units with cylinders, the following checks apply:Insert key into cylinder and rotatea.  There should be no friction against lock case, wire harness, or any other obstructions. If friction or binding occurs, readjust cylinder and wiring harness to eliminate issues.b.  The key should retract the latch and the key should rotate freely.c.  The key should extend and retract the deadbolt.•  For units without a keypad, add card using LCT  software and test. •  For units with a keypad, add pin and card using LCT software and test. 2.  LED signalling:•  After using a valid credential, a green flash followed by three fast amber flashes indicates a low power condition.  Check the input voltage. If the input voltage is low, disconnect the lock from the power source and check the power source  voltage. If the power source voltage is correct,  inspect the lock wiring for a possible short.•  If the lock loses power, it will flash rapid amber  for approximately one minute. After that, the lock will no longer be functional.3.  When you have completed the tests, close the door to ensure latchbolt and deadbolt fully extend into strike plate without binding.PRELIMINARY

Navigation menu