ASSALOY SCYICLS2 Microprocessor Controlled Networked Locks User Manual XX XXXX Exhibit Cover

ASSA ABLOY Inc. Microprocessor Controlled Networked Locks XX XXXX Exhibit Cover

Contents

TCP Manual

Download: ASSALOY SCYICLS2 Microprocessor Controlled Networked Locks User Manual XX XXXX   Exhibit Cover
Mirror Download [FCC.gov]ASSALOY SCYICLS2 Microprocessor Controlled Networked Locks User Manual XX XXXX   Exhibit Cover
Document ID1450097
Application IDul8b2CIRx1Qo6IELHp2Ecw==
Document DescriptionTCP Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize285.58kB (3569802 bits)
Date Submitted2011-04-18 00:00:00
Date Available2011-04-19 00:00:00
Creation Date2011-04-13 14:36:48
Producing SoftwareAdobe Acrobat 9.0.0
Document Lastmod2011-04-13 14:36:48
Document TitleMicrosoft Word - XX-XXXX - Exhibit Cover.doc
Document CreatorAdobe Acrobat 9.0.0
Document Author: beth.gray

Certification Exhibit
FCC ID: U4A-SCYICLS2
IC: 6982A-SCYICLS2
FCC Rule Part: 15.225
IC Radio Standards Specification: RSS-210
ACS Report Number: 11-0071.W06.11.A
Manufacturer: Assa Abloy, Inc.
Model: TCPIP-M819/M820,TCPWI-M819/M820
Manual
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
700 TCPWI1/TCPIP1
™
Installation Instructions
ML20700 TCPWI1 & TCPIP1Series
Mortise Lockset
FM324 04/11
Attention Installer
Please read these instructions carefully to prevent missing important steps.
Please Note: Improper installations may result in damage to the lock and void the factory warranty.
Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
PR
EL
IM
IN
AR
Misalignment can cause premature wear and a lessening of security.
For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock
Table of Contents
1) Warning
1) Warning.................................................................................2
2) General Description..............................................................3
3) Specifications / Features.....................................................3
4) Product Illustration..............................................................4
5) Installation Instructions.......................................................5
6) TCPIP (PoE) Wiring Instructions........................................19
7) Operational Check..............................................................22
AR
Warning: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
IN
TCPWI1 FCC NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
•
EL
IM
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Statement: The term “IC:” before the radio certification number only signifies that Industry Canada
technical specifications were met.
PR
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject
to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne
causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce
dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle
interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
TCPIP1 FCC NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.
Industry Canada: The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were
met.
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject
to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe A répond à toutes les exigences de l’interférence canadienne causant des règlements
d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce
dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock
2) General Description
Designed specifically for the campus market, the Corbin Russwin Access 700 series mortise Locks are available
in WiFi (PWI) and PoE (PIP) configurations. Coupled with third party software the PWI and PIP offers a complete,
integrated access control system. The Access 700 may be used for both indoor and outdoor applications (weather-protective gasket supplied).
HID and iCLASS are registered trademarks of HID Global Corporation.
3) Specifications / Features
Hardware Specifications
• Latch – Stainless Steel (Easily field reversible without disassembling lockbody)
AR
• Deadbolt – Stainless Steel
• Door Thickness – 1-3/4” Standard; can be furnished for other door thicknesses upon request. Consult factory.
• Case – 12 gauge heavy duty wrought steel
IN
• Outside lever controlled by any combination of keypad, magnetic swipe, iCLASS reader, or mechanical key.
• BHMA Grade 1; UL Fire Listed
IM
• Inside lever retracts latch
Electrical Specifications:
EL
• Outside lever for iCLASS controlled by HID iCLASS crendtial or other 13.56 MHz credential (such as CSN,
Chip Serial Number, read only supported, including MiFare, DesFire, and FeliCa.
• 2400 users per lock; 10,000 event audit trail
PR
• Multiple time zone and holiday access scheduling
• First-In unlock configuration, either by time or by valid time or by user (selectable)
• Use existing magstripe ID cards (high or low coercivity)
• Card Coercivity: HiCo (400 Oersted) or LoCo (300 Oersted)
• Supports 13.56 MHz iCLASS credentials (26-39 bit); supports CSN reads for other common 13.56 MHZ
including MiFare, DesFire, and FeliCa.
TCPWI - Wireless
WiFi 802.11 b/g
DC9V, 1.5A (6 AA Alkaline Batteries or Electrical Power)
TCPIP - PoE
Class 1 Device, as defined by IEEE 802.3af, requires up to 4 watts over structured cabling
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
Observe precautions for handling electrostatic sensitive devices.
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock
4) Product IllustrationPoE Lock with Magnetic Card Swipe, 125 kHz Prox and Keypad
14
13
11
12
11
10
AR
IN
PR
EL
IM
ITEM No.
Inside
Outside
PART No.
DESCRIPTION
QTY
795F069
Light Pipe Lens
795F145 FIN
Escutcheon, O/S, PWI With Keypad
795F135 FIN
Escutcheon, O/S, PWI Without Keypad
795F059
Light Pipe
795F039
Keypad Assy
795F318
Screw #4-40x1/4
11
795F849
Swipe Reader
795F859
Onine Interface PCB
795F079
Online Harness
795F088
Mounting Plate
10
323F818
Screw, #8-32 x 2
11
743F768
Screw, #8 x 3/8
12
795F839
Electronics, Access 700PWI
795F829
Electronics, Access 700PIP
13
795F105 FIN
Escutcheon, I/S
14
795F197
Screw, #8-32 x 1/2” Torx-Pin
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock
4) Product IllustrationMagnetic Card Swipe With 13.56 MHz iCLASS and Keypad (M820)
AR
IN
IM
PR
EL
10
ITEM No.
PART No.
DESCRIPTION
741F579
Outside Mask Assembly
741F555 x FIN
Outside Escutcheon - iCLASS
795F039
Slim Style Keypad Assembly
795F318
#4-40 x 3/16” Machine Screw
741F599
Swipe Reader Assembly
741F549
iCLASS Module Assembly
795F079
Harness Assembly
741F589
iCLASS Harness
741F568
Back Plate
10
795F328
#4-32 x 5/16” Plastite Screw
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions
1.
Verify Hand and Bevel of door:
Right Hand
Hinges Right.
Open Inward.
“RH”
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
“RHRB”
IN
Prep door according to door template T31167 : visit www.corbinrusswin.com.
Through Bolt Holes
Backplate Mount Holes
PR
Remote Power and POE
Raceway
EL
IM
2.
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
“LHRB”
AR
Left Hand
Hinges Left.
Open Inward.
“LH”
Illustrations shown are as viewed from the outside or secure side of opening.
Keypad Cable Holes
Lock Harness Hole
Through Bolt Holes
Cylinder Hole
Thumb Turn Hole
Lever Handle Holes
Lever Handle Holes
Outside of Door
Inside of Door
Mortise
Pocket
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
3.
Handing of Lock Body:
If necessary re-hand latch and move RED locking screw to side of lockbody to side of lock
body to be locked:
a. Push in latch while gently pushing on catch plate with screwdriver (Fig. 3a).
b. Release latch and remove from lock body.
c. Turn over latch and re-install in lock body; Be sure anti-friction latch tail hooks into front (Fig. 3c).
d. Hold screwdriver behind tail socket while pushing in latch. Push latch until ‘click’ is heard (Fig. 3b).
Note: Pull on latch to make sure it is secure.
EL
IM
IN
AR
e. Rotate lock front to match bevel of door by inserting screwdriver into lock mounting holes
and twisting (Fig. 3d).
PR
Fig. 3a
Fig. 3b
Move the RED-HEADED screw to
the Locking Side of the door
Anti-friction Latch 0Tail
Lock Front
Fig. 3d
Fig. 3c
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
4.
Install Lock Body into Door:
a. Feed wires through hole on INSIDE of door while installing lock body (Fig. 4a).
b. Pull wires through hole while inserting lockbody (Fig. 4b).
DO NOT push wires back into cylinder hole.
IMPORTANT: Door must remain open during installation. Use door stop.
Inside Face of Door
EL
IM
IN
AR
c. Install, but do not tighten two #12 x 1” combination screws through lock body (Fig. 4b).
PR
Fig. 4a
(2) #12 Comination Screws
Fig. 4b
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
5.
Install Standard Lever Trim Instructions:
Step 1b
Step 1a
Outsode Face of Door
Inside Face of Door
IM
IN
AR
Outsdide Adapter Plate
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Step 3
Outside Face of Door
PR
Inside Face of Door
EL
Step 2
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
5.
Install Standard Lever Trim Instructions (continued):
Step 4A
Step 4B
Use Correct Spindle Orientation
Inside Face of Door
STANDARD
Good
MUSÉO
Bad
IN
AR
Lever
PR
EL
IM
Step 5 - Align adjustment bolt with threaded hole in lever
Adjustment bolt needs
to be threaded in farther.
Adjustment bolt needs
to be unthreaded.
Adjustment bolt
fully aligned.
Step 6
Notes:
•
Unthread Adjustment Bolt approximately four turns
for a good starting point (After being fully tightened)
•
Make sure O/S lever is fully inserted into adapter
plate before aligning adjustment bolt.
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
10
Inside Face of Door
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
6.
Install
Lever Trim:
Step 1
IN
AR
Unthread hub 1/2
turn then push
spindle into lever
EL
PR
Step 2
IM
Thread hub into
lever using spindle
until snug
Inside Face of Door
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
11
Outside Face of Door
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
6.
Install
Trim (continued):
Step 3
Outside Face of Door
AR
Set screw in hub faces
away from door edge
IM
IN
Inside Face of Door
PR
EL
Step 4
14b. Install Trim:
Use the Correct Spindle Orientation
STANDARD
Bad
MUSÉO
Good
L e v e rLever
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
12
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
7.
Install Cylinder and Scalp:
Step 1
Key and cylinder
must be rotated.
IN
AR
Incorrect
Step 2
PR
EL
IM
7/64" Allen Wrench
Step 3
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
13
Correct
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
8.
Install Turn Piece:
Step 2
EL
PR
Step 3
IM
IN
AR
Step 1
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
14
ML20700 PWI/PIP Series Mortise Lock
9.
Install (optional) Weatherseal Gasket:
For non-fire rated door applications, an optional gasket may be
used as a weatherseal between the escutcheon and the
outside door surface.
Peel off the adhesive backing on the gasket and
install the gasket along the edge of the outside
escutcheon assembly (Fig. 9a).
Weatherseal Gasket
10.
Outside Escutcheon
Install Inside Mounting Plate:
IN
Fig. 9a
IM
IMPORTANT: For fire rated doors,
also use two #8 surface
mount screws. Correctly position
the lock body harness and ground
wire.
AR
Install face plate using four
#8-32 machine screws.
EL
(4) #8-32
Machine Scews
Outside Face of Door
Surface
Mount
Screws
(2) #8 Surface Mount Screws
Required for Fire Rated Doors
PR
TCPWI
Only
Surface
Mount
Screws
Fig. 10a
Reader Cable
M820- iCLASS
only
Lock Cable
Ground Wire
With Ring Terminal
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
15
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
12.
Install Electronics Module:
a. Insert the single tab on the electronics module into the single tab at the bottom of the mounting plate.
AR
b. Tilt the module upward and secure the top two tabs into the mounting plate (Fig. 12a).
13.
IM
IN
Fig. 12a
Attach PWI Connectors (For PIP skip to Step 15):
EL
Secure the following connectors to the circuit board as shown (Fig. 13a and 13b Detail).
a. Secure the mortise lock body assembly connector (10-pin).
b. Secure the mortise keypad/card reader connector (24-pin).
PR
Note: Connectors go on only one way. Do not force and do not offset connector.
Be sure they are seated (completely flush).
c. Secure the 9-pin reader cable (M820- iCLASS only).
IMPORTANT: Door must remain open duing installation. Use door stop.
From
Outside
Trim
9-pin Reader Cable
(iCLASS Only)
Detail 13b
From
Lockbody
Fig. 13a
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Fig. 13b Detail
16
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
14.
PWI Battery/ Battery Pack Installation (For PIP skip to Step 15):
a. Place (6) “AA” batteries into the compartment being careful to align polarity (- & +) according to case
markings (Fig. 13a).
AR
b. Insert battery pack and click into place, making sure polarity terminals on the battery pack are oriented
upward (Fig. 13b).
Fig. 14b
15.
IM
IN
Fig. 14a
Attach PIP Connectors:
EL
Secure the following connectors onto the circuit board
(Fig. 15A and 15B):
1. Secure the 10-pin lock body assembly connector (e).
PR
2. Secure the 24-pin keypad/card reader connector (d).
3. Secure two 4-pin PoE connectors (b and c).
4. Secure 9-pin reader cable (M820- iCLASS only).
•
Connectors go on only one way.
•
Do not force and do not offset connectors.
•
Be sure they are completely seated (flush).
(2) 4-Pin PoE
connectors
24-pin from reader
10-pin from lock body
9-pin reader cable (iCLASS
only)
Route wires from behind backplate through battery
compartment.
Notes:
Fig. 15b Detail
Detail 15B
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Fig. 15a
17
ML20700 PWI/PIP Series Mortise Lock
5) Installation Instructions (Continued)
16.
Install Inside Escutcheon:
Install escutcheon using two #8-32 T20 Security
Torx Screws.
PR
EL
IM
IN
AR
Be careful not to pinch wires under escutcheon.
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
18
Fig. 16a
ML20700 PWI/PIP Series Mortise Lock
Important Note: Wiring Installation
If you are installing PIP (PoE) please go to Page 19 PIP Installation Wiring
PR
EL
IM
IN
AR
If you are installing PWI please go to Page 21 Operational Check
Continue With Installation...
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
19
ML20700 PWI/PIP Series Mortise Lock
6) PIP (PoE) Installation Wiring
17.
PIP (PoE) Installation Wiring:
Frame harness assembly
AA. PoE
(From McKinney)
Door harness*
CC. PoE
(From McKinney)
data hinge (Patent Pending)
BB. PoE
(From McKinney)
700 PIP (PoE Lock)
DD. Access
* Order of installation may vary.
Refer to appropriate sections for instructions.
Certified Integrator (CI) supplies and terminates
the B-Splice connector and the
Male RJ45 connector from harness to
Patch Cable:
end user provided facility cable
Supplied by CI
B-Splice
Crimp Connector
PoE Panel to
PoE Switch
RJ45-M
RJ45-F Jack
IM
Cable drain
wire concealed in
shrink tubing
Molex-M
PoE Switch
Rack is
Terminated to
Earth Ground
PoE Patch Panel
Drain Wire Terminated on Rack
Approved Software
EL
PR
Cable: CAT 5e or higher
24 AWG shielded, 100ohm
Frame-Side
Harness
Assembly
(15' length)
Cable: CAT 5e or higher
24 AWG shielded with drain wire
PoE Switch
IN
Ceiling
AR
Drain Wire
24AWG
Stranded
Drain
Wire for
Earth
Ground in
15' Frame
Harness
Supplied by End User
Molex-F
Cable: CAT 5e,
26 AWG stranded,
shielded, 100ohm
Molex-F Molex-M
JST
4-Pin
4-Pin
Molex
Ground
Ring Terminal
Secured to Lock
Mounting Plate
TIA/EIB-568-B Standard Wiring
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
20
PoE
Lock
ML20700 PWI/PIP Series Mortise Lock
6) PIP (PoE) Installation Wiring (Continued)
Frame Harness Installation
Components and wire harness supplied by McKinney: Suggested installation.
Supplied by CI
Cut end / ceiling-side PoE harness:
B-Splice
Crimp Connector
TIA/EIB-568-B Standard Wiring
3 4 5 6 7
Pair Number
White/Blue
RJ45-M
White/Orange
AR
Ceiling
Cable drain wire
concealed in
shrink tubing
White/Orange
Orange
White/Green
Green
White/Brown
Brown
IM
1. Feed cut end of harness into hole on hinge-side through single access
hole.
2. Push one of the connectors back through hole and feed into separate
access hole.
Each of the hinge-side harness connectors should end up threaded
through a different access hole and matched to the same size pin connector from the door harness:
•
4-pin male molex connector
•
6-pin male molex connector with ground wire
•
4-pin male Molex connector.
•
6-pin male Molex connector with ground wire.
Notes:
•
Connectors only go on one way. They cannot be plugged to
incorrect position.
•
Do not force and do not offset connectors.
•
Be sure they are completely seated (flush).
4-pin M 4-pin F
Lock-side harness connectors:
(2) 4-pin connectors
Blue
Hinge side of PoE harness:
Hinge-side harness connectors:
•
White/Blue
Do not confuse pair numbers with pin numbers. A pair number is
used for reference only (eg: 10BaseT Ethernet uses pairs 2 & 3). The
pin numbers indicate actual physical locations on the plug and jack.
Ring terminal
White/Brown
IN
Molex-M
•
White/Green
PIN
EL
PR
Frame-Side
Harness
Assembly
(15' length)
Cable: CAT 5e or higher
24 AWG shielded, 100ohm
24AWG
Stranded
Drain
Wire for
Earth
Ground in
15' Frame
Harness
Wire
6-pin M
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Frame
21
6-pin F
Drain Wire
PoE Hinge (Patent Pending)
ML20700 PWI/PIP Series Mortise Lock
6) PIP (PoE) Installation Wiring (Continued)
C Hinge Installation
Order of installation may vary. Refer to appropriate sections for instructions.
Hinge-side harness connectors:
•
4-pin male Molex connector
•
6-pin male Molex connector with ground wire
Lock-side harness connectors:
•
Ring terminal
•
(2) 4-pin connectors:
•
4-pin Molex connector
•
4-pin connector
Notes:
Connectors go on only one way. They cannot be plugged to incorrect position.
•
Do not force and do not offset connectors.
•
Be sure they are completely seated (flush).
4-pin M
4-pin F
JST
4-Pin
IN
4-pin F
AR
•
6-pin F
6-pin F
PoE Hinge (Patent Pending)
6-pin M
Cable: CAT 5e,
26 AWG stranded,
shielded, 100ohm
Door Harness Installation
EL
IM
Drain Wire
Order of installation may vary. Refer to appropriate sections for instructions.
PR
1. Prop door open.
2. Tape the two lock-side 4-pin connectors to the ring terminal.
3. Using the ring terminal, carefully fish the assembly through the
door channel to the lock.
4. Remove tape from ring terminal and door harness connectors.
Hinge-side harness connectors:
•
4-pin male Molex connector
•
6-pin male Molex connector with ground wire
Lock-side harness connectors:
•
Ring terminal
•
(2) 4-pin connectors:
•
4-pin Molex connector
•
4-pin connector
Notes:
•
Connectors go on only one way. They cannot be plugged to
incorrect position.
•
Do not force and do not offset connectors.
•
Be sure they are completely seated (flush).
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
22
4-Pin
Molex
Ground
Ring Terminal Secured
to Lock Mounting Plate
700 TCPWI1/TPIP
™
7) Operational Check
IMPORTANT: Be sure to test functions prior to closing door.
In all cases, perform the following checks:
1. Ensure that inside lever retracts latch (and deadbolt for
deadbolt functions).
•
For units with cylinders, the following checks apply:
a. There should be no friction against lock case,
wire harness, or any other obstructions. If friction
or binding occurs, readjust cylinder and wiring
harness to eliminate issues.
AR
b. The key should retract the latch and the key
should rotate freely.
Insert key into cylinder and rotate
c. The key should extend and retract the deadbolt.
For units without a keypad, add card using LCT
software and test.
•
For units with a keypad, add pin and card using LCT
software and test.
2. LED signalling:
•
IM
IN
•
After using a valid credential, a green flash followed
by three fast amber flashes indicates a low power
condition.
EL
Check the input voltage.
•
PR
If the input voltage is low, disconnect the lock from
the power source and check the power source
voltage. If the power source voltage is correct,
inspect the lock wiring for a possible short.
If the lock loses power, it will flash rapid amber
for approximately one minute.
After that, the lock will no longer be functional.
3. When you have completed the tests, close the door to
ensure latchbolt and deadbolt fully extend into strike
plate without binding.
Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : beth.gray
Create Date                     : 2011:04:13 14:36:48-04:00
Modify Date                     : 2011:04:13 14:36:48-04:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2011:04:13 14:36:48-04:00
Creator Tool                    : Adobe Acrobat 9.0.0
Format                          : application/pdf
Title                           : Microsoft Word - XX-XXXX - Exhibit Cover.doc
Creator                         : beth.gray
Document ID                     : uuid:6a4dc7b1-f3f3-4f78-8d40-70eef21b9a0a
Instance ID                     : uuid:8670b771-50e9-4b26-9e10-4c956696a8dd
Producer                        : Adobe Acrobat 9.0.0
Page Count                      : 24
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYICLS2

Navigation menu