ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual A8190B IN100 V3 Bored

ASSA ABLOY Inc. Aperio V3 iN100 RF Module A8190B IN100 V3 Bored

User Manual - A8190B IN100 (V3) Bored

Download: ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual   A8190B IN100  V3  Bored
Mirror Download [FCC.gov]ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual   A8190B IN100  V3  Bored
Document ID3061067
Application ID3kTdzJZP4aOomCvkTocRcw==
Document DescriptionUser Manual - A8190B IN100 (V3) Bored
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize189.79kB (2372344 bits)
Date Submitted2016-07-13 00:00:00
Date Available2016-07-13 00:00:00
Creation Date2016-06-28 15:12:21
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-06-28 15:12:30
Document TitleUser Manual - A8190B IN100 (V3) Bored
Document CreatorAdobe InDesign CC 2015 (Windows)

IN100
with Aperio™
Technology
Cylindrical Lock
Installation Instructions
A8189B
07/16
Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
Table of Contents
Warning ....................................................................................3
General Description..................................................................4
Hardware Specifications..........................................................4
Electronic Specifications..........................................................4
Parts Breakdown......................................................................5
Lock Installation.......................................................................7
Operational Check .................................................................19
Lock LED Indications .............................................................20
Warning
Changes or modifications to this device not expressly approved by ASSA ABLOY
could void the user’s authority to operate the equipment.
FCC:
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada:
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject
to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements
d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce
dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et
d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT
Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting
any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist
or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling
electronic components:
•
Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as
door hinges, latches, and mounting plates especially when mounting electronic components such as readers
and controllers onto the door.
•
Leave components (reader and controller) protected in their respective anti-static bags until ready for installation
•
Do not touch pins, leads or solder connections on the circuit boards
1-800-810-WIRE • www.sargentlock.com • A8189B
IN100 Cylindrical Lock
General Description
The SARGENT® IN100 mortise lock with Aperio™ Technology makes it easy and cost-effective to bring
access control to more doors. It uses local wireless communication between the lock and an Aperio hub to
connect to an access control system, eliminating the greatest cost and inconvenience of traditional access
control – the wiring at the door. The IN100 utilizes HID® multiCLASS SE® technology, it supports heightened
identity security and multiple credentials, including mobile access.
All technology features are supported by the physical security of SARGENT ANSI/BHMA Grade 1 hardware quality components that provide high security, performance and durability.
Hardware Specifications
•
Complete lockset with on-board memory
•
ADA compliant
•
Easily retrofits existing (cylindrical lock)
door preps
•
Latch - 1/2” standard 3/4” throw fire-rated
double doors (optional) (41- prefix)
•
Deadlocking latch - Stainless steel, non handed
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
Lock furnished for 1-3/4” doors.
For other thicknesses, consult factory.
•
ANSI/BHMA A156.25 Listed Grade 1 Compliant
•
Outside lever controlled by contactless reader
or mechanical cylinder
•
May be used for indoor and exterior applications
•
Uses low-rate wireless personal area networks
(IEEE 802.15.4)
•
Multiple time zone and holiday access scheduling
•
First-in unlock or automatic unlock configuration,
based on specified time schedule
•
Uses AES 128-bit wireless encryption*
•
Privacy button
Electronic Specifications
•
Input Power: DC 9V, 1.5A (6 AA alkaline batteries)
•
Optional hard-power 12VDC to 24VDC
•
HID® multiCLASS SE™ technology offers support
for the following credentials:
• High Frequency (13.56 MHz):
• HID iCLASS®
• HID iCLASS SE® (SIO-enabled)
• HID iCLASS® Seos™
• HID MIFARE® SE
• HID DESfire® EV1 SE
• MIFARE Classic
• DESfire EV1
• Low Frequency (125 kHz):
• HID Prox®
• NFC-enabled Mobile Phones
•
*For specific security information, please contact
your local ASSA ABLOY Door Security Solutions
sales consultant or call 800-810-WIRE.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
Warning: SARGENT Mfg. Co. IN100 locksets utilizing a door position switch (DPS) are not rated for,
or intended for use in life safety applications.
1-800-810-WIRE • www.sargentlock.com • A8189B
IN100 Cylindrical Lock
Parts Breakdown
DESCRIPTION
COLOR/TRIM
QTY
IN-100-EM0110G77-IP-B
®
HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
Black
IN-100-EM0110G77-IP-W
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
White
IN-100-EM0110G77-IP-MB-[xxx]*
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
Black with metal trim
IN-100-EM0110G77-IP-MW-[xxx]*
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
White with metal trim
IN-100-EM0110G77-IPS-B
All credentials supported by the IP option plus MIFARE Classic and DESfire EV1
Black
®
®
®
IN-100-EM0110G77-IPS-W
All credentials supported by the IP option plus MIFARE Classic and DESfire EV1
White
IN-100-EM0110G77-IPS-MB-[xxx]*
All credentials supported by the IP option plus MIFARE Classic and DESfire EV1
Black with metal trim
IN-100-EM0110G77-IPS-MW-[xxx]*
All credentials supported by the IP option plus MIFARE Classic and DESfire EV1
White with metal trim
IN-EM04
Mounting plate assembly
N/A
AA battery (alkaline only)
IN-EM02-B
Inside Escutcheon Assembly with Privacy Button - Black Plastic
Black
IN-EM02-W
Inside Escutcheon Assembly with Privacy Button - White Plastic
White
IN-EM02-MB-xxx*
Inside Escutcheon Assembly with Privacy Button - Black Plastic & Metal Trim
Black with metal trim
IN-EM02-MW-xxx*
Inside Escutcheon Assembly with Privacy Button - White Plastic & Metal Trim
White with metal trim
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
PART NUMBER/ORDER STRING
* Specify finish
1-800-810-WIRE • www.sargentlock.com • A8189B
07/31/16
ITEM
IN100 Cylindrical Lock
Parts Breakdown (Continued)
11
12
8*
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
PART NO./ORDER
STRING
ITEM
07/31/16
10
*Adapter Plate/Spacer (10-0847)
is only shipped with orders
that specify 1-3/8” doors.
13
---
10-0043
DESCRIPTION
QTY.
Outside Lever (Reference Catalog for Available Styles)
Lever Retainer Key (In Screw Pack 10-2052)
---
Cylinder Assembly (Reference Catalog for Available Cylinders)
---
Rose (Reference Catalog for Available Styles)
10-0792
Spacer Bushing
10-3049
Outside Rose Spring Assembly
7**
10-3452
Lockbody Assembly 10G77 (Standard Cylinder)
10-3453
Lockbody - LFIC (Removable Core)
10-3454
Lockbody - SFIC
10-3455
Lockbody - Keso
10-3456
Lockbody - Medeco Keymark LFIC & Schlage Full Size
Interchangeable Core
10-0847
Adapter Plate/Spacer (Only Included With 1-3/8” Thick Doors)
10-3192
Latch Assembly
10
10-2052
Screw Pack
11
10-3048
Inside Rose Spring Assembly
12
---
Inside Lever (Reference Catalog for Available Styles)
13
52-5374
Door Position Switch Kit (SPDT)
**The IN100 10G77 cylindrical lock supports Escape Return functionality.
Tools Required:
1-800-810-WIRE • www.sargentlock.com • A8189B
•
#2 Phillips screwdriver
•
Flat head screwdriver
•
Security allen wrench
IN100 Cylindrical Lock
Lock Installation
1 Prepare Door
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
Fig. 1A
LH
LHRB
RH
RHRB
Left Hand
Hinges Left
Open Inward
Left Hand
Reverse Bevel
Hinges Left
Open Outward
Right Hand
Hinges Right
Open Inward
Right Hand
Reverse Bevel
Hinges Right
Open Outward
B. Prepare Door
Prior to installation, all holes must be free of burrs, debris and sharp edges.
Raceway for Power
(Optional)
Cable Hole
Inside of Door
Through-bolt
Holes
External
DPS
holes
Raceway for Power
(Optional)
Cable Hole
Raceway for
Lockbody
Harness
Raceway for
Lockbody
Harness
Through-bolt Holes
Lever Handle
Hole
Through-bolt Holes
Cylindrical
Pocket
and
Latch
Holes
Pre-drilled
Tap Holes
Fig. 1B Wood Door Preparation
1-800-810-WIRE • www.sargentlock.com • A8189B
07/31/16
Outside of Door
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Prepare door according to appropriate template (see website www.intelligentopenings.com).
• Field Template: A8149 (ships with product)
• Door Manufacturer’s Template: 4712
IN100 Cylindrical Lock
Centerline of
Latch Front and
Strike
2 Install Strike
Install strike in the door frame (Fig. 2).
(2) #8-32 x 3/4"
Latch Screws
Fig. 2
3 Install Latchbolt
1. Install latch with beveled bolt facing the strike.
2. Attach with two screws but DO NOT tighten completely at this time.
See section 8 - Secure Lock to the Door.
Inside of Door
IMPORTANT: Latch bevel must match door bevel and
deadlocking latch must stop on strike when door is closed.
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Strike
Deadlocking Latch
Fig. 3B
Fig. 3A
4 Install Door Position Switch (DPS)
1. Push wires through raceway toward lock prep.
2. Push DPS firmly into place by hand.
Inside of Door
Note: DO NOT TAP SWITCH WITH ANY TOOL.
3. Install magnet into door frame. Push firmly into place by hand.
See A7983.
4. To connect DPS to lock controller per diagram, refer to the wiring in
Step #10 (Page 15).
DPS
(Door Position Switch)
CAUTION: if DPS is not installed or is installed
improperly, door status monitoring features will
not function.
Fig. 4
1-800-810-WIRE • www.sargentlock.com • A8189B
IN100 Cylindrical Lock
5 Lock Adjustments
A. Lock Preset:
• Lockbody holes: 12 and 6 o’clock (Fig. 5).
The lock is shipped “preset” and does not require adjustment for 1-3/4” thick doors.
Outside of Door
Fig. 5
NOTE: Adjusting for a thicker door requires removal of the outside lever, scalp and spacer bushing;
see the following sections.
If preset lock does not require adjustment, proceed to Section 7 - Install Lock.
1-800-810-WIRE • www.sargentlock.com • A8189B
07/31/16
Preset Lock
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Door thickness:
1-3/4” thick
IN100 Cylindrical Lock
6 Through-Bolt and Door Thickness Adjustment (If Required)
A. Remove Outside Lever
1. Insert key, rotate 45° clockwise and hold.
2. Depress lever retainer with push pin tool (provided).
3. Pull lever outward.
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Outside of Door
B. How To Change Cylinder (If Necessary)
Fig. 6A
1. With outside lever in hand, use standard pliers
to pull out cylinder retainer.
2. Remove key and cylinder from lever.
3. Insert new cylinder.
4. Secure by pressing cylinder retainer flush with the lever.
Cylinder
Retainer
Cylinder
Spacer
Key
Outside
Lever
Cylinder
Fig. 6B
Washers required for
30- prefix
(10 Line Lever)
to accept
Schlage cylinder
(no cylinder provided)
10
1-800-810-WIRE • www.sargentlock.com • A8189B
Push Pin Tool
IN100 Cylindrical Lock
C. Through-Bolt and Door Thickness Adjustment
1. (If necessary) remove outside lever, scalp
and spacer bushing (Fig. 6C).
Spacer Bushing
Scalp
Outside Lever
Fig. 6C
Refer to markings on through-bolt post (Fig. 6C Detail).
1-3/4” Thick Doors
2” Thick Doors
Fig. 6C Detail
3. Re-install spacer bushing to align with back
of lever, scalp, and lever (Fig. 6D).
Fig. 6D
1-800-810-WIRE • www.sargentlock.com • A8189B
11
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
2. Rotate mounting plate to either align with through-bolt holes in
door, or adjust for proper door thickness (Fig. 6D).
IN100 Cylindrical Lock
7 Install Lock
1. From outside of door feed lockbody harness into the lockbody hole (Fig. 7A).
For metal door: Feed harness through inside of door (not shown).
2. Continue to feed harness into raceway (towards top of door), exiting raceway
hole on inside of door (Fig. 7B).
3. Slide lockbody into cross-bore hole from outside of door.
4. Lockbody must engage both the latch unit prongs and tail piece (Fig. 7C).
IMPORTANT:
• Door must remain open during installation (use door stop)
• Lockbody must be centered in the door
• Tuck excess wires into raceway to avoid pinching or damaging wires
NOTE: Cable lengths exaggerated for illustrative purposes.
Outside of Door
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Inside of Door
Ground Ring
Terminals
Fig. 7B Detail
Fig. 7A
Fig. 7C Detail
12
1-800-810-WIRE • www.sargentlock.com • A8189B
IN100 Cylindrical Lock
8 Secure Lock to the Door
1. Slide inside rose assembly and spacer bushing over lockbody.
2. Position ground lug between (top) #10-32x1-1/4” through-bolt
and rose assembly (Fig. 8A).
NOTE: Proper placement of ground wire (Fig. 8B) will prevent
pinching/damage to the ground wire.
Inside of Door
3. Secure rose assembly with (2) #10-32x1-1/4” through-bolts.
4. Secure latch by fully tightening (2) #6 x 3/4” self-tapping screws
(refer to previous section 3 - Install Latchbolt).
NOTE: Cable lengths exaggerated for illustrative purposes.
Ground Wire
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 8A
9 Assemble Inside Trim
1. Verify spacer bushing is inserted horizontally and
aligned with lever (Fig. 9).
2. Place rose over shaft of lockbody against the
surface of the door; hand-tighten, turning clockwise.
Inside of
Door
3. Attach lever. Push until engaged.
Rose
Fig. 9
Inside lever
1-800-810-WIRE • www.sargentlock.com • A8189B
13
07/31/16
Fig. 8B Detail
IN100 Cylindrical Lock
10 Outside Reader Installation
1. Orient the reader so the LED lens is at the top (Fig. 10A).
2. Feed the cable/connector through the door (from outside to inside).
3. Install the reader to the outside of door by aligning the mounting posts with the door
preparation holes. Hold the reader flush against door while ensuring proper alignment.
NOTE: Cable lengths exaggerated for illustrative purposes.
Outside of Door
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
LED
Reader Assembly
with Harness
Fig. 10A
14
1-800-810-WIRE • www.sargentlock.com • A8189B
IN100 Cylindrical Lock
10 Outside Reader Installation (Continued)
4. Feed the reader harness and DPS connectors through the inside mounting assembly
(and gasket if required*). See Figure 11B.
IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 11B, C) - it will damage wires and
the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 11C).
5. Tuck excess cable into wire hole on inside of door.
6. Begin to secure the mounting assembly by partially tightening the (2) through-bolts on the
inside of the door while ensuring proper alignment as you secure the reader (Fig. 11B).
NOTE: Cable lengths exaggerated for illustrative purposes
Gasket*
Mounting
Plate
Through-bolt
Door Position
Switch
Through-bolt
Lockbody
Harness
Ground Ring
Terminal
Fig. 10C
Fig. 10B
6. Secure ground lug with #6-32 machine screw (Fig. 10C).
*Gasket is required for outdoor installations. Do not use gasket for fire-rated openings.
If installing with gasket; separate gasket from mounting plate to feed cables/connectors
through holes as indicated (Fig. 10B).
Once cables/connectors are fed through, reattach gasket to mounting plate.
1-800-810-WIRE • www.sargentlock.com • A8189B
15
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Reader Harness
IN100 Cylindrical Lock
10 Outside Reader Installation (Continued)
Installation of Connectors
CAUTION - Do not touch or allow debris to enter connector contacts.
DPS (4-pin)
9-24VDC
Power*
Secure the following connectors to their respective terminals (Fig. 11D):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
Ground
Lug
*NOTE: Optional 2-pin external 9-24VDC power connector.
IMPORTANT: Do not run wires through bottom hole in plate - it will
damage wires and the controller connector.
Route wires around flange, do not route wires through
the flange hole (Fig. 11B, D).
Fig. 11D
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
C. When all connections have been made, tuck excess cable
into wire hole on inside of door.
Fully
tighten
Secure Mounting Plate
D. Secure the mounting assembly while ensuring proper
alignment of outside reader and tighten the (2) through-bolts
on the inside of the door to secure the reader (Fig. 11E).
E. Secure the 24-pin card reader connector (Fig. 11F).
Fig. 11E
Reader
(24-pin)
Board-to-Board
Connector
Fig. 11F
16
1-800-810-WIRE • www.sargentlock.com • A8189B
Lock
Body
(10-pin)
IN100 Cylindrical Lock
11 Installation of Inside Component Assembly (Controller)
1. Insert top tabs of controller into slots on mounting plate (Fig. 12).
2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller
toward door until tab on bottom snaps securely into place on mounting plate.
CAUTION: To avoid possible damage to board-to-board connectors,
care should be taken when securing controller to mounting
plate. If there is resistance when securing, detach controller
to determine cause before re-attaching controller.
Fig. 12
1-800-810-WIRE • www.sargentlock.com • A8189B
17
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Controller
IN100 Cylindrical Lock
13 Battery Installation
1. Place (6) “AA” alkaline batteries in the compartment, being
careful to align polarity properly (Fig. 12).
2. After batteries are installed, there is a slight delay; then red and
green flash*, audible “beep” and lock motor will cycle.
AA Batteries (6)
*See Section 8 - LED Indications for more information
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 12
14 Inside Cover Installation
1. Assemble cover by hooking top edge on inside
mounting plate.
2. Carefully press bottom of cover toward door without
pinching or damaging wires.
3. Secure cover utilizing security allen wrench (provided).
Inside
Cover
Security Allen
Screw
Fig. 13
18
1-800-810-WIRE • www.sargentlock.com • A8189B
IN100 Cylindrical Lock
Operational Check
1. Insert key into cylinder and rotate (Fig. 14A).
There should be no friction against lock case, wire
harness or any other obstructions.
2. Check that the key retracts the latch.
Fig. 14A
Note: The credential should approach the inscription
on the reader as indicated (Fig. 14B) to ensure
the credential is read properly.
Do not wave credential.
Fig. 14B
1-800-810-WIRE • www.sargentlock.com • A8189B
19
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
The key should rotate freely.
3. Try the inside lever; ensure it retracts latch.
4. Present a valid credential* (Fig. 14B) to unlock
outside lever; turn lever handle to ensure latch retracts.
07/31/16
IN100 Cylindrical Lock
LED Indications
The communication hub has a single LED. It supports an optical scheme of red,
green and yellow.
The indication scheme is described by the figures below:
Communication Hub LED indications
Figure 1.
Communication hub normal
operation LED indication
2 sec.
Online
Green
Aperio® lock
offline
EAC offline
Green + one
red flash
Green + two red flashes
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Aperio® lock and
EAC offline
Green + three
red flashes
UHF
communication
Yellow + off,
fast flash
Some special LED indication schemes are
used during lock maintenance actions:
2 sec.
Figure 2.
Communication hub
maintenance LED indication
Pairing active
Yellow + green
Ethernet LED indication
The LED on the AH40 communication hub indicates both the
status of the Ethernet link level and ethernet communication:
2 sec.
Figure 3.
AH40 Communication hub
Ethernet LED indication
Ethernet link
connected
Ethernet
communication
Green
Green +
off fast flash
*For more information, refer to Aperio Online Quick Installation Guide
Document No: ST-001322-PF Date: 2015-12-23
20
1-800-810-WIRE • www.sargentlock.com • A8189B
IN100 Cylindrical Lock
Lock LED indications
The lock has three LEDs. They support an optical scheme with red, yellow and green.
The indication scheme is described by the figures below:
EAC response
time
Access granted,
EAC offline or online
Access denied,
EAC online
Force closed in remote
open/office mode
Busy blink, com hub
busy with other locks
Access denied,
EAC offline
Lock mechanism is
blocked when closing 1)
Error in lock,
maintenance required
Tamper
One yellow flash after card, two
flashes before PIN (.125 second)
One yellow flash (.25 second)
One green flash
(1 sec.)
One red flash
(1 sec.)
Five yellow flashes and
one red flash (.25 second)
Continuous yellow flashes
(.25 seconds every second)
Three red flashes
(.5 second each)
Continuous red flashes
(.125 seconds every 1 sec.)
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can’t close)
Ten red flashes (.125 sec. each)
repeated every 10 sec.
Time to replace
the battery
Continuous yellow flashes
(.25 seconds every 5 sec.)
Battery reached end
of life, lock disabled
Continuous red flashes
(.25 seconds every 5 sec.)
V3 USB cable detection
action occurred
Five yellow flashes
(.25 second each)
1) When the lock mechanism is blocked (lock jammed) the lever must be turned to
release the lock mechanism.
Some special LED indication schemes are used during lock maintenance actions:
Figure 5. Lock hub normal
operation LED indication
Enter configuration
mode
Five yellow flashes
(.125 second each)
1-800-810-WIRE • www.sargentlock.com • A8189B
21
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Card access
(configurable)
Enter PIN
07/31/16
Figure 4. Lock normal operation LED
indication
Card + PIN access
(configurable)
IN100 Cylindrical Lock
Lock Self-Test LED indication
After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using
a series of red and green LED flashes as described by the figures below.
LED indication after power up/replacement of the battery
8.3.1
Battery not fully charged
Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at the
right voltage or a backward battery has been installed; battery not fully charged; energy counter
not reset or no Power on self-test done.
Error in lock,
maintenance required
8.3.2
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can’t close)
Test pass
1 red (1s) + 1 green (1s), Power on self-test passed, see table below.
8.3.3
One red, one green flash
(1 second)
POST Successful
Figure 6. Lock POST LED
indication
Test fail
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
1 red (1s) + 3 blinks (500ms, green or red), at least one test failed (red), see table below.
If a fatal error is detected the lock will enter an Error state and continuously indicating fatal error
and will not read cards nor unlock.
1 sec
0.5 sec
0.5 sec
0.5 sec
FATAL ERROR
CABLE ERROR
MECHANICAL ERROR
22
FATAL ERROR
Tests core functionality. MCUs, memory and
internal communication, etc.
CABLE ERROR
Tests communication between the different
parts in the system, i.e. different boards
connected with a wire.
MECHANICAL ERROR
Test related to moving parts of the lock.
1-800-810-WIRE • www.sargentlock.com • A8189B
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-810-WIRE (9473) • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A8189B - 07/16

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00
Create Date                     : 2016:06:28 15:12:21-04:00
Metadata Date                   : 2016:06:28 15:12:30-04:00
Modify Date                     : 2016:06:28 15:12:30-04:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Instance ID                     : uuid:a3200c06-1142-402d-bf8e-79a0ebbdf5b4
Original Document ID            : xmp.did:70C65E3111BAE111B42DD5693CF104AB
Document ID                     : xmp.id:d61162e3-c4d5-0247-a42f-0d8f3b257e20
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:4a989c0b-c95a-164c-ac9f-de5f6fd975f6
Derived From Document ID        : xmp.did:4a989c0b-c95a-164c-ac9f-de5f6fd975f6
Derived From Original Document ID: xmp.did:70C65E3111BAE111B42DD5693CF104AB
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2016:06:28 15:12:21-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 24
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYMCA1

Navigation menu