ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual A8190B IN100 V3 Mortise

ASSA ABLOY Inc. Aperio V3 iN100 RF Module A8190B IN100 V3 Mortise

User Manual - A8190B IN100 (V3) Mortise

A8190B
07/16
Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
with Aperio
Technology
Mortise Lock
Installation Instructions
IN100
1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
1
2
3
4
5
6
7
Table of Contents
Warning ...................................................................................3
General Description .................................................................4
Specifications ..........................................................................4
System Overview .....................................................................4
Parts Breakdown .....................................................................5
Lock Installation ......................................................................7
Operational Check ................................................................19
Lock LED Indications .............................................................20
Changes or modifications to this device not expressly approved by ASSA ABLOY could void the
user’s authority to operate the equipment.
Warning
1
FCC:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada:
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is
subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements
d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2)
ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located
or operating in conjunction with any other antenna or transmitter.”
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
8
!
To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic
components:
Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges,
latches, and mounting plates especially when mounting electronic components such as readers and controllers onto the door.
Leave components (reader and controller) protected in their respective anti-static bags until ready for installation
Do not touch pins, leads or solder connections on the circuit boards
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un
type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques
de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte
que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une
communication satisfaisante.
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT
Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When
retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult
with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes
and ratings.
4 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
!To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
General Description
2
The SARGENT® IN100 mortise lock with Aperio™ Technology makes it easy and cost-effective to bring
access control to more doors. It uses local wireless communication between the lock and an Aperio hub to
connect to an access control system, eliminating the greatest cost and inconvenience of traditional access
control – the wiring at the door. The IN100 utilizes HID® multiCLASS SE® technology, it supports heightened
identity security and multiple credentials, including mobile access.
All technology features are supported by the physical security of SARGENT ANSI/BHMA Grade 1 hardware -
quality components that provide high security, performance and durability.
Hardware Specifications
3
Complete lockset with on-board memory
ADA compliant
Easily retrofits existing door preps (mortise)
Latch - Stainless steel
Optional deadbolt - Hardened steel
Guardbolt - Stainless steel, non handed
Handing (RH/RHR/LH/LHR) must be specified,
but is easily field-reversible without opening
the lock case
Case - 12 gauge heavy duty wrought steel
Cylinder retracts latchbolt (and deadbolt)
Inside lever retracts latch and deadbolt
simultaneously
Lock furnished for 1-3/4” doors.
For other thicknesses, consult factory.
UL Listed (3 hr.)
Outside lever controlled by any combination of
contactless reader or mechanical cylinder
Electronic Specifications
4
*For specific security information, please contact
your local ASSA ABLOY Door Security Solutions
sales consultant or call 800-810-WIRE.
Input Power: DC 9V, 1.5A (6 AA alkaline batteries)
Optional hard-power 12VDC to 24VDC
HID® multiCLASS SE® technology offers support
for the following credentials:
High Frequency (13.56 MHz):
HID iCLASS®
HID iCLASS SE® (SIO-enabled)
HID iCLASS® Seos
HID MIFARE® SE
HID DESfire® EV1 SE
MIFARE Classic
DESfire EV1
Low Frequency (125 kHz):
HID Prox®
NFC-enabled Mobile Phones
Note: A weather-protective gasket is required for exterior applications.
Uses low-rate wireless personal area networks
(IEEE 802.14.4)
Multiple time zone and holiday access scheduling
First-in unlock or automatic unlock configuration,
based on specified time schedule
Uses AES 128-bit wireless encryption*
Privacy button
Warning: SARGENT Mfg. Co. IN100 locksets utilizing a door position switch (DPS) are not rated for,
or intended for use in life safety applications.
ITEM PART NUMBER/ORDER STRING DESCRIPTION COLOR/TRIM QTY
1 IN-100-EM01[locktype]*-IP-B HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
Black 1
IN-100-EM01[locktype]*-IP-W HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
White 1
IN-100-EM01[locktype]*-IP-MB-[xxx]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
Black with metal trim 1
IN-100-EM01[locktype]*-IP-MW-[xxx]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
White with metal trim 1
IN-100-EM01[locktype]*-IPS-B All credentials supported by IP option plus MIFARE Classic and DESfire EV1 Black 1
IN-100-EM01[locktype]*-IPS-W All credentials supported by IP option plus MIFARE Classic and DESfire EV1 White 1
IN-100-EM01[locktype]*-IPS-MB-[xxx]* All credentials supported by IP option plus MIFARE Classic and DESfire EV1 Black with metal trim 1
IN-100-EM01[locktype]*-IPS-MW-[xxx]* All credentials supported by IP option plus MIFARE Classic and DESfire EV1 White with metal trim 1
2 IN-EM04 Mounting plate assembly 1
3 N/A AA battery 6
4 IN-100-EM02-B Inside Escutcheon Assembly with Privacy Button - Black Plastic Black 1
IN-100-EM02-W Inside Escutcheon Assembly with Privacy Button - White Plastic White
IN-100-EM02-MB-xxx** Inside Escutcheon Assembly with Privacy Button - Black Plastic & Metal Trim Black with metal trim
IN-100-EM02-MW-xxx** Inside Escutcheon Assembly with Privacy Button - White Plastic & Metal Trim White with metal trim
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 5
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
Warning: SARGENT Mfg. Co. IN100 locksets utilizing a door position switch (DPS) are not rated for,
or intended for use in life safety applications.
5
1*
4
3
1
2
** Specify finish
Parts Breakdown
ITEM PART NUMBER/ORDER STRING DESCRIPTION COLOR/TRIM QTY
1 IN-100-EM01[locktype]*-IP-B HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
Black 1
IN-100-EM01[locktype]*-IP-W HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
White 1
IN-100-EM01[locktype]*-IP-MB-[xxx]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
Black with metal trim 1
IN-100-EM01[locktype]*-IP-MW-[xxx]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
White with metal trim 1
IN-100-EM01[locktype]*-IPS-B All credentials supported by IP option plus MIFARE Classic and DESfire EV1 Black 1
IN-100-EM01[locktype]*-IPS-W All credentials supported by IP option plus MIFARE Classic and DESfire EV1 White 1
IN-100-EM01[locktype]*-IPS-MB-[xxx]* All credentials supported by IP option plus MIFARE Classic and DESfire EV1 Black with metal trim 1
IN-100-EM01[locktype]*-IPS-MW-[xxx]* All credentials supported by IP option plus MIFARE Classic and DESfire EV1 White with metal trim 1
2 IN-EM04 Mounting plate assembly 1
3 N/A AA battery 6
4 IN-100-EM02-B Inside Escutcheon Assembly with Privacy Button - Black Plastic Black 1
IN-100-EM02-W Inside Escutcheon Assembly with Privacy Button - White Plastic White
IN-100-EM02-MB-xxx** Inside Escutcheon Assembly with Privacy Button - Black Plastic & Metal Trim Black with metal trim
IN-100-EM02-MW-xxx** Inside Escutcheon Assembly with Privacy Button - White Plastic & Metal Trim White with metal trim
*7976 / 7977 / 7978 / 7979 (example: IN-100-EM017976-IP-B)
6 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
Parts Breakdown (Continued)
5
9
10
5 6
5
Tools Required:
#2 Phillips screwdriver
Flat head
T20 Torx® driver
Security allen wrench
11
3
1 2
10
5
5
5
4
7
8
ITEM PART NO/ORDER
STRING DESCRIPTION QTY
1 Consult Factory #41 Mortise cylinder 1
2 13-2131 97 Ring 1
3*IN-100-7976-hand-finish Lock body with deadbolt with cylinder 1
IN-100-7977-hand-finish Lock body with deadbolt without cylinder
IN-100-7978-hand-finish Lock body without deadbolt with cylinder
IN-100-7979-hand-finish Lock body without deadbolt without cylinder
4 77-4081 130W Turn lever 1
5 79-2162 Trim pack 1
6 Consult Factory Rose
7 Consult Factory Inside lever 1
8 79-0035 Without deadbolt 1
79-0036 With deadbolt (shown)
9 52-5374 Door Position Switch (DPS) kit 1
10 77-4236 Mortise screw pack: wood and metal lock body screws, faceplate
screws, and strike screws - specify finish
1
11 Consult Factory Outside trim 1
12 A8150 Field prep template (not shown) 1
13 4713 Door manufacturers template (not shown) 1
14 A8190 Instructions (this manual) 1
*Escape return functionality is not available with the IN100 7900 mortise lock
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 7
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
Lock Installation
LH
Left Hand
Hinges Left
Open Inward
LHRB
Left Hand
Reverse Bevel
Hinges Left
Open Outward
RH
Right Hand
Hinges Right
Open Inward
RHRB
Right Hand
Reverse Bevel
Hinges Right
Open Outward
Fig. 1A
1 Prepare Door
6
B. Door Preparation
Prior to installation, all holes must be free of burrs, debris and sharp edges.
Prepare door according to appropriate template (see website www.intelligentopenings.com).
Field Template: A8150 (ships with product)
Door Manufacturer’s Template: 4713
Outside Cylinder Hole
(only with cylinder
installation)
Outside of Door
Cable Hole
Lever Handle
Hole
Through-bolt
Hole
Mortised
Pocket
Fig. 1B
External DPS
Hole
Lever Post
Holes
Wood Door
shown
Raceway for Power
(Optional) Raceway for Power
(Optional)
Inside of Door
8 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
2 How to Change Hand of Lock body
1. Position lock body so the red surface of the locking piece is visible.
2. Insert blade type screwdriver into locking piece slot to rotate
locking piece.
3. Push locking piece toward the back of the lock
body and rotate the locking piece 180°.
Note: Red indicates locked (outside) side.
Fig. 2B
A. Reverse Lock Hand
1. Rotate the latchbolt 180°.
2. Flip deadlatch by hand to match bevel of latchbolt.
B. Reverse Latch Hand
Locking piece
Locking
piece
Fig. 2A
180°
3 Configure the DIP Switch Settings
IMPORTANT: The DIP-switch settings located at the bottom of the mortise lock body*
must be set prior to lock installation.
Handing
RH & RHR
LH & LHR
*Patent Pending
Deadlatch
Up
Down
Fig. 3
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 9
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
5 Install Lock body
1. Feed the wire harness through the mortise pocket
and inside preparation hole as shown in Fig. 5.
2. Carefully push the lock body into the pocket while lightly
applying tension to the wire harness.
Note: Do not pull the lock into the pocket with the
harness alone. Ensure that the wire harness is not
pinched between the lock and the mortise pocket.
3. Insert (2) #12-24 screws into the lock body
and partially tighten with a screw driver.
Mortise
Connectors
Fig. 5
Outside of Door
(2) #12-24 screws
Wire Hole
Ground Wire
4 Install Door Position Switch (DPS)
1. Insert DPS into the raceway on the latch edge of the door.
2. Push wires through raceway toward lock prep.
3. Push DPS firmly into place by hand.
Note: DO NOT TAP SWITCH WITH ANY TOOL.
4. Install magnet into door frame. Push firmly into place by hand.
See A7983.
5. To connect DPS to lock controller per diagram, refer to the wiring
in Step #10.
Fig. 4
Door Position
Switch (DPS)
10 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
Fig. 6B Fig. 6C
Outside of Door
6 Outside Cylinder Installation
Rosette
Spring
Cylinder
IMPORTANT: Position cylinder so that the
SARGENT logo is positioned correctly.
Correct Incorrect
Fig. 6A
1. Slide the spring and the rosette onto the cylinder.
2. Rotate the cylinder into cylinder hole with fingers.
3. Insert key 75% of the way and utilize the key to rotate the cylinder
into the rest of the cylinder hole.
Note: Do not attempt to tighten all the way.
4. Verify that orientation of cylinder has the SARGENT logo as shown
in Fig. 6A.
5. Hand tighten the cylinder clamp screw with Phillips screwdriver to
prevent unscrewing of the cylinder (Fig 6C).
6. Test cylinder function:
Key retracts latchbolt and deadbolt (7976 function).
Key retracts latchbolt (7978 function).
Cylinder not present for 7977 and 7979 functions.
Cylinder
Clamp Screw
Phillips
Screwdriver
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 11
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
Inside of DoorOutside of Door
DPS
Fig. 7B
Fig. 7A
7 Assemble Outside Trim
1. With outside lever horizontal (and handle pointing toward door hinge), insert the mounting posts through
outside of door and lock body.
Make certain the lever spindle is properly engaged inside the lock body (Fig 7A).
2. On the inside of the door, insert spindle into square hole of mortise lock, with spindle slot directed away
from the mortise lock body, and aligned with the set screw hole in the Inside adapter (Fig 7B).
3. Slide inside adapter and plate assembly over spindle and secure with (2) 8-32 X 5/8” Phillips
oval head and lock washer machine screws.
Note: Ensure that position of set screw hole on inside adapter is oriented to match location of hole in
inside lever handle.
Wire Harness
(From Lock Body)
Spindle
Outside Trim
Spindle
Fig. 7A Detail
Outside Trim Set Screw Hole
Ground Wire
12 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
Fig. 8
Set Screw
Inside Lever
Spindle
Rose
1. Place inside rose flush against door surface and rotate first counter-clockwise to seat the threads,
then clockwise to securely tighten.
2. Slide lever onto spindle until fully seated. Be sure handle is horizontal and facing the hinge side of
the door. Push lever onto spindle so minimum gap is visible.
3. Tighten the set screw securely with a T20 Torx® driver.
4. Finish securely tightening (2) #12-24 lock body screws.
5. Before closing the door, test that the lever is functional and ensure
smooth operation of the latchbolt.
8
Install Inside Rose and Inside Lever Assembly
Inside of Door
#12-24 screws
1. Insert thumb turn into preparation hole and engage slot in lock body.
2. Orient mounting plate so screw hole is vertical (aligned with preparation holes).
3. Secure plate with Phillips screw provided.
4. Test thumb turn for function by retracting and projecting the deadbolt
(7976 and 7977 functions only).
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 13
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
9 Install Thumb Turn
1. Insert thumb turn into preparation hole and engage slot in lock body.
2. Orient mounting plate so screw hole is vertical (aligned with preparation holes).
3. Secure plate with Phillips screw provided.
4. Test thumb turn for function by retracting and projecting the deadbolt
(7976 and 7977 functions only).
10
Attach Front Plate
Attach front plate with (2) Phillips head screws.
Outside of Door
(2) Phillips
head screws
Fig. 9
Thumb Turn
Inside of Door
Phillips
screw
Fig. 10
14 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
11
Outside Reader Installation
1. Orient the reader so the LED lens is at the top.
2. Feed the cable/connector through the door (from outside to inside).
3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes.
Hold the reader flush against door while ensuring proper alignment.
LED
Reader Assembly
with Harness
Fig. 11A
Outside of Door
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 15
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
11
Outside Reader Installation (Continued)
NOTE: Cable lengths exaggerated
for illustrative purposes
*Gasket is required for outdoor installations. Do not use gasket for fire-rated openings.
If installing with gasket; separate gasket from mounting plate to feed cables/connectors
through holes as indicated (Fig. 11B).
Once cables/connectors are fed through, reattach gasket to mounting plate.
Gasket* Inside
Mounting Plate
Fig. 11B
Inside of Door
Door Position
Switch (DPS)
Lock Body
Harness
Reader
Harness
Ground Ring
Terminal
Through-bolt
Through-bolt
Fig. 11C
7. Secure ground lug with #6-32 machine screw (Fig.11C).
4. Feed the reader harness and DPS connectors through the inside mounting assembly
(and gasket if required*). See Figure 11B.
IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 11B, C) - it will damage wires and
the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 11C).
5. Tuck excess cable into wire hole on inside of door.
6. Begin to secure the mounting assembly by partially tightening the (2) through-bolts on the
inside of the door while ensuring proper alignment as you secure the reader (Fig. 11B).
16 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
11
Outside Reader Installation (Continued)
Secure the following connectors to their respective terminals (Fig. 11D):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
CAUTION - Do not touch or allow debris to enter connector contacts.
IMPORTANT: Do not run wires through bottom hole in plate - it will
damage wires and the controller connector.
Route wires around flange, do not route wires through
the flange hole (Fig. 11D, F).
E. Secure the 24-pin card reader connector (Fig. 11F).
Ground
Lug
DPS (4-pin)
A
Lock
Body
(10-pin)
Fig. 11D
B
Reader
(24-pin)
Board-to-Board
Connector
Fig. 11F
D
D. Secure the mounting assembly while ensuring proper
alignment of outside reader and tighten the (2) through-bolts
on the inside of the door to secure the reader (Fig. 11E).
Secure Mounting Plate
Installation of Connectors
*NOTE: Optional 2-pin external 9-24VDC power connector.
9-24VDC
Power*
C. When all connections have been made, tuck excess cable
into wire hole on inside of door.
Fig. 11E
Fully
tighten
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 17
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
12
Installation of Inside Component Assembly
1. Insert top tabs of controller into slots on mounting plate (Fig. 12).
2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward
door until tab on bottom snaps securely into place on mounting plate.
CAUTION: To avoid possible damage to board-to-board connectors,
care should be taken when securing controller to mounting
plate. If there is resistance when securing, detach controller
to determine cause before re-attaching controller.
Inside of Door
Fig. 12
18 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
Fig. 13
AA Batteries (6)
13
Battery Installation
1. Place (6) “AA” alkaline batteries in the compartment, being
careful to align polarity properly (Fig. 13).
2. After batteries are installed, there is a slight delay; then red
and green flash, audible “beep” and lock motor will cycle.
*See Section 8 - LED Indications for more information
14
Inside Cover Installation
1. Assemble cover by hooking top edge on inside
mounting plate.
2. Carefully press bottom of cover toward door
without pinching or damaging wires.
3. Secure cover utilizing security allen wrench.
Fig. 14
Inside
Cover
Security
Allen Screw
Inside of Door
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 19
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
For 7976- and 7978-function mortise locks with cylinders:
1. Insert key into cylinder and rotate.
There should be no friction against lock case, wire harness or
any other obstructions.
2. Check that the key retracts the latch:
the key should rotate freely.
3. Throw the deadbolt (if present): Check that the
key retracts both the deadbolt and the latch.
4. Try the inside lever:
Ensure it retracts latch and deadbolt (if provided).
5. Present a valid credential* to unlock outside lever; turn lever to
ensure latch retracts.
Operational Check
7
Fig. 15B
Fig. 15A
Note: The credential should approach the inscription
on the reader as indicated (Fig. 14B) to ensure
that the credential is read properly.
Do not wave credential.
*Depending upon availability of access control system,
either a (denied) red flash or a green and lock motor
cycle (access granted).
20 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
8LED Indications
Communication Hub LED indications
The communication hub has a single LED. It supports an optical scheme with red, green and yellow.
The indication scheme is described by the figures below:
Figure 1.
Communication hub normal
operation LED indication
2 sec.
Online Green
Aperio® lock Green + one
red flash
offline
EAC offline
Aperio® lock and Green + three
red flashes
EAC offline
UHF Yellow + off,
fast flash
communication
Some special LED indication schemes* are
used during lock maintenance actions:
2 sec.
Figure 2.
Communication hub maintenance
LED indication Pairing active Yellow + green
Ethernet LED indication
The LED on the AH40 communication hub* indicates both the status of
the Ethernet link level and ethernet communication:
2 sec.
Figure 3.
AH40 Communication hub
Ethernet LED indication Ethernet link
connected Green
Ethernet Green +
communication off fast flash
Green + two red flashes
*For more information, refer to Aperio Online Quick Installation Guide
(Document No: ST-001322-PF Date: 2015-12-23)
07/31/16
1-800-810-WIRE • www.sargentlock.com • A8190B 21
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
1)
Lock LED indications
The lock has three LEDs. They support an optical scheme of red, yellow and green.
The indication scheme is described by the figures below:
Figure 4. Lock normal operation LED
indication
One yellow flash after card, two
flashes before PIN (.125 second)
Card + PIN access
(configurable)
Access granted, One green flash
(1 sec.)
EAC offline or online
Access denied, One red flash
(1 sec.)
EAC online
Force closed in remote Five yellow flashes and
open/office mode one red flash (.25 second)
Busy blink, com hub
busy with other locks
Continuous yellow flashes
(.25 seconds every second)
Access denied, Three red flashes
(.5 second each)
EAC offline
Lock mechanism is Continuous red flashes
blocked when closing (.125 seconds every 1 sec.)
Error in lock, Ten red flashes (.125 sec. each)
maintenance required (Repeated every 10 sec. if lock can’t close)
Ten red flashes (.125 sec. each)
repeated every 10 sec.
Tamper
Time to replace Continuous yellow flashes
(.25 seconds every 5 sec.)
the battery
Battery reached end
of life, lock disabled
Continuous red flashes (.25
seconds every 5 sec.)
1) When the lock mechanism is blocked (lock jammed) the lever must be turned to
release the lock mechanism.
Some special LED indication schemes are used during lock maintenance actions:
Figure 5. Lock hub normal
operation LED indication Enter configuration Five yellow flashes
(.125 second each)
mode
One yellow flash (.25 second)
Card access
(configurable)
Enter PIN
EAC response
time
V3 USB cable detection
action occurred
Five yellow flashes
(.25 second each)
22 1-800-810-WIRE • www.sargentlock.com • A8190B
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
IN100 Mortise Lock
Lock Self-Test LED indication
After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated
using a series of red and green LED flashes as described by the figures below.
8.3.1 Battery not fully charged
8.3.2 Test pass
1 red (1s) + 1 green (1s), Power on self-test passed, see table below.
Error in lock, Ten red flashes (.125 sec. each)
maintenance required (Repeated every 10 sec. if lock can’t close)
LED indication after power up/replacement of the battery
Figure 6. Lock POST LED
indication
8.3.3 Test fail
1 red (1s) + 3 blinks (500ms, green or red), at least one test failed (red), see table below.
FATAL ERROR
CABLE ERROR
MECHANICAL ERROR
FATAL ERROR Tests core functionality - MCUs, memory and
internal communication, etc.
CABLE ERROR Tests communication between the different
parts in the system, i.e. different boards
connected with a wire.
MECHANICAL ERROR Test related to moving parts of the lock.
1 sec 0.5 sec 0.5 sec 0.5 sec
One red, one green flash
POST Successful (1 second)
If a fatal error is detected the lock will enter an Error state and continuously indicating
fatal error and will not read cards nor unlock.
Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at the
right voltage or a backward battery has been installed; battery not fully charged; energy counter
not reset or no Power on self-test done.
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-810-WIRE (9473) • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience. A8190B - 07/16

Navigation menu