ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual A8190B IN100 V3 Mortise

ASSA ABLOY Inc. Aperio V3 iN100 RF Module A8190B IN100 V3 Mortise

User Manual - A8190B IN100 (V3) Mortise

Download: ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual   A8190B IN100  V3  Mortise
Mirror Download [FCC.gov]ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual   A8190B IN100  V3  Mortise
Document ID3061068
Application ID3kTdzJZP4aOomCvkTocRcw==
Document DescriptionUser Manual - A8190B IN100 (V3) Mortise
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize194.86kB (2435767 bits)
Date Submitted2016-07-13 00:00:00
Date Available2016-07-13 00:00:00
Creation Date2016-06-28 15:14:36
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-06-28 15:14:48
Document TitleUser Manual - A8190B IN100 (V3) Mortise
Document CreatorAdobe InDesign CC 2015 (Windows)

IN100
with Aperio™
Technology
Mortise Lock
Installation Instructions
A8190B
07/16
Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
Table of Contents
Warning ....................................................................................3
General Description..................................................................4
Specifications...........................................................................4
System Overview......................................................................4
Parts Breakdown......................................................................5
Lock Installation.......................................................................7
Operational Check .................................................................19
Lock LED Indications..............................................................20
Warning
Changes or modifications to this device not expressly approved by ASSA ABLOY could void the
user’s authority to operate the equipment.
FCC:
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada:
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is
subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements
d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2)
ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located
or operating in conjunction with any other antenna or transmitter.”
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un
type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques
de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte
que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une
communication satisfaisante.
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT
Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When
retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult
with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes
and ratings.
To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic
components:
•
Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges,
latches, and mounting plates especially when mounting electronic components such as readers and controllers onto the door.
•
Leave components (reader and controller) protected in their respective anti-static bags until ready for installation
•
Do not touch pins, leads or solder connections on the circuit boards
1-800-810-WIRE • www.sargentlock.com • A8190B
IN100 Mortise Lock
General Description
®
The SARGENT IN100 mortise lock with Aperio™ Technology makes it easy and cost-effective to bring
access control to more doors. It uses local wireless communication between the lock and an Aperio hub to
connect to an access control system, eliminating the greatest cost and inconvenience of traditional access
control – the wiring at the door. The IN100 utilizes HID® multiCLASS SE® technology, it supports heightened
identity security and multiple credentials, including mobile access.
All technology features are supported by the physical security of SARGENT ANSI/BHMA Grade 1 hardware quality components that provide high security, performance and durability.
Hardware Specifications
•
Complete lockset with on-board memory
•
Case - 12 gauge heavy duty wrought steel
•
ADA compliant
•
Cylinder retracts latchbolt (and deadbolt)
•
Easily retrofits existing door preps (mortise)
•
•
Latch - Stainless steel
Inside lever retracts latch and deadbolt
simultaneously
•
Optional deadbolt - Hardened steel
•
•
Guardbolt - Stainless steel, non handed
Lock furnished for 1-3/4” doors.
For other thicknesses, consult factory.
•
Handing (RH/RHR/LH/LHR) must be specified,
but is easily field-reversible without opening
the lock case
•
UL Listed (3 hr.)
•
Outside lever controlled by any combination of
contactless reader or mechanical cylinder
Note: A weather-protective gasket is required for exterior applications.
• Input Power: DC 9V, 1.5A (6 AA alkaline batteries)
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
07/31/16
Electronic Specifications
• Optional hard-power 12VDC to 24VDC
• HID® multiCLASS SE® technology offers support
for the following credentials:
• High Frequency (13.56 MHz):
• HID iCLASS®
• HID iCLASS SE® (SIO-enabled)
• HID iCLASS® Seos™
• HID MIFARE® SE
• HID DESfire® EV1 SE
• MIFARE Classic
• DESfire EV1
• Low Frequency (125 kHz):
• HID Prox®
• NFC-enabled Mobile Phones
•
Uses low-rate wireless personal area networks
(IEEE 802.14.4)
•
Multiple time zone and holiday access scheduling
•
First-in unlock or automatic unlock configuration,
based on specified time schedule
•
Uses AES 128-bit wireless encryption*
•
Privacy button
*For specific security information, please contact
your local ASSA ABLOY Door Security Solutions
sales consultant or call 800-810-WIRE.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
Warning: SARGENT Mfg. Co. IN100 locksets utilizing a door position switch (DPS) are not rated for,
or intended for use in life safety applications.
1-800-810-WIRE • www.sargentlock.com • A8190B
IN100 Mortise Lock
Parts Breakdown
1*
DESCRIPTION
COLOR/TRIM
QTY
IN-100-EM01[locktype]*-IP-B
®
HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE
SE, HID DESfire® EV1 SE, HID Prox®
Black
IN-100-EM01[locktype]*-IP-W
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
White
IN-100-EM01[locktype]*-IP-MB-[xxx]*
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
Black with metal trim
IN-100-EM01[locktype]*-IP-MW-[xxx]*
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®
White with metal trim
IN-100-EM01[locktype]*-IPS-B
All credentials supported by IP option plus MIFARE Classic and DESfire EV1
Black
®
®
®
IN-100-EM01[locktype]*-IPS-W
All credentials supported by IP option plus MIFARE Classic and DESfire EV1
White
IN-100-EM01[locktype]*-IPS-MB-[xxx]*
All credentials supported by IP option plus MIFARE Classic and DESfire EV1
Black with metal trim
IN-100-EM01[locktype]*-IPS-MW-[xxx]*
All credentials supported by IP option plus MIFARE Classic and DESfire EV1
White with metal trim
IN-EM04
Mounting plate assembly
N/A
AA battery
IN-100-EM02-B
Inside Escutcheon Assembly with Privacy Button - Black Plastic
Black
IN-100-EM02-W
Inside Escutcheon Assembly with Privacy Button - White Plastic
White
IN-100-EM02-MB-xxx**
Inside Escutcheon Assembly with Privacy Button - Black Plastic & Metal Trim
Black with metal trim
IN-100-EM02-MW-xxx**
Inside Escutcheon Assembly with Privacy Button - White Plastic & Metal Trim
White with metal trim
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
PART NUMBER/ORDER STRING
*7976 / 7977 / 7978 / 7979 (example: IN-100-EM017976-IP-B)
** Specify finish
1-800-810-WIRE • www.sargentlock.com • A8190B
07/31/16
ITEM
IN100 Mortise Lock
Parts Breakdown (Continued)
10
10
11
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
ITEM
PART NO/ORDER
STRING
Consult Factory
DESCRIPTION
#41 Mortise cylinder
13-2131
97 Ring
3*
IN-100-7976-hand-finish
Lock body with deadbolt with cylinder
IN-100-7977-hand-finish
Lock body with deadbolt without cylinder
IN-100-7978-hand-finish
Lock body without deadbolt with cylinder
IN-100-7979-hand-finish
Lock body without deadbolt without cylinder
77-4081
130W Turn lever
79-2162
Trim pack
Consult Factory
Rose
Consult Factory
Inside lever
79-0035
Without deadbolt
79-0036
With deadbolt (shown)
52-5374
Door Position Switch (DPS) kit
10
77-4236
Mortise screw pack: wood and metal lock body screws, faceplate
screws, and strike screws - specify finish
11
Consult Factory
Outside trim
12
A8150
Field prep template (not shown)
13
4713
Door manufacturers template (not shown)
14
A8190
Instructions (this manual)
*Escape return functionality is not available with the IN100 7900 mortise lock
QTY
1-800-810-WIRE • www.sargentlock.com • A8190B
Tools Required:
•
#2 Phillips screwdriver
•
Flat head
•
T20 Torx® driver
•
Security allen wrench
IN100 Mortise Lock
Lock Installation
1 Prepare Door
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
Fig. 1A
LH
LHRB
RH
RHRB
Left Hand
Hinges Left
Open Inward
Left Hand
Reverse Bevel
Hinges Left
Open Outward
Right Hand
Hinges Right
Open Inward
Right Hand
Reverse Bevel
Hinges Right
Open Outward
B. Door Preparation
Prior to installation, all holes must be free of burrs, debris and sharp edges.
Wood Door
shown
Raceway for Power
(Optional)
Through-bolt
Hole
External DPS
Hole
Outside Cylinder Hole
(only with cylinder
installation)
Cable Hole
Mortised
Pocket
Lever Handle
Hole
Lever Post
Holes
Fig. 1B
1-800-810-WIRE • www.sargentlock.com • A8190B
07/31/16
Inside of Door
Outside of Door
Raceway for Power
(Optional)
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Prepare door according to appropriate template (see website www.intelligentopenings.com).
• Field Template: A8150 (ships with product)
• Door Manufacturer’s Template: 4713
IN100 Mortise Lock
2 How to Change Hand of Lock body
A. Reverse Lock Hand
1. Position lock body so the red surface of the locking piece is visible.
2. Insert blade type screwdriver into locking piece slot to rotate
locking piece.
3. Push locking piece toward the back of the lock
body and rotate the locking piece 180°.
Note: Red indicates locked (outside) side.
Deadlatch
B. Reverse Latch Hand
1. Rotate the latchbolt 180°.
2. Flip deadlatch by hand to match bevel of latchbolt.
Locking piece
Fig. 2B
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
180°
Locking
piece
Fig. 2A
3 Configure the DIP Switch Settings
IMPORTANT: The DIP-switch settings located at the bottom of the mortise lock body*
must be set prior to lock installation.
Handing
Up
RH & RHR
*Patent Pending
Down
LH & LHR
Fig. 3
1-800-810-WIRE • www.sargentlock.com • A8190B
IN100 Mortise Lock
4 Install Door Position Switch (DPS)
1. Insert DPS into the raceway on the latch edge of the door.
2. Push wires through raceway toward lock prep.
3. Push DPS firmly into place by hand.
Note: DO NOT TAP SWITCH WITH ANY TOOL.
Door Position
Switch (DPS)
4. Install magnet into door frame. Push firmly into place by hand.
See A7983.
5. To connect DPS to lock controller per diagram, refer to the wiring
in Step #10.
5 Install Lock body
1. Feed the wire harness through the mortise pocket
and inside preparation hole as shown in Fig. 5.
Fig. 4
2. Carefully push the lock body into the pocket while lightly
applying tension to the wire harness.
Note: Do not pull the lock into the pocket with the
harness alone. Ensure that the wire harness is not
pinched between the lock and the mortise pocket.
3. Insert (2) #12-24 screws into the lock body
and partially tighten with a screw driver.
Wire Hole
(2) #12-24 screws
Fig. 5
Ground Wire
1-800-810-WIRE • www.sargentlock.com • A8190B
07/31/16
Mortise
Connectors
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Outside of Door
IN100 Mortise Lock
6 Outside Cylinder Installation
1. Slide the spring and the rosette onto the cylinder.
2. Rotate the cylinder into cylinder hole with fingers.
3. Insert key 75% of the way and utilize the key to rotate the cylinder
into the rest of the cylinder hole.
Note: Do not attempt to tighten all the way.
4. Verify that orientation of cylinder has the SARGENT logo as shown
in Fig. 6A.
IMPORTANT: Position cylinder so that the
SARGENT logo is positioned correctly.
5. Hand tighten the cylinder clamp screw with Phillips screwdriver to
prevent unscrewing of the cylinder (Fig 6C).
6. Test cylinder function:
•
Key retracts latchbolt and deadbolt (7976 function).
•
Key retracts latchbolt (7978 function).
•
Cylinder not present for 7977 and 7979 functions.
Correct
Incorrect
Fig. 6A
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Outside of Door
Rosette
Spring
Phillips
Screwdriver
Cylinder
Cylinder
Clamp Screw
Fig. 6B
10
1-800-810-WIRE • www.sargentlock.com • A8190B
Fig. 6C
IN100 Mortise Lock
7 Assemble Outside Trim
1. With outside lever horizontal (and handle pointing toward door hinge), insert the mounting posts through
outside of door and lock body.
Make certain the lever spindle is properly engaged inside the lock body (Fig 7A).
2. On the inside of the door, insert spindle into square hole of mortise lock, with spindle slot directed away
from the mortise lock body, and aligned with the set screw hole in the Inside adapter (Fig 7B).
3. Slide inside adapter and plate assembly over spindle and secure with (2) 8-32 X 5/8” Phillips
oval head and lock washer machine screws.
Note: Ensure that position of set screw hole on inside adapter is oriented to match location of hole in
inside lever handle.
Outside of Door
Inside of Door
DPS
Outside Trim
Wire Harness
(From Lock Body)
Fig. 7A Detail
Spindle
Spindle
Outside Trim
Fig. 7A
Fig. 7B
Set Screw Hole
1-800-810-WIRE • www.sargentlock.com • A8190B
11
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Ground Wire
IN100 Mortise Lock
8 Install Inside Rose and Inside Lever Assembly
1. Place inside rose flush against door surface and rotate first counter-clockwise to seat the threads,
then clockwise to securely tighten.
2. Slide lever onto spindle until fully seated. Be sure handle is horizontal and facing the hinge side of
the door. Push lever onto spindle so minimum gap is visible.
3. Tighten the set screw securely with a T20 Torx® driver.
4. Finish securely tightening (2) #12-24 lock body screws.
5. Before closing the door, test that the lever is functional and ensure
smooth operation of the latchbolt.
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Inside of Door
Rose
#12-24 screws
Spindle
Inside Lever
Set Screw
Fig. 8
12
1-800-810-WIRE • www.sargentlock.com • A8190B
IN100 Mortise Lock
9 Install Thumb Turn
1. Insert thumb turn into preparation hole and engage slot in lock body.
2. Orient mounting plate so screw hole is vertical (aligned with preparation holes).
3. Secure plate with Phillips screw provided.
4. Test thumb turn for function by retracting and projecting the deadbolt
(7976 and 7977 functions only).
Inside of Door
Thumb Turn
Phillips
screw
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 9
10 Attach Front Plate
Attach front plate with (2) Phillips head screws.
Outside of Door
(2) Phillips
head screws
1-800-810-WIRE • www.sargentlock.com • A8190B
13
07/31/16
Fig. 10
IN100 Mortise Lock
11 Outside Reader Installation
1. Orient the reader so the LED lens is at the top.
2. Feed the cable/connector through the door (from outside to inside).
3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes.
Hold the reader flush against door while ensuring proper alignment.
Outside of Door
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
LED
Reader Assembly
with Harness
Fig. 11A
14
1-800-810-WIRE • www.sargentlock.com • A8190B
IN100 Mortise Lock
11 Outside Reader Installation (Continued)
4. Feed the reader harness and DPS connectors through the inside mounting assembly
(and gasket if required*). See Figure 11B.
IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 11B, C) - it will damage wires and
the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 11C).
5. Tuck excess cable into wire hole on inside of door.
6. Begin to secure the mounting assembly by partially tightening the (2) through-bolts on the
inside of the door while ensuring proper alignment as you secure the reader (Fig. 11B).
Gasket*
NOTE: Cable lengths exaggerated
for illustrative purposes
Inside
Mounting Plate
Through-bolt
Door Position
Switch (DPS)
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Reader
Harness
Through-bolt
Lock Body
Harness
Ground Ring
Terminal
Inside of Door
Fig. 11C
Fig. 11B
7. Secure ground lug with #6-32 machine screw (Fig.11C).
*Gasket is required for outdoor installations. Do not use gasket for fire-rated openings.
If installing with gasket; separate gasket from mounting plate to feed cables/connectors
through holes as indicated (Fig. 11B).
1-800-810-WIRE • www.sargentlock.com • A8190B
15
07/31/16
Once cables/connectors are fed through, reattach gasket to mounting plate.
IN100 Mortise Lock
11 Outside Reader Installation (Continued)
Installation of Connectors
CAUTION - Do not touch or allow debris to enter connector contacts.
DPS (4-pin)
9-24VDC
Power*
Secure the following connectors to their respective terminals (Fig. 11D):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
Ground
Lug
*NOTE: Optional 2-pin external 9-24VDC power connector.
IMPORTANT: Do not run wires through bottom hole in plate - it will
damage wires and the controller connector.
Route wires around flange, do not route wires through
the flange hole (Fig. 11D, F).
Fig. 11D
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
C. When all connections have been made, tuck excess cable
into wire hole on inside of door.
Fully
tighten
Secure Mounting Plate
D. Secure the mounting assembly while ensuring proper
alignment of outside reader and tighten the (2) through-bolts
on the inside of the door to secure the reader (Fig. 11E).
Fig. 11E
E. Secure the 24-pin card reader connector (Fig. 11F).
Reader
(24-pin)
Board-to-Board
Connector
Fig. 11F
16
1-800-810-WIRE • www.sargentlock.com • A8190B
Lock
Body
(10-pin)
IN100 Mortise Lock
12 Installation of Inside Component Assembly
1. Insert top tabs of controller into slots on mounting plate (Fig. 12).
2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward
door until tab on bottom snaps securely into place on mounting plate.
CAUTION: To avoid possible damage to board-to-board connectors,
care should be taken when securing controller to mounting
plate. If there is resistance when securing, detach controller
to determine cause before re-attaching controller.
Fig. 12
1-800-810-WIRE • www.sargentlock.com • A8190B
17
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Inside of Door
IN100 Mortise Lock
13 Battery Installation
1. Place (6) “AA” alkaline batteries in the compartment, being
careful to align polarity properly (Fig. 13).
2. After batteries are installed, there is a slight delay; then red
and green flash, audible “beep” and lock motor will cycle.
*See Section 8 - LED Indications for more information
AA Batteries (6)
Fig. 13
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
14 Inside Cover Installation
1. Assemble cover by hooking top edge on inside
mounting plate.
2. Carefully press bottom of cover toward door
without pinching or damaging wires.
3. Secure cover utilizing security allen wrench.
Inside of Door
Inside
Cover
Security
Allen Screw
07/31/16
Fig. 14
18
1-800-810-WIRE • www.sargentlock.com • A8190B
IN100 Mortise Lock
Operational Check
For 7976- and 7978-function mortise locks with cylinders:
1. Insert key into cylinder and rotate.
There should be no friction against lock case, wire harness or
any other obstructions.
2. Check that the key retracts the latch:
the key should rotate freely.
3. Throw the deadbolt (if present): Check that the
key retracts both the deadbolt and the latch.
4. Try the inside lever:
Ensure it retracts latch and deadbolt (if provided).
5. Present a valid credential* to unlock outside lever; turn lever to
ensure latch retracts.
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
*Depending upon availability of access control system,
either a (denied) red flash or a green and lock motor
cycle (access granted).
Fig. 15A
Note: The credential should approach the inscription
on the reader as indicated (Fig. 14B) to ensure
that the credential is read properly.
Do not wave credential.
Fig. 15B
1-800-810-WIRE • www.sargentlock.com • A8190B
19
07/31/16
IN100 Mortise Lock
LED Indications
The communication hub has a single LED. It supports an optical scheme with red, green and yellow.
The indication scheme is described by the figures below:
Communication Hub LED indications
Figure 1.
Communication hub normal
operation LED indication
2 sec.
Online
Green
Aperio® lock
offline
EAC offline
Green + one
red flash
Green + two red flashes
Aperio® lock and
EAC offline
Green + three
red flashes
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
UHF
communication
Yellow + off,
fast flash
Some special LED indication schemes* are
used during lock maintenance actions:
2 sec.
Figure 2.
Communication hub maintenance
LED indication
Pairing active
Yellow + green
Ethernet LED indication
The LED on the AH40 communication hub* indicates both the status of
the Ethernet link level and ethernet communication:
2 sec.
Figure 3.
AH40 Communication hub
Ethernet LED indication
Ethernet link
connected
Ethernet
communication
*For more information, refer to Aperio Online Quick Installation Guide
(Document No: ST-001322-PF Date: 2015-12-23)
20
1-800-810-WIRE • www.sargentlock.com • A8190B
Green
Green +
off fast flash
IN100 Mortise Lock
Lock LED indications
The lock has three LEDs. They support an optical scheme of red, yellow and green.
The indication scheme is described by the figures below:
Card access
(configurable)
Access granted,
EAC offline or online
Access denied,
EAC online
Force closed in remote
open/office mode
Busy blink, com hub
busy with other locks
Access denied,
EAC offline
Lock mechanism is
blocked when closing 1)
Error in lock,
maintenance required
Tamper
Enter PIN
One yellow flash after card, two
flashes before PIN (.125 second)
One yellow flash (.25 second)
One green flash
(1 sec.)
One red flash
(1 sec.)
Five yellow flashes and
one red flash (.25 second)
Continuous yellow flashes
(.25 seconds every second)
Three red flashes
(.5 second each)
Continuous red flashes
(.125 seconds every 1 sec.)
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can’t close)
Ten red flashes (.125 sec. each)
repeated every 10 sec.
Time to replace
the battery
Continuous yellow flashes
(.25 seconds every 5 sec.)
Battery reached end
of life, lock disabled
Continuous red flashes (.25
seconds every 5 sec.)
V3 USB cable detection
action occurred
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
EAC response
time
Card + PIN access
(configurable)
Five yellow flashes
(.25 second each)
1) When the lock mechanism is blocked (lock jammed) the lever must be turned to
release the lock mechanism.
Some special LED indication schemes are used during lock maintenance actions:
Figure 5. Lock hub normal
operation LED indication
Enter configuration
mode
Five yellow flashes
(.125 second each)
1-800-810-WIRE • www.sargentlock.com • A8190B
21
07/31/16
Figure 4. Lock normal operation LED
indication
IN100 Mortise Lock
Lock Self-Test LED indication
After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated
using a series of red and green LED flashes as described by the figures below.
LED indication after power up/replacement of the battery
8.3.1
Battery not fully charged
Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at the
right voltage or a backward battery has been installed; battery not fully charged; energy counter
not reset or no Power on self-test done.
Error in lock,
maintenance required
8.3.2
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can’t close)
Test pass
1 red (1s) + 1 green (1s), Power on self-test passed, see table below.
Figure 6. Lock POST LED
indication
8.3.3
One red, one green flash
(1 second)
POST Successful
Test fail
07/31/16
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
1 red (1s) + 3 blinks (500ms, green or red), at least one test failed (red), see table below.
If a fatal error is detected the lock will enter an Error state and continuously indicating
fatal error and will not read cards nor unlock.
1 sec
0.5 sec
0.5 sec
0.5 sec
FATAL ERROR
CABLE ERROR
MECHANICAL ERROR
FATAL ERROR
Tests core functionality - MCUs, memory and
internal communication, etc.
CABLE ERROR
Tests communication between the different
parts in the system, i.e. different boards
connected with a wire.
MECHANICAL ERROR
22
Test related to moving parts of the lock.
1-800-810-WIRE • www.sargentlock.com • A8190B
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-810-WIRE (9473) • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A8190B - 07/16

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00
Create Date                     : 2016:06:28 15:14:36-04:00
Metadata Date                   : 2016:06:28 15:14:48-04:00
Modify Date                     : 2016:06:28 15:14:48-04:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Instance ID                     : uuid:0c69154d-1135-4c60-9b91-abb15b682da6
Original Document ID            : xmp.did:70C65E3111BAE111B42DD5693CF104AB
Document ID                     : xmp.id:71cfcdbd-1041-6b4d-8061-4cb02a2f9ed8
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:2022390b-0a77-6a4b-b6dd-ccdcb783261d
Derived From Document ID        : xmp.did:2022390b-0a77-6a4b-b6dd-ccdcb783261d
Derived From Original Document ID: xmp.did:70C65E3111BAE111B42DD5693CF104AB
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2016:06:28 15:14:36-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 24
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYMCA1

Navigation menu