Installation Instructions
For ML20800 TCWI1 Series
Mortise Lockset
Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
Misalignment can cause premature wear and a lessening of security.
Please read these instructions carefully to prevent missing important steps.
Please Note: Improper installation may result in damage to the lock and void the factory warranty.
FM 335
(Rev. 01/2011)
For installation assistance contact Corbin Russwin Inc., at 1-800-810-WIRE (9473)
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
1 2 3
4
7
5
8
0
6
9
#
*TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
Access 800
TM
1) Warning 1
2) General Description/Specifications/Features 2
3) ML20800 TCAC2 Series Product Illustration 3
4) Installation Instructions 4-10
5) Installation of RF Technology Lock 11
6) Operational Check 12
Table of Contents
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that the interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced TV technician for help
This Class B digital apparatus complies with Canadian ICES-003.
Warning: To comply with “Fire Listed” doors, only alkaline batteries must be used.
Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
1) Warning
1
7.1) Important 13
7.2) Installation Notes 13
7.3) Electrolynx™ Connector System 13
7.4) ML20800 TCAC2 Series Illustration with M861 Harness 14
7.5) M861 Forced Door Propped Door Option 15
7.6) M35 Power/Remote Unlocking 16
7) ML20800 TCAC2 Hard Wiring Instructions for Mortise 13
7.7) M35 Power/Remote Unlocking with M861 Forced
Door Propped Door Option
17
Page
1) Warning ....................................................................................................... 1
2) General Descriptions/Specifications/Features ......................................... 2
3) ML20800 Series Product Illustration ....................................................... 3
4) Installation Instructions .......................................................................... 4-10
5) Operational Check .... ............................................................................... 11
6) Hard Wiring Instructions ..................................................................... 12-13
6.1) Important ............................................................................................ 12
6.2) Installation Notes ................................................................................ 12
6.3) ElectrolynxTM Connector System Notes ............................................. 12
6.4) Hard Powered Connections ................................................................. 13
2
General Description
The Corbin Russwin Access 800 TCWI1 0RUWLVH Lock is designed for applications requiring
wireless access control. The TCWI1 is a self-contained microprocessor-controlled access control
product with non-volatile memory. It is able to utilize the existing wireless LAN 802.11 b/g in order
to communicate with the access control system. The TCWI1 lock will hold a total of 2000 different
user codes. This product is operated by six (6) "AA" alkaline batteries or by Corbin Russwin 784
9VDC power supply. Corbin Russwin 0RUWLVH locks are designed with quality components to
provide high security, performance and durability.
Specifications
• Latch 6WDLQOHVV6WHHO /RFNLQJVLGHFRQWUROOHGE\DQ\FRPELQDWLRQ
RINH\SDGSUR[FDUGRUF\OLQGHURYHUULGH
1RQORFNLQJVLGHOHYHUUHWUDFWVODWFKDQG
'HDGEROW6WDLQOHVV6WHHO
GHDGEROW
$X[LOLDU\/DWFK6WDLQOHVV6WHHOQRQKDQGHG
+DQGLQJ(DVLO\ILHOGUHYHUVLEOHZLWKRXW
GLVDVVHPEOLQJWKHORFNERG\/RFNVIXUQLVKHGIRUGRRUV&DQEH
&DVHJDXJHKHDY\GXW\ZURXJKWVWHHOIXUQLVKHGIRURWKHUGRRUVL]HVXSRQUHTXHVW
8//LVWHGKU&RQVXOW)DFWRU\
Features
WiFi 802.11 b/g enabled
2000 Users per lock (more possible with software)
10,000 Event audit trail
• Centralized lock management
Real Time Door Status Monitoring
(Only applies when unit is hard powered)
Easy Installation
HID Prox Compatible (125kHz 26-39 Bit)
2) General Descriptions/ Specifications/ Features
3
3) ML20800 Series Product Illustration
Verify Hand and Bevel of door. Illustrations shown are as viewed from the outside
or secure side of opening.
1
4) Installation Instructions
3
2
4
Prep door according to supplied Corbin Russwin Inc. door marker.
FOR
USE
ON
FIRE
DOOR
NOT
Left Hand
Hinges Left.
Open Inward.
"LH"
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
"LHR"
Right Hand
Hinges Right.
Open Inward.
"RH"
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
"RHR"
7/8"
1-1/2
1/8" Dia. holes
(2) required
Fire Stop Plate required
for fire rated doors
Slot
Attach Fire Stop Plate
Using self tapping screws
#8-32x1/2 long for wood &
metal doors
.C of 1-1/2 Dia
L
Outside
of Door
Hole for ribbon cable
Non Fire Rated Exterior Doors
install weather conduit.
(Hollow Doors Only)
Outside
of Door
Non Fire Rated Door
Hole for
ribbon cable
Install conduit half with recessed
panel "Not For Use On Fire Door"
visible from outside of door.
The Optional Conduit is available
for Non Fire rated doors to provide
weather protection for exterior door
applications. It is included in the M99
Weatherseal Gasketing Kit when
ordered with the device. If ordered
separately, order part number
794F929.
Lock Assembly Instructions
Align bevel accordingly. Engage 7/64 Allen wrench on to cap screw required for step 2
page 6. Feed connector and wires through 1 (25) dia. wire access hole. Insert lockbody
into mortised cutout in door and hold loosely in place with (2) #12x1" lockbody screws.
3
Installation Instructions
5
(2) #12x1"
combination screws
Lockbody
7/64 Allen Wrench
Inside
of Door
Feed connectors & wires
through wire access hole
4
6
Spindles
Keypad ribbon cable
Outside
of Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon
through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon
through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain
the lever spindle is properly engaged in lock. (see diagram and Note A. below)
Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct
position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.)
the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the
locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody
screws. Remove Allen wrench.
Installation Instructions
Ground
wire
Gasket (optional)
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
NOTE: Key and
cylinder must be
rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:
Peel off the adhesive protective paper from
gasket. Feed Trim assembly motor harness
through gasket opening as shown and firmly
press gasket to escutcheon, aligning edge of
gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a
device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately,
order part number 794F929. The gaskets may be used as a seal between the escutcheon
and the door surfaces.
NOTE A.
For MUSÉO Lever
collections ONLY.
Rotate adapter
bushing as needed
to insure horizontal
lever position and
maximum thread
engaging lever -
adapter bushing.
Lever
Lever
5
7
Motor connector
Ground Terminal
Red & Black wires
Keypad ribbon
cable
Locate (3) oval head screws
and insert through the
Escutcheon and thread
into the outside Escutcheon.
Ground
Wire
Keypad harness
(ribbon cable)
Remote Power
Connector
(M35 Remote Power
Wiring Harness also
available as part
No. 793F069)
Tu
Inside
of door
Turnpiece
Installation of Inside Escutcheon
NOTE: Connectors go on only one way. Do not offset connector and be sure they are completely seated.
1. Remove black battery cover from the eschutcheon with High Security T20 Trox bit provided.
2. Connect Ground wire to Ground terminal, Keypad ribbon cable connector to controller, lockbody
harness to motor connector, DPS conector on lockbody harness to remote power and DPS harness, and
connect remote power if applicable.
3. Align turnpiece to the vertical position.
4. Push excess keypad ribbon cable into the ribbon cable hole.
Installation Instructions
Controller
Turnpiece male switch
1
Male turnpiece
switch connector
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
Lockbody Harness
Lockbody
Harness
Gasket
GASKET APPLICATION:
Peel off the adhesive protective paper from
gasket. Feed Trim assembly motor harness
through gasket opening as shown and firmly
press gasket to escutcheon, aligning edge of
gasket with the edge of the escutcheon.
Lockbody
Harness
Motor connector
Keypad harness
(ribbon cable)
Ground Terminal
Remote power
DPS
Remote power
and DPS
5
8
Installation Instructions
Installation of Inside Escutcheon (continued)
CAUTION: Do not allow lockbody harness wires to enter cylinder hole in lockbody. Wire
damage and/or malfunction of the lock may occur.
1. Turn inside lever to the horizontal position and rotate the turnpiece to the vertical position. Slide
onto spindle halfway. With inside escutcheon resting on spindle, be certain that all keypad ribbon
cable will remain inside ribbon cable hole, and that ground wire will not get pinched once
escutcheon is mounted. Escutcheon will not fit flush on door otherwise.
2. Insert 3 #10-24 screws through inside escutcheon and thread loosely into outside escutcheon. Check
operation of both inside and outside levers and make sure the turnpiece and key still operate the
latch and deadbolt correctly. If lock function is satisfactory, fully tighten the bottom two screws.
Check operation of both levers again. If levers move freely, tighten top screw. If levers do not move
freely, loosen bottom screws and realign the escutcheons until proper operation is obtained.
Inside
of door
Lockbody harness - Feed excess
wire back into the mortise of the
door between the door cavity and
lockbody. Do not feed excess
wires into the cylinder hole of
the lock.
6
Installation Instructions
9
Installation of Armored Front Plate
1.Install armored front plate using two #8-32 x 1/4"screws provided.
Lockbody screws
Front Plate
screws
Armored Front Plate
7
Installation Instructions
Battery Polarity
10
Tabs Retaining Slots
Security Screw
Battery Keeper
Bottom Tabs
Top Tab
Battery Installation
1. Remove battery keeper by lifting top tab and pulling away from the unit.
2. Install (6) AA Batteries into controller compartment being careful to align +/- polarity
properly.
3. Install Battery Keeper by first inserting bottom tabs in bottom slots of controller. Lift the
top tab over batteries and snap into position.
4. Attach battery cover to inside controller escutcheon making sure to line up tabs with
retaining slots in battery cover. Secure with security screw using security T20 bit.
T20 bit
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
5) Operational Check
8
11
Lock Operational Check For devices with cylinders:
1. Insert key into cylinder and rotate. (There should be no friction against lock case, wire
harness or any other obstructions)
2. The key will retract the latch, key should rotate freely. If the deadbolt is thrown, the key will
first retract the deadbolt and then the latch. Inside lever retracts latch and deadbolt, if
provided.
3.8VH3UR[LPLW\&DUGRU3LQFRGHVHWXSZLWK/RFN&RQILJXUDWLRQ7RRO7KLVVKRXOGXQORFN
RXWVLGHOHYHUDQGDOORZODWFKWREHUHWUDFWHG3OHDVHVHH1HWZRUN/RFN&RQILJXUDWLRQ
7RRO8VHU0DQXDO:)01IRUPRUHLQIRUPDWLRQ
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
Corbin Russwin, Inc. Technical Product Support:
225 Episcopal Road Corbin Russwin, Inc.
Berlin, CT 06037-4004 Phone 800-810-WIRE (9473)
www.corbinrusswin.com
copyright 2007
Canada: Assa Abloy DSS Canada
160 Four Valley Drive
Vaughun, ONT L4K 4TG
www.yalecorbin.on.ca
6) ML20800 Hard Wiring Instructions
12
1. Caution: disconnect all input power before beginning installation to prevent
electrical shock and equipment damage.
2. Installer must be a trained, experienced service person.
3. All wiring must comply with applicable local electrical codes, ordinances
and regulations.
6.1) Important
1. With new applications, an ElectroLynx™ door harness with 8 and 4 pin connectors
will be pre-installed inside door by ASSA ABLOY door manufacturer when specified
during ordering process.
2. Wiring to pigtail harness is per facility wiring requirement. ElectroLynx™ connector
terminations and wire colors all match.
3. If door does not have an ElectroLynx™ type door harness, cut connectors off
product and hard wire, or consult factory for appropriate mating harness.
6.2) Installation Notes
The system is designed to be installation friendly with pluggable connectors from the
electric hinge through the door to the rail. The only wiring required is to the loose wires
on the pigtail harness assembly on the frame side of the electric hinge.
IMPORTANT:
The plug and receptacle connectors are designed to mate and lock together as shown
in the figure. Plug the connectors into each other with the locking mechanism aligned
as indicated.
Do NOT Force connectors on any other way.
6.3) ElectroLynx™ Connector System Notes:
As part of their promise to provide
innovative, fast and effective, and higher
security solutions to their customers,
ASSA ABLOY Group companies offer
ElectroLynx™, a universal quick-connect
system that simplifies the electrification of
the door opening.
ElectroLynx™ is a registered trademark of
ASSA ABLOY North America, Inc.
Receptacle
Locking Mechanism
Plug
Hardwiring Made Easy
ELECTRO
TM
6) ML20800 Hard Wiring Instructions
13
ELECTRO
6.4) Hard Powered Connections
END OF INSTALLATION INSTRUCTIONS