ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX Exhibit Cover

ASSA ABLOY Inc. Microprocessor Controlled Networked Locks XX XXXX Exhibit Cover

Contents

Manual 1 of 3

Download: ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX   Exhibit Cover
Mirror Download [FCC.gov]ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX   Exhibit Cover
Document ID1434414
Application ID/QxprcOsA3EX13m/9ZWA7w==
Document DescriptionManual 1 of 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize144.54kB (1806701 bits)
Date Submitted2011-03-21 00:00:00
Date Available2011-03-21 00:00:00
Creation Date2011-02-24 20:59:56
Producing SoftwareAdobe Acrobat 9.1.1
Document Lastmod2011-02-24 20:59:56
Document TitleMicrosoft Word - XX-XXXX - Exhibit Cover
Document CreatorAdobe Acrobat 9.1.1
Document Author: Kirby.Munroe

Certification Exhibit
FCC ID: U4A-SCYPROX3
IC: 6982A-SCYPROX3
FCC Rule Part: 15.209
IC Radio Standards Specification: RSS-210
ACS Report Number: 10-0443.W06.11.A
Manufacturer: Assa Abloy
Model: S1-PA/PK, S2-PA/PK,
TCIP1-M802/M803, TCWI1-M802/M803
Manual(s)
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Access 800
TM
Installation Instructions
For ML20800 TCWI1 Series
Mortise Lockset
FM 335
(Rev. 01/2011)
Please read these instructions carefully to prevent missing important steps.
Please Note: Improper installation may result in damage to the lock and void the factory warranty.
Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
Misalignment can cause premature wear and a lessening of security.
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
For installation assistance contact Corbin Russwin Inc., at 1-800-810-WIRE (9473)
Table of Contents
1) Warning
2) General Description/Specifications/Features
Page 2
1)3)Warning
.......................................................................................................
1 3
ML20800
TCAC2 Series Product Illustration
2)4)General
Descriptions/Specifications/Features
......................................... 2 4-10
Installation
Instructions
3) ML20800 Series Product Illustration ....................................................... 3
5) Installation of RF Technology Lock
11
4) Installation Instructions .......................................................................... 4-10
Operational
Check
5)6)Operational
Check
.... ............................................................................... 11 12
6)7)Hard
WiringTCAC2
Instructions
12-1313
ML20800
Hard .....................................................................
Wiring Instructions for Mortise
6.1) Important ............................................................................................ 12
7.1) Important
6.2)
Installation Notes ................................................................................ 12 13
7.2)Electrolynx
Installation TM
Notes
6.3)
Connector System Notes ............................................. 12 13
7.3)Hard
Electrolynx™
System
6.4)
PoweredConnector
Connections
................................................................. 13 13
7.4) ML20800 TCAC2 Series Illustration with M861 Harness
14
7.5) M861 Forced Door Propped Door Option
15
7.6) M35 Power/Remote Unlocking
16
7.7) M35 Power/Remote Unlocking with M861 Forced
17
Door Propped Door Option
1) Warning
Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that the interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced TV technician for help
This Class B digital apparatus complies with Canadian ICES-003.
Warning: To comply with “Fire Listed” doors, only alkaline batteries must be used.
2) General Descriptions/ Specifications/ Features
General Description
The Corbin Russwin Access 800 TCWI1 0RUWLVH Lock is designed for applications requiring
wireless access control. The TCWI1 is a self-contained microprocessor-controlled access control
product with non-volatile memory. It is able to utilize the existing wireless LAN 802.11 b/g in order
to communicate with the access control system. The TCWI1 lock will hold a total of 2000 different
user codes. This product is operated by six (6) "AA" alkaline batteries or by Corbin Russwin 784
9VDC power supply. Corbin Russwin 0RUWLVH locks are designed with quality components to
provide high security, performance and durability.
Specifications
• Latch 6WDLQOHVV6WHHO
• /RFNLQJVLGHFRQWUROOHGE\DQ\FRPELQDWLRQ
• 'HDGEROW6WDLQOHVV6WHHO
RINH\SDGSUR[FDUGRUF\OLQGHURYHUULGH
• 1RQORFNLQJVLGHOHYHUUHWUDFWVODWFKDQG
• $X[LOLDU\/DWFK6WDLQOHVV6WHHOQRQKDQGHG
GHDGEROW
• +DQGLQJ(DVLO\ILHOGUHYHUVLEOHZLWKRXW
GLVDVVHPEOLQJWKHORFNERG\‡/RFNVIXUQLVKHGIRUGRRUV&DQEH
‡&DVHJDXJHKHDY\GXW\ZURXJKWVWHHOIXUQLVKHGIRURWKHUGRRUVL]HVXSRQUHTXHVW
‡8//LVWHG KU  &RQVXOW)DFWRU\ 
Features
• WiFi 802.11 b/g enabled
• 2000 Users per lock (more possible with software)
• 10,000 Event audit trail
• Centralized lock management
• Real Time Door Status Monitoring
(Only applies when unit is hard powered)
• Easy Installation
• HID Prox Compatible (125kHz 26-39 Bit)
3) ML20800 Series Product Illustration
4) Installation Instructions
Verify Hand and Bevel of door. Illustrations shown are as viewed from the outside
or secure side of opening.
Left Hand
Hinges Left.
Open Inward.
"LH"
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
"LHR"
Right Hand
Hinges Right.
Open Inward.
"RH"
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
"RHR"
2 Prep door according to supplied Corbin Russwin Inc. door marker.
Outside
of Door
Hole for ribbon cable
7/8"
1/8" Dia. holes
(2) required
Fire Stop Plate required
for fire rated doors
CL of 1-1/2 Dia.
Slot
1-1/2
Attach Fire Stop Plate
Using self tapping screws
#8-32x1/2 long for wood &
metal doors
The Optional Conduit is available
for Non Fire rated doors to provide
weather protection for exterior door
applications. It is included in the M99
Weatherseal Gasketing Kit when
ordered with the device. If ordered
separately, order part number
794F929.
Hole for
ribbon cable
Non Fire Rated Exterior Doors
install weather conduit.
(Hollow Doors Only)
NO
FO
USE ON FIRE
DO
Outside
of Door
OR
Install conduit half with recessed
panel "Not For Use On Fire Door"
visible from outside of door.
Non Fire Rated Door
Installation Instructions
Lock Assembly Instructions
Align bevel accordingly. Engage 7/64 Allen wrench on to cap screw required for step 2
page 6. Feed connector and wires through 1 (25) dia. wire access hole. Insert lockbody
into mortised cutout in door and hold loosely in place with (2) #12x1" lockbody screws.
7/64 Allen Wrench
Inside
of Door
Lockbody
Feed connectors & wires
through wire access hole
(2) #12x1"
combination screws
Installation Instructions
Installation of Outside Escutcheon
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a
device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately,
order part number 794F929. The gaskets may be used as a seal between the escutcheon
and the door surfaces.
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon
through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon
through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain
the lever spindle is properly engaged in lock. (see diagram and Note A. below)
Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct
position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.)
the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the
locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody
screws. Remove Allen wrench.
Outside
of Door
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
Keypad ribbon cable
Gasket (optional)
Ground
wire
NOTE A.
For MUSÉO Lever
collections ONLY.
Rotate adapter
bushing as needed
to insure horizontal
lever position and
maximum thread
engaging lever adapter bushing.
Spindles
Use Correct Spindle Orientation
STANDARD
Lever
MUSÉO
Lever
GASKET APPLICATION:
Peel off the adhesive protective paper from
gasket. Feed Trim assembly motor harness
through gasket opening as shown and firmly
press gasket to escutcheon, aligning edge of
gasket with the edge of the escutcheon.
NOTE: Key and
cylinder must be
rotated as shown
Correct
Incorrect
Installation Instructions
Installation of Inside Escutcheon
NOTE: Connectors go on only one way. Do not offset connector and be sure they are completely seated.
1. Remove black battery cover from the eschutcheon with High Security T20 Trox bit provided.
2. Connect Ground wire to Ground terminal, Keypad ribbon cable connector to controller, lockbody
harness to motor connector, DPS conector on lockbody harness to remote power and DPS harness, and
connect remote power if applicable.
3. Align turnpiece to the vertical position.
4. Push excess keypad ribbon cable into the ribbon cable hole.
Motor connector
Motor connector
Lockbody
Harness
Keypad harness
Keypad
harness
(ribbon
cable)
(ribbon cable)
Ground Terminal
Ground Terminal
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
Remote
power
Remote
Power
and DPS
Connector
(M35 Remote Power
Wiring Harness also
available as part
No. 793F069)
Remote power
Turnpiece
DPS Harness
Lockbody
Red & Black wires
Gasket
Controller
Turnpiece male switch
Inside
of door
Keypad ribbon
cable
Ground
Wire
Lockbody
Harness
Male turnpiece
switch connector
Locate (3) oval head screws
and insert through the
Escutcheon and thread
into the outside Escutcheon.
Tu
GASKET APPLICATION:
Peel off the adhesive protective paper from
gasket. Feed Trim assembly motor harness
through gasket opening as shown and firmly
press gasket to escutcheon, aligning edge of
gasket with the edge of the escutcheon.
Installation Instructions
Installation of Inside Escutcheon (continued)
CAUTION: Do not allow lockbody harness wires to enter cylinder hole in lockbody. Wire
damage and/or malfunction of the lock may occur.
1. Turn inside lever to the horizontal position and rotate the turnpiece to the vertical position. Slide
onto spindle halfway. With inside escutcheon resting on spindle, be certain that all keypad ribbon
cable will remain inside ribbon cable hole, and that ground wire will not get pinched once
escutcheon is mounted. Escutcheon will not fit flush on door otherwise.
2. Insert 3 #10-24 screws through inside escutcheon and thread loosely into outside escutcheon. Check
operation of both inside and outside levers and make sure the turnpiece and key still operate the
latch and deadbolt correctly. If lock function is satisfactory, fully tighten the bottom two screws.
Check operation of both levers again. If levers move freely, tighten top screw. If levers do not move
freely, loosen bottom screws and realign the escutcheons until proper operation is obtained.
Inside
of door
Lockbody harness - Feed excess
wire back into the mortise of the
door between the door cavity and
lockbody. Do not feed excess
wires into the cylinder hole of
the lock.
Installation Instructions
6 Installation of Armored Front Plate
1.Install armored front plate using two #8-32 x 1/4"screws provided.
Lockbody screws
Armored Front Plate
Front Plate
screws
Installation Instructions
Battery Installation
1. Remove battery keeper by lifting top tab and pulling away from the unit.
2. Install (6) AA Batteries into controller compartment being careful to align +/- polarity
properly.
3. Install Battery Keeper by first inserting bottom tabs in bottom slots of controller. Lift the
top tab over batteries and snap into position.
4. Attach battery cover to inside controller escutcheon making sure to line up tabs with
retaining slots in battery cover. Secure with security screw using security T20 bit.
Top Tab
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
Battery Keeper
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
Bottom Tabs
Battery Polarity
Tabs
Retaining Slots
Security Screw
T20 bit
10
5) Operational Check
Lock Operational Check For devices with cylinders:
1. Insert key into cylinder and rotate. (There should be no friction against lock case, wire
harness or any other obstructions)
2. The key will retract the latch, key should rotate freely. If the deadbolt is thrown, the key will
first retract the deadbolt and then the latch. Inside lever retracts latch and deadbolt, if
provided.
3.8VH3UR[LPLW\&DUGRU3LQFRGHVHWXSZLWK/RFN&RQILJXUDWLRQ7RRO7KLVVKRXOGXQORFN
RXWVLGHOHYHUDQGDOORZODWFKWREHUHWUDFWHG3OHDVHVHH1HWZRUN /RFN&RQILJXUDWLRQ
7RRO8VHU0DQXDO :)01 IRUPRUHLQIRUPDWLRQ
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
Corbin Russwin, Inc.
225 Episcopal Road
Berlin, CT 06037-4004
www.corbinrusswin.com
copyright 2007
Technical Product Support:
Corbin Russwin, Inc.
Phone 800-810-WIRE (9473)
11
Canada: Assa Abloy DSS Canada
160 Four Valley Drive
Vaughun, ONT L4K 4TG
www.yalecorbin.on.ca
6) ML20800 Hard Wiring Instructions
6.1)
Important
6.2)
Installation Notes
6.3)
ElectroLynx™ Connector System Notes:
1. Caution: disconnect all input power before beginning installation to prevent
electrical shock and equipment damage.
2. Installer must be a trained, experienced service person.
3. All wiring must comply with applicable local electrical codes, ordinances
and regulations.
1. With new applications, an ElectroLynx™ door harness with 8 and 4 pin connectors
will be pre-installed inside door by ASSA ABLOY door manufacturer when specified
during ordering process.
2. Wiring to pigtail harness is per facility wiring requirement. ElectroLynx™ connector
terminations and wire colors all match.
3. If door does not have an ElectroLynx™ type door harness, cut connectors off
product and hard wire, or consult factory for appropriate mating harness.
The system is designed to be installation friendly with pluggable connectors from the
electric hinge through the door to the rail. The only wiring required is to the loose wires
on the pigtail harness assembly on the frame side of the electric hinge.
IMPORTANT:
The plug and receptacle connectors are designed to mate and lock together as shown
in the figure. Plug the connectors into each other with the locking mechanism aligned
as indicated.
Do NOT Force connectors on any other way.
Locking Mechanism
TM
ELECTRO
Receptacle
Hardwiring Made Easy
As part of their promise to provide
innovative, fast and effective, and higher
security solutions to their customers,
ASSA ABLOY Group companies offer
ElectroLynx™, a universal quick-connect
system that simplifies the electrification of
the door opening.
Plug
ElectroLynx™ is a registered trademark of
ASSA ABLOY North America, Inc.
12
6) ML20800 Hard Wiring Instructions
6.4)
Hard Powered Connections
ELECTRO
END OF INSTALLATION INSTRUCTIONS
13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Kirby.Munroe
Create Date                     : 2011:02:24 20:59:56-05:00
Modify Date                     : 2011:02:24 20:59:56-05:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2011:02:24 20:59:56-05:00
Creator Tool                    : Adobe Acrobat 9.1.1
Format                          : application/pdf
Title                           : Microsoft Word - XX-XXXX - Exhibit Cover
Creator                         : Kirby.Munroe
Document ID                     : uuid:92b67d9b-4d54-492d-aaf3-62ae1205b4df
Instance ID                     : uuid:672091da-a861-4943-8c7d-fdb614797454
Producer                        : Adobe Acrobat 9.1.1
Page Count                      : 15
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYPROX3

Navigation menu