ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX Exhibit Cover

ASSA ABLOY Inc. Microprocessor Controlled Networked Locks XX XXXX Exhibit Cover

Contents

Manual 3 of 3

Download: ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX   Exhibit Cover
Mirror Download [FCC.gov]ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX   Exhibit Cover
Document ID1434416
Application ID/QxprcOsA3EX13m/9ZWA7w==
Document DescriptionManual 3 of 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize235.96kB (2949533 bits)
Date Submitted2011-03-21 00:00:00
Date Available2011-03-21 00:00:00
Creation Date2011-02-24 20:57:31
Producing SoftwareAdobe Acrobat 9.1.1
Document Lastmod2011-02-24 20:57:31
Document TitleMicrosoft Word - XX-XXXX - Exhibit Cover
Document CreatorAdobe Acrobat 9.1.1
Document Author: Kirby.Munroe

Certification Exhibit
FCC ID: U4A-SCYPROX3
IC: 6982A-SCYPROX3
FCC Rule Part: 15.209
IC Radio Standards Specification: RSS-210
ACS Report Number: 10-0443.W06.11.A
Manufacturer: Assa Abloy
Model: S1-PA/PK, S2-PA/PK,
TCIP1-M802/M803, TCWI1-M802/M803
Manual(s)
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
v.S2
Profile
WiFi Mortise Lock
Installation Instructions
A7786E
01/11
Copyright 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
Table of Contents
Warning . ..................................................................................2
General Description..................................................................3
Hardware Specifications..........................................................3
Electronic Specifications..........................................................3
Installation Wiring Overview....................................................3
Lock Wiring...............................................................................4
Parts Breakdown......................................................................5
Installation Instructions...........................................................7
Operational Check .................................................................15
Warning
Warning: Changes or modifications to this unit not expressly approved by ASSA
ABLOY Inc. could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Industry Canada:
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications
were met.
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant desrèglements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui
peut causer l’opération peu désirée.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries
only.
SARGENT Mfg. Co. v.S Series locksets utilizing a door position switch (DPS) are not rated
for,
or intended for use in life safety applications.
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
FCC:
1-800-810-WIRE • www.sargentlock.com • A7786E
Profile Series v.S2 WiFi Mortise Lock
General Description
The SARGENT Profile Series v.S2 mortise lock is available with either an HID® 125 kHz prox or 13.56 MHz
iCLASS® technology reader. It is designed for applications requiring wireless access control. The v.S2 is a
self-contained microprocessor-controlled access control product with non-volatile memory. It is able to utilize
the existing wireless LAN (802.11b/g) in order to communicate with the access control system. The v.S2 lock
holds a total of 2400 unique users per lock.
This product is operated by six (6) “AA” alkaline batteries or a SARGENT 3267 9VDC power supply. SARGENT
mortise locks are designed with quality components to provide high security, performance and durability.
The Profile Series v.S2 mortise lock may be used for both indoor and exterior applications. A weatherprotective gasket (provided with unit) is recommended for exterior applications.
HID® and iCLASS® are registered trademarks of HID Global Corporation.
• Latch: One-piece stainless steel, 3⁄4" projection
• Deadbolt: One-piece hardened stainless steel
• Guardbolt: Stainless steel, non-handed
• Handed: Easily field reversible without
opening case
Electronic Specifications
• Wireless (WiFi 802.11 b/g) online,
battery-operated
• 2400 users per lock
• 10,000 Event audit trail
• Centralized lock management
• Case: 12-gauge, heavy duty wrought steel
• Door Status Monitoring*
• Locks furnished for 1-3/4” doors. Can be
furnished for other door sizes upon request.
Consult factory.
• Easy installation (no need to hardwire)
• UL Listed (3 hours)
• Lockdown capable*
• Inside lever retracts latch and deadbolt
• Supports HID® 125 kHz prox or 13.56
MHz iCLASS® credentials (26 - 39 bit);
supports CSN reads for other common
13.56 MHz cards, including MiFare, DesFire, and Felica
Installation Wiring Overview
• Supports most current WiFi networks
security standards
SARGENT Profile Series WiFi
v.S2 Typical Application
• For specific security information, please
contact a local ASSA ABLOY Door Security Solutions sales consultant or call
800-810-WIRE
• Input Power: DC 9V, 1.5A (6 AA alkaline
batteries or optional hard-powered)
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Hardware Specifications
* Lockdown and real-time door status
monitoring available only when lock is
hard-powered
Internal
Building
Network (Intranet)
802.11b/g Wireless Network Device
Ethernet LAN
Network
Interface
Card
v.S2 Lock
Lock Management
Tool (LMT)
1-800-810-WIRE • www.sargentlock.com • A7786E
01/29/11
8
(+) 9VDC (RED)
(-) (BLACK)
AX/DPS NC (PINK)
AX/DPS COM (VIOLET)
Unused
Unused
Unused
EGND (GREEN)
TB1
DX NC (GREEN/WHITE)
RX COM (WHITE)
RX NC (GREEN)
DX (WHITE/BLACK)
LX NO (RED/YELLOW)
LX COM (RED/GREEN
Motor B (BLACK)
Motor A (RED)
E1
Ring Terminal
From Trim
1-800-810-WIRE • www.sargentlock.com • A7786E
From
Lock Body
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
01/29/11
Profile Series v.S2 WiFi Mortise Lock
Lock Wiring
Controller Board Connectors
(Inside Escutcheon)
TB2
DPS
DPS
Power
16
12
11
13
15
15
14
1-800-810-WIRE • www.sargentlock.com • A7786E
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
01/29/11
Profile Series v.S2 WiFi Mortise Lock
Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS
10
Profile Series v.S2 WiFi Mortise Lock
Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS, continued
ITEM
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
QTY.
Outside Lever
Reference 8200 Catalog for available levers
Inside Lever
Reference 8200 Catalog for available levers
82-0493
O/S Escutcheon only with Cylinder
82-0495
O/S Escutcheon only without Cylinder
82-0492
Inside Escutcheon only without Thumb Turn
82-4571
Inside Escutcheon only with Thumb Turn
52-2431
125 kHz Prox Only Bezel Assembly (PA)
52-2432
Keypad and 125 kHz Prox Bezel Assembly (PK)
01/29/11
DESCRIPTION
OR
52-4422
13.56 MHz Prox Only Assembly (S2-IA)
52-4423
Keypad and 13.56 MHz iCLASS Bezel Assembly (S2-IK)
52-4425
S2 Controller Assembly (Double Pulse)
52-3855
Battery Cover Assembly
01-1212
Security Screw
52-2427
Profile Screw Pack - Specify Finish (Includes: Fire Stop Plate,
Trim Mounting Screws, Security Allen Wrench)
10
Consult Factory
Lever Handle Screw (Depends on Lever Style)
11
Consult Factory
Inside Adapter Assembly (Depends on Lever Style)
12
Consult Factory
Outside Adapter Assembly (Depends On Lever Style)
13
14
15
16
PART NO.
S2-82276-hand-finish
Lockbody with Deadbolt with Cylinder
S2-82277-hand-finish
Lockbody with Deadbolt without Cylinder
S2-82278-hand-finish
Lockbody without Deadbolt with Cylinder
S2-82279-hand-finish
Lockbody without Deadbolt without Cylinder
82-0084
Faceplate with Deadbolt (shown)
82-0081
Faceplate without deadbolt
77-4336
Mortise Screw Pack - Specify Finish (Includes: Wood and Metal Lock body Screws, Faceplate Screws, and Strike Screws)
#43 Mortise Cylinder
Consult Factory
1-800-810-WIRE • www.sargentlock.com • A7786E
Profile Series v.S2 WiFi Mortise Lock
Installation Instructions
Step #1 – Door Preparation
A. Verify Hand and Bevel of Door
Stand on outside/locked side of door when determining the door hand.
LH
Left Hand
Hinges Left
Open Inward
LHRB
Left Hand
Reverse Bevel
Hinges Left
Open Outward
RH
Right Hand
Hinges Right
Open Inward
RHRB
Right Hand
Reverse Bevel
Hinges Right
Open Outward
Fig. 1A
B. Door Preparation
Prior to installation, all holes must be free of burrs, debris and sharp edges.
Prepare door according to appropriate template (see website www.intelligentopenings.com):
Outside of Door
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Door Manufacturing Template: 4533
Inside of Door
Through-bolt Hole
Through-bolt Hole
Ribbon Cable Hole
(Controller to Keypad)
Ribbon Cable Hole
(Controller to Keypad)
Inside of Lockbody Wire Hole
Outside Cylinder Hole
(only with cylinder installation)
Thumb Turn Lever Hole
Lever Handle Hole
Lever Handle Hole
Mortised
Pocket
Pre-drilled and/or
Tapped Holes
Fig. 1B
1-800-810-WIRE • www.sargentlock.com • A7786E
01/29/11
Profile Series v.S2 WiFi Mortise Lock
Step #2 – How to Change Hand of Lockbody
A. Reverse Lock Hand
Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A):
1. Position lock body with red surface of locking piece visible.
2. Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body.
3. Rotate the locking piece 180° until RED surface is
on opposite side.
Connector
Note: Red indicates locked side (outside).
Wire harness MUST exit through the
inside/non-cylinder side of the lockbody.
Slot
B. Retaining Ring
Make sure the plastic retaining ring is seated
correctly (Fig. 2B):
1. The wires and the plastic retaining ring must
be located on the non-cylinder side.
2. Orient the plastic retaining ring so that the word
Bottom is located at the bottom of the cylinder hole.
Plastic
Retaining
Ring
3. Route the wires from the top of the cylinder hole
into the slot on the top of the plastic retaining ring,
NOT through the retaining ring.
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Red Locking Piece
Indicates Locked Side
Right Hand Shown
Fig. 2B
Outside of Door
Locking
Guide
Slot
Push In
Fig. 2A
C. Reverse Latch Hand
Beveled surface of latchbolt must face strike (Fig. 2C).
The deadlatch is self adjusting.
To change the hand of the latchbolt:
1. Insert the blade of a slotted screwdriver (>1/4")
into the spade shape slot behind latch.
2. Rotate the screwdriver 90° to push latchbolt out
until back of bolt clears lock case front.
3. Rotate latchbolt 180° until the latchbolt
drops back into the lockbody.
Note: Latch cannot be unscrewed.
1-800-810-WIRE • www.sargentlock.com • A7786E
Fig. 2C
Profile Series v.S2 WiFi Mortise Lock
Step #3 – Install Lockbody
To install lockbody:
1. Feed the wires first through the mortise pocket
and out the inside prep, followed by the lockbody (Fig. 3A).
Note: Connectors and wires must be fed
through non-cylinder side.
2. The wires from the lockbody exit the inside door
prep through the mortise cutout.
3. Loosely secure the lockbody in the door with
two #12 x 1-1/4" wood screws or #12-24 x 1/2"
machine screws.
Note: Do not completely tighten at this time.
Mortise
Connectors
(2) #12-24 x 1/2" Long
Flat Head Screws
for Metal Doors
Inside of Door
Fig. 3A
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
(2) #12 x 1-1/4” Long
Flat Head Screws
for Metal Doors
Step #4 – Door Options
A. Fire Stop Plate (P/N 52-0033)
(2) 1/8” Diameter
Holes Required
Fire-rated doors require a fire
stop plate on the outside of the
door (Fig. 4A).
Fire Stop Plate
1. Drill (2) 1/8" x 1-1/4" deep holes
in the door if not already present.
Refer to template for fire-stop
prep locations.
(2) #8 Self-Tapping
Screws for Wood
and Metal Doors
2. Attach with flap up and
out using (2) #8 x 1/2”
self-tapping screws for
wood and metal doors.
(2) Through-bolt Holes
Fig. 4A
Outside of Door
Install weather conduit on
NON FIRE-RATED exterior doors only (Fig. 4B).
1. Carefully insert the weather conduit into the
ribbon cable hole on the inside of the door.
Ribbon Cable Hole
2. Place the O-ring around the weather conduit
on the outside and up against the door (Fig. 4C)
O-Ring
Fig.4C
Fig.4B
Outside of Door
1-800-810-WIRE • www.sargentlock.com • A7786E
01/29/11
B. Weather Conduit (52-2847)
Profile Series v.S2 WiFi Mortise Lock
Step #5 – Install Gasket (for Exterior Doors)
For exterior applications, use weather seal gasket between escutcheon
and outside door surface. To apply weatherseal gasket:
Gasket
1. Carefully remove the backing from the gasket. (Fig. 5A).
2. Apply gasket to escutcheon:
Keypad
Ribbon
Cable
a. Starting in one place, press the adhesive side
of the gasket firmly against the escutcheon.
b. Work around the escutcheon, pressing the
sticky side of the gasket firmly against the
escutcheon edge.
c. The gasket should be aligned so that all edges
of the escutcheon are covered.
Antenna
(iCLASS)
Only
Fig. 5A
Ground
Wire
(E1)
3. Attach escutcheon to the door.
Note: The 43 cylinder may be used with or without a gasket.
Step #6 – Install Gasket (for Exterior Doors)
1A. For fire rated doors: feed ribbon cable with connector and ground wire
from outside of door through weatherseal gasket and fire stop plate (Fig. 6A).
Note: Install ribbon cable with cable exiting down
Fig. 5B
1B. For non-fire rated doors: feed ribbon cable with connector and ground
wire from outside of door through weatherseal gasket (if used)
and weather conduit (Fig. 6B).
Note: Install ribbon cable with cable exiting down
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
2. With outside lever horizontal, locate the outside escutcheon on the door,
while directing the mounting posts through the door and lock body (Fig. 6B).
Make sure the lever spindle is properly engaged in lock.
7. On the inside of the door, insert spindle into square hole
of mortise lock.
8. Slide inside adapter and plate
assembly over spindle and loosely
secure with 2 through -bolt
screws (#8-32 x 5/8”).
Note: For 8276 and 8278,
loosely thread cylinder
through escutcheon
and into the lock body
before tightening the
lock case screws
and escutcheon
through bolts.
Reader
Cable
Antenna
(iCLASS)
Ground
Wire (E1)
Antenna
(iCLASS
only)
Keypad
Ribbon
Cable
Mortise Lock body
and AX Connectors
Fig. 6A
Fig. 6B
01/29/11
Ground
Wire (E1)
Inside of Door
10
1-800-810-WIRE • www.sargentlock.com • A7786E
Outside of Door
Profile Series v.S2 WiFi Mortise Lock
Step #7 – Inside Escutcheon Wire Connections
Images are shown without gasket. If gasket is necessary,
refer to Step #5.
Before the controller is attached to the door:
Reader
Ribbon Cable
1. Attach the reader assembly
ribbon cable into the back of the
controller assembly (side that
faces towards the door when
mounted (Fig. 7A).
2. Attach the antenna to the
circuit board in the plastic
housing under the
controller assembly.
Ground
Wire
Ground
Wire
Note: The difference between
the wiring for the iCLASS 13.56
MHz reader and the 125 kHz
Prox is that the iCLASS wiring
includes an antenna wire.
3. Attach the ground wire
to the bottom of the
controller assembly (E1).
Antenna
(iCLASS)
Outside
Escutcheon
Reader
Cable
Antenna
(iCLASS)
1. Connect the cable from the mortise lock
to the bottom of the controller assembly
(TB1, Fig. 8A).
2. Connect the AX/DPS connector to the
2-pin harness.
Antenna
Reader
Ribbon Cable
TB1
Ground
Wire
Outside
Escutcheon
Unused
Mortise
Connector
AX/DPS
Back
Inside of Door
Fig. 8A
1-800-810-WIRE • www.sargentlock.com • A7786E
11
01/29/11
Step #8 – Lock Wire Connections
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 7A
Profile Series v.S2 WiFi Mortise Lock
Step #9 – Install Inside Escutcheon
1. Gently fold the excess ribbon connector and ground
wire into the top hole, JST connectors and ground
wire into offset middle hole, and mortise and AX/DPS
wires into bottom hole, being careful not to pinch
wires (Fig. 9A).
Inside of Door
2. Insert (2) #8-32 x 1-1/4" screws through inside
escutcheon and thread into outside escutcheon.
Straighten escutcheons and tighten securely.
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Step #10 – Install Inside Lever
Fig. 9A
1. Slide lever handle onto spindle
until fully seated (Fig. 10A).
2. Tighten the set screw securely with
1/8" hex wrench.
Spindle
Inside of Door
Set Screw
Inside Lever
01/29/11
Fig. 10A
12
1-800-810-WIRE • www.sargentlock.com • A7786E
Profile Series v.S2 WiFi Mortise Lock
Step #11 – Install and Secure Cylinder
1. Slide cylinder through the spring and rosette/collar
and screw into lockbody, rotating the cylinder
clockwise (Fig. 11A).
Cylinder should be flush with escutcheon.
Outside of Door
Note: The 43 cylinder may be used when installing
this product with or without a gasket.
Note: SARGENT logo must be horizontal and
on the top of the cylinder (Fig. 11B).
2. Secure the cylinder by tightening cylinder clamp
screw located above the deadbolt using #2
Phillips screwdriver (Fig. 11C).
Type 43 Cylinder
3. Using the key, test cylinder functions:
• 8278 Function: Key retracts latch.
Key
• 8276 Function: Key retracts latch and projects
and retracts deadbolt.
Fig. 11A
Incorrect
Fig. 11B
Cylinder Clamp Screw
Outside of Door
#2 Phillips
Screwdriver
Outside of Door
Fig. 11C
Front Plate
(2) Flat Head Screws
Step #12 – Attach Front Plate
Attach front plate with (2) flat head screws.
Lock body Screws
Fig. 12A
1-800-810-WIRE • www.sargentlock.com • A7786E
13
01/29/11
Correct
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Position cylinder so that the
SARGENT logo is right-side up.
Profile Series v.S2 WiFi Mortise Lock
Step #13 – Install (or Replace) Batteries
IMPORTANT: Batteries are optional if controller is powered by external power supply.
1. To install or replace batteries, first remove the battery cover
(if necessary) using the provided security tool (Fig.13A).
2. Unscrew the bottom screw of the battery keeper
and remove the battery keeper, being careful
not to break the tabs at top that hold it in
place (Fig.13B)
3. Place (6) “AA” alkaline batteries in the
compartment, being careful to align
polarity properly.
4. Replace battery keeper being careful to engage
tabs at top to hold it in place (Fig. 13B).
5. Attach battery cover to inside escutcheon,
making sure to line up tabs with retaining
slots in battery cover.
6. Secure with the security screw
using tool. (Fig. 13A).
Fig. 13B
Tabs
Battery
Cover
Security Tool
(01-029)
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Security
Screw
Retaining
Slots
Fig. 13C
Fig. 13A
Inside of Door
14
1-800-810-WIRE • www.sargentlock.com • A7786E
Profile Series v.S2 WiFi Mortise Lock
Operational Check
For 8276 and 8278 Function mortise locks with cylinders:
1. Insert key into cylinder and rotate (There should be no friction against lock case, wire harness or any
other obstructions.
Refer to Section 7, Step 8 if harness friction exists).
2. The key will retract the latch.
Key should rotate freely.
3. If the deadbolt is thrown, the key will retract
both the deadbolt and the latch.
4. Inside lever retracts latch and
deadbolt (if provided).
5. Use a 13.56 MHz credential, 125 kHz
proximity credential, or keypad PIN code
set up with the Lock Configuration Tool to
unlock outside lever and retract latch.
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Refer to Network and Lock Configuration
Tool user manual (WFMN1D) for information on
how to configure and program v.S2 locks.
1-800-810-WIRE • www.sargentlock.com • A7786E
15
01/29/11
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-810-WIRE (9473) • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A7786E-01/11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Kirby.Munroe
Create Date                     : 2011:02:24 20:57:31-05:00
Modify Date                     : 2011:02:24 20:57:31-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2011:02:24 20:57:31-05:00
Creator Tool                    : Adobe Acrobat 9.1.1
Format                          : application/pdf
Title                           : Microsoft Word - XX-XXXX - Exhibit Cover
Creator                         : Kirby.Munroe
Document ID                     : uuid:f611e0d7-b179-4c51-a8b2-8c1cd6c2964d
Instance ID                     : uuid:500cb935-5f54-4b34-8950-2b55f4d36146
Producer                        : Adobe Acrobat 9.1.1
Page Count                      : 17
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYPROX3

Navigation menu