    5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-SCYPROX3 IC: 6982A-SCYPROX3  FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210  ACS Report Number:  10-0443.W06.11.A   Manufacturer: Assa Abloy Model: S1-PA/PK, S2-PA/PK,                                                   TCIP1-M802/M803, TCWI1-M802/M803     Manual(s)
A7786E01/11Copyright 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written  permission of Sargent Manufacturing Company is prohibited. ProfileWiFi Mortise LockInstallation Instructionsv.S2
1-800-810-WIRE • www.sargentlock.com • A7786ECopyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.01/29/11Warning: Changes or modifications to this unit not expressly approved by ASSA ABLOY Inc. could void the user’s authority to operate the equipment.Warning 11234567Table of ContentsWarning  ...................................................................................2General Description .................................................................3Hardware Specifications .........................................................3Electronic Specifications .........................................................3Installation Wiring Overview ...................................................3Lock Wiring ..............................................................................4Parts Breakdown .....................................................................5Installation Instructions ..........................................................7Operational Check  ................................................................1589To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.SARGENT Mfg. Co. v.S Series locksets utilizing a door position switch (DPS) are not rated for,or intended for use in life safety applications.!FCC: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.Industry Canada: The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications  were met.This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this  device must accept any interference received, including interference that may cause undesired operation.Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des-règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
01/29/111-800-810-WIRE • www.sargentlock.com • A7786E          3Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Profile Series v.S2 WiFi Mortise Lock Hardware SpecificationsGeneral DescriptionThe SARGENT Profile Series v.S2 mortise lock is available with either an HID® 125 kHz prox or 13.56 MHz iCLASS® technology reader. It is designed for applications requiring wireless access control. The v.S2 is a self-contained microprocessor-controlled access control product with non-volatile memory. It is able to utilize the existing wireless LAN (802.11b/g) in order to communicate with the access control system. The v.S2 lock holds a total of 2400 unique users per lock. This product is operated by six (6) “AA” alkaline batteries or a SARGENT 3267 9VDC power supply. SARGENT mortise locks are designed with quality components to provide high security, performance and durability.The Profile Series v.S2 mortise lock may be used for both indoor and exterior applications. A weather-protective gasket (provided with unit) is recommended for exterior applications.HID®  and iCLASS®  are registered trademarks of HID Global Corporation.•  Wireless (WiFi 802.11 b/g) online, battery-operated•  2400 users per lock•  10,000 Event audit trail•  Centralized lock management•  Door Status Monitoring*•  Easy installation (no need to hardwire)•  Input Power: DC 9V, 1.5A (6 AA alkaline batteries or optional hard-powered) •  Lockdown capable*•  Supports HID® 125 kHz prox or 13.56 MHz iCLASS® credentials (26 - 39 bit); supports CSN reads for other common 13.56 MHz cards, including MiFare, Des-Fire, and Felica•  Supports most current WiFi networks security standards•  For specific security information, please contact a local ASSA ABLOY Door Se-curity Solutions sales consultant or call 800-810-WIRE3Electronic Specifications42•  Latch: One-piece stainless steel, 3⁄4" projection•  Deadbolt: One-piece hardened stainless steel•  Guardbolt: Stainless steel, non-handed•  Handed: Easily field reversible without  opening case•  Case: 12-gauge, heavy duty wrought steel•  Locks furnished for 1-3/4” doors. Can be  furnished for other door sizes upon request.   Consult factory. •  UL Listed (3 hours)•  Inside lever retracts latch and deadbolt802.11b/g Wireless Network DeviceLock Management  Tool (LMT)v.S2 Lock Internal Building  Network (Intranet)Network  Interface  CardEthernet LANInstallation Wiring Overview5SARGENT Profile Series WiFi v.S2 Typical Application * Lockdown and real-time door status monitoring available only when lock is hard-powered
4          1-800-810-WIRE • www.sargentlock.com • A7786ECopyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.01/29/11Profile Series v.S2 WiFi Mortise Lock6Lock WiringDX NC (GREEN/WHITE)RX COM (WHITE)RX NC (GREEN)DX (WHITE/BLACK)LX NO (RED/YELLOW)LX COM (RED/GREENMotor B (BLACK) Motor A (RED)TB1E1 TB28765432112345678From Lock Body(+) 9VDC (RED) (-) (BLACK)AX/DPS NC (PINK) AX/DPS COM (VIOLET) UnusedUnusedUnusedEGND (GREEN)DPSPowerRing Terminal  From TrimController Board Connectors  (Inside Escutcheon)DPS
01/29/111-800-810-WIRE • www.sargentlock.com • A7786E          5Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Profile Series v.S2 WiFi Mortise Lock Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS7574899916379210911211131514156
6          1-800-810-WIRE • www.sargentlock.com • A7786ECopyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.01/29/11Profile Series v.S2 WiFi Mortise Lock1 Outside Lever Reference 8200 Catalog for available levers 12 Inside Lever Reference 8200 Catalog for available levers 13 82-0493 O/S Escutcheon only with Cylinder 182-0495 O/S Escutcheon only without Cylinder4 82-0492 Inside Escutcheon only without Thumb Turn 182-4571 Inside Escutcheon only with Thumb Turn 1552-2431 125 kHz Prox Only Bezel Assembly (PA)152-2432 Keypad and 125 kHz Prox Bezel Assembly (PK)           OR52-4422 13.56 MHz Prox Only Assembly (S2-IA)52-4423 Keypad and 13.56 MHz iCLASS Bezel Assembly (S2-IK)6 52-4425 S2 Controller Assembly (Double Pulse) 17 52-3855 Battery Cover Assembly 18 01-1212 Security Screw 19 52-2427 Profile Screw Pack - Specify Finish (Includes: Fire Stop Plate, Trim Mounting Screws, Security Allen Wrench)110 Consult Factory Lever Handle Screw (Depends on Lever Style) 111 Consult Factory Inside Adapter Assembly (Depends on Lever Style) 112 Consult Factory Outside Adapter Assembly (Depends On Lever Style) 113 S2-82276-hand-finish Lockbody with Deadbolt with Cylinder 1S2-82277-hand-finish Lockbody with Deadbolt without CylinderS2-82278-hand-finish Lockbody without Deadbolt with CylinderS2-82279-hand-finish Lockbody without Deadbolt without Cylinder14 82-0084 Faceplate with Deadbolt (shown) 182-0081 Faceplate without deadbolt 115 77-4336 Mortise Screw Pack - Specify Finish (Includes: Wood and Me-tal Lock body Screws, Faceplate Screws, and Strike Screws)116 Consult Factory #43 Mortise Cylinder 1   ITEM PART NO. DESCRIPTION QTY.Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS, continued
01/29/111-800-810-WIRE • www.sargentlock.com • A7786E          7Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Profile Series v.S2 WiFi Mortise Lock Installation Instructions8A. Verify Hand and Bevel of DoorStand on outside/locked side of door when determining the door hand.B. Door PreparationPrior to installation, all holes must be free of burrs, debris and sharp edges. Prepare door according to appropriate template (see website www.intelligentopenings.com):   Door Manufacturing Template: 4533LH  Left Hand Hinges Left Open Inward LHRB  Left Hand Reverse Bevel Hinges Left Open Outward RH Right Hand Hinges Right Open Inward RHRB  Right Hand Reverse Bevel Hinges Right Open Outward Step #1 – Door PreparationFig.  1AOutside Cylinder Hole(only with cylinder installation)Outside of Door Inside of DoorRibbon Cable Hole (Controller to Keypad)Lever Handle HoleThrough-bolt HoleRibbon Cable Hole  (Controller to Keypad)Inside of Lockbody Wire HoleLever Handle HoleThrough-bolt HolePre-drilled and/orTapped HolesMortisedPocketThumb Turn Lever HoleFig. 1B
8          1-800-810-WIRE • www.sargentlock.com • A7786ECopyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.01/29/11Profile Series v.S2 WiFi Mortise LockStep #2 – How to Change Hand of LockbodyBeveled surface of latchbolt must face strike (Fig. 2C).The deadlatch is self adjusting.To change the hand of the latchbolt:1.  Insert the blade of a slotted screwdriver (>1/4") into the spade shape slot behind latch.2.  Rotate the screwdriver 90° to push latchbolt out  until back of bolt clears lock case front.3.  Rotate latchbolt 180° until the latchbolt  drops back into the lockbody.Note: Latch cannot be unscrewed.Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A):1.  Position lock body with red surface of locking piece visible.2.  Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body.3.  Rotate the locking piece 180° until RED surface is  on opposite side.Note: Red indicates locked side (outside). Wire harness MUST exit through the  inside/non-cylinder side of the lockbody. Red Locking Piece  Indicates Locked SidePlastic  Retaining RingOutside of DoorFig.  2BSlotConnectorPush InRight Hand ShownLocking Guide SlotFig.  2AFig.  2CA. Reverse Lock HandC. Reverse Latch HandMake sure the plastic retaining ring is seated  correctly (Fig. 2B):1.  The wires and the plastic retaining ring must  be located on the non-cylinder side.2.  Orient the plastic retaining ring so that the word  Bottom is located at the bottom of the cylinder hole.3.  Route the wires from the top of the cylinder hole  into the slot on the top of the plastic retaining ring,  NOT through the retaining ring.B. Retaining Ring
01/29/111-800-810-WIRE • www.sargentlock.com • A7786E          9Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Profile Series v.S2 WiFi Mortise Lock Step #3 – Install LockbodyTo install lockbody:1.  Feed the wires first through the mortise pocket and out the inside prep, followed by the lock-body (Fig. 3A).Note: Connectors and wires must be fed through non-cylinder side. 2.  The wires from the lockbody exit the inside door prep through the mortise cutout.3.  Loosely secure the lockbody in the door with two #12 x 1-1/4" wood screws or #12-24 x 1/2" machine screws.Note: Do not completely tighten at this time.(2) #12-24 x 1/2" Long Flat Head Screws for Metal Doors(2) #12 x 1-1/4” Long Flat Head Screws for Metal DoorsFig.  3AMortise Connectors Inside of DoorStep #4 – Door OptionsA. Fire Stop Plate (P/N 52-0033)Fire-rated doors require a fire  stop plate on the outside of the  door (Fig. 4A).1.  Drill (2) 1/8" x 1-1/4" deep holes in the door if not already present.Refer to template for fire-stop prep locations.2.  Attach with flap up and  out using (2) #8 x 1/2”  self-tapping screws for  wood and metal doors. Fig.4BB. Weather Conduit (52-2847)Install weather conduit on  NON FIRE-RATED exterior doors only (Fig. 4B). 1.  Carefully insert the weather conduit into the  ribbon cable hole on the inside of the door.2.  Place the O-ring around the weather conduit  on the outside and up against the door (Fig. 4C) Outside of Door(2) 1/8” Diameter Holes RequiredFire Stop Plate(2) #8 Self-Tapping Screws for Wood  and Metal Doors(2) Through-bolt HolesFig. 4AFig.4CRibbon Cable HoleO-RingOutside of Door
10          1-800-810-WIRE • www.sargentlock.com • A7786ECopyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.01/29/11Profile Series v.S2 WiFi Mortise LockStep #5 – Install Gasket (for Exterior Doors)For exterior applications, use weather seal gasket between escutcheon  and outside door surface. To apply weatherseal gasket:1.  Carefully remove the backing from the gasket. (Fig. 5A).2.  Apply gasket to escutcheon:a.  Starting in one place, press the adhesive side  of the gasket firmly against the escutcheon.b.  Work around the escutcheon, pressing the  sticky side of the gasket firmly against the  escutcheon edge.c.  The gasket should be aligned so that all edges of the escutcheon are covered.3.  Attach escutcheon to the door.Note: The 43 cylinder may be used with or without a gasket.Step #6 – Install Gasket (for Exterior Doors) 1A. For fire rated doors:  feed ribbon cable with connector and ground wire from outside of door through weatherseal gasket and fire stop plate (Fig. 6A).Note: Install ribbon cable with cable exiting down1B. For non-fire rated doors:  feed ribbon cable with connector and ground wire from outside of door through weatherseal gasket (if used)  and weather conduit (Fig. 6B).Note: Install ribbon cable with cable exiting down2.   With outside lever horizontal, locate the outside escutcheon on the door,  while directing the mounting posts through the door and lock body (Fig. 6B).Make sure the lever spindle is properly engaged in lock.7.  On the inside of the door, insert spindle into square hole  of mortise lock.8.  Slide inside adapter and plate  assembly over spindle and loosely secure with 2 through -bolt  screws (#8-32 x 5/8”).  Note: For 8276 and 8278, loosely thread cylinder  through escutcheon  and into the lock body  before tightening the lock case screws  and escutcheon  through bolts.   Inside of DoorMortise Lock bodyand AX ConnectorsFig.  6BReader Cable Ground Wire (E1)Antenna (iCLASS)Fig.  5AKeypad RibbonCable Ground Wire  (E1)GasketAntenna(iCLASS) OnlyFig.  5BAntenna  (iCLASS only)Fig.  6AOutside of DoorKeypad RibbonCable Ground Wire (E1)
01/29/111-800-810-WIRE • www.sargentlock.com • A7786E          11Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Profile Series v.S2 WiFi Mortise Lock Step #7 – Inside Escutcheon Wire ConnectionsImages are shown without gasket. If gasket is necessary,  refer to Step #5. Before the controller is attached to the door:1.  Attach the reader assembly  ribbon cable into the back of the  controller assembly (side that  faces towards the door when  mounted (Fig. 7A). 2.  Attach the antenna to the  circuit board in the plastic  housing under the  controller assembly. Note: The difference between  the wiring for the iCLASS 13.56  MHz reader and the 125 kHz  Prox is that the iCLASS wiring  includes an antenna wire.3.  Attach the ground wire  to the bottom of the  controller assembly (E1).Step #8 – Lock Wire Connections 1.  Connect the cable from the mortise lock to the bottom of the controller assembly (TB1, Fig. 8A).2.  Connect the AX/DPS connector to the 2-pin harness. Mortise ConnectorGround WireFig.  8ABack1AX/DPS2Inside of Door12Outside  EscutcheonAntennaUnusedTB1Reader Ribbon CableGround WireFig.  7A312Antenna (iCLASS)Outside Escutcheon123Ground WireReader CableAntenna(iCLASS)Reader Ribbon Cable
12          1-800-810-WIRE • www.sargentlock.com • A7786ECopyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.01/29/11Profile Series v.S2 WiFi Mortise Lock1. Slide lever handle onto spindle       until fully seated (Fig. 10A).2. Tighten the set screw securely with      1/8" hex wrench.Step #10 – Install Inside Lever Step #9 – Install Inside Escutcheon 1.  Gently fold the excess ribbon connector and ground wire into the top hole, JST connectors and ground wire into offset middle hole, and mortise and AX/DPS wires into bottom hole, being careful not to pinch wires (Fig. 9A). 2.  Insert (2) #8-32 x 1-1/4" screws through inside  escutcheon and thread into outside escutcheon.Straighten escutcheons and tighten securely.Inside of DoorFig.  10ASpindleSet ScrewInside LeverInside of DoorFig.  9A
01/29/111-800-810-WIRE • www.sargentlock.com • A7786E          13Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Profile Series v.S2 WiFi Mortise Lock Step #12 – Attach Front PlateAttach front plate with (2) flat head screws.Step #11 – Install and Secure Cylinder1.  Slide cylinder through the spring and rosette/collar  and screw into lockbody, rotating the cylinder  clockwise (Fig. 11A).Cylinder should be flush with escutcheon.Note: The 43 cylinder may be used when installing  this product with or without a gasket.Note: SARGENT logo must be horizontal and  on the top of the cylinder (Fig. 11B). 2.  Secure the cylinder by tightening cylinder clamp  screw located above the deadbolt using #2  Phillips screwdriver (Fig. 11C).3.  Using the key, test cylinder functions: •  8278 Function: Key retracts latch.•  8276 Function: Key retracts latch and projects  and retracts deadbolt.Fig.  11BPosition cylinder so that the SARGENT logo is right-side up.Correct            IncorrectFig.  11AOutside of DoorKeyType 43 CylinderFig.  12AOutside of DoorFront Plate(2) Flat Head ScrewsLock body ScrewsCylinder Clamp Screw#2 Phillips ScrewdriverOutside of DoorFig.  11C
14          1-800-810-WIRE • www.sargentlock.com • A7786ECopyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.01/29/11Profile Series v.S2 WiFi Mortise LockIMPORTANT:  Batteries are optional if controller is powered by external power supply.1.  To install or replace batteries, first remove the battery cover  (if necessary) using the provided security tool (Fig.13A). 2.  Unscrew the bottom screw of the battery keeper  and remove the battery keeper, being careful  not to break the tabs at top that hold it in  place  (Fig.13B) 3.  Place (6) “AA” alkaline batteries in the  compartment, being careful to align  polarity properly.4.  Replace battery keeper being careful to engage  tabs at top to hold it in place (Fig. 13B).5.  Attach battery cover to inside escutcheon,  making sure to line up tabs with retaining  slots in battery cover. 6.  Secure with the security screw  using tool. (Fig. 13A).Step #13 – Install (or Replace) BatteriesFig. 13BFig. 13CTabsRetaining SlotsInside of DoorFig. 13ASecurity Tool (01-029)Battery CoverSecurity Screw
01/29/111-800-810-WIRE • www.sargentlock.com • A7786E          15Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Profile Series v.S2 WiFi Mortise Lock For 8276 and 8278 Function mortise locks with cylinders:1.  Insert key into cylinder and rotate (There should be no friction against lock case, wire harness or any other obstructions. Refer to Section 7, Step 8 if harness friction exists).2.  The key will retract the latch. Key should rotate freely.3.  If the deadbolt is thrown, the key will retract  both the deadbolt and the latch.4.  Inside lever retracts latch and  deadbolt (if provided).5.  Use a 13.56 MHz credential, 125 kHz  proximity credential, or keypad PIN code  set up with the Lock Configuration Tool to unlock outside lever and retract latch. Refer to Network and Lock Configuration Tool user manual (WFMN1D) for information on how to configure and program v.S2 locks.Operational Check 9.
SARGENT Manufacturing100 Sargent DriveNew Haven, CT 06511 USA800-810-WIRE (9473) • www.sargentlock.comFounded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The company’s customer base includes commercial construction, institutional, and industrial markets.Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.ASSA ABLOY is the global leader in door opening solutions, dedicated tosatisfying end-user needs for security, safety and convenience. A7786E-01/11