ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX Exhibit Cover

ASSA ABLOY Inc. Microprocessor Controlled Networked Locks XX XXXX Exhibit Cover

Contents

Manual 2 of 3

Download: ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX   Exhibit Cover
Mirror Download [FCC.gov]ASSALOY SCYPROX3 Microprocessor Controlled Networked Locks User Manual XX XXXX   Exhibit Cover
Document ID1434415
Application ID/QxprcOsA3EX13m/9ZWA7w==
Document DescriptionManual 2 of 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize386.33kB (4829158 bits)
Date Submitted2011-03-21 00:00:00
Date Available2011-03-21 00:00:00
Creation Date2011-02-24 20:56:43
Producing SoftwareAdobe Acrobat 9.1.1
Document Lastmod2011-02-24 20:56:43
Document TitleMicrosoft Word - XX-XXXX - Exhibit Cover
Document CreatorAdobe Acrobat 9.1.1
Document Author: Kirby.Munroe

Certification Exhibit
FCC ID: U4A-SCYPROX3
IC: 6982A-SCYPROX3
FCC Rule Part: 15.209
IC Radio Standards Specification: RSS-210
ACS Report Number: 10-0443.W06.11.A
Manufacturer: Assa Abloy
Model: S1-PA/PK, S2-PA/PK,
TCIP1-M802/M803, TCWI1-M802/M803
Manual(s)
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
v.S1
Profile
PoE Mortise Lock
Installation Instructions
A7764B
01/11
Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Table of Contents
Warning . ..................................................................................2
General Description..................................................................3
Hardware Specifications..........................................................3
Electronic Specifications..........................................................3
Installation Wiring Overview....................................................3
Installation Wiring....................................................................4
Parts Breakdown......................................................................8
Lock Installation.....................................................................10
Operational Check .................................................................17
Warning
Changes or modifications to this unit not expressly approved by ASSA ABLOY Inc.
could void the user’s authority to operate the equipment.
FCC:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Industry Canada:
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were
met.
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe A répond à toutes les exigences de l’interférence canadienne causant des
règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui
peut causer l’opération peu désirée.
Warning SARGENT Mfg. Co. v.S Series locksets utilizing a door position switch (DPS) are not rated for,
or intended for use in life safety applications.
1-800-810-WIRE • www.sargentlock.com • A7764B
Profile Series v.S1 PoE Mortise Lock
General Description
The SARGENT Profile Series v.S1 Mortise Lock is available with either an HID® 125 kHz prox or 13.56 MHz
iCLASS® technology reader. It utilizes existing infrastructure and IEEE 802.3af PoE (Power over Ethernet)
technology as a proven alternative to traditional access control installations.The v.S1 is a self-contained
microprocessor-controlled access control product with non-volatile memory. It uses the existing network
cable to communicate with access control systems. The v.S1 lock holds a total of 2400 unique users per lock.
Using PoE technology coupled with approved third party software, this v.S1 online lock offers a complete,
integrated access control system.
The Profile Series v.S1 Mortise lock may be used for both indoor and exterior applications.
A weather-protective gasket is recommended for exterior applications.
HID and iCLASS are registered trademarks of HID Global Corporation.
•
•
Complete lockset with on-board memory
Available with or without keypad
ADA compliant
Latch: One-piece stainless steel, 3⁄4"projection
Deadbolt: One-piece hardened stainless steel
Guardbolt: Stainless steel, non-handed
Case - 12 gauge, heavy duty, wrought steel
Inside lever retracts latch and deadbolt
UL Listed (3 hr.)
Handing (RH/LH/RHR/LHR) can be specified
but is easily field-reversible without
disassembling the lock body
Locks furnished for 1-3/4” doors. Can be furnished for other door sizes upon request. Consult factory.
Wire from EAC Panel to door must be shielded
with drain terminated at EAC Panel controller
Electronic Specifications
•
•
2400 users per lock; 10,000 event audit trail
Multiple time zone and holiday
access scheduling
Centralized lock management
Real time door status monitoring
First-In unlock configuration, either by time
or by user (selectable)
Lock down capable
Input Power: PoE Class 2 Device, as defined
by IEEE 802.3af
Supports HID® 125 kHz prox or 13.56 MHz
iCLASS® credentials (26 - 39 bit); supports
CSN reads for other common 13.56 MHz
cards, including MiFare, DesFire, and Felica
•
•
•
•
•
•
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Hardware Specifications
•
•
•
•
•
•
•
•
•
•
Installation Wiring Overview
Supplied by Others
Network
Cable
Surface Mount RJ45
Network Switch (802.3af)
A. PoE Frame harness assembly
B. PoE data hinge from McKinney
(patent pending)
C. PoE Door harness* from McKinney
D. Profile Series S1 PoE Lock
* Door width determines length
1-800-810-WIRE • www.sargentlock.com • A7764B
01/29/11
Profile Series v.S1 PoE Mortise Lock
6 Installation Wiring
PoE frame harness assembly (From McKinney)
D DPS: Door Position Switch (cylindrical and exits only)
PoE data hinge (Patent Pending) (From McKinney)
PoE door harness* (From McKinney)
Profile Series v.S1 Online P1 PoE lock
* Order of installation may vary.
Refer to appropriate sections for instructions.
Supplied by CI
Supplied by End User
Certified Integrator (CI) supplies and terminates
the B-Splice connector and the
Male RJ45 connector from harness to
Patch Cable:
end user provided facility cable
Patch Panel to
PoE Switch
B-Splice
Crimp Connector
PoE Switch
Drain Wire
RJ45-M
RJ45-F Jack
01/29/11
24AWG
Stranded
Wire for
Earth
Ground
inside
15' Frame
Harness
FrameSide
Harness
Assembly
(15' length)
Cable
drain wire
concealed
in shrink
tubing
Cable: CAT 5e or higher
24 AWG shielded with drain wire
Cable: CAT 5e or higher
24 AWG shielded, 100ohm
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Ceiling
Patch Panel
Drain Wire Terminated on Rack
Approved Software
Cable: CAT 5e,
26 AWG stranded,
shielded, 100ohm
Molex-M
PoE Switch
Terminated to
Earth Ground
4-Pin
Notes:
•
Connectors go on
only one way. They
cannot placed in an
incorrect position.
•
Do not force and do
not offset connectors.
•
Be sure they are
completely seated
(flush).
4-Pin
Molex-F Molex-M
Molex-F
PoE
Lock
Ground
Ring Terminal
Secured to Lock
Mounting Plate
Wiring to TIA-568-B Standard
1-800-810-WIRE • www.sargentlock.com • A7764B
Profile Series v.S1 PoE Mortise Lock
Frame Harness Installation
Cut end / ceiling-side PoE harness:
Supplied by CI
Suggested installation of components and wire harness supplied by McKinney:
B-Splice
Crimp Connector
TIA-568-B Standard Wiring
3 4 5 6 7
Pair Number
White/Blue
White/Orange
RJ45-M
Ceiling
White/Brown
White/Blue
Blue
White/Orange
Orange
White/Green
Green
White/Brown
Brown
Do not confuse pair numbers with pin numbers. A pair number is used for
reference only (e.g.: 10Base-T Ethernet uses pairs 2 & 3). The pin numbers
indicate actual physical locations on the plug and jack.
Hinge side of PoE harness:
1. Feed cut end of harness into hole on hinge-side through single access hole.
2. Push one of the connectors back through hole and feed into separate
access hole.
Molex-M
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Cable
drain wire
concealed
in shrink
tubing
White/Green
PIN
Each of the hinge-side harness connectors should end up threaded through
a different access hole and matched to the same size pin connector from
the door harness:
•
4-pin male Molex connector.
•
6-pin male Molex connector with ground wire.
PoE Data Hinge
Hinge-side harness connectors:
4-pin M 4-pin F
•
4-pin male molex connector
•
6-pin male molex connector with ground wire
Lock-side harness connectors:
6-pin M
Frame
6-pin F
Drain Wire
•
Ring terminal
•
(2) 4-pin connectors
•
4-pin Molex connector
•
4-pin connector
PoE Hinge (Patent Pending)
1-800-810-WIRE • www.sargentlock.com • A7764B
01/29/11
Frame-Side
Harness
Assembly
(15' length)
Cable: CAT 5e or higher
24 AWG shielded, 100ohm
24AWG
Stranded
Wire for
Earth
Ground
inside
15' Frame
Harness
Wire
Profile Series v.S1 PoE Mortise Lock
Door Harness Installation
Ground
Ring Terminal
Order of installation may vary.
Refer to appropriate sections for instructions.
1. Prop door open.
2. Tape the two lock-side 4-pin connectors to the ring terminal.
3. Using the ring terminal, carefully fish the assembly through the
door channel to the lock.
4. Remove tape from ring terminal and door harness connectors.
Hinge-side harness connectors:
• 4-pin male Molex connector
• 6-pin male Molex connector with ground wire
Lock-side harness connectors:
• Ring terminal
• (2) 4-pin connectors:
• 4-pin Molex connector
• 4-pin connector
JST 4-Pin
From Hinge
Connectors
From Lock body
Inside of Door
PoE Lock
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
4-pin F
Drain Wire
6-pin M
JST
4-Pin
Cable: CAT 5e,
26 AWG stranded,
shielded, 100ohm
4-Pin
Molex
Ground
Ring Terminal Secured
to Lock Mounting Plate
1-800-810-WIRE • www.sargentlock.com • A7764B
Profile Series v.S1 PoE Mortise Lock
PoE Lock Wiring
Ground Ring Terminal
(From Hinge to Top Left Escutcheon Screw)
JP4
JP4
TP8
TP7
R22
R23
R21
TP7
TP8
C31
MTG2
R25
J6
23C
MTG2
2ND
23C
4U
8R
51C
4R
51C
4R
U1
5D
4U
5R
11R 5R
5D
2D
3C
3C
MTG3
U2
6R11R
L1
J7
U3
C4
7R
TP1
TP2
TP6
J3
31D
2ND
1ND
73C
1ND
J5
T1
41C
73C
1C
01C
8 1C
1C
8R
8 1C
01C
C20
6R
D4
D7
7R
11C
D3
C2
C12
C16
R15
J4
5C
R14
C19
TP4 DN3
TP3
31C
R12
R9
D6
41C
Q1
R2
R6
11C
MTG3
C5
C11
C14
R4
5C
C3
R7
R11
C12
D4
J3
C4
C4
J5
J5
T1
J7
TP6 U3
TP2
U2 J7
U3
C13
C19
TP1
L1
TP1
TP6
C20
TP2
D2
C12
D4
T1
C20
D7
J3
C15
C19
1U
R12
R14
D3
C2
R2
R12
R14
D7
R15
C16
D5
MTG4
1U
R3
D3
Q1
C2
TP4 DN3
TP3
R5
Q1
R2
MTG4
R15
C16
C6
R1
U4
C6
R3
C6
71C
61R 31R 01R
71C
61R 31R 01R
D6
R9
D6
J7, J4
JST Connectors
(From Hinge)
C34
TP4 DN3
TP3
R3
D1
R8
D1
C35
C36
R1
R1R9
T2
D1
C18
C10
C17
R10 R13 R16
T2
C1
C37
T2
C35
MTG2
C34
MTG4
C35
C36
C34
C36
J6
DN1
J8 J2
MTG1
TP9
J6
DN2
MTG1
R24
J8 J2
C32
MTG1
C7 C8
TP5
J8 J2
C7 C8
D11
C33
TP5
R24
R25
C31
C9
D9
D9
R22
C7 C8
D9
D11
C33
TP9
JP3
TP5
D10
R22
C31
D11
TP7
TP8 R21C33 D10R24
TP9R23 R25
C9
C21
C9
R21
R23
JP4
JP3
JP3
D10
C21
C21
MTG3
J4
U2
L1
J4
D1
D9
R2
D1
C3
C2
R2
MTG4
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
U2
TP
C4
C1
2ND
1ND
73C
2ND
1ND
23C
1C
01C
73C
71C
31R 01R
61R
8 1C
1C
71C
31R 01R
081
8 1C
4U
61R
MTG3
J4
8R
J7
U3
5R
TP
TP
L1
C1
D4
R1
6R
L1
D4
(+) 9VDC (RED)
(-) (BLACK)
AX/DPS NC (PINK)
AX/DPS COM (VIOLET)
Unused
Unused
Unused
EGND (GREEN)
DX NC (GREEN/WHITE)
RX COM (WHITE)
RX NC (GREEN)
DX (WHITE/BLACK)
LX NO (RED/YELLOW)
LX COM (RED/GREEN
Motor B (BLACK)
Motor A (RED)
DPS
DPS
From
Lock Body
Ring Terminal
From Trim
Power
1-800-810-WIRE • www.sargentlock.com • A7764B
01/29/11
R1
J3
D3
U1
R3
D7
5D
4U
Q1
C6
D6
C2
T2
2D
J5
T1
5D
J8
J2
3C
DN
R9 C1
R1
5R
11R
51C
TP
TP
4R
D1
7R
R1
C8
2D
31C
MTG1
TP
C7
4R
R 115R1C
C9
11C
31C
41C
J6
23C
MTG2
C3
C3
JP
3C
TP
C2
7R
25
5C
C5
41C
C11
C14
R6
11C
TB2
TB1
C13
5C
E1
J4
R7
U2
C4
R4
TP
TP L1
C3
C1
MTG3
MTG3
R11
C15
D4
C1
J7
6 U
TP
J7
TP 2
U3
J3
J4
C4
D2
C1
1U
C1
P6
0T
C2 TP2
J3
D5
1U
R1
R1
R2
R1
R1
D3
C2
Controller Board Connectors
(Inside Escutcheon)
T1
R5
Q1C2
R2
C2
U4
D3
MTG4
MTG4
Q1
D7
R8
T2
C6
3D7
TP
D6
R1
R9 C1
D6
C18
T2
J5
T1J5
C1
D1
J2
R9
C10
MTG1
3 3
TP DN
R1 4
TC1P6
C17
R10 R13 R16
D1
R1
DN
C37
C8
C7
TP J8 J2
C8
C7
R3
TP
R1
DN1
TP
DN2
C3
C3
J6
MTG1
RC36
C32
J6
JP
J8
MTG2
C3
C3
C3
C3
MTG2
C2
C9
C9
R2
C3
TP
C3
TB1 E1 TB2
C3
C3
C3
R2
D9
D1
1 0 R2
R2
C2
R2
D1
TP8 R231
TJPP4R22
R2
D1
TP8 R213 C3 D925
TP R29 2 R1
D1
TPR21 R24
JP
JP
P4
TP
TP8
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Profile Series v.S1 PoE Mortise Lock
Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS
10
16
12
11
13
1-800-810-WIRE • www.sargentlock.com • A7764B
15
14
15
Profile Series v.S1 PoE Mortise Lock
Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS, continued
ITEM
PART NO.
DESCRIPTION
QTY.
Outside Lever
Reference 8200 Catalog for available levers
Inside Lever
Reference 8200 Catalog for available levers
82-0493
O/S Escutcheon only with Cylinder
82-0495
O/S Escutcheon only without Cylinder
82-0492
Inside Escutcheon only without Thumb Turn
82-4571
Inside Escutcheon only with Thumb Turn
52-2431
125 kHz Prox Only Bezel Assembly (PA)
52-2432
Keypad and 125kHz Prox Bezel Assembly (PK)
OR
52-4420
13.56 MHz iCLASS Only Bezel Assembly (S1-IA)
13.56 MHz reader assembly ships configured for PoE/Hardpower use.
52-4421
Keypad and 13.56 MHz Bezel Assembly (S1-IK)
52-4424
S1 Controller Assembly (Double Pulse)
52-3855
Battery Cover Assembly
01-1212
Security Screw
52-2427
Profile Screw Pack - Specify Finish (Includes: Fire Stop Plate,
Trim Mounting Screws, Security Allen Wrench)
10
Consult Factory
Lever Handle Screw (Depends on Lever Style)
11
Consult Factory
Inside Adapter Assembly (Depends on Lever Style)
12
Consult Factory
Outside Adapter Assembly (Depends On Lever Style)
13
14
15
16
S1-82276-hand-finish
Lockbody with Dead Bolt with Cylinder
S1-82277-hand-finish
Lockbody with Dead Bolt without Cylinder
S1-82278-hand-finish
Lockbody without Dead Bolt with Cylinder
S1-82279-hand-finish
Lockbody without Dead Bolt without Cylinder
82-0084
Faceplate with Dead Bolt (shown)
82-0081
Faceplate without Dead Bolt
77-4336
Mortise Screw Pack - Specify Finish (Includes: Wood and Metal Lock body Screws, Faceplate Screws, and Strike Screws)
#43 Mortise Cylinder
Consult Factory
1-800-810-WIRE • www.sargentlock.com • A7764B
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
13.56 mHz reader assembly ships configured for PoE/Hardpower use.
Profile Series v.S1 PoE Mortise Lock
Lock Installation
Step #1 – Door Preparation
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
LH
LHRB
RH
RHRB
Left Hand
Hinges Left
Open Inward
Left Hand
Reverse Bevel
Hinges Left
Open Outward
Right Hand
Hinges Right
Open Inward
Right Hand
Reverse Bevel
Hinges Right
Open Outward
Fig. 1A
B. Door Preparation
Prior to installation, all holes must be free of burrs, debris and sharp edges.
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Prepare door according to appropriate template (see website www.intelligentopenings.com):
• Manufacturer Door Template: 4533
Outside of Door
Inside of Door
Through-bolt Hole
Through-bolt Hole
*Raceway
Ribbon Cable Hole
(Controller to Keypad)
Ribbon Cable Hole
(Controller to Keypad)
Inside of Lockbody Wire Hole
(only with cylinder installation)
Outside of Cylinder Hole
(only with cylinder installation)
Thumb Turn Lever Hole
Lever Handle Hole
Lever Handle Hole
Mortised
Pocket
*Note: Raceway placement in
document is approximate.
10
Pre-drilled and/or
Tapped Holes
Fig. 1B
1-800-810-WIRE • www.sargentlock.com • A7764B
Profile Series v.S1 PoE Mortise Lock
Step #2 – How to Change Hand of Lockbody
A. Reverse Lock Hand
Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A):
1. Position lock body with red surface of locking piece visible.
2. Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body.
3. Rotate the locking piece 180° until RED surface is on opposite side.
Note: Red indicates locked side (outside).
Wire harness MUST exit through the
inside/non-cylinder side of the lockbody.
B. Retaining Ring
Slot
Make sure the plastic retaining ring is seated
correctly (Fig. 2B):
1. The wires and the plastic retaining ring
must be located on the non-cylinder side.
2. Orient the plastic retaining ring so that the word
Bottom is located at the bottom of the cylinder hole.
Plastic
Retaining
Ring
3. Route the wires from the top of the cylinder hole
into the slot on the top of the plastic retaining ring,
NOT through the retaining ring.
Fig. 2B
Outside of Door
Locking
Guide
Slot
Push In
Fig. 2A
C. Reverse Latch Hand
Beveled surface of latchbolt must face strike.
The deadlatch is self adjusting.
To change the hand of the latchbolt:
1. Insert the blade of a slotted screwdriver (>1/4”)
into the spade shape slot behind latch.
2. Rotate the screwdriver 90° to push latchbolt
out until back of bolt clears lock case front.
3. Rotate latchbolt 180° until the latchbolt
drops back into the lockbody.
Note: Latch cannot be unscrewed.
Fig. 2C
1-800-810-WIRE • www.sargentlock.com • A7764B
11
01/29/11
Right Hand Shown
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Red Locking Piece
Indicates Locked Side
Profile Series v.S1 PoE Mortise Lock
Ground
Wire
Step #3 – Install Lockbody
1. Feed the wires first through the mortise pocket
and out the inside prep, followed by the lockbody (Fig. 3A).
(2) 4-Pin
Connectors
From Hinge
Note: Connectors and wires must be fed
through non-cylinder side.
2. The wires from the lockbody exit the inside door
prep through the mortise cutout.
3. Loosely secure the lockbody in the door with
two #12 x 1-1/4” wood screws or #12-24 x 1/2”
machine screws.
Note: Do not completely tighten at this time.
Mortise
Connectors
(2) #12-24 x 1/2” Long
Flat Head Screws
for Metal Doors
Inside of Door
Fig. 3A
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
(2) #12 x 1-1/4” Long
Flat Head Screws
for Metal Doors
Step #4 – Door Options
(2) 1/8” Diameter
Holes Required
A. Fire Stop Plate (P/N 52-0033)
Fire-rated doors require a fire stop plate on
the outside of the door (Fig. 4A).
Fire Stop Plate
1. Drill (2) 1/8" x 1-1/4" deep holes in the
door if not already present.
(2) #8 Self-Tapping
Screws for Wood
and Metal Doors
Refer to template for fire-stop
prep locations.
2. Attach with flap up and
out using (2) #8 x 1/2”
self-tapping screws for
wood and metal doors.
(2) Through-bolt Holes
Fig. 4A
Outside of Door
B. Weather Conduit (52-2847)
Install weather conduit on
NON FIRE-RATED exterior doors only (Fig. 4B).
1. Carefully insert the weather conduit into the
ribbon cable hole on the inside of the door.
Ribbon Cable Hole
O-Ring
2. Place the O-ring around the weather conduit
on the outside and up against the door (Fig. 4C)
Fig.4C
Fig.4B
12
1-800-810-WIRE • www.sargentlock.com • A7764B
Outside of Door
Profile Series v.S1 PoE Mortise Lock
Step #5 – Install Gasket (for Exterior Doors)
Gasket 82-0500
1. Carefully remove the backing from the gasket.
2. Apply gasket to escutcheon:
Gasket
• Starting in one place, press the adhesive side
of the gasket firmly against the escutcheon.
• Work around the escutcheon, pressing the sticky side
of the gasket firmly against the escutcheon edge.
Keypad
Ribbon
Cable
• The gasket should be aligned so that all edges
of the escutcheon are covered.
Fig. 5A
3. Attach escutcheon to the door after the wires
are connected.
Antenna
(iCLASS)
Only
Note: The 43 cylinder may be used with or without a gasket.
Ground
Wire
(E1)
Step #6 – Install Outside Escutcheon and Lever Assembly
1A. For fire rated doors, feed ribbon cable with connector and ground wire from
outside of door through weatherseal gasket and fire stop plate (Fig. 6A).
Note: Install ribbon cable with cable exiting down
1B. For non-fire rated doors, feed ribbon cable with connector and ground
wire from outside of door through weatherseal gasket (if used)
and weather conduit (Fig. 6A).
Fig. 5B
Note: Install ribbon cable with cable exiting down
With outside lever horizontal, locate the outside escutcheon on the door,
while directing the mounting posts through the door and lock body (Fig. 6B).
3.
On the inside of the door, insert spindle into square hole
of mortise lock.
4.
Slide inside adapter and plate
assembly over spindle and loosely
secure with 2 through bolt
Ground
screws (#8-32 x 5/8”).
Note: For 8276 and 8278,
loosely thread cylinder
through escutcheon
and into the lock body
before tightening the
lock case screws
and escutcheon
through bolts.
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Make sure the lever spindle is properly engaged in lock.
Ring Terminal
Ground
Wire (E1)
JST 4-Pin
From Hinge
Reader
Cable
Antenna
(iCLASS)
Ground
Wire (E1)
Antenna
(iCLASS
only)
Keypad
Ribbon
Cable
Mortise Lock body
and AX Connectors
Inside of Door
Fig. 6A
Fig. 6B
Outside of Door
1-800-810-WIRE • www.sargentlock.com • A7764B
13
01/29/11
2.
Profile Series v.S1 PoE Mortise Lock
Step #7 – Escutcheon Wire Connections
Images are shown without gasket. If gasket is necessary,
refer to Step #5.
Ground Ring
Terminal
Before the controller is attached to the door:
4-Pin Connectors
From Hinge
1. Attach the reader assembly
ribbon cable into the back of the
controller assembly (side that
faces towards the door when
mounted (Fig. 7C Detail).
2. Attach the antenna to the
circuit board in the plastic
housing under the
controller assembly.
Antenna
(iCLASS only)
Ground
Wire
Ground
Wire
Note: The difference between
the wiring for the iCLASS 13.56
MHz reader and the 125 kHz
Prox is that the iCLASS wiring
includes an antenna wire.
3. Attach the ground wire
to the bottom of the
controller assembly
(E1, Fig. 7A).
Reader
Cable
Outside
Escutcheon
Reader
Cable
Antenna
(iCLASS)
01/29/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 7A
Step #8 – Additional Wiring Connections
Lock, DPS and raceway wire connections:
1. Connect the cable from the mortise lock
to the bottom of the controller
assembly (TB1, Fig. 8A).
2. Connect the AX/DPS connector
to the 2-pin harness.
3. Push the two connectors from the
raceway over the controller assembly,
through the gap between the
plastic controller assembly
and the escutcheon,
Outside
to the front of the
Escutcheon
circuit board.
Ground
Ring
Terminal
4-Pin
Connectors From Hinge
Antenna
(iCLASS only)
Reader
Cable
TB1
Ground
Wire
Unused
Mortise
Connector
AX/DPS
Back
Inside of Door
Fig. 8A
14
1-800-810-WIRE • www.sargentlock.com • A7764B
Profile Series v.S1 PoE Mortise Lock
Step #9 – Ciruit Board Wiring
Before installing escutcheon, route raceway cables and ground attach to
front of circuit board.
Turn the controller assembly over:
Ground
Ring
Terminal
1. Route the raceway connectors over the top of the controller assembly
and plug into the front of the circuit board (side that faces out when
mounted (J7, J4; Fig. 9A).
2. Route the 2 ground ring terminals, one from the lock and the other
from the hinge wiring, over the top of the controller assembly and connect both to the top escutcheon screw.
Note: Connectors go on only one way.
Do not offset connectors and make sure they are completely seated.
Inside of Door
Step #10 – Install Inside Escutcheon
1. Gently fold the excess ribbon connector and ground wire into the
top hole, JST connectors and ground wire into offset middle hole,
and mortise and AX/DPS wires into bottom hole, being careful not
to pinch wires (Fig. 10A).
2. Insert (2) #8-32 x 1-1/4" screws through inside escutcheon and
thread into outside escutcheon (Fig. 10B)
Straighten escutcheons and tighten securely.
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 9A
Inside of Door
Fig. 10B
1-800-810-WIRE • www.sargentlock.com • A7764B
15
01/29/11
Fig. 10A
Profile Series v.S1 PoE Mortise Lock
Step #11 – Install Inside Lever
1. Slide lever handle onto spindle until fully seated (Fig. 11A).
2. Tighten the set screw securely with 1/8” hex wrench.
Spindle
Step #12 – Install and Secure Cylinder
Set Screw
1. Slide cylinder through the spring and rosette/collar
and screw into lockbody, rotating the cylinder
clockwise (Fig. 12A).
Cylinder should be flush with rosette/collar.
Fig. 11A
Note: SARGENT logo must be horizontal and on
the top of the cylinder (Fig. 12B).
Inside of Door
2. Secure the cylinder by tightening cylinder clamp
screw located above the deadbolt using #2 Phillips
screwdriver (Fig. 12C).
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
01/29/11
Inside Lever
3. Using the key, test cylinder functions:
• 8278 Function: Key retracts latch-.
• 8276 Function: Key retracts latch and projects
and retracts deadbolt-.
Position cylinder so that the
SARGENT logo is right-side up.
Correct
Incorrect
Type 43 Cylinder
Fig. 12B
Cylinder Clamp Screw
Key
Fig. 12A
#2 Phillips
Screwdriver
Outside of Door
Fig. 12C
16
1-800-810-WIRE • www.sargentlock.com • A7764B
Profile Series v.S1 PoE Mortise Lock
Step #13 – Attach Front Plate
Attach front plate with (2) flat head screws.
Outside of Door
Front Plate
(2) Flat Head Screws
Lock body Screws
Fig. 13A
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Operational Check
1A. For 8276- and 8278- function mortise locks with cylinders:
• Insert key into cylinder and rotate.
There should be no friction against lock case,
wire harness or any other obstructions.
•
Refer to Section 6, Step 8 Wiring
if harness friction exists).
Check that the key retracts the latch:
The key should rotate freely.
1B. For 8276- and 8277- function:
• Throw the deadbolt:
Check that the key retracts both the
deadbolt and the latch.
• Try the inside lever:
Ensure it retracts latch and deadbolt (if provided).
2. Use a prox 125 kHz or 13.56 MHz iCLASS credential,
or keypad PIN code set up with the Network and Lock
Configuration Tool to unlock outside lever and retract latch.
Refer to Network Lock and Configuration Tool user manual
(WFMN1D) for information on how to configure and program
v.S1 locks.
1-800-810-WIRE • www.sargentlock.com • A7764B
17
01/29/11
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-810-WIRE (9473) • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A7764B-01/11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Kirby.Munroe
Create Date                     : 2011:02:24 20:56:43-05:00
Modify Date                     : 2011:02:24 20:56:43-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2011:02:24 20:56:43-05:00
Creator Tool                    : Adobe Acrobat 9.1.1
Format                          : application/pdf
Title                           : Microsoft Word - XX-XXXX - Exhibit Cover
Creator                         : Kirby.Munroe
Document ID                     : uuid:8361f42c-ce5f-4381-8b65-91272e45ecfe
Instance ID                     : uuid:a03e6e83-3fd0-4e2a-b042-143bfc3d825a
Producer                        : Adobe Acrobat 9.1.1
Page Count                      : 19
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYPROX3

Navigation menu