Adura Technologies LCR10P2 Lighting control for commercial and industrial buildings User Manual Light Controller Manual Final

Adura Technologies, Inc. Lighting control for commercial and industrial buildings Light Controller Manual Final

Users Manual

Specications:Ordering Information:LC - 1RLC Instructions 06.09Single relayLC - 2R Two relayOptional external antenna     XACatalog Number DescriptionADURA TECHNOLOGIES™San Francisco, CA 94105Tel: 415.227.0868 • Toll Free 1-888-828-8281ADURA TECHNOLOGIES™San Francisco, CA 94105Tel: 415.227.0868 • Toll Free 1-888-828-8281w w w . a d u r a t e c h . c o mlight controllerInput Voltage:Input Frequency:Relays: Max Switched Current:Radio Frequency:RF Transmission Output Power (Average):100 – 277 VAC60 HzNormally open, SPST, zero crossing control5A Ballast/5A Tungsten (LC-2R = 5A x 2 relays)2.4 GHz+12 dBmMounting: Magnets or screws inside of a UL-rated xture or enclosure rated for the applicationDimensions:Operating Environment: 40 to 140 deg FMemory: Conguration programming stored in non-volatile memoryCurrent measurement:Voltage measurement:  2% accuracy full scale 2% accuracy full scaleWires: 24” 600 VAC Rated, 18 AWG solid conductors7” 5/8 L x 1“ 3/16 W x 1” HCAUTION• Disconnect all incoming power before installation or service.• All installation and maintenance work must be performed by qualied personnel.• The Light Controllers must be installed in accordance with state, local and national    electrical codes and requirements.• The Light Controller must be installed within a UL-rated xture or enclosure rated for    this application. INSTALLATIONINSTRUCTION MANUALThe Light Controller is to be used to control lighting in commercial and industrial buildings. It provides control of lights (on/o or dimming) by means of commands transmitted and received via radio frequency. The Light Controller is intended to be used in a network of devices which communicate wirelessly, such as wall switches, occupancy sensors, gateways and software management tools.The Light Controller is to be mounted inside the enclosure of a light xture or in a separate UL-rated enclosure. In the case of uorescent lights, the Light Controller is to be installed inside the ballast cavity of a standard uorescent luminaire.The Light Controller is intended to be used to control uorescent ballasts, incandescent lights, LED drivers and HID ballasts.There are 3 models of the Light Controller:• LC-1R has one relay and is intended to control one light xture or group of light xtures.• LC-2R has two relays and is intended to control two levels of light within one xture or   two xtures or two groups of light xtures.• LC-1RD has one relay and a low voltage dimming output (Class 1 rated) intended to   control standard 0-10 VDC dimming ballasts. Each LC-1RD can provide dimming control to   a maximum of 5 standard  0-10 VDC dimming ballasts.LC - 1RD Single relay with 0-10 VDC dimmingTM TMInstallation Materials (Not Supplied)Wiring connectors. All existing wiring connectors must be replaced with new UL listed wiring connectors, either wire nuts or captive-type connectors. All wiring connectors must be correctly sized for the application, the number and the size of the electrical conductors.Sheet metal screws. As an option, the Light Controller can be secured with 2 #8 sheet metal screws. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful Interference when the equipment is operated in a commercial environment.  The equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communica-tions.  Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.Class A Digital DevicesWARRANTY INFORMATIONAdura Technologies™ warranties its products to be free of defects for a period of ve years.  Adura Technologies will, at its option, repair or replace any product that is defective in materials or manufacture that is returned to ADURA within the warranty period.  This warranty is void if this product has been installed improperly or in an improper environment, overloaded, misused, or altered in any manner, or not installed in accordance with any labels or instructions.  Adura Technologies is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of property, revenue or prot.   This warranty does not cover the cost of installation, removal or reinstallation. To comply with RF exposure compliance requirements, for mobile congurations, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter.
1 3/16”7 1/4”Installation Instructions:1.  Turn o all power to the light xtures by      switching o the circuit breaker. 2.  Open the xture cover and remove the cover      for the ballast cavity. The ballast and its wiring        should now be visible. (See Figure #1)3.  With a volt meter, verify that power is o to the      light xture.4.  Place Light Controller in the desired location and      secure with the magnets on the rear of the Light      Controller or screw it down.5.  Disconnect the hot wire to the ballast               (black for 120 VAC or brown for 277 VAC).6.  Connect the black wire on the Light Controller      wires to the hot wire (black for 120 VAC or brown      for 277 VAC) using a wiring connector (see wiring      diagram #1 for one relay and wiring diagram #2      for two relays).   7.  Connect the blue wire on the Light Controller      to the black wire on the ballast using a wiring      connector. For the LC-2R, connect the red wires                     as shown in wiring diagram #2.8.  Connect the white wire on the Light Controller      to the white wire on the ballast and to the white      wire on the incoming power wiring using a        wiring connector. 9.  Bend wires into place such that ballast cover      can easily be reattached.10.Reattach the ballast cover and close the      luminaire cover.11. Switch power on to the xture.  Lights should       turn on.12.Refer to the setup application instructions for       information on programming the light       controller.  Dimming Control (LC-1RD)(See wiring diagram #3)CAUTION: LOW VOLTAGE WIRING MUST BE TREATED AS CLASS 11.   Connect the gray wire on the LC-1RD to the gray       wire or gray terminal on the dimming ballast.2.   Connect the violet wire on the LC-1RD to the       violet wire or violet terminal on the dimming       ballast.3.   When switched on, lamps should turn on to full       brightness. (Approximately 10 VDC signal on the       violet wire to ground).    Dimensions:6 11/16”7 5/8”1”Wiring Diagram #1 LC-1RFIGURE #1ADURA TECHNOLOGIES™San Francisco, CA 94105Tel: 415.227.0868 • Toll Free 1-888-828-8281TM120 VAC /277 VACEXISTING WIRING EXISTING WIRINGEXISTING WIRING EXISTING WIRINGBALLAST HNLC-1RWHITENBLACKBLUEWHITEBLACKWiring Diagram #3 LC-1RDWiring Diagram #2 LC-2R120 VAC /277 VACREDREDBLACKWHITEBLUEBALLAST #2NHNLC-2RWHITENEXISTING WIRING EXISTING WIRINGEXISTING WIRING EXISTING WIRINGEXISTING WIRING EXISTING WIRINGEXISTING WIRING EXISTING WIRING120 VAC /277 VAC BLACK BALLAST #1NHBLACKWHITE120 VAC /277 VACEXISTING WIRINGEXISTING WIRINGEXISTING WIRINGNLC-1RDBALLAST (0-10VDC DIMMING)HNBLACKWHITEBLUEBLACKWHITEGRAYVIOLETEXISTING WIRINGLOW VOLTAGE (MUST BE TREATED AS CLASS 1 WIRING)

Navigation menu