Airspan Networks MMAX5725 WiMAX base station User Manual Air4G Installation Guide
Airspan Networks Inc WiMAX base station Air4G Installation Guide
user manual
UGD-D00236 Rev B Air4Gp Installation Guide Air4Gp Installation Guide Copyright © Copyright by Airspan Networks Inc., 2012. All rights reserved worldwide. The information contained within this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Inc. rights in the aforesaid information. Neither this document nor the information contained herein may be published, reproduced or disclosed to third parties, in whole or in part, without the express, prior, written permission of Airspan Networks Inc. In addition, any use of this document or the information contained herein for the purposes other than those for which it is disclosed is strictly forbidden. Airspan Networks Inc. reserves the right, without prior notice or liability, to make changes in equipment design or specifications. Information supplied by Airspan Networks Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Airspan Networks Inc. for the use thereof nor for the rights of third parties which may be effected in any way by the use of thereof. Any representation(s) in this document concerning performance of Airspan Networks Inc. product(s) are for informational purposes only and are not warranties of future performance, either expressed or implied. Airspan Networks Inc. standard limited warranty, stated in its sales contract or order confirmation form, is the only warranty offered by Airspan Networks Inc. in relation thereto. This document may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed in relation thereto unless specifically undertaken in Airspan Networks Inc. sales contract or order confirmation. Information contained herein is periodically updated and changes will be incorporated into subsequent editions. If you have encountered an error, please notify Airspan Networks Inc. All specifications are subject to change without prior notice. Product performance figures quoted within this document are indicative and for information purposes only. Page 2 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Table of Contents Copyright .......................................................................................................................................... 2 Table of Contents ............................................................................................................................. 3 Summary of Figures ......................................................................................................................... 6 Summary of Tables .......................................................................................................................... 7 Warnings and Cautions .................................................................................................................... 8 Human Exposure to Radio Frequencies ...................................................................................... 8 Radio Interference ........................................................................................................................ 8 Avoiding Radio Interference ......................................................................................................... 8 Modifications ................................................................................................................................. 8 General ......................................................................................................................................... 8 Safety ............................................................................................................................................ 8 Warning Symbols.......................................................................................................................... 9 Service Information ....................................................................................................................... 9 UL Information .............................................................................................................................. 9 Lightning Protection .................................................................................................................... 10 AVERTISSEMENTS ET MISES EN GARDE ................................................................................. 11 ActionΝdesΝradiofréquencesΝsurΝl’organismeΝhumain.................................................................. 11 Brouillage radioélectrique ........................................................................................................... 11 Eviter le brouillage radioélectrique ............................................................................................. 11 Modifications ............................................................................................................................... 11 Généralités ................................................................................................................................. 11 Clause de non responsabilité du fabricant ................................................................................. 11 DECLARATION OF CONFORMITY ............................................................................................... 13 FCC Notice ..................................................................................................................................... 14 Federal Communication Commission Notice ............................................................................. 14 GPS Compliance ........................................................................................................................ 14 Maximum Output TX Power ........................................................................................................... 15 Power Consumption ................................................................................................................... 15 Optional External Antenna Types ............................................................................................... 15 Optional External Antenna Usage .......................................................................................... 15 About this Guide ..................................................................................................................... 16 1.1 Purpose .......................................................................................................................... 16 1.2 Intended Audience .......................................................................................................... 16 1.3 Conventions .................................................................................................................... 16 1.4 Referenced Documentation ............................................................................................ 16 1.5 Organization of this Guide .............................................................................................. 16 Introduction ............................................................................................................................. 18 2.1 Page 3 Air4Gp ............................................................................................................................. 18 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide 2.1.1 Verify Prerequisites................................................................................................................. 20 3.1 Verify Safety Requirements ............................................................................................ 20 3.1.1 3.2 3.2.1 Verify the Tools ....................................................................................................... 21 3.2.2 Verify the Parts and Kits ......................................................................................... 21 3.2.3 Components ........................................................................................................... 24 Install Air4Gp .......................................................................................................................... 27 4.1 Pole mount configuration ................................................................................................ 27 4.2 Wall mount configuration ................................................................................................ 29 4.3 Air4Gp Connections........................................................................................................ 29 4.4 Install Antenna ........................................................................................................ 30 4.5 Antenna Connections (Optional) .................................................................................... 31 4.6 GPS Antenna Assembly ................................................................................................. 31 4.6.1 Mounting GPS Directly on Air4Gp .......................................................................... 31 4.6.2 Remote Mounting of GPS Antenna ........................................................................ 32 4.7 LED Display .................................................................................................................... 33 Connect and Manage Cables ................................................................................................. 35 5.1 Assemble Ethernet Connector ........................................................................................ 35 Set Power System .................................................................................................................. 36 6.1 LED Display ............................................................................................................ 30 Installing Optional External Antenna .............................................................................. 30 4.4.1 Warning of Hazardous Voltages ............................................................................. 20 Verify Installation Requirements ..................................................................................... 21 4.3.1 Architecture ............................................................................................................. 18 Power Input - DC ............................................................................................................ 36 POE (outdoor) Installation ...................................................................................................... 36 7.1 Protection Earth (Ground) Connection ........................................................................... 36 7.2 DC Power Connection .................................................................................................... 37 7.3 PoE Connection .............................................................................................................. 37 7.4 Network Connection ....................................................................................................... 37 7.4.1 Shielded Cables ...................................................................................................... 37 7.4.2 Attachment .............................................................................................................. 37 7.4.3 Waterproofing ......................................................................................................... 37 7.4.4 AC/DC PSU Attachment ......................................................................................... 37 7.5 Earth (Ground) Cable Assembly, MU687-00-028 .......................................................... 39 Cable assembly, DC-PoE-ODU-Air4Gp / 902-00-270............................................................ 40 Initial WEB Configuration ........................................................................................................ 41 9.1 Initial configuration .......................................................................................................... 41 9.1.1 General Config ........................................................................................................ 41 9.1.2 NMS Config ............................................................................................................ 42 Page 4 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide 9.1.3 Mgmt IP Config ....................................................................................................... 42 9.1.4 BS Operational State .............................................................................................. 43 10 Appendix A – Glossary of Terms ........................................................................................ 45 11 Appendix B ......................................................................................................................... 47 11.1 Revision History .............................................................................................................. 47 11.2 31BContact Information ........................................................................................................ 47 Page 5 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Summary of Figures Figure 1 – Air4Gp – network interface ............................................................................................ 19 Figure 2 - PS – Air4Gp ................................................................................................................... 24 Figure 3 – Air4Gp Base Station Unit .............................................................................................. 25 Figure 4 – Air4Gp Base Station Unit, bottom ................................................................................. 25 Figure 5 – Air4Gp Cable Assembly for GPS Antenna .................................................................... 26 Figure 6 - Lightning/Surge protector (required) .............................................................................. 26 Figure 7 - TNC right angle to TNC cable ........................................................................................ 26 Figure 8 – Pole Mounted Air4Gp Assembly ................................................................................... 27 Figure 9 - position mounting assembly on the pole ........................................................................ 28 Figure 10 - Air4Gp Pole mounting - exploded view ........................................................................ 28 Figure 11 – Wall Mounted Air4Gp .................................................................................................. 29 Figure 12 - Air4Gp connections (bottom) ....................................................................................... 30 Figure 13 - Air4Gp Antenna (example) Mast Mount Configuration ................................................ 30 Figure 14 - GPS cable assembly prior to mounting ........................................................................ 32 Figure 15 - Attach GPS antenna to RG58 cable ............................................................................ 32 Figure 16 - GPS antenna assembled on bracket ........................................................................... 32 Figure 17 - Clear sky conditions ..................................................................................................... 33 Figure 18 - minimal distance .......................................................................................................... 33 Figure 19 - GPS Remote mounting ................................................................................................ 33 Figure 20 – Ethernet connector cable termination ......................................................................... 35 Figure 21 – Ethernet environmental connector assembly .............................................................. 35 Figure 22 – DC Power connection.................................................................................................. 36 Figure 23 - Power connector – Air4Gp panel ................................................................................. 36 Figure 24 - DC-PoE-ODU-Air4Gp/902-00-270 ............................................................................... 38 Figure 25 - DC-PoE-ODU-Air4Gp – open ...................................................................................... 38 Figure 26 - DC-PoE-ODU-Air4Gp - punch down tool .................................................................... 39 Figure 27 – General BS Configuration Initial .................................................................................. 41 Figure 28 - SNMP Initial Configuration ........................................................................................... 42 Figure 29 - Management IP Configuration ..................................................................................... 43 Figure 30 - Operational State ......................................................................................................... 44 Page 6 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Summary of Tables Table 1 - Air4Gp FCC Maximum Output TX Power ....................................................................... 15 Table 2 - Air4Gp ETSI Maximum Output TX Power ....................................................................... 15 Table 3 - Power Consumption ........................................................................................................ 15 Table 4 - 5.x GHz Antenna Types - Technical ............................................................................... 15 Table 6 - Air4Gp installation tools................................................................................................... 21 Table 7 - Air4Gp installation parts and kits ..................................................................................... 21 Table 8 - GPS Kit Contents ............................................................................................................ 22 Table 9 - Air4Gp Pole/wall mount installation parts ........................................................................ 23 Table 10 - Air4Gp additional parts and kits .................................................................................... 24 Table 11 - Input Power for Air4Gp .................................................................................................. 24 Table 12 - Air4Gp physical dimensions .......................................................................................... 25 Table 13 - LED Display ................................................................................................................... 34 Page 7 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Warnings and Cautions Human Exposure to Radio Frequencies The Air4Gp should be installed and operated from a minimum distance of 2 meters from your body. Radio Interference This Air4Gp generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the technician is encouraged to try to correct the interference by performing one or more of the following measures: Re-orientate or relocate the antenna Increase separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the power source is connected Avoiding Radio Interference Ensure a minimum of 1-meter separation between co-located antennas of Air4Gp units. Modifications Any changes and modifications to this device that are not expressly approved by Airspan Networks may void the user's authority to operate the equipment. General Only qualified personnel should be allowed to install, replace, and service the equipment. The device cannot be sold retail, to the general public or by mail order. It must be sold to operators. Installation must be controlled. Installation must be performed by licensed professionals. Installation requires special training. The Air4Gp radio and antenna should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void Airspan's WiMAX product warranty and may expose the end user or the service provider to legal and financial liabilities. Airspan and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas. Safety 1. Read this User Manual and follow all operating and safety instructions. 2. Keep all product information for future reference. 3. This product is supplied with a grounding power plug. Do not defeat this important safety feature. 4. Warning: High voltages exist inside the product - do not remove any cover or base: No user serviceable parts inside. 5. Position the power cord to avoid possible damage; do not overload wall outlets. Page 8 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide 6. Do not place this product on or near a direct heat source, and avoid placing objects on the terminal. 7. Do not operate this device near water or in a wet location. 8. Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the power before cleaning. 9. The units should not be located near power lines or other electrical power circuits. 10. The radio transceiver must be properly grounded to protect against power surges and accumulated static electricity. ItΝisΝtheΝuser’sΝresponsibilityΝtoΝinstallΝthisΝdeviceΝinΝ accordance with the local electrical codes. 11. Installation of the Air4Gp must be contracted to a professional installer. 12. Disconnect Device. The socket outlet should be easily accessible in case you have to disconnect the device. 13. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. Warning Symbols The following symbols may be encountered during installation or troubleshooting. These warning symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and radio transmitters. Familiarize yourself with standard safety practices before continuing. Electro-Magnetic Radiation High Voltage Service Information Refer all repairs to qualified service personnel. Do not remove the covers or modify any part of this device, as this will void the warranty. Disconnect the power to this product and return it for service if the following conditions apply: a. The terminal does not function after following the operating instructions outlined in this manual. b. Liquid has been spilled, a foreign object is inside, or the terminal has been exposed to rain. c. The product has been dropped or the housing is damaged. Locate the serial number of the terminal, antenna, and transceiver and record these on your registration card for future reference. Use the space below to affix serial number stickers. Also record the MAC address, located on the back of the terminal. UL Information - The equipment must be properly grounded according with NEC and other local safety code requirements. - Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC which provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as is practical. Page 9 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Lightning Protection WARNING: The following notes are general recommendations for the system. The wireless equipment should be installed by a qualified professional installer and must follow local and national codes for electrical grounding and safety. Failure to meet safety requirements and/or use of non-standard practices and procedures could result in personal injury and damage to equipment. A direct lightning strike may cause serious damage even if these guidelines are followed. All outdoor wireless equipment is susceptible to lightning damage from a direct hit or induced current from a near strike. Lightning protection and grounding practices in local and national electrical codes serve to minimize equipment damage, service outages, and serious injury. Reasons for lightning damage are summarized as: - Poorly grounded tower/antenna sites that can conduct high lightning strike energy into equipment. - Lack of properly installed lightning protection equipment that can cause equipment failures from lightning induced currents. A lighting protection system provides a means by which the energy may enter earth without passing through and damaging parts of a structure. A lightning protection system does not prevent lightning from striking; it provides a means for controlling it and preventing damage by providing a low resistance path for the discharge of energy to travel safely to ground. Improperly grounded connections are also a source of noise that can cause sensitive equipment to malfunction. A good tower grounding system disperses most of the surge energy from a tower strike away from the building and equipment. To limit the equipment damage due to a lightning strike, the following practices are recommended for the wireless system: - Provide direct grounding from the antenna mounting bracket, the radio and antenna and the lightning arrestors to the same ground point at the base of the tower or a ground bus on the building. Use the grounding screws on the antenna bracket and the radio and antenna for terminating the ground wires. - The AC wall outlet ground must be connected to the same grounding system as the BS. Page 10 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide AVERTISSEMENTS ET MISES EN GARDE Action des radiofréquences sur l’organisme humain Le Air4Gp sera installé et exploité à une distance minimum de 2.4 mètres de votre corps. Brouillage radioélectrique CetΝéquipementΝgénère,ΝutiliseΝetΝpeutΝdégagerΝdeΝl’énergieΝradiofréquenceΝs’ilΝn’estΝpasΝinstalléΝ et utilisé conformément aux instructions. Il est susceptible de provoquer des interférences préjudiciablesΝauxΝcommunicationsΝradio.ΝToutefois,ΝnousΝneΝpouvonsΝgarantirΝqu’aucuneΝ interférenceΝneΝseΝproduiraΝdansΝleΝcadreΝd’uneΝinstallationΝparticulière.ΝSiΝcetΝéquipement dégage des interférences préjudiciables à la réception radiophonique ou télévisuelle, qui peuvent être détectéesΝenΝallumantΝouΝenΝéteignantΝl’appareil,Νl’utilisateurΝestΝinvitéΝàΝessayerΝdeΝcorrigerΝleΝ problèmeΝenΝprenantΝl’uneΝouΝl’autreΝdesΝmesures suivantes : RéorientezΝouΝdéplacezΝl’antenneΝdeΝréception. AugmentezΝlaΝdistanceΝentreΝl’équipementΝetΝleΝrécepteur. BranchezΝl’équipementΝsurΝuneΝpriseΝdifférente,ΝdeΝmanièreΝàΝceΝqueΝl’équipementΝetΝ leΝrécepteurΝsoientΝbranchésΝsurΝdesΝcircuitsΝd’alimentation différents. Consultez le distributeur ou un technicien radio/TV expérimenté pour obtenir de l’aide. Eviter le brouillage radioélectrique Cet émetteur ne sera ni co-positionné, ni exploité simultanément avec une autre antenne ou un autre émetteur. Prévoyez une séparation minimum de 1 mètre entre les BSR co-positionnés. Modifications ToutΝchangementΝouΝmodificationΝàΝceΝdispositif,Νn’étantΝpasΝexpressémentΝapprouvéΝparΝAirspanΝ NetworksΝpeutΝentraînerΝl’arrêtΝauΝdroitΝdeΝl’utilisateurΝàΝfaireΝfonctionner cet équipement. Généralités Seul du personnel qualifié sera autorisé à installer, remplacer et maintenir cet équipement. Le dispositif ne peut être vendu au détail au grand public ou par correspondance. Il doit être vendu aux distributeurs. L’installation doit être vérifiée. L’installationΝseraΝeffectuéeΝparΝunΝprofessionnelΝmuniΝd’uneΝlicence. L’installationΝrequiertΝuneΝformationΝparticulière. LaΝradioΝetΝl’antenneΝAir4GpΝneΝserontΝinstalléesΝQUEΝparΝdesΝprofessionnelsΝ expérimentés, familiarisés avec les normes et règlements de constructions et exigencesΝsécuritairesΝlocaux,ΝsiΝapplicable,ΝdétenteursΝd’uneΝlicenceΝdélivréeΝparΝlesΝ autorités de régulation gouvernementales appropriées. Un manquement à ce qui précèdeΝpourraitΝentraînerΝl’annulationΝdeΝla garantie attribuée au produit WiMAX d’AirspanΝetΝexposerΝl’utilisateurΝouΝleΝfournisseurΝdeΝservicesΝàΝdesΝsanctionsΝlégalesΝ ou financières. Airspan et ses revendeurs ou distributeurs ne pourront être tenus responsables de toute blessure, endommagement ou violation des règles liées à l’installationΝdesΝunitésΝouΝantennesΝextérieures. Clause de non responsabilité du fabricant Toutes les informations contenues dans ce document sont sujettes à des changements sans préavis et ne constitueront en aucun cas, un engagement de la part du vendeur. Aucune déclarationΝneΝseraΝfaiteΝouΝaucuneΝgarantieΝneΝseraΝaccordée,Νqu’elleΝsoitΝexpresse ou tacite Page 11 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide quantΝàΝlaΝqualité,Νl’exactitudeΝouΝlaΝcapacitéΝàΝremplirΝunΝobjectifΝparticulierΝdeΝceΝdocument.ΝLeΝ fabricantΝseΝréserveΝleΝdroitΝd’effectuerΝtoutΝchangementΝauΝcontenuΝdeΝceΝdocumentΝet/ouΝauxΝ produits qui lui sont liés, à tout moment, sans aucuneΝobligationΝd’enΝinformerΝquiΝqueΝceΝsoit.ΝLeΝ fabricantΝneΝseraΝd’aucuneΝmanièreΝtenuΝresponsableΝdeΝtoutΝdommageΝdirect,Νindirect,Νparticulier,Ν fortuitΝouΝconsécutifΝliéΝàΝl’utilisationΝouΝàΝl’impossibilitéΝd’utiliserΝceΝproduitΝouΝsaΝdocumentation, même si celui-ci a été prévenu de la possibilité de tels dommages. Ce document décrit des matériaux protégés par copyright. Tous les droits sont réservés. Aucune partie de ce manuel ne sera reproduite ou transmise, sous toute forme ou par tout moyen, quel qu’enΝsoitΝleΝbut,ΝsansΝ autorisation écrite de ces auteurs. Les noms de produits apparaissant dans ce document ne sont évoquésΝqu’àΝtitreΝindicatif.ΝToutesΝlesΝmarquesΝcommerciales,ΝtousΝlesΝnomsΝdeΝproduitΝouΝdeΝ marques apparaissant dans ce document appartiennent à leur propriétaire respectif. Page 12 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide DECLARATION OF CONFORMITY European Community, Switzerland, Norway, Iceland, and Liechtenstein Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC English: This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Deutsch: Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der Richtlinie 1999/5/EU. Dansk: Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv 1999/5/EF. Español: Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC. Greek: Μ ΝΣΗΝΝΠΑΡΟΤΑΝAirspanΝ ΗΛΩΝ ΙΝΟΣΙΝΟΝ ΞΟΠΛΙΜΟΝΤΜΜΟΡΦΩΝ ΣΑΙΝΠΡΟΝΣΙΝ ΟΤΙΩ ΙΝΑΠΑΙΣΗ ΙΝΚΑΙΝΣΙΝΛΟΙΠ ΝΧ ΣΙΚ Ν ΙΑΣΑΞ ΙΝΣΗΝΟ ΗΓΙΑΝ1999/5/ Κ.Ν Français: Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC. Íslenska: Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB. Italiano: Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC. Nederlands: Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC. Norsk: Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EUdirectiv 1999/5/EC. Português: Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC. Suomalainen: Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen. Svenska: Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i Direktiv 1999/5/EC. Român: AcestΝechipamentΝesteΝînΝconformitateΝcuΝcerinţeleΝesenţialeΝşiΝalteΝprevederiΝrelevanteΝaleΝ Directivei 1999/5/CE. The Declaration of Conformity related to this product can be obtained from product_management@Airspan.com 92H Page 13 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide FCC Notice Federal Communication Commission Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. Fixed and base stations transmitting a signal with an emission bandwidth greater than 1 MHz must not exceed an ERP of 1000 watts/MHz and an antenna height of 305 m HAAT, except that antenna heights greater than 305 m HAAT are permitted if power levels are reduced below 1000 watts/MHz ERP. GPS Compliance The GPS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC." The GPS complies with the following EMC Common Regulatory Testing standards: EN55022: Radiated and Conducted Emissions CISPR 22: Class B EN 50081-1: Generic Emissions Class B EN 50082-1: Generic Immunity Class B EN 61000-4-2: Electrostatic Discharge Immunity EN 61000-4-3: Radiated RF EM Field Immunity Test EN 61000-4-4: Electrical Fast Transient/Burst Test EN 61000-4-6: Conducted Immunity EN 61000-4-8: Magnetic Field Immunity Note: A GPS is required for synchronizing between TDD sectors. Note: A GPS Lightning/Surge protector is required. Page 14 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Maximum Output TX Power Table 1 - Air4Gp FCC Maximum Output TX Power Frequency Band FCC TX 5.725-5.850 GHz Antenna Gain EIRP 19.48 dBm 35.98 dBm 16.5 dBi Table 2 - Air4Gp ETSI Maximum Output TX Power Frequency Band ETSI TX 5.47-5.95 GHz EIRP 10.5 dBm 27 dBm Rest of the World TX EIRP 28 dBm Antenna Gain 44.5 dBm 16.5 dBi Caution: Do not set maximum output TX power to higher than local regulations. Power Consumption Table 3 - Power Consumption Air4Gp Watts 5.x 75 Max Optional External Antenna Types Table 4 - 5.x GHz Antenna Types - Technical Type Frequency range Gain Part number Dual Slant ± 45 degrees 90 Sector 4.9 - 6.1 GHz 16.5dBi SEC90X-5.X-RC-1 Optional External Antenna Usage Air4Gp has two (2) RF ports for external antenna usage that can be connected to optional external antenna. Note: Appropriate mounting kit (included) for the antenna required. Page 15 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide About this Guide This section discusses the purpose, intended audience, conventions, referenced documentation and organization for this guide. 1.1 Purpose This guide provides the workflow and step-by-step procedures for Installing the Air4Gp. These procedures include: Verify Prerequisites Install the Air4Gp Connect and Manage Cables Install and set Power System 1.2 Intended Audience This guide is intended for persons who are responsible for Installing the Air4Gp. These persons should have a working knowledge of the WiMAX system. 1.3 Conventions This document uses the following informational conventions. Icon Description Checkpoint: Marks a point in the workflow where there may be an exit or branch to some other procedure. At each Checkpoint the reason for an exit or branch is given along with specific directions to locate the entry point in the other procedure. Reference: Gives a resource in the workflow that may be needed to complete a procedure along with specific directions to use the resource. Caution: Describes a possible risk and how to lessen or avoid the risk. Advice: Provides a recommendation based on best practice. Note: Provides useful information. 1.4 Referenced Documentation Air4Gp Overview Guide Air4Gp Product Description 1.5 Organization of this Guide This guide is organized into the following Sections: About this Guide Introduction Verify Prerequisites Install the Air4Gp Connect and Manage Cables Install and set Power System Page 16 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Appendixes [Securing & Connecting the cable, Glossary of Terms, Contact information and Revision history] Page 17 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Introduction This section provides a descriptive overview of the Air4Gp and its place in the product suite. 2.1 Air4Gp Air4Gp is a dual protocol compact Base Station: WiMAX (IEEE802.16e) Base Station and simultaneously an LTE eNodeB. The Air4Gp is a Pico base station operating on unlicensed frequency bands and can support up to 4 carriers that can be deployed to cover a single sector or two distinct sectors. It can run either WiMAX or LTE or both WiMAX and LTE. It includes integrated quad transmitters to support four channel diversity and MIMO with an optional integrated dual slant antenna. It is a highly integrated compact base station with all-in-one packaging of RF and base-band components. It is available mounted outside on a pole or wall. Air4Gp is available in frequencies between 150 MHz and 6 GHz and in numerous channels . Air4Gp currently operates in the 5.x frequency band and was designed to overcome harsh interference conditions due to its 4x4 MIMO capability. The Tx power of the Air4Gp is limited to 22dBm, or 27dBm (depending on the variant), to meet unlicensed band regulations. Air4Gp can run WiMAX, LTE or WiMAX and LTE simultaneously. Air4Gp is managed by an SNMP-based network management system (Netspan) using standard and proprietary MIBs. Basic management can be performed using any standard Web browser. Note: The channel bandwidth describes the maximum bandwidth. Partial bands can also be utilized. Note: For management refer to Air4Gp Commissioning documentation. 2.1.1 Architecture A highly flexible and scalable WiMAX Base Station, the Air4Gp is capable of supporting WiMAX profiles across multiple frequency bands. Note: The following is for illustration only; actual layout may differ as infrastructure is installation-specific. Note: Air4Gp must be properly grounded according with NEC and other local safety code requirements. Note: Installation of the GPS Lightning/Surge protector is necessary to protect the GPS antenna. Example of three (3) sectors is illustrated below: Page 18 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 1 – Air4Gp – network interface Note: Auto-negotiation must always be enabled on the core network side. Note: Illustration above displays the GPS connected directly to the top of the units there is also a remote GPS antennae option. Page 19 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Verify Prerequisites Prior to installing the Air4Gp, verify the required safety, power, tools, parts and components. 3.1 Verify Safety Requirements Read and follow all warning notices and instructions marked on the product or included in this manual. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. Ascertain the radiation hazards when working in an environment close to other antennas and Electromagnetic fields, e.g. working on towers with other microwave transmitters etc. and act accordingly. 3.1.1 Warning of Hazardous Voltages On AC installations, hazardous voltages exist. Use caution when verifying or working with AC power. Remove metal jewelry that could come into contact with AC power. On DC sections, short circuiting the low voltage, low impedance circuits can cause severe arcing that may result in burns or eye damage. Remove rings, watches etc. to avoid shorting DC circuits. Note: Airspan products do not contain hazardous substances (as defined in UK Control of Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990). At the end of any Airspan products life cycle, the customer should consult with Airspan to ensure that the product is disposed of in conformance with the relevant regulatory requirements. Caution: Any modifications to this device not expressly authorized by the manufacturer could void the user’s authority to operate this device. Page 20 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide 3.2 Verify Installation Requirements 3.2.1 Verify the Tools Table 5 - Air4Gp installation tools Tool Large Crosshead Screw driver Phillips # 3 or Pozidrive # 3 Small flat blade screwdriver Medium flat blade screwdriver 13mm or 1/2 inch open ended spanner 10mm or 13/32 inch open ended spanner Wire strippers Wire cutters Ring terminals crimp tool RJ45 crimp tool 3.2.2 Verify the Parts and Kits Table 6 - Air4Gp installation parts and kits Air4Gp Base Station parts Consisting of 1 x Air4Gp unit Base station unit 1x RJ45 Weatherproof Connector Cover Weatherproof connector cover for use with standard CAT5e RJ45 network connections. 1 x mains cable 14AWG x2 (ordered separately) 30 meter lead with M17 3 pole plug 1 x Ethernet RJ45 environmental shroud LTW IP68 or Amphenol environmental connector There are two (2) options for a POE (Power over Ethernet), either an internal POE or an external POE usage to be determined by field requirements. 1 x POE Indoor – AC-PoE100-IDU-Air4Gp 1 x POE Outdoor – DC-PoE-ODU-Air4Gp / 902-00-270 Page 21 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Air4Gp Base Station parts Consisting of 1 x Air4Gp installation Pole/Wall mounting kit Tilting panel (ordered separately) 402-00-184 1) Interface Bracket - Left 402-00-185 2) Interface Bracket - Right 402-00-186 402-00-188 Back bracket Screw - M8 x 200 Hex SST AISI 304 – 4 Screw - M8 x 20 Hex SEMS SST 304 - 8 Flat washer - M8 DIN125 SST 304 - 10 Spring washer - M8 DIN 127 SST 304 - 6 Nut - M8 Hex DIN127 - 6 1 x earth kit 1 x M5 screws 1 x M5 washers 1 x M5 spring washers Alternative: SEMS screw (includes 2 washers) Type-IC DC Power Cable Available either in - 10, 15 or 30 meter lengths. Additional lengths available. Grounding Cable (required) (not included) Circular earth braid, 120A current (16 mm²), jacketed or not with cable size = AWG 4 – 6 with lug (terminal) on enclosure side with hole M6 The following table displays the parts contained in the included GPS Kit and when the parts are required per configuration. See GPS Antenna Assembly = required when applicable for this configuration X = not required in this configuration Table 7 - GPS Kit Contents Part Description Air4G Air4Gp Air4Gs Image Ext. Int. GPS Antenna 80cm GPS Cable - RG58 TNC-TNC See Optional Cables Remote GPS Antenna Mounting Bracket Page 22 1 x GPS Antenna. An active GPS antenna which, with the appropriate mounting bracket is used with the BS for network synchronization. For mounting the GPS directly to the top of the BS. Should be used in conjunction with the BS GPS antenna mounting bracket preassembled on the BS. Used in conjunction with the long GPS Cable - when mounting GPS remotely. (see optional cables below) Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Part Description Air4G Air4Gp Air4Gs Image Ext. Int. Lightning/Surge Surge Protector designed to protect protector from lightning strikes. 30cm Surge to For connecting the Surge protector BS Cable to the Base Station. (RF cable assy TNC to TNC- RA,30cm,RG58) Protector mounting bracket For mounting the Surge protector to the BS. Protector For clamping the bracket to the BS. mounting Includes necessary hardware. bracket clamp An additional mounting bracket included in the packaging is not required for use. Optional Cables 16m GPS Cable - RG58 TNC-TNC - For mounting remotely from the base station unit. Should be used in conjunction with the Remote GPS Antenna Mounting Bracket - P/N CBL-GPS-TNC-16-1 40m GPS Shielded Cable TNC-TNC for remote GPS mounting option. An optional shielded cable for when excessive interference is detected, such as strong TV transmission interference.– P/N CBL-GPS-TNC-40-1 Note: For additional cable lengths contact your Airspan representative. Table 8 - Air4Gp Pole/wall mount installation parts Parts Part no. Tilting panel 402-00-184 Interface Bracket - Left 402-00-185 Interface Bracket - Right 402-00186 Page 23 Commercial in Confidence Images UGD-D00236 Rev B Air4Gp Installation Guide Parts Part no. Back bracket x2 402-00188 GPS Antenna mounting bracket Images Table 9 - Air4Gp additional parts and kits Additional Common Accessories (not provided by Airspan) Spare RJ45 connectors Cable ties Ring terminal for earth strap. M5 / M6 Earth strap cable (4-6 mm) (yellow and green cable) Weatherproof / Outdoor mains cable splice kit or termination box. The Air4Gp power supply (PS) can be installed with various cable lengths according to the site requirements. The cable lengths are determined by the length of the run between the PS and the Air4Gp. Use the following table to determine the required power supply output to ensure proper operation of the Air4Gp. Table 10 - Input Power for Air4Gp Air4Gp (1) Input Voltage to Air4Gp -48 VDC to -60 VDC Figure 2 - PS – Air4Gp 3.2.3 Components Air4Gp is shown below from the front view and bottom view displaying the connections. Page 24 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 3 – Air4Gp Base Station Unit Figure 4 – Air4Gp Base Station Unit, bottom 3.2.3.1 Physical Dimensions Air4Gp BS is in an all outdoor enclosure. Table 11 - Air4Gp physical dimensions Parameter Value Comment Height 394.8 mm (15.54 inches) Width 371.3 mm (14.62 inches) Depth 123.5 mm (4.86 inches) Weight Aprox. 10 kg (2.2 lbs.) Page 25 The physical dimensions exclude handles and connectors. Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide RF Ports for antenna connections are N-Type Female connectors located on the bottom of the Air4Gp enclosure. Adjacent to these are SMA connectors used for RF monitoring purposes during installation / maintenance. For normal operation, these are covered with a weatherproof cap. An 80cm, cable connects the GPS directly to the top of Air4Gp. When mounting the GPS antenna remotely from the base station unit, the GPS antenna should be used in conjunction with the Remote GPS Antenna Mounting Bracket (GPS-MNT-1) and either the 16m (CBL-GPS-TNC-16-1) or the 40m (CBL-GPS-TNC-40-1) GPS Cable RG58 TNC-TNC by way of TNC connectors. The cable assembly for the remote GPS antenna is shown below. Figure 5 – Air4Gp Cable Assembly for GPS Antenna Figure 6 - Lightning/Surge protector (required) Figure 7 - TNC right angle to TNC cable Page 26 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Install Air4Gp Install the Air4Gp base station by pole mount or wall mount. Caution: Proper local rigging and hoisting practices should be followed when installing the Air4Gp. The pre-assembled handles are not to be used for hanging, attaching or hoisting the unit into place. 4.1 Pole mount configuration The following image shows the pole mount assembly. Figure 8 – Pole Mounted Air4Gp Assembly To mount the Air4Gp on the pole mount configuration, perform the following steps: 1. Assemble the 4 threaded bolts (M8 x 200) onto the Tilting panel and hand-tighten M8 nuts onto the threaded bolts (on the outer side). 2. Assemble the 2 interface brackets (left and right) with their threaded pin facing outwards (in the up position) to the threaded holes on the Air4Gp back. 3. Attach the GPS on to the GPS antenna bracket and attach to the top of the Air4Gp. 4. Assemble the two (2) Back brackets onto the Tilting panel to properly fit on the pole. 5. Align and position each of the 2 back brackets at the proper height to attach the Air4Gp (with the Tilting panels pivot grooves facing up). Adjust the upper bracket and tighten in place. Adjust the lower bracket and hand-tighten. Page 27 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 9 - position mounting assembly on the pole 6. Fasten the surge protector into the provided hole (in the Tilting panel) and hand-tighten. 7. Carefully align and position the Air4Gp unit so that the threaded pins (1 on each the Interface bracket) fit into the notched grooves provided on the Tilting panel and hand tighten. Insert the M8 screws, washers and nuts (supplied) and fasten to the Tilting panel. Caution: The unit weighs about 10 kg take care when lifting. 8. Adjust the unit to the desired angle. 9. Check and tighten all fixing screws. Figure 10 - Air4Gp Pole mounting - exploded view Page 28 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide 4.2 Wall mount configuration The following image shows the wall mount assembly. Figure 11 – Wall Mounted Air4Gp To mount the Air4Gp in the wall mount configuration, perform the following steps: 1. Attach the Tilting panel to the wall at the height required to attach the Air4Gp using wall plugs rated for at least 10 Kg. 2. Assemble the 2 interface brackets (left and right) with their threaded pin facing outwards (in the up position) to the threaded holes on the rear side of the Air4Gp. 3. Attach the GPS on to the GPS antenna bracket and attach to the top of the Air4Gp. 4. Fasten the surge protector into the provided hole (in the Tilting panel) and hand-tighten. 5. Carefully align and position the Air4Gp unit so that the threaded pins (1 on each the Interface bracket) fit into the notched grooves provided on the Tilting panel and hand tighten. Insert the M8 screws, washers and nuts (supplied) and fasten to the Tilting panel. Caution: This unit weighs 10 kg take care when lifting. 6. Adjust the unit to the desired angle. 7. Check and tighten all fixing screws. 4.3 Air4Gp Connections The following diagram displays the connections on the bottom side of the Air4Gp. The base station requires a secure ground connection. The cable should also be grounded to the tower which is grounded at the tower base. A grounding screw fitted with a flat washer and lock washer is provided on the bottom of the chassis clearly marked with the universal ground symbol as shown below. Page 29 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 12 - Air4Gp connections (bottom) Note: Previous versions had 3 RJ45 (Ethernet) connections. 4.3.1 LED Display TheΝLED’sΝare a visual display to indicate basic BS status, see LED Display below for a description of the LED display. 4.4 Installing Optional External Antenna Use this procedure to install optional external antenna for the Air4Gp in the mast mount configuration. 4.4.1 Install Antenna Figure 13 - Air4Gp Antenna (example) Mast Mount Configuration Page 30 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Note: Mounting kit is included. To mount the antenna for the Air4Gp in the mast mount configuration, perform the following steps: 1. Attach the Antenna brackets to the top and bottom of the radome. 2. Attach the tilt arm to the top bracket of the radome. 3. Fasten the ends of the adjustable pipe mounts to the top and bottom brackets of the radome. 4. Lift the radome and place the screws through the adjustable pipe mounts and position the radome so that the top mounting holes retain the unit. 5. Screw the bottom two screws and washers into the two standoff fittings at the bottom of the radome assembly. 6. Tighten all fixing screws. 7. Attach, connect and secure antenna RF cable between the antenna and the appropriate Air4Gp Antenna RF connection on the top of the unit. 4.5 Antenna Connections (Optional) Caution: Antennas must be connected and attached before Air4Gp is powered on. Caution: Attach the appropriate cable to the antenna and hand-tighten. Torque the N-Type connector to 6.2 - 9.7 in-lbs or 0.7 - 1.1 N-m using either a 19mm or 13/16”ΝopenΝendΝTorqueΝwrenchΝ(dependingΝonΝcouplingΝtype). Caution: Power down Air4Gp prior to disconnecting antenna. 4.6 GPS Antenna Assembly The GPS antenna should be installed far from: High-voltage power cables. Strong radiation area of any TV transmission stations. Radiation area of the main lobe of the RF Antenna. Radiation area of the microwave antenna. Other areas with inter-frequency interference or strong electromagnetic interference. Cable Fastening Good Practices: No more than 5m between cable fastening spaces. No more than 1m between cable termination and first fastener. FasteningsΝshouldΝbeΝtoΝaΝrobustΝconstructionΝ(i.e.ΝmastΝpole,ΝBSΝmount…). Fasteners should be weather and UV resistant. Cables should have some slack for thermal expansion/contraction between fastenings. 4.6.1 Mounting GPS Directly on Air4Gp To mount the GPS antenna directly on the Air4Gp: 1. Route the RG58 cable through the flat washer and the 2 nuts (supplied). 2. Position the RG58 cable below the mounting hole on the GPS antenna mounting bracket. Page 31 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 14 - GPS cable assembly prior to mounting 3. Hand-tighten the RG58 cable TNC (90°) connector to the mating connector on the GPS antenna. Figure 15 - Attach GPS antenna to RG58 cable 4. Slide the flat washer up to the underside of the mounting bracket, then thread 1 nut onto the GPS antenna threaded base and tightened. 5. The second nut is then secured and tightened against the first nut to create a clamp load against the first nut, as shown below: Figure 16 - GPS antenna assembled on bracket 6. Connect the RG58 cable attached to the GPS to the Lightning/Surge protector (required) which is connected to the TNC to TNC cable to the GPS connection on the bottom Air4Gp. Note: Affix cable to the BS to avoid strain on the connections. 7. Verify that the weatherproof cable is in the proper position and hand tighten the cable (using no tools), to prevent water leakage. Apply self-amalgamating insulating tape on all critical connections. 4.6.2 Remote Mounting of GPS Antenna When mounting the GPS antenna remotely from the base station unit, the GPS antenna should be used in conjunction with the Remote GPS Antenna Mounting Bracket (GPS-MNT-1) and either the 16m (CBL-GPS-TNC-16-1) or the 40m (CBL-GPS-TNC-40-1) GPS Cable RG58 TNC-TNC. Note: Care should be taken so that the remote installation of the GPS antenna shouldΝbeΝdistancedΝfromΝanyΝobstructionsΝthatΝcanΝinterfereΝwithΝ“clearΝsky”Ν conditions. Page 32 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 17 - Clear sky conditions Figure 18 - minimal distance When interference is present the GPS antenna can be installed in a position lower than the base station using the 40m (CBL-GPS-TNC-40-1) shielded GPS Cable. An example displaying the mounting of the GPS antenna on the tower below the Air4Gp is displayed below: Figure 19 - GPS Remote mounting Note: All cables should be properly secured to prevent undue strain on any of the cable terminations. 4.7 LED Display When powering up refer to the following for indication of BS current status: Page 33 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Table 12 - LED Display LED Name Color Status PWR Power Green On Power on Off Power off Alarm detected ALM Alarm Red On NWL Network Link Green Steady on In service Green STA Page 34 Blinking On Description Network link detected Traffic currently flowing Software running Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Connect and Manage Cables The Ethernet cable is connected to the Air4Gp using a standard RJ45 connector protected by a harsh environment protective casing. Figure 20 – Ethernet connector cable termination 5.1 Assemble Ethernet Connector 1. Pass the CAT5e cable through the seal, front connector, body and tail nut of the environmental connector casing as shown above. 2. Paste the front seal on the collar of the connector body. 3. Terminate the Ethernet cable with an RJ45 connector plug. 4. Seat the RJ45 connector plug securely into the body cavity. 5. Tighten the tail nut on to the body forcing the seal to compress around the cable. Figure 21 – Ethernet environmental connector assembly Page 35 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Set Power System Hazardous voltage! Before working, ensure that the power is removed from the power connection cables. When the system is powered on, do not touch the power terminals. 6.1 Power Input - DC Each unit is provided with a 3/10/30 meter 48 volt power cable terminated with a female connector at one end to be connected to the Power connector on the bottom panel of the Air4Gp and bare wires at the other. Caution: It is important that the power connector is attached at the correct end or damage to the connector/equipment will result. Note: Check Power Supply for proper polarization. Figure 22 – DC Power connection Figure 23 - Power connector – Air4Gp panel POE (outdoor) Installation 7.1 Protection Earth (Ground) Connection Connect the protection earth (ground) cable to an Earth rod or Earth plate at equipment building entryΝlocation.ΝUseΝsuitableΝ“PotentialΝhazardΝonΝRemoval”ΝwarningΝlabels.ΝTheΝprotectionΝearth (ground) should always be the first cable connected and the last to be disconnected. Avoid inducing 50Hz Mains hum into the Ethernet pairs through the protection earth from AC Mains earth. Use of a Building Entry Earth Rod is preferred. Page 36 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide 7.2 DC Power Connection Insert the DC cable through the gland cover and O-ring, Strip back 100mm outer sheath. Strip back 5mm from both inner cores. Solder-Tin the inner cores to stop fray when inserting into terminal block. Insert the DC cable and screw to terminal block J3, adhering to polarity indicated. Lay the cable around (not over) J1. 7.3 PoE Connection Strip back 60mm of the outdoor CAT5e sheath. Insert the CAT5e pairs through the glands. Punch-down the CAT5e cable-pairs to the IDC connectors using the punch-down-tool, being careful to conform to the coloring scheme. The Punch-down tool is polarised, so use the cutting scissors of the Tool to the LEFT side of the picture. Shake out all the loose cuttings. 7.4 Network Connection Strip back 60mm of the outdoor CAT5e sheath. Insert the CAT5e pairs through the glands. Punch-down the CAT5e cable-pairs to the IDC connectors, being careful to conform to the coloring scheme. The Punch-down tool is polarised, so use the cutting scissors of the Tool to the RIGHT side of the picture. Do not mix CAT6 for the network and CAT5e for POE, generally stick to all CAT5e or all CAT6. 7.4.1 Shielded Cables It is preferred to use shielded cable. Connect the two drain wires through a cable sheath and ring crimp them to the alternate earth screw (bottom right). 7.4.2 Attachment AttachΝtheΝboxΝusingΝ2ΝoffΝΠ6Ν1”ΝPan-Pozi Self Tapping screws. 7.4.3 Waterproofing Tighten all glands for IP66 seal. Use two spanner wrenches to prevent the barrel rotating. Do not over-tighten the barrel to lock-nut which would have been tightened by the factory. Tighten the Lid for IP66 seal. 7.4.4 AC/DC PSU Attachment Attach the power supply using 4 offΝΠ6Ν0.5”ΝPan-Pozi Self Tapping screws. Page 37 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 24 - DC-PoE-ODU-Air4Gp/902-00-270 Figure 25 - DC-PoE-ODU-Air4Gp – open Connect the Ethernet CAT5e cables into and from the terminal blocks J1 and J2. See Cable assembly, DC-PoE-ODU-Air4Gp / 902-00-270 below. Page 38 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 26 - DC-PoE-ODU-Air4Gp - punch down tool 7.5 Earth (Ground) Cable Assembly, MU687-00-028 681-00-029 , Cut 1 meter of (Lapp 4160500, 14AWG, CSA 2.5mm, Green/Yellow, OD 3.7mm) Strip Back 6mm of one end. 300-60-010. Attach Crimp Ring, Tyco(Amp) 51864-1, #8, M4, OD <=7.9mm, 14AWG, Blue. Page 39 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Cable assembly, DC-PoE-ODU-Air4Gp / 902-00-270 Network_End Number Pin1 White/Orange Pin2 Orange Pin3 Air4Gp_End 25 metres Number Cut and insert POE injector as installation requires Pin1 White/Orange Pin2 Orange White/Green Pin3 White/Green Pin4 Blue Pin4 Blue Pin5 White/Blue Pin5 White/Blue Pin6 Green Pin6 Green Pin7 White/Brown Pin7 White/Brown Pin8 Brown Pin8 Brown Marketing Product Code = DC-PoE-ODU-Air4Gp Packaged Item = 902-00-207 Cable assembly = 687-00-033 Drawing = MU68700033 CAT5e Connector = Amphenol ID550-000 CAT5e = Beldin 7918a 20metres cut from 100m reel 68000038. Qty 2, RJ45 = Molex 449150001 (Cat6 Unscreened Solid) QtyΝ2,ΝLabelΝ=ΝPanduitΝS100X225VADYΝ(text=“687-00-033”)Ν(material=outdoorΝquality) Page 40 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Initial WEB Configuration Configure an Air4Gp base station using the built in web based interface. This prepares the equipment for connection to Netspan. 9.1 Initial configuration To set initial configuration, perform the following: Caution: The GPS antenna should be installed and attached before Air4Gp is powered on. Caution: Wait two minutes before performing other actions. 1. Apply power to the Air4Gp. 2. With the Air4Gp powered-up connect the PC to the Ethernet port. 3. Configure the PC with an IP address in the 192.168.0.xxx range (e.g. 192.168.0.80 subnet 255.255.255.0). 4. In a browser, open web page with address 192.168.0.1 (Air4Gp default IP address). 5. Enter the default username and password: Username = air4gweb Password = thhr49Key 9.1.1 General Config Figure 27 – General BS Configuration Initial a. “BSΝIDΝSectorΝ1”ΝisΝmandatoryΝforΝsingleΝsectorΝorΝdualΝsector. b. InΝdualΝsector:Ν“BSΝIDΝSectorΝ1”ΝisΝtheΝinternalΝantenna,Ν“BSΝIDΝSectorΝ2”ΝisΝtheΝ external antenna. 6. Enter the BS ID Page 41 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Note: The format of the BS ID is important: NN-NN-NN-nn-nn-nn (where NNNN-NN is the Operator ID and nn-nn-nn is a unique address ID). 7. Select the BS Action from the available list. 8. Leave NTP Server as is (blank). 9. Click Submit. (Read Current = ignore/no action) (Clear IIB = ignore/no action) 9.1.2 NMS Config 1. Click NMS Config, as displayed below: Figure 28 - SNMP Initial Configuration 2. Define Read Only Community - SNMP read only community name defined by the BS network provider 3. Define Read Write Community - SNMP read/write community name defined by the BS network provider. 4. Leave Transport Type as is. 5. Leave BS Mgmt SNMP IP as is. 6. Leave the BS Mgmt SNMP Port number as is. Default = 161 7. Define the SNMP Trap Dest IP Addr. (IP address of Netspan) 8. Set the SNMP Trap Port Number (for communications with Netspan) to 162. 9. Click Submit. (Read Current = ignore/no action) (Clear IIB = ignore/no action) 9.1.3 Mgmt IP Config 1. Click Mgmt IP Config, as displayed below: Page 42 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 29 - Management IP Configuration 2. Define the IP address. 3. Define the Subnet Mask. 4. Define the Default GW MAC Address. Caution: Define Default GW only if required for Network Security. Consult with Provider. 5. Set the Management VLAN set to Untagged. Set to Tagged when with VLAN Tag ID. Consult with Provider. 6. Define the VLAN Tag ID – only when Management VLAN is set to Tagged. Consult with Provider. 7. Click Submit. (Read Current = ignore/no action) Caution: After Submit changes are applied immediately to the BS. Therefore the PC must now be re-configured to the new configuration (IP address and Subnet mask) to re-establish communication. 1. Return to General Config and in the BS Action. 2. Select Reset BS from the dropdown list. 3. Click Submit to perform a reset of the BS. 9.1.4 BS Operational State Note: Leave settings on BS Operational State as is. No configuration is required. Page 43 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide Figure 30 - Operational State Page 44 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide 10 Appendix A – Glossary of Terms AAA Authentication, Authorization and Accounting AAS Advanced Antenna System AF Application Function ARQ Automatic Repeat reQuest ASN Access Service Network ASN GW ASN Gateway ATCA Advanced Telecommunications Computing Architecture BS Base Station BWA Broadband Wireless Access CHAP Challenge Handshake Authentication Protocol CPE Customer Premises Equipment CQI Channel Quality Indicator CSN Connectivity Service Network DSM Digital Surface Model DTM Digital Terrain Model EAP Extensible Authentication Protocol FA Foreign Agent FBSS Fast Base Station Switching GUI Graphical User Interface HA Home Agent H-ARQ Hybrid Automatic Repeat reQuest HO Handover/Handoff IMS IP Multimedia Subsystem IP Internet Protocol IPsec IP security LR Location Register MAC Media Access Control MDH Macro Diversity Handover MIMO Multiple Input Multiple Output MIP Mobile IP MRC Maximal Ratio Combining MS Mobile Station NAP Network Access Provider NAS Network Access Server NLOS Non Line of Sight NSP Network Service Provider NWG Network Working Group Page 45 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide OBSAI Open Base Station Standard Initiative OFDMA Orthogonal Frequency Division Multiplexing (Multiple Access) PA Paging Agent PAAA Proxy AAA PC Paging Controller PF Policy Function PHY PHYsical Layer PMIP Proxy MIP PPP Point-to-Point Protocol RADIUS Remote Authentication Dial In User Service RRA Radio Resource Agent RRC Radio Resource Controller RRM Radio Resource Management SAS Smart Antenna System SDR Software Defined Radio SFA Service Flow Authorization SFM Service Flow Management SIM Subscriber Identity Module SIP Session Initiation Protocol SOFDMA Scalable Orthogonal Frequency Division Multiplexing (Multiple Access) STC Space Time Coding TDD Time Division Duplex VoIP Voice over IP X.509 ITU-T standard for PKI digital certificates Page 46 Commercial in Confidence UGD-D00236 Rev B Air4Gp Installation Guide 11 Appendix B 11.1 Revision History Revision Originator Date Description Rev A M. Falik 06-2012 Initial document Rev A1 M. Falik 07-2012 Power correction Rev B M. Falik 09-2012 Antenna, TX power & GPS kit, DC PoE 11.2 Contact Information 31B Customer Service Help-Desk for customer service emergency Airspan Networks have introduced the Airspan Tracker application to enable prompt and efficient Customer Support services. If you do not have an Airspan Tracker account, please obtain login credentials by filling-in the form in the main page www.airspan.com/Support Register New Account 93H Worldwide Headquarters: Airspan Networks Inc. 777, Yamato Road, Suite 310, Boca Raton, FL 33431, USA Tel: +1 561 893 8670 www.airspan.com Feedback: To provide feedback on this document, please send comments to the following email address: documentfeedback@airspan.com 94H Page 47 Commercial in Confidence UGD-D00236 Rev B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract Author : Meyer Falik Create Date : 2012:09:27 11:03:41+02:00 Keywords : FCC, -, ZL, version Modify Date : 2012:10:02 14:19:58+02:00 Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Meyer Falik Title : Air4G Installation Guide Subject : FCC - ZL version Creator Tool : Microsoft® Word 2010 Metadata Date : 2012:10:02 14:19:58+02:00 Producer : Microsoft® Word 2010 Document ID : uuid:11be0784-414a-4ea9-a5a9-c258f0caa8f6 Instance ID : uuid:8d5eb384-01ab-44bf-86ca-ade6725e88e5 Page Count : 47EXIF Metadata provided by EXIF.tools