3.4.3.3 – Connections to 120 ohm distributors – Connections to 120 ohm (E1) or 100 ohm (T1) distributor of the TNT connectors (J105 to J112) of the top panel of the DBS subrack with (n) 3CC11238AAxx cable(s). E1/T1 TNT1 1 – 89 9/16 1/8 E1/T1 TNT3 E1/T1 TNT4 – 16 TX E1/T1 TNT2 RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX Out put DBS C RX access In put DBS C TX access Figure 99 – Connection panel beneath the roof of the standard rack CLIENT ACCESS TY–RAP TO DBS Figure 100 – Cable mounting and grounding 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 121/346 128 Figure 101 – RJ45 Connector pin and signal assignment Figure 102 – Patch panel T1 (RJ45) Figure 103 – Repartiteur RJ45 1.10 m Figure 104 – Cable length ACC 11687 Axxx 122/346 128 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 3.4.4 – Client access connections (ATM network interface) 3.4.4.1 – Optical interface 155 Mbit/s ANT 1 ANT 2 OUT OUT IN IN CPL IN OUT Figure 105 – Fiber optic cables connection – use the fiber optic connection cables on the ANT and CPL board front panel. – To avoid damaging the fiber optic cables: • insert the jumpers in the direction indicated in Figure 106 – Fiber optic cables wiring, • connect the fiber optic connection cable, fitted with its SC/PC connector, to the optical coupler board by passing it through the top of the rack and along the cable run provided. – Use a winding cassette when connecting one or more fiber optic cables of over 10 meters in length. 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 123/346 128 Stages 1. According to the site configuration, prepare the connection cables and fit them with the required connectors. Figure 106 – Fiber optic cables wiring 2. Connect the fiber optic jumpers (see Figure 105 – Fiber optic cables connection and Figure 106 – Fiber optic cables wiring) and the main cables. DO NOT SET THE FIBER OPTIC IN FRONT OF THE VENTILATION PLUG-IN UNIT: SET IT AS SHOWN IN FIGURE 113 124/346 128 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 3.4.4.2 – Interface 34 Mbit/s Input 34 Mbit/s Output 34 Mbit/s Figure 107 – 34 Mbit/s cables connection 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 125/346 128 3.4.5 – Place of the board into the rack Slots Type of the elements Configuration main (1+0) ANT board ANT board TNT boards AMD boards 15 FAN 16 CPL board IBS-TLX boards 25 Supply assembly PSU 1 26 Supply assembly PSU 2 10 11 12 13 14 17 18 19 20 21 22 23 24 126/346 128 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 1 14 8 9 10 11 12 13 2 3 4 5 6 7 15 Vent IBS 7 IBS 4 IBS 5 IBS 6 IBS 3 IBS 2 21 22 23 CPL 20 IBS 1 19 16 17 18 PSU 1 IBS 8 ANT 1 ANT 2 TNT 1 TNT 2 TNT 3 TNT 4 AMD 1 AMD 2 AMD 3 AMD 4 AMD 5 AMD 6 AMD 7 AMD 8 ID number Slot number 24 PSU 2 25 26 Figure 108 – Place of the boards into the DBS 3.4.6 – End of the installation Replace the (removable) top cover of the rack and secure it. 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 127/346 128 PAGE INTENTIONALLY LEFT BLANK 128/346 128 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 4 – 7390LT software overview 4.1 – General information The purpose of this chapter is to present the different screens of the 7390LT software supplied with the Base Station. The following chapters will make reference to this presentation each time the user needs to access the software for a particular action (commissioning, maintenance or evolution of the configuration). The same screen may apply for several types of action. 4.1.1 – Functionalities The 7390 LT software enables: – supervision of both the system assembly as a whole (the NE (Network Element)), and of its subassemblies (BS, NT); – configuration of the sub-assemblies (DBS, X-Pol RBS, etc.) (used when Commissioning, Chapter 5 – Commissioning the Base Station (7390BS)); – setting up services (E1 leased lines, T1 and X21, ISDN, IP cross-connection including VoIP, circuit emulation), (used when Commissioning, Chapter 6 – Operation and maintenance); – downloading, NE configuration back-up and restoration (used in Maintenance, Chapter 6 – Operation and maintenance); – display of the system redundancy state; – management of external points; – radio performances. Note: the 7390LT software exchanges no information with the radio part of the terminal station (7390RT). These generate no alarms, and therefore require no other configuration apart from the installation configuration. 4.1.2 – Principles of the Man-Machine Interface (MMI) of the 7390LT The user of the 7390LT software is expected to be familiar with the operation of software in the Windows NTMT environment. There follows a description of some of the basic principles of the Windows NTMT MMI along with others, more specific to the 7390LT. 4.1.2.1 – Opening, closing and resizing a window Here is a reminder of how the boxes at the top right of an active window are used: Click on... To...... ...minimize the active window to place the application on the taskbar. Click on the taskbar icon to restore the window. ...maximize the window to full-screen size. ...restore a window which was in full-screen size to its original size. ...close the active window. 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 129/346 234 4.1.2.2 – Entry fields The grayed out fields are for consultation only: their content cannot be modified. The fields on a white background can be modified: left-click to make the cursor appear inside the field, then enter the character string required. According to the same principle, the buttons, icons and items in the pull-down menus become grayed out when they are inactive. 4.1.2.3 – Confirmation, closing a window, canceling an entry In the lower part of the windows there may be buttons (which may or may not be active; cf. § 4.1.2.2 – Entry fields), the principle of which is as follows: Click on... To...... ...confirm the data entry, while keeping the window open. ...close the active window, thereby cancelling any unconfirmed data entries. ...cancel the data entry, while keeping the window open. 4.1.2.4 – Sorting and searching in a list Some screens contain lists which may contain many lines; a sort and/or search tool is therefore available via the MMI, in order to facilitate data management: 4.1.2.5 – Selecting lines on a list To select a line, click on it and it is highlighted in blue. To select quickly a zone, click on the first line then select and hold down the 'Shift' key, then click on the last line of the desired zone. The zone becomes highlighted in blue. To select several non consecutive lines, hold down the 'Ctrl' key then select line by line the desired elements. 130/346 234 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 4.1.2.6 – Title, menu, button and status message bars The various information and functionalities of the 7390LT are accessible in several forms of MMI: Title bars (at the top of the main window): for information only; this is the title of the window. Menu bar (below the title bar): each menu contains items. To access, open the pull-down menu by left-clicking on the title, then click on the desired item (for execution it must be active, cf. § 4.1.2.2 – Entry fields). Button bar (below the title bar): certain menu functionalities are also directly accessible by clicking on the buttons displayed at the top of the window. Message bar (at the bottom of the active window): messages linked to current events are displayed on the fly in certain windows Status bar (at the bottom of the 7390 LT main window), divided into 2 areas: – on the left: global user's messages (states of progress, error messages, etc.) – on the right: Local access: information about write access: cf. § 4.4.2 – Local access requests – Number of NTs: displays the number of NTs declared in the NE. – Most critical alarm: displays the color of the most critical alarm (see alarm color codes, § 4.10.1.2 – Alarms color code). 4.1.2.7 – Dynamic keys Each time the cursor will stay a few seconds on a button (and on specific field), a textual key on a yellow background defining this button (or field) is displayed. 4.1.3 – Rearrangement of active windows During the use of the 7390 LT software, several windows may be active simultaneously. The MMI allows you to rearrange them to optimize their visibility, in classic Windows fashion. Access this function by opening the Windows pull-down menu: 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 131/346 234 4.1.4 – Printing To print all the elements of the list To print all the elements selected in the list To print the elements non selected in the Color printing Black and white printing Direction of the page: landscape (horizontal) Direction of the page: portrait (vertical) Note: to know how to select lines in lists, see § 4.1.2.5 – Selecting lines on a list. 132/346 234 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 4.2 – Running and quitting the software 4.2.1 – Installation of the 7390 LT software The 7390 LT is either loaded on the PC which came with the BS, or comes on an installation medium (e.g., CD-ROM). If you need to install the 7390 LT software, refer to the Appendix 2 – Installation of 7390LT software; otherwise, go directly to the next paragraph to run the already installed software. ON THE ETHERNET PORT IT IS RECOMMENDED TO CONFIGURE ONLY ONE IP ADDRESS 4.2.2 – Accessing and running 7390 LT To run 7390 LT, go to the Windowsâ taskbar and left-click on the Start button: the Start menu is displayed. Next, select the Programs menu followed by the line Craft_Terminal. or: Click on the icon shown here which is on the Windows desktop. To run the 7390 LT, the following screen is displayed: 7390LT software version. Version of the «Info Model» common exchhange database at the Manager (7390LT) side Version of the «Info Model» common exchange database at the Agent (NE) side, filled in automatically upon connection to the NE Short-cut to the Microsoftw system management function (refer to corresponding documentation) Click here to close the About window and work on the main window of the 7390 LT. You can access it again by selecting the heading About 7390 LT (Craft_Terminal) in the ? menu. Note: After NE connexion (cf. § 4.3.1 – NE Connection), the database versions at the Manager and Agent sides must be identical. If the LT session cannot open, check if there is any other LT open session. 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 133/346 234 On the screen displayed, only one icon is active: the choice of language and the NE connection icon: ...click on the icon to access the NE connection (cf. comments in § 4.3.1 – NE Connection) 4.2.3 – Quitting the 7390 LT To quit the 7390LT, open the Management pull-down menu and click on Quit A confirmation dialog box is displayed: Click here to confirm quitting the 7390LT Click here to cancel the request to quit the 7390LT and return to the previous window This operation includes the NE disconnection (cf. § 4.3.2 – Disconnecting the NE assembly). 134/346 234 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 4.3 – Connection and Disconnection 4.3.1 – NE Connection The NE connection process consists partly in the NE "Agent" identifying the "Manager" and partly in the retrieval of data for the NE assembly on the 7390 LT software by manual request: this involves the updating of site information. ONLY ONE LT SESSION IS OPERATIONAL ON ONE NE. FOR EXAMPLE, A LOCAL LT CONNECTION AND A REMOTE LT CONNECTION AT THE SAME TIME ON THE SAME BS IS NOT POSSIBLE There are two possible ways of accessing the NE Connection: – click on the first button (provided that it is active; cf. § 4.1.2.2 – Entry fields) of the main menu button bar, or else, – open the Management pull-down menu and select the first item: NE Connection. The following screen is displayed: IP Address of the NE to be connected: click in a byte field to modify the value (local IP default address value must be: 192.168.99.1). Connection type: with data upload (default selection) Subject of supervision: NE system or BS Network Type: there are two types of network: local (LAN) or remote (WAN): check the button for the type of network corresponding to the system configuration Click here to run the data update procedure Click here to return to the previous screen In case several interface boards are installed in the PC, the window offers you a choice of board. 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 135/346 234 By default, the update is done via FTP. The next screens will be displayed: Note: In order to start the FTP process, there must not be any other FTP service or application running in the PC. Windows NT includes a FTP service that is, by default, desactivated; if it were activated, the operator must stop it from the Services window through the Control Panel. If there were any problem with the FTP process, the craft.ini file must be opened. Change the UploadThruFTP value, it must be: UploadThruFTP=No. Throughout the update, an animated display indicates to the user that data transmission is underway, with on-screen indication of the progress of the processed files. In this case, the next screen would be displayed: 136/346 234 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 Note: While updating, if the database versions at the Manager and Agent sides are not identical, the animation stops and an error message is displayed to notify it. (cf. corrective actions in appendix A.6.1 – Error messages for 9900LT software). Once the update is completed, two new windows are displayed: – one screen providing a global view of the base station (cf. § 4.5 – Base Station Supervision); – and one screen summarising the current alarms (cf. § 4.10.1 – Alarms). 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 137/346 234 4.3.2 – Disconnecting the NE assembly The NE disconnection process consists in closing the current session relating to a given NE in order to connect to another NE of the system. To access the NE disconnection function, open the Management pull-down menu then select the item: Disconnect NE. A confirmation screen is displayed: Click here to confirm the disconnection 138/346 234 Click here to cancel the request to disconnect and return to the previous window Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01 4.4 – Supervision Principles The 7390 LT can be used for supervising the whole A7390 Network Element (NE) system. The NE comprises of: – a Base Station (7390BS) which mainly includes a Radio unit (X-Pol RBS) and a MODEM rack (DBS), – one or more Terminal Stations (7390TS) which mainly include a Radio unit (X-Pol RT) and a User connection unit (NT). Nevertheless the 7390 LT software does not manage X-Pol RT units. The display allows system control; alarms are activated in particular to signify any intervention. The supervision items themselves are, by definition, grayed out and therefore unmodifiable, whereas those reserved for configuration can be configured by the user: they will be used in the following chapters concerning commissioning (Chapter 5 – Commissioning the Base Station (7390BS)), maintenance (Chapter 6 – Operation and maintenance) and configuration evolution (Chapter 7 – Changes of configuration). For the modifications to be taken into account, writing should be enabled: see § 4.4.2 – Local access requests. 4.4.1 – Data retrieval According to the same principle as for starting up the 7390 LT (automatic data retrieval following connection), this update can be carried either for whole NE, or for each equipment: BS or NT. To reach the Data retrieval function, two ways are possible: – open the Database pull-down menu and choose the first item: NE MIB Upload, – or click on one of the button in the screen of the equipment in question: Click on...... To...... ...activate the data recovery function for the NE, BS, and NT respectively. Note: These operations may take quite a long time (in particular for the NE) since they depend on the connection between NE and manager and on the round trip delay and the NE composition. 4.4.2 – Local access requests The general status bar (cf. § 4.1.2.6 – Title, menu, button and status message bars) displays in its central part the messages concerning write access rights on the NT configuration: "Local Access : Denied / granted". Where there are different system managers, these access rights are allocated by the OS manager, write access is authorized for the 7390 LT (local access set to granted) when no OS manager is connected to the NE (local access set to granted) when no OS manager is connected to the NE. 4.4.3 – Administrative statuses Locking the administrative status of sub-assemblies allows the maintenance operator to disable the sub-assembly manifesting an anomaly without disturbing the system. Unlocking sub-assembly administrative status frees service use for the end user. Operator is not able to modify the administrative state assembly. He can only change the ports and cross-connections. 3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 139/346 234 4.5 – Base Station Supervision When the LT is started up for the first time, the Manager has to define the type of polarization used, in this «Cross-polarization» type must be selected Click to choose Cross-Polarization type AFTER CLICKING ON THE «APPLY» BUTTON, A WARNING WINDOW WILL APPEAR SINCE THIS PROGRESS IS IRREVERSIBLE, EXCEPT THROUGH AN ANT RAM-REINITIALIZATION. ONCE ACCEPTED, THE 7390LT STARTS TO RECEIVE EVENTS FROM THE SYSTEM Synchronization parameters: cf.§.4.5.4 – BS Supervision: cf.§ 4.5.1 – Inhibit BS Alarms: cf.§ 4.5.1 Radio parameters: cf.4.7.1 BS UpLoad: cf.§ 4.4.1 Local IP addresses parameters: cf.§ 4.9.2 Configuration of the Network addresses: cf.§.4.9.3 – ATM parameters: cf.§.4.9.1 Consultation of the redundancy state: cf.§.4.5.8 – IP Data traffic configuration: cf.§ 1. On demand service management: cf.§ 4.7.3 –§ Bandwidth allocation: cf.§ 4.7.4 – List of external points: cf.§ 4.10.3 – NE time setting: cf.§ 4.5.5 Memory initialization: cf.§ 4.5.6 – Actions of the BS boards: cf.§ 4.5.3 – X-Pol RBS display: cf.§. DBS display: cf.§ 4.5.3 Become accessible when ’’Name’’ or ’’Location’’ fields are modified 140/346 234 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2001:08:21 11:14:42-03:00 Create Date : 2001:08:21 11:14:25-03:00 Title : 3cc12426aaaaTQbja01.book Creator : FrameMaker 6.0 Producer : Acrobat Distiller 4.0 for Windows Page Count : 20 Mod Date : 2001:08:21 11:14:42-03:00 Creation Date : 2001:08:21 11:14:25-03:00 Metadata Date : 2001:08:21 11:14:42-03:00EXIF Metadata provided by EXIF.tools