Alcatel Canada 39T28A03A22A Alcatel 7390 LMDS Multiservice Broadband Wireless User Manual 3cc12426aaaaTQbja01

Alcatel Canada Inc Alcatel 7390 LMDS Multiservice Broadband Wireless 3cc12426aaaaTQbja01

Base Sation User Manual 14 of 14

Download: Alcatel Canada 39T28A03A22A Alcatel 7390 LMDS Multiservice Broadband Wireless User Manual 3cc12426aaaaTQbja01
Mirror Download [FCC.gov]Alcatel Canada 39T28A03A22A Alcatel 7390 LMDS Multiservice Broadband Wireless User Manual 3cc12426aaaaTQbja01
Document ID175952
Application IDmTthSkDkyAzEow6jbf2b4A==
Document DescriptionBase Sation User Manual 14 of 14
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize250.57kB (3132119 bits)
Date Submitted2001-10-24 00:00:00
Date Available2001-12-11 00:00:00
Creation Date2001-08-21 11:29:05
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2001-08-21 11:29:24
Document Title3cc12426aaaaTQbja01.book
Document CreatorFrameMaker 6.0

– Press "Finish".
– Now you are ready to use Python for the MIB migration.
A.3.4 – LT configuration file modification
If the MIB migration CD content has not been copied in the default directory ("C:"), you need to edit the
LT configuration file (C:\ProgramFiles\7390LT\Craft.ini) and modify the following parameter:
MIB_MIGRATION_SCRIPT_PATH="C:\mibconv"
If "Python" has not been installed in the default directory, you need to edit the LT configuration file
(C:\ProgramFiles\7390LT\Craft.ini) and modify the following parameter:
MIB_MIGRATION_PYTHON_EXE="C:\Program Files\Python\Python.exe"
3CC12426AAAA TQ BJA 01
Issue 01 - April 2001 - Draft 04
331/346
332
PAGE INTENTIONALLY LEFT BLANK
332/346
332
Issue 01 - April 2001 - Draft 04
3CC12426AAAA TQ BJA 01
Appendix 4 – Mounting coaxial connector
Mounting on cable LDF4
Alcatel Code: 77096434
3CC12426AAAA TQ BJA 01
Issue 01 - April 2001 - Draft 04
333/346
336
334/346
336
Issue 01 - April 2001 - Draft 04
3CC12426AAAA TQ BJA 01
3CC12426AAAA TQ BJA 01
Issue 01 - April 2001 - Draft 04
335/346
336
PAGE INTENTIONALLY LEFT BLANK
336/346
336
Issue 01 - April 2001 - Draft 04
3CC12426AAAA TQ BJA 01
Appendix 5 – Correspondence between commercial
codes and industrial codes relating to the BS
Installation item
Commercial code
Industrial code
Comments
DBS basic configuration
Rack 22 U
9900CAB001
3CC 10067 AAxx
DBS installation items
Power S. cable
Distributor Panel
16x2 Mbits/s
POWCAB0001
77096649
15 m 3x10 mm2
9900XXI416
3CC 08061 AAxx
2x3CC 11236 AAxx
75 Ohms
1.6 / 5.6
9900XXI416
3CC 08061 ABxx
2x3CC 11237 AAxx
75 Ohms / BNC
9900XXI416
3CC 10316 ABxx
2x3CC 11238 AAxx
120 Ohms - EMC
RBS installation items
Grounding cable
(20 meters)
9900XXC502
3CC 08166 AAxx
(per meter)
Consummable
9900UXT002
3CC 06503 AAxx
50 Ohms coaxial cable
(50 meters)
9900UXI202
50 m of
1AC 001100022
Coaxial connector
9900UXI203
2 x 1AB 095530021
Grounding kit
9900UXI204
1AB 128500002
114 mm tube (2 meters)
SUPOUTD001
3CC 04658 AExx
2 pole-mounting fastening kit
(1+1)
9900UXI104
3CC 11681 AAxx
Self supporting mast 114 mm
(1.5 meter)
SUPMAST001
3CC 05148 AAxx
Cable tray cablofil (6 m)
INFRA00003
3CC 07580 AAxx
Cable tray PVC (4 m)
INFRA00004
3CC 06511 AAxx
Cable tray CES (12 m)
INFRA00005
3CC 06759 AAxx
Gaine Capri (12 m)
INFRA00006
3CC 06512 AAxx
Cable LDF 4-50
9900WVG001
77 096 434
50 Ohms (10 m)
N Connector kit
9900UXX022
77 096 433
N male right,
1 for each cable
LDF4-50
3CC12426AAAA TQ BJA 01
Issue 01 - April 2001 - Draft 04
(x2)
337/346
338
Installation item
Commercial code
Industrial code
Comments
Jumper
9900WVG004
3CC 09514 AAAA
N male bented/
Nmale right (3 m)
Jumper
9900WVG005
3CC 09514 ABAA
N female bented/
N male right (3 m)
RBS installation tools
Tool kit
9900UXT103
3CC 08409 AAxx
PC 9900LT
Laptop PC French
(incl. Ethernet module)
9900LTH001
3CC 10939 AAxx
Desktop PC French
(incl. Ethernet module)
9900LTH002
3CC 10626 AAxx
Laptop PC English
(incl. Ethernet module)
9900LTH001
3CC 11200 AAxx
Desktop PC English
(incl. Ethernet module)
9900LTH002
3CC 11201 AAxx
NFS Server software
LT application software
CDROM
Embedded software
package CDROM
CDROM User Manual
2.1, 2.2a, 2.2b
338/346
338
1AH 00845 AAxx
3CC 12468 AAxx
9900LTS001
3CC 12464 AAxx
3CC 12144 AAxx
Issue 01 - April 2001 - Draft 04
3CC12426AAAA TQ BJA 01
Appendix 6 – Error messages and corrective actions
The tables below list the main error messages when operating 7390 LT.
The purpose of this chapter is to give, for each message, an additional information and to suggest one
or more corrective actions. However, various causes may originate malfunction and it may occur and
derive one from another; thus the corrective action suggested may not be the only solution. Furthermore,
the operator is, in some cases, free to take initiative to solve the problem, considering that
troubleshooting should take into account the configuration context.
Whenever the malfunction is not fixed, please contact TAC (see page 3).
A.6.1 – Error messages for 7390LT software
Message
Definition
Corrective actions
Error in craft.ini file
7390LT software can not be launched, its configuration file contains
errors. The errored parameter name
is displayed on the screen.
The solution requires an
intervention at the craft.ini file
level. Only qualified personnel
should intervene.
For this purpose, please contact
the TAC (see page 3).
An error occured when
opening the Data Base
7390LT can not retrieve its data
base files.
Make sure the .mdb files are installed in the database directory. If
not, install again 7390LT (see
Appendix A.2).
Info model version compatible
When connecting to a BS, the data
base versions differ on agent and
manager side: e.g.: the 7390LT is
version 2.1 whereas the base station is version 2.0.
Perform download of the appropriate software version (see §
7.3.10).
A.6.2 – NT management error messages
Message
Definition
Corrective actions
Error when declaring the
new NT
Declaring the new NT is denied.
Make sure that:
. the serial number is valid,
(preceded by 4 dashes then CU
follow-up by 1 dashe)
. the associated AMD board
configuration is fully carried out.
An NT with this index
already exists
The NT identification number entered is already assigned to another
NT.
Assign a free number. Contact
the scheduler.
Waiting NT characteristics
This message displays a system
status and shows no anomaly. At
the end of the NT creation, the system is waiting for information about
it.
Please, wait until the relevant
information is transmitted.
Error at the reception of
SNMP message: Error
when destroying the NT.
The NT destroy control is denied,
one of its ports being used by an IP
cross-connection or leased lines
(LL).
Delete all IP or LL cross-connections that use the NT ports
before initiating the NT destroy
control.
3CC12426AAAA TQ BJA 01
Issue 01 - April 2001 - Draft 04
339/346
344
A.6.3 – Error messages for communication between BS and 7390LT
Message
Definition
Corrective actions
An error occured at the
BS connection: Error
when declaring the
manager
Declaring the manager is denied.
Make sure that no other LT
session is active (see section
4.3.1).
Connection failure: NE
not found
The communication establishment
with BS at the IP level failed.
. Check the IP level link with BS.
. Check if the cable fits to your
network configuration (crossed or
no Pc-DBS ethernet cable).
TIMEOUT on request
No answer to SNMP request when
timeout expired. One of the causes
may be a communication
interruption between the BS and the
PC on which 7390 LT is installed.
This interruption may be brief. If this
problem is persistent, the message
"The connection with the NE has
been lost. The Craft will be reinitialized" comes to confirm a
permanent cut.
If the interruption is brief, the
malfunction will disappear
without any intervention being
required. In case of a permanent
cut, refer to the following message: "The connection with the
NE has been lost. The Craft will
be re-initialized".
The connection with the
NE has been lost. The
Craft will be re-initialized
Permanent cut of communication
between the BS and the PC on
which 7390LT is installed.
Start again the 7390LT. If the
problem persists, check all elements involved in the connection
between BS and PC.
A.6.4 – Error message linked with client services
A.6.4.1 – Error messages linked with E1 leased lines
Message
Definition
Corrective actions
Already involved in another cross-connection
Creation control for a leased line
denied, assigned TSs being already
used by other cross-connections.
Try to create another leased line
using available TSs.
A cross-connection
exists on the TNT port
N°xxx
Creation control for a leased line
denied, another line using the port
N°xxx of the TNT.
Try to create another leased line
using available TNT port (see the
cross-connections list in section
4.11.4.1).
A cross-connection
exists on the NT port
N°xxx
Creation control for a leased line
denied, another line using the port
N°xxx of the NT.
Try to create another leased line
using available NT port (see the
cross-connections list in section
4.11.4.1).
Error when creating the
cross-connection: not
enough downstream
resources allocated.
Creation control for a leased line
denied because of a lack of resources for the upstream communication.
Check the upstream channel
traffic using the supervision (see
section 4.7).
Error when creating the
cross-connection: not
enough upstream resources allocated.
Creation control for a leased line
denied because of a lack of resources for the downstream communication.
Check the allocation with the
scheduler.
340/346
344
Issue 01 - April 2001 - Draft 04
3CC12426AAAA TQ BJA 01
Message
Definition
Corrective actions
The selected ports must
be configured identically
before selecting a TS
(Time Slot).
Creation control for a leased line
denied because the selected ports
have a different configuration.
Check the configuration of the NT
and TNT ports (see section
4.11.1.3). Perform any relevant
modification.
E1 slots must be consecutive
Creation control for a leased line
denied because the time slots numbers are not consecutive.
Assign contiguous numbers to
time slots (TS).
Time out on creating the
leased line
Creating the leased line did not succeed at the time out.
Carry out data downloading (see
section 4.4.1).
Time out on deleting the
selected leased line
Deleting the selected leased line did
not succeed at the time out.
Carry out data downloading (see
section 4.4.1).
Error when deleting the
Cross-connection: the
cross-connection on
leased line is not locked
Creation control for a cross-connection on leased line denied because
it is liable to route traffic.
Lock the cross-connection before
triggering the deletion control
(see § 4.11.4.5).
A.6.4.2 – Error messages linked with IP "cross-connection"
Message
Definition
Corrective actions
Error when creating the
Cross-connection:
Down Resource Problem.
Creation control for an IP cross-connection denied because of a lack of
upstream resources.
Check upstream traffic using the
supervision (see section 4.7).
Error when creating the
Cross-connection:
Up Resource Problem.
Creation control for an IP cross-connection denied because of a lack of
down-stream resources.
Check allocation with the
scheduler.
Error when creating the
Cross-connection: Ethernet Port already involved.
Creation control for an IP cross-connection denied because the NT
Ethernet port is already used.
see the IP cross-connection list
that displays the used ports (see
section 4.12.2.1). Carry out any
relevant modification.
Error when creating the
Cross-connection:
ATM Port Value error.
Creation control for an IP cross-connection denied because one of the
following values is false: either
"VCL Vpi" or "VCL Vci".
Assign a value within the range of
the possible values (see section
4.12.2.3).
Error creating the crossco : ATM Medium type is
not configured
Configure the ATM medium type
(see section 4.9.1).
A.6.4.3 – Error messages linked with circuit emulation
Message
CES link configuration
failed
3CC12426AAAA TQ BJA 01
Definition
Creation control for an CES denied
because the TNT port is unlocked.
Issue 01 - April 2001 - Draft 04
Corrective actions
lock TNT port (see section
4.11.1.4)
341/346
344
A.6.5 – Download error messages
Message
Definition
Corrective actions
Software download done
with problems detected.
An error occurred during data download.
. Check the NFS server status is
operational,
. Chek hardware description for
the BS boards.
. Check the exported directory
has been added to the omni-NFS
server during a session with
adminis-trator rights.
Package commit done
with problems.
An error occurred during referencing.
Check for any current board
alarms. If so, rectify the problem
in all cases (whether or not the
card presented an alarm) carry
out again a complete download.
A.6.6 – Error message at backup / restore
Message
Error when transfering
the sRam File
Definition
NFS server problem (directory not
recognized by the server)
Corrective actions
Export the directory in R/W to the
NFS server.
A.6.7 – Error messages for radio management
A.6.7.1 – Error messages linked to the radio configuration
Message
Error when setting the
radiolink characteristics
Definition
Corrective actions
The modification of the radio link
characteristics displayed cannot be
taken into account.
Before modifying the bandwidth,
suppress the NTs linked to this
radio link (see 4.6.3)
A.6.7.2 – Radio Resources Manager (RRM)
Message
Definition
Corrective actions
Bad static Value downstream
Inconsistency between the services
already created and the modified
static zone in the downstream
- Cancel the modification
- Update the static zone with a
value compatible with the static
services already created
Bad static Value upstream
Inconsistency between the services
already created and the modified
static zone in the upstream (x from
1 to 4)
- Cancel the modification
- Update the static zone with a
value compatible with the static
services already created
Bad dynamic max Value
downstream
Inconsistency between the services
already created and the modified
dynamic zone in the downstream.
Update the dynamic zone with a
value compatible with the
dynamic service already created
and the overbooking factor limit
342/346
344
Issue 01 - April 2001 - Draft 04
3CC12426AAAA TQ BJA 01
Message
Definition
Corrective actions
Bad dynamic Value upstream x
Inconsistency between the services
already created and the modified
dynamic zone in the upstream.
Update the dynamic zone with a
value compatible with the
dynamic service already created
and the overbooking factor limit
Bad dynamic max Value
upstream x
(x from 1 to 4)
Update over booking factor limit
with a value compatible with the
dynamic services created and
the dynamic zone.
A.6.8 – ASAP error messages
Message
Error removing ASAP
Definition
Corrective actions
The ASAP cannot be removed
because at least one NT is attached
to the ASAP table.
Before removing, the ASAP table
has to be deleted for each NT
attached to the table.
A.6.9 – Miscellaneous error messages
Message
Definition
Corrective actions
Error when destroying
the board
Board deletion control denied.
The corrective action is related to
the type of board:
. AMD board: make sure that no
NT is associated with the board.
. TNT board: make sure that no
port is used either by a leased
line or as a potential source of
synchronization.
. NT board: make sure that no
port is used either by a leased
line or by an IP cross-connection.
Error when modifying the
TNT board
The modification of the TNT board
characteristics cannot be taken into
account.
All circuit emulation services
must be suppressed before
modifying the configuration of a
TNT board.
Error when updating the
BS
In BS's local network screen one
parameter is not correct.
- Check that BS's IP address is a
real IP address.
- Check that Ethernet and ATM
networks are different.
Error when setting synchro parameters
Synchronization configuration is not
allowed.
Check that the reserved channels are configured (see § 4.11).
Error when enabling/
disabling E1 traffic on a
TNT port
Enabling/disabling is not allowed.
If the TNT port is used for system
synchronization, the TNT port
cannot be locked.
3CC12426AAAA TQ BJA 01
Issue 01 - April 2001 - Draft 04
343/346
344
PAGE INTENTIONALLY LEFT BLANK
344/346
344
Issue 01 - April 2001 - Draft 04
3CC12426AAAA TQ BJA 01
Appendix 7 – List of abbreviations
MNEMONIC
ENGLISH
MNEMONIC
ENGLISH
AAL
ATM Adaptation Layer
I2C or IIC
Inter Integrated Circuit
AIS
Alarm Indication Signal
ID
IDentifier
AL
Alarm
IEC
AMD
ATM Modulator Demodulator
International Electrotechnical
Commission
ANT
ATM Network Termination
IM
Information Model
ASAP
Alarm Severity Assignment Profile
IP
Internet Protocol
ATM
Asynchronous Transfer Mode
ISDN
Integrated Services Digital Network
AT
Attend alarm on LT
ITU
International Telecommunication
Union
AVC
Attribute Value Change
LAIS
Line Alarm Indication Signal
BER
Bit Error Rate
LAN
Local Area Network
BNC
Bayonet-locking Connector
LED
Light Emitting Diode
BS
Base Station
LMDS
Local Multipoint Distribution Service
CBR
Constant Bite Rate
LMFA
Loss of MultiFrame Alignment
CCIR
International radio consultative
comitee
LOF
Loss Of Frame
LOP
Loss Of Pointer
CEPT
Conference of European Post and
Telecommunications administrations
LOPC
Loss Of Polling Cell
LORF
Loss Of Radio Frame
CPL
Coupler
LOS
Loss Of Signal
CRC
Cyclic Redundancy Check
LRDI
Line Remote Defect Indicator
DBS
Digital Base Station
LT
Local Terminal
EMC
ElectroMagnetic Compatibility
MAC
Medium Access Control
EPROM
Electronically Programmable
Read-Only Memory
Mbps
Mega Bit Per Second
ETSI
European Telecommunications
Standards Institute
MIB
Management Information Base
MMI
Man Machine Interface
ETH
Ethernet
MSC
Message Sequence Chart
FAS
Frame Alignment Signal
MUX
Multiplexer
NE
Network Element
NFS
Network File System
NIT
Network Installation Tool
NRZ
Non return to zero
NT
Network Terminal
FEC
Forward Error Correction
HDB3
High Density Binary 3 code
(3rd order)
IBS
Intermediate frequency Base Station
ICS
Identifier Change Status
3CC12426AAAA TQ BJA 01
Issue 01 - April 2001 - Draft 04
345/346
346
MNEMONIC
ENGLISH
MNEMONIC
ENGLISH
OC
Object Creation
VPI
Virtual Path Identifier
OD
Object Deletion
VCI
Virtual Channel Identifier
OOF
Out Of Frame
WAN
Wide Area Network
OS
Operation System
X-Pol RT
Cross Polarized Radio Terminal
PAIS
Path Alarm Indication Signal
X-Pol RBS Rx
PC
Personal Computer
Cross Polarized Radio Base Station Reception
PCR
Peak Cell Rate
X-Pol RBS Tx
Cross Polarized Radio Base Station Emission
PDH
Plesiochronous Digital Hierarchy
PLL
Phase Locked Loop
PSU
Power Supply Unit
PVC
Permanent Virtual Circuit
QAM
Quadrature amplitude Modulation
RAI
Remote Alarm Indicator
X-Pol RBS
Radio of Base Station
RDI
Remote Defect Indication
REI
Remote Error Indication
RF
Radio Frequency
RIT
Radio Installation Tool
RT
Radio Terminal
SC
State Change
SDH
Synchonous Digital Hierarchy
SMD
Surface Mounted Device
SNMP
Simple Network Management
Protocol
SNTP
Simple Network Time Protocol
STP
Shielded Twisted Pair
TAC
Technical Assistance Center
TCP
Transmission Control Protocol
TDM
Time Division Multiplex
TE
Transaction End
TNT
TDM Network Termination
TS
Terminal Station
UNI
User Network Interface
346/346
346
END OF DOCUMENT
Issue 01 - April 2001 - Draft 04
3CC12426AAAA TQ BJA 01

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2001:08:21 11:29:24-03:00
Create Date                     : 2001:08:21 11:29:05-03:00
Title                           : 3cc12426aaaaTQbja01.book
Creator                         : FrameMaker 6.0
Producer                        : Acrobat Distiller 4.0 for Windows
Page Count                      : 16
Mod Date                        : 2001:08:21 11:29:24-03:00
Creation Date                   : 2001:08:21 11:29:05-03:00
Metadata Date                   : 2001:08:21 11:29:24-03:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: F9R39T28A03A22A

Navigation menu