Andrew Wireless Innovations Group RPT-MOR701 PCS Repeater User Manual M0069A0A

Andrew Wireless Innovations Group PCS Repeater M0069A0A

User Manual

Download: Andrew Wireless Innovations Group RPT-MOR701 PCS Repeater User Manual M0069A0A
Mirror Download [FCC.gov]Andrew Wireless Innovations Group RPT-MOR701 PCS Repeater User Manual M0069A0A
Document ID88978
Application IDFPLpXX7W+ysAWbUL+oywOw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize201.38kB (2517243 bits)
Date Submitted2000-03-02 00:00:00
Date Available2000-03-02 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareAcrobat PDFWriter 3.02 für Windows
Document Lastmod1999-06-25 08:26:33
Document TitleM0069A0A.PDF
Document CreatorMicrosoft Word

User’s manual for Remote Unit MOR701B Power
User’s manual for
band or channel selective Remote Unit
MOR701B Power
(Id.-Nos.: 147362/148669)
Author:
M0069A0A.doc
Approved:
Id.-No 151154
QA:
Page 1
23-June-99
User’s manual for Remote Unit MOR701B Power
Table of Contents
LIST OF UNIT SPECIFIC ABBREVIATIONS
CONTENTS OF DELIVERY
HEALTH AND SAFETY WARNING
10
PREAMBLE
11
13
INTRODUCTION
1.1
Intended purpose
13
1.2
About the MOR701B POWER
13
FUNCTIONAL DESCRIPTION
14
2.1
General
15
2.2
RF modules
15
2.3
Mother board
17
2.4
Control module SM 2009
18
2.5
Duplexer
19
2.6
Active Combiner
20
2.7
Transceiver MFY1319
20
2.8
FSK modulator
21
2.9
4-way-Splitter
22
2.10
Measuring aids
22
2.11
Power supply
22
2.12
Feed forward amplifier
24
M0069A0A.doc
Id.-No 151154
Page 2
23-June-99
User’s manual for Remote Unit MOR701B Power
FUNCTIONS AND FEATURES
25
3.1
Band and channel selectivity
25
3.2
Gain setting
25
3.3
ALC
26
3.4
BITE and alarms
3.4.1
Handling of alarms
3.4.2
Status report
3.4.3
Severity levels
26
28
29
30
32
OPTIONAL EQUIPMENT
4.1
VSWR module
32
4.2
External alarms
32
4.3
Battery backup module
34
SPECIFICATION
36
5.1
Electrical specification
36
5.2
Optical specification
38
5.3
Mechanical specification
38
5.4
Environmental and safety
38
5.5
External electrical interfaces
5.5.1
Electrical power
5.5.2
RF connection
5.5.3
Optical connector
39
39
40
40
41
6.1
INSTALLATION
Mechanical installation
42
6.2
Electrical installation
6.2.1
Grounding
6.2.2
Power connection
6.2.3
Connection of the antenna cable
6.2.4
Connecting fibre optic cables
M0069A0A.doc
Id.-No 151154
45
45
46
46
47
Page 3
23-June-99
User’s manual for Remote Unit MOR701B Power
SETTING TO WORK
7.1
49
Preparation
49
7.2
Setting of operational parameters
7.2.1
Manual setting of the attenuation by means of rotary switches
7.2.2
Settings via personal computer as terminal
7.2.3
Remote control via Master Unit
50
50
52
54
TROUBLE SHOOTING
55
8.1
Error indication
55
1.2
Boot process
55
1.3
Alarm monitoring with the STATUS HIST command
56
1.4
Power supply
56
1.5
General remarks
56
MAINTENANCE
57
9.1
General
57
9.2
Replacement of the fuses (mains)
57
9.3
Replacement of the power supply fuse
58
9.4
Replacement of the mains cable
58
9.5
Replacement of the RAM / RTC battery
59
9.6
Replacement of the dummy battery backup module
60
9.7
Replacement of the duplexer
61
9.8
Replacement of RF modules
62
9.9
Replacement of the control module SM 2009
64
9.10
Replacement of power supplies
65
9.11
Replacement of Active Combiner modules
66
9.12
Replacement of feed forward amplifier
67
9.13
Replacement of the FSK modulator
69
M0069A0A.doc
Id.-No 151154
Page 4
23-June-99
User’s manual for Remote Unit MOR701B Power
9.14
Replacement of the Transceiver MFY1319
69
10
SPARE PARTS LIST
70
11
CONFIGURATION LIST
72
12
APPENDIX
73
12.1
Installation drawing of the Repeater
73
12.2
Top view of the Repeater (left-hand side , four channel configuration)
74
12.3
Top view of the Repeater (right-hand side, four channel configuration)
75
12.4
One channel configuration –block diagram and cabling
76
13
INDEX
M0069A0A.doc
78
Id.-No 151154
Page 5
23-June-99
User’s manual for Remote Unit MOR701B Power
LIST OF FIGURES AND TABLES
table 1-1 List of international sales offices............................................................................12
figure 2-1 Block diagram of MOR701B Power.....................................................................14
figure 2-2 Top view of an RF module...................................................................................16
figure 2-3 Top view of a mother board .................................................................................17
figure 2-4 Top view of the control module............................................................................18
figure 2-5 Top view of the duplexer......................................................................................19
figure 2-6 Top view of an Active Combiner module .............................................................20
figure 2-7 Transceiver MFY1319 .........................................................................................20
figure 2-8 Installation position of the Transceiver.................................................................21
figure 2-9 Configuration of the connecting pins....................................................................21
figure 2-10 Top view of the 4-way-Splitter (Transceiver dismounted) ..................................22
figure 2-11 Mounting position of power supplies..................................................................23
figure 2-12 ON / OFF position of external switch .................................................................24
figure 2-13 Top view of the feed forward amplifier ..............................................................24
figure 3-1 Position of rotary switches ...................................................................................25
figure 3-2 Position of failure LEDs.......................................................................................26
figure 3-3 Status hist report ..................................................................................................27
table 3-4 List of all available alarms .....................................................................................28
figure 3-5 Example of a GET1 report ...................................................................................29
figure 3-6 Example of a STATUS report ..............................................................................30
figure 4-1 Clamps for external alarms...................................................................................32
figure 4-2 Cable configuration and installation position........................................................34
figure 4-3 Mounting position of batteries..............................................................................35
figure 5-1 Screw terminal for mains cable ............................................................................39
figure 5-2 Connector panel layout ........................................................................................40
figure 6-1 System description ...............................................................................................41
figure 6-2 Wall mounting brackets .......................................................................................43
figure 6-3 Clearance distance................................................................................................44
figure 6-4 Grounding kit.......................................................................................................45
figure 6-5 Screw terminal .....................................................................................................46
table 7-1 LED indication ......................................................................................................49
figure 7-2 Position of the DIP-Switch 1................................................................................50
figure 7-3 Position of the rotary switches..............................................................................51
figure 7-4 Rotary switches and label.....................................................................................51
table 7-5 DIP-switch configuration.......................................................................................52
figure 7-6 DIP-switch 2 for local mode.................................................................................52
figure 9-1 Top view of the Repeater .....................................................................................57
figure 9-2 Fuse terminal .......................................................................................................58
figure 9-3 Position of power supply fuse...............................................................................58
figure 9-4 Position of RAM/RTC battery.............................................................................60
figure 9-5 Position of dummy battery backup module...........................................................61
figure 9-6 Cable configuration of the duplexers ....................................................................61
figure 9-7 Connector panel layout ........................................................................................62
figure 9-8 Top view of an RF module...................................................................................63
M0069A0A.doc
Id.-No 151154
Page 6
23-June-99
User’s manual for Remote Unit MOR701B Power
figure 9-9 Position of hex coded rotary switches...................................................................64
table 9-10 Address of synthesizer .........................................................................................64
figure 9-11 Position of control module .................................................................................65
figure 9-12 Power supply......................................................................................................65
figure 9-13 Position of special-nut M4..................................................................................66
figure 9-14 Position of counter sunk screws on Active Combiner .........................................67
figure 9-15 Position of the feed forward amplifier reset board ..............................................68
figure 9-16 Position of feed forward amplifier (Right-hand side of Repeater) .......................68
figure 9-17 FSK modulator...................................................................................................69
figure 9-18 Installation position............................................................................................69
table 10-1 Spare parts list .....................................................................................................71
figure 11-1 Sample of a configuration list.............................................................................72
figure 12-1 Installation drawing of the Repeater ...................................................................73
figure 12-2 Top view of the Repeater (left-hand side, four channel configuration)................74
figure 12-3 Top view of the Repeater (right-hand side, four channel configuration)..............75
figure 12-4 Block diagram of one channel Repeater .............................................................76
figure 12-5 Cabling of one channel Repeater ........................................................................77
M0069A0A.doc
Id.-No 151154
Page 7
23-June-99
User’s manual for Remote Unit MOR701B Power
LIST OF UNIT SPECIFIC ABBREVIATIONS
ALC
BCCH
BITE
BTS
DL
ETS
FFwd
FSK
Id.-No.
I²C-Bus
LMT
MFY
MOR
OMC
PABX
PCMCIA
PSTN
Rev
RF
RLP
RSSI
RTC
SDA
SCL
UL
UPS
VSWR
M0069A0A.doc
Automatic Level Control
Broadcast Control Channel
Built In Test Equipment
Base Transceiver Station
Downlink
European Telecommunication Standard
Feed Forward Amplifier
Frequency Shift Keying
Ident Number
Inter Integrated Circuit Bus ( Philips )
Local Maintenance Timeout
MIKOM Transceiver
MIKOM Optical Repeater
Operation and Maintenance Centre
Private Automatic Branch Exchange
Personal Computer Modem Communication International Association
Public Switched Telephone Network
Revision
Radio Frequency
Radio Link Protocol
Receive Signal Strength Indication
Real Time Clock
Serial Data Line of I²C-Bus
Serial Clock Line of I²C-Bus
Uplink
Uninterruptable Power Supply
Voltage Standing Wave Ratio
Id.-No 151154
Page 8
23-June-99
User’s manual for Remote Unit MOR701B Power
CONTENTS OF DELIVERY
Qty
Repeater MOR701B Power
Qty
User’s manual for Repeater MOR701B Power
Qty
Set of test protocols consisting of an electrical acceptance test protocol
and a safety test protocol applying to the power supply
Qty
Spare parts kit containing:
- 1 control cable RS232,
- 1 hex socket key, size 2.5
- 1 Torx key
- 5 socket head cap screws M3.0 x 30
- 2 tallow-drop screws TRX M5.0x25
- 2 tallow-drop screws M2.0x6
- 2 tallow-drop screws M3.0x5
- 4 straight pins 3.0 x 25
- 3 captive washers for M5
- 4 Tyraps
- 3x5g Silicon heat conducting paste
- 1 hex socket screw key , size 4, long
- 4 nuts
- 2 fuses 8 A type MT
- 5 socket head cap screws M3.0x20
- 2 countersunk head screw M3.0x20
- 4 special nuts M4
Qty
Wall mounting kit
- 2 mounting brackets
- 4 washers for M8
- 4 socket head cap screws M8.0x16
- 2 tire bolts
Qty
M0069A0A.doc
Wall mounting sheet
Id.-No 151154
Page 9
23-June-99
User’s manual for Remote Unit MOR701B Power
HEALTH AND SAFETY WARNINGS
F Note:
F Note:
F Note:
F Note:
F Note:
F Note:
M0069A0A.doc
The electrical installation has to be performed in accordance with the safety
regulations of the local authorities. Due to safety reasons the electrical
installation must be performed by qualified personnel. The cover of this unit
should not be opened while power is applied. Subsequent installation,
commissioning and maintenance activities that require the unit to be
powered with the cover open shall only be carried out by suitably qualified
personnel.
The grounding of the Unit has to be performed by all means. A grounding
bolt is provided at the cabinet in order to connect the earth bonding cable.
The Unit is heavy-weight. Make sure that a suitable mounting surface is
used. Only adequate manpower is allowed to handle the system.
ESD precautions have to be observed! Before maintenance work use the
available grounding system to connect ESD protection measures.
Due to power dissipation the Repeater may heat up the air volume inside the
cabinet and reach a very high temperature. Therefore the Repeater must be
mounted in the vertical plane to a wall or a mast without additional
enclosure to provide sufficient ventilation. Between the housing and the wall
a minimum distance must be kept in order to provide air circulation.
Laser radiation! Do not stare into the beam or view directly with optical
instruments. Class 3A laser product.
Id.-No 151154
Page 10
23-June-99
User’s manual for Remote Unit MOR701B Power
PREAMBLE
In cellular systems, Repeaters are used to enhance the influence of a base station in regions
where, due to topological conditions, poor field strengths disable communication. MIKOM is
a leading manufacturer of Repeaters. They provide excellent electrical characteristics, they are
light-weight and easy to install. Hence, the MIKOM Repeater is the preferred solution.
Your Repeater has been built using high reliable materials. A comprehensive quality
assurance has been applied to all fabrication steps. This secures constant quality of the
product. Every Repeater leaves the factory only after a thorough final acceptance test,
accompanied by a test certificate, which warrants perfect function. The acceptance test
certificate is subject of the delivery, and it is fixed to the Repeater lid in order to provide a
quick reference for the user.
Any intervention has to be performed by authorized persons only. If you need technical
assistance with the Repeater MOR701B Power approach your local sales office (see table 1-1
List of international sales offices) or MIKOM directly at the following address:
MIKOM GmbH
Industriering 10
86675 Buchdorf
Germany
Tel: +49 (0) 9099 6 90
Fax: +49 (0) 9099 69 31
email: sales@mikom.com
http://www.mikom.com
Under consideration of all references given in this manual, the Repeater should be taken into
service without any complications and should operate trouble-free for a long time.
M0069A0A.doc
Id.-No 151154
Page 11
23-June-99
User’s manual for Remote Unit MOR701B Power
LIST OF INTERNATIONAL SALES OFFICES
Allen Telecom
Allen Telecom (Australia)
P/L
30500 Bruce Industrial Parkway PO Box 903
Cleveland, Ohio 44 139-3996
Bankstown NSW 2200
USA
Australia
Forem France
Phone: +1 ( 216 ) 349-8657
FAX: +1 ( 216 ) 349-8408
Phone: +61 ( 2 ) 9793-9644
FAX: +61 ( 2 ) 9793-9747
Phone: +33-1-30-79-15-30
FAX: +33-1-30-55-55-37
FOREM S.p.A.
AT Singapore
AT China
Via Archimede N. 22/24
20041, Agrate Brianza
Milan
Italy
80 Marine Parade Road
#19-1 Parkway Parade
Singapore 449269
CITIC Building, # 11-05
19 Jiangguomenwai Avenue
Beijing
China 100004
Phone: +39-39-605-41
FAX: +39-39-605-4477
Phone: +65-345-8022
FAX: +65-345-8033
Phone: +86-10-6508-3088
FAX: +86-10-6508-3066
AT Canada
FOREM UK
AT Hong Kong
1815 Ironstone Manor, # 12
Pickering, Ontario L1W 3W9
Canada
Unit D
Castle Industrial Park
Pear Tree Lane
Newbury, Berkshire
U.K. RG 14 2EZ
1603 Remington Certer,
23 Hung to road,
Kwun Tong, Kow Loon
Hong Kong
Phone: +1 ( 905 ) 839-3474
FAX: +1 ( 905 ) 839-4663
Phone: +44-1635-569-695
FAX: +44-1635-569-463
Phone: +852-2389-1844
FAX: +852-2389-4864
Z.I. des Ebisoires
78370 Plaisir
France
AT India
B-256 Ground Floor.
Chittaranjan Park
New Delhi 110019
Phone: +91-11-696-3918
FAX: +91-11-652-1648
table 1-1 List of international sales offices
M0069A0A.doc
Id.-No 151154
Page 12
23-June-99
User’s manual for Remote Unit MOR701B Power
1 Introduction
1.1 Intended purpose
Cellular telephone systems transmit signals in two directions between base stations and
mobile telephones within the signal coverage area.
If weak signal transmissions occur within the coverage area because of indoor applications,
topological conditions or distance from the transmitter, a Repeater is used to extend
transmission range. In the downlink path the Repeater picks up the signal from a donor
antenna of an existing cell, amplifies and re-transmits it into the desired dark spot. In the
uplink direction the Repeater receives signals from mobile stations present in its coverage
area and re-transmits them to the corresponding base station.
1.2 About the MOR701B POWER
MIKOM’s MOR701B Power Remote is available as a band selective optical repeater for
GSM, CDMA and TDMA technology and as a channel selective optical repeater for CDMA
and TDMA technology.
A GSM channel selective version is available (MOR 740).
The MOR701B Power Remote repeater bi-directionally amplifies signals between multiple
mobiles and a single base station in the PCS1900 frequency band using optical fibres for
interconnection to a Master Unit. It is employed mainly in tunnels, canyons, and other areas
where physical structures cause weak field strengths. It can provide highly selective
amplification of band segments or channels in the PCS1900 band.
The MOR701B Power Remote can be combined with other repeaters in order to create a
multi-band optical repeater system. Modules operating in GSM1800, GSM900, AMPS800, or
iDEN bands are available. When different modules are combined a common antenna and
control interface is available.
The MR701 Power Remote can be set-up locally at the Master Unit through the optical fibre
or remotely at the OMC. A PCMCIA slot for modem operation is an available option at the
Master Unit. The repeater has a large number of functions that can be monitored and changed
by the operators via a terminal emulation program or the MIKOM OMC software platform.
An easy to understand and simple to learn communication language is available to help the
operator query status reports from the repeater or to change settings.
M0069A0A.doc
Id.-No 151154
Page 13
23-June-99
User’s manual for Remote Unit MOR701B Power
2 Functional description
The Repeater MOR701B Power can be equipped from one to four bands or channels.
The following block diagram shall illustrate the configuration of the system.
*: one physical module contains UL and DL
**: with more than two channels, the amplifier is included
*** For correct cabling see Assembly Guide
figure 2-1 Block diagram of MOR701B Power
M0069A0A.doc
Id.-No 151154
Page 14
23-June-99
User’s manual for Remote Unit MOR701B Power
2.1 General
The Repeater consists of two amplifier chains. The signals to and from the mobiles are
combined to an antenna by a frequency separation unit, denominated in the following as
Duplexer. The optical signals to and from the Master Unit are converted by the Optical
Transceiver.
In the Downlink direction the optical signals from the Master Unit are converted into RFsignals by the Transceiver (see chapter 2.7). They pass the 4-way-Splitter (see chapter2.9),
which provides the RF-signal for the RF modules. After the RF module (see chapter 2.2) they
are combined by the Active Combiner (see chapter 2.6) and afterwards amplified by the Feed
Forward Amplifier (see chapter 2.12), which provides the required output power. Finally the
signals are fed to the antenna by the Duplexer (see chapter 2.5).
In the Uplink direction the signals from the mobiles are seperated by the Duplexer, get to a
Pre-Amplifier and afterwards to an RF module. The signals are combined by the Active
Combiner then, get converted into optical signals by the Transceiver (see chapter 2.7) and are
finally transmitted to the Master Unit.
In the final amplifier of the Downlink a power detection measures the output power and
controls the gain. In the Uplink the gain is controlled by the Active Combiner to protect the
Optical Transceiver. This power detection is called Automatic Level Control (ALC) (see
chapter 3.3).
2.2 RF modules
The task of the RF modules is to amplify the receive signals and to convert them into an
intermediate frequency. The signals, then, proceed a filter stage comprising of highly selective
filters, and run through a digital controllable attenuator. The attenuation can be set in steps of
2 dB, locally or remotely. By using the same synthesizer frequency, that was used to convert
the signals down to intermediate frequency, the intermediate frequency is mixed up to the
original frequency.
The synthesizer is controlled via an I²C-Bus. In case of a breakdown in mains, gain and
frequency data are non-volatile stored in an EEPROM on board.
See figure 2-2 Top view of an RF module for an exemplary channel or band module.
M0069A0A.doc
Id.-No 151154
Page 15
23-June-99
User’s manual for Remote Unit MOR701B Power
figure 2-2 Top view of an RF module
M0069A0A.doc
Id.-No 151154
Page 16
23-June-99
User’s manual for Remote Unit MOR701B Power
2.3 Mother board
The function of the mother board is the communication between the RF modules and the
control module via the I²C-Bus.
In the three and four channel configuration of the Repeater there is a mother board on the leftand on the right-hand side, whereas in the one and two channel configuration there is only one
mother board implemented on the right-hand side of the Repeater.
Mother boards are located underneath the RF modules.
figure 2-3 Top view of a mother board
M0069A0A.doc
Id.-No 151154
Page 17
23-June-99
User’s manual for Remote Unit MOR701B Power
2.4 Control module SM 2009
The control module SM 2009 is a DOS compatible micro computer. The whole
communication between the operator and the Repeater can be done via the control module. By
using the RS232 interface the Repeater can be controlled locally by using a VT100 terminal,
or a PC emulating the VT100 terminal.
Frequency and gain, power down of RF stages and ALC can be controlled and status
messages can be received remotely via the Master Unit.
The data transfer between the control module SM 2009 and the mother board is realized by
the I²C-Bus system.
The I²C-Bus concept was developed by Philips for the serial connection of integrated circuits
within one device. Two wires, SDA - serial data and SCL - serial clock, carry data between
the devices connected to the bus. Each device is recognized by a unique address and can
operate either as transmitter or receiver.
All MOR701B Power configuration parameters are stored in an EEPROM on the control
module if a power supply failure occurs.
figure 2-4 Top view of the control module
M0069A0A.doc
Id.-No 151154
Page 18
23-June-99
User’s manual for Remote Unit MOR701B Power
2.5 Duplexer
The task of the duplexer is to isolate uplink from downlink, i.e. isolate transmit path from
receive path. The pass bandwidth of the duplexer is the entire width of the uplink band and
the downlink band.
Two frequency - dependent versions of the MOR701B Power are available:
Id - No
UL frequency
DL frequency
147362
1850 - 1885 MHz
1930 - 1965 MHz
148669
1875 - 1910 MHz
1955 - 1990 MHz
Duplexer
RF probe
30 dB
figure 2-5 Top view of the duplexer
M0069A0A.doc
Id.-No 151154
Page 19
23-June-99
User’s manual for Remote Unit MOR701B Power
2.6 Active Combiner
After passing through the RF modules, the signals will be combined by the Active Combiner
module in the UL and in the DL path. The Active Combiner will be followed by the feed
forward amplifier in the DL and by the Transceiver in the UL.
figure 2-6 Top view of an Active Combiner module
2.7 Transceiver MFY1319
The Transceiver MFY1319 is the interface between the optic and the electrical distribution
unit. The function of the Transceiver is to convert the optical signal into an electrical signal
and vice versa.
figure 2-7 Transceiver MFY1319
M0069A0A.doc
Id.-No 151154
Page 20
23-June-99
User’s manual for Remote Unit MOR701B Power
Transceiver
MFY1319
Optical connectors
figure 2-8 Installation position of the Transceiver
The configuration of the connecting pins is shown in the following figure.
connecting pins
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
GND
Rx Alarm normally closed
Tx Alarm common
Vcc
Rx Alarm common
Rx Alarm normally open
Tx Alarm normally closed
Tx Alarm normally open
figure 2-9 Configuration of the connecting pins
2.8 FSK modulator
To enable remote control between the Master Unit and the Remote Units a serial interface will
be implemented, in the following designated as FSK modulator. Signals from the Remote
Unit will be modulated to a 10.7 MHz carrier and are fed to the optical Transceiver to be
transmitted to the Master Unit via optical vibre and vice versa.
M0069A0A.doc
Id.-No 151154
Page 21
23-June-99
User’s manual for Remote Unit MOR701B Power
2.9 4-way-Splitter
The 4-way-Splitter provides the RF-signal to the RF modules. It splits up the signal from the
Receiver and provides four equal RF outputs with an attenuation of 10 dB for the RF
modules. It is mounted underneath the Optical Transceiver and can be seen only, if the
Transceiver is dismounted.
figure 2-10 Top view of the 4-way-Splitter (Transceiver dismounted)
2.10 Measuring aids
With the built-in RF probe test signals can be applied or detected. The duplexer is equipped
with a probe which provides a coupling factor of 30 dB. This facilitates measurements under
all operational conditions, while an antenna or a dummy load may be connected.
The position of the coupler on the duplexer is shown in figure 2-5 Top view of the duplexer.
2.11 Power supply
For the MOR701B Power three power supplies are necessary.
Power supplies are available with different mains power. See list below for available power
supplies.
M0069A0A.doc
Id.-No 151154
Page 22
23-June-99
User’s manual for Remote Unit MOR701B Power
•
115 VAC ± 15% / 40 - 65 Hz
•
230 VAC ± 15% / 40 - 65 Hz
•
185 - 320 VAC / 40 - 65 Hz
•
24 VDC
•
42 to 60 VDC
•
80 to 130 VDC
The following figure shows the mounting position of the power supplies in the MOR701B
Power cabinet.
power socket
(service connector*)
Power supplies
G0850M0
* service connector is not included in each power supply
figure 2-11 Mounting position of power supplies
The power supplies are equipped with a power socket, protected with two fuses. Each power
supply can be switched on or off by means of an external switch. The modules of the Repeater
are voltage free if all power supplies are switched off. The power socket, however, is still
provided with mains power.
See figure 2-12 ON / OFF position of external switch.
M0069A0A.doc
Id.-No 151154
Page 23
23-June-99
User’s manual for Remote Unit MOR701B Power
figure 2-12 ON / OFF position of external switch
F Note:
To switch the whole Repeater voltage free, you have to remove the
fuses F1 and F2 on the screw terminal.
The power supply is factory-set.
2.12 Feed forward amplifier
The feed forward amplifier is the final stage which enables high output power as well as a
high ICP3. One amplifier is installed for the DL Out path.
figure 2-13 Top view of the feed forward amplifier
M0069A0A.doc
Id.-No 151154
Page 24
23-June-99
User’s manual for Remote Unit MOR701B Power
3 Functions and features
3.1 Band and channel selectivity
The selectivity is achieved by highly selective filters in the IF part of the band / channel
modules.
3.2 Gain setting
The gain can be changed by introducing attenuation into the amplifier chain. By using a rotary
switch the attenuation can be adjusted locally in the range from 0 dB to 30 dB maximum in
steps of 2 dB. The attenuation can be set for the UL and DL path separately.
The rotary switches are mounted on the mother board. These switches are accessible through
the long hole between the two RF modules (see figure 3-1 Position of rotary switches). They
can be adjusted easily by means of a small screwdriver.
long hole
figure 3-1 Position of rotary switches
For remote control an RS232 interface can be used to set the gain.
The functions of the control module may be used locally by means of a VT100 terminal or a
personal computer emulating the VT100 terminal. See also chapter 7.2, which deals with
settings of operational parameters.
M0069A0A.doc
Id.-No 151154
Page 25
23-June-99
User’s manual for Remote Unit MOR701B Power
3.3 ALC
In order to protect the final amplifier and the optical devices from overload and to prevent the
system to generate spurious emission, the amplifier for the DL Out and the Active Combiner
for the UL Out have an Automatic Level Control, designed to limit the output power to a
defined level. A part of the output power is rectified, amplified and used to control an
attenuator network. In order to avoid oscillation, the control amplifier has an integrating
characteristic, so that a step function response obtains a delayed rise and decay.
FNote:
The ALC protects the final amplifier and the optical devices. To keep
spurious emissions below certain limits, the input power into the Repeater
and the attenuation settings of the Repeater have to be considered
properly.
3.4 BITE and alarms
The Built-In TEst concept comprises the monitoring of the power supplies, the operational
currents in the RF modules, the mother board and the remote control interface. Furthermore,
the synthesizer lock and the temperature of the Repeater are monitored.
There are three multicoloured LEDs mounted on the control module. The LED L3 indicates
the presence of electrical power of +12VDC in the Repeater. Every alarm is indicated by the
failure LEDs, L1 and L2.
Position of the LEDs on the control module is shown in the following figure.
figure 3-2 Position of failure LEDs
M0069A0A.doc
Id.-No 151154
Page 26
23-June-99
User’s manual for Remote Unit MOR701B Power
All alarms can be checked by typing the ‘STATUS HIST’ command. It is possible to cancel
minor alarms with no influence on the system by typing the ‘ALARMACKN’ command, e.g.
ALC active, VSWR or door open. The following print screen illustrates a possible ‘STATUS
HIST’ report
figure 3-3 Status hist report
In case a hardware failure is detected the concerning hardware module has to be replaced. An
alarm can be acknowledged manually by software command. If all alarms have been
acknowledged the summary error LEDs are set back to green indication.
In case of mains power failure all data of the STATUS HIST list are lost.
The alarm can also be sent to the OMC.
The following list comprises all available alarms in the Repeater. These alarms may occur in
the STATUS HIST list.
M0069A0A.doc
Id.-No 151154
Page 27
23-June-99
User’s manual for Remote Unit MOR701B Power
NO.
(7)
10
11
12
(13*)
(14*)
(15*)
(16*)
(17**)
**
(...)
ALARM NAME
AMPLIFIER BIAS
POWER SUPPLY 8 V
POWER SUPPLY 12 V
MAINS
SYNTH
DOOR
VSWR
ALC
LITHIUM BATTERY VOLTAGE
OVERTEMP
INVALID LOGIN ATTEMPT
I2C BUS
EXT. ALARM 1
EXT. ALARM 2
EXT. ALARM 3
EXT. ALARM 4
EXT. BATTERY
ALARM ACTIVE STATUS
FAILURE
FAILURE
FAILURE
FAILURE
FAILURE
OPEN
ALARM
FAILURE
LOW
FAILURE
FAILURE
FAILURE
FAILURE
FAILURE
OVERTEMP.
Alarm default settings changeable by software instruction SET ALIAS.
This alarm may be activated together with the external alarms, for instance UPS
temperature
Optional alarms
table 3-4 List of all available alarms
3.4.1 Handling of alarms
As soon as the software recognizes a valid alarm, a message is transmitted to theMaster Unit.
If the reason for the alarm has been cleared or if the alarm should continue, a new alarm
message will not be repeated. If there was an interruption of at least one second after
acknowledgement, a new alarm message will be generated.
M0069A0A.doc
Id.-No 151154
Page 28
23-June-99
User’s manual for Remote Unit MOR701B Power
3.4.2 Status report
Two instructions enable the operator to gain knowledge of the system status. Typing the GET
command will be responded by a listing of all settings of the Repeater. STATUS will be
responded by a listing of all individual status information.
An example is listed below for a GET1* (REP1009V1.xx) and STATUS report. The listing
contains random data to demonstrate in which way these messages appear.
*: Due to the fact that the report is very long, the GET report can be split in two parts. You have to type GET1 to
see the first and GET2 to see the second part.
The complete listing of the dialogue language with the processor of the control module
including the instructions to and the messages from the system is available as a separate
manual.
figure 3-5 Example of a GET1 report
M0069A0A.doc
Id.-No 151154
Page 29
23-June-99
User’s manual for Remote Unit MOR701B Power
figure 3-6 Example of a STATUS report
3.4.3 Severity levels
This parameter defines five severity levels for an alarm and can be set in the alarm mask
(detailed description in the software manual). The severity levels indicate how the capability
of the managed object has been affected.
The levels are described below and are ordered from most severe to least severe:
- Critical:
The critical severity level indicates that a service affecting condition has
occurred and an immediate corrective action is required to restore the
capability of the managed object.
- Major:
The major severity level indicates that a service affecting condition has
developed and an urgent corrective action is required. Such a severity can be
reported, for example, when there is a severe degradation in the capability of
the managed object and its full capability must be restored.
- Minor:
The minor severity level indicates the existence of a non-service affecting fault
condition and that corrective actions should be taken in order to prevent a more
serious failure. Such a severity can be reported, for example, when the detected
alarm condition is not currently degrading the capability of the managed object.
M0069A0A.doc
Id.-No 151154
Page 30
23-June-99
User’s manual for Remote Unit MOR701B Power
- Warning:
The warning severity level indicates the detection of a potential or impending
service affecting failure before any significant effect has been caused. Action
should be taken to further diagnose and correction of the problem shall prevent
a more serious service affecting failure.
- Disable:
The disable severity level indicates that the detected failure has no influence on
the system and shall not be sent to the terminal.
M0069A0A.doc
Id.-No 151154
Page 31
23-June-99
User’s manual for Remote Unit MOR701B Power
4 Optional equipment
The following modules can be integrated as an option.
4.1 VSWR module
VSWR signal is continually measured by a special VSWR module. An alarm can be given for
VSWR < 10 dB.
4.2 External alarms
With the following option it is possible to monitor 4 external alarms via the Repeater
software. Hence the status of the connected device, e.g. UPS, can be monitored.
The contacts of the alarms can be accessed at clamps on the main board (right-hand side of
the Repeater).
figure 4-1 Clamps for external alarms
M0069A0A.doc
Id.-No 151154
Page 32
23-June-99
User’s manual for Remote Unit MOR701B Power
The electrical connection has to be as follows.
External alarm 1 (low active)
External alarm 2 (low acitve)
External alarm 3 (high active)
External alarm 4 (high active)
Ground
Configuration: 5 V / 0.5 mA max. for open collector applications.
All external alarms are normally high without connection. Due to the fact that the external
alarms 3 and 4 are high active, they have to be connected to ground to prevent an alarm
message.
The factory-set response after typing the software command STATUS EXTALARM is for
instance „EXT. ALARM 1 OK“, if the alarm is not active and „EXT. ALARM 1 FAILURE“,
if the alarm is active.
The name for each external alarm and the name for the alarm message can be defined by the
customer with the corresponding software command.
The following example describes the response for the external alarms to control a UPS.
Example:
External alarms if the UPS is active
EXTERNAL ALARM STATUS
UPS alarm active
Battery low !
UPS door open
Battery door open
or
External alarms if the UPS is not active
EXTERNAL ALARM STATUS
UPS not active
Battery OK
UPS door closed
Battery door closed
For the DC wiring an additional cable bridge has to be installed on the control module (see
figure 4-2 Cable configuration and installation position).
M0069A0A.doc
Id.-No 151154
Page 33
23-June-99
User’s manual for Remote Unit MOR701B Power
Control module
figure 4-2 Cable configuration and installation position
4.3 Battery backup module
If backup is required only for the control module, low capacity batteries are available to
operate the controller for at least ten minutes under normal environmental conditions.
Battery backup is provided for the control module to transmit alarm information in case of
power failure. The battery type is a NiCd 8.4V/300 mAh.
F Note:
This battery backup module is provided for the control module only.
The batteries are protected from deep discharge by use of a low voltage disconnect circuit. A
local switch is provided to disconnect the battery backup system during maintenance to ensure
that all circuits are voltage-free.
The switch is located on the battery backup module.
Switch
ON ( default )
OFF
Battery backup active Battery backup not active
The module is directly plugged into the control module. During the charging process a green
LED V7 on the module indicates, that the battery is charged at the moment. After finishing
the process the LED V7 will be switched off.
The batteries are mounted underneath the modem mounting plate (see following figure).
M0069A0A.doc
Id.-No 151154
Page 34
23-June-99
User’s manual for Remote Unit MOR701B Power
figure 4-3 Mounting position of batteries
M0069A0A.doc
Id.-No 151154
Page 35
23-June-99
User’s manual for Remote Unit MOR701B Power
5 Specification
5.1 Electrical specification
Frequency range
UL: 1850 - 1885 MHz; DL: 1930 - 1965 MHz
UL: 1875 - 1910 MHz; DL: 1955 - 1990 MHz
Useable bandwidth
35 MHz in the upper or lower PCS1900 band
Gain
65 dB
Gain variation over
frequency and temperature*
±2.5 dB (±3.5 dB at extreme temperatures)
Gain adjust range
30 dB in 2 dB steps
Gain adjust range tolerance
±0.5 dB
Return loss
15 dB @ 25°C ambient temperature
Spurious/intermodulation
-13 dBm max
Spectral re-growth (CDMA only)
-45 dBc (J-STD-008)
Power supply
115 VAC ± 15% / 40 - 65 Hz
Option: 230 VAC ± 15% / 40 - 65 Hz
Option: 185 - 320 VAC / 40 - 65 Hz
Option: 24 VDC
Option: 42 to 60 VDC
RF connector
7/16 female
Option: N female
Environmental and safety
See separate leaflet
*: Normal temperature range +5° to +40°C; Extreme temperature range -33° to +50°C
M0069A0A.doc
Id.-No 151154
Page 36
23-June-99
User’s manual for Remote Unit MOR701B Power
BAND AND CHANNEL SPECIFICATIONS
3 dB bandwidth
Option I
(fixed bw)
5 MHz
Option II
(fixed bw)
15 MHz
Slope 3 dB to 30 dB
1 MHz
2 MHz
2 MHz
30 dB bandwith
fc ± 900kHz
fc ±60 kHz
50 dB bandwith
fc ± 1.5 MHz
fc ± 120 kHz
Delay
6 µs
3 µs
6 µs
< 6 µs
20 µs
Delay variation
(typical)
±150 ns
±150 ns
±150 ns
±500 ns
±500 ns
Far off selectivity
40 dB
40 dB
40 dB
60 dB
55 dB
NF at Gmax
6 dB
6 dB
8 dB
6 dB
6 dB
NF at Gmax-30 dB
12 dB
12 dB
13 dB
12 dB
12 dB
OICP-3 at Gmax
59.0 dBm
59.0 dBm
59.0 dBm
59.0 dBm
59.0 dBm
OICP-3 at Gmax 10 dB
58.6
58.5
58.5
58.5
59.0
dBm
dBm
dBm
dBm
dBm
58.0
58.0
57.5
58.0
58.5
dBm
dBm
dBm
dBm
dBm
56.0
56.0
53.0
55.0
57.0
dBm
dBm
dBm
dBm
dBm
-78 dBm/Hz -78 dBm/Hz -76 dBm/Hz
Output noise out of
-98 dBm/Hz -98 dBm/Hz -96 dBm/Hz
band at Gmax
OICP-3 at Gmax 20 dB
OICP-3 at Gmax 30 dB
Option III
(variable bw)
0.1 to 15
MHz
Channel
CDMA
TDMA
1.23 MHz
30 kHz
Output noise
in band at Gmax
Power consumtion
standby/max power
1 module (typ.cons)
130/220W
130/220W
145/220W
130/210W
130/210W
4 modules (typ.cons)
160/250W
160/250W
180/270W
160/240W
160/240W
All data is subject to change without notice !
M0069A0A.doc
Id.-No 151154
Page 37
23-June-99
User’s manual for Remote Unit MOR701B Power
5.2 Optical specification
Max. allowed optical loss Master / Remote
Required optical return loss
reflection + backscatter
10 dB*
*optical loss up to 13 dB with slightly
degraded specifications
45 dB
5.3 Mechanical specification
Standard cabinet
Max. Height x Width x Depth:
21.1 x 18.2 x 7.9 inches
535 x 462.5 x 200 mm
Volume:
approximately 45 litres
Weight:
approximately 103 lbs (47 kg per unit in standard
configuration)
The illustration of chapter 12.1 provides the dimensions and the view of the layout.
5.4 Environmental and safety
For detailed information refer to the environmental and safety specification leaflet for
MIKOM indoor / outdoor cell enhancers, related to ETS 300019 (European Telecommunication Standard).
Operating temperature (normal temperature range):
(extreme temperature range):
+ 5° C ... + 40° C
- 33° C ... + 50° C
Humidity:
+ 30° C/ 93 %
M0069A0A.doc
Id.-No 151154
Page 38
23-June-99
User’s manual for Remote Unit MOR701B Power
5.5 External electrical interfaces
5.5.1 Electrical power
The Repeater MOR701B Power can be supplied with the following power supplies (mains):
•
115 Vac ± 15% 40 - 65 Hz
•
230 V ac ± 15% 40 - 65 Hz
•
185 - 320 Vac 40 - 65 Hz
•
24 Vdc
•
±42 to ±60 Vdc
•
±80 to ±130 Vdc
A firmly installed mains cable is used, which is fed into the housing through a watertight
cable gland. Due to safety reasons the power supply lead has to be protected by two 8 A fuses.
Inside the Repeater, mains are connected to a screw terminal.
See figure 5-1 Screw terminal for mains cable for the position of the two 8 A fuses.
figure 5-1 Screw terminal for mains cable
M0069A0A.doc
Id.-No 151154
Page 39
23-June-99
User’s manual for Remote Unit MOR701B Power
5.5.2 RF connection
There is a 7/16 female antenna connector at the outside of the housing accessible on the
connector panel.
G0850Z0
figure 5-2 Connector panel layout
The 7/16 TX-downlink connector should be connected to the antenna system for the
communication with the mobile units.
Mobile
As an option a 7/16 - N adapter is available.
5.5.3 Optical connector
The Remote Unit is connected to the Master Unit via optical fibres. Therefore two optical
connectors (DIN, SC/APC or FC/APC) are available at the front side of the Repeater. They
are labelled with RX and TX.
BTS
M0069A0A.doc
Id.-No 151154
Page 40
23-June-99
User’s manual for Remote Unit MOR701B Power
6 Installation
to/from
TX Downlink
RX Uplink
Repeater System
to/from
mobile stations
BTS
Master Unit
Remote
Unit 1
** Remote
... Unit xx.
TX Uplink
RX Downlink
Mobiles
*:
**:
BTS
This is possible alternativly
The number of Remote Units depends on the configuration of the Master Unit
figure 6-1 System description
M0069A0A.doc
Id.-No 151154
Page 41
23-June-99
User’s manual for Remote Unit MOR701B Power
6.1 Mechanical installation
Note:
Due to power dissipation the Repeater may heat up the air volume inside
the cabinet and reach a very high temperature. Therefore it is necessary to mount the
Repeater in the vertical plane to a wall or a mast without additional enclosure to provide
sufficient ventilation. Between the housing and the wall a minimum distance must be
kept in order to provide air circulation.
The Repeater must be mounted in the vertical
plane to a wall or a mast, which means the
connectors have to be located at the bottom.
Use the mounting brackets, which are part of the
delivery. This will guarantee a minimum
distance between the wall and the Repeater
housing. The cabinet must be fixed to the wall
(brackets) with four screws.
Check the correspondence of the wall mounting
kit and the wall.
F Note:
M0069A0A.doc
The weight of the MOR701B Power is approximately 47 kg in standard
configuration.
Id.-No 151154
Page 42
23-June-99
User’s manual for Remote Unit MOR701B Power
Mounting procedure:
Dismount the mounting brackets first. They are screwed tight to the housing with four socket
head cap screws M8.0x16 (see figure below) and two tire bolts.
mounting brackets
figure 6-2 Wall mounting brackets
Use the wall mounting sheet to mark the position of the drilling holes. Drill 4 holes and screw
the mounting brackets to the wall. Attach the upper two socket head cap screws M8.0x16 to
the Repeater housing. Now it is possible to hang the Repeater into the mounting brackets. Fix
then the lower two socket head cap screws M8.0x16 and the 2 tire bolts.
F Note:
The unit is heavy-weight. Make sure that a suitable mounting surface is
used. Only adequate manpower is allowed to handle the system.
The installation position of the Repeater follows from the installation drawing, see figure 12-1
Installation drawing of the Repeater. Make sure that there is free access to the electrical
connections. The allowed bending radius of the connected cables must not be exceeded.
Furthermore the Repeater shall be mounted in a way that there is free access to the individual
units inside the cabinet, while the door of the Repeater is open.
Therefore keep a clearance distance of 1 m on each side, above and below the unit.
See following figure 6-3 Clearance distance.
M0069A0A.doc
Id.-No 151154
Page 43
23-June-99
User’s manual for Remote Unit MOR701B Power
figure 6-3 Clearance distance
M0069A0A.doc
Id.-No 151154
Page 44
23-June-99
User’s manual for Remote Unit MOR701B Power
6.2 Electrical installation
FNote:
ESD precautions have to be observed! Before working inside the cabinet
use the available grounding system to connect ESD protection measures.
The electrical installation has to be performed in accordance with the
safety regulations of the local authorities. Due to safety reasons the
electrical installation must be performed by qualified personnel. The
cover of this unit should not be opened while power is applied.
Subsequent installation, commissioning and maintenance activities that
require the unit to be powered with the cover open shall only be carried
out by suitably qualified personnel
6.2.1 Grounding
Grounding has to be performed by all means. Therefore a grounding bolt is provided at the
cabinet. An earth bonding cable will be mounted in the factory and will be delivered with the
unit. Don’t use the grounding screw for connecting external devices.
The complete grounding kit is part of the delivery schedule.
figure 6-4 Grounding kit
M0069A0A.doc
Id.-No 151154
Page 45
23-June-99
User’s manual for Remote Unit MOR701B Power
6.2.2 Power connection
Before connecting electrical power to the Repeater grounding has to be performed. The
Repeater is equipped with a firmly connected power cord. Due to safety reasons the power
supply lead of the Repeater has to be protected with two 8 A fuses, type MT. In the event the
length of the power cord should not be sufficient it can be replaced by a longer cable.
figure 6-5 Screw terminal
F Note:
If the power supply lead has to be replaced use a cable of the same quality.
6.2.3 Connection of the antenna cable
The Repeater has a female antenna connector 7/16 (or N with adapter). For mounting the
corresponding cable connector we recommend to refer to the applicable documentation of the
respective connector manufacturer. The bending radius of the antenna cable must remain
within its specification. This will warrant proper operation of the system; otherwise changes
in the electrical behaviour of the cable might occur which could cause malfunction of the
Repeater system.
F Note:
M0069A0A.doc
It is sufficient to fix the 7/16 (or N) antenna connector hand-screwed.
Any use of a tool (like tongs) might cause damage to the connector and
thus lead to malfunctioning of the Repeater.
Id.-No 151154
Page 46
23-June-99
User’s manual for Remote Unit MOR701B Power
6.2.4 Connecting fibre optic cables
The standard transmission of the optical signals is carried out by means of an optical fibre pair
for each Remote Unit.
F Note:
Extreme care should be taken when connecting and disconnecting the
fibre optic cable. Scratches and dust significantly affect system
performance and may permanently damage the connector, necessitating
re-termination. Always use protective caps on fibre optic connectors and
receptacles when not used.
The structure of the cable is not critical. However, demands of the site as for example rodent
protection and so on have to be kept in mind.
The optical fibre is a single mode fibre. The type is E9/125 with the following minimum
requirements.
Attenuation
Dispersion
< 0.3 dB/km @ 1300 nm
< 3.5 ps/nm*km @ 1300 nm
The allowed bending radius of the optical fibres must be kept by all means at any time.
The pig tails for the connection between Master and Remote Unit must have a sufficient
length. A protection for the feeding into units has to be given.
The system attenuation of the optical fibres including the connectors must not exceed 10 dB.
Less than 5 dB is desired.
The system attenuation and the attenuation of the opical components have to be determined.
This can be achieved by measuring the attenuation and the reflection with an appropriate
measuring instrument. For pig tails a total value of < 0.4 dB ( measured to a reference plug )
can be assumed due to the dead zone of the reflectometre. These measurements have to be
made with a sufficient length of optical fibre in front of and behind the device to be measured.
The fibre cables should be terminated with the same type of connector (DIN 8° or SC/APC
8°) as is used in the unit. The fibre optic cables are connected to the optical Transceiver and
receiver.
F Note:
M0069A0A.doc
Angled connectors are not compatible with straight optical connectors;
non-compatibility of connectors will result in permanent damage to both
waiting connectors.
Id.-No 151154
Page 47
23-June-99
User’s manual for Remote Unit MOR701B Power
Before connecting the fibre cables, follow the procedures below to ensure proper
performance. It is important that these procedures be performed with care:
1. Remove fibre optic protective caps.
2. Do not bend the fibre optic cable in a tight radius (<4 cm) as this may cause cable damage
and interrupt transmission.
3. Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of the fibre
optic cable that will be inserted in the optical connectors on the donor interface box.
4. Blow the end dry with clean, dry compressed air.
5. Vigorously blow out the laser receptacle with clean, dry compressed air to remove any
particulate matter.
6. Connect the fibre optic cables by inserting the cable end into the laser receptacle and
aligning the key (on the cable end) with the keyed slot.
7. Do not use any index matching gels or fluids of any kind in these connectors. Gels are
intended for laboratory use and attract dirt in the field.
M0069A0A.doc
Id.-No 151154
Page 48
23-June-99
User’s manual for Remote Unit MOR701B Power
7 Setting to work
7.1 Preparation
F Note:
It is not allowed to operate the Repeater without termination of the
antenna connections! The termination can be performed by the antenna
connection as well as a dummy load or the 50-Ohm-terminated connection
of a measuring instrument.
Before bringing the Repeater system into service it is necessary to measure the antenna
isolation. The Repeater system has its maximum available gain when the attenuation is set to
zero. On site the maximum allowed gain is 15 dB less than the value of the antenna isolation.
In order to check the function of the Repeater system on site it is advisable to operate the
Repeater system with 50 Ohm termination. This makes it possible to set the necessary gain
and to test the set value without the necessity of transmitting on air.
In order to perform settings the Repeater has to be opened. Please ensure not to damage the
seals which are on the modules situated on the RF modules inside of the Repeater, because
this would lead to risk the success of warranty claims.
After taking the Repeater into service following signals occur during the boot process.
Internal
LED L1
green
red
Flashes
red short
time
Internal
LED L2
green
red
Flashes red
short time
Internal
LED L3
green
Cause
Power on state,
Software boot starts
Software boot starts
Software is running
table 7-1 LED indication
M0069A0A.doc
Id.-No 151154
Page 49
23-June-99
User’s manual for Remote Unit MOR701B Power
7.2 Setting of operational parameters
Attenuation of the Repeater can be set manually, locally or remotely. Frequency can be set
locally and remotely.
There are three different possibilities to set the operational parameters:
-manual settings by means of rotary switches
-local control via RS232 interface and PC
-remote control via Master Unit
7.2.1 Manual setting of the attenuation by means of rotary switches
The manual mode allows the user to set the required attenuation by means of rotary switches.
With a small screwdriver, which fits through the long holes of the RF modules, the values can
be adjusted by turning the switch carefully to the desired position.
F Note:
To enable manual settings of parameters the mode switch (DIP-Switch 1)
has to be changed from OFF to ON.
The DIP-Switch is mounted on the control module, located on the left-hand side of the
Repeater.
DIP-Switch 1
figure 7-2 Position of the DIP-Switch 1
M0069A0A.doc
Id.-No 151154
Page 50
23-June-99
User’s manual for Remote Unit MOR701B Power
The gain can be set by introducing attenuation into the amplifier chain. By using a rotary
switch the attenuation can be adjusted locally in the range from 0 dB to 30 dB maximum in
steps of 2 dB. The attenuation can be set for the UL and DL path separately.
The rotary switches are mounted on the mother board. These switches are accessible through
the long hole between the two RF modules ( see figure 7-3 Position of the rotary switches).
They can be adjusted easily by means of a small screwdriver.
long hole
figure 7-3 Position of the rotary switches
A label on the RF module, located next to the rotary switch, illustrates the usage of the rotary
switch (see figure 7-4 Rotary switches and label).
figure 7-4 Rotary switches and label
F Note:
Gain can be changed independently for the uplink and downlink path.
DIP-Switch configuration:
M0069A0A.doc
Id.-No 151154
Page 51
23-June-99
User’s manual for Remote Unit MOR701B Power
DIP-Switch
ON
manual
remote mode
n.c.
software download
manually controlled
OFF (default values)
auto
local mode
n.c.
software download
controlled by software
table 7-5 DIP-switch configuration
7.2.2 Settings via personal computer as terminal
Instead of manually setting operational parameters via rotary switches it is also possible to use
the functions of the control module. The local mode for settings via PC has to be set.
Therefore the DIP-Switch 2 has to be at position OFF.
DIP-Switch 2
figure 7-6 DIP-switch 2 for local mode
M0069A0A.doc
Id.-No 151154
Page 52
23-June-99
User’s manual for Remote Unit MOR701B Power
A VT100 terminal or a PC with VT100 emulation can be connected to the control module
SM2009 by a standard RS232 cable, if necessary in connection with an adapter 9 to 25.
Cable Connections PC
9 contact SUB - D- Connector
male
PC
PIN
Control Module SM2009
9 contact SUB - D- Connector
male
RS 232
MOR701B Power
PIN
The following communication mode between control module and VT100 is set initially.
9600 baud - 8 bit - no parity -1 stopbit
These settings can only be changed after connection of the terminal.
Modifications are possible by software commands.
F Note:
M0069A0A.doc
Settings on the Repeater can be performed after the following procedure
only.
Id.-No 151154
Page 53
23-June-99
User’s manual for Remote Unit MOR701B Power
After connecting the PC to the Repeater, following procedure is necessary to get access to the
program.
MIKOM REPEATER MOR701B - SM2009 - SW: REP1007V1.11
ENTER <.>  TO LOGIN
1. Step:
Type the two keys ( . ) FULLSTOP and (↵) ENTER
You have to type the keys:
2. Step:
UserID1 ↵
The input is case sensitive, no blanks. After three mistrial follows
disconnection.
3. Step:
ENTER PASSWORD
You have to enter:
F Note:
↵
ENTER USER ID
You have to enter:
F Note:
P-word1 ↵
The input is case sensitive, no blanks. After three mistrials follows
disconnection.
7.2.3 Remote control via Master Unit
The Remote Unit can be set remotely through the optical interface by devices connected to the
Master Unit.
M0069A0A.doc
Id.-No 151154
Page 54
23-June-99
User’s manual for Remote Unit MOR701B Power
8 Trouble shooting
All Repeaters are factory-set to „Power down disabled“ status, this means the channel group
is active. To switch off the channel group use the software command „PWRDOWN enabled“.
(You find a detailed description in the software manual.)
8.1 Error indication
l = LED on
- = LED off
Internal
LED L1
green
red
Internal
LED L2
green
red
Internal
LED L3
green
Cause
No power.
Check presence of power at
the input; replace fuse
according to chapter 9.3,
check battery backup module
Indicates a
summary failure
8.2 Boot process
Following signals occur during boot process.
Internal
LED L1
green
red
Internal
LED L2
green
red
Internal
LED L3
green
Flashes red
short time
Flashes red
short time
M0069A0A.doc
Id.-No 151154
Page 55
Cause
Power on state, Software boot
starts
Software boot starts
Software is running
23-June-99
User’s manual for Remote Unit MOR701B Power
8.3 Alarm monitoring with the STATUS HIST command
Check alarms with ‘status hist‘ command.
1. If a hardware module is damaged, replace corresponding hardware module.
2. Minor alarms with no influence on the system can be cancelled by confirming the alarm
with the ‘alarmackn’ command, e.g., ALC active, VSWR, RSSI or DOOR OPEN.
3. If all alarms have been acknowledged the summary error LEDs will be set back to green
indication.
4. In case of mains power failure the contents of the actual STATUS HIST list is lost.
For a complete list of available alarms, see table 3-4 List of all available alarms
8.4 Power supply
The output voltage is factory set and should not be changed.
8.5 General remarks
• After a software download previous user settings ( data default values ) might be
overwritten. Before you start a software download save the set values for:
centre frequency
attenuation
ALC threshold
• If an ALC or AMPBIAS alarm occurs during installation or commissioning an user error
might be the cause, due to wrong measurements.
M0069A0A.doc
Id.-No 151154
Page 56
23-June-99
User’s manual for Remote Unit MOR701B Power
9 Maintenance
9.1 General
F Note:
The Repeater does not require preventative maintenance measures.
It is only recommended to replace the RAM/RTC battery
after three years usage as a prophylactic measure. The
nominal lifetime of these batteries is five years under
normal environmental conditions.
In the event of a malfunction it is advantageous to check
the status of the antenna systems as well as the continuity
of the entire cabling including connectors, before replacing
the modules.
Maintenance on the Repeater shall be performed only by
replacing modules. Soldering on printed circuit boards
shall be avoided. In order to sustain warranty take care not
to damage unintentionally the seals on the modules.
The spare part list, consequently, contains only units,
which can be replaced without tuning or complex
soldering work.
figure 9-1 Top view of the Repeater
F Note:
Defect parts should only be replaced by original parts from MIKOM.
All interventions inside the housing are at one’s own risk.
During maintenance ensure that the Repeater has been disconnected from
mains.
Open the lock at the connector panel and remove the cover plate. To open the housing use a
Torx key and unscrew the four Torx screws.
9.2 Replacement of the fuses (mains)
The mains cable is protected with two fuses F1 and F2 8A type MT. They are accessible
inside of the Repeater at the fuse terminal on the right-hand side. Open the screw plug for the
fuse and take out the fuse.
F Note:
Use only fuses of the same type and the same rating when replacing!
See figure 9-2 Fuse terminal for position of the 8A fuses.
M0069A0A.doc
Id.-No 151154
Page 57
23-June-99
User’s manual for Remote Unit MOR701B Power
figure 9-2 Fuse terminal
9.3 Replacement of the power supply fuse
Each power supply is protected with a fuse 10 A / 35 V. The fuse is mounted outside of the
power supply housing.
F Note:
Use only fuses of the same type and the same rating when replacing!
figure 9-3 Position of power supply fuse
9.4 Replacement of the mains cable
The Repeater will be delivered with a firmly connected mains cable.
In case the length of the delivered mains cable should not be sufficient or in case of a defect,
the mains cable can be replaced.
F Note:
Disconnect Repeater from mains first.
M0069A0A.doc
Id.-No 151154
Page 58
23-June-99
User’s manual for Remote Unit MOR701B Power
Remove the clamping profile at the outside of the housing
by pulling at the mains cable. Open the PG9 threaded joint
with a spanner size 17. Inside the housing remove the
plastic cable clip by unscrewing the tallow-drop screw.
Then use a small screwdriver and open the screws of the
fuse terminal.
Now the mains cable
can be removed by
pulling at the cable. For the installation of a new cable
strip the isolation of a new cable to the length of 18 cm.
Put the screw of the cable gland over the cable then use
the joint rubber and pull it over the cable. This will
guarantee a tight connection. Now insert the cable.
Inside the housing pull an insulated tube with the length
of 8 cm over the wires. Now close the PG9 threaded
joint. Screw the wires to the fuse terminal. Fix the cable
with the plastic cable clip.
Put the cable in the guide shaft and close it with the clamping profile.
9.5 Replacement of the RAM / RTC battery
The RAM / RTC battery of the control module has to be replaced in case of memory loss or
as a preventive measure after approximately three years usage. The RAM / RTC battery is
mounted on the left-hand side of the Repeater underneath the dummy battery backup module
First remove the whole dummy battery backup module ( see figure 9-5 Position of dummy
battery backup module ), which is plugged into the control module. Take off the Lithium
battery by means of a small screwdriver, placed between the battery and the battery socket.
The type of the battery is CR 2450 Lithium 3 V / 500mAh, manufacturer is RENATA.
After replacement of the RAM battery, the control module has its basic settings, date and time
have to be set to the actual value.
M0069A0A.doc
Id.-No 151154
Page 59
23-June-99
User’s manual for Remote Unit MOR701B Power
dummy battery backup module
RAM/RTC battery
figure 9-4 Position of RAM/RTC battery
F Note:
Before replacing the battery, disconnect the Repeater from mains.
Observe the rules for changing Lithium batteries. Wrong connection or
treatment may result in bursting of the battery and dissemination of
hazardous substances.
Don’t try to charge this battery.
9.6 Replacement of the dummy battery backup module
The dummy battery backup module is accessible after opening the housing on the left-hand
side.
Before you are able to remove the module from the socket, release the three snap-in lockings.
M0069A0A.doc
Id.-No 151154
Page 60
23-June-99
User’s manual for Remote Unit MOR701B Power
dummy battery backup module
figure 9-5 Position of dummy battery backup module
9.7 Replacement of the duplexer
This description is valid for the one channel configuration of the Repeater only. For different
configurations refer to the assembly guide for the Repeater.
Remove the semi-rigid cables which connect the DL Output with the feed forward amplifier
by loosening the SMA connector. Use a torque wrench. Then remove the semi-rigid cable
from the mother board.
It is recommended not to remove the amplifier which is mounted on the backside of the
duplexer. A new duplexer will be delivered with a premounted amplifier.
The cables have to be connected as shown below.
G0850M1
figure 9-6 Cable configuration of the duplexers
M0069A0A.doc
Id.-No 151154
Page 61
23-June-99
User’s manual for Remote Unit MOR701B Power
Unscrew the four counter sunk screws M3 at the connector panel of the Repeater. See figure
9-7 Connector panel layout.
G0850Z0
figure 9-7 Connector panel layout
9.8 Replacement of RF modules
To remove the RF modules, disconnect the SMA connectors by means of a torque wrench.
If the Repeater is equipped with TDMA modules, the external filter on top of the modules
must be dismounted beforehand. The external filter box covers two of the socket head cap
screws the TDMA module is fixed with.
Unscrew the socket head cap screw on top of the external filter box, pull the box carefully off
and continue the dismounting procedure as described below.
Unscrew six socket head cap screws by means of a hex socket key.
Pull carefully by means of the mounting strap, fixed on the module (see figure 9-8 Top view
of an RF module) and take off the module.
M0069A0A.doc
Id.-No 151154
Page 62
23-June-99
User’s manual for Remote Unit MOR701B Power
Socket head cap
screws
Mounting
strap *
*: TDMA and CDMA modules are equipped with mounting straps on the left and on the right side.
figure 9-8 Top view of an RF module
Connecting the RF modules depends on the number of channels your Repeater is equipped
with, i.e. with one up to four channels. Each configuration has got a different cabling. See
assembly guide of the channel modification kits for the cabling of the RF modules dependent
on the configuration of the Repeater.
M0069A0A.doc
Id.-No 151154
Page 63
23-June-99
User’s manual for Remote Unit MOR701B Power
For the exchange of an RF module
or the installation of a new RF
module, the slave address of the synthesizer
has to be set. This can be done by means
of hex-coded rotary switches mounted
on the lower side of the modules
(figure 9-9 Position of hex coded rotary switches).
Hex-coded rotary switch
for DL
Hex-coded rotary switch
for UL
figure 9-9 Position of hex
coded rotary switches
The synthesizer address must be set like shown in the following table:
Address
UL
DL
RF module
Channel one
Channel two
Channel three
Channel four
table 9-10 Address of synthesizer
Instructions for band selective modules with variable bandwith can be found in a seperate
document.
9.9 Replacement of the control module SM 2009
The control module is a Printed Circuit Board situated on the left-hand side of the Repeater.
Disconnect the DC cable from power supply.
Disconnect the flat cable.
Remove the battery backup module and remove the Tyrap which is fixed to the control
module.
Take off the whole control module completely with mounting plate by unscrewing four tallow
drop screws M4.
M0069A0A.doc
Id.-No 151154
Page 64
23-June-99
User’s manual for Remote Unit MOR701B Power
For mounting proceed in reverse order.
Position of the control module in the Repeater is illustrated in figure 9-11 Position of control
module.
figure 9-11 Position of control module
9.10 Replacement of power supplies
F Note:
Ensure that mains are disconnected.
There are three power supplies mounted in the Repeater housing, two on each side. Open the
Repeater to get access to the devices.
Remove all connected cables from the clamps of the power supply. Try to loose the plug by
means of a small screwdriver placed between the plug and socket.
ON
Fuse 10A / 35V
figure 9-12 Power supply
M0069A0A.doc
Id.-No 151154
Page 65
23-June-99
User’s manual for Remote Unit MOR701B Power
The power supply is fixed to the Repeater housing by means of two special nuts M4. After
loosening the screws the power supply can be removed. To open these screws a special key
with a spherical head is required (This key is part of the delivery). Place a small screwdriver
between the Repeater housing and the power supply to loose the device.
figure 9-13 Position of special-nut M4
F Note:
Don’t forget to put heat conducting paste on the mounting side for
installation of a new power supply. Use the conducting paste, which is
included in the spare parts kit.
9.11 Replacement of Active Combiner modules
The Active Combiner modules are mounted on both sides of the Repeater.
Disconnect all SMA connectors by means of a torque wrench.
Unscrew two counter sunk screws M3x20mm. See figure 9-14 Position of counter sunk
screws on Active Combiner.
M0069A0A.doc
Id.-No 151154
Page 66
23-June-99
User’s manual for Remote Unit MOR701B Power
counter
sunk
screws
figure 9-14 Position of counter sunk screws on Active Combiner
The cabling of the Active Combiners depends on the configuration of the Repeater. For
correct connections see assembly guide for the channel modification kits.
9.12 Replacement of feed forward amplifier
There is one amplifier mounted on the right-hand side of the Repeater. It is fixed to the
housing by means of 6 socket head cap screws M4x25.
A special reset board is connected to the 15 pole SUB-D connector. (see figure 9-15 Position
of the feed forward amplifier reset board)
This reset board is part of the feed forward amplifier. A new feed forward amplifier will be
delivered with a premounted reset board.
M0069A0A.doc
Id.-No 151154
Page 67
23-June-99
User’s manual for Remote Unit MOR701B Power
Reset board
figure 9-15 Position of the feed forward amplifier reset board
Remove the ready made cable which is plugged to the 15 pole SUB-D connector of the reset
board. Unscrew the screw clip first.
The SMA connectors can be removed only after dismounting the amplifier.
Position of the feed forward amplifier is illustrated in figure 9-16 Position of feed forward
amplifier (Right-hand side of Repeater).
feed
forward
amplifier
figure 9-16 Position of feed forward amplifier (Right-hand side of Repeater)
M0069A0A.doc
Id.-No 151154
Page 68
23-June-99
User’s manual for Remote Unit MOR701B Power
9.13 Replacement of the FSK modulator
To remove the FSK modulator disconnect all connected cables. Remove the two tallow drop
screws which connect the FSK modulator with the MFY1319. The device can be removed.
figure 9-17 FSK modulator
9.14 Replacement of the Transceiver MFY1319
To remove the Transceiver dismount the FSK modulator which is fixed with two screws M3
on top of the Transceiver. Disconnect all cables. Then unscrew the four counter sunk screws
M3 at the connector panel. Now you can remove the Transceiver MFY1319.
FSK modulator
Transceiver MFY
figure 9-18 Installation position
M0069A0A.doc
Id.-No 151154
Page 69
23-June-99
User’s manual for Remote Unit MOR701B Power
10 Spare parts list
The following list contains all parts available for the MOR701B Power . The configuration of
the delivered unit meets the requirements of the customer and can differ depending on the
state of delivery.
Designation
Id.-No.
Mounting material
Basic Module
Extension Module
Basic Module TDMA
Extension Module TDMA
Basic Module CDMA
Extension Module CDMA
Basic Module var. BW
Extension Module var. BW
Conversion Module 5 MHz
Conversion Module 15 MHz
PCS Duplexer UL Input 1850.0 - 1885.0 MHz
PCS Duplexer UL Input 1875.0 - 1910.0 MHz
Feedforward Amplifier 1930 - 1990 MHz
Transceiver MFY1319 DIN Connector
Transceiver MFY1319 SC Connector
FSK Modulator 10,7 MHz
Power Supply 115 Vac ±15% 40 - 65 Hz USA plug
Power Supply 230 Vac ±15% 14 - 65 Hz Ger plug
Power Supply 230 Vac ±15% 14 - 65 Hz UK plug
Power Supply 230 Vac ±15% 14 - 65 Hz no plug
Power Supply 24Vdc no plug
Power Supply 185 - 320 Vac 40 - 65 Hz no plug
Power Supply ±42 - ±60 Vdc no plug
Power Supply ±80 - ±130 Vdc no plug
SW MOB100 V1.10
Control Unit SM2009
SW SLV1007 V1.01
SW SLV1009 V1.04
Manual SW SLV1009 V1.xx
Dummy Battery Backup Module
Battery Backup Module
Sparepart Kit
Wall mounting Kit
Main Board 26V version
Main Board 26V version
Active Combiner DL 1930 - 1990 MHz
Active Combiner UL 1850 - 1910 MHz
150521
148702
148705
148703
148706
148704
148707
148714
148945
148716
148717
144382
144384
148628
143094
146616
145820
141230
138305
142832
144306
145504
148812
144946
145524
143055
143051
146278
147956
148354
143750
143052
146200
146179
149778
149777
148685
148887
M0069A0A.doc
Id.-No 151154
Page 70
23-June-99
User’s manual for Remote Unit MOR701B Power
4-way-Splitter
Termination Resistor
Ready-made cable data
Ready-made cable DC
Ready-made cable data
Ready-made cable DC
Ready-made cable DC female headers 6 contacts
4 External Alarms option Kit
Adapter 7/16 male N female
Mother board
Manual for MOR701B Power
Assembly guide for modification kits
Modification Kit for one channel
Modification Kit for two channels
Modification Kit for three channels
Modification Kit for four channels
150730
33167
149936
149928
148576
149648
150753
147710
112425
147024
151154
151045
149917
149918
149919
149920
table 10-1 Spare parts list
M0069A0A.doc
Id.-No 151154
Page 71
23-June-99
User’s manual for Remote Unit MOR701B Power
11 Configuration list
The actual configuration of the Repeater system has been entered on a separate list at
delivery. This configuration list is subject of the delivery schedule providing actual
information of part number, Id. number, serial number and revision status of the Repeater.
Whenever parts should be replaced the user is kindly asked to update the list.
See sample below:
Remote Unit MOR701B
Id.-No.: 147362
SN:
Part name
Id.-No.
Rev
SN
Basic Module
Extension Module
Power Supply
Duplexer UL input
Feed Forward amplifier
Transceiver MFY1319
FSK Modulator 10.7 MHz
Control Unit SM2009
SW SLV100x
Battery Backup Module
Mother Board
SW MOB100
Connecting Board
Active Combiner
***
***
***
***
***
***
Date: _________________
QA: ________________________
figure 11-1 Sample of a configuration list
M0069A0A.doc
Id.-No 151154
Page 72
23-June-99
User’s manual for Remote Unit MOR701B Power
12 Appendix
12.1 Installation drawing of the Repeater
figure 12-1 Installation drawing of the Repeater
M0069A0A.doc
Id.-No 151154
Page 73
23-June-99
User’s manual for Remote Unit MOR701B Power
12.2 Top view of the Repeater (left-hand side , four channel configuration)
figure 12-2 Top view of the Repeater (left-hand side, four channel configuration)
M0069A0A.doc
Id.-No 151154
Page 74
23-June-99
User’s manual for Remote Unit MOR701B Power
12.3 Top view of the Repeater (right-hand side, four channel configuration)
figure 12-3 Top view of the Repeater (right-hand side, four channel configuration)
M0069A0A.doc
Id.-No 151154
Page 75
23-June-99
User’s manual for Remote Unit MOR701B Power
12.4 One channel configuration –block diagram and cabling
figure 12-4 Block diagram of one channel Repeater
M0069A0A.doc
Id.-No 151154
Page 76
23-June-99
User’s manual for Remote Unit MOR701B Power
figure 12-5 Cabling of one channel Repeater
M0069A0A.doc
Id.-No 151154
Page 77
23-June-99
User’s manual for Remote Unit MOR701B Power
13 Index
Abbreviations 8
Active Combiner 20, 66
Address of MIKOM 11
Alarm monitoring 56
Alarms
External alarms 32
Handling of 28
Indication of 26
List of all alarms 28
ALC 26
Antenna connector 40
Antenna connectors 46
Antenna isolation 49
Gain
Local settings 25, 51
Setting via PC 52
Grounding 45
Health and safety warnings 10
I²C-Bus 18
Ident numbers 70
Installation
Electrical 46
Mechanical 42
Interfaces 18
RS232 18
International sales offices 12
Battery backup 34
BITE 26
Boot process 55
LEDs 26
Local settings 50
Channel
Setting via PC 52
Clamping profile 59
Connector type
7/16 female 40
Contents of delivery 9
Control module 18
Maintenance 57
Measurements of
VSWR signals 32
MFY1319 20
Mother board 17
Mounting brackets 43
DIP-Switch 51
Dummy battery backup module 60
Duplexer 19, 61
Optical connectors 40
Optional modules 32
EEPROM 18
Environmental and safety 38
ESD precautions 11
Power supply 22
Replacement of 66
Feed forward amplifier 24
Fibre optic cable 47
FSK modulator 21
M0069A0A.doc
Id.-No 151154
Page 78
23-June-99
User’s manual for Remote Unit MOR701B Power
RAM / RTC battery 59
Remote control 25
via Master Unit 54
RF module 62
Rotary switch
To set the gain 51
Setting of operational parameters 50
Setting to work 49
Severity levels 30
Specifications
Optical 38
Splitter 22
Status report 29
Test probe 22
Transceiver MFY 20
Trouble shooting 55
M0069A0A.doc
Id.-No 151154
Page 79
23-June-99

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res
Creator                         : Microsoft Word
Create Date                     : Freitag, 25. Juni 1999 08:20
Title                           : M0069A0A.PDF
Author                          : 
Producer                        : Acrobat PDFWriter 3.02 für Windows
Subject                         : 
Modify Date                     : 1999:06:25 08:26:33
Page Count                      : 79
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BCR-RPT-MOR701

Navigation menu