Bauer Compressors B-RFID RF ID Reader in Air Fill Station User Manual Part 4
Bauer Compressors, Inc RF ID Reader in Air Fill Station Users Manual Part 4
Contents
- 1. Users Manual Part 1
- 2. Users Manual Part 2
- 3. Users Manual Part 3
- 4. Users Manual Part 4
Users Manual Part 4
UNICUS 4i CHAPTER 9: CFS III MAINTENANCE 9.1 Description WARNING 9.2 Fill Station Air Flow 9.3 Maintenance 9.3.1 General Maintenance MNL-0021 9.3.2 Nonadjustable Valves 9.3.3 Pressure Gauges 9.3.4 Safety Valves Figure 9-1 9.3.5 Pneumatic Connections WARNING UNICUS 4i 9.3.6 Bearings for Bottle Door Pivot Setscrew diameter Hex size 9.3.7 Pressure Hoses 9.3.8 Door Gas Spring Figure 9-2 Recommended torque (inch lbs) MNL-0021 9.4 Replacement Parts List 9.4.1 CFS III Assemblies Figure 9-3 Item Qty Part No. Description Notes UNICUS 4i Figure 9-4 Item Qty Part No. Description Notes MNL-0021 Figure 9-5 Item Qty Part No. Description Notes UNICUS 4i Figure 9-6 Item Qty Part No. Description Notes MNL-0021 Figure 9-7 Item Qty Part No. Description Notes UNICUS 4i 9.5 Fill Hose Assemblies Figure 9-8 Item Qty Part No. Description Notes scuba fill only 8 10 UNICUS 4i Figure 9-9 Item Qty Part No. Description Notes MNL-0021 Figure 9-9 (cont.) Item Qty Part No. Description Notes UNICUS 4i CHAPTER 10: UNICUS III HP AIR STORAGE 10.1 Bottle Specifications 10.1.1 ISO/UN; ISO 9809-PART2 / United Nations ISO / UN Vessel 4,500 psig 5,000 psig Material Volume Working Pressure Test Pressure Diameter Height Weight Cylinder Valve Finish 10.1.2 ASME; American Society of Mechanical Engineers 6,000 psig MNL-0021 ASME Vessel 5,250 psig Material Volume Working Pressure Test Pressure Diameter Height Weight Cylinder Valve Finish 10.2 Description and Maintenance 10.2.1 Description 6,600 psig UNICUS 4i Figure 10-1 10.2.2 Maintenance 10.2.2.1 10.2.2.2 MNL-0021 10.2.2.3 10.2.2.4 Figure 10-2 10.2.2.5 UNICUS 4i 10.3 Autocascade System 10.3.1 General Figure 10-3 CV PMV PT REG RV SV MNL-0021 10.3.2 Electrical 10.3.3 Filling the Storage Banks 10.3.4 Filling Bottles from the Storage Banks 10.3.5 Manual Bypass UNICUS 4i CHAPTER 11:APPENDIX 11.1 Safety 11.1.1 General Safety Precautions MNL-0021 UNICUS 4i 11.1.2 Safety Warning Labels MNL-0021 11.2 Unpacking, Handling and Installation 11.2.1 Unpacking and Handling Figure 11-1 WARNING UNICUS 4i 11.2.2 Installation of the Compressor Unit 11.2.2.1 CAUTION Figure 11-2 MNL-0021 11.2.2.2 11.2.2.2.1 11.2.2.2.2 11.2.2.2.3 Intake and Exhaust Openings Dependent on Room Volume (V) and Height (h) Drive Hp V = 1750 ft³ h = 6.5 ft Intake (ft²) Exhaust (ft²) V = 3500 ft³ h = 10 ft Intake (ft²) Exhaust (ft²) V = 7000 ft³ h = 13 ft Intake (ft²) Exhaust (ft²) UNICUS 4i 11.2.2.2.4 Intake & Exhaust Openings Dependent on Room Volume (V) and Height (h)a Drive Hp a. V = 1750 ft³ h = 8 ft V = 3500 ft³ h = 10 ft V = 7000 ft³ h = 13 ft Intake (ft²) Intake (ft²) Intake (ft²) Exhaust cfm Exhaust cfm Exhaust cfm The intake sizes given in the above table are for a cooling Gas velocity of 1000 ft.min. Bauer re commends that the cooling Gas velocity be in the range of 600 ft.min. to 2000 ft.min. 11.2.3 Intake Gas 11.2.3.1 MNL-0021 11.2.3.2 11.2.4 Compressor Intake Piping Guideline for Intake Piping with Max. Four 90° bends Inlet Capacity Distance Pipe Diametera a. Add 1” of pipe diameter if the number of 90° bends exceeds four UNICUS 4i 11.2.5 Installation Procedures Figure 11-3 11.2.6 Electrical Installation 11.2.6.1 11.2.6.2 MNL-0021 Figure 11-4 1 PHASE Motor Hp Fuse Amps a Full Load Amps 120 V 208 V 230 V 120 V a. Dual element time dela y fuse Amps. b. Normal Copper wire with THW, TH WN, o r XHHW insulation. 208 V 230 V Minimum Wire Sizeb 120 V 208 V 230 V UNICUS 4i 3 PHASE Full Load Amps Motor Hp 208 V 230 V 460V Fuse Amps a 208 V a. Dual element time delay fuse Amps. b. Normal Copper wire with THW, TH WN or XHHW insulation. c. mcm = 1,000 circular mils 230 V 460V Minimum Wire Sizeb 208 V 230 V 460V MNL-0021 11.2.7 Pneumatic Leaks WARNING 11.3 Long Term Storage 11.3.1 General 11.3.2 Preparations 11.3.2.1 11.3.3 Preserving the Compressor UNICUS 4i 11.3.4 Preventive Maintenance During Storage 11.3.5 Lubrication Oils for Preservation 11.3.6 Reactivating the Compressor Unit MNL-0021 11.4 Reproducible Forms 11.4.1 Scheduled Maintenance Form Daily Para. Date Signature UNICUS 4i Weekly or as required. Para. Date Signature 500 Operating Hours. Para. Date Signature 1,000 Operating Hours. Para. Date Signature 2,000 Operating Hours. Para. Date Signature MNL-0021 3,000 Operating Hours. Para. Date Signature Annually. Para. Date Signature Biennially. (Every two years) Para. Date Signature UNICUS 4i 11.4.2 Cartridge Operating Hours Date Operating hours Ambient temp. + 18°F during compression Correction factor Adjusted cartridge hours Today Total MNL-0021 11.4.3 Record of Operating Hours Date Minutes Total Date Minutes Total UNICUS 4i 11.5 Reference Data 11.5.1 Tightening Torque Values Table 11-1: Bolt or Screw Size Max. Torque 11.5.2 Torque Sequence Diagrams Figure 11-5 11.5.3 Conversion Formulas MNL-0021 11.5.4 Approved Lubricants Chart Table 11-2: Usage 11.5.5 Glossary of Abbreviations and Acronyms G A o T H c I A F P D p S c Lubricants UNICUS 4i 11.6 Additional Documents 11.6.1 Diagrams and Drawings 11.6.2 Other Documents CORRECTIONS & COMMENTS documentation@bauercomp.com Submitters Contact Information: Unit Information:
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 41 Warning : Duplicate 'Im126' entry in dictionary (ignored) Author : Create Date : 2017:12:14 17:14:29-06:00 Creator : Modify Date : 2017:12:14 17:14:29-06:00 Producer : Foxit PhantomPDF Printer Version 8.3.1.0522 Subject : Title :EXIF Metadata provided by EXIF.tools