Bird Technologies Group 5PI62 Signal Booster (Bi-directional Amplifier) User Manual
Bird Technologies Group Signal Booster (Bi-directional Amplifier) Users Manual
Users Manual
SYSTEMS INC. Installation and Operation Manual for Series 62 Signal Boosters Manual Part Number 7-9470 TX RX Systems Inc. 8625 Industrial Parkway, Angola, NY 14006 Tel: 716-549-4700 Fax: 716-549-4772 sales@txrx.com www.txrx.com Warranty This warranty applies for one year from shipping date. TX RX Systems Inc. warrants its products to be free from defect in material and workmanship at the time of shipment. Our obligation under warranty is limited to replacement or repair, at our option, of any such products that shall have been defective at the time of manufacture. TX RX Systems Inc. reserves the right to replace with merchandise of equal performance although not identical in every way to that originally sold. TX RX Systems Inc. is not liable for damage caused by lightning or other natural disasters. No product will be accepted for repair or replacement without our prior written approval. The purchaser must prepay all shipping charges on returned products. TX RX Systems Inc. shall in no event be liable for consequential damages, installation costs or expense of any nature resulting from the purchase or use of products, whether or not they are used in accordance with instructions. This warranty is in lieu of all other warranties, either expressed or implied, including any implied warranty or merchantability of fitness. No representative is authorized to assume for TX RX Systems Inc. any other liability or warranty than set forth above in connection with our products or services. TERMS AND CONDITIONS OF SALE PRICES AND TERMS: Prices are FOB seller’s plant in Angola, NY domestic packaging only, and are subject to change without notice. Federal, State and local sales or excise taxes are not included in prices. When Net 30 terms are applicable, payment is due within 30 days of invoice date. All orders are subject to a $100.00 net minimum. QUOTATIONS: Only written quotations are valid. ACCEPTANCE OF ORDERS: Acceptance of orders is valid only when so acknowledged in writing by the seller. SHIPPING: Unless otherwise agreed at the time the order is placed, seller reserves the right to make partial shipments for which payment shall be made in accordance with seller’s stated terms. Shipments are made with transportation charges collect unless otherwise specified by the buyer. Seller’s best judgement will be used in routing, except that buyer’s routing is used where practicable. The seller is not responsible for selection of most economical or timeliest routing. CLAIMS: All claims for damage or loss in transit must be made promptly by the buyer against the carrier. All claims for shortages must be made within 30 days after date of shipment of material from the seller’s plant. SPECIFICATION CHANGES OR MODIFICATIONS: All designs and specifications of seller’s products are subject to change without notice provided the changes or modifications do not affect performance. RETURN MATERIAL: Product or material may be returned for credit only after written authorization from the seller, as to which seller shall have sole discretion. In the event of such authorization, credit given shall not exceed 80 percent of the original purchase. In no case will Seller authorize return of material more than 90 days after shipment from Seller’s plant. Credit for returned material is issued by the Seller only to the original purchaser. ORDER CANCELLATION OR ALTERATION: Cancellation or alteration of acknowledged orders by the buyer will be accepted only on terms that protect the seller against loss. NON WARRANTY REPAIRS AND RETURN WORK: Consult seller’s plant for pricing. Buyer must prepay all transportation charges to seller’s plant. Standard shipping policy set forth above shall apply with respect to return shipment from TX RX Systems Inc. to buyer. DISCLAIMER Product part numbering in photographs and drawings is accurate at time of printing. Part number labels on TX RX products supersede part numbers given within this manual. Information is subject to change without notice. Bird Technologies Group TX RX Systems Inc. Manual Part Number 7-9470 Copyright © 2008 TX RX Systems, Inc. First Printing: February 2009 Version Number Version Date 02/14/09 1.1 04/27/09 Symbols Commonly Used WARNING ESD Electrostatic Discharge CAUTION or ATTENTION Hot Surface High Voltage Electrical Shock Hazard Heavy Lifting Bird Technologies Group NOTE Important Information TX RX Systems Inc. For Class A Unintentional Radiators This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide resonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense. WARNING: Changes or modifications which are not expressly approved by TXRX Systems Inc. could void the user’s authority to operate the equipment. ATTENTION: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Table of Contents Overview............................................................................................................... 1 Unpacking ............................................................................................................ 3 Block Diagram Description................................................................................. 4 Front-End Module ................................................................................................ 4 Power Amplifier Module....................................................................................... 5 Front Panel Module ............................................................................................. 6 Power Entry/Supply ............................................................................................. 7 Connections......................................................................................................... 8 Alarm Conditions................................................................................................. 8 Installation............................................................................................................ 9 Location ............................................................................................................. 9 Mounting .......................................................................................................... 10 Antenna Isolation ............................................................................................. 10 Required Equipment ....................................................................................... 10 Measurement Procedure ................................................................................ 10 Installation Procedure ...................................................................................... 11 Operation............................................................................................................ 11 Variable Step Attenuator .................................................................................. 11 OLC (Automatic Level Control) ......................................................................... 12 RF Exposure ...................................................................................................... 12 Diagnostic Guide ............................................................................................... 13 Gain Reduction.................................................................................................. 13 Excessive Intermodulation or Spurious ............................................................. 13 Occasional Drop-out of Some channels ............................................................ 13 Optional Sampler Ports ..................................................................................... 13 Figures and Tables Figure 1A: Front View of the Unit ........................................................................ 2 Figure 1B: Rear View of the Unit ......................................................................... 2 Figure 2: System Interconnect Diagram ............................................................... 4 Figure 3: Front-End Module Block Diagram ......................................................... 5 Figure 4: Power Amplifier Module Block Diagram ................................................ 6 Figure 5: Front Panel Module Block Diagram....................................................... 7 Figure 6: Power Entry/Supply ............................................................................... 7 Figure 7: Remote Alarm Sensing Connector ........................................................ 8 Figure 8: Mechanical Dimensions ....................................................................... 9 Figure 9: Measuring Antenna Isolation ............................................................... 10 Figure 10: Front Panel ........................................................................................ 12 Table 1: Series 62 Models..................................................................................... 1 Table 2: Specifications .......................................................................................... 3 Table of Contents Manual 7-9470-1.1 04/27/09 Changes to this Manual We have made every effort to ensure this manual is accurate. If you discover any errors, or if you have suggestions for improving this manual, please send your comments to our Angola, New York facility to the attention of the Technical Publications Department. This manual may be periodically updated. When inquiring about updates to this manual refer to the manual part number and revision number on the revision page following the front cover. Contact Information Sales Support at 716-549-4700 extension 5043 Customer Service at 716-549-4700 extension 5044 Technical Publications at 716-549-4700 extension 5019 Table of Bird Contents Technologies Group Manual 7-9470-1.1 TX RX Systems Inc.04/27/09 for single band models and either a 2 Watt or 10 Watt downlink output level @ 1 db compression for dual band models. Table 1 lists all of the models available as well as their uplink / downlink passbands and downlink output power. OVERVIEW Signal Boosters extend radio coverage into areas where abrupt RF propagation losses prevent reliable communication. No frequency translation (conversion) occurs with this device. The Series 62 signal booster is a broadband, bi-directional signal booster that has dual RF paths (uplink and downlink) to extend coverage in RF shielded environments. The signal boosters have either a 1 Watt or 10 Watt downlink output level @ 1dB compression The Series 62 signal booster couples a low noise figure with a wide dynamic range to provide excellent selectivity for operation in a shared frequency band. The signal booster is based on a duplexed Model Number Uplink Band Downlink Band Downlink Output Power 62-89-A15-01-T3 806 - 821 851 - 866 1W 62-89-A15-03-T3 806 - 821 851 - 866 10 W 62-90A-A03-01-T3 821 - 824 866 - 869 1W 62-90A-A03-03-T3 821 - 824 866 - 869 10 W 62-89B-A03-01-T3 806 - 809 851 - 854 1W 62-89B-A03-03-T3 806 - 809 851 - 854 10 W 62-89A-A18-01-T3 806 - 824 851 - 869 1W 62-89A-A18-03-T3 806 - 824 851 - 869 10 W 62-88A-A06-01-T3 896 - 902 935 - 941 1W 62-88A-A06-03-T3 896 - 902 935 - 941 10 W 62-91A-A25-01-T3 824 - 849 869 - 894 1W 62-91A-A25-03-T3 824 - 849 869 - 894 10 W 62-83E-ADB-02-T3 806 - 824 851 - 869 2W 62-83E-ADB-04-T3 806 - 824 851 - 869 10 W 62 - 89A - A18 - 03 - T3 FREQUENCY BAND TYPE 62 83E 88A 89 89A 89B 90A 91A 764 896 806 806 806 821 824 869 941 866 869 854 869 894 BANDWIDTH MHz MHz MHz MHz MHz MHz MHz A03 A06 A15 A18 A25 = 3 MHz = 6 MHz = 15 MHz = 18 MHz = 25 MHz (Example) DOWNLINK OUTPUT POWER 01 02 03 04 ENCLOSURE STYLE T3 = Painted = 1 Watt = 2 Watt = 10 Watt = 10 Watt Table 1: Series 62 signal booster models. TX RX Systems Inc. Manual 7-9470-1.1 04/27/09 Page 1 Uplink In Downlink Out Downlink In Uplink Out Figure 1A: Front view of the Series 62 signal booster. Fuse ON / OFF Switch AC Cord Connects Here Figure 1B: Rear view of the Series 62 signal booster. TX RX Systems Inc. Manual 7-9470-1.1 04/27/09 Page 2 path configuration with sharp out of band attenuation assuring isolation between the receiving and transmitting paths. A front and rear view of the unit are shown in Figures 1A and 1B respectively. Electrical, mechanical, and environmental specifications are listed in Table 2. UNPACKING It is important to report any visible damage to the carrier immediately. It is the customer’s responsibility to file damage claims with the carrier within a short period of time after delivery (1 to 5 days). Care should be taken when removing the unit from the packing box to avoid damage to the unit. Use caution because the heat sink fins can have somewhat sharp corners. BLOCK DIAGRAM DESCRIPTION The Series 62 single-band signal booster is a broadband, bidirectional, dual branch (uplink and downlink) system. Linear RF active amplifiers, filters, and DC power sources are used to adequately boost and re-radiate the passband signals. Signal flow through the system is illustrated using the system interconnect diagram shown in Figure 2. The signal booster system is composed of two symmetrical branches, uplink and downlink. The only difference between the two branches is the tuning of their duplexer passbands. The duplexers isolate the uplink and downlink paths from each others allowing common connectors to be used for Electrical Specifications Passband Gain 80 dB Min (at max output power) 50 db Min (at min output power) Manual Attenuation Range 0 to 30 dB in 2 dB steps Passband Ripple +/- 1.5 dB (typical) Noise Figure 5 dB Max (at 25°C and max gain) 3rd Order Output Intercept Point Uplink +40 dBm Min Downlink +52 dBm Min Input / Output Impedance 50 ohms Nominal Input / Output VSWR 1.5 : 1.0 (max) Input Power 80 to 240 VAC at 50 / 60 Hz Signal Test Ports Optional -50 dB sample signal / additional BNC ports Alarm Capability Optional Form-C contacts (DB-9 connector) Mechanical Specifications Paint Gray Powder-Coat Dimensions 15.0” x 14.6” x 8.1” (381 mm x 371 mm x 206 mm) RF Connectors N-type Female Weight 30 lBs. (13.63 kg) Environmental Conditions This unit is designed for indoor applications Operating Temperature -30 to +50 °C Table 2: Series 62 signal booster specifications. TX RX Systems Inc. Manual 7-9470-1.1 04/27/09 Page 3 RF In UL Front RF Out End Module RF In UL Power RF Amplifier Out Module TX Duplexer To Uplink Antenna RX Power Entry Front Panel Module AC Power Supply RX Duplexer To Downlink Antenna TX RF In DL Front RF Out End Module DL Power RF RF In Amplifier Out Module Figure 2: System interconnect diagram. both input and output signals. The downlink path receives RF signals from the base station and amplifies and transmits them to the subscriber. The uplink path receives RF signals from the subscriber and amplifies and transmits them to the base station. FRONT-END MODULE The block diagram for the Front-End Module is shown in Figure 3. Received RF signals leave the duplexer and are routed to the Front-End Module which provides amplification, variable attenuation, and filtering. U3 is the first stage of amplification on the Front-End Module and is an LNA with ultra-low noise figure and high linearity. Following the first stage LNA is a Digital Attenuator U4. The positive control inputs for this device are provided by the user adjustable rotary dip switch located on the front panel module. The rotary switch allows the user to adjust system gain for the uplink and downlink paths individually during the installation of the booster. TX RX Systems Inc. Manual 7-9470-1.1 The next functional device on the front-end module is the voltage variable attenuator U5. The control v o l t a g e fo r t h i s a t t e n u a t o r i s d e s i g n a t e d “VVA_CTL” and its source is the RF Detector circuit on the power amplifier module. The detector circuit produces an analog voltage proportional to the RF signal strength. This is an OLC (Output Level Control) feedback which is incorporated into the systems design for output power limiting and to minimize intermodulation products from excessively strong input signal levels. The OLC circuitry located on the power amplifier module senses the output power and automatically limits it by adjusting the variable attenuator U5. An LED located on the front panel module for both the uplink and downlink channels will illuminate whenever output power meets or exceeds the OLC factory preset level for that channel. The next amplifier stage U1 following the variable attenuator is a broadband design that incorporates low noise as well as high IP3. The output from the amplifier is passed thru the low pass filter FL1 which provides harmonic rejection. Further amplifi- 04/27/09 Page 4 UL Front End Module 3-22620 3.3V 5VA RF IN 5VB 5VC RF OUT RF Atten U4 Amp A U3 Volt Var Atten U5 Amp B U1 Amp C U2 FL1 FL2 V V A Control Atten Control U9 3.3V Reg 5VA 5VB 5VC Reg Temp Sense U11 U6 U7 U10 Curr Sense U8 Temp Curr 9V Ribbon Cable to Front Panel Module Figure 3: Front-End Module block diagram. Uplink shown as an example. cation and filtering is provided by amplifier U2 and low pass filter FL2. RF signals then exit the FrontEnd module at the RF output connector and are applied to the Power Amplifier Module. The front-end module also contains a Temperature Sensing and Current Sensing circuit, U11 and U8 respectively. These circuits are used to detect an excessive temperature or current draw condition. The output from the sensors are fed back to the Microcontroller on the Front Panel Module and are used to determine an alarm condition. There are four voltage regulators on the Front-End Module (U9, U6, U7, and U10) which are used to create bias voltages from the 9 VDC source voltage supplied to the module through the ribbon cable. POWER AMPLIFIER MODULE The block diagram for the Power Amplifier Module is shown in Figure 4. The first stage of the Power Amplifier Module is the driver amplifier U2. This is a medium power high linearity amplifier which serves as a preamp for the high power amplifier. U4 is the final output high power amplifier. This is an integrated multi-stage power amplifier with onchip impedance matching. The output of the power TX RX Systems Inc. Manual 7-9470-1.1 amplifier is applied to the directional coupler U3 which is used to sample the OLC feedback signal. RF signals leave the Power Amplifier Module at the RF output connector and are then applied to a duplexer which routes the signals to the appropriate antenna. The power amplifier module also contains a Temperature sensing circuit U1 and two Current sensing circuits U8 and U9 for the driver amplifier and power amplifier respectively. These circuits are used to detect an excessive temperature or current draw condition. The output from the sensors are fed back to the Microcontroller on the Front Panel Module and used to determine an alarm condition. In addition, the temperature sensor and PA current sensor are used by the on-board Microcontroller U7 to turn off the power amplifier via the “PA OFF” control signal. This will protect the power amplifier under conditions of excessive current draw or temperature. There are two voltage regulators on the Front-End Module (U10 and U11) which are used to create bias voltages from the 28 VDC source voltage supplied to the module through the ribbon cable. The regulator U10 is the source of the 9 VDC used by the front-end module. A malfunction 04/27/09 Page 5 UL Power Amplifier Module 3-22621 5V 9V RF IN Driver U2 PA U4 PA Off -20dB Temp Sense U1 Curr Sense U8 RF OUT Directional Coupler U3 Curr Sense U9 RF Det U5 PIC U7 OLC Adj 30dB Pad -50dB Port U6 V V A Control 5V 9V PA Off PA Temp PA Curr Driver Curr Reg U10 9V Reg U11 28V Ribbon Cable to Front Panel Module Figure 4: Power Amplifier Module block diagram. Uplink shown as an example. of regulator U11 on the power amplifier module will shut down the front-end module. FRONT PANEL MODULE The block diagram for the Front Panel Module is shown in Figure 5. The Microcontroller U1 monitors the temperature and current control inputs from the front-end and power amplifier modules and will respond with an alarm whenever a control line is active. During an alarm the micro will illuminate the appropriate alarm LED (uplink or downlink). The uplink and downlink “VVA_CTL” control signal is passed through the front panel module via ribbon cable J1 and J2. The microcontroller monitors these control lines and illuminates either the uplink or downlink OLC LED whenever the respective signal is active. The OLC LED will remain lit while output leveling is taking place. The Output Level Control (OLC) allows for output power limiting. A variable step attenuator gives 0 to 30 dB of attenuation in 2 dB steps. The use of these controls are covered in the “OPERATION” section, later in this document. TX RX Systems Inc. Manual 7-9470-1.1 Voltage regulator U10 is used to create bias voltages from the 9 VDC source voltage supplied to the module through the ribbon cable. The power amplifier module is the source of the 9 VDC used by the front panel module. So a malfunction of regulator U11 on the power amplifier module will shut down the front panel module. There are two user adjustable rotary switches located on the front panel module, S1 for uplink and S2 for downlink. The rotary switch allows the user to adjust system gain for the uplink and downlink paths individually during the installation of the booster. POWER ENTRY/SUPPLY The booster is designed to operate between 80 and 240 VAC. Figure 6 shows the block diagram for the Power Entry Module as well as the Power Supply. The power entry module has a dual pole switch for the incoming AC which is followed by a pair of inline fuses. When operating the booster at 110 VAC one fuse can be replaced by a jumper. Operation at 220 VAC will require both fuses to be used. RF interference is reduced by the EMI filtering. The power supply is a switching design that will operate at either 110 or 220 VAC and is programmed by jumpers. There is a green LED on the 04/27/09 Page 6 To UL Front-End Front Panel Module 3-22636 UL DIP Gain Adj SW U10 5V J4 To UL Power Amp S1 28V Reg UL Temp UL Curr UL PA Temp UL PA Curr UL Driver Curr 5V UL UL DL DL OLC ALM OLC ALM PIC U1 DL Driver Curr DL PA Curr DL PA Temp DL Curr DL Temp PRG Pwr 28VDC DL DIP Gain Adj SW J7 9V V V A Crl J2 J1 V V A Crl 9V 28V S2 To DL Power Amp J5 To DL Front-End Figure 5: Front Panel Module block diagram. supply which is illuminated whenever the supply is on. The output of the supply is 28 VDC which is applied to J7 on the front panel module. CONNECTIONS AC power is accepted through a standard 3-wire male plug (IEC-320) with phase, neutral and ground leads. The AC power is wired to a high efficiency DC switching power supply which is CE and UL approved. The power supply runs all of the modules within the cabinet and the Power On LED on the front panel module. This LED provides an indication to the user that the system is powered. The metal enclosure of the signal booster is connected to ground. RF connections are made via two type “N” female connectors. The RF connector labeled “Uplink Out Power Entry Module 80-240VAC EMI Filter 80-240VAC Switching Power Supply 28VDC To Front Panel Module Figure 6: Power Entry / Supply. TX RX Systems Inc. Manual 7-9470-1.1 04/27/09 Page 7 / Downlink In” must be connected to the antenna pointing towards the base station. The RF connection labeled “Uplink In / Downlink Out” must be connected to the antenna facing the area to be covered by the signal booster. RF connections must be made through cables with characteristic impedance of 50 ohms. Isolation between the two antennas should be at least 15 dB higher than the signal booster gain. Isolation less than this value can cause gain ripple across the band. Isolation equal to or less than the signal booster gain will give rise to oscillations which will saturate the amplifiers and possibly cause damage to the signal booster. Normally Open, Common, and Normally Closed relay contacts are available at pins 1, 2, and 3 respectively of the DB9 connector. Refer to the pinout diagram in figure 7. In a Non-Alarm condition there will be continuity between the Normally Open and Common pins. During an Alarm condition continuity will switch to the Common and Normally Closed pins. INSTALLATION The following sub-sections of the manual discuss general considerations for installing the booster. All work should be performed by qualified personnel in accordance with local codes. Location The layout of the signal distribution system will be the prime factor in determining the mounting location of this unit. However safety and serviceability are also key considerations. The unit should be located where it can not be tampered with by the general public, yet is easily accessible to service personnel. Also, consider the weight of the unit and the possibility for injur y if it should become detached from its mounting surface for any reason. GND N.O. COM. N.C. ALARMS CONDITIONS The alarm circuit monitors the current and temperature of both the Uplink and Downlink amplifiers. An alarm condition will occur if either the Uplink or Downlink amplifiers are over or under their current tolerance. The respective front panel alarm LED will blink to indicate the alarm condition. An OLC over-range error which causes the booster to shut down for 10 minutes will be indicated by a continuousely illuminated alarm LED. An option is available for the booster that allows remote alarm sensing through a DB-9 connector which is added to the back of the unit in the lower right. Customers should connect their remote alarm sensing cables to this plug. Refer to Figure 7. 1 2 3 4 5 +12V(250mA) 6 7 8 9 Figure 7: Remote alarm sensing connector. TX RX Systems Inc. Manual 7-9470-1.1 04/27/09 Page 8 15.000 13.750 POWER 7.250 OLC 28 30 0 ALARM 26 OLC 28 30 0 26 24 22 10 ALARM 24 22 10 20 18 16 14 12 20 18 16 14 12 GAIN REDUCTION GAIN REDUCTION 0 . . . 30 dB 0 . . . 30 dB 0.750 15.437 0.531 14.624 3.062 3.062 DOWNLINK IN UPLINK OUT UPLINK IN DOWNLINK OUT 8.075 5.201 Figure 8: Mechanical dimensions. The signal booster uses external heat sinks and needs to be mounted such that there can be unobstructed air flow over the heat sink fins. The cabinet will stay warm during normal operation so in the interest of equipment longevity, avoid locations that carry hot exhaust air or are continually hot. Mounting Figure 8 shows mounting hole dimensions and layout for the cabinet. Because TX RX Systems, Inc. cannot anticipate all the possible mounting locations and structure types where these devices TX RX Systems Inc. Manual 7-9470-1.1 will be located, we recommend consulting local building inspectors, engineering consultants or architects for advice on how to properly mount objects of this type, size and weight in your particular situation. It is the customers responsibility to make sure these devices are mounted safely and in compliance with local building codes. Antenna Isolation Antenna isolation between uplink and downlink should be measured before connecting the signal booster to the antenna system. This step is neces- 04/27/09 Page 9 MEASUREMENT PROCEDURE To measure the antenna isolation perform the following in a step-by-step fashion. sary to insure that no conditions exist that could possibly damage the signal booster and should not be skipped for even the most thoroughly designed system. 1) Set the signal generator for a 0 dBm output level at the center frequency of one of the boosters passbands. Just like the feedback squeal that can occur when the microphone and speaker get too close together in a public address system, a signal booster can start to self oscillate. This can occur when the isolation between the Uplink and Downlink antennas does not exceed the signal boosters gain by at least 15 dB. Oscillation will reduce the effectiveness of the system and may possibly damage amplifier stages. Isolation values are relatively easy to measure with a spectrum analyzer and signal generator. 2) Set the spectrum analyzer for the same center frequency and a sweep width equal to or just slightly greater than the passband chosen earlier in step 1. 3) Temporarily connect the test leads of the signal generator and spectrum analyzer together using a female barrel connector, see Figure 9. Observe the signal on the analyzer and adjust the input attenuator of the spectrum analyzer for a signal level that just reaches the 0 dBm level at the top of the graticule. REQUIRED EQUIPMENT The following equipment is required in order to perform the antenna isolation measurements. 4) Referring to figure 9, connect the generator test lead to one side of the antenna system and the spectrum analyzer to the other then observe the signal level. The difference between this observed level and 0 dBm is the isolation between the sections. If the signal is too weak to observe, the spectrum analyzer’s bandwidth may have to be narrowed and its input attenuation reduced. The isolation value measured 1) Signal generator for the frequencies of interest capable of a 0 dBm output level. Modulation is not necessary. 2) Spectrum analyzer that covers the frequencies of interest and is capable of observing signal levels down to -100 dBm or better. 3) Double shielded coaxial test cables made from RG142, RG55 or RG223 coaxial cable. External Antenna (YAGI) Internal Signal Distribution System (Omni-directional Antennas) Signal Generator Isolation (dB) Zero Loss Reference Spectrum Analyzer Figure 9: Typical test equipment interconnection for measuring antenna isolation. TX RX Systems Inc. Manual 7-9470-1.1 04/27/09 Page 10 should exceed the signal booster’s gain figure by at least 15 dB. 5) Repeat step 4 again with the signal generator set to frequencies at the passbands edges in order to see if the isolation is remaining relatively constant over the complete width of the passband. 6) Repeat the isolation measurements at the other system passbands to determine the overall minimum isolation value for the system. Physical modification of the antenna system maybe required in order to reach an acceptable minimum value. Installation Procedure To install the signal booster perform the following in a step-by-step fashion. CAUTION: DO NOT APPLY A.C. P OW E R TO T H E S I G N A L BOOSTER UNTIL CABLES ARE CONNECTED TO BOTH PORTS OF THE SIGNAL BOOSTER AND THE ANTENNAS. 1. Mount the signal booster on the wall with the RF connectors pointing DOWN. Using appropriate screws and anchors, attach the signal booster to the wall at the six mounting holes on the side flanges. Refer to figure 8. 2. Ensure that the isolation between the donor antenna and the service antenna is at least 15 dB greater than the signal booster gain. (Use the higher of the Uplink and Downlink gains reported on the test data sheet). 3. Connect the cable from the donor antenna to the signal booster connector labeled “Uplink Out / Downlink In” and the cable from the service antennas to the signal booster connector labeled “Downlink Out / Uplink In”. 4. Review the attenuator positions on the front of the signal booster and verify that both of the attenuator’s are positioned to their maximum setting (30 dB). 5. Connect the AC power cord to the signal booster and then to the power source. Move the ON/ OFF switch to the ON position and verify that the “Power ON” LED is illuminated. TX RX Systems Inc. Manual 7-9470-1.1 Installation of the signal booster is now complete. To adjust the gain controls to suit the specific signal environment, refer to the next section of the manual. NOTE For repeat installations of existing equipment, make sure the attenuation setting is positioned to its maximum setting (30 dB). After verification of the attenuation, follow the above steps starting with step 1. OPERATION Power is applied to the unit by turning ON the AC power switch located on the upper rear of the cabinet. The front panel Power Indicator LED should illuminate. Refer to Figure 10 which is a view of the front panel. Variable Step Attenuator The signal booster gain can be reduced by up to 30 dB in 2 dB steps using the variable step attenuator. Gain adjustments are made with rotar y switches on the front of the unit. The attenuators are labeled for Uplink and Downlink. Arrows on the shafts of these switches point to the value of attenuation selected. Gain can be determined by subtracting the attenuation value from the gain reported on the Test Data Sheet for that side of the unit. A small screwdriver should be used for making attenuator adjustments. OLC (Output Level Control) To minimize inter modulation products, each branch in the signal booster contains an OLC feedback loop. The OLC circuit senses the output power and limits it to a factory preset level on the Uplink and the Downlink. Red indicator LEDs located on the front panel for both the uplink and downlink will illuminate when output power meets or exceeds the OLC factory preset level. To establish proper operating gain on the Uplink and Downlink sides, star t with the Downlink. Observe the downlink OLC indicator LED. Units are shipped with maximum attenuation. Decrease the downlink variable attenuator one step at a time until the downlink OLC lamp is lit. Then increase the step attenuation until the lamp goes off. Repeat the process for the Uplink. The OLC indicator LED is accurate to within +/- 0.4 dB of the OLC factory preset level. 04/27/09 Page 11 Power ON LED Downlink OLC Uplink Alarm Uplink OLC Downlink Alarm Rotary Attenuator Rotary Attenuator Figure 10: The Front Panel. CAUTION: Operation of the signal booster at maximum gain with greater than -20 dBm average power incident on either of the RF Input connectors can cause damage to the signal booster. RF EXPOSURE In order to satisfy the FCC RF exposure requirements, the signal booster/antenna installation must comply with the following: The outdoor antenna (Yagi type or similar directional antenna) must be installed so as to provide a minimum separation distance of 1.0 Meters (100 cm or 40 inches) between the antenna and persons within the area. (This assumes a typical antenna with gain of 10.1 dBi, VSWR < or = 1.5 : 1, Zo= 50 ohms, and a cable attenuation of between 1-10 dB). The indoor antenna (omni directional) must be installed so as to provide a minimum separation distance of 0.4 Meters (40 cm or 16 inches) between the antenna and persons within the area. (This assumes a typical wide-beam type antenna with gain of 0-2 dBi, VSWR < or = 2 : 1, Zo= 50 ohms, and a cable attenuation of between 1-10 dB). DIAGNOSTIC GUIDE The signal booster provides long term, care-free operation and requires no periodic maintenance. There are no user-serviceable components inside the signal booster. This section covers possible problems that may be related to the installation or operating environment. TX RX Systems Inc. Manual 7-9470-1.1 Gain Reduction Possible causes: bad RF cables, bad RF connections to antennas or damaged antennas. Excessive Intermodulation or Spurious Possible causes: Amplifier oscillation caused by insufficient isolation. The isolation between two antennas is given by the equation: Isolation = 92.5 + 20 Log (F x D) – Gt – Gr F = frequency (GHz) Gt = transmit antenna gain (in the direction of the receive antenna) D = separation (Km) Gr = receive antenna gain (in the direction of the transmit antenna) For example, at the SMR frequencies, the antenna isolation at 100 m separation is about 71 dB for omni-directional antennas (0 dB gain). To increase isolation, the antennas should have higher directivity and must be pointed away from each other. Occasional Drop-out of Some Channels Possible causes: One channel with very strong power dominates the RF output of the amplifier. Optional Sampler Ports An option is available for the booster that brings the -50 db sampler ports on the power amplifier assembly out to the side panel near the RF connectors. This option provides a convenience for technicians installing or ser vicing the signal booster. 04/27/09 Page 12 Return Loss vs. VSWR Watts to dBm Return Loss VSWR Watts dBm 30 1.06 300 54.8 25 1.11 250 54.0 20 1.20 200 53.0 19 1.25 150 51.8 18 1.28 100 50.0 17 1.33 75 48.8 16 1.37 50 47.0 15 1.43 25 44.0 14 1.50 20 43.0 13 1.57 15 41.8 12 1.67 10 40.0 11 1.78 37.0 10 1.92 36.0 2.10 34.8 33.0 30.0 dBm = 10log P/1mW Where P = power (Watt) Insertion Loss Insertion Loss Input Power (Watts) 50 75 100 125 150 200 250 300 25 38 50 63 75 100 125 150 2.5 28 42 56 70 84 112 141 169 32 47 63 79 95 126 158 189 1.5 35 53 71 88 106 142 177 212 40 60 79 99 119 159 199 238 .5 45 67 89 111 134 178 223 267 Output Power (Watts) Free Space Loss Frequency (MHz) Distance (miles) .25 .50 .75 10 15 150 68 74 78 80 86 94 100 104 220 71 77 81 83 89 97 103 107 460 78 84 87 90 96 104 110 113 860 83 89 93 95 101 109 115 119 940 84 90 94 96 102 110 116 120 1920 90 96 100 102 108 116 122 126 Free Space Loss (dB) Free space loss = 36.6 + 20log D + 20log F Where D = distance in miles and F = frequency in MHz TX RX Systems Inc. Manual 7-9470-1.1 04/27/09 Page 13 SYSTEMS INC. RX Systems Manual 14 TX RX TX Systems Inc. 8625Inc. Industrial Parkway, Angola, NY7-9470-1.1 14006 Tel: 716-549-4700 Fax: 04/27/09 716-549-4772 sales@txrx.com Page www.txrx.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 20 Page Mode : UseThumbs Page Layout : SinglePage XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:b5765e1d-914e-417e-8a4b-1c65b7ea9063 Modify Date : 2009:04:29 13:24:12-04:00 Create Date : 2009:04:29 13:18:27-04:00 Metadata Date : 2009:04:29 13:24:12-04:00 Document ID : uuid:7bc98f7c-b130-49f0-a0cf-ef851061385b Format : application/pdf Creator : FrameMaker 6.0 Producer : Acrobat Distiller 6.0.1 (Windows)EXIF Metadata provided by EXIF.tools