Bosch Security Systems ATX-CR-RV Allplex track User Manual ALLPLEX track Coordinator

Bosch Security Systems, Inc. Allplex track ALLPLEX track Coordinator

Contents

Users Manual

 Engineered Solutions | ALLPLEX track CoordinatorALLPLEX track Coordinator www.boschsecurity.com             uDevice controller for up to 15 receiversuPowered using Power over Ethernet (PoE)uWired TCP/IP to the host central consoleuWired (RS-485) or wireless communication toreceiveruSelectable frequencies of 303.825 / 304 / 433.42MHzuRemote firmware upgradable via wired TCP/IPuBuilt-in 2 inputs and 2 relay outputsThe ALLPLEX track coordinator is a device controllerfor up to 15 ALLPLEX track receivers. Its primaryfunction is to monitor the receivers, and reportconditions and events to the central console overwired Ethernet (TCP/IP). The coordinator can bepowered using Power over Ethernet (PoE).FunctionsFunction during alarm• When a receiver detects an alarm, it goes into anOff‑Normal state. To quickly locate any devices whichmight be in the Off‑Normal State, the coordinatorissues global commands that are interpretedsimultaneously by all of its devices approximately tentimes per second.• The coordinator sends commands to specific devicesto determine the nature of the Off‑Normal condition.During an alarm or test, the coordinator sendscommands to obtain the transmitter identificationnumber, transmitter battery condition, and receivedsignal strength.• The alarm information is sent by the receiver to thecoordinator either by wired RS-485 or throughwireless radio frequency.• The alarm information is then relayed by thecoordinator to the central console by wired Ethernet(TCP/IP), where it graphically shows the identity andlocation of the subscriber (user) sending the alarm.ConfigurationThe coordinator identifies each receiver by its address.The address is set during system installation using aDIP switch on the receiver circuit board. Coordinatorscommunicate on the data bus with individual devicesby issuing commands, which contain the receiver’saddress.Setup and testingUpon setting up each coordinator and connecteddevices, they can be tested remotely from the centralconsole. Also, each coordinator reports any problems,such as low battery, immediately upon detecting them.Alarm input and relay output controlThe coordinator has two analog inputs and two relayoutputs. The analog inputs are monitored and support4 state supervised modes. The coordinator can detectshort/open wiring conditions, and initiate an alarm ifthe appropriate input devices are connected. Eachrelay output provisions for normally open (NO),normally closed (NC) and common (C) terminals.
Certifications and approvalsThe product is classified in accordance with thefollowing standards:• FCC part 15.231• ETSI EN300 (433.42 Mhz)• RCMInstallation/configuration notesInstallationThe coordinator is for indoor and outdoor use. Thecoordinator mounts in one of two different sizedenclosures. Connect the receivers to the coordinatorusing one 3‑wire multiplex buses: two wires for data(A and B) and one wire for GND. Each bus supports 1built-in receiver of the coordinator and up to 15external receivers. A Security Escort System supportsup to 1024 coordinators and a total of 16384 devices.Mounting ConsiderationsYou will need a Security Hex Driver to mount thereceiver.•Indoor Enclosure: Mount on inside walls.•Outdoor Enclosure: Mount on the sides of buildingsand on light posts.Compatibility InformationCentral ConsoleSoftwareSE3000 SeriesAT receiver ATX-RCV-MT01AT transmitter ATX-TRM-304T01, ATX-TRM-433T01Transmitter SE2 Series, SE3 Series, SE3401 and SE88SeriesParts includedQuantity Component1ALLPLEX track Coordinator1 ALLPLEX track Coordinator & Receiver Installation Manual4 2.2 kΩ Axial Lead ResistorsTechnical specificationsTransmissionFrequency 303.825 / 304 (default) / 433.42 MHzselectable by Dip SwitchTrouble Output Signal sent through the central consoleAntenna Type InternalSensitivityAdjustments-100 dB minimumElectricalPower Consumption 200mA @ +12VDC (max)Operating InputVoltage10.8 – 13.2VPrimary PowerSourcePower over Ethernet (PoE)(PoE standard: IEEE 802.3af-2003 and IEEE802.3at-2009 Type 1)Secondary PowerSource12V DC inEnvironmentalOperatingTemperature-30°C to +65°C(-22°F to +149°F)HardwareInput 2 analog inputs(4 state supervised monitoring)Output 2 relay outputs(Relay dry contact, 1A @ 30V DC)CommunicationInterfaceEthernet 10/100 BaseT (central console)RS-485 / Wireless radio frequency (receivers)Housing Tamper Normally closed (NC)ReliabilityMean Time BetweenFailures (MTBF)10 yearsOrdering informationALLPLEX track CoordinatorControls ALLPLEX track receivers. Relays alarm andtest signals from the receivers to the central console.Selectable frequencies of 303.825 / 304 / 433.42 MHzby dip switch.Order number ATX-COR-MT01 2 | ALLPLEX track Coordinator
3 | ALLPLEX track CoordinatorRepresented by:Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 9180security.sales@us.bosch.comwww.boschsecurity.usBosch Security Systems B.V.P.O. Box 800025617 BA Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 330emea.securitysystems@bosch.comwww.boschsecurity.comRobert Bosch (SEA) Pte Ltd, SecuritySystems11 Bishan Street 21Singapore 573943Phone: +65 6571 2808Fax: +65 6571 2699apr.securitysystems@bosch.comwww.boschsecurity.asiaBosch (Shanghai) Security Systems Ltd.201 Building, No. 333 Fuquan RoadNorth IBPChangning District, Shanghai200335 ChinaPhone +86 21 22181111Fax: +86 21 22182398www.boschsecurity.com.cnRobert Bosch Ltda Security Systems DivisionVia Anhanguera, Km 98CEP 13065-900Campinas, Sao Paulo, BrazilPhone: +55 19 2103 2860Fax: +55 19 2103 2862latam.boschsecurity@bosch.comwww.boschsecurity.com© Bosch Security Systems 2014 | Data subject to change without notice8008436747 | en, V1, 17. Jul 2014

Navigation menu