Cambium Networks 45700 Wireless Ethernet Bridge, Dual Channel OFDM MIMO Combination Point to Point / Point to Multipoint Equipment User Manual PTP700 Series User Guide
Cambium Networks Limited Wireless Ethernet Bridge, Dual Channel OFDM MIMO Combination Point to Point / Point to Multipoint Equipment PTP700 Series User Guide
Contents
User Guide Part 3





















![Chapter 6: Configuration and alignment Installation menu Warning When installing the PTP 700 ATEX/HAZLOC product variants in hazardous locations, follow the instructions contained in the PTP 700 Series Hazardous Location Guide (supplied in box with the products), in addition to the instructions in this user guide. Caution The lower center frequency attribute must be configured to the same value for both the Master and Slave, otherwise the wireless link will fail to establish. The only way to recover from this situation is to modify the Lower Center Frequency attributes so that they are identical on both the master and slave units. Note When configuring a linked pair of units, use the Master Slave Mode to ensure that one unit is Master and the other is Slave. Table 118 Wireless Configuration attributes Attribute Meaning Master Slave Mode Master: The unit controls the point-to-point link and its maintenance. On startup, the Master transmits until a link with the Slave is made. Slave: The unit listens for its peer and only transmits when the peer has been identified. Access Method ODUs must be configured in pairs before a link can be established. Access Method determines how paired ODUs will recognize each other. Link Access: Each ODU must be configured with Target MAC Address equal to the MAC Address of the other unit. Link Name Access: Both ODUs must be configured with the same Link Name. Group Access: Only displayed when a Group Access license key has been generated (Generating license keys on page 6-3) and submitted (Software License Key page on page 6-11). Both ODUs must be configured with the same Group ID attributes. Target MAC Address Only displayed when Access Method is set to Link Access. This is the MAC Address of the peer unit that will be at the other end of the wireless link. This is used by the system to ensure the unit establishes a wireless link to the correct peer. The MAC Address can be found embedded within the serial number of the unit. The last six characters of the serial number are the last three bytes of the unit’s MAC address. Link Name Only displayed when Access Method is set to Link Name Access. Link Name may consist of letters (A-Z and a-z), numbers (0-9), spaces, and the following special characters: (),-.,:<=>[]_{} Link Name must be same at both ends and different to site name. Group Id Only displayed when Access Method is set to Group Access. A link can only be established between units that have identical Group IDs. Page 6-22](https://usermanual.wiki/Cambium-Networks/45700.User-Guide-Part-3/User-Guide-2678547-Page-22.png)








![Chapter 6: Configuration and alignment System menu Figure 136 Mute Transmitter control in System Configuration page Caution Configuring link encryption over an operational link will necessitate a service outage. Therefore, the configuration process should be scheduled during a period of low link utilization. Procedure: • If AES encryption is required but the System Configuration page does not contain the Encryption Algorithm or Encryption Key attributes, then order the necessary AES capability upgrade, generate a license key and enter it on the Software License Key page (Software License Key page on page 6-11). • Update the attributes (Table 120). • To save changes, click Submit Updated System Configuration. • If a reboot request is displayed, click Reboot Wireless Unit and OK to confirm. Table 120 System Configuration attributes Attribute Meaning Transmitter Only displayed when the ODU is a Master unit and Transmitter Mute Control is enabled. Use the Mute Transmitter control to toggle between Muted and Enabled. Muted: The ODU will not radiate and will not forward Ethernet frames between the wireless interface and the Ethernet ports. Enabled: The ODU is allowed by the user to radiate and will forward Ethernet frames between the wireless interface and the Ethernet ports. Link Name Link Name may consist of letters (A-Z and a-z), numbers (0-9), spaces, and the following special characters: (),-.,:<=>[]_{}. Link Name must be same at both ends and different to site name. Site Name User defined name for the site, with additional notes (if required). Latitude The latitude of the ODU, measured in decimal degrees. This attribute has no internal function. Longitude The longitude of the ODU, measured in decimal degrees. This attribute has no internal function. Altitude The altitude of the ODU, measured in meters. This attribute has no internal function. Page 6-31](https://usermanual.wiki/Cambium-Networks/45700.User-Guide-Part-3/User-Guide-2678547-Page-31.png)