Collis SMARTWAVEBOX Inductive Proximity Card Reader User Manual SmartWave user manual CE FCC 1 0

Collis B.V. Inductive Proximity Card Reader SmartWave user manual CE FCC 1 0

Contents

User manual part 2

Download: Collis SMARTWAVEBOX Inductive Proximity Card Reader User Manual SmartWave user manual CE FCC 1 0
Mirror Download [FCC.gov]Collis SMARTWAVEBOX Inductive Proximity Card Reader User Manual SmartWave user manual CE FCC 1 0
Document ID1151790
Application IDiZHdyPlSOGRCN9Yaoc9/kA==
Document DescriptionUser manual part 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize149.2kB (1865026 bits)
Date Submitted2009-08-11 00:00:00
Date Available2009-08-11 00:00:00
Creation Date2009-07-07 19:49:53
Producing SoftwareGPL Ghostscript 8.64
Document Lastmod2009-07-22 14:36:42
Document TitleSmartWave_user_manual_CE_FCC_1.0
Document CreatorPDFCreator Version 0.9.8
Document Author: ni

SmartWave Box
User Manual
External Tx data
Trigger output
Transmit data
Positive pulse, 1 µs, on selected trigger
Analog output levels, like RF and demodulated RF, are 0 – 3.3 Volt.
Digital outputs inverting buffer ports, 0 – 3.3 Volt.
Fig. 2 Front panel of the SmartWave box
The test connectors are MCX female PCB-mounted connectors.
Note: Check section 7.1 Technical for other detail technical data.
5.4 Terminal / Card side
The SmartWave Box has an internal terminal to communicate with CL cards and a CL card
emulator probe for communication with the CL terminal.
Both the internal terminal and the CL probe support ISO 14443 Type A and B and ISO 18092
NFCIP-1.
The CL probe is connected by a cable with the SmartWave Box, using a 6 pin FireWire
connector at the backpanel of the box.
All communications with CUT and / or TUT are performed with nominal values for magnetic
field strength and modulation depths, since reliable tests with other values require a, per test,
calibration of these values. Tests of ISO 14443/2 will not be performed with the SmartWave
Box, although the SmartWave Box facilitates these measurements with the analog RF output
connectors.
5.5 Modes of operation
The SmartWave Box has the following modes of operation:
• Analyzer mode
• Interceptor mode
• Card reader mode
• Card emulator mode
• Passive spying mode
5.5.1
Analyzer mode
The CL CUT and the TUT are connected via the SmartWave Box. The SmartWave Box will
resupply the RF signal driver. In addition I/O direction information, CL card power level (if
supplied by the card) and timestamps are transferred to the driver.
The I/O and I/O direction information is output to high impedance connectors on the front of
the SmartWave Box (Different output can be configured through API).
Power levels if available are relative otherwise it requires calibration for each test and test setup
with a known (external) reference.
Status: Final draft
6/12
Version: 1.0
SmartWave Box
User Manual
5.5.2
Interceptor mode
The interceptor mode looks the same as the Analyzer mode; however the I/O data is not
directly moved between the CUT and the TUT. The data from CL card or the terminal is sent to
the host computer which will send the same or modified data to the terminal or the CL card.
Due to timing constraints the level 3 anti-collision is performed directly by card and terminal
without host intervention, however all frames are passed to the host. After that the level 4
transfers are routed via the host computer.
5.5.3
Card reader mode
In the card reader mode the SmartWave Box acts as an intelligent CL card reader. This enables
tests with various bit rates and modulation types.
This mode can be used to perform the tests as described in ISO 10373-6 Amd.1 and ISO 23917,
apart of the level 2 tests.
5.5.4
Card emulator mode
In the card emulator mode only the CL probe is used and directly controlled by the host
computer.
This mode can be used to perform the tests as described in ISO 10373-6 Amd.3 and ISO 23917,
apart from level 2 tests.
Status: Final draft
7/12
Version: 1.0
SmartWave Box
User Manual
5.5.5
Passive spy mode
The card spying mode uses a passive pick-up coil to capture communication between a CL card
and a terminal. Neither the CL card nor the terminal needs to be connected with the host
computer. Care is taken to influence the CL card – terminal communication a less as possible.
Note: The passive spy mode is only available with v02.00+ hardware; active spy will be used
on v01.xx boxes.
With active spy, it works using the setup like analyse mode, while the box only forwards the
raw signal between CUT and TUT instead of transmitting bytes.
Status: Final draft
8/12
Version: 1.0
SmartWave Box
User Manual
COMMUNICATING WITH THE SMARTWAVE BOX
The SmartWave Box is command driven. The host computer configures the SmartWave Box
and will either passively capture data or actively interact with CL card or terminal.
The frame transfer is of a request – response type, where the host computer sends the requests
and the SmartWave Box sends the response.
For some events the SmartWave Box sends unsolicited messages.
6.1 Host interface protocol
The host computer – SmartWave Box protocol is TLV (Tag, Length, Value) based, this allows
easy adaptations in the future.
Every message, both from the host or from the SmartWave Box, starts with a 2 byte start frame
delimiter (SFD) and ends with an end frame delimiter (EFD). The 1st byte of the SFD = 0xF3,
the 2nd byte 0xA0, the 1st byte of the EFD = 0x0E, the 2nd byte 0xFD.
A command message can contain a number of TLV structures, the responses also contain more
than one TLV, see below.
SFD
Tag0 Len0 Value0 Tag1 Len1 Value1
TagN
LenN ValueN
EFD
To ease processing by 16-bit word based processors, all fields have an even length. The basic
structure of a TLV field is shown below:
Length
Name
Description
Tag
The Tag signals value type
Length
This field shows the length of the following value (always even)
0 - 65534 Value
The field contains the relevant data.
NB.
If the length field equals 00 00, the value field is not available.
When the data in the value field has an odd length, that length has to given in the Len field and
Value field is padded with a zero byte, resulting in an even Value field length. So when 7 bytes
of data (11 22 33 44 55 66 77) have to be transferred, the message will be as follows:
SFD
F3 A0
Tag
00 xx
Length
00 07
Value
11 22 33 44 55 66 77
Padding
00
EFD
0E FD
When the length of the value field exceeds 65534, the value field is split in 2 parts; the 1st part
with a length of 65534 and a 2nd part containing the rest with an ‘extended data’ tag.
For example a frame with a length of 6600 0 bytes (0x101D0) to be sent to the TUT will be
transferred as follow (al hex values):
SFD
F3 A0
Tag
00 21
Length Value
Tag ext.
FF FE Data (part 1) 00 80
Status: Final draft
9/12
Length Value
01 D2 Data (rest)
EFD
0E FD
Version: 1.0
SmartWave Box
User Manual
6.2 Tag types
The following Tag fields are defined:
Name
Box control command
Box info command
Box control response
Box info response
Box event
Box trigger timestamp
Terminal transmit TPDU
Probe transmit TPDU
Connect
Error control
Received antenna TPDU
Received probe TPDU
Connection status
Timestamp
Status
Terminal download data
Probe download data
Terminal register dump
Probe register dump
Write PLL data
Write DAC data
Download data status
Extended data
Value
(hex)
00 00
00 01
00 10
00 11
00 15
00 16
00 20
00 21
00 23
00 25
00 30
00 31
00 33
00 35
00 36
00 40
00 41
00 42
00 43
00 48
00 49
00 50
00 80
Description
Commands to the SmartWave Box
Get SmartWave Box information
Response of Box control command
Response of Box info command
Unsolicited event from box
Unsolicited timestamp event of trigger moment
TPDU data to internal terminal (to be sent to CUT)
TPDU data to CL probe (to be sent to TUT)
Start connection with CUT and / or TUT
Error injection control
TPDU data from internal terminal (received from CUT)
TPDU data received from CL probe (received from TUT)
Status of connection command
Timestamps connected to received data
Status of received data
Data loaded for terminal emulation
Data loaded for card emulation
Terminal RF chip register dump (debug only)
Probe RF chip register dump (debug only)
Write data to PLL (debug only)
Write data to DAC (debug only)
Status of data loaded for terminal or card emulation
Last part of data field with more than 65534 bytes
(This tag must directly follow the 1st data part)
Source and destination addressing is implicit and depends on the tag value. Tags destined for
the SmartWave Box have an even high nibble for the low byte, responses have odd high nibbles
of the low bytes (apart from tag 00 80).
Some messages from the host only allow for one type of tag, other messages allow a number of
specified tags.
Single tag type messages only can have a single tag = 00 00, 00 01, 00 23, 00 40 and 00 41
(hex).
Multiple tag messages can have the following combinations:
- tag = 00 20 followed by 00 80 and / or 00 25 (hex)
- tag = 00 21 followed by 00 80 and / or 00 25 (hex)
Tag 00 25 can’t be the first tag in a message.
Messages from the SmartWave Box with tags of 00 10, 00 11, 00 15, 00 16, 00 33 and 00 50
(hex) are single tag messages, tag 00 01 only may occur once in a message.
Tags 00 10 and 00 11 are response messages for respectively 00 00 and 00 01.
Status: Final draft
10/12
Version: 1.0
SmartWave Box
User Manual
Tag 00 33 is the response of tag 00 23.
Tag 00 50 is the response status for either 00 40 or 00 41 command tags.
Messages starting with 00 30 or 00 31 (hex) are multiple tag messages and can be followed by
tags 00 80, 00 35 and / or 00 36 (hex).
The SmartWave Box only reacts on messages starting with tag values 00 00, 00 01, 00 20, 00
21, 00 23, 00 40or 00 41, other tag values are quietly discarded.
The data transfers between host and SmartWave Box are Transport Protocol Data Unit (TPDU)
based. That allows the transfer of level 3 and 4 frames. For level 4 also Application Protocol
Data Units (APDUs) are defined. APDUs to the SmartWave Box must translated by the host
into TPDUs and back.
Note:
Checksums, like LRC and CRC, have to be supplied by the host computer. The
checksum coming from the SmartWave Box have to be checked by the host computer.
In case of higher level tests the SmartWave Box can connect automatically with the card or
terminal under test if commanded to. That allows level 4 testing without need for level 3
handling.
Note: Check the technical specification of the SmartWave Box for detail host protocol
information.
Status: Final draft
11/12
Version: 1.0
SmartWave Box
User Manual
APPENDIX
7.1 Technical Information
Power consumption
Power adapter
Working frequency
USB
max 5.5W
18V/840mA
13.56Mhz
2.0
Physical dimensions (LxWx(H1-H2))
Temperature
166.5x126x(34-43)
+55°C (max)
(equipment for normal indoor use)
Weight
Sound
373g
Transducer
Probe dimension: (LxWxH)
Probe weight:
189x58x12
39g
Analog output levels (e.g. -INTERN- ANT): 0 – 3.3 Volt (max).
Digital outputs level(s): 0 – 3.3 Volt.
7.2 CE/FCC Statement
CE
This equipment has been tested and found to comply with the limits of the European Council
Directive on the approximation of the member states relating to electromagnetic compatibility.
(98/336/EEC) according to EN 55022 Class B.
FCC
Warning (part 15.21)
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this
transmitter should only be used or installed at locations where there is at least 20cm
separation distance between the antenna and all persons.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
Status: Final draft
12/12
Version: 1.0
SmartWave Box
User Manual
SUPPORT
For troubleshooting, support or more information contact Collis BV
E-mail
Telephone
: service@collis.nl
: + 31 71 581 3636
Status: Final draft
13/12
Version: 1.0
SmartWave Box
User Manual
REFERENCES
Ref.
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
Title
ISO 7816/3
Smart Card standard,
electrical signals and transmission protocols
ISO 7816/4
Smart Card standard,
interindustry commands for interchange
ISO 14443/2 CL card standard – proximity cards,
RF interface power and signal interface
(+ Amendment 1)
ISO 14443/3 CL card standard – proximity cards,
initialization and anticollision.
(+ Amendments 1 and 3)
ISO 14443/4 CL card standard – proximity cards,
transmission protocol
(+ Amendment 1)
ISO 18092
Near Field Communication cards,
interface and protocol
ISO 10273-6 Identification cards, test methods
proximity cards
ISO 10273-6 Amendment 1
Protocol test methods for proximity cards
ISO 10273-6 Amendment 3
Protocol test methods for proximity coupling devices
ISO 10273-6 Amendment 5
Bit rates of fc/64, fc/32 and fc/16
ISO 23917
NFCIP-1 protocol test methods
SmartWave Box requirement specification document
SmartWave Box Technical Specification
Status: Final draft
14/12
Status
Version
Date
1997
1995
2001
2005
2001
2005/2006
2001
2006
2004
2001
1.1
2005
29-06-2006
Final
draft
Final
draft
Final
draft
Final
Version: 1.0

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : ni
Create Date                     : 2009:07:07 19:49:53+02:00
Modify Date                     : 2009:07:22 14:36:42+02:00
Subject                         : 
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : GPL Ghostscript 8.64
Keywords                        : 
Creator Tool                    : PDFCreator Version 0.9.8
Metadata Date                   : 2009:07:22 14:36:42+02:00
Document ID                     : 1ee2d982-6d7a-11de-0000-8af2565baf58
Instance ID                     : uuid:a58e80ff-1ae8-4de1-b920-ec3063a20e50
Format                          : application/pdf
Title                           : SmartWave_user_manual_CE_FCC_1.0
Creator                         : ni
Description                     : 
Description (x-repair)          : 
Page Count                      : 9
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XKD-SMARTWAVEBOX

Navigation menu