Controlled Electronic Management Systems S700PXV1-00 S700 multi smart card reader User Manual S700 Quick Guide

Controlled Electronic Management Systems Ltd S700 multi smart card reader S700 Quick Guide

Contents

Quick start guide

Download: Controlled Electronic Management Systems S700PXV1-00 S700 multi smart card reader User Manual S700 Quick Guide
Mirror Download [FCC.gov]Controlled Electronic Management Systems S700PXV1-00 S700 multi smart card reader User Manual S700 Quick Guide
Document ID3321336
Application IDCJglzQfsBH/irVJQIUcoEg==
Document DescriptionQuick start guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize134.19kB (1677437 bits)
Date Submitted2017-03-17 00:00:00
Date Available2017-03-17 00:00:00
Creation Date2017-02-15 11:28:18
Producing SoftwareGPL Ghostscript 9.06
Document Lastmod2017-02-15 11:28:18
Document TitleS700_Quick Guide.pdf
Document CreatorAdobe Acrobat 10.1.10
Document Author: tiharrison

(3)INTERLOCK
0V
1. Using the drilled mounting holes, screw the back
casing to the back box.
2. Screw the I/O board to the back casing, ensuring to
replace the spacers.
3. Connect the internal speaker to the I/O board. The
yellow speaker wires can be wired to the J6 speaker
terminal in any order.
0V
SUPPLY INPUT
J9
NO C NC GND NO C NC 0V SUPPLY
INPUT
RELAY 2
RELAY 1
DO NOT connect a
power supply to this
terminal.
The terminal labelled DC
OUTPUT can ONLY be
used as an output to
power other devices,
such as exit readers and
third-party Wiegand
readheads.
DC Output
MORTICE
LOCK
J9
NO C NC GND NO C NC 0V SUPPLY
INPUT
RELAY 1
RELAY 2
Fail-secure Lock
In fail-secure configuration, if the terminal loses
power, the lock remains closed. A lock that requires
power to open, such as a mortice lock, must be
used.
MAGNETIC LOCK
ANT 1
RLY 1
RLY 2
J7
J10
SW1
S700e Reader
NO C NC GND NO C NC 0V SUPPLY
INPUT
RELAY 1
RELAY 2
J9
0V
(0) DOOR POS
D16
D17
J4
SUPPLY INPUT
12V-24V DC NOM.
@2.5A MAX.
DC OUTPUT
12V @ 1A MAX.
RELAY
24V DC MAX.
@2A MAX.
J6
0V
SUPPLY INPUT
Mounting the back casing to the back box
1B
1A
0V
DC OUTPUT
RS485 2B
RS485 2A
0V
SUPPLY INPUT
RS232 TX
RS232 RX
0V
SPEAKER
SPEAKER
0V
J2
WIE
RLY 1
0V
(0) DOOR POS
MAGNETIC LOCK
0V
REQUEST
TO EXIT
(1) LOCK POS
LABEL
0V
(2)REX
0V
Fail-safe Lock
If the terminal loses power, a fail-safe lock opens
allowing free access. Therefore, a lock that is
constantly powered, such as a maglock, must be
used.
LOCK
SENSE
J7
(3)INTERLOCK
J3
RS485
HOST
1B
1A
0V
DC OUTPUT
RS485 2B
RS485 2A
Head
WIEGAND
DC OUTPUT
LED RED
LED GREEN
LED AMBER
0V
D1
D0
SOUNDER
INPUT
LABEL
J3
J9
J7
GAND
INPUTS
EXIT/DIU
HOST
RS485
RLY 2
PSU 12V (2.5A)
or 24V (1.25A)
S700s Reader
J10
SUPPLY INPUT
12V-24V DC NOM.
@2.5A MAX.
DC OUTPUT
12V @ 1A MAX.
RELAY
24V DC MAX.
@2A MAX.
J6 0V
SUPPLY INPUT
RS232 TX
RS232 RX
0V
SPEAKER
SPEAKER
0V
J2
NO C NC GND NO C NC 0V SUPPLY
INPUT
RELAY 1
RELAY 2
(1) LOCK POS
Wiegand
Third-Party
DOOR
POSITION
0V
J2
RS485
HOST
0V
(2)REX
0V
J3
EXIT/DIU
(3)INTERLOCK
J7
WIEGAND
DC OUTPUT
LED RED
LED GREEN
LED AMBER
0V
D1
D0
SOUNDER
INPUT
Third-Party Wiegand Readhead
EXIT/DIU
Ensure that the correct card definition for the chosen card technology is loaded on
the CDC.
Card definitions
If inputs are used to trigger alarms or events in AC2000 AED they must first be configured
in the AC2000 Devices application. For more information, see AC2000 Setup Guide.
Configuring device inputs
Open AC2000 | Device Configuration | Devices.
In the left pane, expand the Controller to which the terminal is being added.
Right-click the appropriate Device Group and select Add Device.
From the Device Type drop-down list, select the S700 model to install.
From the Configuration Mode drop-down list select the setting that matches
your hardware setup.
6. From the Device Number drop-down list select a device number.
7. Enter a unique description for the device in Device Location .
8. Enter the MAC Address of the device. To display the MAC Address
on the terminal select System Information | Network.
9. Enter the IP address of the device.
10. Click Add to complete the setup.
1.
2.
3.
4.
5.
Adding the device to AC2000
Wiring Configuration: S700e Host + S700s Exit
WIRING NOTES
3a
IP65
-20 to +70 (-4 °F to +158 °F)
Operating temperature (°C)
IP rating
24 Vdc @ 2 A
10/100 Base-T TCP/IP CAT6 / RS485 serial comms
Dry contacts output
RS485 serial comms / Wiegand protocol
Comms to system host
2.5 mm
3.0 mm
Software Setup
DC OUTPUT
LED RED
LED GREEN
LED AMBER
0V
D1
D0
SOUNDER
1. Remove the four screws and spacers using a Pozi head screwdriver.
2. Remove the two yellow internal speaker wires from connector J6 on
the I/O board.
3. Lift the I/O board away from the back casing.
4. Drill the cable access holes using the guides on the back casing.
5. Drill the holes on the terminal casing to match the back box fixture points.
1. Set the terminal on a level surface.
2. Remove the four screws using
a hex security screwdriver.
3. Remove the front part of the
terminal, pivoting at the base.
4. Disconnect the ribbon cable from
the I/O board.
Opening the terminal
Mounting the Terminal
Flat head screwdriver
Flat head screwdriver
Four analogue inputs - voltage supplied
Typcial: 2.4 / Peak: 4.8
9 to 28
Rating
Size H20
Size PZ1
Comms to exit reader
Inputs
Power (W)
Supply Voltage (Vdc)
Part
Required tools
Hex security screwdriver
Pozi head screwdriver
0V
SUPPLY INPUT
Removing the I/O board
For a complete description of the S700 and its
features, refer to the Technical Product Specification
at: http://www.cemsys.com/S700
This guide contains the basic instructions for installing
the S700 intelligent access terminal.
Quick Installation Guide
S700e
TM
Specifications
1B
1A
0V
DC OUTPUT
RS485 2B
RS485 2A
(1) LOCK POS
0V
(0) DOOR POS
J7
J10
SW1
NO C NC GND NO C NC 0V
RELAY 1
RELAY 2
D16
D17
J4
Cancel
Delete
LOCK
SENSE
DOOR
POSITION
255.255.255.0
0.0.0.0
Subnet mask
Gateway
Change
172.16.42.6
IP address
HOST
RS485
RLY 2
J1
RDR +12
485A
485B
COM
GPO J2
COM
REX
DOOR
COM
LOCK
J5
LNK 2
LNK 3
LNK 4
LNK 5
BUZZ +
BGU
COM
J4 J3
FIRE
TAMPER
BUZZ –
J9
BUZZ +
BGU
COM
FIRE
TAMPER
BUZZ –
- PSU 12V
+ 2A min
- MAGNETIC
LOCK
TAMPER
FIRE
BGU
BUZZ +
BGU
COM
FIRE
TAMPER
BUZZ –
Terminal is connected to network using ethernet
The terminal is now connected to the AC2000 system and ready to use.
Present Card
Terminal is connected
to the RTC
Terminal has received
configuration settings
from the CDC
Checking network status
The network status is continuously displayed on the home screen of the reader.
Terminal has received the onboard database
5. Select Change to edit the selected field.
6. Enter the IP Address, Subnet and Gateway settings using the keypad. Press the left
function key for a '.'
7. To exit settings, press key 0 and select Save to save the new settings, or Quit to
discard changes.
BUZZ +
BGU
COM
FIRE
TAMPER
BUZZ –
connections on J9 must be linked out.
NOTE: On the DIU, if BGU, FIRE or TAMPER are not used the
J8 LOCK –
LOCK +
COM
MAINS FAIL
LOCKIN 12V/24V
SUPPLY 12V
DIU200
Note: Power is supplied by the DIU
J10
SUPPLY INPUT
12V-24V DC NOM.
@2.5A MAX.
DC OUTPUT
12V @ 1A MAX.
RELAY
24V DC MAX.
@2A MAX.
J6 0V
SUPPLY INPUT
RS232 TX
RS232 RX
0V
SPEAKER
SPEAKER
0V
J2
S700s Reader
S700: Network settings
Next
J9
2. Enter the pass code 67670000 to access the Config Menu. After the AC2000 system
setup is complete, the pass code is 6767XXXX, where XXXX is the code set by the system
administrator in Device Configuration.
3. To access the Network Settings menu, press key 5.
4. Select Next to highlight the relevant field.
CEM SYSTEMS
Enter Setup PIN
J3
EXIT/DIU
NO C NC GND NO C NC 0V SUPPLY
INPUT
RELAY 1
RELAY 2
REQUEST
TO EXIT
RLY 1
1. On the terminal keypad, quickly tap the right function key at least three times.
Setting the terminal IP address, Subnet mask and Gateway
Configuring the Network
ANT 1
0V
(2)REX
0V
RLY 1
SUPPLY INPUT
J6
0V
J9
0V
0V
(0) DOOR POS
SUPPLY INPUT
12V-24V DC NOM.
@2.5A MAX.
DC OUTPUT
RLY 2 12V @ 1A MAX.
RELAY
SUPPLY
24V DC MAX.
INPUT
@2A MAX.
(3)INTERLOCK
LABEL
1B
1A
0V
DC OUTPUT
RS485 2B
RS485 2A
LABEL
0V
(2)REX
0V
0V
SUPPLY INPUT
RS232 TX
RS232 RX
0V
SPEAKER
SPEAKER
0V
(1) LOCK POS
J7
WIEGAND
INPUTS
0V
J2
RS485
HOST
(3)INTERLOCK
J3
EXIT/DIU
DC OUTPUT
LED RED
LED GREEN
LED AMBER
0V
D1
D0
SOUNDER
J7
WIEGAND
DC OUTPUT
LED RED
LED GREEN
LED AMBER
0V
D1
D0
SOUNDER
INPUT
Wiring Configuration: S700e + DIU200 + S700s
0V
SUPPLY INPUT
3b
1B
1A
0V
DC OUTPUT
RS485 2B
RS485 2A
4. Clip the side panels onto each side of
the terminal covering each of the
mounting screws.
Tel: +44 (0)28 90 456656
Equipment changes or modifications without the approval of the party responsible for compliance could void the
user's authority to operate the equipment and could create a hazardous condition.
This system must be installed within the protected premsie in accordance with the National Electrical Code
(NFPA70), and the local authorities having jurisdiction.
Installation of this device shall be performed by a qualified person in accordance to all local regulations.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End
users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter
must not be collocated or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept an interference received, including interference that may cause undesired operation.
WARNING - For FCC labelled S700 Terminals
S700-IG-0087-1.72
Copyright © 2016 Controlled Electronic Management Systems Limited. All rights reserved.
No part of this publication may be produced without the written permission of CEM Systems Limited.
Safety and Regulatory Information
Technical Support
cem.sales@tycoint.com
http:www.cemsys.com/S700
http:www.cemsys.com/support
http:www.cemsys.com/support
Sales
Datasheets
Installation Manual
User Guide
For more information on the S700, consult the following resources.
Support
3. Screw the front casing to the back
casing using the four security hex
screws.
2. Ensure the large case o ring and the 4
small o rings are in place. Attach the
front case to back case.
Care should be taken when re-assembling the terminal. The front case
should not be left hanging from the ribbon cable while attached to the
back case. Ensure there is adequate network cable length to reach
the connectors.
Re-assembling the Terminal
1. Connect the ribbon cable to the
I/O board.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:5900fb9c-f5cd-11e6-0000-73f1a5d0729d
Producer                        : GPL Ghostscript 9.06
Modify Date                     : 2017:02:15 11:28:18Z
Create Date                     : 2017:02:15 11:28:18Z
Creator Tool                    : Adobe Acrobat 10.1.10
Document ID                     : uuid:5900fb9c-f5cd-11e6-0000-73f1a5d0729d
Format                          : application/pdf
Title                           : S700_Quick Guide.pdf
Creator                         : tiharrison
Author                          : tiharrison
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QABS700PXV1-00

Navigation menu