Controlled Electronic Management Systems S700PXV1-00 S700 multi smart card reader User Manual S700 Quick Guide

Controlled Electronic Management Systems Ltd S700 multi smart card reader S700 Quick Guide

Contents

Quick start guide

!Required toolsSpecificationsThis guide contains the basic instructions for installing the S700 intelligent access terminal.For a complete description of the S700 and its features, refer to the Technical Product Specification at: http://www.cemsys.com/S700Hex security screwdriver   Size H20Pozi head screwdriver    Size PZ19 to 28Four analogue inputs - voltage suppliedTypcial: 2.4 / Peak: 4.8RS485 serial comms / Wiegand protocol10/100 Base-T TCP/IP CAT6 / RS485 serial comms24 Vdc @ 2 A -20 to +70 (-4 °F to +158 °F)Operating temperature  (°C)Dry contacts outputComms to system hostComms to exit readerInputsPower (W)Supply Voltage (Vdc)Part Rating                           IP65IP rating2.5 mm3.0 mmFlat head screwdriver Flat head screwdriver Adding the device to AC2000Configuring device inputsCard definitions1.    Open AC2000 | Device Configuration | Devices.2.    In the left pane, expand the Controller to which the terminal is being added.3.    Right-click the appropriate Device Group and select Add Device.4.    From the Device Type drop-down list, select the S700 model to install. 5.    From the Configuration Mode drop-down list select the setting that matches  your hardware setup.6.    From the Device Number drop-down list select a device number. 7.    Enter a unique description for the device in Device Location .8.    Enter the MAC Address of the device. To display the MAC Address   on the terminal select System Information | Network.9.    Enter the IP address of the device.10.  Click Add to complete the setup.If inputs are used to trigger alarms or events in AC2000 AED they must first be configured in the AC2000 Devices application. For more information, see AC2000 Setup Guide.Ensure that the correct card definition for the chosen card technology is loaded on the CDC.2Mounting the Terminal1. Remove the four screws and spacers using a Pozi head screwdriver.2. Remove the two yellow internal speaker wires from connector J6 on the I/O board.3. Lift the I/O board away from the back casing.4. Drill the cable access holes using the guides on the back casing.5. Drill the holes on the terminal casing to match the back box fixture points.Opening the terminal1. Set the terminal on a level surface.2. Remove the four screws using    a hex security screwdriver.3. Remove the front part of the      terminal, pivoting at the base. 4. Disconnect the ribbon cable from   the I/O board.Removing the I/O board Mounting the back casing to the back box1. Using the drilled mounting holes, screw the back     casing to the back box.2. Screw the I/O board to the back casing, ensuring to     replace the spacers.3. Connect the internal speaker to the I/O board. The       yellow speaker wires can be wired to the J6 speaker     terminal in any order. GND 0V SUPPLYINPUTNORELAY 1C NC NORELAY 2CNC0V0V0VSPEAKERSPEAKERSUPPLY INPUTRS232 TXRS232 RX0V0V(0) DOOR POS(1) LOCK POS0VSUPPLY INPUT0V(3)INTERLOCK0V(2)REXDC OUTPUT0VSOUNDERD1D0LED REDLED GREENLED AMBER0VRS485 2ADC OUTPUTRS485 2B1BRS485INPUT WIEGAND EXIT/DIU HOST1ARLY 2RLY 1LABELJ3 J7 J2J6J9J10RELAY24V DC MAX.@2A MAX.SUPPLY INPUT12V-24V DC NOM.@2.5A MAX.DC OUTPUT12V @ 1A MAX.D17D16J4J7DOORPOSITIONLOCKSENSEREQUESTTO EXIT-+MAGNETICLOCKPSU 12V (2.5A)or 24V (1.25A)-+GND0VSUPPLYINPUTNORELAY 1CNCNORELAY 2CNC0V0V0VSPEAKERSPEAKERSUPPLY INPUTRS232 TXRS232 RXRLY 2RLY 1LABEL0V0V(0) DOOR POS(1) LOCK POS(1) LOCK POS0V(3)INTERLOCK0V(2)REXDC OUTPUT0VSOUNDERD1D0LED REDLED GREENLED AMBER(1) LOCK POSJ3J7J6J9J10RELAY24V DC MAX.@2A MAX.SUPPLY INPUT12V-24V DC NOM.@2.5A MAX.DC OUTPUT12V @ 1A MAX.WIE                                                                    GANDWIE                                                                    GANDWIE                                                                    GANDWIE                                                                    GANDINPUTSEXIT/DIU HOSTSUPPLY INPUT0V0VRS485 2ADC OUTPUTRS485 2B1B1AJ2RS485SW1ANT 1S700s ReaderS700e ReaderWiring Configuration: S700e Host + S700s Exit3aIn fail-secure configuration, if the terminal loses power, the lock remains closed. A lock that requires power to open, such as a mortice lock, must be used.Fail-secure Lock If the terminal loses power, a fail-safe lock opens allowing free access. Therefore, a lock that is constantly powered, such as a maglock, must be used.Fail-safe Lock DC Output Third-Party Wiegand Readhead   GND 0V SUPPLYINPUTNORELAY 1C NC NORELAY 2CNCJ9-+MAGNETICLOCK GND 0V SUPPLYINPUTNORELAY 1C NC NORELAY 2CNCJ9-+MORTICELOCKThe terminal labelled DC OUTPUT can ONLY be used as an output to power other devices, such as exit readers and third-party Wiegand readheads.DO NOT connect a power supply to this terminal.0VSUPPLY INPUTSUPPLY INPUT0V(3)INTERLOCKDC OUTPUT0VSOUNDERD1D0LED REDLED GREENLED AMBER0VRS485 2ADC OUTPUTRS485 2B1BRS485INPUTINPUTWIEGANDEXIT/DIUHOST1AJ3J7J2 Third-Party Wiegand Head WIRING NOTESQuick Installation Guide1Software SetupS700eTM
Wiring Configuration: S700e + DIU200 + S700s3bGND0VSUPPLYINPUTNORELAY 1CNCNORELAY 2CNC0V0V0VSPEAKERSPEAKERSUPPLY INPUTRS232 TXRS232 RXRLY 2RLY 1LABEL0V0V(0) DOOR POS(1) LOCK POS0V(3)INTERLOCK0V(2)REXDC OUTPUT0VSOUNDERD1D0LED REDLED GREENLED AMBER(1) LOCK POSJ3J7J6J9J10RELAY24V DC MAX.@2A MAX.SUPPLY INPUT12V-24V DC NOM.@2.5A MAX.DC OUTPUT12V @ 1A MAX.INPUTSWIEGANDEXIT/DIU HOSTS700s ReaderSUPPLY INPUT0V0VRS485 2ADC OUTPUTRS485 2B1B1AJ2RS485GND 0V SUPPLYINPUTNORELAY 1C NC NORELAY 2CNC0V0V0VSPEAKERSPEAKERSUPPLY INPUTRS232 TXRS232 RX0V0V(0) DOOR POS(1) LOCK POS 0VSUPPLY INPUT0V(3)INTERLOCK0V(2)REXDC OUTPUT0VSOUNDERD1D0LED REDLED GREENLED AMBER0VRS485 2ADC OUTPUTRS485 2B1BRS485INPUT WIEGAND EXIT/DIU HOST1ARLY 2RLY 1LABELJ3 J7 J2J6J9J10RELAY24V DC MAX.@2A MAX.SUPPLY INPUT12V-24V DC NOM.@2.5A MAX.DC OUTPUT12V @ 1A MAX.D17SW1ANT 1D16J4J7LNK 2 LNK 3 LNK 4LNK 51248J1J5GPOCOMREXDOORCOMLOCKJ9J8BGUCOMFIRETAMPERBUZZ –BUZZ +COM485A 485B RDR +12J2LOCK –COMMAINS FAILLOCKIN 12V/24VSUPPLY 12VLOCK +J4J3DIU200DOORPOSITIONLOCKSENSEREQUESTTO EXITNOTE: On the DIU, if BGU, FIRE or TAMPER are not used the connections on J9 must be linked out.BGUCOMFIRETAMPERBUZZ –BUZZ +BGUCOMFIRETAMPERBUZZ –BUZZ +BGUCOMFIRETAMPERBUZZ –BUZZ +FIREBGUTAMPERMAGNETICLOCK-+PSU 12V2A min-+Technical SupportTel: +44 (0)28 90 456656 Salescem.sales@tycoint.com1. On the terminal keypad, quickly tap the right function key at least three times.Setting the terminal IP address, Subnet mask and GatewayChecking network statusThe network status is continuously displayed on the home screen of the reader.             Terminal has received the onboard database Terminal has received configuration settings from the CDCTerminal is connected to network using ethernetTerminal is connected to the RTCConfiguring the Network5The terminal is now connected to the AC2000 system and ready to use.5. Select Change to edit the selected field.6. Enter the IP Address, Subnet and Gateway settings using the keypad. Press the left     function key for a '.'7. To exit settings, press key 0 and select Save to save the new settings, or Quit to     discard changes.!!WARNING  - For FCC labelled S700 TerminalsThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept an interference received, including interference that may cause undesired operation.This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Installation of this device shall be performed by a qualified person in accordance to all local regulations.This system  must be installed within the protected premsie in accordance with the National Electrical Code (NFPA70), and the local authorities having jurisdiction.Equipment changes or modifications without the approval of the party responsible for compliance could void the user's authority to operate the equipment and could create a hazardous condition.2. Enter the pass code 67670000 to access the Config Menu. After the AC2000 system    setup is complete, the pass code is 6767XXXX, where XXXX is the code set by the system    administrator in Device Configuration.3. To access the Network Settings menu, press key 5.4.  Select Next to highlight the relevant field.For more information on the S700, consult the following resources.Datasheets     http:www.cemsys.com/S700Installation Manual   http:www.cemsys.com/supportUser Guide     http:www.cemsys.com/supportSafety and Regulatory InformationSupportCopyright © 2016 Controlled Electronic Management Systems Limited. All rights reserved.No part of this publication may be produced without the written permission of CEM Systems Limited.4Re-assembling the TerminalCare should be taken when re-assembling the terminal. The front case should not be left hanging from the ribbon cable while attached to the back case. Ensure there is adequate network cable length to reach the  connectors.Note: Power is supplied by the DIU2. Ensure the large case o ring and the 4    small o rings are in place. Attach the        front case to back case.3. Screw the front casing to the back   casing using the four security hex     screws.  4. Clip the side panels onto each side of     the terminal covering each of the     mounting screws.1. Connect the ribbon cable to the       I/O board.Cancel DeleteEnter Setup PINNext ChangeS700: Network settingsIP addressSubnet maskGateway172.16.42.6255.255.255.00.0.0.0853CEM SYSTEMS1 2 34 5 67 809S700-IG-0087-1.72Present Card

Navigation menu