Delta Controls EM410R4 WIRELESS FIELD MODULE WITH 4 UIs, 1 AO AND 4 BOs User Manual
Delta Controls Inc. WIRELESS FIELD MODULE WITH 4 UIs, 1 AO AND 4 BOs Users Manual
Users Manual
Copyright © Delta Controls Printed 10/20/10 eM-410R4 enteliMESH Controller Installation Guide Product Description The eM-410R4 provides wireless remote I/O to a Wireless Coordinator. The controller has fixed algorithms that can be loaded in from the enteliTOUCH and configured to meet specific applications. The eM-410R4 also functions as a wireless repeater/router to extend the range of Delta enteliMESH devices. Specifications 24 VAC 8 VA, 50 VA maximum with fully loaded BO's Ambient Ratings 32° to 131°F (0° to 55°C) 10 to 90% RH (non condensing) Communication Ports ISM 2.4 GHz frequency band, wireless digital spread spectrum 802.15.4 compliant Technology 32-bit ARM processor Inputs 4 Universal inputs - 10 bit A/D (supporting 0-5v, 0-10v, 10kΩ, 4-20mA) Outputs 4 Binary Relay Outputs, 0.5 Amp @ 24VAC, jumper selectable for internal or external power, LED Power Power Consumption support.deltacontrols.com/.../EM410R4InstallGuide 1 of 6 Copyright © Delta Controls Printed 10/20/10 status indication 1 Analog Output (0-10 VDC) Compliance CE (ETSI) IC FCC, Class B, Part 15 Listings UL916 Listings and Compliance Declaration available for download at https://support.deltacontrols.com Package Contents • Product: eM-410R4 enteliMESH Controller • eM-410R4 Installation Guide Related Documents • enteliMESH Application Guide • ORCAview Technical Reference Guide • enteliTOUCH User Guide Cautions and Warnings This controller is an Electro-statically sensitive device. Proper ESD protection (ground strap) should be used when installing this product so that damage to the product does not occur. Equipment damage or loss of data may occur if these procedures are not followed as specified. Installations requiring CE conformance: All wiring for CE rated products must use an extra low voltage (SELV) or protective extra low voltage (PELV) transformer. Use safety-isolating transformers, (Class II transformer) per EN61558. The transformer must be rated for 100% duty cycle. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. (1) This device may not cause harmful interference and (2) This device must accept any interference received including interference that may cause undesired operation. FCC ID: YRR-eM410R4 IC ID: 9100A-eM410R4 Mounting and Dimensions The includes a plastic enclosure that can be quickly mounted with two screws (not provided). This controller should be mounted in an appropriate location within packaged equipment or another enclosure that meets code requirements. Dimension mm inches ±0.5 PCB width 100 PCB length 184 7 1/4 support.deltacontrols.com/.../EM410R4InstallGuide 2 of 6 Copyright © Delta Controls 101 46.5 1 7/8 191 7 1/2 204 217 8 1/2 24 12 1/2 Printed 10/20/10 Mounting wireless product inside a metal enclosure may reduce signal strength. An optional remote antenna can be used to extend the antenna and mount it externally on the enclosure. Board Layout eM-410R4 Layout Drawing Feature eM-410R4 Automatic Channel Selection Automatic PAN ID Selection Automatic Device Address Selection Battery Powered Hybrid Powered support.deltacontrols.com/.../EM410R4InstallGuide 3 of 6 Copyright © Delta Controls Printed 10/20/10 AC Powered Optional Antenna Mounting Routing Capable Inputs Outputs subPAN Capable Fixed Algorithm Power Wiring Most Delta Controls devices use a 24Vac Class 2, half wave rectified power supply (excluding DSM-050, ADM-2W704, which are FULL wave rectified). A single transformer may be used to power multiple controllers and/or auxiliary field devices (actuators, etc) provided the following conditions are met: • All devices MUST be half wave rectified. Mixing power between half wave and full wave rectified devices will damage both the transformer and connected equipment. • The transformer is properly sized, including line losses for the total VA requirements. • Polarity is observed between controllers (with respect to 24~ and Gnd). • The transformer secondary is fused for its maximum rated load (4A max for Class 2 circuits). General Wiring All wiring must conform to NEC and local codes and regulations. Use earth ground isolating step-down Class 2 transformers. Do not use autotransformers. Determine supply transformer rating by summing total VA of product and support.deltacontrols.com/.../EM410R4InstallGuide 4 of 6 Copyright © Delta Controls Printed 10/20/10 output loads. Risk of Electric Shock or Fire * More than one disconnect switch may be required to de-energize the equipment before servicing. * Do not interconnect the outputs of different Class 2 circuits. * All terminals are acceptable for Class 2 Circuit connections only * Use copper conductors only * Apply minimum 6.0 lb-in torque for tightening field wires into the terminal blocks Input and Output Configuration To connect input and output devices to this controller follow standard Delta Control wiring guidelines. Refer to separate documentation for additional details (Delta Wiring Guidelines). Input Configuration The input must be configured to accept the signal used by the input device. Place the jumper for each input in the correct location on the Input Type Selector Block. The diagram to the right shows the factory default selection of 10 KΩ. 4-20mA = For Sensors that use a 4 to 20 mA signal. 10K = for 10KΩ Thermistor temperature sensors, as well as Dry Contact binary inputs. 5V = for sensors that use a 0-5VDC signal 10V = for sensors that use a 0-10VDC signal Binary Output Configuration Binary Output Power Source: The relay outputs can be selected to use either an internal or external power source by placing the two jumpers in the correct locations. The diagram to the right shows the factory default selection of External Power Source. Internal 24 VAC Power is provided internally from within the board right to the output terminals. No external transformer is required. Note that the power supply should be sized appropriately to handle the additional loading. External Power needs to be provided externally to the board from a nearby transformer appropriately connected to the output wiring. The associated relay outputs are not “hot” contacts, except by means of the external transformer. Note The relays on this board are suitable for switching 24 VAC and 24 VDC. They are perfect for “dry contact” applications. support.deltacontrols.com/.../EM410R4InstallGuide 5 of 6 Copyright © Delta Controls Printed 10/20/10 Status Indicators LED RSSI (Received Signal Strength Indicator) Function LED Status Description Displays the received signal strength, communication status and controller troubleshooting. No communications - Solid Red Moderate communications - Solid Amber Good communications - Solid Green Join Status Join Status Indicator Solid green indicates that the controller is connected to the network. Solid red on startup indicates that the controller has not been joined to the network. Flashing green indicates that the controller has lost the network connection. Revision History EM410R4InstallGuide Rev:19: 2010-10-20T16:53:45 Include Files Revision data support.deltacontrols.com/.../EM410R4InstallGuide 6 of 6
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 6 Warning : Duplicate 'I52' entry in dictionary (ignored) Page Layout : SinglePage Page Mode : UseNone Producer : htmldoc 1.8.27 Copyright 1997-2006 Easy Software Products, All Rights Reserved. Create Date : 2010:10:20 16:57:01 Author : Main.RyanHughson, Copyright © 2010 Delta Controls Inc. All rights Reserved. Ideas, requests, problems regarding Delta Support? Send feedback Creator : Delta Support TWiki-4.1.2, Sat, 03 Mar 2007, build 13046 Subject :EXIF Metadata provided by EXIF.tools