Diversey R37615-00 Soap Dispenser with 900 MHz ISM User Manual Installation Guides
Diversey Inc Soap Dispenser with 900 MHz ISM Installation Guides
Diversey >
Installation Guides
UNITED STATES CANADA EUROPE 8215 Forest Point Blvd Charlotte NC 28273 USA Phone: t 1(980) 221-3236 www.sealedair.com Address: 3755 Laird Road Mississauga, Ontario L5L OB3 Canada Phone: t 1(905) 829-1200 www.sealedair.com Maarssenbroeksedijk 2 NL- 3542DN Utrecht The Netherlands Phone: t31 (0)30 247 6911 www.sealedair.com Sealed Air Diversey Care J> 91-00006_Rev2 1.1 DISPENSER INSTALLATION NOTES NOTE: SEE KEY DISPENSER DIMENSIONS BELOW (1.2). IF INSTALLING WITH DRIP CATCH OR ELBOW BAR, SEE CRmCAL DIMENSIONS BELOW (1.5 Drip·Catch and 2.2 Elbow Bar) 1. Remove key from back of housing. (Reference 'Key Location' in section 1.2, below) 2. The dispenser should be mounted 12 inches (30.5 em) above the counter-top, sink or other surface. 3. If replacing soap dispenser on wall, determine if any of the holes match up on the Sealed Air unit. Unit is designed to at least partially match numerous soap dispensers. 4. Mount the dispenser to wall using proper mounting hardware for your particular wall composition . Go to section 3.0 for specific dispenser mounting instructions. NOTE : TAPE & SCREWS/ANCHORS ARE PROVIDED FOR INSTALLATION. DISCLAIMER: If refills (Soap) used other than certified SA soap, SA is not responsible for any dispenser issues. 1.2 DIMENSIONS, KEY LOCATION, OPENING & CLOSING DISPENSER 1.3 REFILL PLACEMENT & REMOVAL **KEY OUTER DIMENSIONS OF DISPENSER : 1Hl10.24" 12fD'v1Ml x 1Wl6" I152.4MMJx IDI4'' [1 01.6mml • 'click' 6" {152.4mm) 10.24" {260mm) KEY LOCATION OPENING COVER CLOSING COVER Remove cover key {a) from back of housing. Insert key into holes on top of cover then pull cover forward. To close the cover, simply PUSH the top of cover closed to 'Click' shut {b). TO INSERT REFILL TO REMOVE REFILL Push refill into place to ensure the FLANGE of the Pull the Container {e) and the Pump Soap Nozzle {c) is seated into the correct location {d). Housing (f). Please recycle accordingly. If not, the dispenser will not pump correctly. 1.4 DOSE SIZE CONTROL GUIDE **To change dose setting, open dispenser cover and slide the red Dose Control Switch {a) to your desired dose size, 1.0 ML DOSE SETIING Ensure you slide the Control Switch {a) ALL the way to the left or right. SLIDE DOSE CONTROL SWITCH {a )TO THE LEFTFOR 1.0ML DOSE SETIING. SLIDE DOSE CONTROL SWITCH {a )TO THE RIGHT FOR 0.4ML DOSE SETIING. 1.5 OPTIONAL DRIP-CATCH INSTALLATION [ 409.22] 16.111 Insert drip catch hooks (a) through rectangular slots located at the backside of the dispenser. The Drip-Catch with SNAP into place. NOTE: The Drip Catch is not designed to be removed. However, if going to remove for cleaning please be careful not to damage the dispenser. The drip catch might be damaged after removing. DISCLAIMER: If other drip catch used, Sealed Air not responsible for damage. 0.4 ML DOSE SETIING no.4 no.S-1 no.7 no.S-2 QQ no.S-1 n0.1 Unlock and open Manual Dispenser cover n0.2 Remove Refill Bottle no.3 Use a drill with a 6mm bit to bore a hole in to the 2 pilot holes located on the inside left and right sides of the housing unit. n0. 4 Insert the Elbow Bar ends ( 4A) in to each of the holes from the outside . NOTE: COTTER RINGS (5·1 & 5·2) ARE OPTIONAL. (2A) (1 A). Insert Cotter Rings (SA) through Elbow Bar holes (58). no.S-2 Cotter Ring (SA) correctly installed close up view. from Dispenser. (3A) no.6 Lift up the elbow bar to a vertical position ( 6A). Re-install the Refill bottle ( 68) before closing the dispenser cover ( 6C). no.7 To comp lete the installation, lower the Elbow Bar (7 A) so that it rests in p lace on top o f the Push Lever. NOTE: To replace refill, you must LIFT up the Elbow Bar (similar to 6A) first, then UNLOCK and LOWER the COVER. After replacement of refill, CLOSE cover FIRST(GC) before lowering the Elbow Bar (7A). 2.2 ELBOW BAR- KEY DIMENSIONS MANUAL DISPENSER with ELBOW BAR FRONT VIEW KEY DIMENSIONS [ 171 10 ] 6.736 SIDE VIEW KEY DIMENSIONS _ [ 101.6 ] _ 4.0 SJJ1J 25 8.30 ] 10 .169 iZC=I\ ..1. [ 42.11 ] 1.658 /t=:!S}' Jl. r---- [ 141.38 ] _ __)===~=:d...J.~ f------ - 5._56_6_ [ 242.40 l - - - -----1 9.543 3.0 DISPENSER MOUNTING INSTRUCTIONS 1. Ensure the Key is removed from the housing. See Step 1 under 3.1 Below. 2. The dispenser should be mounted 12 inches (30.5 em) above the counter-top, sink or other surface. 3. If replacing soap dispenser on wall, determine if any of the holes match up on the Sealed Air unit. Unit is designed to at least partially match numerous soap dispensers. 4. Mount the dispenser to wall using proper mounting hardware for your particular wall composition . See 3.1 (Tape Mounting Instructions) and 3.2 (Screw Mounting Instructions) NOTE: Tape can be used effectively for installations on mirrors and tile. 3.1 TAPE MOUNTING INSTRUCTIONS STEP I STEP2 Step I: Ensure the back of the dispenser and the wall is properly cleaned for installation. Ensure that all surfaces are DRY before mounting the dispenser. STEP3 Step 2: Remove the white paper from the one side of the Tape (b). Place each piece of tape in the areas shown with the black dotted lines (c) Step 3: Once tape on the dispenser, remove the remaining red backing from both pieces of tape. Last, ensure that the dispenser is in a level position on the wall and press the dispenser firmly for 15 to 20 seconds to allow it to properly adhere to wall. NOTE : ENSURETHE KEY (a) IS REMOVED FROM HOUSING It's recommended to let the dispenser set up for 24 hours before installing the refill. 3.2 SCREW MOUNTING INSTRUCTIONS STEP I STEP2A STEP2B 1/4 (6.35mm) Drill Bit 0~-- Step I:The Dispenser housing Step 2A:Use a 1/4 (6.35mm) Step 2B:Insertanchors into provides numerous mounting drill bit to bore the holes on both holes. locations. If replacing a competitive the wall for the anchors and unit, determine if one (or more) screws provided. of the holes match. NOTE: Ensure that proper If no holes exist on wall or do not mounting hardware is used properly match, we suggest using for your particular the two holes circled above. wall composition. Step 3: Use a screwdriver to insert the screws in to the anchors and tighten the dispenser securely against the wall. 91-00006_Rev2 Soap Dispenser Placement Requirements and Recommendations (See dispenser instructions in dispenser package for actual dispenser installation) The following recommendations are intended to provide guidelines on best possible placement of handsoap dispensers. Because every location a dispenser is to be mounted is different, depending on customer site, physical size limitations, and available space, these recommendations may not always be entirely possible to follow. However, when placing a soap dispenser, the dispenser installation must meet ADA requirements and should promote ease of use and be in union with its surroundings. Upon installation, the dispenser should be level and the job results professional, presentable, and fully functional. Requirements for ADA Compliance: The dispenser must be operable with one hand. Minimum height requirements reference the height of the activator mechanism. o Maximum height is 48” when vanity is 20” (or less) deep. o Maximum height is 44” when vanity is 20”-25” deep. Restrooms Installation must be ADA compliant. Whenever possible, always mount the soap dispenser direct to a wall instead of a mirror or other installed fixture. o Always use screws to attach dispenser to wall when wall mounted. Anytime space is available, mount dispenser just to the left or right of a mirror. o Leave about 1/4" to 1/2" space between mirror and dispenser - just enough for it to open/shut freely and without obstruction. o IntelliCareTM Hybrid Dispenser’s must be mounted a minimum of 12 inches (30.5 cm) between the bottom of the dispenser and any horizontal surface to assure proper operation of the dispenser. (Be sure dispenser is still meeting ADA height requirements) When installing dispensers for sink modules with multiple wash basins, use good judgment when determining how many dispensers should be installed. A single dispenser should be sufficient in serving a module with two wash basins, while 2 dispensers should be sufficient to serve a module with 3 wash basins. o See enclosed examples for placement ideas. Install only on a mirror when all other possibilities have been exhausted. Food Service Areas It is recommended to always mount a soap dispenser direct to a wall instead of the sink’s backsplash whenever possible. o Always use screws to attach dispenser to wall when wall mounted. Anytime space is available, mount dispenser just to the left or right of the sink. o Leave about 1/4" to 1/2" space between sink and dispenser - just enough for it to open/shut without hitting the sink). o IntelliCareTM Hybrid Dispenser’s must be mounted a minimum of 12 inches (30.5 cm) between the bottom of the dispenser and any horizontal surface to assure proper operation of the dispenser. (Be sure dispenser is still meeting ADA height requirements) Avoid mounting a dispenser too high or too low. Always attempt to mount in close proximity of the actual use area. Do not install a hand soap dispenser directly above any surface where food will be prepared. In food service areas, a hand soap dispenser (and soap) is required at every hand wash sink. Install only on the sink backsplash when all other possibilities have been exhausted. Installation Examples for Restrooms Mirror Dispenser Wash Basin Single Sink (Family restroom) Double Sink Triple Sink Quadruple Sink Helpful Tip: Installing the dispenser in line with the bottom of the mirror (mounted over the lavatory) is always recommended. If the mirror is installed in compliance with ADA requirements (bottom of mirror max 40” above floor), the hand soap dispenser will be in ADA compliance. As well, this installation creates a cleaner sight line than other options. FCC Labeling Requirements This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. This device has been tested according to FCC RF Exposure guidelines and meets the applicable RF Exposure limits with all the intended use conditions for this device. ©Diversey, Inc 2017
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2016:06:16 14:59:49-05:00 Creator : Adobe Acrobat 10.1.13 Modify Date : 2017:12:05 12:23:14-05:00 Title : XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2017:12:05 12:23:14-05:00 Creator Tool : Adobe Acrobat 10.1.13 Format : application/pdf Document ID : uuid:03cffea5-bad5-4751-8d3f-bf9caeea3838 Instance ID : uuid:dfe8a1d6-89a6-458b-8606-b79b8ddb085a Producer : Adobe Acrobat 10.1.13 Paper Capture Plug-in Page Count : 8EXIF Metadata provided by EXIF.tools