Draeger Medical Systems MS18623 Telemetry Transceiver TeleSmart M300 User Manual TSC f80 en TUVdraft
Draeger Medical, Inc. Telemetry Transceiver TeleSmart M300 TSC f80 en TUVdraft
Contents
- 1. User Manual 1
- 2. User Manual 2
- 3. User Manual 3
- 4. User Manual 4
User Manual 3
12: Recordings / Reports Shift Report Cover Cursor time minus selected report length (2, 4, 8, 12, 24 hrs) Delay Recording Speed Patient information Each waveform contains 5 seconds of pre-event data and 5 seconds of real-time data. 12-14 TUV Draft Infinity CentralStation VF8 DRAFT Reports Patient Status The Patient Status section of the Shift Report is a summary report focusing on a patient's arrhythmia status. A Patient Status Report is also available as an independent report and can be configured to print 2, 4, 8, 12, or 24 hours of data (page 12-24). Header Information Heart Rate, calculated from trend data Pacemaker Bradycardia Ventricular Ectopics VF8 10 Supraventricular Ectopics Caliper Results S-T Deviation (from ST trends) Latest Alarm Event (in alarm categories) Comment area Infinity CentralStation TUV Draft 12-15 DRAFT 12: Recordings / Reports Graphical Trends In the Graphical Trends section of the Shift Report each parameter trend is plotted according to type. Parameter Type Appearance on Trend Graph Single-value, continuous such as HR Single, continuous line Single-value, intermittent such as C.O. Cross-hairs representing each value Multi-value, continuous such as ART Lines with a dotted line in the center indicating the mean value Multi-value, intermittent such as NBP Vertical line with a blank space in the center indicating the mean value e.g., The top and bottom line can represent systolic and diastolic values. This section resembles the full version Graphical Trend Report in appearance and content (page 12-18) but is numbered and labeled as part of the Shift Report. 12-16 TUV Draft Infinity CentralStation VF8 DRAFT Reports Selected Events Depending on how many events you select (page 14-16) the selected events section may consist of up to three pages (4 waveform strips each). You must select each event that will appear in this section of the shift report by clicking on the icon so that a check mark displays on the icon. Cursor time minus selected report length (2, 4, 8, 12, 24 hrs) Delay Recording speed The waveform contains 5 seconds of pre-event data and 5 seconds of real-time data. The event marks the middle of the waveform. Event Label Event Marker Example of an annotated event VF8 Infinity CentralStation TUV Draft 12-17 DRAFT 12: Recordings / Reports Graphical Trend Report The Graphical Trend Report is a multi-parameter report containing up to 15 trended parameters from bedside or telemetry patients. The report can be configured to print 2, 4, 8, 12, or 24 hours of Full or Event Disclosure data. The cursor time represents the report ‘stop time’; the report ‘start time’ equals ‘stop time’ minus the report length. You can customize the trend selection per patient (page 12-25) or at system setup (page 3-4). The trend scale can be a fixed scale or have autoscale values. When you select Enable Autoscale (page 12-25) in the Trend Order Setup screen, the low and high scale values are determined by an autoscale factor to the highest and lowest parameter value over the currently selected trend time. To request a Graphical Trend Report, see page 12-23. Parameter Autoscale Factor (approximate) HR PVC/min % Paced SpO2 PLS ST STVM STCVM Pressures (including NBP) 10 bpm 10 10% 10% 10 1.0 mm All others 0.10 mV 10 mmHg 1 kPa 10 Selected Strip Report The Selected Strip Report allows the user to select a waveform of interest within Full Disclosure and define beginning and ending cursor times (not to exceed one hour). The report can contain 8 seconds to 1 hour of information (8 second default) with 8 seconds of waveform data per row. To request this report, see page 12-24. Selected Events Report The Selected Events Report may consist of up to six pages (4 event strips per page). You can select and print the most recent 24 events. Each waveform contains 10 seconds of data, and is annotated with Lead Printed, Lead Processed, Event Cause, 12 of the most recent parameter values, Event End Time, and Event Date. If the lead processed is stored in the Infinity CentralStation database, it will be printed on the report. If not, the top lead of the displayed Full Disclosure data will appear.To request this report, see page 12-24. 12-18 TUV Draft Infinity CentralStation VF8 DRAFT
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Print high-res XMP Toolkit : 3.1-702 Modify Date : 2006:12:21 15:26:09+01:00 Create Date : 2006:12:21 14:31:12+01:00 Metadata Date : 2006:12:21 15:26:09+01:00 Creator Tool : FrameMaker 7.1 Format : application/pdf Title : TSC-f80-en(TUVdraft).book Creator : sullgr00 Document ID : uuid:3ae662da-3a3b-4138-957a-41176cf52b47 Instance ID : uuid:50ab3c40-180a-4ba1-9a88-5799fa7a02ba Producer : Acrobat Distiller 6.0 (Windows) Page Count : 5 Author : sullgr00EXIF Metadata provided by EXIF.tools