HARRIS TR-0017-E Sitepro Base Station User Manual RF Package

HARRIS CORPORATION Sitepro Base Station RF Package

RF Package

Download: HARRIS TR-0017-E Sitepro Base Station User Manual RF Package
Mirror Download [FCC.gov]HARRIS TR-0017-E Sitepro Base Station User Manual RF Package
Document ID311119
Application ID075vpy9BfOZpg8rQ7aTVIQ==
Document DescriptionRF Package
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.04kB (200479 bits)
Date Submitted2003-03-18 00:00:00
Date Available2003-03-07 00:00:00
Creation Date2002-02-27 13:54:21
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2003-03-03 17:55:46
Document TitleRF Package

Maintenance Manual
LBI-38754F
Preliminary
MASTR® III
RF Package, VHF
TABLE OF CONTENTS
TRANSMIT SYNTHESIZER
RECEIVE SYNTHESIZER .
RECEIVE RF MODULE . . .
IF MODULE . . . . . . . . .
LBI-38640
LBI-38641
LBI-38642
LBI-38643
LBI-39123
POWER AMPLIFIER . . . . . . . . . . . . . . LBI-38531
AE/LZB 119 3521/20
DUPLEXER . . . . . . . . . . . . . . . . . . . LBI-38763
M/A-COM Wireless Systems
3315 Old Forest Road
Lynchburg, Virginia 24501
(Outside USA, 434-385-2400) Toll Free 800-528-7711
www.macom-wireless.com
Printed in U.S.A.
LBI-38754G
SPECIFICATIONS
TABLE OF CONTENTS
Table 1 - Station Specifications
Page
ITEM
SPECIFICATION
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
REGULATORY APPROVALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
RECEIVER
MODULE NUMBERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SENSITIVITY (12 dB SINAD)
-116 dBm (0.35 µV)
ISOLATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ANTENNA SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SELECTIVITY (25 kHz)
(30 kHz)
-95 dB
-100 dB
INTERCONNECTION DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INTERMODULATION REJECTION
-90 dB
INTERMEDIATE FREQUENCY
21.4 MHz (low-side injection)
IMAGE REJECTION
-100 dB
SPURIOUS RESPONSE REJECTION
-100 dB
HUM & NOISE (300-3000 Hz)
-55 dB
AUDIO RESPONSE (de-emphasis)
+1/-3 dB of 6 dB/Octave (@ Line Output)
+2/-8 dB of 6 dB/Octave (@ Local Speaker)
When conducting repair/maintenance, disconnect the cabinet power supply plug from the AC source.
FREQUENCY SPREAD (range)
(full specification)
(3 dB degradation)
136.0-151 MHz, 150.8-174 MHz
2 MHz
3 MHz
In European applications, equipment must be installed in a closed cabinet.
TRANSMITTER
Only replace components with components specified by M/A-COM Private Radio Systems.
RATED POWER OUTPUT
110 Watts
FREQUENCY STABILITY
±1.5 ppm
CONDUCTED SPURIOUS EMISSIONS
-36 dBm
MODULATION DEVIATION
±5 kHz
FM HUM & NOISE (300-3000 Hz)
-55 dB
AUDIO RESPONSE (pre-emphasis)
+1/-3 dB of 6 dB/Octave
FREQUENCY SPREAD (range)
(full specification)
136.0-151 MHz, 150.8-174 MHz
136.0-151 MHz, 150.8-174 MHz
SAFETY NOTES
•
•
•
•
The means of disconnecting power from a station cabinet is the cabinet power supply plug.
NOTICE!
Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier. Any
repairs, alterations or substitution of recommended parts made by the user to this equipment not approved by the manufacturer
could void the user’s authority to operate the equipment in addition to the manufacturer’s warranty.
NOTICE!
The software contained in this device is copyrighted by the M/A-COM Private Radio Systems, Inc. Unpublished rights are
reserved under the copyright laws of the United States.
This manual is published by M/A-COM Private Radio Systems, Inc., without any warranty. Improvements and changes
to this manual necessitated by typographical errors, inaccuracies of current information, or improvements to programs
and/or equipment, may be made by M/A-COM Private Radio Systems, Inc., at any time and without notice. Such changes
will be incorporated into new editions of this manual. No part of this manual may be reproduced or transmitted in any
form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the
express written permission of M/A-COM Private Radio Systems, Inc.
Copyright© 1992 - 2002 M/A-COM Private Radio Systems, Inc. All rights reserved.
LBI-38754G
REGULATORY APPROVALS
The following equipment authorization numbers have been granted:
COUNTRY
REGULATORY APPROVAL
United States
FCC (Parts 15, 22, 74, 80, 90) AXATR-197-A2
Canada
DOC (RSS-119) TR-197
MODULE NUMBERS
TRANSMIT SYNTHESIZER . . . . . . . . . . . . . . . . . . . . . . . . . . 19D902780G1
RECEIVE SYNTHESIZER (150.8-174 MHz) . . . . . . . . . . . . . . . . 19D902781G1
(136.0-151 MHz) . . . . . . . . . . . . . . . . 19D902781G2
RX FRONT END MODULE (150.8-174 MHz) . . . . . . . . . . . . . . . . 19D902782G2
(136.0-151 MHz) . . . . . . . . . . . . . . . . 19D902782G1
IF MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19D902783G1
POWER AMPLIFIER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19D902797G1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19D902797G20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19D902797G21
LOW PASS FILTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19D902856G1
ANTENNA SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19B235897P1
ISOLATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344A3406P2
DUPLEXER (150-162 MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . 344A3371P1
DUPLEXER (162-174 MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . 344A3371P2
ACCESSORIES
Specifications
Frequency Range
Input Power
Short Circuit Duration
Insertion Loss
Isolation
LBI-38754G
Description
136-174 MHz (no tuning)
150 W (at max VSWR of 3.7:1)
100 ms max
0.3 dB max (25°C)
0.8 dB max (-40°C to +85°C)
18 dB min (25°C)
15 dB min (-40°C to +85°C)
The isolator has an internal load connected to an RF
detector (sensor), the output from the sensor is continually
monitored by the sttion for a fault conditon (high VSWR).
Once the station detects a sensor voltage above the threshold
the transmitter is automatically de-keyed and a FAULT condition is reported.
IMPORTANT:
The sensor output must be connected to
P108 on the Interface Board when the Isolator is used, failure to make this connection
with the Isolator installed will cause the
isolator to be damaged under high VSWR
conditions.
REFLECTED POWER
VSWR
TYPICAL
SENSOR VOLTAGE
10W
15W
20W
25W
30W
1.70:1
1.92:1
2.15:1
2.38:1
2.62:1
3.9V
4.8V
5.7V
6.4V
6.8V
WARNING
DO NOT USE ISOLATOR WITHOUT CONNECTING THE SENSOR TO THE STATION
ANTENNA SWITCH
ISOLATOR
19B235897P2
344A3406P1
LBI-38754G
MASTR III STATION
(19D903635 Sh. 1, Rev. 4)
INTERCONNECTION DIAGRAM
INTERCONNECTION DIAGRAM
LBI-38754G
MASTR III STATION
(19D903635, Sh. 2, Rev. 6)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2002:02:27 13:54:21
Producer                        : Acrobat Distiller 4.05 for Windows
Modify Date                     : 2003:03:03 17:55:46-07:00
Page Count                      : 6
Has XFA                         : No
Page Mode                       : UseThumbs
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OWDTR-0017-E

Navigation menu