Honeywell Analytics Asia Pacific RMBLEM5 Bluetooth Low Energy Module-RMBLE-M5 User Manual Host

Honeywell Analytics Asia Pacific Co., Ltd. Bluetooth Low Energy Module-RMBLE-M5 Host

Host user manual

Download: Honeywell Analytics Asia Pacific RMBLEM5 Bluetooth Low Energy Module-RMBLE-M5 User Manual Host
Mirror Download [FCC.gov]Honeywell Analytics Asia Pacific RMBLEM5 Bluetooth Low Energy Module-RMBLE-M5 User Manual Host
Document ID3190531
Application IDDercypZXluav8yxLDqZgJg==
Document DescriptionHost user manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize355.27kB (4440857 bits)
Date Submitted2016-11-08 00:00:00
Date Available2017-05-07 00:00:00
Creation Date2016-10-31 10:08:58
Producing SoftwareXeTeX 0.99996
Document Lastmod2016-11-04 15:20:12
Document TitleHost user manual
Document CreatorLaTeX with hyperref package
Document Author: hzguide.cls

Sensepoint XCL
Fixed Gas Detector
Installation Manual
2
About This Manual
This manual describes how to install the Sensepoint XCL gas detector.
This manual should be read by anyone who installs, operates, or maintains InCom gas detectors.
Read this manual before you install the product. Every effort has been
made to ensure the accuracy of this document. However, Honeywell can
assume no responsibility for any errors or omissions in this document or
their consequences. Honeywell would greatly appreciate being informed
of any errors or omissions that may be found in the content of this document. For information not covered in this document, or if there is a requirement to send comments or corrections about this document, please
contact Honeywell using the contact details given on the back page.
Honeywell reserves the right to change or revise the information supplied in this document without notice and without obligation to notify
any person or organization of such revision or change. If information is
required that does not appear in this document, contact the local distributor, agent, or Honeywell.
Contents
About This Manual
Contents
1 Introduction
1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Detectable Gases . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 Detector Connections . . . . . . . . . . . . . . . . . . . . . . . .
Analog (mA) Output Versions . . . . . . . . . . . . . . . . . . . .
Modbus Output Versions . . . . . . . . . . . . . . . . . . . . . .
1.5 Relay Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . 10
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Maximum Power Consumption . . . . . . . . . . . . . . . . . . 11
Operating Environment . . . . . . . . . . . . . . . . . . . . . . . 11
Wall-Mounting Screws . . . . . . . . . . . . . . . . . . . . . . . . 11
Cable Gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Gas Test Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 Installation
13
2.1 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
IC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2 Installation Layout . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3 Detector Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.4 Analog (mA) Output Versions . . . . . . . . . . . . . . . . . . . . 16
Power Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Inhibit Level Selection . . . . . . . . . . . . . . . . . . . . . . . . 16
Current Source/Sink Selection . . . . . . . . . . . . . . . . . . . 17
Contents
2.5 Modbus Output Versions . . . . . . . . . . . . . . . . . . . . . . 20
Modbus Connection . . . . . . . . . . . . . . . . . . . . . . . . . 20
Terminal Resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.6 Securing the Back Box to a Wall . . . . . . . . . . . . . . . . . . 21
2.7 Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.8 Ground Connections . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.9 Securing the Detector Module to the Back Box . . . . . . . . . 23
2.10 Remote Gassing Connection . . . . . . . . . . . . . . . . . . . . 25
3 Commissioning
26
3.1 External Status Indicator . . . . . . . . . . . . . . . . . . . . . . 26
3.2 Using the Setting Buttons . . . . . . . . . . . . . . . . . . . . . . 27
3.3 Internal Status Indicator . . . . . . . . . . . . . . . . . . . . . . . 27
4 Maintenance
30
4.1 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.2 Calibration Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.3 Bump Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4.4 Replacing the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . 34
5 Mobile App
36
A Warranty
37
B Safety Information for Wireless Devices
38
C Certification
39
D Contact Information
40
Chapter 1
Introduction
1.1
Features
Sensepoint XCL is a single sensor fixed gas detector, which supports the
following interfaces dependent on the model:
Analog output: Sensepoint XCL features current loop output, supporting signals in the range 0 to 22 mA.
Digital output: Sensepoint XCL supports Modbus RTU digital communications.
Relay output: Sensepoint XCL provides two change-over relays for signaling to external control systems or controlling external alarming
devices, for example audible and visual alarm indicators.
Mobile app: A mobile app is available to commission and maintain the
Sensepoint XCL gas detector.
Introduction
1.2
1.3
Appearance
1) Back box
2) Gas detector module
3) Sensor cover
5) Cable entries
4) Front cover
6) Visual indicator
7) Gas sensor
8) Dust protection membrane
Detectable Gases
Sensepoint XCL is available for the detection of the following gases:
• Oxygen (O2 )
• Toxic gases
– Ammonia (NH3 )
– Carbon dioxide (CO2 )
– Carbon monoxide (CO)
– Hydrogen (H2 )
– Hydrogen sulfide (H2 S)
– Nitrogen dioxide (NO2 )
• Combustible gases
Introduction
1.4
Detector Connections
The 4-way terminal block provides connection of both the gas detector
output and the power supply.
Analog (mA) Output Versions
1) +24 V DC or 24 V AC
2) 0 V or 24 V AC
3) 4 to 20 mA
4) Common
For details on wiring for analog output, see Analog (mA) Output Versions
on page 16 and Current Source/Sink Selection on page 17.
Modbus Output Versions
NOTE
Use of the mobile app is required to change the configuration settings
of the Modbus RTU interface.
1) +24 V DC or 24 V AC
2) 0 V or 24 V AC
3) A
4) B
Introduction
1.5
Relay Output
1) Relay No. 1
2) Relay No. 2
There are two configurable relays which can be used to control or signal
to external devices, such as audible and visual alarms and other control
systems.
Connection to these relays are made through the two three-way terminal
blocks.
1) Normally open (NO)
2) Common
3) Normally closed (NC)
Introduction
1.6
Specifications
Dimensions and Weight
113 mm
113 mm
59 mm
Length
113 mm
Depth
59 mm
Height
113 mm
Weight
500 g
DC input voltage
24 V DC1
AC input voltage
24 V AC2 , 50/60 Hz
Inrush current
Less than 850 mA
Power Supply
9 to 32 V DC
20 to 27 V AC
Sensepoint XCL requires an isolated power supply unit that is certified
by a national or international standard, such as UL.
Outputs
Analog output
0 to 22 mA sink or source (configurable)
Digital output
Modbus RTU
Relay output
Two configurable relays normally energised for
fault signalling and normally de-energised for
alarm signalling
10
Introduction
Maximum Power Consumption
The power consumption varies, depending on output mode and sensor
type. The total power consumption for two relay outputs is 0.6 W.
Analog Output Mode
In normal state
During an alarm
0.5 W
1.2 W
Catalytic-type sensors
1W
1.7 W
Infrared-type sensors
1W
1.7 W
In normal state
During an alarm
Electrochemical-cell-type sensors
0.2 W
0.7 W
Catalytic-type sensors
0.7 W
1.2 W
Infrared-type sensors
0.7 W
1.2 W
Electrochemical-cell-type sensors
Digital Output Mode
Operating Environment
Operating temperature
−20 to 50°C
Storage temperature
0 to 30°C
Humidity
0 to 100% (non-condensing)
Atmospheric pressure
90 to 110 kPa
Altitude
Lower than 2000 m
Installation category
II (UL/CSA/IEC/EN 61010-1)
Pollution degree
2 (UL/CSA/IEC/EN 61010-1)
NOTE
Sensepoint XCL is designed to be installed indoors only.
Wall-Mounting Screws
Thread diameter
4 mm
Length
longer than 25 mm
11
Introduction
Cable Gland
Inner knockout
M20 or ½ NPT
Outer knockout
M25 or ¾ NPT
Gas Test Tubing
For a bump test, use urethane tubing with one of the below specifications. See Remote Gassing Connection on page 25.
12
Inner diameter
Outer diameter
4 mm
6 mm
6 mm
8 mm
Chapter 2
Installation
2.1
Safety Information
CAUTION
Failure to observe the precautions described in this section can cause
injury to persons or damage to property.
Observe these precautions:
• To minimize the risk of electrostatic charge, provision shall be made
for adequate grounding and equipment shall be installed in such a
manner so that accidental discharge shall not occur.
• When Sensepoint XCL reaches the end of its life, it should be disposed
of in accordance with local regulations.
• Do not use cleaning solvents or abrasives to clean the gas detector.
Installation must be in accordance with the recognized standards of
the appropriate authority in the country concerned. For Europe, see
EN60079-14, EN60079-29-2, and EN61241-14. For installations in
North America, the National Electrical Code (NFPA 70) should be strictly
observed. Elsewhere the appropriate local or national regulations should
be used.
FCC Information
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions:
1) This device may not cause harmful interference.
13
Installation
2) This device must accept any interference received, including interference that may cause undesired operation.
This transmitter must not be co-located or operated in conjunction with
any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End
users must follow the specific operating instructions for satisfying RF exposure compliance.
NOTE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to pro-vide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
CAUTION
Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
IC Information
This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions:
1) This device may not cause interference.
2) This device must accept any interference, including interference that
may cause undesired operation of the device
Le present appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisee aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage;
(2) l’utilisateur de l’appareil doit accepter tout brouillage
radioelectrique subi, meme si le brouillage est susceptible d’en
compromettre le fonctionnement.
14
Installation
2.2
Installation Layout
1) A gas detection system using Modbus RTU. Detectors are wired in a
daisy chain on a single cable run.
2) A gas detector system using analog current loop principle. Each detector is individually wired to the controller on its own cable.
2.3
Detector Module
15
Installation
1) Inhibit switch
2) LED indicator
3) Up button
4) Down button
5) Current sink/source selection switch
6) Voltage output (negative)
7) Voltage output (positive)
2.4
Analog (mA) Output Versions
Power Connection
When connecting to DC power, make sure that the polarity is correct.
If an external power source is used, make sure that the fourth terminal is
properly grounded for analog output.
Inhibit Level Selection
Use the inhibit switch to determine what level of current is used in inhibit
mode.
16
Installation
1) With this switch in the outer position, a current of 4 mA is output in
inhibit mode. In the case of oxygen versions only, 17.4 mA is used.
2) With this switch in the inner position, a current of 2 mA is output in
inhibit mode on all versions.
Current Source/Sink Selection
Use the current source/sink switch to choose between source mode and
sink mode.
1) With this switch in the inner position, analog output works in sink
mode.
2) With this switch in the outer position, analog output works in source
mode.
Detector Source Mode with DC Power
VE+
VIN+
24 VDC
VE−
VIN−
RL
4–20mA
4–20mA
COM
1) System controller
2) Sensepoint XCL detector
3) Current flow
17
Installation
Detector Sink Mode with DC Power
VE+
VIN+
24 VDC
VE−
VIN−
RL
4–20mA
4–20mA
COM
1) System controller
2) Sensepoint XCL detector
3) Current flow
Detector Source Mode with AC Power
VE+
VIN+
24 VAC
VE−
VIN−
4–20mA
4–20mA
RL
COM
18
COM
1) External power supply
2) Sensepoint XCL detector
3) System controller
4) Current flow
Installation
Detector Sink Mode with AC Power
VE+
VIN+
24 VAC
VE−
4–20mA
24V
DC
VIN−
4–20mA
RL
COM
COM
1) External power supply
2) Sensepoint XCL detector
3) System controller
4) Current flow
19
Installation
2.5
Modbus Output Versions
Modbus Connection
For Modbus versions, up to 32 Sensepoint XCL detectors can be connected in a daisy chain arrangement as shown in the diagram below.
Terminal Resistor
Attach a 120 Ω, 0.25 W terminal resistor to D0 and D1 terminals at the
end of the line.
20
Installation
2.6
Securing the Back Box to a Wall
CAUTION
Before starting installation, make sure that the system controller or
external power source is not supplying power
1. There are four screw positions in the
rear of the back box for mounting purposes. Punch the required screw positions or drill using a 4 mm drill.
2. Secure the back box in its mounting
position with suitable fixings appropriate to the mounting surface. Do
not over-tighten.
3. There are four cable entry knock-outs
on three sides and rear face of the
back box. Drill or punch the entries as
required.
2.7
Cable Connections
1. Fit suitable cable glands to the
opened cable entries.
21
Installation
2. Feel the cable through the cable
gland.
3. Turn over the detector module and locate the terminal blocks on the back.
Remove the terminal blocks, pulling
them toward the center of the module.
4. Connect the cable to the appropriate
terminal block. Strip and insert the
end of each wire into the corresponding terminal hole, and tighten the terminal screw, using a flat-blade terminal screwdriver until the wire is secured.
CAUTION
Do not over-tighten the terminal
screw.
5. Replace the terminal blocks in their
correct positions.
22
Installation
2.8
Ground Connections
Effective grounding is crucial to ensure stable Modbus communications
and to limit the effects of radio frequency interference. Ground points
are provided inside the back box. In order to prevent false readings or
alarms as a result of ground loops, ensure that the shield of all cables
are grounded at a single point, preferably at the controller. Consideration
should also be given to how conduit, glands and the internal earth plate
are also grounded.
NOTE
Any earth regime must avoid earth loops.
2.9
Securing the Detector Module to the Back Box
NOTE
If the mobile Sensepoint XCL app is available, proceed to the next
stage to complete the installation, and then perform a calibration using the Sensepoint XCL app. Otherwise, perform a calibration before
securing the detector module to the back box. For details about how
to calibrate without the Sensepoint XCL app, see Calibration on page
30.
23
Installation
1. Remove the front cover from the detector module to expose the retaining
screws as follows:
a) Pull the flap on the bottom side to
open it.
b) To unlock the front cover, insert a
thin, straight tool, such as a small
screwdriver, into the hole beside
the tube spigot.
c) While applying slight pressure to
the tool, turn the cover counterclockwise until it stops, and then
lift it out.
2. Tighten the retaining screws using a
number-2 phillips screwdriver to secure the detector module to the back
box.
CAUTION
Do not over-tighten the screws.
3. Where appropriate, tighten the sealing nut of the cable gland to secure
the cable.
4. Replace the front cover.
Place the
front cover into the detector module
with the logo at a 45 degree angle as
shown and rotate it clockwise until it
locks into position.
24
Installation
2.10
Remote Gassing Connection
If the gas detector is installed in an inaccessible location, such as overhead on a ceiling, connect a tube to the gas detector for bump test or
calibration.
• For a temporary connection, open the flap on the bottom side and
connect suitable tubing compatible with the gas type of the sensor
to the tube spigot.
• For a permanent connection, remove the flap, connect the tube connector to the spigot, and then connect a tube to the tube connector.
Secure the tube using a cable tie or small jubilee clip, taking care not
to over-tighten it.
25
Chapter 3
Commissioning
3.1
External Status Indicator
There is one visual indicator on the face of the gas detector. It turns on
solid or flashes in four different colors to show the operating status.
Normal: The indicator is lit solid green when the concentration of the
target gas is within normal range.
NOTE
Using the mobile Sensepoint XCL app, you can change how the
green indicator behaves during normal operation, for example,
like slow intermittent flashing or staying off.
Warning: It flashes green when the gas detector is in a warning state.
Fault: It flashes yellow when the gas detector is in a fault state.
Inhibited: It is on solid yellow when the user has placed the detector
into the inhibit state for maintenance or repair.
Alarm: It rapidly flashes red when the gas concentration is beyond
the high-level threshold.
Out-of-range alarm: It flashes red with short and long pauses when
the gas concentration is outside of the normal range.
26
Commissioning
Bluetooth pairing: It flashes blue when Bluetooth pairing between
the gas detector and an Android device is in progress.
Bluetooth connected: It is on solid blue when a Bluetooth connection is established.
3.2
Using the Setting Buttons
When the mobile Sensepoint XCL app is not available, the setting buttons
allow you to perform a calibration or bump test. Be familiar with how to
use the setting buttons.
Switch from monitor mode to inhibit mode. Press and hold the up and
down buttons simultaneously for 2 seconds.
NOTE
Make sure that the inhibit level is set to the desired level. See Inhibit
Level Selection on page 16.
Increase the output voltage. Briefly press the up button. Pressing once
increases by 0.01 V. To go up by 0.1 V, press and hold the button.
Decrease the output voltage. Briefly press the down button. Pressing
once decreases by 0.01 V. To go down by 0.1 V, press and hold the button.
Move to the next stage. Press and hold the up and down buttons simultaneously for 2 seconds. If a change has been made, it is saved before
proceeding to the next stage.
At any stage, exit to monitor mode without saving any changes made.
Press and hold both buttons simultaneously for 5 seconds.
3.3
Internal Status Indicator
There are two indicators on the rear of the detector module. When doing
maintenance, such as calibration or sensor replacement, using the set-
27
Commissioning
ting buttons, refer to those indicators to see what the detector’s status
is.
1) This RGB indicator behaves differently according to the detector’s
status.
2) This yellow indicator stays on while in inhibit mode.
Inhibit mode
While in inhibit mode, the yellow indicator stays on
Sensor replacement mode
While in sensor replacement mode, the yellow indicator stays on, and the
RGB indicator slowly flashes red
tor flashes yellow
. When in warm-up, the RGB indica-
Zero calibration
At zero calibration, the RGB indicator flashes yellow
tor flashes green
. The RGB indica-
if the zero calibration succeeds, but flashes red
if it fails.
Span calibration
At span calibration, the RGB indicator flashes yellow
cator flashes green
. The RGB indi-
with two short pauses if the zero calibration suc-
ceeds, but flashes red
with two short pauses if it fails.
Calibration gas purge
While the calibration gas is purged, the RGB indicator flashes yellow
28
Commissioning
Cancel
When a task is canceled, the RGB indicator flashes yellow
with three
short pauses.
29
Chapter 4
Maintenance
4.1
Calibration
This section describes how to perform a calibration using the setting buttons. Before starting calibration, make sure that the gas detector is powered on.
1. Activate inhibit mode. Make sure that the LED indicator is solid yellow.
2. Put the positive probe of a voltmeter on the positive terminal, and the
negative probe on the negative terminal.
3. Proceed to the next stage to calibrate the zero point.
a) If there is any doubt of gas being present in the atmosphere, connect a cylinder of fresh air to the detector using the installed tube
or the calibration cap. For details about how to use a calibration
cap, see Calibration Cap on page 31.
b) Apply fresh air to the detector, and wait for a few minutes until the
reading is stable.
c) Adjust the output voltage so that the DVM is reading slightly
above zero, and then decrease the reading slowly so that it reads
zero.
4. Calibrate the span.
30
Maintenance
a) Connect a cylinder of span gas to the detector. The cylinder concentration should be approximately 50% of the range of the detector.
b) Apply the span gas to the detector, and wait for a few minutes until
the reading is stable.
c) Adjust the output voltage until it reaches the target value. Use the
formula below to calculate what the correct voltage should be.
Vout = Gas concentration ÷ detector range
For example, if you are applying 45% LEL gas with a 100% LEL
detector range, you would need to adjust the voltage output so
that the reading on the DVM shows:
45 ÷ 100 = 0.45 V
5. Purge the gas sensor.
a) Remove the span gas from the detector.
b) Make sure that the reading voltage out returns to zero. If there is
any doubt that the detector is not in fresh air, apply cylinder air.
Otherwise, a false alarm may occur.
6. Exit to monitor mode.
If repeated calibration attempts continue to fail, replace the gas sensor
with a new one, and then try again. See Replacing the Sensor on page
34.
4.2
Calibration Cap
If the detector has no tube installed, a calibration cap for Sensepoint XCL,
which is sold separately, is required to do a calibration. Use this method
to apply a reference gas to the detector using a calibration cap.
31
Maintenance
1. Remove the front cover.
a) Pull the flap on the bottom side to
open it.
b) Insert a thin, straight tool, such as
a paper clip, into the hole beside
the tube spigot.
c) While applying slight pressure to
the tool, turn the cover counterclockwise until it stops, and then
pull it out.
2. Attach the calibration cap to the detector. Insert the calibration cap into
the front of the detector as shown,
and turn it clockwise until it locks into
place.
3. Connect a tube from a cylinder of calibration gas to either of the cap’s spigots.
4. Connect another tube to the other
spigot, and put the other end of the
tube to ventilate away from the work
area.
32
Maintenance
5. To start a gas flow, turn the regulator
knob counterclockwise.
6. To stop the gas flow, turn the regulator knob clockwise.
CAUTION
Always use a gas cylinder that is within its expiry date.
4.3
Bump Test
This section describes how to perform a bump test using the Sensepoint
XCL mobile app. For details about the mobile app, see Replacing the
Sensor on page 36.
Bump testing is the process of briefly exposing the gas sensor to a known
concentration of reference gas that is greater than the low alarm threshold. This is the only way to verify the proper operation of the gas detector.
1. Connect a cylinder of reference gas to the target detector using the
installed tube or the calibration cap. For details about how to use a
calibration cap, see Calibration Cap on page 31.
2. Connect your smartphone with the target detector via Bluetooth.
NOTE
For carbon monoxide (CO) versions, make sure that the detector
is in UL 2075 alarm mode.
3. Activate the detector’s inhibit mode.
4. Apply the reference gas to the detector.
NOTE
For CO versions, apply 300 ml of 100 ppm carbon monoxide for 3
minutes.
5. If the detector fails the bump test, calibrate the detector.
33
Maintenance
NOTE
For CO versions, perform bump test twice a year.
4.4
Replacing the Sensor
NOTE
The operating lifetime of the CO sensor is 6 years.
If the mobile Sensepoint XCL app is not available, make sure that power
is removed before replacing the gas sensor.
1. Press and hold both buttons simultaneously for 10 seconds to switch
to sensor replacement mode. In this
mode, the detector output is inhibited
and the sensor is disconnected from
power.
2. Remove the front cover to expose the
sensor cover.
a) Pull the flap on the bottom side to
open it.
b) To unlock the front cover, insert a
thin, straight tool, such as a small
screwdriver, into the hole beside
the tube spigot.
c) While applying slight pressure to
the tool, turn the cover counterclockwise until it stops, and then
pull it out.
3. Remove the sensor cover.
a) Loosen the screw on the upper
part of the sensor cover.
b) Holding the screw, tilt it downwards from the upper edge of the
cover.
34
Maintenance
4. Pull out the gas sensor to remove it.
CAUTION
Do not force the sensor into the
socket, otherwise it may be damaged.
5. Ensuring that the sensor pins are correctly aligned, insert a new sensor
into the sensor socket.
6. Press and hold both buttons simultaneously for 3 seconds to activate
warm-up mode. In this mode, the output continues to be held in its inhibit
state.
7. Connect a cylinder of reference gas to
the detector using the installed tube
or a calibration cap.
8. Apply a reference gas to the detector, and measure the output voltage
to see if the reading is stable and the
correct value according to this formula.
Vout = Gas concentration ÷ detector
range
9. Switch to monitor mode.
10. Replace the sensor cover.
35
Chapter 5
Mobile App
A dedicated mobile app for Sensepoint XCL is available. The mobile app
makes it much easier to monitor and maintain Sensepoint XCL detectors.
The general procedure of using the mobile app is as follows:
1. Download the Sensepoint XCL app from Google Play, and launch the
app.
2. Create an administrator account.
3. To associate with an installed detector, scan the QR code on the sheet
included in the box.
4. Tap DETECTORS from the app home screen to scan for available gas
detectors.
5. Select a gas detector from the detector list to pair with it.
6. Look for the detector whose LED indicator is flashing blue.
7. Tap Confirm Detector to pair with that detector. Otherwise, tap Return to list to select one of the others.
When a Bluetooth connection is established, the detector’s reading is
displayed on the app interface with the gas type. For details how to use
the mobile app, refer to the Sensepoint XCL app manual.
NOTE
For carbon monoxide (CO) versions, use the Sensepoint XCL mobile
app to change the alarm mode setting to UL 2075.
36
Appendix A
Warranty
Honeywell Analytics warrants the Sensepoint XCL gas detector against
defective parts and workmanship.
This warranty does not cover consumable, batteries, fuses, normal wear
and tear, or damage caused by accident, abuse, improper installation,
unauthorized use, modification or repair, ambient environment, poisons,
contaminants or abnormal operating conditions.
This warranty does not apply to sensors or components that are covered
under separate warranties, or to any 3rd-party cables and components.
In no event shall Honeywell Analytics be liable for any damages or injury
of any nature or kind, no matter how caused, that arise from incorrect
handling or use of this equipment.
In no event shall Honeywell Analytics be liable for any equipment malfunction or damages whatsoever, including (without limitation) incidental, direct, indirect, special, and consequential damages, damages for
loss of business profits, business interruption, loss of business information, or other pecuniary loss, resulting from the incorrect installation or
use of this equipment.
Any claim under the Honeywell Analytics Product Warranty must be
made within the warranty period and as soon as reasonably practicable
after a defect is discovered. Please contact your local Honeywell Analytics Service representative to register your claim.
This is a summary. For full warranty terms please refer to the Honeywell Analytics’ General Statement of Limited Product Warranty, which is
available on request.
37
Appendix B
Safety Information for Wireless Devices
FCC Compliance
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CAUTION
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the device.
RF Exposure Information
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This device has very low levels of RF energy that it
is deemed to comply without maximum permissive exposure evaluation
(MPE). But it is desirable that it should be installed and operated keeping
the radiator at least 20 cm or more away from person’s body.
38
Appendix C
Certification
Electrical Safety
• UL 61010-1
• CSA C22.2 No. 61010-1
• IEC/EN 61010-1
Electromagnetic Compatibility
• EN 50270:2015
Radio
• R&TTE
• FCC / IC
Contains FCC ID: 2AISERMBLEM5
Contains IC ID: 21613-RMBLEM5 (HMN: Sensepoint XCL)
• BT SIG
Enclosure Protection
• IP55
• NEMA Type 4
Gas Performance
• UL 2075 (CH4 and CO)
39
Appendix D
Contact Information
For more contact information, visit www.honeywellanalytics.com.
Americas
Honeywell Analytics Inc.
405 Barclay Blvd. Lincolnshire, IL 60069, USA
Toll-free: +1 800 538 0363
Alternative: +1 847 955 8200
Fax: +1 847 955 8210
detectgas@honeywell.com
www.honeywell.com
Asia Pacific (AP)
Honeywell Analytics Asia Pacific
7F Sangam IT Tower, 434 World Cup buk-ro, Mapo-gu, Seoul 03922, Korea
Tel: +82 (0)2 6909 0300
Fax: +82 (0)2 2025 0328
India Tel: +91 124 4752700
analytics.ap@honeywell.com
Europe, Middle East, Africa (EMEA)
Life Safety Distribution AG
Javastrasse 2, 8604 Hegnau, Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
40
Contact Information
Customer service
Freephone: 00800 333 222 44
Alternative: +41 44 943 4380
Fax: 00800 333 222 55
Middle East Tel: +971 4 450 5800 (Fixed gas detection)
Middle East Tel: +971 4 450 5852 (Portable gas detection)
Technical service
USA: ha.us.service@honeywell.com
AP: ha.ap.service@honeywell.com
EMEA: HAexpert@honeywell.com
41
Keep this manual for later use.
2108M0550_Issue_1
© 2016 Honeywell Analytics

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : hzguide.cls
Create Date                     : 2016:10:31 10:08:58+09:00
Modify Date                     : 2016:11:04 15:20:12+09:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.158975, 2016/02/13-02:40:29
Format                          : application/pdf
Creator                         : hzguide.cls
Creator Tool                    : LaTeX with hyperref package
Metadata Date                   : 2016:11:04 15:20:12+09:00
Producer                        : XeTeX 0.99996
Document ID                     : uuid:b7c35088-3531-47bf-bd40-f32abf0aaff3
Instance ID                     : uuid:99923293-32cd-40d5-84d6-ad80b38b0c01
Page Mode                       : UseOutlines
Page Count                      : 42
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AISERMBLEM5

Navigation menu